WorldWideScience

Sample records for opaque porcelain applied

  1. [Effects of different surface conditioning agents on the bond strength of resin-opaque porcelain composite].

    Science.gov (United States)

    Liu, Wenjia; Fu, Jing; Liao, Shuang; Su, Naichuan; Wang, Hang; Liao, Yunmao

    2014-04-01

    The objective of this research is to evaluate the effects of different silane coupling agents on the bond strength between Ceramco3 opaque porcelain and indirect composite resin. Five groups of Co-Cr metal alloy substrates were fabricated according to manufacturer's instruction. The surface of metal alloy with a layer of dental opaque porcelain was heated by fire. After the surface of opaque porcelain was etched, five different surface treatments, i.e. RelyX Ceramic Primer (RCP), Porcelain Bond Activator and SE Bond Primer (mixed with a proportion of 1:1) (PBA), Shofu Porcelain Primer (SPP), SE bond primer (SEP), and no primer treatment (as a control group), were used to combine P60 and opaque porcelain along with resin cement. Shear bond strength of specimens was tested in a universal testing machine. The failure modes of specimens in all groups were observed and classified into four types. Selected specimens were subjected to scanning electron microscope and energy disperse spectroscopy to reveal the relief of the fracture surface and to confirm the failure mode of different types. The experimental results showed that the values of the tested items in all the tested groups were higher than that in the control group. Group PBA exhibited the highest value [(37.52 +/- 2.14) MPa] and this suggested a fact that all of the specimens in group PBA revealed combined failures (failure occurred in metal-porcelain combined surface and within opaque porcelain). Group SPP and RCP showed higher values than SEP (P porcelain or composite resin) while all the specimens in group SEP and control group revealed adhesive failures. Conclusions could be drawn that silane coupling agents could reinforce the bond strength of dental composite resin to metal-opaque porcelain substrate. The bond strength between dental composite resin and dental opaque porcelain could meet the clinical requirements.

  2. Effect of Thickness and Brand of Metal Ceramic Porcelain on Color

    Science.gov (United States)

    1991-05-01

    Jelenko and Company, Penwalt Corp., Armonk, NY) and one metal ceramic porcelain without shade matched opaques (Vita VMK 68, Vident , Baldwin Park, CA...facial tissue, and smoothed with a dry brush (Plate 11). Vita opaque was mixed with Paint-On Liquid ( Vident , CA) and Vita dentin porcelain was mixed...with Vita Modelling Liquid ( Vident , CA). Ceramco opaque porcelain was mixed with Opaque Liquid (Dentsply International Inc., PA) and the Ceramco

  3. Stress relaxation behavior of dental porcelains at high temperatures.

    Science.gov (United States)

    DeHoff, P H; Vontivillu, S B; Wang, Z; Anusavice, K J

    1994-05-01

    The purpose of this study was to measure the stress relaxation behavior at elevated temperatures of three experimental opaque porcelains and three experimental body porcelains. Feldspathic porcelain formulations covering a range of thermal contraction coefficients were supplied by a dental ceramics manufacturer. Six specimens, 11 mm in diameter by 22 mm long, were fabricated for each porcelain. The specimens were tested in compression at five temperatures controlled to +/- 1 degree C in a hot stage furnace attached to a screw-type uni-axial testing machine. Mean values of relaxation time, tau u, and the b function were determined by a regression fit to the relation: psi (t) = exp [-(t/tau u)b]. Values of b ranged from 0.23 to 0.53 for opaque porcelain and 0.47 to 0.64 for body porcelain. Relaxation times ranged from 2.6 s to 4 x 10(4) s for the opaque porcelains and 1.5 s to 5.5 x 10(2) s for the body porcelains. A statistically significant variation of b with temperature for three of the experimental porcelains is an indication that these porcelains do not satisfy the theoretical requirements for the porcelains to be classified as thermorheologically simple. A knowledge of the relaxation behavior of dental porcelains is necessary so that dental researchers can identify metal/porcelain combinations that will result in low stress values and, therefore, reduce the potential for failure from thermally induced stresses. These properties can be used in the optimization of prosthesis design to reduce the destruction of healthy tissue to accommodate the placement of the dental prosthesis.

  4. Analysis of tempering stresses in bilayered porcelain discs.

    Science.gov (United States)

    DeHoff, P H; Anusavice, K J

    1992-05-01

    Previous studies of opaque-porcelain/body-porcelain discs have shown that compressive stresses which develop in the porcelain surface by being tempered in air can inhibit the sizes of cracks induced within the surface. The objective of this study was to develop a theoretical model for analysis of transient and residual stresses in opaque-porcelain/body-porcelain discs which were produced under variable cooling conditions. The model incorporates the effects of stress and structural relaxation. Transient and residual stresses were calculated for bilayered porcelain discs 16 mm in diameter and 2 mm in thickness for three opaque-porcelain/body-porcelain combinations. Transient temperature distributions in the discs for simulated convective cooling were calculated by finite-element analysis. Data from microhardness indentations reported by Anusavice et al. (1989) indicate that crack lengths measured for bilayered porcelain discs subjected to slow cooling conditions, for which the model predicted residual tensile stresses, were greater than those combinations for which residual compressive stresses were calculated. Calculated values of residual compressive stress for tempered specimens were considerably higher than those for specimens that were slowly cooled and those that were cooled by free convection. In general, residual stress levels calculated by use of the analytical model were in fairly good agreement with the trends observed for crack lengths and bi-axial flexural strengths reported by Anusavice and Hojjatie (1991). The results of the present study indicate that a visco-elastic model is a viable approach for determination of transient and residual stresses in opaque-porcelain/body-porcelain discs.

  5. Porcelain Gallbladder

    Science.gov (United States)

    Machado, Norman O.

    2016-01-01

    Gallbladder calcification, also referred to as porcelain gallbladder, has received significant attention in the medical literature due to its perceived role in increasing the risk of developing a gallbladder carcinoma. However, recent reports raise questions challenging this purported high risk. While previous studies reported a concomitant incidence of gallbladder cancer in porcelain gallbladder ranging from 7–60%, more recent analyses indicate the incidence to be much lower (6%). Based on evidence in the current literature, a prophylactic cholecystectomy is not routinely recommended for all patients with porcelain gallbladder and should be restricted to those with conventional indications, such as young patients. However, it is important to note that a nonoperative approach may require prolonged follow-up. A laparoscopic cholecystectomy is a feasible therapeutic option for patients with porcelain gallbladder, although some researchers have indicated a higher incidence of complications and conversion due to technical difficulties. PMID:28003886

  6. Special enamels for porcelained stoneware substrates

    Directory of Open Access Journals (Sweden)

    Tichell, M. T.

    2000-02-01

    Full Text Available In the present work, a ceramic glaze compatible with the porcelained stoneware body and presenting a good glaze-body adaptability, has been obtained. Taking into account its industrial applicability, we have started from industrial raw materials, formulating compositions of transparent and opaque frits so as to, once applied on porcelained stoneware bodies, and in a monofiring process, have zircon and calcium aluminate crystallizations devitrify. The materials developed have been structurally and microstructurally characterized. To finish, the quality parameters have been determined, and the introduction of pigments has been designed, always bearing in mind the control of their stability.

    A través del presente trabajo, se ha obtenido un esmalte cerámico compatible con la pasta del gres porcelánico y que presenta buena adaptabilidad esmalte-soporte. Dada la orientación de su aplicabilidad industrial, se ha partido de materias primas industriales, formulando composiciones de fritas transparentes y opacas para que una vez aplicados sobre soportes de gres porcelánico y en un proceso de monococción, desvitrifiquen cristalizaciones de silicato de circonio y aluminato de calcio. Los materiales desarrollados se han caracterizado estructural y microestructuralmente. Por último, se han determinado los parámetros de calidad y se ha diseñado la introducción de pigmentos bajo el punto de vista del control de estabilidad de los mismos.

  7. In Pursuit of Porcelain

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Chinese contemporary porcelain art has great investment potentialfor ordinary collectorsAntique porcelain artifacts have longdominated the porcelain collectionmarket, but the recent emergence ofincreasing numbers of counterfeitworks and exorbitant prices are pushingcollectors in a new direction. Enter contem-porary porcelain artworks that experts sayhave a huge potential and less danger ofbeing fake copies.

  8. Prosperity in Porcelain

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Exports of porcelain in ancient China helped boost the world trade and spread Chinese culture Porcelain is generally believed to have originated in China,the reason it is also called "china" in the West.

  9. Effects of dental porcelain containing silver nanoparticles on static fatigue.

    Science.gov (United States)

    Fujieda, Tokushi; Uno, Mitsunori; Ishigami, Hajime; Kurachi, Masakazu; Kamemizu, Hideo; Wakamatsu, Nobukazu; Doi, Yutaka

    2013-01-01

    The purpose of this study was to clarify the effect of silver nanoparticles on the behavior of subcritical crack growth (SCG) in dental porcelains. Prior to occurrence of fast fracture in dental porcelains, SCG occurs and leads to strength degradation over time. SCG in dental porcelains can be characterized by the stress corrosion susceptibility coefficient, n. A higher n value means a higher resistance to SCG. In this study, porcelain disks were prepared by mixing a commercial dental porcelain powder with different concentrations of silver nanoparticles, and then air-dried and fired according to manufacturer's instructions. Stress corrosion susceptibility coefficients of powder compacts were determined using a post-indentation method. A Vickers indenter was applied to the porcelain surface, and lengths of median cracks were measured at fixed time intervals over a 24-h period to calculate n. Addition of silver nanoparticles significantly increased the stress corrosion susceptibility coefficient of dental porcelain.

  10. Multinationality and Opaqueness

    DEFF Research Database (Denmark)

    Aabo, Tom; Pantzalis, Christos; Park, Jung Chul

    2015-01-01

    We investigate whether and how multinationality affects the opaqueness of the firm. We use multiple alternative measurements of multinationality and opaqueness. Spanning nearly three decades for a large sample of US non-financial firms, we find a statistically and economically significant, positive...

  11. Evaluation of an experimental dental porcelain.

    Science.gov (United States)

    Hamouda, Ibrahim M; El-Waseffy, Noha A; Hasan, Ahmed M; El-Falal, Abeer A

    2010-11-01

    The aim of this study was to evaluate fracture toughness, hardness, ceramic/metal bond strength and microstructure of experimental dental porcelain and compare it with commercial type. Specimens of specific dimensions were prepared. Fracture toughness was assessed by a three-point bending test. The Vickers hardness was measured using a microhardness tester. The ceramometal bond strength was measured using a universal testing machine. The load was applied at the porcelain/metal interface via a chisel edged blade with a crosshead speed of 2.0 mm/min until fracture. The polished specimens of dental porcelain were chemically etched and the microstructure was analyzed with a scanning electron microscope. The results showed comparable fracture toughness and bond strength for both materials, while the experimental porcelain exhibited higher hardness. The experimental porcelain showed uniform cohesive failure while the commercial type showed mixed mode of failure. The microstructure of the experimental porcelain was tetragonal leucite crystals dispersed randomly in a glass matrix. The leucite crystals exist in two forms, acicular and rod like structures. It was concluded that the experimental porcelain has adequate fracture toughness and ceramic/metal bond strength that can resist the rapid crack propagation and its consequent catastrophic failure, which indicates a material serviceability in the oral cavity.

  12. Effect of three porcelain etchants type (HF-APF-PHA on porcelain- composite shear bond strength

    Directory of Open Access Journals (Sweden)

    Kermanshah H.

    2005-05-01

    Full Text Available Statement of Problem: Porcelain restorations are susceptible to fracture and a common method for repairing is the use of silane and composite on etched porcelain. Although HF is very effective in porcelain etching but has detrimental effects on tissues. Purpose: In this study, the effect of APF and PHA was compared with HF in porcelain etching. Also the role of silane, unfilled resin and dentin bonding in bond strength of composite- porcelain was evaluated. Methods and Materials: In this experimental in-vitro study, one-hundred twenty porcelain square blocks (552 mm were prepared and bonding surfaces of each sandblasted. Samples were divided into three groups. The first group (n=40 were etched with buffered HF 9.5% (Ultradent for 1 min., the second group (n=40 were etched with Iranian APF 1.23% (Kimia for 10 minutes and the third group (n=40 were etched with Iranian PHA 37% (Kimia for 1 min. Ultradent silane was applied on the surfaces of half of cases in each group. On the surfaces of half of silane-treated samples unfilled resin was applied and dentin bonding was used on the surfaces of the remaining. Samples without silane were treated in a similar manner. Composite cylinder with 4mm diameter and 2 mm height was bonded to porcelain. Specimens were stored in 37°C distilled water for 24 hours and subjected to 500 cycles. Shear bond strength was measured with an Instron machine and type of fracture was evaluated using a stereomicroscope. Results were analyzed using 3 way ANOVA, Kaplan- Maier and Tukey HSD tests. Results: Findings showed that PHA and APF roughened the porcelain surface without creating retentive micro undercuts but HF etches porcelain and creates retentive microundercuts. Ultradent silane had no significant effect on bond strength of porcelain- composite. Unfilled resin with Ultradent silane compared with dentin bonding with the same silane is more effective in bond strength of composite- porcelain. Conclusion: Based on

  13. Shear bond strength of veneering porcelain to porous zirconia.

    Science.gov (United States)

    Nakamura, Takashi; Sugano, Tsuyoshi; Usami, Hirofumi; Wakabayashi, Kazumichi; Ohnishi, Hiroshi; Sekino, Tohru; Yatani, Hirofumi

    2014-01-01

    In this study, two types of porous zirconia and dense zirconia were used. The flexural strength of non-layered zirconia specimens and those of the layered zirconia specimens with veneering porcelain were examined. Furthermore, the shear bond strength of veneering porcelain to zirconia was examined. The flexural strength of the non-layered specimens was 1,220 MPa for dense zirconia and 220 to 306 MPa for porous zirconia. The flexural strength of the layered specimens was 360 MPa for dense zirconia and 132 to 156 MPa for porous zirconia, when a load was applied to the porcelain side. The shear bond strength of porcelain veneered to dense zirconia was 27.4 MPa and that of porcelain veneered to porous zirconia was 33.6 to 35.1 MPa. This suggests that the veneering porcelain bonded strongly to porous zirconia although porous zirconia has a lower flexural strength than dense zirconia.

  14. Playing Children Adorn Ancient Porcelain

    Institute of Scientific and Technical Information of China (English)

    1995-01-01

    Porcelain is one of China’s greatest achievernents. It appeared during the Eastern Han Dynasty (25-220) and developed into three types of blue porcelain, white porcelain and colored porcelain between the Tang and Song dynasties. From the time of the Ming Dynasty (1368-1644), porcelain-making evolved, glazes and colors improved and porcelain was sold overseas. The quaint shapes and colorfully deslgned porcelain of the Ming Dynasty showed the appeal of folklife, but it was mainly used in the palace. Shown here are some pieces decorated with children at play. From these artifacts we can get an idea of the hairstyles, dress and architecture of that time.

  15. Opaqueness and Bank Risk Taking

    Directory of Open Access Journals (Sweden)

    Patrick Behr

    2012-12-01

    Full Text Available This paper investigates the relationship between opaqueness and bank risk taking. Using a sample of 199 banks from 38 countries over the period January 1996 to December 2006, I analyze whether more opaque banks are riskier than less opaque banks. I find suggestive evidence that commonly used proxies for bank opaqueness are significantly related to bank risk taking as measured by the Merton PD and the bank-individual Z-score, even after accounting for potential simultaneity between risk taking and opaqueness. More opaque banks seem to engage more in risk taking than less opaque banks. This result provides support to the common view that bank opaqueness is problematic and that transparency among financial institutions should be increased.

  16. PIXE analysis of ancient Chinese Changsha porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Lin, E.K.; Yu, Y.C.; Wang, C.W.; Liu, T.Y.; Wu, C.M.; Chen, K.M.; Lin, S.S

    1999-04-02

    In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed.

  17. The opaque square

    OpenAIRE

    2013-01-01

    The problem of finding small sets that block every line passing through a unit square was first considered by Mazurkiewicz in 1916. We call such a set {\\em opaque} or a {\\em barrier} for the square. The shortest known barrier has length $\\sqrt{2}+ \\frac{\\sqrt{6}}{2}= 2.6389\\ldots$. The current best lower bound for the length of a (not necessarily connected) barrier is $2$, as established by Jones about 50 years ago. No better lower bound is known even if the barrier is restricted to lie in th...

  18. Opaque cloud detection

    Science.gov (United States)

    Roskovensky, John K [Albuquerque, NM

    2009-01-20

    A method of detecting clouds in a digital image comprising, for an area of the digital image, determining a reflectance value in at least three discrete electromagnetic spectrum bands, computing a first ratio of one reflectance value minus another reflectance value and the same two values added together, computing a second ratio of one reflectance value and another reflectance value, choosing one of the reflectance values, and concluding that an opaque cloud exists in the area if the results of each of the two computing steps and the choosing step fall within three corresponding predetermined ranges.

  19. Adhesion to porcelain and metal.

    Science.gov (United States)

    Bertolotti, Raymond L

    2007-04-01

    Some compelling clinical benefits of porcelain and metal adhesion are presented. Current concepts for metal adhesion are reviewed, including modifications of metal surface and resin chemistry. Porcelain adhesion is reviewed, including little-known methods that use silane but no hydrofluoric acid etching. Clinical protocols for use of metal and porcelain adhesives are presented.

  20. Low absorptance porcelain-on-aluminum coating

    Science.gov (United States)

    Leggett, H.

    1979-01-01

    Porcelain thermal-control coating for aluminum sheet and foil has solar absorptance of 0.22. Specially formulated coating absorptance is highly stable, changing only 0.03 after 1,000 hours of exposure to simulated sunlight and can be applied by standard commercial methods.

  1. The minimum thickness of a multilayer porcelain restoration required for masking severe tooth discoloration

    Science.gov (United States)

    Shadman, Niloofar; Kandi, Saeideh Gorji; Ebrahimi, Shahram Farzin; Shoul, Maryam Azizi

    2015-01-01

    Background: Although studies have shown that porcelain veneers are very efficient for treating discolored teeth, they did not address in particular the minimum thickness of a multilayer IPS e.max Press (IvoclarVivadent, Schaan, Liechtenstein) restoration required to mask discolored tooth. The aim of this study was to determine the minimum thickness of a multilayer porcelain restoration required for masking severe tooth discoloration. Materials and Methods: A total of 24 disk-shaped multilayer specimens were prepared from IPS e.max Press with the diameter of 13 mm and four different thicknesses (core/veneer: 0.4/0.4 mm, 0.5/0.5 mm, 0.6/0.6 mm and 0.8/0.7 mm). Two backgrounds, C4-shade body porcelain and an opaque background from the selected IPS e.max ceramic itself were fabricated to mimic a discolored or stained natural tooth structure and to determine the masking ability. After applying the resin cement layer (Panavia F2.0) with 0.01 mm thickness on each background, all specimens were measured on both background using a spectrophotometer and values of L*, a* and b* were calculated to determine the color differences (ΔE*ab). One-way ANOVA and post-hoc tests of specimen average one-to-one comparison (Tukey HSD) were conducted and P ≤ 0.05 was set as the level of significance. Results: ΔE*ab of all groups were within the range of the clinically acceptable color difference (ΔE≤3.3), thus all the groups could mask the C4 background even group 1 with only 0.8 mm thickness. A trend was shown in the results as by increasing the thickness, ΔE*ab is was decreased. The mean ΔE*1*a*b between different thicknesses were statistically significant (P < 0.05) only between group 4 with groups 1 and 2, respectively. Conclusion: Within the limitations of this study, all studied thicknesses could mask the C4 background. However, the minimum thickness of a multilayer porcelain restoration (IPS e.max Press) required for masking severe tooth discoloration was 0.8 mm. PMID

  2. The minimum thickness of a multilayer porcelain restoration required for masking severe tooth discoloration

    Directory of Open Access Journals (Sweden)

    Niloofar Shadman

    2015-01-01

    Full Text Available Background: Although studies have shown that porcelain veneers are very efficient for treating discolored teeth, they did not address in particular the minimum thickness of a multilayer IPS e.max Press (IvoclarVivadent, Schaan, Liechtenstein restoration required to mask discolored tooth. The aim of this study was to determine the minimum thickness of a multilayer porcelain restoration required for masking severe tooth discoloration. Materials and Methods: A total of 24 disk-shaped multilayer specimens were prepared from IPS e.max Press with the diameter of 13 mm and four different thicknesses (core/veneer: 0.4/0.4 mm, 0.5/0.5 mm, 0.6/0.6 mm and 0.8/0.7 mm. Two backgrounds, C4-shade body porcelain and an opaque background from the selected IPS e.max ceramic itself were fabricated to mimic a discolored or stained natural tooth structure and to determine the masking ability. After applying the resin cement layer (Panavia F2.0 with 0.01 mm thickness on each background, all specimens were measured on both background using a spectrophotometer and values of LFNx01, aFNx01 and bFNx01 were calculated to determine the color differences (ΔEFNx01ab. One-way ANOVA and post-hoc tests of specimen average one-to-one comparison (Tukey HSD were conducted and P ≤ 0.05 was set as the level of significance. Results: ΔEFNx01ab of all groups were within the range of the clinically acceptable color difference (ΔE ≤3.3, thus all the groups could mask the C4 background even group 1 with only 0.8 mm thickness. A trend was shown in the results as by increasing the thickness, ΔEFNx01ab is was decreased. The mean ΔE FNx011FNx01aFNx01b between different thicknesses were statistically significant (P < 0.05 only between group 4 with groups 1 and 2, respectively. Conclusion: Within the limitations of this study, all studied thicknesses could mask the C4 background. However, the minimum thickness of a multilayer porcelain restoration (IPS e.max Press required for masking

  3. Main: OPAQUE2ZM22Z [PLACE

    Lifescience Database Archive (English)

    Full Text Available OPAQUE2ZM22Z S000017 17-May-2001 (last modified) uchi Opaque-2 (O2) target sequence...ene: maize 22-kD zein; transacting factor: 02; O2; opaque; 22-kD zein; seed; ACGT; opaque-2; maize (Zea mays) TCCACGTAGA ...

  4. Evidence of yttrium silicate inclusions in YSZ-porcelain veneers.

    Science.gov (United States)

    Stoner, Brian R; Griggs, Jason A; Neidigh, John; Piascik, Jeffrey R

    2014-04-01

    This report introduces the discovery of crystalline defects that can form in the porcelain veneering layer when in contact with yttria-stabilized zirconia (YSZ). The focus was on dental prostheses and understanding the defects that form in the YSZ/porcelain system; however the data reported herein may have broader implications toward the use and stability of YSZ-based ceramics in general. Specimens were cut from fully sintered YSZ plates and veneering porcelain was applied (porcelain veneer. Local EDAX (SEM) was performed in the regions of visible inclusions and showed significant increases in yttrium concentration. TEM specimens also showed apparent inclusions in the porcelain and selected area electron diffraction was performed on these regions and found the inclusions to be crystalline and identified as either yttrium-silicate (Y2 SiO5 ) or yttrium-disilicate (Y2 Si2 O7 ). Micro-CT data showed that yttrium-silicate precipitates were distributed throughout the thickness of the porcelain veneer. Future studies are needed to determine whether many of the premature failures associated with this materials system may be the result of crystalline flaws that form as a result of high temperature yttrium diffusion near the surfaces of YSZ.

  5. 21 CFR 872.3920 - Porcelain tooth.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Porcelain tooth. 872.3920 Section 872.3920 Food... DEVICES DENTAL DEVICES Prosthetic Devices § 872.3920 Porcelain tooth. (a) Identification. A porcelain tooth is a prefabricated device made of porcelain powder for clinical use (§ 872.6660) intended for...

  6. Proton induced X-ray emission (PIXE) analysis of sources of porcelain body of Ru Guan and Jun Guan porcelains

    Institute of Scientific and Technical Information of China (English)

    LI Guoxia; ZHAO Wenjun; CHENG Huansheng; ZHAO Weijuan; LI Rongwu; SUN Hongwei; GUO Min; WANG Yanfang; LIU Hui; ZHAO Qingyun; SUN Xinmin

    2006-01-01

    34 samples of Ru Guan porcelain body and 50 samples of Jun Guan porcelain body (both kinds being in different body colors) were selected with the purpose of finding out the source of raw materials and their classification relationship so as to search for ways of non-destructive discrimination. Proton induced X-ray emission (PIXE) has been applied to these samples to determine their chemical elements. The data of seven major chemical elements collected from these samples were further studied through fuzzy cluster analysis. Results indicate that the origin of raw materials of Jun Guan porcelain body samples is comparatively more concentrated in certain places, while that of Ru Guan porcelain body samples is scattered about. The places of origin of raw materials of the majority of Ru Guan and Jun Guan porcelain body samples have something in common, but some differences still exist. It might be an important way for non-destructive discrimination among Ru Guan and Jun Guan porcelains by combining PIXE with fuzzy cluster analysis.

  7. Porcelain enamel neutron absorbing material

    Science.gov (United States)

    Iverson, Daniel C.

    1990-01-01

    A porcelain enamel composition as a neutron absorbing material can be prepared of a major proportion by weight of a cadmium compound and a minor proportion of compounds of boron, lithium and silicon. These compounds in the form of a porcelain enamel coating or layer on several alloys has been found to be particularly effective in enhancing the nuclear safety of equipment for use in the processing and storage of fissile material. The composition of the porcelain enamel coating can be tailored to match the coefficient of thermal expansion of the equipment to be coated and excellent coating adhesion can be achieved.

  8. Minimum thickness anterior porcelain restorations.

    Science.gov (United States)

    Radz, Gary M

    2011-04-01

    Porcelain laminate veneers (PLVs) provide the dentist and the patient with an opportunity to enhance the patient's smile in a minimally to virtually noninvasive manner. Today's PLV demonstrates excellent clinical performance and as materials and techniques have evolved, the PLV has become one of the most predictable, most esthetic, and least invasive modalities of treatment. This article explores the latest porcelain materials and their use in minimum thickness restoration.

  9. Main: OPAQUE2ZMB32 [PLACE

    Lifescience Database Archive (English)

    Full Text Available OPAQUE2ZMB32 S000077 17-May-1998 (last modified) kehi opaque-2 binding site of maiz...complex (GARC)(Rogers and Rogers, 1992); opaque-2; o2; b-32; O2; O2S; coupling element; GARC; GARE; seed; maize (Zea mays) GATGAYRTGG ...

  10. [Mass Spectrometric Methods for Colorative Mechanism Analysis of Yaozhou Porcelain Glaze].

    Science.gov (United States)

    Xiao, Yuan-fang; He, Miao-hong; Zhang, Shu-di; Hang, Wei

    2015-09-01

    An in-house-built femtosecond laser ionization time-of-flight mass spectrometry (fs-LI-TOFMS) has been applied to the multi-elemental analysis of porcelain glaze from Yaozhou kiln. The samples are selected representing products of different dynasties, including Tang, Five, Song, Jin, and Ming Dynasty. For exploring the colorative mechanism of Yaozhou porcelain through the elemental analysis of the glaze, the effects of all potential coloring elements, especially transition elements, were considered. There was a speculation that the typical Co-Cr-Fe-Mn recipe was used in the fabrication of Yaozhou black glaze; the low content of Fe and high content of Ni resulted in the porcelain of white glaze; an increase content of P could lead the porcelain to be yellow-glazed. Undoubtedly, this research is an important supplement to the study of the colorative mechanism of the Yaozhou porcelain system.

  11. Woman Issues Green Card for Porcelain

    Institute of Scientific and Technical Information of China (English)

    1995-01-01

    "GREAT, great," praised a Canadian businessman when he saw the set porcelain samples for microwave ovens in July this year, which were recently produced by the Huamei Porcelain Ltd,. Company in Tangshan, Hebei Province. "This is another marvel that Huamei

  12. Porcelain enamel passive thermal control coatings

    Science.gov (United States)

    Leggett, H.; King, H. M.

    1978-01-01

    This paper discusses the development and evaluation of a highly adherent, low solar absorptance, porcelain enamel thermal control coating applied to 6061 and 1100 aluminum for space vehicle use. The coating consists of a low index of refraction, transparent host frit and a high volume fraction of titania as rutile, crystallized in-situ, as the scattering medium. Solar absorptance is 0.21 at a coating thickness of 0.013 cm. Hemispherical emittance is 0.88. The change in solar absorptance is 0.03, as measured in-situ, after an exposure of 1000 equivalent sun hours in vacuum.

  13. Cholecystoduodenal fistula in a porcelain gallbladder

    Energy Technology Data Exchange (ETDEWEB)

    Delpierre, I.; Tack, D.; Delcour, C. [Department of Radiology, CHU-Hopital Civil de Charleroi, 92 Boulevard Janson, 6000 Charleroi (Belgium); Moisse, R. [Department of Gastroenterology, CHU-Hopital Civil de Charleroi, 92 Boulevard Janson, 6000 Charleroi (Belgium); Boudaka, W. [Department of Surgery, CHU-Hopital Civil de Charleroi, 92 Boulevard Janson, 6000 Charleroi (Belgium)

    2002-09-01

    Calcification of the gallbladder wall (porcelain gallbladder) is rare. Its appearance is quite characteristic on plain films, ultrasonography and computed tomography. Sporadic cases of cholecystitis have been described in porcelain gallbladders. Enterobiliary fistula may complicate acute or chronic cholecystitis in non-calcified gallbladder. We report a unusual case of acute cholecystitis with cholecystoduodenal fistula in a porcelain gallbladder. (orig.)

  14. Paleodose evaluation of porcelain: a practical regression method of saturation exponential in pre-dose technique

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A practical regression method of saturation exponential in pre-dose technique is proposed. The method is mainly applied for porcelain dating. To test, the method, some simulated paleodoses of the imitations of ancient porcelain were used. The measured results are in good agreement with the simulated values of the paleodoses, and the average ratios of the two values by using the two ways are 1.05 and 0.99 with standard deviations (±lσ) of 19% and 15% respectively. Such errors can be accepted in porcelain dating.

  15. Shear bond strength of a hot pressed Au-Pd-Pt alloy-porcelain dental composite.

    Science.gov (United States)

    Henriques, B; Soares, D; Silva, F S

    2011-11-01

    The purpose of this study was to evaluate the effect of hot pressing on the shear bond strength of a Au-Pt-Pd alloy-porcelain composite. Several metal-porcelain composites specimens were produced by two different routes: conventional porcelain fused to metal (PFM) and hot pressing. In the latter case, porcelain was hot pressed onto a polished surface (PPPS) as well as a roughened one (PPRS). Bond strength of all metal-porcelain composites were assessed by the means of a shear test performed in a universal test machine (crosshead speed: 0.5 mm/min) until fracture. Interfaces of fractured specimens as well as undestroyed interface specimens were examined with optical microscope, stereomicroscope, Scanning Electron Microscope (SEM) and Energy Dispersive X-Ray Spectroscopy (EDS). The data were analyzed using one-way ANOVA followed by Tuckey's test (p0.05). This study shows that it is possible to significantly improve metal-porcelain bond strength by applying an overpressure during porcelain firing. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. "Lan Ji" Gree-White Porcelain Case

    Institute of Scientific and Technical Information of China (English)

    1994-01-01

    The invention of porcelain is one of China’s greatest contributions to world civilization. Many people have gotten to know China through its porcelain. As we all know, zhongguo and ciqi have the same spelling in English. Green-white porcelain represents a typical style that was fired in the Jingdezhen china kiln which represented the features of the Song Dynasty china kilns. The glaze is a mixture of white and green. The white can be

  17. The Discovery of European Porcelain Technology

    CERN Document Server

    Queiroz, C M

    2005-01-01

    The European quest for the hard paste porcelain lasted until about 1710, when the first production unit was built at Meissen in Saxony. Although, it is generally believed that Bottger discovered the European porcelain technology, this work shows that the German porcelain quest was a State affair; a collective project directed by Tschirnhaus and supported by August the Strong. It also aims to shed light to the reasons that led to Tschirnhaus's relative oblivion. Considering three distinct temporal stages, we re-examine the roles of the main contributors to the porcelain project, referring to the role of the Mercantilism system and to the philosophical roots of Tschirnhaus's method.

  18. A Family in the Porcelain City

    Institute of Scientific and Technical Information of China (English)

    1996-01-01

    IN Jingdezhen, the Porcelain City of China, people began to make porcelain during the Han dynasties (206 B.C.-220 A.D.). Jingdezhen is world renowned for its innumerable superb porcelain products. One type is blue and white porcelain with a red underglaze. Legend has it that the humorous King of Fire liked to play jokes with the red underglaze. When the temperature of the kiln is slightly different, the red underglaze will become brown, yellow, grey or black; sometimes it will even vanish. In other

  19. A passion for Qing Hua porcelain

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Ovet the past two thousand years of China's porcelain production. different kinds of product -celadon, white potct:lain, blue and white porcelain and eoloured porcelain - were dominant in different periods. However, in the 15th century (the early Mingdynasty), Qing Hua porcelain replaced celadon and became the dominant variety both in terms of production and export. Originated in China, Qing Hua porelain is primarily while, with a superimposed blue design - delicate and light irt eolour. Its patterns never fade, and the designs of flora, fauna and other characters in the Chinese ink and washed painting style are pteasing to the eye.

  20. CO2 laser conditioning of porcelain surfaces for bonding metal orthodontic brackets.

    Science.gov (United States)

    Ahrari, Farzaneh; Heravi, Farzin; Hosseini, Mohsen

    2013-07-01

    Bonding to porcelain remains to be a challenge in orthodontic treatments. The objective of this study was to evaluate the effect of CO2 laser conditioning of porcelain surfaces on shear bond strength (SBS) of orthodontic brackets. Eighty feldspathic porcelain specimens were divided into four groups of 20. In each group, half of the porcelain surfaces were deglazed, while the others remained glazed. The specimens in groups 1 to 3 were treated with a fractional CO2 laser for 10 s using 10 mJ of energy, frequency of 200 Hz and powers of 10 W (group 1), 15 W (group 2) and 20 W (group 3). In group 4, a 9.6 % hydrofluoric (HF) acid gel was used for 2 min. A silane coupling agent was applied before bracket bonding, and the SBS was measured with a universal testing machine after 24 h. Deglazing caused significant increase in SBS of laser treated porcelain surfaces (p porcelain.

  1. Porcelain veneers - preparation design: A retrospective review

    Directory of Open Access Journals (Sweden)

    Obradović-Đuričić Kosovka B.

    2014-01-01

    Full Text Available This paper discusses the preparation of tooth design for porcelain veneers. It follows the literature more than three decades back in the past. From the very beginning, porcelain veneers were placed to no/minimally prepared tooth substance, showing different problems in clinical use. Later, the technique of etching the porcelain and controlling the reduction of tooth structure, presented the great steps forward in porcelain veneers accepting. A special accent concerning the preparative design was placed on variations of incisal edge preparation - the problem, which is still present in current practice. Additionally, the paper emphasizes the extremely demanding protocols in making the porcelain veneers as well as their expanded clinical indications.

  2. 46 CFR 111.01-13 - Limitations on porcelain use.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Limitations on porcelain use. 111.01-13 Section 111.01... SYSTEMS-GENERAL REQUIREMENTS General § 111.01-13 Limitations on porcelain use. Porcelain must not be used... solidly mounted by machine screws or their equivalent, unless the porcelain piece is resiliently mounted....

  3. Comparison of Shear Bond Strength between Composite Resin and Porcelain Using Different Bonding Systems

    Directory of Open Access Journals (Sweden)

    E.Yassini

    2005-03-01

    Full Text Available Statement of Problem: Ceramics as in ceramo-metallic and all ceramic tooth restorations have grown popular owing to their high tissue compatibility and esthetic advantages. Such restorations have the capability to deliver valuable services over a long period of time; however, failures under intraoral conditions are not unanticipated.Purpose: The purpose of this in-vitro study was to investigate the shear bond strength of composite resin to porcelain using different bonding system materials.Materials and Methods: In this experimental study forty porcelain blocks were prepared and randomly divided into four equal groups. The porcelain surfaces were then etched with HF for 2 minutes, washed with water for 2 minutes and treated with a silane layer. The silane treated porcelain surfaces were left for one minute and then the specimens were bonded to composite resin as follow:Group 1 (control group, hybrid composite Z100 was applied and light cured from four directions for 20 seconds. Group 2, flowable composite was applied and light cured for 20 seconds. Group 3, unfilled resin was used and photo cured for 20 seconds. Group 4,(Dentin bonding agent adhesive resin was used followed by 20 seconds photo curing.Hybrid composite resin Z100 was subsequently applied on all porcelain surfaces of groups 2, 3 and 4, and light cured for 20 seconds from four directions. Specimens were then subjected to thermocycling 1000 times. Shear bond strength was determined by a Universal testing machine. The data obtained was subjected to a one-way ANOVA test.Results: The results indicate that there is a statistically significant difference between adhesive group and the other three groups of hybrid, flowable and unfilled resin (P<0.05.Conclusion: The results from this study showed that the shear bond strength of composite resin to porcelain was significantly higher for porcelain bonded surfaces using a dentin bonding agent than that of other materials tested.

  4. Evaluation of five primers and two opaque resins for bonding ceria-stabilized zirconia/alumina nanocomposite

    Directory of Open Access Journals (Sweden)

    Kohji Kamada

    2017-03-01

    Full Text Available The purpose of this study was to evaluate the effect of five primers [Super-Bond C&B Monomer (SB, Clearfil Ceramic Primer, Alloy Primer, M.L. Primer, and AZ Primer] and two undercoating opaque resins [Super-Bond C&B (S-opaque and Ceramage Pre-opaque (C-opaque] on the bonding of a resin composite veneering material to a ceria-stabilized tetragonal zirconia polycrystals/alumina nanocomposite (Ce-TZP/Al2O3. Disk-shaped specimens of Ce-TZP/Al2O3 were sandblasted with alumina and primed. The undercoating opaque resins and resin composites were subsequently applied to the specimen, and then light cured. After 5000 thermocycles at 4°C and 60°C, shear bond strengths were determined. Data were analyzed using analysis of variance, Tukey–Kramer honest significant difference test, and Student t test (n = 10, α = 0.05. With the exception of SB/S-opaque, all S-opaque groups exhibited significantly higher bond strengths than C-opaque groups. The use of S-opaque resin is recommended when veneering frameworks made of Ce-TZP/Al2O3.

  5. Cross-contamination in Porcelain Mortars.

    Science.gov (United States)

    Bauer-Brandl, A; Falck, A; Ingebrigtsen, L; Nilson, C

    2001-01-01

    Porcelain mortars and pestles are frequently used to comminute drug substances on a small scale and (in some cases) in the production of liquid and semisolid suspensions. Although it is generally accepted that removal of a drug substance from a rough surface by rinsing may be difficult and may lead to cross-contamination, no hard data support that theory. In this study, the amount of salicylic acid remaining on a porcelain mortar after different washing procedures was quantified and compared with the amount remaining on a plastic mortar. Drug residues in the "mg" range on the porcelain mortars made common rinsing procedures appear inappropriate, but no traces of drug were detected on plastic mortars. In addition, the quality of suspension ointments with respect to particle size and homogeneity produced by the two types of mortars was compared. Porcelain and plastic mortars appeared equally suitable for use in the production of semisolid suspensions.

  6. Porcelain Gallbladder; Decoding the malignant truth

    Directory of Open Access Journals (Sweden)

    Norman O. Machado

    2016-11-01

    Full Text Available Gallbladder calcification, also referred to as porcelain gallbladder, has received significant attention in the medical literature due to its perceived role in increasing the risk of developing a gallbladder carcinoma. However, recent reports raise questions challenging this purported high risk. While previous studies reported a concomitant incidence of gallbladder cancer in porcelain gallbladder ranging from 7–60%, more recent analyses indicate the incidence to be much lower (6%. Based on evidence in the current literature, a prophylactic cholecystectomy is not routinely recommended for all patients with porcelain gallbladder and should be restricted to those with conventional indications, such as young patients. However, it is important to note that a nonoperative approach may require prolonged follow-up. A laparoscopic cholecystectomy is a feasible therapeutic option for patients with porcelain gallbladder, although some researchers have indicated a higher incidence of complications and conversion due to technical difficulties.

  7. Effects of airborne-particle abrasion, sodium hydroxide anodization, and electrical discharge machining on porcelain adherence to cast commercially pure titanium.

    Science.gov (United States)

    Acar, Asli; Inan, Ozgür; Halkaci, Selçuk

    2007-07-01

    The aim of this study was to determine the effect of airborne-particle abrasion (APA), sodium hydroxide anodization (SHA), and electrical discharge machining (EDM) on cast titanium surfaces and titanium-porcelain adhesion. Ninety titanium specimens were cast with pure titanium and the alpha-case layer was removed. Specimens were randomly divided into three groups. Ten specimens from each group were subjected to APA. SHA was applied to the second subgroups, and the remaining specimens were subjected to the EDM. For the control group, 10 specimens were cast using NiCr alloy and subjected to only APA. Surfaces were examined by using scanning electron microscope and a surface profilometer. Three titanium porcelains were fused on the titanium surfaces, whereas NiCr specimens were covered with conventional porcelain. Titanium-porcelain adhesion was characterized by a 3-point bending test. Statistical analysis showed that the porcelain-metal bond strength of the control group was higher than that of the titanium-porcelain system (p < 0.05). There were no significant differences between the bond strengths of titanium groups (p 0.05), except the bond strengths of Noritake Super Porcelain TI-22 groups on which APA and SHA were applied (p < 0.05). SHA and EDM as surface treatment did not improve titanium-porcelain adhesion when compared to APA.

  8. Influence of bone porcelain scraps on the physical characteristics and phase composition of a hard porcelain body

    Energy Technology Data Exchange (ETDEWEB)

    Nodeh, A.A.

    2017-07-01

    Hard porcelain is constituted in the alkali oxides-alumina-silica ternary system, and produced by a mixture of clay-feldspar and silica. The most important properties of this porcelain are high mechanical strength, translucency and whiteness. These properties depend on quality of raw material, firing temperature and soaking time. In bone porcelain bone ash was added to body composition up to 50wt.%. Generally hard porcelain and bone porcelain scrap cannot be reused in body composition. Whereas using these scrap could help natural resources. In this research using bon porcelain scraps in hard porcelain body have been investigated. Results show, this substitution decrease firing temperature, linear expansion and increase glass, probability of deformation and total shrinkage. Using 6wt.% bone porcelain scraps to hard porcelain body composition besides improving some properties, increases 1340°C firing mechanical strength two times and helps natural resources. (Author)

  9. Bonding brackets to porcelain: in vitro study

    Directory of Open Access Journals (Sweden)

    Sant'Anna Eduardo Franzotti

    2002-01-01

    Full Text Available The aim of this research was to verify, in vitro, the effect of various porcelain surface treatments on the shear strength of orthodontic brackets bonded to porcelain and the mode of fracture after debonding. Eighty-eight samples of metallic supported feldspathic porcelain were randomly divided into four groups according to their surface preparation as follows: the porcelain was maintained intact (GI, roughened with a diamond bur (GII, etched with 10% hydrofluoric acid (GIII, or sandblasted with aluminum oxide (GIV. The specimens were treated with silane (Scothprime and brackets were bonded with Concise. Each sample was subjected to a shear load at a crosshead speed of 1 mm/min and a recording was made at the point of failure. Bond strengths, adequate to withstand the application of orthodontic forces, were achieved in all groups. The Kruskal-Wallis statistical test showed no significant differences in bond strength between the groups (p>0.05. However, many more porcelain fractures occurred on deglazed porcelain. This study indicates that with the appropriate material selection, the silane/composite procedure alone may be adequate for bonding.

  10. Making Usable, Quality Opaque or Transparent Soap

    Science.gov (United States)

    Mabrouk, Suzanne T.

    2005-01-01

    The experiment to make opaque and transparent soap, using cold and semi boiled processes respectively, and surfactant tests that measure the pH of the prepared soap, is introduced. The experiment shows an easy method to make soap by giving a choice to select oils and scents for the soap, which can be used at home.

  11. Gender activation in transparent and opaque words.

    Science.gov (United States)

    Urrutia, Mabel; Domínguez, Alberto; Alvarez, Carlos J

    2009-02-01

    Two reaction time experiments were carried out to examine the morphological gender processing of Spanish words that were either transparent -that is, ending in o/a (e.g., banco - bank)-or opaque-that is, without superficial gender marking (e.g., virtud - virtue). In Experiment 1, participants categorized the gender of a transparent gender target preceded by a derived word of the same gender (e.g., banquillo-dock, masculine) or of different gender (e.g., banqueta-stool, feminine). A negative priming gender effect indicates the use of strategic-attentional mechanisms to decide the gender of the target, but also automatic computation of the prime gender. Experiment 2 used a lexical decision task with the stimuli of Experiment 1 in addition to opaque gender words. The results show longer reaction times for transparent gender words with regard to opaque items. This effect was possibly due to the lexical requirements of the task: lexical decision, and also because transparent words are morphologically more complex than opaque words. Finally, in both experiments, there was negative priming: when prime and target were of the same gender, reaction times were longer. This effect indicates that participants cannot ignore the gender of the prime when they respond to the target.

  12. Effect of Porcelain Surface Pretreatments on Composite Resin-Porcelain Shear Bond Strength

    Science.gov (United States)

    1991-05-01

    Release lAW 190-1 Distributed Unlimited ERNEST A. HAYGOOD, ist Lt, USAF Executive Officer 13. ABSTRACT (Maximum 200 words ) 14. SUBJECT TERMS 15. NUMBER OF...Bonding Orthodontic Attachments to Porcelain Teeth Using a Silane Coupling Agent, Am J Orthod 77: 233. Jones, D. W. (1985): Low Fusing Porcelains. In

  13. Fracture resistance of zirconia-composite veneered crowns in comparison with zirconia-porcelain crowns.

    Science.gov (United States)

    Alsadon, Omar; Patrick, David; Johnson, Anthony; Pollington, Sarah; Wood, Duncan

    2017-02-11

    The objectives were to evaluate the fracture resistance and stress concentration in zirconia/composite veneered crowns in comparison to zirconia/porcelain crowns using occlusal fracture resistance and by stress analysis using finite element analysis method. Zirconia substructures were divided into two groups based on the veneering material. A static load was applied occlusally using a ball indenter and the load to fracture was recorded in Newtons (N). The same crown design was used to create 3D crown models and evaluated using FEA. The zirconia/composite crowns subjected to static occlusal load showed comparable results to the zirconia/porcelain crowns. Zirconia/composite crowns showed higher stress on the zirconia substructure at 63.6 and 50.9 MPa on the zirconia substructure veneered with porcelain. In conclusion, zirconia/composite crowns withstood high occlusal loads similar to zirconia/porcelain crowns with no significant difference. However, the zirconia/composite crowns showed higher stress values than the zirconia/porcelain crowns at the zirconia substructure.

  14. Shear Bond Strength of Composite-Resin to Porcelain: Effect of Thermocycling

    Directory of Open Access Journals (Sweden)

    M. Khoroushi

    2007-03-01

    Full Text Available Objective: Different ceramic repair systems have been reported for fractured ceramics.However, limited information is available concerning the bond strength of these systems especially after thermocycling. The aim of this in-vitro study was to determinethe effect of thermocycling on the shear bond strength of composite-resin to feldspathic porcelain with and without silane pretreatment.Materials and Methods: In this experimental study, forty porcelain blocks were prepared and randomly divided into four groups (n=10. All porcelain surfaces were etched with 9.6% hydrofluoric acid, rinsed and air dried. In groups 1 and 3, silane pretreatment was applied using Adper Scotchbond Multipurpose Plus (ASMP.Smallparticlecomposite-resin was subsequently added on the ceramic surfaces, and lightcured.Specimens of groups 3 and 4 then subjected to 1000 thermal cycles. Shear bond strength was determined on a universal testing machine at a crosshead speed of 1mm/min. Two-way ANOVA test (α=0.05 was used to analyze the bond strength.Results: There were statistically significant differences between study groups (P<0.05.Thermocycling caused a decrease in the shear bond strength for both silanized and nonsilanized groups.Conclusion: According to the results of this study, shear bond strength after thermocycling reduced considerably in ASMP system. In addition, silane treatment of porcelain was critical for achieving durable bond strength between composite-resin and porcelain.

  15. A comparison on the flexural strength of a new dental porcelain (D.} Dentin with Vita company Dentin porcelain (VMK 68N

    Directory of Open Access Journals (Sweden)

    Ghahramanloo A.

    2004-06-01

    Full Text Available Statement of Problem: Dental porcelain is one of the best materials ever used in dentistry. Excellent tissue"ncompatibility, esthetics, very low solubility in oral fluids, high compressive strength, and the lowest bacterial"nplaque accumulation on the glazed porcelain are some of its advantages. Porcelain brittleness due to its low"ntensile strength, impact strength and the occlusal attrition of opposing teeth enamel are some of its"ndisadvantages. The most important mechanical properties of dental porcelains are their flexural strength that is"nthe ability of a porcelain to resist fracture when loaded from above. Different ways have been proposed to"neliminate porcelain brittleness and develop its flexural strength, among which baking porcelain on a metal"nframework is more commonly used."nPurpose: Considering that restoration and replacement of teeth by porcelain fused to metal restorations is still"nthe most commonly used technique, the aim of the present study was to measure the flexural strength of a"nporcelain bonded to metal powder, D4 Dentin, and to compare it with Vita Dentin powder."nMaterials and Methods: In this experimental study, a stainless steel box, 25x5x2mm was made according to"nISO 6872: 1995 (E Standard and filled with D4 Dentin powder and Vita Dentin (VMK 68N and baked in"nVita furnace. Then 10 blocks of D^ Dentin and 10 of Vita Dentin were made. Samples were placed on the"nthree point bending test machine and force was applied the middle of each block. To analyze the data, t-"nstudent test and co-variance analysis were used."nResults: Mean flexural strength of D4 Dentin was 53.40±1.35 MPa and that of Vita Dentin was 53.86+7.38"nMPa. The difference was not statistically significant."nConclusion: According to ISO 6872: 1995 (E standard, the flexural strength of all D4 Dentin samples were"ngreater than 50 Mpa.

  16. 21 CFR 872.6660 - Porcelain powder for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Porcelain powder for clinical use. 872.6660... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6660 Porcelain powder for clinical use. (a) Identification. Porcelain powder for clinical use is a device consisting of a mixture of...

  17. Chinese Jingdezhen blue and white imperial porcelain

    Institute of Scientific and Technical Information of China (English)

    WU; Juan; LI; Jiazhi; DENG; Zequn; WANG; Changsui

    2004-01-01

    Jingdezhen blue and white imperial porcelain specimens from the Yuan, Ming and Qing dynasties have been systematically analyzed using a nondestructive test method--?energy dispersive X-ray fluorescence analysis (EDXRF). The derived data of major and trace element compositions have been treated by correspondence analysis. The variation laws of the composition patterns for Jingdezhen blue and white imperial porcelain in different historical periods owing to the change in raw materials, recipe and technology have been discussed, and a time model related to variation of element composition has been preliminarily established, It would be helpful for scientific dating of Jingdezhen blue and white imperial porcelain, and even for the studies on the whole field of identification of ancient ceramics.

  18. A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy.

    Science.gov (United States)

    Hong, Jun-Tae; Shin, Soo-Yeon

    2014-10-01

    The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (α=.05). The 3-point bending test showed the strongest (40.42 ± 5.72 MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy (37.71 ± 2.46 MPa), precious metal alloy containing 83% of gold (35.89 ± 1.93 MPa), and precious metal alloy containing 32% of gold (34.59 ± 2.63 MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

  19. Addition of platinum and silver nanoparticles to toughen dental porcelain.

    Science.gov (United States)

    Fujieda, Tokushi; Uno, Mitsunori; Ishigami, Hajime; Kurachi, Masakazu; Wakamatsu, Nobukazu; Doi, Yutaka

    2012-01-01

    Several studies have investigated toughening porcelain that is layered over a frame or a core. The introduction of residual compressive stress to the surface of porcelain has been shown to be effective to strengthen it. In the present study, nanoparticles of precious metals of silver and platinum (rather than non-precious metals) were used to evaluate if they could increase the fracture resistance of porcelain. The addition of silver and platinum nanoparticles was found to improve the mechanical properties of porcelain since it increased both the Young's modulus and the fracture toughness of commercial porcelain.

  20. Effect of porcelain shape for strain behavior of strengthened porcelain in impact test

    Science.gov (United States)

    Hayashi, Akemi; Kurachi, Kazumasa; Mizuno, Masatoshi; Ota, Toshitaka

    2011-10-01

    Four types of strengthened porcelains were evaluated by an impact examination machine based on ASTM C368-88. The waveform of strain developed on impact was measured by a strain gauge pasted on the inside surface and the outside surface, vertical and horizontal direction of porcelain. In minute scales, procelain deformed into an oval shape as a whole by an impact onto the rim, where the higher tensile strain occurred in the horizontal direction on the inside surface of porcelain. The maximum tensile strain occurred at the impact point. The waveform of strain, that showed two remarkable peaks, was greatly affected by porcelain shape. In addition it was more or less affected by measurement conditions such as impact energy, weight or speed of hammer, weight for holding, and position of backstops.

  1. Using Opaque Image Blur for Real-Time Depth-of-Field Rendering

    DEFF Research Database (Denmark)

    Kraus, Martin

    2011-01-01

    the opacity of all pixels to avoid artifacts at the cost of physically less accurate but still plausible rendering results. The proposed filter is named “opaque image blur” and is based on a glow filter that is applied to the alpha channel. We present a highly efficient GPU-based pyramid algorithm...

  2. The Artistry of Modern Chinese Porcelain

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    ■Since its invention in the T'ang Dynasty(ninth century),porcelain has beenexported all over the world.As nothing ofthe kind existed outside of China,thedelicacy and pure whiteness of Chineseporcelain was highly acclaimed and muchsought after.

  3. Polishing of dental porcelain by polycrystalline diamond.

    Science.gov (United States)

    Nakamura, Yoshiharu; Sato, Hideaki; Ohtsuka, Masaki; Hojo, Satoru

    2010-01-01

    Polycrystalline diamond (PCD) exhibits excellent abrasive characteristics and is commonly used as loose grains for precision machining of hard ceramics and other materials that are difficult to grind and polish. In the present study, we investigated using bonded PCD for polishing dental porcelain, for which a lustrous surface is difficult to obtain by polishing. We compared the surface texture and characteristics of dental porcelain after polishing with bonded PCD with that obtained using bonded monocrystalline diamond (MCD), which is commonly used for this purpose. Polishing was performed at various pressures and rotational speeds on a custom-built polishing apparatus using bonded PCD or MCD with grain sizes of 3.92 μm on specimens consisting of VITA Omega 900 dentin porcelain after firing and then glazing to a specified surface roughness. The surface roughness of the polished porcelain and the abrasion quantity in terms of its polishing depth were measured, and its surface texture and characteristics were investigated. At low polishing pressures, PCD yielded a finer polished surface than MCD. The polishing depth after polishing for 20-30 min was approximately 2-3 μm with PCD and 1-2 μm with MCD. The polished surface was more uniform and smooth with PCD than with MCD.

  4. Bond strength of binary titanium alloys to porcelain.

    Science.gov (United States)

    Yoda, M; Konno, T; Takada, Y; Iijima, K; Griggs, J; Okuno, O; Kimura, K; Okabe, T

    2001-06-01

    The purpose of this study was to investigate the bond strength between porcelain and experimental cast titanium alloys. Eleven binary titanium alloys were examined: Ti-Cr (15, 20, 25 wt%), Ti-Pd (15, 20, 25 wt%), Ti-Ag (10, 15, 20 wt%), and Ti-Cu (5, 10 wt%). As controls, the bond strengths for commercially pure titanium (KS-50, Kobelco, Japan) and a high noble gold alloy (KIK, Ishifuku, Japan) were also examined. Castings were made using a centrifugal casting unit (Ticast Super R, Selec Co., Japan). Commercial porcelain for titanium (TITAN, Noritake, Japan) was applied to cast specimens. The bond strengths were evaluated using a three-point bend test according to ISO 9693. Since the elastic modulus value is needed to evaluate the bond strength, the modulus was measured for each alloy using a three-point bend test. Results were analyzed using one-way ANOVA/S-N-K test (alpha = 0.05). Although the elastic moduli of the Ti-Pd alloys were significantly lower than those of other alloys (p = 0.0001), there was a significant difference in bond strength only between the Ti-25Pd and Ti-15Ag alloys (p = 0.009). The strengths determined for all the experimental alloys ranged from 29.4 to 37.2MPa, which are above the minimum value required by the ISO specification (25 MPa).

  5. Difference in color and color parameters between dental porcelain and porcelain-repairing resin composite.

    Science.gov (United States)

    Kim, Sung-Hee; Lee, Yong-Keun; Lim, Bum-Soon; Rhee, Sang-Hoon; Yang, Hyeong-Cheol

    2006-01-01

    The objective of this study was to measure the differences in color and color parameters between dental porcelain and porcelain-repairing resin composites. The colors of three shades (A2, A3, A3.5) of one brand of dental porcelain, three original shades (A2, A3, A3.5), and three combinations (A2/A3, A3/3.5, A2/A3.5) of three brands of porcelain-repairing resin composites (ABT, FSP, TCR) were measured. The specimens were 2 mm thick, and 1 mm of each shade was layered to make combined shades. Differences in color (DeltaE(ab) (*)), lightness (DeltaL*), chroma (DeltaC(ab) (*)), and hue (DeltaH(*)) between porcelain and resin composite were calculated. Color difference was calculated as DeltaE(ab) (*) = (DeltaL*(2) + Deltaa*(2) + Deltab*(2))(1/2), chroma difference was calculated as DeltaC(ab) (*) = (Deltaa*(2) + Deltab*(2))(1/2), and hue difference was calculated as DeltaH(ab) (*) = (DeltaE(ab) (*2) - DeltaL*(2) - DeltaC(ab) (*2))(1/2). The influence of porcelain shade, brand of resin composites, and shade of resin composites were analyzed by three-way analyses of variance, and the differential influence of color parameters on color difference was analyzed with multiple regression analysis (alpha = 0.05). Differences in color and color parameters were influenced by the porcelain shade, brand and shade of resin composites. The DeltaE(ab) (*) value was in the range of 2.2-16.9. The DeltaE(ab) (*) value was correlated with DeltaC(ab) (*) (standardized correlation coefficient, beta = - 0.85), DeltaL* (beta = - 0.52), and DeltaH(ab) (*) (beta = 0.08). Between the same shade designated pairs of porcelain and repairing composite, color difference was perceptible. Therefore, studies to improve the color matching between porcelain and repairing resin are recommended.

  6. Wavefront shaping for opaque cylindrical lenses

    CERN Document Server

    Di Battista, Diego; Ancora, Daniele; Lemonaki, Krystalia; Liapis, Evangelos; Tzortzakis, Stelios; Zacharakis, Giannis

    2016-01-01

    Wavefront shaping has revolutionized the concepts of optical imaging and focusing. Contrary to what was believed, strong scattering in the optical paths can be exploited in favor of light focusing through turbid media and ultimately improve optical imaging and light manipulation capabilities. The use of light shapers and appropriately engineered scattering structures, i.e. opaque lenses enables the production of nano-scale confined foci and of extended fields of view. Exploiting this concept we fabricate configurable scattering structures by direct femtosecond laser writing. The properly shaped light trespassing the customized structure, a photonic lattice of parallel rods, forms a light-sheet at user defined positions. We demonstrate that our technique enables light-sheets with sub-micron resolution and extended depth of focus, a significant advantage when compared to the existing free space systems. Moreover, our approach permits to focus light of different wavelengths onto the same defined position without...

  7. Surface treatment of dental porcelain: CO2 laser as an alternative to oven glaze.

    Science.gov (United States)

    Sgura, Ricardo; Reis, Mariana Cavalcante; Hernandes, Antonio Carlos; de Abreu Fantini, Márcia Carvalho; Andreeta, Marcello Rubens Barsi; Medeiros, Igor Studart

    2015-02-01

    This work tested continuous CO2 laser as a surface treatment to dental porcelain and compared it to oven glaze (auto-glaze) by means of roughness and color parameters. Three commercial veneering porcelains with different crystalline content were tested: VM7, VM9, and VM13. Porcelain discs (3.5 × 2.0 mm, diameter × height) were sintered and had one side ground by a diamond bur (45 μm) simulating a chairside adjustment in a clinical office. Specimens (n = 7) were divided into the following groups: C--control (no treatment), G--auto-glaze (oven), and L--surface continuous irradiation with CO2 laser (Gem Laser, Coherent; λ = 10.6 μm). Laser was tested in three exposure times (3, 4, or 5 min) and two irradiances (45 and 50 W/cm(2)). Roughness parameters (Ra, Rz, and Rpm/Rz) were measured using a rugosimeter (Surftest 301, Mitutoyo). Color differences (ΔE) between the G and L groups were calculated (VITA Easyshade); ΔE values up to 3.3 were considered as not perceivable. A surface analysis was conducted by stereomicroscopy (Olympus SZ61) and SEM (Stereoscan 440, LEO). Crystalline content of specimens from groups C and L (50 W/cm(2), 5 min) was assessed by X-ray diffraction and then compared. Surface roughness (Ra and Rz) observed for laser-irradiated groups was similar to G for all studied porcelains. Rpm/Rz ratios were near 1.0 for all groups that indicated a sharp ridge profile for all specimens. Only one laser condition studied (50 W/cm(2), 3 min) from VM7 porcelain resulted in color difference (ΔE = 3.5) to G. Specimens irradiated with 50 W/cm(2) for 5 min presented the smoother surface observed by SEM, comparable to G. X-ray diffraction data revealed an increase in leucite crystallite size for VM9 and VM13 porcelains after laser treatment. Regarding roughness, continuous CO2 laser applied on porcelain surface was as effective as conventional oven auto-glaze.

  8. Fracture of porcelain-veneered structures in fatigue.

    Science.gov (United States)

    Kim, B; Zhang, Y; Pines, M; Thompson, V P

    2007-02-01

    Porcelain-veneered crowns are widely used in modern dentistry, and their fracture remains problematic, especially in all-ceramic systems. We hypothesized that substructure properties have a significant effect on the longevity of porcelain-veneered crowns. Flat porcelain/metal or porcelain/ceramic structures were cemented to dentin-like composite, and a mouth-motion cyclic load of 200 N was delivered by means of a tungsten carbide spherical indenter (r = 3.18 mm), emulating occlusal loading on crowns supported by dentin. Findings indicated that porcelain on a low-hardness gold-infiltrated alloy was vulnerable to both occlusal surface contact damage and porcelain lower surface radial fracture, while porcelain on a higher-hardness palladium-silver alloy fractured chiefly from occlusal surface damage. The advantage of a high-modulus metal substructure was less pronounced. Fracture in the porcelain/zirconia system was limited to surface damage in the veneer layer, similar to that in the porcelain/palladium-silver system. Bulk fracture, observed in veneered alumina layers, was not found for zirconia.

  9. Photocatalytic, highly hydrophilic porcelain stoneware slabs

    Science.gov (United States)

    Raimondo, M.; Guarini, G.; Zanelli, C.; Marani, F.; Fossa, L.; Dondi, M.

    2011-10-01

    Photocatalytic, highly hydrophilic industrial porcelain stoneware large slabs were realized by deposition of nanostructured TiO2 coatings. Different surface finishing and experimental conditions were considered in order to assess the industrial feasibility. Photocatalytic and wetting behaviour of functionalized slabs mainly depends on surface phase composition in terms of anatase/rutile ratio, this involving - as a key issue - the deposition of TiO2 on industrially sintered products with an additional annealing step to strengthen coatings' performances and durability.

  10. [Study on porcelain veneer restorations. 2. Influence of hydrofluoric acid on bonding strength at the porcelain-resin interface].

    Science.gov (United States)

    Gomi, A; Ikeda, M; Takeuchi, N; Ban, Y; Kamiya, K; Kanamori, K; Asai, T; Senda, A

    1990-06-01

    Recently, porcelain veneer restoratives have been introduced to the general practice, and their clinical performances have been confirmed through many longterm clinical investigations. It is expected that porcelain veneer restorations will perform successfully in esthetic, conservative and abhesive dentistry. It is an well known fact that the micro-mechanical bonding strength at the porcelain-resin interface which is achieved through the application of hydrofluoric acid to the porcelain surface is quite a strong bonding mechanism. However, there are very few studies reporting on the acid treatment of porcelain surfaces. The authors have been studying the influence of hydrofluoric acid on porcelain surfaces, and in our previous report we reported, the degrees of corroded porcelain treated with different concentrations of hydrofluoric acid for different durations of application. In the present study, shear bonding strength was measured between resin cements and porcelain surfaces treated with different concentrations (4, 6, 8%) of hydrofluoric acid and for different durations (1 to 24 min.), and the appropriate treatment of porcelain surfaces with regard to the bonding strength was determined. The results obtained were as follows. 1. As the treating time increased with any concentration (4, 6, 8%) of hydrofluoric acid, corrosion of the porcelain surface became more intense. Hardly any evidence of corrosion was observed on any porcelain surface treated for one minute, so it seems that the treatment of porcelain surfaces using 4 to 8% hydrofluoric acids should be continued for over three minutes. 2. Observation of the surface profile by SEM showed no significant differences between the surfaces treated for 3, 6, 12 and 24 minutes. 3. It was not clear as to how the differences of hydrofluoric acid concentrations (4, 6, 8%) plus the differences in the kinds of porcelain (Super Porcelain AAA, NORITAKE Co. Ltd., VMK 68, Vita Zahnfabrik Gmbh & Co., Cosmotech Porcelain, G

  11. Evaluating bond strength of porcelain to dental alloys and the effects of repeated porcelain sintering on it

    Directory of Open Access Journals (Sweden)

    n. Rashidan

    1998-05-01

    Full Text Available   In this study, porcelain bond strength to three different alloys of Gold-base, pd-Ag and base-Metal were compared and the effect of repeated porcelain sintering on bond strength was evaluated. The obtained results showed best bond strength of porcelain with Gold-base alloy. Pd-Ag and Base-metal alloys showed less strength respectively. During repeated sintering of porcelain, bond strength has not changed in Base-metal and Gold-base alloys while it was weakened in pd-Ag alloy.

  12. Evaluation of zirconia bonding to veneering porcelain

    Directory of Open Access Journals (Sweden)

    Aneta Mijoska

    2014-10-01

    Full Text Available Zirconium dioxide as core ceramic material for dental crowns and bridges, possess high strength, chemical stability and superior aesthetics after veneering. Veneering ceramic is considered to be the weakest part of all-ceramic restorations. The adhesion between the core and veneering porcelain is based on the manner in which the connection occurs in metal-ceramic structures. Standard procedures for connecting zirconia to hard dental tissues and veneering materials do not achieve the required strength of bonding. The aim of the paper is to investigate different surface treatments of the zirconium dioxide ceramic core and find the best, for achieving highest adhesive bonding values to veneering porcelain. The study was primarily designed to investigate the bonding strength of the veneering porcelain to zirconia with in vitro Macro shear bond strength test. The specimens with different surface treatment of the zirconia were divided in five groups of twelve according to the treatment of zirconium surface and results showed highest bonding values for specimens treated with Rocatec system.

  13. Contact fatigue response of porcelain-veneered alumina model systems.

    Science.gov (United States)

    Stappert, Christian F J; Baldassarri, Marta; Zhang, Yu; Stappert, Dina; Thompson, Van P

    2012-02-01

    Fatigue damage modes and reliability of hand-veneered (HV) and over-pressed (OP) aluminum-oxide layer structures were compared. Influence of luting cement thickness on mechanical performance was investigated. Sixty-four aluminum-oxide plates (10 × 10 × 0.5 mm) were veneered with hand built-up or pressed porcelain (0.7 mm) and adhesively luted (50- or 150-μm cement thickness) to water-aged composite resin blocks (12 × 12 × 4 mm). Single-load-to-failure and fatigue tests were performed with a spherical tungsten carbide indenter (d = 6.25 mm) applied in the center of the veneer layer. Specimens were inspected with polarized-reflected-light and scanning electron microscopy. Use-level probability Weibull curves were plotted with two-sided 90% confidence bounds, and reliability at 75,000 cycles and 250 N load was calculated. For all specimens but two OP with 50-μm cement thickness, failure was characterized by flexural radial cracks initiating at the bottom surface of the alumina core and propagating into the veneering porcelain before cone cracks could extend to the porcelain/alumina interface. HV specimens showed higher reliability compared to OP. Those with 50-μm cement thickness were more reliable relative to their 150-μm counterparts (HV_50 μm: 95% (0.99/0.67); HV_150 μm: 55% (0.92/0.01); OP_50 μm: 69% (0.84/0.48); OP_150 μm: 15% (0.53/0.004)). Similar failure modes were observed in HV and OP specimens. Radial cracks developing in the core and spreading into the veneer are suggested to cause bulk fracture, which is the characteristic failure mode for alumina core crowns. However, the highest resistance to fatigue loading was found for the HV specimens with thin cement thickness, while the lowest occurred for the OP with thick cement layer.

  14. Former US Ambassador’s Love for Chinese Porcelain

    Institute of Scientific and Technical Information of China (English)

    Xu; Nianrui

    2013-01-01

    <正>China’s Jingdezhen porcelain has long been well known and admired in the world. Among admirers, Arthur W. Hummel Jr., former US Ambassador to China, had a passionate love for blue and white "rice grain" porcelain. He was born in Fenyang in China’s western Shanxi Province in 1920. A church had sent his father, Arthur

  15. Porcelain Builds Bridges of Friendship Between Chinese and Dutch

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    <正>Porcelain is a major invention in ancient China. As early as in the Han Dynasty, the celadon ware was fired, which is as crystal and clear as jade. By the Tang Dynasty, the compact pure white porcelain was fired. Ceramics firing technology reached a mature stage.

  16. Porcelain three-dimensional shape reconstruction and its color reconstruction

    Science.gov (United States)

    Yu, Xiaoyang; Wu, Haibin; Yang, Xue; Yu, Shuang; Wang, Beiyi; Chen, Deyun

    2013-01-01

    In this paper, structured light three-dimensional measurement technology was used to reconstruct the porcelain shape, and further more the porcelain color was reconstructed. So the accurate reconstruction of the shape and color of porcelain was realized. Our shape measurement installation drawing is given. Because the porcelain surface is color complex and highly reflective, the binary Gray code encoding is used to reduce the influence of the porcelain surface. The color camera was employed to obtain the color of the porcelain surface. Then, the comprehensive reconstruction of the shape and color was realized in Java3D runtime environment. In the reconstruction process, the space point by point coloration method is proposed and achieved. Our coloration method ensures the pixel corresponding accuracy in both of shape and color aspects. The porcelain surface shape and color reconstruction experimental results completed by proposed method and our installation, show that: the depth range is 860 ˜ 980mm, the relative error of the shape measurement is less than 0.1%, the reconstructed color of the porcelain surface is real, refined and subtle, and has the same visual effect as the measured surface.

  17. Enameled Porcelain Bottle with Coral-Red Background

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    Decorative enameled porcelain was used by the imperial court during the reigns of Kangxi, Yongzheng and Qianlong of the Qing Dynasty. It was a new kind of art which blended French enameling skills with Chinese traditional porcelain craftsmanship. First made in the reign of Kangxi, the porcelainware decorated with the

  18. The effect of a light-emitting diode on shear bond strength of ceramic brackets bonded to feldspathic porcelain with different curing times.

    Science.gov (United States)

    Elekdag-Turk, Selma; Sarac, Y Sinasi; Turk, Tamer; Sarac, Duygu

    2007-06-01

    The aim of this study was to evaluate different curing times of a light-emitting diode (LED) unit on shear bond strength (SBS) of ceramic brackets bonded to feldspathic porcelain. Ceramic brackets were bonded with a light-cured adhesive to 96 feldspathic porcelain facets. Air-borne particle abrasion was performed using 25 mum aluminium trioxide (Al(2)O(3)) with an air abrasion device from a distance of approximately 10 mm at a pressure of 2.5 bars for 4 seconds, then the porcelain surfaces were etched with 9.6 per cent hydrofluoric acid for 2 minutes. After surface preparation of the porcelain specimens, silane was applied. In groups 1 and 2, the adhesive was cured with a quartz-tungsten-halogen (QTH) unit for 10 and 20 seconds, respectively. The LED was used in the standard mode for 3, 5, and 10 seconds for groups 3, 4, and 5, respectively. For the other three groups, the LED was used in the fast mode for 3, 5, and 10 seconds, respectively. The SBS of the brackets was measured on a universal testing machine. The adhesive remnant index (ARI) scores, damage to the porcelain, and fracture of the ceramic bracket bases were determined. No significant differences were observed for SBS between the eight groups (P=0.087). There was no significant difference between the groups' ARI scores, porcelain damage, and bracket base fracture (P=0.340, P=0.985, and P=0.340, respectively). There was a greater frequency of ARI scores of 0 for all groups. Fifty per cent of the porcelain facets displayed damage. Nineteen ceramic bracket base fractures were observed. No significant difference was found for the SBS of the groups with QTH and LED units and curing times. It is reliable to use LED with a 3-second curing time since it provided adequate bond strength for ceramic brackets bonded to porcelain surfaces.

  19. Effect of ZrN coating by magnetron sputtering and sol-gel processed silica coating on titanium/porcelain interface bond strength.

    Science.gov (United States)

    Xia, Yang; Zhou, Shu; Zhang, Feimin; Gu, Ning

    2011-02-01

    In this study, a coating technique was applied to improve the bond strength of titanium (Ti) porcelain. ZrN coating was prepared by magnetron sputtering, and silica coating was processed by a sol-gel method. The treated surfaces of the specimens were analyzed by X-ray diffraction, and the Ti/porcelain interface was investigated by scanning electron microscopy (SEM) and energy dispersive spectroscopy. The coated specimens appeared fully coherent to the Ti substrate. The fractured bonding surface was also investigated by SEM. The residual porcelain on the metal surface could be observed in the ZrN group and silica group, but there was no obvious porcelain remaining in the control group. A three-point-bending test showed that the bonding strength of the ZrN group (45.99 ± 0.65 MPa) was higher than the silica group (37.77 ± 0.78 MPa) (P coatings resulted in a stronger Ti/porcelain bond. ZrN coating by magnetron sputtering was a more effective way to improve the bond strength between Ti and porcelain compared with sol-gel processed silica coating in this study.

  20. ARTISTIC AND PRODUCTION FEATURES OF PORCELAIN SCULPTURE BY AUGUST SPIESS

    Directory of Open Access Journals (Sweden)

    Екатерина Сергеевна Хмельницкая

    2014-02-01

    Full Text Available The article deals with the identification and attribution of artistic production and features of porcelain sculpture created by the chief scultor of the Imperial Porcelain Factory in St. Petersburg August K. Spiess . Porcelain through creativity of Spies become so amazingly diverse, as it used to be in the XVIII century . Creative heritage of A. Spiess could be identified as a phenomenon that naturally associated with the broader social and cultural processes , typical for Russian art of the second half of the XIX century. However , in contrast to the next generation of sculptors , Spies activity does not go beyond the existence of porcelain production , and the sculptor has not sought to create works that can approve a porcelain sculpture in the eyes of a higher status.DOI: http://dx.doi.org/10.12731/2218-7405-2014-1-6

  1. 49 CFR 178.523 - Standards for composite packagings with inner glass, porcelain, or stoneware receptacles.

    Science.gov (United States)

    2010-10-01

    ... glass, porcelain, or stoneware receptacles. 178.523 Section 178.523 Transportation Other Regulations... Packaging Standards § 178.523 Standards for composite packagings with inner glass, porcelain, or stoneware... glass, porcelain, or stoneware: (1) 6PA1 for glass, porcelain, or stoneware receptacles within...

  2. The Porcelain Crab Transcriptome and PCAD, the Porcelain Crab Microarray and Sequence Database

    Energy Technology Data Exchange (ETDEWEB)

    Tagmount, Abderrahmane; Wang, Mei; Lindquist, Erika; Tanaka, Yoshihiro; Teranishi, Kristen S.; Sunagawa, Shinichi; Wong, Mike; Stillman, Jonathon H.

    2010-01-27

    Background: With the emergence of a completed genome sequence of the freshwater crustacean Daphnia pulex, construction of genomic-scale sequence databases for additional crustacean sequences are important for comparative genomics and annotation. Porcelain crabs, genus Petrolisthes, have been powerful crustacean models for environmental and evolutionary physiology with respect to thermal adaptation and understanding responses of marine organisms to climate change. Here, we present a large-scale EST sequencing and cDNA microarray database project for the porcelain crab Petrolisthes cinctipes. Methodology/Principal Findings: A set of ~;;30K unique sequences (UniSeqs) representing ~;;19K clusters were generated from ~;;98K high quality ESTs from a set of tissue specific non-normalized and mixed-tissue normalized cDNA libraries from the porcelain crab Petrolisthes cinctipes. Homology for each UniSeq was assessed using BLAST, InterProScan, GO and KEGG database searches. Approximately 66percent of the UniSeqs had homology in at least one of the databases. All EST and UniSeq sequences along with annotation results and coordinated cDNA microarray datasets have been made publicly accessible at the Porcelain Crab Array Database (PCAD), a feature-enriched version of the Stanford and Longhorn Array Databases.Conclusions/Significance: The EST project presented here represents the third largest sequencing effort for any crustacean, and the largest effort for any crab species. Our assembly and clustering results suggest that our porcelain crab EST data set is equally diverse to the much larger EST set generated in the Daphnia pulex genome sequencing project, and thus will be an important resource to the Daphnia research community. Our homology results support the pancrustacea hypothesis and suggest that Malacostraca may be ancestral to Branchiopoda and Hexapoda. Our results also suggest that our cDNA microarrays cover as much of the transcriptome as can reasonably be captured in

  3. Anodization process produces opaque, reflective coatings on aluminum

    Science.gov (United States)

    1965-01-01

    Opaque, reflective coatings are produced on aluminum articles by an anodizing process wherein the anodizing bath contains an aqueous dispersion of finely divided insoluble inorganic compounds. These particles appear as uniformly distributed occlusions in the anodic deposit on the aluminum.

  4. Nonlinear visco-elastic finite element analysis of different porcelain veneers configuration.

    Science.gov (United States)

    Sorrentino, Roberto; Apicella, Davide; Riccio, Carlo; Gherlone, Enrico; Zarone, Fernando; Aversa, Raffaella; Garcia-Godoy, Franklin; Ferrari, Marco; Apicella, Antonio

    2009-11-01

    This study is aimed at evaluating the biomechanical behavior of feldspathic versus alumina porcelain veneers. A 3D numerical model of a maxillary central incisor, with the periodontal ligament (PDL) and the alveolar bone was generated. Such model was made up of four main volumes: dentin, enamel, cement layer and veneer. Incisors restored with alumina and feldspathic porcelain veneers were compared with a natural sound tooth (control). Enamel, cementum, cancellous and cortical bone were considered as isotropic elastic materials; on the contrary, the tubular structure of dentin was designed as elastic orthotropic. The nonlinear visco-elatic behavior of the PDL was considered. The veneer volumes were coupled with alumina and feldspathic porcelain mechanical properties. The adhesive layers were modeled in the FE environment using spring elements. A 50N load applied at 60 degrees angle with tooth longitudinal axis was applied and validated. Compressive stresses were concentrated on the external surface of the buccal side of the veneer close to the incisal margin; such phenomenon was more evident in the presence of alumina. Tensile stresses were negligible when compared to compressive ones. Alumina and feldspathic ceramic were characterized by a different biomechanical behavior in terms of elastic deformations and stress distributions. The ultimate strength of both materials was not overcome in the performed analysis.

  5. Comparison of the Effect of Nd:YAG Laser and Sandblasting on Shear Bond Strength of a Commercial Ni-Cr Alloy to Porcelain

    Directory of Open Access Journals (Sweden)

    Elnaz Moslehifard

    2016-09-01

    Full Text Available Introduction: Failures might occur at metal‒porcelain interfaces as a problem with metal‒ceramic restorations even with the application of airborne-particle abrasion technique. This study was undertaken to evaluate the effect of Nd:YAG laser treatment on the bond strength of porcelain fused to metal. Methods:  Twenty-four cylindrical specimens (4 mm in diameter and 4 mm in height were made of a commercially available nickel‒chromium alloy by lost-wax technique. Half of the specimens were surface-treated by air-borne particles and the other half was irradiated with Nd:YAG laser beams (wavelength of 1064 nm, energy and frequency of 120 mJ and 10 Hz, respectively, and a power setting of 6 kW. All the specimens (air-abraded and laser-treated were covered with a 4-mm layer of opaque porcelain in two-stage baking and subjected to shear bond strength test (a 10-kgf at 1 mm/min until fracture occurred. A fractured specimen from each group was evaluated using scanning electron microscopy. T-test was used for statistical analysis and statistical significance was set at P

  6. A.K. SPIESS. LIFE, DEVOTED TO PORCELAIN

    Directory of Open Access Journals (Sweden)

    Екатерина Сергеевна Хмельницкая

    2014-02-01

    Full Text Available The article reconstructs the creative biography of the sculptor of the Imperial Porcelain Factory A.K. Spiess, development of his career in Russia. Over the 47 years he was the Chief sculptor of the porcelain factory and was the author of most of the figures created during the "historicism." The article investigates his creative activity, historical and cultural conditions of the development of the porcelain sculpture under his leadership. The author examines in detail the identity of the sculptor, the evolution of his creative activity, discusses the key factors in the development of his career. After four years after arriving in Russia, a former student and assistant sculptor received a position of the chief sculptor of the Imperial Porcelain Factory. Spies managed to perfectly flatter the taste of the Empress Maria, skillfully using the latest achievements of porcelain production, sculptor borrowed from Europe. Due to the great diversity of Spies, it should be noted porcelain amazing adaptability to any changes in the art of Historicism, where one style of fashion rapidly replaced by others. Porcelain Spies "successfully coped with any role": central interior decoration, household items, personal preferences, or evidence of the imperial status of the owner. Author concludes that the "secret" so successful creative activity of August Spiess, who for decades defined the artistic policy sculpture department, consists in the fact that his art was not just on time and responded to the artistic needs of the society. "From porcelain man can do everything" - said I.-I. Candler, whom Europe obliged the birth of porcelain. This phrase is also the key to the art of A. K Spiess.DOI: http://dx.doi.org/10.12731/2218-7405-2014-1-5

  7. Porcelain Product Quality Analysis in PT XYZ

    Directory of Open Access Journals (Sweden)

    Ho Hwi Chie

    2015-12-01

    Full Text Available PT. XYZ is a company engaged in manufacturing porcelain dinner ware such as plates, cups, teapot, bowl, etc Porcelain product is safe for use and product defect will only affect the aesthetic not the functional side. The company always maintain the quality of the products produced as by maintaining a good product, in terms of visuals, will keep customers interested in the product. Good quality products characterized by quality A / B and C, and the product defect characterized by the quality of D, Lost, and BU. Concepts and methods used to analyze is a statistical process control (SPC which includes Pareto diagram, fraction nonconformities, flow charts and fishbone diagrams and management tools (fault tree analysis. Statistical Process Control (SPC is one of the methods, which includes Pareto charts, fraction nonconformities, flow chart, and fishbone diagram and also management tools (fault tree analysis. SPC is useful to find the facts from the problems and factors that affect the quality of the products, while fault tree analysis is useful to analyze each of the production process.

  8. Anorthite porcelain: synthesis, phase and microstructural evolution

    Indian Academy of Sciences (India)

    Mousumi Pal; Sukhen Das; Swapan Kumar Das

    2015-04-01

    In the present study, anorthite (CaAl2Si2O8) porcelain was fabricated using Ca(OH)2, Al(OH)3, quartz, aluminous cement and feldspar as raw materials. Two compositions were formulated (coded as CAQ and CFQ)and their physico-mechanical properties (%AP, BD, flexural strength) were studied and compared. CAQ (21.2 wt% Ca(OH)2, 44.5 wt% Al(OH)3 and 34.3 wt% quartz) shows very poor densification and strength even after heating at 1450° C, although anorthite formation is observed on heating it at various temperatures. On the other hand, CFQ (48.6 wt% aluminous cement, 29.37 wt% feldspar and 22.06 wt% quartz) achieved full densification and superior strength at 1450° C with more anorthite formation compared to CAQ. X-ray diffraction and scanning electron microscope studies were also carried out to analyse the phase and microstructure evolution. The coefficient of thermal expansion of the anorthite-based sample was found to be lower than quartz and mullite porcelain which suggests its application as cooking ware.

  9. Porcelain Product Quality Analysis in PT XYZ

    Directory of Open Access Journals (Sweden)

    Ho Hwi Chie

    2015-12-01

    Full Text Available PT. XYZ is a company engaged in manufacturing porcelain dinner ware such as plates, cups, teapot, bowl, etc Porcelain product is safe for use and product defect will only affect the aesthetic not the functional side. The company always maintain the quality of the products produced as by maintaining a good product, in terms of visuals, will keep customers interested in the product. Good quality products characterized by quality A / B and C, and the product defect characterized by the quality of D, Lost, and BU. Concepts and methods used to analyze is a statistical process control (SPC which includes Pareto diagram, fraction nonconformities, flow charts and fishbone diagrams and management tools (fault tree analysis. Statistical Process Control (SPC is one of the methods, which includes Pareto charts, fraction nonconformities, flow chart, and fishbone diagram and also management tools (fault tree analysis. SPC is useful to find the facts from the problems and factors that affect the quality of the products, while fault tree analysis is useful to analyze each of the production process.

  10. Sub-Nyquist sampling boosts targeted light transport through opaque scattering media

    CERN Document Server

    Shen, Yuecheng; Ma, Cheng; Wang, Lihong V

    2016-01-01

    Optical time-reversal techniques are being actively developed to focus light through or inside opaque scattering media. When applied to biological tissue, these techniques promise to revolutionize biophotonics by enabling deep-tissue non-invasive optical imaging, optogenetics, optical tweezers and photodynamic therapy. In all previous optical time-reversal experiments, the scattered light field was well-sampled during wavefront measurement and wavefront reconstruction, following the Nyquist sampling criterion. Here, we overturn this conventional practice by demonstrating that even when the scattered field is under-sampled, light can still be focused through or inside opaque media. Even more surprisingly, we show both theoretically and experimentally that the focus achieved by under-sampling is usually about one order of magnitude brighter than that achieved by conventional well-sampling conditions. Moreover, sub-Nyquist sampling improves the signal-to-noise ratio and the collection efficiency of the scattered...

  11. The Effects of Opaque and Clear Pit and Fissure Sealants on Infrared Laser Fluorescence Measurements

    Science.gov (United States)

    Bahrololoomi, Z.; Khodabakhsh, M.; Khaksar, Y.

    2014-01-01

    Statement of the Problem: The purpose of placing sealants is to inhibit caries by physical closure of the pits and fissures of teeth. A device named DIAGNOdent is useful in detecting occlusal caries by employing laser fluorescence (LF). However, there are contradictory results in the influence of sealants on LF measurements. Purpose: The aim of this study is to investigate the effects of two different types of fissure sealants on LF measurements. Materials and Method: In this in vitro study, 86 extracted permanent third molars were divided randomly into two groups and clear or opaque sealant was applied on the occlusal surfaces. Two examiners performed pre- and post-seal fluorescence measurements twice with one week interval by employing DIAGNOdent device. Finally, measured values were evaluated through the statistical paired t-test by means of SPSS 17 software. Results: The mean value of LF measurements increased significantly due to the application of clear sealant (p= 0.001) while the statistical changes in this measurement was negligible after applying opaque sealant (p= 0.311). Conclusion: Clear sealants increase the LF measured values but opaque sealants cause almost no changes. Therefore, DIAGNOdent device is not reliable for detecting caries beneath the clear sealant. PMID:24883342

  12. The Effects of Opaque and Clear Pit and Fissure Sealants on Infrared Laser Fluorescence Measurements

    Directory of Open Access Journals (Sweden)

    Bahrololoomi Z.

    2013-10-01

    Full Text Available Statement of the Problem: The purpose of placing sealants is to inhibit caries by physical closure of the pits and fissures of teeth. A device named DIAGNOdent is useful in detecting occlusal caries by employing laser fluorescence (LF. However, there are contradictory results in the influence of sealants on LF measurements. Purpose: The aim of this study is to investigate the effects of two different types of fissure sealants on LF measurements. Materials and Method: In this in vitro study, 86 extracted permanent third molars were divided randomly into two groups and clear or opaque sealant was applied on the occlusal surfaces. Two examiners performed pre and post-seal fluorescence measurements twice with one week interval by employing DIAGNOdent device. Finally, measured values were evaluated through the statistical paired t-test by means of SPSS 17 software. Results: The mean value of LF measurements increased significantly due to the application of clear sealant (p= 0.001 while the statistical changes in this measurement is negligible after applying opaque sealant (p= 0.311. Conclusion: Clear sealants increase the LF measured values but opaque sealants cause almost no changes. Therefore DIAGNOdent device is not reliable for detecting caries beneath the clear sealant.

  13. PORCELAIN LAMINATE VENEERS: A MINIMALLY INVASIVE ESTHETIC PROCEDURE

    Directory of Open Access Journals (Sweden)

    Tajammul

    2013-11-01

    Full Text Available ABSTRACT: With the advancement in the area of cosmetic dentistry, the dental profession has been offered new opportunities in conservative and esthetic restorative procedures. Multiple options are available to treat problems arising in the zone of high esthetic sensitivity. The use of porcelain laminate veneers to solve esthetic and/or functional problems has shown to be a valid treatment option especially in the anterior esthetic zone. The techniques and the materials employed to fabricate porcelain laminate veneers offer satisfactory, predictable and lasting results. The current porcelain veneers are esthetically superior, conservative and durable treatment modality

  14. [Clinical analysis of laser welding on porcelain bonded metal surface].

    Science.gov (United States)

    Weng, Jia-wei; Dai, Wen-an; Wu, Xue-ying

    2011-02-01

    To evaluate the clinical effect of laser-welded crowns and bridges. Two hundred defective crowns and bridges were welded by using Heraplus laser welding machine, and then restored by porcelain. After being welded ,those defective crowns and bridges of different materials fit well and their marginal areas were also satisfactory. During the follow up period of one year, no fractured porcelain and crack were found at welding spots. The technology of laser welding has no direct effect on welding spots between metal and porcelain and could be used to deal with the usual problems of the crowns and bridges.

  15. Indirect porcelain veneer technique for restoring intrinsically stained teeth.

    Science.gov (United States)

    Cutbirth, S T

    1992-01-01

    Indirect porcelain veneers are often the ideal restoration for intrinsically stained teeth. This article details a step-by-step procedure for esthetically restoring discolored teeth. Porcelain laminate veneers are often indicated when teeth bleaching or direct composite bonding procedures cannot provide the desired esthetic result. Veneers are more appealing to many patients than full coverage crowns because of the more conservative tooth preparation required. If technique details are followed meticulously and cases are appropriately selected, porcelain veneers are not only durable but also promote marvelous gingival health and may be the most esthetic anterior dental restoration.

  16. Effect of Repeated Firings of Porcelain on Bond Strength of Two Base Metal Alloys

    Directory of Open Access Journals (Sweden)

    Gerami Panah F

    2001-05-01

    Full Text Available The formation of oxides on the surface of the metal are proven to contribute to the formation of strong bonding. However, The base metal alloys are expected to exhibit more oxidation than high gold alloys, increase in oxide layer thickness due to repeated firing in them can reduce the bond strength. The aim of this study was to compare the effect of repeated porcelain firing on the bond strength of two base metal alloys (Minalux and Verabond II. Sixteen metal plates (20x5x0.5 from each alloy were cast and prepared according to the manufacturers' instruction. Porcelain with uniform thickness (Imm was applied on the middle one third of metal plates. After this stage, each alloy group divided to three subgroups. Group I was fired for the second time to form the final glaze, group II and III were fired two and four more times respectively. Specimens were subjected to 3-point flexural test in a digital tritest machine. Results showed no significant differences between bond strength of two alloys. Also results showed repeated firing had no significant effect on bond strength. Due to these findings, this study support similarity of two alloys (Minalux and Verabond II in their bond strength with porcelain.

  17. Marginal integrity of two zirconia-based crowns before and after porcelain veneering

    Directory of Open Access Journals (Sweden)

    Sakineh Nikzad

    2013-04-01

    Full Text Available Background and Aims: The marginal integrity of fixed restorations always is a major matter of concern for dental clinicians. Any cause of distortion, including veneering processes, in the marginal integrity is supposed to be detrimental for long-term success of fixed dental prostheses. The aim of this in vitro study was to compare the marginal adaptation of two different full ceramic restoration systems (Zirkouzahu&Cercon and possible changes in marginal integrity following the multiple veneering process. Materials and Methods: Twelve all-ceramic crowns in the form of coping were fabricated on a pre-made standard metal die with finish line of shoulder preparation from two commercial systems: Cercon® and Zirkonzahn®. The specimens were not cemented. The Crown/Die discrepancy were measured by means of a precise stereo microscope (accuracy±0.1 μm, at various points (n=12 selected along circumferential margin of the restorations. Same procedure was accomplished after applying the veneering porcelain. The mean gap dimensions were calculated and data were analyzed by multivariate (b test. Results: Mean marginal gap dimensions before and after veneering porcelain firing cycles, for Cercon® were (59.67±13.46 µm and (63.75±14.16 µm and for Zirkonzahn® were (65.81±24.37 µm and (64.74±21.94 µm, respectively. Hotelling trace Multivariate(b test method showed that the rate of mismatching marginal integrity in two groups (Cercon® and Zirkonzahn® had no significant difference before and after porcelain firing (P>0.05. Conclusion: Within the limitation of this study, the marginal integrity of both systems were seems to be within the clinically acceptable standard dimension, i.e. 120μm.The marginal gap of both all-ceramic systems were not affected by veneering porcelain firing cycles.

  18. The unbearable opaqueness of Arp220

    Science.gov (United States)

    Martín, S.; Aalto, S.; Sakamoto, K.; González-Alfonso, E.; Muller, S.; Henkel, C.; García-Burillo, S.; Aladro, R.; Costagliola, F.; Harada, N.; Krips, M.; Martín-Pintado, J.; Mühle, S.; van der Werf, P.; Viti, S.

    2016-05-01

    Context. The origin of the enormous luminosities of the two opaque nuclei of Arp 220, the prototypical ultra-luminous infrared galaxy, remains a mystery because we lack observational tools to explore the innermost regions around the nuclei. Aims: We explore the potential of imaging vibrationally excited molecular emission at high angular resolution to better understand the morphology and physical structure of the dense gas in Arp 220 and to gain insight into the nature of the nuclear powering sources. Methods: The Atacama Large Millimeter/submillimeter Array (ALMA) provided simultaneous observations of HCN, HCO+, and vibrationally excited HCN v2 = 1f emission. Their J = 4-3 and 3-2 transitions were observed at a matching resolution of ~0.5'', which allows us to isolate the emission from the two nuclei. Results: The HCN and HCO+ lines within the ground-vibrational state poorly describe the central ~100 pc region around the nuclei because there are strong effects of cool absorbing gas in the foreground and severe line blending that is due to the prolific molecular emission of Arp 220. Vibrationally excited emission of HCN is detected in both nuclei with a very high ratio relative to the total LFIR, higher than in any other observed galaxy and well above what is observed in Galactic hot cores. HCN v2 = 1f is observed to be marginally resolved in ~60 × 50 pc regions inside the dusty ~100 pc sized nuclear cores. Its emission is centered on our derived individual nuclear velocities based on HCO+ emission (VWN = 5342 ± 4 and VEN = 5454 ± 8 km s-1, for the western and eastern nucleus, respectively). With virial masses within r ~ 25-30 pc based on the HCN v2 = 1f line widths, we estimate gas surface densities (gas fraction fg = 0.1) of 3 ± 0.3 × 104 M⊙ pc-2 (WN) and 1.1 ± 0.1 × 104 M⊙ pc-2 (EN). The 4-3/3-2 flux density ratio could be consistent with optically thick emission, which would further constrain the size of the emitting region to >15 pc (EN) and >22 pc

  19. Porcelain tiles by the dry route

    Directory of Open Access Journals (Sweden)

    Boschi, A. O.

    2010-10-01

    Full Text Available In Brazil, the second largest tile producer of the world, at present, 70% of the tiles are produced by the dry route. One of the main reasons that lead to this development is the fact that the dry route uses approximately 30% less thermal energy them the traditional wet route. The increasing world concern with the environment and the recognition of the central role played by the water also has pointed towards privileging dry processes. In this context the objective of the present work is to study the feasibility of producing high quality porcelain tiles by the dry route. A brief comparison of the dry and wet route, in standard conditions industrially used today to produce tiles that are not porcelain tiles, shows that there are two major differences: the particle sizes obtained by the wet route are usually considerably finer and the capability of mixing the different minerals, the intimacy of the mixture, is also usually better in the wet route. The present work studied the relative importance of these differences and looked for raw materials and operational conditions that would result in better performance and glazed porcelain tiles of good quality.

    En Brasil, en este momento segundo productor mundial, el 70% de los pavimentos cerámicos se obtiene por vía seca. Una de las razones fundamentales se debe a que esta vía supone un consumo energético inferior, en un 30%, a la via húmeda tradicional. La creciente preocupación mundial sobre los problemas medioambientales y el reconocimiento del papel central que juega el agua en este proceso han favorecido el desarrollo de la vía seca. En este contexto, el objetivo del presente trabajo es estudiar la viabilidad de la producción de pavimentos porcelánicos de alta calidad por vía seca. Una breve comparación entre ambas vías, en las condiciones standard de producción vigentes para producciones que no son de porcelánico, indican que existen dos diferencias substanciales; el tamaño de

  20. Tin oxide coating of aluminous porcelain by reactive ion plating.

    Science.gov (United States)

    McCrory, P V; Tinston, S; Piddock, V; Kelly, P; Combe, E C; Arnell, R D

    1991-06-01

    Alumina reinforced dental porcelain has been coated directly with tin oxide by reactive ion plating. Samples were prepared at different distances from the tin source in the ion plating rig. Tensile bond strengths of treated and untreated porcelain discs to a commercially available phosphate-methacrylate based dental cement were determined. Bond strengths of certain coated samples were found to be in excess of the cohesive strength of the porcelain substrates (greater than 7.8 MPa), whereas untreated porcelain achieved an average bond strength of only 3.4 MPa. The microstructures of coatings produced under conditions similar to those which yielded the maximum bond strength were examined in a scanning electron microscope and were found to be approximately 0.5 microns thick. It is believed that ion plating has great potential for rendering inert ceramic surfaces capable of direct bonding to dental cements.

  1. influence of addition of rice husk ash on porcelain composition

    African Journals Online (AJOL)

    Porcelain powder was grounded separately in a ball mill. The powder was sieved using ... The mixed powder .... combustion at 7000C produces a very good reactive material. The .... rice husk-berk ash on mechanical properties of of concrete.

  2. Rapid porcelain veneers: smile design, preparation, and cementation.

    Science.gov (United States)

    Javaheri, D S

    2001-11-01

    A technique for replacing existing porcelain veneers has been presented. Technique for smile design, tooth preparation, and cementation were described. The objective was to meet the patient's aesthetic expectations while also meeting functional requirements.

  3. Sexual Biofilm Formation in Candida tropicalis Opaque Cells

    Science.gov (United States)

    Jones, Stephen K.; Hirakawa, Matthew P.; Bennett, Richard J.

    2014-01-01

    Summary Candida albicans and Candida tropicalis are opportunistic fungal pathogens that can transition between white and opaque phenotypic states. White and opaque cells differ both morphologically and in their responses to environmental signals. In C. albicans, opaque cells respond to sexual pheromones by undergoing conjugation, while white cells are induced by pheromones to form sexual biofilms. Here, we show that sexual biofilm formation also occurs in C. tropicalis but, unlike C. albicans, biofilms are formed exclusively by opaque cells. C. tropicalis biofilm formation was dependent on the pheromone receptors Ste2 and Ste3, confirming the role of pheromone signaling in sexual biofilm development. Structural analysis of C. tropicalis sexual biofilms revealed stratified communities consisting of a basal layer of yeast cells and an upper layer of filamentous cells, together with an extracellular matrix. Transcriptional profiling showed that genes involved in pheromone signaling and conjugation were upregulated in sexual biofilms. Furthermore, FGR23, which encodes an agglutinin-like protein, was found to enhance both mating and sexual biofilm formation. Together, these studies reveal that C. tropicalis opaque cells form sexual biofilms with a complex architecture, and suggest a conserved role for sexual agglutinins in mediating mating, cell cohesion and biofilm formation. PMID:24612417

  4. Cyclic testing of porcelain laminiate veneers on superficial enamel and dentin: Pressed vs. conventional layered porcelain

    Science.gov (United States)

    Tawde, Shweta

    Statement of Problem: Clinicians are inclined towards more aggressive teeth preparations to accommodate the thickness of the veneering material. The principle of conservative tooth preparation is compromised. Purpose: By using a conservative approach to treatment with porcelain veneers, long-lasting, esthetic and functional results may be achieved. Sacrificing as little tooth structure as possible and conserving the supporting tissues will facilitate prospective patients. Materials and Methods: Forty extracted human maxillary and mandibular canines were selected. The teeth were divided into one of two groups (pressable and stackable) and further subdivided according to tooth substrate (all-enamel or mixed enamel-dentin exposure). Twenty canine teeth were allotted to the pressable veneer group and 20 were allotted to the stackable veneer group. Of the 20 teeth in the pressable group, all were pressed with a lithium disilicate ceramic system (IPS e.max Press), 10 with labial tooth reduction of 0.3-0.5 mm maintaining superficial enamel (PEN) and the remaining 10 teeth with labial veneer reduction of 0.8-1.0 mm exposing superficial dentin (PDN). Of the 20 teeth in the stackable group, all were stacked/ layered with conventional feldspathic porcelain (Fortune; Williams/ Ivoclar); with labial veneer reduction of 0.3-0.5 mm maintaining superficial enamel (SEN) and the remaining 10 teeth with labial veneer reduction of 0.8-1.0 mm exposing superficial dentin (SDN). Silicon putty matrix was fabricated prior to teeth preparation to estimate the teeth reduction. The prepared facial reduction was limited to the incisal edge. No incisal or palatal/lingual reduction was performed. Impressions of the prepared teeth were taken in medium/light-bodied PVS. Master casts were made in Resin Rock. The stackable group specimens were made with fabricating refractory dies and after following the recommended steps of laboratory procedure, stackable veneers were processed. The pressable group

  5. Porcelain laminate veneers: Clinical survey for evaluation of failure

    OpenAIRE

    Diemah F Alhekeir; Al-Sarhan, Rana A.; Al Mashaan, Abdulmohsen F.

    2014-01-01

    Objective: To investigate the association of the failure of porcelain laminate veneers with factors related to the patient, material, and operator. Methods: This clinical survey involved 29 patients (19 women and 10 men) and their dentists, including undergraduate and postgraduate dental students and dental interns. Two questionnaires were distributed to collect information from participants. All patients were clinically examined. Criteria for failure of the porcelain laminate veneers incl...

  6. Noninvasive detection of concealed explosives: depth profiling through opaque plastics by time-resolved Raman spectroscopy.

    Science.gov (United States)

    Petterson, Ingeborg E Iping; López-López, María; García-Ruiz, Carmen; Gooijer, Cees; Buijs, Joost B; Ariese, Freek

    2011-11-15

    The detection of explosives concealed behind opaque, diffusely scattering materials is a challenge that requires noninvasive analytical techniques for identification without having to manipulate the package. In this context, this study focuses on the application of time-resolved Raman spectroscopy (TRRS) with a picosecond pulsed laser and an intensified charge-coupled device (ICCD) detector for the noninvasive identification of explosive materials through several millimeters of opaque polymers or plastic packaging materials. By means of a short (250 ps) gate which can be delayed several hundred picoseconds after the laser pulse, the ICCD detector allows for the temporal discrimination between photons from the surface of a sample and those from deeper layers. TRRS was applied for the detection of the two main isomers of dinitrotoluene, 2,4-dinitrotoluene, and 2,6-dinitrotoluene as well as for various other components of explosive mixtures, including akardite II, diphenylamine, and ethyl centralite. Spectra were obtained through different diffuse scattering white polymer materials: polytetrafluoroethylene (PTFE), polyoxymethylene (POM), and polyethylene (PE). Common packaging materials of various thicknesses were also selected, including polystyrene (PS) and polyvinyl chloride (PVC). With the demonstration of the ability to detect concealed, explosives-related compounds through an opaque first layer, this study may have important applications in the security and forensic fields.

  7. The porcelain crab transcriptome and PCAD, the porcelain crab microarray and sequence database.

    Directory of Open Access Journals (Sweden)

    Abderrahmane Tagmount

    Full Text Available BACKGROUND: With the emergence of a completed genome sequence of the freshwater crustacean Daphnia pulex, construction of genomic-scale sequence databases for additional crustacean sequences are important for comparative genomics and annotation. Porcelain crabs, genus Petrolisthes, have been powerful crustacean models for environmental and evolutionary physiology with respect to thermal adaptation and understanding responses of marine organisms to climate change. Here, we present a large-scale EST sequencing and cDNA microarray database project for the porcelain crab Petrolisthes cinctipes. METHODOLOGY/PRINCIPAL FINDINGS: A set of approximately 30K unique sequences (UniSeqs representing approximately 19K clusters were generated from approximately 98K high quality ESTs from a set of tissue specific non-normalized and mixed-tissue normalized cDNA libraries from the porcelain crab Petrolisthes cinctipes. Homology for each UniSeq was assessed using BLAST, InterProScan, GO and KEGG database searches. Approximately 66% of the UniSeqs had homology in at least one of the databases. All EST and UniSeq sequences along with annotation results and coordinated cDNA microarray datasets have been made publicly accessible at the Porcelain Crab Array Database (PCAD, a feature-enriched version of the Stanford and Longhorn Array Databases. CONCLUSIONS/SIGNIFICANCE: The EST project presented here represents the third largest sequencing effort for any crustacean, and the largest effort for any crab species. Our assembly and clustering results suggest that our porcelain crab EST data set is equally diverse to the much larger EST set generated in the Daphnia pulex genome sequencing project, and thus will be an important resource to the Daphnia research community. Our homology results support the pancrustacea hypothesis and suggest that Malacostraca may be ancestral to Branchiopoda and Hexapoda. Our results also suggest that our cDNA microarrays cover as much of the

  8. PREPARATION OF HIGH THERMAL EXPANSION COEFFICIENT PORCELAINS FUSED TO METALS

    Institute of Scientific and Technical Information of China (English)

    J.P. Yang; J.Q. Wu

    2003-01-01

    Usually the thermal expansion coefficients (TEC) of metals are higher than that of porcelains. In order to match the TECs in the case of coating porcelains on metals, high TEC porcelains are needed. In this research, the high TEC phase leucite(KAlSi2 O6) in the high TEC porcelain was prepared by sol-gel method. The crystal size of leucite made by sol-gel is about 77nm through controlling the process parameters. The process from xerogel to leucite was investigated by means of DSC (differential scanning calorimetry), TG (thermogravimetry), XRD ( X-ray diffraction) and IR(infrared absorption spectrum). Leucite had been detected after the gel was treated at 900°C, this formation temperature is about 250°C lower than that of melting method.The porcelain made from 50% of the leucite powder and 50%o of low fused temperature frit has an average TEC of 19.2× 10-6/° C from room temperature to 450°C, which is much higher than the common porcelains.

  9. Effect of the Thickess on Color of Porcelain Laminate Veneer

    Institute of Scientific and Technical Information of China (English)

    陆支越; 章非敏; 殷新民

    2003-01-01

    Objective :To evaluale the color change of the two-layer porcelain laminate veneer after adding veneering porcelain of differeat thickness to the 0.2mm thick aluminum oxide.Methods:Ten alumium axide disks were randomized into 2 groups.Each of five disks was veneered with Vita Lumin Shade B4 porcelain of thickness of 0.4mm and 0.6mm respectively.The L*a*b* color notations of the substrate covered with non-veneered disks and 2 thickness porcelain veneered disks were measured separtely and the color differences(ΔE) were calculated.Results:Statistically significant differences in color coordinates of dark substrates were recorded after the sustrate was covered by an aluminum oxide disk and also after the addition of veneering porcelain to the alumimum axide disks in group 1(P=0.0002) and group 2(P=0.0075) and between 2 groups(P=0.0001).Conclusion:The ability of masking underlying discoloration was increased and shifted to gray when the thickness of veneering porcelain increased.

  10. Investigation of the time-dependent wear behavior of veneering ceramic in porcelain fused to metal crowns during chewing simulations.

    Science.gov (United States)

    Guo, Jiawen; Tian, Beimin; Wei, Ran; Wang, Weiguo; Zhang, Hongyun; Wu, Xiaohong; He, Lin; Zhang, Shaofeng

    2014-12-01

    The excessive abrasion of occlusal surfaces in ceramic crowns limits the service life of restorations and their clinical results. However, little is known about the time-dependent wear behavior of ceramic restorations during the chewing process. The aim of this in vitro study was to investigate the dynamic evolution of the wear behavior of veneering porcelain in PFM crowns as wear progressed, as tested in a chewing simulator. Twenty anatomical metal-ceramic crowns were prepared using Ceramco III as the veneering porcelain. Stainless steel balls served as antagonists. The specimens were dynamically loaded in a chewing simulator with 350N up to 2.4×10(6) loading cycles, with additional thermal cycling between 5 and 55°C. During the testing, several checkpoints were applied to measure the substance loss of the crowns' occlusal surfaces and to evaluate the microstructure of the worn areas. After 2.4×10(6) cycles, the entire wear process of the veneering porcelain in the PFM crowns revealed three wear stages (running-in, steady and severe wear stages). The occlusal surfaces showed traces of intensive wear on the worn areas during the running-in wear stage, and they exhibited the propagation of cracks in the subsurface during steady wear stage. When the severe wear stage was reached, the cracks penetrated the ceramic layer, causing the separation of porcelain pieces. It also exhibited a good correlation among the microstructure, the wear loss and the wear rate of worn ceramic restorations. The results suggest that under the conditions of simulated masticatory movement, the wear performance of the veneering porcelain in PFM crowns indicates the apparent similarity of the tribological characteristics of the traditional mechanical system. Additionally, the evaluation of the wear behavior of ceramic restorations should be based on these three wear stages.

  11. Advanced tomographic flow diagnostics for opaque multiphase fluids

    Energy Technology Data Exchange (ETDEWEB)

    Torczynski, J.R.; O`Hern, T.J.; Adkins, D.R.; Jackson, N.B.; Shollenberger, K.A.

    1997-05-01

    This report documents the work performed for the ``Advanced Tomographic Flow Diagnostics for Opaque Multiphase Fluids`` LDRD (Laboratory-Directed Research and Development) project and is presented as the fulfillment of the LDRD reporting requirement. Dispersed multiphase flows, particularly gas-liquid flows, are industrially important to the chemical and applied-energy industries, where bubble-column reactors are employed for chemical synthesis and waste treatment. Due to the large range of length scales (10{sup {minus}6}-10{sup 1}m) inherent in real systems, direct numerical simulation is not possible at present, so computational simulations are forced to use models of subgrid-scale processes, the accuracy of which strongly impacts simulation fidelity. The development and validation of such subgrid-scale models requires data sets at representative conditions. The ideal measurement techniques would provide spatially and temporally resolved full-field measurements of the distributions of all phases, their velocity fields, and additional associated quantities such as pressure and temperature. No technique or set of techniques is known that satisfies this requirement. In this study, efforts are focused on characterizing the spatial distribution of the phases in two-phase gas-liquid flow and in three-phase gas-liquid-solid flow. Due to its industrial importance, the bubble-column geometry is selected for diagnostics development and assessment. Two bubble-column testbeds are utilized: one at laboratory scale and one close to industrial scale. Several techniques for measuring the phase distributions at conditions of industrial interest are examined: level-rise measurements, differential-pressure measurements, bulk electrical impedance measurements, electrical bubble probes, x-ray tomography, gamma-densitometry tomography, and electrical impedance tomography.

  12. Development of porcelain enamel passive thermal control coatings

    Science.gov (United States)

    Levin, H.; Lent, W. E.; Buettner, D. H.

    1973-01-01

    A white porcelain enamel coating was developed for application to high temperature metallic alloy substrates on spacecraft. The coating consists of an optically opacifying zirconia pigment, a lithia-zirconia-silica frit, and an inorganic pigment dispersant. The coating is fired at 1000 to 1150 C to form the enamel. The coating has a solar absorptance of 0.22 and a total normal emittance of 0.82 for a 0.017 cm thick coating. The coating exhibits excellent adhesion, cleanability, and integrity and is thermal shock resistant to 900 C. Capability to coat large panels has been demonstrated by successful coating of 30 cm x 30 cm Hastelloy X alloy panels. Preliminary development of low temperature enamels for application to aluminum and titanium alloy substrates was initiated. It was determined that both leaded and leadless frits were feasible when applied with appropriate mill fluxes. Indications were that opacification could be achieved at firing temperatures below 540 C for extended periods of time.

  13. Experimental Analysis and Model Validation of an Opaque Ventilated Facade

    DEFF Research Database (Denmark)

    López, F. Peci; Jensen, Rasmus Lund; Heiselberg, Per

    2012-01-01

    Natural ventilation is a convenient way of reducing energy consumption in buildings. In this study an experimental module of an opaque ventilated façade (OVF) was built and tested for assessing its potential of supplying free ventilation and air preheating for the building. A numerical model was ...

  14. Opaque Contact Lens For Tracking Motion Of Eye

    Science.gov (United States)

    Zografos, James L., II; Gibson, Charles R.

    1993-01-01

    Opaque contact lens facilitates measurements of movements of eye; particularly, torsional movements. Lens, marked with pair of indices at diameter of 0.5 mm, provides stable, high-contrast reference for measurements of angular position and velocity of eye by use of video-image-analysis techniques. Intended for use in experiments on response of eye to vestibular balance mechanism.

  15. Effect of thermocycling on the flexural strength of porcelain laminate veneers

    OpenAIRE

    Subramanian Deepa; Sivagami G; Sendhilnathan D; Rajmohan C

    2008-01-01

    Aim: The aim of this study was to examine the impact of thermocycling on the flexural strength and development of surface flaws on the glazed surface of porcelain laminate veneer restorations with and without resin luting cement. Materials and Methods: 80 Vitadur alpha dentin porcelain discs (10 mm diameter, 0.9 mm thickness) were glazed on one side and divided into two groups: A (porcelain laminate veneer only without resin luting cement) and B (porcelain laminate veneer luted with resin ce...

  16. Bond strength of the porcelain repair system to all-ceramic copings and porcelain.

    Science.gov (United States)

    Lee, Sang J; Cheong, Chan Wook; Wright, Robert F; Chang, Brian M

    2014-02-01

    The purpose of this study was to investigate the shear bond strength of the porcelain repair system on alumina and zirconia core ceramics, comparing this strength with that of veneering porcelain. Veneering ceramic (n = 12), alumina core (n = 24), and zirconia core (n = 24) blocks measuring 10 × 5 × 5 mm(3) were fabricated. Veneering ceramic blocks were used as the control. Alumina and zirconia core blocks were divided into 2 groups (n = 12 each), and a slot (2 × 2 × 4 mm(3)) filled with veneering ceramics was prepared into one of the alumina and zirconia core groups (n = 12). Followed by surface treatments of micro-abrasion with 30 μm alumina particles, etching with 35% phosphoric acid and silane primer and bond, composite resin blocks (2 × 2 × 2 mm(3)) were built up and light polymerized onto the treated surfaces by 3 configurations: (a) composite blocks bonded onto veneering ceramic surface alone, (b) composite blocks bonded onto alumina core or zirconia core surfaces, (c) a 50% surface area of the composite blocks bonded to veneering ceramics and the other 50% surface area of the composite blocks to alumina core or zirconia core surfaces. The shear bond strength of the composite to each specimen was tested by a universal testing machine at a 0.5 mm/min crosshead speed. The shear bond strength was analyzed by unpaired t-tests for within the configuration groups and ANOVA for among the different configuration groups. When the mean shear bond strength was compared within groups of the same configuration, there were no statistically significant differences. Comparison of the shear bond strength among groups of different configurations revealed statistically significant differences. The mean shear bond strength of composite onto 100% veneering ceramic surface and composite onto 50% veneering 50% all-ceramic cores was statistically higher than that of composite onto 100% all-ceramic cores; however, the differences of the shear bond strength of composite bonded

  17. Porcelain veneering of titanium--clinical and technical aspects.

    Science.gov (United States)

    Haag, Per

    2011-01-01

    Gold and other alloys have long been used for the production of crowns and bridges as replacements for damaged or lost teeth. However, doubts have arisen on the suitability of using these materials for dental restorations, as gold has also shown a capacity to cause side-effects such as allergic reactions. This is especially valid for alloys, which during the last decades have been used as porcelain-fused-to metal restorations. This fact has led to an interest in using titanium instead of these alloys. Trials to use titanium for this purpose were initiated in Japan in the early 1980s. Titanium as an unalloyed metal differs in two aspects from the above named alloys: it has a phase transformation at 882 degrees C, which changes its outer and inner properties, and it has an expansion that lies between that of the porcelain types available on the market at the time. In Japan a technique for casting titanium was developed, where the after-treatment of the casting was elaborate, to re-establish the original properties of titanium. The porcelain developed for veneering had shortcomings as the rendering produced a rough surface and non satisfactory esthetics. In Sweden a new concept was introduced in 1989. Here the processing of titanium was performed by industrial methods such as milling, spark erosion and laser welding. The idea behind this was to avoid phase transformation. During the 1990s a number of porcelain products were launched and a vast number of both laboratory and clinical studies were performed and published, with varying results. In the first study of this thesis a prospective clinical trial was performed at a public dental health clinic in Sweden. Twenty-five patients were provided with 40 copings of pure titanium, which were veneered with porcelain. After 2 years 36 of these crowns were evaluated and the patients were also interviewed regarding problems such as shooting pains or difficulties in cleaning around the teeth that were crowned. This evaluation

  18. 76 FR 2920 - Porcelain-on-Steel Cooking Ware From China

    Science.gov (United States)

    2011-01-18

    ... COMMISSION Porcelain-on-Steel Cooking Ware From China AGENCY: United States International Trade Commission. ACTION: Scheduling of an expedited five-year review concerning the antidumping duty order on porcelain-on... determine whether revocation of the antidumping duty order on porcelain-on-steel cooking ware from...

  19. 76 FR 12369 - Porcelain-on-Steel Cooking Ware From China

    Science.gov (United States)

    2011-03-07

    ... COMMISSION Porcelain-on-Steel Cooking Ware From China Determination On the basis of the record \\1\\ developed... antidumping duty order on porcelain-on-steel cooking ware from China would be likely to lead to continuation... 2011), entitled Porcelain-on-Steel Cooking Ware from China: Investigation No. 731-TA- 298 (Third...

  20. The Effect of Marginal Seal of Veneering DiCor (trade name) Substrates with DiCor Plus Porcelain

    Science.gov (United States)

    1991-05-01

    gingival inflammation is associated with subgingival margins. Schmidt and Brown (1989) reviewed that restorations that violate soft tissue attachment...overcontour a restoration . Perhaps the most pragmatic point of view concerning crown contours was that by Hunter and Hunter (1990): "The ability of dental...to their respective gypsum dies. Dicor® Plus porcelain was applied to half of the specimens of two different substrate designs. All restorations were

  1. Characterization of treated porcelain surfaces via dynamic contact angle analysis.

    Science.gov (United States)

    Phoenix, R D; Shen, C

    1995-01-01

    Successful porcelain repair requires conditioning of porcelain surfaces. Conditioning is intended to facilitate wetting by repair materials and improve interfacial bonding. The objective of this investigation was to determine the effects of selected surface treatments upon the wettability of a representative feldspathic porcelain. Dynamic contact angle analysis and scanning electron microscopy were used to characterize the effects of such treatments. Standardized porcelain specimens were subjected to the following five treatment regimens: (1) control (no treatment); (2) airborne particle abrasion using 50 microns aluminum oxide; (3) etching with ammonium bifluoride gel; (4) etching with acidulated phosphate fluoride gel; and (5) etching with hydrofluoric acid gel. Following treatment, specimens were cleansed and dried. Advancing contact angles were quantified using dynamic contact angle analysis. Mean values and 95% confidence intervals were (in degrees): control, 63.8 +/- 2.7; ammonium bifluoride, 39.4 +/- 2.0; airborne particle abrading, 29.1 +/- 2.9; acidulated phosphate fluoride, 24.9 +/- 1.7; and hydrofluoric acid, 16.5 +/- 1.2. Significant differences were found between all treatment groups (P = .05). Subsequent scanning electron microscopy examination of treated surfaces indicated lesser contact angles were associated with surfaces displaying deeper and wider grooves. Apparently, the resultant increase in surface area produces increased wettability. It is inferred that an increase in surface area may correspond to enhanced resin-porcelain bonding.

  2. Valorization of rice straw waste: production of porcelain tiles

    Directory of Open Access Journals (Sweden)

    Álvaro Guzmán A

    2015-12-01

    Full Text Available Abstract The rice industry generates huge amounts of rice straw ashes (RSA. This paper presents the results of an experimental research work about the incorporation of RSA waste as a new alternative raw material for production of porcelain tiles. The RSA replaces, partially or completely, the non-plastic raw materials (quartz (feldspathic sand in this research and feldspar, that together with the clays, constitute the major constituents of formulations of porcelain tiles. A standard industrial composition (0% RSA and two more compositions in which feldspar and feldspathic sand were replaced with two percentages of RSA (12.5% RSA and 60% RSA were formulated, keeping the clay content constant. The mixtures were processed, reproducing industrial porcelain tile manufacturing conditions by the dry route and fired at peak temperatures varying from 1140-1260 ºC. The results showed that additions of 12.5% RSA in replacement of feldspar and feldspathic sand allowed producing porcelain tiles that did not display marked changes in processing behaviour, in addition to obtain a microstructure and the typical mineralogical phases of porcelain tile. Thus, an alternative use of an agricultural waste material is proposed, which can be translated into economic and environmental benefits.

  3. Effects of flux concentrations and sintering temperature on dental porcelain

    Science.gov (United States)

    Ghose, Polash; Gafur, Md. Abdul; Das, Sujan Kumar; Ranjan Chakraborty, Shyamal; Mohsin, Md.; Deb, Arun Kumar; Rakibul Qadir, Md.

    2014-02-01

    In this study, samples of dental porcelain bodies have been made by using the materials collected from selected deposits employing different mixing proportions of clay, quartz and feldspar. Dental porcelain ceramics have been successfully fabricated by using the sintering technique together with some Na2CO3 additive. The dental porcelain powder has been pressed into pellets at first and subsequently sintered at 700, 800, 900, 1000 and 1100 °C for 2 h. The physical and mechanical properties of the prepared samples have been investigated. The sintering behavior of the fired samples has been evaluated by bulk density, linear shrinkage, water absorption and apparent porosity measurements. This study includes the evaluation of the Vickers's microhardness by microhardness tester. Phase analysis and microstructural study have been performed by XRD and optical microscope respectively. Optical properties have been investigated using UV-visible spectroscopy. Influence of firing conditions on leucite formation, densification and microstructural development of the sintered samples has been investigated. It has been found that the choice of sintering temperature is one of the key factors in controlling leucite crystallization in dental porcelain ceramics. It has also been found that the flux concentration of material and the effect of temperature on preparation of dental porcelain contribute to the firing shrinkage and hardness, which has been found to increase with the increase of treatment temperature.

  4. Evaluation for the paleodose in thermoluminescence dating of porcelain

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Sources, components and calibration of paleodose were studied for proper evalua- tion of the paleodose of porcelain in thermoluminescence (TL) dating. In the TL dating of porcelain using the pre-dose technique, the β dose from the internal natural radiation in the body of porcelain is the first, the environmental dose the second, and the α dose negligible. Sample thickness of 0.2―0.5 mm was used in the paleodose calibration. For a porcelain sample of such thickness, the distribu- tion of β dose inside the sample was nonlinear when the sample (aluminium re- places porcelain in this experiment) was irradiated by a laboratory 90Sr-90Y β source. Therefore, the β dose used was only an average value. A distribution curve of β dose and the calculation of average β dose in the sample were obtained, according to the build-up and attenuation effects of β dose in the sample. The results showed that a sample thickness of 200 μm resulted in an average dose increment of about 4% compared to the surface whereas for a sample with a thickness of 400 μm, the average dose reduced by the same percentage, and that for a sample of 300 μm in thickness the average dose is equal to surface dose approximately. The average β dose in samples with various thickness can be obtained by the provided equations.

  5. Evaluation for the paleodose in thermoluminescence dating of porcelain

    Institute of Scientific and Technical Information of China (English)

    WANG WeiDa

    2008-01-01

    Sources,components and calibration of paleodose were studied for proper evaluation of the paleodose of porcelain in thermoluminescence (TL) dating. In the TL dating of porcelain using the pre-dose technique,the β dose from the internal natural radiation in the body of porcelain is the first,the environmental dose the second,and the α dose negligible. Sample thickness of 0.2-0.5 mm was used in the paleodose calibration. For a porcelain sample of such thickness,the distribution of 13 dose inside the sample was nonlinear when the sample (aluminium replaces porcelain in this experiment) was irradiated by a laboratory 90Sr-90Y βsource. Therefore,the β dose used was only an average value. A distribution curve of β dose and the calculation of average β dose in the sample were obtained,according to the build-up and attenuation effects of β dose in the sample. The results showed that a sample thickness of 200 μm resulted in an average dose increment of about 4% compared to the surface whereas for a sample with a thickness of 400 μm,the average dose reduced by the same percentage,and that for a sample of 300 μm in thickness the average dose is equal to surface dose approximately. The average β dose in samples with various thickness can be obtained by the provided equations.

  6. Adhesion to enamel, dentin, metal, and porcelain.

    Science.gov (United States)

    Kanca, J

    1994-01-01

    Adhesion has an inseparable association with cosmetic dentistry. The ability to bond well to tooth structure has allowed the placement of countless porcelain veneers and many ceramic inlays and onlays. Improved materials and techniques have offered clinicians the ability to place these restorations with skill and reliability. The past year has seen many developments and additions to the armamentarium of the cosmetic dentist. The compiled data have been placed in different sections to facilitate the learning process. Review of the following material will familiarize the clinician with the current state of the art in the adhesive aspect of cosmetic dentistry. The ability to employ adhesive techniques has revolutionized the practice of dentistry. Clinicians have at their command materials that allow the placement of thin pieces of ceramic onto tooth structure without shattering, the routine placement of composite materials into posterior teeth, the diminishing reliance on liners and bases, and lessened postoperative discomfort with the use of dentin bonding systems. It is, as previously noted, useful to separate the analyses of adhesion to each of the substrates. Advances continue to be made in each of these areas that although not necessarily facilitating treatment ease, improve the reliability of the procedure. This review attempts to highlight the significant literature of the previous year.

  7. Mechanical properties of alumina porcelain during heating

    Science.gov (United States)

    Šín, Peter; Podoba, Rudolf; ŠtubÅa, Igor; Trník, Anton

    2014-11-01

    The mechanical strength and Young's modulus of green alumina porcelain (50 wt. % of kaolin, 25 wt. % of Al2O3, and 25 wt. % of feldspar) were measured during heating up to 900 °C and 1100 °C, respectively. To this end, we used the three point-bending method and modulated force thermomechanical analysis (mf-TMA). The loss liberation - of the physically bound water (20 - 250 °C) strengthens the sample and Young's modulus increases its values significantly. The dehydroxylation that takes place in the range of 400 - 650 °C causes a slight decrease in Young's modulus. On the other hand, the mechanical strength slightly increases in this temperature range, although it has a sudden drop at 420 °C. Beyond the dehydroxylation range, above 650 °C, both Young's modulus and mechanical strength increase. Above 950 °C, a sharp increase of Young's modulus is caused by the solid-state sintering and the new structure created by the high-temperature reactions in metakaolinite.

  8. Quantitative tomographic measurements of opaque multiphase flows

    Energy Technology Data Exchange (ETDEWEB)

    GEORGE,DARIN L.; TORCZYNSKI,JOHN R.; SHOLLENBERGER,KIM ANN; O' HERN,TIMOTHY J.; CECCIO,STEVEN L.

    2000-03-01

    An electrical-impedance tomography (EIT) system has been developed for quantitative measurements of radial phase distribution profiles in two-phase and three-phase vertical column flows. The EIT system is described along with the computer algorithm used for reconstructing phase volume fraction profiles. EIT measurements were validated by comparison with a gamma-densitometry tomography (GDT) system. The EIT system was used to accurately measure average solid volume fractions up to 0.05 in solid-liquid flows, and radial gas volume fraction profiles in gas-liquid flows with gas volume fractions up to 0.15. In both flows, average phase volume fractions and radial volume fraction profiles from GDT and EIT were in good agreement. A minor modification to the formula used to relate conductivity data to phase volume fractions was found to improve agreement between the methods. GDT and EIT were then applied together to simultaneously measure the solid, liquid, and gas radial distributions within several vertical three-phase flows. For average solid volume fractions up to 0.30, the gas distribution for each gas flow rate was approximately independent of the amount of solids in the column. Measurements made with this EIT system demonstrate that EIT may be used successfully for noninvasive, quantitative measurements of dispersed multiphase flows.

  9. Chemical Expertise: Chemistry in the Royal Prussian Porcelain Manufactory.

    Science.gov (United States)

    Klein, Ursula

    2014-01-01

    Eighteenth-century chemists defined chemistry as both a "science and an art." By "chemical art" they meant not merely experimentation but also parts of certain arts and crafts. This raises the question of how to identify the "chemical parts" of the arts and crafts in eighteenth-century Europe. In this essay I tackle this question with respect to porcelain manufacture. My essay begins with a brief discussion of historiographical problems related to this question. It then analyzes practices involved in porcelain manufacture that can be reasonably identified as chemical practices or a chemical art. My analysis yields evidence for the argument that chemical experts and expertise fulfilled distinct technical functions in porcelain manufacture and, by extension, in eighteenth-century "big industry," along with its system of division of labor.

  10. Some new results of PIXE study on Chinese ancient porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, H.S. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China)]. E-mail: hscheng@fudan.edu.cn; Zhang, B. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Zhu, D. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Yang, F.J. [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Sun, X.M. [Cultural Relics and Archaeology Research Institute of Henan Province, Zheng Zhou 450000 (China); Guo, M.S. [Cultural Relics and Archaeology Research Institute of Henan Province, Zheng Zhou 450000 (China)

    2005-10-15

    This paper reports some new results obtained by PIXE on Chinese ancient porcelain. The first results concern the provenance of blue and white porcelain made during the Tang Dynasty (AD618-907), which are the earliest products found in China. The PIXE experimental results show that they were fired in Huangye Kiln, Gongyi, Henan Province. The chemical composition of the body, white glaze and of the cobalt pigment will be reported. This paper also reports the results for early Chinese blue and white porcelain made under the Yuan dynasty (AD1206-1368) in Jingdezhen, Jiangxi Province. Experimental results show that the chemical composition of the cobalt pigment used by officers and popular are similar. These materials were imported from another country. The local asbolite was used as cobalt pigment material since the early Ming Dynasty (AD1368-1644) in Jingdezhen at folk kiln, and it was used at official kiln until the 16th century.

  11. 78 FR 37571 - Certain Opaque Polymers; Institution of Investigation Pursuant to United States Code

    Science.gov (United States)

    2013-06-21

    ... COMMISSION Certain Opaque Polymers; Institution of Investigation Pursuant to United States Code AGENCY: U.S... importation, and the sale within the United States after importation of certain opaque polymers by reason of... importation, or the sale within the United States after importation of certain opaque polymers that...

  12. Failure modes and fracture origins of porcelain veneers on bilayer dental crowns.

    Science.gov (United States)

    Liu, Yihong; Liu, Guanghua; Wang, Yong; Shen, James Zhijian; Feng, Hailan

    2014-01-01

    The aims of this study were to determine the fracture origins and crack paths in the porcelain of clinically failed bilayer ceramic restorations and to reveal the correlation between the porcelain failures and material properties. Three clinically failed crowns of each material (bilayer zirconia crowns, galvano-ceramic crowns, and porcelain-fused-to-metal crowns) were collected and underwent failure analysis. The fractures found in porcelain veneers showed several characteristics including wear, Hertzian cone crack, chipping off, and delamination. The results indicated that the fracture origins and features of the porcelain in bilayer ceramic restorations might be affected by the rigidity of core materials and thickness of copings.

  13. Porcelain veneers as an alternative for esthetic treatment: clinical report.

    Science.gov (United States)

    Rotoli, B T; Lima, D A N L; Pini, N P; Aguiar, F H B; Pereira, G D S; Paulillo, L A M S

    2013-01-01

    This case report describes the restoration of the anterior dentition with porcelain laminate veneers. The advances in bonding of porcelain to tooth structure make this treatment a feasible alternative to restore teeth with alteration in shape and position in cases in which the esthetic demand is high. The rationale for various choices in this treatment protocol is detailed with reference to the pertinent literature. Thus, the clinical success of the technique depends on the correct identification of a case for which this treatment is appropriate and the successful execution of the clinical steps involved.

  14. Effect of liner and porcelain application on zirconia surface structure and composition

    Institute of Scientific and Technical Information of China (English)

    Tariq F Alghazzawi; Gregg M Janowski

    2016-01-01

    The purpose of this study was to determine if there is an effect of liner and porcelain application (layering and pressing techniques) on the surface of yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which were exposed to permutations of liner, layered porcelain, and pressed porcelain. Scanning electron microscope (SEM)/energy dispersive spectroscope (EDS) was used to identify changes in composition and microstructure after removing liner and porcelain with hydrofluoric acid. Simulated aging was also conducted to determine the effect of liner and porcelain on low-temperature degradation. The control group had a typical equiaxed grain structure, referred to as unaffected. When covered with liner or porcelain, some areas changed in structure and composition and were termed affected. The frequency of affected structure decreased when liner was covered with either layered porcelain or pressed porcelain. There were statistical differences (Po0.05) in the composition between affected and unaffected for zirconium (layered porcelain with liner:affected=60%(0.8%) (m/m), unaffected=69%(4%), layered porcelain without liner:affected=59%(3%), unaffected=65%(3%)) and oxygen (layered porcelain with liner:affected=35%(2%), unaffected=26%(4%), layered porcelain without liner:affected=35%(3%), unaffected=30%(2%)). However, there were statistical differences (Po0.05) in the composition for zirconium and oxygen of the aged layered porcelain without liner only. The liner should not be used before porcelain application, especially when using the layering technique for zirconia restorations. Furthermore, pressing should be considered the technique of choice over layering.

  15. Spontaneous CFS rhinorrhoea: role of computerized opaque cisternography; Rhinorrhee cerebro-spinale spontanee: place de la cisternographie opaque computerisee

    Energy Technology Data Exchange (ETDEWEB)

    Jouini, S.; Saidane, S.; Maamouri, M.; Shili, S.; Menif, E.; Ben Hajel, H.; El Khedim, A.; Ben Jaafar, M.; Belkahia, A. [Hopital La Rabtan Tunis (Tunisia)

    1995-12-31

    Spontaneous CSF rhinorrhoea, secondary to trauma in the great majority of cases, is very rare (3-4%). The authors report a case of spontaneous CSF rhinorrhoea secondary to an ethmoidal osteo-dural defect, diagnosed by digital cisternography and confirmed by the surgical operation. The value of digital opaque cisternography and its place in the diagnostic arsenal are discussed. (authors). 12 refs., 3 figs.

  16. Preparation of porcelain tile granulates by more environmentally sustainable processes

    Energy Technology Data Exchange (ETDEWEB)

    Gil, C.; Silvestre, D.; Piquer, J.; Garcia-Ten, J.; Quereda, E.; Vicente, M. J.

    2012-07-01

    This study examines the feasibility of manufacturing glazed porcelain tiles with a more environmentally friendly manufacturing process, by reducing water and thermal energy consumption. The process studied in this paper is dry milling in a pendulum mill, with subsequent granulation (in order to obtain a press powder with similar flow ability to that of spray dried powders). The different morphology of the new granulate with respect to the standard spray-dried granulate modifies the microstructure of the green compacts and thus, their behaviour and fired tile properties. In order to obtain porcelain tiles with the required properties (water absorption, mechanical strength,) changes have been made in the raw materials mixture and in the processing variables. Finally, porcelain tiles measuring 50x50 cm have been manufactured at industrial scale with the new granulate using a conventional firing cycle, obtaining quality levels identical to those provided by the spray-dried granulate. These results open the possibility of preparing porcelain tile body compositions through a manufacturing process alternative to the standard one, more environmentally friendly and with lower costs. (Author)

  17. Luminescence properties of porcelain ceramics relevant to restrospective radiation dosimetry

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Markey, B.G.; Poolton, N.R.J.

    1996-01-01

    . This appears to arise from the fact that OSL is potentially stimulated in a variety of component phases of the ceramic, and these phases vary from sample to sample. This article reports an initial attempt at characterising the luminescence properties of widely available porcelain wares manufactured under...

  18. Accident dosimetry using the TL from dental restoration porcelains

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, C.L.P.; Rosa, L.A.R.; Cunha, P.G. (Instituto de Radioprotecao e Dosimetria, Rio de Janeiro (Brazil))

    1985-01-01

    The thermoluminescence (TL) properties of dental restorative porcelain were investigated with the aim of using this material as a TL dosemeter to estimate high doses in radiological accidents. The irradiations were carried out with a /sup 60/Co gamma source and X rays with effective energies from 29 to 95 keV. The porcelain glow curve presents three peaks at about 393,463 and 543K. The samples have a limit of detection at about 1.29 x 10/sup -2/ C.kg/sup -1/(50 R) and their reproducibility is better than 15%. Linearity was observed from 1.29 x 10/sup -2/ to 12.9 C.kg/sup -1/(50 to 50,000 R). Over this exposure range, the dental porcelain TL response presents a maximum pre-dose sensitisation factor of 2.33. The porcelain TL sensitivity, normalised to /sup 60/Co, has a maximum of 4.8 at 29 keV due to its energy dependence.

  19. White Porcelain Jar with Double-Fish Design

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Fish were a frequently used theme forartwork in ancient times, as they arebelieved to represent ’surplus in thecoming years.’ This white porcelain jarwas a product of the Xing Kiln, HebeiProvince in the late Tang Dynasty and wasunearthed in Jingjing County. Xing Kiln is located in the areas ofNeiqiu and Lincheng and got the name

  20. Famous Chinese Porcelain and British Queen’s Wedding Anniversary

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>The 2009 China Jingdezhen International Ceramics Fair in October drew a large crowd of visitors from around the world to the capital of porcelain to admire the beautiful displays from various countries.Among them,a 12-member British delegation from the Bath & North East Somerset Council headed by Councilor Francine Haeberling had an additional special reason for their visit.

  1. Comparative Evaluation of Effects of Laser Modalities on Shear Bond Strengths of Veneering Porcelains to Laser Sintered Substructures: An In Vitro Study.

    Science.gov (United States)

    Gorler, Oguzhan; Saygin, Aysegul Goze

    2017-06-01

    Laser modalities and direct metal laser sintering (DMLS) have a potential to enhance micromechanical bonding between dental super- and infrastructures. However, the effect of different manufacturing methods on the metal-ceramic bond strength needs further evaluation. We investigated the effect of surface treatment with Er:YAG, Nd:YAG, and Ho:YAG lasers on the shear bond strength (SBS) of high-fusion dental porcelains (Vita and G-Ceram) to infrastructures prepared with DMLS in vitro settings. Study specimens (n = 128) were randomly divided into study subsets (n = 8), considering treatment types applied on the surface of infrastructures, including sandblasting and selected laser modalities; infrastructure types as direct laser sintered (DLS) and Ni-Cr based; and superstructure porcelains as Vita and G-Ceram. The SBS test was performed to assess the effectiveness of surface modifications that were also examined with a stereo microscope. Considering laser procedure types, the highest SBS values were obtained by Er:YAG laser, followed by, with a decreasing efficiency, Ho:YAG laser and sandblasting procedures, and Nd:YAG laser procedure (p laser decreases the bonding of Vita and G-Ceram in all the infrastructures compared with sandblasting. Considering porcelains, the highest SBS values were obtained by Vita (p laser procedures caused surface irregularities as revealed by the stereo microscopic examination. In current experimental settings, Er:YAG laser applied to DLS infrastructure veneered with Vita porcelain increases bonding strength more distinctly, and Nd:YAG laser applied to Ni-Cr-based infrastructure veneered with G-Ceram porcelain alters bonding strength unfavorably.

  2. THE EFFECT OF DIFFERENT SURFACE TREATMENT TECHNIQUES ON THE SURFACE ROUGHNESS OF FELDSPATHIC PORCELAIN

    Directory of Open Access Journals (Sweden)

    Fidan ALAKUŞ-SABUNCUOĞLU

    2016-10-01

    Full Text Available Purpose: This in vitro study compared the effect of five different techniques on the surface roughness of feldspathic porcelain. Materials and Methods: 100 feldspathic porcelain disk samples mounted in acrylic resin blocks were divided into five groups (n=20 according to type of surface treatment: I, hydrofluoric acid (HFA; II, Deglazed surface porcelain treated with Neodymium:yttrium- aluminum-garnet (Nd:YAG laser; III, Deglazed porcelain surface treated with Erbium:yttrium-aluminum-garnet (Er:YAG laser; IV, Glazed porcelain surface treated with Neodymium:yttrium-aluminum-garnet (Nd:YAG laser, V; Glazed porcelain surface treated with Erbium:yttrium-aluminum-garnet (Er:YAG laser. The surface roughness of porcelain was measured with a noncontact optical profilometer. For each porcelain sample, two readings were taken across the sample, before porcelain surface treatment (T1 and after porcelain surface treatment (T2. The roughness parameter analyzed was the average roughness (Ra. Statistical analysis was performed using Kolmogorov–Smirnov and Wilcoxon signed rank test. Results: Mean Ra values for each group were as follows: I, 12.64±073; II, 11.91±0.74; III, 11.76±0.59; IV, 3.82 ±0.65; V, 2.77±0.57. For all porcelain groups, the lowest Ra values were observed in Group V. The highest Ra values were observed for Group I, with a significant difference with the other groups. Kolmogorov–Smirnov showed significant differences among groups (p<0.001. Conclusion: Surface treatment of porcelain with HFA resulted in significantly higher Ra than laser groups. Both Er:YAG laser or Nd:YAG laser on the deglaze porcelain surface can be recommended as viable treatment alternatives to acid etching.

  3. Influence of framework design, contraction mismatch, and thermal history on porcelain checking in fixed partial dentures.

    Science.gov (United States)

    Anusavice, K J; Gray, A E

    1989-01-01

    The objective of this study was to characterize the relative influence of contraction mismatch, framework design, furnace type, cooling rate, and multiple firings on immediate or delayed checking in fixed partial dentures. Frameworks for 60 anterior bridges (three-unit fixed partial dentures) were cast from a low-expansion Au-Pd alloy (O) and a high-expansion Pd-Ag alloy (J). A high-expansion porcelain (B) was applied to each of three framework designs. Firing was performed at heating rates of 56 degrees C/min and 180 degrees C/min. Specimens were cooled at two rates after each of five glazing cycles. For O-B specimens which exhibited a negative thermal contraction mismatch between 600 degrees C and 25 degrees C, 60% of the bridge specimens failed when they were subjected to slow cooling preceded by either fast or slow heating. When J-B specimens (which exhibited a smaller negative contraction mismatch) were heated and cooled rapidly, no failures occurred through all of the firing cycles. However, cracks were observed in 13.3% of the J-B bridges which were slowly heated and rapidly cooled. Delayed cracks (after the fifth glaze cycle) developed over periods of up to two years only in bridges which were slowly cooled in the furnace chamber. The results of this study suggest that checking in conventional feldspathic porcelains can be promoted by slow cooling rates and an excessive number of firing cycles.

  4. Evaluation to the effect of B2O3-La2O3-SrO-Na2O-Al2O3 bonding agent on Ti6Al4V-porcelain bonding.

    Science.gov (United States)

    Zhao, C Q; Wu, S Q; Lu, Y J; Gan, Y L; Guo, S; Lin, J J; Huang, T T; Lin, J X

    2016-10-01

    Low-fusing bonding agents have been widely applied in Ti-ceramics restorations. As an important category, borate bonding agents have great potentials in increasing Ti-porcelain bonding. The purpose of this study is to evaluate the effect of borate bonding agent with addition of Na2O and Al2O3 on Ti6Al4V-porcelain bonding. The thermal properties of borate bonding agent, such as glass transition temperature (Tg) and crystallization peak temperature (Tp), were investigated to establish the sintering process. And the coefficient of thermal expansion (CTE) was to evaluate the matching effect of porcelain to Ti6Al4V. The bond strength was analyzed by the three point bending test. The microscopic morphology of the borate bonding agent surface after sintering, the interface of Ti-borate bonding agent-porcelain, and the fracture mode after porcelains fracture, were studied to assess the influence of borate bonding agent on Ti6Al4V-ceramics. With the addition of Na2O and Al2O3, the porcelain residues were observed increased indication on the Ti6Al4V surface after porcelain fracture and the bond strength was acquired the maximum (49.45MPa) in the bonding agent composition of 75.70B2O3-5.92La2O3-11.84SrO-4.67Na2O-1.87Al2O3. Those results suggest that borate bonding agent is an effective way to improve the Ti6Al4V-ceramics bond strength. And the addition of Na2O and Al2O3 strengthen this effect. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Effects of core characters and veneering technique on biaxial flexural strength in porcelain fused to metal and porcelain veneered zirconia.

    Science.gov (United States)

    Oh, Ju-Won; Song, Kwang-Yeob; Ahn, Seung-Geun; Park, Ju-Mi; Lee, Min-Ho; Seo, Jae-Min

    2015-10-01

    The purpose of this study was to assess the impact of the core materials, thickness and fabrication methods of veneering porcelain on prosthesis fracture in the porcelain fused to metal and the porcelain veneered zirconia. Forty nickel-chrome alloy cores and 40 zirconia cores were made. Half of each core group was 0.5 mm-in thickness and the other half was 1.0 mm-in thickness. Thus, there were four groups with 20 cores/group. Each group was divided into two subgroups with two different veneering methods (conventional powder/liquid layering technique and the heat-pressing technique). Tensile strength was measured using the biaxial flexural strength test based on the ISO standard 6872:2008 and Weibull analysis was conducted. Factors influencing fracture strength were analyzed through three-way ANOVA (α≤.05) and the influence of core thickness and veneering method in each core materials was assessed using two-way ANOVA (α≤.05). The biaxial flexural strength test showed that the fabrication method of veneering porcelain has the largest impact on the fracture strength followed by the core thickness and the core material. In the metal groups, both the core thickness and the fabrication method of the veneering porcelain significantly influenced on the fracture strength, while only the fabrication method affected the fracture strength in the zirconia groups. The fabrication method is more influential to the strength of a prosthesis compared to the core character determined by material and thickness of the core.

  6. The Shear Bond Strength of Porcelain Laminate to Prepared and Unprepared Anterior Teeth

    OpenAIRE

    Ali Asghar Alavi; Zeinab Behroozi; Farid Nik Eghbal

    2017-01-01

    Statement of the Problem: Porcelain laminate veneer is an esthetic restoration used as an alternative to full veneer crowns and requires minimal tooth preparation. In restoration with porcelain laminate veneers, both the longevity of the laminate and conservation of the sound tooth structure are imperative. Purpose: The present study aimed to investigate the shear bond strength of porcelain laminates to prepared- and unprepared- anterior teeth in order to compare their longevity and succes...

  7. Porcelain in the Ming Dynasty:Cultural and Artistic Exchanges Between Hans and Tibetans

    Institute of Scientific and Technical Information of China (English)

    WuMingdi

    2004-01-01

    As an example of Chinese arts and crafts, porcelain is an important element of Chinese culture. In ancient times, when transport and communications were extremely backward, the continuous flow of porcelain items between Han Chinese and Tibetans played an essential role in their material and cultural life. Put specifically, the close relationship between porcelain and Han-Tibetan cultural and artistic exchanges can be observed as follows:

  8. Effectiveness of Combination of Dentin and Enamel Layers on the Masking Ability of Porcelain.

    Science.gov (United States)

    Boscato, Noéli; Hauschild, Fernando Gabriel; Kaizer, Marina da Rosa; De Moraes, Rafael Ratto

    2015-01-01

    This study evaluated the masking ability of different porcelain thicknesses and combination of enamel and/or dentin porcelain layers over simulated background dental substrates with higher (A2) and lower (C4) color values. Combination of the enamel (E) and dentin (D) monolayer porcelain disks with different thicknesses (0.5 mm, 0.8 mm, and 1 mm) resulted in the following bilayer groups (n=10): D1E1, D1E0.8; D1E0.5; D0.8E0.8; D0.8E0.5, and D0.5E0.5. CIELAB color coordinates were measured with a spectrophotometer. The translucency parameter of mono and bilayer specimens and the masking ability estimated by color variation (ΔE*ab) of bilayer specimens over simulated dental substrates were evaluated. Linear regression analysis was used to investigate the relationships translucency parameter × ΔE*, translucency parameter × porcelain thickness, and ΔE* × porcelain thickness. Data were analyzed statistically (α= 0.05). Thinner porcelain disks were associated with higher translucency. Porcelain monolayers were considerably more translucent than bilayers (enamel + dentin). Dentin porcelain was less translucent than enamel porcelain with same thickness. ΔE* was always lower when measured over A2 background. Higher ΔE* was observed for the C4 background, indicating poorer masking ability. Increased ΔE* was significantly associated with increased translucency for both backgrounds. Decreased translucency and ΔE* were associated with increased total porcelain thickness or increased dentin thickness for both backgrounds. In conclusion, increased porcelain thickness (particularly increased dentin layer) and increased porcelain opacity resulted in better masking ability of the dental backgrounds.

  9. Effect of different sources of alumina on the microstructure and mechanical properties of the triaxial porcelain

    OpenAIRE

    Gralik,G.; Chinelattot,A. L.; A. S. A. Chinelatto

    2014-01-01

    Porcelains composed of kaolin-quartz-feldspar are called triaxial porcelains. The use of alumina as a substitute for quartz in porcelains has been developed for some time. The results show a significant improvement in their mechanical properties, but alumina has a high cost. The possibility of using alternative materials as a source of alumina with lower cost was investigated. In this work, alternative raw materials were used as a source of alumina: refractory bauxite, primary aluminum hydrox...

  10. Non-Gold Base Dental Casting Alloys. Volume 2. Porcelain-Fused-to-Metal Alloys.

    Science.gov (United States)

    1986-08-01

    kaolin , and/or alumina. a. Quartz Quartz has a high fusion temperature , and acts as the frimeworK around which the other ingredients can flow.7 Quartz...until it has cooled to room temperature . The metal and the - porcelain retain heat differently , and thus will cool at different rates. Rushing the case at...dental porcelain to a recommended temperature for a specific period of time. SINTERING - Another term to describe the "firing" of dental porcelain

  11. A Review of Porcelain Gallbladder Mimicking a Gallbladder Stone on Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Hyun Sun [Dept. of Preventive Medicine, Cheju National University College of Medicine, Cheju (Korea, Republic of); Jung, Hong Rayang; Lim, Chung Hwan [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of)

    2008-12-15

    Porcelain gallbladder is a rare disorder by deposition of calcium in the wall of gallbladder. The chronic cholecystitis is reported to produce mural calcification and obstruction to the cystic duct by stone. Since porcelain gallbladder is commonly associated with gallbladder cancer, cholecystectomy is performed to prevent it. We report here a case of a patient with porcelain gallbladder. This case showed the typical ultrasonographic, computer tomographic and radiographic findings of the disease.

  12. Analyzing the effect of ion exchange on flexural strength of cermaco II and colorlogic veneer porcelains

    Directory of Open Access Journals (Sweden)

    N. Rashidan

    1998-04-01

    Full Text Available   The major foible of dental ceramics is their brittle nature. Therefore, the producers of these materials have focused on the “strength” issue. A method of increasing strength is ion exchange on porcelain surface which leads to formation of a compressive crust that opposing forces should overcome before developing a crack. In current study, ion exchange in two types of porcelain, Ceramco II which is used in PFM restorations and Colorloic veneer which is used for laminates, veneers, inlays and onlays, are evaluated. Additionally, laminate porcelains, etching effect on strength of porcelain and interaction of acid etching and ion exchange have been studied.

  13. Mechanically strengthened new Hagi porcelain developed by controlling the chemical environment of iron

    Science.gov (United States)

    Kubuki, Shiro; Iwanuma, Jun; Akiyama, Kazuhiko; Mikuni, Akira; Nishida, Tetsuaki

    2012-05-01

    In order to enhance the mechanical strength of Hagi Porcelain (Hagiyaki), one of the oldest and famous potteries in Japan, new preparation condition was examined. Tempered Hagi porcelain, denominated as ` Hagi Porcelain B', was prepared with the Porcelain clay originating from Daido district, Yamaguchi Prefecture, Japan. Structural change of ` Hagi Porcelain B' was investigated by means of 57Fe-Mössbauer spectroscopy, X-ray diffractometry (XRD) and three-point bending test. Mechanical strength of the ` original Hagi Porcelain B' was estimated to be 43.1 MPa by means of the three-point bending test, while much larger value of 104.5 MPa could be achieved when tempered by a chemical modification. Mössbauer spectrum of the ` original Hagi porcelain B' was composed of a paramagnetic doublet and a magnetic sextet due to Fe(III) of γ-Fe2O3(maghemite), while only one paramagnetic doublet due to to octahedral Fe(II)O6 was observed for the ` tempered Hagi Porcelain B' with isomer shift and quadrupole splitting values of 1.13 and 2.15 mm s-1, respectively. It is considered that the absence of magnetic phase causes an increase of the mechanical strength because the maghemite phase has a defect spinel structure. These results indicate that mechanical strength of the ` Hagi porcelain B' could be enhanced by controlling the sintering condition.

  14. Investigation on the Tribological Behavior and Wear Mechanism of Five Different Veneering Porcelains.

    Directory of Open Access Journals (Sweden)

    Jie Min

    Full Text Available The primary aim of this research was to investigate the wear behavior and wear mechanism of five different veneering porcelains.Five kinds of veneering porcelains were selected in this research. The surface microhardness of all the samples was measured with a microhardness tester. Wear tests were performed on a ball-on-flat PLINT fretting wear machine, with lubrication of artificial saliva at 37°C. The friction coefficients were recorded by the testing system. The microstructure features, wear volume, and damage morphologies were recorded and analyzed with a confocal laser scanning microscope and a scanning electron microscope. The wear mechanism was then elucidated.The friction coefficients of the five veneering porcelains differ significantly. No significant correlation between hardness and wear volume was found for these veneering porcelains. Under lubrication of artificial saliva, the porcelain with higher leucite crystal content exhibited greater wear resistance. Additionally, leucite crystal size and distribution in glass matrix influenced wear behavior. The wear mechanisms for these porcelains were similar: abrasive wear dominates the early stage, whereas delamination was the main damage mode at the later stage. Furthermore, delamination was more prominent for porcelains with larger crystal sizes.Wear compatibility between porcelain and natural teeth is important for dental restorative materials. Investigation on crystal content, size, and distribution in glass matrix can provide insight for the selection of dental porcelains in clinical settings.

  15. [Strength and transparency of dental porcelain consisting of high refractive germanate-glass and alumina crystal].

    Science.gov (United States)

    Kon, M

    1990-07-01

    A translucent aluminous porcelain was developed for dentistry. The effects of refractive indexes and sintering behaviors on transparency and strength of the aluminous porcelains consisting of high refractive germanate-glass (Na2O-TiO2-GeO2) and alumina crystal powders were examined. The various germanate-glass specimens with a high refractive index were made by fusion at about 1,300 degrees C. The refractive indexes of fused Na2O-TiO2-GeO2 glass specimens were 1.64-1.76, heightened with an increasing TiO2 content. The sintered aluminous porcelains were made from the mixed compacts consisting of 80 wt% germanate-glass and 20 wt% alumina at the densification temperature of 580-820 degrees C. Sintered aluminous porcelains prepared with high refractive germante-glass had a high transparency compared with the other aluminous porcelains, with almost the same transparency as a commercial feldspathic porcelain (body). Aluminous porcelains had lower transparency with different refractive index due to generation of crystals following the crystallization of glass matrix than that without crystallizing property. Bending strength value was 120 MPa, which is similar to that for the glass-alumina ceramics with the same content of alumina volume as germanate-glass aluminous porcelains. Non-crystallized aluminous porcelain had a higher strength compared with the crystallized one.

  16. Field experience and electrical characteristics of punctured porcelain suspension insulators

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, D.H. [Institut de Recherche d`Hydro-Quebec, Varennes, PQ (Canada)

    1997-12-31

    The condition and electrical characteristics of porcelain insulators in service at Hydro-Quebec were investigated through a series of live-line tests. More than 2,000 insulator strings on the distribution system were checked under energized field conditions using different detection devices. About 200 faulty insulators and representative sound insulators were removed and analyzed in the laboratory in an effort to assess the efficiency of the different devices used to detect the faulty insulators. The detection of faulty insulator units is necessary to maintain system reliability. Insulator deterioration was found to be caused by inherent porosity and manufacturing defects in the porcelain shell and by expansion forces produced by insulator pin-hole cement. 2 refs., 3 figs.

  17. A simplified approach to the complete porcelain margin.

    Science.gov (United States)

    Vryonis, P

    1979-11-01

    The technique described produces a metal-ceramic crown exhibiting excellent esthetic qualities and marginal accuracy superior to that achieved on the cast metal margin. A platinum foil apron or refractory dies are not necessary. A precise shoulder preparation, preferably with two master dies, is required. A chamfer with a bevel, a shoulder with a bevel, or chamfer preparations are not suited to this technique. Quantitative evaluation using a measuring microscope showed that a marginal gap on a crown fabricated on an International Bureau of Standards crown die measured 6 microns at the porcelain shoulder and from 17 to 34 microns on a gold margin of the same crown. On a prepared-tooth, rubber-base compression densite die, the marginal gap on the porcelain shoulder was 10 microns.

  18. Changing the guard: Polymer replaces porcelain for surge arresters

    Energy Technology Data Exchange (ETDEWEB)

    Skytt, T.; Gleimar, H. E. G.

    2002-07-01

    Surge arresters are safety devices which quickly and effectively limit the over voltages that can arise in transmission networks following lightning, switching and other transient events. The earliest forms of overvoltage protection, a simple air gap between electrodes, have long since been replaced by a new generation of gapless arresters with series-connected, non-linear zinc oxide varistors contained in a porcelain housing. Now these porcelain type surge arresters are being replaced by a new type, called PEXLIM (Polymeric EXcellent LIMiter), which uses the same block of zinc oxide as the porcelain type, but its housing is made of silicon rubber, a polymer. The new lightweight insulation material shows a number of properties superior to the porcelain, such as enhanced product safety and ease of handling. It is also more durable, resilient, yet solid and compact, water-repellent, lightweight, resistant to aging or light or ultra-violet radiation, as well as fire, has good electrical properties, and is environmentally friendly since it does not contain any substances harmful to the environment. These properties make this new type of surge arrester highly suitable for use in earthquake-prone areas; it can also replace more expensive and maintenance-intensive equipment. Having successfully broken into the lower voltage systems, these new type of surge arresters are now rapidly gaining ground at the higher voltage levels. ABB, the developer of PEXLIM, has already supplied these arresters to North America for use in an 800-kV grid. As further proof of its growing popularity, last year PEXLIM made up over half of the surge arrester production for applications up to and including 245 kV. 1 tab., 6 figs.

  19. Characterization of Mechanical Properties of Porcelain Tile Using Ultrasonics

    OpenAIRE

    KURAMA, Semra; Eren, Elif

    2012-01-01

    Ultrasound affords a very useful and versatile non-destructive method, using a large application area, for evaluating the microstructure and mechanical properties of materials. In this study, porcelain tiles were sintered at different temperatures to change their porosity. Following this, the time of flight of both longitudinal and shear waves was measured through the tile. The time of flight of ultrasonic waves was measured using a contact ultrasonic transducer operating on a pulse-echo mode...

  20. Radiated Electromagnetic Field Signature of Cracked and Polluted Porcelain Insulators%Radiated Electromagnetic Field Signature of Cracked and Polluted Porcelain Insulators

    Institute of Scientific and Technical Information of China (English)

    Ehsan Azordegan; David R Swatek; Behzad Kordi

    2011-01-01

    Porcelain cap and pin insulators are by far the most popular suspension insulators in high voltage (HV) dis- tribution networks all around the world. Inspection and condition monitoring of HV insulators is also very important to the utility companies because of the critical and vital role that they play in distribution systems. In terms of safety, practicality and ease of use, remote detection methods are more popular among the line technicians. A new remote condition assessment method based on electromagnetic radiations from porcelain insulators is presented in this gaper. In a lab environment, a string of two porcelain insulators is energized by a 45 kV transformer. Electromagnetic radia- tions due tO the partial"discharge activities inside the porcelain insulator are captured by passive sensors and antennas. Two cases of defective insulators on a two insulator string are studied here. The first case focuses on the effect of con- taminated porcelain shells on radiation signature of partial discharges. A polluted porcelain shell with ESDD level of 0.03 mg/cmz was first tested. The second case studies the effect of cracks of an intentionally-cracked porcelain shell. The cracked insulator is also tested on a two insulator string. To compare the partial discharge radiation signature of different faulty insulators, phase resolved graphs were developed. The electromagnetic radiated signature of a polluted insulator and a cracked insulator was'calculated and compared using phase resolved graphs.

  1. Petrogenesis of opaque assemblages in the Ningqiang carbonaceous chondrite

    Institute of Scientific and Technical Information of China (English)

    HSU; WeiBiao

    2007-01-01

    Numerous round to oblate opaque assemblages (OAs) are found in chondrules and matrix of the Ningqiang carbonaceous chondrite. They are mainly composed of Ni-rich metal,magnetite,Fe,Ni-sulfides,with minor amounts of phosphate,phosphoran-olivine,pyroxene and trace amounts of nano-sized platinum-group metal alloys. The mineralogy of Ningqiang OAs is very similar to that of OAs previously reported in Ca,Al-rich inclusions of CV chondrites. Being a rare mineral phase in nature,phosphoran-olivine is thought to form by nonequilibrium reactions between P-bearing molten metal and olivine crystals during rapid cooling. Its occurrence in Ningqiang OAs indicates that the precursor of OAs was locally produced during chondrule formation,rather than directly condensed from the solar nebula as previously thought. The petrographic and mineralogical characteristics of Ningqiang OAs reveal that OAs formed by low temperature alterations of pre-existing homogeneous alloys within chondrules on a planetary body.

  2. Watermarking Java Programs using Dummy Methods with Dynamically Opaque Predicates

    CERN Document Server

    Akbar, Zaenal

    2010-01-01

    Software piracy, the illegal using, copying, and resale of applications is a major concern for anyone develops software. Software developers also worry about their applications being reverse engineered by extracting data structures and algorithms from an application and incorporated into competitor's code. A defense against software piracy is watermarking, a process that embeds a secret message in a cover software. Watermarking is a method that does not aim to stop piracy copying, but to prove ownership of the software and possibly even the data structures and algorithms used in the software. The language Java was designed to be compiled into a platform independent bytecode format. Much of the information contained in the source code remains in the bytecode, which means that decompilation is easier than with traditional native codes. In this thesis, we present a technique for watermarking Java programs by using a never-executed dummy method (Monden et.al., 2000) combined with opaque predicates (Collberg et.al...

  3. Petrogenesis of opaque assemblages in the Ningqiang carbonaceous chondrite

    Institute of Scientific and Technical Information of China (English)

    WANG Ying; HUA Xin; HSU WeiBiao

    2007-01-01

    Numerous round to oblate opaque assemblages (OAs) are found in chondrules and matrix of the Ningqiang carbonaceous chondrite. They are mainly composed of Ni-rich metal, magnetite, Fe,Ni-sulfides, with minor amounts of phosphate, phosphoran-olivine, pyroxene and trace amounts of nano-sized platinum-group metal alloys. The mineralogy of Ningqiang OAs is very similar to that of OAs previously reported in Ca, Al-rich inclusions of CV chondrites. Being a rare mineral phase in nature,phosphoran-olivine is thought to form by nonequilibrium reactions between P-bearing molten metal and olivine crystals during rapid cooling. Its occurrence in Ningqiang OAs indicates that the precursor of OAs was locally produced during chondrule formation, rather than directly condensed from the solar nebula as previously thought. The petrographic and mineralogical characteristics of Ningqiang OAs reveal that OAs formed by low temperature alterations of pre-existing homogeneous alloys within chondrules on a planetary body.

  4. The opaque nascent starburst in NGC 1377: Spitzer SINGS observations

    CERN Document Server

    Roussel, H; Bendo, G J; Dale, D A; Draine, B T; Engelbracht, C W; Gordon, K D; Helou, G; Hollenbach, D J; Kennicutt, R C; Meyer, M J; Moustakas, J; Murphy, E J; Regan, M W; Rieke, G H; Sheth, K; Smith, J D; Spoon, H W; Walter, F

    2006-01-01

    We analyze extensive data on NGC1377 from the Spitzer Infrared Nearby Galaxies Survey (SINGS). Within the category of nascent starbursts, that we previously selected by their infrared to radio continuum ratios in large excess of the average and their hot dust, NGC1377 has the largest infrared excess yet measured. Optical imaging reveals a morphological distortion suggestive of a recent accretion event. Infrared spectroscopy reveals a compact and opaque source dominated by a hot, self-absorbed continuum (tau ~ 20 in the 10 micron silicate band). We provide physical evidence against non-stellar activity being the heating source. HII regions are detected through the single [NeII] line, probing 85% of ionizing photons are suppressed by dust. The only other detected emission features are molecular hydrogen lines, arguably excited mainly by shocks, besides photodissociation regions, and weak aromatic bands. The new observations support our interpretation in terms of an extremely young starburst (<1 Myr). More ge...

  5. Mechanical and chemical analyses across dental porcelain fused to CP titanium or Ti6Al4V

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Júlio C.M., E-mail: jsouza@dem.uminho.pt [Centre of Microelectromechanical Systems (CMEMS), Dept. of Mechanical Engineering, Universidade do Minho, P-4800-058 Guimarães (Portugal); PPGO, CCS, Dept. of Dentistry (ODT), Universidade Federal de Santa Catarina (UFSC), 88040-900 Florianópolis, SC (Brazil); Henriques, Bruno [Centre of Microelectromechanical Systems (CMEMS), Dept. of Mechanical Engineering, Universidade do Minho, P-4800-058 Guimarães (Portugal); Dept. Materials Engineering, Universidade Federal do Rio Grande do Norte (UFRN), 59072-970 Natal, RN (Brazil); Ariza, Edith [Centre of Microelectromechanical Systems (CMEMS), Dept. of Mechanical Engineering, Universidade do Minho, P-4800-058 Guimarães (Portugal); Martinelli, Antonio E.; Nascimento, Rubens M. [Dept. Materials Engineering, Universidade Federal do Rio Grande do Norte (UFRN), 59072-970 Natal, RN (Brazil); Silva, Filipe S. [Centre of Microelectromechanical Systems (CMEMS), Dept. of Mechanical Engineering, Universidade do Minho, P-4800-058 Guimarães (Portugal); Rocha, Luís A. [Centre of Microelectromechanical Systems (CMEMS), Dept. of Mechanical Engineering, Universidade do Minho, P-4800-058 Guimarães (Portugal); Dept. of Physics, Universidade Estadual Paulista “Júlio de Mesquita Filho” (UNESP), 17033-360, Bauru SP (Brazil); Celis, Jean-Pierre [Dept. MTM, Katholieke Universiteit Leuven, B-3001 Leuven (Belgium)

    2014-04-01

    The aim of this study was to evaluate the evolution of mechanical properties and chemical variation across veneering dental porcelain fused to different titanium-based substrates. Test samples were synthesized by fusing dental feldspar-based porcelain onto commercially pure titanium grade II or Ti6Al4V alloy. Samples were cross-sectioned at angles of 10 and 90° to the interface plane. Afterwards, nanoindentation tests and Scanning Electron Microscopy (SEM) imaging coupled to an Energy Dispersive Spectroscopy (EDS) system were carried out across interfaces extending from the metal towards the porcelain area. Elemental diffusion profiles across the porcelain-to-metal interfaces were also obtained by EDS analysis. The mismatch in mechanical properties found in porcelain-to-Ti6Al4V interfaces was lower than that of porcelain-to-CP titanium. Cracking was noticed at low-thickness veneering dental porcelain regions after the nanoindentation tests of samples cross-sectioned at low angles to the interface plane. A wide reaction zone between titanium and porcelain as well as higher incidence of defects was noticed at the porcelain-to-CP titanium interfaces. This study confirmed Ti6Al4V as an improved alternative to CP-titanium as it showed to establish a better interface with the veneering dental porcelain considering the slight chemical interaction and the lower mechanical properties mismatch. The elastic modulus of porcelain-to-Ti6Al4V samples showed to be less sensitive to porcelain thickness variations. - Highlights: • This study reveals mechanical and chemical behaviors across porcelain/titanium interfaces. • Cracks were noticed after nanoindentation on thin porcelain layers. • Ti6Al4V/porcelain showed a better mechanical behavior than that at CP-Ti/porcelain.

  6. The bond strength of porcelain to Ni-Cr alloy--the influence of tin or chromium plating.

    Science.gov (United States)

    Inoue, K; Murakami, T; Terada, Y

    1992-01-01

    Nickel-chromium alloys were plated with tin and chromium to evaluate the effect on porcelain shear bond strength. Six plating methods were used. Additionally, the microstructure of the bond between the plated alloy and porcelain were studied using SEM and EPMA. Tin plating increased the bond strength of porcelain to a nickel-chromium alloy while chromium plating did not.

  7. 75 FR 81967 - Porcelain-on-Steel Cooking Ware From Taiwan: Final Results of Sunset Review and Revocation of...

    Science.gov (United States)

    2010-12-29

    ...] Porcelain-on-Steel Cooking Ware From Taiwan: Final Results of Sunset Review and Revocation of Antidumping... of the antidumping duty order on porcelain-on-steel cooking ware (POS cooking ware) from Taiwan... antidumping duty order is porcelain-on-steel cooking ware from Taiwan that does not have self-...

  8. Mechanical and chemical analyses across dental porcelain fused to CP titanium or Ti6Al4V.

    Science.gov (United States)

    Souza, Júlio C M; Henriques, Bruno; Ariza, Edith; Martinelli, Antonio E; Nascimento, Rubens M; Silva, Filipe S; Rocha, Luís A; Celis, Jean-Pierre

    2014-04-01

    The aim of this study was to evaluate the evolution of mechanical properties and chemical variation across veneering dental porcelain fused to different titanium-based substrates. Test samples were synthesized by fusing dental feldspar-based porcelain onto commercially pure titanium grade II or Ti6Al4V alloy. Samples were cross-sectioned at angles of 10 and 90° to the interface plane. Afterwards, nanoindentation tests and Scanning Electron Microscopy (SEM) imaging coupled to an Energy Dispersive Spectroscopy (EDS) system were carried out across interfaces extending from the metal towards the porcelain area. Elemental diffusion profiles across the porcelain-to-metal interfaces were also obtained by EDS analysis. The mismatch in mechanical properties found in porcelain-to-Ti6Al4V interfaces was lower than that of porcelain-to-CP titanium. Cracking was noticed at low-thickness veneering dental porcelain regions after the nanoindentation tests of samples cross-sectioned at low angles to the interface plane. A wide reaction zone between titanium and porcelain as well as higher incidence of defects was noticed at the porcelain-to-CP titanium interfaces. This study confirmed Ti6Al4V as an improved alternative to CP-titanium as it showed to establish a better interface with the veneering dental porcelain considering the slight chemical interaction and the lower mechanical properties mismatch. The elastic modulus of porcelain-to-Ti6Al4V samples showed to be less sensitive to porcelain thickness variations.

  9. CO2 Laser Glazing Treatment of a Veneering Porcelain: Effects on Porosity, Translucency, and Mechanical Properties.

    Science.gov (United States)

    Sgura, R; dos Reis, M C; Salvadori, M C; Hernandes, A C; Cesar, P F; Medeiros, I S

    2015-01-01

    This work tested CO2 laser as a glazing agent and investigated the effects of irradiation on the porosity, translucency, and mechanical properties of veneering porcelain. Sixty discs (diameter 3.5 × 2.0 mm) of veneering porcelain for Y-TZP frameworks (VM9, VITA Zahnfabrik) were sintered and had one of their faces mirror polished. The specimens were divided into six groups (n=10/group) according to surface treatment, as follows: no treatment-control; auto-glaze in furnace following manufacturer's instructions (G); and CO2 laser (45 or 50 W/cm(2)) applied for four or five minutes (L45/4, L45/5, L50/4, L50/5). Optical microscopy (Shimadzu, 100×) was conducted and the images were analyzed with Image J software for the determination of the following porosity parameters: area fraction, average size, and Feret diameter. The translucency parameter studied was masking ability, determined by color difference (ΔE) over black and white backgrounds (CM3370d, Konica Minolta). Microhardness and fracture toughness (indentation fracture) were measured with a Vickers indenter (HMV, Shimadzu). Contact atomic force microscopy (AFM) (50 × 50 μm(2), Nanoscope IIIA, Veeco) was performed at the center of one sample from each group, except in the case of L45/5. With regard to porosity and translucency parameters, auto-glazed and laser-irradiated specimens presented statistical similarity. The area fraction of the surface pores ranged between 2.4% and 5.4% for irradiated specimens. Group L50/5 presented higher microhardness when compared to the G group. The higher (1.1) and lower (0.8) values for fracture toughness (MPa.m(1/2)) were found in laser-irradiated groups (L50/4 and L45/4, respectively). AFM performed after laser treatment revealed changes in porcelain surface profile at a submicrometric scale, with the presence of elongated peaks and deep valleys.

  10. Japanese Porcelain Artwork “Blue Planet of Human Life” Donated to CPAFFC

    Institute of Scientific and Technical Information of China (English)

    Pan; Lin

    2013-01-01

    <正>On March 22, a donation ceremony of the Japanese porcelain artwork the "Blue Planet of Human Life" was held in the Peace Palace of the CPAFFC. This huge spherical porcelain art-work, with a diameter of 1.05 meters, a total height of 2.1 meters and a weight of 300 kilograms, was designed and

  11. A practical method for chairside repair of debonded porcelain denture teeth

    NARCIS (Netherlands)

    Ozcan, M.

    2006-01-01

    The bonding of porcelain denture teeth to polymethylmethacrylate remains a clinical problem. In this article an alternative chairside method, based on silica coating and silanization for adhesion of denture tooth porcelain to polymethylmethacrylate is described. Copyright (copyright) 2006 by The Ame

  12. [Preliminary study of bonding strength between diatomite-based dental ceramic and veneering porcelains].

    Science.gov (United States)

    Lu, Xiao-li; Gao, Mei-qin; Cheng, Yu-ye; Zhang, Fei-min

    2015-04-01

    In order to choose the best veneering porcelain for diatomite-based dental ceramic substrate, the bonding strength between diatomite-based dental ceramics and veneering porcelains was measured, and the microstructure and elements distribution of interface were analyzed. The coefficient of thermal expansion (CTE) of diatomite-based dental ceramics was detected by dilatometry. Three veneering porcelain materials were selected with the best CTE matching including alumina veneering porcelain (group A), titanium porcelain veneering porcelain (group B), and E-max veneering porcelain (group C). Shear bonding strength was detected. SEM and EDS were used to observe the interface microstructure and element distribution. Statistical analysis was performed using SPSS 17.0 software package. The CTE of diatomite-based dental ceramics at 25-500 degrees centigrade was 8.85×10-6K-1. The diatomite-based substrate ceramics combined best with group C. Shear bonding strength between group A and C and group B and C both showed significant differences(Pdiatomite-based substrate ceramics combines better with E-max porcelain veneer.

  13. Different surface preparation techniques of porcelain repaired with composite resin and fracture resistance

    Directory of Open Access Journals (Sweden)

    Mohd Helmy Khalid Abd Wahab

    2011-01-01

    Full Text Available Background : Porcelain from prosthesis such as crown or bridge can be fractured if exposed to trauma; and, can be repaired at chairside using composite resin. Aim : To investigate the fracture resistance of few techniques of surface preparation in repairing fractured porcelain using composite resin. Materials and Methods : Eighty samples of porcelain blocks were divided into 4 groups for different surface preparations, such as, Cimara repairing kit; porcelain etch kit containing hydrofluoric acid; Panavia F resin cement; and, sandblasting using aluminium oxide, before composite resin (Filtek Z250, 3M ESPE was bonded to the prepared porcelain blocks. Twenty others samples in the control group comprised of pure porcelain blocks. The fracture resistance of each sample was tested using Instron machine (UK. Results : With the exception of the group repaired using hydrofluoric acid (3.04±1.04 Mpa, all the other groups showed significant difference in the fracture resistance values when compared to the control group (3.05 ± 1.42 MPa at P<0.05. Conclusions : Etching of the porcelain blocks with hydrofluoric acid holds promise in the repair of fractured porcelain with composite resin at chairside.

  14. Opaque closed chambers underestimate methane fluxes of Phragmites australis (Cav.) Trin. ex Steud.

    Science.gov (United States)

    Günther, Anke; Jurasinski, Gerald; Huth, Vytas; Glatzel, Stephan

    2014-04-01

    Closed chamber measurements for methane emission estimation are often carried out with opaque chambers to avoid heating of the headspace. However, mainly in wetlands, some plants possess an internal convective gas transport which quickly responds to changes in irradiation. These plants have also been found to often channel a large part of the released methane in temperate fens. We compare methane fluxes derived from transparent versus opaque chambers on Carex-, Phragmites-, and Typha-dominated stands of a temperate fen. Transparent chamber fluxes almost doubled opaque chamber fluxes in the convective transporting Phragmites stand. In Typha, a trend of higher fluxes determined with the transparent chambers was detectable, whereas in Carex, transparent and opaque chamber fluxes did not differ significantly. Thus, opaque chambers bias the outcome of methane measurements, depending on dominant vegetation. We recommend the use of transparent chambers when determining emissions of convective plants or extrapolating fluxes to larger scales.

  15. TGA-DTA and chemical composition study of raw material of Bikaner region for electrical porcelain

    Science.gov (United States)

    Tak, S. K.; Shekhawat, M. S.; Mangal, R.

    2013-06-01

    Porcelains are vitrified and a fine grained ceramic product, used either glazed or unglazed and is often manufactured from a tri-axial body mix of clays, quartz and alkaline feldspar. Physical properties associated with porcelain include those of permeability, high strength, hardness, glassiness, durability, whiteness, translucence, resonance, brittleness, high resistance to the passage of electricity, high resistance to thermal shock and high elasticity[1,2]. Porcelain insulators are made from three raw materials; clay; feldspar and quartz. For porcelain manufacture the clay is categorized in two groups; ball clay and kaolin, each of which plays an important role, either in the preparation of the product or in the properties of the finished products. The following research highlights the importance that suits these materials for their contributions to the final properties of the product. Keeping this view a TGA-DTA and chemical composition of these raw materials were observed and these materials are found suitable for production of Electrical Porcelain.

  16. Porcelain-coated antenna for radio-frequency driven plasma source

    Science.gov (United States)

    Leung, Ka-Ngo; Wells, Russell P.; Craven, Glen E.

    1996-01-01

    A new porcelain-enamel coated antenna creates a clean plasma for volume or surface-conversion ion sources. The porcelain-enamel coating is hard, electrically insulating, long lasting, non fragile, and resistant to puncture by high energy ions in the plasma. Plasma and ion production using the porcelain enamel coated antenna is uncontaminated with filament or extraneous metal ion because the porcelain does not evaporate and is not sputtered into the plasma during operation. Ion beams produced using the new porcelain-enamel coated antenna are useful in ion implantation, high energy accelerators, negative, positive, or neutral beam applications, fusion, and treatment of chemical or radioactive waste for disposal. For ion implantation, the appropriate species ion beam generated with the inventive antenna will penetrate large or small, irregularly shaped conducting objects with a narrow implantation profile.

  17. Identification and Characterization of Wor4, a New Transcriptional Regulator of White-Opaque Switching

    Directory of Open Access Journals (Sweden)

    Matthew B. Lohse

    2016-03-01

    Full Text Available The human fungal pathogen Candida albicans can switch between two cell types, “white” and “opaque,” each of which is heritable through many cell divisions. Switching between these two cell types is regulated by six transcriptional regulators that form a highly interconnected circuit with multiple feedback loops. Here, we identify a seventh regulator of white-opaque switching, which we have named Wor4. We show that ectopic expression of Wor4 is sufficient to drive switching from the white to the opaque cell type, and that deletion of Wor4 blocks switching from the white to the opaque cell type. A combination of ectopic expression and deletion experiments indicates that Wor4 is positioned upstream of Wor1, and that it is formally an activator of the opaque cell type. The combination of ectopic expression and deletion phenotypes for Wor4 is unique; none of the other six white-opaque regulators show this pattern. We determined the pattern of Wor4 binding across the genome by ChIP-seq and found it is highly correlated with that of Wor1 and Wor2, indicating that Wor4 is tightly integrated into the existing white-opaque regulatory circuit. We previously proposed that white-to-opaque switching relies on the activation of a complex circuit of feedback loops that remains excited through many cell divisions. The identification of a new, central regulator of white-opaque switching supports this idea by indicating that the white-opaque switching mechanism is considerably more complex than those controlling conventional, nonheritable patterns of gene expression.

  18. Four chemical methods of porcelain conditioning and their influence over bond strength and surface integrity

    Science.gov (United States)

    Stella, João Paulo Fragomeni; Oliveira, Andrea Becker; Nojima, Lincoln Issamu; Marquezan, Mariana

    2015-01-01

    OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding. METHODS: Four experimental groups (n = 13) were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid etching followed by silane application; G2 = 37% liquid phosphoric acid etching, no rinsing, followed by silane application; G3 = 10% hydrofluoric acid etching alone; and G4 = 10% hydrofluoric acid etching followed by silane application. After surface conditioning, metal brackets were bonded to porcelain by means of the Transbond XP system (3M Unitek). Samples were submitted to shear bond strength tests in a universal testing machine and the surfaces were later assessed with a microscope under 8 X magnification. ANOVA/Tukey tests were performed to establish the difference between groups (α= 5%). RESULTS: The highest shear bond strength values were found in groups G3 and G4 (22.01 ± 2.15 MPa and 22.83 ± 3.32 Mpa, respectively), followed by G1 (16.42 ± 3.61 MPa) and G2 (9.29 ± 1.95 MPa). As regards surface evaluation after bracket debonding, the use of liquid phosphoric acid followed by silane application (G2) produced the least damage to porcelain. When hydrofluoric acid and silane were applied, the risk of ceramic fracture increased. CONCLUSIONS: Acceptable levels of bond strength for clinical use were reached by all methods tested; however, liquid phosphoric acid etching followed by silane application (G2) resulted in the least damage to the ceramic surface. PMID:26352845

  19. Four chemical methods of porcelain conditioning and their influence over bond strength and surface integrity

    Directory of Open Access Journals (Sweden)

    João Paulo Fragomeni Stella

    2015-08-01

    Full Text Available OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding.METHODS: Four experimental groups (n = 13 were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid etching followed by silane application; G2 = 37% liquid phosphoric acid etching, no rinsing, followed by silane application; G3 = 10% hydrofluoric acid etching alone; and G4 = 10% hydrofluoric acid etching followed by silane application. After surface conditioning, metal brackets were bonded to porcelain by means of the Transbond XP system (3M Unitek. Samples were submitted to shear bond strength tests in a universal testing machine and the surfaces were later assessed with a microscope under 8 X magnification. ANOVA/Tukey tests were performed to establish the difference between groups (α= 5%.RESULTS: The highest shear bond strength values were found in groups G3 and G4 (22.01 ± 2.15 MPa and 22.83 ± 3.32 Mpa, respectively, followed by G1 (16.42 ± 3.61 MPa and G2 (9.29 ± 1.95 MPa. As regards surface evaluation after bracket debonding, the use of liquid phosphoric acid followed by silane application (G2 produced the least damage to porcelain. When hydrofluoric acid and silane were applied, the risk of ceramic fracture increased.CONCLUSIONS: Acceptable levels of bond strength for clinical use were reached by all methods tested; however, liquid phosphoric acid etching followed by silane application (G2 resulted in the least damage to the ceramic surface.

  20. Effects of 2 polishing techniques and reglazing on the surface roughness of dental porcelain.

    Science.gov (United States)

    Schneider, Jacqueline; Dias Frota, Bruna Marjorie; Passos, Vanara Florencio; Santiago, Sergio Lima; Freitas Pontes, Karina Matthes de

    2013-01-01

    The aim of this study was to compare the effect of 2 polishing systems and reglazing of dental porcelain through a quantitative and qualitative analysis of surface roughness using a stylus profilometer and scanning electron microscope. Fifteen porcelain specimens (10 x 3 x 3 mm) were used. On 1 surface of each block, a layer of glaze was applied, and surface roughness (Ra) was analyzed. All specimens were ground with aluminum oxide sandpaper until the shine was removed and the resulting Ra values were obtained. Afterwards, they were randomly divided into 3 treatment groups (n = 5): Group I (GI), polished with diamond-impregnated rubber wheels; Group II (GII), polished with silicon carbide-impregnated rubber wheels; and Group III (GIII), reglazed firing procedure alone. After the treatments, new Ra measurements were done. Data were submitted to analysis of variance (ANOVA), and Tukey tests at 5%. Comparisons between ground surface and treated surface were made by paired t-test. The ground and treated Ra values (µm) were determined as follows: GI: 0.66 ± 0.14, 0.35 ± 0.06; GII: 0.60 ± 0.04, 0.09 ± 0.03; and GIII: 0.67 ± 0.05, 0.75 ± 0.24. Significant differences were found between the ground and treated values for all groups. After the treatments, all groups differed statistically (P < 0.05). The silicon carbide system re-established the initial surface smoothness, while polishing with diamond-impregnated rubber or reglazing alone were not able to achieve a satisfactory smoothness.

  1. Porcelain versus composite inlays/onlays: effects of mechanical loads on stress distribution, adhesion, and crown flexure.

    Science.gov (United States)

    Magne, Pascal; Belser, Urs C

    2003-12-01

    This study used 2-D finite element modeling to simulate cuspal flexure and stresses at the surface and tooth-restoration interface of a restored maxillary molar using three restorative materials; the influence of four inlay/onlay preparation configurations on stress distribution within the complex was also investigated. A buccolingual cross-section of an intact molar was digitized and used to create 2-D models restored with different restorative materials (feldspathic porcelain, high- and low-elastic modulus composites) and tooth preparations (small and large inlays, small and large onlays). Two simulated 25-N oblique loads were applied to the cusps. The tangential stress for each finite element node located at the tooth surface, interfacial stress, and relative cuspal flexure were analyzed. All materials and tooth preparations exhibited similar surface tangential stress patterns, with a definite compressive area at the external cusp ridges, a tensile zone at the occlusal surface, and compression stress peaks at the CEJ. The low-elastic modulus composite showed reduced tensile stresses at its surface but increased tension at the dentin-adhesive interface when compared to ceramics. All types of onlays demonstrated a majority of compressive interfacial stresses, while inlays showed a majority of tensile stresses. The interfacial tension at the dentin level increased with the flexibility of the restorative material. Only the large ceramic onlay displayed almost pure compression at the interface. Composite-restored teeth exhibited increased crown flexure, while porcelain-restored teeth showed increased crown stiffness. Porcelain inlays/onlays featured more detrimental stresses at the occlusal surface but better potential protection against debonding at the dentin-restoration interface compared to composite inlays/onlays. Ceramic onlays/overlays seem to represent an effective answer to restore severely damaged posterior teeth.

  2. Er:YAG laser debonding of porcelain veneers

    Science.gov (United States)

    Buu, Natalie; Morford, Cynthia; Finzen, Frederick; Sharma, Arun; Rechmann, Peter

    2010-02-01

    The removal of porcelain veneers using Er:YAG lasers has not been previously described in the scientific literature. This study was designed to systematically investigate the efficacy of an Er:YAG laser on veneer debonding without damaging the underlying tooth structure, as well as preserving a new or misplaced veneer. Initially, Fourier Transform Infrared Spectroscopy (FTIR) was used on flat porcelain veneer samples (IPS Empress Esthetic; Ivoclar Vivadent, Amherst, NY) to assess which infrared laser wavelengths are transmitted through the veneer. Additionally, FTIR spectra from a veneer bonding cement (RelyX Veneer Cement A1; 3M ESPE, St. Paul, MN) were obtained. While the veneer material showed no characteristic water absorption bands in the FTIR, the bonding cement has a broad H2O/OH absorption band coinciding with the ER:YAG laser emission wavelength. Consequently Er:YAG laser energy transmission through different veneer thicknesses was measured. The porcelain veneers transmitted 11 - 18 % of the incident Er:YAG laser energy depending on their thicknesses (Er:YAG laser: LiteTouch by Syneron; wavelength 2,940 nm, 10 Hz repetition rate, pulse duration 100 μs at 133 mJ/pulse; straight sapphire tip 1,100 μm diameter; Syneron, Yokneam, Israel). Initial signs of cement ablation occurred at approximately 1.8 - 4.0 J/cm2. This can be achieved by irradiating through the veneer with the fiber tip positioned at a distance of 3-6 mm from the veneer surface, and operating the Er:YAG laser with 133 mJ output energy. All eleven veneers bonded on extracted anterior incisor teeth were easily removed using the Er:YAG laser. The removal occurred without damaging underlying tooth structure as verified by light microscopic investigation (Incident Light Microscope Olympus B 50, Micropublisher RTV 3.3 MP, Image Pro software, Olympus). The debonding mainly occurred at the cement/veneer interface. When the samples were stored in saline solution for 5 days and/or an air-waterspray was

  3. Predictable Outcomes with Porcelain Laminate Veneers: A Clinical Report.

    Science.gov (United States)

    Pimentel, Welson; Teixeira, Marcelo Lucchesi; Costa, Priscila Paganini; Jorge, Mônica Zacharias; Tiossi, Rodrigo

    2016-06-01

    This clinical report describes how to achieve predictable outcomes for anterior teeth esthetic restorations with porcelain laminate veneers by associating the digital planning and design of the restoration with interim restorations. The previous digital smile design of the restoration eliminates the communication barrier with the patient and assists the clinician throughout patient treatment. Interim restorations (diagnostic mock-ups) further enhance communication with the patient and prevent unnecessary tooth reduction for conservative tooth preparation. Adequate communication between patient and clinician contributes to successful definitive restorations and patient satisfaction with the final esthetic outcome.

  4. Thermoluminescence dating of the ancient Chinese porcelain using a regression method of saturation exponential in pre-dose technique

    Institute of Scientific and Technical Information of China (English)

    WANG; Weida; XIA; Junding; ZHOU; Zhixin

    2006-01-01

    This paper studies the thermoluminescence (TL) dating of the ancient porcelain using a regression method of saturation exponential in the pre-dose technique. The experimental results show that the measured errors are 15% (±1σ) for the paleodose and 17% (±1σ) for the annual dose respectively, and the TL age error is 23% (±1σ) in this method. The larger Chinese porcelains from the museum and the nation-wide collectors have been dated by this method. The results show that the certainty about the authenticity testing is larger than 95%, and the measurable porcelains make up about 95% of the porcelain dated. It is very successful in discrimination for the imitations of ancient Chinese porcelains. This paper describes the measured principle and method for the paleodose of porcelains. The TL ages are dated by this method for the 39 shards and porcelains from past dynasties of China and the detailed data in the measurement are reported.

  5. Partner selection supported by opaque reputation promotes cooperative behavior

    CERN Document Server

    Capraro, Valerio; Vilone, Daniele; Paolucci, Mario

    2016-01-01

    Reputation plays a major role in human societies, and it has been proposed as an explanation for the evolution of cooperation. While the majority of previous studies equate reputation with a transparent and complete history of players' past decisions, in real life, reputations are often based on personal evaluations, and so they are often ambiguous and opaque. For example, reputation has become central in online systems, in which history of others' past actions is not available, and sources are unknown, as well as the metrics used for the evaluation. Using web-based experiments, we explore the extent to which obscure reputation works in isolating defectors, and whether it can promote cooperative behaviors. Our results show that subjects cooperate much less with low-reputation partners than with medium- or high-reputation ones, even if they know nothing about the way in which that reputation was gained. Next, we explore whether the mere awareness of being evaluated leads people to change their behavior. We fin...

  6. Dynamical friction on hot bodies in opaque, gaseous media

    CERN Document Server

    Masset, Frédéric S

    2016-01-01

    We consider the gravitational force exerted on a point-like perturber of mass $M$ travelling within a uniform gaseous, opaque medium at constant velocity $V$. The perturber irradiates the surrounding gas with luminosity $L$. The diffusion of the heat released is modelled with a uniform thermal diffusivity $\\chi$. Using linear perturbation theory, we show that the force exerted by the perturbed gas on the perturber differs from the force without radiation (or standard dynamical friction). Hot, underdense gas trails the mass, which gives rise to a new force component, the heating force, with direction $+V$, thus opposed to the standard dynamical friction. In the limit of low Mach numbers, the heating force has expression $F_\\mathrm{heat}=\\gamma(\\gamma-1)GML/(2\\chi c_s^2)$, $c_s$ being the sound speed and $\\gamma$ the ratio of specific heats. In the limit of large Mach numbers, $F_\\mathrm{heat}=(\\gamma-1)GML/(\\chi V^2)f(r_\\mathrm{min}V/4\\chi)$, where $f$ is a function that diverges logarithmically as $r_\\mathrm{...

  7. White cells facilitate opposite- and same-sex mating of opaque cells in Candida albicans.

    Directory of Open Access Journals (Sweden)

    Li Tao

    2014-10-01

    Full Text Available Modes of sexual reproduction in eukaryotic organisms are extremely diverse. The human fungal pathogen Candida albicans undergoes a phenotypic switch from the white to the opaque phase in order to become mating-competent. In this study, we report that functionally- and morphologically-differentiated white and opaque cells show a coordinated behavior during mating. Although white cells are mating-incompetent, they can produce sexual pheromones when treated with pheromones of the opposite mating type or by physically interacting with opaque cells of the opposite mating type. In a co-culture system, pheromones released by white cells induce opaque cells to form mating projections, and facilitate both opposite- and same-sex mating of opaque cells. Deletion of genes encoding the pheromone precursor proteins and inactivation of the pheromone response signaling pathway (Ste2-MAPK-Cph1 impair the promoting role of white cells (MTLa in the sexual mating of opaque cells. White and opaque cells communicate via a paracrine pheromone signaling system, creating an environment conducive to sexual mating. This coordination between the two different cell types may be a trade-off strategy between sexual and asexual lifestyles in C. albicans.

  8. 78 FR 31575 - Certain Opaque Polymers, Notice of Receipt of Complaint; Solicitation of Comments Relating to the...

    Science.gov (United States)

    2013-05-24

    ... Doc No: 2013-12372] INTERNATIONAL TRADE COMMISSION [Docket No 2957] Certain Opaque Polymers, Notice of... Commission has received a complaint entitled Certain Opaque Polymers, DN 2957; the Commission is soliciting... importation, and the sale within the United States after importation of certain opaque polymers. The...

  9. Bonding of dental porcelain to non-cast titanium with different surface treatments.

    Science.gov (United States)

    Lin, Mau-Chin; Tung, Kuo-Lung; Lin, Sheng-Chieh; Huang, Her-Hsiung

    2012-01-01

    This study investigated the bonding of dental porcelain to non-cast Ti surface with different treatments. Mechanically ground non-cast Ti strips, simulating surface conditions produced by CAD/CAM, were Al(2)O(3)-sandblasted, then subjected to different surface treatments, including immersion in HNO(3)-containing acid, NaOH-containing alkaline, and NaOH-containing alkaline then HNO(3)-containing acid. Ti-porcelain specimens preparations and their bend strength measurements were based on ISO 9693. Ti surface treatment changed not only surface roughness but also surface chemistry, leading to influence on bond strength. Bond strengths of all Ti-porcelain groups were higher than ISO 9693 minimum requirement. The sandblasted/acid-treated Ti surface showed the highest bond strength (34.60 MPa) with porcelain; no significant difference in bond strength (27.92-29.63 MPa) was found among other Tiporcelain groups. All Ti-porcelain specimens showed adhesive bond failure. Bonding between non-cast Ti and dental porcelain was strengthened by a simple and practical sandblasting/acid-etching treatment of the Ti surface prior to porcelain sintering.

  10. Al2O3/GdAlO3 fiber for dental porcelain reinforcement.

    Science.gov (United States)

    Medeiros, Igor S; Luz, Luciana A; Yoshimura, Humberto N; Cesar, Paulo F; Hernandes, Antonio C

    2009-10-01

    The aim of this study was to test the hypothesis that the addition of continuous or milled GdAlO3/Al2O3 fibers to a dental porcelain increases its mechanical properties. Porcelain bars without reinforcement (control) were compared to those reinforced with long fibers (30 vol%). Also, disk specimens reinforced with milled fibers were produced by adding 0 (control), 5 or 10 vol% of particles. The reinforcement with continuous fibers resulted in significant increase in the uniaxial flexural strength from 91.5 to 217.4 MPa. The addition of varied amounts of milled fibers to the porcelain did not significantly affect its biaxial flexural strength compared to the control group. SEM analysis showed that the interface between the continuous fiber and the porcelain was free of defects. On the other hand, it was possible to note the presence of cracks surrounding the milled fiber/porcelain interface. In conclusion, the reinforcement of the porcelain with continuous fibers resulted in an efficient mechanism to increase its mechanical properties; however the addition of milled fibers had no significant effect on the material because the porcelain was not able to wet the ceramic particles during the firing cycle.

  11. Influence of bruxism on survival of porcelain laminate veneers

    Science.gov (United States)

    Agustín-Panadero, Rubén; Fons-Font, Antonio; Román-Rodríguez, Juan L.; Solá-Ruíz, María F.

    2014-01-01

    Objectives: This study aims to determine whether bruxism and the use of occlusal splints affect the survival of porcelain laminate veneers in patients treated with this technique. Material and Methods: Restorations were made in 70 patients, including 30 patients with some type of parafunctional habit. A total of 323 veneers were placed, 170 in patients with bruxism activity, and the remaining 153 in patients without it. A clinical examination determined the presence or absence of ceramic failure (cracks, fractures and debonding) of the restorations; these incidents were analyzed for association with bruxism and the use of splints. Results: Analysis of the ceramic failures showed that of the 13 fractures and 29 debonding that were present in our study, 8 fractures and 22 debonding were related to the presence of bruxism. Conclusions: Porcelain laminate veneers are a predictable treatment option that provides excellent results, recognizing a higher risk of failure in patients with bruxism activity. The use of occlusal splints reduces the risk of fractures. Key words:Veneer, fracture, debonding, bruxism, occlusal splint. PMID:23986018

  12. On the Friction and Wear Behaviors of Dental Machinable Porcelain

    Institute of Scientific and Technical Information of China (English)

    YU Hai-yang; ZHOU Zhong-rong; CAI Zhen-Bing

    2004-01-01

    In order to well design tribosystems of dental CAD-CAM restorations, an understanding of the tribological mechanisms of dental machinable porcelain are essential. The friction and wear behavior of new generation industrially prefabricated Cerec Vitablocs Mark Ⅱ against uniform Si3N4 ball has been performed using a small amplitude reciprocating apparatus under simulating oral conditions. The loads of 10-40 N, reciprocating amplitudes of 100-500 μm, frequencies of 1-4 Hz and two lubrications (no / artificial saliva lubrication) were selected. Tests lasting up to 10 000 cycles were conducted. The results show that Cerec Vitablocs Mark Ⅱ record a friction coefficient of 0.55-0.84. Artificial saliva plays a lubricant effect during wear process. Among three parameters of the test on friction coefficient and wear depth of dental machinable porcelains, the load effect is prominent. Abrasive wear is the main wear mechanism, but brittle cracks and delamination are more popular especially under unlubricated friction.

  13. On the Friction and Wear Behaviors of Dental Machinable Porcelain

    Institute of Scientific and Technical Information of China (English)

    YUHai-yang; ZHOUZhong-rong; CAIZhen-Bing

    2004-01-01

    In order to well design tribosystems of dental CAD-CAM restorations, an understanding of the tribological mechanisms of dental machinable porcelain are essential. The friction and wear behavior of new generation industrially prefabricated Cerec Vitablocs Mark II against uniform Si3N4ball has been performed using a small amplitude reciprocating apparatus under simulating oral conditions. The loads of 10-40N, reciprocating amplitudes of 100-500μm, frequencies of 1-4Hz and two lubrications (no / artificial saliva lubrication) were selected. Tests lasting up to 10 000 cycles were conducted. The results show that Cerec Vitablocs Mark Ⅱ record a friction coefficient of 0.55-0.84. Artificial saliva plays a lubricant effect during wear process. Among three parameters of the test on friction coefficient and wear depth of dental machinable porcelains, the load effect is prominent. Abrasive wear is the main wear mechanism, but brittle cracks and delamination are more popular especially under unlubricated friction.

  14. Evaluation of Saudi pegmatite and its use in porcelain industry

    Directory of Open Access Journals (Sweden)

    Hassan M.H. Al-Marzouki

    2012-09-01

    Full Text Available Pegmatite is the main source of feldspar for ceramics industry. Usage of pegmatite in ceramic industry causes some problems due to the presence of mica and iron oxides. These materials reduce tile strength, hardness and density of the final product leading to low quality ceramic products. Southern Saudi pegmatite separation treatment was carried out in two phases in order to improve the ceramic quality of the feldspar obtained from this pegmatite. The first phase consists of gravitational separation to remove the heavy impurities and in the second phase magnetic separation was carried out to further minimize iron content. Porcelain ceramic batches were prepared by wet-mixing, drying, pressing (semi-dry press and fired at temperatures from 1000 to 1350 °C. The porcelain ceramic bodies were prepared and examined by DTA, X-ray diffraction, SEM and tested for bulk density, linear shrinkage, water absorption and flexural strength. These results indicated that, after treatment (gravity and magnetic separation, the pegmatite can be considered as a good source of potash feldspar. The present study provides a positive indication for using of Southern Saudi pegmatite after treatment in ceramic industries.

  15. THE USE OF PORCELAIN IN CONTEMPORARY JEWLERY DESIGN

    Directory of Open Access Journals (Sweden)

    Sibel Sıdıka Sevim

    2016-04-01

    Full Text Available Jewelry has been used for the purposes of belief, magic, protection or ornamentation since the day the human beings have existed. The phenomenon of jewelry has changed with developing and changing ages and has gained a different meaning in each period. Jewelry gained meaning and a place in the history sometimes with its design and sometimes with the materials used. Concepts of art and craft towards which our point of view changed with the industrial revolution intertwined in time and new formations occurred. Jewelry and jewel had been accepted as crafts from the ancient times to the 18th century, after the 18th century, jewelry succeeded to be accepted as an art and gained a place in the history of contemporary art. With the works of the artists, the design of jewelry improved and had very important progress. In the lights of all these formations, when someone thinks about the design of jewelry, one of the elements that comes to mind is the original jewelry that is produced with different materials. Classical jewelry on which just precious metals and stones are used gives place to special designs which are more modern, unlimitedly composed with every kind of materials. In this article, the use of porcelain in the boundless contemporary design of jewelry is going to be mentioned and examples are going to be presented from the works of modern jewelry designers who use porcelain.

  16. Neutron activation analysis and Mossbauer spectroscopy research on coloring mechanism of Chinese Ru porcelain

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The characteristic spectrum and its main wavelength of Ru porcelain glaze are measured by color difference instrument to determine the relations between glaze color and its main wavelength. The content of the 30 coloring elements in Ru porcelain is determined by neutron activation analysis (NAA), which showed that iron is the major coloring element. M?ssbauer spectroscopy analysis shows that the iron element in the glaze exists in the form of structural iron (Fe2+, Fe3+). The quantitative relationship between the main wavelength of glaze in various colors and the relative content of structural iron (Fe2+/Fe3+) is determined. Thus the coloring mechanism of Ru porcelain is investigated entirely.

  17. Dynamical friction on hot bodies in opaque, gaseous media

    Science.gov (United States)

    Masset, Frédéric S.; Velasco Romero, David A.

    2017-03-01

    We consider the gravitational force exerted on a point-like perturber of mass M travelling within a uniform gaseous, opaque medium at constant velocity V. The perturber irradiates the surrounding gas with luminosity L. The diffusion of the heat released is modelled with a uniform thermal diffusivity χ. Using linear perturbation theory, we show that the force exerted by the perturbed gas on the perturber differs from the force without radiation (or standard dynamical friction). Hot, underdense gas trails the mass, which gives rise to a new force component, the heating force, with direction +V, thus opposed to the standard dynamical friction. In the limit of low Mach numbers, the heating force has expression F_heat=γ (γ -1)GML/(2χ c_s^2), cs being the sound speed and γ the ratio of specific heats. In the limit of large Mach numbers, Fheat = (γ - 1)GML/(χV2)f(rminV/4χ), where f is a function that diverges logarithmically as rmin tends to zero. Remarkably, the force in the low Mach number limit does not depend on the velocity. The equilibrium speed, when it exists, is set by the cancellation of the standard dynamical friction and heating force. In the low Mach number limit, it scales with the luminosity-to-mass ratio of the perturber. Using the above results suggests that Mars- to Earth-sized planetary embryos heated by accretion in a gaseous protoplanetary disc should have eccentricities and inclinations that amount to a sizeable fraction of the disc's aspect ratio, for conditions thought to prevail at a few astronomical units.

  18. A method to measure internal contact angle in opaque systems by magnetic resonance imaging.

    Science.gov (United States)

    Zhu, Weiqin; Tian, Ye; Gao, Xuefeng; Jiang, Lei

    2013-07-23

    Internal contact angle is an important parameter for internal wettability characterization. However, due to the limitation of optical imaging, methods available for contact angle measurement are only suitable for transparent or open systems. For most of the practical situations that require contact angle measurement in opaque or enclosed systems, the traditional methods are not effective. Based upon the requirement, a method suitable for contact angle measurement in nontransparent systems is developed by employing MRI technology. In the Article, the method is demonstrated by measuring internal contact angles in opaque cylindrical tubes. It proves that the method also shows great feasibility in transparent situations and opaque capillary systems. By using the method, contact angle in opaque systems could be measured successfully, which is significant in understanding the wetting behaviors in nontransparent systems and calculating interfacial parameters in enclosed systems.

  19. Shear bond strength between porcelain and nano filler composite resin with or without 9% hydrofluoric acid etching

    Directory of Open Access Journals (Sweden)

    Kun Ismiyatin

    2009-06-01

    Full Text Available Background: Reparation technique on restorations with broken or damaged porcelain which are still attached with the teeth are difficult, because it is very hard to remove the porcelain restoration without damaging it, and it needs a long time. Various ways have been developed to repair the broken porcelain, one of them is the use of composite resin as the material for the restoration of fractured porcelain. Repairing porcelain inside the mouth without removing the restoration of the damaged porcelain using light cured composite resins material seems to be an advantageous option because it is relatively simple, has low risks, good esthetically and cheap. Purpose: The objective of this study was to find out the difference of shear bond strength in porcelain reparation using nano filler composite resin with or without 9% hydrofluoric acid etching by using Autograph measuring device. Methods: Twenty pieces of the porcelain samples devided into 2 groups. Group I: etching process using 9% hydrofluoric acid, and group II : without etching process. Result: The data was analyzed using t test in a p value of 0.0001 (p≤0.05, which means there is a significant different of shear bond strength between treated group I and II. The biggest shear bond strength was in treatment group I. Conclusion: The use of 9% hydrofluoric acid on the surface of porcelain can increase the shear bond strength between porcelain and nano filler composite resin.

  20. Preparation and Evaluation of Dental Resin with Antibacterial and Radio-Opaque Functions

    OpenAIRE

    Pekka K. Vallittu; Lippo V. J. Lassila; Jingwei He; Eva Söderling

    2013-01-01

    In order to prepare antibacterial and radio-opaque dental resin, a methacrylate monomer named 2-Dimethyl-2-dodecyl-1-methacryloxyethyl ammonium iodine (DDMAI) with both antibacterial and radio-opaque activities was added into a 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropyl)-phenyl]propane (Bis-GMA)/methyl methacrylate (MMA) dental resin system. Degree of conversion (DC), flexural strength (FS) and modulus (FM), water sorption (WS) and solubility (WSL), antibacterial activity, and radio-opacity...

  1. "Porcelain heart" cardiomyopathy secondary to hyperparathyroidism: radiographic, echocardiographic, and cardiac CT appearances.

    LENUS (Irish Health Repository)

    Freeman, James

    2010-11-01

    We report the radiographic, echocardiographic and cardiac CT appearances of \\'porcelain heart\\' in an 85-year-old woman who presented with progressive heart failure. The extensive myocardial calcification was secondary to hyperparathyroidism with renal failure.

  2. "Porcelain heart" cardiomyopathy secondary to hyperparathyroidism: radiographic, echocardiographic, and cardiac CT appearances.

    LENUS (Irish Health Repository)

    Freeman, James

    2012-02-01

    We report the radiographic, echocardiographic and cardiac CT appearances of \\'porcelain heart\\' in an 85-year-old woman who presented with progressive heart failure. The extensive myocardial calcification was secondary to hyperparathyroidism with renal failure.

  3. Procedure for combining a facial porcelain veneer with a metal lingual and occluding surface.

    Science.gov (United States)

    Bishop, K; Priestley, D

    1996-04-01

    This article describes a procedure for making a crown that combines an all-porcelain facial veneer with a metal lingual and occluding surface. The procedure combines both the conventional lost wax technique and the use of a refractory cast for firing porcelain. The crown retains the advantages of the traditional all-porcelain crown restoration but reduces the risk of damage to the opposing teeth associated with an all-ceramic occluding surface. Furthermore, compared with porcelain, the metal surface allows more control over the occlusal and lingual contours during construction of the crown. Although the construction of the anterior crown is described, the procedure is equally applicable to posterior full-coverage restorations.

  4. Contribution of infrared microscopy to studies of fluid inclusions hosted in some opaque ore minerals: possibilities, limitations, and perspectives

    Science.gov (United States)

    Lüders, Volker

    2016-11-01

    During the past two decades, several studies of fluid inclusions hosted in some opaque ore minerals using near-infrared microscopy have been performed. Results indicated that this method can be applied to several sulfidic ores and metal oxides depending on their electronic band structures and infrared-active vibration modes. Infrared transmittance of individual ore minerals can be best characterized using Fourier transform infrared spectroscopy. Infrared microscopic observations are limited to the near-infrared region to about 2.3 μm depending on the IR sensitivity of the IR camera. The trace element content in ore minerals can be another limiting factor for optical observations in near-infrared light. Still, IR transmittance gradually decreases upon heating caused by shifting of IR absorption edges for higher wavelengths. Possibilities and limitations of studying fluid inclusions hosted in opaque minerals by near-infrared light microthermometry and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) are discussed.

  5. Analysis of elemental composition of porcelains unearthed from Waguantan kiln site by PIXE–RBS

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Z. [Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064 (China); Zhang, K. [School of History and Culture, Sichuan University, Chengdu 610064 (China); Xia, C.D.; Liu, M.T.; Zhu, J.J. [Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064 (China); An, Z., E-mail: anzhu@scu.edu.cn [Key Laboratory of Radiation Physics and Technology of Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064 (China); Bai, B., E-mail: baibin@scu.edu.cn [School of History and Culture, Sichuan University, Chengdu 610064 (China)

    2015-03-01

    Highlights: •We analyzed 61 unearthed porcelain shards in Yuan Dynasty by PIXE–RBS. •An electron gun was installed to solve the electric charge accumulations. •The factor analysis was performed for the element compositions. •The “exotic group” porcelain samples unearthed were produced locally. -- Abstract: A method combining proton-induced X-ray emission spectrometry (PIXE) and Rutherford backscattering spectrometry (RBS) was used to determine the composition of 61 porcelain shards from the Yuan Dynasty (1271–1368 A.D.) unearthed from the Waguantan kiln site at Tianzhu County in Guizhou Province, China. Based on our previous experimental setup, an electron gun device with a LaB{sub 6} crystal cathode was installed to solve the problem created when the incident proton beams generated electric charge accumulations on the surfaces of the insulating porcelain samples, which induced a large bremsstrahlung background. The use of the electron gun has largely eliminated the large bremsstrahlung background and has therefore improved the detection limits for elements, especially for trace elements, and made it possible to determine the origin of the porcelains based on the trace elements. Major and trace elemental compositions of the porcelain bodies and glazes measured by PIXE and RBS were analyzed by the factor analysis method. The factor analysis showed that a few pieces of porcelain with a style similar to the porcelain of the Longquan kiln among the unearthed porcelains from the Waguantan kiln site did not have obvious differences in elemental compositions from other remaining porcelains unearthed from the Waguantan kiln site, indicating that the pieces of unearthed porcelain with the Longquan kiln style did in fact belong to the product fired locally by imitating the model of the Longquan celadon with local raw materials. This result therefore indicated that the Longquan kiln technology that originated from the Five Dynasties (907–960 A.D.) had been

  6. Elaboration of porcelain stoneware tiles at 1170 C by addition of wollastonite

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Munoz, L.; Carda, J.B. [Universitat Jaume I, Castellon (Spain). Dept. Quimica Inorganica y Organica; Cerisuelo, E. [Tierra Atomizada S.A., Alcora, Castellon (Spain); Tuduri, F. [Arcillas Blanches ABSA, Madrid (Spain); Plaza, S. [Co. Minera Ilustracion, Salamanca (Spain)

    2002-07-01

    The conventional procedure for the manufacture of porcelain stoneware tiles requires high-temperature kilns. In this work, the possibility to reduce the firing temperature and consequently, to use conventional-type kilns for porcelain stoneware tiles is shown. With a particular selected composition prepared with wollastonite as an additive, a decrease of about 40 C was achieved. The effect of the wollastonite addition consists in the reduction of the closed porosity and therefore the water absorption. (orig.)

  7. A Study on Provisional Cements, Cementation Techniques, and Their Effects on Bonding of Porcelain Laminate Veneers

    OpenAIRE

    Vinod Kumar, G.; Soorya Poduval, T.; Bipin Reddy; Shesha Reddy, P.

    2013-01-01

    Minimal tooth preparation is required for porcelain laminate veneers, but interim restorations are a must to protect their teeth against thermal insult, chemical irritation, and to provide aesthetics. Cement remaining after the removal of the provisional restoration can impair the etching quality of the tooth surface and fit and final bonding of the porcelain laminate veneer. This in vitro study examined the tooth surface for remaining debris of cement after removal of a provisional restorati...

  8. Analyzing the effect of ion exchange on flexural strength of cermaco II and colorlogic veneer porcelains

    OpenAIRE

    N. Rashidan; HA. Mahgoli

    1998-01-01

      The major foible of dental ceramics is their brittle nature. Therefore, the producers of these materials have focused on the “strength” issue. A method of increasing strength is ion exchange on porcelain surface which leads to formation of a compressive crust that opposing forces should overcome before developing a crack. In current study, ion exchange in two types of porcelain, Ceramco II which is used in PFM restorations and Colorloic veneer which is used for laminates, veneers, inlays an...

  9. COMPARISON OF THE SHEAR BOND STRENGTH OF BRACKETS USING TWO SURFACE CONDITIONING METHODS FOR PORCELAIN

    OpenAIRE

    Ballesteros-Pinzón, Claudia; Bermúdez-Lozano, Jesús A.; Coronel-Corzo, Nelly; de-León-Goenaga, Edwin; Delgado, Linda P.; Báez-Quintero, Liliana

    2014-01-01

    Introduction: During 2010 the degree research “Comparison of the shear bond strength of brackets using two surface conditioning methods for porcelain” was carried out at Universidad Cooperativa de Colombia in Bogota. Objective: To determine the shear bond strength of metal brackets cemented on porcelain using two surface conditioning methods. Materials and methods: Forty human premolars were used and prepared for further cementing porcelain-metal crowns. There were two groups of 20 teeth each...

  10. Flexural strength of fluorapatite-leucite and fuorapatite porcelains exposed to erosive agents in cyclic immersion

    Directory of Open Access Journals (Sweden)

    Peerapong Junpoom

    2011-04-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the fexural strength of two porcelain materials (IPS d.SIGN and IPS e.max Ceram exposed to erosive agents. MATERIAL AND METHODS: One hundred and twenty bar-shaped specimens were made from each of fuorapatite-leucite porcelain (IPS d.SIGN and fuorapatite porcelain (IPS e.max Ceram and divided into 8 groups of 15 specimens each. Six groups were alternately immersed in the following storage agents for 30 min: deionized water (control, citrate buffer solution, pineapple juice, green mango juice, cola soft drink and 4% acetic acid. Then, they were immersed for 5 min in deionized water at 37ºC. Seven cycles were completed, totalizing 245 min. A 7th group was continuously immersed in 4% acetic acid at 80ºC for 16 h. The final, 8th, group was stored dry at 37ºC for 245 min. Three-point bending tests were performed in a universal testing machine. The data were analyzed statistically by 2-way ANOVA, Tukey's HSD test and t-test at signifcance level of 0.05. RESULTS: The fexural strengths of all groups of each porcelain after exposure to erosive agents in cyclic immersion did not differ signifcantly (p>0.05. For both types of porcelain, dry storage at 37ºC yielded the highest fexural strength, though without signifcant difference from the other groups (p>0.05. The fexural strengths of all groups of fuorapatite porcelains were signifcantly higher (p<0.05 than those of the fuorapatite-leucite porcelains. CONCLUSIONS: This study demonstrated that the erosive agents evaluated did not affect the fexural strength of the tested dental porcelains.

  11. Clinical and scanning electron microscopic assessments of porcelain and ceromer resin veneers.

    OpenAIRE

    Dhawan P; Prakash H; Shah N

    2003-01-01

    PURPOSE: Recently available Ceromer resin materials are promising for fabrication of esthetic anterior laminates and provices an alternative, cost effective treament modality to porcelain laminates for discolored anterior anterior teeth. It was proposed to study the esthetic quality and surface finish of veneers fbricated from ceromer resin and compare it with the standard porcelain veneers, both clinically as well as by scanning electron microscope (SEM) at baseline and at 12 months. If foun...

  12. Preparation of porcelain tile granulates by more environmentally sustainable processes

    Directory of Open Access Journals (Sweden)

    García-Ten, J.

    2012-04-01

    Full Text Available This study examines the feasibility of manufacturing glazed porcelain tiles with a more environmentally friendly manufacturing process, by reducing water and thermal energy consumption. The process studied in this paper is dry milling in a pendulum mill, with subsequent granulation (in order to obtain a press powder with similar flowability to that of spraydried powders. The different morphology of the new granulate with respect to the standard spray-dried granulate modifies the microstructure of the green compacts and thus, their behaviour and fired tile properties. In order to obtain porcelain tiles with the required properties (water absorption, mechanical strength,… changes have been made in the raw materials mixture and in the processing variables. Finally, porcelain tiles measuring 50x50 cm have been manufactured at industrial scale with the new granulate using a conventional firing cycle, obtaining quality levels identical to those provided by the spray-dried granulate. These results open the possibility of preparing porcelain tile body compositions through a manufacturing process alternative to the standard one, more environmentally friendly and with lower costs.

    En el presente trabajo se ha estudiado la viabilidad de fabricar gres porcelánico esmaltado utilizando un sistema de preparación de la composición del soporte más respetuoso con el medio ambiente, lo que implica una reducción importante de los consumos de agua y de energía térmica. El proceso que se estudia en el presente trabajo es el consistente en la molienda vía seca en molino pendular y en la posterior granulación (para obtener un polvo de prensas con fluidez similar a la de los polvos atomizados. La distinta morfología de los nuevos gránulos obtenidos respecto al polvo atomizado actual, modifica la microestuctura en crudo de las piezas y, con ello, el comportamiento y propiedades finales de las baldosas obtenidas. Por ello, ha sido necesario

  13. Effect of preoxidation on the bond strength of titanium and porcelain.

    Science.gov (United States)

    Mahale, K M; Nagda, S J

    2014-06-01

    The purpose of this study was to investigate the effect of preoxidation on porcelain titanium- bond strength and the effect of paste bonder (adhesive) on the titanium porcelain bond strength. 11 specimens of commercially pure titanium (26 x 7 x 3 mm) were prepared by different heat treatments in programmable dental furnace. Identification of the oxides formed on the metal surface was conducted with an X-Ray diffractometer with CuKalpha radiation. Vickers hardness numbers were determine. Additional 50 specimens of commercially pure titanium were used to bond with low fusing porcelain. The bond strength was measured in a universal testing machine. X-ray diffraction analysis of the surface of pure titanium revealed that the relative peak intensity of alpha -Ti decreased and that of TiO2 increased with increasing firing temperature. The Vickers hardness number decreased initially as the temperature increased but it increased remarkably above 900 degrees C & was harder in air than vacuum. The tensile shear bond strength was highest in the green stage i.e. without preoxidation of metal, and decreased above 900 degrees C, and was the lowest in the group without paste bonder application. The difference in bond strengths was statistically highly significant for all groups. Preoxidation under vacuum before porcelain firing can effectively improve bonding. The adhesive provided with the low fusing porcelain helps in the bond between titanium & porcelain.

  14. Bonding to a porcelain surface: Factors affecting the shear bond strength

    Directory of Open Access Journals (Sweden)

    Shishir Singh

    2013-01-01

    Full Text Available Objectives: Bonding to porcelain veneers, crowns or restorations is a major challenge for an orthodontist. A study was undertaken wherein, the shear bond strengths of metal and ceramic brackets on porcelain were compared and the effects of debonding on the debonded surfaces were evaluated. Materials and Methods: A total of 50 acrylic duplicate samples were fabricated from a therapeutically extracted maxillary first premolar, duly prepared for metal crown with porcelain facing. The samples were divided into two equal groups for bonding of metal and ceramic brackets. The shear bond strength of the samples was measured with a universal testing machine. Results: The metal brackets showed shear bond strengths with a mean of 12.21 ± 1.4 MPa, whereas the ceramic brackets displayed shear bond strengths with a mean of 17.45 ± 2.36 MPa. Visual and scanning electron microscope examination revealed multiple failure patterns with more of porcelain fractures in the ceramic brackets group. Conclusion: Bonding of metal and ceramic brackets to porcelain can be achieved with bond strengths comparable to that when bonded to enamel surface. Porcelain fractures are more commonly associated with debonding of ceramic brackets.

  15. Measuring residual stress in ceramic zirconia-porcelain dental crowns by nanoindentation.

    Science.gov (United States)

    Zhang, Y; Allahkarami, M; Hanan, J C

    2012-02-01

    Residual stress plays a critical role in failure of ceramic dental crowns. The magnitude and distribution of residual stress in the crown system are largely unknown. Determining the residual stress quantitatively is challenging since the crown has such complex contours and shapes. This work explored the feasibility and validity of measuring residual stress of zirconia and porcelain in ceramic crowns by nanoindentation. Nanoindentation tests were performed on the cross-section of a crown for both porcelain and zirconia along four critical locations: the thickest, thinnest and medium porcelain thicknesses. Zirconia and porcelain pieces, chipped off from the crown and annealed at 400 °C, were used as reference samples. The residual stress was determined by comparing the measured hardness of the stressed sample with that of the reference sample. Nanoindentation impression images were acquired through a scanning probe microscope (SPM) equipped with a Hysitron Triboindenter. Zirconia showed large pile-up. Residual stress is determined along the thickness of crowns at the chosen locations for both porcelain and zirconia. The measured results were compared with the results from X-ray diffraction (XRD) and finite element modeling (FEM). Results show there are large amounts of residual stresses in the dental crown and their magnitude differs between locations due to the complex shape of the crown. The average residual stress readings were as high as -637 MPa and 323 MPa for zirconia and porcelain respectively.

  16. Decoration of natural porcelain stoneware with organometalic applications

    Directory of Open Access Journals (Sweden)

    Portolés, J.

    2000-02-01

    Full Text Available The objectives aimed at could be summarised as the obtaining of a new Porcelain Stoneware product which, taking into account this material technical and esthetical attributes, emphasises those characteristics in a significant way, and provides it with new very interesting values. The working lines followed were focussed on the improvement of the technical qualities inherent to Natural Porcelain Stoneware, attributing to it, at the same time, characteristics only present, until now, in the polished material. New decorative applications have been also defined which allow the simultaneous comparison of aesthetic definitions together with a maintenance of its qualities, something never done before with this type of product.

    Los objetivos perseguidos se podrían resumir como la obtención de un nuevo producto de Gres Porcelánico que, teniendo en cuenta los atributos técnicos y estéticos de este material, potencie estas características de manera significativa y le confiera nuevos valores de gran interés. Las líneas de trabajo realizadas se han concretado en la mejora de las prestaciones técnicas inherentes al Gres Porcelánico Natural, atribuyéndole, al mismo tiempo, características hasta ahora solo presentes en el material pulido. Al mismo tiempo, se han definido nuevas aplicaciones decorativas que posibilitan la compartición simultánea de definiciones estéticas, hasta ahora no logradas con este tipo de producto, con un mantenimiento de las prestaciones del mismo.

  17. Porcelainized stoneware: architectural, processing and physico-mechanical properties

    Directory of Open Access Journals (Sweden)

    Manfredini, T.

    1996-06-01

    Full Text Available Porcelainized stoneware is an extremely hard and homogeneous unglazed ceramic material obtained by fastfiring of kaolinitic ceramic bodies containing a large amount of fluxes. The obtained tiles, available in a large variety of colours, shape size and surface finish, are characterized by very low porosity (<0,3wt% expressed as water absorption and are ideal for heavy-traffic areas subject to mechanical and chemical stresses. Porcelainized stoneware tiles offer alternative valid (and in many cases necessary solutions to the traditional glazed tiles either for interiors or for exteriors both in modern or classic constructions for flooring and covering.

    El gres porcelánico es un material cerámico muy duro y homogéneo, no vidriado en su superficie, obtenido por cocción rápida de composiciones ricas en caolinita, conteniendo una gran cantidad de fundentes. Las plaquetas de pavimentos que se obtienen son de una variedad muy extensa en aspectos, diseños y colores, caracterizándose, fundamentalmente, por su muy baja porosidad (<0,3wt%, expresado en porcentaje de capacidad de absorción de agua. Estos materiales son ideales para tráfico pesado en áreas sujetas a intensas tensiones mecánicas y químicas. El gres porcelánico ofrece alternativas válidas (y, en muchos casos, soluciones necesarias a los pavimentos vidriados tradicionales, en interiores o para usos exteriores, ambos con decoraciones modernas o clásicas para suelos o recubrimientos de paredes.

  18. 牡丹瓷与中原陶瓷的发展%Peony Porcelain and Development of Porcelain in the Central Plain

    Institute of Scientific and Technical Information of China (English)

    贾晓莉

    2014-01-01

    陶瓷作为我国一项伟大发明,历史悠久,凝聚着中华民族智慧的结晶,是中华民族对人类社会文明发展的重大贡献。洛阳作为世界著名文化古都,长期以来是中国古代的政治、经济、文化中心,在中国陶瓷的发展历史上有着举足轻重的地位。在传承中国古代陶瓷技艺尤其是唐白瓷、唐三彩制作技艺的基础上,依托河洛地区出土和传世且有牡丹纹饰的三彩陶瓷器,形成了一种用手工制作而成的新派艺术陶瓷---牡丹瓷。%Porcelain, a great invention of China, has a long history, and crystallized the wisdom of the Chi-nese nation , The invention of porcelain is a significant contribution to the development of human civilization .Luoy-ang is a world famous ancient city , has long been the political , economic and cultural center of ancient China , has the pivotal status in the development of Chinese porcelain .In the tradition of ancient Chinese porcelain technology , especially on the basis of the white porcelain , Tang tri-colored glazed pottery , a new hand made artistic porcelain has been created .

  19. pH Regulates White-Opaque Switching and Sexual Mating in Candida albicans.

    Science.gov (United States)

    Sun, Yuan; Cao, Chengjun; Jia, Wei; Tao, Li; Guan, Guobo; Huang, Guanghua

    2015-11-01

    As a successful commensal and pathogen of humans, Candida albicans encounters a wide range of environmental conditions. Among them, ambient pH, which changes frequently and affects many biological processes in this species, is an important factor, and the ability to adapt to pH changes is tightly linked with pathogenesis and morphogenesis. In this study, we report that pH has a profound effect on white-opaque switching and sexual mating in C. albicans. Acidic pH promotes white-to-opaque switching under certain culture conditions but represses sexual mating. The Rim101-mediated pH-sensing pathway is involved in the control of pH-regulated white-opaque switching and the mating response. Phr2 and Rim101 could play a major role in acidic pH-induced opaque cell formation. Despite the fact that the cyclic AMP (cAMP) signaling pathway does not play a major role in pH-regulated white-opaque switching and mating, white and opaque cells of the cyr1/cyr1 mutant, which is defective in the production of cAMP, showed distinct growth defects under acidic and alkaline conditions. We further discovered that acidic pH conditions repressed sexual mating due to the failure of activation of the Ste2-mediated α-pheromone response pathway in opaque A: cells. The effects of pH changes on phenotypic switching and sexual mating could involve a balance of host adaptation and sexual reproduction in C. albicans.

  20. Comparison of Repairing Effect Between Cobalt Chromium Alloy Porcelain Teeth and Zirconium Dioxide Porcelain Teeth%钴铬合金烤瓷牙和二氧化锆烤瓷牙修复效果对比

    Institute of Scientific and Technical Information of China (English)

    肖银蓉

    2015-01-01

    Objective To compare repairing effect of cobalt chromium alloy porcelain teeth and zirconium dioxide porcelain teeth. Methods To retrospective analyze 96 cases (172 tooth)clinical data of porcelain teeth prosthesis in our department from January 2010 to December 2013, the patients of zirconium dioxide porcelain teeth were 38 cases (70 tooth),which was zirconium dioxide porcelain teeth group,the patients of cobalt chromium alloy porcelain teeth were 58 cases(102 tooth), which was cobalt chromium alloy porcelain teeth group,the clinical result of two groups were compared. Results The effective rate 34 cases (94.73%)of zirco-nium dioxide porcelain teeth and effective rate 53 cases (91.37%)of cobalt chromium alloy porcelain teeth were compared, which was no difference (χ2=0.87,P>0.05). But after treatment of two groups,incidence of complications of cobalt chromium alloy porce-lain teeth group were higher than those of zirconium dioxide porcelain teeth group(χ2=3.95,P0.05)。但是两组患者治疗后,钴铬合金组并发症发生率高于二氧化锆组,差异有统计学意义(χ2=3.95,P<0.05)。结论二氧化锆烤瓷牙的疗效优于钴铬合金烤瓷牙,若患者经济条件允许,应该优先考虑二氧化锆烤瓷牙。

  1. Shear Bond Strength of Porcelain to a Base-Metal Compared to Zirconia Core

    Directory of Open Access Journals (Sweden)

    Abrisham SM

    2017-03-01

    Full Text Available Statement of Problem: Recent clinical results for Zirconia all-ceramic restorations have revealed that the fracture rate 6-15% of the Zirconia framework is so low and the core of Zirconia has high stability. However, chipping-off fractures of porcelain are the most common reason for failures of Zirconia in the fixed partial dentures. Objectives: The purpose of this study was to compare the shear bond strength (SBS of porcelain in the porcelain fused to metal and all-ceramic crowns with Zirconia core. Materials and Methods: Two groups were selected: porcelain fused to metal (PFM and porcelain fused to Zirconia (PFZ (n = 30.In the PFM group, a wax model (10 × 10 × 10mmwas used to cast metal base (Ni_Cr alloy. In the PFZ group, an acrylic cubic model (10 × 10 × 10mm was made as Zirconia model for scanning.15 cubic Zirconia samples were milled by CAD-CAM. The procedure of porcelain veneering was conducted by the conventional layering technique up to 2 mm thickness (2.5 × 2.5 × 2 mm. All specimens were stored in water for 48 hrs. Thermal cycling was conducted for 20000 cycles between 55°C and 5ºC alternatively for 30s.All samples were mounted in acrylic resin and the SBS test was performed, using a universal testing machine. The analysis of data was performed at a significance level of 0.05 using Kolmogorov-Smirnov and Mann-Whitney U-test. Results: Mean of SBS in PFM and PFZ was 24.57 and 20.88, respectively. The results of Mann-Whitney test showed that there was no statistically significant difference between the two groups of porcelain fused to metal and Zirconia in item shear bond strength (p = 0.455. Conclusions: There was no significant difference between the two groups of PFM and PFZ in the item SBS.

  2. Shear Bond Strength of Porcelain to a Base-Metal Compared to Zirconia Core.

    Science.gov (United States)

    Abrisham, S M; Fallah Tafti, A; Kheirkhah, S; Tavakkoli, M A

    2017-03-01

    Recent clinical results for Zirconia all-ceramic restorations have revealed that the fracture rate 6-15% of the Zirconia framework is so low and the core of Zirconia has high stability. However, chipping-off fractures of porcelain are the most common reason for failures of Zirconia in the fixed partial dentures. The purpose of this study was to compare the shear bond strength (SBS) of porcelain in the porcelain fused to metal and all-ceramic crowns with Zirconia core. Two groups were selected: porcelain fused to metal (PFM) and porcelain fused to Zirconia (PFZ) (n = 30).In the PFM group, a wax model (10 × 10 × 10mm)was used to cast metal base (Ni_Cr alloy). In the PFZ group, an acrylic cubic model (10 × 10 × 10mm) was made as Zirconia model for scanning.15 cubic Zirconia samples were milled by CAD-CAM. The procedure of porcelain veneering was conducted by the conventional layering technique up to 2 mm thickness (2.5 × 2.5 × 2 mm). All specimens were stored in water for 48 hrs. Thermal cycling was conducted for 20000 cycles between 55°C and 5ºC alternatively for 30s.All samples were mounted in acrylic resin and the SBS test was performed, using a universal testing machine. The analysis of data was performed at a significance level of 0.05 using Kolmogorov-Smirnov and Mann-Whitney U-test. Mean of SBS in PFM and PFZ was 24.57 and 20.88, respectively. The results of Mann-Whitney test showed that there was no statistically significant difference between the two groups of porcelain fused to metal and Zirconia in item shear bond strength (p = 0.455). There was no significant difference between the two groups of PFM and PFZ in the item SBS.

  3. Using Opaque Image Blur for Real-Time Depth-of-Field Rendering and Image-Based Motion Blur

    DEFF Research Database (Denmark)

    Kraus, Martin

    2013-01-01

    While depth of field is an important cinematographic means, its use in real-time computer graphics is still limited by the computational costs that are necessary to achieve a sufficient image quality. Specifically, color bleeding artifacts between objects at different depths are most effectively...... avoided by a decomposition into sub-images and the independent blurring of each sub-image. This decomposition, however, can result in rendering artifacts at silhouettes of objects. We propose a new blur filter that increases the opacity of all pixels to avoid these artifacts at the cost of physically less...... accurate but still plausible rendering results. The proposed filter is named "opaque image blur" and is based on a glowfilter that is applied to the alpha channel. We present a highly efficient GPU-based pyramid algorithm that implements this filter for depth-of-field rendering. Moreover, we demonstrate...

  4. Programmable two-photon quantum interference in $10^3$ channels in opaque scattering media

    CERN Document Server

    Wolterink, Tom A W; Ctistis, Georgios; Vos, Willem L; Boller, Klaus -J; Pinkse, Pepijn W H

    2015-01-01

    We investigate two-photon quantum interference in an opaque scattering medium that intrinsically supports $10^6$ transmission channels. By adaptive spatial phase-modulation of the incident wavefronts, the photons are directed at targeted speckle spots or output channels. From $10^3$ experimentally available coupled channels, we select two channels and enhance their transmission, to realize the equivalent of a fully programmable $2\\times2$ beam splitter. By sending pairs of single photons from a parametric down-conversion source through the opaque scattering medium, we observe two-photon quantum interference. The programmed beam splitter need not fulfill energy conservation over the two selected output channels and hence could be non-unitary. Consequently, we have the freedom to tune the quantum interference from bunching (Hong-Ou-Mandel-like) to antibunching. Our results establish opaque scattering media as a platform for high-dimensional quantum interference that is notably relevant for boson sampling and ph...

  5. Programmable two-photon quantum interference in 103 channels in opaque scattering media

    Science.gov (United States)

    Wolterink, Tom A. W.; Uppu, Ravitej; Ctistis, Georgios; Vos, Willem L.; Boller, Klaus-J.; Pinkse, Pepijn W. H.

    2016-05-01

    We investigate two-photon quantum interference in an opaque scattering medium that intrinsically supports a large number of transmission channels. By adaptive spatial phase modulation of the incident wave fronts, the photons are directed at targeted speckle spots or output channels. From 103 experimentally available coupled channels, we select two channels and enhance their transmission to realize the equivalent of a fully programmable 2 ×2 beam splitter. By sending pairs of single photons from a parametric down-conversion source through the opaque scattering medium, we observe two-photon quantum interference. The programed beam splitter need not fulfill energy conservation over the two selected output channels and hence could be nonunitary. Consequently, we have the freedom to tune the quantum interference from bunching (Hong-Ou-Mandel-like) to antibunching. Our results establish opaque scattering media as a platform for high-dimensional quantum interference that is notably relevant for boson sampling and physical-key-based authentication.

  6. Extraordinary blueshift of a photonic crystal nanocavity by reducing its mode volume with an opaque microtip

    Science.gov (United States)

    Grosjean, T.; El Eter, A.; Mivelle, M.; Vo, T.-Ph.; Belkhir, A.; Ecoffey, C.; Le Gac, G.; Nedeljkovic, D.; Rahmani, A.; Seassal, C.; Callard, S.; Baida, F.

    2012-07-01

    We demonstrate a method to reduce the mode volume of optical micro/nanocavities by positioning an opaque microtip in close proximity of the structures. This concept is used to blueshift the resonance of an active photonic crystal nanocavity by up to 16 nm. This tuning range is shown to be about 10 times larger than the redshift achieved with a bare dielectric microtip of the same size and shape. By imagining materials or multilayered devices with the ability to become transparent and opaque under external control, the blue and redshifts of the resonance would become possible with a single perturbing device.

  7. Shear bond strength of porcelain veneers rebonded to enamel.

    Science.gov (United States)

    St Germain, H A; St Germain, T H

    2015-01-01

    In this laboratory research, shear bond strength (SBS) and mode of failure of veneers rebonded to enamel in shear compression were determined. Three groups (A, B, and C; n=10 each) of mounted molar teeth were finished flat using wet 600-grit silicon carbide paper, and 30 leucite-reinforced porcelain veneers (5.0 × 0.75 mm) were air abraded on the internal surface with 50 μm aluminum oxide, etched with 9.5% hydrofluoric acid, and silanated. The control group (A) veneer specimens were bonded to enamel after etching with 37% phosphoric acid using bonding resin and a dual cure resin composite cement. Groups B and C were prepared similarly to group A with the exception that a release agent was placed before the veneer was positioned on the prepared enamel surface and the resin cement was subsequently light activated. The debonded veneers from groups B and C were placed in a casting burnout oven and heated to 454°C/850°F for 10 minutes to completely carbonize the resin cement and stay below the glass transition temperature (Tg) of the leucite-reinforced porcelain. The recovered veneers were then prepared for bonding. The previously bonded enamel surfaces in group B were air abraded using 50 μm aluminum oxide followed by 37% phosphoric acid etching, while group C enamel specimens were acid etched only. All specimens were thermocycled between 5°C and 55°C for 2000 cycles using a 30-second dwell time and stored in 37°C deionized water for 2 weeks. SBS was determined at a crosshead speed of 1.0 mm/min. SBS results in MPa for the groups were (A) = 20.6±5.1, (B) = 18.1±5.5, and (C) = 17.2±6.1. One-way analysis of variance indicated that there were no significant interactions (α=0.05), and Tukey-Kramer post hoc comparisons (α=0.05) detected no significant pairwise differences. An adhesive mode of failure at the enamel interface was observed to occur more often in the experimental groups (B = 40%, C = 50%). Rebonding the veneers produced SBS values that were not

  8. 76 FR 2708 - Porcelain-on-Steel Cooking Ware From Taiwan; Top-of-the-Stove Stainless Steel Cooking Ware From...

    Science.gov (United States)

    2011-01-14

    ... (Third Review)] Porcelain-on-Steel Cooking Ware From Taiwan; Top-of-the-Stove Stainless Steel Cooking... revocation of the antidumping duty order on imports of porcelain-on-steel cooking ware from Taiwan and the... antidumping duty order on imports of porcelain-on-steel cooking ware from Taiwan and the countervailing...

  9. Effects of different polishing techniques on the surface roughness of dental porcelains

    Directory of Open Access Journals (Sweden)

    Işil Sarikaya

    2010-02-01

    Full Text Available OBJECTIVE: The purpose of this study was to evaluate the effects of different polishing techniques on the surface roughness of dental porcelains. MATERIAL AND METHODS: Fifty-five cylindirical specimens (15x2 mm were prepared for each feldspathic (Vita VMK 95, Ceramco III and low-fusing dental porcelain (Matchmaker. Fifty-five specimens of machinable feldspathic porcelain blocks (Vitablocs Mark II, (12x14x18 mm were cut into 2-mm-thick slices (12x14 mm with low speed saw. The prepared specimens were divided into 11 groups (n=5 representing different polishing techniques including control ((C no surface treatment, glaze (G and other 9 groups that were finished and polished with polishing discs (Sof-Lex (Sl, two porcelain polishing kits (NTI (Pk, Dialite II (Di, a diamond polishing paste (Sparkle (Sp, a zirconium silicate based cleaning and polishing prophy paste (Zircate (Zr, an aluminum oxide polishing paste (Prisma Gloss (Pg, and combinations of them. The surface roughness of all groups was measured with a profilometer. The data were analyzed with a 2-way analysis of variance, and the mean values were compared by the Tukey Honestly Significant Difference test (a=0.05. RESULTS: For all porcelain material groups, the lowest Ra values were observed in Group Gl, Group Sl, Group Pk, and Group Di, which were not significantly different from each other (p>0.05.When comparing the 4 different porcelain materials, the machinable feldspathic porcelain block group (Mark II demonstrated statistically significantly less Ra values than the other porcelain materials tested (p<0.05. No significant difference was observed between the VMK 95 and Ceramco III porcelain groups (p=0.919, also these groups demonstrated the highest Ra values. CONCLUSION: Subjected to surface roughness, the surfaces obtained with polishing and/or cleaning-prophy paste materials used alone were rougher compared to the surfaces finished using Sof-lex, Dialite, and NTI polishing kit

  10. Evaluation of zirconia-porcelain interface using X-ray diffraction

    Institute of Scientific and Technical Information of China (English)

    Tariq F Alghazzawi; Gregg M Janowski

    2015-01-01

    The aim of this study was to determine if accelerated aging of porcelain veneering had an effect on the surface properties specific to a tetragonal-to-monoclinic transformation (TMT) of zirconia restorations. Thirty-six zirconia samples were milled and sintered to simulate core fabrication followed by exposure to various combinations of surface treatments including as-received (control), hydrofluoric acid (HF), application of liner plus firings, application of porcelain by manual layering and pressing with firing, plus accelerated aging. The quantity of transformed tetragonal to monoclinic phases was analyzed utilized an X-ray diffractometer and one-way analysis of variance was used to analyze data. The control samples as provided from the dental laboratory after milling and sintering process had no TMT (Xm 5 0). There was an effect on zirconia samples of HF application with TMT (Xm 5 0.8%) and liner plus HF application with TMT (Xm 5 8.7%). There was an effect of aging on zirconia samples (no veneering) with significant TMT (Xm 5 70.25%). Both manual and pressing techniques of porcelain applications reduced the TMT (manual, Xm 5 4.41%, pressing, Xm511.57%), although there was no statistical difference between them. It can be concluded that simulated applications of porcelain demonstrated the ability to protect zirconia from TMT after aging with no effect of a liner between different porcelain applications. The HF treatment also caused TMT.

  11. Sintering and dielectric properties of a technical porcelain prepared from economical natural raw materials

    Energy Technology Data Exchange (ETDEWEB)

    Kasrani, S.; Harabi, A.; Barama, S.-E.; Foughali, L.; Benhassine, M. T., E-mail: souad478@yahoo.fr, E-mail: harabi52@gmail.com, E-mail: sebarama@usa.com, E-mail: foughali_lazhar@yahoo.fr, E-mail: mtb25dz@gmail.com [Ceramics Lab. Mentouri University of Constantine (Algeria); Aldhayan, D.M., E-mail: aldhayan@ksu.edu.sa [Chemistry Department, Riyadh, King Saud University (Saudi Arabia)

    2016-10-15

    In this study, the production of a technical porcelain, for the ceramic dielectric applications by using economical natural raw materials, was investigated. The basic porcelain composition was selected consisting of 30 wt% kaolin, 45 wt% potash-feldspar and 25 wt% quartz. The obtained phases in the sintered samples were investigated by X-ray diffraction, Fourier transform infrared spectroscopy analysis, and scanning electron microscopy images. It has been confirmed by these techniques that the main crystalline phases were quartz and mullite. Dielectric measurements of technical porcelains have been carried out at 1 kHz from room temperature to 200 °C. The dielectric constant, loss factor, dielectric loss tangent, and resistivity of the porcelain sample sintered at 1160 °C were 22-25, 0.32-1.80, 0.006-0.07, and 0.2-9 x 10{sup 13} Ω.cm, respectively. The value of dielectric constant was significantly high when compared to that of conventional porcelains which did not exceed generally 9. (author)

  12. Shear bond strength of self-ligating orthodontic brackets on different types of porcelain crowns

    Directory of Open Access Journals (Sweden)

    Karamdeep Singh Ahluwalia

    2013-01-01

    Full Text Available Aim: The aim of this study is to compare shear bond strength (SBS and adhesive remnant index (ARI of self-ligating orthodontic brackets bonded to different porcelain crowns. Materials and Methods: Three groups of different types of porcelain crowns, each containing 12 crowns were fabricated by the same technician and allocated to one of the study groups as follows: Group I - IPS porcelain crowns (Ivoclar Vivadent AG, Schaan, Liechtenstein, Group II - Porcelain fused to zirconia crowns (Zirkonzahn GmbH, Gais, Italy, Noritake Co., Tokyo, Japan and Group III - Conventional porcelain fused to metal crowns (Ceramco3, Densply, PA, USA. The orthodontic brackets were bonded to these crowns using hydrofluoric acid (HFA + silane etching protocol. After bonding, the SBS of the brackets were tested with a universal testing machine under standard test conditions. Results: Statistical evaluation using analysis of variance showed a significant difference between the groups (P 0.05. Chi-square comparison revealed no significant difference in ARI scores between groups (P > 0.05. Conclusions: When HFA + silane etching protocol were used, IPS crowns showed the greatest SBS of orthodontic brackets. The ARI score was non-significant. Therefore, if there is a need to place crowns over teeth then these crowns can be used for restoration of teeth before orthodontic treatment.

  13. Effect of silica coating on the bond strength of milled pure titanium to dental porcelain.

    Science.gov (United States)

    Ye, Jiantao; Ye, Xiuhua; Chang, Shaohai; Liu, Lang; Zhang, Yiping; Lin, Shiyao

    2016-10-01

    The creation of a high bond strength between machined computer-manufactured pure titanium and porcelain remains problematic, and the effects of a silica coating on the bond strength of milled pure titanium bonded to dental porcelain require further investigation. The objective of this study was to evaluate the bond strength of machined pure titanium, with an intermediate coating of silica, to dental porcelain. In this work, 24 specimens of milled pure titanium were prepared and randomly divided into test and control groups, in which the test group was coated with silica using the sol-gel dipping technique. The metal-ceramic bond strength was evaluated, according to ISO 9693 standards, using the three-point bending test, and scanning electron microscopy and energy-dispersive spectroscopy were used to study the microstructure and elemental composition of the specimens. The bonding strength of the silica-coated group was significantly higher than that of the control group, and more residual porcelain on the metal surface could be observed in the silica-coated group. Therefore, the application of a silica intermediate coating produced using the sol-gel method could significantly improve the bond strength between machined pure titanium and porcelain.

  14. Evaluation of zirconia-porcelain interface using X-ray diffraction.

    Science.gov (United States)

    Alghazzawi, Tariq F; Janowski, Gregg M

    2015-09-14

    The aim of this study was to determine if accelerated aging of porcelain veneering had an effect on the surface properties specific to a tetragonal-to-monoclinic transformation (TMT) of zirconia restorations. Thirty-six zirconia samples were milled and sintered to simulate core fabrication followed by exposure to various combinations of surface treatments including as-received (control), hydrofluoric acid (HF), application of liner plus firings, application of porcelain by manual layering and pressing with firing, plus accelerated aging. The quantity of transformed tetragonal to monoclinic phases was analyzed utilized an X-ray diffractometer and one-way analysis of variance was used to analyze data. The control samples as provided from the dental laboratory after milling and sintering process had no TMT (Xm = 0). There was an effect on zirconia samples of HF application with TMT (Xm = 0.8%) and liner plus HF application with TMT (Xm = 8.7%). There was an effect of aging on zirconia samples (no veneering) with significant TMT (Xm = 70.25%). Both manual and pressing techniques of porcelain applications reduced the TMT (manual, Xm = 4.41%, pressing, Xm = 11.57%), although there was no statistical difference between them. It can be concluded that simulated applications of porcelain demonstrated the ability to protect zirconia from TMT after aging with no effect of a liner between different porcelain applications. The HF treatment also caused TMT.

  15. Comparison of Clinical Effects of Au-Pt Based and Ni-Cr Based Porcelain Crowns

    Institute of Scientific and Technical Information of China (English)

    Li-chun Wu; Ye Shi; Teng Ma

    2012-01-01

    Objective To compare the long-term clinical effects of two kinds of crowns and bridges made of porcelain fused to Au-Pt alloy and Ni-Cr alloy.Methods A total of 131 teeth (64 patients) were rehabilitated using porcelain-fused-to-metal crowns,among which 59 were rehabilitated with Au-Pt alloy metal ceramic crown and 72 with Ni-Cr alloy metal ceramic crown.The porcelain fracture,shade,marginal adaptation,gingival discoloration,and gingival status after finishing restoration and 36 months of follow-up were evaluated.Results After 36 months of restoration,porcelain fused to Au-Pt alloy crown showed better clinical effects than porcelain fused to Ni-Cr alloy crown in shade,marginal adaptation,gingival discoloration,as well as gingival status (all P<0.05).Conclusion The Au-Pt alloy ceramic crown is superior to Ni-Cr alloy ceramic crown in long-term clinical effects.

  16. Fuzzy cluster analysis of the provenance of ancient Yaozhou porcelain body

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The technique of neutron activation analysis (NAA) has been employed to measure the content of 29 kinds of elements in the sample of Yaozhou porcelain bodies. Then a fuzzy cluster analysis has been conducted to the NAA data and a diagram of the dynamic fuzzy cluster analysis has been achieved. The results indicate that the batch of ancient Yaozhou porcelain bodies, which were of different overglaze color and were produced by different kilns during a period of over 800 years from the Tang Dynasty (618-907 A.D.) to the Yuan Dynasty (1271-1368 A.D.), has shared a stable and concentrated raw material source. Provenances of porcelain bodies from different times, though having their specific independence, enjoy a close relationship and are not far from one another. Provenances of porcelain bodies made during the Tang Dynasty and the Five Dynasties (907-960 A.D.) are found to be closer to one another, while those of the Song (960-1279 A.D.) and the Jin Dynasty (1115-1234 A.D.) are comparatively concentrated in certain areas and are different from those of the Tang Dynasty. Both the tri-colored glazed pottery made in Yaozhou kilns during the Tang Dynasty and the Yaozhou porcelain bodies of the Tang period are from the same provenance.

  17. Sintering and dielectric properties of a technical porcelain prepared from economical natural raw materials

    Directory of Open Access Journals (Sweden)

    S. Kasrani

    Full Text Available Abstract In this study, the production of a technical porcelain, for the ceramic dielectric applications by using economical natural raw materials, was investigated. The basic porcelain composition was selected consisting of 30 wt% kaolin, 45 wt% potash-feldspar and 25 wt% quartz. The obtained phases in the sintered samples were investigated by X-ray diffraction, Fourier transform infrared spectroscopy analysis, and scanning electron microscopy images. It has been confirmed by these techniques that the main crystalline phases were quartz and mullite. Dielectric measurements of technical porcelains have been carried out at 1 kHz from room temperature to 200 °C. The dielectric constant, loss factor, dielectric loss tangent, and resistivity of the porcelain sample sintered at 1160 °C were 22-25, 0.32-1.80, 0.006-0.07, and 0.2-9 x 1013 Ω.cm, respectively. The value of dielectric constant was significantly high when compared to that of conventional porcelains which did not exceed generally 9.

  18. 76 FR 13602 - Porcelain-on-Steel Cooking Ware From the People's Republic of China: Continuation of Antidumping...

    Science.gov (United States)

    2011-03-14

    ... International Trade Administration Porcelain-on-Steel Cooking Ware From the People's Republic of China... revocation of the antidumping duty order on porcelain- on-steel cooking ware (``POS cookware'') from the... the ITC of the magnitude of the margins likely to prevail should the order be revoked. See...

  19. 76 FR 7534 - Porcelain-on-Steel Cooking Ware from the People's Republic of China: Final Results of the...

    Science.gov (United States)

    2011-02-10

    ... International Trade Administration Porcelain-on-Steel Cooking Ware from the People's Republic of China: Final... Commerce (``Department'') initiated a sunset review of the antidumping duty order on porcelain-on-steel... FR 60731 (October 1, 2010) (``Sunset Initiation''); see also Antidumping Duty Order;...

  20. Comparative evaluation of the shear bond strength of metal brackets bonded to porcelain using different porcelain surface treatments

    Directory of Open Access Journals (Sweden)

    Eslami Amirabadi GH

    2011-02-01

    Full Text Available "nBackground and Aims: The aim of this in vitro study was to compare shear bond strength of metal brackets bonded to dental porcelain on the basis of presence or absence of silane, type of acid [hydrofluoric acid (HF or phosphoric acid (H3PO4] and roughness of porcelain surface (glazed or deglazed within mouth-like environment."nMaterials and Methods: Eighty glazed ceramic disks were randomly divided into 8 groups of 10 disks: group 1 [HF+silane], group 2 [deglazed+HF+silane], group 3 [HF], group 4 [deglazed+HF], group 5 [H3PO4+silane], group 6 [deglazed+H3PO4+silane], group 7 [H3PO4], group 8 [deglazed+H3PO4]. Then the brackets were bonded and thermocycled. After that, shear bond strength test was done using the Zwick device and the type of bond failure was determined under stereomicroscope at 4X magnification. 3-way ANOVA and Kruskal-Wallis were used for statistical analyses."nResults: The shear bond strength for the test groups were as follows: group (1:13.05±7.7 MPa , group (2:25.16±10.66 MPa, group (3:6.7±5.86 MPa, group (4:15.39±8.97 MPa, group (5:12.76±7.91 MPa, group (6:13.57±7.85 MPa, group (7:0.54±0.67 MPa, group (8: 9.34±6.52 MPa. The type of bond failure in all groups was adhesive failure except for group 2. No significant difference in the interaction between (glazed or deglazed, (presence or absence of silane, and type of acid was found (P>0.05."nConclusion: Under the conditions of this study, the best clinical method was the use of 37% phosphoric acid and silane that resulted in the optimal clinical strength and adhesive bond failure.

  1. Porcelain Factory Worker With Asbestos-related Mesothelioma

    Directory of Open Access Journals (Sweden)

    Meng-Ting Tsou

    2009-10-01

    Full Text Available Malignant mesothelioma is a rare tumor among the general population, but for people exposed to asbestos, the lifetime risk is high. A 58-year old man presented with suffering from chest pain, upper back pain, shortness of breath, and coughing that had continued for several months. A chest X-ray revealed right-side pleural effusion; however, pleural biopsy from drainage treatment confirmed a diagnosis of malignant mesothelioma. According to his occupational and environmental history, the patient had worked continuously in a porcelain factory for 30 years. The specific characteristics of his work, making asbestos wallboards and gaskets, entailed working in high-temperature conditions with a high fine-particle content in the atmosphere. The high working temperature caused asbestos debris and dust to fall down regularly from the wallboards, however, it was not until recently that the patient had started to wear personal protection. Asbestos is a significant source of hazardous exposure in old buildings, and this case serves as a reminder of the importance of asbestos-related exposure history, which facilitated the correct diagnosis of pulmonary malignant mesothelioma. Asbestos-containing materials that are now banned or regulated are still present in older buildings and remain an exposure hazard; they continue to be a serious health concern in many countries.

  2. Investigation of 'chazi' (damaged-enamels) on Chenghua doucai Porcelains

    Institute of Scientific and Technical Information of China (English)

    DU Feng; SU BaoRu

    2009-01-01

    At the end of the 1950s, Sun Yingzhou considered that the 'chazi' (damaged colour) on Chenghua doucai imperial porcelain as a defect was originally produced in firing process during Chenghua period (1465-1487). Researchers in China have published his view. But any fragment with the 'chazi' has never been found in several tons of Chenghua imperial sherds excavated from Ming imperial kiln site in Jingdezhen. In China, few scholars have questioned the formation of 'chazi', and further investigated scientifically. The researchers at the Research Laboratory in the British Museum, employing unde-structive EDXRF, have analyzed the chemical composition of the 'chazi' (damaged colour) on a Chen-ghua doucai stem cup in the museum, and they have confirmed that the 'chazi' (damaged colour) was caused by the fire of the Jianfu palace in the Forbidden City in 1923. Based on their research, the au-thors studied the colour chemical principle of the 'chazi's' formation carefully. According to the ceramic technology principle, scientific reasoning for the 'chazi' was carried out. With the help of the history of Qing court, the brainteaser of the 'chazi' was totally uncovered, the misunderstanding for the 'chazi' has also been corrected. The research also suggests that employing modern science and technology is a direction to study Chinese ancient ceramic further.

  3. Thermal activation and radiation quenching characteristics and their application to the pre-dose dating of porcelain

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The pre-dose technique is important for thermoluminescence (TL) dating of porcelain. The principle of pre-dose dating is based on two characteristics: thermal activation and radiation quenching of the porcelain. Based on these principles, two measurement methods, "the activation method" and "the quenching method", respectively, have been developed for evaluation of the porcelain paleodose. The paleodose values obtained are the same for the ages in the range of 100―1000 a BP for porcelains measured by these two methods. But for dating at lower age limits (less than 100 a BP), the activation method is more accurate; conversely, at higher age limits (greater than 1000 a BP) the quenching method is more accurate. In addition, two specific calculating methods are described for a few porce-lains having anomalous activation and quenching characteristics that make these two methods invalid.

  4. Effect of vanadic anhydride and copper oxide on the development of hard porcelain composite and its antibacterial activity

    Directory of Open Access Journals (Sweden)

    Arpan Kool

    2014-09-01

    Full Text Available A mullite-reinforced porcelain composite with antibacterial properties has been developed using transition metal oxides by solid state sintering. The composite has been characterized in terms of mullite content, hardness, color and antibacterial properties. The physico-chemical properties of the porcelain were substantially increased in the presence of V2O5 and CuO. Well-crystallized needle shaped mullite of average length ∼ 3 μm was observed in the porcelain body at 1300 °C and 1500 °C after the addition of V2O5 and CuO. Vickers hardness of the composite increased 4.2 times for 2% V2O5 at 1500 °C. The porcelain composites showed satisfactory antibacterial activity on gram negative bacteria Escherichia coli with mortality rates of 45% and 22% for V2O5 and CuO doped porcelain respectively.

  5. Thermal activation and radiation quenching characteristics and their application to the pre-dose dating of porcelain

    Institute of Scientific and Technical Information of China (English)

    WANG WeiDa

    2009-01-01

    The pre-dose technique is important for thermoluminescence (TL) dating of porcelain. The principle of pre-dose dating is based on two characteristics: thermal activation and radiation quenching of the porcelain. Based on these principles, two measurement methods, "the activation method" and "the quenching method", respectively, have been developed for evaluation of the porcelain paleodose. The paleodose values obtained are the same for the ages in the range of 100--1000 a BP for porcelains measured by these two methods. But for dating at lower age limits (less than 100 a BP), the activation method is more accurate; conversely, at higher age limits (greater than 1000 a BP) the quenching method is more accurate. In addition, two specific calculating methods are described for a few porce-lains having anomalous activation and quenching characteristics that make these two methods invalid.

  6. The effect of melt infiltration of borosilicate glass on biaxial flexural strength of porcelain-veneered zirconia

    Science.gov (United States)

    Joo, Kyu Ji; Song, Kyung Woo; Jung, Jong Hyun; Ahn, Hyo Jin; Park, Il Song; Lee, Min Ho; Bae, Tae Sung

    2011-08-01

    To evaluate the effect of melt infiltration on the biaxial flexural strength of porcelain-bonded zirconia, borosilicate glasses were used in this study. Presintered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) blocks were milled and used for disc specimens. Prior to veneering of porcelain, the infiltration of borosilicate glass on zirconia was performed at 1,100 °C for 1 h. After a biaxial flexural test with the crosshead speed of 0.1 mm/min, fractured surfaces and interfaces between zirconia and veneer porcelain were observed with a Scanning Electron Microscope (SEM). The fracture strength of sintered zirconia and veneer porcelain was significantly increased by the melt infiltration of borosilicate glass (P porcelain increased slightly. The sintered zirconia group showed a smooth fracture surface containing many pores, but the glass-infiltrated zirconia group showed a rough fracture surface.

  7. Infants' Reasoning about Opaque and Transparent Occluders in an Individuation Task.

    Science.gov (United States)

    Wilcox, Teresa; Chapa, Catherine

    2002-01-01

    This study examined whether 9.5-month-olds could use featural information to individuate objects. Results suggest that infants categorize events involving opaque and transparent occluders as the same kind of situation and that infants are more likely to give evidence of individuation when they need to reason about one kind of event than when they…

  8. Structure of the transcriptional network controlling white-opaque switching in Candida albicans.

    Science.gov (United States)

    Hernday, Aaron D; Lohse, Matthew B; Fordyce, Polly M; Nobile, Clarissa J; DeRisi, Joseph L; Johnson, Alexander D

    2013-10-01

    The human fungal pathogen Candida albicans can switch between two phenotypic cell types, termed 'white' and 'opaque'. Both cell types are heritable for many generations, and the switch between the two types occurs epigenetically, that is, without a change in the primary DNA sequence of the genome. Previous work identified six key transcriptional regulators important for white-opaque switching: Wor1, Wor2, Wor3, Czf1, Efg1, and Ahr1. In this work, we describe the structure of the transcriptional network that specifies the white and opaque cell types and governs the ability to switch between them. In particular, we use a combination of genome-wide chromatin immunoprecipitation, gene expression profiling, and microfluidics-based DNA binding experiments to determine the direct and indirect regulatory interactions that form the switch network. The six regulators are arranged together in a complex, interlocking network with many seemingly redundant and overlapping connections. We propose that the structure (or topology) of this network is responsible for the epigenetic maintenance of the white and opaque states, the switching between them, and the specialized properties of each state.

  9. 78 FR 71643 - Certain Opaque Polymers; Notice of Commission Decision Amending the Complaint and Notice of...

    Science.gov (United States)

    2013-11-29

    ... From the Federal Register Online via the Government Publishing Office ] INTERNATIONAL TRADE COMMISSION Certain Opaque Polymers; Notice of Commission Decision Amending the Complaint and Notice of Investigation AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given...

  10. Diversity of yeasts involved in the fermentation of tchoukoutou, an opaque sorghum beer from Benin

    NARCIS (Netherlands)

    Kayode, A.P.P.; Vieira-Dalode, G.; Linnemann, A.R.; Kotchoni, S.O.; Hounhouigan, A.J.D.; Boekel, van M.A.J.S.; Nout, M.J.R.

    2011-01-01

    Opaque sorghum beers are traditional alcoholic beverages in several African countries. Known as tchoukoutou in Benin, the beer is often obtained from an uncontrolled fermentation. It is consumed in an actively fermenting state and has a sour taste. The present study characterized and identified the

  11. Minimally invasive porcelain veneers: indications for a conservative esthetic dentistry treatment modality.

    Science.gov (United States)

    Strassler, Howard E

    2007-11-01

    Patients have many restorative options for changing the appearance of their teeth. The most conservative restorative treatments for changing the appearance of teeth include tooth bleaching, direct composite resin veneers, and porcelain veneers. Patients seeking esthetic treatment should undergo a comprehensive clinical examination that includes an esthetic evaluation. When selecting a conservative treatment modality, the use of minimally invasive or no-preparation porcelain veneers should be considered. As with any treatment decision, the indications and contraindications must be considered before a definitive treatment plan is made. Long-term research has demonstrated a 94% survival rate for minimally invasive porcelain veneers. While conservation of tooth structure is important, so is selecting the right treatment modality for each patient based on clinical findings.

  12. Surface roughness of a novel dental porcelain following different polishing procedures.

    Science.gov (United States)

    Wang, Fu; Chen, Ji-Hua; Wang, Hui

    2009-01-01

    This study aimed to compare the surface roughness of a novel dental porcelain following different polishing procedures. One hundred twenty Imagine Reflex porcelain disks were prepared and randomly assigned into six groups according to different treatments: Group 1: CeraMaster polishing system (CP); Group 2: CP + diamond polishing paste (DP); Group 3: Sof-Lex polishing system (SS); Group 4: SS + DP; Group 5: SiC paper polishing; Group 6: reglazing (control). After the respective treatments, surface roughness values were measured using a profilometer. Qualitative analysis was performed using scanning electron microscopy. Results demonstrated that a combination of the CeraMaster polishing system and a diamond polishing paste could produce similar superficial smoothness to that of the reglazed surface of the tested porcelain.

  13. PIXE study on Chinese underglaze-red porcelain made in Yuan Dynasty

    Institute of Scientific and Technical Information of China (English)

    CHENG Huan-Sheng; ZHANG Zheng-Quan; LIN Er-Kang; HUANG Yun-Peng

    2004-01-01

    In China, the firing and glazed red techniques of producing underglaze-red porcelain began early in the Yuan Dynasty (AD1206~ 1368). This paper reports the results of the PIXE analysis of ancient Chinese underglaze-red porcelain produced at Kuan kiln (Jingdezhen, Jiangxi Province) in the Yuan Dynasty. In this work the elemental composition analysis of the obtained samples was carried out using the PIXE facility of a 3 MeV tandem accelerator at Fudan University. The major; minor and trace elements of the clay body, white and red glazes were determined,and details of the results are presented. The obtained data can be used for identification of precious Chinese Yuan underglaze-red porcelain.

  14. Laser photoacoustic technique for ultrasonic surface acoustic wave velocity evaluation on porcelain

    Science.gov (United States)

    Qian, K.; Tu, S. J.; Gao, L.; Xu, J.; Li, S. D.; Yu, W. C.; Liao, H. H.

    2016-10-01

    A laser photoacoustic technique has been developed to evaluate the surface acoustic wave (SAW) velocity of porcelain. A Q-switched Nd:YAG laser at 1064 nm was focused by a cylindrical lens to initiate broadband SAW impulses, which were detected by an optical fiber interferometer with high spatial resolution. Multiple near-field surface acoustic waves were observed on the sample surface at various locations along the axis perpendicular to the laser line source as the detector moved away from the source in the same increments. The frequency spectrum and dispersion curves were obtained by operating on the recorded waveforms with cross-correlation and FFT. The SAW phase velocities of the porcelain of the same source are similar while they are different from those of different sources. The marked differences of Rayleigh phase velocities in our experiment suggest that this technique has the potential for porcelain identification.

  15. Study of the adherence between polymer-modified mortars and porcelain stoneware tiles

    Directory of Open Access Journals (Sweden)

    Alessandra Etuko Feuzicana de Souza Almeida

    2005-09-01

    Full Text Available Despite the excellent characteristics of porcelain tiles, their application on building facades requires special attention, since this material differs from conventional ceramics and because facades are exposed to weathering that can damage ceramic revetments. The combination of polymer and silica fume to produce mortars results in excellent properties, which are ideal for repairs and revetments requiring high performance. Such improvements justify its study for the installation of porcelain tiles. This article presents bond strength results for mortars containing different amounts of polymer and silica indicating the applicability of these mortars as a construction material. To complement this study, the interface between the porcelain and the mortars was analyzed by scanning electron microscopy (SEM.

  16. Simulated fatigue resistance of composite resin versus porcelain CAD/CAM overlay restorations on endodontically treated molars.

    Science.gov (United States)

    Magne, Pascal; Knezevic, Alena

    2009-02-01

    To assess the influence of material selection (porcelain versus composite resin) for overlay-type restoration of endodontically treated molars and its effect on the in vitro fatigue resistance and failure mode. A standardized tooth preparation was applied to 30 extracted molars, including root canal treatment, 3-mm coverage of all cusps, a mesial box 1.5 mm below the cementoenamel junction (CEJ), a distal box in enamel, a glass-ionomer base, and immediately sealed dentin. Using the Cerec machine (Sirona), all teeth were restored with an overlay of standardized thickness and occlusal anatomy. Fifteen restorations were milled in the ceramic Vita MKII block (Vident) and the other 15 using the composite resin Paradigm MZ100 block (3M ESPE). The intaglio surfaces of the ceramic restorations were etched and silanated. The intaglio surfaces of the composite resin overlays were airborne-particle abraded and silanated. Preparations were airborne-particle abraded and etched before restoration insertion. All restorations were adhesively luted with an adhesive resin (Optibond FL, Kerr) and a light-curing composite resin (Filtek Z100, 3M ESPE). Cyclic isometric chewing (5 Hz) was simulated, starting with a load of 200 N (5,000 cycles), followed by stages of 400, 600, 800, 1,000, 1,200, and 1,400 N at a maximum of 30,000 cycles each. Samples were loaded until fracture or to a maximum of 185,000 cycles. MKII overlays fractured at a mean load of 1,147 N, and none of them withstood all 185,000 loading cycles (survival = 0%); with MZ100, the survival rate was 73%. With MKII, 40% of the fractures ended below the CEJ; with MZ100, only 25% did. Composite resin MZ100 increased the fatigue resistance of overlay-type restorations in endodontically treated molars when compared to porcelain MKII. The efficiency of the bond strategy (immediate dentin sealing) was demonstrated by the absence of adhesive failures.

  17. Comparison of porcelain bond strength of different metal frameworks prepared by using conventional and recently introduced fabrication methods.

    Science.gov (United States)

    Kaleli, Necati; Saraç, Duygu

    2017-07-01

    Most studies evaluating dental laser sintering systems have focused on the marginal accuracy of the restorations. However, the bond strength at the metal-ceramic interface is another important factor that affects the survival of restorations, and currently, few studies focus on this aspect. The purpose of this in vitro study was to compare the porcelain bond strength of cobalt-chromium (Co-Cr) metal frameworks prepared by using the conventional lost-wax technique, milling, direct metal laser sintering (DMLS), and laser cusing, a direct process powder-bed system. A total of 96 metal frameworks (n=24 in each group) were prepared by using conventional lost-wax (group C), milling (group M), DMLS (group LS), and direct process powder-bed (group LC) methods according to International Organization for Standardization standard ISO 9693-1. After porcelain application, a 3-point bend test was applied to each specimen by using a universal testing machine. Data were statistically analyzed using 1-way ANOVA and Tukey honest significant difference tests (α=.05). Failure types at the metal-ceramic interfaces were examined using stereomicroscopy. Additionally, 1 specimen from each group was prepared for scanning electron microscopy analysis to evaluate the surface topography of metal frameworks. The mean bond strength was 38.08 ±3.82 MPa for group C, 39.29 ±3.51 MPa for group M, 40.73 ±3.58 MPa for group LS, and 41.24 ±3.75 MPa for group LC. Statistically significant differences were observed among the 4 groups (P=.016). All groups, except for LS, exhibited adhesive and mixed type bond failure. Both of the laser sintering methods were found to be successful in terms of metal-ceramic bond strength. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Adhesion determination of dental porcelain to zirconia using the Schwickerath test: strength vs. fracture energy approach.

    Science.gov (United States)

    Kosyfaki, P; Swain, M V

    2014-11-01

    Two approaches to measure the fracture energy to delaminate four different porcelains from zirconia substrates are compared using Schwickerath adhesion strength test specimens. In all instances it was possible to stably extend the crack along or adjacent to the porcelain-zirconia interface. The fracture energy expended to delaminate the porcelain was found by determining the work of fracture upon loading to 12 N and then unloading. Additional tests were undertaken on specimens notched along the interface, which enabled the compliance of the cracked Schwickerath specimens to be calibrated. The strain energy and deflection of the Schwickerath specimen as a function of crack length were derived. On this basis a simple expression was determined for the strain energy release rate or interfacial fracture toughness from the minima in the force-displacement curves. Consequently two measures of the adhesion energy were determined, the work of fracture and the strain energy release rate. It was found that the ranking for the four porcelains bonded to zirconia differed depending upon the approach. The work of fracture was substantially different from the strain energy release rate for three of the porcelain-zirconia systems and appears to be directly related to the residual stresses present in the bonded structures. The relative merits of the strain energy release rate, work of fracture vs. the stress to initiate cracking in the case of the Schwickerath adhesion test, are discussed. The advantage of this test is that it enables three estimates of the adhesion for porcelain veneers bonded to zirconia. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. Porcelain laminate veneer conditioning for orthodontic bonding: SEM-EDX analysis.

    Science.gov (United States)

    Aksakalli, Sertac; Ileri, Zehra; Yavuz, Tevfik; Malkoc, Meral Arslan; Ozturk, Nilgun

    2015-09-01

    The purpose of this in vitro study was to evaluate and compare the effects of different surface treatments and laser irradiation on the bond strength of brackets bonded to porcelain laminate veneer. Porcelain laminate veneer specimens were embedded in the centers of acrylic resin blocks. Thirty-nine teeth were used for shear bond strength testing and the remaining three (one tooth for each group) were used for evaluation of the debonded bracket interface. Specimens were randomly divided into three groups, each containing 13 specimens. The details of the groups are as follows: Group SB, sandblasting with alumina particles (50 μm); Group HFA, 9.6 % hydrofluoric acid etching; Group ER, erbium-doped yttrium-aluminum-garnet (Er: YAG) irradiation (from 1 mm distance, 2 W, 10 Hz for 10 s). After conditioning, the upper central brackets were bonded to the porcelain surfaces. Porcelain laminate veneers were examined under stereomicroscope for adhesive remnant index and surface damage after debonding. The highest shear bond strength values were obtained with Group HFA (10.8 ± 3.8 MPa) and Group ER (9.3 ± 1.5 MPa), whereas Group SB revealed the lowest values. Scanning electron microscopy energy-dispersive X-ray (SEM-EDX) analysis revealed that the silicon level in the porcelain decreased after debonding in all groups. The sandblasting method did not demonstrate any ideal bond strength values; however, the 9.6 % hydrofluoric acid etching and Er: YAG laser did. There were no significant differences among all groups in terms of laminate surface damages. The Er: YAG laser therefore can be selected for ideal bond strength and minimal damage to porcelain laminates.

  20. On the interfacial fracture of porcelain/zirconia and graded zirconia dental structures.

    Science.gov (United States)

    Chai, Herzl; Lee, James J-W; Mieleszko, Adam J; Chu, Stephen J; Zhang, Yu

    2014-08-01

    Porcelain fused to zirconia (PFZ) restorations are widely used in prosthetic dentistry. However, their susceptibility to fracture remains a practical problem. The failure of PFZ prostheses often involves crack initiation and growth in the porcelain, which may be followed by fracture along the porcelain/zirconia (P/Z) interface. In this work, we characterized the process of fracture in two PFZ systems, as well as a newly developed graded glass-zirconia structure with emphases placed on resistance to interfacial cracking. Thin porcelain layers were fused onto Y-TZP plates with or without the presence of a glass binder. The specimens were loaded in a four-point-bending fixture with the thin porcelain veneer in tension, simulating the lower portion of the connectors and marginal areas of a fixed dental prosthesis (FDP) during occlusal loading. The evolution of damage was observed by a video camera. The fracture was characterized by unstable growth of cracks perpendicular to the P/Z interface (channel cracks) in the porcelain layer, which was followed by stable cracking along the P/Z interface. The interfacial fracture energy GC was determined by a finite-element analysis taking into account stress-shielding effects due to the presence of adjacent channel cracks. The resulting GC was considerably less than commonly reported values for similar systems. Fracture in the graded Y-TZP samples occurred via a single channel crack at a much greater stress than for PFZ. No delamination between the residual glass layer and graded zirconia occurred in any of the tests. Combined with its enhanced resistance to edge chipping and good esthetic quality, graded Y-TZP emerges as a viable material concept for dental restorations.

  1. A pilot study comparing opaque, weighted bottles with conventional, clear bottles for infant feeding.

    Science.gov (United States)

    Ventura, Alison K; Pollack Golen, Rebecca

    2015-02-01

    It is hypothesized that the visual and weight cues afforded by bottle-feeding may lead mothers to overfeed in response to the amount of liquid in the bottle. The aim of the present pilot study was to test this hypothesis by comparing mothers' sensitivity and responsiveness to infant cues and infants' intakes when mothers use opaque, weighted bottles (that remove visual and weight cues) compared to conventional, clear bottles to feed their infants. We also tested the hypothesis that mothers' pressuring feeding style would moderate the effect of bottle type. Formula-feeding dyads (N = 25) visited our laboratory on two separate days. Mothers fed their infants from a clear bottle one day and an opaque, weighted bottle on the other; bottle-order was counterbalanced across the two days. Infant intake was assessed by weighing each bottle before and after the feeding. Maternal sensitivity and responsiveness to infant cues was objectively assessed using the Nursing Child Assessment Feeding Scale. Mothers were significantly more responsive to infant cues when they used opaque compared to clear bottles (p = .04). There was also a trend for infants to consume significantly less formula when fed from opaque compared to clear bottles (p = .08). Mothers' pressuring feeding style moderated the effect of bottle type on maternal responsiveness to infant cues (p = .02) and infant intake (p = .03). Specifically, mothers who reported higher levels of pressuring feeding were significantly more responsive to their infants' cues (p = .02) and fed their infants significantly less formula when using opaque versus clear bottles (p = .01); no differences were seen for mothers who reported lower levels of pressuring feeding. This study highlights a simple, yet effective intervention for improving the bottle-feeding practices of mothers who have pressuring feeding styles.

  2. Effect of an Opaque Reflecting Layer on the Thermal Behavior of a Thermal Barrier Coating

    Science.gov (United States)

    Spuckler, Charles M.

    2007-01-01

    A parametric study using a two-flux approximation of the radiative transfer equation was performed to examine the effects of an opaque reflective layer on the thermal behavior of a typical semitransparent thermal barrier coating on an opaque substrate. Some ceramic materials are semitransparent in the wavelength ranges where thermal radiation is important. Even with an opaque layer on each side of the semitransparent thermal barrier coating, scattering and absorption can have an effect on the heat transfer. In this work, a thermal barrier coating that is semitransparent up to a wavelength of 5 micrometers is considered. Above 5 micrometers wavelength, the thermal barrier coating is opaque. The absorption and scattering coefficient of the thermal barrier was varied. The thermal behavior of the thermal barrier coating with an opaque reflective layer is compared to a thermal barrier coating without the reflective layer. For a thicker thermal barrier coating with lower convective loading, which would be typical of a combustor liner, a reflective layer can significantly decrease the temperature in the thermal barrier coating and substrate if the scattering is weak or moderate and for strong scattering if the absorption is large. The layer without the reflective coating can be about as effective as the layer with the reflective coating if the absorption is small and the scattering strong. For low absorption, some temperatures in the thermal barrier coating system can be slightly higher with the reflective layer. For a thin thermal barrier coating with high convective loading, which would be typical of a blade or vane that sees the hot sections of the combustor, the reflective layer is not as effective. The reflective layer reduces the surface temperature of the reflective layer for all conditions considered. For weak and moderate scattering, the temperature of the TBC-substrate interface is reduced but for strong scattering, the temperature of the substrate is increased

  3. Convergent Regulation of Candida albicans Aft2 and Czf1 in Invasive and Opaque Filamentation.

    Science.gov (United States)

    Xu, Ning; Dong, Yi-Jie; Yu, Qi-Lin; Zhang, Bing; Zhang, Meng; Jia, Chang; Chen, Yu-Lu; Zhang, Biao; Xing, Lai-Jun; Li, Ming-Chun

    2015-09-01

    Candida albicans is the most common fungal pathogen of mucosal infections and invasive diseases in immuno-compromised humans. The abilities of yeast-hyphal growth and white-opaque switching affect C. albicans physiology and virulence. Here, we showed that C. albicans Aft2 regulator was required for embedded filamentous growth and opaque cell-type formation. Under low-temperature matrix embedded conditions, Aft2 functioned downstream of Czf1-mediated pathway and was required for invasive filamentation. Moreover, deletion of AFT2 significantly reduced opaque cell-type formation under N-acetylglucosamine (GlcNAc) inducing conditions. Ectopic expression of CZF1 slightly increased the white-opaque switching frequency in the aft2Δ/Δ mutant, but did not completely restore to wild-type levels, suggesting that Czf1 at least partially bypassed the essential requirement for Aft2 in response to opaque-inducing cues. In addition, multiple environmental cues altered AFT2 mRNA and protein levels, such as low temperature, physical environment and GlcNAc. Although the absence of Czf1 or Efg1 also increased the expression level of AFT2 gene, deletion of CZF1 remarkably reduced the stability of Aft2 protein. Furthermore, C. albicans Aft2 physically interacted with Czf1 under all tested conditions, whereas the interaction between Aft2 and Efg1 was barely detectable under embedded conditions, supporting the hypothesis that Aft2, together with Czf1, contributed to activate filamentous growth by antagonizing Efg1-mediated repression under matrix-embedded conditions.

  4. Bio-beneficiation of kaolin and feldspar and its effect on fired characteristics of triaxial porcelain

    Indian Academy of Sciences (India)

    Anandita Roy; Samarendra K Singh; P C Banerjee; Kausik Dana; Swapan Kumar Das

    2010-06-01

    Presence of iron compounds as impurities in kaolin and feldspar, impart reddish colour to ceramic products manufactured using these minerals. The quality of kaolin and feldspar was enriched mainly through iron removal by biological methods. Bacteria isolated from kaolin of Indian origin were used for bioleaching. Biotreatment of kaolin and feldspar using indigenous bacteria not only lowered the iron content of the minerals but also improved their whiteness. The porcelain prepared with these biobeneficiated minerals was compared to that prepared with non-beneficiated one. Physico-mechanical properties of porcelain were distinctly improved by using biobeneficiated kaolin and feldspar, without affecting the individual mineralogical compositions of kaolin and feldspar.

  5. Titania doped triaxial porcelain: Enhancement of strength by controlled heat treatment

    Indian Academy of Sciences (India)

    Sunipa Bhattacharyya; Swapan Kumar Das; Kausik Dana; Nirendra Krishna Mitra

    2007-06-01

    Titania doped vitrified triaxial porcelain samples were subjected to controlled heat treatment at different temperatures of 600, 800 and 1000°C with a specific heating schedule. The results revealed that flexural strength of 800°C heat treated sample was significantly enhanced to 60 MPa from its original value of 40 MPa. XRD pattern revealed the formation of mullite in the system both before and after heat treatment and the differences in their growth was ascertained through SEM analysis. The present heat treatment process may be useful to produce high strength porcelain body from a common triaxial system.

  6. Influence of a prophylaxis paste on surface roughness of different composites, porcelain, enamel and dentin surfaces

    OpenAIRE

    2012-01-01

    Objective: To investigate the effect of a prophylaxis paste on surface roughness of different composites, enamel, dentin and porcelain surfaces. Methods: Three different composites (FiltekZ250/Group1, Filtek Supreme XT/Group2, Premise/Group3), enamel/Group4, dentin/Group5 and porcelain/Group6 samples were used in this study. All specimens were prepared flat by SiC discs and polished with a diamond polishing paste. The surface roughness measurements were determined with a profilometer after po...

  7. Comparison of acidulated phosphate fluoride gel and hydrofluoric acid etchants for porcelain-composite repair.

    Science.gov (United States)

    Tylka, D F; Stewart, G P

    1994-08-01

    Hydrofluoric acid etches porcelain to produce a porous surface visible under scanning electron microscopy when compared to an acidulated phosphate fluoride gel. Some investigators have suggested the greater porosity of the hydrofluoric acid etch produces a greater composite-to-porcelain bond. This investigation tested that assumption with two common fluoride etchants. The etched surfaces were first viewed under scanning electron microscopy to ensure that a characteristic etch was achieved. Both etchants yielded bond strengths that produced cohesive failure of all samples. This suggested that the intraoral use of hydrofluoric acid is no more effective than the less dangerous acidulated phosphate fluoride gel.

  8. Effect of thermocycling on the flexural strength of porcelain laminate veneers

    Directory of Open Access Journals (Sweden)

    Subramanian Deepa

    2008-01-01

    Full Text Available Aim: The aim of this study was to examine the impact of thermocycling on the flexural strength and development of surface flaws on the glazed surface of porcelain laminate veneer restorations with and without resin luting cement. Materials and Methods: 80 Vitadur alpha dentin porcelain discs (10 mm diameter, 0.9 mm thickness were glazed on one side and divided into two groups: A (porcelain laminate veneer only without resin luting cement and B (porcelain laminate veneer luted with resin cement, each containing 40 discs. The discs in groups A and B were then thermocycled at different temperatures and were subjected to SEM analysis to evaluate the effect of thermocycling on crack propagation. Mean flexural strength was determined by using the ball-on-ring test. Student′s t -test was used to find out the difference between strength values of the thermocycled porcelain discs and discs luted with resin cement. Results: SEM analysis revealed crack propagation in the subgroups subjected to extremes of temperature, i.e., 4 ± 1°C, 37 ± 1°C and 4 ± 1°C, 65 ± 1°C in the porcelain laminate veneers luted with resin cement. Flexural strength analysis revealed superior flexural strength for porcelain laminate veneers: 88.58 ± 6.94 Mpa when compared to porcelain laminate veneers luted with resin cement: 8.42 ± 2.60 MPa. Results were tabulated and statistically analyzed using Student′s t -test. Conclusion: Laminate veneer specimens exhibited greater flexural strength than those which were luted with resin cements. Laminate veneer specimens luted with resin cement and subjected to extremes of temperature, 4 ± 1°C and 37 ± 1°C and 4 ± 1°C and 65 ± 1°C, showed a marked decrease in flexural strength. After thermocycling at extremes of temperature, laminate veneer specimens luted with resin cement showed crack propagation. Fit of laminate veneers cannot / should not be compensated by the thickness of luting agent.

  9. The effect of zirconium coating on bonding strength of porcelain to titanium

    Institute of Scientific and Technical Information of China (English)

    Duan Zhenzhen; Sun Daqian; Qiu Xiaoming; Gu Xiaoyan; Sun Dexin

    2008-01-01

    The Zr coating was deposited on titanium surface using the magnetron sputtering technique. Effects of Zr coating on microstracture and mechanical properties of porcelain fired to titanium have been investigated. The results show that interdiffusion of elements occurs during porcelain firing, and the Zr coating can effectively protect titanium surface from excess oxidation. The strength of bond zone with Zr coating deposited for 1 hour reaches 29.7 Mpa, which has increased by 26.4% as compared with that of bond zone without coating (23.5 Mpa).

  10. The effect of fluxing agent MnO2 on alumina silicate porcelain insulator properties

    Science.gov (United States)

    Dudi, Dharmender; Shekhawat, M. S.; Singh, G. P.

    2016-05-01

    Higher strength electrical porcelain is a requirement for industry. This will be achieved by a specific composition of raw materials, which is consisted of clays and feldspars. High mechanical resistance, low porosity and water absorption are among their important properties. By decreasing the silica and increasing the alumina provides a higher mechanical strength in porcelain but on the other hand increases the body's baking temperature. Therefore adding MnO2 in different percentage is a suitable and practical solution to improve strength without increasing sinter temperature. Results have shown that addition of 1% MnO2 in body enhances mechanical strength of the body.

  11. An optically stimulated luminescence study of porcelain related to radiation dosimetry

    DEFF Research Database (Denmark)

    Poolton, N.R.J.; Bøtter-Jensen, L.; Jungner, H.

    1995-01-01

    This article describes the essential features regarding the photo-stimulated luminescence of porcelain: both the main ceramic and glazing materials are studied. In each case, radiation dose dependent signals are observed, superimposed on dose independent luminescence transitions that are both...... Stokes and anti-Stokes shifted in energy. Glazing is shown in some cases to be considerably more sensitive as a radiation dosemeter than the main porcelain ceramic. By comparison with the properties of artifical phosphors, the principal luminescent matrix is identified as being Al2O3...

  12. Transcatheter aortic valve implantation in patients with "porcelain" aorta (from a Multicenter Real World Registry).

    Science.gov (United States)

    Zahn, Ralf; Schiele, Rudolf; Gerckens, Ulrich; Linke, Axel; Sievert, Horst; Kahlert, Philipp; Hambrecht, Rainer; Sack, Stefan; Abdel-Wahab, Mohamed; Hoffmann, Ellen; Senges, Jochen

    2013-02-15

    The presence of severe atherosclerosis of the ascending aorta, and its extreme form the "porcelain" aorta, is associated with a worse clinical outcome in patients undergoing surgical aortic valve replacement. Percutaneous transcatheter aortic valve implantation (TAVI) for severe symptomatic aortic stenosis can overcome this problem: 1,374 TAVI procedures were performed at 27 hospitals in 147 patients (10.7%) with and 1,227 (89.3%) without a porcelain aorta. The mean reported prevalence of a porcelain aorta at the hospitals was 7.8% ± 14.8% (range 0% to 70%). Diabetes mellitus (46.3% vs 33.2%, p = 0.00018), chronic obstructive pulmonary disease (43.5% vs 22.2%, p <0.0001), and peripheral arterial obstructive disease (34.7% vs 20.0%, p <0.0001) were more prevalent in patients with a porcelain aorta. In patients with a porcelain aorta, coronary ischemia occurred more often (2.0% vs 0.1%, p <0.0001), with a tendency toward a greater stroke rate (5.5% vs 2.8%, p = 0.08), greater in-hospital death rate (10.9% vs 8.1%, p = 0.24), and greater death or stroke rate (14.4% vs 10.2%, p = 0.12). On multivariate analysis, the presence of a porcelain aorta was not associated with in-hospital death (odds ratio 1.36, 95% confidence interval 0.72 to 2.55, p = 0.3441) nor in-hospital death or stroke (odds ratio 1.50, 95% confidence interval 0.81 to 2.47, p = 0.2207). In conclusion, in this real-world TAVI registry, a "porcelain" aorta was diagnosed in almost every tenth patient. Although differences were found in its frequency among the participating hospitals, the presence of a porcelain aorta was not associated with in-hospital death or stroke.

  13. Tooth preparation and fabrication of porcelain veneers using a double-layer technique.

    Science.gov (United States)

    Chpindel, P; Cristou, M

    1994-09-01

    This article discusses proper tooth preparation when using the double-layered porcelain technique for constructing porcelain veneers designed to produce strength and translucency. Indications for this technique include color correction, restoration of lost tooth structure or improper tooth size, and overall smile design. A new indication--misalignment--has been added. The objective of this article is to review tooth preparation and double-layered laboratory techniques using hydrothermal ceramics in combination. Four cases are used to illustrate the procedure, concentrating on the correction of misaligned teeth.

  14. Significance of structure–property relationship in alumina based porcelain insulators to achieve quality

    Indian Academy of Sciences (India)

    Parvati Ramaswamy; S Vynatheya; S Seetharamu

    2005-12-01

    The catastrophic failures of porcelain insulators in power lines can be minimized by understanding the structure–property relationship that governs the performance. A study addressing the materials aspects has been conducted on alumina based porcelain insulators used in 25 kV railway traction lines. This article asserts the controls exercised by chemical composition, crystalline structural phases and microstructure on the functional reliability and durability of the insulators. Influences of the total alumina, -Al2O3 (corundum) and -quartz contents, microstructural features including morphologies of mullite needles, quartz and corundum grains in the alumino silicate glassy matrix, large inhomogeneities in matrix constituents and composition have been highlighted.

  15. 瓷绝缘子表面激光损伤的数值模拟和实验研究%Numerical simulation and experiment research of laser damage of porcelain insulator surface

    Institute of Scientific and Technical Information of China (English)

    齐丽君; 朱晓; 朱长虹; 郭飞; 朱广志; 谷山强

    2011-01-01

    During the process of laser de-icing applied in the electric grid, the electrical equipment such as insulator should not be damaged by the laser. The temperature and stress field distributions of normal porcelain, alumina porcelain, zirconium oxide porcelain and cordierite porcelain after laser irradiating are obtained by using ANSYS software. The results show that alumina porcelain has advantages in characteristics of anti-damage of thermal induced stress. The experiments of surface damage of insulator with Nd: YAG laser irradiation are explored. The relations between surface temperature and irradiating time are obtained. So is the damage form. Numerical analysis and experiment results are both show that laser power density and irradiating time are considered as the important influence factors of laser damage of the insulator. Thermal damage and thermal-stress damage are the main types of laser damage of porcelain insulator, which are related to the surface temperature after laser irradiation. The anti-damage methods of aiming and controlling, combining laser de-icing with other de-icing methods to protect the insulator are also proposed.%为了防止输电线路激光除冰过程中激光损伤绝缘子等电力设备,采用有限元分析软件ANSYS对激光与普通瓷、氧化铝瓷、氧化锆瓷、堇青石瓷作用后的温度场和应力场进行了数值模拟,得到氧化铝瓷具有较好的抗热应力破坏性能,并进行了Nd∶ YAG激光照射绝缘子表面实验,得到绝缘子表面温度与照射时间和损伤类型的关系.结果表明,激光功率密度和照射时间是影响绝缘子破坏的重要因素,瓷绝缘子表面损伤包括热损伤和热应力破坏,破坏类型与表面温度相关.提出了瞄准、控制、激光除冰与其它除冰方式相结合等保护措施.这一结果对输电线路激光除冰工程应用中保障电力设施的安全是有帮助的.

  16. A comparison of fracture resistance of endodontically treated teeth restored with bonded partial restorations and full-coverage porcelain-fused-to-metal crowns.

    Science.gov (United States)

    Gupta, Abhishek; Musani, Smita; Dugal, Ramandeep; Jain, Nikhil; Railkar, Bhargavi; Mootha, Ajay

    2014-01-01

    The aim of this study was to evaluate the use of bonded partial restorations compared with full-coverage porcelain-fused-to-metal (PFM) crowns as a viable treatment option for endodontically treated posterior teeth. Forty-five recently extracted maxillary first premolars were collected, endodontically treated, and mounted in acrylic blocks. The specimens were randomly divided into three groups and prepared to receive their respective restorations. The teeth in group 1 received full-coverage porcelain-fused-to-metal crowns. The teeth in group 2 received bonded partial restorations made from pressed ceramics (lithium disilicate) involving a functional cusp (palatal). Finally, group 3 received bonded partial restorations made from pressed ceramics involving the buccal cusp and keeping a functional cusp (palatal) intact. All group 1 restorations were cemented using glass ionomer cement. Restorations in groups 2 and 3 were bonded using a dual-cured resin cement. All specimens were subjected to an aging process and tested for shear bond strength using a universal loading machine. The mean force applied in Newtons to cause failure for group I was 674.90 ± 94.16 N, for group 2, 463.46 ± 61.11 N, and for group 3, 849.33 ± 68.92 N. P values obtained using one-way analysis of variance showed a highly significant difference between groups 2 and 3 (P = .001), groups 1 and 2 (P = .001), and groups 1 and 3 (P = .001). The fracture modes observed in all groups involved restorations and tooth fracture. This in vitro study suggests that endodontically treated posterior teeth with intact functional cusps can be restored with bonded partial porcelain restorations. However, if the loss of tooth structure involves the functional cusp, full-coverage PFM crowns are the treatment of choice.

  17. Higher concentration of CO2 and 37℃ stabilize the less virulent opaque cell of Candida albicans

    Institute of Scientific and Technical Information of China (English)

    LIU Ze-hu; LI Min; LU Xue-lian; SHE Xiao-dong; HU Su-quan; CHEN Wei; LIU Wei-da

    2010-01-01

    Background Candida albicans (C. albicans) strains can spontaneously switch at a very low frequency from white to opaque phase. The ability to switch reversibly between white and opaque phenotype and contributes to the pathogenicity of C. albicans. White and opaque switching can be induced by various environmental signals. Previous study showed that opaque cells switch en masse to white when transferred in vitro to 37℃, the temperature of their animal host. The objective of the present study was to determine the effect of different concentration of carbon dioxide and temperature on white-opaque switching, and to determine the different anti-candida killing activity of white and opaque form by human monocyte-macrophage cell line THP-1.Methods White-opaque switching and opaque-white switching were assayed. Modified Lee's medium supplemented with phloxine B was used to detect white and opaque forms of C. albicans under 0.03% CO2 at 25℃, 0.03% CO2 at 37℃ and 5% CO2 at 37℃. Growth curve of C. albicans was monitored using OD value at 630 nm simultaneously. White and opaque forms of C. albicans and THP-1 cells were cocultured at ratio of 1:10. Colony serial dilutions were used to assay for intracellular candidacidal activity. MTT assay was used to measure the extracellular candidacidal activity.Results Phenotype switching was successfully induced in vitro in all three strains of C. albicans. When evaluating white to opaque switching, opaque colony proportion of all colonies was 0.572±0.087, 0.920±0.030 and 0.985±0.026 exposure of white cells to 0.03% CO2 at 25℃, 0.03% CO2 at 37℃ and 5% CO2 at 37℃. When evaluating opaque to white switching, opaque colony proportion of all colonies was 0.600±0.114, 0.983±0.003 and 0.998±0.003 exposure of white cells to 0.03% CO2 at 25℃, 0.03% CO2 at 37℃ and 5% CO2 at 37℃. No significant difference of white or opaque form growth rate was found among three conditions (P>0.05). THP-1 mediated

  18. Effect of titania on fired characteristics of triaxial porcelain

    Indian Academy of Sciences (India)

    Sunipa Bhattacharyya; Swapan Kumar Das; Nirendra Krishna Mitra

    2005-08-01

    Titania was progressively added in the range 3–9 wt% into a triaxial porcelain body consisting of clay, quartz and feldspar. The composed bodies were heated at five different temperatures in the range 1200–1400°C and their fired properties as well as phases evolved were studied. The results revealed that beyond 1300°C, formation of more liquid phases caused bloating in samples which led to generation of pores. This effect is more pronounced in TiO2 containing samples. In the present system, 1300°C appeared to be the optimum temperature at which porosity was almost negligible and strength was maximum (45 MPa), particularly in presence of TiO2. From the results of XRD studies, it was revealed that quartz content primarily decreased with increase in TiO2 content due to excess glass formation and its subsequent dissolution. Mullite content increased with increase in TiO2 content. No significant effect was observed beyond 6 wt% addition. Microstructure primarily showed the presence of quartz grain and cluster of smaller sized primary mullite crystals in both the samples without and with TiO2. Very few secondary mullite crystals were also observed. SEM picture of sample containing 9 wt% TiO2 showed some grain boundary crack due to cooling stress generated in the glassy phase. The drastic reduction of residual strength after 8 cycles of heating at 800°C and cooling particularly in TiO2 containing samples suggests controlled heat treatment of the vitrified samples necessary to promote secondary crystallization process for the enhancement of strength. Attempts have also been made to correlate the constitutional parameters with the properties.

  19. Probing the mechanical properties of dental porcelain through nanoindentation

    Science.gov (United States)

    Manda, Marianthi; Moschakis, Nikolaos; Konstantinidis, Avraam; Christophilos, Demetrios; Papadopoulou, Lambrini; Koidis, Petros; Aifantis, Elias

    2012-11-01

    The purpose of this short communication is to report on some micro/nanoscale aspects of the mechanical behavior of dental porcelain. Specimens were characterized by micro-Raman spectroscopy and scanning electron microscopy (SEM) coupled with energy dispersive spectroscopy (EDS). Massive nanoindentation experiments on the surface of the specimens were performed, and typical load-displacement or load-depth (P-h) curves were obtained, which in turn were used to determine the Young modulus (E) and nanoindentation hardness (n-H), based on the Oliver-Pharr method [1]. Statistical analyses were carried out to determine the Spearman’s rank correlation coefficient (Spearman’s ρ), along with non-parametric linear regression analysis by employing Kolmogorov-Smirnov and Two-Step Cluster tests. Densification due to grain boundary diffusion and open-pore elimination was revealed by SEM. EDS analysis indicated a leucite-dispersed silicate glass matrix, as well as its contamination by traces of other minerals. Raman spectroscopy supported the EDS assignments. The P-h curves suggested that inelastic deformation and material flow increases at larger depths. Spearman’s ρ value showed strong dependence of E and n-H on h, indicating the occurrence of a size effect. The logarithmic data of E and n-H as functions of h were fitted by using linear regression analysis. The data did not obey a normal distribution (as the Kolmogorov-Smirnov test showed) due to the chemical heterogeneity involved. The Two-Step Cluster analysis indicated clustering in four groups associated with the chemical heterogeneity of the surface. Similar works using nanoindentation to determine the mechanical properties of dental materials can be found, for example, in [2, 3]. Corresponding methods for extracting the values of E and n-H from P-h experimental curves can be found, for example, in [4-6].

  20. Enamel thickness after preparation of tooth for porcelain laminate.

    Directory of Open Access Journals (Sweden)

    Ayoub Pahlevan

    2014-08-01

    Full Text Available In this investigation the thickness of enamel in the gingival, middle, and incisal thirds of the labial surface of the anterior teeth were measured regarding preparation of the teeth for porcelain laminate veneers.Part one, 20 extracted intact human maxillary central and lateral incisors ten of each were selected. The teeth were imbedded in autopolimerize acrylic resin. Cross section was preformed through the midline of the incisal, middle and cervical one-third of the labial surface of the teeth. The samples were observed under reflected stereomicroscope and the thickness of enamel was recorded. Part II, the effect of different types of preparation on dentin exposure was evaluated. Thirty maxillary central incisor teeth were randomly divided into two groups: A: Knife-edge preparation. B: Chamfer preparation. All samples were embedded in autopolimerize acrylic resin using a silicon mold. The samples were cut through the midline of the teeth. The surface of the samples were polished and enamel and dentin were observed under the stereomicroscope.Data were analyzed by ANOVA-one way test. The results of this study showed that the least enamel thickness in the central incisor was 345 and in lateral incisor is 235 μ this thickness is related to the one-third labial cervical area. Maximum thickness in maxillary central and lateral incisors in the one-third labial incisal surface was 1260 μ and 1220μ, respectively. In the second part of the study, the tendency of dentinal exposure was shown with the chamfer preparation, but no dentinal exposure was found in the knife-edge preparation. The differences between groups were significant (p<0.05.The knowledge of enamel thickness in different part of labial surface is very important. The thickness of enamel in the gingival area does not permit a chamfer preparation. The knife edge preparation is preferable in gingival area.

  1. Effects of sandblasting and electrical discharge machining on porcelain adherence to cast and machined commercially pure titanium.

    Science.gov (United States)

    Inan, Ozgür; Acar, Asli; Halkaci, Selçuk

    2006-08-01

    The aim of this study was to determine the effect of sandblasting and electrical discharge machining (EDM) on cast and machined titanium surfaces and titanium-porcelain adhesion. Twenty machined titanium specimens were prepared by manufacturer (groups 1 and 2). Thirty specimens were prepared with autopolymerizing acrylic resin. Twenty of these specimens (groups 3 and 4) were cast with commercially pure titanium and the alpha-case layer was removed. For control group (group 5), 10 specimens were cast by using NiCr alloy. Groups 2 and 4 were subjected to EDM while groups 1, 3, and 5 were subjected to sandblasting. Surface examinations were made by using a scanning electron microscope (SEM). A low-fusing porcelain was fused on the titanium surfaces, whereas NiCr specimens were covered using a conventional porcelain. Titanium-porcelain adhesion was characterized by a 3-point bending test. Results were analyzed by Kruskal-Wallis and Mann-Whitney U tests. Metal-porcelain interfaces were characterized by SEM. The bond strength of control group was higher than that of the titanium-porcelain system. There was no significant difference between cast and machined titanium groups (p > 0.05). There was no significant difference between EDM and sandblasting processes (p > 0.05). The use of EDM as surface treatment did not improve titanium-porcelain adhesion compared with sandblasting.

  2. Comparative study of white porcelain from the common use of nineteenth and twentieth centuries with PXRF

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Wislley Dueli da; Appoloni, Carlos Roberto [Universidade Estadual de Londrina (UEL), PR (Brazil)

    2011-07-01

    Full text: The technique of X-ray fluorescence (XRF) is widely used for qualitative and quantitative researches on the chemical composition of various types of samples, such as archaeological, art and cultural heritage materials or samples. The great advantage of this technique is that it allows a nondestructive and simultaneous multielement analysis. It has a low cost and portable system device that can be used in situ. The study of archaeological artifacts and cultural heritage by means of analytical techniques with hand held devices becomes increasingly routine today. Several types of portable energy dispersive X-ray fluorescence (EDXRF) have been used in many different situations involving in situ analysis covering a wide range of geometries, detectors, voltage and current applied in the X-ray tubes. This study aims to identify and compare the main elements that make up samples of ceramic pottery for common use by the late nineteenth and early and late twentieth century, as a way of using the methodology of analysis by EDXRF equipment PXRF - LFNA - 02. Being able to identify that the key element present in the glaze of ceramics from the early twentieth century was the Pb, it was possible to classify the samples as faience cream ware and not pearlware as it was guided by conventional archaeological analysis, where the rating was based only on color enamel porcelain. Elements such as K, Ca, Cr, Mn, Fe, Co, Zn, Rb, Sr, Zr are also found in different concentrations depending on the clay used in the manufacture of earthenware, maker of the period and that it was produced. From analysis of the type EDXRF is possible to compare different manufacturing techniques, both in enamel and in ceramic slurry and often even the color of his pieces. (author)

  3. Activation of the Cph1-dependent MAP kinase signaling pathway induces white-opaque switching in Candida albicans.

    Directory of Open Access Journals (Sweden)

    Bernardo Ramírez-Zavala

    Full Text Available Depending on the environmental conditions, the pathogenic yeast Candida albicans can undergo different developmental programs, which are controlled by dedicated transcription factors and upstream signaling pathways. C. albicans strains that are homozygous at the mating type locus can switch from the normal yeast form (white to an elongated cell type (opaque, which is the mating-competent form of this fungus. Both white and opaque cells use the Ste11-Hst7-Cek1/Cek2 MAP kinase signaling pathway to react to the presence of mating pheromone. However, while opaque cells employ the transcription factor Cph1 to induce the mating response, white cells recruit a different downstream transcription factor, Tec1, to promote the formation of a biofilm that facilitates mating of opaque cells in the population. The switch from the white to the opaque cell form is itself induced by environmental signals that result in the upregulation of the transcription factor Wor1, the master regulator of white-opaque switching. To get insight into the upstream signaling pathways controlling the switch, we expressed all C. albicans protein kinases from a tetracycline-inducible promoter in a switching-competent strain. Screening of this library of strains showed that a hyperactive form of Ste11 lacking its N-terminal domain (Ste11(ΔN467 efficiently stimulated white cells to switch to the opaque phase, a behavior that did not occur in response to pheromone. Ste11(ΔN467-induced switching specifically required the downstream MAP kinase Cek1 and its target transcription factor Cph1, but not Cek2 and Tec1, and forced expression of Cph1 also promoted white-opaque switching in a Wor1-dependent manner. Therefore, depending on the activation mechanism, components of the pheromone-responsive MAP kinase pathway can be reconnected to stimulate an alternative developmental program, switching of white cells to the mating-competent opaque phase.

  4. Art Nouveau Yıldız Porcelains Exhibited at Ankara Ethnography Museum Collection

    Directory of Open Access Journals (Sweden)

    Suna Canan Aydın Altay

    2014-12-01

    Full Text Available Yıldız Çini Fabrika-i Hümayunu (Yıldız Imperial Porcelain Factory was established on the orders of Sultan Abdulhamid II at the beginning of the 1890s in the Yıldız Palace garden. While this was an important step in the history of Ottoman industry it also created a prestige against western societies. From the date the production was started in 1894 until it was closed in 1909, unique works of the Ottoman modernization era have been produced at Yıldız Çini Fabrika-i Hümayunu (Yıldız Imperial Porcelain Factory. The porcelain objects produced under the influence of the Art Nouveau movement in Europe within this 15 years period, especially in the second half of the 19th century,are quite remarkable. These works have been distributed among various museums and collections and a group of them are exhibited at the Ankara Ethnography Museum’s Porcelain Collection. In this research, Art Nouveau works in this museum’s collection are examined and evaluated.

  5. Alkali-ions diffusion, mullite formation, and crystals dissolution during sintering of porcelain bodies: Microstructural approach

    DEFF Research Database (Denmark)

    Leonelli, C.; Kamseu, E.; Boccaccini, Dino

    2009-01-01

    The effect of alkali-silicate glassy matrix as replacement for feldspar in soft and hard porcelain compositions was studied. SEM and X-ray diffraction analysis were used to evidence phase evolution. For each composition, the influence of soaking time was evaluated. The difference in chemical...

  6. Efficacy of Experimental Hydrofluoric Acid (HF on Bond Strength and Microleakage of Composite-Porcelain Interface

    Directory of Open Access Journals (Sweden)

    Samaneh Mahvidyzadeh

    2012-09-01

    Full Text Available Background and Aims: The aim of this study was to evaluate the quality of an experimental hydrofluoric acid (HF for preparation of porcelain and to compare it with two commercial hydrofluoric acids in Iranian trademark. Materials and Methods: A- Evaluation of etch pattern of experimental HF using scanning electron microscope (SEM: 6 feldespathic discs were divided into 3 groups. Each group was etched with related HF (experimental, Ultradent and Kimia for 1 minute. SEM images were recorded at 3 magnifications. B- Bond strength test: 18 feldespathic discs were considered for each acidic group. Then the porcelain surfaces were etched and bonded to composite with unfilled resin. Consequently, the microshear test was done. C- Microleakage test: 54 discs were divided into 3 groups (n=18. Then the porcelain surfaces were etched and bonded to composite with unfilled resin and finally observed under stereomicroscope. The data were analyzed with one-way ANOVA and Smirnov tests. Results: SEM analysis showed no difference between groups in terms of etch pattern. Microshear bond strength values for experimental, Kimia, and Ultradent HF were 28.53 (±4.92, 28.21 (±6.61, and 26.14 (±7.61 MPa, respectively. There was no significant difference between the bond strength of test groups (P0.05. Conclusion: Quality of experimental HF in terms of etch pattern, microshear bond strength and microleakage of composite/porcelain interface was similar to that of two commercial hydrofluoric acids.

  7. Color management of porcelain veneers: influence of dentin and resin cement colors

    NARCIS (Netherlands)

    Dozic, A.; Tsagkari, M.; Khashayar, G.; Aboushelib, M.

    2010-01-01

    Objective: Porcelain veneers have become an interesting treatment option to correct the shape and color of anterior teeth. Because of their limited thickness and high translucency, achieving a good color match is influenced by several variables. The aim of this work was to investigate the influence

  8. Esthetic Rehabilitation of Anterior Teeth with Porcelain Laminates and Sectional Veneers

    NARCIS (Netherlands)

    Gresnigt, Marco; Ozcan, Mutlu

    2011-01-01

    Full-coverage bonded porcelain restorations offer predictable treatment options in dentistry, but a certain amount of tooth material must be removed to allow space for the required thickness of the restorative material. Laminate veneers and inlays are considered minimally invasive, but they also req

  9. Effect of different sources of alumina on the microstructure and mechanical properties of the triaxial porcelain

    Directory of Open Access Journals (Sweden)

    G. Gralik

    2014-12-01

    Full Text Available Porcelains composed of kaolin-quartz-feldspar are called triaxial porcelains. The use of alumina as a substitute for quartz in porcelains has been developed for some time. The results show a significant improvement in their mechanical properties, but alumina has a high cost. The possibility of using alternative materials as a source of alumina with lower cost was investigated. In this work, alternative raw materials were used as a source of alumina: refractory bauxite, primary aluminum hydroxide, reprecipitated aluminum hydroxide. Compositions with commercial alumina and quartz were also formulated to better understand the effects of adding these alternative materials. The raw materials were milled, dried, and characterized by analysis of the particle size distribution, X-ray diffraction, and X-ray fluorescence. The compositions were formulated by replacing the different sources of alumina in the formulation of porcelain. The compositions studied were shaped by pressing and sintered at different temperatures (1150-1400 ºC. The results showed that the use of bauxite and aluminum hydroxide as an alternative source of Al2O3 is viable. The impurities contained in refractory bauxite contributed to the lower values of flexural strength found in compositions having refractory bauxite as a source of alumina. The compositions with reprecipitated aluminum hydroxide showed a high mechanical resistance at low sintering temperatures, while compositions with aluminum hydroxide obtained by the Bayer process achieved good results of mechanical strength in a wide temperature range.

  10. Evaluation of flexural bond strength of porcelain to used nickel-chromium alloy in various percentages

    Directory of Open Access Journals (Sweden)

    VNV Madhav

    2012-01-01

    Fresh nickel-chromium alloy shows the greatest porcelain adherence.There is no significant change in bond strength of ceramic to alloy with up to 75% of used nickel-chromium alloy.At least 25%- of new alloy should be added when recycled nickel-chromium alloy is being used for metal ceramic restorations.

  11. The effect of manufacturing variables on radiation doses from porcelain tiles.

    Science.gov (United States)

    Selby, J H; Strydom, R

    2008-06-01

    Previous studies have focused on the radiological properties of glazed ceramic tiles. This study was conducted to describe the radiological properties of porcelain tiles and how they were affected by variations in the manufacturing parameters. The data showed that the majority of the uranium in the tiles was attributable to the addition of zircon while less than half of the thorium in the tile was attributable to the added zircon, and the remainder came from other minerals in the formulation. The effects of firing temperatures and compressive strengths of the tiles are presented and show that higher firing temperatures increase radon emanation, while higher compressive strengths reduce radon emanation. The study also described how the addition of zircon to the tile formulation affected the radiological exposures that could be received by a member of the public from the use of such porcelain tiles. A dose assessment was conducted based on 23 different types of tile formulation. Screening procedures for building materials have been described in European Commission documents, and these limit the addition of zircon in a porcelain tile to approximately 9% by mass. The dose assessment reported in this study showed that 20% zircon could be added to a porcelain tile without exceeding the prescribed dose limits.

  12. Improving shear bond strength between feldspathic porcelain and zirconia substructure with lithium disilicate glass-ceramic liner.

    Science.gov (United States)

    Wattanasirmkit, Kamolporn; Srimaneepong, Viritpon; Kanchanatawewat, Kanchana; Monmaturapoj, Naruporn; Thunyakitpisal, Pasutha; Jinawath, Supatra

    2015-01-01

    This study investigated the shear bond strength (SBS) between veneering porcelain and zirconia substructure using lithium disilicate glass-ceramic as a liner. The mineral phases and microstructures of lithium disilicate glass-ceramic at temperature range of 800-900°C were preliminarily investigated. SBSs of porcelain-veneered zirconia specimens with and without lithium disilicate glassceramic liner fired at the same temperature were determined. Results showed that SBSs of veneering porcelain and zirconia with lithium disilicate glass-ceramic liner was notably increased (pporcelain and zirconia.

  13. SHEAR BOND STRENGTH OF BRACKETS BONDED TO PORCELAIN SURFACE: IN VITRO STUDY

    Directory of Open Access Journals (Sweden)

    Fidan Alakuş Sabuncuoğlu

    2016-01-01

    Full Text Available Purpose: To compare the effects of different porcelain surface treatment methods on the shear bond strength (SBS and fracture mode of orthodontic brackets. Materials and Methods: Seventy feldspathic porcelain disk samples mounted in acrylic resin blocks were divided into seven groups (n=10 according to type of surface treatment: I, Diamond bur; II, Orthosphoric acid (OPA; III, hydrofluoric acid (HFA; IV, sandblasted with aluminum oxide (SB; V, SB+HFA; VI, Neodymium:yttrium-aluminum-garnet (Nd:YAG laser; VII, Erbium:yttrium-aluminum-garnet (Er:YAG laser. Brackets were affixed to treated all-porcelain surfaces with a silane bonding agent and adhesive resin and subjected to SBS testing. Specimens were evaluated according to the adhesive remnant index (ARI, and failure modes were assessed quantitatively under a stereomicroscope and morphologically under a scanning electron microscope (SEM. Statistical analysis was performed using one-way analysis of variance and the post-hoc Tukey test, with the significance level set at 0.05. Results: The highest SBS values were observed for Group V, with no significant difference between Groups V and III. SBS values for Group I were significantly lower than those of all other groups tested. The porcelain/resin interface was the most common site of failure in Group V (40% and Group III (30%, whereas other groups showed various types of bond failure, with no specific location pre-dominating, but with some of the adhesive left on the porcelain surfaces (ARI scores 2 or 3 in most cases. Conclusion: The current findings indicate that a diamond bur alone is unable to sufficiently etch porcelain surfaces for bracket bonding. Moreover, SB and HFA etching used in combination results in a significantly higher shear-bond strength than HFA or SB alone. Finally, laser etching with either an Nd:YAG or Er:YAG laser was found to be more effective and less time-consuming than both HFA acid and SB for the treatment of deglazed

  14. Effect of experimental parameters on optimal reflection of light from opaque media

    CERN Document Server

    Anderson, Benjamin R; Eilers, Hergen

    2016-01-01

    Previously we considered the effect of experimental parameters on optimized transmission through opaque media using spatial light modulator (SLM)-based wavefront shaping. In this study we consider the opposite geometry, in which we optimize reflection from an opaque surface such that the backscattered light is focused onto a spot on an imaging detector. By systematically varying different experimental parameters (genetic algorithm iterations, bin size, SLM active area, target area, spot size, and sample angle with respect to the optical axis) and optimizing the reflected light we determine how each parameter affects the intensity enhancement. We find that the effects of the experimental parameters on the enhancement are similar to those measured for a transmissive geometry, but with the exact functional forms changed due to the different geometry and the use of a genetic algorithm instead of an iterative algorithm. Additionally, we find preliminary evidence of greater enhancements than predicted by random mat...

  15. Preparation and evaluation of dental resin with antibacterial and radio-opaque functions.

    Science.gov (United States)

    He, Jingwei; Söderling, Eva; Vallittu, Pekka K; Lassila, Lippo V J

    2013-03-07

    In order to prepare antibacterial and radio-opaque dental resin, a methacrylate monomer named 2-Dimethyl-2-dodecyl-1-methacryloxyethyl ammonium iodine (DDMAI) with both antibacterial and radio-opaque activities was added into a 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropyl)-phenyl]propane (Bis-GMA)/methyl methacrylate (MMA) dental resin system. Degree of conversion (DC), flexural strength (FS) and modulus (FM), water sorption (WS) and solubility (WSL), antibacterial activity, and radio-opacity (ROX) of the obtained dental resin system were investigated. Bis-GMA/MMA resin system without DDMAI was used as a control. The results showed that DDMAI could endow BIS-GMA/MMA resin system with good antibacterial (p 0.05). However, incorporating DDMAI into Bis-GMA/MMA resin could reduce mechanical properties (p < 0.05) and increase WS and WSL (p < 0.05), thus further work is needed in order to optimize the resin formulation.

  16. Preparation and Evaluation of Dental Resin with Antibacterial and Radio-Opaque Functions

    Directory of Open Access Journals (Sweden)

    Pekka K. Vallittu

    2013-03-01

    Full Text Available In order to prepare antibacterial and radio-opaque dental resin, a methacrylate monomer named 2-Dimethyl-2-dodecyl-1-methacryloxyethyl ammonium iodine (DDMAI with both antibacterial and radio-opaque activities was added into a 2,2-bis[4-(2-hydroxy-3-methacryloyloxypropyl-phenyl]propane (Bis-GMA/methyl methacrylate (MMA dental resin system. Degree of conversion (DC, flexural strength (FS and modulus (FM, water sorption (WS and solubility (WSL, antibacterial activity, and radio-opacity (ROX of the obtained dental resin system were investigated. Bis-GMA/MMA resin system without DDMAI was used as a control. The results showed that DDMAI could endow BIS-GMA/MMA resin system with good antibacterial (p 0.05. However, incorporating DDMAI into Bis-GMA/MMA resin could reduce mechanical properties (p < 0.05 and increase WS and WSL (p < 0.05, thus further work is needed in order to optimize the resin formulation.

  17. Diversity of yeasts involved in the fermentation of tchoukoutou, an opaque sorghum beer from Benin

    OpenAIRE

    Kayode, A. P. P.; Vieira-Dalode, G.; Linnemann, A.R.; Kotchoni, S.O.; Hounhouigan, A.J.D.; Boekel, van, E.M.P.M.; Nout, M.J.R.

    2011-01-01

    Opaque sorghum beers are traditional alcoholic beverages in several African countries. Known as tchoukoutou in Benin, the beer is often obtained from an uncontrolled fermentation. It is consumed in an actively fermenting state and has a sour taste. The present study characterized and identified the yeasts involved in the fermentation process of this type of beer using the phenotypical approach. Of 12 beers from 4 different locations, the mean values of the pH, titratable acidity, dry matter c...

  18. Comparison of porcelain surface and flexural strength obtained by microwave and conventional oven glazing.

    Science.gov (United States)

    Prasad, Soni; Monaco, Edward A; Kim, Hyeongil; Davis, Elaine L; Brewer, Jane D

    2009-01-01

    Although the superior qualities of microwave technology are common knowledge in the industry, effects of microwave glazing of dental ceramics have not been investigated. The purpose of this study was to investigate the surface roughness and flexural strength achieved by glazing porcelain specimens in a conventional and microwave oven. Thirty specimens of each type of porcelain (Omega 900 and IPS d.Sign) were fabricated and sintered in a conventional oven. The specimens were further divided into 3 groups (n=10): hand polished (using diamond rotary ceramic polishers), microwave glazed, and conventional oven glazed. Each specimen was evaluated for surface roughness using a profilometer. The flexural strength of each specimen was measured using a universal testing machine. A 2-way ANOVA and Tukey HSD post hoc analysis were used to determine significant intergroup differences in surface roughness (alpha=.05). Flexural strength results were also analyzed using 2-way ANOVA, and the Weibull modulus was determined for each of the 6 groups. The surfaces of the specimens were subjectively evaluated for cracks and porosities using a scanning electron microscope (SEM). A significant difference in surface roughness was found among the surface treatments (P=.02). Follow-up tests showed a significant difference in surface roughness between oven-glazed and microwave-glazed treatments (P=.02). There was a significant difference in flexural strength between the 2 porcelains (Pmicrowave-glazed group was the highest (1.9) as compared to the other groups. The surface character of microwave-glazed porcelain was superior to oven-glazed porcelain. Omega 900 had an overall higher flexural strength than IPS d.Sign. Weibull distributions of flexural strengths for Omega 900 oven-glazed and microwave-glazed specimens were similar. SEM analysis demonstrated a greater number of surface voids and imperfections in IPS d. Sign as compared to Omega 900.

  19. Discovery of the gray phenotype and white-gray-opaque tristable phenotypic transitions in Candida dubliniensis.

    Science.gov (United States)

    Yue, Huizhen; Hu, Jian; Guan, Guobo; Tao, Li; Du, Han; Li, Houmin; Huang, Guanghua

    2016-04-02

    Candida dubliniensis is closely related to Candida albicans, a major causative agent of candidiasis, and is primarily associated with oral colonization and infection in human immunodeficiency virus (HIV)-positive patients. Despite the high similarity of genomic and phenotypic features between the 2 species, C. dubliniensis is much less virulent and less prevalent than C. albicans. The ability to change morphological phenotypes is a striking feature of Candida species and is linked to virulence. In this study, we report a novel phenotype, the gray phenotype, in C. dubliniensis. Together with the previously reported white and opaque cell types, the gray phenotype forms a tristable phenotypic switching system in C. dubliniensis that is similar to the white-gray-opaque tristable switching system in C. albicans. Gray cells of C. dubliniensis are similar to their counterparts in C. albicans in terms of several biological aspects including cellular morphology, mating competence, and genetic regulatory mechanisms. However, the gray phenotypes of the 2 species have some distinguishing features. For example, the secreted aspartyl protease (Sap) activity is induced by bovine serum albumin (BSA) in gray cells of C. albicans, but not in gray cells of C. dubliniensis. Taken together, our results demonstrate that the biological features and regulatory mechanisms of white-gray-opaque tristable transitions are largely conserved in the 2 pathogenic Candida species.

  20. Possibilities and limitations of the ART-Sample algorithm for reconstruction of 3D temperature fields and the influence of opaque obstacles.

    Science.gov (United States)

    Li, Yuanyang; Herman, Cila

    2013-07-01

    The need for the measurement of complex, unsteady, three-dimensional (3D) temperature distributions arises in a variety of engineering applications, and tomographic techniques are applied to accomplish this goal. Holographic interferometry (HI), one of the optical methods used for visualizing temperature fields, combined with tomographic reconstruction techniques requires multi-directional interferometric data to recover the 3D information. However, the presence of opaque obstacles (such as solid objects in the flow field and heaters) in the measurement volume, prevents the probing light beams from traversing the entire measurement volume. As a consequence, information on the average value of the field variable will be lost in regions located in the shade of the obstacle. The capability of the ART-Sample tomographic reconstruction method to recover 3D temperature distributions both in unobstructed temperature fields and in the presence of opaque obstacles is discussed in this paper. A computer code for tomographic reconstruction of 3D temperature fields from 2D projections was developed. In the paper, the reconstruction accuracy is discussed quantitatively both without and with obstacles in the measurement volume for a set of phantom functions mimicking realistic temperature distributions. The reconstruction performance is optimized while minimizing the number of irradiation directions (experimental hardware requirements) and computational effort. For the smooth temperature field both with and without obstacles, the reconstructions produced by this algorithm are good, both visually and using quantitative criteria. The results suggest that the location and the size of the obstacle and the number of viewing directions will affect the reconstruction of the temperature field. When the best performance parameters of the ART-Sample algorithm identified in this paper are used to reconstruct the 3D temperature field, the 3D reconstructions with and without obstacle are

  1. Further study of sources of the imported cobalt-blue pigment used on Jingdezhen porcelain from late 13 to early 15 centuries

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Based on the conclusion of modern scientific analysis: the cobalt-blue pigment applied on Jingdezhen official porcelain during Yuan Dynasty and prior to Xuande reign of Ming Dynasty (1271―1425) contains high iron and low manganese con- tents, and the cobalt during Xuande and after Xuande periods (after 1426) of Ming Dynasty contains high manganese and low iron contents, in combination with the traditional archaeological method, the related historical textual records were in- vestigated and analyzed, the imported cobalt employed on Jingdezhen official porcelain was studied comprehensively, systematically and logically. In fact, ’Su Ma Li Qing’ (Samarra-blue) and ’Su Bo Ni Qing’ (Sumatra-blue) are definitely different cobalt ores originated in different places, because of their very similar translitera- tions in Chinese, the confusion has appeared in ancient books for more than 400 years, which considered ’Su Ma Li Qing’ and ’Su Bo Ni Qing’ as the same co- balt-blue pigment. In this article the mistake was corrected, the possible producing places and the approximate eras of the two pigments imported to China and used at Jingdezhen were also suggested.

  2. Further study of sources of the imported cobalt-blue pigment used on Jingdezhen porcelain from late 13 to early 15 centuries

    Institute of Scientific and Technical Information of China (English)

    DU Feng; SU BaoRu

    2008-01-01

    Based on the conclusion of modern scientific analysis: the cobalt-blue pigment applied on Jingdezhen official porcelain during Yuan Dynasty and prior to Xuande reign of Ming Dynasty (1271-1425) contains high iron and low manganese contents,and the cobalt during Xuande and after Xusnde periods (after 1426) of Ming Dynasty contains high manganese and low iron contents,in combination with the traditional archaeological method,the related historical textual records were in vestigated and analyzed,the imported cobalt employed on Jingdezhen official porcelain was studied comprehensively,systematically and logically. In fact,'Su Ma Li Qing' (Samarra-blue) and 'Su Bo Ni Qing' (Sumatra-blue) are definitely different cobalt ores originated in different places,because of their very similar translitera tions in Chinese,the confusion has appeared in ancient books for more than 400 years,which considered 'Su Ma Li Qing' and 'Su Bo Ni Qing' as the same cobait-blue pigment. In this article the mistake was corrected,the possible producing places and the approximate eras of the two pigments imported to China and used at Jingdezhen were also suggested.

  3. Porcelain laminate veneer restorations bonded with a three-liquid silane bonding agent and a dual-activated luting composite.

    Science.gov (United States)

    Matsumura, Hideo; Aida, Yukiko; Ishikawa, Yumi; Tanoue, Naomi

    2006-12-01

    This clinical report describes the fabrication and bonding of porcelain laminate veneer restorations in a patient with anterior open spaces. Laminate veneer restorations made of feldspathic porcelain were etched with 5% hydrofluoric acid, rinsed under tap water, ultrasonically cleaned with methanol, and primed with a chemically activated three-liquid silane bonding agent (Clearfil Porcelain Bond). The enamel surfaces were etched with 40% phosphoric acid, rinsed with water, and primed with a two-liquid bonding agent (Clearfil New Bond) that contained a hydrophobic phosphate (10-methacryloyloxydecyl dihydrogen phosphate; MDP). The restorations were bonded with a dual-activated luting composite (Clapearl DC). The veneers have been functioning satisfactorily for an observation period of one year. Combined use of the Clearfil bonding agents and Clapearl DC luting composite is an alternative to conventional materials for seating porcelain laminate veneer restorations, although the system is inapplicable to dentin bonding.

  4. Effect of sandblasting on surface roughness of zirconia-based ceramics and shear bond strength of veneering porcelain.

    Science.gov (United States)

    He, Min; Zhang, Zutai; Zheng, Dongxiang; Ding, Ning; Liu, Yan

    2014-01-01

    This study aims to investigate the effect of sandblasting on the surface roughness of zirconia and the shear bond strength of the veneering porcelain. Pre-sintered zirconia plates were prepared and divided into four groups. Group A were not treated at all; group B were first sandblasted under 0.2 MPa pressure and then densely sintered; group C and D were sintered first, and then sandblasted under 0.2 MPa and 0.4 MPa pressures respectively. Surface roughness was measured and 3D roughness was reconstructed for the specimens, which were also analyzed with X-ray diffractometry. Finally after veneering porcelain sintering, shear bond tests were conducted. Sandblasting zirconia before sintering significantly increased surface roughness and the shear bond strength between zirconia and veneering porcelain (pzirconia before sintering is a useful method to increase surface roughness and could successfully improve the bonding strength of veneering porcelain.

  5. [Line scanning analysis of white porcelain from Gong Kiln in early Tang dynasty by energy disperse X-ray fluorescence].

    Science.gov (United States)

    Ling, Xue; Mao, Zhen-wei; Feng, Min; Hu, Yao-wu; Wang, Chang-sui; Liu, Hong-miao

    2005-07-01

    Gong kiln, for its long porcelain-firing history, was one of three representative white porcelain kilns in northern China. In order to improve the quality and whiteness of white porcelain, a decorating layer or cosmetic earth was laid on the body surface in Gong kiln during early Tang dynasty, which was able to blot out rough surface and weaken the influence of fuscous body upon surface color. In this paper the main chemical composition of the white porcelain's profile was analyzed by using energy disperse X-Ray fluorescence. The result showed that different materials were used as cosmetic earth during early Tang dynasty, in accordance with the phenomenon under optical microscope. In addition, the glaze belongs to calcium glaze in which plant ash was added.

  6. Genotoxicity evaluation of locally produced dental porcelain--an in vitro study using the Ames and Comet assays.

    Science.gov (United States)

    Noushad, Mohammed; Kannan, Thirumulu Ponnuraj; Husein, Adam; Abdullah, Haswati; Ismail, Abdul Rashid

    2009-09-01

    The aim of this study was to determine the genotoxicity of a locally produced dental porcelain (Universiti Sains Malaysia, Malaysia) using the Ames and Comet assays. In the Ames assay, four genotypic variants of the Salmonella strains (TA98, TA100, TA1537 and TA1535) carrying mutations in several genes were used. The dental porcelain was incubated with these four strains in five different doses both in the presence and absence of metabolic activation (S9) and the result was assessed based on the number of revertant colonies. Concurrently, appropriate positive controls were used so as to validate the test. The average number of revertant colonies per plate treated with locally produced dental porcelain was less than double as compared to that of negative control. In the Comet assay, L929 (CCL-1 ATCC, USA) mouse fibroblast cells were treated with the dental porcelain in three different concentrations along with concurrent negative and positive controls. The tail moment which was used as a measurement of DNA damage was almost equal to that of the negative control, suggesting that the locally produced dental porcelain did not induce any DNA damage. The results indicated that the locally produced dental porcelain is non-genotoxic under the present test conditions.

  7. Effect of Oxidation and SiO2 Coating on the Bonding Strength of Ti-Porcelain

    Science.gov (United States)

    Guo, Litong; Liu, Xiaochen; Zhu, Yabo; Xu, Cheng; Gao, Jiqiang; Guo, Tianwen

    2010-11-01

    Investigations on the effect of oxidation on titanium-ceramic adhesion were performed. Cast pure titanium was subjected to surface modification by preoxidation and introduction of an intermediate layer of SiO2 by sol-gel process. Specimens were characterized by TG-DSC, XRD, and SEM/EDS. The adhesion between the titanium and porcelain was evaluated by three-point flexure bond test. Failure of the titanium-porcelain with preoxidation treatment predominantly occurred at the titanium-oxide interface. Preoxidation treatment did not affect the fracture mode of the titanium-ceramic system and did not increase the bonding strength of Ti-porcelain. The SEM results revealed the existence of microcracks on the SiO2 coating surface oxidized at 800 °C in an air furnace. During the porcelain fusion, minute amounts of oxygen were able to penetrate the cracks and caused localized oxidation of the Ti-substrate. Failure of the titanium-porcelain with SiO2 coating predominantly occurred at the SiO2 layer. The SiO2 coating served as an effective oxygen diffusion barrier and improved the mechanical and chemical bonding between porcelain and titanium.

  8. Greyish shadow on the labial gingival margin after insertion porcelain fused to metal crown on anterior teeth

    Directory of Open Access Journals (Sweden)

    Ike Damayanti Habar

    2016-06-01

    Full Text Available The crown is the type of restoration that replaces lost tooth structure caused by caries, trauma, or other causes which aims to restore comfort, function and patient confidence. Porcelain fused to metal restorationis an option that dominate the aesthetic restoration crown sand fixed prosthesisover the last 50 years. Porcelain fused to metal crown, consists of porcelain layer bonded to a thin cast metal coping that fits over the tooth preparation. Such a restoration combines the strength  and accurate fit of a cast metal crown with  the cosmetic effect of a porcelain crown. In some cases, it looks greyish shadow on the labial gingival margin after insertion porcelain fused to metal crowns on anterior teeth that can not be hidden even if the placement of the edge in subgingival. The purpose of this case report is to determine the cause of a greyish shadow on the labial gingival margin after insertion porcelain fused to metal crowns on anterior teeth and how to prevent a greyish shadow very disturbing aesthetics of the patient.

  9. Voltage-sharing Characteristics of Porcelain Insulators for 750 kV AC Substation%Voltage-sharing Characteristics of Porcelain Insulators for 750 kV AC Substation

    Institute of Scientific and Technical Information of China (English)

    ZHANG Shi-ting; PENG Zong-ren; LIAO Jin tao

    2011-01-01

    Considering the complex environment in 750 kV AC substation, porcelain insulators have particular electric field and voltage distribution in comparison with those used in AC transmission line, meanwhile, the investigation of a typical 750 kV AC substation located in Lanzhou with ultraviolet imager (UVI) demonstrated that the corona dis- charge of some insulators is serious due to the improper structure design and installation, so research on porcelain insulators used in substation is needed. The three-dimensional finite element method (FEM) 750 kV AC substation calculation model was established to calculate electric field and voltage distribution of insulators, and the voltage distribution curves along insulators which are classified by type and suspension location were obtained using a novel FEM method which can effectively reduce the calculation amount without losing accuracy, meanwhile, the effect of the grading ring for improving voltage distribution of insulators was studied by adjusting the structure parameters of grad- ing ring. Consequently, an optimization structure of rings was proposed by improving the voltage distribution of insu- lator string and reducing the electric strength of grading ring for the purpose of restricting corona noise, and the on- site observations by UVI showed that the newly manufactured and installed grading ring could obviously avoid the occurrences of corona discharge which validates the optimization design. This paper proposed an effective method combi ning UVI observation and FEM calculation to study voltage-sharing characteristics of porcelain insulators, and the results can provide experiences and references for the design of 750 kV AC substation.

  10. Performance of a novel polishing rubber wheel in improving surface roughness of feldspathic porcelain.

    Science.gov (United States)

    Han, Geum-Jun; Kim, Jae-Hoon; Lee, Mi-Ae; Chae, So-Yeon; Lee, Yun-Hee; Cho, Byeong-Hoon

    2014-01-01

    Replacing glazing with polishing is still controversial in terms of the surface roughness of dental porcelains. This study investigated the polishing performance of a ceramic-polishing rubber wheel (CP-RW), which contains large uniform and rounded silicon carbide particles and small diamond particles, in improving the surface roughness of two feldspathic porcelains for sintering and CAD/CAM milling. Using a confocal laser scanning microscopy, the changes in the surface roughness parameters were evaluated before and after polishing or glazing for three surface treatment groups: SofLex polishing, CP-RW polishing, and Glazing. Regardless of the parameters, all treatments reduced roughness values (repeated measures ANOVA, ppolishing were lower than those obtained after SofLex polishing and glazing (2-way ANOVA, pPolishing both ceramics with CP-RW made the surfaces smooth with the lowest roughness values in all parameters. The effect was dependent on the materials used.

  11. [Experimental research on porcelain fused to the surface of pure titanium and titanium alloys].

    Science.gov (United States)

    Wang, D; Ai, S; Xu, J

    1995-07-01

    Titanium material has been widely used in prosthodontics since the end of 1980s. However, the research on porcelain fused to the surfaces of titanium material was quite few. This article introduced the technological process of low-fusing dental porcelain--Ceratin fused to pure titanium and titanium alloys. The values of the bond strength of Ceratin and titanium substrates were obtained by shearing test with INSTRON Model-1185. The average value of the shearing strength between TA2 and Ceratin was 31. 01MPa. The corresponding value between TC4 and Ceratin was 33.73MPa. The interface between Ceratin and titanium substrate was observed with scanning electron microscope (SEM). The results of this research proposed that it is hopeful that Ceratin is used as special procelain with titanium material.

  12. Fractal Characteristics and Fractal Dimension Measurement on Broken Surfaces of Aluminum Electric Porcelain

    Institute of Scientific and Technical Information of China (English)

    YANG Zhiyuan; ZHOU Anning

    2005-01-01

    The characteristics of broken surfaces were researched by a scanning electron microscope (SEM) and a reflection microscope, and the fractal dimensions of broken surfaces were measured by the Slit Island method. The experimental results indicate that the broken surface of aluminum electric porcelain is a fractal body in statistics, and the fractal dimensions of broken surfaces are different with the different amplification multiple value.In all of measured fractal dimensions,both of values measured in 100× under reflection microscope and in 500× under SEM are maximum, whereas the values measured in 63× under reflection microscope and in 2000× under SEM are obviously minimum. The fractal dimensions of broken surfaces are also affected by the degrees of gray comparison and the kinds of measuring methods. The relationships between the fractal dimensions of broken surfaces and porcelain bend strengths are that they are in positive correlation on the low multiples and in negative correlation on the high multiples.

  13. Scientific studies on pottery and pro-porcelain from group of graves in Henglingshan, Guangdong Province

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The findings of the Henglingshan group of graves, Guangdong Province, were appraised as one of the ten major archaeological excavations in 2000. The pottery and proto-porcelain samples excavated from the group of graves in Henglingshan are very important for studying the development history of Guang-dong ceramics. In this paper, the chemical compositions, micro-structure and physical properties of the samples were systematically analyzed. The results were subjected to multivariate statistical analysis. Different compositional patterns were found for specimens from different periods. The reasons for these variations were discussed. In addition, compared with the pottery and proto-porcelain samples from different production sites in other provinces of China, the obvious regional characters and unique law of the development for ancient ceramics of Guangdong were also discussed.

  14. Indirect porcelain veneers in periodontally compromised teeth. The hybrid technique: a case report.

    Science.gov (United States)

    Garcia-Baeza, David; Saavedra, Carlos; Garcia-Adámez, Ramón

    2015-01-01

    The loss of periodontal structure causes an esthetic problem for many patients, especially when the esthetic zone is compromised. Among the various types of solutions is the use of composite resins. While this procedure is not aggressive towards tooth structure, it does require the clinician to have a precise technique, and demands strict longterm maintenance. 1 Another way of treating the compromised teeth is with porcelain veneers. This procedure is especially difficult, however, if carried out on periodontal teeth, as it requires preparation along the roots. 2 The intention of the hybrid technique described in this article is to combine both of these procedures in order to obtain a less aggressive treatment with precise management of the soft tissue and an adequate esthetic outcome. The hybrid technique consists of enlarging the root portion of the teeth with composite resin to obtain a less aggressive tooth preparation, and thereafter placing porcelain veneers.

  15. Universal dimer in a collisionally opaque medium: experimental observables and Efimov resonances.

    Science.gov (United States)

    Machtey, Olga; Kessler, David A; Khaykovich, Lev

    2012-03-30

    A universal dimer is subject to secondary collisions with atoms when formed in a cloud of ultracold atoms via three-body recombination. We show that in a collisionally opaque medium, the value of the scattering length that results in the maximum number of secondary collisions may not correspond to the Efimov resonance at the atom-dimer threshold and thus cannot be automatically associated with it. This result explains a number of controversies in recent experimental results on universal three-body states and supports the emerging evidence for the significant finite range corrections to the first excited Efimov energy level.

  16. Accurate bulk density determination of irregularly shaped translucent and opaque aerogels

    Science.gov (United States)

    Petkov, M. P.; Jones, S. M.

    2016-05-01

    We present a volumetric method for accurate determination of bulk density of aerogels, calculated from extrapolated weight of the dry pure solid and volume estimates based on the Archimedes' principle of volume displacement, using packed 100 μm-sized monodispersed glass spheres as a "quasi-fluid" media. Hard particle packing theory is invoked to demonstrate the reproducibility of the apparent density of the quasi-fluid. Accuracy rivaling that of the refractive index method is demonstrated for both translucent and opaque aerogels with different absorptive properties, as well as for aerogels with regular and irregular shapes.

  17. Treating Opaque Beer Wastewater Using a Novel Internal Circulation Membrane Bioreactor

    Institute of Scientific and Technical Information of China (English)

    TAN Xin; REN Yanshuang; ZHAO Lin

    2006-01-01

    An innovative internal circulation membrane bioreactor( ICMBR)treating traditional opaque beer brewery wastewater was introduced. Beer wastewater from Tianjin Huarun Brewhouse wastaken as the influent. The removal efficiency of suspended solid, chemical oxygen demand, total nitrogen and ammonia nitrogen were studied with the changeable hard real time design method, organic loading rate and nutrition elements. The average percentage reduction in chemical oxygen demand achieved 90%. The total nitrogen and ammonia nitrogen were also reduced by 90% and 95%,respectively. The results indicate that the outlet of ICMBR meets the requirements of the environment landscape recycling use.

  18. Chemical compositions of siderophile element-rich opaque assemblages in an Allende inclusion

    Science.gov (United States)

    Sylvester, Paul J.; Ward, Brian J.; Grossman, Lawrence; Hutcheon, Ian D.

    1990-01-01

    Chemical compositions of ten opaque assemblages, or Fremdlinge, from an Allende Type B Ca-,Al-rich coarse-grained inclusion were determined. Attempts to model the abundances of refractory siderophiles assuming condensation from the solar nebula into a single phase failed to match the observed combination of subchondritic Re/Os and Ir/Pt ratios. However, virtually all refractory siderophile fractionations in these Fremdlinge could be matched by a different model, in which all metals condensed into three separate alloys according to their crystal structures.

  19. Effect of Provisional Cements on Shear Bond Strength of Porcelain Laminate Veneers

    OpenAIRE

    Altintas, Subutay Han; Tak, Onjen; Secilmis, Asli; Usumez, Aslihan

    2011-01-01

    Objectives: The purpose of this study was to evaluate the effect of three provisional cements and two cleaning techniques on the final bond strength of porcelain laminate veneers. Methods: The occlusal third of the crowns of forty molar teeth were sectioned and embedded in autopolymerizing acrylic resin. Dentin surfaces were polished and specimens were randomly divided into four groups (n=10). Provisional restorations were fabricated and two provisional restorations were cemented onto each to...

  20. The Shear Bond Strength of Porcelain Laminate to Prepared and Unprepared Anterior Teeth

    Directory of Open Access Journals (Sweden)

    Ali Asghar Alavi

    2017-03-01

    Full Text Available Statement of the Problem: Porcelain laminate veneer is an esthetic restoration used as an alternative to full veneer crowns and requires minimal tooth preparation. In restoration with porcelain laminate veneers, both the longevity of the laminate and conservation of the sound tooth structure are imperative. Purpose: The present study aimed to investigate the shear bond strength of porcelain laminates to prepared- and unprepared- anterior teeth in order to compare their longevity and success rate. Materials and Method: Thirty extracted maxillary central incisors were randomly divided into 3 groups regarding their preparation methods. The preparation methods were full-preparation in group A, full-preparation and finishing with fine diamond bur in group B, and no-preparation, only grinding with diamond bur in group C. After conditioning the teeth, ceramic veneers (IP S e.max were silanated and then cemented with DuoLink luting cement. The shear bond strength was measured for each group and failure mode was determined by stereomicroscopic examination. Results: Group C exhibited the highest shear bond strength. The shear bond strength was significantly different between groups C and B (p 0.05. Adhesion failure mode was found to be more common than the cohesive mode. Conclusion: Regarding the shear bond strength of unprepared anterior teeth to porcelain laminate veneers yielded by this study, no-preparation veneers might be used when the enamel is affected by wearing, trauma, or abrasion. It can also be used in patients who refuse the treatments which involve tooth reduction and preparation.

  1. Microscale resolution fracture toughness profiling at the zirconia-porcelain interface in dental prostheses

    Science.gov (United States)

    Lunt, Alexander J. G.; Mohanty, Gaurav; Neo, Tee K.; Michler, Johann; Korsunsky, Alexander M.

    2015-12-01

    The high failure rate of the Yttria Partially Stabilized Zirconia (YPSZ)-porcelain interface in dental prostheses is influenced by the micro-scale mechanical property variation in this region. To improve the understanding of this behavior, micro-scale fracture toughness profiling by nanoindentation micropillar splitting is reported for the first time. Sixty 5 μm diameter micropillars were machined within the first 100 μm of the interface. Berkovich nanoindentation provided estimates of the bulk fracture toughness of YPSZ and porcelain that matched the literature values closely. However, the large included tip angle prevented precise alignment of indenter with the pillar center. Cube corner indentation was performed on the remainder of the pillars and calibration between nanoindentation using different tip shapes was used to determine the associated conversion factors. YPSZ micropillars failed by gradual crack propagation and bulk values persisted to within 15 μm from the interface, beyond which scatter increased and a 10% increase in fracture toughness was observed that may be associated with grain size variation at this location. Micropillars straddling the interface displayed preferential fracture within porcelain parallel to the interface at a location where nano-voiding has previously been observed and reported. Pure porcelain micropillars exhibited highly brittle failure and a large reduction of fracture toughness (by up to ~90%) within the first 50 μm of the interface. These new insights constitute a major advance in understanding the structure-property relationship of this important bi-material interface at the micro-scale, and will improve micromechanical modelling needed to optimize current manufacturing routes and reduce failure.

  2. Two-body wear of dental porcelain and substructure oxide ceramics.

    Science.gov (United States)

    Rosentritt, Martin; Preis, Verena; Behr, Michael; Hahnel, Sebastian; Handel, Gerhard; Kolbeck, Carola

    2012-06-01

    The aim of this in vitro study was to investigate the two-body wear of different ceramics. Two-body wear tests were performed in a chewing simulator with steatite and enamel antagonists, respectively. Specimens were loaded in a pin-on-block design with a vertical load of 50 N for 1.2 × 10(5) cycles; (f = 1.6 Hz; lateral movement, 1 mm; mouth opening: 2 mm). Human enamel was used as a reference. Three zirconia ceramics, three veneering porcelains, two glass-infiltrated and one lithium disilicate ceramic were investigated. Veneering and lithium disilicate ceramics were glazed before testing. Surface roughness Ra (SP6, Perthen-Feinprüf, G) and wear depth were determined using a 3D scanner (Laserscan 3D, Willytec, G). SEM (Quanta FEG 400, FEI, USA) pictures of the worn specimens and antagonists were made for evaluating wear performance. Veneering porcelain provided wear traces between 71.2 and 124.1 μm (enamel antagonist) and 117.4 and 274.1 μm (steatite). Wear of the steatite antagonists varied between 0.618 and 2.85 mm². No wear was found for zirconia and glass-infiltrated substructure ceramics. Also, no wear was found for the corresponding antagonists. Wear of specimens and antagonists was strongly material dependent. No visible wear was found on zirconia and glass-infiltrated ceramics. Porcelain and lithium disilicate ceramic showed a comparable or lower wear than the enamel reference. Antagonist wear was found to be lower when specimens were made of substructure oxide ceramics instead of veneering porcelain. From the point of wear testing, zirconia may be used for the fabrication of fixed dental prosthesis without veneering.

  3. The Shear Bond Strength of Porcelain Laminate to Prepared and Unprepared Anterior Teeth

    Science.gov (United States)

    Alavi, Ali Asghar; Behroozi, Zeinab; Nik Eghbal, Farid

    2017-01-01

    Statement of the Problem: Porcelain laminate veneer is an esthetic restoration used as an alternative to full veneer crowns and requires minimal tooth preparation. In restoration with porcelain laminate veneers, both the longevity of the laminate and conservation of the sound tooth structure are imperative. Purpose: The present study aimed to investigate the shear bond strength of porcelain laminates to prepared- and unprepared- anterior teeth in order to compare their longevity and success rate. Materials and Method: Thirty extracted maxillary central incisors were randomly divided into 3 groups regarding their preparation methods. The preparation methods were full-preparation in group A, full-preparation and finishing with fine diamond bur in group B, and no-preparation, only grinding with diamond bur in group C. After conditioning the teeth, ceramic veneers (IP S e.max) were silanated and then cemented with DuoLink luting cement. The shear bond strength was measured for each group and failure mode was determined by stereomicroscopic examination. Results: Group C exhibited the highest shear bond strength. The shear bond strength was significantly different between groups C and B (p 0.05). Adhesion failure mode was found to be more common than the cohesive mode. Conclusion: Regarding the shear bond strength of unprepared anterior teeth to porcelain laminate veneers yielded by this study, no-preparation veneers might be used when the enamel is affected by wearing, trauma, or abrasion. It can also be used in patients who refuse the treatments which involve tooth reduction and preparation. PMID:28280760

  4. Multidisciplinary full-mouth restoration with porcelain veneers and laboratory-fabricated resin inlays.

    Science.gov (United States)

    Narcisi, E M; DiPerna, J A

    1999-08-01

    Recent advances in dental materials, laboratory technology, and adhesive protocols have significantly expanded the contemporary restorative armamentarium. Utilized in combination with comprehensive treatment planning, these innovations enable clinicians to provide enhanced aesthetic care that achieves the increasing expectations of their patients. Using a detailed case presentation, this article highlights the harmonious integration of modern smile design, material selection, and interdisciplinary communication that must be addressed in order to deliver optimal treatment with porcelain laminate veneer and laboratory-fabricated resin inlay restorations.

  5. Esthetic Rehabilitation of the Smile with No-Prep Porcelain Laminates and Partial Veneers

    OpenAIRE

    Arcelino Farias-Neto; Edna Maria da Cunha Ferreira Gomes; Alfonso Sánchez-Ayala; Alejandro Sánchez-Ayala; Larissa Soares Reis Vilanova

    2015-01-01

    Rehabilitation of patients with anterior conoid teeth may present a challenge for the clinician, especially when trying to mimic the nature with composite resins. This clinical report exemplifies how a patient with conoid upper lateral incisors was rehabilitated with minimally invasive adhesive restorations. Following diagnostic wax-up and cosmetic mock-up, no-prep veneers and ceramic fragments (partial veneers) were constructed with feldspathic porcelain. This restorative material presents e...

  6. Evaluation of low-fusing porcelain bonded to dental cast Ti-Zr alloys

    Energy Technology Data Exchange (ETDEWEB)

    Ho, W.-F. [Department of Materials Science and Engineering, Da-Yeh University, Taiwan (China); Cheng, C.-H. [Prosthetic Division of Taichung Veterans General Hospital, Taiwan (China); Chen, W.-K. [Department of Mechanical and Automation Engineering, Da-Yeh University, Taiwan (China); Wu, S.-C. [Department of Dental Laboratory Technology, Central Taiwan University of Science and Technology, Taiwan (China); Institute of Biomedical Engineering and Material Science, Central Taiwan University of Science and Technology, Taiwan (China); Lin, H.-C. [Department of Dental Laboratory Technology, Central Taiwan University of Science and Technology, Taiwan (China); Hsu, H.-C. [Department of Dental Laboratory Technology, Central Taiwan University of Science and Technology, Taiwan (China); Institute of Biomedical Engineering and Material Science, Central Taiwan University of Science and Technology, Taiwan (China)], E-mail: hchsu@ctust.edu.tw

    2009-03-05

    This study was designed to evaluate the bonding characteristics of titanium porcelain Duceratin bonded to Ti-Zr alloys and commercially pure titanium (c.p. Ti). In addition, the thermal expansion coefficient (CTE) of all Ti-Zr alloys and c.p. Ti was also evaluated. The experimental metals used for this study include c.p. Ti, Ti-10Zr, Ti-20Zr, Ti-30Zr and Ti-40Zr alloys (in wt.%). Experimental results indicated that Ti-10Zr alloy had the highest bond strength and higher than that of c.p. Ti (21.1 MPa). When the Zr content was increased to 20 wt.% or higher, the strengths were below the lower limit value in the DIN 13.927 standard (25 MPa). In addition, the CTE values of the Ti-Zr alloys were lower than that of c.p. Ti (10.1 x 10{sup -6} deg. C{sup -1}), and ranged from 9.9 to 9.4 x 10{sup -6} deg. C{sup -1}. The CTE values had a tendency to decrease as the zirconium content increased. On the other hand, CTEs for Ti-30Zr and Ti-40Zr were below that of Duceratin, and thus, the surfaces of the Ti-30Zr and Ti-40Zr alloy specimens on which the porcelain was fired were seen to curve slightly toward the porcelain side upon cooling. It was concluded that the high bond strength of Ti-10Zr alloy was the result of the low difference in the CTE between this alloy and Duceratin porcelain, which would verify the fact that weak bond strength is the result of a mismatch between CTEs.

  7. Radiological impact assessment to the environment due to waste from disposal of porcelain.

    Science.gov (United States)

    Morsi, Tarek; Hegazy, Rehab; Badawy, Wael

    2017-06-01

    The present study aimed to assess the radiological parameters from gamma rays due to the uncontrolled disposal of porcelain waste to the environment. Qualitative and quantitative identification of radionuclides in the investigated samples was carried out by means of a high-purity germanium (HPGe) detector. The average activity concentrations of the local porcelain samples were measured as 208.28 Bq/kg for (226)Ra, 125.73 Bq/kg for (238)U, 84.94 Bq/kg for (232)Th and 1033.61 Bq/kg for (40)K, respectively. The imported samples had an average activity of 240.57 Bq/kg for (226)Ra, 135.56 Bq/kg for (238)U, 115.74 Bq/kg for (232)Th and 1312.49 Bq/kg for (40)K, respectively. Radiological parameters and the radium equivalent Raeq for the investigated samples were calculated. The external and internal hazard indices, representative level index (Iγ), alpha index (Iα), and the exemption level (Ix), were estimated to be higher than the recommended value (unity), while the average activity concentrations for the studied samples were higher than recommended levels. In conclusion, we are concerned that disposal of porcelain in the environment might be a significant hazard.

  8. Influence of residual stresses on the cutting behavior of porcelain stoneware tiles

    Energy Technology Data Exchange (ETDEWEB)

    Gonzaga Gomes Delavi, D.; Garcia-Ten, J.; Saburit, A.; Escrig, A.; Nonic, A. de; Hotza, D.

    2016-07-01

    This study was undertaken to examine the influence of residual stresses on porcelain tile behaviour under cutting. To do so, two samples of glazed industrial porcelain tiles that exhibited different behaviour under cutting were selected. Using these industrial tiles, cutting tests were performed and the macroscopic residual stresses were determined by the strain relaxation incremental slotting method. The influence of the cooling rate on the arising residual stresses and their effect on tile cutting were also studied. For the porcelain tile with appropriate cutting behaviour, the residual stress profile in the body was symmetrical and could be fitted by just using the second- degree Legendre polynomial. This was the expected behaviour for homogenously cooled ceramic materials (same cooling rate at the proper surface as at the rib). For pieces with inappropriate cutting behaviour, it was necessary to use more terms of the series, which suggested that cooling had not been homogeneous. With regard to the influence of cooling, the temperature range in which residual stresses were generated was determined and it was verified that pieces with a greater level of stresses exhibited worse cutting behaviour. (Author)

  9. Effect of grinding and fluoride-gel exposure on strength of ion-exchanged porcelain.

    Science.gov (United States)

    Anusavice, K J; Hojjatie, B; Chang, T C

    1994-08-01

    Strengthening of dental porcelain through a diffusion heat treatment at 450 degrees C of a potassium-enriched, ion-exchange surface coating has been demonstrated in several recent studies. However, little attention has been focused on the potential strength reduction of these materials when the treated surfaces are ground or etched under clinically simulated conditions. The objective of this study was to test the hypothesis that partial removal of the surface layers of ion-exchanged porcelains by grinding or exposure to acidulated fluoride gel will significantly reduce their flexure strength. Nine groups of body porcelain disks were ion-exchanged at 450 degrees C for 30 min. One of these groups was subjected to ion exchange and no further surface treatment. Eight specimen groups were subjected to the following procedures after ion exchange: grinding to depths of 50 microns, 100 microns, 150 microns, 200 microns, and 250 microns, and exposure to acidulated fluoride for 30 min, 60 min, and 300 min. A tenth group (FC) was fired at 960 degrees C and fast-cooled in air, but the disks were not subjected to the ion-exchange treatment. Surface stress was calculated from measured values of cracks induced in the treated surfaces. Fluoride exposure for up to 60 min resulted in a significant decrease in surface compression (P 0.05).

  10. [Cr-Ti-Al-N complex coating on titanium to strengthen Ti/porcelain bonding].

    Science.gov (United States)

    Zhang, Hui; Guo, Tian-wen; Li, Jun-ming; Pan, Jing-guang; Dang, Yong-gang; Tong, Yu

    2006-02-01

    To study the feasibility of magnetron sputtering Cr-Ti-Al-N complex coating as an interlayer on titanium to enhance the titanium-ceramic binding strength. With a three-point bending test according to ISO 9693, the binding strength of Duceratin (Degussa) to titanium substrate prepared with 4 different surface treatments (polishing, polishing and megnetron sputtering Cr, Ti, Al, and N complex coating, sandblasting, sandblasting and coating) was evaluated. Ti/porcelain interface and fractured Ti surface were examined using scanning electron microscopy with energy-dispersive spectrometry (EDS). The binding strength of polished and coated titanium/Duceratin was significantly higher than polished titanium group (Pcoated titanium/Duceratin did not differ significantly from that of sandblasted titanium group (P>0.05), and the strength in the two sandblasted titanium groups was significantly higher than that in polished and coated titanium group (PCr-Ti-Al-N complex on polished titanium can increase the titanium/porcelain binding strength. Megnetron sputtering coating is a promising Ti/porcelain interlayer.

  11. Intraoral treatment of veneering porcelain chipping of fixed dental restorations: a review and clinical application.

    Science.gov (United States)

    Kimmich, Magdalena; Stappert, Christian F J

    2013-01-01

    Every dental ceramic system can experience failure of the veneering porcelain. However, the increasing popularity of all-ceramic crowns and fixed dental prostheses (FDPs) seems to have led to an increasing need to repair chipped veneering porcelain. The authors compared different methods to repair fractured ceramic restorations (porcelain-fused-to-metal and all-ceramic) and explain the basic principles of adhesion in these systems. They also evaluated the frequency and causes of failure in dental ceramic systems. This review is based on the results of PubMed and Google Scholar searches, as well as on a hand search of the scientific literature, resulting in 300 articles from 1977 to 2012. The authors used multiple key words (ceramic, repair, bonding, hydrofluoric acid, air abrasion, silane, phosphates, silicon dioxide) and different strategies (connecting different key words with OR, NOR and AND and truncation of the stem of words) to search the databases. Because of differences in the material composition of ceramic systems (composed of metal, alumina or zirconia, glass-ceramics and feldspathic ceramics), different treatments are required for the exposed material surfaces after chipping. Use of hydrofluoric acid etching, air abrasion, tribochemical coating, silanization and metal primers or zirconia primers seem to be the most successful conditioning methods for durable bonding and repair. Intraoral repair of a restoration offers a satisfying option for the patient when the restoration cannot be removed or replaced. Its success depends largely on the conditioning methods used for the fractured surfaces.

  12. TECHNOLOGICAL TESTS USING QUARTZITE RESIDUES AS COMPONENT OF CERAMIC MASS AT THE PORCELAIN STONEWARE PRODUCTION

    Directory of Open Access Journals (Sweden)

    Marcondes Mendes Souza

    2015-03-01

    Full Text Available This work aims to evaluate through technological tests the use of quartzite residues as component at the the production of porcelain stoneware. Were collected five samples of quartzites called of green quartzite, black quartzite, pink quartzite, goldy quartzite, white quartzite. After, the raw materials were milled, passed by a sieve with a Mesh of 200# (Mesh and characterized by chemical analysis in fluorescence of x-rays and also analysis of the crystalline phases by diffraction of x-rays. The porcelain tiles mass is composed of five formulations containing 57% of feldspar, 37% of clay and 6% of residues of quartzite with different coloration. For the preparation of the specimens, it was used uniaxial pressing, which afterwards were synthesized at 1150°C, 1200°C and 1250°C. After the sintering, the specimens were submit for tests of technological characterization like: water absorption, linear shrinkage, apparently porosity, density and flexural strain at three points. The results presented in the fluorescence of x-rays showed a high-content of iron oxide on black quartzite that is why it was discarded the utilization of it in porcelain stoneware. All quartzite formulations had low water absorption achieved when synthesized at 1200°C, getting 0.1 to 0.36% without having gone through the atomization process. At the tests of flexural strain, all the quartzite had in acceptance limits, according to the European norm EN 100, overcoming 27 MPA at 1200°C

  13. Effect of resin and type of surface treatment on the flexural strength of cracked feldspathic porcelain

    Directory of Open Access Journals (Sweden)

    Kermanshah Hamid

    2015-05-01

    Full Text Available Background and Aims: Porcelain restorations are often ground for clinical adjustment and this removes the surface glaze layer and introduces flaws that can grow in wet environments due to stress-corrosion, reduce the strength of porcelain and limit restoration lifetime. The aim of this study was to introduce some surface treatment methods to control the flaws of ceramic restorations external surface and improve their strength.   Materials and Methods: 40 feldspathic discs were prepared and divided into 4 groups (n=10: not indented (group 1 and others indented by vickers with 29.4 N and received different treatments: no treatment (group 2, polished (group 3 and polished-silane-resin (group 4. Biaxial flexural strength of discs was tested after water storage. Data were analyzed using one-way ANOVA .   Results: The mean flexural strength of specimens in group 1 (134.49±12.60, 2 (94.81±15.41, 3 (89.20±16.22 and 4 (80.67±12.01 were measured. Group 1 (not indented revealed significantly higher strength (P<0.001 than that of indented groups (2, 3 and 4 . There was no significant difference between group 2 (no treatment and 3 or 4 (treated and between treatment methods (3 and 4 (P=0.136.   Conclusion: The strength of porcelains is dependent on presence of cracks. With the limitations of this study, none of the treatment methods could strengthen the cracked ceramic.

  14. Esthetic rehabilitation of worn anterior teeth with thin porcelain laminate veneers.

    Science.gov (United States)

    Gresnigt, Marco; Ozcan, Mutlu; Kalk, Warner

    2011-01-01

    Bonded porcelain restorations are a predictable and durable treatment option with which not only esthetic appearance but also the strength and function of teeth can be re-established. One of the most important issues of today's dentistry is the preservation of sound enamel. Following biomimetic principles, employing minimally invasive applications and adhesive technologies are of paramount importance for successful restorations. The mock-up technique is advised for delicate removal of the required space for thin porcelain veneers minimally. Besides minimally invasive preparation, long-term success is determined by the adhesive quality of the laminate veneers. This case presentation demonstrates restoration of anterior dentition where the wear of incisal edges posed a negative effect on the smile of the patient. Before bonded porcelain veneers were adhesively cemented, incisal lengthening with direct resin composite and gingival contouring was performed. By using the mock-up technique, minimal preparations were made with the outline ending in enamel only. For cementation of these restorations, step-by-step adhesive procedures are presented.

  15. Evolution of microstructure in flyash-containing porcelain body on heating at different temperatures

    Indian Academy of Sciences (India)

    Kausik Dana; Swapan Kumar Das

    2004-04-01

    15 wt% flyash (a calcined byproduct of thermal power plant) was incorporated in a normal triaxial kaolin–quartz–feldspar system by replacing equivalent amount of quartz. The differences in microstructural evolution on heating the compact mass of both normal and flyash-containing porcelain at different temperatures (1150–1300°C) were examined using scanning electron microscopy (SEM) operating in secondary electron image (SEI) mode. Microstructure of normal porcelain did not show the presence of mullite and quartz grains at 1200°C and the viscosity of silica-rich glass restricted the growth of mullite crystals at 1250°C. Flyash porcelain, on the other hand, shows the presence of primary mullite aggregates in the clay relict and a significant growth of mullite crystals in a low viscosity glassy matrix at 1200°C itself. At 1300°C, both the bodies show a larger region of more elongated (> 1 m) secondary mullite along with clusters of smaller sized primary mullite (< 1 m). Small primary mullite crystals in the clay relict can be distinguished from elongated secondary mullite crystals in the feldspar relict in their size. Primary mullite aggregates remain stable also at higher temperatures. XRD studies were carried out for quantitative estimation of quartz, mullite and glass, which supported the SEM observations. An attempt was also made to correlate their mechanical strength with the constituent phases.

  16. Influence of the processing route of porcelain/Ti-6Al-4V interfaces on shear bond strength.

    Science.gov (United States)

    Toptan, Fatih; Alves, Alexandra C; Henriques, Bruno; Souza, Júlio C M; Coelho, Rui; Silva, Filipe S; Rocha, Luís A; Ariza, Edith

    2013-04-01

    This study aims at evaluating the two-fold effect of initial surface conditions and dental porcelain-to-Ti-6Al-4V alloy joining processing route on the shear bond strength. Porcelain-to-Ti-6Al-4V samples were processed by conventional furnace firing (porcelain-fused-to-metal) and hot pressing. Prior to the processing, Ti-6Al-4V cylinders were prepared by three different surface treatments: polishing, alumina or silica blasting. Within the firing process, polished and alumina blasted samples were subjected to two different cooling rates: air cooling and a slower cooling rate (65°C/min). Metal/porcelain bond strength was evaluated by shear bond test. The data were analyzed using one-way ANOVA followed by Tuckey's test (pporcelain-to-Ti-6Al-4V alloy interfaces ranged from 27.1±8.9MPa for porcelain fused to polished samples up to 134.0±43.4MPa for porcelain fused to alumina blasted samples. According to the statistical analysis, no significant difference were found on the shear bond strength values for different cooling rates. Processing method was statistically significant only for the polished samples, and airborne particle abrasion was statistically significant only for the fired samples. The type of the blasting material did not cause a statistically significant difference on the shear bond strength values. Shear bond strength of dental porcelain to Ti-6Al-4V alloys can be significantly improved from controlled conditions of surface treatments and processing methods.

  17. Evaluation of mineral kaolinite present in portuguese clays for use in porcelain stoneware; Avaliacao do mineral caulinita presente em argilas portuguesas para uso em gres porcelanato

    Energy Technology Data Exchange (ETDEWEB)

    Luna da Silveira, G.C. [Instituto Federal do Rio Grande do Norte (IFRN), RN (Brazil); Acchar, W.; Gomes, U.U.; Luna da Silveira, R.V. [Universidade Federal do Rio Grnde do Norte (UFRN), RN (Brazil); Labrincha, A.; Miranda, C.M.P., E-mail: glebacoelli@hotmail.com [Universidade de Aveiro (Portugal)

    2016-07-01

    Kaolinite is a mineral from the kaolin, product resulting from transformation in depth of alumino silicate mineral type, such as feldspars, plagioclase and feldspars contained in the rocks. Clays are raw materials that have as main characteristic the plasticity property, which gives the product, after applying a certain pressure, a defined shape and an increase in the mechanical resistance when they become from green to dry and then to sintered. Given these characteristics, this paper analyzes the presence of the existing mineral kaolinite in two portuguese clays who are used in the preparation of formulations of porcelain stoneware tiles. The analyzes of the two clays were made by fluorescence x-ray diffraction of x-rays, thermal analysis, particle size and scanning electron microscopy, to better use of this mineral in the formulations. In both clays were found aluminum oxide, as well as mineral quartz, kaolinite and illite. (author)

  18. Effect of experimental parameters on optimal reflection of light from opaque media

    Science.gov (United States)

    Anderson, Benjamin R.; Gunawidjaja, Ray; Eilers, Hergen

    2016-01-01

    Previously we considered the effect of experimental parameters on optimized transmission through opaque media using spatial light modulator (SLM)-based wavefront shaping. In this study we consider the opposite geometry, in which we optimize reflection from an opaque surface such that the backscattered light is focused onto a spot on an imaging detector. By systematically varying different experimental parameters (genetic algorithm iterations, bin size, SLM active area, target area, spot size, and sample angle with respect to the optical axis) and optimizing the reflected light we determine how each parameter affects the intensity enhancement. We find that the effects of the experimental parameters on the enhancement are similar to those measured for a transmissive geometry, but with the exact functional forms changed due to the different geometry and the use of a genetic algorithm instead of an iterative algorithm. Additionally, we find preliminary evidence of greater enhancements than predicted by random matrix theory, suggesting a possibly new physical mechanism to be investigated in future work.

  19. Anisotropic optical response of optically opaque elastomers with conductive fillers as revealed by terahertz polarization spectroscopy

    Science.gov (United States)

    Okano, Makoto; Watanabe, Shinichi

    2016-12-01

    Elastomers are one of the most important materials in modern society because of the inherent viscoelastic properties due to their cross-linked polymer chains. Their vibration-absorbing and adhesive properties are especially useful and thus utilized in various applications, for example, tires in automobiles and bicycles, seismic dampers in buildings, and seals in a space shuttle. Thus, the nondestructive inspection of their internal states such as the internal deformation is essential in safety. Generally, industrial elastomers include various kinds of additives, such as carbon blacks for reinforcing them. The additives make most of them opaque in a wide spectral range from visible to mid-infrared, resulting in that the nondestructive inspection of the internal deformation is quite difficult. Here, we demonstrate transmission terahertz polarization spectroscopy as a powerful technique for investigating the internal optical anisotropy in optically opaque elastomers with conductive additives, which are transparent only in the terahertz frequency region. The internal deformation can be probed through the polarization changes inside the material due to the anisotropic dielectric response of the conductive additives. Our study about the polarization-dependent terahertz response of elastomers with conductive additives provides novel knowledge for in situ, nondestructive evaluation of their internal deformation.

  20. Coherent lattice dynamics in opaque crystals: Testing the adequacy of two-tensor model

    Science.gov (United States)

    Misochko, O. V.; Lebedev, M. V.

    2016-11-01

    We report the ultrafast pump-probe study of B i2T e3 , Sb, Bi, and Te aimed to check the two-tensor model predictions for the creation of lattice coherence. The dependence of coherent ultrafast response on phonon frequency was measured for topological insulator B i2T e3 , the spectrum of which possesses two fully symmetric phonons. The effect of the pump pulse duration and power on the magnitude of coherent amplitude was evaluated in the model opaque crystals, such as two semimetals, bismuth and antimony, and semiconducting tellurium. In our analysis of the pump-probe data, we separated the transient total reflectivity into the sum of two contributions: one due to the photogenerated carriers and the second due to the coherent phonons. All fully symmetric phonons exhibit a cosinelike dependence and grow linearly with increasing average pump power provided the pulse duration remains unchanged. Varying the pump pulse duration, we observed a monotonic decrease of coherent amplitude for longer pulses, whereas the electronic contribution was almost unchanged. This lack of the correlation between the carriers and the coherent amplitude was further supported by coherent control experiments on Te. Based on the comparison of theoretical predictions with experimental observations, we conjecture that the lattice coherence creation in opaque crystals can be linked to a Raman-like process.

  1. Detection of static and dynamic objects in nontransparent media and opaque water

    Science.gov (United States)

    Ginzburg, Vera M.

    1998-09-01

    Holographic methods for observation of stationary and moving objects located behind a non-transparent screen, inside nontransparent construction or in opaque (turbulent) water are discussed. In the first, case, microwave holography is used. In particular, a stationary microwave facility or a holographic video camera with a picture frequency of 20 Hz is used. Defects inside various large concrete construction elements and protection lids were found. An image of a live dog behind a non-transparent wall was recorded. In the second case, ultrasound radiation was used. In particular, water surface disturbances caused by the radiation pressure of ultrasound waves passing across underwater objects were recorded. Two methods were created; one based on the effects of refraction and diffraction of a laser beam by water surface disturbances, and another based on the Talbot effect. It is shown that the first method can be used for detection of dynamic underwater objects crossing the sound beam. The Talbot effect method permits, besides detection, formation of images of these objects. Examples are shown of detection of live fish in opaque water and formation of images of small (approximately 1.5 cm2) motionless objects.

  2. Relation between the microstructure and technological properties of porcelain stoneware. A review

    Directory of Open Access Journals (Sweden)

    Romero, M.

    2015-12-01

    Full Text Available Porcelain stoneware is a strongly sintered ceramic material fabricated from ball clays-quartz-feldspar mixtures. Porcelain stoneware is characterized by its excellent technical and functional properties (low water absorption, high mechanical properties, resistant to chemical substances and cleaning agents, aesthetic possibilities …. These characteristic and technical features make that among the different types of ceramic tile, porcelain stoneware is the ceramic product that in the last years has best withstood the economic crisis in the construction sector. These properties are related to the microstructure of porcelain stoneware, which is a grain and bond type with large particles of filler (quartz, mullite crystals, a silica-rich amorphous phase and porosity. The understanding of the relationship between the microstructure and the properties of porcelain stoneware is hardly important for the development and design of these materials whose tendency is the manufacture of thinner tiles with higher dimensions but must continue to comply the specific technical requirements.El gres porcelánico es un material sinterizado fabricado a partir de una mezcla de arcillas, cuarzo y feldespato. Tecnológicamente, el gres porcelánico se caracteriza por sus excelentes características técnicas y funcionales (baja absorción de agua, buenas propiedades mecánicas, resistente a substancias químicas, posibilidades estéticas…. Estas cualidades han propiciado que, entre los diferentes tipos de baldosa cerámica, es el gres porcelánico el producto que mejor ha resistido la crisis económica sufrida por el Sector de la Construcción. Las propiedades tecnológicas están relacionadas con su microestructura, compuesta de partículas de cuarzo, cristales de mullita, fase amorfa y porosidad. El conocimiento de la relación entre la microestructura y las propiedades tecnológicas del gres porcelánico es de gran importancia para avanzar en el diseño y

  3. The effect of porcelain firing and type of finish line on the marginal fit of zirconia copings.

    Science.gov (United States)

    Vojdani, Mahroo; Safari, Anahita; Mohaghegh, Mina; Pardis, Soheil; Mahdavi, Farideh

    2015-06-01

    Although all-ceramic restorations are broadly used, there is a lack of information concerning how their fit is affected by fabrication procedure and marginal configuration. The purpose of this study was to evaluate the marginal fit of zirconia CAD/CAM ceramic crowns before and after porcelain firing. The influence of finish line configuration on the marginal fit was also evaluated. Twenty standardized zirconia CAD/CAM copings were fabricated for chamfer and shoulder finish line designs (n=10). The marginal fit of specimens was measured on 18 points, marked on the master metal die by using a digital microscope. After the crowns were finalized by porcelain veneering, the measurements of marginal fit were performed again. The means and standard deviations were calculated and data were analyzed using student's t-test and paired t-test (α=0.05). There were significant differences between marginal fit of chamfer and shoulder finish line groups before and after porcelain firing (p= 0.014 and p= 0.000, respectively). The marginal gap of copings with shoulder finish line was significantly smaller than those with chamfer configuration (p= 0.000), but there were no significant differences between the two marginal designs, after porcelain firing (p= 0.341). Porcelain veneering was found to have a statistically significant influence on the marginal fit of zirconia CAD/CAM crowns. Both margin configurations showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.

  4. Glazed porcelain tiles produced by the dry route: fluxing raw; Gres porcelanico esmaltado producido por via seca: materias primas fundentes

    Energy Technology Data Exchange (ETDEWEB)

    Melchiades, B. G.; Dos Santos, L. R.; Nastri, S.; Boschi, A. O.

    2012-07-01

    Fluxing agents are particularly important in porcelain tile compositions because this type of ceramic tile requires high volumes of vitreous phases during firing to eliminate open porosity. The volume and viscosity of the vitreous phases formed during firing control the densification process and thus determine the firing temperature and pyro plastic deformation. The fluxing agents commonly employed in porcelain tile compositions are feldspars, pettishly (used in Brazil) and nepheline. These raw materials are water-insoluble, which makes them particularly suitable for compositions of traditional porcelain tile produced by the wet route. However, a large group of water-soluble raw materials also have a good potential to act as fluxing agents and could be used in dry route processes. In this context, the purpose of this work was to determine the fluxing potential of water-soluble or partially water-soluble raw materials in a porcelain tile composition. The effectiveness of several borates, i.e., colemanite, ulexine, hydroboracite, as well as sodium carbonate, was tested in a comparative study. The results of this study indicate that small additions of these fluxing agents suffice to greatly reduce the firing temperature without causing high pyro plastic deformation of the bodies. The best results were obtained in compositions containing hydroboracite. This finding is especially relevant for the creation of alternative compositions of porcelain tiles produced by the dry route. Dry route processing is currently the focus of a great deal of interest due to environmental and economic issues. (Author)

  5. Effect of femtosecond laser treatment on the shear bond strength of a metal bracket to prepared porcelain surface.

    Science.gov (United States)

    Akpinar, Yusuf Ziya; Irgin, Celal; Yavuz, Tevfik; Aslan, Muhammed Ali; Kilic, Hamdi Sukur; Usumez, Aslihan

    2015-04-01

    The aim of this study was to investigate the effects of femtosecond laser treatment (Group FS) on the shear bond strength (SBS) of a metal bracket to prepared porcelain surface, and to compare it with other surface treatment techniques [50 μm Al2O3 sandblasting (Group SB), 9.6% hydrofluoric acid gel (Group HF), and neodymium-doped yttrium aluminium garnet (Nd:YAG laser) (Group NY)]. Because of the increasing number of adult patients in current orthodontic practice, achieving sufficient bond strength of composite resin to porcelain restorations without bond failure during the treatment is a challenge for orthodontists. In total, 80 glazed feldspathic porcelain samples were prepared and randomly assigned to four groups of 20. Treated surfaces were treated with a silane agent. Brackets were bonded to porcelain samples. The specimens were stored in distilled water for 24 h and then thermocycled for 500 cycles between 5° and 55°C. The SBS of the brackets was tested with a universal testing machine at a crosshead speed of 1 mm/min, until bonding failure occurred. The data were analyzed statistically using analysis of variance (ANOVA) and Tamhane multiple comparisons tests. The results of ANOVA indicated that the SBS values varied according to the surface treatment method (ptreatment produced high SBS of the processes assessed; therefore, it appears to be an effective method for bonding orthodontic metal brackets to prepared porcelain surfaces.

  6. Marginal Adaptation of Metal Ceramic Crowns Cast from Four Different Base Metal Alloys before and after Porcelain Application

    Directory of Open Access Journals (Sweden)

    Ali Hafezeqoran

    2015-04-01

    Material and Method: In this experimental study, a sound maxillary first premolar was prepared with chamfer and shoulder-bevel finish lines in palatal and buccal surfaces, respectively. Then the metal die was fabricated. Six points were marked 1 mm apical to the margin in the buccal and palatal surfaces. Forty impressions were taken from metal die by polyether impression material. Then, 10 frameworks were fabricated with each alloy type on stone dies. The vertical margin discrepancy between the frameworks and the marked points on metal dies were measured before and after porcelain firing. Paired sample t-test and One-way ANOVA, followed by multiple comparison tests (Tukey test were used to evaluate data. In this study, statistical significance was defined at p<0.05. Results: Before porcelain firing, T3 alloy showed the lowest marginal discrepancy on chamfer finish line (13.13 ± (1.26; but, the highest values were for Supermcast V copings and shoulder-bevel finish after porcelain application (30.83 ± (2.01. The mean marginal discrepancies of buccal and palatal surfaces before porcelain application were significantly lower for all alloy types (p<0.001. Conclusion:  The marginal adaptation of all four metal alloys was clinically acceptable and the thermal cycles of porcelain firing affected marginal adaptation.   Keywords: Crown; Marginal adaptation; Metal ceramic alloys

  7. Measurement of transient thickness between the body and graze layers of ancient porcelains using microprobe EDXRF technique

    Institute of Scientific and Technical Information of China (English)

    PENG Zi-Cheng; LEUNG P L; CHENG P K; LI M

    2004-01-01

    The oxide contents of TiO2, MnO, SrO and Fe2O3 in the body and graze layers of the Jiao-Tan-Xia (JTX) and Lao-Hu-Dong (LHD) porcelains in Southern Song Dynasty (1127-1279 A.D.) have been determined using an International Eagle-Ⅱμ-probe EDXRF spectrometer. The results show that the contents in the body are much different from those in the graze one. Therefore, the transient thickness (TT) between the body and graze layers can be measured through determination of a distance of the drift change in the chemical contents. The TT average for the JTX porcelains is 161μm, while that for the LHD porcelains is 258μm, which are consistent with a range of 0.15-0.3mm in the Ru-Yao porcelains. The different TT is related to the variances in firing temperature and raw material for manufacturing the respective porcelains.

  8. Effect of autoclave induced low-temperature degradation on the adhesion energy between yttria-stabilized zirconia veneered with porcelain.

    Science.gov (United States)

    Li, Kai Chun; Waddell, J Neil; Prior, David J; Ting, Stephanie; Girvan, Liz; van Vuuren, Ludwig Jansen; Swain, Michael V

    2013-11-01

    To investigate the effect of autoclave induced low-temperature degradation on the adhesion energy between yttria-stabilized zirconia veneered with porcelain. The strain energy release rate using a four-point bending stable fracture test was evaluated for two different porcelains [leucite containing (VM9) and glass (Zirox) porcelain] veneered to zirconia. Prior to veneering the zirconia had been subjected to 0 (control), 1, 5, 10 and 20 autoclave cycles. The specimens were manufactured to a total bi-layer dimension of 30 mm × 8 mm × 3 mm. Subsequent scanning electron microscopy/energy dispersive spectrometry, electron backscatter diffraction and X-ray diffraction analysis were performed to identify the phase transformation and fracture behavior. The strain energy release rate for debonding of the VM9 specimens were significantly higher (pautoclave cycles lowered the strain energy release rate significantly (pautoclave cycles between 5 and 20. The monoclinic phase reverted back to tetragonal phase after undergoing conventional porcelain firing cycles. EBSD data showed significant changes of the grain size distribution between the control and autoclaved specimen (cycle 20). Increasing autoclave cycles only significantly decreased the adhesion of the VM9 layered specimens. In addition, a conventional porcelain firing schedule completely reverted the monoclinic phase back to tetragonal. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. α-Pheromone-Induced “Shmooing” and Gene Regulation Require White-Opaque Switching during Candida albicans Mating

    OpenAIRE

    Lockhart, Shawn R.; Zhao, Rui; Daniels, Karla J.; Soll, David R.

    2003-01-01

    A 14-mer α-pheromone peptide of Candida albicans was chemically synthesized and used to analyze the role of white-opaque switching in the mating process. The α-pheromone peptide blocked cell multiplication and induced “shmooing” in a/a cells expressing the opaque-phase phenotype but not in a/a cells expressing the white-phase phenotype. The α-pheromone peptide induced these effects at 25°C but not at 37°C. An analysis of mating-associated gene expression revealed several categories of gene re...

  10. Formational history of lunar rocks - Applications of experimental geochemistry of the opaque minerals

    Science.gov (United States)

    Taylor, L. A.; Williams, K. L.

    1974-01-01

    Experimental data on the cooling histories of lunar rocks are presented along with a descriptive mineralogy of certain opaque minerals in Apollo 17 samples. Lunar rocks having Zr partitionings of coexisting ilmenite and ulvospinel indicative of high-temperature equilibrium (above 1000 C) appear to have cooled rapidly to temperatures below 800-900 C. The Ti content of troilite coexisting with ilmenite can be used to differentiate rock fragments which are mineralogically and texturally similar. It is found that Cr and Mg partitionings between coexisting armalcolite and ilmenite vary notably between rocks so that they can be used to distinguish otherwise similar samples. The spinels are analyzed as varieties of chromian ulvospinel and titanian chromite.

  11. An easy-to-use program for the determination of common opaque minerals

    Science.gov (United States)

    Glass, H. J.; Voncken, J. H. L.

    2010-12-01

    A Microsoft Excel macro is described that enables rapid recognition of common opaque minerals. The program uses ore mineralogical features such as reflectance, anisotropy, bireflectance, Vickers Hardness and morphological features (bladed crystals, zoning and twinning) to identify possible candidates from a database of 200 common ore minerals. Reflectance can be estimated from the uncorrected light of a microscope lamp. While the program yields all possible minerals matching the entered search criteria, these must be distinguished by additional information such as paragenesis, and detailed checks of observed features with data listed in reference works. The program is especially suited for students of ore microscopy and for mineralogists and petrologists who are not experts in ore microscopy.

  12. List context effects in languages with opaque and transparent orthographies: a challenge for models of reading

    Science.gov (United States)

    Traficante, Daniela; Burani, Cristina

    2014-01-01

    This paper offers a review of data which show that reading is a flexible and dynamic process and that readers can exert strategic control over it. Two main hypotheses on the control of reading processes have been suggested: the route de-emphasis hypothesis and the time-criterion hypothesis. According to the former, the presence of irregular words in the list might lead to an attenuation of the non-lexical process, while the presence of non-words could trigger a de-emphasis of the lexical route. An alternative account is proposed by the time-criterion hypothesis whereby the reader sets a flexible deadline to initiate the response. According to the latter view, it is the average pronunciation difficulty of the items in the block that modulates the time-criterion for response. However, it is worth noting that the list composition has been shown to exert different effects in transparent compared to opaque orthographies, as the consistency of spelling-sound correspondences can influence the processing costs of the non-lexical pathway. In transparent orthographies, the non-lexical route is not resource demanding and can successfully contribute to the pronunciation of regular words, thus its de-emphasis could not be as useful/necessary as in opaque orthographies. The complex patterns of results from the literature on list context effects are a challenge for computational models of reading which face the problem of simulating strategic control over reading processes. Different proposals suggest a modification of parameter setting in the non-lexical route or the implementation of a new module aimed at focusing attention on the output of the more convenient pathway. Simulation data and an assessment of the models’ fit to the behavioral results are presented and discussed to shed light on the role of the cognitive system when reading aloud. PMID:25309485

  13. Introgression of opaque2 into Waxy Maize Causes Extensive Biochemical and Proteomic Changes in Endosperm.

    Directory of Open Access Journals (Sweden)

    Zhiqiang Zhou

    Full Text Available Waxy maize is prevalently grown in China and other countries due to the excellent characters and economic value. However, its low content of lysine can't meet the nutritional requirements of humans and livestock. In the present study, we introgressed the opaque2 (o2 allele into waxy maize line Zhao OP-6/O2O2 by using marker-assisted selection (MAS technique and successfully improved the lysine content and quality of waxy maize. Transcript abundance analysis indicated that the wx1 expression levels had no difference between Zhao OP-6/o2o2 and Zhao OP-6/O2O2. However, Zhao OP-6/o2o2 was characterized by a phenotype of hard and vitreous kernels and accumulation of protein bodies at smaller size (one third of that of parents but in larger numbers. Biochemical analyses showed that Zhao OP-6/o2o2 had 16.7% less free amino acids than Zhao OP-6/O2O2, especially those derived from glycolytic intermediates, but its content of lysine was increased by 51.6% (0.47% vs. 0.31%. The content of amylopectin was 98.5% in Zhao OP-6/o2o2, significantly higher than that in Zhao OP-6/O2O2 (97.7%. Proteomic analyses indicated that o2 introgression not only decreased the accumulation of various zein proteins except for 27-kDa γ-zein, but also affected other endosperm proteins related to amino acid biosynthesis, starch-protein balance, stress response and signal transduction. This study gives us an intriguing insight into the metabolism changes in endosperm of waxy maize introgressed with opaque2.

  14. List context effects in languages with opaque and transparent orthographies: A challenge for models of reading

    Directory of Open Access Journals (Sweden)

    Daniela eTraficante

    2014-09-01

    Full Text Available This paper offers a review of data which show that reading is a flexible and dynamic process and that readers can exert strategic control over it. Two main hypotheses on the control of reading processes have been suggested: the route de-emphasis hypothesis and the time-criterion hypothesis. According to the former, the presence of irregular words in the list might lead to an attenuation of the non-lexical process, while the presence of non-words could trigger a de-emphasis of the lexical route. An alternative account is proposed by the time-criterion hypothesis whereby the reader sets a flexible deadline to initiate the response. According to the latter view, it is the average pronunciation difficulty of the items in the block that modulates the time-criterion for response. However, it is worth noting that the list composition has been shown to exert different effects in transparent compared to opaque orthographies, as the consistency of spelling-sound correspondences can influence the processing costs of the non-lexical pathway. In transparent orthographies, the non-lexical route is not resource demanding and can successfully contribute to the pronunciation of regular words, thus its de-emphasis could not be as useful/necessary as in opaque orthographies. The complex patterns of results from the literature on list context effects are a challenge for computational models of reading which face the problem of simulating strategic control over reading processes. Different proposals suggest a modification of parameter setting in the non-lexical route or the implementation of a new module aimed at focusing attention on the output of the more convenient pathway. Simulation data and an assessment of the models’ fit to the behavioral results are presented and discussed to shed light on the role of the cognitive system when reading aloud.

  15. Three dimensional color measurement of porcelain laminate restorations using resin cements with shade modifiers: a laboratory study

    Directory of Open Access Journals (Sweden)

    Jalali H.

    2005-07-01

    Full Text Available Background and Aim: With the introduction of porcelain veneers to fulfill patients’ esthetic needs, question raises about the ability of the veneers to cover the substructure discoloration. It seems that using shade modifiers under the porcelain veneers can neutralize the discoloration. The goal of this study was to determine the efficacy of shade modifiers in correcting tooth discoloration, when used with resin cements under porcelain veneers. Materials and Methods: In this experimental study, 60 porcelain discs with two thicknesses of 0.7 mm and 2 mm (30 porcelain of each thickness were made from ceramco porcelain powder. 40 of them were in A2 shade and 20 were made by the mixture of A2 shade porcelain powder and porcelain stain to represent tooth discoloration. Then all the laminate discs (0.7 mm were cemented over the 2 mm thick discs to make groups of 10 samples as followed: 1- The first group: laminate discs + resin cement + 2mm thick discs with A2 shade. 2- The second group: laminate discs + resin cement + 2mm thick discolored discs. 3- The third group: laminate discs+ resin cement+ shade modifier+ 2mm thick discolored discs. The color of 30 specimens was measured by spectrophotometer in 2 conditions. 1- To include the specular reflection (SCI. 2- To exclude specular reflection (SCE. In each condition the specimens were measured on both a white background (W and a black one (B. The mean color differences (E of each specimen in the second and third group with the specimens of the first group were calculated. Data were analyzed using Paired sample t-test and P<0.05 of significance. Results: Color measurements showed that in SCIW condition L was significantly different among the three groups except the first and the third. In SCEW condition all the parameters showed significant differences. In SCIB condition, E was not significantly different between the second and the third groups. Hue (h parameter wasn’t different between groups

  16. [Pharmacists as pioneers in porcelain production: what the service, Flora Danica owe to the Bordeaux's apothecary Marc-Hilaire Vilaris].

    Science.gov (United States)

    Devaux, Guy

    2004-01-01

    In 1766, The Bordeaux's apothecary Marc-Hilaire Vilaris (1719-1792) identified with certainty a kaolin's deposit at Saint-Yrieix, in the country of Limousin, allowing so the porcelain manufacture in France and the development of a china clay's and porcelain's dough trade. Archives documents give evidence of regularly supplies of limousin's raw materials by the pharmacist Frantz Heinrich Müller (1732-1820), Director of the Royal china's Manufactury of Denmark, some time before production of the famous table service Flora Danica.

  17. A study on provisional cements, cementation techniques, and their effects on bonding of porcelain laminate veneers.

    Science.gov (United States)

    Vinod Kumar, G; Soorya Poduval, T; Bipin Reddy; Shesha Reddy, P

    2014-03-01

    Minimal tooth preparation is required for porcelain laminate veneers, but interim restorations are a must to protect their teeth against thermal insult, chemical irritation, and to provide aesthetics. Cement remaining after the removal of the provisional restoration can impair the etching quality of the tooth surface and fit and final bonding of the porcelain laminate veneer. This in vitro study examined the tooth surface for remaining debris of cement after removal of a provisional restoration. Determine the presence of cement debris on prepared tooth surface subsequent to the removal of provisional restoration. Determine the cement with the least residue following the cleansing procedures. Determine the effect of smear layer on the amount of residual luting cement. Eighty-four extracted natural anterior teeth were prepared for porcelain laminate veneers. For half of the teeth, the smear layer was removed before luting provisional restorations. Veneer provisional restorations were fabricated and luted to teeth with six bonding methods: varnish combined with glass ionomer cement (GIC), varnish combined with resin modified GIC, varnish, spot etching combined with dual-cure luting cement, adhesive combined with GIC, adhesive combined with resin modified GIC, and adhesive, spot etching combined with dual-cure luting cement. After removal of provisional restorations 1 week later, the tooth surface was examined for residual luting material with SEM. Traces of cement debris were found on all the prepared teeth surfaces for all six groups which were cemented with different methods. Cement debris was seen on teeth subsequent to the removal of provisional's. Dual-cure cement had the least residue following the cleansing procedures. Presence of smear layer had no statistical significance in comparison with cement residue. With the use of adhesive the cement debris was always found to be more than with the use of varnish. GIC showed maximum residual cement followed by dual-cure.

  18. The Perceval S Aortic Valve Implantation in Patients with Porcelain Aorta; is this Ideal Option?

    Science.gov (United States)

    Baikoussis, Nikolaos G; Dedeilias, Panagiotis; Prappa, Efstathia; Argiriou, Michalis

    2017-01-01

    We would like to present in this paper a patient with severe aortic valve stenosis referred to our department for surgical aortic valve replacement. In this patient, it was intraoperatively detected an unexpected heavily calcified porcelain ascending aorta. We present the treatment options in this situation, the difficulties affronted intraoperatively, the significance of the preoperative chest computed tomography scan and the use of the Perceval S aortic valve as ideal bioprosthesis implantation. This is a self-expanding, self-anchoring, and sutureless valve with a wide indication in all patients requiring aortic bioprosthesis. PMID:28074827

  19. Effects of flaw size and auto-glaze treatment on porcelain strength.

    Science.gov (United States)

    Griggs, J A; Thompson, J Y; Anusavice, K J

    1996-06-01

    The functional surfaces of porcelain restorations are often ground to adjust occlusion. This removes the surface glaze and introduces flaws. Re-firing the restoration before final placement produces a self-glaze layer on the surface that may reduce the extent of damage caused by grinding. The objectives of this study were to determine whether re-firing after grinding increases the strength of dental porcelain and to determine whether the effectiveness of this treatment was dependent on the initial flaw size. Six groups, each containing 12 disk specimens, were prepared from experimental body porcelain (No. 36, J.F. Jelenko & Co., Armonk, NY). The specimens were fired under vacuum, ground to a thickness of 1 mm with 240-grit SiC abrasive, and polished through 600-grit on the surface to be subjected to tensile stress. Control Group A consisted of 12 non-indented specimens. Flaws were induced in the remaining groups by means of a Vickers indenter under the following loads: 3.9 N (Group B), 7.8 N (Group C), 11.8 N (Group D), 15.7 N (Group E), and 19.6 N (Group F). Following indentation, half of the specimens from each group were re-fired. The flexure strength of each specimen was determined by means of a piston-on-three-ball biaxial fixture. The TTEST procedure of SAS (1985) indicated a significant difference between the mean strength values of glazed and non-glazed specimens in Group E only (p = 0.55, 0.24, 0.13, 0.07, 0.01, and 0.69 for Groups A to F, respectively). ANOVA with the GLM procedure of SAS (1985) revealed that the mean strength values of groups subjected to five indentation loads were not significantly different (p = 0.45 for glazed specimens and p = 1.00 for non-glazed specimens). These findings support those of Fairhurst et al. (1992) for specimens with smaller flaws that were induced by grinding with 1 micron abrasive grit. The results of the current study indicate that re-firing of porcelain with large surface flaws does not significantly increase the

  20. White-opaque Switching in Different Mating Type-like Locus Gene Types of Clinical Candida albicans Isolates

    Directory of Open Access Journals (Sweden)

    Hou-Min Li

    2016-01-01

    Conclusions: From these analyses, there were comparatively more C. albicans strains classified into serotype B, and the frequency of opaque phase strains was significant in the clinical isolates from China. Genetic, phenotypic, or drug susceptibility patterns were not significantly different from previous studies. MTL a/α isolates could also undergo WO switching which facilitates their survival.

  1. Is Morphological Priming Stronger for Transparent than Opaque Words? It Depends on Individual Differences in Spelling and Vocabulary

    Science.gov (United States)

    Andrews, Sally; Lo, Steson

    2013-01-01

    This experiment used the masked priming lexical decision task to address previous contradictory evidence about the relative strength of priming for (i) transparent pairs (e.g., "worker" "WORK") which are morphologically and semantically related; (ii) opaque pairs (e.g., "corner" "CORN") which appear to be morphological relatives but are not…

  2. Corporate Governance, Opaque Bank Activities, and Risk/Return Efficiency : Pre- and Post-Crisis Evidence from Turkey

    NARCIS (Netherlands)

    De Jonghe, O.G.; Disli, M.; Schoors, K.

    2011-01-01

    Does better corporate governance unambiguously improve the risk/return efficiency of banks? Or does either a re-orientation of banks' revenue mix towards more opaque products, an economic downturn, or tighter supervision create off-setting or reinforcing effects? The authors relate bank efficiency

  3. Is Morphological Priming Stronger for Transparent than Opaque Words? It Depends on Individual Differences in Spelling and Vocabulary

    Science.gov (United States)

    Andrews, Sally; Lo, Steson

    2013-01-01

    This experiment used the masked priming lexical decision task to address previous contradictory evidence about the relative strength of priming for (i) transparent pairs (e.g., "worker" "WORK") which are morphologically and semantically related; (ii) opaque pairs (e.g., "corner" "CORN") which appear to be morphological relatives but are not…

  4. Hot pressing effect on the shear bond strength of dental porcelain to CoCrMoSi alloy substrates with different surface treatments.

    Science.gov (United States)

    Henriques, B; Faria, S; Soares, D; Silva, F S

    2013-01-01

    The purpose of this study was to evaluate the effect of hot pressing on the shear bond strength of a CoCrMoSi alloy to a low-fusing feldspathic porcelain, for two types of surface treatments: polished and grit-blasted. Moreover, the shear strength of hot pressed porcelain was also compared with that of conventional vacuum sintered porcelain. Bond strength of metal-porcelain composites were assessed by the means of a shear test performed in a universal test machine until fracture. Fracture surfaces and interfaces were investigated by optical microscope, stereomicroscope and SEM/EDS. Data was analyzed with Shapiro-Wilk test to test the assumption of normality. The 2-way ANOVA followed by Tukey HSD multiple comparison test was used to compare shear bond strength results and the t-test was used to compare the porcelain shear strength (pporcelain. This study revealed that metal-ceramic bond strength is maximized for hot pressed porcelain onto rough metal substrates, with lower variability in results. Hot pressing technique was also shown to enhance the cohesion of porcelain.

  5. Avaliação da influência dos tipos de tratamento superficial da porcelana glazeada na colagem de braquetes ortodônticos Evaluation of the influence of porcelain conditioning techniques in orthodontic brackets bonding

    Directory of Open Access Journals (Sweden)

    Camila Belo Falcão

    2009-06-01

    Full Text Available OBJETIVO: o objetivo deste trabalho foi avaliar a influência do tipo de tratamento superficial da porcelana na resistência adesiva da colagem de braquetes ortodônticos e o modo de fratura após a descolagem. METODOLOGIA:foram confeccionados 80 corpos-de-prova de porcelana, divididos em quatro grupos (n = 18 de acordo com os diferentes tratamentos de superfície: (G1 ponta diamantada; (G2 ponta diamantada e silano; (G3 ácido hidrofluorídrico e (G4 ácido hidrofluorídrico e silano. Após o preparo das superfícies, braquetes Edgewise (Morelli foram colados com resina (Transbond XT, 3M e submetidos ao teste de cisalhamento. Os resultados foram avaliados estatisticamente pelo teste de Kruskal-Wallis. RESULTADO: o grupo G1 apresentou uma média de resistência de 3,35, o G2 3,97, o G3 2,56 e o G4 3,10. CONCLUSÃO: constatou-se que não houve diferença estatisticamente significativa na resistência adesiva do braquete entre os tipos de tratamentos estudados (p > 0,05 e os modos de fratura ocorreram, em sua grande maioria, na interface braquete/resina. Este estudo indica que todos os tipos de tratamentos apresentados são eficientes para a colagem.AIM: The aim of this study was to evaluate the influence of various porcelain surface treatments on the strength of orthodontic brackets bonded to porcelain and the fracture mode after debonding. METHODS: Eighty samples of porcelain were randomly divided into four groups according to their surface preparation, as follows: (G1 diamond bur, (G2 diamond bur with silane, (G3 hydrofluoridic acid and (G4 hydrofluoridic acid with silane. After surface treatment the Edgewise brackets (Morelli were bonded with resin (Transbond XT, 3M and sheared off. The Kruskal-Wallis statistical test were applied on the data. RESULTS: There were no statistically significant differences in bond strength between the groups (p > 0.05 and the fracture mode in most of the porcelain occurred in the composite/bracket interface. The

  6. Strength and marginal fit of full and partial porcelain crowns on Brånemark implants.

    Science.gov (United States)

    Kersten, S; Tiedemann, C

    2000-02-01

    The aim of the present study was to evaluate strength and marginal fit of different designed single crowns screwed on titanium implants (Brånemark) without the usage of any abutment. Seven test groups with 10 specimens each (standardized maxillary central incisor crowns) were fabricated of Empress (staining/veneering technique), metal-based Empress (staining/veneering technique), metal-based In-Ceram and metal ceramic (with/without cervical porcelain margin). The marginal fit of 5 specimens of each group was evaluated (SEM-Analysis) and the crowns were incisally loaded at a 30 degrees angle in a Zwick testing machine until fracture. The 5 remaining specimens underwent a marginal evaluation (SEM-analyses) before and after thermo-mechanical stressing (tms) and were loaded in the Zwick testing machine as well. All Empress ceramic crowns without metal reinforcement fractured during fixing procedure on the implant (32 N cm). The gap medians of the fixed crowns ranged from 11 microns (metal ceramic crowns) to 34 microns (metal ceramic crowns with porcelain margin). No significant differences in gap width were observed before and after tms. In the strength analyses screw-binding forces (SBF) of about 135 N were registered in all test groups. Fracture failure forces (FFF) reached up to 280 N. The indication of the crown designs presented in this study is limited in clinical use because of low stability and esthetics.

  7. Effect of substitution of sand stone dust for quartz and clay in triaxial porcelain composition

    Indian Academy of Sciences (India)

    M K Haldar; S K Das

    2012-10-01

    Quartz and kaolin were partially substituted by sand stone dust (a siliceous byproduct of Indian stone cutting and polishing industries) in a traditional triaxial porcelain composition consisting of kaolin, quartz and feldsper. The effect of substitution upon heating at different temperatures (1050–1150°C) were studied by measuring the linear shrinkage, bulk density, porosity and flexural strength. Qualititative phase and microstructural analysis on selected samples were carried out using XRD and SEM/EDX technique. The results show that the samples of all the batches achieved higher density (2.50 g/cc) and almost full vitrification (<0.1% apparent porosity) at around 1115°C compared to around 1300°C for traditional triaxial porcelain composition. As high as 70 MPa flexural strength was obtained in most of the vitrified samples. No significant variation in physico-mechanical properties was observed in between the composition. XRD studies on selected samples show presence of mainly quartz phase both at low and high temperatures. SEM photomicrographs of the 1115°C heated specimen show presence of quartz grain and glassy matrix. Few quartz grains (20–40m) are associated with circumferential cracks around them.

  8. Bonding of Metal Orthodontic Attachments to Sandblasted Porcelain and Zirconia Surfaces

    Science.gov (United States)

    2016-01-01

    This study evaluates tensile bond strength (TBS) of metal orthodontic attachments to sandblasted feldspathic porcelain and zirconia with various bonding protocols. Thirty-six (36) feldspathic and 36 zirconia disc samples were prepared, glazed, embedded in acrylic blocks and sandblasted, and divided into three groups according to one or more of the following treatments: hydrofluoric acid 4% (HF), Porcelain Conditioner silane primer, Reliance Assure® primer, Reliance Assure plus® primer, and Z Prime™ plus zirconia primer. A round traction hook was bonded to each sample. Static tensile bond strength tests were performed in a universal testing machine and adhesive remnant index (ARI) scoring was done using a digital camera. One-way ANOVA and Pearson chi-square tests were used to analyze TBS (MPa) and ARI scores. No statistically significant mean differences were found in TBS among the different bonding protocols for feldspathic and zirconia, p values = 0.369 and 0.944, respectively. No statistically significant distribution of ARI scores was found among the levels of feldspathic, p value = 0.569. However, statistically significant distribution of ARI scores was found among the levels of zirconia, p value = 0.026. The study concluded that silanization following sandblasting resulted in tensile bond strengths comparable to other bonding protocols for feldspathic and zirconia surface.

  9. First Reported Case of Reactive Airway Dysfunction Syndrome in a Laborer Due to Porcelain Tile Dust

    Directory of Open Access Journals (Sweden)

    Tasleem Arif

    2013-06-01

    Full Text Available Reactive airway dysfunction syndrome (RADS is a type of non-immunologically mediated asthma-like disease. It usually occurs after a massive exposure to an irritating substance in the atmosphere in the form of smoke, fumes, gases, and vapor. Unlike bronchial asthma, there is no latency to the symptoms seen in RADS. A number of agents are known to cause RADS, but tile dust, as an etiological agent, has not been previously reported. We report a 45-year-old male laborer, who presented with an acute onset of cough, chest tightness, breathlessness, and audible wheeze after his first time exposure to porcelain tile dust within 5 hours of exposure. Lab tests, including, chest X-ray, electrocardiogram, air blood gas analysis, and serum IgE, were unremarkable. Spirometry showed a mild obstruction [forced expiratory volume in 1 second (FEV1=72% of predicted], while the bronchodilator reversibility test was significant(14% increase in FEV1 above the baseline.Bronchial biopsy revealed a chronic inflammatory reaction with lymphocytic and plasma cell infiltration and more importantly a striking absence of eosinophils. To the best of our knowledge, this is the first reported case of RADS as a result of exposure to tile dust (porcelain ceramics.

  10. Effect of the Chemical Composition on The Pyroplastic Deformation of Sanitaryware Porcelain Body

    Science.gov (United States)

    Yeşim Tunçel, Derya; Kerim Kara, Mustafa; Özel, Emel

    2011-10-01

    Pyroplastic deformation is the bending of a ceramic specimen caused by gravity during heat treatment. It can be defined as the loss of shape of product during its firing. Pyroplastic deformation is related to properties of liquid phases formed during firing. Therefore, the effect of the chemical composition on the pyroplastic deformation of sanitaryware porcelain was investigated in this study. Systematical compositional arrangements were made according to different combinations of (SiO2/Al2O3) and (Na2O/K2O) ratios by using Seger formula approach. Pyroplastic deformation behaviour of compositions within a controlled firing regime was investigated by using fleximeter. The bodies were also prepared in a special form by slip casting method at laboratory scale in order to determine the pyroplastic deformation of the samples. The experimental results showed that a definite combination at SiO2/Al2O3 ratio of 5 and Na2O/K2O ratio of 4 give the lowest pyroplastic deformation in the porcelain body formulations. The pyroplastic deformation value of this composition was determined as 25 mm which is 44% lower than that of the standard composition (45 mm).

  11. Effect of water storage on the silanization in porcelain repair strength.

    Science.gov (United States)

    Berry, T; Barghi, N; Chung, K

    1999-06-01

    This study examined the long-term water storage affect of silanization on shear bond strength of composite resin to porcelain. One hundred and sixty square-shaped specimens were fabricated and sanded flat sequentially with silicone carbide papers. The specimens were then placed into four groups and 16 subgroups of 10 specimens each randomly. Four commercially available silane systems, two one-mix and two two-mix, were tested in this study. Teflon tubes with an internal diameter of 2.97 mm and 2 mm in height were filled with a dual cure composite resin (Mirage FLC), placed on the silanated surfaces and light-cured for 120 s. Specimens were stored in room temperature water and subjected to shear bond strength testing after 24 h, 1 week, 1 month and 3 month periods of immersion. An Instron Universal testing machine with a crosshead speed of 0.5 mm/min was used for the testing. The mean values of the shear bond strengths ranged from 4.38 MPa (24-h period) to 23.90 MPa (3-month period). ANOVA and Scheffe' tests were used to analyse data with confidence level at 95%. All groups recorded an increase in bond strength after one week as compared with the 24-h period (Psilanization of porcelain increased during the experimental period. The bond strength also varied for different silanes used in this study.

  12. Bonding of Metal Orthodontic Attachments to Sandblasted Porcelain and Zirconia Surfaces

    Directory of Open Access Journals (Sweden)

    Amitoj S. Mehta

    2016-01-01

    Full Text Available This study evaluates tensile bond strength (TBS of metal orthodontic attachments to sandblasted feldspathic porcelain and zirconia with various bonding protocols. Thirty-six (36 feldspathic and 36 zirconia disc samples were prepared, glazed, embedded in acrylic blocks and sandblasted, and divided into three groups according to one or more of the following treatments: hydrofluoric acid 4% (HF, Porcelain Conditioner silane primer, Reliance Assure® primer, Reliance Assure plus® primer, and Z Prime™ plus zirconia primer. A round traction hook was bonded to each sample. Static tensile bond strength tests were performed in a universal testing machine and adhesive remnant index (ARI scoring was done using a digital camera. One-way ANOVA and Pearson chi-square tests were used to analyze TBS (MPa and ARI scores. No statistically significant mean differences were found in TBS among the different bonding protocols for feldspathic and zirconia, p values = 0.369 and 0.944, respectively. No statistically significant distribution of ARI scores was found among the levels of feldspathic, p value = 0.569. However, statistically significant distribution of ARI scores was found among the levels of zirconia, p value = 0.026. The study concluded that silanization following sandblasting resulted in tensile bond strengths comparable to other bonding protocols for feldspathic and zirconia surface.

  13. colorimetric evaluation of Cercon zirconia and metal ceramic restorations in two thicknesses of veneering porcelain

    Directory of Open Access Journals (Sweden)

    Dorriz H

    2011-02-01

    Full Text Available "nBackground and Aims: The aim of this study was to evaluate the effect of zirconia and base metal cores on the color of restorations. Furthermore, the effect of different backings on the color of cercon zirconia was evaluated."nMaterials and Methods: The specimens were Cercon zirconia and metal ceramic discs with "high Au" and "base metal" alloys. Cercon zirconia discs were veneered with veneering shade of A2 and two thickness of porcelain"n(0.7 mm, 1.2 mm. There were 3 discs in each group. Metal ceramic discs were made of "nickel-chromium" alloy (Verobond and "high Au" alloy (World 89 and two shades (A2, A3.5 and two thicknesses of veneering porcelain. 3 types of backing (high Au, nickel-chromium and A3 shade composite were made for Cercon zirconia discs. Spectrophotometric evaluation of zirconia discs (on 3 backings and metal ceramic discs was done. One-way ANOVA and Tukey tests were used for data analysis."nResults: There were no significant differences between the amounts of L*, a*, b* for Cercon zirconia on different backings (P>0.05. In comparison between different core groups, a* was significantly higher in metal ceramic groups compared with that of zirconia groups (P<0.05."nConclusion: Cercon zirconia can completely mask the underlying backing.

  14. The effect of abrasive blasting on the strength of a joint between dental porcelain and metal base.

    Science.gov (United States)

    Pietnicki, Krzysztof; Wołowiec, Emilia; Klimek, Leszek

    2014-01-01

    This paper presents the effect of selected parameters of abrasive blasting on the strength of a joint between dental porcelain and metal base. Experiments were conducted for different grain sizes of abrasive material and different blasting angles, with a constant blasting pressure. InLine dental porcelain was fused on samples of cobalt-chromium alloy following abrasive blasting; they were subsequently subjected to shearing forces on a testing machine. The fractures were observed under an electron scanning microscope in order to determine the character and course of fracturing. Strength tests showed that the grain size of abrasive material was a parameter with the greatest effect on the strength. The best effects were achieved for samples subjected to abrasive blasting with material with grain size of 110 μm. No statistically significant differences were found for the strength of samples worked at different angles. The results of the fractographic examinations have shown that in all the samples, fracturing occurred mainly along the porcelain-metal boundary, with few cases of fracturing through porcelain.

  15. High-performance and anti-stain coating for porcelain stoneware tiles based on nanostructured zirconium compounds.

    Science.gov (United States)

    Ambrosi, Moira; Santoni, Sergio; Giorgi, Rodorico; Fratini, Emiliano; Toccafondi, Nicola; Baglioni, Piero

    2014-10-15

    The technological characteristics of porcelain stoneware tiles make them suitable for a wide range of applications spanning far beyond traditional uses. Due to the high density, porcelain stoneware tiles show high bending strength, wear resistance, surface hardness, and high fracture toughness. Nevertheless, despite being usually claimed as stain resistant, the surface porosity renders porcelain stoneware tiles vulnerable to dirt penetration with the formation of stains that can be very difficult to remove. In the present work, we report an innovative and versatile method to realize stain resistant porcelain stoneware tiles. The tile surface is treated by mixtures of nanosized zirconium hydroxide and nano- and micron-sized glass frits that thanks to the low particle dimension are able to penetrate inside the surface pores. The firing step leads to the formation of a glass matrix that can partially or totally close the surface porosity. As a result, the fired tiles become permanently stain resistant still preserving the original esthetical qualities of the original material. Treated tiles also show a remarkably enhanced hardness due to the inclusion of zirconium compounds in the glass coating.

  16. Implant-supported fixed dental prostheses with CAD/CAM-fabricated porcelain crown and zirconia-based framework.

    Science.gov (United States)

    Takaba, Masayuki; Tanaka, Shinpei; Ishiura, Yuichi; Baba, Kazuyoshi

    2013-07-01

    Recently, fixed dental prostheses (FDPs) with a hybrid structure of CAD/CAM porcelain crowns adhered to a CAD/CAM zirconia framework (PAZ) have been developed. The aim of this report was to describe the clinical application of a newly developed implant-supported FDP fabrication system, which uses PAZ, and to evaluate the outcome after a maximum application period of 36 months. Implants were placed in three patients with edentulous areas in either the maxilla or mandible. After the implant fixtures had successfully integrated with bone, gold-platinum alloy or zirconia custom abutments were first fabricated. Zirconia framework wax-up was performed on the custom abutments, and the CAD/CAM zirconia framework was prepared using the CAD/CAM system. Next, wax-up was performed on working models for porcelain crown fabrication, and CAD/CAM porcelain crowns were fabricated. The CAD/CAM zirconia frameworks and CAD/CAM porcelain crowns were bonded using adhesive resin cement, and the PAZ was cemented. Cementation of the implant superstructure improved the esthetics and masticatory efficiency in all patients. No undesirable outcomes, such as superstructure chipping, stomatognathic dysfunction, or periimplant bone resorption, were observed in any of the patients. PAZ may be a potential solution for ceramic-related clinical problems such as chipping and fracture and associated complicated repair procedures in implant-supported FDPs.

  17. Survey of the Baihe Porcelain Kiln-site in Gongyi City,Henan%河南巩义市白河瓷窑遗址调查

    Institute of Scientific and Technical Information of China (English)

    郑州市文物考古研究所; 巩义市文物保护管理所

    2001-01-01

    In October and November of 1998, Zhengzhou Municipal Institute of Cultural Relics and Archaeology undertook a survey on the porcelain kiln site in the upper valley of the Baihe river, Gongyi City, Henan Province, and a great number of porcelain shards and kiln implements have been found. The findings are mainly from the Tang Dynasty, while some of them might have been the remains of the Sui and the Song Dynasties. The kiln site was famous for its white porcelain items and some of them were tributes to the Tang Emperors.

  18. Radio-opaque ethylcellulose-ethanol is a safe and efficient sclerosing agent for venous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Dompmartin, Anne; Barrellier, Marie-Therese [Universite de Caen Basse Normandie, CHU Caen, Department of Dermatology, Caen (France); Blaizot, Xavier; Chene, Yannick; Gaillard, Cathy [Universite de Caen Basse Normandie, CHU Caen, Clinical Research and Biostatistical Unit, Caen (France); Theron, Jacques [Universite de Caen Basse Normandie, CHU Caen, Neuroradiology, Caen (France); Hammer, Frank [Universite Catholique de Louvain, Cliniques Universitaires St Luc, Department of Vascular and Interventional Radiology, Center for Vascular Anomalies, Brussels (Belgium); Labbe, Daniel [Universite de Caen Basse Normandie, CHU Caen, Plastic Surgery, Caen (France); Leroyer, Robert; Chedru, Valerie; Ollivier, Catherine [Universite de Caen Basse Normandie, CHU Caen, Pharmacy Department, Caen (France); Vikkula, Miikka [Universite catholique de Louvain, de Duve Institute, Laboratory of Human Molecular Genetics, Brussels (Belgium); Boon, Laurence M. [Universite Catholique de Louvain, Cliniques Universitaires St Luc, Division of Plastic Surgery, Center for Vascular Anomalies, Brussels (Belgium); Universite catholique de Louvain, de Duve Institute, Laboratory of Human Molecular Genetics, Brussels (Belgium)

    2011-12-15

    To evaluate the efficacy and safety of gelified ethanol, a newly developed sclerosing agent for slow-flow vascular malformations. Seventy-nine sclerotherapy procedures were performed on 44 patients with 37 venous malformations, 2 glomuvenous malformations, 2 lymphatic malformations, 2 lymphatico-venous malformations, and 1 Klippel-Trenaunay syndrome. The median injected volume was 1.00 mL/site of injection. Effects of sclerotherapy on pain, functional and cosmetic disturbance were statistically evaluated with a final result score. Local and systemic complications were recorded. The mean Visual Analogue Scores were 5.20 {+-} 2.81 before and 1.52 {+-} 1.25 after treatment (p < 0.001). Functional and aesthetic improvement was achieved in 31/35 patients (89%) and in 33/41 (80%), respectively. Minor local side effects included necrosis with or without issue of ethylcellulose, palpable residue, and hematoma. No systemic side-effects occurred. Per mL used, radio-opaque gelified ethanol is at least as effective as absolute ethanol. No systemic complication was observed, as only a low dose of ethanol was injected. Indications for sclerotherapy can be widened to areas with higher risk for local side effects (hands and periocular region), as ethanol is trapped in the lesion. Careful injection procedure is though necessary, because only a limited amount of ethylcellulose can be used per puncture. (orig.)

  19. On the Ionisation of Warm Opaque Interstellar Clouds and the Intercloud Medium

    CERN Document Server

    Sciama, Dennis William

    1997-01-01

    In this paper we use a number of observations to construct an integrated picture of the ionisation in the interiors of quiescent warm opaque interstellar clouds and in the intercloud medium (ICM) outside dense HII regions and hot dilute bubbles. Our main conclusion is that within $\\sim$ 1kpc of the sun the ionisation rate of hydrogen per unit volume in both the interiors of such clouds and in the ICM is independent of the local density of neutral hydrogen, and varies with position by less than $\\sim$ 20 per cent. These conclusions strongly favour the decaying neutrino hypothesis for the ionisation of the interstellar medium in these regions. Our analysis is based on a variety of observations, of which the most remarkable is the discovery by Spitzer and Fitzpatrick (1993) that, in the four slowly moving clouds along the line of sight to the halo star HD93521, the column densities of both SII and CII$^*$, which individually range over a factor $\\sim$4, are proportional to the column density of HI to within $\\si...

  20. Direct laser writing of microstructures on optically opaque and reflective surfaces

    Science.gov (United States)

    Rekštytė, S.; Jonavičius, T.; Malinauskas, M.

    2014-02-01

    Direct laser writing (DLW) based on ultra-localized polymerization is an efficient way to produce three-dimensional (3D) micro/nano-structures for diverse applications in science and industry. It is attractive for its flexibility to materialize CAD models out of wide spectrum of materials on the desired substrates. In case of direct laser lithography, photo-crosslinking can be achieved by tightly focusing ultrashort laser pulses to a photo- or thermo-polymers. Selectively exposing material to laser radiation allows creating fully 3D structures with submicrometer spatial resolution. In this paper we present DLW results of hybrid organic-inorganic material SZ2080 on optically opaque and reflective surfaces, such as silicon and various metals (Cr, Ti, Au). Our studies prove that one can precisely fabricate 2D and 3D structures with lower than 1 μm spatial resolution even on glossy or rough surfaces (surface roughness rms 0.068-0.670 μm) using sample translation velocities of up to 1 mm/s. Using femtosecond high pulse repetition rate laser, sample translation velocity can reach over 1 mm/s ensuring repeatable submicrometer structuring resolution.

  1. Chemical and explosives point detection through opaque containers using spatially offset Raman spectroscopy (SORS)

    Science.gov (United States)

    Loeffen, Paul W.; Maskall, Guy; Bonthron, Stuart; Bloomfield, Matthew; Tombling, Craig; Matousek, Pavel

    2011-05-01

    Spatially Offset Raman Spectroscopy (SORS) is a novel technique used to identify the chemical Raman signature of threat materials within a few seconds through common non-metallic containers, including those containers which may not yield to inspection by conventional backscatter Raman. In particular, some opaque plastic containers and coloured glass bottles can be difficult to analyze using conventional backscatter Raman because the signal from the contents is often overwhelmed by the much stronger Raman signal and/or fluorescence originating from the container itself. SORS overcomes these difficulties and generates clean Raman spectra from both the container and the contents with no prior knowledge of either. This is achieved by making two, or more, Raman measurements at various offsets between the collection and illumination areas, each containing different proportions of the fingerprint signals from the container and content materials. Using scaled subtraction, or multivariate statistical methods, the two orthogonal signals can be separated numerically, thereby providing a clean Raman spectrum of the contents without contamination from the container. Consequently, SORS promises to significantly improve threat detection capability and decrease the falsealarm rate compared with conventional Raman spectroscopy making it considerably more suitable as an alarm resolution methodology (e.g. at airports). In this paper, the technique and method are described and a study of offset value optimization is described illustrating the difference between one and two fixed spatial offsets. It is concluded that two fixed offsets yield an improvement in the SORS measurement which will help maximize the threat detection capability.

  2. Optical absorbance measurements of opaque liquids by pulsed laser photoacoustic spectroscopy.

    Science.gov (United States)

    Schmid, Thomas; Panne, Ulrich; Niessner, Reinhard; Haisch, Christoph

    2009-03-15

    In many relevant industrial applications, UV-vis online process monitoring is hampered by light scattering and opacity of the samples, whereas diluted and filtered samples are rarely available. Pulsed laser photoacoustic (PA) spectroscopy allows the measurement of both high and low absorptions without any need for sample preparation. An optimized detection geometry for absorption measurements in opaque liquids is described. The proposed PA sensor was realized by using two orthogonal detectors based on piezoelectric poly(vinylidene fluoride) (PVDF). Laser-induced pressure waves were sensed perpendicularly to (side-on mode) and along the axis of the laser beam (forward mode). Pressure waves generated by a single laser pulse, optical transmission and absorption, as well as the speed of sound in liquid samples were determined simultaneously using time-resolved detection. Evaluation of the PA signal permits the determination of absorption coefficients ranging from 0.1 to 1000 cm(-1). The influence of absorbing or scattering compounds on the signal was investigated in dye solutions and suspensions of TiO(2) particles.

  3. Infrared-Transparent Visible-Opaque Fabrics for Wearable Personal Thermal Management

    CERN Document Server

    Tong, Jonathan K; Boriskina, Svetlana V; Loomis, James; Xu, Yanfei; Chen, Gang

    2015-01-01

    Personal cooling technologies locally control the temperature of an individual rather than a large space, thus providing personal thermal comfort while supplementing cooling loads in thermally regulated environments. This can lead to significant energy and cost savings. In this study, a new approach to personal cooling was developed using an infrared-transparent visible-opaque fabric (ITVOF), which provides passive cooling via the transmission of thermal radiation emitted by the human body directly to the environment. Here, we present a conceptual framework to thermally and optically design an ITVOF. Using a heat transfer model, the fabric was found to require a minimum infrared (IR) transmittance of 0.644 and a maximum IR reflectance of 0.2 to ensure thermal comfort at ambient temperatures as high as 26.1oC (79oF). To meet these requirements, an ITVOF design was developed using synthetic polymer fibers with an intrinsically low IR absorptance. These fibers were then structured to minimize IR reflection via w...

  4. Polarized properties of the directional-hemispherical reflectance and emissivity of an opaque surface

    Science.gov (United States)

    Anderson, Richard A.

    1992-12-01

    The measurement of temperature of the earth's surface from space is an important remote sensing parameter and depends upon the surface emissivity. Directional-hemispherical emissivities have been measured for several different soil samples with 10 micrometers CO2 laser radiation. The CO2 laser is a possible polarized source for active remote sensing. The angular variation of the directional-hemispherical emissivity has been calculated from directional reflectance measurements for horizontal and vertical polarized CO2 radiation on different soil samples and they depended upon the polarization of the incident light. In this paper it is demonstrated that the directional-hemispherical reflectance, absorbance, and emissivity are 4 X 4 Mueller matrices. For uniform incident radiance of definite state of polarization incident on an area dA' within a projected solid angle d(Omega) ' equals Cos(Theta) 'd(omega) ' at angles ((Theta) ', (phi) ') Kirchhoff's formula relating the emissivity and reflectance involves definite sums and/or differences of Mueller matrix components of the reflectance and emissivity and depends on the polarization of the incident light. The directional-hemispherical emissivity of opaque soil samples are polarization dependent.

  5. The Effect of Porcelain Firing and Type of Finish Line on the Marginal Fit of Zirconia Copings

    Directory of Open Access Journals (Sweden)

    Mahroo Vojdani

    2015-06-01

    Full Text Available Statement of the Problem: Although all-ceramic restorations are broadly used, there is a lack of information concerning how their fit is affected by fabrication procedure and marginal configuration. Purpose: The purpose of this study was to evaluate the marginal fit of zirconia CAD/CAM ceramic crowns before and after porcelain firing. The influence of fin-ish line configuration on the marginal fit was also evaluated. Materials and Method: Twenty standardized zirconia CAD/CAM copings were fabricated for chamfer and shoulder finish line designs (n=10. The marginal fit of specimens was measured on 18 points, marked on the master metal die by using a digital microscope. After the crowns were finalized by porcelain veneering, the measurements of marginal fit were performed again. The means and standard deviations were calculated and data were analyzed using student’s t-test and paired t-test (α=0.05. Results: There were significant differences between marginal fit of chamfer and shoulder finish line groups before and after porcelain firing (p= 0.014 and p= 0.000, respectively. The marginal gap of copings with shoulder finish line was significantly smaller than those with chamfer configuration (p= 0.000, but there were no significant differences between the two marginal designs, after porcelain firing (p= 0.341. Conclusion: Porcelain veneering was found to have a statistically significant influ-ence on the marginal fit of zirconia CAD/CAM crowns. Both margin configurations showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.

  6. Evolution of silica coating layer on titanium surface and the effect on the bond strength between titanium and porcelain

    Science.gov (United States)

    Wang, Aili; Ge, Chaoqun; Yin, Hengbo; Gao, Yu; Jiang, Tao; Xia, Chunlin; Wu, Gang; Wu, Zhanao

    2013-07-01

    SiO2 coating layers were uniformly anchored at the surfaces of sandblasted/pre-oxidized commercially pure titanium (CP-Ti) substrates by the chemical deposition method using Na2SiO3 as the SiO2 precursor at the pH values of 8-10 with the Na2SiO3 concentrations of 0.05-0.5 mol/L. The SiO2 coating layers were composed of small-sized SiO2 nanoparticles with the average particle sizes ranging from 18.0 to 20.5 nm. After firing porcelain (Ti-22) on SiO2-coated sandblasted/pre-oxidized CP-Ti substrates, the bond strengths of CP-Ti and porcelain ranged from 33.56 to 40.43 MPa, which were detected by the three-point flexure bend test method. In the absence of SiO2 interlayer, the bond strength of sandblasted/pre-oxidized CP-Ti and porcelain was 25.6 MPa. The bond strengths in the presence of SiO2 interlayer were higher than that in the absence of SiO2 interlayer. On the other hand, when the CP-Ti substrates were only treated by hydrochloric acid pickling, the bond strengths of SiO2-coated acid-pickled CP-Ti and porcelain ranged from 12.99 to 16.59 MPa. The chemical interaction between the SiO2 interlayers and the oxidized CP-Ti surfaces probably played an important role in increasing the bond strength of CP-Ti and porcelain.

  7. Influence of porcelain firing and cementation on the marginal adaptation of metal-ceramic restorations prepared by different methods.

    Science.gov (United States)

    Kaleli, Necati; Saraç, Duygu

    2017-05-01

    Marginal adaptation plays an important role in the survival of metal-ceramic restorations. Porcelain firings and cementation may affect the adaptation of restorations. Moreover, conventional casting procedures and casting imperfections may cause deteriorations in the marginal adaptation of metal-ceramic restorations. The purpose of this in vitro study was to compare the marginal adaptation after fabrication of the framework, porcelain application, and cementation of metal-ceramic restorations prepared by using the conventional lost-wax technique, milling, direct metal laser sintering (DMLS), and LaserCUSING, a direct process powder-bed system. Alterations in the marginal adaptation of the metal frameworks during the fabrication stages and the precision of fabrication methods were evaluated. Forty-eight metal dies simulating prepared premolar and molar abutment teeth were fabricated to investigate marginal adaptation. They were divided into 4 groups (n=12) according to the fabrication method used (group C serving as the control group: lost-wax method; group M: milling method; group LS: DMLS method; group DP: direct process powder-bed method). Sixty marginal discrepancy measurements were recorded separately on each abutment tooth after fabrication of the framework, porcelain application, and cementation by using a stereomicroscope. Thereafter, each group was divided into 3 subgroups according to the measurements recorded in each fabrication stage: subgroup F (framework), subgroup P (porcelain application), and subgroup C (cementation). Data were statistically analyzed with univariate analysis of variance (followed by 1-way ANOVA and Tamhane T2 test (α=.05). The lowest marginal discrepancy values were observed in restorations prepared by using the direct process powder-bed method, and this was significantly different (Pdirect process powder-bed method is quite successful in terms of marginal adaptation. The marginal discrepancy increased after porcelain application

  8. A kinetic study on the development of porosity in porcelain stoneware tile sintering

    Directory of Open Access Journals (Sweden)

    Jazayeri, S. H.

    2007-02-01

    Full Text Available The aim of this work is to develop a mathematical model to study the mechanism of elimination of total porosity as a function of soaking time using the Navier-Stokes. Then, parameters of the model such as kinetic constants and apparent activation energy are calculated on the basis of experimental data for a standard porcelain stoneware tile composition. The theoretical data calculated from the model are in good agreement with the experimental data. Using the model developed, it is possible to estimate the best soaking time to obtain minimum total porosity at a given firing temperature . The effects of nepheline on sintering process of porcelain stoneware tile is investigated. It was found that when the nepheline syenite content of the starting mix was increased to 10%, the constant kp of the kinetic equation also increased. The results showed that addition of nepheline to composition of porcelain stoneware bodies was influenced remarkably suitable soaking time to obtain the minimum total porosity and increased shrinkage and bulk density while total and closed porosity fall down.

    El propósito de este trabajo es desarrollar un modelo matemático tipo Navier-Stokes para estudiar el mecanismo de eliminación de la porosidad en función del tiempo de maduración en cocción. Los parámetros del modelo tales como las constantes cinéticas y la energía de activación aparente se calcularon a partir de datos experimentales para una composición de gres porcelánico estándar. Los datos teóricos obtenidos a partir del modelo están en buena concordancia con los datos experimentales. Se investigaron los efectos de la nefelina en el gres porcelánico, encontrado que cuando se aumenta el contenido hasta un 10%, la constante de la ecuación cinética kp aumenta. Empleando el modelo desarrollado, es posible estimar el tiempo de maduración en cocción para obtener la porosidad mínima (se alcanza la eliminación de la porosidad debido a la presi

  9. White-opaque Switching in Different Mating Type-like Locus Gene Types of Clinical Candida albicans Isolates

    Science.gov (United States)

    Li, Hou-Min; Shimizu-Imanishi, Yumi; Tanaka, Reiko; Li, Ruo-Yu; Yaguchi, Takashi

    2016-01-01

    Background: Candida albicans (C. albicans) can become a pathogen causing superficial as well as life-threatening systemic infections, especially in immunocompromised patients. Many phenotypic attributes contribute to its capacity to colonize human organs. In our study, 93 C. albicans isolates from patients of various candidiasis in a hospital of China were surveyed. We aimed to investigate the white-opaque (WO) switching competence, drug sensitivity, and virulence of mating type-like (MTL) a/α isolates. Methods: Internal transcribed spacer (ITS) gene and the MTL configuration were detected in all the isolates by reverse transcription-polymerase chain reaction. White/opaque phenotype and doubling time of cell growth were determined. The minimum inhibitory concentrations of antifungal agent were measured using broth microdilution method. Results: Sixty-four isolates (69.6%) were classified to serotype A, 19 (20.6%) to serotype B, and 9 (9.8%) to serotype C. Moreover, phylogenetic analysis showed that these isolates were divided into four different subgroups of ITS genotypes. Most of our clinical isolates were MTLa/α type, while 6.8% remained MTLa or MTLα type. The frequency of opaque phenotype was 71.0% (66 isolates). Following the guidelines of Clinical and Laboratory Standards Institute M27-A3, all isolates were susceptible to caspofungin and a few (0.6–3.2%) of them showed resistance against amphotericin B, flucytosine, fluconazole, itraconazole, and voriconazole. Conclusions: From these analyses, there were comparatively more C. albicans strains classified into serotype B, and the frequency of opaque phase strains was significant in the clinical isolates from China. Genetic, phenotypic, or drug susceptibility patterns were not significantly different from previous studies. MTLa/α isolates could also undergo WO switching which facilitates their survival. PMID:27824006

  10. Gravity Bias in Young and Adult Chimpanzees ("Pan Troglodytes"): Tests with a Modified Opaque-Tubes Task

    Science.gov (United States)

    Tomonaga, Masaki; Imura, Tomoko; Mizuno, Yuu; Tanaka, Masayuki

    2007-01-01

    Young human children at around 2 years of age fail to predict the correct location of an object when it is dropped from the top of an S-shape opaque tube. They search in the location just below the releasing point (Hood, 1995). This type of error, called a "gravity bias", has recently been reported in dogs and monkeys. In the present study, we…

  11. Cloud-Aerosol Interactions: Retrieving Aerosol Ångström Exponents from Calipso Measurements of Opaque Water Clouds

    Directory of Open Access Journals (Sweden)

    Vaughan Mark

    2016-01-01

    Full Text Available Backscatter and extinction from water clouds are well-understood, both theoretically and experimentally, and thus changes to the expected measurement of layer-integrated attenuated backscatter can be used to infer the optical properties of overlying layers. In this paper we offer a first look at a new retrieval technique that uses CALIPSO measurements of opaque water clouds to derive optical depths and Ångström exponents for overlying aerosol layers.

  12. Study and rheological characterization of various bone ash porcelain formulations; Estudo e caracterizacao reologica de diferentes formulacoes de porcelana de cinza de ossos

    Energy Technology Data Exchange (ETDEWEB)

    Carus, L.A.; Bento, L.; Braganca, S.R., E-mail: laucarus@gmail.com [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Programa de Pos-Graduacao em Engenharia de Minas, Metalurgica e de Materiais

    2012-07-01

    The bone ash porcelain is a widely accepted product on the market because their qualities such as high strength and whiteness, to differ from common table porcelains. Its traditional formulation comes from an English recipe, consisting of 25% of kaolin, 25% of feldspar and 50% of bovine bone ash. In some studies, this proportion is adapted to regional conditions, optimizing the formulation according to the raw materials available. In this study, the rheological behavior of bone porcelain suspensions, in which the flux feldspar is partially substituted by an alternative flux (espudomenio, wollastonite and glass). The results show that the rheological behavior of porcelain is affected by the size, shape, surface area and particle size distribution of particles in suspension.

  13. 景德镇瓷器款识的历史变迁%THE CHANGES OF HISTORY IN CERAMIC INSCRIPTIONS ON JINGDEZHEN PORCELAIN

    Institute of Scientific and Technical Information of China (English)

    谢志明; 郭小丽; 程坚

    2009-01-01

    With a long-standing history, Jingdezhen porcelain enjoys the world-known reputation. The exquisite inscriptions on it became the historical marks. Reviewing the evolution of porcelain inscriptions of Jingdezhen, the tiny place spectacularly interprets Chinese ceramic events; moreover, witness the porcelain development of the Capital of Porcelain City.%景德镇瓷器历史悠久,世界闻名.一幅幅精美的陶瓷款识铭刻其上,成为历史的标识.回顾景德镇历代瓷器款识,方寸之间,气象万千,演绎着中国陶瓷制造的盛事,也鉴证了瓷都陶瓷发展的历史脉搏.

  14. RESEARCH CHENGCHAO IRON ORE TAILINGS IN PORCELAIN TILE OF APPLICATION%程潮铁尾矿在玻化砖中的应用研究

    Institute of Scientific and Technical Information of China (English)

    石棋; 郭玉忠; 陈井清; 石晓津

    2011-01-01

    Join ChengChao iron ore tailings in the formulation of Porcelain tile, The investigation of the iron ore tailings dosage and the characteristics of the tailings porcelain tile. The results show that. The tailings dosage in porcelain tiles is suitable for 20- 30wt% ~ Tailings porcelain tiles first crystalline phase for calcium feldspar, show to gray black, has good abrasion resistance.%在玻化砖配方中引入程潮铁尾矿,考察了铁尾矿的用量及尾矿玻化砖的特点。结果表明:尾矿在玻化砖中适合的用量为20~30wt%;所制玻化砖的主晶相为钙长石,呈灰黑色,耐磨性优异。

  15. Proteomic comparisons of opaque and transparent variants of Streptococcus pneumoniae by two dimensional-differential gel electrophoresis.

    Science.gov (United States)

    Chai, Melissa H; Weiland, Florian; Harvey, Richard M; Hoffmann, Peter; Ogunniyi, Abiodun D; Paton, James C

    2017-05-26

    Streptococcus pneumoniae (the pneumococcus) is a human pathogen, accounting for massive global morbidity and mortality. Although asymptomatic colonization of the nasopharynx almost invariably precedes disease, the critical determinants enabling pneumococcal progression from this niche to cause invasive disease are poorly understood. One mechanism proposed to be central to this transition involves opacity phase variation, whereby pneumococci harvested from the nasopharynx are typically transparent, while those simultaneously harvested from the blood are opaque. Here, we used two dimensional-differential gel electrophoresis (2D-DIGE) to compare protein expression profiles of transparent and opaque variants of 3 pneumococcal strains, D39 (serotype 2), WCH43 (serotype 4) and WCH16 (serotype 6A) in vitro. One spot comprising a mixture of capsular polysaccharide biosynthesis protein and other proteins was significantly up-regulated in the opaque phenotype in all 3 strains; other proteins were differentially regulated in a strain-specific manner. We conclude that pneumococcal phase variation is a complex and multifactorial process leading to strain-specific pathogenicity.

  16. Phenotypic diversity and correlation between white-opaque switching and the CAI microsatellite locus in Candida albicans.

    Science.gov (United States)

    Hu, Jian; Guan, Guobo; Dai, Yu; Tao, Li; Zhang, Jianzhong; Li, Houmin; Huang, Guanghua

    2016-08-01

    Candida albicans is a commensal fungal pathogen that is often found as part of the human microbial flora. The aim of the present study was to establish a relationship between diverse genotypes and phenotypes of clinical isolates of C. albicans. Totally 231 clinical isolates were collected and used for genotyping and phenotypic switching analysis. Based on the microsatellite locus (CAI) genotyping assay, 65 different genotypes were identified, and some dominant types were found in certain human niches. For example, the genotypes of 30-44 and 30-45 were enriched in vaginal infection samples. C. albicans has a number of morphological forms including the single-celled yeasts, multicellular filaments, white, and opaque cell types. The relationship between the CAI genotype and the ability to undergo phenotypic switching was examined in the clinical isolates. We found that the strains with longer CAA/G repeats in both alleles of the CAI locus were more opaque competent. We also discovered that some MTL heterozygous (a/alpha) isolates could undergo white-opaque switching when grown on regular culture medium (containing glucose as the sole carbon source). Our study establishes a link between phenotypic switching and genotypes of the CAI microsatellite locus in clinical isolates of C. albicans.

  17. In vitro evaluation of the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with composite fillings after cyclic loading

    OpenAIRE

    Sadighpour, Leyla; Geramipanah, Farideh; Allahyari, Somayeh; Fallahi Sichani, Babak; Kharazi Fard, Mohamd Javad

    2014-01-01

    PURPOSE There is insufficient data regarding the durability of porcelain laminate veneers bonded to existing composite fillings. The aim of the present study was to evaluate the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with existing composite fillings. MATERIALS AND METHODS Thirty maxillary central incisors were divided into three groups (for each group, n=10): intact teeth (NP), teeth with class III composite fillings (C3) and teeth with class IV cav...

  18. Shear bond strength of veneering porcelain to zirconia: Effect of surface treatment by CNC-milling and composite layer deposition on zirconia.

    Science.gov (United States)

    Santos, R L P; Silva, F S; Nascimento, R M; Souza, J C M; Motta, F V; Carvalho, O; Henriques, B

    2016-07-01

    The purpose of this study was to evaluate the shear bond strength of veneering feldspathic porcelain to zirconia substrates modified by CNC-milling process or by coating zirconia with a composite interlayer. Four types of zirconia-porcelain interface configurations were tested: RZ - porcelain bonded to rough zirconia substrate (n=16); PZ - porcelain bonded to zirconia substrate with surface holes (n=16); RZI - application of a composite interlayer between the veneering porcelain and the rough zirconia substrate (n=16); PZI - application of a composite interlayer between the porcelain and the zirconia substrate treated by CNC-milling (n=16). The composite interlayer was composed of zirconia particles reinforced porcelain (30%, vol%). The mechanical properties of the ceramic composite have been determined. The shear bond strength test was performed at 0.5mm/min using a universal testing machine. The interfaces of fractured and untested specimens were examined by FEG-SEM/EDS. Data was analyzed with Shapiro-Wilk test to test the assumption of normality. The one-way ANOVA followed by Tukey HSD multiple comparison test was used to compare shear bond strength results (α=0.05). The shear bond strength of PZ (100±15MPa) and RZI (96±11MPa) specimens were higher than that recorded for RZ (control group) specimens (89±15MPa), although not significantly (p>0.05). The highest shear bond strength values were recorded for PZI specimens (138±19MPa), yielding a significant improvement of 55% relative to RZ specimens (p<0.05). This study shows that it is possible to highly enhance the zirconia-porcelain bond strength - even by ~55% - by combining surface holes in zirconia frameworks and the application of a proper ceramic composite interlayer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Interface porcelain tile/PVA modified mortar: a novel nanostructure approach.

    Science.gov (United States)

    Mansur, Alexandra Ancelmo Piscitelli; Mansur, Herman Sander

    2009-02-01

    In ceramic tile systems, the overall result of adherence between porcelain tiles and polymer modified mortars could be explained based on the nano-order structure that is developed at the interface. Based on pull-off tests, Scanning Electron Microscopy images, and Small Angle X-ray Scattering experiments a nanostructured approach for interface tile/PVA modified mortar was built. The increase of adhesion between tile and mortar due to poly(vinyl alcohol), PVA, addition can be explained by the formation of a hybrid ceramic-polymer-ceramic interface by hydrogen bonds between PVA hydroxyl groups and silanol from tile surface and water from nanostructured C-S-H gel interlayer.

  20. The effect of different fluxing agents on the sintering of dry pressed porcelain bodies

    Directory of Open Access Journals (Sweden)

    Radomír Sokolář

    2017-09-01

    Full Text Available The aim of the article is to find the optimal fluxing agent for porcelain body regarding to the possibility of the lowest firing temperature. Sintering behaviour of dry pressed test samples made from the mixture of kaolin and three different types of industrially milled feldspar rocks, bone ash and quartz sand with similar granulometry as dependence of water absorption on the firing temperature was investigated. The most intensive fluxing agent for the sintering is bone ash—the mixture containing bone ash (20wt.% showed sintering temperature 1200 °C. That is about 50 °C lower compared with the most intensive feldspar based fluxing agent—potassium feldspar rock containing 75% of pure microcline.

  1. Effect of various surface treatments on the bond strength of porcelain repair.

    Science.gov (United States)

    Saraç, Duygu; Saraç, Yakup Sinasi; Külünk, Safak; Erkoçak, Ayca

    2013-01-01

    This study evaluated the effect of surface treatments on the repair strength of composite resin on a feldspathic ceramic. Ninety ceramic specimens were divided into six groups. In the experimental groups, 4% hydrofluoric acid etching, Er:YAG laser irradiation, CO2 laser irradiation, airborne-particle abrasion, and silica coating were used as surface treatments. After the application of a porcelain repair kit, composite resin was placed on the treated surfaces. After a shear bond strength test, data were statistically analyzed (α = .05). Surface treatments increased the repair bond strength values (P < .05). Airborne particle abrasion and silica coating were found to be the most effective. CO2 laser showed higher repair strength values than Er:YAG laser.

  2. Crown color match of implant-supported zirconia and Porcelain-Fused-to-Metal restorations:

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2014-01-01

    Objectives: The aim of the present study was to compare the crown color match of implant supported zirconia restorations and Porcelain-Fused-to-Metal (PFM) restorations in anterior maxillary region by spectrophotometric evaluation. Materials and Methods: Eighteen patients with 29 implant......-supported single crowns in anterior maxillary area were recruited, 11 of the implant crowns were zirconia restorations and 18 were PFM restorations. Color match of the implant crown with contra-lateral/neighboring tooth at the position of body 1/3 of the crown were assessed using spectrophotometer (Spectro......ShadeTM, Micro Dental) in CIEL¿a¿b¿ coordinates. Subjective crown color match scores were evaluated. Independent sample t test of SPSS17.0 was used to compare the difference between zirconia restoration and PFM restoration. Spearman correlation was used to analyze the relationship between the spectrophotometric...

  3. Crown color match of implant-supported zirconia and Porcelain-Fused-to-Metal restorations:

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2014-01-01

    Objectives: The aim of the present study was to compare the crown color match of implant supported zirconia restorations and Porcelain-Fused-to-Metal (PFM) restorations in anterior maxillary region by spectrophotometric evaluation. Materials and Methods: Eighteen patients with 29 implant......-supported single crowns in anterior maxillary area were recruited, 11 of the implant crowns were zirconia restorations and 18 were PFM restorations. Color match of the implant crown with contra-lateral/neighboring tooth at the position of body 1/3 of the crown were assessed using spectrophotometer (Spectro......ShadeTM, Micro Dental) in CIEL¿a¿b¿ coordinates. Subjective crown color match scores were evaluated. Independent sample t test of SPSS17.0 was used to compare the difference between zirconia restoration and PFM restoration. Spearman correlation was used to analyze the relationship between the spectrophotometric...

  4. Polyethylene ribbon and fixed orthodontic retention and porcelain veneers: solving an esthetic dilemma.

    Science.gov (United States)

    Iniguez, I; Strassler, H E

    1998-01-01

    The patient, a 58-year-old woman, had started orthodontic treatment to correct spacing between the maxillary anterior teeth 6 year prior to presentation with a chief complaint of tooth discoloration and spacing. The treatment had consisted of the use of a removable appliance to retract the maxillary anterior teeth. The patient continued to wear the appliance sporadically. When she presented, the maxillary incisors were in primary occlusal trauma with Grade 2 mobility. The patient discontinued wearing the appliance. The periodontal condition was addressed with initial therapy. As part of the treatment plan to stabilize the maxillary anterior teeth and provide the patient with an esthetic result, it was decided to do a limited occlusal adjustment of the maxillary anterior teeth to control fremitus, and to place a fixed, composite resin, polyethylene ribbon-reinforced splint, using a facial approach. The esthetic restoration of these teeth was accomplished with bonded porcelain veneers.

  5. Process Development of Porcelain Ceramic Material with Binder Jetting Process for Dental Applications

    Science.gov (United States)

    Miyanaji, Hadi; Zhang, Shanshan; Lassell, Austin; Zandinejad, Amirali; Yang, Li

    2016-03-01

    Custom ceramic structures possess significant potentials in many applications such as dentistry and aerospace where extreme environments are present. Specifically, highly customized geometries with adequate performance are needed for various dental prostheses applications. This paper demonstrates the development of process and post-process parameters for a dental porcelain ceramic material using binder jetting additive manufacturing (AM). Various process parameters such as binder amount, drying power level, drying time and powder spread speed were studied experimentally for their effect on geometrical and mechanical characteristics of green parts. In addition, the effects of sintering and printing parameters on the qualities of the densified ceramic structures were also investigated experimentally. The results provide insights into the process-property relationships for the binder jetting AM process, and some of the challenges of the process that need to be further characterized for the successful adoption of the binder jetting technology in high quality ceramic fabrications are discussed.

  6. Esthetic Rehabilitation of the Smile with No-Prep Porcelain Laminates and Partial Veneers

    Directory of Open Access Journals (Sweden)

    Arcelino Farias-Neto

    2015-01-01

    Full Text Available Rehabilitation of patients with anterior conoid teeth may present a challenge for the clinician, especially when trying to mimic the nature with composite resins. This clinical report exemplifies how a patient with conoid upper lateral incisors was rehabilitated with minimally invasive adhesive restorations. Following diagnostic wax-up and cosmetic mock-up, no-prep veneers and ceramic fragments (partial veneers were constructed with feldspathic porcelain. This restorative material presents excellent reproduction of the optical properties of the dental structure, especially at minimal thicknesses. In this paper, the details about the treatment are described. A very pleasing outcome was achieved, confirming that minimally invasive adhesive restorations are an excellent option for situations in which the dental elements are healthy, and can be modified exclusively by adding material and the patient does not want to suffer any wear on the teeth.

  7. Study and progress of the thermoluminescence dating of the ancient pottery and porcelain

    Institute of Scientific and Technical Information of China (English)

    WANG WeiDa

    2009-01-01

    Two standard methods, the "fine-grain technique" and the "quartz inclusion technique", and a new method, the pre-dose saturation exponential technique in thermoluminescence (TL) dating of ancient pottery and porcelain were reviewed, especially for the measurement of the paleodose and the annual dose. The two standard methods have been acknowledged in domain of TL dating and are used widely for age determination in archaeology and geology. As a dating tool the TL technique has been of great success in authentication of ancient ceramic art objects. However, a few complicated factors limit the precision and accuracy in age determination. These complicated factors are analyzed and discussed. Therefore, although ceramic TL dating can in general solve the problem of authentication of ancient ceramics, there are still complexities that require further research and study.

  8. Study and progress of the thermoluminescence dating of the ancient pottery and porcelain

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Two standard methods,the "fine-grain technique" and the "quartz inclusion technique",and a new method,the pre-dose saturation exponential technique in thermoluminescence(TL)dating of ancient pottery and porcelain were reviewed,especially for the measurement of the paleodose and the annual dose.The two standard methods have been acknowledged in domain of TL dating and are used widely for age determination in archaeology and geology.As a dating tool the TL technique has been of great success in authentication of ancient ceramic art objects.However,a few complicated factors limit the precision and accuracy in age determination.These complicated factors are analyzed and discussed.Therefore,although ceramic TL dating can in general solve the problem of authentication of ancient ceramics,there are still complexities that require further research and study.

  9. Esthetic Rehabilitation of the Smile with No-Prep Porcelain Laminates and Partial Veneers.

    Science.gov (United States)

    Farias-Neto, Arcelino; Gomes, Edna Maria da Cunha Ferreira; Sánchez-Ayala, Alfonso; Sánchez-Ayala, Alejandro; Vilanova, Larissa Soares Reis

    2015-01-01

    Rehabilitation of patients with anterior conoid teeth may present a challenge for the clinician, especially when trying to mimic the nature with composite resins. This clinical report exemplifies how a patient with conoid upper lateral incisors was rehabilitated with minimally invasive adhesive restorations. Following diagnostic wax-up and cosmetic mock-up, no-prep veneers and ceramic fragments (partial veneers) were constructed with feldspathic porcelain. This restorative material presents excellent reproduction of the optical properties of the dental structure, especially at minimal thicknesses. In this paper, the details about the treatment are described. A very pleasing outcome was achieved, confirming that minimally invasive adhesive restorations are an excellent option for situations in which the dental elements are healthy, and can be modified exclusively by adding material and the patient does not want to suffer any wear on the teeth.

  10. 试论钧瓷命名的理念和方法%Ideas and methods of naming Jun porcelain

    Institute of Scientific and Technical Information of China (English)

    李向平

    2012-01-01

    钧瓷在世界陶瓷史上享有独特而崇高的地位,体现着中国人"天人合一"的精神理念。钧瓷命名是以中国传统文化为依据,以艺术审美为手段,以哲学的、宗教的、艺术的语言为载体,将其文化内涵恰当地表示出来,这既是钧瓷营销之必需,又有引领人们发现美、享受美的作用。在多元化的社会背景下,钧瓷的命名不但要求造成产品之间的区别,而且还要凸显其亮点,产生"画龙点睛"、"点石成金"之功效,使人们产生美好的联想,寄予微妙的情趣,获得审美的愉悦。钧瓷命名的理念、方法和技巧体现在钧瓷企业、品牌及产品的命名上。%Jun porcelain has a unique and high status in the world of pottery history, and embodies the Chinese spiritual concept of "harmony between human being and nature". Jun porcelain is named after Chinese traditional culture as the basis, the art aesthetic as the method, the philosophy, religion and artistic language as the carrier, speaking out its cultural connotation properly, which is both essential for jun porcelain marketing and helpful for people to discover and enjoy beauty. In a social background of diversification, the naming of Jun porcelain not only requires to make the difference between products, but also highlights their features, produces the effect of "making the finishing point", so as to to make people produce good associations, expect the subtle appeal and get aesthetic pleasure. The ideas, methods and skills of naming Jun porcelain are reflected by the naming of Jun porcelain enterprises, brands and products.

  11. How will surface treatments affect the translucency of porcelain laminate veneers?

    OpenAIRE

    Turgut, Sedanur; Bagis, Bora; Ayaz, Elif Aydogan; Korkmaz, Fatih Mehmet; Ulusoy, Kıvanç Utku; Bagis, Yildirim Hakan

    2014-01-01

    PURPOSE The purpose of this study was to evaluate whether surface treatments affect the translucency of laminate veneers with different shades and thicknesses. MATERIALS AND METHODS A total of 224 disc-shaped ceramic veneers were prepared from A1, A3, HT (High Translucent) and HO (High Opaque) shades of IPS e.max Press (Ivoclar Vivadent) with 0.5 mm and 1.0 mm thicknesses. The ceramics were divided into four groups for surface treatments. Group C: no surface treatments; Group HF: etched with ...

  12. Porcelain Pillow

    Institute of Scientific and Technical Information of China (English)

    1995-01-01

    This pillow, 7.3cm high, 13.1cm long and 8.1cm wide, was unearthed in Changsha in 1983. Its pedestal is a male lion lying prostrate with an open mouth. The surface is rectangular. The pillow was glazed in blue with brownish green dots. A poem on the surface written with brown ink reads, "Dressed in a red blouse and slik gauze skirt, she

  13. Higher detection sensitivity of anxiolytic effects of diazepam by ledge-free open arm with opaque walled closed arm elevated plus maze in male rats.

    Science.gov (United States)

    Horii, Yasuyuki; Kawaguchi, Maiko

    2015-11-01

    The elevated plus maze (EPM) is an established method for testing animal anxiety. However, EPM apparatuses and their features can differ among laboratories, most notably in the presence/absence of ledges on the open arm and/or the transparency/opaqueness of walls on the closed arm. The combined effects of these variable arm features on EPM behavior are not yet fully understood. In the present study, we prepared four types of EPM apparatus - open arms with (0.5 cm) or without (0 cm) ledges×closed arms with transparent or opaque walls - and compared the maze-exploration behavior of male Sprague-Dawley rats. We found that the presence of open arm ledges significantly increased the incidence of open arm exploration. Furthermore, time spent in the distal segment of the open arm was shortest in the apparatus that had open arms with no ledges and opaque closed arms (No-Ledges/Opaque), and was longest in the apparatus that had open arms with ledges and transparent closed arms (Ledges/Transparent). Additionally, the No-Ledges/Opaque apparatus could detect the effect of 0.5mg/kg diazepam, an anxiolytic drug, whereas the Ledges/Transparent apparatus could not. These results indicate that arm structure (features of both open and closed arms) significantly influences maze-exploratory behavior in rats, and that No-Ledges/Opaque apparatuses have higher detection sensitivity for anxiolytic effects of diazepam than that of Ledges/Transparent apparatuses.

  14. Influence of different silane coupling agents on shear bond strength of metal brackets to porcelain surface%不同偶联剂对烤瓷瓷面与金属托槽抗剪切力的影响

    Institute of Scientific and Technical Information of China (English)

    丁宏

    2015-01-01

    Objective To investigate the influence of different silane coupling agents to the shear bond strength of metal brackets bonded to porcelain surface. Methods 30 porcelain specimens were deglazed by water sandpaper and etched,rinsed with distilled water and dried before applying the silane primer.All specimens were divided randomly into 3 groups according to different silane coupling agents application,every group had 10 porcelain facets.30 metal brackets were bonded to ceramic specimens.All specimens were stored in artificial saliva bath at 37℃ for 24 hours.after brackets bonded for 60min,then the specimens were underwent shear testing with Instron universal testing machine. Results The shear bond strength of the groups treated with silane primer were higher than that without silane primer(P0.05).The groups treated without silane coupling agent showed lower porcelain fracture than the groups treated with silane coupling agent. Conclusions Silane coupling agent can improve the shear bond strength between metal brackets and porcelain surface.There was not any statistically significant in the shear bond strength between the group of one-mix silane coupling agent and the group of two-mix silane coupling agent.%目的:研究不同类型硅烷偶联剂对烤瓷瓷面与金属托槽之间抗剪切力的影响。方法:将30个烤瓷瓷面行水砂纸打磨去釉,HF酸蚀处理,根据硅烷偶联剂的不同随机分3组,将30个金属托槽粘结于烤瓷瓷面,托槽粘结60min后经37℃恒温人工唾液水浴孵化24h,使用Instron万能材料力学试验机测定样本抗剪切力。结果:使用硅烷偶联剂组抗剪切力比未使用硅烷偶联剂组大,差异有统计学意义(P<0.05);单组份和双组份硅烷偶联剂组之间抗剪切力比较,差异无统计学意义(P>0.05);未使用硅烷偶联剂组瓷面破损指数明显小于使用硅烷偶联剂组,差异有统计学意义(P<0.05)。结论:硅烷偶联剂能有

  15. Taguchi design and flower pollination algorithm application to optimize the shrinkage of triaxial porcelain containing palm oil fuel ash

    Science.gov (United States)

    Zainudin, A.; Sia, C. K.; Ong, P.; Narong, O. L. C.; Nor, N. H. M.

    2017-01-01

    In the preparation of triaxial porcelain from Palm Oil Fuel Ash (POFA), a new parameter variable must be determined. The parameters involved are the particle size of POFA, percentage of POFA in triaxial porcelain composition, moulding pressure, sintering temperature and soaking time. Meanwhile, the shrinkage is the dependent variable. The optimization process was investigated using a hybrid Taguchi design and flower pollination algorithm (FPA). The interaction model of shrinkage was derived from regression analysis and found that the shrinkage is highly dependent on the sintering temperature followed by POFA composition, moulding pressure, POFA particle size and soaking time. The interaction between sintering temperature and soaking time highly affects the shrinkage. From the FPA process, targeted shrinkage approaching zero values were predicted for 142 μm particle sizes of POFA, 22.5 wt% of POFA, 3.4 tonne moulding pressure, 948.5 °C sintering temperature and 264 minutes soaking time.

  16. Porcelain gall bladder in a case of papillary renal cell carcinoma: A rare occurrence and its impact on treatment verdict

    Directory of Open Access Journals (Sweden)

    Raghavan V. Sugi Subramaniam

    2012-01-01

    Full Text Available Multiple primary malignant neoplasms (MPMN is a rare clinical entity in which two primary malignancies are encountered in the same individual which can be synchronous (second primary within 6 months or metachronous (beyond 6 months. We present a case of a 41-year-old male who underwent left partial nephrectomy for suspected renal cell carcinoma and it was confirmed based on histopathology. The gallbladder was normal on contrast-enhanced computed tomogram (CECT abdomen. Follow-up CECT done 1 year later showed no enhancing masses in both kidneys, but incidentally porcelain gallbladder was detected. An elective open cholecystectomy was done for acalculous porcelain gall bladder owing to its premalignant nature. We report this case to highlight the relative risk of second primaries in patients treated for primary malignancies and that relevant premalignant conditions should be managed as possible second malignancies to avoid potential complications.

  17. Detection of concealed substances in sealed opaque plastic and coloured glass containers using SORS

    Science.gov (United States)

    Bloomfield, Matthew; Loeffen, Paul W.; Matousek, Pavel

    2010-10-01

    The reliable detection of concealed substances in sealed opaque plastic and coloured glass containers, with low falsealarm rate, is a problem in numerous areas of security. For example, in aviation security, there is no reliable methodology for alarm resolution of substances with high chemical specificity unless the substances are in optically transparent containers. We present a recently developed method called Spatially Offset Raman Spectroscopy (SORS) which enables the discrimination of the Raman spectrum of the content substance from the Raman spectrum of the container material with no prior knowledge of either, thereby allowing unambiguous identification of the container contents. The method is effective with coloured plastic containers that are several millimetres thick and which are not see-through to the eye and also for coloured glass bottles. Such cases do not typically yield to conventional backscatter Raman spectroscopy (or have poor false-alarm rates) since the content signal is often overwhelmed by the signal from the container, which may in addition have a strong interfering fluorescence background. SORS measurement can be performed in a few seconds by shining a laser light onto the container and then measuring the Raman signal at the excitation point but also at one or more offset positions. Each measurement has different relative orthogonal contributions from the container and contents Raman spectra, so that, with no prior knowledge, the pure spectra of both the container and contents can be extracted - either by scaled subtraction or via multivariate statistical methods. The content spectrum can then be compared to a reference library of pure materials to give a threat evaluation with a confidence level not compromised by interfering signals originating from the container wall. In this paper, we describe the methods and their optimization, and characterize their performance in practical screening applications. The study shows that there is

  18. Preliminary assessment of metal-porcelain bonding strength of CoCrW alloy after 3wt.% Cu addition.

    Science.gov (United States)

    Lu, Yanjin; Zhao, Chaoqian; Ren, Ling; Guo, Sai; Gan, Yiliang; Yang, Chunguang; Wu, Songquan; Lin, Junjie; Huang, Tingting; Yang, Ke; Lin, Jinxin

    2016-06-01

    In this work, a novel Cu-bearing CoCrW alloy fabricated by selective laser melting for dental application has been studied. For its successful application, the bonding strength of metal-porcelain is essential to be systematically investigated. Therefore, the aim of this study was to evaluate the metal-porcelain bonding strength of CoCrWCu alloy by three-point bending test, meanwhile the Ni-free CoCrW alloy was used as control. The oxygen content was investigated by an elemental analyzer; X-ray photoelectron spectroscopy (XPS) was used to analyze the surface chemical composition of CoCrW based alloy after preoxidation treatment; the fracture mode was investigated by X-ray energy spectrum analysis (EDS) and scanning electron microscope (SEM). Result from the oxygen content analysis showed that the content of oxygen dramatically increased after the Cu addition. And the XPS suggested that Co-oxidation, Cr2O3, CrO2, WO3, Cu2O and CuO existed on the preoxidated surface of the CoCrWCu alloy; the three-point bending test showed that the bonding strength of the CoCrWCu alloy was 43.32 MPa, which was lower than that of the CoCrW group of 47.65 MPa. However, the average metal-porcelain bonding strength is significantly higher than the minimum value in the ISO 9693 standard. Results from the SEM images and EDS indicated that the fracture mode of CoCrWCu-porcelain was mixed between cohesive and adhesive. Based on the results obtained in this study, it can be indicated that the Cu-bearing CoCrW alloy fabricated by the selective laser melting is a promising candidate for use in dental application.

  19. Fracture resistance of composite resin restorations and porcelain veneers in relation to residual tooth structure in fractured incisors.

    Science.gov (United States)

    Batalocco, Guido; Lee, Heeje; Ercoli, Carlo; Feng, Changyong; Malmstrom, Hans

    2012-02-01

    The aim of the present study was to investigate whether there is a direct correlation between the amount of residual tooth structure in a fractured maxillary incisor and the fracture resistance of composite resin restorations or porcelain veneers after cyclic loading. Sixty human-extracted maxillary central and lateral incisors were mounted in an acrylic block with the coronal aspect of the tooth protruding from the block surface. The teeth were assigned to two groups: 2-mm incisal fracture and 4-mm incisal fracture. Then, the teeth were further divided into two different restoration subgroups, porcelain laminate veneer and composite resin restoration, therefore obtaining four groups for the study (n=15). The specimens were subjected to 1000 cycles of thermocycling and were mechanically tested with a custom-designed cyclic loading apparatus for 2×106 cycles or until they failed. The specimens that survived the cyclic loading were loaded on the incisal edge along the long axis of the tooth with a flat stainless steel applicator until they fractured using a universal testing machine to measure the failure load. Two-way anova was used to assess the significance of restoration, amount of fracture, and interaction effect (α=0.05). During the cyclic loading, for the composite resin group, two specimens with 2-mm fracture and three specimens with 4-mm fracture failed. For the porcelain veneer group, two specimens with 2-mm fracture and one specimen with 4-mm fracture failed. The 2-way anova did not show statistical significance for restoration (P=0.584), amount of fracture (P=0.357), or interaction effect (P=0.212). A composite resin restoration and a porcelain veneer could perform similarly for replacing a fractured incisor edge up to 4mm. Other factors such as esthetic and/or cost would be considerations to indicate one treatment over the other.

  20. Evaluation of shear bond strength of porcelain bonded to laser welded titanium surface and determination of mode of bond failure.

    Science.gov (United States)

    Patil, Narendra P; Dandekar, Minal; Nadiger, Ramesh K; Guttal, Satyabodh S

    2010-09-01

    The aim of this study was to evaluate the shear bond strength of porcelain to laser welded titanium surface and to determine the mode of bond failure through scanning electron microscopy (SEM) and energy dispersive spectrophotometry (EDS). Forty five cast rectangular titanium specimens with the dimension of 10 mm x 8 mm x 1 mm were tested. Thirty specimens had a perforation of 2 mm diameter in the centre. These were randomly divided into Group A and B. The perforations in the Group B specimens were repaired by laser welding using Cp Grade II titanium wire. The remaining 15 specimens were taken as control group. All the test specimens were layered with low fusing porcelain and tested for shear bond strength. The debonded specimens were subjected to SEM and EDS. Data were analysed with 1-way analysis of variance and Student's t-test for comparison among the different groups. One-way analysis of variance (ANOVA) showed no statistically significant difference in shear bond strength values at a 5% level of confidence. The mean shear bond strength values for control group, Group A and B was 8.4 +/- 0.5 Mpa, 8.1 +/- 0.4 Mpa and 8.3 +/- 0.3 Mpa respectively. SEM/EDS analysis of the specimens showed mixed and cohesive type of bond failure. Within the limitations of the study laser welding did not have any effect on the shear bond strength of porcelain bonded to titanium.

  1. The effect of thermal cycling on the shear bond strength of porcelain/Ti-6Al-4V interfaces.

    Science.gov (United States)

    Sendão, Isabel A; Alves, Alexandra C; Galo, Rodrigo; Toptan, Fatih; Silva, Filipe S; Ariza, Edith

    2015-04-01

    The aim of the study was to evaluate the effect of thermal cycling on the shear bond strength of the porcelain/Ti-6Al-4V interfaces prepared by two different processing routes and metallic surface conditions. Polished and SiO2 particle abraded Ti-6Al-4V alloy and Triceram bonder porcelain were used to produce the interfaces. Porcelain-to-metal specimens were processed by conventional furnace firing and hot pressing. Thermal cycling was performed in Fusayama's artificial saliva for 5000 cycles between 5 ± 1 and 60 ± 2°C. After thermal cycling, shear bond tests were carried out by using a custom-made stainless steel apparatus. The results were analyzed using t-Student test and non-parametric Kruskal-Wallis test (p<0.01). Most of the polished-fired specimens were fractured during thermal cycling; thus, it was not possible to obtain the shear bond strength results for this group. Sandblasted-fired, polished-hot pressed, and sandblasted-hot pressed specimens presented the shear bond strength values of 76.2 ± 15.9, 52.2 ± 23.6, and 59.9 ± 22.0 MPa, respectively. Statistical analysis indicated that thermal cycling affected the polished specimens processed by firing, whereas a significant difference was not observed on the other groups.

  2. Evaluation of the Effect of Porcelain Laminate Thickness on Degree of Conversion of Light Cure and Dual Cure Resin Cements Using FTIR

    Science.gov (United States)

    Hoorizad Ganjkar, Maryam; Heshmat, Haleh; Hassan Ahangari, Reza

    2017-01-01

    Statement of the Problem: Increasing the thickness of the veneering porcelain may affect the polymerization of resin cements. Incomplete polymerization of resin cements can lead to compromised quality of restoration and decrease the longevity of indirect restorations. Purpose: This study sought to assess the effect of IPS Empress porcelain thickness on the degree of conversion of light-cure and dual-cure resin cements using Fourier transform infrared spectroscopy. Materials and Method: In this experimental study, IPS Empress porcelain discs (A2 shade) with 10mm diameter and 0.5, 1 and 1.5 mm thicknesses were fabricated. Choice2 (Bisco, USA) and Nexus3 (Kerr, USA) resin cements were light cured through the three porcelain thicknesses in two groups of 3 samples using a LED light-curing unit (LEDemetron II; Kerr, USA). The control group samples were cured individually with no porcelain disc. The degree of conversion of resin cements was determined using FTIR (Bruker; Equinox55, Germany). The data were analyzed using Dunn’s test. Results: The degree of conversion (in percent) beneath the 0.5, 1.5 and 2 mm thicknesses of IPS Empress was 68.67±0.88, 71.06±0.94 and 72.51±0.41 for Choice2 resin cement and 69.60±2.12, 69.64±1.63 and 69.24±2.12 for Nexus3, respectively. Porcelain thickness and type of resin cement had no significant effect on degree of conversion (p≥ 0.05). Conclusion: It seems that increasing the porcelain thickness by up to 1.5 mm has no adverse effect on degree of conversion of both dual cure and light cure resin cements evaluated in this study. PMID:28280757

  3. In Vitro Effect of Porcelain Firing Cycle and Different Thicknesses of IPS E.max CAD Core on Marginal Accuracy of All-Ceramic Restorations

    Directory of Open Access Journals (Sweden)

    Ezatollah Jalalian

    2016-08-01

    Full Text Available Objectives: Marginal adaptation is important for long-term success of full-coverage restorations. The aim of this study was to determine the effect of porcelain firing cycle and different thicknesses of IPS e.max core on marginal accuracy of all-ceramic restorations.Materials and Methods: A standard stainless steel die with 0.8 mm classic chamfer finish line and 10° taper was used in this in vitro study. An impression was taken from the stainless steel die to fabricate 20 epoxy resin dies, which were then scanned and IPS e.max CAD cores were fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM technique in two groups of 10 with  0.7 mm (group A and 0.4mm (group B core thickness. Copings were then placed on their respective dies and randomly numbered. The amount of marginal gap was measured in 10 points under a stereomicroscope (×90 magnification before and after porcelain veneering.Results: The mean gap in 0.7mm and 0.4mm core thicknesses was 15.62±2.55µm and 19.68±3.09µm before porcelain firing and 32.01±3.19µm and 35.24±3.8µm after porcelain firing. The difference in marginal gap between the two thicknesses was significant before porcelain firing but not significant after veneering. Significant differences were also found in the marginal gap before and after porcelain veneering in each group.Conclusion: The porcelain firing cycle increases marginal gap in IPS e.max CAD restorations; 0.3 mm decrease in core thickness slightly increased marginal discrepancy, however it was not significant.

  4. A first principles scanning tunneling potentiometry study of an opaque graphene grain boundary in the ballistic transport regime.

    Science.gov (United States)

    Bevan, Kirk H

    2014-10-17

    We report on a theoretical interpretation of scanning tunneling potentiometry (STP), formulated within the Keldysh non-equilibrium Green's function description of quantum transport. By treating the probe tip as an electron point source/sink, it is shown that this approach provides an intuitive bridge between existing theoretical interpretations of scanning tunneling microscopy and STP. We illustrate this through ballistic transport simulations of the potential drop across an opaque graphene grain boundary, where atomistic features are predicted that might be imaged through high resolution STP measurements. The relationship between the electrochemical potential profile measured and the electrostatic potential drop across such a nanoscale defect is also explored in this model system.

  5. Preliminary assessment of metal-porcelain bonding strength of CoCrW alloy after 3 wt.% Cu addition

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yanjin; Zhao, Chaoqian [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou (China); Ren, Ling [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang (China); Guo, Sai; Gan, Yiliang [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou (China); Yang, Chunguang [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang (China); Wu, Songquan; Lin, Junjie; Huang, Tingting [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou (China); Yang, Ke, E-mail: kyang@imr.ac.cn [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang (China); Lin, Jinxin, E-mail: franklin@fjirsm.ac.cn [Key Laboratory of Optoelectronic Materials Chemistry and Physics, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, 155Yangqiao Road West, Fuzhou (China)

    2016-06-01

    In this work, a novel Cu-bearing CoCrW alloy fabricated by selective laser melting for dental application has been studied. For its successful application, the bonding strength of metal-porcelain is essential to be systematically investigated. Therefore, the aim of this study was to evaluate the metal-porcelain bonding strength of CoCrWCu alloy by three-point bending test, meanwhile the Ni-free CoCrW alloy was used as control. The oxygen content was investigated by an elemental analyzer; X-ray photoelectron spectroscopy (XPS) was used to analyze the surface chemical composition of CoCrW based alloy after preoxidation treatment; the fracture mode was investigated by X-ray energy spectrum analysis (EDS) and scanning electron microscope (SEM). Result from the oxygen content analysis showed that the content of oxygen dramatically increased after the Cu addition. And the XPS suggested that Co-oxidation, Cr{sub 2}O{sub 3}, CrO{sub 2}, WO{sub 3}, Cu{sub 2}O and CuO existed on the preoxidated surface of the CoCrWCu alloy; the three-point bending test showed that the bonding strength of the CoCrWCu alloy was 43.32 MPa, which was lower than that of the CoCrW group of 47.65 MPa. However, the average metal-porcelain bonding strength is significantly higher than the minimum value in the ISO 9693 standard. Results from the SEM images and EDS indicated that the fracture mode of CoCrWCu-porcelain was mixed between cohesive and adhesive. Based on the results obtained in this study, it can be indicated that the Cu-bearing CoCrW alloy fabricated by the selective laser melting is a promising candidate for use in dental application. - Highlights: • The bonding strength of metal-porcelain was slightly decreased with Cu addition; • Cu not only led to promote the diffusion of O and W element but also inhibited the diffusivity of Co in the outward direction; • The changed oxidation behavior resulted in lowering the bonding strength;.

  6. Quantitative crystalline silica exposure assessment for a historical cohort epidemiologic study in the German porcelain industry.

    Science.gov (United States)

    Birk, Thomas; Guldner, Karlheinz; Mundt, Kenneth A; Dahmann, Dirk; Adams, Robert C; Parsons, William

    2010-09-01

    A time-dependent quantitative exposure assessment of silica exposure among nearly 18,000 German porcelain workers was conducted. Results will be used to evaluate exposure-response disease risks. Over 8000 historical industrial hygiene (IH) measurements with original sampling and analysis protocols from 1954-2006 were obtained from the German Berufs- genossenschaft der keramischen-und Glas-Industrie (BGGK) and used to construct a job exposure matrix (JEM). Early measurements from different devices were converted to modern gravimetric equivalent values. Conversion factors were derived from parallel historical measurements and new side-by-side measurements using historical and modern devices in laboratory dust tunnels and active workplace locations. Exposure values were summarized and smoothed using LOESS regression; estimates for early years were derived using backward extrapolation techniques. Employee work histories were merged with JEM values to determine cumulative crystalline silica exposures for cohort members. Average silica concentrations were derived for six primary similar exposure groups (SEGs) for 1938-2006. Over 40% of the cohort accumulated 1 mg/m(3)-years. Nearly 5000 workers had cumulative crystalline silica estimates >1.5 mg/m(3)-years. Similar numbers of men and women fell into each cumulative exposure category, except for 1113 women and 1567 men in the highest category. Over half of those hired before 1960 accumulated >3 mg/m(3)-years crystalline silica compared with 4.9% of those hired after 1960. Among those ever working in the materials preparation area, half accumulated >3 mg/m(3)-year compared with 12% of those never working in this area. Quantitative respirable silica exposures were estimated for each member of this cohort, including employment periods for which sampling used now obsolete technologies. Although individual cumulative exposure estimates ranged from background to about 40 mg/m(3)-years, many of these estimates reflect long

  7. Influence of tab and disk design on shade matching of dental porcelain.

    Science.gov (United States)

    Barrett, Allyson A; Grimaudo, Nicholas J; Anusavice, Kenneth J; Yang, Mark C K

    2002-12-01

    Given the complexity of tooth color, the variations of shade within each tooth, and translucency, it is difficult to view only one small area and select a shade match for restorations. This study tested the effect of specimen design on porcelain shade matching, hypothesizing that flat disks would be matched to one another with more accuracy than tooth-shaped tabs to tabs. All testing was conducted in a Macbeth SpectraLight booth with D65 illumination. Seventy-three senior dental students (25 women and 48 men; mean age, 27 years) were asked to match selected Vita porcelain disks and Vita shade tabs to like specimens. The design order, namely matching tabs or disks first, was alternated for each observer. The specimens were handed to the observer individually. No time limit for matching was imposed, although each observer was given explicit instructions related to the observation and handling of the specimens. Upon completion of the matching exercises, each student received his or her standardized test results and reviewed the matching results. The time for testing and review was approximately 20 minutes per observer. An analysis of variance, with gender and order as 2 factors that could affect matching scores, was performed (P <.05). The mean matching scores were 78.4% for disks and 73.6% for tabs (P=.119). Female observers matched 76.5% of the disks and 77.5% of the tabs, whereas male observers matched 79.4% of the disks and 71.6% of the tabs (P=.054). Matching disks before tabs yielded equivalent levels of shade matching (disks, 77.6%; tabs, 77.1%). When tabs were matched first, the scores were as follows: disks, 79.8%, and tabs, 67.3% (P=.010). Within the limitations of this study, there was no significant difference in shade-matching accuracy between the 2 shapes, although the order of design matching resulted in a difference in shade-matching ability. When tabs were matched first and disks second, improved matching was evident on the second test. The reverse

  8. Spray-dried Powder Granulometry: Influence on the Porous Microstructure of Polished Porcelain Tile

    Directory of Open Access Journals (Sweden)

    Boschi, A. O.

    2010-10-01

    Full Text Available The low porosity of porcelain tile is the result of strict control of the material’s processing conditions (milling of raw materials, compaction and sintering and the characteristics of the raw materials used in its formulation (formation of liquid phases. Sealed pores remaining after the manufacturing process are revealed at the surface after polishing and are the main factor responsible for staining the product. The porous microstructure of the sintered material depends on the characteristics of the porous microstructure of the green compact and on how the densification process evolves during sintering. The present work evaluated how the size distribution of spray-dried granules acts upon the porous microstructure of green compacts and of polished porcelain tile. The results revealed that minor adjustments in the granulometric distribution curve can reduce the visibility of stains on the polished surface, thus improving this property.

    La baja porosidad de los revestimientos porcelánicos, es el resultado del estricto control que se ejerce sobre los distintos parámetros que condicionan el procesamiento de los materiales ( molienda de la materias primas, compactación y sinterización y de las características de las materias primas empleadas en su formulación (formación de fases líquidas. Los poros cerrados que se generan durante la fabricación, y que se abren en la superficie durante el proceso de pulido, son los principales responsables de las manchas que aparecen en la superficie del material. La porosidad microestructural de los materiales sinterizados está condicionada por la porosidad microstrucutural de la pieza en verde y por la evolución del proceso de densificación durante la sinterización. E l trabajo presente evalúa la influencia de la distribución granulométrica del granulado procedente del atomizador sobre la porosidad granulométrica de las piezas en verde y de la pieza ya pulida. Los resultados revelan como

  9. Ultrafast charge separation dynamics in opaque, operational dye-sensitized solar cells revealed by femtosecond diffuse reflectance spectroscopy

    Science.gov (United States)

    Ghadiri, Elham; Zakeeruddin, Shaik M.; Hagfeldt, Anders; Grätzel, Michael; Moser, Jacques-E.

    2016-04-01

    Efficient dye-sensitized solar cells are based on highly diffusive mesoscopic layers that render these devices opaque and unsuitable for ultrafast transient absorption spectroscopy measurements in transmission mode. We developed a novel sub-200 femtosecond time-resolved diffuse reflectance spectroscopy scheme combined with potentiostatic control to study various solar cells in fully operational condition. We studied performance optimized devices based on liquid redox electrolytes and opaque TiO2 films, as well as other morphologies, such as TiO2 fibers and nanotubes. Charge injection from the Z907 dye in all TiO2 morphologies was observed to take place in the sub-200 fs time scale. The kinetics of electron-hole back recombination has features in the picosecond to nanosecond time scale. This observation is significantly different from what was reported in the literature where the electron-hole back recombination for transparent films of small particles is generally accepted to occur on a longer time scale of microseconds. The kinetics of the ultrafast electron injection remained unchanged for voltages between +500 mV and -690 mV, where the injection yield eventually drops steeply. The primary charge separation in Y123 organic dye based devices was clearly slower occurring in two picoseconds and no kinetic component on the shorter femtosecond time scale was recorded.

  10. The efficiency of different light sources to polymerize resin cement beneath porcelain laminate veneers.

    Science.gov (United States)

    Usumez, A; Ozturk, A N; Usumez, S; Ozturk, B

    2004-02-01

    Plasma arc light units for curing resin composites have been introduced with the claim of relatively short curing times. The purpose of this study was to evaluate the efficiency of two different light sources to polymerize dual curing resin cement beneath porcelain laminate veneers. Twenty extracted healthy human maxillary centrals were used. Teeth were sectioned 2 mm below the cemento-enamel junction and crown parts were embedded into self-cure acrylic resin, labial surface facing up. Cavity preparation was carried out on labial surfaces. These teeth were divided into two groups of 10 each. The resin cement/veneer combination was exposed to two different photo polymerization units. A conventional halogen light (Hilux 350, Express Dental Products) and a plasma arc light (Power PAC, ADT) were used to polymerize resin cement. Ten specimens were polymerized conventionally (40 s) and the other specimens by plasma arc curing (PAC) (6 s). Two samples from each tooth measuring 1.2 x 1.2 x 5 mm were prepared. These sections were subjected to microshear testing and failure values were recorded. Statistically significant differences were found between the bond strength of veneers exposed to conventional light and PAC unit (P < 0.001). Samples polymerized with halogen light showed better bond strength. The results of this study suggest that the curing efficiency of PAC through ceramic was lower compared with conventional polymerization for the exposure durations tested in this study.

  11. Investigation of ’chazi’(damaged-enamels)on Chenghua doucai Porcelains

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    At the end of the 1950s,Sun Yingzhou considered that the ’chazi’(damaged colour)on Chenghua doucai imperial porcelain as a defect was originally produced in firing process during Chenghua period(1465―1487).Researchers in China have accepted his view.But any fragment with the ’chazi’ has never been found in several tons of Chenghua imperial sherds excavated from Ming imperial kiln site in Jingdezhen.In China,few scholars have questioned the formation of ’chazi’,and further investigated scientifically.The researchers at the Research Laboratory in the British Museum,employing unde-structive EDXRF,have analyzed the chemical composition of the ’chazi’(damaged colour)on a Chen-ghua doucai stem cup in the museum,and they have confirmed that the ’chazi’(damaged colour)was caused by the fire of the Jianfu palace in the Forbidden City in 1923.Based on their research,the authors studied the colour chemical principle of the ’chazi’s’ formation carefully.According to the ceramic technology principle,scientific reasoning for the ’chazi’ was carried out.With the help of the history of Qing court,the brainteaser of the ’chazi’ was totally uncovered,the misunderstanding for the ’chazi’ has also been corrected.The research also suggests that employing modern science and technology is a direction to study Chinese ancient ceramic further.

  12. LASER-INDUCED BIOACTIVITY IN DENTAL PORCELAIN MODIFIED BY BIOACTIVE GLASS

    Directory of Open Access Journals (Sweden)

    ANASTASIA BEKETOVA

    2012-12-01

    Full Text Available The aim of this study was to investigate the impact of laser-liquid-solid interaction method in the bioactivity of dental porcelain modified by bioactive glass. Forty sol-gel derived specimens were immersed in Dulbecco's Modified Eagle's Medium, 31 and 9 specimens of which were treated with Er:YAG and Nd:YAG laser respectively. Untreated specimens served as controls. Incubation of specimens followed. Bioactivity was evaluated, using Fourier Transform Infrared spectroscopy (FTIR, Scanning Electron Microscopy (SEM/Energy Dispersive Spectroscopy (EDS and Transmission Electron Microscopy (TEM. FTIR detected peaks associated with hydroxyapatite on 1 Nd:YAG- and 4 Er:YAG-treated specimens. SEM analysis revealed that Er:YAG-treated specimens were covered by granular hydroxyapatite layer, while Nd:YAG treated specimen presented growth of flake-like hydroxyapatite. TEM confirmed the results. The untreated controls presented delayed bioactivity. In conclusion, Nd:YAG and Er:YAG laser treatment of the material, under certain fluencies, accelerates hydroxyapatite formation. Nd:YAG laser treatment of specific parameters causes the precipitation of flake-like hydroxyapatite in nano-scale.

  13. Application of laser scanning microscopy in the development of highly abrasion-resistant glazes for fast-fired hard paste porcelain

    Energy Technology Data Exchange (ETDEWEB)

    Pham-Gia, K.; Moertel, H. [Erlangen-Nuernberg Univ., Erlangen (Germany). Lehrstuhl fuer Glas und Keramik; Melchner, R.; Voit, K. [Porzellanfabrik Christian Seltmann GmbH, Weiden (Germany)

    2001-08-01

    To strengthen the competitiveness of porcelain manufacturers in national and international markets with their ever increasing quality requirements, the research presented was aimed at developing highly abrasion-resistant glazes for fast-fired hard paste porcelain. By increasing the degree of cross-linking in the glass structure, it was possible to improve the mechanical abrasion resistance of porcelain glazes. Uniform and defect-free glaze application is particularly important for achieving this improvement. To determine the abrasion resistance of the glazes, a new testing method was developed in which the glaze surface is analysed topographically with a laser scanning microscope before and after defined sand-blasting and the roughness parameters compared. The glaze development work could be minimized with the help of fractional factorial statistical test planning according to the Taguchi method. (orig.)

  14. Influence of Different Power Outputs of Er:YAG Laser on Shear Bond Strength of a Resin Composite to Feldspathic Porcelain

    Directory of Open Access Journals (Sweden)

    Mostafa Sadeghi

    2015-03-01

    Full Text Available Statement of the Problem: Porcelain may fracture or chip if exposed to any trau-mas and can be repaired by using a resin composite. Purpose: This study was aimed to evaluate the influences of Er:YAG laser on shear bond strength (SBS of resin composite to feldspathic porcelain. Materials and Method: Seventy-two porcelain blocks were divided into six groups (n=12: G1: no treatment (control group; G2: 9% hydrofluoric acid (HF; G3-6 were separately irradiated with Er:YAG laser using four energy parameters: 2W, 100mj (G3; 3W, 150mj (G4; 4W, 200mj (G5 and 5W, 250mj (G6, respectively; and 20 Hz frequency in long-pulse mode. After silane treatment, a resin composite rod was bonded to each of the porcelain block. The SBS was measured following storage and thermocycling. Data were analyzed by one-way ANOVA, Tamhane and Chi-Square tests. Results: The highest SBS (12.29±3.04 MPa was obtained with HF (G2. The lowest SBS (2.23±0.60 MPa was observed in G4, followed by G3 (1.96±0.76 MPa. G6 had a significantly higher SBS (8.00±2.22 MPa than other laser irradiation groups. Conclusion: Although, Er:YAG laser irradiation at 5W, 250mJ/20 Hz was effective in promoting adhesion of resin composite to feldspathic porcelain compared with the control group, it cannot be used as a safe alternative method to HF acid. Laser irradiation with the evaluated parameters in this study does not promote an effective adhesion on porcelain surface to create adequate bond for clinical use.

  15. Influence of Different Power Outputs of Er:YAG Laser on Shear Bond Strength of a Resin Composite to Feldspathic Porcelain

    Science.gov (United States)

    Sadeghi, Mostafa; Davari, Abdolrahim; Abolghasami Mahani, Amin; Hakimi, Hamid

    2015-01-01

    Statement of the Problem Porcelain may fracture or chip if exposed to any traumas and can be repaired by using a resin composite. Purpose This study was aimed to evaluate the influences of Er:YAG laser on shear bond strength (SBS) of resin composite to feldspathic porcelain. Materials and Method Seventy-two porcelain blocks were divided into six groups (n=12): G1: no treatment (control group); G2: 9% hydrofluoric acid (HF); G3-6 were separately irradiated with Er:YAG laser using four energy parameters: 2W, 100mj (G3); 3W, 150mj (G4); 4W, 200mj (G5) and 5W, 250mj (G6), respectively; and 20 Hz frequency in long-pulse mode. After silane treatment, a resin composite rod was bonded to each of the porcelain block. The SBS was measured following storage and thermocycling. Data were analyzed by one-way ANOVA, Tamhane and Chi-Square tests. Results The highest SBS (12.29±3.04 MPa) was obtained with HF (G2). The lowest SBS (2.23±0.60 MPa) was observed in G4, followed by G3 (1.96±0.76 MPa). G6 had a significantly higher SBS (8.00±2.22 MPa) than other laser irradiation groups. Conclusion Although, Er:YAG laser irradiation at 5W, 250mJ/20 Hz was effective in promoting adhesion of resin composite to feldspathic porcelain compared with the control group, it cannot be used as a safe alternative method to HF acid. Laser irradiation with the evaluated parameters in this study does not promote an effective adhesion on porcelain surface to create adequate bond for clinical use. PMID:25759855

  16. XPS and electrochemical impedance spectroscopy studies on effects of the porcelain firing process on surface and corrosion properties of two nickel-chromium dental alloys.

    Science.gov (United States)

    Qiu, Jing; Tang, Chun-bo; Zhu, Zhi-jun; Zhou, Guo-xing; Wang, Jie; Yang, Yi; Wang, Guo-ping

    2013-11-01

    The aim of this study was to evaluate the effects of a simulated porcelain firing process on the surface, corrosion behavior and cell culture response of two nickel-chromium (Ni-Cr) dental alloys. A Be-free alloy and a Be-containing alloy were tested. Before porcelain firing, as-cast specimens were examined for surface composition using X-ray photoelectron spectroscopy and metallurgical phases using X-ray diffraction. Corrosion behaviors were evaluated using electrochemical impedance spectroscopy. 3T3 fibroblasts were cultured and exposed indirectly to specimens. MTT assays were counted after 3 and 6 days. The cell culture mediums exposed to specimens were analyzed for metal ion release. After porcelain firing, similar specimens were examined for the same properties. In both as-cast and fired conditions, the Be-free Ni-Cr alloy showed significantly more resistance to corrosion than the Be-containing Ni-Cr alloy, which exhibited BeNi phase. After porcelain firing, the corrosion resistance of the Be-free Ni-Cr alloy decreased statistically, corresponding with evident decreases of Cr and Ni oxides on the alloy surface. Also, the alloy's MTT assay decreased significantly corresponding with an obvious increase of Ni-ion release after the firing. For the Be-containing Ni-Cr alloy, the firing process led to increases of surface oxides and metallic Be, while its corrosion resistance and cell culture response were not significantly changed after porcelain firing. The results suggested that the corrosion resistance and biocompatibility of the Be-free Ni-Cr alloy decreased after porcelain firing, whereas the firing process had little effect on the same properties of the Be-containing Ni-Cr alloy.

  17. Illustration of compositional variations over time of Chinese porcelain glazes combining micro-X-ray Fluorescence spectrometry, multivariate data analysis and Seger formulas

    Energy Technology Data Exchange (ETDEWEB)

    Van Pevenage, J., E-mail: Raman@UGent.be [Department of Analytical Chemistry, Raman Spectroscopy Research Group, Ghent University, Krijgslaan 281, S12, B-9000 Ghent (Belgium); Verhaeven, E. [Department of Conservation and Restoration, University College Antwerp, Blindestraat 9, B-2000 Antwerp (Belgium); Vekemans, B. [Department of Analytical Chemistry, Ghent University, Krijgslaan 281, S12, B-9000 Ghent (Belgium); Lauwers, D., E-mail: Raman@UGent.be [Department of Analytical Chemistry, Raman Spectroscopy Research Group, Ghent University, Krijgslaan 281, S12, B-9000 Ghent (Belgium); Herremans, D.; De Clercq, W. [Department of Archaeology, Ghent University, Sint-Pietersnieuwstraat 35, B-9000 Ghent (Belgium); Vincze, L. [Department of Analytical Chemistry, Ghent University, Krijgslaan 281, S12, B-9000 Ghent (Belgium); Moens, L., E-mail: Raman@UGent.be [Department of Analytical Chemistry, Raman Spectroscopy Research Group, Ghent University, Krijgslaan 281, S12, B-9000 Ghent (Belgium); Vandenabeele, P. [Department of Archaeology, Ghent University, Sint-Pietersnieuwstraat 35, B-9000 Ghent (Belgium)

    2015-01-01

    In this research, the transparent glaze layers of Chinese porcelain samples were investigated. Depending on the production period, these samples can be divided into two groups: the samples of group A dating from the Kangxi period (1661–1722), and the samples of group B produced under emperor Qianlong (1735–1795). Due to the specific sample preparation method and the small spot size of the X-ray beam, investigation of the transparent glaze layers is enabled. Despite the many existing research papers about glaze investigations of ceramics and/or porcelain ware, this research reveals new insights into the glaze composition and structure of Chinese porcelain samples. In this paper it is demonstrated, using micro-X-ray Fluorescence (μ-XRF) spectrometry, multivariate data analysis and statistical analysis (Hotelling's T-Square test) that the transparent glaze layers of the samples of groups A and B are significantly different (95% confidence level). Calculation of the Seger formulas, enabled classification of the glazes. Combining all the information, the difference in composition of the Chinese porcelain glazes of the Kangxi period and the Qianlong period can be demonstrated. - Highlights: • Fully described methodology for the analysis of silicate glazes of Chinese porcelain samples • The combination of a semi-quantitative analysis of silicate glazes, multi-variate data and statistical analysis. • The use of Seger formula to understand better the composition of the glazes. • New insights into the glaze composition and structure of Chinese porcelain glazes of different time periods.

  18. A comparative transmission electron microscopy, energy dispersive x-ray spectroscopy and spatially resolved micropillar compression study of the yttria partially stabilised zirconia - porcelain interface in dental prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Lunt, Alexander J.G., E-mail: alexander.lunt@chch.ox.ac.uk [Department of Engineering Science, University of Oxford, Parks Road, Oxford, Oxfordshire OX1 3PJ (United Kingdom); Mohanty, Gaurav, E-mail: gaurav.mohanty@empa.ch [EMPA Materials Science & Technology, Feuerwerkerstrasse 39, CH-3602 Thun (Switzerland); Ying, Siqi, E-mail: siqi.ying@eng.ox.ac.uk [Department of Engineering Science, University of Oxford, Parks Road, Oxford, Oxfordshire OX1 3PJ (United Kingdom); Dluhoš, Jiří, E-mail: jiri.dluhos@tescan.cz [TESCAN Brno, s.r.o., Libušina tř. 1, 623 00 Brno-Kohoutovice (Czech Republic); Sui, Tan, E-mail: tan.sui@eng.ox.ac.uk [Department of Engineering Science, University of Oxford, Parks Road, Oxford, Oxfordshire OX1 3PJ (United Kingdom); Neo, Tee K., E-mail: neophyte@singnet.com.sg [Specialist Dental Group, Mount Elizabeth Orchard, 3 Mount Elizabeth, #08-03/08-08/08-10, 228510 (Singapore); Michler, Johann, E-mail: johann.michler@empa.ch [EMPA Materials Science & Technology, Feuerwerkerstrasse 39, CH-3602 Thun (Switzerland); Korsunsky, Alexander M., E-mail: alexander.korsunsky@eng.ox.ac.uk [Department of Engineering Science, University of Oxford, Parks Road, Oxford, Oxfordshire OX1 3PJ (United Kingdom)

    2015-12-01

    Recent studies into the origins of failure of yttria partially stabilised zirconia–porcelain veneered prosthesis have revealed the importance of micro-to-nano scale characterisation of this interface zone. Current understanding suggests that the heat treatment, residual stresses and varying microstructure at this location may contribute to near-interface porcelain chipping. In this study the chemical, microstructural and mechanical property variation across the interfacial zone has been characterised at two differing length scales and using three independent techniques; energy dispersive X-ray spectroscopy, transmission electron microscopy and micropillar compression. Energy dispersive X-ray spectroscopy mapping of the near-interface region revealed, for the first time, that the diffusional lengths of twelve principal elements are limited to within 2–6 μm of the interface. This study also revealed that 0.2–2 μm diameter zirconia grains had become detached from the bulk and were embedded in the near-interface porcelain. Transmission electron microscopy analysis demonstrated the presence of nanoscale spherical features, indicative of tensile creep induced voiding, within the first 0.4–1.5 μm from the interface. Within zirconia, variations in grain size and atomistic structure were also observed within the 3 μm closest to the interface. Micropillar compression was performed over a 100 μm range on either side of the interface at the spatial resolution of 5 μm. This revealed an increase in zirconia and porcelain loading modulus at close proximities (< 5 μm) to the interface and a decrease in zirconia modulus at distances between 6 and 41 μm from this location. The combination of the three experimental techniques has revealed intricate details of the microstructural, chemical and consequently mechanical heterogeneities in the YPSZ–porcelain interface, and demonstrated that the length scales typically associated with this behaviour are approximately ± 5

  19. 中国古代南方白瓷的组成特征研究%Research on the Composition Characteristics of Chinese Ancient Southern White Porcelain

    Institute of Scientific and Technical Information of China (English)

    吴隽; 叶正隆; 吴军明; 张茂林; 李其江; 王丽丽; 江鹏飞

    2012-01-01

    The southern white porcelain is the rise in our country's pottery, it is later than the development of northern white porcelain, but it is rising stars, blockbuster, well-grounded, keeping continuous. Jingdezhen kiln and Dehua kiln are the most representative kilns among the southern white porcelain kilns, the present paper used EDXRF to test 30 pieces of Song, Yuan and Ming period' Dehua white porcelains and Jingdezhen Yuan dynasty Shufu white porcelains samples to analyze the different characteristics of the bodies and the glaze of these samples in terms of time and space. The results show that in the bodies and the glaze of Jingdezhen Shufu white porcelains the iron content is obviously on the high side, and the Dehua white porcelains' potassium content is obviously on the high side, and along with time development they have been in a rising trend, which should be the main reason for the sudden rise of Dehua white porcelain sculptures.%景德镇窑和德化窑是南方白釉瓷窑口中最具有代表性的两个窑口.该文利用能量色散X射线荧光光谱分析仪,对30件宋、元、明时期的德化白瓷以及元代景德镇枢府白瓷样品进行了测试,并从时空角度对比分析了不同白瓷样品胎釉的组成特征.结果表明,景德镇枢府白瓷胎釉组成铁含量均明显偏高,而德化白瓷胎釉组成中的钾含量均明显偏高,且随着时间发展具有上升趋势,这应是德化雕塑白瓷异军突起的主要原因.

  20. Clinical evaluation on porcelain laminate veneers bonded with light-cured composite: results up to 7 years.

    Science.gov (United States)

    D'Arcangelo, Camillo; De Angelis, Francesco; Vadini, Mirco; D'Amario, Maurizio

    2012-08-01

    The purpose of this study was to evaluate the clinical performance of laminate porcelain veneers bonded with a light-cured composite. Thirty patients were restored with 119 porcelain laminate veneers. The veneers were studied for an observation time of 7 years. Marginal adaptation, marginal discoloration, secondary caries, color match, and anatomic form were clinically examined following modified United States Public Health Service (USPHS) criteria. Each restoration was also examined for cracks, fractures, and debonding. Pulp vitality was verified. In addition, plaque and gingival indexes and increase in gingival recession were recorded. Survival rate evaluating absolute failures and success rate describing relative failures were statistically determined, using both restoration and patient-related analyses. On the basis of the criteria used, most of the veneers rated Alfa. After 7 years, the results of the clinical investigation regarding marginal adaptation and marginal discoloration revealed only 2.5% and 4.2% Bravo ratings, respectively, among the 119 initially placed veneers. Using the restoration as the statistical unit, the survival rate was 97.5%, with a high estimated success probability of 0.843 after 7 years. Using the patient as the statistical unit, the survival rate was 90.0% and the estimated success probability after 7 years was 0.824. Gingival response to the veneers was all in the satisfactory range. Porcelain laminate veneers offer a predictable and successful treatment modality giving a maximum preservation of sound tooth. The preparation, cementation, and finishing procedures adopted are considered key factors for the long-term success and aesthetical result of the veneer restorations.

  1. A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain

    Science.gov (United States)

    Jung, Yu-Seok; Lee, Jae-Whang; Choi, Yeon-Jo; Ahn, Jin-Soo; Shin, Sang-Wan

    2010-01-01

    PURPOSE This study was conducted to evaluate clinical validity of a zirconia full-coverage crown by comparing zirconia's wear capacity over antagonistic teeth with that of feldspathic dental porcelain. MATERIALS AND METHODS The subject groups were divided into three groups: the polished feldspathic dental porcelain group (Group 1), the polished zirconia group (Group 2), and the polished zirconia with glazing group (Group 3). Twenty specimens were prepared from each group. Each procedure such as plasticity, condensation, and glazing was conducted according to the manufacturer's manual. A wear test was conducted with 240,000 chewing cycles using a dual-axis chewing simulator. The degree of wear of the antagonistic teeth was calculated by measuring the volume loss using a three-dimensional profiling system and ANSUR 3D software. The statistical significance of the measured degree of wear was tested with a significant level of 5% using one-way ANOVA and the Tukey test. RESULTS The degrees of wear of the antagonistic teeth were 0.119 ± 0.059 mm3 in Group 1, 0.078 ± 0.063 mm3 in Group 3, and 0.031 ± 0.033 mm3 in Group 2. Statistical significance was found between Group 1 and Groups 2 and between Group 2 and 3, whereas no statistical significance was found between Group 1 and Group 3. CONCLUSION Despite the limitations of this study on the evaluation of antagonistic teeth wear, the degree of antagonistic tooth wear was less in zirconia than feldspathic dental porcelain, representing that the zirconia may be more beneficial in terms of antagonistic tooth wear. PMID:21165280

  2. Evaluation of the effect of polishing on flexural strength of feldspathic porcelain and its comparison with autoglazing and over glazing

    Directory of Open Access Journals (Sweden)

    Jalali H.

    2005-06-01

    Full Text Available Statement of Problem: Ceramic restorations are popular because they can provide the most natural replacement for teeth. However, the brittleness of ceramics is a primary disadvantage. There are various methods for strengthening ceramics such as metal framework, ceramic cores, and surface strengthening mechanisms through glazing, work hardening and ion exchange. Purpose: The purpose of this study was to evaluate the effect of polish on flexural strength of feldspathic porcelain and to compare it with overglaze and autoglaze. Materials and Methods: In this experimental study, one brand of feldspathic porcelain (colorlogic, Ceramco was used and forty bars (25×6×3 mm were prepared according to ISO 6872 and ADA No. 69. The specimens were randomly divided into four groups: overglazed, auto glazed, fine polish and coarse polish (clinic polish. Flexural strength of each specimen was determined by three point bending test (Universal Testing Machine, Zwick 1494, Germany. Collected data was analyzed by ANOVA and post-hoc test with P<0.05 as the limit of significance. Results: A significant difference was observed among the studied groups (P<0.0001. According to post-hoc test, flexural strength in overglaze and fine polish group were significantly stronger than clinic polish and autoglaze group (P<0.001. Although the mean value for overglazed group was higher than fine polish group, this was not statistically significant (P=0.9. Also no statistical difference was seen between autoglazed and coarse polish group (P=0.2. Conclusion: Based on the findings of this study, flexural strength achieved by fine polish (used in this study can compete with overglazing the feldespathic porcelains. It also can be concluded that a final finishing procedure that involves fine polishing may be preferred to simple staining followed by self-glazing.

  3. Interfacial characterization of ceramic core materials with veneering porcelain for all-ceramic bi-layered restorative systems.

    Science.gov (United States)

    Tagmatarchis, Alexander; Tripodakis, Aris-Petros; Filippatos, Gerasimos; Zinelis, Spiros; Eliades, George

    2014-01-01

    The aim of the study was to characterize the elemental distribution at the interface between all-ceramic core and veneering porcelain materials. Three groups of all-ceramic cores were selected: A) Glass-ceramics (Cergo, IPS Empress, IPS Empress 2, e-max Press, Finesse); B) Glass-infiltrated ceramics (Celay Alumina, Celay Zirconia) and C) Densely sintered ceramics (Cercon, Procera Alumina, ZirCAD, Noritake Zirconia). The cores were combined with compatible veneering porcelains and three flat square test specimens were produced for each system. The core-veneer interfaces were examined by scanning electron microscopy and energy dispersive x-ray microanalysis. The glass-ceramic systems showed interfacial zones reach in Si and O, with the presence of K, Ca, Al in core and Ca, Ce, Na, Mg or Al in veneer material, depending on the system tested. IPS Empress and IPS Empress 2 demonstrated distinct transitional phases at the core-veneer interface. In the glassinfiltrated systems, intermixing of core (Ce, La) with veneer (Na, Si) elements occurred, whereas an abrupt drop of the core-veneer elemental concentration was documented at the interfaces of all densely sintered ceramics. The results of the study provided no evidence of elemental interdiffusion at the core-veneer interfaces in densely sintered ceramics, which implies lack of primary chemical bonding. For the glass-containing systems (glassceramics and glass-infiltrated ceramics) interdiffusion of the glass-phase seems to play a critical role in establishing a primary bonding condition between ceramic core and veneering porcelain.

  4. The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns

    Directory of Open Access Journals (Sweden)

    Reza Derafshi

    2015-03-01

    Full Text Available Statement of the Problem: One disadvantage of cement-retained crowns is the lack of predictable irretrievability. This problem can be overcome through designing a screw access hole in the metal substructure of cement-retained restora-tion and using porcelain stain to define this area. Purpose: This study aimed to evaluate the influence of existence of screw access hole on porcelain fracture resistance of metal-ceramic implant-supported crowns. Materials and Method: Thirty six standardized metal-ceramic crowns were fabri-cated and divided into 3 groups (n=12; group 1 conventional cement-retained metal-ceramic crowns as control group, group 2 cement-retained MC crowns in which porcelain stain was used to define the location of screw access channel, and group 3 cement-retained metal-ceramic crowns in the metal substructure of which a hole and ledge was designed in the location of screw access channel. The specimens were cemented (TempBond, Kerr to their dedicated abutments. A hole was made in the location of screw access channel in group 2 and 3 and filled with photo-polymerized composite resin (3M; ESPE. All specimens were thermocycled and loaded in universal testing machine at crosshead speed of 2mm/min until fracture. Mean values of load at fracture were calculated in each group and compared with One-way ANOVA (α=0.05. Results: Mean value of the load required to fracture the restorations was 1947±487 N in group 1, 1927±539 N in group 2, and 2170±738 N in group 3. No statistically significant difference was found between the fracture resistance values of the three groups (p> 0.05 Conclusion: Presence of screw access channel in cement-retained implant restora-tions does not compromise fracture resistance.

  5. Effect of sintering gold paste coating on the bonding strength of pure titanium and three low-fusing porcelains%涂覆烧结金膏处理对三种钛瓷粉与纯钛结合强度的影响

    Institute of Scientific and Technical Information of China (English)

    张亚丽; 骆小平; 周黎

    2012-01-01

    Objective To study the effect of sintering gold paste coating of pure titanium on the adhesion of three porcelains following the protocol ISO 9693,and to investigate the titanium-porcelains interfaces.Methods Sixty machined pure titanium samples were prepared in a rectangular shape according to ISO 9693 and divided equally into six groups.Half of the strips were coated with gold paste (Deckgold)and sintered. Three ultra-low-fusing dental porcelains ( I:Initial Ti,S:Super porcelain Ti-22,T:TitanKeramik) were fused onto the titanium surfaces.A thin layer of bonding agent was only applied on the surfaces of uncoated gold specimens.The interface of the porcelain and titanium was observed with a field emission scanning electron microscope (FE-SEM) after metallographic preparation and sputtered with a very thin carbon layer of the embedded titanium-porcelain interface.After three-point bending test was performed,optical stereomicroscope was used to characterize the titanium-porcelains adhesion and determine the mode of failure.Results FE-SEM illustrated intermetallic compounds of Au-Ti formed with some visible microcracks in the gold layer and the interface of gold layer and ceramic.All the uncoated gold titanium-porcelain system showed predominately adhesive fracture at the titanium oxidation,whereas the failure modes in all gold coated systems were cohesive and adhesive,mainly cohesive.The three-point-bending test showed that the bonding strength of GS and GI groups [ (37.08 ± 4.32 ) and (36.20 ± 2.40 ) MPa ] were higher than those in uncoated groups[ (31.56 ± 3.74) and (30.88 ± 2.60) M P a,P < 0.05 ],while no significant difference was found between T group and GT group ( P> 0.05 ).Conclusions The gold paste intermediate coatings can improve bond strengths of Super porcelain Ti-22 system and Initial Ti system,which have potential applications in clinical fields.%目的 探讨纯钛表面金膏涂覆烧结处理对3种钛瓷粉与纯

  6. Effect of four different surface treatments on shear bond strength of three porcelain repair systems: An in vitro study

    Directory of Open Access Journals (Sweden)

    Ritesh Gourav

    2013-01-01

    Full Text Available Background: Ceramic fracture in metal ceramic restorations are serious and pose an aesthetic and functional dilemma both for the patients and the dentist. This has created a demand for the development of practical repair options which do not necessitate the removal and remake of entire restorations. Aim: To evaluate and compare the effect of four different surface treatments on shear bond strength of metal ceramic specimens with three commercially available porcelain repair systems. Materials and Methods: Specimens were fabricated with a base-metal ceramic alloy and divided into three groups, to evaluate three porcelain repair systems. Each group was divided into four subgroups based on surface treatment (A sandblasting, (B sandblasting followed by etching with 9% HF (Hydrofluoric acid on surrounding ceramic, (C Use of a diamond bur on exposed metal followed by etching with 37% H 3 PO 4 and (D Control groups (D 1 , D 2 , D 3 for three groups of porcelain repair system which was not subjected to further treatment after finishing with 240 grit silicon carbide paper grinding. Shear bond strength of each group of specimens based on surface treatment were evaluated with a universal testing machine after storing in distilled water for 7 days. One way ANOVA and Tukey-HSD procedure were used to compare the mean values between and among the groups. Results: The mean shear bond strength of group III (10.402 ± 1.055 were significantly higher than group I (8.647 ± 0.990 and group II (8.099 ± 0.600 for all surface treatments. However the mean values of shear bond strength of sub-group A were significantly higher than sub-group C and D but were not significantly higher than sub-group B. Conclusion: The results of this study suggest that in fractured metal ceramic restorations the exposed metal surface treated with sandblasting or sandblasting and etching the surrounding ceramic surface with HF can increase the shear bond strength of the repaired metal

  7. Shear bond strength of metal brackets to feldspathic porcelain treated by Nd:YAG laser and hydrofluoric acid.

    Science.gov (United States)

    Hosseini, Mohammad Hashem; Sobouti, Farhad; Etemadi, Ardavan; Chiniforush, Nasim; Shariati, Mahsa

    2015-02-01

    Adult orthodontic treatment requires bonding orthodontic attachment to dental restorations. Ceramics are commonly used as esthetic restorative materials for the crowns and bridges. The present study evaluated the shear bond strength of metal orthodontic brackets to the feldspathic porcelain surfaces following conditioning by different powers of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser and hydrofluoric acid as a conventional method. Seventy-two glazed porcelain samples were prepared and randomly attributed to six equal groups of 12. In the conventional hydrofluoric (HF) group, the specimens were etched by 9.6% hydrofluoric acid for 4 min. In laser groups, samples were conditioned by 0.75-, 1-, 1.25-, 1.5-, and 2-W Nd:YAG laser for 10 s. Metal brackets were bonded to porcelain samples and after being stored in distilled water for 24 h, they were subjected to thermocycling for 500 cycles. The debonding was carried out by a Zwick testing machine. The data were statistically analyzed by ANOVA and Tamhane multiple comparisons tests. The mean ± SD of the shear bond strength in the laser group 0.75, 1, 1.25, 1.5, and 2 W and HF group was 2.2 ± 0.9, 4.2 ± 1.1, 4.9 ± 2.4, 7 ± 1.7, 9.6 ± 2.7, and 9.4 ± 2.5, respectively. Together with the increased power of laser, the mean shear bond strength was increased continuously and no significant differences were found between the HF group and the laser groups with power of 1.5 or 2 W. Also, there was no significant difference between all test groups in ARI scores. There was no significant difference between bond strength of laser groups with power of 1.5 and 2 W and HF-etched group. So, Nd:YAG laser with appropriate parameters can be used as an alternative method for porcelain etching.

  8. Digital Smile Design concept delineates the final potential result of crown lengthening and porcelain veneers to correct a gummy smile.

    Science.gov (United States)

    Trushkowsky, Richard; Arias, David Montalvo; David, Steven

    2016-01-01

    Prior to initiating any treatment, it is necessary to visualize the desired outcomes. It then becomes possible to formulate the steps required to achieve this result. Digital Smile Design (DSD) utilizes patient input and information gathered through diagnostic procedures to create an esthetic treatment scheme. In the case presented here, the NYUCD Esthetic Evaluation Form, intraoral and extraoral photographs, mounted diagnostic casts, physical examination, and radiographs were the diagnostic modalities. The gathered information served as a starting point for a wax-up and intraoral mock-up. This case report demonstrates how the DSD served as a template for crown lengthening procedures and design of the final porcelain veneer restorations.

  9. 中国瓷质砖发展趋势分析%Analysis of development trend of Chinese porcelain tile

    Institute of Scientific and Technical Information of China (English)

    黄惠宁

    2009-01-01

    本文定性和半定量对中国抛光砖与瓷质有釉砖(glazed porcelain tile-中国人俗称"仿古砖"rustic tile)进行了分析对比,结论是中国现阶段瓷质抛光砖强,而瓷质有釉砖弱,但是中国瓷质有釉砖正处于快速发展的阶段,中国瓷质有釉砖的未来是美好的!

  10. Avaliação da superfície da porcelana após a descolagem de braquetes ortodônticos Porcelain surface evaluation after debonding of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    André Moreira Mattos

    2006-10-01

    Full Text Available OBJETIVO: o objetivo deste trabalho foi avaliar a influência do tempo de condicionamento ácido em superfície de porcelana e o estado desta após a descolagem de braquetes ortodônticos. METODOLOGIA: foram utilizadas 20 amostras de porcelana feldspática para esmalte (Duceram-LFC divididas em 2 grupos de acordo com o tempo de condicionamento com ácido fluorídico 10% (15 segundos e 1 minuto. Após o ataque ácido, foi aplicado silano (3M Scotchbond, adesivo resinoso (Optibond Solo Plus e resina (Fill Magic nestas superfícies. A descolagem foi realizada através de força de cisalhamento numa máquina universal de ensaios (DL 500 - EMIC calibrada com velocidade fixa de 0,5mm/minuto. O índice do adesivo remanescente (ARI nas superfícies cerâmicas e o estado destas após a remoção dos braquetes foram avaliados através de fotos digitais. RESULTADOS: no grupo 15 segundos, a força de adesão média foi de 3,63MPa, significantemente inferior à do grupo 1 minuto, que foi de 7,18MPa (pAIM: the aim of this study was to evaluate the influence of acid conditioning time in porcelain surface and its characteristics after debonding of orthodontic brackets. METHODS: twenty samples of feldspathic porcelain for enamel (Duceram-LFC were divided in 2 groups according with the amount of time of acid conditioning with hydrofluoric acid 10% (15 seconds and 1 minute. After acid etching, it was applied silane (3M Scotchbond, adhesive (Optibond Solo Plus and resin (Fill Magic in these surfaces. The debonding was done with shear strength through a universal testing machine (DL 500 - EMIC calibrated with a fixed speed of 0.5mm/minute. The adhesive remnant index (ARI in the porcelain surfaces and their characteristics after removal of the brackets were evaluated through digital pictures. RESULTS: in the 15 seconds group, the mean bond strength was 3.63Mpa, significantly lower than the 1 minute group, that was 7.18Mpa (p<0.0001. All fractures during debonding

  11. 云纹干涉法测量不同载荷条件下金属-瓷标本的位移%Application of moiré interferometry method in measurement of displacement of metal-porcelain restorations

    Institute of Scientific and Technical Information of China (English)

    米红林

    2011-01-01

    BACKGROUND: Moiré interferometry method which belongs to the range of experiment mechanics is a modern photo-mechanics test technique. On the other hand, metal-porcelain restorations characterized as beautiful, compatible and stable properties are widely used in oral medicine domain. Moiré interferometry technique is applied in the oral restoration and some mechanics data can be obtained. It can be realized in discipline complementation and interaction between mechanics and bio-medicine engineering. OBJECTIVE: To introduce the moiré interferometry technique in details, and to study the displacement of metal-porcelain restorations under different loads by using the moiré interferometry technique as it is found that porcelains often flake off from the base of restorations in oral clinic. METHODS: The horizontal and vertical displacement of metal-porcelain restorations were measured by using the moiré interferometry method which is sensitive and easy to operate, and suitable for in-plane displacement measurement. The displacement was shown in the form of interferometry patterns. RESULTS and CONCLUSION: The interferometry patterns which represented the in-plane displacement of specimens were obtained and the displacement was linearly related with the loading changes. Moiré interferometry method can be used in measuring the displacement of restorations. Operation is simple and results are shown by interferometry patterns.%背景:云纹干涉法是现代光力学测试技术,是实验力学范畴.另外,金瓷修复体以其较好的生物相容性,色泽美观,坚固而广泛应用于临床,将云纹干涉技术应用口腔领域得到医学工程中所需位移量,体现学科交叉,较好的实现学科互补.目的:详细介绍了云纹干涉法原理以及试件栅的复制,针对临床经常发现口腔中瓷剥落等破坏行为,应用云纹干涉法来研究金瓷复合材料受力后的位移量.方法:采用云纹干涉技术测试金瓷试件在不同

  12. Estimating nocturnal opaque ice cloud optical depth from MODIS multispectral infrared radiances using a neural network method

    Science.gov (United States)

    Minnis, Patrick; Hong, Gang; Sun-Mack, Szedung; Smith, William L.; Chen, Yan; Miller, Steven D.

    2016-05-01

    Retrieval of ice cloud properties using IR measurements has a distinct advantage over the visible and near-IR techniques by providing consistent monitoring regardless of solar illumination conditions. Historically, the IR bands at 3.7, 6.7, 11.0, and 12.0 µm have been used to infer ice cloud parameters by various methods, but the reliable retrieval of ice cloud optical depth τ is limited to nonopaque cirrus with τ water path in the future. Factors affecting the uncertainties and potential improvements are discussed. With improved techniques for discriminating between opaque and semitransparent ice clouds, the method can ultimately improve cloud property monitoring over the entire diurnal cycle.

  13. Predicting Reading and Spelling Difficulties in Transparent and Opaque Orthographies: A Comparison between Scandinavian and U.S./Australian Children

    Science.gov (United States)

    Furnes, Bjarte; Samuelsson, Stefan

    2010-01-01

    In this study, predictors of reading and spelling difficulties among children learning more transparent (Norwegian/Swedish) and less transparent (English) orthographies were examined longitudinally from preschool through Grade 2 using parallel versions of tests. A series of logistic regression analysis indicated three main findings. First, phonological awareness as a predictor of reading difficulties in the Scandinavian sample was time-limited to Grade 1, but remained as a significant predictor in the English-speaking sample. Second, phonological awareness predicted spelling difficulties similarly across orthographies. Third, preschool and kindergarten RAN was a significant predictor of reading and spelling difficulties at both Grades 1 and 2 across orthographies. The authors conclude that phonological awareness diminishes as a predictor of reading difficulties in transparent orthographies after the first years of schooling, that RAN is a better long term predictor of reading difficulties, and that phonological awareness is associated with spelling difficulties similarly in transparent and opaque orthographies. PMID:20440743

  14. Evaluation of Microflow Digital Imaging Particle Analysis for Sub-Visible Particles Formulated with an Opaque Vaccine Adjuvant.

    Science.gov (United States)

    Frahm, Grant E; Pochopsky, Alex W T; Clarke, Tessa M; Johnston, Michael J W

    2016-01-01

    Microflow digital imaging (MDI) has become a widely accepted method for assessing sub-visible particles in pharmaceutical formulations however, to date; no data have been presented on the utility of this methodology when formulations include opaque vaccine adjuvants. This study evaluates the ability of MDI to assess sub-visible particles under these conditions. A Fluid Imaging Technologies Inc. FlowCAM® instrument was used to assess a number of sub-visible particle types in solution with increasing concentrations of AddaVax™, a nanoscale squalene-based adjuvant. With the objective (10X) used and the limitations of the sensor resolution, the instrument was incapable of distinguishing between sub-visible particles and AddaVax™ droplets at particle sizes less than 5 μm. The instrument was capable of imaging all particle types assessed (polystyrene beads, borosilicate glass, cellulose, polyethylene protein aggregate mimics, and lysozyme protein aggregates) at sizes greater than 5 μm in concentrations of AddaVax™ up to 50% (vol:vol). Reduced edge gradients and a decrease in measured particle sizes were noted as adjuvant concentrations increased. No significant changes in particle counts were observed for polystyrene particle standards and lysozyme protein aggregates, however significant reductions in particle counts were observed for borosilicate (80% of original) and cellulose (92% of original) particles. This reduction in particle counts may be due to the opaque adjuvant masking translucent particles present in borosilicate and cellulose samples. Although the results suggest that the utility of MDI for assessing sub-visible particles in high concentrations of adjuvant may be highly dependent on particle morphology, we believe that further investigation of this methodology to assess sub-visible particles in challenging formulations is warranted.

  15. Evaluation of Microflow Digital Imaging Particle Analysis for Sub-Visible Particles Formulated with an Opaque Vaccine Adjuvant.

    Directory of Open Access Journals (Sweden)

    Grant E Frahm

    Full Text Available Microflow digital imaging (MDI has become a widely accepted method for assessing sub-visible particles in pharmaceutical formulations however, to date; no data have been presented on the utility of this methodology when formulations include opaque vaccine adjuvants. This study evaluates the ability of MDI to assess sub-visible particles under these conditions. A Fluid Imaging Technologies Inc. FlowCAM® instrument was used to assess a number of sub-visible particle types in solution with increasing concentrations of AddaVax™, a nanoscale squalene-based adjuvant. With the objective (10X used and the limitations of the sensor resolution, the instrument was incapable of distinguishing between sub-visible particles and AddaVax™ droplets at particle sizes less than 5 μm. The instrument was capable of imaging all particle types assessed (polystyrene beads, borosilicate glass, cellulose, polyethylene protein aggregate mimics, and lysozyme protein aggregates at sizes greater than 5 μm in concentrations of AddaVax™ up to 50% (vol:vol. Reduced edge gradients and a decrease in measured particle sizes were noted as adjuvant concentrations increased. No significant changes in particle counts were observed for polystyrene particle standards and lysozyme protein aggregates, however significant reductions in particle counts were observed for borosilicate (80% of original and cellulose (92% of original particles. This reduction in particle counts may be due to the opaque adjuvant masking translucent particles present in borosilicate and cellulose samples. Although the results suggest that the utility of MDI for assessing sub-visible particles in high concentrations of adjuvant may be highly dependent on particle morphology, we believe that further investigation of this methodology to assess sub-visible particles in challenging formulations is warranted.

  16. Marker-assisted breeding for introgression of opaque-2 allele into elite maize inbred line BML-7.

    Science.gov (United States)

    Krishna, M S R; Sokka Reddy, S; Satyanarayana, Sadam D V

    2017-07-01

    Improvement of quality protein maize (QPM) along with high content of lysine and tryptophan had foremost importance in maize breeding program. The efficient and easiest way of developing QPM hybrids was by backcross breeding in marker aided selection. Hence, the present investigation aimed at conversion of elite maize inbred line BML-7 into QPM line. CML-186 was identified to be a donor variety as it revealed high-quality polymorphism with BML-7 for opaque-2 gene specific marker umc1066. Non-QPM inbred line BML-7 was crossed with QPM donor CML-186 and produced F1 followed by the development of BC1F1 and BC2F1 population. Foreground selection was carried out with umc1066 in F1, and selected plants were used for BC1F1 and BC2F1 populations. Two hundred plants were screened in both BC1F1 and BC2F1 population with umc1066 for foreground selection amino acid modifiers. Foreground selected plants for both opaque-2 and amino acid modifiers were screened for background selection for BML-7 genome. Recurrent parent genome (RPG) was calculated for BC2F1 population plants. Two plants have shown with RPG 90-93% in two generation with back cross population. Two BC2F2 populations resulted from marker recognized BC2F1 individuals subjected toward foreground selection followed by tryptophan estimation. The tryptophan and lysine concentration was improved in all the plants. BC2F2 lines developed from hard endosperm kernels were selfed for BC2F2 lines and finest line was selected to illustrate the QPM version of BML-7, with 0.97% of tryptophan and 4.04% of lysine concentration in protein. Therefore, the QPM version of BML-7 line can be used for the development of single cross hybrid QPM maize version.

  17. Blinded comparison of faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation

    Energy Technology Data Exchange (ETDEWEB)

    Cowlam, S. [Sunderland Royal Hospital, Sunderland (United Kingdom); Vinayagam, R.; Khan, U.; Marsden, S.; Minty, I.; Moncur, P.; Bain, I. [University Hospital of North Durham, Durham (United Kingdom); Yiannakou, Y.J. [University Hospital of North Durham, Durham (United Kingdom)], E-mail: yan.yiannakou@cddft.nhs.uk

    2008-12-15

    Aim: To compare faecal loading on plain radiography versus radio-opaque marker transit studies in the assessment of constipation. Methods: The study group was a convenience sample of patients attending the Durham Constipation Clinic. All patients underwent transit studies according to an established protocol, and severity of constipation was assessed contemporaneously using a validated questionnaire (PAC-SYM). Transit studies were performed using radio-opaque markers that were ingested over 3 consecutive days, with a radiograph taken on the fourth day. Digital images of the radiograph were digitally altered to remove all traces of the transit markers without affecting the underlying pattern of faecal loading. Four observers assessed faecal loading independently; two clinicians (C1 and C2) and two radiologists (R1 and R2). C1 and R1 used a previously described formal scoring method of assessing faecal loading, whereas C2 and R2 assessed the images as if they were in a clinic or reporting session, grading the faecal loading as mild, moderate, or severe. Results: One hundred patients were recruited out of 186 presenting in a 2-year period. All patients completed assessments. The correlation between observers was only fair to moderate (r ranging from 0.34-0.51). There were some surprisingly marked disagreements in 10-18% of assessments. The correlation between faecal loading and transit was weak for all observers (r ranging from 0.261-0.311). Symptom severity did not correlate with faecal loading. Conclusion: These results suggest that there is considerable inter-observer variation in the radiological assessment of faecal loading, irrespective of the training or method used by the observer, and that there is very poor correlation with colonic transit. The diagnosis of constipation, and the assessment of severity, is best performed clinically.

  18. Synthesis of the refined calcium phosphate for bone china porcelain from oyster shell

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y.H. [Department of Environmental Engineering, Kumsung Environment College (Korea, Republic of); Chang, Pok-Ki; Lim, Yong-Mu [Department of Inorganic Materials Engineering, Chonnam National University, Kwangju (Korea, Republic of)

    1997-11-01

    In this study, the oyster shell was calcined at high temperature (>800 deg. C) in reducing atmosphere to remove impurities, refined by elutriation and magnetic separator and reacted with phosphate to synthesized di-calcium phosphate(DCP). Studies for characteristic and application to bone china porcelain of this synthesized DCP were done. By thermal and ICP analysis, the oyster shell was composed of the calcium carbonate(CaCO{sub 3}) with impurities less than 2 wt%. Fe{sub 2}O{sub 3}, TiO{sub 2} and MnO belonged to colouring material and its contents were 0.17, 0.04 and 0.02 wt%, respectively. To research reducing behavior of colouring materials Fe{sub 2}/O{sub 3} was calcined at various temperature in reducing atmosphere. Metal Fe content increased with increasing calcining temperature. After pass through magnetic separator, contents of colouring material were reduced Fe{sub 2}O{sub 3} to 0.07, TiO{sub 2} to 0.03 and MnO to 0.01 wt%, respectively. Di-calcium phosphate synthesized from calcium-hydroxide based upon oyster shell and phosphate in ph=3.5 showed crystalline phase of brushite type, and changed to {Upsilon}-Ca{sub 2}P{sub 2}O{sub 7} at 450 deg. C. For DCP calcined at 1200.deg. C, average particle size was 3.56{mu}m, specific surface area was 1.6851 m{sup 2}/g and had no agglomerate. For bone china used the synthesized DCP, the high temperature slump was 7.5 mm, the shrinkage was 13.7% and the whiteness was 95.26% similarly situated with that of H company. (author). 18 refs., 9 figs., 4 tabs.

  19. Effect of provisional restorations on the final bond strengths of porcelain laminate veneers.

    Science.gov (United States)

    Aykent, F; Usumez, A; Ozturk, A N; Yucel, M T

    2005-01-01

    The purpose of this in vitro study was to evaluate the effect of the different provisional restorations cementation techniques on the final bond strengths of porcelain laminate veneers (PLVs). Thirty-six extracted human central incisors were sectioned 2 mm below the cemento-enamel junction, and crown parts were embedded into self-cure acrylic resin. Standardized PLV preparations were carried out on labial surfaces of the teeth. Then the teeth were randomly divided into three groups of 12 each. In group 1, provisional restorations were cemented with eugenol-free cement. In group 2, prepared teeth surfaces were first coated with a desensitizing agent then provisional restorations were cemented with resin cement. In group 3, provisional restorations were not fabricated to serve as control. After specimens were stored in distilled water for 2 weeks, provisional restorations were removed and final IPS Empress 2 ceramic veneers were bonded with a dual-curing resin. Two microtensile samples from each tooth measuring 1.2 x 1.2 x 5 mm were prepared. These sections were subjected to microtensile testing and failure values were recorded. The data were analysed by one-way anova and Tukey HSD tests. The PLVs, placed on the tooth surface that had received a dentine desensitizer and provisional restorations luted with resin cement (group 2), showed the lowest bond strength in all test groups. But no statistically significant differences were found between the bond strength of PLVs in control group (no provisional restorations) and group 1 (provisional restorations cemented with eugenol-free cement before final cementations). Scanning electron microscopic (SEM) examination of this study also showed that the bonding to enamel surface was better in control group and group 1 than group 2.

  20. Evaluation of performance of modified sodium lignosulfonate additives as reinforcing agent in porcelain stoneware tiles

    Directory of Open Access Journals (Sweden)

    Rastelli, E.

    2010-10-01

    Full Text Available A sodium salt of a modified lignosulfonate at different percentages was added to a porcelain stoneware suspension and the effects on the rheological properties of slips and on the mechanical properties of prepared samples were investigated. As the presence of sulfonates groups can change the stability of dispersion, a rheological characterisation was necessary to find the critical concentration to obtain well dispersed suspensions and high MOR values. The suspensions stability was tested by oscillatory measurements and the increase of elastic modulus in the suspension corresponded to a MOR and to Young’s modulus increase as well. Finally, to explain the results obtained by the mechanical characterisation of the prepared samples, a model drawing on the composite materials experience, is suggested.

    Usando distintos porcentajes, se añadió sal de sodio de un lignosulfonato modificado, a una suspensión de gres porcelánico, y se investigaron los efectos sobre las propiedades reológicas de las suspensiones y sobre las propiedades mecánicas de las muestras preparadas. Debido a que la presencia de grupos de sulfonatos puede modificar la estabilidad de la dispersión, fue necesario realizar una caracterización reológica para averiguar la concentración crítica necesaria para la obtención de suspensiones bien dispersas y altos valores de MOR. Se analizó la estabilidad de las suspensiones por medio de mediciones oscilatorias y el incremento del módulo elástico en la suspensión que corresponde al incremento de un módulo MOR y de un módulo de Young también. Finalmente, para explicar los resultados obtenidos por medio de la caracterización mecánica de las muestras preparadas, se sugiere un modelo que parte de la experiencia con los materiales compuestos.

  1. Impact of brewing process operations on phytate, phenolic compounds and in vitro solubility of iron and zinc in opaque sorghum beer

    NARCIS (Netherlands)

    Kayodé, A.P.P.; Hounhouigan, J.D.; Nout, M.J.R.

    2007-01-01

    Opaque sorghum beer is a significant component of the diet of millions of poor people in rural Africa. This study reports the effect of traditional brewing operations on its level of micronutrients, especially iron and zinc. The example of a West African sorghum beer, tchoukoutou, in Northern Benin

  2. Impact of brewing process operations on phytate, phenolic compounds and in vitro solubility of iron and zinc in opaque sorghum beer

    NARCIS (Netherlands)

    Kayodé, A.P.P.; Hounhouigan, J.D.; Nout, M.J.R.

    2007-01-01

    Opaque sorghum beer is a significant component of the diet of millions of poor people in rural Africa. This study reports the effect of traditional brewing operations on its level of micronutrients, especially iron and zinc. The example of a West African sorghum beer, tchoukoutou, in Northern Benin

  3. Survey on energetic processes of drying and firing of porcelain; Levantamento energetico em processos de secagem e queima de porcelanas

    Energy Technology Data Exchange (ETDEWEB)

    Ferraz, Andre D.; Machado Junior, Antonio R.; Rocha, Ivan C.C. da; Azevedo, Jorge G.W. de; Konishi, Ricardo; Lehmkuhl, Willian A. [Companhia de Gas de Santa Catarina (SCGAS), Florianopolis, SC (Brazil); Nunes, Andrea T.; Possamai, Talita S.; Nicolau, Vicente de P. [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil)

    2012-07-01

    This study evaluates the processes of drying and firing of porcelain products. Ambient air heated to an average temperature of 100 deg C is used for drying the pieces. The air heating is done by heat exchangers located within the saturated steam dryers. A main steam's line coming from a boiler fuel feeds all the equipment, while the condensate returned to a reservoir for reheating. The yield obtained from the boiler is about 80%, a reasonable value for this type of equipment. The consumption of this equipment represents 27.6% of the energy used in the stage of burning. However, according to measurements taken about 30% of the energy available in the network is lost in the steam vapor transport and condensation. Considering the potential generation of heat from the fuel, including the boiler efficiency, estimated at about 40% lost energy in the generation and distribution of steam. In accordance with the evaluation, a competitive option would be the direct combustion of natural gas in each dryer, adopting a better control and combustion system, since the products of combustion may impact the quality of the porcelain. A new configuration is proposed as a conclusion. (author)

  4. Use of industrial wastes as opacifiers in porcelain tile bodies; Utilizacion de Residuos industriales como opacificantes en pastas de gres porcelanico

    Energy Technology Data Exchange (ETDEWEB)

    Mestre, S.; Palacios, M. D.; Soriano, M.; Sanchez, E.; Rodriguez, L.; Nunez, J. F.; Rivera, P.

    2010-07-01

    The present research was conducted to assess the feasibility of using two kinds of industrial wastes as opacifiers in porcelain tile bodies, as well as to define what pre-treatment would be required to prepare the wastes for such use. The characteristics of the wastes were analysed, first, to determine their chemical and mineralogical composition, as well as their behaviour when subjected to heat, in order to identify any undesirable substances and to establish suitable conditions for removing these with simple methods. This allowed suitable materials to be obtained for use in porcelain tile compositions. The effects were then studied of the incorporation of these pre-treated waste materials on porcelain tile characteristics. The results obtained indicate that the two waste materials used in this research have a significant opacifying capability, which makes them of great interest as possible raw materials for products that are not required to have maximum whiteness values. The only drawback detected in one of these wastes was that the porcelain tile composition needed to be slightly adjusted in order to ensure that its behaviour during firing did not change. (Author) 6 refs.

  5. 75 FR 62144 - Porcelain-on-Steel Cooking Ware From China and Taiwan; Top-of-the-Stove Stainless Steel Cooking...

    Science.gov (United States)

    2010-10-07

    ..., Deputy Agency Ethics Official, at 202-205-3088. Limited disclosure of business proprietary information... countervailing duties). If you are a trade/business association, provide the information, on an aggregate basis...: Institution of five-year reviews concerning the antidumping duty orders on porcelain-on-steel cooking ware...

  6. Analysis on the Green Colour of Jingdezhen Greenish white porcelain of Song Dynasty%论宋代景德镇青白瓷之青

    Institute of Scientific and Technical Information of China (English)

    姜丽; 陆宝荣; 张晓东

    2012-01-01

    在中国的陶瓷历史中,宋代陶瓷最具有代表性、最具审美价值。尤其是宋代景德镇青白瓷以它那质朴、典雅的艺术风格以及崇尚自然美的文化精神,受到人们的推崇。探析青之色彩让青白瓷体现出美学特征,发现隐藏在色彩背后的美学因素,宋代青白瓷色彩所呈现的美学特征是多种因素的结果。%Most of the ceramic history and the most representative of the Song dynasty porcelain aesthetic value considered ceramic history of the golden age In China. Jingdezhen porcelain populared by the people for his elegant artistic style and advocating natural culture spirit, This is in the green colour lets paper attempts to embody aesthetic features blue porcelain also found hidden in the aesthetic factors behind the color. We will find that song green colour porcelain of aesthetic characteristics is not accidental or may unilateral!y caused many factors, it is undoubtedly the results.

  7. Illustration of compositional variations over time of Chinese porcelain glazes combining micro-X-ray Fluorescence spectrometry, multivariate data analysis and Seger formulas

    Science.gov (United States)

    Van Pevenage, J.; Verhaeven, E.; Vekemans, B.; Lauwers, D.; Herremans, D.; De Clercq, W.; Vincze, L.; Moens, L.; Vandenabeele, P.

    2015-01-01

    In this research, the transparent glaze layers of Chinese porcelain samples were investigated. Depending on the production period, these samples can be divided into two groups: the samples of group A dating from the Kangxi period (1661-1722), and the samples of group B produced under emperor Qianlong (1735-1795). Due to the specific sample preparation method and the small spot size of the X-ray beam, investigation of the transparent glaze layers is enabled. Despite the many existing research papers about glaze investigations of ceramics and/or porcelain ware, this research reveals new insights into the glaze composition and structure of Chinese porcelain samples. In this paper it is demonstrated, using micro-X-ray Fluorescence (μ-XRF) spectrometry, multivariate data analysis and statistical analysis (Hotelling's T-Square test) that the transparent glaze layers of the samples of groups A and B are significantly different (95% confidence level). Calculation of the Seger formulas, enabled classification of the glazes. Combining all the information, the difference in composition of the Chinese porcelain glazes of the Kangxi period and the Qianlong period can be demonstrated.

  8. Five-year clinical evaluation of 300 teeth restored with porcelain laminate veneers using total-etch and a modified self-etch adhesive system.

    Science.gov (United States)

    Aykor, Arzu; Ozel, Emre

    2009-01-01

    This study evaluated the long-term clinical performance of porcelain laminate veneers luted with hybrid composite in combination with total-etch and self-etch adhesive systems. The study was performed on 30 patients ranging in age between 28 and 54 years. Ten veneers were performed per patient in the maxillary arch. In Group 1, 150 teeth were treated with porcelain veneers, using a total-etch adhesive system (Scotchbond Multi-Purpose Plus, 3M ESPE). In Group 2, 150 teeth were bonded with a self-etch adhesive system (AdheSE, Ivoclar-Vivadent). All the veneers were luted with a light-cured hybrid composite (Z100, 3M ESPE). The patients were recalled after 1, 2 and 5 years. Modified United States Public Health Service (USPHS) criteria were utilized to evaluate the porcelain laminate veneers in terms of marginal adaptation, cavo-surface marginal discoloration, secondary caries, postoperative sensitivity, satisfaction with restoration shade and gingival tissue response. Data were analyzed using the Chi-Square test (p 0.05). Porcelain veneers exhibited successful clinical performance with both total-etch and two-step self-etch adhesives at the end of five-years.

  9. ON THE ROLE OF ZITHERN PLAYS IN THE DEVELOPMENT OF PORCELAIN MUSIC%筝乐在瓷乐发展中的作用

    Institute of Scientific and Technical Information of China (English)

    邹婷媛; 段友芳; 徐玉莲

    2011-01-01

    中国的民族音乐乐器,有着悠久的历史。瓷乐器也是一种古老的民间乐器,经过不断地发展创新与实践,已形成为多种瓷乐器组合,其音色特殊而鲜明,听者通常会有新鲜的感觉。随着瓷乐的发展,如今的瓷乐融合了中国传统的乐器形式和特色。筝乐器因为中华民族特有的历史与文化,经久不衰深受大众喜爱。筝乐与瓷乐二者的结合带给音乐一种全新的生命力和内涵,并对民族传统艺术的发展与进步作出了一定的贡献。本文旨在于阐述中国传统乐器的相关知识,结合瓷乐与筝乐的特点与关系,通过分析二者的发展过程来探讨筝乐在瓷乐发展中的融合与运用方式。%China national musical instruments,has a long history.Musical porcelain is a kind of ancient folk instruments,through continuous development and innovation and practice,has formed a variety of porcelain combination of instruments,the special and distinctive timbre,the listener will typically feel fresh.With the development of porcelain music,now the porcelain music combines traditional Chinese musical forms and characteristics.Zheng instrument because of Chinese history and culture,enduring popular.Music and porcelain music with the combination of the two to give music a new vitality and connotation,and the traditional ethnic art development and progress to make a certain contribution.This paper aims to elaborate the relevant knowledge of traditional Chinese musical instruments,in combination with porcelain music and music features and relations,through the analysis of the two development process to discuss music in porcelain music development in the fusion and application modes.

  10. The influence of four different cements and two A2 and A3.5 shade veneering porcelain on the final color of cercon high translucent restoration

    Directory of Open Access Journals (Sweden)

    Niloofar Mojarad

    2016-12-01

    Full Text Available Statement of Problem: to evaluate the effect of four different cements on the final color of cerconht restoration with veneering porcelain thickness of two different shade, A2 and A3.5. Method: A combination of cylindrical was made of four cements in thickness of 1.1 mm, four cerconht ceramic in thickness of 1.3 mm and 12 veneering porcelain in two different thickness of 1.3 mm and 1 mm and two shades A2 and A3.5. Overlapping the discs on a gray background enable ΔE calculations of each combination in comparing with Vitapan classic shade guide with using CIE L*a*b* method. Two-way ANOVA and Tukey tests were used for data analysis. Results:The collected data showed statistically significant difference for amounts of L*, a*, b* and ΔE on shade A2 in different veneering porcelain thickness (p<0.05. There were significant difference only in amount of L* and ΔE on shade A3.5 in veneering porcelain (p<0.05. In comparison between different cements, there was significant difference only for a* (p<0.05, and there were no significant difference for L*, b*, ΔE. Significance:It was concluded that the thickness of veneering porcelain is more important factor than type of cement in color matching of cerconht restoration.Therefore, it is suggested, the thickness of anterior teeth preparation should be at least 105 mm for color matching.

  11. Comparison of the Effects of Three Preparation Designs: Shoulder, Chamfer and Deep Chamfer in the Palatal Surface on Resistance against Breakage of Porcelain Laminate Veneer

    Directory of Open Access Journals (Sweden)

    Jallalian E.

    2011-02-01

    Full Text Available Statement of Problem: Porcelain laminate veneer is one of the most important restorations in dentistry because of stable esthetic and low destructive technique. But the main reason of failure in this treatment is porcelain fracture. Therefore, tooth preparation has an important role in fracture resistance of porcelain laminate veneer. Purpose: The aim of this in-vitro study was to compare the effect of tree preparation designs, shoulder and chamfer and heavy chamfer, on fracture strength of porcelain laminate veneer. Materials and Method: This experimental and in-vitro study was performed on 30 upper central teeth without fracture, carries or any problem. The teeth were divided into three-10 teeth groups. Then, the preparation design was performed perfectly. In the palatal surfaces of the first group we used deep chamfer preparation design and the shoulder and the chamfer designs were performed for the second and third groups, respectively. Then the samples were put in instron machine with the angle of 30 degrees. The force rate which led to break in those samples was determined. The data were analysed usig t-test.Result: Resistance against breakage in the deep chamfer, shoulder and chamfer groups were 283.40 ± 17, 231.50 ± 25.61 and 254 ± 21.71 Newton, repectvely. No significant difference was found among the groups .Conclusion: The higher fracture resistance was observed in deep Chamfer/palatal over lap technique, so we prefer to use this kind of preparation for palatal extension of Porcelain Laminate Veneers.

  12. Effect of selective laser melting deposition cobalt chromium alloy porcelain crown restoration on related molecule contents in serum and gingival crevicular fluid

    Institute of Scientific and Technical Information of China (English)

    Yu-Hua Wei; Lei Yang

    2015-01-01

    Objective:To study the effect of selective laser melting deposition cobalt chromium alloy porcelain crown restoration on contents of inflammatory cytokines and adhesion molecules in serum and gingival tissue.Methods:80 cases of patients who received cobalt chromium alloy porcelain crown restoration in our hospital from May 2013 to August 2014 were enrolled and randomly divided into two groups. Observation group received selective laser melting deposition cobalt chromium alloy porcelain crown restoration and control group received casting cobalt chromium metal porcelain crown restoration. Then contents of inflammatory cytokines and adhesion molecules in serum and gingival crevicular fluid of both groups were detected.Results: (1) Inflammatory cytokines: compared with serum inflammatory cytokine contents of control group, serum NF-κB, IL-6, IL-8, IL-1β, TNF-α and NO contents of observation group trended to decrease; (2) Adhesion molecules in gingival crevicular fluid: compared with adhesion molecule contents in gingival crevicular fluid of control group, mRNA contents of CD11a, CD18, LFA-1, E-selectin and P-selectin in gingival crevicular fluid of observation group trended to decrease; (3) Adhesion molecules in serum: compared with adhesion molecule contents in serum of control group, sICAM-1 and sVCAM-1 contents in serum of observation group were lower.Conclusion: Selective laser melting deposition cobalt chromium alloy porcelain crown restoration is helpful to relieve inflammatory response of gingival tissue, with expression of decreased generation of inflammatory cytokines and adhesion molecules; it’s an ideal material for crown restoration.

  13. Static opaque chamber-based technique for determination of net exchange of CO2 between terrestrial ecosystem and atmosphere

    Institute of Scientific and Technical Information of China (English)

    ZOU Jianwen; HUANG Yao; ZHENG Xunhua; WANG Yuesi; CHEN Yuquan

    2004-01-01

    Terrestrial carbon cycling is one of the hotspots in global change issues. In this paper, we presented the rationale for determination of net exchange of CO2 between terrestrial and the atmosphere (NEE) and the methods for measuring several relevant components. Three key processes for determination of NEE were addressed, including the separation of shoot autotrophic respiration from total CO2 emissions of the ecosystem, the partition of root respiration from soil CO2 efflux, and the quantification of rhizodeposition C from NPP. With an understanding of the processes involved in the CO2 exchange between terrestrial and the atmosphere, we estimated NEE of rice ecosystem in Nanjing based on field measurements of CO2 emissions and several relevant biotic components as well as abiotic factors. The field measurements of CO2 emissions were made over the rice-growing seasons in 2001 and 2002 with the static opaque chamber method. Calculations indicated that the seasonal pattern of NEE is comparable for two seasons. Either net carbon emission or fractional carbon fixation occurred during 3 weeks after rice transplanting and thereafter net carbon fixation appeared with an increasing trend as rice growing. Higher net carbon fixation occurred in the rice developmental period from elongating to heading. A decline trend in the fixation was documented after rice heading. The mean daily NEE was -6.06 gC·m-2 in 2001 season and -7.95 gC·m-2 in 2002 season, respectively. These values were comparable to the results obtained by Campbell et al. Who made field measurements with the Bowen ratio-energy balance technique in irrigated rice, Texas USA. Moreover, the mean daily NEE in this study was also comparable to the values obtained from a Japanese rice paddy with the eddy covariance method under the similar water regime, either drainage course or waterlogged. It is concluded that NEE determined by the static opaque chamber method is comparable and in agreement with those measured by

  14. Do reading processes differ in transparent versus opaque orthographies? A study of acquired dyslexia in Welsh/English bilinguals.

    Science.gov (United States)

    Tainturier, Marie-Josèphe; Roberts, Jennifer; Leek, E Charles

    2011-12-01

    In English, the relationship between the written and spoken forms of words is relatively opaque, leading to proposals that skilled reading requires two procedures: (a) a sublexical grapheme/phoneme conversion process allowing the correct reading of regular words (CAT) and new or pseudowords (ZAT); (b) a lexical process necessary to read irregular words accurately (TWO) and assumed to be the dominant process for familiar words. However, it has been argued that the sublexical process may be sufficient in highly transparent languages such as Welsh. If this is the case, damage to the sublexical process may lead to more severe deficits in transparent languages due to the lack of an alternative lexical process. To test this hypothesis, we compared Welsh and English oral reading and written-word recognition and comprehension in seven bilingual stroke participants with comparably impaired pseudoword reading in English and Welsh. Performance was remarkably similar across languages. Irrespective of the language tested, words were read more accurately than pseudowords. Lexical decision and word comprehension were as accurate in Welsh and in English, and when imageability effects were present they were of a similar size in both languages. This study does not support the hypothesis that orthographic transparency determines the nature of cognitive reading processes, but rather suggests that readers develop a sight vocabulary through reading experience irrespective of orthographic transparency.

  15. Rehabilitation of a patient with amelogenesis imperfecta using porcelain veneers and CAD/CAM polymer restorations: A clinical report.

    Science.gov (United States)

    Saeidi Pour, Reza; Edelhoff, Daniel; Prandtner, Otto; Liebermann, Anja

    2015-01-01

    The complete dental rehabilitation of patients with a vertical dimension loss (VDL) caused by structural enamel deficits associated with amelogenesis imperfecta (AI) represents a difficult challenge for restorative teams. Accurate analysis and treatment planning that includes esthetic and functional evaluations and adequate material selection are important prerequisites for successful results. Long-term provisional restorations play an important role in exploring and elucidating the patients' esthetic demands and functional needs. Restorative treatment options can vary from requiring only oral hygiene instructions to extensive dental restorations that include composite fillings, ceramic veneers, metal-ceramic, or all-ceramic crowns. This case report describes a full-mouth rehabilitation of a patient with amelogenesis imperfecta including the case planning, bite replacement, preparation, and restoration setting steps with an experimental CAD/CAM polymer and porcelain veneers.

  16. An in vitro study to evaluate the difference in shade between commercially available shade guides and glazed porcelain

    Directory of Open Access Journals (Sweden)

    P Manimaran

    2016-01-01

    Full Text Available Introduction: Smile is one of the most important interactive communication skills of a person. A smile is the key factor for an aesthetic appearance. Hence aesthetics is one of the motivating factor for the patients to seek dental care. Correction of unaesthetic appearance gives a positive effect to the self esteem of the patient. Aim: The aim of this study was to compare the difference in the shade between the commercially available shade guides namely Vita Classical And Ivoclar Chromascop and the fired porcelain samples fabricated using Vita Zahnfabrik VMK 95 and Ivoclar Classic Materials respectively. Objectives: The objective of this study was to obtain a matching brand of material that has a particular shade tab among the brands used. Conclusion: To conclude, Ivoclar material matched the chromascop shade guide better than the vita material matched the vita classic shade guide.

  17. 粉彩瓷艺术风格刍议%ON THE STYLE OF FAMILLE ROSE PORCELAIN

    Institute of Scientific and Technical Information of China (English)

    吴艳青

    2012-01-01

    Famille rose porcelain is popular in the Qing Dynasty and contemporary,the style has diversity,age and unique features,the development and evolvement of the style of each period performance varied,contemporary pastel art style diversity,in the traditional basis of innovation.%粉彩瓷流行于清代直至当代,其在风格表现上具有多样性、时代性和独特性特征,其发展演变各时期的风格表现各不相同,当代粉彩艺术风格表现手法多样,在传统基础上进行创新。

  18. Defective dental restorations: to repair or not to repair? Part 2: All-ceramics and porcelain fused to metal systems.

    Science.gov (United States)

    Blum, Igor R; Jagger, Daryll C; Wilson, Nairn H F

    2011-04-01

    With the increasing use of ceramics in restorative dentistry, and trends to extend restoration longevity through the use of minimal interventive techniques, dental practitioners should be familiar with the factors that may influence the decision either to repair or replace fractured metal-ceramic and all-ceramic restorations and, also, the materials and techniques available to repair these restorations. This second of two papers addresses the possible modes of failure of ceramic restorations and outlines indications and techniques in this developing aspect of restoration repair in clinical practice. The repair of metal-ceramic and all-ceramic restorations is a reliable low-cost, low-risk technique that may be of value for the management of loss or fracture of porcelain from a crown or bridge in clinical practice.

  19. 商周时期原始瓷的中子活化分析及相关问题讨论%INAA of Shang-Zhou Period Proto-porcelain and a Discussion of Related Problems

    Institute of Scientific and Technical Information of China (English)

    陈铁梅; Rapp G.Jr.; 荆志淳

    2003-01-01

    Previously the authors studied proto-porcelain samples from early and middle Shang sites (Wucheng, Zhengzhou, Jingnansi, Panlongcheng and Tonggushan) by means of instrumental neutron activation analysis (INAA) . The results showed them to have a similar chemical composition pattern, which suggested that these proto-porcelain shards might have been produced in the same area around Wucheng. In the present paper, the authors report their new analysis on proto-porcelain shards from sites of middle Shang to early Zhou times (Xiaoshuangqiao, Anyang Yinxu, Zhouyuan, Liulihe and Zhangjiapo). For the samples later than the middle Yinxu period, new composition patterns are detected, which indicates diversity in their provenance. The significantly lower Fe2O3 and lower Tio2 contents of these later samples demonstrate the advance of then proto-porcelain industry. Two samples from Zhouyuan with Al2O3 contents higher than 25% seem to suggest that in addition to porcelain stone other materials might also have been used in proto-porcelain production in the Western Zhou period.

  20. Applied superconductivity

    CERN Document Server

    Newhouse, Vernon L

    1975-01-01

    Applied Superconductivity, Volume II, is part of a two-volume series on applied superconductivity. The first volume dealt with electronic applications and radiation detection, and contains a chapter on liquid helium refrigeration. The present volume discusses magnets, electromechanical applications, accelerators, and microwave and rf devices. The book opens with a chapter on high-field superconducting magnets, covering applications and magnet design. Subsequent chapters discuss superconductive machinery such as superconductive bearings and motors; rf superconducting devices; and future prospec

  1. Crystal structure of the WOPR-DNA complex and implications for Wor1 function in white-opaque switching of Candida albicans.

    Science.gov (United States)

    Zhang, Shicheng; Zhang, Tianlong; Yan, Minghui; Ding, Jianping; Chen, Jiangye

    2014-09-01

    Wor1 (white-opaque switching regulator 1) is a master regulator of the white-opaque switching in Candida albicans, an opportunistic human fungal pathogen, and is associated with its pathogenicity and commensality. Wor1 contains a conserved DNA-binding region at the N-terminus, consisting of two conserved segments (WOPRa and WOPRb) connected by a non-conserved linker that can bind to specific DNA sequences of the promoter regions and then regulates the transcription. Here, we report the crystal structure of the C. albicans Wor1 WOPR segments in complex with a double-stranded DNA corresponding to one promoter region of WOR1. The sequentially separated WOPRa and WOPRb are structurally interwound together to form a compact globular domain that we term the WOPR domain. The WOPR domain represents a new conserved fungal-specific DNA-binding domain which uses primarily a conserved loop to recognize and interact specifically with a conserved 6-bp motif of the DNA in both minor and major grooves. The protein-DNA interactions are essential for WOR1 transcriptional regulation and white-to-opaque switching. The structural and biological data together reveal the molecular basis for the recognition and binding specificity of the WOPR domain with its specific DNA sequences and the function of Wor1 in the activation of transcription.

  2. Applied mathematics

    CERN Document Server

    Logan, J David

    2013-01-01

    Praise for the Third Edition"Future mathematicians, scientists, and engineers should find the book to be an excellent introductory text for coursework or self-study as well as worth its shelf space for reference." -MAA Reviews Applied Mathematics, Fourth Edition is a thoroughly updated and revised edition on the applications of modeling and analyzing natural, social, and technological processes. The book covers a wide range of key topics in mathematical methods and modeling and highlights the connections between mathematics and the applied and nat

  3. The study of chemical composition and elemental mappings of colored over-glaze porcelain fired in Qing Dynasty by micro-X-ray fluorescence

    Science.gov (United States)

    Lin, Cheng; Meitian, Li; Youshi, Kim; Changsheng, Fan; Shanghai, Wang; Qiuli, Pan; Zhiguo, Liu; Rongwu, Li

    2011-02-01

    It is very difficult to measure the chemical composition of colored pigments of over-glaze porcelain by X-ray fluorescence because it contains high concentration of Pb. One of the disadvantages of our polycapillary optics is that it has low transmission efficiency to the high energy X-ray. However, it is beneficial to measure the chemical compositions of rich Pb sample. In this paper, we reported the performances of a tabletop setup of micro-X-ray fluorescence system base on slightly focusing polycapillary and its applications for analysis of rich Pb sample. A piece of Chinese ancient over-glaze porcelain was analyzed by micro-X-ray fluorescence. The experimental results showed that the Cu, Fe and Mn are the major color elements. The possibilities of the process of decorative technology were discussed in this paper, also.

  4. Applied Enzymology.

    Science.gov (United States)

    Manoharan, Asha; Dreisbach, Joseph H.

    1988-01-01

    Describes some examples of chemical and industrial applications of enzymes. Includes a background, a discussion of structure and reactivity, enzymes as therapeutic agents, enzyme replacement, enzymes used in diagnosis, industrial applications of enzymes, and immobilizing enzymes. Concludes that applied enzymology is an important factor in…

  5. An investigation into the role of core porcelain thickness and lamination in determining the flexural strength of In-Ceram dental materials.

    Science.gov (United States)

    Alshehri, Sharifa Abdullah

    2011-06-01

    A biaxial flexure test was conducted to evaluate the effect of reducing the thickness of In-Ceram core material and veneering with Vitadur α dentine porcelain on its flexural strength. Four groups of 10 discs were tested; group I discs were In-Ceram discs with mean thickness of 1.58 ± 0.08 mm, group II discs were In-Ceram discs with mean thickness of 1.0 ± 0.11 mm, group III discs were laminated In-Ceram core porcelain/Vitadur α discs with a mean total thickness of 2.06 ± 0.15 mm and core porcelain thickness of 1.0 ± 0.11 mm; group IV discs were Vitadur α discs with a mean thickness of 2.08 ± 0.16 mm. Mean flexural strength values decreased between groups: 436 ± 38 MPa for group I, 352 ± 30 MPa for group II, 237 ± 24 MPa for group III, and 77 ± 14 MPa for group IV. The result of ANOVA and Tukey tests indicated that the mean flexural strength of group II was significantly less than group I, indicating that thickness of the In-Ceram core provides critical flexural strength to the final product. The addition of ≈ 1 mm of Vitadur α veneering porcelain to In-Ceram core significantly (p= 0.05) reduced the flexural strength as compared to the nonveneered In-Ceram core specimens (group II). The Vitadur α specimens (group IV) were significantly weaker than all the other groups. This study indicates that lamination should be avoided in areas where maximum strength is required for In-Ceram all-ceramic crowns and bridges. © 2011 by the American College of Prosthodontists.

  6. Fiber-reinforced framework in conjunction with porcelain veneers for the esthetic replacement of a congenitally missing maxillary lateral incisor: a case study.

    Science.gov (United States)

    Benito, P P; Trushkowsky, R D; Magid, K S; David, S B

    2012-01-01

    This article presents a case of a congenitally missing right maxillary lateral incisor and the contralateral incisor with discolored composite resin restorations. The technique of fiber reinforcement in conjunction with porcelain veneers was used to provide a satisfactory outcome for the patient. The key learning points of the article are the following: proper diagnosis, treatment plan and appropriate utilization of materials are mandatory for a successful result.

  7. Opaque intraocular lens implantation

    OpenAIRE

    Yusuf IH; Patel CK

    2013-01-01

    Imran H Yusuf, CK Patel The Oxford Eye Hospital, West Wing, John Radcliffe Hospital, Headley Way, Headington, Oxford, United KingdomWe read with great interest the recent article by Lee et al,1 who described their clinical experience with three patients who underwent primary implantation of Morcher (Stuttgart, Germany) occlusive intraocular lenses (IOLs) across a variety of neuro-ophthalmic indications. We hope to offer some further insight into these clinical observations in the context of o...

  8. Secret Societies, Opaque Routes

    DEFF Research Database (Denmark)

    Garsten, Christina; Sörbom, Adrienne

    This paper departs from an interest in the involvement of business leaders in the sphere of politics, in the broad sense. At a general level, we are seeing a proliferation of usages of non-market corporate strategies, such as testimony, lobbying, interlocking of positions and other means to influ......This paper departs from an interest in the involvement of business leaders in the sphere of politics, in the broad sense. At a general level, we are seeing a proliferation of usages of non-market corporate strategies, such as testimony, lobbying, interlocking of positions and other means...... networks of business relations, the WEF is also able to amplify its own voice. The organized network, in the format of partial organization, which is the preferred form of organization of the WEF, comes with weakened power in the form of oversight and sanctions for the member corporations, but may allow...

  9. Scanning Electron Microscope Comparative Evaluation of Feldspathic Porcelain Surfaces under Irradiation by Different Powers of Neodymium-Doped Yttrium Aluminium Garnet (Nd:YAG) Laser

    Science.gov (United States)

    Hosseini, Mohammad Hashem; Sobouti, Farhad; Etemadi, Ardavan; Chiniforush, Nasim; Ayoub Bouraima, Stephane

    2013-01-01

    Introduction: Recent use of lasers for porcelain surface treatment for adhesion of brackets to restorations has not only showed some promising results, but is also accompanied with less undesirable effects among other advantages. The purpose of this study is the comparative electron microscope evaluation of feldspathic porcelain surfaces under irradiation by Neodymium-Doped Yttrium Aluminium Garnet (Nd:YAG) with different powers (0.75, 1.5 and 2W) via the acid etching with hydrofluoric acid (HF) technique. Methods: The glazed porcelain samples were obtained by duplicating labial surfaces of maxillary central incisor teeth. The specimens were randomly treated by 4 different methods. Group1 was etched with hydrofluoric acid 9.6%. Samples in group 2 to 4 were also irradiated by Nd:YAG laser with different powers: 0.75, 1.5 and 2W. Then the samples were prepared for evaluation by scanning electron microscope (SEM). Results: Etching quality from a porosity point of view was similar for group2 and HF group. Laser with power of 0.75W has little potential to create mechanical porosity. Conclusion: In regard of the results of this study, it is possible to benefit from Nd:YAG laser with appropriate parameters for surface conditioning. PMID:25606311

  10. The Ability of Dental Specialists to Distinguish Lateral Incisor Metal-Free From Porcelain-Fused-to-Metal Implant Supported Crowns.

    Science.gov (United States)

    De Melo, Eduardo V; Kauling, Ana Elisa C; Freitas, Sérgio Fernando T; Cardoso, Antônio C; Ferreira, Cimara Fortes

    2014-12-01

    The objective of this study was to evaluate the ability of dental specialists to distinguish lateral incisor metal-free from porcelain-fused-to-metal implant supported crowns in the anterior region. Five single-tooth implants in the maxillary lateral incisor region were restored with two types of implant-supported crowns (porcelain-fused-to-metal and metal-free). Photographs were presented to 20 evaluators. The evaluators had to answer whether the crown was: metal-free, porcelain-fused-to-metal or they could not tell the difference. The results showed that groups 1 (all participants), 3 (Restorative & Prosthodontic specialists), 4 (graduated 10 years) and 5 (graduated > 10 years) failed to respond correctly (P > 0.05) to which type of crown was presented to them. Group 2 (Periodontology & Implantology specialists) showed an accuracy rate of 35.6% (P = 0.009), in relation to metal-free crowns, 5.6 which is below the random index. The authors concluded that the evaluators from the 5 groups studied were unable to significantly distinguish which type of crown was used in the 10 presented situations.

  11. Conductive subtract development without corrosion for photovoltaic applications on porcelain stoneware according to free electrodes process; Desarrollo de sustratos conductores sin corrosion para aplicaciones fotovoltaicas sobre gres porcelanico mediante el proceso libre de electrodos

    Energy Technology Data Exchange (ETDEWEB)

    Reyes-Tolosa, M. D.; Al Aajmi, M.; Orozco-Messana, J.; Donderis, V.; Pascual, M.; Hernandez-Fenollosa, M. A.

    2010-07-01

    In the incipient world of functional industrial ceramics with photovoltaic applications, there is a need to reduce production costs while maximizing the systems useful life. The thin contact layers currently being manufactured are based on vacuum systems with high production costs and major problems of accelerated corrosion in photovoltaic applications. The electroless process produces very even and compact layers with very low costs through chelate-based chemicals. These layers have been formulated in this study with a view to obtaining appropriate electric characteristics for an optimum photoelectric performance in the assemblies. The morphological requirements are previously fitted through a glaze that acts as a barrier layer between the deposited coating and the porcelain tile, applied through tape casting. The characterisation of the metal layers obtained is started by SEM, an AFM and the Hall effect in order to determine the morphology and chemical characteristics required for these contact layers. The electric characterisation also allows their capacity for offering an optimum performance in the assemblies to be assessed. Finally, the performance of these layers with respect to corrosion is assessed in order to complete the assessment of their industrial suitability. (Author) 13 refs.

  12. Influence of the barite tenors of the Jaicos, Piaui, Brazil, clays on the ceramic properties of electric insulator porcelains; Influencia dos teores de barita das argilas de Jaicos, Piaui, Brasil nas propriedades ceramicas de porcelana de isoladores eletricos

    Energy Technology Data Exchange (ETDEWEB)

    Correa, W.L.P. [Escola SENAI Mario Amato, Sao Bernardo do Campo, SP (Brazil); Lima, M.B. [Faculdade Sao Bernardo, SP (Brazil); Carvalho, F.M.S. [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Geociencias

    2009-07-01

    The clays of the Municipality of Jaicos, Piaui, has been used as raw materials for the manufacture of insulators for company located in the municipality of Pedreira - Sao Paulo. It can be noticed in the clay blocks and consolidated, 'lenses' of barite. The mineralogical composition of clay and the nature of these 'lenses' were studied by chemical analysis, X-ray diffraction for mineralogical characterization. The clays are composed primarily by kaolinite, quartz, and some amount of illite and orthoclase. The presence of orthoclase does believe in a recent deposition of these clays. The 'lenses' were characterized as barite, BaSO{sub 4}. To check the influence of barite in the composition of bodies of porcelain to insulators made up six compositions with different levels of barite, obtained their own clay. It applies, then the tests of ceramic fracture to bending, water absorption, apparent porosity to determine the effect of the introduction of barite in the compositions. (author)

  13. Applied dynamics

    CERN Document Server

    Schiehlen, Werner

    2014-01-01

    Applied Dynamics is an important branch of engineering mechanics widely applied to mechanical and automotive engineering, aerospace and biomechanics as well as control engineering and mechatronics. The computational methods presented are based on common fundamentals. For this purpose analytical mechanics turns out to be very useful where D’Alembert’s principle in the Lagrangian formulation proves to be most efficient. The method of multibody systems, finite element systems and continuous systems are treated consistently. Thus, students get a much better understanding of dynamical phenomena, and engineers in design and development departments using computer codes may check the results more easily by choosing models of different complexity for vibration and stress analysis.

  14. Recycling of the Granite Quarries and Municipal Incinerator Wastes for the Processing of New Materials as Porcelainized Stoneware

    Directory of Open Access Journals (Sweden)

    Hernández-Crespo, M. S.

    2000-12-01

    Full Text Available In the 1980s started in the ceramic sector the material conception of porcelainized stoneware, a product with versatile and modern characteristics similar to those of the natural stone, depicting improved properties to the marble and granite. Porcelanized stoneware is a compact ceramic material, very hard and homogeneous, generally not fully vitreous (unglazed in its surface, obtained by fast firing from compositions enriched in kaolinite, which contain a large quantity of fluxes. The raw materials for body are a mixture that contains an adequate relationship of kaolinitic clays, feldspars and quartz. Such material is characterized by its low or almost zero porosity, being adequated to sustain heavy and high traffic intensity for uses in and outside of buildings with wide range of aspects, desings and colors. By considering the chemistry and mineralogical composition of the granite and incinerator wastes, this paper describes their use in the processing of construction materials, specifically, in a new type of stoneware flooring and covering materials. According to the most of the physical and mechanical properties here determined, these "Modified Porcelainized Stoneware" (MPS materials are close to the conventional porcelainized stoneware and glass ceramics products.

    Hacia la década de los años 80 se inicia en el sector cerámico la concepción del gres porcelánico, material de características modernas y versátiles semejantes a las de la piedra natural, pero que incluso supera en utilidad y prestaciones al mármol y al granito. El gres porcelánico es un material cerámico compacto, muy duro y homogéneo, no vidriado en su superficie, obtenido por cocción rápida de composiciones ricas en caolinita y una gran cantidad de fundentes; es decir, de una mezcla cerámica que contiene una relación adecuada de arcillas de tipo caolinítico, feldespatos y cuarzo. Dicho material se caracteriza por su baja o casi nula porosidad; es ideal

  15. A comparison on the marginal gap of two base metal alloys (Minalux, VeraBond2 during firing cycles of porcelain

    Directory of Open Access Journals (Sweden)

    Monzavi A.

    2004-06-01

    Full Text Available Statement of Problem: Nowadays economical issues on high gold alloys have changed the practice of metal-ceramic restorations toward base-metal alloys. Minalux is one of the base-metal alloys produced in Iran. Marginal fitness is of high importance to be evaluated in dental alloys."nPurpose: The aim of the present study was to compare the marginal adaptation of two base-metal alloys, Minalux (Mavadkaran Co. Iran and VeraBond2 (Aibadent Co. USA during firing cycles of porcelain. Materials and Methods: In an experimental study 24 standard brass dies, with 135° chamfer finishing line were fabricated by Computer Numeric Controlled (CNC milling machine. The samples were randomly divided in two groups, A and B, 12 in each. Following wax-up, the samples were equally cast with two mentioned alloys. In each group, there were 4 controlled samples, which proceeded to firing cycle without veneering porcelain. Scanning electron microscope (SEM measurements of marginal gap from buccal and lingual aspects were performed after 4 stages of casting, degassing, porcelain application and glazing. The data were analyzed using Four-way ANOVA and multiple comparative test based on Tukey criteria. Results: The findings of this study revealed that there was no significant difference in the marginal gap of Minalux (31.10±7.8u.m and VeraBond2 (30.27±6.96u.m with confidence level at 0.95 (P=0.43. For both alloys the greatest gap was observed after degassing stage (P<0.05. Porcelain and porcelain veneering proximity caused significant changes in the marginal gap of Minalux castings (P<0.05, however, such changes did not occur in VeraBond2 (PO.05."nConclusion: Based on the findings of this study, the marginal gaps of two base metal alloys, Minalux and VeraBond2, were proved to be identical and that of the Minalux alloy existed in the range of acceptable clinical application. It was also concluded that Minalux dental alloys could provide proper marginal adaptation.

  16. Clinical effect of porcelain veneer in treating discolored teeth%烤瓷贴面治疗变色牙的临床疗效

    Institute of Scientific and Technical Information of China (English)

    车道闯; 杨世艳; 车坚本

    2001-01-01

    AIM:To observe the clinical effect of porcelain veneer in treating discolored teeth. METHODS:116 and 106 discolored teeth were treated with porcelain veneer and composite veneer respectively, and compare their effects to each other. Clinical effect of color、appearance、function、sensation were checked after two years. RESULTS: The effet of porcelain veneer restoration is best in 84 cases(72.4%), better in 32 cases (27.60%). The effect of composite veneer restoration is best in 66 cases(62.26%), better in 25 cases(23.58%), failure in 15 cases(14.15%). CONCLUSION: The clinical effect of discolored teeth treated with porcelain veneer is better than that with composite veneer. But the long-term effect of porcelain veneer needs further research.%目的:观察烤瓷贴面治疗变色牙的临床疗效。方法:应用烤瓷贴面法治疗116个变色牙;并以复合树脂贴面治疗106个变色牙作对照。跟踪观察2年,比较其临床效果。结果:按颜色、外形、功能、感觉进行检查,用烤瓷贴面治疗者2年疗效优84牙(72.4%),一般32牙(27.6%)。用复合树脂治疗者2年疗效优66牙(62.26%),一般25牙(23.58%),失败15牙(14.15%)。结论:烤瓷贴面治疗变色牙的2年临床疗效较复合树脂贴面好,但远期疗效有待进一步研究。

  17. [Removal of an intratracheobronchial foreign body opaque to X-rays in a child within a context of inadequate medical technical equipment].

    Science.gov (United States)

    Horo, K; Kouassi, A B; Tea, B Z; Assa, L; Icthy, V M; Folquet, A; Godé, V C; Ahui, B J M; Cardenat, M; Achi, V; N'dhatz-Sanogo, M; Anon, J C; N'gouan, J M; N'gom, A; Koffi, N; Aka-Danguy, E

    2009-04-01

    Intratracheobronchial foreign bodies are common accidents in children. In developed countries, the removal of these intratracheobronchial foreign bodies is performed with flexible or rigid fiberoptic bronchoscopy. Resorting to surgery is rare. In the inadequate medical context described, suitable medical technical equipment doesn't exist. Removal alternatives are necessary in order to avoid sanitary evacuation which is not always within patients' means. In this study, the authors describe the removal of an intratracheobronchial foreign body opaque to X-rays with foreign body forceps. The forceps, passed through the orotracheal intubation probe, were guided by an image intensification system in a traumatology operating theatre.

  18. Near-field reflection backscattering apertureless optical microscopy: Application to spectroscopy experiments on opaque samples, comparison between lock-in and digital photon counting detection techniques

    Energy Technology Data Exchange (ETDEWEB)

    Diziain, S. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Bijeon, J.-L. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France)]. E-mail: bijeon@utt.fr; Adam, P.-M. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Lamy de la Chapelle, M. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Thomas, B. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Deturche, R. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France); Royer, P. [Institut Charles Delaunay, CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes cedex (France)

    2007-01-15

    An apertureless scanning near-field optical microscope (ASNOM) in reflection backscattering configuration is designed to conduct spectroscopic experiments on opaque samples constituted of latex beads. The ASNOM proposed takes advantage of the depth-discrimination properties of confocal microscopes to efficiently extract the near-field optical signal. Given their importance in a spectroscopic experiment, we systematically compare the lock-in and synchronous photon counting detection methods. Some results of Rayleigh's scattering in the near field of the test samples are used to illustrate the possibilities of this technique for reflection backscattering spectroscopy.

  19. Utilization of radiometric method in evaluation of wear on human dental enamel in vitro by dental porcelain glazed and polished; Utilizacao do metodo radiometrico na avaliacao in vitro do desgaste provocado ao esmalte dental humano por porcelanas dentais glazeadas e polidas

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Lena Katekawa; Campos, Tomie Nakakuki de; Adachi, Eduardo Makoto [Sao Paulo Univ., SP (Brazil). Faculdade de Odontologia. Dept. de Protese]. E-mail: katekawa@usp.br; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: mitiko@curiango.ipen.br

    2005-07-01

    The dental porcelain is a material commonly used in prosthesis. Disadvantages of dental porcelain use include possibility to cause tooth or dental materials wear. Before its use in the mouth, surfaces are treated with polishing and/or glazing. This research used the radiometric method to verify the influence of these surface treatments on the porcelains of commercial brands: Ceramco II, Noritake and Finesse. This method was originally developed for dentifrice abrasiveness evaluation. Five specimens of dental enamel and 10 specimens of each porcelain (5 glazed, 5 polished) were used. The dental enamel was flattened and irradiated with neutrons from the IEA-R1 (IPEN/CNEN) nuclear reactor. Then it was weared by each porcelain in sliding motion, with water. After 2,500 cycles for each porcelain specimen, the released enamel residue was measured. The enamel wear was evaluated by measuring beta activity of {sup 32}P transferred to water from the irradiated tooth. Results varied from 2.57 to 5.81 {mu}g of enamel /mm{sup 2} weared surface. There was no statistical difference ({alpha}=0.05) between dental enamel wear caused by the same porcelains glazed or polished. The results suggest that adequate surface finishing depend on the type of dental porcelain. (author)

  20. Environmental and human health assessment of life cycle of nanoTiO2 functionalized porcelain stoneware tile.

    Science.gov (United States)

    Pini, Martina; Bondioli, Federica; Montecchi, Rita; Neri, Paolo; Ferrari, Anna Maria

    2017-01-15

    Recently, there has been a rise in the interest in nanotechnology due to its enormous potential for the development of new products and applications with higher performance and new functionalities. However, while nanotechnology might revolutionize a number of industrial and consumer sectors, there are uncertainties and knowledge gaps regarding toxicological effects of this emerging science. The goal of this research concerns the implementation into Life Cycle Assessment (LCA) of preliminary frameworks developed to evaluate human toxicity and exposure factors related to the potential nanoparticle releases that could occur during the life cycle steps of a functionalized building material. The present LCA case study examines the ecodesign of nanoTiO2 functionalized porcelain stoneware tile production. The aim of this investigation is to manufacture new eco-friendly products in order to protect human health and ecosystem quality and to offer the market, materials with higher technological properties obtained by the addition of specific nanomaterials. Copyright © 2016 Elsevier B.V. All rights reserved.