WorldWideScience

Sample records for oneidensis mr-1 identification

  1. THE ROLE OF 4-HYDROXYPHENYLPYRUVATE DIOXYGENASE IN ENHANCEMENT OF SOLID-PHASE ELECTRON TRANSFER BY SHEWANELLA ONEIDENSIS MR-1

    Energy Technology Data Exchange (ETDEWEB)

    Turick, C; Amy Ekechukwu, A

    2007-06-01

    While mechanistic details of dissimilatory metal reduction are far from being understood, it is postulated that the electron transfer to solid metal oxides is mediated by outer membrane-associated c-type cytochromes and redox active electron shuttling compounds. This study focuses on the production of homogensitate in Shewanella oneidensis MR-1, an intermediate of tyrosine degradation pathway, which is a precursor of a redox cycling metabolite, pyomelanin. In this study, we determined that two enzymes involved in this pathway, 4-hydroxyphenylpyruvate dioxygenase (4HPPD) and homogentisate 1,2-dioxygenase are responsible for homogentisate production and oxidation, respectively. Inhibition of 4-HPPD activity with the specific inhibitor sulcotrione (2-(2-chloro-4-methane sulfonylbenzoyl)-1,3-cyclohexanedione), and deletion of melA, a gene encoding 4-HPPD, resulted in no pyomelanin production by S. oneidensis MR-1. Conversely, deletion of hmgA which encodes the putative homogentisate 1,2-dioxygenase, resulted in pyomelanin overproduction. The efficiency and rates, with which MR-1 reduces hydrous ferric oxide, were directly linked to the ability of mutant strains to produce pyomelanin. Electrochemical studies with whole cells demonstrated that pyomelanin substantially increases the formal potential (E{sup o}{prime}) of S. oneidensis MR-1. Based on this work, environmental production of pyomelanin likely contributes to an increased solid-phase metal reduction capacity in Shewanella oneidensis.

  2. Exploring the roles of DNA methylation in the metal-reducing bacterium Shewanella oneidensis MR-1

    Energy Technology Data Exchange (ETDEWEB)

    Bendall, Matthew L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Luong, Khai [Pacific Biosciences, Menlo Park, CA (United States); Wetmore, Kelly M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Blow, Matthew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Korlach, Jonas [Pacific Biosciences, Menlo Park, CA (United States); Deutschbauer, Adam [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Malmstrom, Rex [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-08-30

    We performed whole genome analyses of DNA methylation in Shewanella 17 oneidensis MR-1 to examine its possible role in regulating gene expression and 18 other cellular processes. Single-Molecule Real Time (SMRT) sequencing 19 revealed extensive methylation of adenine (N6mA) throughout the 20 genome. These methylated bases were located in five sequence motifs, 21 including three novel targets for Type I restriction/modification enzymes. The 22 sequence motifs targeted by putative methyltranferases were determined via 23 SMRT sequencing of gene knockout mutants. In addition, we found S. 24 oneidensis MR-1 cultures grown under various culture conditions displayed 25 different DNA methylation patterns. However, the small number of differentially 26 methylated sites could not be directly linked to the much larger number of 27 differentially expressed genes in these conditions, suggesting DNA methylation is 28 not a major regulator of gene expression in S. oneidensis MR-1. The enrichment 29 of methylated GATC motifs in the origin of replication indicate DNA methylation 30 may regulate genome replication in a manner similar to that seen in Escherichia 31 coli. Furthermore, comparative analyses suggest that many 32 Gammaproteobacteria, including all members of the Shewanellaceae family, may 33 also utilize DNA methylation to regulate genome replication.

  3. Starch-fueled microbial fuel cells by two-step and parallel fermentation using Shewanella oneidensis MR-1 and Streptococcus bovis 148.

    Science.gov (United States)

    Uno, Megumi; Phansroy, Nichanan; Aso, Yuji; Ohara, Hitomi

    2017-08-01

    Shewanella oneidensis MR-1 generates electricity from lactic acid, but cannot utilize starch. On the other hand, Streptococcus bovis 148 metabolizes starch and produces lactic acid. Therefore, two methods were trialed for starch-fueled microbial fuel cell (MFC) in this study. In electric generation by two-step fermentation (EGT) method, starch was first converted to lactic acid by S. bovis 148. The S. bovis 148 were then removed by centrifugation, and the fermented broth was preserved for electricity generation by S. oneidensis MR-1. Another method was electric generation by parallel fermentation (EGP) method. In this method, the cultivation and subsequent fermentation processes of S. bovis 148 and S. oneidensis MR-1 were performed simultaneously. After 1, 2, and 3 terms (5-day intervals) of S. oneidensis MR-1 in the EGT fermented broth of S. bovis 148, the maximum currents at each term were 1.8, 2.4, and 2.8 mA, and the maximum current densities at each term were 41.0, 43.6, and 49.9 mW/m 2 , respectively. In the EGP method, starch was also converted into lactic acid with electricity generation. The maximum current density was 140-200 mA/m 2 , and the maximum power density of this method was 12.1 mW/m 2 . Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  4. Invariability of Central Metabolic Flux Distribution in Shewanella oneidensis MR-1 Under Environmental or Genetic Perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yinjie; Martin, Hector Garcia; Deutschbauer, Adam; Feng, Xueyang; Huang, Rick; Llora, Xavier; Arkin, Adam; Keasling, Jay D.

    2009-04-21

    An environmentally important bacterium with versatile respiration, Shewanella oneidensis MR-1, displayed significantly different growth rates under three culture conditions: minimal medium (doubling time {approx} 3 hrs), salt stressed minimal medium (doubling time {approx} 6 hrs), and minimal medium with amino acid supplementation (doubling time {approx}1.5 hrs). {sup 13}C-based metabolic flux analysis indicated that fluxes of central metabolic reactions remained relatively constant under the three growth conditions, which is in stark contrast to the reported significant changes in the transcript and metabolite profiles under various growth conditions. Furthermore, ten transposon mutants of S. oneidensis MR-1 were randomly chosen from a transposon library and their flux distributions through central metabolic pathways were revealed to be identical, even though such mutational processes altered the secondary metabolism, for example, glycine and C1 (5,10-Me-THF) metabolism.

  5. High Pressure Reduction of Selenite by Shewanella oneidensis MR-1

    Science.gov (United States)

    Picard, A.; Daniel, I.; Testemale, D.; Letard, I.; Bleuet, P.; Cardon, H.; Oger, P.

    2007-12-01

    High-pressure biotopes comprise cold deep-sea environments, hydrothermal vents, and deep subsurface or deep-sea sediments. The latter are less studied, due to the technical difficulties to sample at great depths without contamination. Nevertheless, microbial sulfate reduction and methanogenesis have been found to be spatially distributed in deep deep-sea sediments (1), and sulfate reduction has been shown to be actually more efficient under high hydrostatic pressure (HHP) in some sediments (2). Sulfate-reducing bacteria obtained from the Japan Sea are characterized by an increased sulfide production under pressure (3,4). Unfortunately, investigations of microbial metabolic activity as a function of pressure are extremely scarce due to the experimental difficulty of such measurements at high hydrostatic pressure. We were able to measure the reduction of selenite Se(IV) by Shewanella oneidensis MR-1 as a function of pressure, to 150 MPa using two different high-pressure reactors that allow in situ X-ray spectroscopy measurements on a synchrotron source. A first series of measurements was carried out in a low-pressure Diamond Anvil Cell (DAC) of our own design (5) at ID22 beamline at ESRF (European Synchrotron Radiation Facility); a second one was performed in an autoclave (6) at the BM30B beamline at ESRF. Selenite reduction by strain MR-17 was monitored from ambient pressure to 150 MPa over 25 hours at 30 deg C by XANES spectroscopy (X-ray Analysis of Near Edge Structure). Spectra were recorded hourly in order to quantify the evolution of the oxidation state of selenium with time. Stationary-phase bacteria were inoculated at a high concentration into fresh growth medium containing 5 or 10 M of sodium selenite and 20 mM sodium lactate. Kinetic parameters of the Se (IV) reduction by Shewanella oneidensis strain MR-1 could be extracted from the data, as a function of pressure. They show 1) that the rate constant k of the reaction is decreased by a half at high pressure

  6. Photocatalytic properties of zinc sulfide nanocrystals biofabricated by metal-reducing bacterium Shewanella oneidensis MR-1

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Xiang [School of The Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090 (China); Ma, Xiao-Bo [School of The Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); Yuan, Hang [Key Laboratory of Ion Beam Bioengineering, Institute of Technical Biology & Agriculture Engineering, Chinese Academy of Sciences, Hefei 230031 (China); Liu, Peng-Cheng; Lei, Yu-Bin; Xu, Hui [School of The Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); Du, Dao-Lin, E-mail: ddl@ujs.edu.cn [School of The Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090 (China); Sun, Jian-Fan [School of The Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); Feng, Yu-Jie, E-mail: yujief@hit.edu.cn [State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090 (China)

    2015-05-15

    Highlights: • S. oneidensis MR-1 biofabricated ZnS nanocrystals using artificial wastewater. • ZnS nanocrystals were 5 nm in diameter and aggregated extracellularly. • ZnS had good catalytic activity in the degradation of RHB under UV irradiation. • Photogenerated holes mainly contributed to the degradation of RhB. - Abstract: Accumulation and utilization of heavy metals from wastewater by biological treatment system has aroused great interest. In the present study, a metal-reducing bacterium Shewanella oneidensis MR-1 was used to explore the biofabrication of ZnS nanocrystals from the artificial wastewater. The biogenic H{sub 2}S produced via the reduction of thiosulfate precipitated the Zn(II) as sulfide extracellularly. Characterization by X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), and field emission scanning electron microscope (FESEM) confirmed the precipitates as ZnS nanocrystals. The biogenic ZnS nanocrystals appeared spherical in shape with an average diameter of 5 nm and mainly aggregated in the medium and cell surface of S. oneidensis MR-1. UV–vis DRS spectra showed ZnS nanoparticles appeared a strong absorption below 360 nm. Thus, the photocatalytic activity of ZnS was evaluated by the photodegradation of rhodamine B (RhB) under UV irradiation. The biogenic ZnS nanocrystals showed a high level of photodegradation efficiency to RhB coupled with a significant blue-shift of maximum adsorption peak. A detailed analysis indicated the photogenerated holes, rather than hydroxyl radicals, contributed to the photocatalytic decolorization of RhB. This approach of coupling biosynthesis of nanoparticles with heavy metal removal may offer a potential avenue for efficient bioremediation of heavy metal wastewater.

  7. Photocatalytic properties of zinc sulfide nanocrystals biofabricated by metal-reducing bacterium Shewanella oneidensis MR-1

    International Nuclear Information System (INIS)

    Xiao, Xiang; Ma, Xiao-Bo; Yuan, Hang; Liu, Peng-Cheng; Lei, Yu-Bin; Xu, Hui; Du, Dao-Lin; Sun, Jian-Fan; Feng, Yu-Jie

    2015-01-01

    Highlights: • S. oneidensis MR-1 biofabricated ZnS nanocrystals using artificial wastewater. • ZnS nanocrystals were 5 nm in diameter and aggregated extracellularly. • ZnS had good catalytic activity in the degradation of RHB under UV irradiation. • Photogenerated holes mainly contributed to the degradation of RhB. - Abstract: Accumulation and utilization of heavy metals from wastewater by biological treatment system has aroused great interest. In the present study, a metal-reducing bacterium Shewanella oneidensis MR-1 was used to explore the biofabrication of ZnS nanocrystals from the artificial wastewater. The biogenic H 2 S produced via the reduction of thiosulfate precipitated the Zn(II) as sulfide extracellularly. Characterization by X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), and field emission scanning electron microscope (FESEM) confirmed the precipitates as ZnS nanocrystals. The biogenic ZnS nanocrystals appeared spherical in shape with an average diameter of 5 nm and mainly aggregated in the medium and cell surface of S. oneidensis MR-1. UV–vis DRS spectra showed ZnS nanoparticles appeared a strong absorption below 360 nm. Thus, the photocatalytic activity of ZnS was evaluated by the photodegradation of rhodamine B (RhB) under UV irradiation. The biogenic ZnS nanocrystals showed a high level of photodegradation efficiency to RhB coupled with a significant blue-shift of maximum adsorption peak. A detailed analysis indicated the photogenerated holes, rather than hydroxyl radicals, contributed to the photocatalytic decolorization of RhB. This approach of coupling biosynthesis of nanoparticles with heavy metal removal may offer a potential avenue for efficient bioremediation of heavy metal wastewater

  8. Molecular Underpinnings of Fe(III Oxide Reduction by Shewanella oneidensis MR-1

    Directory of Open Access Journals (Sweden)

    Liang eShi

    2012-02-01

    Full Text Available In the absence of O2 and other electron acceptors, the Gram-negative bacterium Shewanella oneidensis MR-1 can use ferric [Fe(III] (oxy(hydroxide minerals as the terminal electron acceptors for anaerobic respiration. At circumneutral pH and in the absence of strong complexing ligands, Fe(III oxides are relatively insoluble and thus are external to the bacterial cells. S. oneidensis MR-1 has evolved the machinery (i.e., metal-reducing or Mtr pathway for transferring electrons across the entire cell envelope to the surface of extracellular Fe(III oxides. The protein components identified to date for the Mtr pathway include CymA, MtrA, MtrB, MtrC and OmcA. CymA is an inner-membrane tetraheme c-type cytochrome (c-Cyt that is proposed to oxidize the quinol in the inner-membrane and transfers the released electrons to redox proteins in the periplasm. Although the periplasmic proteins receiving electrons from CymA during Fe(III oxidation have not been identified, they are believed to relay the electrons to MtrA. A decaheme c-Cyt, MtrA is thought to be embedded in the trans outer-membrane and porin-like protein MtrB. Together, MtrAB deliver the electrons across the outer-membrane to the MtrC and OmcA on the outmost bacterial surface. Functioning as terminal reductases, the outer membrane and decaheme c-Cyts MtrC and OmcA can bind the surface of Fe(III oxides and transfer electrons directly to these minerals. To increase their reaction rates, MtrC and OmcA can use the flavins secreted by S. oneidensis MR-1 cells as diffusible co-factors for reduction of Fe(III oxides. MtrC and OmcA can also serve as the terminal reductases for soluble forms of Fe(III. Although our understanding of the Mtr pathway is still far from complete, it is the best characterized microbial pathway used for extracellular electron exchange. Characterizations of the Mtr pathway have made significant contributions to the molecular understanding of microbial reduction of Fe(III oxides.

  9. Electrochemical Measurement of Electron Transfer Kinetics by Shewanella oneidensis MR-1*

    Science.gov (United States)

    Baron, Daniel; LaBelle, Edward; Coursolle, Dan; Gralnick, Jeffrey A.; Bond, Daniel R.

    2009-01-01

    Shewanella oneidensis strain MR-1 can respire using carbon electrodes and metal oxyhydroxides as electron acceptors, requiring mechanisms for transferring electrons from the cell interior to surfaces located beyond the cell. Although purified outer membrane cytochromes will reduce both electrodes and metals, S. oneidensis also secretes flavins, which accelerate electron transfer to metals and electrodes. We developed techniques for detecting direct electron transfer by intact cells, using turnover and single turnover voltammetry. Metabolically active cells attached to graphite electrodes produced thin (submonolayer) films that demonstrated both catalytic and reversible electron transfer in the presence and absence of flavins. In the absence of soluble flavins, electron transfer occurred in a broad potential window centered at ∼0 V (versus standard hydrogen electrode), and was altered in single (ΔomcA, ΔmtrC) and double deletion (ΔomcA/ΔmtrC) mutants of outer membrane cytochromes. The addition of soluble flavins at physiological concentrations significantly accelerated electron transfer and allowed catalytic electron transfer to occur at lower applied potentials (−0.2 V). Scan rate analysis indicated that rate constants for direct electron transfer were slower than those reported for pure cytochromes (∼1 s−1). These observations indicated that anodic current in the higher (>0 V) window is due to activation of a direct transfer mechanism, whereas electron transfer at lower potentials is enabled by flavins. The electrochemical dissection of these activities in living cells into two systems with characteristic midpoint potentials and kinetic behaviors explains prior observations and demonstrates the complementary nature of S. oneidensis electron transfer strategies. PMID:19661057

  10. Involvement of Shewanella oneidensis MR-1 LuxS in Biofilm Development and Sulfur Metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Learman, Deric R.; Yi, Haakrho; Brown, Steven D.; Martin, Stanton L.; Geesey, Gill G.; Stevens, Ann M.; Hochella, Michael F.

    2009-01-05

    The role of LuxS in Shewanella oneidensis MR-1 has been examined by transcriptomic profiling, biochemical, and physiological experiments. The results indicate that a mutation in luxS alters biofilm development, not by altering quorum-sensing abilities but by disrupting the activated methyl cycle (AMC). The S. oneidensis wild type can produce a luminescence response in the AI-2 reporter strain Vibrio harveyi MM32. This luminescence response is abolished upon the deletion of luxS. The deletion of luxS also alters biofilm formations in static and flowthrough conditions. Genetic complementation restores the mutant biofilm defect, but the addition of synthetic AI-2 has no effect. These results suggest that AI-2 is not used as a quorum-sensing signal to regulate biofilm development in S. oneidensis. Growth on various sulfur sources was examined because of the involvement of LuxS in the AMC. A mutation in luxS produced a reduced ability to grow with methionine as the sole sulfur source. Methionine is a key metabolite used in the AMC to produce a methyl source in the cell and to recycle homocysteine. These data suggest that LuxS is important to metabolizing methionine and the AMC in S. oneidensis.

  11. Integrated Analysis of Protein Complexes and Regulatory Networks Involved in Anaerobic Energy Metabolism of Shewanella Oneidensis MR-1

    Energy Technology Data Exchange (ETDEWEB)

    Tiedje, James M.

    2005-06-01

    Anaerobic Nitrate Reduction. Nitrate is an extensive co-contaminant at some DOE sites making metal and radionuclide reduction problematic. Hence, we sought to better understand the nitrate reduction pathway and its control in S. oneidensis MR-1. It is not known whether the nitrate reduction is by denitrification or dissimilatory nitrate reduction into ammonium (DNRA). By both physiological and genetic evidence, we proved that DNRA is the nitrate reduction pathway in this organism. Using the complete genome sequence of S. oneidensis MR-1, we identified a gene encoding a periplasmic nitrate reductase based on its 72% sequence identity with the napA gene in E. coli. Anaerobic growth of MR-1 on nitrate was abolished in a site directed napA mutant, indicating that NapA is the only nitrate reductase present. The anaerobic expression of napA and nrfA, a homolog of the cytochrome b552 nitrite reductase in E. coli, increased with increasing nitrate concentration until a plateau was reached at 3 mM KNO3. This indicates that these genes are not repressed by increasing concentrations of nitrate. The reduction of nitrate can generate intermediates that can be toxic to the microorganism. To determine the genetic response of MR-1 to high concentrations of nitrate, DNA microarrays were used to obtain a complete gene expression profile of MR-1 at low (1 mM) versus high (40 mM) nitrate concentrations. Genes encoding transporters and efflux pumps were up-regulated, perhaps as a mechanism to export toxic compounds. In addition, the gene expression profile of MR-1, grown anaerobically with nitrate as the only electron acceptor, suggested that this dissimilatory pathway contributes to N assimilation. Hence the nitrate reduction pathway could serve a dual purpose. The role of EtrA, a homolog of Fnr (global anaerobic regulator in E. coli) was examined using an etrA deletion mutant we constructed, S. oneidensis EtrA7-1.

  12. Enzymatic reduction of U60 nanoclusters by Shewanella oneidensis MR-1

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Qiang; Fein, Jeremy B. [Notre Dame Univ., IN (United States). Dept. of Civil and Environmental Engineering and Earth Sciences

    2018-04-01

    In this study, a series of reduction experiments were conducted using a representative uranyl peroxide nanocluster, U60 (K{sub 16}Li{sub 44}[UO{sub 2}(O{sub 2})OH]{sub 60}) and a bacterial species, Shewanella oneidensis MR-1, that is capable of enzymatic U(VI) reduction. U60 was reduced by S. oneidensis in the absence of O{sub 2}, but the reduction kinetics for U60 were significantly slower than was observed in this study for aqueous uranyl acetate, and were faster than was reported in previous studies for solid phase U(VI). Our results indicate that U60 aggregates bigger than 0.2 μm formed immediately upon mixing with the bacterial growth medium, and that these aggregates were gradually broken down during the process of reduction. Neither reduction nor dissolution of U60 was observed during 72 h of control experiments open to the atmosphere, indicating that the breakdown and dissolution of U60 aggregates is caused by the reduction of U60, and that S. oneidensis is capable of direct reduction of the U(VI) within the U60 nanoclusters, likely due to the adsorption of U60 aggregates onto bacterial cells. This study is first to show the reduction capacity of bacteria for uranyl peroxide nanoclusters, and the results yield a better understanding of the long term fate of uranium in environmental systems in which uranyl peroxide nanoclusters are present.

  13. Regulation of Gene Expression in Shewanella oneidensis MR-1 during Electron Acceptor Limitation and Bacterial Nanowire Formation

    Science.gov (United States)

    Barchinger, Sarah E.; Pirbadian, Sahand; Baker, Carol S.; Leung, Kar Man; Burroughs, Nigel J.; El-Naggar, Mohamed Y.

    2016-01-01

    ABSTRACT In limiting oxygen as an electron acceptor, the dissimilatory metal-reducing bacterium Shewanella oneidensis MR-1 rapidly forms nanowires, extensions of its outer membrane containing the cytochromes MtrC and OmcA needed for extracellular electron transfer. RNA sequencing (RNA-Seq) analysis was employed to determine differential gene expression over time from triplicate chemostat cultures that were limited for oxygen. We identified 465 genes with decreased expression and 677 genes with increased expression. The coordinated increased expression of heme biosynthesis, cytochrome maturation, and transport pathways indicates that S. oneidensis MR-1 increases cytochrome production, including the transcription of genes encoding MtrA, MtrC, and OmcA, and transports these decaheme cytochromes across the cytoplasmic membrane during electron acceptor limitation and nanowire formation. In contrast, the expression of the mtrA and mtrC homologs mtrF and mtrD either remains unaffected or decreases under these conditions. The ompW gene, encoding a small outer membrane porin, has 40-fold higher expression during oxygen limitation, and it is proposed that OmpW plays a role in cation transport to maintain electrical neutrality during electron transfer. The genes encoding the anaerobic respiration regulator cyclic AMP receptor protein (CRP) and the extracytoplasmic function sigma factor RpoE are among the transcription factor genes with increased expression. RpoE might function by signaling the initial response to oxygen limitation. Our results show that RpoE activates transcription from promoters upstream of mtrC and omcA. The transcriptome and mutant analyses of S. oneidensis MR-1 nanowire production are consistent with independent regulatory mechanisms for extending the outer membrane into tubular structures and for ensuring the electron transfer function of the nanowires. IMPORTANCE Shewanella oneidensis MR-1 has the capacity to transfer electrons to its external surface

  14. The Shewanella oneidensis MR-1 Fluxome under Various OxygenConditions

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yinjie J.; Hwang, Judy S.; Wemmer, David E.; Keasling, Jay D.

    2006-03-17

    The central metabolic fluxes of Shewanella oneidensis MR-1were examined under carbon-limited (aerobic) and oxygen-limited(micro-aerobic) chemostat conditions using 13C labeled lactate as thesole carbon source. The carbon labeling patterns of key amino acids inbiomass were probed using both GC-MS and 13C-NMR. Based on the genomeannotation, a metabolic pathway model was constructed to quantify thecentral metabolic flux distributions. The model showed that thetricarboxylic acid (TCA) cycle is the major carbon metabolism route underboth conditions. The Entner-Doudoroff and pentose phosphate pathways weremainly utilized for biomass synthesis (flux below 5 percent of thelactate uptake rate). The anapleurotic reactions (pyruvate to malate andoxaloacetate to phosphoenolpyruvate) and the glyoxylate shunt wereactive. Under carbon-limited conditions, a substantial amount of carbonwas oxidized via the highly reversible serine metabolic pathway. Fluxesthrough the TCA cycle were less whereas acetate production was more underoxygen limitation than under carbon limitation. Although fluxdistributions under aerobic, micro-aerobic, and shake-flask cultureconditions were dramatically different, the relative flux ratios of thecentral metabolic reactions did not vary significantly. Hence, S.oneidensis metabolism appears to be quite robust to environmentalchanges. Our study also demonstrates the merit of coupling GC-MS with 13CNMR for metabolic flux analysis to reduce the use of 13C labeledsubstrates and to obtain more accurate flux values.

  15. Effects of Cd on reductive transformation of lepidocrocite by Shewanella oneidensis MR-1

    Institute of Scientific and Technical Information of China (English)

    Chaolei Yuan; Fangbai Li; Rui Han; Tongxu Liu; Weimin Sun; Weilin Huang

    2017-01-01

    We investigated the reduction of lepidocrocite (γ-FeOOH) by Shewanella oneidensis MR-1 in the presence and absence of Cd.The results showed that Cd2+ retarded microbial reduction of γ-FeOOH and avoided formation of magnetite.The inhibitory effect on γ-FeOOH transformation may not result from Cd2+ toxicity to the bacterium;it rather was probably due to competitive adsorption between Cd2+ and Fe2+ on γ-FeOOH as its surface reduction catalyzed by adsorbed Fe2+ was eliminated by adsorption of Cd2+.

  16. Constraint-based model of Shewanella oneidensis MR-1 metabolism: a tool for data analysis and hypothesis generation.

    Directory of Open Access Journals (Sweden)

    Grigoriy E Pinchuk

    2010-06-01

    Full Text Available Shewanellae are gram-negative facultatively anaerobic metal-reducing bacteria commonly found in chemically (i.e., redox stratified environments. Occupying such niches requires the ability to rapidly acclimate to changes in electron donor/acceptor type and availability; hence, the ability to compete and thrive in such environments must ultimately be reflected in the organization and utilization of electron transfer networks, as well as central and peripheral carbon metabolism. To understand how Shewanella oneidensis MR-1 utilizes its resources, the metabolic network was reconstructed. The resulting network consists of 774 reactions, 783 genes, and 634 unique metabolites and contains biosynthesis pathways for all cell constituents. Using constraint-based modeling, we investigated aerobic growth of S. oneidensis MR-1 on numerous carbon sources. To achieve this, we (i used experimental data to formulate a biomass equation and estimate cellular ATP requirements, (ii developed an approach to identify cycles (such as futile cycles and circulations, (iii classified how reaction usage affects cellular growth, (iv predicted cellular biomass yields on different carbon sources and compared model predictions to experimental measurements, and (v used experimental results to refine metabolic fluxes for growth on lactate. The results revealed that aerobic lactate-grown cells of S. oneidensis MR-1 used less efficient enzymes to couple electron transport to proton motive force generation, and possibly operated at least one futile cycle involving malic enzymes. Several examples are provided whereby model predictions were validated by experimental data, in particular the role of serine hydroxymethyltransferase and glycine cleavage system in the metabolism of one-carbon units, and growth on different sources of carbon and energy. This work illustrates how integration of computational and experimental efforts facilitates the understanding of microbial metabolism at a

  17. Shewanella oneidensis MR-1 nanowires are outer membrane and periplasmic extensions of the extracellular electron transport components.

    Science.gov (United States)

    Pirbadian, Sahand; Barchinger, Sarah E; Leung, Kar Man; Byun, Hye Suk; Jangir, Yamini; Bouhenni, Rachida A; Reed, Samantha B; Romine, Margaret F; Saffarini, Daad A; Shi, Liang; Gorby, Yuri A; Golbeck, John H; El-Naggar, Mohamed Y

    2014-09-02

    Bacterial nanowires offer an extracellular electron transport (EET) pathway for linking the respiratory chain of bacteria to external surfaces, including oxidized metals in the environment and engineered electrodes in renewable energy devices. Despite the global, environmental, and technological consequences of this biotic-abiotic interaction, the composition, physiological relevance, and electron transport mechanisms of bacterial nanowires remain unclear. We report, to our knowledge, the first in vivo observations of the formation and respiratory impact of nanowires in the model metal-reducing microbe Shewanella oneidensis MR-1. Live fluorescence measurements, immunolabeling, and quantitative gene expression analysis point to S. oneidensis MR-1 nanowires as extensions of the outer membrane and periplasm that include the multiheme cytochromes responsible for EET, rather than pilin-based structures as previously thought. These membrane extensions are associated with outer membrane vesicles, structures ubiquitous in Gram-negative bacteria, and are consistent with bacterial nanowires that mediate long-range EET by the previously proposed multistep redox hopping mechanism. Redox-functionalized membrane and vesicular extensions may represent a general microbial strategy for electron transport and energy distribution.

  18. Elucidating the Molecular Basis and Regulation of Chromium (VI) Reduction by Shewanella oneidensis MR-1 Using Biochemical, Genomic, and Proteomic Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Hettich, Robert L.

    2006-10-30

    Although microbial metal reduction has been investigated intensively from physiological and biochemical perspectives, little is known about the genetic basis and regulatory mechanisms underlying the ability of certain bacteria to transform, detoxify, or immobilize a wide array of heavy metals contaminating DOE-relevant environments. The major goal of this work is to elucidate the molecular components comprising the chromium(VI) response pathway, with an emphasis on components involved in Cr(VI) detoxification and the enzyme complex catalyzing the terminal step in Cr(VI) reduction by Shewanella oneidensis MR-1. We have identified and characterized (in the case of DNA-binding response regulator [SO2426] and a putative azoreductase [SO3585]) the genes and gene products involved in the molecular response of MR-1 to chromium(VI) stress using whole-genome sequence information for MR-1 and recently developed proteomic technology, in particular liquid chromatographymass spectrometry (LC-MS), in conjunction with conventional protein purification and characterization techniques. The proteome datasets were integrated with information from whole-genome expression arrays for S. oneidensis MR-1 (as illustrated in Figure 1). The genes and their encoded products identified in this study are of value in understanding metal reduction and bacterial resistance to metal toxicity and in developing effective metal immobilization strategies.

  19. Ferrihydrite-associated organic matter (OM stimulates reduction by Shewanella oneidensis MR-1 and a complex microbial consortia

    Directory of Open Access Journals (Sweden)

    R. E. Cooper

    2017-11-01

    Full Text Available The formation of Fe(III oxides in natural environments occurs in the presence of natural organic matter (OM, resulting in the formation of OM–mineral complexes that form through adsorption or coprecipitation processes. Thus, microbial Fe(III reduction in natural environments most often occurs in the presence of OM–mineral complexes rather than pure Fe(III minerals. This study investigated to what extent does the content of adsorbed or coprecipitated OM on ferrihydrite influence the rate of Fe(III reduction by Shewanella oneidensis MR-1, a model Fe(III-reducing microorganism, in comparison to a microbial consortium extracted from the acidic, Fe-rich Schlöppnerbrunnen fen. We found that increased OM content led to increased rates of microbial Fe(III reduction by S. oneidensis MR-1 in contrast to earlier findings with the model organism Geobacter bremensis. Ferrihydrite–OM coprecipitates were reduced slightly faster than ferrihydrites with adsorbed OM. Surprisingly, the complex microbial consortia stimulated by a mixture of electrons donors (lactate, acetate, and glucose mimics S. oneidensis under the same experimental Fe(III-reducing conditions suggesting similar mechanisms of electron transfer whether or not the OM is adsorbed or coprecipitated to the mineral surfaces. We also followed potential shifts of the microbial community during the incubation via 16S rRNA gene sequence analyses to determine variations due to the presence of adsorbed or coprecipitated OM–ferrihydrite complexes in contrast to pure ferrihydrite. Community profile analyses showed no enrichment of typical model Fe(III-reducing bacteria, such as Shewanella or Geobacter sp., but an enrichment of fermenters (e.g., Enterobacteria during pure ferrihydrite incubations which are known to use Fe(III as an electron sink. Instead, OM–mineral complexes favored the enrichment of microbes including Desulfobacteria and Pelosinus sp., both of which can utilize lactate and

  20. Ferrihydrite-associated organic matter (OM) stimulates reduction by Shewanella oneidensis MR-1 and a complex microbial consortia

    Science.gov (United States)

    Cooper, Rebecca Elizabeth; Eusterhues, Karin; Wegner, Carl-Eric; Totsche, Kai Uwe; Küsel, Kirsten

    2017-11-01

    The formation of Fe(III) oxides in natural environments occurs in the presence of natural organic matter (OM), resulting in the formation of OM-mineral complexes that form through adsorption or coprecipitation processes. Thus, microbial Fe(III) reduction in natural environments most often occurs in the presence of OM-mineral complexes rather than pure Fe(III) minerals. This study investigated to what extent does the content of adsorbed or coprecipitated OM on ferrihydrite influence the rate of Fe(III) reduction by Shewanella oneidensis MR-1, a model Fe(III)-reducing microorganism, in comparison to a microbial consortium extracted from the acidic, Fe-rich Schlöppnerbrunnen fen. We found that increased OM content led to increased rates of microbial Fe(III) reduction by S. oneidensis MR-1 in contrast to earlier findings with the model organism Geobacter bremensis. Ferrihydrite-OM coprecipitates were reduced slightly faster than ferrihydrites with adsorbed OM. Surprisingly, the complex microbial consortia stimulated by a mixture of electrons donors (lactate, acetate, and glucose) mimics S. oneidensis under the same experimental Fe(III)-reducing conditions suggesting similar mechanisms of electron transfer whether or not the OM is adsorbed or coprecipitated to the mineral surfaces. We also followed potential shifts of the microbial community during the incubation via 16S rRNA gene sequence analyses to determine variations due to the presence of adsorbed or coprecipitated OM-ferrihydrite complexes in contrast to pure ferrihydrite. Community profile analyses showed no enrichment of typical model Fe(III)-reducing bacteria, such as Shewanella or Geobacter sp., but an enrichment of fermenters (e.g., Enterobacteria) during pure ferrihydrite incubations which are known to use Fe(III) as an electron sink. Instead, OM-mineral complexes favored the enrichment of microbes including Desulfobacteria and Pelosinus sp., both of which can utilize lactate and acetate as an electron

  1. Iron Triggers λSo Prophage Induction and Release of Extracellular DNA in Shewanella oneidensis MR-1 Biofilms

    OpenAIRE

    Binnenkade, Lucas; Teichmann, Laura; Thormann, Kai M.

    2014-01-01

    Prophages are ubiquitous elements within bacterial chromosomes and affect host physiology and ecology in multiple ways. We have previously demonstrated that phage-induced lysis is required for extracellular DNA (eDNA) release and normal biofilm formation in Shewanella oneidensis MR-1. Here, we investigated the regulatory mechanisms of prophage λSo spatiotemporal induction in biofilms. To this end, we used a functional fluorescence fusion to monitor λSo activation in various mutant backgrounds...

  2. Reconstruction of Extracellular Respiratory Pathways for Iron(III Reduction in Shewanella oneidensis strain MR-1

    Directory of Open Access Journals (Sweden)

    Dan eCoursolle

    2012-02-01

    Full Text Available Shewanella oneidensis strain MR-1 is a facultative anaerobic bacterium capable of respiring a multitude of electron acceptors, many of which require the Mtr respiratory pathway. The core Mtr respiratory pathway includes a periplasmic c-type cytochrome (MtrA, an integral outer membrane β-barrel protein (MtrB and an outer membrane-anchored c-type cytochrome (MtrC. Together, these components facilitate transfer of electrons from the c-type cytochrome CymA in the cytoplasmic membrane to electron acceptors at and beyond the outer membrane. The genes encoding these core proteins have paralogs in the S. oneidensis genome (mtrB and mtrA each have four while mtrC has three and some of the paralogs of mtrC and mtrA are able to form functional Mtr complexes. We demonstrate that of the additional three mtrB paralogs found in the S. oneidensis genome, only MtrE can replace MtrB to form a functional respiratory pathway to soluble iron(III citrate. We also evaluate which mtrC / mtrA paralog pairs (a total of 12 combinations are able to form functional complexes with endogenous levels of mtrB paralog expression. Finally, we reconstruct all possible functional Mtr complexes and test them in a S. oneidensis mutant strain where all paralogs have been eliminated from the genome. We find that each combination tested with the exception of MtrA / MtrE / OmcA is able to reduce iron(III citrate at a level significantly above background. The results presented here have implications towards the evolution of anaerobic extracellular respiration in Shewanella and for future studies looking to increase the rates of substrate reduction for water treatment, bioremediation, or electricity production.

  3. Electrochemical Catalysis of Inorganic Complex K4[Fe(CN)6] by Shewanellaoneidensis MR-1

    DEFF Research Database (Denmark)

    Zheng, Zhiyong; Wu, Ranran; Xiao, Yong

    The interaction between metal and bacteria is a universal and important biogeochemical processin environment. As a dissimilatory metal reduction bacterium, the electrochemically activebacteriium Shewanella oneidensis MR-1 can transfer intracellular electrons to minerals. This ability is attribute...... andelectrocatalysis mechanisms of S. oneidensis MR-1 are under investigation. The ability of S. oneidensis MR-1 to catalyze redoxaction of inorganic metal complex compounds will provide an insight on metal cycles in nature....

  4. Elucidating the Molecular Basis and Regulation of Chromium(VI) Reduction by Shewanella oneidensis MR-1 and Resistance to Metal Toxicity Using Integrated Biochemical, Genomic and Proteomic Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Dorothea K. Thompson; Robert Hettich

    2007-02-06

    Shewanella oneidensis MR-1 is a model environmental organism that possesses diverse respiratory capacities, including the ability to reduce soluble Cr(VI) to sparingly soluble, less toxic Cr(III). Chromate is a serious anthropogenic pollutant found in subsurface sediment and groundwater environments due to its widespread use in defense and industrial applications. Effective bioremediation of chromate-contaminated sites requires knowledge of the molecular mechanisms and regulation of heavy metal resistance and biotransformation by dissimilatory metal-reducing bacteria. Towards this goal, our ERSP-funded work was focused on the identification and functional analysis of genes/proteins comprising the response pathways for chromate detoxification and/or reduction. Our work utilized temporal transcriptomic profiling and whole-cell proteomic analyses to characterize the dynamic molecular response of MR-1 to an acute chromate shock (up to 90 min) as well as to a 24-h, low-dose exposure. In addition, we have examined the transcriptome of MR-1 cells actively engaged in chromate reduction. These studies implicated the involvement of a functionally undefined DNA-binding response regulator (SO2426) and a putative azoreductase (SO3585) in the chromate stress response of MR-1.

  5. Transcriptome and metabolome responses of Shewanella oneidensis MR-1 to methyl orange under microaerophilic and aerobic conditions.

    Science.gov (United States)

    Cao, Xinhua; Qi, Yueling; Xu, Chen; Yang, Yuyi; Wang, Jun

    2017-04-01

    Shewanella oneidensis MR-1 degrades various azo dyes under microaerophilic and anaerobic conditions, but this process is inhibited under aerobic conditions. The mechanisms underlying azo dye biodegradation and inhibition remain unknown. Therefore, we investigated metabolic and transcriptional changes in strain MR-1, which was cultured under different conditions, to elucidate these mechanisms. At the transcriptional level, genes involved in certain metabolic processes, particularly the tricarboxylic acid (TCA) cycle, amino acid biodegradation, and the electron transfer system, were significantly altered (M ≧ 2, p > 0.8 ) in the presence of methyl orange (MO). Moreover, a high concentration of dissolved oxygen heavily impacted the expression levels of genes involved in fatty acid biodegradation. Metabolome analysis revealed significant alteration (p < 0.05) in the concentrations of nine metabolites when strain MR-1 was cultured under aerobic conditions; the majority of these metabolites were closely associated with amino acid metabolism and DNA replication. Accordingly, we propose a possible pathway for MO biodegradation and discuss the most likely causes of biodegradation inhibition due to dissolved oxygen.

  6. Catabolic and regulatory systems in Shewanella oneidensis MR-1 involved in electricity generation in microbial fuel cells

    Directory of Open Access Journals (Sweden)

    Atsushi eKouzuma

    2015-06-01

    Full Text Available Shewanella oneidensis MR-1 is a facultative anaerobe that respires using a variety of inorganic and organic compounds. MR-1 is also capable of utilizing extracellular solid materials, including anodes in microbial fuel cells (MFCs, as electron acceptors, thereby enabling electricity generation. As MFCs have the potential to generate electricity from biomass waste and wastewater, MR-1 has been extensively studied to identify the molecular systems that are involved in electricity generation in MFCs. These studies have demonstrated the importance of extracellular electron-transfer pathways that electrically connect the quinone pool in the cytoplasmic membrane to extracellular electron acceptors. Electricity generation is also dependent on intracellular catabolic pathways that oxidize electron donors, such as lactate, and regulatory systems that control the expression of genes encoding the components of catabolic and electron-transfer pathways. In addition, recent findings suggest that cell-surface polymers, e.g., exopolysaccharides, and secreted chemicals, which function as electron shuttles, are also involved in electricity generation. Despite these advances in our knowledge on the extracellular electron-transfer processes in MR-1, further efforts are necessary to fully understand the underlying intra- and extra-cellular molecular systems for electricity generation in MFCs. We suggest that investigating how MR-1 coordinates these systems to efficiently transfer electrons to electrodes and conserve electrochemical energy for cell proliferation is important for establishing the biological bases for MFCs.

  7. In-vivo identification of direct electron transfer from Shewanella oneidensis MR-1 to electrodes via outer-membrane OmcA-MtrCAB protein complexes

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Akihiro [Department of Applied Chemistry, School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Nakamura, Ryuhei, E-mail: nakamura@light.t.u-tokyo.ac.jp [Department of Applied Chemistry, School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Hashimoto, Kazuhito, E-mail: hashimoto@light.t.u-tokyo.ac.jp [Department of Applied Chemistry, School of Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); ERATO/JST, HASHIMOTO Light Energy Conversion Project (Japan)

    2011-06-30

    Graphical abstract: . Display Omitted Highlights: > Monolayer biofilm of Shewanella cells was prepared on an ITO electrode. > Extracellular electron transfer (EET) process was examined with series of mutants. > Direct ET was confirmed with outer-membrane-bound OmcA-MtrCAB complex. > The EET process was not prominently influenced by capsular polysaccharide. - Abstract: The direct electron-transfer (DET) property of Shewanella bacteria has not been resolved in detail due to the complexity of in vivo electrochemistry in whole-cell systems. Here, we report the in vivo assignment of the redox signal indicative of the DET property in biofilms of Shewanella oneidensis MR-1 by cyclic voltammetry (CV) with a series of mutants and a chemical marking technique. The CV measurements of monolayer biofilms formed by deletion mutants of c-type cytochromes ({Delta}mtrA, {Delta}mtrB, {Delta}mtrC/{Delta}omcA, and {Delta}cymA), and pilin ({Delta}pilD), capsular polysaccharide ({Delta}SO3177) and menaquinone ({Delta}menD) biosynthetic proteins demonstrated that the electrochemical redox signal with a midpoint potential at 50 mV (vs. SHE) was due to an outer-membrane-bound OmcA-MtrCAB protein complex of decaheme cytochromes, and did not involve either inner-membrane-bound CymA protein or secreted menaquinone. Using the specific binding affinity of nitric monoxide for the heme groups of c-type cytochromes, we further confirmed this conclusion. The heterogeneous standard rate constant for the DET process was estimated to be 300 {+-} 10 s{sup -1}, which was two orders of magnitude higher than that previously reported for the electron shuttling process via riboflavin. Experiments using a mutant unable to produce capsular polysaccharide ({Delta}SO3177) revealed that the DET property of the OmcA-MtrCAB complex was not influenced by insulating and hydrophilic extracellular polysaccharide. Accordingly, under physiological conditions, S. oneidensis MR-1 utilizes a high density of outer

  8. Cu-doped TiO2 nanoparticles enhance survival of Shewanella oneidensis MR-1 under Ultraviolet Light (UV) exposure

    International Nuclear Information System (INIS)

    Wu, Bing; Zhuang, Wei-Qin; Sahu, Manoranjan; Biswas, Pratim; Tang, Yinjie J.

    2011-01-01

    It has been shown that photocatalytic TiO 2 nanoparticles (NPs) can be used as an efficient anti-microbial agent under UV light due to generation of reactive oxygen species (ROS), while Shewanella oneidensis MR-1 is a metal-reducing bacterium highly susceptible to UV radiation. Interestingly, we found that the presence of Cu-doped TiO 2 NPs in the cultural medium dramatically increased the survival rates (based on colony-forming unit) of strain MR-1 by over 10,000-fold (incubation without shaking) and ∼ 200 fold (incubation with shaking) after a 2-h exposure to UV light. Gene expression results (via qPCR measurement) indicated that the DNA repair gene recA in MR-1 was significantly induced by UV exposure (indicating cellular damage under UV stress), but the influence of NPs on recA expression was not statistically evident. Plausible explanations to NP attenuation of UV stresses are: 1. TiO 2 based NPs are capable of scattering and absorbing UV light and thus create a shading effect to protect MR-1 from UV radiation; 2. more importantly, Cu-doped TiO 2 NPs can co-agglomerate with MR-1 to form large flocs that improves cells' survival against the environmental stresses. This study improves our understanding of NP ecological impacts under natural solar radiation and provides useful insights to application of photocatalytic-NPs for bacterial disinfection.

  9. Selective electrocatalysis of biofuel molecular oxidation using palladium nanoparticles generated on Shewanella oneidensis MR-1

    DEFF Research Database (Denmark)

    Wu, Ranran; Tian, Xiaochun; Xiao, Yong

    2018-01-01

    of formate with 200 mV less over-potential. Notably they show unique selective activity toward electrochemical oxidation of formate, whereas no electrochemical catalysis was found for oxidation of ethanol, methanol and acetate. This work demonstrates a sustainable and low-cost method for producing efficient......Production of molecular scale palladium (Pd) nanoparticles (NPs) is important due to their catalytic function in electrochemical oxidation of a number of core fuel molecules in fuel cells. Biogenic methods offer an economic and environmentally friendly synthesis route. In this work...... membrane surface. Mapping by conductive atomic force microscopy shows that the presence of these PdNPs promotes electron transfer and enhances the electric conductivity of the cells. Compared to electrodeposited PdNPs, PdNPs generated by S. oneidensis MR-1 catalyze electrochemically the oxidation...

  10. Shewanella oneidensis MR-1 chemotaxis proteins and electron-transport chain components essential for congregation near insoluble electron acceptors.

    Science.gov (United States)

    Harris, H Wayne; El-Naggar, Mohamed Y; Nealson, Kenneth H

    2012-12-01

    Shewanella oneidensis MR-1 cells utilize a behaviour response called electrokinesis to increase their speed in the vicinity of IEAs (insoluble electron acceptors), including manganese oxides, iron oxides and poised electrodes [Harris, El-Naggar, Bretschger, Ward, Romine, Obraztsova and Nealson (2010) Proc. Natl. Acad. Sci. U.S.A. 107, 326-331]. However, it is not currently understood how bacteria remain in the vicinity of the IEA and accumulate both on the surface and in the surrounding medium. In the present paper, we provide results indicating that cells that have contacted the IEAs swim faster than those that have not recently made contact. In addition, fast-swimming cells exhibit an enhancement of swimming reversals leading to rapid non-random accumulation of cells on, and adjacent to, mineral particles. We call the observed accumulation near IEAs 'congregation'. Congregation is eliminated by the loss of a critical gene involved with EET (extracellular electron transport) (cymA, SO_4591) and is altered or eliminated in several deletion mutants of homologues of genes that are involved with chemotaxis or energy taxis in Escherichia coli. These genes include chemotactic signal transduction protein (cheA-3, SO_3207), methyl-accepting chemotaxis proteins with the Cache domain (mcp_cache, SO_2240) or the PAS (Per/Arnt/Sim) domain (mcp_pas, SO_1385). In the present paper, we report studies of S. oneidensis MR-1 that lend some insight into how microbes in this group can 'sense' the presence of a solid substrate such as a mineral surface, and maintain themselves in the vicinity of the mineral (i.e. via congregation), which may ultimately lead to attachment and biofilm formation.

  11. Crystallization of uridine phosphorylase from Shewanella oneidensis MR-1 in the laboratory and under microgravity and preliminary X-ray diffraction analysis

    International Nuclear Information System (INIS)

    Safonova, Tatyana N.; Mordkovich, Nadezhda N.; Polyakov, Konstantin M.; Manuvera, Valentin A.; Veiko, Vladimir P.; Popov, Vladimir O.

    2012-01-01

    High-quality crystals of uridine phosphorylase from Shewanella oneidensis were grown under microgravity conditions. X-ray diffraction data were collected to a resolution of 0.95 Å. Uridine phosphorylase (UDP, EC 2.4.2.3), a key enzyme in the pyrimidine salvage pathway, catalyses the reversible phosphorolysis of uridine to uracil and ribose 1-phosphate. The gene expression of UDP from Shewanella oneidensis MR-1 was performed in the recipient strain Escherichia coli. The UDP protein was crystallized on earth (in the free form and in complex with uridine as the substrate) by the hanging-drop vapour-diffusion method at 296 K and under microgravity conditions (in the free form) aboard the Russian Segment of the International Space Station by the capillary counter-diffusion method. The data sets were collected to a resolution of 1.9 Å from crystals of the free form grown on earth, 1.6 Å from crystals of the complex with uridine and 0.95 Å from crystals of the free form grown under microgravity. All crystals belong to the space group P2 1 and have similar unit-cell parameters. The crystal of uridine phosphorylase grown under microgravity diffracted to ultra-high resolution and gave high-quality X-ray diffraction data

  12. The role of riboflavin in decolourisation of Congo red and bioelectricity production using Shewanella oneidensis-MR1 under MFC and non-MFC conditions.

    Science.gov (United States)

    Gomaa, Ola M; Fapetu, Segun; Kyazze, Godfrey; Keshavarz, Tajalli

    2017-03-01

    Dissimilatory metal reducing bacteria can exchange electrons extracellularly and hold great promise for their use in simultaneous wastewater treatment and electricity production. This study investigated the role of riboflavin, an electron carrier, in the decolourisation of Congo red in microbial fuel cells (MFCs) using Shewanella oneidensis MR-1 as a model organism. The contribution of the membrane-bound protein MtrC to the decolourisation process was also investigated. Within the range of riboflavin concentrations tested, 20 µM was found to be the best with >95% of the dye (initial concentration 200 mg/L) decolourised in MFCs within 50 h compared to 90% in the case where no riboflavin was added. The corresponding maximum power density was 45 mW/m 2 . There was no significant difference in the overall decolourisation efficiencies of Shewanela oneidensis MR-1 ΔMtrC mutants compared to the wild type. However, in terms of power production the mutant produced more power (P max 76 mW/m 2 ) compared to the wild type (P max 46 mW/m 2 ) which was attributed to higher levels of riboflavin secreted in solution. Decolourisation efficiencies in non-MFC systems (anaerobic bottles) were similar to those under MFC systems indicating that electricity generation in MFCs does not impair dye decolourisation efficiencies. The results suggest that riboflavin enhances both decolourisation of dyes and simultaneous electricity production in MFCs.

  13. Oxygen tension and riboflavin gradients cooperatively regulate the migration of Shewanella oneidensis MR-1 revealed by a hydrogel-based microfluidic device

    Directory of Open Access Journals (Sweden)

    Beum Jun Kim

    2016-09-01

    Full Text Available Shewanella oneidensis (S. oneidensis is a model bacterial strain for studies of bioelectrochemical systems (BESs. It has two extracellular electron transfer pathways: 1 shuttling electrons via an excreted mediator riboflavin; and 2 direct contact between the c-type cytochromes at the cell membrane and the electrode. Despite the extensive use of S. oneidensis in bioelectrochemical systems such as microbial fuel cells and biosensors, many basic microbiology questions about S. oneidensis in the context of BES remain unanswered. Here, we present studies of motility and chemotaxis of S. oneidensis under well controlled concentration gradients of two electron acceptors, oxygen and oxidized form of riboflavin (flavin+ using a newly developed microfluidic platform. Experimental results demonstrate that either oxygen or flavin+ is a chemoattractant to S. oneidensis. The chemotactic tendency of S. oneidensis in a flavin+ concentration gradient is significantly enhanced in an anaerobic in contrast to an aerobic condition. Furthermore, either a low oxygen tension or a high flavin+ concentration considerably enhances the speed of S. oneidensis. This work presents a robust microfluidic platform for generating oxygen and/or flavin+ gradients in an aqueous environment, and demonstrates that two important electron acceptors, oxygen and oxidized riboflavin, cooperatively regulate S. oneidensis migration patterns. The microfluidic tools presented as well as the knowledge gained in this work can be used to guide the future design of BESs for efficient electron production.

  14. Multi-heme Cytochromes in Shewanella oneidensis MR-1: Structures, functions and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Breuer, Marian; Rosso, Kevin M.; Blumberger, Jochen; Butt, Julea N.

    2014-11-05

    Multi-heme cytochromes are employed by a range of microorganisms to transport electrons over distances of up to tens of nanometers. Perhaps the most spectacular utilization of these proteins is in the reduction of extracellular solid substrates, including electrodes and insoluble mineral oxides of Fe(III) and Mn(III/IV), by species of Shewanella and Geobacter. However, multi-heme cytochromes are found in numerous and phylogenetically diverse prokaryotes where they participate in electron transfer and redox catalysis that contributes to biogeochemical cycling of N, S and Fe on the global scale. These properties of multi-heme cytochromes have attracted much interest and contributed to advances in bioenergy applications and bioremediation of contaminated soils. Looking forward there are opportunities to engage multi-heme cytochromes for biological photovoltaic cells, microbial electrosynthesis and developing bespoke molecular devices. As a consequence it is timely to review our present understanding of these proteins and we do this here with a focus on the multitude of functionally diverse multi-heme cytochromes in Shewanella oneidensis MR-1. We draw on findings from experimental and computational approaches which ideally complement each other in the study of these systems: computational methods can interpret experimentally determined properties in terms of molecular structure to cast light on the relation between structure and function. We show how this synergy has contributed to our understanding of multi-heme cytochromes and can be expected to continue to do so for greater insight into natural processes and their informed exploitation in biotechnologies.

  15. Influence of riboflavin on the reduction of radionuclides by Shewanella oneidenis MR-1.

    Science.gov (United States)

    Cherkouk, Andrea; Law, Gareth T W; Rizoulis, Athanasios; Law, Katie; Renshaw, Joanna C; Morris, Katherine; Livens, Francis R; Lloyd, Jonathan R

    2016-03-28

    Uranium (as UO2(2+)), technetium (as TcO4(-)) and neptunium (as NpO2(+)) are highly mobile radionuclides that can be reduced enzymatically by a range of anaerobic and facultatively anaerobic microorganisms, including Shewanella oneidensis MR-1, to poorly soluble species. The redox chemistry of Pu is more complicated, but the dominant oxidation state in most environments is highly insoluble Pu(IV), which can be reduced to Pu(III) which has a potentially increased solubility which could enhance migration of Pu in the environment. Recently it was shown that flavins (riboflavin and flavin mononucleotide (FMN)) secreted by Shewanella oneidensis MR-1 can act as electron shuttles, promoting anoxic growth coupled to the accelerated reduction of poorly-crystalline Fe(III) oxides. Here, we studied the role of riboflavin in mediating the reduction of radionuclides in cultures of Shewanella oneidensis MR-1. Our results demonstrate that the addition of 10 μM riboflavin enhances the reduction rate of Tc(VII) to Tc(IV), Pu(IV) to Pu(III) and to a lesser extent, Np(V) to Np(IV), but has no significant influence on the reduction rate of U(VI) by Shewanella oneidensis MR-1. Thus riboflavin can act as an extracellular electron shuttle to enhance rates of Tc(VII), Np(V) and Pu(IV) reduction, and may therefore play a role in controlling the oxidation state of key redox active actinides and fission products in natural and engineered environments. These results also suggest that the addition of riboflavin could be used to accelerate the bioremediation of radionuclide-contaminated environments.

  16. Mapping the Subcellular Proteome of Shewanella oneidensis MR-1 using Sarkosyl-based fractionation and LC-MS/MS protein identification

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Roslyn N.; Romine, Margaret F.; Schepmoes, Athena A.; Smith, Richard D.; Lipton, Mary S.

    2010-07-19

    A simple and effective subcellular proteomic method for fractionation and analysis of gram-negative bacterial cytoplasm, periplasm, inner, and outer membranes was applied to Shewanella oneidensis to gain insight into its subcellular architecture. A combination of differential centrifugation, Sarkosyl solubilization, and osmotic lysis was used to prepare subcellular fractions. Global differences in protein fractions were observed by SDS PAGE and heme staining, and tryptic peptides were analyzed using high-resolution LC-MS/MS. Compared to crude cell lysates, the fractionation method achieved a significant enrichment (average ~2-fold) in proteins predicted to be localized to each subcellular fraction. Compared to other detergent, organic solvent, and density-based methods previously reported, Sarkosyl most effectively facilitated separation of the inner and outer membranes and was amenable to mass spectrometry, making this procedure ideal for probing the subcellular proteome of gram-negative bacteria via LC-MS/MS. With 40% of the observable proteome represented, this study has provided extensive information on both subcellular architecture and relative abundance of proteins in S. oneidensis and provides a foundation for future work on subcellular organization and protein-membrane interactions in other gram-negative bacteria.

  17. WO3 nanorods-modified carbon electrode for sustained electron uptake from Shewanella oneidensis MR-1 with suppressed biofilm formation

    International Nuclear Information System (INIS)

    Zhang, Feng; Yuan, Shi-Jie; Li, Wen-Wei; Chen, Jie-Jie; Ko, Chi-Chiu; Yu, Han-Qing

    2015-01-01

    Highlights: • WO 3 nanorods-modified carbon paper was used as the anode of MFC. • WO 3 nanorods suppressed biofilm growth on the electrode surface. • Sustained electron transfer from cells to electrode via riboflavin was achieved. • C–WO 3 nanorods enable stable and efficient EET process in long-time operation. - Abstract: Carbon materials are widely used as electrodes for bioelectrochemical systems (BES). However, a thick biofilm tends to grow on the electrode surface during continuous operation, resulting in constrained transport of electrons and nutrients at the cell-electrode interface. In this work, we tackled this problem by adopting a WO 3 -nanorods modified carbon electrode (C–WO 3 nanorods), which completely suppressed the biofilm growth of Shewanella Oneidensis MR-1. Moreover, the C–WO 3 nanorods exhibited high electric conductivity and strong response to riboflavin. These two factors together make it possible for the C–WO 3 nanorods to maintain a sustained, efficient process of electron transfer from the MR-1 planktonic cells. As a consequence, the microbial fuel cells with C–WO 3 nanorods anode showed more stable performance than the pure carbon paper and WO 3 -nanoparticles systems in prolonged operation. This work suggests that WO 3 nanorods have the potential to be used as a robust and biofouling-resistant electrode material for practical bioelectrochemical applications

  18. Flavin as an Indicator of the Rate-Limiting Factor for Microbial Current Production in Shewanella oneidensis MR-1

    International Nuclear Information System (INIS)

    Saito, Junki; Hashimoto, Kazuhito; Okamoto, Akihiro

    2016-01-01

    Microbial electrode catalysis such as microbial fuel cells or electrosynthesis involves electron exchange with the electrodes located at the cell exterior; i.e., extracellular electron transport (EET). Despite the vast amount of research on the kinetics of EET to optimize the catalysis rate, the relevance of other factors, including upstream metabolic reactions, has scarcely been investigated. Herein, we report an in vivo electrochemical assay to confirm whether EET limits anodic current production (j) for the lactate oxidation of Shewanella oneidensis MR-1. Addition of riboflavin, which specifically enhances the EET rate, increased j only in the early phase before j saturation. In contrast, when we removed a trace metal ion necessary for upstream reactions from the electrolyte, a significant decrease in j and the lactate consumption rate was observed only after j saturation. These data suggest that the limiting factor for j shifted from EET to upstream reactions, highlighting the general importance of enhancing, for example, microbial metabolism, especially for long-standing practical applications. Our concept to specifically control the rate of EET could be applicable to other bioelectrode catalysis systems as a strategy to monitor their rate-limiting factors.

  19. Global transcriptome analysis of the heat shock response ofshewanella oneidensis

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Haichun; Wang, Sarah; Liu, Xueduan; Yan, Tinfeng; Wu, Liyou; Alm, Eric; Arkin, Adam P.; Thompson, Dorothea K.; Zhou, Jizhong

    2004-04-30

    Shewanella oneidensis is an important model organism for bioremediation studies because of its diverse respiratory capabilities. However, the genetic basis and regulatory mechanisms underlying the ability of S. oneidensis to survive and adapt to various environmentally relevant stresses is poorly understood. To define this organism's molecular response to elevated growth temperatures, temporal gene expression profiles were examined in cells subjected to heat stress using whole-genome DNA microarrays for S. oneidensis MR-1. Approximately 15 percent (711) of the predicted S. oneidensis genes represented on the microarray were significantly up- or down-regulated (P < 0.05) over a 25-min period following shift to the heat shock temperature (42 C). As expected, the majority of S. oneidensis genes exhibiting homology to known chaperones and heat shock proteins (Hsps) were highly and transiently induced. In addition, a number of predicted genes encoding enzymes in glycolys is and the pentose cycle, [NiFe] dehydrogenase, serine proteases, transcriptional regulators (MerR, LysR, and TetR families), histidine kinases, and hypothetical proteins were induced in response to heat stress. Genes encoding membrane proteins were differentially expressed, suggesting that cells possibly alter their membrane composition or structure in response to variations in growth temperature. A substantial number of the genes encoding ribosomal proteins displayed down-regulated co-expression patterns in response to heat stress, as did genes encoding prophage and flagellar proteins. Finally, based on computational comparative analysis of the upstream promoter regions of S.oneidensis heat-inducible genes, a putative regulatory motif, showing high conservation to the Escherichia coli sigma 32-binding consensus sequence, was identified.

  20. The outer membrane protein Omp35 affects the reduction of Fe(III, nitrate, and fumarate by Shewanella oneidensis MR-1

    Directory of Open Access Journals (Sweden)

    Myers Charles R

    2004-06-01

    Full Text Available Abstract Background Shewanella oneidensis MR-1 uses several electron acceptors to support anaerobic respiration including insoluble species such as iron(III and manganese(IV oxides, and soluble species such as nitrate, fumarate, dimethylsulfoxide and many others. MR-1 has complex branched electron transport chains that include components in the cytoplasmic membrane, periplasm, and outer membrane (OM. Previous studies have implicated a role for anaerobically upregulated OM electron transport components in the use of insoluble electron acceptors, and have suggested that other OM components may also contribute to insoluble electron acceptor use. In this study, the role for an anaerobically upregulated 35-kDa OM protein (Omp35 in the use of anaerobic electron acceptors was explored. Results Omp35 was purified from the OM of anaerobically grown cells, the gene encoding Omp35 was identified, and an omp35 null mutant (OMP35-1 was isolated and characterized. Although OMP35-1 grew on all electron acceptors tested, a significant lag was seen when grown on fumarate, nitrate, and Fe(III. Complementation studies confirmed that the phenotype of OMP35-1 was due to the loss of Omp35. Despite its requirement for wild-type rates of electron acceptor use, analysis of Omp35 protein and predicted sequence did not identify any electron transport moieties or predicted motifs. OMP35-1 had normal levels and distribution of known electron transport components including quinones, cytochromes, and fumarate reductase. Omp35 is related to putative porins from MR-1 and S. frigidimarina as well as to the PorA porin from Neisseria meningitidis. Subcellular fraction analysis confirmed that Omp35 is an OM protein. The seven-fold anaerobic upregulation of Omp35 is mediated post-transcriptionally. Conclusion Omp35 is a putative porin in the OM of MR-1 that is markedly upregulated anaerobically by a post-transcriptional mechanism. Omp35 is required for normal rates of growth on Fe

  1. Integrated genome based studies of Shewanella ecophysiology

    Energy Technology Data Exchange (ETDEWEB)

    Saffarini, Daad A

    2013-03-07

    Progress is reported in these areas: Regulation of anaerobic respiration by cAMP receptor protein and role of adenylate cyclases; Identification of an octaheme c cytochrome as the terminal sulfite reductase in S. oneidensis MR-1; Identification and analysis of components of the electron transport chains that lead to reduction of thiosulfate, tetrathionate, and elemental sulfur in MR-1; Involvement of pili and flagella in metal reduction by S. oneidensis MR-1; and work suggesting that HemN1 is the major enzyme that is involved in heme biosynthesis under anaerobic conditions.

  2. Genome-scale metabolic network validation of Shewanella oneidensis using transposon insertion frequency analysis.

    Directory of Open Access Journals (Sweden)

    Hong Yang

    2014-09-01

    Full Text Available Transposon mutagenesis, in combination with parallel sequencing, is becoming a powerful tool for en-masse mutant analysis. A probability generating function was used to explain observed miniHimar transposon insertion patterns, and gene essentiality calls were made by transposon insertion frequency analysis (TIFA. TIFA incorporated the observed genome and sequence motif bias of the miniHimar transposon. The gene essentiality calls were compared to: 1 previous genome-wide direct gene-essentiality assignments; and, 2 flux balance analysis (FBA predictions from an existing genome-scale metabolic model of Shewanella oneidensis MR-1. A three-way comparison between FBA, TIFA, and the direct essentiality calls was made to validate the TIFA approach. The refinement in the interpretation of observed transposon insertions demonstrated that genes without insertions are not necessarily essential, and that genes that contain insertions are not always nonessential. The TIFA calls were in reasonable agreement with direct essentiality calls for S. oneidensis, but agreed more closely with E. coli essentiality calls for orthologs. The TIFA gene essentiality calls were in good agreement with the MR-1 FBA essentiality predictions, and the agreement between TIFA and FBA predictions was substantially better than between the FBA and the direct gene essentiality predictions.

  3. Reduced heme levels underlie the exponential growth defect of the Shewanella oneidensis hfq mutant.

    Directory of Open Access Journals (Sweden)

    Christopher M Brennan

    Full Text Available The RNA chaperone Hfq fulfills important roles in small regulatory RNA (sRNA function in many bacteria. Loss of Hfq in the dissimilatory metal reducing bacterium Shewanella oneidensis strain MR-1 results in slow exponential phase growth and a reduced terminal cell density at stationary phase. We have found that the exponential phase growth defect of the hfq mutant in LB is the result of reduced heme levels. Both heme levels and exponential phase growth of the hfq mutant can be completely restored by supplementing LB medium with 5-aminolevulinic acid (5-ALA, the first committed intermediate synthesized during heme synthesis. Increasing expression of gtrA, which encodes the enzyme that catalyzes the first step in heme biosynthesis, also restores heme levels and exponential phase growth of the hfq mutant. Taken together, our data indicate that reduced heme levels are responsible for the exponential growth defect of the S. oneidensis hfq mutant in LB medium and suggest that the S. oneidensis hfq mutant is deficient in heme production at the 5-ALA synthesis step.

  4. Programming the quorum sensing-based AND gate in Shewanella oneidensis for logic gated-microbial fuel cells.

    Science.gov (United States)

    Hu, Yidan; Yang, Yun; Katz, Evgeny; Song, Hao

    2015-03-11

    An AND logic gate based on a synthetic quorum-sensing (QS) module was constructed in a Shewanella oneidensis MR-1 mtrA knockout mutant. The presence of two input signals activated the expression of a periplasmic decaheme cytochrome MtrA to regenerate the extracellular electron transfer conduit, enabling the construction of AND-gated microbial fuel cells.

  5. Characterization of the periplasmic redox network that sustains the versatile anaerobic metabolism of Shewanella oneidensis MR-1

    Directory of Open Access Journals (Sweden)

    Mónica N. Alves

    2015-06-01

    Full Text Available The versatile anaerobic metabolism of the Gram-negative bacterium Shewanella oneidensis MR-1 (SOMR-1 relies on a multitude of redox proteins found in its periplasm. Most are multiheme cytochromes that carry electrons to terminal reductases of insoluble electron acceptors located at the cell surface, or bona fide terminal reductases of soluble electron acceptors. In this study, the interaction network of several multiheme cytochromes was explored by a combination of NMR spectroscopy, activity assays followed by UV-visible spectroscopy and comparison of surface electrostatic potentials. From these data the small tetraheme cytochrome (STC emerges as the main periplasmic redox shuttle in SOMR-1. It accepts electrons from CymA and distributes them to a number of terminal oxidoreductases involved in the respiration of various compounds. STC is also involved in the electron transfer pathway to reduce nitrite by interaction with the octaheme tetrathionate reductase (OTR, but not with cytochrome c nitrite reductase (ccNiR. In the main pathway leading the metal respiration STC pairs with flavocytochrome c (FccA, the other major periplasmic cytochrome, which provides redundancy in this important pathway. The data reveals that the two proteins compete for the binding site at the surface of MtrA, the decaheme cytochrome inserted on the periplasmic side of the MtrCAB-OmcA outer-membrane complex. However, this is not observed for the MtrA homologues. Indeed, neither STC nor FccA interact with MtrD, the best replacement for MtrA, and only STC is able to interact with the decaheme cytochrome DmsE of the outer-membrane complex DmsEFABGH. Overall, these results shown that STC plays a central role in the anaerobic respiratory metabolism of SOMR-1. Nonetheless, the trans-periplasmic electron transfer chain is functionally resilient as a consequence of redundancies that arise from the presence of alternative pathways that bypass/compete with STC.

  6. Use of an Electrochemical Split Cell Technique to Evaluate the Influence of Shewanella oneidensis Activities on Corrosion of Carbon Steel.

    Directory of Open Access Journals (Sweden)

    Robert Bertram Miller

    Full Text Available Microbially induced corrosion (MIC is a complex problem that affects various industries. Several techniques have been developed to monitor corrosion and elucidate corrosion mechanisms, including microbiological processes that induce metal deterioration. We used zero resistance ammetry (ZRA in a split chamber configuration to evaluate the effects of the facultatively anaerobic Fe(III reducing bacterium Shewanella oneidensis MR-1 on the corrosion of UNS G10180 carbon steel. We show that activities of S. oneidensis inhibit corrosion of steel with which that organism has direct contact. However, when a carbon steel coupon in contact with S. oneidensis was electrically connected to a second coupon that was free of biofilm (in separate chambers of the split chamber assembly, ZRA-based measurements indicated that current moved from the S. oneidensis-containing chamber to the cell-free chamber. This electron transfer enhanced the O2 reduction reaction on the coupon deployed in the cell free chamber, and consequently, enhanced oxidation and corrosion of that electrode. Our results illustrate a novel mechanism for MIC in cases where metal surfaces are heterogeneously covered by biofilms.

  7. Iron triggers λSo prophage induction and release of extracellular DNA in Shewanella oneidensis MR-1 biofilms.

    Science.gov (United States)

    Binnenkade, Lucas; Teichmann, Laura; Thormann, Kai M

    2014-09-01

    Prophages are ubiquitous elements within bacterial chromosomes and affect host physiology and ecology in multiple ways. We have previously demonstrated that phage-induced lysis is required for extracellular DNA (eDNA) release and normal biofilm formation in Shewanella oneidensis MR-1. Here, we investigated the regulatory mechanisms of prophage λSo spatiotemporal induction in biofilms. To this end, we used a functional fluorescence fusion to monitor λSo activation in various mutant backgrounds and in response to different physiological conditions. λSo induction occurred mainly in a subpopulation of filamentous cells in a strictly RecA-dependent manner, implicating oxidative stress-induced DNA damage as the major trigger. Accordingly, mutants affected in the oxidative stress response (ΔoxyR) or iron homeostasis (Δfur) displayed drastically increased levels of phage induction and abnormal biofilm formation, while planktonic cells were not or only marginally affected. To further investigate the role of oxidative stress, we performed a mutant screen and identified two independent amino acid substitutions in OxyR (T104N and L197P) that suppress induction of λSo by hydrogen peroxide (H2O2). However, λSo induction was not suppressed in biofilms formed by both mutants, suggesting a minor role of intracellular H2O2 in this process. In contrast, addition of iron to biofilms strongly enhanced λSo induction and eDNA release, while both processes were significantly suppressed at low iron levels, strongly indicating that iron is the limiting factor. We conclude that uptake of iron during biofilm formation triggers λSo-mediated lysis of a subpopulation of cells, likely by an increase in iron-mediated DNA damage sensed by RecA. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  8. In Vitro Enzymatic Reduction Kinetics of Mineral Oxides by Membrane Fractions from Shewanella oneidensis MR-1

    International Nuclear Information System (INIS)

    Ruebush, S.; Icopini, G.; Brantley, S.; Tien, M.

    2006-01-01

    This study documents the first example of in vitro solid-phase mineral oxide reduction by enzyme-containing membrane fractions. Previous in vitro studies have only reported the reduction of aqueous ions. Total membrane (TM) fractions from iron-grown cultures of Shewanella oneidensis MR-1 were isolated and shown to catalyze the reduction of goethite, hematite, birnessite, and ramsdellite/pyrolusite using formate. In contrast, nicotinamide adenine dinucleotide (NADH) and succinate cannot function as electron donors. The significant implications of observations related to this cell-free system are: (i) both iron and manganese mineral oxides are reduced by the TM fraction, but aqueous U(VI) is not; (ii) TM fractions from anaerobically grown, but not aerobically grown, cells can reduce the mineral oxides; (iii) electron shuttles and iron chelators are not needed for this in vitro reduction, documenting conclusively that reduction can occur by direct contact with the mineral oxide; (iv) electron shuttles and EDTA stimulate the in vitro Fe(III) reduction, documenting that exogenous molecules can enhance rates of enzymatic mineral reduction; and (v) multiple membrane components are involved in solid-phase oxide reduction. The membrane fractions, consisting of liposomes of cytoplasmic and outer membrane segments, contain at least 100 proteins including the enzyme that oxidizes formate, formate dehydrogenase. Mineral oxide reduction was inhibited by the addition of detergent Triton X-100, which solubilizes membranes and their associated proteins, consistent with the involvement of multiple electron carriers that are disrupted by detergent addition. In contrast, formate dehydrogenase activity was not inhibited by Triton X-100. The addition of anthraquinone-2,6-disulfonate (AQDS) and menaquinone-4 was unable to restore activity; however, menadione (MD) restored 33% of the activity. The addition of AQDS and MD to reactions without added detergent increased the rate of goethite

  9. Modeling Substrate Utilization, Metabolite Production, and Uranium Immobilization in Shewanella oneidensis Biofilms

    Directory of Open Access Journals (Sweden)

    Ryan S. Renslow

    2017-06-01

    Full Text Available In this study, we developed a two-dimensional mathematical model to predict substrate utilization and metabolite production rates in Shewanella oneidensis MR-1 biofilm in the presence and absence of uranium (U. In our model, lactate and fumarate are used as the electron donor and the electron acceptor, respectively. The model includes the production of extracellular polymeric substances (EPS. The EPS bound to the cell surface and distributed in the biofilm were considered bound EPS (bEPS and loosely associated EPS (laEPS, respectively. COMSOL® Multiphysics finite element analysis software was used to solve the model numerically (model file provided in the Supplementary Material. The input variables of the model were the lactate, fumarate, cell, and EPS concentrations, half saturation constant for fumarate, and diffusion coefficients of the substrates and metabolites. To estimate unknown parameters and calibrate the model, we used a custom designed biofilm reactor placed inside a nuclear magnetic resonance (NMR microimaging and spectroscopy system and measured substrate utilization and metabolite production rates. From these data we estimated the yield coefficients, maximum substrate utilization rate, half saturation constant for lactate, stoichiometric ratio of fumarate and acetate to lactate and stoichiometric ratio of succinate to fumarate. These parameters are critical to predicting the activity of biofilms and are not available in the literature. Lastly, the model was used to predict uranium immobilization in S. oneidensis MR-1 biofilms by considering reduction and adsorption processes in the cells and in the EPS. We found that the majority of immobilization was due to cells, and that EPS was less efficient at immobilizing U. Furthermore, most of the immobilization occurred within the top 10 μm of the biofilm. To the best of our knowledge, this research is one of the first biofilm immobilization mathematical models based on experimental

  10. Unique organizational and functional features of the cytochrome c maturation system in Shewanella oneidensis.

    Directory of Open Access Journals (Sweden)

    Miao Jin

    Full Text Available Shewanella are renowned for their ability to respire on a wide range of electron acceptors, which has been partially accredited to the presence of a large number of the c-type cytochromes. In the model species S. oneidensis MR-1, at least 41 genes encode c-type cytochromes that are predicted to be intact, thereby likely functional. Previously, in-frame deletion mutants for 36 of these genes were obtained and characterized. In this study, first we completed the construction of an entire set of c-type cytochrome mutants utilizing a newly developed att-based mutagenesis approach, which is more effective and efficient than the approach used previously by circumventing the conventional cloning. Second, we investigated the cytochrome c maturation (Ccm system in S. oneidensis. There are two loci predicted to encode components of the Ccm system, SO0259-SO0269 and SO0476-SO0478. The former is proven essential for cytochrome c maturation whereas the latter is dispensable. Unlike the single operon organization observed in other γ-proteobacteria, genes at the SO0259-SO0269 locus are uniquely organized into four operons, ccmABCDE, scyA, SO0265, and ccmFGH-SO0269. Functional analysis revealed that the SO0265 gene rather than the scyA and SO0269 genes are relevant to cytochrome c maturation.

  11. Functional Analysis of Shewanella, a cross genome comparison.

    Energy Technology Data Exchange (ETDEWEB)

    Serres, Margrethe H.

    2009-05-15

    The bacterial genus Shewanella includes a group of highly versatile organisms that have successfully adapted to life in many environments ranging from aquatic (fresh and marine) to sedimentary (lake and marine sediments, subsurface sediments, sea vent). A unique respiratory capability of the Shewanellas, initially observed for Shewanella oneidensis MR-1, is the ability to use metals and metalloids, including radioactive compounds, as electron acceptors. Members of the Shewanella genus have also been shown to degrade environmental pollutants i.e. halogenated compounds, making this group highly applicable for the DOE mission. S. oneidensis MR-1 has in addition been found to utilize a diverse set of nutrients and to have a large set of genes dedicated to regulation and to sensing of the environment. The sequencing of the S. oneidensis MR-1 genome facilitated experimental and bioinformatics analyses by a group of collaborating researchers, the Shewanella Federation. Through the joint effort and with support from Department of Energy S. oneidensis MR-1 has become a model organism of study. Our work has been a functional analysis of S. oneidensis MR-1, both by itself and as part of a comparative study. We have improved the annotation of gene products, assigned metabolic functions, and analyzed protein families present in S. oneidensis MR-1. The data has been applied to analysis of experimental data (i.e. gene expression, proteome) generated for S. oneidensis MR-1. Further, this work has formed the basis for a comparative study of over 20 members of the Shewanella genus. The species and strains selected for genome sequencing represented an evolutionary gradient of DNA relatedness, ranging from close to intermediate, and to distant. The organisms selected have also adapted to a variety of ecological niches. Through our work we have been able to detect and interpret genome similarities and differences between members of the genus. We have in this way contributed to the

  12. Hsp90 Is Essential under Heat Stress in the Bacterium Shewanella oneidensis

    Directory of Open Access Journals (Sweden)

    Flora Ambre Honoré

    2017-04-01

    Full Text Available The Hsp90 chaperone is essential in eukaryotes and activates a large array of client proteins. In contrast, its role is still elusive in bacteria, and only a few Hsp90 bacterial clients are known. Here, we found that Hsp90 is essential in the model bacterium Shewanella oneidensis under heat stress. A genetic screen for Hsp90 client proteins identified TilS, an essential protein involved in tRNA maturation. Overexpression of TilS rescued the growth defect of the hsp90 deletion strain under heat stress. In vivo, the activity and the amount of TilS were significantly reduced in the absence of Hsp90 at high temperature. Furthermore, we showed that Hsp90 interacts with TilS, and Hsp90 prevents TilS aggregation in vitro at high temperature. Together, our results indicate that TilS is a client of Hsp90 in S. oneidensis. Therefore, our study links the essentiality of bacterial Hsp90 at high temperature with the identification of a client.

  13. Global Molecular and Morphological Effects of 24-Hour Chromium(VI)Exposure on Shewanella oneidensis MR-1

    Energy Technology Data Exchange (ETDEWEB)

    Chourey, Karuna [ORNL; Thompson, Melissa R [ORNL; Morrell-Falvey, Jennifer L [ORNL; Verberkmoes, Nathan C [ORNL; Brown, Steven D [ORNL; Shah, Manesh B [ORNL; Zhou, Jizhong [ORNL; Doktycz, Mitchel John [ORNL; Hettich, Robert {Bob} L [ORNL; Thompson, Dorothea K [ORNL

    2006-01-01

    The biological impact of 24-h ("chronic") chromium(VI) [Cr(VI) or chromate] exposure on ShewanellaoneidensisMR-1 was assessed by analyzing cellular morphology as well as genome-wide differential gene and protein expression profiles. Cells challenged aerobically with an initial chromate concentration of 0.3 mM in complex growth medium were compared to untreated control cells grown in the absence of chromate. At the 24-h time point at which cells were harvested for transcriptome and proteome analyses, no residual Cr(VI) was detected in the culture supernatant, thus suggesting the complete uptake and/or reduction of this metal by cells. In contrast to the untreated control cells, Cr(VI)-exposed cells formed apparently aseptate, nonmotile filaments that tended to aggregate. Transcriptome profiling and mass spectrometry-based proteomic charac terization revealed that the principal molecular response to 24-h Cr(VI) exposure was the induction of prophage-related genes and their encoded products as well as a number of functionally undefined hypothetical genes that were located within the integrated phage regions of the MR-1 genome. In addition, genes with annotated functions in DNA metabolism, cell division, biosynthesis and degradation of the murein (pepti doglycan) sacculus, membrane response, and general environmental stress protection were upregulated, while genes encoding chemotaxis, motility, and transport/binding proteins were largely repressed under conditions of 24-h chromate treatment.

  14. Evolution of Cell Size Homeostasis and Growth Rate Diversity during Initial Surface Colonization of Shewanella oneidensis.

    Science.gov (United States)

    Lee, Calvin K; Kim, Alexander J; Santos, Giancarlo S; Lai, Peter Y; Lee, Stella Y; Qiao, David F; Anda, Jaime De; Young, Thomas D; Chen, Yujie; Rowe, Annette R; Nealson, Kenneth H; Weiss, Paul S; Wong, Gerard C L

    2016-09-06

    Cell size control and homeostasis are fundamental features of bacterial metabolism. Recent work suggests that cells add a constant size between birth and division ("adder" model). However, it is not known how cell size homeostasis is influenced by the existence of heterogeneous microenvironments, such as those during biofilm formation. Shewanella oneidensis MR-1 can use diverse energy sources on a range of surfaces via extracellular electron transport (EET), which can impact growth, metabolism, and size diversity. Here, we track bacterial surface communities at single-cell resolution to show that not only do bacterial motility appendages influence the transition from two- to three-dimensional biofilm growth and control postdivisional cell fates, they strongly impact cell size homeostasis. For every generation, we find that the average growth rate for cells that stay on the surface and continue to divide (nondetaching population) and that for cells that detach before their next division (detaching population) are roughly constant. However, the growth rate distribution is narrow for the nondetaching population, but broad for the detaching population in each generation. Interestingly, the appendage deletion mutants (ΔpilA, ΔmshA-D, Δflg) have significantly broader growth rate distributions than that of the wild type for both detaching and nondetaching populations, which suggests that Shewanella appendages are important for sensing and integrating environmental inputs that contribute to size homeostasis. Moreover, our results suggest multiplexing of appendages for sensing and motility functions contributes to cell size dysregulation. These results can potentially provide a framework for generating metabolic diversity in S. oneidensis populations to optimize EET in heterogeneous environments.

  15. Molecular underpinnings of nitrite effect on CymA-dependent respiration in Shewanella oneidensis

    Directory of Open Access Journals (Sweden)

    Miao Jin

    2016-07-01

    Full Text Available Shewanella exhibit a remarkable versatility of respiration, with a diverse array of electron acceptors (EAs. In environments where these bacteria thrive, multiple EAs are usually present. However, we know little about strategies by which these EAs and their interaction affect ecophysiology of Shewanella. In this study, we demonstrate in the model strain, Shewanella oneidensis MR-1, that nitrite, not through nitric oxide to which it may convert, inhibits respiration of fumarate, and probably many other EAs whose reduction depends on quinol dehydrogenase CymA. This is achieved via the repression of cyclic adenosine monophosphate (cAMP production, a second messenger required for activation of cAMP-receptor protein (Crp which plays a primary role in regulation of respiration. If nitrite is not promptly removed, intracellular cAMP levels drop, and this impairs Crp activity. As a result, the production of nitrite reductase NrfA, CymA, and fumarate reductase FccA is substantially reduced. In contrast, nitrite can be simultaneously respired with trimethylamine N-oxide, resulting in enhanced biomass.

  16. Functional assessment of EnvZ/OmpR two-component system in Shewanella oneidensis.

    Directory of Open Access Journals (Sweden)

    Jie Yuan

    Full Text Available EnvZ and OmpR constitute the bacterial two-component signal transduction system known to mediate osmotic stress response in a number of gram-negative bacteria. In an effort to understand the mechanism through which Shewanella oneidensis senses and responds to environmental osmolarity changes, structure of the ompR-envZ operon was determined with Northern blotting assay and roles of the EnvZ/OmpR two-component system in response to various stresses were investigated with mutational analysis, quantitative reverse transcriptase PCR (qRT-PCR, and phenotype microarrays. Results from the mutational analysis and qRT-PCR suggested that the EnvZ/OmpR system contributed to osmotic stress response of S. oneidensis and very likely engaged a similar strategy employed by E. coli, which involved reciprocal regulation of two major porin coding genes. Additionally, the ompR-envZ system was also found related to cell motility. We further showed that the ompR-envZ dependent regulation of porin genes and motility resided almost completely on ompR and only partially on envZ, indicating additional mechanisms for OmpR phosphorylation. In contrast to E. coli lacking ompR-envZ, however, growth of S. oneidensis did not show a significant dependence on ompR-envZ even under osmotic stress. Further analysis with phenotype microarrays revealed that the S. oneidensis strains lacking a complete ompR-envZ system displayed hypersensitivities to a number of agents, especially in alkaline environment. Taken together, our results suggest that the function of the ompR-envZ system in S. oneidensis, although still connected with osmoregulation, has diverged considerably from that of E. coli. Additional mechanism must exist to support growth of S. oneidensis under osmotic stress.

  17. Synthetic Klebsiella pneumoniae-Shewanella oneidensis Consortium Enables Glycerol-Fed High-Performance Microbial Fuel Cells.

    Science.gov (United States)

    Li, Feng; Yin, Changji; Sun, Liming; Li, Yuanxiu; Guo, Xuewu; Song, Hao

    2018-05-01

    Microbial fuel cell (MFC) is an eco-friendly bio-electrochemical sys-tem that uses microorganism as biocatalyst to convert biomass into electricity. Glycerol, as a waste in the biodiesel refinery processes, is an appealing substrate for MFC. Nevertheless, glycerol cannot be utilized as carbon source by well-known exoelectrogens such as Shewanella oneidensis. Herein, to generate electricity by rapidly harnessing glycerol, the authors rationally constructed a Klebsiella pneumoniae-Shewanella oneidensis microbial consortium to efficiently harvest electricity from glyc-erol, in which K. pneumoniae converted glycerol into lactate, fed to S. oneidensis as carbon source and electron donor. To improve electricity output, the authors systematically engineered the consortium in terms of carbon flux distribution and efficiency of extracellular electron transfer (EET). To direct more carbon flux to lactate biosynthesis in K. pneumoniae, the authors eliminated the ethanol pathway by knocking out the alcohol dehydrogenase gene (adhE), and enhanced lactate biosynthesis by heterologously expressing a lactate dehydrogen-ase gene (ldhD) from Lactobacillus bulgaricus and a lactate transporter gene (lldP) from Escherichia coli. To facilitate EET between S. oneidensis and anode surfaces, a biosynthetic flavins pathway from Bacillus subtilis is introduced into S. oneidensis. The author further optimized the glycerol concentration, thus S. oneidensis could be continuously fed with lactate synthesized from K. pneumoniae at a constant rate. Our glycerol-fed MFC generated a maximum power density of 19.9 mW/m 2 , significantly higher than that of the wild-type consor-tium. This work suggested that engineering microbial consortia is an effi-cient strategy to expand the spectrum of usable carbon sources and promote electricity power production in MFCs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Craniopharyngioma identification by CT and MR imaging at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Hald, J.K. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Eldevik, O.P. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States); Skalpe, I.O. [Dept. of Radiology, Rikshospitalet, Oslo Univ. (Norway)]|[Dept. of Radiology, Univ. of Michigan Hospitals, Ann Arbor, MI (United States)

    1995-03-01

    To compare the detectability of craniopharyngiomas by CT and MR imaging, preoperative CT and MR studies obtained within 16 days of each other were evaluated retrospectively in 9 patients. MR imaging demonstrated cystic and solid tumor components in all 9 tumors, and enhancement in the 7 tumors that were studied after contrast medium injection. MR imaging demonstrated a signal void consistent with calcification in 4 patients. Combining unenhanced and contrast medium-enhanced studies, CT also identified all the tumors. CT demonstrated cysts in 7 lesions, calcification in 7 and enhancement in 6 of the 7 lesions that received i.v. contrast medium. Calcification was better seen by CT than MR imaging, while MR imaging identified cystic tumor components not seen on CT. The contrast medium enhancement pattern was the same with the 2 modalities. MR imaging of the sellar region, including at least one contrast medium-enhanced sequence, should be sufficient in most instances to establish a preoperative diagnosis of craniopharyngioma. (orig.).

  19. c-Type cytochrome-dependent formation of U(IV nanoparticles by Shewanella oneidensis.

    Directory of Open Access Journals (Sweden)

    Matthew J Marshall

    2006-09-01

    Full Text Available Modern approaches for bioremediation of radionuclide contaminated environments are based on the ability of microorganisms to effectively catalyze changes in the oxidation states of metals that in turn influence their solubility. Although microbial metal reduction has been identified as an effective means for immobilizing highly-soluble uranium(VI complexes in situ, the biomolecular mechanisms of U(VI reduction are not well understood. Here, we show that c-type cytochromes of a dissimilatory metal-reducing bacterium, Shewanella oneidensis MR-1, are essential for the reduction of U(VI and formation of extracellular UO(2 nanoparticles. In particular, the outer membrane (OM decaheme cytochrome MtrC (metal reduction, previously implicated in Mn(IV and Fe(III reduction, directly transferred electrons to U(VI. Additionally, deletions of mtrC and/or omcA significantly affected the in vivo U(VI reduction rate relative to wild-type MR-1. Similar to the wild-type, the mutants accumulated UO(2 nanoparticles extracellularly to high densities in association with an extracellular polymeric substance (EPS. In wild-type cells, this UO(2-EPS matrix exhibited glycocalyx-like properties and contained multiple elements of the OM, polysaccharide, and heme-containing proteins. Using a novel combination of methods including synchrotron-based X-ray fluorescence microscopy and high-resolution immune-electron microscopy, we demonstrate a close association of the extracellular UO(2 nanoparticles with MtrC and OmcA (outer membrane cytochrome. This is the first study to our knowledge to directly localize the OM-associated cytochromes with EPS, which contains biogenic UO(2 nanoparticles. In the environment, such association of UO(2 nanoparticles with biopolymers may exert a strong influence on subsequent behavior including susceptibility to oxidation by O(2 or transport in soils and sediments.

  20. Electrocatalytic oxidation of K4[Fe(CN)6] by metal-reducing bacteriumShewanella oneidensis MR-1

    DEFF Research Database (Denmark)

    Zheng, Zhiyong; Xiao, Yong; Wu, Ranran

    2017-01-01

    of an inorganic redox compound K4[Fe(CN)6]. A pair of symmetric peak in the cyclic voltammetry (CV) of K4[Fe(CN)6] were found on bare glassy carbon electrode (GCE). Surprisingly, when the GCE is coated MR-1, the anodic peak almost sustained at the same level; while the cathodic peak apparently shrunk. We...

  1. Microfabricated microbial fuel cell arrays reveal electrochemically active microbes.

    Directory of Open Access Journals (Sweden)

    Huijie Hou

    Full Text Available Microbial fuel cells (MFCs are remarkable "green energy" devices that exploit microbes to generate electricity from organic compounds. MFC devices currently being used and studied do not generate sufficient power to support widespread and cost-effective applications. Hence, research has focused on strategies to enhance the power output of the MFC devices, including exploring more electrochemically active microbes to expand the few already known electricigen families. However, most of the MFC devices are not compatible with high throughput screening for finding microbes with higher electricity generation capabilities. Here, we describe the development of a microfabricated MFC array, a compact and user-friendly platform for the identification and characterization of electrochemically active microbes. The MFC array consists of 24 integrated anode and cathode chambers, which function as 24 independent miniature MFCs and support direct and parallel comparisons of microbial electrochemical activities. The electricity generation profiles of spatially distinct MFC chambers on the array loaded with Shewanella oneidensis MR-1 differed by less than 8%. A screen of environmental microbes using the array identified an isolate that was related to Shewanella putrefaciens IR-1 and Shewanella sp. MR-7, and displayed 2.3-fold higher power output than the S. oneidensis MR-1 reference strain. Therefore, the utility of the MFC array was demonstrated.

  2. Regulation of biofilm formation in Shewanella oneidensis by BpfA, BpfG, and BpfD

    Directory of Open Access Journals (Sweden)

    Guangqi eZhou

    2015-08-01

    Full Text Available Bacteria switch between two distinct life styles -- planktonic (free living and biofilm forming -- in keeping with their ever-changing environment. Such switch involves sophisticated signaling and tight regulation, which provides a fascinating portal for studying gene function and orchestrated protein interactions. In this work, we investigated the molecular mechanism underlying biofilm formation in S. oneidensis MR-1, an environmentally important model bacterium renowned for respiratory diversities, and uncovered a gene cluster coding for seven proteins involved in this process. The three key proteins, BpfA, BpfG, and BpfD, were studied in detail for the first time. BpfA directly participates in biofilm formation as extracellular glue; BpfG is not only indispensable for BpfA export during biofilm forming but also functions to turn BpfA into active form for biofilm dispersing. BpfD regulates biofilm development by interacting with both BpfA and BpfG, likely in response to signal molecule c-di-GMP. In addition, we found that 1:1 stoichiometry between BpfD and BpfG is critical for biofilm formation. Furthermore, we demonstrated that a biofilm over-producing phenotype can be induced by C116S mutation but not loss of BpfG.

  3. Shewanella oneidensis: a new and efficient System for Expression and Maturation of heterologous [Fe-Fe] Hydrogenase from Chlamydomonas reinhardtii

    Directory of Open Access Journals (Sweden)

    Sybirna Kateryna

    2008-09-01

    Full Text Available Abstract Background The eukaryotic green alga, Chlamydomonas reinhardtii, produces H2 under anaerobic conditions, in a reaction catalysed by a [Fe-Fe] hydrogenase HydA1. For further biochemical and biophysical studies a suitable expression system of this enzyme should be found to overcome its weak expression in the host organism. Two heterologous expression systems used up to now have several advantages. However they are not free from some drawbacks. In this work we use bacterium Shewanella oneidensis as a new and efficient system for expression and maturation of HydA1 from Chlamydomonas reinhardtii. Results Based on codon usage bias and hydrogenase maturation ability, the bacterium S. oneidensis, which possesses putative [Fe-Fe] and [Ni-Fe] hydrogenase operons, was selected as the best potential host for C. reinhardtii [Fe-Fe] hydrogenase expression. Hydrogen formation by S. oneidensis strain AS52 (ΔhydAΔhyaB transformed with a plasmid bearing CrHydA1 and grown in the presence of six different substrates for anaerobic respiration was determined. A significant increase in hydrogen evolution was observed for cells grown in the presence of trimethylamine oxide, dimethylsulfoxide and disodium thiosulfate, showing that the system of S. oneidensis is efficient for heterologous expression of algal [Fe-Fe] hydrogenase. Conclusion In the present work a new efficient system for heterologous expression and maturation of C. reinhardtii hydrogenase has been developed. HydA1 of C. reinhardtii was purified and shown to contain 6 Fe atoms/molecule of protein, as expected. Using DMSO, TMAO or thiosulfate as substrates for anaerobic respiration during the cell growth, 0.4 – 0.5 mg l-1(OD600 = 1 of catalytically active HydA1 was obtained with hydrogen evolution rate of ~700 μmol H2 mg-1 min-1.

  4. High-field MR imaging of tethered cord

    International Nuclear Information System (INIS)

    Sigal, R.; Bicetre, L.; Blass, C.; Doyon, D.; Pariente, D.

    1986-01-01

    MR imaging examinations of 12 patients with tethered cord syndrome have been performed on a 1.5-T MR imaging unit. Patients ranged in age from 3 to 60 years. MR findings were compared with those of myelography and metrizamide CT in all cases. Five patients underwent surgical control and postoperative MR imaging. Sagittal and axial sections were obtained using a spin-echo multisection, multiecho technique. T1-axial weighted images (SE 600/25) were sufficient to locate the position of the tip of the conus. They also allowed identification of extraspinal and intraspinal lipomas and clear-cut demarcation form associated tethered cord. Drawbacks of MR imaging were lack of precise depiction of the bone structures and the fact that clear identification of abnormal roots was problematic. The craniovertebral junction was always checked; two asymptomatic Chiari malformations were visualized. This study leads the authors to conclude that MR imaging should be used as the examination of first choice in the management of tethered cord syndrome

  5. ORF Alignment: NC_004347 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available wanella oneidensis MR-1] ... Length = 97 ... Query: 2 ... WYMISAQDVENSLEKXXXXXXXXXXXXQELADEGRLLVAGPHPAIDSEN...PGDAGFSGSLV 61 ... WYMISAQDVENSLEK ... QELADEGRLLVAGPHPAIDSENPGDAGFS...GSLV Sbjct: 1 ... WYMISAQDVENSLEKRLAARPAHLARLQELADEGRLLVAGPHPAIDSENPGDAGFSGSLV 60 ...

  6. ORF Alignment: NC_004347 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available in ... [Shewanella oneidensis MR-1] ... Length = 108 ... Query: 5 ... LMFNGVDIERDHQGYLKNIADWHPDMAPLLAQEENIELTS...AHWEVINFVRDFYLEYKTSP 64 ... LMFNGVDIERDHQGYLKNIADWHPDMAPLLAQEENIELTS...AHWEVINFVRDFYLEYKTSP Sbjct: 1 ... LMFNGVDIERDHQGYLKNIADWHPDMAPLLAQEENIELTSAHWEVINFVRDFYLEYKTSP 60 ...

  7. ORF Alignment: NC_004347 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available ... [Shewanella oneidensis MR-1] ... Length = 151 ... Query: 1 ... MKITLDDLKGPEIAALLQEHLDDMRATSPPESVHALDLNG...LRQPNIRFWTLWDDRNLAGC 60 ... MKITLDDLKGPEIAALLQEHLDDMRATSPPESVHALDLNGLRQPNI...RFWTLWDDRNLAGC Sbjct: 1 ... MKITLDDLKGPEIAALLQEHLDDMRATSPPESVHALDLNGLRQPNIRFWTLWDDRNLAGC 60 ... Query: 121 RSLYAK

  8. ORF Alignment: NC_004347 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available rotein ... CinA [Shewanella oneidensis MR-1] ... Length = 160 ... Query: 1 ... MKLEMICTGEEVLSGQIVDTNAAWFASTM...MEHGIEIQRRVTVGDRLEDLIAVFQERSLHA 60 ... MKLEMICTGEEVLSGQIVDTNAAWFASTM...MEHGIEIQRRVTVGDRLEDLIAVFQERSLHA Sbjct: 1 ... MKLEMICTGEEVLSGQIVDTNAAWFASTMMEHGIEIQRRVTVGDRLEDLIAVFQERSLHA 6

  9. Deep learning for automatic localization, identification, and segmentation of vertebral bodies in volumetric MR images

    Science.gov (United States)

    Suzani, Amin; Rasoulian, Abtin; Seitel, Alexander; Fels, Sidney; Rohling, Robert N.; Abolmaesumi, Purang

    2015-03-01

    This paper proposes an automatic method for vertebra localization, labeling, and segmentation in multi-slice Magnetic Resonance (MR) images. Prior work in this area on MR images mostly requires user interaction while our method is fully automatic. Cubic intensity-based features are extracted from image voxels. A deep learning approach is used for simultaneous localization and identification of vertebrae. The localized points are refined by local thresholding in the region of the detected vertebral column. Thereafter, a statistical multi-vertebrae model is initialized on the localized vertebrae. An iterative Expectation Maximization technique is used to register the vertebral body of the model to the image edges and obtain a segmentation of the lumbar vertebral bodies. The method is evaluated by applying to nine volumetric MR images of the spine. The results demonstrate 100% vertebra identification and a mean surface error of below 2.8 mm for 3D segmentation. Computation time is less than three minutes per high-resolution volumetric image.

  10. MR imaging of the normal pancreas

    International Nuclear Information System (INIS)

    Itoh, Hisao; Takahashi, Norio; Uchida, Yoshie; Nakayama, Gen; Bito, Kaoru; Haba, Hirotsugu; Kawamura, Masashi; Kataoka, Masaaki; Hamamoto, Ken.

    1989-01-01

    To evaluate current 1.5-T MR imaging with respiratory ordered phase encoding (ROPE) technique in the identification of pancreatic contour and main pancreatic duct, 100 normal subjects examined with spin echo technique including transaxial scans of T 1 -WI,T 2 -WI, and proton density (PD)-WI were reviewed. The results of MR imaging were then compared with computed tomography (CT). Pancreatic contour was divided into 3 parts; head, body, and tail. T 1 -WI was the best pulse sequence in describing pancreas and the rates of specific identification of head, body, and tail were 69%, 97%, and 92%, respectively. While these rates were 62%, 90%, and 92% with plain CT and 69%, 94%, and 94% with contrast-enhanced CT, respectively. A combination of MR imaging and CT yielded better rates of identification. The main pancreatic duct was visible in 44% as a low intensity line on T 1 -WI and in 16% on plain CT. Dorsal to pancreas, all of the major vessels were seen in every patients. Ventrally, retroperitoneal fat was important, however, it was not a limiting factor. When respiratory compensation using ROPE functioned well, it was possible to differentiate bowel from pancreas in patients with sparse fat because signal intensity of the pancreas tended to be higher than that of gastrointestinal wall and its contents on T 1 -WI. Current MR imaging seemed to be a complementary method with CT in the identification of the pancreas. (author)

  11. ORF Alignment: NC_004347 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available ... [Shewanella oneidensis MR-1] ... Length = 145 ... Query: 292 QEASREPGQINKLIQDIAQAEANRDGEIELALADCPEA...LFQGLAIKRVLSNLVENAFRYG 351 ... QEASREPGQINKLIQDIAQAEANRDGEIELALADCPEALFQGL...AIKRVLSNLVENAFRYG Sbjct: 1 ... QEASREPGQINKLIQDIAQAEANRDGEIELALADCPEALFQGLAIKRVLSNLVENAFRYG 60 ... Query: 412 IDR

  12. Metabolic Characteristics of a Glucose-Utilizing Shewanella oneidensis Strain Grown under Electrode-Respiring Conditions.

    Directory of Open Access Journals (Sweden)

    Gen Nakagawa

    Full Text Available In bioelectrochemical systems, the electrode potential is an important parameter affecting the electron flow between electrodes and microbes and microbial metabolic activities. Here, we investigated the metabolic characteristics of a glucose-utilizing strain of engineered Shewanella oneidensis under electrode-respiring conditions in electrochemical reactors for gaining insight into how metabolic pathways in electrochemically active bacteria are affected by the electrode potential. When an electrochemical reactor was operated with its working electrode poised at +0.4 V (vs. an Ag/AgCl reference electrode, the engineered S. oneidensis strain, carrying a plasmid encoding a sugar permease and glucose kinase of Escherichia coli, generated current by oxidizing glucose to acetate and produced D-lactate as an intermediate metabolite. However, D-lactate accumulation was not observed when the engineered strain was grown with a working electrode poised at 0 V. We also found that transcription of genes involved in pyruvate and D-lactate metabolisms was upregulated at a high electrode potential compared with their transcription at a low electrode potential. These results suggest that the carbon catabolic pathway of S. oneidensis can be modified by controlling the potential of a working electrode in an electrochemical bioreactor.

  13. Towards structural studies of the old yellow enzyme homologue SYE4 from Shewanella oneidensis and its complexes at atomic resolution

    International Nuclear Information System (INIS)

    Elegheert, Jonathan; Hemel, Debbie van den; Dix, Ina; Stout, Jan; Van Beeumen, Jozef; Brigé, Ann; Savvides, Savvas N.

    2009-01-01

    Of the four old yellow enzyme homologues found in S. oneidensis, SYE4 is the homologue most implicated in resistance to oxidative stress. SYE4 was recombinantly expressed in Escherichia coli, purified and crystallized using the hanging-drop vapour-diffusion method. Shewanella oneidensis is an environmentally versatile Gram-negative γ-proteobacterium that is endowed with an unusually large proteome of redox proteins. Of the four old yellow enzyme (OYE) homologues found in S. oneidensis, SYE4 is the homologue most implicated in resistance to oxidative stress. SYE4 was recombinantly expressed in Escherichia coli, purified and crystallized using the hanging-drop vapour-diffusion method. The crystals belonged to the orthorhombic space group P2 1 2 1 2 1 and were moderately pseudo-merohedrally twinned, emulating a P422 metric symmetry. The native crystals of SYE4 were of exceptional diffraction quality and provided complete data to 1.10 Å resolution using synchrotron radiation, while crystals of the reduced enzyme and of the enzyme in complex with a wide range of ligands typically led to high-quality complete data sets to 1.30–1.60 Å resolution, thus providing a rare opportunity to dissect the structure–function relationships of a good-sized enzyme (40 kDa) at true atomic resolution. Here, the attainment of a number of experimental milestones in the crystallographic studies of SYE4 and its complexes are reported, including isolation of the elusive hydride–Meisenheimer complex

  14. Metabolic Profiling Directly from the Petri Dish Using Nanospray Desorption Electrospray Ionization Imaging Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Watrous, Jeramie D.; Roach, Patrick J.; Heath, Brandi S.; Alexandrov, Theodore; Laskin, Julia; Dorrestein, Pieter C.

    2013-11-05

    Understanding molecular interaction pathways in complex biological systems constitutes a treasure trove of knowledge that might facilitate the specific, chemical manipulation of the countless microbiological systems that occur throughout our world. However, there is a lack of methodologies that allow the direct investigation of chemical gradients and interactions in living biological systems, in real time. Here, we report the use of nanospray desorption electrospray ionization (nanoDESI) imaging mass spectrometry for in vivo metabolic profiling of living bacterial colonies directly from the Petri dish with absolutely no sample preparation needed. Using this technique, we investigated single colonies of Shewanella oneidensis MR-1, Bacillus subtilis 3610, and Streptomyces coelicolor A3(2) as well as a mixed biofilm of S. oneidensis MR-1 and B. subtilis 3610. Data from B. subtilis 3610 and S. coelicolor A3(2) provided a means of validation for the method while data from S. oneidensis MR-1 and the mixed biofilm showed a wide range of compounds that this bacterium uses for the dissimilatory reduction of extracellular metal oxides, including riboflavin, iron-bound heme and heme biosynthetic intermediates, and the siderophore putrebactin.

  15. Pathway confirmation and flux analysis of central metabolicpathways in Desulfovibrio vulgaris Hildenborough using gaschromatography-mass spectrometry and fourier transform-ion cyclotronresonance mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yinjie; Pingitore, Francesco; Mukhopadhyay, Aindrila; Phan,Richard; Hazen, Terry C.; Keasling, Jay D.

    2006-07-11

    It has been proposed that during growth under anaerobic oroxygen-limited conditions Shewanella oneidensis MR-1 uses theserine-isocitrate lyase pathway common to many methylotrophic anaerobes,in which formaldehyde produced from pyruvate is condensed with glycine toform serine. The serine is then transformed through hydroxypyruvate andglycerate to enter central metabolism at phosphoglycerate. To examine itsuse of the serine-isocitrate lyase pathway under anaerobic conditions, wegrew S. oneidensis MR-1 on [1-13C]lactate as the sole carbon source witheither trimethylamine N-oxide (TMAO) or fumarate as an electron acceptor.Analysis of cellular metabolites indicates that a large percentage(>75 percent) of lactate was partially oxidized to either acetate orpyruvate. The 13C isotope distributions in amino acids and other keymetabolites indicate that, under anaerobic conditions, a complete serinepathway is not present, and lactate is oxidized via a highly reversibleserine degradation pathway. The labeling data also suggest significantactivity in the anaplerotic (malic enzyme and phosphoenolpyruvatecarboxylase) and glyoxylate shunt (isocitrate lyase and malate synthase)reactions. Although the tricarboxylic acid (TCA) cycle is often observedto be incomplete in many other anaerobes (absence of 2-oxoglutaratedehydrogenase activity), isotopic labeling supports the existence of acomplete TCA cycle in S. oneidensis MR-1 under TMAO reductioncondition.

  16. Direct spondylolisthesis identification and measurement in MR/CT using detectors trained by articulated parameterized spine model

    Science.gov (United States)

    Cai, Yunliang; Leung, Stephanie; Warrington, James; Pandey, Sachin; Shmuilovich, Olga; Li, Shuo

    2017-02-01

    The identification of spondylolysis and spondylolisthesis is important in spinal diagnosis, rehabilitation, and surgery planning. Accurate and automatic detection of spinal portion with spondylolisthesis problem will significantly reduce the manual work of physician and provide a more robust evaluation for the spine condition. Most existing automatic identification methods adopted the indirect approach which used vertebrae locations to measure the spondylolisthesis. However, these methods relied heavily on automatic vertebra detection which often suffered from the pool spatial accuracy and the lack of validated pathological training samples. In this study, we present a novel spondylolisthesis detection method which can directly locate the irregular spine portion and output the corresponding grading. The detection is done by a set of learning-based detectors which are discriminatively trained by synthesized spondylolisthesis image samples. To provide sufficient pathological training samples, we used a parameterized spine model to synthesize different types of spondylolysis images from real MR/CT scans. The parameterized model can automatically locate the vertebrae in spine images and estimate their pose orientations, and can inversely alter the vertebrae locations and poses by changing the corresponding parameters. Various training samples can then be generated from only a few spine MR/CT images. The preliminary results suggest great potential for the fast and efficient spondylolisthesis identification and measurement in both MR and CT spine images.

  17. Snapshot of iron response in Shewanella oneidensis by gene network reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yunfeng; Harris, Daniel P.; Luo, Feng; Xiong, Wenlu; Joachimiak, Marcin; Wu, Liyou; Dehal, Paramvir; Jacobsen, Janet; Yang, Zamin; Palumbo, Anthony V.; Arkin, Adam P.; Zhou, Jizhong

    2008-10-09

    Background: Iron homeostasis of Shewanella oneidensis, a gamma-proteobacterium possessing high iron content, is regulated by a global transcription factor Fur. However, knowledge is incomplete about other biological pathways that respond to changes in iron concentration, as well as details of the responses. In this work, we integrate physiological, transcriptomics and genetic approaches to delineate the iron response of S. oneidensis. Results: We show that the iron response in S. oneidensis is a rapid process. Temporal gene expression profiles were examined for iron depletion and repletion, and a gene co-expression network was reconstructed. Modules of iron acquisition systems, anaerobic energy metabolism and protein degradation were the most noteworthy in the gene network. Bioinformatics analyses suggested that genes in each of the modules might be regulated by DNA-binding proteins Fur, CRP and RpoH, respectively. Closer inspection of these modules revealed a transcriptional regulator (SO2426) involved in iron acquisition and ten transcriptional factors involved in anaerobic energy metabolism. Selected genes in the network were analyzed by genetic studies. Disruption of genes encoding a putative alcaligin biosynthesis protein (SO3032) and a gene previously implicated in protein degradation (SO2017) led to severe growth deficiency under iron depletion conditions. Disruption of a novel transcriptional factor (SO1415) caused deficiency in both anaerobic iron reduction and growth with thiosulfate or TMAO as an electronic acceptor, suggesting that SO1415 is required for specific branches of anaerobic energy metabolism pathways. Conclusions: Using a reconstructed gene network, we identified major biological pathways that were differentially expressed during iron depletion and repletion. Genetic studies not only demonstrated the importance of iron acquisition and protein degradation for iron depletion, but also characterized a novel transcriptional factor (SO1415) with a

  18. Transcriptome analysis reveals a stress response of Shewanella oneidensis deprived of background levels of ionizing radiation

    Science.gov (United States)

    Li, Xiaoping; Schilkey, Faye; Smith, Geoffrey B.

    2018-01-01

    Natural ionizing background radiation has exerted a constant pressure on organisms since the first forms of life appeared on Earth, so that cells have developed molecular mechanisms to avoid or repair damages caused directly by radiation or indirectly by radiation-induced reactive oxygen species (ROS). In the present study, we investigated the transcriptional effect of depriving Shewanella oneidensis cultures of background levels of radiation by growing the cells in a mine 655 m underground, thus reducing the dose rate from 72.1 to 0.9 nGy h-1 from control to treatment, respectively. RNASeq transcriptome analysis showed the differential expression of 4.6 and 7.6% of the S. oneidensis genome during early- and late-exponential phases of growth, respectively. The greatest change observed in the treatment was the downregulation of ribosomal proteins (21% of all annotated ribosomal protein genes during early- and 14% during late-exponential) and tRNA genes (14% of all annotated tRNA genes in early-exponential), indicating a marked decrease in protein translation. Other significant changes were the upregulation of membrane transporters, implying an increase in the traffic of substrates across the cell membrane, as well as the up and downregulation of genes related to respiration, which could be interpreted as a response to insufficient oxidants in the cells. In other reports, there is evidence in multiple species that some ROS not just lead to oxidative stress, but act as signaling molecules to control cellular metabolism at the transcriptional level. Consistent with these reports, several genes involved in the metabolism of carbon and biosynthesis of amino acids were also regulated, lending support to the idea of a wide metabolic response. Our results indicate that S. oneidensis is sensitive to the withdrawal of background levels of ionizing radiation and suggest that a transcriptional response is required to maintain homeostasis and retain normal growth. PMID:29768440

  19. Dehydrochlorination of 1,1,1-trichloroethane and pentachloroethane by microbially reduced ferruginous smectite.

    Science.gov (United States)

    Cervini-Silva, Javiera; Kostka, Joel E; Larson, Richard A; Stucki, Joseph W; Wu, Jun

    2003-05-01

    Reduction of structural Fe(III) in smectite clay minerals has been identified as a means to promote dechlorination of polychlorinated ethanes, but its environmental significance has yet to be fully assessed because Fe reduction has normally been achieved by agents uncommon in the environment (e.g., dithionite). This study reports the dehydrochlorination of pentachloroethane and 1,1,1-trichloroethane in the presence of ferruginous smectite reduced by two cultures of microorganisms, Shewanella oneidensis strain MR-1 (MR-R) and an enrichment culture from rice paddy soils (PS-R), in aqueous suspension under anoxic conditions. Microbially reduced ferruginous smectite facilitated dehydrochlorination of 1,1,1-trichloroethane to 1,1-dichloroethene with up to 60% conversion within 3 h of incubation time. In contrast, no formation of 1,1-dichloroethene was observed after incubation of 1,1,1-trichloroethane with chemically reduced ferruginous smectite for 24 h. Microbially reduced ferruginous smectite by MR-R and PS-R promoted the dehydrochlorination of pentachloroethane to tetrachloroethene by 80 and 15%, respectively, after 3 h of incubation time. The conversion of pentachloroethane to tetrachloroethene in the presence of chemically reduced ferruginous smectite after 24 h was 65%. These results indicate that structural Fe(II) in clay minerals has the potential to be an important reductant controlling the fate of organic chemicals in contaminated sediments.

  20. Deletion of Lytic Transglycosylases Increases Beta-Lactam Resistance in Shewanella oneidensis

    Science.gov (United States)

    Yin, Jianhua; Sun, Yiyang; Sun, Yijuan; Yu, Zhiliang; Qiu, Juanping; Gao, Haichun

    2018-01-01

    Production of chromosome-encoded β-lactamases confers resistance to β-lactams in many Gram-negative bacteria. Some inducible β-lactamases, especially the class C β-lactamase AmpC in Enterobacteriaceae, share a common regulatory mechanism, the ampR-ampC paradigm. Induction of ampC is intimately linked to peptidoglycan recycling, and the LysR-type transcriptional regulator AmpR plays a central role in the process. However, our previous studies have demonstrated that the expression of class D β-lactamase gene blaA in Shewanella oneidensis is distinct from the established paradigm since an AmpR homolog is absent and major peptidoglycan recycling enzymes play opposite roles in β-lactamase expression. Given that lytic transglycosylases (LTs), a class of peptidoglycan hydrolases cleaving the β-1,4 glycosidic linkage in glycan strands of peptidoglycan, can disturb peptidoglycan recycling, and thus may affect induction of blaA. In this study, we investigated impacts of such enzymes on susceptibility to β-lactams. Deletion of three LTs (SltY, MltB and MltB2) increased β-lactam resistance, while four other LTs (MltD, MltD2, MltF, and Slt2) seemed dispensable to β-lactam resistance. The double LT mutants ΔmltBΔmltB2 and ΔsltYΔmltB2 had β-lactam resistance stronger than any of the single mutants. Deletion of ampG (encoding permease AmpG) and mrcA (encoding penicillin binding protein 1a, PBP1a) from both double LT mutants further increased the resistance to β-lactams. Notably, all increased β-lactam resistance phenotypes were in accordance with enhanced blaA expression. Although significant, the increase in β-lactamase activity after inactivating LTs is much lower than that produced by PBP1a inactivation. Our data implicate that LTs play important roles in blaA expression in S. oneidensis. PMID:29403465

  1. MR imaging of breast implants.

    Science.gov (United States)

    Gorczyca, D P

    1994-11-01

    MR imaging has proved to be an excellent imaging modality in locating free silicone and evaluating an implant for rupture, with a sensitivity of approximately 94% and specificity of 97%. Silicone has a unique MR resonance frequency and long T1 and T2 relaxation times, which allows several MR sequences to provide excellent diagnostic images. The most commonly used sequences include T2-weighted, STIR, and chemical shift imaging (Figs. 3, 13, and 14). The T2-weighted and STIR sequences are often used in conjunction with chemical water suppression. The most reliable findings on MR images for detection of implant rupture include identification of the collapsed implant shell (linguine sign) and free silicone within the breast parenchyma.

  2. Bioelectrochemical biosensor for water toxicity detection: generation of dual signals for electrochemical assay confirmation.

    Science.gov (United States)

    Yang, Yuan; Wang, Yan-Zhai; Fang, Zhen; Yu, Yang-Yang; Yong, Yang-Chun

    2018-02-01

    Toxicity assessment of water is of great important to the safety of human health and to social security because of more and more toxic compounds that are spilled into the aquatic environment. Therefore, the development of fast and reliable toxicity assessment methods is of great interest and attracts much attention. In this study, by using the electrochemical activity of Shewanella oneidensis MR-1 cells as the toxicity indicator, 3,5-dichlorophenol (DCP) as the model toxic compound, a new biosensor for water toxicity assessment was developed. Strikingly, the presence of DCP in the water significantly inhibited the maximum current output of the S. oneidensis MR-1 in a three-electrode system and also retarded the current evolution by the cells. Under the optimized conditions, the maximum current output of the biosensor was proportional to the concentration of DCP up to 30 mg/L. The half maximal inhibitory concentration of DCP determined by this biosensor is about 14.5 mg/L. Furthermore, simultaneous monitoring of the retarded time (Δt) for current generation allowed the identification of another biosensor signal in response to DCP which could be employed to verify the electrochemical result by dual confirmation. Thus, the present study has provided a reliable and promising approach for water quality assessment and risk warning of water toxicity.

  3. Charge-associated effects of fullerene derivatives on microbialstructural integrity and central metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yinjie J.; Ashcroft, Jared M.; Chen, Ding; Min, Guangwei; Kim, Chul; Murkhejee, Bipasha; Larabell, Carolyn; Keasling, Jay D.; Chen,Fanqing Frank

    2007-01-23

    The effects of four types of fullerene compounds (C60,C60-OH, C60-COOH, C60-NH2) were examined on two model microorganisms(Escherichia coli W3110 and Shewanella oneidensis MR-1). Positivelycharged C60-NH2 at concentrations as low as 10 mg/L inhibited growth andreduced substrate uptake for both microorganisms. Scanning ElectronMicroscopy (SEM) revealed damage to cellular structures.Neutrally-charged C60 and C60-OH had mild negative effects on S.oneidensis MR-1, whereas the negatively-charged C60-COOH did not affecteither microorganism s growth. The effect of fullerene compounds onglobal metabolism was further investigated using [3-13C]L-lactateisotopic labeling, which tracks perturbations to metabolic reaction ratesin bacteria by examining the change in the isotopic labeling pattern inthe resulting metabolites (often amino acids).1-3 The 13C isotopomeranalysis from all fullerene-exposed cultures revealed no significantdifferences in isotopomer distributions from unstressed cells. Thisresult indicates that microbial central metabolism is robust toenvironmental stress inflicted by fullerene nanoparticles. In addition,although C60-NH2 compounds caused mechanical stress on the cell wall ormembrane, both S. oneidensis MR-1 and E. coli W3110 can efficientlyalleviate such stress by cell aggregation and precipitation of the toxicnanoparticles. The results presented here favor the hypothesis thatfullerenes cause more membrane stress4, 5, 6 than perturbation to energymetabolism7

  4. Pathway confirmation and flux analysis of central metabolic pathways in Desulfovibrio vulgaris Hildenborough using gas chromatography-mass spectrometry and fourier transform-ion cyclotron resonance mass spectrometry

    International Nuclear Information System (INIS)

    Tang, Yinjie; Pingitore, Francesco; Mukhopadhyay, Aindrila; Phan, Richard; Hazen, Terry C.; Keasling, Jay D.

    2006-01-01

    It has been proposed that during growth under anaerobic or oxygen-limited conditions Shewanella oneidensis MR-1 uses the serine-isocitrate lyase pathway common to many methylotrophic anaerobes, in which formaldehyde produced from pyruvate is condensed with glycine to form serine. The serine is then transformed through hydroxypyruvate and glycerate to enter central metabolism at phosphoglycerate. To examine its use of the serine-isocitrate lyase pathway under anaerobic conditions, we grew S. oneidensis MR-1 on [1-13C] lactate as the sole carbon source with either trimethylamine N-oxide (TMAO) or fumarate as an electron acceptor. Analysis of cellular metabolites indicates that a large percentage (>75 percent) of lactate was partially oxidized to either acetate or pyruvate. The 13C isotope distributions in amino acids and other key metabolites indicate that, under anaerobic conditions, a complete serine pathway is not present, and lactate is oxidized via a highly reversible serine degradation pathway. The labeling data also suggest significant activity in the anaplerotic (malic enzyme and phosphoenolpyruvatecarboxylase) and glyoxylate shunt (isocitrate lyase and malate synthase) reactions. Although the tricarboxylic acid (TCA) cycle is often observed to be incomplete in many other anaerobes (absence of 2-oxoglutaratede hydrogenase activity), isotopic labeling supports the existence of a complete TCA cycle in S. oneidensis MR-1 under TMAO reduction condition

  5. CT and MR imaging of craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Takahashi, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Higano, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Kurihara, N. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Ikeda, H. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Neurosurgery; Sakamoto, K. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology

    1997-05-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  6. CT and MR imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Tsuda, M.; Takahashi, S.; Higano, S.; Kurihara, N.; Ikeda, H.; Sakamoto, K.

    1997-01-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  7. MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto; Neumaier, Carlo Emanuele; Calabrese, Massimo [National Institute for Cancer Research, Department of Radiology, Genova (Italy); Succio, Giulia; Serafini, Giovanni; Ghidara, Matteo [Santa Corona Hospital, Radiology Department, Savona (Italy); Martinoli, Carlo [Universita di Genova, Radiology Department, Genova (Italy)

    2011-06-15

    To compare 1.5-T and 3-T magnetic resonance (MR) imaging of the brachial plexus. Institutional review board approval and informed consent were obtained from 30 healthy volunteers and 30 consecutive patients with brachial plexus disturbances. MR was prospectively performed with comparable sequence parameters and coils with a 1.5-T and a 3-T system. Imaging protocols at both field strengths included T1-weighted turbo spin-echo (tSE) sequences and T2-weighed turbo spin-echo (tSE) sequences with fat saturation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) between muscle and nerve were calculated for both field strengths. The visibility of brachial plexus nerve at various anatomic levels (roots, interscalene area, costoclavicular space, and axillary level) was analyzed with a four-point grading scale by two radiologists. MR imaging diagnoses and pathological findings were also compared qualitatively. SNR and CNRs were significantly higher on 3-T MR images than on 1.5-T MR images (Friedman test) for all sequences. Nerve visibility was significantly better on 3-T MR images than on 1.5-T MR images (paired sign test). Pathological findings (n = 30/30) were seen equally well with both field strengths. MR imaging diagnoses did not differ for the 1.5- and 3-T protocols. High-quality MR images of the brachial plexus can be obtained with 3-T MR imaging by using sequences similar to those used at 1.5-T MR imaging. In patients and healthy volunteers, the visibility of nerve trunks and cords at 3-T MR imaging appears to be superior to that at 1.5-T MR imaging. (orig.)

  8. Bion M1. Peculiarities of life activities of microbes in 30-day spaceflight

    Science.gov (United States)

    Viacheslav, Ilyin; Korshunov, Denis; Morozova, Julia; Voeikova, Tatiana; Tyaglov, Boris; Novikova, Liudmila; Krestyanova, Irina; Emelyanova, Lydia

    The aim of this work was to analyze the influence of space flight factors ( SFF) to microorganism strains , exposed inside unmanned spacecraft Bion M-1 during the 30- day space flight. Objectives of the work - the study of the influence of the SFF exchange chromosomal DNA in crosses microorganisms of the genus Streptomyces; the level of spontaneous phage induction of lysogenic strains fS31 from Streptomyces lividans 66 and Streptomyces coelicolor A3 ( 2 ) on the biosynthesis of the antibiotic tylosin strain of Streptomyces fradiae; survival electrogenic bacteria Shewanella oneidensis MR- 1 is used in the microbial fuel cell As a result of this work it was found that the SFF affect the exchange of chromosomal DNA by crossing strains of Streptomyces. Was detected polarity crossing , expressed in an advantageous contribution chromosome fragment of one of the parent strains in recombinant offspring. This fact may indicate a more prolonged exposure of cells in microgravity and , as a consequence, the transfer of longer fragments of chromosomal DNA This feature is the transfer of genetic material in microgravity could lead to wider dissemination and horizontal transfer of chromosomal and plasmid DNA of symbiotic microflora astronauts and other strains present in the spacecraft. It was shown no effect on the frequency of recombination PCF and the level of mutation model reversion of auxotrophic markers to prototrophy It was demonstrated that PCF increase the level of induction of cell actinophage fS31 lysogenic strain of S. lividans 66, but did not affect the level of induction of this phage cells S. coelicolor A3 ( 2). It is shown that the lower the level of synthesis PCF antibiotic aktinorodina (actinorhodin) in lysogenic strain S. coelicolor A3 ( 2). 66 Strains of S. lividans and S. coelicolor A3 ( 2 ) can be used as a biosensor for studying the effect on microorganisms PCF It is shown that the effect of the PCF reduces synthesis of tylosin and desmicosyn S. fradiae at

  9. Gadolinium-enhanced T{sub 1}-weighted MR urography versus T{sub 2}-weighted (HASTE) MR urography in children; Kontrastangehobene T{sub 1}-gewichtete MR-Urographie versus T{sub 2}-gewichtete (HASTE) MR-Urographie im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G.; Nolte-Ernsting, C.C.A.; Haage, P.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohrmann, D. [Technische Hochschule Aachen (Germany). Urologische Klinik; Stollbrink, C. [Technische Hochschule Aachen (Germany). Kinderklinik

    2001-11-01

    Purpose: To evaluate gadolinium-enhanced T{sub 1}-weighted excretory MR urography (EMRU) versus T{sub 2}-weighted (HASTE) MR urography in children with upper urinary tract abnormalities. Patients and Methods: In a prospective study 63 children, aged from 3 weeks to 15 years, underwent MR urography in a 1.5-T scanner. Before and after an intravenous injection of 0.05 mg/kg body weight of furosemide, respiratory-triggered HASTE images were obtained for T{sub 2}-weighted MR urography. EMRU was performed subsequent to i.v. gadolinium injection with respiratory-gated, coronal 3D-gradient-echo sequences. Results: Compared to T{sub 2}-weighted (HASTE) MR urography, gadolinium-enhanced MR urography revealed a superior diagnostic accuracy in non-dilated collecting systems (horseshoe kidneys, ectopic kidneys, duplex systems, single ectopic ureters, ureteroceles). EMRU and T{sub 2}-weighted (HASTE) MRU turned out to be equivalent in the assessment of obstructed but normal functioning upper urinary tracts (UPJ obstructions, megaureters). Non-functioning dilated collecting systems and multicystic dysplastic kidneys were best visualized with use of T{sub 2}-weighted (HASTE) MR urography. Conclusion: Respiratory-gated gadolinium-enhanced T{sub 1}-weighted MRU allows accurate evaluation of most upper urinary tract abnormalities. T{sub 2}-weighted (HASTE) MRU complements GMRU in the evaluation of non-functioning renal units and cystic disease of the kidneys. (orig.) [German] Ziel: Vergleich der kontrastangehobenen T{sub 1}-gewichteten MR-Urographie mit der T{sub 2}-gewichteten (HASTE) MR-Urographie bei Kindern mit Anomalien des oberen Harntraktes. Methoden: In einer prospektiven Studie wurde bei 63 Kindern (3 Wo. - 15J.) eine MR-Urographie (MRU) in einem 1,5-Tesla-Magneten durchgefuehrt. Die T{sub 2}-gewichtete MRU erfolgte vor und nach intravenoeser Injektion von 0,05 mg/kg KG Furosemid mit atemgetriggerten HASTE-Sequenzen. Fuer die T{sub 1}-gewichtete MRU wurden nach

  10. Comparative Genomics Analysis and Phenotypic Characterization of Shewanella putrefaciens W3-18-1: Anaerobic Respiration, Bacterial Microcompartments, and Lateral Flagella

    International Nuclear Information System (INIS)

    Qiu, D.; Tu, Q.; He, Zhili; Zhou, Jizhong

    2010-01-01

    Respiratory versatility and psychrophily are the hallmarks of Shewanella. The ability to utilize a wide range of electron acceptors for respiration is due to the large number of c-type cytochrome genes present in the genome of Shewanella strains. More recently the dissimilatory metal reduction of Shewanella species has been extensively and intensively studied for potential applications in the bioremediation of radioactive wastes of groundwater and subsurface environments. Multiple Shewanella genome sequences are now available in the public databases (Fredrickson et al., 2008). Most of the sequenced Shewanella strains were isolated from marine environments and this genus was believed to be of marine origin (Hau and Gralnick, 2007). However, the well-characterized model strain, S. oneidensis MR-1, was isolated from the freshwater lake sediment of Lake Oneida, New York (Myers and Nealson, 1988) and similar bacteria have also been isolated from other freshwater environments (Venkateswaran et al., 1999). Here we comparatively analyzed the genome sequence and physiological characteristics of S. putrefaciens W3-18-1 and S. oneidensis MR-1, isolated from the marine and freshwater lake sediments, respectively. The anaerobic respirations, carbon source utilization, and cell motility have been experimentally investigated. Large scale horizontal gene transfers have been revealed and the genetic divergence between these two strains was considered to be critical to the bacterial adaptation to specific habitats, freshwater or marine sediments.

  11. Clinical stage T1c prostate cancer: evaluation with endorectal MR imaging and MR spectroscopic imaging.

    Science.gov (United States)

    Zhang, Jingbo; Hricak, Hedvig; Shukla-Dave, Amita; Akin, Oguz; Ishill, Nicole M; Carlino, Lauren J; Reuter, Victor E; Eastham, James A

    2009-11-01

    To assess the diagnostic accuracy of endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging for prediction of the pathologic stage of prostate cancer and the presence of clinically nonimportant disease in patients with clinical stage T1c prostate cancer. The institutional review board approved-and waived the informed patient consent requirement for-this HIPAA-compliant study involving 158 patients (median age, 58 years; age range, 40-76 years) who had clinical stage T1c prostate cancer, had not been treated preoperatively, and underwent combined 1.5-T endorectal MR imaging-MR spectroscopic imaging between January 2003 and March 2004 before undergoing radical prostatectomy. On the MR images and combined endorectal MR-MR spectroscopic images, two radiologists retrospectively and independently rated the likelihood of cancer in 12 prostate regions and the likelihoods of extracapsular extension (ECE), seminal vesicle invasion (SVI), and adjacent organ invasion by using a five-point scale, and they determined the probability of clinically nonimportant prostate cancer by using a four-point scale. Whole-mount step-section pathology maps were used for imaging-pathologic analysis correlation. Receiver operating characteristic curves were constructed and areas under the curves (AUCs) were estimated nonparametrically for assessment of reader accuracy. At surgical-pathologic analysis, one (0.6%) patient had no cancer; 124 (78%) patients, organ-confined (stage pT2) disease; 29 (18%) patients, ECE (stage pT3a); two (1%) patients, SVI (stage pT3b); and two (1%) patients, bladder neck invasion (stage pT4). Forty-six (29%) patients had a total tumor volume of less than 0.5 cm(3). With combined MR imaging-MR spectroscopic imaging, the two readers achieved 80% accuracy in disease staging and AUCs of 0.62 and 0.71 for the prediction of clinically nonimportant cancer. Clinical stage T1c prostate cancers are heterogeneous in pathologic stage and volume. MR imaging may

  12. 3D dynamic pituitary MR imaging with CAIPIRINHA: Initial experience and comparison with 2D dynamic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fushimi, Yasutaka, E-mail: yfushimi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Okada, Tomohisa; Kanagaki, Mitsunori; Yamamoto, Akira; Kanda, Yumiko; Sakamoto, Ryo [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Hojo, Masato; Takahashi, Jun C.; Miyamoto, Susumu [Department of Neurosurgery, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan)

    2014-10-15

    Objectives: To evaluate the validity of 3D dynamic pituitary MR imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA), with special emphasis on demarcation of pituitary posterior lobe and stalk. Methods: Participants comprised 32 patients who underwent dynamic pituitary MR imaging due to pituitary or parasellar lesions. 3D dynamic MR with CAIPIRINHA was performed at 3 T with 20-s-interval, precontrast, 1st to 5th dynamic images. Normalized values and enhanced ratios (dynamic postcontrast image values divided by precontrast ones) were compared between 3D and 2D dynamic MR imaging for patients with visual identification of posterior lobe and stalk. Results: In 3D, stalk was identified in 29 patients and unidentified in 3, and posterior lobe was identified in 28 and unidentified in 4. In 2D, stalk was identified in 26 patients and unidentified in 6 patients, and posterior lobe was identified in 15 and unidentified in 17. Normalized values of pituitary posterior lobe and stalk were higher in 3D than 2D (P < 0.001). No significant difference in enhancement ratio was seen between 3D and 2D. Conclusions: 3D dynamic pituitary MR provided better identification and higher normalized values of pituitary posterior lobe and stalk than 2D.

  13. Adoptive T cell therapy targeting CD1 and MR1

    Directory of Open Access Journals (Sweden)

    Tingxi eGuo

    2015-05-01

    Full Text Available Adoptive T cell immunotherapy has demonstrated clinically relevant efficacy in treating malignant and infectious diseases. However, much of these therapies have been focused on enhancing, or generating de novo, effector functions of conventional T cells recognizing HLA molecules. Given the heterogeneity of HLA alleles, mismatched patients are ineligible for current HLA-restricted adoptive T cell therapies. CD1 and MR1 are class I-like monomorphic molecules and their restricted T cells possess unique T cell receptor specificity against entirely different classes of antigens. CD1 and MR1 molecules present lipid and vitamin B metabolite antigens, respectively, and offer a new front of targets for T cell therapies. This review will cover the recent progress in the basic research of CD1, MR1, and their restricted T cells that possess translational potential.

  14. Serial MR imaging and 1H-MR spectroscopy in monozygotic twins with Tay-Sachs disease.

    Science.gov (United States)

    Imamura, A; Miyajima, H; Ito, R; Orii, K O

    2008-10-01

    Four-year-old monozygotic female twins with early onset Tay-Sachs disease are described. The sisters showed similar slowly progressive clinical symptoms and deterioration, however the younger sister also demonstrated intractable myoclonus in the right leg. The serial MR images and (1)H-MR spectroscopy of the brain were obtained in both twins. MR images showed high intensity on T (2)-weighted image in the bilateral white matter, however there were no signal changes in the basal ganglia and thalamus during any of the phases. The ratio of N-acetylaspartate (NAA)/creatine (Cr) was decreased in the both white matter lesions and the corpus striatum, and that of myoinositol (mI)/Cr was increased in the damaged white matter on MR spectroscopy. The elevation of the lactate peak was clearly demonstrated in the left basal ganglia of the younger sister; however it was not shown in cerebral lesions of the elder sister. Changes in metabolites on MR spectroscopy were closely linked to the respective clinical features of each twin. Follow-up examination by (1)H-MR spectroscopy is useful for the evaluation of neuronal changes in children with Tay-Sachs disease.

  15. Functional MR imaging on an open 1T MR imaging system: exploiting the advantages of an open MR imaging system for functional MR imaging

    NARCIS (Netherlands)

    van de Giessen, E.; Groot, P. F. C.; Booij, J.; van den Brink, W.; Veltman, D. J.; Nederveen, A. J.

    2011-01-01

    Open MR imaging scanners are designed for imaging of specific patient groups that cannot be routinely scanned with conventional MR imaging scanners (eg, patients with obesity and claustrophobia). This study aims to determine whether BOLD sensitivity on an open 1T scanner is adequate for fMRI for

  16. Identification of acute myocardial infarction with MR imaging by using combined assessment of regional wall motion and Gd-DTPA uptake

    International Nuclear Information System (INIS)

    Roos, A. de; Matheijssen, N.A.A.; Doornbos, J.; van Dijkman, P.; Pattynama, P.; van der Wall, E.

    1990-01-01

    This paper evaluates the usefulness of MR imaging for identification of acute myocardial infarction (AMI) in clinical patients, based on the assessment of regional wall motion abnormalities in conjunction with local uptake of Gd-DTPA. Fourteen patients with proved AMI and 12 normal volunteers underwent multisection-multiphase MR imaging in the short-axis plane encompassing the entire left ventricle. Gd-DTPA (0.2 mmol/kg) was injected in all patients to enhance the infarcted region. MR cine loops of the patients and volunteers were blinded and displayed. Three experienced observers scored the cine loops in consensus as to the presence or absence of AMI, noting wall motion abnormalities and/or increased Gd-DTPA uptake

  17. Myofibrillogenesis regulator 1 (MR-1 is a novel biomarker and potential therapeutic target for human ovarian cancer

    Directory of Open Access Journals (Sweden)

    Feng Jingjing

    2011-06-01

    Full Text Available Abstract Background Myofibrillogenesis regulator 1 (MR-1 is overexpressed in human cancer cells and plays an essential role in cancer cell growth. However, the significance of MR-1 in human ovarian cancer has not yet been explored. The aim of this study was to examine whether MR-1 is a predictor of ovarian cancer and its value as a therapeutic target in ovarian cancer patients. Methods Reverse-transcription polymerase chain reaction (PCR and quantitative real-time PCR were used to detect MR-1 mRNA levels in tissue samples from 26 ovarian cancer patients and 25 controls with benign ovarian disease. Anti-MR-1 polyclonal antibodies were prepared, tested by ELISA and western blotting, and then used for immunohistochemical analysis of the tissue samples. Adhesion and invasion of 292T cells was also examined after transfection of a pMX-MR-1 plasmid. Knockdown of MR-1 expression was achieved after stable transfection of SKOV3 cells with a short hairpin DNA pGPU6/GFP/Neo plasmid against the MR-1 gene. In addition, SKOV3 cells were treated with paclitaxel and carboplatin, and a potential role for MR-1 as a therapeutic target was evaluated. Results MR-1 was overexpressed in ovarian cancer tissues and SKOV3 cells. 293T cells overexpressed MR-1, and cellular spread and invasion were enhanced after transfection of the pMX-MR-1 plasmid, suggesting that MR-1 is critical for ovarian cancer cell growth. Knockdown of MR-1 expression inhibited cell adhesion and invasion, and treatment with anti-cancer drugs decreased its expression in cancer cells. Taken together, these results provide the first evidence of the cellular and molecular mechanisms by which MR-1 might serve as a novel biological marker and potential therapeutic target for ovarian cancer. Conclusions MR-1 may be a biomarker for diagnosis of ovarian cancer. It may also be useful for monitoring of the effects of anti-cancer therapies. Further studies are needed to clarify whether MR-1 is an early

  18. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  19. Dynamic MR-mammography in invasive lobular breast cancer; Dynamische MR-Mammographie beim invasiv lobulaeren Mammakarzinom bei 1,0 T

    Energy Technology Data Exchange (ETDEWEB)

    Sittek, H.; Perlet, C.; Kessler, M.; Reiser, M. [Institut fuer Radiologische Diagnostik, Klinikum Grossenhadern, Ludwig-Maximilians-Univ., Muenchen (Germany); Untch, M. [Klinik und Poliklinik fuer Frauenheilkunde und Geburtshilfe, Klinikum Grossenhadern, Ludwig-Maximilians-Univ., Muenchen (Germany)

    1998-12-31

    Material and Methods: We carried out 1505 MR mammographoes in 1357 patients. Biopsy was indicated in 413 cases. Among the malignancies, 23/214 (10%) were ILC. MR-M was performed with a 1.0 T whole body MRI system with a dynamic FLASH-3D sequence. Relative signal enhancement within lesions detected and morphologic pattern of contrast enhancement (mep) were determined. Three types of mep were distinguished: type 1 without contrast enhancement, type 2 with focal contrast enhancement, and type 3 with diffuse contrast enhancement of the glandular body. Results: Within MR-M alone, 19/23 (82.6%) of ILC were detected due to a mep type 2. Four ILC were false negative on MR-M (2 cases show mep type 1 or mep type 3). The sensitivity of Mx alone was 86.9% (20/23). When both Mx and MR-M were combined, all 23 ILC were detected. The addition of MR-M to Mx may increase sensitivity to about 100% in the detection of ILC. (orig.) [Deutsch] Material und Methode: Im Zeitraum 05/1993 bis 06/1996 fuehrten wir bei 1357 Patientinnen 1505 MR-Mammographien durch. In 413 Faellen wurde eine Probeexzision indiziert. Die histologische Untersuchung ergab in 214 Faellen einen malignen Tumor. Darunter befanden sich 23 ILC. Die MR-M wurden an einem 1,0 T MRT-System (Impact, Siemens, Erlangen) mit einer dynamischen FLASH 3D Sequenz durchgefuehrt. Neben dem prozentualen Anstieg der Signalintensitaet innerhalb einer Laesion haben wir fuer die Diagnostik folgende morphologische Befundmuster (BM) unterschieden: Typ 1: Keine Aufnahme, Typ 2: Fokale Aufnahme, Typ 3: Diffuse Aufnahme des Druesenkoerpers in der MR-M. Ergebnisse: Mit der MR-M konnten 19/23 (82,6%) der ILC anhand einer fokalen Zunahme der Signalintensitaet richtig positiv erkannt werden (BM Typ 2). Vier der ILC waren in der MR-M falsch negativ. In zwei Faellen (2/23) war keine Zunahme der Signalintensitaet zu verzeichnen (BM Typ 1). In zwei weiteren Faellen (2/23) maskierte eine diffuse Signalintensitaetszunahme des Druesenkoerpers (BM Typ 3

  20. Follow-up of acute myocardial infarction with Gd-DTPA-enhanced MR image

    International Nuclear Information System (INIS)

    Matheijssen, N.A.A.; Dijkman, P.; Rossum, A.C. van der; Laarse, A. van der; Voorthuisen, A. van; Bruschke, A.

    1990-01-01

    MR imaging with Gd-DTPA has been shown to be useful in the identification of acutely infarcted myocardium. The purpose of this paper is to assess the influence of Gd-DTPA on myocardial signal intensity (SI) at different intervals after acute myocardial infarction (SMI). The authors used Gd-DTPA-enhanced MR imaging to study 84 patients at different intervals after AMI. A total of 109 T1-weighted MR studies were performed with a Philips Gyroscan magnet (0.5T) before and 20 minutes after Gd-DTPA (0.15 mmol/kg given intravenously). Four groups were studied. Group 1 underwent MR imaging less than 1 week after AMI; group 2, 1-3 weeks; group 3, 3-6 weeks; and group 4, over 6 weeks after AMI

  1. Fusion of High b-valve diffusion-weighted and T2-weighted MR images improves identification of lymph nodes in the pelvis

    International Nuclear Information System (INIS)

    Mir, N.; Sohaib, S.A.; Collins, D.; Koh, D.M.

    2010-01-01

    Full text: Accurate identification of lymph nodes facilities nodal assessment by size, morphological or MR lymphographic criteria. We compared the MR detection of lymph nodes in patients with pelvic cancers using T2-weighted imaging, and fusion of diffusion-weighted imaging (OWl) and T2-weighted imaging. Twenty patients with pelvic tumours underwent 5-mm axial T2-weighted and OWl (b-values 0-750 s/mm 2 ) on a L 5T system. Fusion images of b = 750 s/mm 2 diffusion-weighted MR and T2-weighted images were created. Two radiologists evaluated in consensus the T2-weighted images and fusion images independently. For each image set, the location and diameter of pelvic nodes were recorded, and nodal visibility was scored using a 4-point scale (0-3). Nodal visualisation was compared using Relative to an Identified Distribution (RIDIT) analysis. The mean RIDIT score describes the probability that a randomly selected node will be better visualised relative to the other image set. One hundred fourteen pelvic nodes (mean 5.9 mm; 2-10 mm) were identified on T2-weighted images and 161 nodes (mean 4.3 mm; 2-10 mm) on fusion images. Using fusion images, 47 additional nodes were detected compared with T2-weighted images alone (eight external iliac, 24 inguinal, 12 obturator, two peri-rectal, one presacral). Nodes detected only on fusion images were 2-9 mm (mean 3.7 mm). Nodal visualisation was better using fusion images compared with T2-weighted images (mean RIDIT score 0.689 vs 0.302). Fusion of diffusion-weighted MR with T2-weighted images improves identification of pelvic lymph nodes compared with T2-weighted images alone. The improved nodal identification may aid treatment planning and further nodal characterisation.

  2. Bacterial Electrocatalysis of K4[Fe(CN)6] Oxidation

    DEFF Research Database (Denmark)

    Zheng, Zhiyong; Xiao, Yong; Wu, Ranran

    Shewanella oneidensis MR-1 (MR-1), a model strain of electrochemically active bacteria, can transfer electrons from cell to extracellular electron acceptors including Fe(III) (hydro)oxides. It has been reported that several redox species such as cytochromes in membranes and flavins assist...... in the electron transport (ET) processes. However, the oxidization of metal compounds was barely described. Here we report electrocatalysis of K4[Fe(CN)6] oxidation by MR-1. K4[Fe(CN)6] is a redox inorganic compound and shows a reversible redox process on bare glassy carbon (GCE). This is reflected by a pair...

  3. Extracellular polymeric substances are transient media for microbial extracellular electron transfer

    DEFF Research Database (Denmark)

    Xiao, Yong; Zhang, Enhua; Zhang, Jingdong

    2017-01-01

    in microbiology and microbial exploitation for mineral bio-respiration, pollutant conversion, and bioenergy production. We have addressed these challenges by comparing pure and EPS-depleted samples of three representative electrochemically active strains viz Gram-negative Shewanella oneidensis MR-1, Gram......-positive Bacillus sp. WS-XY1, and yeast Pichia stipites using technology from electrochemistry, spectroscopy, atomic force microscopy, and microbiology. Voltammetry discloses redox signals from cytochromes and flavins in intact MR-1 cells, whereas stronger signals from cytochromes and additional signals from both...

  4. Stress induction in the bacteria Shewanella oneidensis and Deinococcus radiodurans in response to below-background ionizing radiation.

    Science.gov (United States)

    Castillo, Hugo; Schoderbek, Donald; Dulal, Santosh; Escobar, Gabriela; Wood, Jeffrey; Nelson, Roger; Smith, Geoffrey

    2015-01-01

    The 'Linear no-threshold' (LNT) model predicts that any amount of radiation increases the risk of organisms to accumulate negative effects. Several studies at below background radiation levels (4.5-11.4 nGy h(-1)) show decreased growth rates and an increased susceptibility to oxidative stress. The purpose of our study is to obtain molecular evidence of a stress response in Shewanella oneidensis and Deinococcus radiodurans grown at a gamma dose rate of 0.16 nGy h(-1), about 400 times less than normal background radiation. Bacteria cultures were grown at a dose rate of 0.16 or 71.3 nGy h(-1) gamma irradiation. Total RNA was extracted from samples at early-exponential and stationary phases for the rt-PCR relative quantification (radiation-deprived treatment/background radiation control) of the stress-related genes katB (catalase), recA (recombinase), oxyR (oxidative stress transcriptional regulator), lexA (SOS regulon transcriptional repressor), dnaK (heat shock protein 70) and SOA0154 (putative heavy metal efflux pump). Deprivation of normal levels of radiation caused a reduction in growth of both bacterial species, accompanied by the upregulation of katB, recA, SOA0154 genes in S. oneidensis and the upregulation of dnaK in D. radiodurans. When cells were returned to background radiation levels, growth rates recovered and the stress response dissipated. Our results indicate that below-background levels of radiation inhibited growth and elicited a stress response in two species of bacteria, contrary to the LNT model prediction.

  5. Real-Time Gene Expression Profiling of Live Shewanella Oneidensis Cells

    Energy Technology Data Exchange (ETDEWEB)

    Xiaoliang Sunney Xie

    2009-03-30

    The overall objective of this proposal is to make real-time observations of gene expression in live Shewanella oneidensis cells with high sensitivity and high throughput. Gene expression, a central process to all life, is stochastic because most genes often exist in one or two copies per cell. Although the central dogma of molecular biology has been proven beyond doubt, due to insufficient sensitivity, stochastic protein production has not been visualized in real time in an individual cell at the single-molecule level. We report the first direct observation of single protein molecules as they are generated, one at a time in a single live E. coli cell, yielding quantitative information about gene expression [Science 2006; 311: 1600-1603]. We demonstrated a general strategy for live-cell single-molecule measurements: detection by localization. It is difficult to detect single fluorescence protein molecules inside cytoplasm - their fluorescence is spread by fast diffusion to the entire cell and overwhelmed by the strong autofluorescence. We achieved single-molecule sensitivity by immobilizing the fluorescence protein on the cell membrane, where the diffusion is much slowed. We learned that under the repressed condition protein molecules are produced in bursts, with each burst originating from a stochastically-transcribed single messenger RNA molecule, and that protein copy numbers in the bursts follow a geometric distribution. We also simultaneously published a paper reporting a different method using β-glactosidase as a reporter [Nature 440, 358 (2006)]. Many important proteins are expressed at low levels, inaccessible by previous proteomic techniques. Both papers allowed quantification of protein expression with unprecedented sensitivity and received overwhelming acclaim from the scientific community. The Nature paper has been identified as one of the most-cited papers in the past year [http://esi-topics.com/]. We have also an analytical framework describing the

  6. Redox sensing within the genus Shewanella

    NARCIS (Netherlands)

    Harris, Howard W.; Sánchez-Andrea, Irene; McLean, Jeffrey S.; Salas, Everett C.; Tran, William; El-Naggar, Mohamed Y.; Nealson, Kenneth H.

    2018-01-01

    A novel bacterial behavior called congregation was recently described in Shewanella oneidensis MR-1 as the accumulation of cells around insoluble electron acceptors (IEA). It is the result of a series of "run-and-reversal" events enabled by modulation of swimming speed and direction. The model

  7. Basics concepts and clinical applications of oxygen-enhanced MR imaging

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto

    2007-01-01

    Oxygen-enhanced MR imaging is a new technique, and its physiological significance has not yet been fully elucidated. This review article covers (1) the theory of oxygen enhancement and its relationship with respiratory physiology; (2) design for oxygen-enhanced MR imaging sequencing; (3) a basic study of oxygen-enhanced MR imaging in animal models and humans; (4) a clinical study of oxygen-enhanced MR imaging; and (5) a comparison of advantages and disadvantages of this technique with those of hyperpolarized noble gas MR ventilation imaging. Oxygen-enhanced MR imaging provides not only the ventilation-related, but also respiration-related information. Oxygen-enhanced MR imaging has the potential to replace nuclear medicine studies for the identification of regional pulmonary function, and many investigators are now attempting to adapt this technique for routine clinical studies. We believe that further basic studies as well as clinical applications of this new technique will define the real significance of oxygen-enhanced MR imaging for the future of pulmonary functional imaging and its usefulness for diagnostic radiology and pulmonary medicine

  8. Os acromiale: evaluation of markers for identification on sagittal and coronal oblique MR images

    Energy Technology Data Exchange (ETDEWEB)

    Uri, D.S. [University of Michigan, Dept. of Radiology, Ann Arbor, MI (United States)]|[Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia (United States); Kneeland, J.B. [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia (United States); Herzog, R. [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia (United States)

    1997-01-01

    An os acromiale is a developmental abnormality of ossification involving the anterior acromion which may contribute to impingement and rotator cuff disease. When axial MR sections do not include the acromioclavicular joint, the diagnosis of this often subtle abnormality will rest on its recognition on oblique coronal and sagittal images where it mimics the acromioclavicular joint. The identification of this anomaly is important as it frequently alters the type of surgical procedure utilized in symptomatic patients. We evaluate several imaging features which may be used to diagnose an os acromiale in these cases. (orig.). With 5 figs.

  9. Os acromiale: evaluation of markers for identification on sagittal and coronal oblique MR images

    International Nuclear Information System (INIS)

    Uri, D.S.; Kneeland, J.B.; Herzog, R.

    1997-01-01

    An os acromiale is a developmental abnormality of ossification involving the anterior acromion which may contribute to impingement and rotator cuff disease. When axial MR sections do not include the acromioclavicular joint, the diagnosis of this often subtle abnormality will rest on its recognition on oblique coronal and sagittal images where it mimics the acromioclavicular joint. The identification of this anomaly is important as it frequently alters the type of surgical procedure utilized in symptomatic patients. We evaluate several imaging features which may be used to diagnose an os acromiale in these cases. (orig.). With 5 figs

  10. Quantification of hepatic steatosis with T1-independent, T2-corrected MR imaging with spectral modeling of fat: blinded comparison with MR spectroscopy.

    Science.gov (United States)

    Meisamy, Sina; Hines, Catherine D G; Hamilton, Gavin; Sirlin, Claude B; McKenzie, Charles A; Yu, Huanzhou; Brittain, Jean H; Reeder, Scott B

    2011-03-01

    To prospectively compare an investigational version of a complex-based chemical shift-based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24-71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r(2)), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2 correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r(2

  11. Gadolinium-enhanced fat-suppression MR imaging of the female pelvis

    International Nuclear Information System (INIS)

    Shin, Joo Yong; Kim, Jung Sik; Kim, Hong

    1998-01-01

    To compare the value of Gd-DTPA enhanced, fat-suppression T1-weighted (Gd-FST1SE) MR images in the diagnosis of female pelvic disorders with that of fast spin-echo T1-weighted(T1FSE) and fast spin-echoT2-weighted(T2FSE) MR images. Materials and Methods : Pelvic MR images of 42 women (24 ovarian disorders, 19 uterine disorders) were reviewed by two radiologists. Discrimination of normal anatomic structures, identification of pathologic lesions and recognition of internal structure of the lesions such as solid and cystic portion,papillary nodule, septa and wall were evaluated using a scoring system. The Friedman two-way ANOVA test was used for data analysis. Results : T2FSE was useful for evaluation of the uterine cervix(T1/T2/Gd, 2.5/3.9/2.8,respectively), junctional zone(1.6/3.1/2.5), endometrium (2.0/3.3/3.0), ovary(1.1/2.1/1.7) and uterine myoma(1.7/2.4/2.1)(P<0.001), but secondary degeneration was best visualized on Gd-FS T1SE. The Gd-FS T1SE ;lymphadenopathy(3.4/1.5/3.7) was better visualised on this modality than on either TIFSE or T2FSE. Gd-FS T1SE images also clearly depicted papillary projection(2.4/3.1/3.8) and the solid component (2.9/3.1/3.5) of ovariancystic neoplasm(P<0.01). The confidence level in the identification of ovarian mass, internal septation and surrounding wall of cystic neoplasm was not improved on Gd-FS T1SE. Conclusion : The Gd-FS T1SE images were useful for the evaluation of metastatic lymphadenopathy in uterine cervical malignancy and for identification of the solid component and papillary projection of ovarian cystic neoplasm

  12. MR-guided discography using an open 1 Tesla MRI system

    International Nuclear Information System (INIS)

    Streitparth, Florian; Bucourt, M. de; Hamm, B.; Teichgraeber, U.; Hartwig, T.; Strube, P.; Putzier, M.; Schnackenburg, B.; Chopra, S.

    2011-01-01

    To evaluate the feasibility of MR-guided discography using an open 1 Tesla MRI system. 48 disc segments of 41 patients scheduled for intradiscal thermal treatment, total disc replacement or spondylodesis were examined. A 1.0-T open MRI was used for instrument guidance and imaging. After primary disc puncture under guidance of interactive PDw TSE imaging, 1-2 ml of gadolinium contrast saline mixture was injected into the disc. The occurrence of memory pain during injection was recorded. Axial and sagittal T1w TSE images with and without fat saturation were obtained. All MRI discograms were analysed by two readers, who were blinded to the clinical findings. Overall, the placement of the puncture needle in the targeted disc was accurate under real-time MR guidance. Injections were technically successful in all cases. No major complications occurred. The mean procedure time was 17 min (range 13-34 min). Image quality of contrast-enhanced MR discograms was excellent when using an optimized gadolinium contrast saline mixture of 1:600. Memory pain was detected in 16 out of 48 affected segments. MR-guided discography is accurate and safe. Multiplanar dynamic imaging facilitates the puncture of discs and provides high-quality MR discograms. (orig.)

  13. Structural Acoustic UXO Detection and Identification in Marine Environments

    Science.gov (United States)

    2016-05-01

    a thick steel wall, is cylindrical, and has an aspect ratio of about 5:1. Further, the interior water can support acoustic waves as does the epoxy...FINAL REPORT Structural Acoustic UXO Detection and Identification in Marine Environments SERDP Project MR-2103 MAY 2016 B. H...NUMBER Structural Acoustic UXO Detection and Identification in Marine Environments- Final report for Follow-on Work- MR-2103 Sb. GRANT NUMBER Sc

  14. Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy

    Science.gov (United States)

    Hines, Catherine D. G.; Hamilton, Gavin; Sirlin, Claude B.; McKenzie, Charles A.; Yu, Huanzhou; Brittain, Jean H.; Reeder, Scott B.

    2011-01-01

    Purpose: To prospectively compare an investigational version of a complex-based chemical shift–based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. Materials and Methods: This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24–71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r2), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2* correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Results: Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2* correction, spectral modeling of fat, and magnitude

  15. MR imaging of the ankle: Normal variants

    International Nuclear Information System (INIS)

    Noto, A.M.; Cheung, Y.; Rosenberg, Z.S.; Norman, A.; Leeds, N.E.

    1987-01-01

    Thirty asymptomatic ankles were studied with high-resolution surface coil MR imaging. The thirty ankles were reviewed for identification or normal structures. The MR appearance of the deltoid and posterior to talo-fibular ligaments, peroneous brevis and longus tendons, and posterior aspect of the tibial-talar joint demonstrated several normal variants not previously described. These should not be misinterpreted as pathologic processes. The specific findings included (1) cortical irregularity of the posterior tibial-talar joint in 27 of 30 cases which should not be mistaken for osteonecrois; (2) normal posterior talo-fibular ligament with irregular and frayed inhomogeneity, which represents a normal variant in seven of ten cases; and (3) fluid in the shared peroneal tendons sheath which may be confused for a longitudinal tendon tear in three of 30 cases. Ankle imaging with the use of MR is still a relatively new procedure. Further investigation is needed to better define normal anatomy as well as normal variants. The authors described several structures that normally present with variable MR imaging appearances. This is clinically significant in order to maintain a high sensitivity and specificity in MR imaging interpretation

  16. Silencing MR-1 attenuates inflammatory damage in mice heart induced by AngII

    International Nuclear Information System (INIS)

    Dai, Wenjian; Chen, Haiyang; Jiang, Jiandong; Kong, Weijia; Wang, Yiguang

    2010-01-01

    Myofibrillogenesis regulator-1(MR-1) can aggravate cardiac hypertrophy induced by angiotensin(Ang) II in mice through activation of NF-κB signaling pathway, and nuclear transcription factor (NF)-κB and activator protein-1(AP-1) regulate inflammatory and immune responses by increasing the expression of specific inflammatory genes in various tissues including heart. Whether inhibition of MR-1 expression will attenuate AngII-induced inflammatory injury in mice heart has not been explored. Herein, we monitored the activation of NF-κB and AP-1, together with expression of pro-inflammatory of interleukin(IL)-6, tumor necrosis factor(TNF)-α, vascular-cell adhesion molecule (VCAM)-1, platelet endothelial cell adhesion molecule (PECAM), and inflammatory cell infiltration in heart of mice which are induced firstly by AngII (PBS),then received MR-1-siRNA or control-siRNA injecting. We found that the activation of NF-κB and AP-1 was inhibited significantly, together with the decreased expression of IL-6, TNF-α, VCAM-1, and PECAM in AngII-induced mice myocardium in MR-1-siRNA injection groups compared with control-siRNA injecting groups. However, the expression level of MR-1 was not an apparent change in PBS-infused groups than in unoperation groups, and MR-1-siRNA do not affect the expression of MR-1 in PBS-infused mice. Our findings suggest that silencing MR-1 protected mice myocardium against inflammatory injury induced by AngII by suppression of pro-inflammatory transcription factors NF-κB and AP-1 signaling pathway.

  17. The value of 3D T1-weighted gradient-echo MR imaging for evaluation of the appendix during pregnancy: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi; Kim, Seong Hyun; Choi, Dongil; Lee, Soon Jin; Rhim, Hyunchul; Park, Min Jung (Depts. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)), email: kshyun@skku.edu

    2011-10-15

    Background The use of oral contrast has been essential for the identification of a normal appendix on MR imaging during pregnancy. However, stool could be used as a positive oral contrast as it is characterized by a relatively high signal on T1-weighted imaging, and 3D T1-weighted gradient-echo (T1W-GRE) MR imaging has been used to evaluate 3 mm diameter intestines in fetuses. Purpose To evaluate the added value of 3D T1W-GRE MR imaging in combination with T2-weighted imaging (T2WI) compared to T2WI alone for evaluating the appendix during pregnancy. Material and Methods Eighteen consecutive pregnant patients who were clinically suspected of having acute appendicitis underwent appendix MR imaging which included T2WI with or without spectral presaturation attenuated inversion-recovery (SPAIR) fat suppression, and 3D T1W-GRE with SPAIR fat suppression. Two radiologists reviewed the two image sets (the T2WI set and the combined set of T2WI and 3D T1W-GRE images). Pathologic and clinical results served as the reference standard. The differences in the degree of visibility of the appendix and confidence scale for diagnosing acute appendicitis between two image sets were compared by using the paired Wilcoxon signed rank test. Results For both reviewers, the degree of visibility of the appendix using the combined T2WI and 3D T1W-GRE images was significantly higher than using T2WI alone (P < 0.01), and the confidence levels for acute appendicitis using combined T2WI and 3D T1W-GRE images were significantly different from those using T2WI alone (P < 0.01). In the 13 patients with a normal appendix, both reviewers showed improved confidence levels for appendicitis using combined T2WI and 3D T1W-GRE images than T2WI alone. Conclusion Adding 3D T1W-GRE images to T2WI is helpful for identification of the appendix, as compared to T2WI alone in pregnant women without ingestion of oral contrast material. This may improve diagnostic confidence for acute appendicitis in pregnant

  18. {sup 1}H-MR spectroscopy in anorexia nervosa. Reversible cerebral metabolic changes; {sup 1}H-MR-Spektroskopie bei Anorexia nervosa: Reversible zerebrale Metabolitenaenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Moeckel, R.; Schlemmer, H.P.; Becker, G.; Koepke, J.; Georgi, M. [Heidelberg Univ. (Germany). Inst. fuer Klinische Radiologie; Gueckel, C.; Goepel, C.; Schmidt, M. [Zentralinstitut fuer Seelische Gesundheit, Mannheim (Germany). Klinik fuer Kinder- und Jugendpsychiatrie; Hentschel, F. [Zentralinstitut fuer Seelische Gesundheit, Mannheim (Germany). Neuroradiologie

    1999-04-01

    Purpose: By using localized {sup 1}H-MR spectroscopy in the brain of patients with anorexia nervosa we wanted to verify our preliminary results and to look for a reversibility of the metabolic changes under therapy. Methods: In 22 patients and 17 healthy volunteers (11 follow-up examinations) single voxel {sup 1}H-MR spectroscopy (TE=50 ms, TM=30 ms, TR=1500 ms, voxel (2 cm){sup 3}, acq.: 256) was used in two different localizations (thalamus and parieto-occipital region). The first examination of the patients was performed before therapy, the follow-up examination at the end of therapy. Results: In both regions of the brain we found a statistically significant elevation of the Cho/Cr-ratio in comparison to normal controls. The follow-up examinations revealed reversibility of the metabolic changes under successful therapy. Conclusion: {sup 1}H-MR spectroscopy reveals metabolic changes in the brain of patients with anorexia nervosa, which are reversible under successful therapy. These metabolic changes can be conclusively explained using a biochemical model. (orig.) [Deutsch] Ziel: Im Rahmen dieser weiterfuehrenden Studie sollten die bisherigen Ergebnisse der lokalisierten {sup 1}H-MR-Spektroskopie des Gehirns an Patienten mit Anorexia nervosa verifiziert werden. Weiter sollte ueberprueft werden, ob die von uns nachgewiesenen metabolischen Veraenderungen unter Therapie reversibel sind. Methode: Die {sup 1}H-MR-Spektren wurden bei 22 Patientinnen und 17 Probanden (11 Verlaufskontrollen) in Einzelvolumentechnik (TE=50 ms, TM=30 ms, TR=1500 ms, Voxel: (2 cm){sup 3}, Acq.: 256) in zwei unterschiedlichen Hirnregionen (Thalamus, parieto-okzipitale Region) durchgefuehrt. Die erste Untersuchung der Patienten erfolgte bei Aufnahme und die Verlaufskontrolle zum Abschluss der stationaeren Behandlung. Ergebnisse: Bei den Patienten wurde in beiden Hirnregionen ein statistisch signifikant erhoehter Wert fuer das Cho/Cr-Verhaeltnis im Vergleich zu dem Normalkollektiv nachgewiesen

  19. Knowledge-based interpretation of cranial MR images

    International Nuclear Information System (INIS)

    Kuhn, M.H.; Menhardt, W.; Schmidt, K.H.

    1987-01-01

    A computerized system is described that can be used to evaluate an MR tomogram automatically to support clinical identification of anatomic and pathologic structures and to aid in planning MR measurements. Knowledge from three domains is used for the interpretation of an MR image: nosologic knowledge, knowledge of MR imaging parameters, and anatomic and morphologic knowledge. Nosologic information is used to generate hypotheses about possible pathologies and their locations, based on the signs and symptoms of the patient. With this information, a sequence of interpretation modules, each able to detect substructures in already detected structures with the aid of techniques from image processing, pattern recognition, and artificial intelligence, is generated and executed

  20. [MR implant labelling and its use in clinical MRI practice].

    Science.gov (United States)

    Mühlenweg, M; Schaefers, G

    2015-08-01

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application.

  1. MR implant labelling and its use in clinical MRI practice

    International Nuclear Information System (INIS)

    Muehlenweg, M.; Schaefers, G.

    2015-01-01

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application. (orig.) [de

  2. Quantification of dextrose in model solution by 1H MR spectroscopy at 1.5T

    International Nuclear Information System (INIS)

    Lee, Kyung Hee; Cho, Soon Gu; Kim, Hyung Jin; Suh, Chang Hae; Kim, Yong Seong; Lee, Jung Hee

    2002-01-01

    To evaluate the feasibility of proton magnetic resonance spectroscopy ( 1 H-MRS) using a 1.5T magnetic resonance (MR) imager for quantification of the contents of model solutions. We prepared model solutions of dextrose +water and dextrose +water + ethanol at dextrose concentrations of 0.01% to 50% and 0.01% to 20%, respectively. Using these solutions and a 1.5T MR imager together with a high-resolution nuclear magnetic resonance (NMR) spectroscope, we calculated the ratios of dextrose to water peak, (dextrose +ethanol) to water peak, and (dextrose + ethanol) to ethanol peak, as seen on MR and NMR spectra, analysing the relationships between dextrose concentration and the ratios of peaks, and between the ratios of the peaks seen on MR spectra and those seen on NMR spectra. Changes in the ratios between dextrose concentration and dextrose to water peak, (dextrose + ethanol) to water peak and (dextrose + ethanol) to ethanol peak, as seen on MR spectra, were statistically significant, and there was good linear regression. There was also close correlation between the ratios of the observed on MR and NMR spectra. The results depict the quantification of dextrose concentration according to the ratios of spectral peaks obtained by proton MRS at 1.5T. Using proton MRS at 1.5T, and on the basis of the ratios of spectcal peaks, it was possible to quantify the concentration of dextrose in model solutions of dextrose + water and dextrose + water+ ethanol. The results of this study suggest that for quantifying the contents of biofluids, the use of low-tesla 1 H-MRS is feasible

  3. Identification of chronic thromboembolic pulmonary hypertension with MR imaging

    International Nuclear Information System (INIS)

    Gefter, W.B.; Palevsky, H.I.; Dinsmore, B.J.; Reichek, N.; DeRoos, A.; Kressel, H.Y.

    1988-01-01

    Thromboembolic pulmonary hypertension (TE-PHT) may be treatable by thromboendarterectomy. To evaluate the role of MR imaging in TE-PHT, the authors imaged eight patients with primary pulmonary hypertension or ASDs and seven patients with TE-PHT. Patients underwent conventional spin-echo (SE) imaging; three of seven patients with TE-PHT and eight of eight without emboli underwent cine MR studies. TE-PHT findings included focal areas of vessel wall thickening or plaquelike lesions in the central pulmonary arteries in six of seven. (Thrombus was not distinguished from flow-related signal in the seventh patient). Studies performed on three patients after thromboendarterectomy showed significant resolution of vascular lesions. Patients without emboli showed dilated central vessels without focal wall or lumen abnormality. Cine studies differentiated flow-related signal from thrombus, but wall thickening was better appreciated on SE images. MR imaging appears useful in identifying patients with TE-PHT who may benefit from surgery

  4. Cochlear anatomy: CT and MR imaging

    International Nuclear Information System (INIS)

    Martinez, Manuel; Bruno, Claudio; Martin, Eduardo; Canale, Nancy; De Luca, Laura; Spina, Juan C. h

    2002-01-01

    The authors present a brief overview of the normal cochlear anatomy with CT and MR images in order to allow a more complete identification of the pathological findings in patients with perceptive hipoacusia. (author)

  5. Fire-related post-traumatic stress disorder: brain 1H-MR spetroscopic findings

    International Nuclear Information System (INIS)

    Lim, Myung Kwan; Suh, Chang Hae; Kim, Hyung Jin; Kim, Sung Tae; Lee, Jeong Seop; Kang, Min Hee; Kim, Ji Hye; Lee, Jung Hee

    2003-01-01

    To investigate the MR imaging and 1 H-MR spectroscopic findings of acute fire-related post-traumatic stress disorder (PTSD). Sixteen patients (M:F=10:6; mean age, 16 years) with fire-related PTSD underwent MR imagine and 1 H-MR spectroscopy, and for control purposes, the procedures were repeated in eight age-matched normal volunteers. In all patients and controls, the regions of interest where data were acquired at MRS were the basal ganglia (BG), frontal periventricular white matter (FWM), and parietal periventricular white matter (PWM). In all patients with PTSD, MR images appeared normal. In contrast, MRS showed that in the BG, NAA/Cr ratios were significantly lower in patients than in volunteers. This decrease did not, however, show close correlation with the severity of the neuropsychiatric symptoms. In patients, neither NAA/Cr ratios in FWM nor PWM, nor Cho/Cr ratios in all three regions, were significantly different from those in the control group. Decreased NAA/Cr ratios in the BG, as seen at 1 H-MRS, might be an early sign of acute fire-related PTSD

  6. In vivo proton MR spectroscopy of canine status epilepticus

    International Nuclear Information System (INIS)

    Sandstrom, J.C.; Partington, C.R.; Perman, W.H.

    1988-01-01

    Invasive studies of rodent seizure models have demonstrated twice-normal lactate accumulation at the seizure focus. The authors investigated metabolic changes in canine kainic acid-induced seizures by means of in vivo volume-selective water-suppressed proton MR spectroscopy (MVSTE pulse sequence). Spectra from several experiments are presented demonstrating changes in lactate and MR imaging-visible lipid concentration. Spectra were obtained with interlaced acquisition from the brain and an external standard for relative quantification, with best-case line width of 4 Hz and typical line widths of 7-15 Hz at 1.5 T. Direct injection of NAA and lactate in the brain allowed in vivo identification of resonances

  7. Characterization of a prototype MR-compatible Delta4 QA system in a 1.5 tesla MR-linac

    Science.gov (United States)

    de Vries, J. H. W.; Seravalli, E.; Houweling, A. C.; Woodings, S. J.; van Rooij, R.; Wolthaus, J. W. H.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2018-01-01

    To perform patient plan quality assurance (QA) on a newly installed MR-linac (MRL) it is necessary to have an MR-compatible QA device. An MR compatible device (MR-Delta4) has been developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response, such as short-term reproducibility, dose linearity, field size dependency, dose rate dependency, dose-per-pulse dependency and angular dependency, were investigated for the clinical Delta4-PT as well as for the MR compatible version. All tests were performed with both devices on a conventional linac and the MR compatible device was tested on the MRL as well. No statistically significant differences were found in the short-term reproducibility (tesla magnetic field of the Elekta MR-linac

  8. Biotic-Abiotic Nanoscale Interactions in Biological Fuel Cells

    Science.gov (United States)

    2014-03-28

    oneidensis MR-1 bacterial nanowires are lipid-based extensions of the outer- membrane and periplasmic electron transport proteins, Science Magazine ...Minnesota Biotechnology Institute Seminar 2013 California State University, Long Beach Physics Colloquium 2014 Okayama University, Japan. Mini...Investigator Program Award 2012 Selected by Popular Science Magazine as one of the “Brilliant 10” of 2012 2013 USC Dornsife Raubenheimer award for

  9. Bioremediation of nanomaterials

    Science.gov (United States)

    Chen, Frank Fanqing; Keasling, Jay D; Tang, Yinjie J

    2013-05-14

    The present invention provides a method comprising the use of microorganisms for nanotoxicity study and bioremediation. In some embodiment, the microorganisms are bacterial organisms such as Gram negative bacteria, which are used as model organisms to study the nanotoxicity of the fullerene compounds: E. coli W3110, a human related enterobacterium and Shewanella oneidensis MR-1, an environmentally important bacterium with versatile metabolism.

  10. Characterization of a prototype MR-compatible Delta4 QA-system in a 1.5 tesla MR-linac

    NARCIS (Netherlands)

    de Vries, Wilfred J H; Seravalli, Enrica; Houweling, Anette; Woodings, Simon J; van Rooij, Rob; Wolthaus, Jochem W H; Lagendijk, JJW; Raaymakers, Bas W

    2018-01-01

    To perform patient plan-quality assurance (QA) on the newly installed MR-Linac (MRL) there was a need for having an MR-compatible QA-device. An MR compatible device (MR-Delta4) was developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response

  11. North American International Society for Microbial Electrochemical Technologies Meeting (Abstracts)

    Science.gov (United States)

    2016-04-18

    electrode interface in Shewanella oneidensis MR-1 Catarina Paquete1, Bruno Fonseca1, Ricardo O. Louro1 1 Instituto de Tecnologia Química e Biológica...response to anodic pH variation in a dual chamber microbial fuel cell Valentina Margaria, Instituto Italiano di Tecnologia , Italy 2-15 Microbial...SnO2 nanostructured composite for cathode oxygen reduction reaction in microbial fuel cells Adriano Sacco, Instituto Italiano di Tecnologia , Italy 2

  12. MR plaque imaging of the carotid artery

    International Nuclear Information System (INIS)

    Watanabe, Yuji; Nagayama, Masako

    2010-01-01

    Atherosclerotic carotid plaque represents a major cause of cerebral ischemia. The detection of vulnerable plaque is important for preventing future cardiovascular events. The key factors in advanced plaque that are most likely to lead to patient complications are the condition of the fibrous cap, the size of the necrotic core and hemorrhage, and the extent of inflammatory activity within the plaque. Magnetic resonance (MR) imaging has excellent soft tissue contrast and can allow for a more accurate and objective estimation of carotid wall morphology and plaque composition. Recent advances in MR imaging techniques have permitted serial monitoring of atherosclerotic disease evolution and the identification of intraplaque risk factors for accelerated progression. The purpose of this review article is to review the current state of techniques of carotid wall MR imaging and the characterization of plaque components and surface morphology with MR imaging, and to describe the clinical practice of carotid wall MR imaging for the determination of treatment plan. (orig.)

  13. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    International Nuclear Information System (INIS)

    Law, M; Yuan, J; Wong, O; Yu, S

    2016-01-01

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck

  14. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Law, M; Yuan, J; Wong, O; Yu, S [Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong (Hong Kong)

    2016-06-15

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck

  15. MR imaging identification of white-matter lesions in uncomplicated chronic alcoholism

    International Nuclear Information System (INIS)

    Gallucci, M.; Amicarelli, I.; DiCesare, E.; Rossi, A.; Stratta, P.; Casacchia, M.; Passariello, R.

    1987-01-01

    Chronic alcoholics may have central nervous system (CNS) lesions, such as microvasculitis, or glial, neural, and myelinic degeneration, as has been documented in postmortem studies on patients with Wernicke disease, corpus callosum degeneration, or central pontine myelinolisis. The presence of early white matter diseases can aslo be projected in patients not suffering the neurologic complications of alcoholism. Thirty-five alcoholics (DSM-III criteria) and 35 healthy controls underwent MR imaging at 0.5 T (repetition time/echo time = 1,800/30-120 msec). Subjects older than 60 years or who had CNS injuries or clinically evident hepatopathies were excluded. Besides the aspecific corticosubcortical and cerebellar atrophy, MR imaging disclosed multiple round hyperintense areas in the white matter of 14 patients but in none of the healthy controls. These results suggest early involvement of the brain in chronic alcoholism

  16. High-resolution MR imaging of the elbow using a microscopy surface coil and a clinical 1.5 T MR machine: preliminary results

    International Nuclear Information System (INIS)

    Yoshioka, Hiroshi; Ueno, Teruko; Takahashi, Nobuyuki; Saida, Yukihisa; Tanaka, Toshikazu; Kujiraoka, Yuka; Shindo, Masashi; Nishiura, Yasumasa; Ochiai, Naoyuki

    2004-01-01

    To obtain high-resolution MR images of the elbow using a microscopy surface coil with a 1.5 T clinical machine and to evaluate the feasibility of its use for elbow injuries. Five asymptomatic normal volunteers and 13 patients with elbow pain were prospectively studied with MR imaging using a microscopy surface coil 47 mm in diameter. High-resolution MR images using a microscopy coil were obtained with fast spin echo (FSE) proton density-weighted sequence, gradient recalled echo (GRE) T2*-weighted sequence, and short tau inversion recovery (STIR) sequence, with a 1-2 mm slice thickness, a 50-70 mm field of view, an imaging matrix of 140-224 x 512 using zero fill interpolation, and 2-6 excitations. High-resolution MR images of normal volunteers using a microscopy coil clearly showed each structure of the medial and lateral collateral ligaments on GRE T2*-weighted images and FSE proton-density weighted images. Partial medial collateral ligament injury, a small avulsion of the medial epicondyle, and osteochondritis dissecans were well demonstrated on high-resolution MR images. High-resolution MR imaging of the elbow using a microscopy surface coil with a 1.5 T clinical machine is a promising method for accurately characterizing the normal anatomy of the elbow and depicting its lesions in detail. (orig.)

  17. MR implant labelling and its use in clinical MRI practice; MR-Implantatkennzeichnungen und ihre Anwendung in der klinischen MRT-Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenweg, M. [Krankenhaus Martha-Maria Halle-Doelau, Institut fuer Radiologie, Halle (Saale) (Germany); Schaefers, G. [MR:comp GmbH, Gelsenkirchen (Germany)

    2015-08-15

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application. (orig.) [German] Implantate in Patienten muessen vor einer MR-Untersuchung auf MR-Sicherheit abgeklaert werden, um moegliche z. T. schwere Verletzungen und Implantatfehlfunktionen in einer MR-Umgebung weitestgehend auszuschliessen. Es gilt unveraendert die generelle Kontraindikation von

  18. The MR imaging features of the posterior intermalleolar ligament in patients with posterior impingement syndrome of the ankle

    International Nuclear Information System (INIS)

    Fiorella, D.

    1999-01-01

    Objective. To describe the MR imaging features of the posterior intermalleolar ligament (IML) in patients with posterior impingement syndrome (PIS) of the ankle.Design and patients. Three patients (one male and two females, 13-25 years of age) are presented. Each patient presented clinically with symptoms of PIS of the ankle. Plain film examination was negative for a structural cause of the PIS in all patients. MR images were obtained with a 1.5 T scanner using an extremity coil. Clinical data and, in one patient, findings at ankle arthroscopy, were correlated with the results of MR imaging.Results. Ankle MR images from the three patients with a clinical diagnosis of PIS are presented. Findings in all patients included: (1) absence of another structural cause of the PIS (i.e., an os trigonum, trigonal process, fracture, loose bodies, etc.), (2) identification of the IML as a structure discrete from the posterior talofibular and tibiofibular ligaments, and (3) prominence of the IML as indicated by (a) identification of the IML in three different imaging planes, and (b) a caliber of the IML comparable to that of the conventional posterior ankle ligaments visualized in the same imaging plane. Arthroscopic resection of a meniscoid IML resulted in resolution of the PIS in one of the patients presented.Conclusions. MR imaging is an effective means of investigating the IML as a potential cause of PIS. The identification of a prominent IML in the absence of another structural cause of PIS indicates that impingement of the IML is the most likely cause of PIS. (orig.)

  19. The MR imaging features of the posterior intermalleolar ligament in patients with posterior impingement syndrome of the ankle

    Energy Technology Data Exchange (ETDEWEB)

    Fiorella, D. [Duke Univ. Medical Center, Durham, NC (United States). Dept. of Radiology; Duke Univ., Durham, NC (United States). Medical Center; Helms, C.A. [Duke Univ. Medical Center, Durham, NC (United States). Dept. of Radiology; Nunley, J.A. II [Dept. of Orthopedic Surgery, Duke University Medical Center, Durham, NC (United States)

    1999-10-01

    Objective. To describe the MR imaging features of the posterior intermalleolar ligament (IML) in patients with posterior impingement syndrome (PIS) of the ankle.Design and patients. Three patients (one male and two females, 13-25 years of age) are presented. Each patient presented clinically with symptoms of PIS of the ankle. Plain film examination was negative for a structural cause of the PIS in all patients. MR images were obtained with a 1.5 T scanner using an extremity coil. Clinical data and, in one patient, findings at ankle arthroscopy, were correlated with the results of MR imaging.Results. Ankle MR images from the three patients with a clinical diagnosis of PIS are presented. Findings in all patients included: (1) absence of another structural cause of the PIS (i.e., an os trigonum, trigonal process, fracture, loose bodies, etc.), (2) identification of the IML as a structure discrete from the posterior talofibular and tibiofibular ligaments, and (3) prominence of the IML as indicated by (a) identification of the IML in three different imaging planes, and (b) a caliber of the IML comparable to that of the conventional posterior ankle ligaments visualized in the same imaging plane. Arthroscopic resection of a meniscoid IML resulted in resolution of the PIS in one of the patients presented.Conclusions. MR imaging is an effective means of investigating the IML as a potential cause of PIS. The identification of a prominent IML in the absence of another structural cause of PIS indicates that impingement of the IML is the most likely cause of PIS. (orig.)

  20. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  1. In-situ growth of graphene/polyaniline for synergistic improvement of extracellular electron transfer in bioelectrochemical systems.

    Science.gov (United States)

    Sun, De-Zhen; Yu, Yang-Yang; Xie, Rong-Rong; Zhang, Chun-Lian; Yang, Yuan; Zhai, Dan-Dan; Yang, Guodong; Liu, Lei; Yong, Yang-Chun

    2017-01-15

    Graphene composite has been widely used in various bioelectrochemical systems (BES). However, it is suffered from tedious fabrication procedure and ambiguous mechanism for its effect on BES. Here, a one-step and in-situ strategy for simultaneously graphene exfoliation and aniline polymerization was developed for fabrication of graphene/PANI composite electrode (GO/PANI OS ). This GO/PANI OS outperformed graphite paper (GP), GP with PANI (GP/PANI) and GP with electrochemical exfoliated graphene (GO H2SO4 ) in Shewanella oneidensis MR-1 inoculated BES (improved the power density output, i.e., 24, 3.4 and 5.7 times of GP , GP/PANI and GO H2SO4 , respectively). Further analysis revealed a synergistic improvement on both direct and mediated extracellular electron transfer of S. oneidensis MR-1 by GO/PANI OS contributed to its performance enhancement in BES. This work not only provided a simple strategy for graphene composite fabrication, but also unveiled the underlying mechanism for its stimulation on BES, which promises new opportunity of graphene composite application in various biosystems. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Mr imaging and mr spectroscopy of brain metastases by mr perfusion

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Lichy, M.P.; Thilmann, C.; Guenther, M.; Bachert, P.; Delorme, S.; Schad, L.R.; Debus, J.; Schlemmer, H.P.; Maudsley, A.A.

    2003-01-01

    In follow-up examinations of irradiated brain metastases conventional contrast-enhanced morphological MR imaging is often unable to distinguish between transient radiation effects, radionecrosis, and tumor recurrence. To evaluate changes of relative cerebral blood flow (rCBF) in irradiated brain metastases arterial spin-labeling techniques (ASL) were applied and compared to the outcome of 1 H MR spectroscopy and spectroscopic imaging ( 1 H MRS, SI). Patients and methods In 2 patients follow-up examinations of irradiated brain metastases were performed on a 1.5-T tomograph (average single dose: 20 Gy/80% isodose). Relative CBF values of gray matter (GM), white matter (WM), and metastases (Met) were measured by means of the ASL techniques ITS-FAIR and Q2TIPS. 1 H MRS was performed with PRESS 1500/135. In both patients with initially hyperperfused metastases (Met/GM >1) the reduction of rCBF after stereotactic radiosurgery indicated response to treatment - even if the contrast-enhancing region increased - while increasing rCBF values indicated tumor progression. The findings were confirmed by 1 H MRS, SI and subsequent follow-up. The ASL techniques ITS-FAIR and Q2TIPS are able to monitor changes of rCBF in irradiated brain metastases. The two cases imply a possible role for ASL-MR perfusion imaging and 1 H MR spectroscopy in differentiating radiation effects from tumor progression. (orig.) [de

  3. MR cholangiopancreatography. Comparison of images obtained with 1.0 and 1.5 tesla units

    International Nuclear Information System (INIS)

    Yasui, Masayasu; Ito, Katsuyoshi; Koike, Shinji; Matsunaga, Naofumi

    2002-01-01

    The purpose of this study was to compare the image quality and visualization obtained in MR cholangiopancreatography (MRCP) using different high-field strength (1.0 vs. 1.5 Tesla) MR units and to assess the effect of field strength on MRCP. This study population included 10 healthy volunteers and 37 patients suspected of having pancreatobiliary diseases. MRCP images were obtained using two MR units with different high-field strengths (1.0 and 1.5 Tesla), with half-Fourier acquisition single-shot turbo spin-echo (HASTE) and rapid acquisition by relaxation enhancement (RARE) sequences. The image quality and visualization of each portion of the pancreatobiliary system were graded and recorded using a four-point scale. Additionally, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. The SNR and CNR in HASTE sequences acquired with the 1.5 Tesla (T) unit were significantly higher than those acquired with the 1.0 T unit (p=0.001). In qualitative analysis, there were no statistically significant differences in image quality or visualization of the ducts in either HASTE or RARE sequences between 1.0 T and 1.5 T. Our study showed that visual image quality provided by MRCP was equivalent at 1.0 and 1.5 T. (author)

  4. Fire-related post-traumatic stress disorder: brain {sup 1}H-MR spetroscopic findings

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Myung Kwan; Suh, Chang Hae; Kim, Hyung Jin; Kim, Sung Tae; Lee, Jeong Seop; Kang, Min Hee [Inha University Hospital College of Medicine, Incheon (Korea, Republic of); Kim, Ji Hye [Gachon Medical School, Incheon (Korea, Republic of); Lee, Jung Hee [National Institute of Neurologic Disorders and Stroke, Bethesda (United States)

    2003-06-01

    To investigate the MR imaging and {sup 1}H-MR spectroscopic findings of acute fire-related post-traumatic stress disorder (PTSD). Sixteen patients (M:F=10:6; mean age, 16 years) with fire-related PTSD underwent MR imagine and {sup 1}H-MR spectroscopy, and for control purposes, the procedures were repeated in eight age-matched normal volunteers. In all patients and controls, the regions of interest where data were acquired at MRS were the basal ganglia (BG), frontal periventricular white matter (FWM), and parietal periventricular white matter (PWM). In all patients with PTSD, MR images appeared normal. In contrast, MRS showed that in the BG, NAA/Cr ratios were significantly lower in patients than in volunteers. This decrease did not, however, show close correlation with the severity of the neuropsychiatric symptoms. In patients, neither NAA/Cr ratios in FWM nor PWM, nor Cho/Cr ratios in all three regions, were significantly different from those in the control group. Decreased NAA/Cr ratios in the BG, as seen at {sup 1}H-MRS, might be an early sign of acute fire-related PTSD.

  5. Comprehensive MR imaging of acute gynecologic diseases.

    Science.gov (United States)

    Dohke, M; Watanabe, Y; Okumura, A; Amoh, Y; Hayashi, T; Yoshizako, T; Yasui, M; Nakashita, S; Nakanishi, J; Dodo, Y

    2000-01-01

    Rapid advances in techniques of magnetic resonance (MR) imaging have enabled diagnosis of acute gynecologic conditions, which are characterized by sudden onset of lower abdominal pain, fever, genital bleeding, intraperitoneal bleeding, or symptoms of shock. The chemical-selective fat-suppression technique not only helps establish the characteristics of lesions that contain fat components but also increases the conspicuity of inflammatory lesions. When a T2-weighted image is obtained with a very long effective echo time (>250 msec), even a small amount of ascites can be easily identified and the contrast between urine and complex fluid becomes more conspicuous. T2*-weighted images are useful for identification of hemorrhagic lesions by demonstrating deoxyhemoglobin and hemosiderin. Contrast material-enhanced dynamic subtraction MR imaging performed with a three-dimensional fast field-echo sequence and a rapid bolus injection of gadopentetate dimeglumine allows evaluation of lesion vascularity and the anatomic relationship between pelvic vessels and a lesion and allows identification of the bleeding point by demonstrating extravasation of contrast material. To optimize the MR imaging examination, attention should be given to the parameters of each pulse sequence and proper combination of the sequences.

  6. Targeted Ultrasound for MR-Detected Lesions in Breast Cancer Patients

    International Nuclear Information System (INIS)

    Shin, Jung Hee; Han, Boo Kyung; Choe, Yeon Hyeon; Ko, Kyung Ran; Choi, Nami

    2007-01-01

    To investigate the usefulness of targeted ultrasound (US) in the identification of additional suspicious lesions found by magnetic resonance (MR) imaging in breast cancer patients and the changes in treatment based on the identification of the lesions by the use of targeted US. One-hundred forty nine patients who underwent breast MR imaging for a preoperative evaluation of breast cancer between January 2002 and July 2004 were included in the study. We searched all cases for any additional lesions that were found initially by MR imaging and investigated the performance of targeted US in identifying the lesions. We also investigated their pathological outcomes and changes in treatment as a result of lesion identification. Of the 149 patients with breast cancer, additional suspicious lesions were detected with MR imaging in 62 patients (42%). Of the 69 additional lesions found in those 62 patients, 26 (38%) were confirmed as cancers by histology. Thirty-eight lesions in 31 patients were examined with targeted US and were histologically revealed as cancers in 18 (47%), high risk lesions in two (5%), benign lesions in 15 (39%), and unidentified lesions in three (8%). The cancer rate was statistically higher in lesions with a US correlate than in lesions without a US correlate (p = 0.028). Of 31 patients, the surgical plan was altered in 27 (87%). The use of targeted US justified a change in treatment for 22 patients (81%) and misled five patients (19%) into having an unnecessary surgical excision. Targeted US can play a useful role in the evaluation of additional suspicious lesions detected by MR imaging in breast cancer patients, but is limited in lesions without a US correlate

  7. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    International Nuclear Information System (INIS)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R.; Aarsvold, John N.; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with ["1"1C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  8. Bone marrow MR imaging findings in disuse osteoporosis

    International Nuclear Information System (INIS)

    Abreu, Marcelo R. de; Wesselly, Michelle; Chung, Christine B.; Resnick, Donald

    2011-01-01

    To demonstrate MR imaging findings in the cortical and trabecular bone as well as marrow changes in patients with disuse osteoporosis (DO). Sixteen patients (14 men, 2 women, aged 27-86 years) with clinical and radiographic evidence of DO of a lower limb joint (10 knees, 6 ankles) with MR examination of the same joint performed within a 1-month period were selected, as well as 16 healthy volunteers (7 men, 9 women, aged 25-75 years, 10 knees and 6 ankles). MR imaging findings of the bone marrow were analyzed by 2 musculoskeletal radiologists in consensus regarding: diffuse or focal signal alteration, reinforcement of vertical or longitudinal trabecular lines, and presence of abnormal vascularization. All patients (100%,16/16) with DO presented MR imaging abnormalities of the bone marrow, such as: accentuation of vertical trabecular lines (50%, 8/16), presence of subchondral lobules of fat (37.5%, 6/16), presence of horizontal trabecular lines (31%, 5/16), prominence of bone vessels (25%, 4/16), and presence of dotted areas of high signal intensity on T2-weighted fat-suppressed sequences (12.5%, 2/16). Such MR findings did not appear in the control individuals. There are several MR imaging findings in bones with DO that range from accentuation of vertical and horizontal marrow lines, presence of subchondral lobules of fat, prominent bone vascularization and the presence of dotted foci of high signal intensity on T2-weighted fat-suppressed sequences. Recognition of these signs may prove helpful in the identification of DO as well as distinguishing these findings from other entities. (orig.)

  9. Ankle ligamints : comparison of MR arthrography with conventional MR imaging in amputated feet

    International Nuclear Information System (INIS)

    Yoo, Jae Sung; Lee, Sang Yong; Lee, Jeong Min; Han, Young Min; Chung, Kyung Ho; Kim, CHong Soo

    2001-01-01

    To compare magnetic resonance (MR) arthrography with conventional MR imaging in the evaluation of ankle ligaments. Eight freshly amputated human feet underwent conventional MR imaging and MR arthrography. For the former, 1.5-T magnets in the axial, coronal and sagittal planes were used, and T1-weighted sequences were obtained. Following the injection of 6-10 ml of diluted contrast media (Gd-DTPA 1:250), T1-weighted images were obtained in the same positions as conventional MR images. Paired conventional MR imaging and MR arthrography of each ankle ligament were rated on a five-point scale, and to reflect inter-group differences a Wilcoxon singed-rank test was used to compare the different measurements (p<0.05). In two ankles, MR images of the ligaments were correlated with ankle dissection. Anterior and posterior talofibular ligaments were more clearly revealed by MR arthrography than by conventional MR imaging, while calcaneofibular ligaments showed no difference between these two modalities. With regard to deltoid ligaments, visualization of the anterior and posterior tibiotalar ligament was much improved when contrast material was used to outline the ligament's articular aspect. Visualization of the posterior inferior tibiofibular ligament and inferior transverse ligament were also improved when the use of contrast material provided delineation of the articular side of the ligaments and separated them from adjacent bone. In addition, MR arthography was very useful for indentification of the posterior intermalleolar ligament, though its use did not enhance visualization of the calcaneofibular, tibiocalcaneal, spring or tibiospring ligaments. MR arthrography accurately revealed the anatomic details of ankle ligaments, and may therefore be more useful than conventional Mr imaging for evaluation of these structures

  10. Appearance of normal brain maturation on 1.5-T MR images

    International Nuclear Information System (INIS)

    Barkovich, A.J.; Kjos, B.; Jackson, D.E. Jr.; Norman, D.

    1987-01-01

    To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weighted images than on T2-weighted images, possibly because of T1 shortening by the components of the developing myelin sheaths. The later changes on the T2-weighted images correlated best with the development of myelination, as demonstrated by histochemical methods. T1-weighted images were most useful to monitor normal brain development in the first 6 to 8 months of life; T2-weighted images were more useful after 6 months. The milestones in the MR appearance of normal maturation of the brain are presented. The milestones in the MR appearance of normal maturation of the brain are presented. Persistent areas of long T2 relaxation times are seen superior and dorsal to the ventricular trigone in all infants examined and should not be mistaken for ischemic change

  11. MR angiography, MR imaging and proton MR spectroscopy in-vivo assessment of skeletal muscle ischemia in diabetic rats.

    Directory of Open Access Journals (Sweden)

    Stefano Delli Pizzi

    Full Text Available To prospectively evaluate the feasibility of using magnetic resonance (MR techniques for in-vivo assessing a rat diabetic model of limb ischemia. Unilateral hind limb ischemia was induced by ligation of the iliac-femoral artery in male streptozotocin-treated and non-diabetic control rats. Four weeks after ligation, rats underwent MR Angiography (MRA, T(1-weighted and Short Time Inversion Recovery (STIR sequences and muscle Proton MR Spectroscopy ((1H-MRS on both hind limbs. After MR examinations, immunoblotting and immunofluorescence analysis were performed. MRA showed a signal void due to flow discontinuation distal to the artery ligation. T(1-weighted and STIR images showed, respectively, the presence of tissue swelling (p = 0.018 for non-diabetic; p = 0.027 for diabetic rats and signal hyperintensity in tissue affected by occlusion. Mean total creatine/water for the occluded limb was significantly lower than for the non-occluded limbs in both non-diabetic (5.46×10(-4 vs 1.14×10(-3, p = 0.028 and diabetic rats (1.37×10(-4 vs 1.10×10(-3; p = 0.018. MR Imaging and (1H-MRS changes were more pronounced in diabetic than in non-diabetic occluded limbs (p = 0.032. MR findings were confirmed by using histological findings. Combined MR techniques can be used to demonstrate the presence of structural and metabolic changes produced by iliac-femoral artery occlusion in rat diabetic model of limb ischemia.

  12. MR-based source localization for MR-guided HDR brachytherapy

    Science.gov (United States)

    Beld, E.; Moerland, M. A.; Zijlstra, F.; Viergever, M. A.; Lagendijk, J. J. W.; Seevinck, P. R.

    2018-04-01

    For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.

  13. Design and Construction Rules for Mechanical components of FBR nuclear islands: RCC-MR. Tome 1, Volume H: Supports

    International Nuclear Information System (INIS)

    1985-06-01

    The present book is the fifth one of a whole set of 12 which constitute the present edition of the RCC-MR. The volume H applies to supports of equipments when these equipments are concerned by the RCC-MR rules in application of the chapter RA 4000 of the Tome 1, Vol A. One defines the field of application of this volume and the classification rules of supports in two levels. One defines the different types of supports and fasteners, as also the classification of the support elements in primary or resistance (or structure) elements and secondary (stability) elements. One defines the documents to be established for the components and their constitutive elements, the modalities of identification of pieces and welded joints, the rules to choose the materials of the support elements, the rules to follow for the support conception, the rules to follow for fabrication and tests, as also other rules than those given in the chapters RH 2000 to RH 4000, to homologate a standard support or a component of a standard support [fr

  14. Adult tibial intercondylar eminence fracture: evaluation with MR imaging

    International Nuclear Information System (INIS)

    Toye, Leon R.; Cummings, Dean P.; Armendariz, Gus

    2002-01-01

    Tibial intercondylar eminence (TIE) fractures are well described in the pediatric orthopedic literature. Adult TIEs are much less common, and limited literature exists on the subject. Adult knee hyperextension injuries commonly result in anterior cruciate ligament (ACL) injury; however, with significant trauma, a TIE enters the differential diagnosis. Identification and classification of TIE fractures typically has been provided by radiography. The incidence of concomitant injuries with magnetic resonance (MR) imaging in patients with adult TIE fractures has not been determined. We present a case of an adult type III TIE fracture seen on radiography that only with further MR imaging revealed a concomitant lateral tibial plateau fracture. Utilization of MR imaging altered the surgeon's course of treatment and postoperative care. Radiographic and MR images and a review of the literature are provided. (orig.)

  15. Lactate Oxidation Coupled to Iron or Electrode Reduction by Geobacter sulfurreducens PCA

    KAUST Repository

    Call, D. F.

    2011-10-14

    Geobacter sulfurreducens PCA completely oxidized lactate and reduced iron or an electrode, producing pyruvate and acetate intermediates. Compared to the current produced by Shewanella oneidensis MR-1, G. sulfurreducens PCA produced 10-times-higher current levels in lactate-fed microbial electrolysis cells. The kinetic and comparative analyses reported here suggest a prominent role of G. sulfurreducens strains in metaland electrode-reducing communities supplied with lactate. © 2011, American Society for Microbiology.

  16. Lactate Oxidation Coupled to Iron or Electrode Reduction by Geobacter sulfurreducens PCA

    KAUST Repository

    Call, D. F.; Logan, B. E.

    2011-01-01

    Geobacter sulfurreducens PCA completely oxidized lactate and reduced iron or an electrode, producing pyruvate and acetate intermediates. Compared to the current produced by Shewanella oneidensis MR-1, G. sulfurreducens PCA produced 10-times-higher current levels in lactate-fed microbial electrolysis cells. The kinetic and comparative analyses reported here suggest a prominent role of G. sulfurreducens strains in metaland electrode-reducing communities supplied with lactate. © 2011, American Society for Microbiology.

  17. Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging.

    Science.gov (United States)

    Liu, Fang; Jang, Hyungseok; Kijowski, Richard; Bradshaw, Tyler; McMillan, Alan B

    2018-02-01

    Purpose To develop and evaluate the feasibility of deep learning approaches for magnetic resonance (MR) imaging-based attenuation correction (AC) (termed deep MRAC) in brain positron emission tomography (PET)/MR imaging. Materials and Methods A PET/MR imaging AC pipeline was built by using a deep learning approach to generate pseudo computed tomographic (CT) scans from MR images. A deep convolutional auto-encoder network was trained to identify air, bone, and soft tissue in volumetric head MR images coregistered to CT data for training. A set of 30 retrospective three-dimensional T1-weighted head images was used to train the model, which was then evaluated in 10 patients by comparing the generated pseudo CT scan to an acquired CT scan. A prospective study was carried out for utilizing simultaneous PET/MR imaging for five subjects by using the proposed approach. Analysis of covariance and paired-sample t tests were used for statistical analysis to compare PET reconstruction error with deep MRAC and two existing MR imaging-based AC approaches with CT-based AC. Results Deep MRAC provides an accurate pseudo CT scan with a mean Dice coefficient of 0.971 ± 0.005 for air, 0.936 ± 0.011 for soft tissue, and 0.803 ± 0.021 for bone. Furthermore, deep MRAC provides good PET results, with average errors of less than 1% in most brain regions. Significantly lower PET reconstruction errors were realized with deep MRAC (-0.7% ± 1.1) compared with Dixon-based soft-tissue and air segmentation (-5.8% ± 3.1) and anatomic CT-based template registration (-4.8% ± 2.2). Conclusion The authors developed an automated approach that allows generation of discrete-valued pseudo CT scans (soft tissue, bone, and air) from a single high-spatial-resolution diagnostic-quality three-dimensional MR image and evaluated it in brain PET/MR imaging. This deep learning approach for MR imaging-based AC provided reduced PET reconstruction error relative to a CT-based standard within the brain compared

  18. Proton (1H) MR spectroscopy for routine diagnostic evaluation of brain lesions

    International Nuclear Information System (INIS)

    Burtscher, I.M.; Holtaas, S.; Staahlberg, F.; Univ. Hospital, Lund

    1997-01-01

    Purpose: To describe the introduction and performance of proton MR spectroscopy ( 1 H-MRS) in the daily routine of a modern standard MR unit. Material and Methods: Over an 8-month period, 52 patients with brain lesions were studied with 1 H-MRS, using SE and STEAM sequences for chemical-shift imaging and single-volume spectroscopy. The quality of the spectra was graded from 1 (best) to 3, and the main factors influencing the quality of the spectra were evaluated. Results: Of the measurements: 85% were graded as 1; 12% as 2; and 3% as 3. The main reasons for poor spectral quality were: the unfortunate positioning of the VOI; hemorrhage; and/or postoperative changes within the VOI. Of 40 patients with a final diagnosis: MRS provided an increased confidence in MR diagnosis in 18 cases; MRS contributed significantly to preoperative diagnosis in 3 cases; and the spectra were not specific (n=10) or were difficult to evaluate (n=9) owing to reduced quality (grade 2 or 3) in 19 cases. Conclusion: MRS of the brain can provide a high percentage of interpretable spectra and frequently can increase confidence in the MR diagnosis of brain lesions in clinical routine. (orig.)

  19. MR imaging of pituitary macroadenomas before and after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Hald, J.K.; Nakstad, P.H.; Kollevold, T.; Bakke, S.J.; Skalpe, I.O.

    1992-01-01

    MR findings before and after transsphenoidal surgery were evaluated in 6 cases. T1-weighted (TR/TE 600/20) sagittal and coronal images with 2 or 4 acquisitions were obtained, using 3-mm slice thickness and 0.3-mm interslice gaps. Of 18 MR examinations, 13 included coronal i.v. contrast medium enhanced images. Image quality, sinus cavernosus invasion, identification of normal pituitary tissue and tumor size were examined. All MR studied clearly demonstrated the macroadenomas whether 2 or 4 acquisitions were used, and whether i.v. contrast medium was administered or not. Surgically confirmed sinus cavernosus infiltration was seen in 4 patients. The pituitary stalk was identified separate from the tumor in 2 patients, and the gland in one. There was reduction in tumor size over time, indicating that final radiologic assessment after transsphenoidal surgery is best performed 4 to 6 months postoperatively. It should not be necessary to routinely include i.v. contrast medium injection in the postoperative evaluation of macroadenomas. (orig.)

  20. MR microscopy as a research modality

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Kim, Seung Hyup; Han, Man Chung; Lee, Sang Hoon; Lee, Yoon Seong; Yi, Jung Han; Cho, Zang Hee

    1988-01-01

    A combination of high gradient (0.46mT/cm) and small radiofrequency coils (8cm diameter) was used to obtain images with effective thickness of 2.0mm and pixel dimensions as small as 196 μ in the live chick embryo and surgically resected human femoral head with avascular necrosis. The signal-to-noise ratio was sufficient to allow identification of major anatomical structures of live chick embryo and delineation of osteonecrotic segment in femoral head. The changes of signal intensity in necrotic femoral head was well correlated with histopathologic findings. MR microscopy is considered as a good research modality in the field of embryology, teratology and MR tissue characterization

  1. MR microscopy as a research modality

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Heung Sik; Kim, Seung Hyup; Han, Man Chung; Lee, Sang Hoon; Lee, Yoon Seong [College of Medicine, Seoul National University, Seoul (Korea, Republic of); Yi, Jung Han; Cho, Zang Hee [Korea Advanced insititute of Science, Taejon (Korea, Republic of)

    1988-02-15

    A combination of high gradient (0.46mT/cm) and small radiofrequency coils (8cm diameter) was used to obtain images with effective thickness of 2.0mm and pixel dimensions as small as 196 {mu} in the live chick embryo and surgically resected human femoral head with avascular necrosis. The signal-to-noise ratio was sufficient to allow identification of major anatomical structures of live chick embryo and delineation of osteonecrotic segment in femoral head. The changes of signal intensity in necrotic femoral head was well correlated with histopathologic findings. MR microscopy is considered as a good research modality in the field of embryology, teratology and MR tissue characterization.

  2. Integrative analysis of cardiac function and metabolism in patients with idiopathic hypertrophic cardiomyopathy with H-1 cine MR imaging and P-31 MR spectroscopy

    International Nuclear Information System (INIS)

    Wagner, S.; Chew, W.M.; Semelka, R.; Tomei, E.; Caputo, G.; O'Sullivan, M.; Chatterjee, K.; Parmley, W.W.; Wolfe, C.L.; Higgins, C.B.

    1989-01-01

    The purpose of the study was to use MR imaging and P-31 spectroscopy for the functional and metabolic characterization of patients with hypertrophic cardiomyopathy (HCM). Nine patients with HCM underwent combined P-31 spectroscopy (one-dimensional chemical shift imaging) and MR imaging at 1.5 T. MR imaging localized the distribution of ventricular hypertrophy and cine MR imaging quantitated cardiac volumes, contractility, and left ventricular mass. The phosphodiester/phosphocreatine ratio (PDE/PCr) in six HCM patients was not different from normal, but in three patients it was significantly (P <.01) higher. This finding could not be attributed to contractible abnormalities, the distribution of hypertrophy, or the left ventricular mass. The abnormal PDE/PCr ratio was found only in patients with echocardiographic findings of resting left ventricular outflow obstruction but was not associated with severity or distribution of hypertrophy. The study shows the use of combined MR imaging and MR spectroscopy to characterize HCM and possibly to identify abnormal myocardial tissue

  3. Craniopharyngiomas - the utility of contrast medium enhancement for MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Hald, J.K.; Eldevik, O.P.; Brunberg, J.A.; Chandler, W.F.

    1994-01-01

    To evaluate the efficacy of i.v. contrast medium administration in MR imaging at 1.5 T in patients with craniopharyngiomas, MR studies of 10 men and 6 women with pathologically proven craniopharyngiomas were made. The MR images were obtained as 3- to 5-mm-thick coronal (n=13) or axial (n=3) T1-weighted images (T1WI) prior to an following i.v. Gd-DTPA administration. Proton density-(PD) and T2-weighted images (T2WI) were also obtained. Conspicuity of tumor margins, cystic versus solid components, size, location and effect upon adjacent structures were separately characterized in all imaging sequences. In 6 patients contrast medium-enhanced T1WI, PD and T2WI demonstrated cystic tumor components not seen on unenhanced T1WI. There were significant differences (p<0.004) on 2-tailed Student's t-test comparing tumor conspicuity on contrast medium-enhanced T1WI with unenhanced T1WI, PD and T2WI. Optimal tumor delineation on MR imaging of patients with craniopharyngiomas justifies the use of i.v. contrast medium. (orig.)

  4. Examination of human brain tumors in situ with image-localized H-1 MR spectroscopy

    International Nuclear Information System (INIS)

    Luyten, P.R.; Segebarth, C.; Baleriaux, D.; Den Hollander, J.A.

    1987-01-01

    Human brain tumors were examined in situ by combined imaging and H-1 MR spectroscopy at 1.5 T. Water-suppressed localized H-1 MR spectra obtained from the brains of normal volunteers show resonances from lactate, N-acetyl aspartate (NAA), creatine, and choline. Several patients suffering from different brain tumors were examined, showing spectral changes in the region of 0.5-1.5 ppm; spectral editing showed that these changes were not due to lactic acid, but to lipid signals. The NAA signal was decreased in the tumors as compared with normal brain. This study shows that H-1 MR spectroscopy can monitor submillimolar changes in chemical composition of human brain tumors in situ

  5. MR staging of pelvic endometriosis. Role of fat-suppression T1-weighted images

    International Nuclear Information System (INIS)

    Oishi-Tanaka, Yumiko; Itai, Yuji; Anno, Izumi; Matsumoto, Kunihiko; Ebihara, Reiko; Nishida, Masato

    1996-01-01

    We examined whether MR can determine the stage of endometriosis according to the scoring system established and revised by the American Fertility Society (r-AFS), a system which is widely used by gynecologists. We also studied the utility of fat suppression T 1 -weighted images in improving accuracy. Seventeen patients with endometriosis examined by conventional MR were included in this study. All the patients had surgically proved stage III or IV disease. We determined the stage by MR using the following criteria according to the r-AFS system: adnexal masses without normal ovarian tissue were considered deep ovarian lesions, while those with normal tissue were considered superficial. A lack of fat between the lesion and surrounding structures was considered a dense adhesion, and hyperintense spots were considered peritoneal implants. The MR scores of patients with and without fat suppression were correlated with the surgical scores. MR staging corresponded to surgical staging in 15 of the 17 patients. In eight patients, peritoneal implants of less than 1.5 cm were depicted only by fat-suppression images. However, these lesions did not change the score significantly. MR imaging could determine the stage in advanced endometriosis. Fat-suppression could highlight smaller implants. These tiny lesions had little clinical meaning in these advanced cases; however, the clinical value of this technique should be evaluated in milder disease. (author)

  6. Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system

    International Nuclear Information System (INIS)

    Adam, G.; Guenther, R.W.

    1997-01-01

    The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [de

  7. 1H-MR spectroscopy in anorexia nervosa. Reversible cerebral metabolic changes

    International Nuclear Information System (INIS)

    Moeckel, R.; Schlemmer, H.P.; Becker, G.; Koepke, J.; Georgi, M.; Gueckel, C.; Goepel, C.; Schmidt, M.; Hentschel, F.

    1999-01-01

    Purpose: By using localized 1 H-MR spectroscopy in the brain of patients with anorexia nervosa we wanted to verify our preliminary results and to look for a reversibility of the metabolic changes under therapy. Methods: In 22 patients and 17 healthy volunteers (11 follow-up examinations) single voxel 1 H-MR spectroscopy (TE=50 ms, TM=30 ms, TR=1500 ms, voxel (2 cm) 3 , acq.: 256) was used in two different localizations (thalamus and parieto-occipital region). The first examination of the patients was performed before therapy, the follow-up examination at the end of therapy. Results: In both regions of the brain we found a statistically significant elevation of the Cho/Cr-ratio in comparison to normal controls. The follow-up examinations revealed reversibility of the metabolic changes under successful therapy. Conclusion: 1 H-MR spectroscopy reveals metabolic changes in the brain of patients with anorexia nervosa, which are reversible under successful therapy. These metabolic changes can be conclusively explained using a biochemical model. (orig.) [de

  8. Acute cervical spine injuries: prospective MR imaging assessment at a level 1 trauma center.

    Science.gov (United States)

    Katzberg, R W; Benedetti, P F; Drake, C M; Ivanovic, M; Levine, R A; Beatty, C S; Nemzek, W R; McFall, R A; Ontell, F K; Bishop, D M; Poirier, V C; Chong, B W

    1999-10-01

    To determine the weighted average sensitivity of magnetic resonance (MR) imaging in the prospective detection of acute neck injury and to compare these findings with those of a comprehensive conventional radiographic assessment. Conventional radiography and MR imaging were performed in 199 patients presenting to a level 1 trauma center with suspected cervical spine injury. Weighted sensitivities and specificities were calculated, and a weighted average across eight vertebral levels from C1 to T1 was formed. Fourteen parameters indicative of acute injury were tabulated. Fifty-eight patients had 172 acute cervical injuries. MR imaging depicted 136 (79%) acute abnormalities and conventional radiography depicted 39 (23%). For assessment of acute fractures, MR images (weighted average sensitivity, 43%; CI: 21%, 66%) were comparable to conventional radiographs (weighted average sensitivity, 48%; CI: 30%, 65%). MR imaging was superior to conventional radiography in the evaluation of pre- or paravertebral hemorrhage or edema, anterior or posterior longitudinal ligament injury, traumatic disk herniation, cord edema, and cord compression. Cord injuries were associated with cervical spine spondylosis (P < .05), acute fracture (P < .001), and canal stenosis (P < .001). MR imaging is more accurate than radiography in the detection of a wide spectrum of neck injuries, and further study is warranted of its potential effect on medical decision making, clinical outcome, and cost-effectiveness.

  9. MR thermometry for laser-induced thermotherapy at 1.5 tesla; MR-Thermometrie bei 1,5 Tesla zur thermischen Ablation mittels laserinduzierter Thermotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Meister, D.; Huebner, F.; Mack, M.; Vogl, T.J. [Frankfurt Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2007-05-15

    Purpose: Evaluation of thermometry with fast MR sequences for laser-induced interstitial laser therapy (LITT) and verification of the thermometric results with a fiber-optic thermometer. Method and Materials: In vitro experiments were conducted using an agarose gel mixture and pig liver lobes. MR-guided LITT was performed using a laser power between 3 and 15?watts. Thermometry was performed using longitudinal relaxation time T1 and proton resonance frequency shift (PRF) methods under acquisition of amplitude and phase shift images. PRF was measured with a fast spoiled GRE sequence. Four different sequences were used for T1 thermometry: gradient echo (GE), TrueFISP (TRUFI), Saturation Recovery Turbo-FLASH (SRTF) and Inversion Recovery Turbo-FLASH (IRTF) sequences. The temperature was controlled using a fiber-optic Luxtron device and correlated with the MR temperature. The range of applied and monitored temperatures exceeded 80 degrees Celsius. Results: The temperature dependence showed a good linear relationship up to 60 degrees Celsius. Calibration experiments for the T1 method delivered coefficients of determination from 0.977 to 0.997 for agarose and from 0.958 to 0.995 for the pig liver samples. The IRTF sequence had the highest temperature sensitivity (agarose 0.99, liver 1.19). During LITT the TRUE-FISP sequence exhibited a strong nonlinear relationship. R{sup 2} of this sequence was 0.809 in the agarose experiments. The average temperature errors when heated up to 80 degrees Celsius were 3.86 - 11.38 degrees Celsius for Agarose gel and 5.7 - 12.16 degrees Celsius for the liver tissue. SRTF and IRTF sequences exhibited the most linear relationship with temperature but were more dependent on tissue differences. (orig.)

  10. Changes in Microbial Energy Metabolism Measured by Nanocalorimetry during Growth Phase Transitions

    Science.gov (United States)

    Robador, Alberto; LaRowe, Douglas E.; Finkel, Steven E.; Amend, Jan P.; Nealson, Kenneth H.

    2018-01-01

    Calorimetric measurements of the change in heat due to microbial metabolic activity convey information about the kinetics, as well as the thermodynamics, of all chemical reactions taking place in a cell. Calorimetric measurements of heat production made on bacterial cultures have recorded the energy yields of all co-occurring microbial metabolic reactions, but this is a complex, composite signal that is difficult to interpret. Here we show that nanocalorimetry can be used in combination with enumeration of viable cell counts, oxygen consumption rates, cellular protein content, and thermodynamic calculations to assess catabolic rates of an isolate of Shewanella oneidensis MR-1 and infer what fraction of the chemical energy is assimilated by the culture into biomass and what fraction is dissipated in the form of heat under different limiting conditions. In particular, our results demonstrate that catabolic rates are not necessarily coupled to rates of cell division, but rather, to physiological rearrangements of S. oneidensis MR-1 upon growth phase transitions. In addition, we conclude that the heat released by growing microorganisms can be measured in order to understand the physiochemical nature of the energy transformation and dissipation associated with microbial metabolic activity in conditions approaching those found in natural systems. PMID:29449836

  11. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  12. 1H in vivo MR spektroskopie v klinické neurologii

    Czech Academy of Sciences Publication Activity Database

    Starčuk, Zenon; Krupa, P.; Starčuk jr., Zenon; Horký, Jaroslav

    2005-01-01

    Roč. 6, č. 3 (2005), s. 140-148 ISSN 1335-9592 Institutional research plan: CEZ:AV0Z20650511 Keywords : H-1 MR spectroscopy * single-voxel MRS techniques * clinical application of H-1 MRS Subject RIV: FH - Neurology

  13. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

    Science.gov (United States)

    Catana, Ciprian; Wu, Yibao; Judenhofer, Martin S; Qi, Jinyi; Pichler, Bernd J; Cherry, Simon R

    2006-12-01

    PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode (PSAPD) detectors coupled, via short lengths of optical fibers, to arrays of lutetium oxyorthosilicate (LSO) scintillator crystals. The optical fibers are used to minimize electromagnetic interference between the radiofrequency and gradient coils and the PET detector system. The PET detector module components and the complete PET insert assembly are described. PET data were acquired with and without MR sequences running, and detector flood histograms were compared with the ones generated from the data acquired outside the magnet. A uniform MR phantom was also imaged to assess the effect of the PET detector on the MR data acquisition. Simultaneous PET and MRI studies of a mouse were performed ex vivo. PSAPDs can be successfully used to read out large numbers of scintillator crystals coupled through optical fibers with acceptable performance in terms of energy and timing resolution and crystal identification. The PSAPD-LSO detector performs well in the 7-T magnet, and no visible artifacts are detected in the MR images using standard pulse sequences. The first images from the complete system have been successfully acquired and reconstructed, demonstrating that simultaneous PET and MRI studies are feasible and opening up interesting possibilities for dual-modality molecular imaging studies.

  14. Role of endorectal MR imaging and MR spectroscopic imaging in defining treatable intraprostatic tumor foci in prostate cancer: Quantitative analysis of imaging contour compared to whole-mount histopathology

    International Nuclear Information System (INIS)

    Anwar, Mekhail; Westphalen, Antonio C.; Jung, Adam J.; Noworolski, Susan M.; Simko, Jeffry P.; Kurhanewicz, John; Roach, Mack; Carroll, Peter R.; Coakley, Fergus V.

    2014-01-01

    Purpose: To investigate the role of endorectal MR imaging and MR spectroscopic imaging in defining the contour of treatable intraprostatic tumor foci in prostate cancer, since targeted therapy requires accurate target volume definition. Materials and methods: We retrospectively identified 20 patients with prostate cancer who underwent endorectal MR imaging and MR spectroscopic imaging prior to radical prostatectomy and subsequent creation of detailed histopathological tumor maps from whole-mount step sections. Two experienced radiologists independently reviewed all MR images and electronically contoured all suspected treatable (⩾0.5 cm 3 ) tumor foci. Deformable co-registration in MATLAB was used to calculate the margin of error between imaging and histopathological contours at both capsular and non-capsular surfaces and the treatment margin required to ensure at least 95% tumor coverage. Results: Histopathology showed 17 treatable tumor foci in 16 patients, of which 8 were correctly identified by both readers and an additional 2 were correctly identified by reader 2. For all correctly identified lesions, both readers accurately identified that tumor contacted the prostatic capsule, with no error in contour identification. On the non-capsular border, the median distance between the imaging and histopathological contour was 1.4 mm (range, 0–12). Expanding the contour by 5 mm at the non-capsular margin included 95% of tumor volume not initially covered within the MR contour. Conclusions: Endorectal MR imaging and MR spectroscopic imaging can be used to accurately contour treatable intraprostatic tumor foci; adequate tumor coverage is achieved by expanding the treatment contour at the non-capsular margin by 5 mm

  15. MR fingerprinting with simultaneous B1 estimation.

    Science.gov (United States)

    Buonincontri, Guido; Sawiak, Stephen J

    2016-10-01

    MR fingerprinting (MRF) can be used for quantitative estimation of physical parameters in MRI. Here, we extend the method to incorporate B1 estimation. The acquisition is based on steady state free precession MR fingerprinting with a Cartesian trajectory. To increase the sensitivity to the B1 profile, abrupt changes in flip angle were introduced in the sequence. Slice profile and B1 effects were included in the dictionary and the results from two- and three-dimensional (3D) acquisitions were compared. Acceleration was demonstrated using retrospective undersampling in the phase encode directions of 3D data exploiting redundancy between MRF frames at the edges of k-space. Without B1 estimation, T2 and B1 were inaccurate by more than 20%. Abrupt changes in flip angle improved B1 maps. T1 and T2 values obtained with the new MRF methods agree with classical spin echo measurements and are independent of the B1 field profile. When using view sharing reconstruction, results remained accurate (error Reson Med 76:1127-1135, 2016. © 2015 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. © 2015 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  16. MR appearance of normal and abnormal bile: Correlation with imaging and endoscopic finding

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Kyung [Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Pusan National University, Busan 602-739 (Korea, Republic of); Kim, Suk, E-mail: kimsuk@medimail.co.kr [Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Pusan National University, Busan 602-739 (Korea, Republic of); Lee, Jun Woo; Lee, Suk Hong [Department of Radiology, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Pusan National University, Busan 602-739 (Korea, Republic of); Kang, Dae Hwan; Kim, Dong Uk; Kim, Gwang Ha [Department of Internal Medicine, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Pusan National University, Busan 602-739 (Korea, Republic of); Seo, Hyung Il [Department of Surgery, Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Pusan National University, Busan 602-739 (Korea, Republic of)

    2010-11-15

    Identification of abnormal bile related to various pathological processes in the pancreaticobiliary tract can be important in the diagnosis of disease and the determination of appropriate treatment. Magnetic resonance (MR) imaging can allow comprehensive evaluation of abnormal bile because MR usually provides better tissue characterization than other imaging modalities. A high-intensity signal from bile is frequently encountered on T1-weighted images and can be seen in concentrated bile, sludge, stones, or hemobilia. Contrast-enhanced MR features, such as inhomogeneous hepatic enhancement in the arterial phase and papillitis or mild-to-moderate bile duct wall thickening with enhancement, along with clinical characteristics, may suggest clinically significant bile, such as sludge or purulent bile, rather than merely concentrated bile. A history of trauma and appropriate imaging findings in the hepatobiliary tract can support a diagnosis of hemobilia. MR imaging may assist in diagnosing intraductal papillary mucinous neoplasm of the bile duct via detection of an intraductal mass or several indirect signs, suggesting a large amount of mucin. Additionally, Gd-EOB-DTPA-enhanced MR may delineate mucin as a filling defect surrounding hyperintense bile. A floating filling defect on all MR sequences is helpful in discriminating pneumobilia from other intraluminal filling defects. Familiarity with the various different MR features of abnormal bile signals can therefore facilitate accurate diagnosis and treatment.

  17. MR appearance of normal and abnormal bile: Correlation with imaging and endoscopic finding

    International Nuclear Information System (INIS)

    Lee, Nam Kyung; Kim, Suk; Lee, Jun Woo; Lee, Suk Hong; Kang, Dae Hwan; Kim, Dong Uk; Kim, Gwang Ha; Seo, Hyung Il

    2010-01-01

    Identification of abnormal bile related to various pathological processes in the pancreaticobiliary tract can be important in the diagnosis of disease and the determination of appropriate treatment. Magnetic resonance (MR) imaging can allow comprehensive evaluation of abnormal bile because MR usually provides better tissue characterization than other imaging modalities. A high-intensity signal from bile is frequently encountered on T1-weighted images and can be seen in concentrated bile, sludge, stones, or hemobilia. Contrast-enhanced MR features, such as inhomogeneous hepatic enhancement in the arterial phase and papillitis or mild-to-moderate bile duct wall thickening with enhancement, along with clinical characteristics, may suggest clinically significant bile, such as sludge or purulent bile, rather than merely concentrated bile. A history of trauma and appropriate imaging findings in the hepatobiliary tract can support a diagnosis of hemobilia. MR imaging may assist in diagnosing intraductal papillary mucinous neoplasm of the bile duct via detection of an intraductal mass or several indirect signs, suggesting a large amount of mucin. Additionally, Gd-EOB-DTPA-enhanced MR may delineate mucin as a filling defect surrounding hyperintense bile. A floating filling defect on all MR sequences is helpful in discriminating pneumobilia from other intraluminal filling defects. Familiarity with the various different MR features of abnormal bile signals can therefore facilitate accurate diagnosis and treatment.

  18. Integrated genome-based studies of Shewanella ecophysiology

    Energy Technology Data Exchange (ETDEWEB)

    Segre Daniel; Beg Qasim

    2012-02-14

    This project was a component of the Shewanella Federation and, as such, contributed to the overall goal of applying the genomic tools to better understand eco-physiology and speciation of respiratory-versatile members of Shewanella genus. Our role at Boston University was to perform bioreactor and high throughput gene expression microarrays, and combine dynamic flux balance modeling with experimentally obtained transcriptional and gene expression datasets from different growth conditions. In the first part of project, we designed the S. oneidensis microarray probes for Affymetrix Inc. (based in California), then we identified the pathways of carbon utilization in the metal-reducing marine bacterium Shewanella oneidensis MR-1, using our newly designed high-density oligonucleotide Affymetrix microarray on Shewanella cells grown with various carbon sources. Next, using a combination of experimental and computational approaches, we built algorithm and methods to integrate the transcriptional and metabolic regulatory networks of S. oneidensis. Specifically, we combined mRNA microarray and metabolite measurements with statistical inference and dynamic flux balance analysis (dFBA) to study the transcriptional response of S. oneidensis MR-1 as it passes through exponential, stationary, and transition phases. By measuring time-dependent mRNA expression levels during batch growth of S. oneidensis MR-1 under two radically different nutrient compositions (minimal lactate and nutritionally rich LB medium), we obtain detailed snapshots of the regulatory strategies used by this bacterium to cope with gradually changing nutrient availability. In addition to traditional clustering, which provides a first indication of major regulatory trends and transcription factors activities, we developed and implemented a new computational approach for Dynamic Detection of Transcriptional Triggers (D2T2). This new method allows us to infer a putative topology of transcriptional dependencies

  19. SU-E-J-217: Multiparametric MR Imaging of Cranial Tumors On a Dedicated 1.0T MR Simulator Prior to Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Glide-Hurst, C; Liu, M; Hearshen, D; Brown, S; Siddiqui, S; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2015-06-15

    Purpose: Quantitative magnetic resonance imaging (MRI) of cranial lesions prior to stereotactic radiosurgery (SRS) may improve treatment planning and provide potential prognostic value. The practicality and logistics of acquiring advanced multiparametric MRI sequences to measure vascular and cellular properties of cerebral tumors are explored on a 1.0 Tesla MR Simulator. Methods: MR simulation was performed immediately following routine CT simulation on a 1T MR Simulator. MR sequences used were in the order they were performed: T2-Weighted Turbo Spin Echo (T2W-TSE), T2 FLAIR, Diffusion-weighted (DWI, b = 0, 800 to generate an apparent diffusion coefficient (ADC) map), 3D T1-Weighted Fast Field Echo (T1W-FFE), Dynamic Contrast Enhanced (DCE) and Post Gadolinium Contrast Enhanced 3D T1W-FFE images. T1 pre-contrast values was generated by acquiring six different flip angles. The arterial input function was derived from arterial pixels in the perfusion images selected manually. The extended Tofts model was used to generate the permeability maps. Routine MRI scans took about 30 minutes to complete; the additional scans added 12 minutes. Results: To date, seven patients with cerebral tumors have been imaged and tumor physiology characterized. For example, on a glioblastoma patient, the volume contoured on T1 Gd images, ADC map and the pharmacokinetic map (Ktrans) were 1.9, 1.4, and 1.5 cc respectively with strong spatial correlation. The mean ADC value of the entire volume was 1141 μm2/s while the value in the white matter was 811 μm2/s. The mean value of Ktrans was 0.02 min-1 in the tumor volume and 0.00 in the normal white matter. Conclusion: Our initial results suggest that multiparametric MRI sequences may provide a more quantitative evaluation of vascular and tumor properties. Implementing functional imaging during MR-SIM may be particularly beneficial in assessing tumor extent, differentiating radiation necrosis from tumor recurrence, and establishing reliable

  20. Quantitative MR imaging and spectroscopy of brain tumours: a step forward?

    Energy Technology Data Exchange (ETDEWEB)

    Wagnerova, Dita; Herynek, Vit; Dezortova, Monika; Jiru, Filip; Skoch, Antonin; Hajek, Milan [Institute for Clinical and Experimental Medicine, Department of Diagnostic and Interventional Radiology, Prague (Czech Republic); Malucelli, Alberto; Bartos, Robert; Sames, Martin [JE Purkyne University and Masaryk Hospital, Department of Neurosurgery, Usti nad Labem (Czech Republic); Vymazal, Josef [Na Homolce Hospital, Department of Radiology, Prague (Czech Republic); Urgosik, Dusan [Na Homolce Hospital, Stereotactic and Radiation Neurosurgery, Prague (Czech Republic); Syrucek, Martin [Na Homolce Hospital, Department of Pathology, Prague (Czech Republic)

    2012-11-15

    A prospective quantitative MR study of brain tumours was performed to show the potential of combining different MR techniques to distinguish various disease processes in routine clinical practice. Twenty-three patients with various intracranial tumours before treatment (diagnosis confirmed by a biopsy) and 59 healthy subjects were examined on a 3-T system by conventional MR imaging, 1H spectroscopic imaging, diffusion tensor imaging and T2 relaxometry. Metabolic concentrations and their ratios, T2 relaxation times and mean diffusivities were calculated and correlated on a pixel-by-pixel basis and compared to control data. Different tumour types and different localisations revealed specific patterns of correlations between metabolic concentrations and mean diffusivity or T2 relaxation times. The patterns distinguish given tissue states in the examined area: healthy tissue, tissue infiltrated by tumour, active tumour, oedema infiltrated by tumour, oedema, etc. This method is able to describe the complexity of a highly heterogeneous tissue in the tumour and its vicinity, and determines crucial parameters for tissue differentiation. A combination of different MR parameters on a pixel-by-pixel basis in individual patients enables better identification of the tumour type, direction of proliferation and assessment of the tumour extension. (orig.)

  1. LOCUS MR: Localization of unaffected spins in MR tomography and MR spectroscopy

    International Nuclear Information System (INIS)

    Matthael, D.; Haase, A.

    1986-01-01

    Different pulse sequences have been proposed for localized in vivo MR spectroscopy. For localized MR tomography and MR spectroscopy, a method is proposed, dubbed LOCUS (LOCalization of Unaffected Spins) MR. The method uses the initial saturation of regions surrounding the region of interest (ROI) in the presence of gradients. This is followed by a conventional MR study of the unaffected ROI. In animals, human extremities, and phantoms, proton MR studies demonstrated that the method provides an optimal signal-to-noise ratio, an easily variable ROI, and ROI shim. The method can be combined with two- and three-dimensional imaging, and it allows localized measurement of MR parameters. The multinuclear capability is discussed

  2. Comparative genomic reconstruction of transcriptional networks controlling central metabolism in the Shewanella genus

    Directory of Open Access Journals (Sweden)

    Kovaleva Galina

    2011-06-01

    . oneidensis MR-1. Analysis of correlations in gene expression patterns helps to interpret the reconstructed regulatory network. The inferred regulatory interactions will provide an additional regulatory constrains for an integrated model of metabolism and regulation in S. oneidensis MR-1.

  3. MR staging of pelvic endometriosis. Role of fat-suppression T{sub 1}-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Oishi-Tanaka, Yumiko; Itai, Yuji; Anno, Izumi; Matsumoto, Kunihiko; Ebihara, Reiko; Nishida, Masato [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    1996-05-01

    We examined whether MR can determine the stage of endometriosis according to the scoring system established and revised by the American Fertility Society (r-AFS), a system which is widely used by gynecologists. We also studied the utility of fat suppression T{sub 1}-weighted images in improving accuracy. Seventeen patients with endometriosis examined by conventional MR were included in this study. All the patients had surgically proved stage III or IV disease. We determined the stage by MR using the following criteria according to the r-AFS system: adnexal masses without normal ovarian tissue were considered deep ovarian lesions, while those with normal tissue were considered superficial. A lack of fat between the lesion and surrounding structures was considered a dense adhesion, and hyperintense spots were considered peritoneal implants. The MR scores of patients with and without fat suppression were correlated with the surgical scores. MR staging corresponded to surgical staging in 15 of the 17 patients. In eight patients, peritoneal implants of less than 1.5 cm were depicted only by fat-suppression images. However, these lesions did not change the score significantly. MR imaging could determine the stage in advanced endometriosis. Fat-suppression could highlight smaller implants. These tiny lesions had little clinical meaning in these advanced cases; however, the clinical value of this technique should be evaluated in milder disease. (author)

  4. Use of atomic force microscopy and transmission electron microscopy for correlative studies of bacterial capsules.

    Science.gov (United States)

    Stukalov, Oleg; Korenevsky, Anton; Beveridge, Terry J; Dutcher, John R

    2008-09-01

    Bacteria can possess an outermost assembly of polysaccharide molecules, a capsule, which is attached to their cell wall. We have used two complementary, high-resolution microscopy techniques, atomic force microscopy (AFM) and transmission electron microscopy (TEM), to study bacterial capsules of four different gram-negative bacterial strains: Escherichia coli K30, Pseudomonas aeruginosa FRD1, Shewanella oneidensis MR-4, and Geobacter sulfurreducens PCA. TEM analysis of bacterial cells using different preparative techniques (whole-cell mounts, conventional embeddings, and freeze-substitution) revealed capsules for some but not all of the strains. In contrast, the use of AFM allowed the unambiguous identification of the presence of capsules on all strains used in the present study, including those that were shown by TEM to be not encapsulated. In addition, the use of AFM phase imaging allowed the visualization of the bacterial cell within the capsule, with a depth sensitivity that decreased with increasing tapping frequency.

  5. MR imaging of normal bone marrow; Obraz MR prawidlowego szpiku kostnego

    Energy Technology Data Exchange (ETDEWEB)

    Stajgis, M.; Paprzycki, W. [Osrodek Diagnostyki Obrazowej IR, Akademia Medyczna, Poznan (Poland)

    1994-12-31

    Principles of MR bone marrow imaging on the basis of retrospective analysis of MR examinations of bone marrow in different anatomic sites in 200 patients have been discussed. Significance of different physiologic factors and processes such as age, steatosis, osteoporosis, conversion and reconversion, which influence on MR bone marrow images, have been emphasized. T1-weighted images obtained with spin-echo sequences give the most of information about bone marrow structure in MR. Thorough knowledge of bone marrow physiology and clinical status of the patient is indispensable in correct interpretation of hypointensive lesions on T1-weighted images. When presence of disseminated bone marrow disease is suspected, authors propose routine imaging of lumbar vertebral column, pelvis and proximal parts of femoral bones. (author) 7 refs, 7 figs

  6. MR tractography

    International Nuclear Information System (INIS)

    Kinosada, Yasutomi; Okuda, Yasuyuki; Ono, Mototsugu

    1993-01-01

    We developed a new noninvasive technique to visualize the anatomical structure of the nerve fiber system in vivo, and named this technique magnetic resonance (MR) tractography and the acquired image an MR tractogram. MR tractography has two steps. One is to obtain diffusion-weighted images sensitized along axes appropriate for depicting the intended nerve fibers with anisotropic water diffusion MR imaging. The other is to extract the anatomical structure of the nerve fiber system from a series of diffusion-weighted images by the maximum intensity projection method. To examine the clinical usefulness of the proposed technique, many contiguous, thin (3 mm) coronal two-dimensional sections of the brain were acquired sequentially in normal volunteers and selected patients with paralyses, on a 1.5 Tesla MR system (Signa, GE) with an ECG-gated Stejskal-Tanner pulse sequence. The structure of the nerve fiber system of normal volunteers was almost the same as the anatomy. The tractograms of patients with paralyses clearly showed the degeneration of nerve fibers and were correlated with clinical symptoms. MR tractography showed great promise for the study of neuroanatomy and neuroradiology. (author)

  7. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients

    International Nuclear Information System (INIS)

    Grueneisen, Johannes; Sawicki, Lino Morris; Wetter, Axel; Kirchner, Julian; Kinner, Sonja; Aktas, Bahriye; Forsting, Michael; Ruhlmann, Verena; Umutlu, Lale

    2017-01-01

    Objectives: To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. Methods: A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Results: Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p < 0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p > 0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2 w HASTE and diffusion-weighted imaging. Conclusion: Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer

  8. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Grueneisen, Johannes, E-mail: Johannes.grueneisen@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Sawicki, Lino Morris [Department of Diagnostic and Interventional Radiology, University Hospital, Dusseldorf, University of Dusseldorf, D-40225 Dusseldorf (Germany); Wetter, Axel [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Kirchner, Julian [Department of Diagnostic and Interventional Radiology, University Hospital, Dusseldorf, University of Dusseldorf, D-40225 Dusseldorf (Germany); Kinner, Sonja [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Aktas, Bahriye [Department of Obstetrics and Gynecology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Forsting, Michael [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Ruhlmann, Verena [Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Umutlu, Lale [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany)

    2017-04-15

    Objectives: To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. Methods: A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Results: Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p < 0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p > 0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2 w HASTE and diffusion-weighted imaging. Conclusion: Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer

  9. SU-F-I-51: CT/MR Image Deformation: The Clinical Assessment QA in Target Delineation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C; Chen, Y [Monmouth Medical Center, Long Branch, NJ (United States)

    2016-06-15

    Purpose: To study the deformation effects in CT/MR image registration of head and neck (HN) cancers. We present a clinical indication in guiding and simplifying registration procedures of this process while CT images possessed artifacts. Methods: CT/MR image fusion provides better soft tissue contrast in intracranial GTV definition with artifacts. However, whether the fusion process should include the deformation process is questionable and not recommended. We performed CT/MR image registration of a HN patient with tonsil GTV and nodes delineation on Varian Velocity™ system. Both rigid transformation and deformable registration of the same CT/MR imaging data were processed separately. Physician’s selection of target delineation was implemented to identify the variations. Transformation matrix was shown with visual identification, as well as the deformation QA numbers and figures were assessed. Results: The deformable CT/MR images were traced with the calculated matrix, both translation and rotational parameters were summarized. In deformable quality QA, the calculated Jacobian matrix was analyzed, which the min/mean/max of 0.73/0/99/1.37, respectively. Jacobian matrix of right neck node was 0.84/1.13/1.41, which present dis-similarity of the nodal area. If Jacobian = 1, the deformation is at the optimum situation. In this case, the deformation results have shown better target delineation for CT/MR deformation than rigid transformation. Though the root-mean-square vector difference is 1.48 mm, with similar rotational components, the cord and vertebrae position were aligned much better in the deformable MR images than the rigid transformation. Conclusion: CT/MR with/without image deformation presents similar image registration matrix; there were significant differentiate the anatomical structures in the region of interest by deformable process. Though vendor suggested only rigid transformation between CT/MR assuming the geometry remain similar, our findings

  10. Hyperintense globus pallidus on T1-weighted MR imaging in acute kernicterus: is it common or rare?

    Energy Technology Data Exchange (ETDEWEB)

    Coskun, Abdulhakim; Yikilmaz, Ali; Karahan, Okkes Ibrahim; Manav, Ali [Erciyes University Medical School, Department of Radiology, Kayseri (Turkey); Kumandas, Sefer [Erciyes University Medical School, Department of Neuropediatry, Kayseri (Turkey); Akcakus, Mustafa [Erciyes University Medical School, Department of Neonatalogy, Kayseri (Turkey)

    2005-06-01

    Globus pallidus involvement is a well-known magnetic resonance (MR) imaging finding of acute kernicterus. However, it is not clear how early the involvement of globus pallidus occurs and whether or not it is seen in every case. Therefore, we aimed to investigate the globus pallidus involvement in 13 neonates with acute kernicterus by MR imaging. Thirteen neonates who were admitted with jaundice, encephalopathy and indirect hyperbilirubinemia (mean, 37.0 mg/dl) were prospectively evaluated with cranial MR imaging. Pathological signal changes were noted concerning the globus pallidus. Eight of the 13 patients demonstrated bilateral, symmetric increased signal intensity in the globus pallidus on T1-weighted MR imaging. These lesions were not apparent on T2-weighted images. Multiple parenchymal punctuate T1 hyperintense lesions were detected in one patient without globus pallidus involvement. This appearance was consistent with hemorrhage. The MR imaging findings of the other four patients showed no evidence of abnormality. The symmetric involvement of globus pallidus seen as hyperintense on T1-weighted MR imaging is a common and characteristic finding of acute kernicterus. (orig.)

  11. Hyperintense globus pallidus on T1-weighted MR imaging in acute kernicterus: is it common or rare?

    International Nuclear Information System (INIS)

    Coskun, Abdulhakim; Yikilmaz, Ali; Karahan, Okkes Ibrahim; Manav, Ali; Kumandas, Sefer; Akcakus, Mustafa

    2005-01-01

    Globus pallidus involvement is a well-known magnetic resonance (MR) imaging finding of acute kernicterus. However, it is not clear how early the involvement of globus pallidus occurs and whether or not it is seen in every case. Therefore, we aimed to investigate the globus pallidus involvement in 13 neonates with acute kernicterus by MR imaging. Thirteen neonates who were admitted with jaundice, encephalopathy and indirect hyperbilirubinemia (mean, 37.0 mg/dl) were prospectively evaluated with cranial MR imaging. Pathological signal changes were noted concerning the globus pallidus. Eight of the 13 patients demonstrated bilateral, symmetric increased signal intensity in the globus pallidus on T1-weighted MR imaging. These lesions were not apparent on T2-weighted images. Multiple parenchymal punctuate T1 hyperintense lesions were detected in one patient without globus pallidus involvement. This appearance was consistent with hemorrhage. The MR imaging findings of the other four patients showed no evidence of abnormality. The symmetric involvement of globus pallidus seen as hyperintense on T1-weighted MR imaging is a common and characteristic finding of acute kernicterus. (orig.)

  12. Part-body hyperthermia with a radiofrequency multiantenna applicator under online control in 1,5 T MR-tomograph

    International Nuclear Information System (INIS)

    Wust, P.; Gellermann, J.; Faehling, H.; Wlodarczyk, W.; Felix, R.; Seebass, M.; Turner, P.; Nadobny, J.; Rau, B.; Hildebrandt, B.; Schlag, P.M.; Oppelt, A.

    2004-01-01

    Objective of this study is the integration of a multiantenna applicator for part-body hyperthermia (BSD 2000/3D) in a 1.5 T MR-tomograph (Siemens Magnetom Symphony) in order to perform noninvasive MR monitoring in real time to increase safety and effectiveness of heat treatments. The positioning unit is mechanically coupled to the MR gantry from the back side and the body coil is utilised for imaging. For that purpose, the hyperthermia antenna system (100 MHz, 1.500 W) and the MR receiver(63.9 MHs) have to be decoupled in terms of high frequency (filter) and electromagnetically (emc). The processing of MR data sets is performed in a hyperthermia planning system. A simultaneous operation of radiofrequency hyperthermia and MR system is possible at clinically relevant power levels. MR imaging is used for tumor diagnostics (standard spin echo sequences), for hyperthermia planning (T1-weighted gradient echo sequences in equal- and opposed-phase techniques), and for temperature measurements according to the proton resonance frequency method (PRF method, phase evaluation registration using a gradient echo sequence with long echo time). In 33 patients with advanced pelvic and abdominal tumors we performed 150 heat sessions under MR monitoring. For 70% of these patients a visualisation of temperature sensitive data during treatment was possible. The evaluated difference images represent a superposition of real temperature increase and a (temperature-induced) perfusion elevation. The hybrid approach renders development of part body hyperthermia possible as an MR-controlled intervention in radiology. (orig.) [de

  13. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Science.gov (United States)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Aarsvold, John N.; Raghunath, Nivedita; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.; Votaw, John R.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [11C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR

  14. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road Northeast, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Sciences, Emory University, Atlanta, Georgia 30322 (United States); Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Aarsvold, John N. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Nuclear Medicine Service, Atlanta Veterans Affairs Medical Center, Atlanta, Georgia 30033 (United States); Cervo, Morgan; Stark, Rebecca [The Medical Physics Graduate Program in the George W. Woodruff School, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Meltzer, Carolyn C. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Neurology and Department of Psychiatry and Behavior Sciences, Emory University School of Medicine, Atlanta, Georgia 30322 (United States)

    2012-10-15

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  15. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients.

    Science.gov (United States)

    Grueneisen, Johannes; Sawicki, Lino Morris; Wetter, Axel; Kirchner, Julian; Kinner, Sonja; Aktas, Bahriye; Forsting, Michael; Ruhlmann, Verena; Umutlu, Lale

    2017-04-01

    To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (psequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p>0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2w HASTE and diffusion-weighted imaging. Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer recurrences in the three PET/MR readings, the application of contrast-agent and the

  16. SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lim, T; Wang, J; Frank, S; Stafford, R; Bruno, T; Bathala, T; Mahmood, U; Pugh, T; Ibbott, G; Kudchadker, R [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    .2±1.6mm in patients with no endorectal coil, 2.3±0.8mm in patients with 30cc-PFC-filled endorectal-coil and 5.0±1.8mm in patients with 50cc-PFC-filled endorectal-coil. Conclusion: An MR protocol to visualize positive-contrast Sirius markers to assist in the identification of negative-contrast seeds was demonstrated. S Frank is a co-founder of C4 Imaging LLC, the manufacturer of the MRI markers.

  17. SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

    International Nuclear Information System (INIS)

    Lim, T; Wang, J; Frank, S; Stafford, R; Bruno, T; Bathala, T; Mahmood, U; Pugh, T; Ibbott, G; Kudchadker, R

    2015-01-01

    .2±1.6mm in patients with no endorectal coil, 2.3±0.8mm in patients with 30cc-PFC-filled endorectal-coil and 5.0±1.8mm in patients with 50cc-PFC-filled endorectal-coil. Conclusion: An MR protocol to visualize positive-contrast Sirius markers to assist in the identification of negative-contrast seeds was demonstrated. S Frank is a co-founder of C4 Imaging LLC, the manufacturer of the MRI markers

  18. MR imaging of abdominopelvic involvement in neurofibromatosis type 1: a review of 43 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zacharia, T. Thomas [Massachusetts General Hospital, Department of Radiology, Boston, MA (United States); Jaramillo, Diego [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Poussaint, Tina Young [Children' s Hospital Boston, Department of Radiology, Boston, MA (United States); Korf, Bruce [University of Alabama at Birmingham Hospital, Department of Genetics, Birmingham, AL (United States)

    2005-03-01

    Plexiform neurofibromas are a frequent complication of neurofibromatosis type 1. This article discusses MR imaging findings and distribution of plexiform neurofibromas in the abdomen and pelvis. To define the most prevalent patterns of involvement and MR imaging findings in abdominopelvic neurofibromatosis type 1. We reviewed the MR appearance of abdominopelvic lesions in 23 male and 20 female patients (median age: 16 years) with type 1 neurofibromatosis. The patients were part of a multi-institutional study of 300 patients. Imaging included coronal or sagittal, and axial short tau inversion recovery images. The most common abdominopelvic involvement was in the abdominopelvic wall (n=28, 65%) and lumbosacral plexus (n=27, 63%). Retroperitoneal involvement was frequent (n=15, 35%). Lesions were less often intraperitoneal (21%) (P=0.001). Pelvic disease (n=27, 63%), neural canal involvement (n=18, 42%), and hydronephrosis (n=4, 9%) were also noted. Target-like appearance of plexiform lesions was noted in more than half the patients. Abdominopelvic involvement in neurofibromatosis type 1 is primarily extraperitoneal. Although lesions are most prevalent in the abdominopelvic wall and lumbosacral plexus, retroperitoneal and pelvic involvement is common and usually affects important organs. MR imaging added information in the initial and follow-up clinical evaluation of these patients. (orig.)

  19. MR imaging of articular cartilage; Gelenkknorpel in der MR-Tomographie

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, F.K.W.; Muhle, C.; Heller, M.; Brossmann, J. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie

    2001-04-01

    MR imaging has evolved to the best non-invasive method for the evaluation of articular cartilage. MR imaging helps to understand the structure and physiology of cartilage, and to diagnose cartilage lesions. Numerous studies have shown high accuracy and reliability concerning detection of cartilage lesions and early changes in both structure and biochemistry. High contrast-to-noise ratio and high spatial resolution are essential for analysis of articular cartilage. Fat-suppressed 3D-T{sub 1} weighted gradient echo and T{sub 2}-weighted fast spin echo sequences with or without fat suppression are recommended for clinical routine. In this article the anatomy and pathology of hyaline articular cartilage and the complex imaging characteristics of hyaline cartilage will be discussed. (orig.) [German] Die MR-Tomographie hat sich zur besten nichtinvasiven bildgebenden Methode fuer die Untersuchung von Gelenkknorpel entwickelt. Die MR-Tomographie liefert einen Beitrag zum Verstaendnis der Knorpelstruktur und der Physiologie sowie zur Diagnostik von Knorpelschaeden. Zahlreiche MR-Studien konnten eine hohe Genauigkeit und Zuverlaessigkeit bei der Detektion chondraler Laesionen sowie frueher Veraenderungen struktureller und biochemischer Natur zeigen. Neben einem hohen Kontrast/Rausch-Verhaeltnis ist fuer die Gelenkknorpelanalyse eine hohe raeumliche Aufloesung erforderlich. Im klinischen Routinebetrieb empfehlen sich fuer die Erkennung von Knorpellaesionen besonders fettunterdrueckte 3D-T{sub 1}-gewichtete Gradientenecho- und T{sub 2}-gewichtete Fastspinecho-Sequenzen mit oder ohne Fettunterdrueckung. Die vorliegende Arbeit geht auf die Anatomie und Pathologie des hyalinen Gelenkknorpels ein und diskutiert das komplexe MR-Signalverhalten. (orig.)

  20. Septum-like structures in lipoma and liposarcoma: MR imaging and pathologic correlation

    International Nuclear Information System (INIS)

    Hosono, M.; Kobayashi, H.; Fujimoto, R.; Kotoura, Y.; Tsuboyama, T.; Matsusue, Y.; Nakamura, T.; Itoh, T.; Konishi, J.

    1997-01-01

    Objective. To investigate the septum-like structures in predominantly lipomatous tumors, by correlating fat-suppressed MR images with histopathologic findings. Design and patients. The MR findings of three cases of well-differentiated liposarcoma (atypical lipoma), one case of lipoma-like component of dedifferentiated liposarcoma, and nine cases of lipoma were analyzed. T1-, T2-, and fat-suppressed T1-weighted images after Gd-DTPA administration were obtained. Surgical specimens from five patients (four with liposarcoma and one with lipoma) were also scanned with a MR unit, and compared with the pathologic findings. Results and conclusions. Enhancement features of lipoma and liposarcoma were well visualized on fat-suppressed T1-weighted images after Gd-DTPA administration. The septum-like structures of liposarcoma are thick and enhanced considerably, while septa of lipoma are thin and enhanced only slightly. Pathologically, the septum-like structures of liposarcoma contained muscle fibers and the septa of lipoma represented fibrous capsule. Identification of well-enhanced septa in a predominantly lipomatous tumor helps to differentiate malignant tumors from lipomas. As the septum-like structures of liposarcoma contain a skeletal muscle component the tumor might need more extensive surgical procedures including resection of adjacent muscles. (orig.). With 4 figs., 1 tab

  1. Physiological and transcriptional approaches reveal connection between nitrogen and manganese cycles in Shewanella algae C6G3

    Science.gov (United States)

    Aigle, Axel; Bonin, Patricia; Iobbi-Nivol, Chantal; Méjean, Vincent; Michotey, Valérie

    2017-03-01

    To explain anaerobic nitrite/nitrate production at the expense of ammonium mediated by manganese oxide (Mn(IV)) in sediment, nitrate and manganese respirations were investigated in a strain (Shewanella algae C6G3) presenting these features. In contrast to S. oneidensis MR-1, a biotic transitory nitrite accumulation at the expense of ammonium was observed in S. algae during anaerobic growth with Mn(IV) under condition of limiting electron acceptor, concomitantly, with a higher electron donor stoichiometry than expected. This low and reproducible transitory accumulation is the result of production and consumption since the strain is able to dissimilative reduce nitrate into ammonium. Nitrite production in Mn(IV) condition is strengthened by comparative expression of the nitrate/nitrite reductase genes (napA, nrfA, nrfA-2), and rates of the nitrate/nitrite reductase activities under Mn(IV), nitrate or fumarate conditions. Compared with S. oneidensis MR-1, S. algae contains additional genes that encode nitrate and nitrite reductases (napA-α and nrfA-2) and an Outer Membrane Cytochrome (OMC)(mtrH). Different patterns of expression of the OMC genes (omcA, mtrF, mtrH and mtrC) were observed depending on the electron acceptor and growth phase. Only gene mtrF-2 (SO1659 homolog) was specifically expressed under the Mn(IV) condition. Nitrate and Mn(IV) respirations seem connected at the physiological and transcriptional levels.

  2. Experimental validation of hyperthermia SAR treatment planning using MR B1+ imaging

    International Nuclear Information System (INIS)

    Berg, Cornelis A T van den; Bartels, Lambertus W; Leeuw, Astrid A C De; Lagendijk, Jan J W; Kamer, Jeroen B Van de

    2004-01-01

    In this paper the concept of using B 1+ imaging as a means to validate SAR models for radiofrequency hyperthermia is presented. As in radiofrequency hyperthermia, in common clinical MR imaging which applies RF frequencies between 64 and 128 MHz, the RF field distribution inside a patient is largely determined by the dielectric distribution of the anatomy. Modern MR imaging techniques allow measurement of the RF magnetic field component B 1+ making it possible to measure at high resolution the dielectric interaction of the RF field with the patient. Given these considerations, we propose to use MR imaging to verify the validity of our dielectric patient model used for SAR models of radiofrequency hyperthermia. The aim of this study was to investigate the feasibility of this concept by performing B 1+ measurements and simulations on cylindrical split phantoms consisting of materials with dielectric properties similar to human tissue types. Important topics of investigation were the accuracy and sensitivity of B 1+ measurements and the validity of the electric model of the MR body coil. The measurements were performed on a clinical 1.5 T MR scanner with its quadrature body coil operating at 64 MHz. It was shown that even small B 1+ variations of 2 to 5% could be measured reliably in the phantom experiments. An electrical model of the transmit coil was implemented on our FDTD-based hyperthermia treatment planning platform and the RF field distributions were calculated assuming an idealized quadrature current distribution in the coil. A quantitatively good correlation between measurements and simulations was found for phantoms consisting of water and oil, while highly conductive phantoms show considerable deviations. However, assuming linear excitation for these conductive phantoms resulted in good correspondence. As an explanation it is suggested that the coil is being detuned due to the inductive nature of the conductive phantoms, breaking up the phase difference of

  3. Prospective comparison of MR imaging (1.5 T) and CT detection of small intracranial metastases

    International Nuclear Information System (INIS)

    Dowd, C.F.; Dillon, W.P.; Laxer, K.; Norman, D.; Newton, T.H.

    1987-01-01

    Prior studies indicate lack of MR imaging sensitivity in the evaluation of intractable seizure patients. The authors reviewed MR imaging studies of 15 patients with intractable seizures. High-quality thin-section multiplanar images were obtained with electrocardiographic gating and/or flow compensation techniques and a 1.5-T General Electric Signa unit. Correlation with intracranial electro-encephalography (EEG), CT, and pathology was obtained in all patients. Abnormalities on MR imaging were detected in all but one patient. Pathology revealed MTS in 12 of 15 patients. Other entities included heterotopias and cavernous angiomas. The authors' study indicates that high-resolution, flow-compensated MR imaging is quite sensitive for localization of eleptogenic structural abnormalities and complements EEG

  4. Identification and characterization of a highly variable region in mitochondrial genomes of fusarium species and analysis of power generation from microbial fuel cells

    Science.gov (United States)

    Hamzah, Haider Mousa

    In the microbial fuel cell (MFC) project, power generation from Shewanella oneidensis MR-1 was analyzed looking for a novel system for both energy generation and sustainability. The results suggest the possibility of generating electricity from different organic substances, which include agricultural and industrial by-products. Shewanella oneidensis MR-1 generates usable electrons at 30°C using both submerged and solid state cultures. In the MFC biocathode experiment, most of the CO2 generated at the anodic chamber was converted into bicarbonate due the activity of carbonic anhydrase (CA) of the Gluconobacter sp.33 strain. These findings demonstrate the possibility of generation of electricity while at the same time allowing the biomimetic sequestration of CO2 using bacterial CA. In the mitochondrial genomes project, the filamentous fungal species Fusarium oxysporum was used as a model. This species causes wilt of several important agricultural crops. A previous study revealed that a highly variable region (HVR) in the mitochondrial DNA (mtDNA) of three species of Fusarium contained a large, variable unidentified open reading frame (LV-uORF). Using specific primers for two regions of the LV-uORF, six strains were found to contain the ORF by PCR and database searches identified 18 other strains outside of the Fusarium oxysporum species complex. The LV-uORF was also identified in three isolates of the F. oxysporum species complex. Interestingly, several F. oxysporum isolates lack the LV-uORF and instead contain 13 ORFs in the HVR, nine of which are unidentified. The high GC content and codon usage of the LV-uORF indicate that it did not co-evolve with other mt genes and was horizontally acquired and was introduced to the Fusarium lineage prior to speciation. The nonsynonymous/synonymous (dN/dS) ratio of the LV-uORFs (0.43) suggests it is under purifying selection and the putative polypeptide is predicted to be located in the mitochondrial membrane. Growth assays

  5. Evaluation of intracranial hemorrhage with high field MR Imaging (1. 5T)

    Energy Technology Data Exchange (ETDEWEB)

    Campodonico, F; Brienza, G; Cotroneo, E; Fabbrini, G

    1989-01-01

    Fifty-two patients were studied with high-field Magnetic Resonance imaging (1.5T), with T1- and T2-weighted spin-echo pulse sequences. The study was aimed at assessing the efficacy of MR imaging in the evaluation of intracranical hematomas. Characteristic intensity patterns were observed in the evolution of the hematomas, were observed. In 35 sub-acute hematomas, peripheral hyperintensity could be observed on T1- and T2. weighted pulse sequences. This hyper intensity eventually fills in the hematoma in the chronic stage. In 17 chronic hematomas, a peripheral hypointense ring due to hemosidering deposits was seen on T1- and T2- weighted scans. The authors conclude that high field MR imaging is a very sensible diagnostic method in the evaluation of sub-acute and chronic hematomas. 18 refs.

  6. MR imaging of septic sacroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Stuerzenbecher, A.; Hamm, B.; Bollow, M. [Humboldt-Universitaet, Berlin (DD). Bereich Medizin (Charite); Braun, J. [Freie Univ. Berlin (Germany). Universitaetsklinikum Benjamin Franklin; Paris, S. [Unfallkrankenhaus Berlin (Germany). Dept. of Radiology; Biedermann, T. [Krankenhaus Berlin-Buch (Germany). II. Kinderklinik

    2000-08-01

    Objective. To investigate the diagnostic value of magnetic resonance (MR) imaging in detecting septic sacroiliitis and to determine whether the MR characteristics allow this entity to be differentiated from sacroiliitis in spondylarthropathy (SpA).Patients and design. The imaging findings of 11 patients with septic sacroiliitis were retrospectively analyzed by two experienced radiologists. Radiographic surveys of the pelvis as well as computed tomography (CT) and MR images of the sacroiliac joints were available in all cases. Seven of the patients additionally underwent a follow-up MR examination. The MR imaging protocol comprised combinations of coronal and transverse T1-weighted spin-echo (SE) or fast SE sequences, T2-weighted gradient-echo (GE) sequences and short tau inversion recovery sequence (STIR) sequences as well as dynamic contrast- enhanced T1-weighted acquisitions.Results. Three patients with a short disease history showed anterior and/or posterior subperiosteal infiltrations (''lava cleft phenomenon''), transcapsular infiltrations of juxta-articular muscle layers, which obscured the fasciae, and periarticular bone marrow edema. The eight patients with more advanced stages of sacroiliitis additionally showed abscess formation, sequestration, and erosion. At follow-up MR examination (n=7) under systemic antibiotic treatment, the morphologic characteristics showed progression (n=1), regression (n=4), unchanged findings (n=1), or a mixed response (n=1). Clinical improvement precedes resolution of the MR findings.Conclusions. Anterior and/or posterior subperiosteal infiltrations and transcapsular infiltrations of juxta-articular muscle layers were depicted in all patients. These MR imaging findings are characteristic of septic sacroiliitis and may be used to differentiate this entity from sacroiliitis in SpA. (orig.)

  7. MR investigation of recurrent cholesteatomas

    Energy Technology Data Exchange (ETDEWEB)

    Doyon, D.; Chan, K.Y.; Attia, M.; Halimi, P.; Sigal, R.; Bobin, S.; Sterkers, J.M.

    1989-03-01

    Nine cases of recurrent petrous cholesteatomas have been studied by a 1.5 T MR unit. Gadolinium was injected in 1 case. In all cases, comparison between MR, CT and clinical findings were made. MR allows for accurate topographic study and assessment of cholesteatomas extension, in particular in the posterior fossa and skull base. Relationships with the internal carotid artery and the jugular vein are clearly depicted.

  8. Detection and staging of chondromalacia patellae: relative efficacies of conventional MR imaging, MR arthrography, and CT arthrography.

    Science.gov (United States)

    Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F

    1994-09-01

    Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton

  9. MR microscopy of articular cartilage at 1.5 T: orientation and site dependence of laminar structures

    International Nuclear Information System (INIS)

    Yoshioka, Hiroshi; Anno, Izumi; Echigo, Junko; Itai, Yuji; Haishi, Tomoyuki; Uematsu, Takaaki; Matsuda, Yoshimasa; Kose, Katsumi; Lang, Philipp

    2002-01-01

    Abstract Objective. To evaluate MR microscopic images of normal-appearing porcine hyaline cartilage (n=15) in vitro obtained with an MR microscope using an independent console system (MRMICS) at 1.5 T.Design and results. The MRMICS is a portable imaging system consisting of a radiofrequency system, gradient power supplies and a personal computer. The images from the MRMICS showed a laminar structure of porcine cartilage similar to the structure demonstrated with other MR imaging techniques. The laminar structures of the articular cartilage, were, however heterogeneous in respect of signal intensity and thickness, which varied according to the site resected. The MR laminar appearance was most comparable to the staining with Masson's trichrome for collagen.Conclusion. MRMICS is a useful add-on system for obtaining microscopic MR images of articular cartilage in vitro. (orig.)

  10. k-t SENSE-accelerated Myocardial Perfusion MR Imaging at 3.0 Tesla - comparison with 1.5 Tesla

    Science.gov (United States)

    Plein, Sven; Schwitter, Juerg; Suerder, Daniel; Greenwood, John P.; Boesiger, Peter; Kozerke, Sebastian

    2008-01-01

    Purpose To determine the feasibility and diagnostic accuracy of high spatial resolution myocardial perfusion MR at 3.0 Tesla using k-space and time domain undersampling with sensitivity encoding (k-t SENSE). Materials and Methods The study was reviewed and approved by the local ethic review board. k-t SENSE perfusion MR was performed at 1.5 Tesla and 3.0 Tesla (saturation recovery gradient echo pulse sequence, repetition time/echo time 3.0ms/1.0ms, flip angle 15°, 5x k-t SENSE acceleration, spatial resolution 1.3×1.3×10mm3). Fourteen volunteers were studied at rest and 37 patients during adenosine stress. In volunteers, comparison was also made with standard-resolution (2.5×2.5×10mm3) 2x SENSE perfusion MR at 3.0 Tesla. Image quality, artifact scores, signal-to-noise ratios (SNR) and contrast-enhancement ratios (CER) were derived. In patients, diagnostic accuracy of visual analysis to detect >50% diameter stenosis on quantitative coronary angiography was determined by receiver-operator-characteristics (ROC). Results In volunteers, image quality and artifact scores were similar for 3.0 Tesla and 1.5 Tesla, while SNR was higher (11.6 vs. 5.6) and CER lower (1.1 vs. 1.5, p=0.012) at 3.0 Tesla. Compared with standard-resolution perfusion MR, image quality was higher for k-t SENSE (3.6 vs. 3.1, p=0.04), endocardial dark rim artifacts were reduced (artifact thickness 1.6mm vs. 2.4mm, pTesla and 1.5 Tesla, respectively. Conclusions k-t SENSE accelerated high-resolution perfusion MR at 3.0 Tesla is feasible with similar artifacts and diagnostic accuracy as at 1.5 Tesla. Compared with standard-resolution perfusion MR, image quality is improved and artifacts are reduced. PMID:18936311

  11. Conspicuity of diffuse axonal injury lesions on diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Kinoshita, Toshibumi; Moritani, Toshio; Hiwatashi, Akio; Wang, Henry Z.; Shrier, David A.; Numaguchi, Yuji; Westesson, Per-Lennart A.

    2005-01-01

    Objective: (1) To detect diffuse axonal injury (DAI) lesions by diffusion-weighted imaging (DWI), as compared with fluid-attenuated inversion recovery (FLAIR) imaging and (2) to evaluate hemorrhagic DAI lesions by b 0 images obtained from DWI, as compared with gradient-echo (GRE) imaging. Methods: We reviewed MR images of 36 patients with a diagnosis of DAI. MR imaging was performed 20 h to 14 days (mean, 3.7 days) after traumatic brain injury. We evaluated: (1) conspicuity of lesions on DWI and FLAIR and (2) conspicuity of hemorrhage in DAI lesions on b 0 images and GRE imaging. Results: DWI clearly depicted high-signal DAI lesions. The sensitivity of DWI to lesional conspicuity in DAI lesions was almost equal to that of FLAIR. The sensitivity of b 0 images to identification of hemorrhagic DAI lesions was inferior to that of GRE. Conclusion: DWI is as useful as FLAIR in detecting DAI lesions. GRE imaging is still the superior tool for the evaluation of hemorrhagic DAI

  12. Metabolite ratios in 1H MR spectroscopic imaging of the prostate

    NARCIS (Netherlands)

    Kobus, T.; Wright, A.J.; Weiland, E.; Heerschap, A.; Scheenen, T.W.J.

    2015-01-01

    In (1)H MR spectroscopic imaging ((1)H-MRSI) of the prostate the spatial distribution of the signal levels of the metabolites choline, creatine, polyamines, and citrate are assessed. The ratio of choline (plus spermine as the main polyamine) plus creatine over citrate [(Cho+(Spm+)Cr)/Cit] is derived

  13. Pre- and postoperative MR imaging of craniopharyngiomas

    Energy Technology Data Exchange (ETDEWEB)

    Hald, J.K. [Rijkshospitalet, Oslo (Norway). Dept. of Radiology; Eldevik, O.P. [Rijkshospitalet, Oslo (Norway). Dept. of Neurosurgery; Quint, D.J. [Rijkshospitalet, Oslo (Norway). Dept. of Neurosurgery; Chandler, W.F. [Univ. of Michigan Hospital, Ann Arbor, MI (United States). Dept. of Radiology; Kollevold, T. [Univ. of Michigan Hospital, Ann Arbor, MI (United States). Dept. of Neurosurgery

    1996-09-01

    Purpose: To compare the pre- and postoperative MR appearance of craniopharyngiomas with respect to lesion size, tumour morphology and identification of surrounding normal structures. Material and Methods: MR images obtained prior to and following craniopharyngioma resection were evaluated retrospectively in 10 patients. Tumour signal charcteristics, size and extension with particular reference to the optic chiasm, the pituitary gland, the pituitary stalk and the third ventricle were evaluated. Results: Following surgery, tumour volume was reduced in all patients. In 6 patients there was further tumour volume reduction between the first and second postoperative images. Two of these patients received radiation therapy between the 2 postoperative studies, while 4 had no adjuvant treatment to the surgical intervention. There was improved visualization of the optic chiasm, in 3, the pituitary stalk in one, and the third ventricle in 9 of the 10 patients. The pituitary gland was identified preoperatively only in one patient, postoperatively only in another, pre- and postoperatively in 5, and neither pre- nor postoperatively in 3 patients. In 3 patients MR imaging 0-7 days postoperatively identified tumour remnants not seen at the end of the surgical procedure. The signal intensities of solid and cystic tumour components were stable from pre- to the first postoperative MR images. Optic tract increased signal prior to surgery was gone 28 days postoperatively in one patient, but persisted on the left side for 197 days after surgery in another. Conclusion: Postoperative MR imaging of craniopharyngiomas demonstrated tumour volume reduction and tumour remnants not seen at surgery. Early postoperative MR imaging of craniopharyngiomas may overestimate the size of residual tumour. Improved visualization of peritumoral structures may be achieved. (orig.).

  14. Intra-articular ganglion cysts of the knee: clinical and MR imaging features

    International Nuclear Information System (INIS)

    Kim, M.G.; Cho, W.H.; Kim, B.H.; Choi, J.A.; Lee, N.J.; Chung, K.B.; Choi, Y.S.; Cho, S.B.; Lim, H.C.

    2001-01-01

    The purpose of this study was to present clinical and MR imaging features of intra-articular ganglion cysts of the knee. Retrospective review of 1685 consecutive medical records and MR examinations of the knee performed at three imaging centers allowed identification of 20 patients (13 men and 7 women; mean age 35 years), in whom evidence of intra-articular ganglion cyst was seen. Of the 20 ganglion cysts, 5 were found in the infrapatellar fat pad, 10 arose from the posterior cruciate ligament, and 5 from the anterior cruciate ligament. Three of five patients with ganglion cyst in the infrapatellar fat pad had a palpable mass. In 7 of 15 patients with ganglion cyst in the intercondylar notch, exacerbation of pain occurred in a squatting position. On four MR arthrographies, ganglion cysts were an intra-articular round, lobulated, low signal intensity lesion. Five cases of fat-suppressed contrast-enhanced T1-weighted SE images demonstrated peripheral thin rim enhancement. The clinical presentation of intra-articular ganglion cyst is varied according to its intra-articular location. The MR appearance of intra-articular ganglion cyst is characteristic and usually associated with the cruciate ligament or the infrapatellar fat pad. Magnetic resonance arthrography has no definite advantage over conventional MR in the evaluation of the lesion. For intra-articular ganglion cyst in the infrapatellar fat pad, fat-suppressed contrast-enhanced MR imaging could be useful, because a thin, rim-enhancing feature of intra-articular ganglion cyst allows it to be distinguished from synovial hemangioma and synovial sarcoma. (orig.)

  15. MR investigation of recurrent cholesteatomas

    International Nuclear Information System (INIS)

    Doyon, D.; Chan, K.Y.; Attia, M.; Halimi, P.; Sigal, R.; Bobin, S.; Sterkers, J.M.

    1989-01-01

    Nine cases of recurrent petrous cholesteatomas have been studied by a 1.5 T MR unit. Gadolinium was injected in 1 case. In all cases, comparison between MR, CT and clinical findings were made. MR allows for accurate topographic study and assessment of cholesteatomas extension, in particular in the posterior fossa and skull base. Relationships with the internal carotid artery and the jugular vein are clearly depicted [fr

  16. Localized proton 1H MR spectroscopy in different regions of the human brain

    International Nuclear Information System (INIS)

    Fang Hong; Guo Qinglin; Zhang Guixiang

    1997-01-01

    To study the 1 H MR spectrum of normal human brain and the concentration and distribution of main metabolites using 1 H MR spectroscopy eighteen healthy human brains were examined by conventional 1.5 T MRI system. Volume of interest (VOI) included temporal lobe (mainly gray matter), thalamus, cerebellum as well as white matter. Proton MR spectroscopy can detect a variety of metabolites in human brain in vivo. The main detectable metabolites were N-acetyl-aspartate (NAA: at 2.02 ppm), cholineontaining compounds (Cho: at 3.2 ppm), phospho-creating and creatine (PCr + Cr: at 3.0 ppm), glutamine and glutamate (Gln + Glu: at 2.34-2.45 ppm), lipids (Lip: at 1.0 ppm) and lactate (Lac: at 1.3 ppm). the metabolite concentration varied in different parts of the brain. The relative signal intensity calculation showed that: NAA/Cho ratio is the highest in gray matter and lowest in cerebellun. Cr/Cho is the highest in cerebellum and lowest in white matter. The assumed creatine concentration is 10 mmol/L for gray matter and cerebellum, 11 mmol/L for white matter and thalanmus, the absolute concentration of NAA in the brain is about 13-23 mmol/L, and is higher in gray matter than in cerebellum and thalamus. Proton MR spectroscopy is a new noninvasive method which can be used to detect a number of chemical compounds pertaining to energy metabolism, free amino acids, fatty acids and neurotransmitters in the brain. It is useful to assess the cerebral biochemical changes in vivo both in healthy subjects and in patients with various brain disease

  17. MR1-restricted MAIT cells display ligand discrimination and pathogen selectivity through distinct T cell receptor usage

    DEFF Research Database (Denmark)

    Gold, Marielle C.; McLaren, James E.; Reistetter, Joseph A.

    2014-01-01

    Mucosal-associated invariant T (MAIT) cells express a semi-invariant T cell receptor (TCR) that detects microbial metabolites presented by the nonpolymorphic major histocompatibility complex (MHC)-like molecule MR1. The highly conserved nature of MR1 in conjunction with biased MAIT TCRα chain usa...

  18. MR imaging of prostate cancer; MR-Tomographie des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A. [Radiologisches Zentrum Muenchen-Pasing (Germany); Mueller-Lisse, U.G. [Institut fuer Klinische Radiologie, Universitaet Muenchen (Germany); Massmann, J. [Gemeinschaftspraxis Pathologie, Muenchen (Germany)

    2003-06-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [German] Der Diagnostik des Prostatakarzinoms kommt wegen seiner hohen Inzidenz und den verbesserten stadienadaptierten Therapiemoeglichkeiten eine grosse Bedeutung zu. Dabei spielen bildgebende Verfahren bei den klinisch oft unzureichend diagnostizierbaren Faellen eine wesentliche Rolle fuer die praetherapeutische

  19. Fast high-resolution MR imaging using the snapshot-FLASH MR sequence

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Henrich, D.; Duhmke, E.

    1990-01-01

    Snapshot, fast low-angle short (FLASH) MR imaging using an accelerated FLASH-MR sequence provides MR images with measuring times far below 1 second. The short TE of this sequence prevents susceptibility artifacts in gradient-echo imaging. In this paper variations of the sequence are shown that provide high resolution images with T1-weighted IR, T2-weighted SE, and chemical shift (CHESS) contrast sequences. METHODS AND MATERIALS: A whole-body 2-T system (Bruker-Medizintechnik) were used in combination with a 60-cm gradient system (providing gradient strength of 5 mT/m) to study healthy volunteers. The measuring time for a 256 x 256 image matrix was 800 msec. This sequence has been used in combination with T1-weighted IR, T2-weighted SE, and CHESS variations

  20. Contrast-enhanced dynamic MR imaging in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Koenig, H.; Sieper, J.; Wolf, K.J.

    1989-01-01

    This paper reports on a study for the identification of different pannus formations. Twenty patients with advanced rheumatoid arthritis of the knee joint were examined with MR imaging primary to surgery. The authors used a 1.5-T Magnetom unit, a circular surface coil for signal detection, 0.1 mmol/kg of Gd-DTPA given as a bolus injection, fast low-angle shot (FLASH) sequence (TR, 30 msec; TE, 10 msec; 128 x 128 matrix; excitation angle, 70 degrees) repeated 30 times within 120 seconds, and a T1-weighted spin-echo sequence (Tr, 500 msec; TE, 22 msec) before and 2 minutes after contrast medium injection. Enhancement of pannus and joint effusion has been measured and standardized to muscle tissue

  1. MR microscopy of articular cartilage at 1.5 T: orientation and site dependence of laminar structures

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Hiroshi; Anno, Izumi; Echigo, Junko; Itai, Yuji [Department of Radiology, Institute of Clinical Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575 (Japan); Haishi, Tomoyuki; Uematsu, Takaaki; Matsuda, Yoshimasa; Kose, Katsumi [Institute of Applied Physics, University of Tsukuba, Tsukuba (Japan); Lang, Philipp [Department of Radiology, Brigham and Women' s Hospital, Boston, Massachusetts (United States)

    2002-09-01

    Abstract Objective. To evaluate MR microscopic images of normal-appearing porcine hyaline cartilage (n=15) in vitro obtained with an MR microscope using an independent console system (MRMICS) at 1.5 T.Design and results. The MRMICS is a portable imaging system consisting of a radiofrequency system, gradient power supplies and a personal computer. The images from the MRMICS showed a laminar structure of porcine cartilage similar to the structure demonstrated with other MR imaging techniques. The laminar structures of the articular cartilage, were, however heterogeneous in respect of signal intensity and thickness, which varied according to the site resected. The MR laminar appearance was most comparable to the staining with Masson's trichrome for collagen.Conclusion. MRMICS is a useful add-on system for obtaining microscopic MR images of articular cartilage in vitro. (orig.)

  2. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients—Current state of image quality

    International Nuclear Information System (INIS)

    Schwenzer, N.F.; Stegger, L.; Bisdas, S.; Schraml, C.; Kolb, A.; Boss, A.; Müller, M.

    2012-01-01

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [ 18 F]-FDG, [ 11 C]-methionine or [ 68 Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [ 11 C]-methionine and [ 68 Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 ± 0.54; FLAIR: 1.38 ± 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 ± 0.69; ASL: 1.10 ± 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [ 11 C]-methionine; additional lesions were found in 2/8 [ 68 Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 ± 2.2% vs. 0.9 ± 3.6%; mean ratio (frontal/parieto-occipital) 0.93 ± 0.08 vs. 0.96 ± 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance of PET results between PET/MR and PET

  3. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients-Current state of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schwenzer, N.F., E-mail: nina.schwenzer@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Stegger, L., E-mail: stegger@gmx.net [Department of Nuclear Medicine and European Institute for Molecular Imaging, University of Muenster, Muenster (Germany); Bisdas, S., E-mail: sbisdas@gmail.com [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Schraml, C., E-mail: christina.schraml@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de [Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Preclinical Imaging and Radiopharmacy, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Boss, A., E-mail: Andreas.Boss@usz.ch [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Institute of Diagnostic and Interventional Radiology, University Hospital Zuerich, Zuerich (Switzerland); Mueller, M., E-mail: mark.mueller@med.uni-tuebingen.de [Department of Nuclear Medicine, Eberhard-Karls University Tuebingen, Tuebingen (Germany); and others

    2012-11-15

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [{sup 18}F]-FDG, [{sup 11}C]-methionine or [{sup 68}Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [{sup 11}C]-methionine and [{sup 68}Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 {+-} 0.54; FLAIR: 1.38 {+-} 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 {+-} 0.69; ASL: 1.10 {+-} 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [{sup 11}C]-methionine; additional lesions were found in 2/8 [{sup 68}Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 {+-} 2.2% vs. 0.9 {+-} 3.6%; mean ratio (frontal/parieto-occipital) 0.93 {+-} 0.08 vs. 0.96 {+-} 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance

  4. Rectal cancer: assessment of complete response to preoperative combined radiation therapy with chemotherapy--conventional MR volumetry versus diffusion-weighted MR imaging.

    Science.gov (United States)

    Curvo-Semedo, Luís; Lambregts, Doenja M J; Maas, Monique; Thywissen, Thomas; Mehsen, Rana T; Lammering, Guido; Beets, Geerard L; Caseiro-Alves, Filipe; Beets-Tan, Regina G H

    2011-09-01

    To determine diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging for assessment of complete tumor response (CR) after combined radiation therapy with chemotherapy (CRT) in patients with locally advanced rectal cancer (LARC) by means of volumetric signal intensity measurements and apparent diffusion coefficient (ADC) measurements and to compare the performance of DW imaging with that of T2-weighted MR volumetry. A retrospective analysis of 50 patients with LARC, for whom clinical and imaging data were retrieved from a previous imaging study approved by the local institutional ethical committee and for which all patients provided informed consent, was conducted. Patients underwent pre- and post-CRT standard T2-weighted MR and DW MR. Two independent readers placed free-hand regions of interest (ROIs) in each tumor-containing section on both data sets to determine pre- and post-CRT tumor volumes and tumor volume reduction rates (volume). ROIs were copied to an ADC map to calculate tumor ADCs. Histopathologic findings were the standard of reference. Receiver operating characteristic (ROC) curves were generated to compare performance of T2-weighted and DW MR volumetry and ADC. The intraclass correlation coefficient (ICC) was used to evaluate interobserver variability and the correlation between T2-weighted and DW MR volumetry. Areas under the ROC curve (AUCs) for identification of a CR that was based on pre-CRT volume, post-CRT volume, and volume, respectively, were 0.57, 0.70, and 0.84 for T2-weighted MR versus 0.63, 0.93, and 0.92 for DW MR volumetry (P = .15, .02, .42). Pre- and post-CRT ADC and ADC AUCs were 0.55, 0.54, and 0.51, respectively. Interobserver agreement was excellent for all pre-CRT measurements (ICC, 0.91-0.96) versus good (ICC, 0.61-0.79) for post-CRT measurements. ICC between T2-weighted and DW MR volumetry was excellent (0.97) for pre-CRT measurements versus fair (0.25) for post-CRT measurements. Post-CRT DW MR

  5. 3.0 T conventional hip MR and hip MR arthrography for the acetabular labral tears confirmed by arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Chun-Yan [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Wang, Jian-Quan [Department of Sports Medicine, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191,PR China (China); Zheng, Zhuo-Zhao, E-mail: zzhuozhao@aliyun.com [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Ren, A.-Hong [Department of Radiology, Beijing Daxing Hospital, 26 West Huangcun Road, Daxing District, Beijing 102600 (China)

    2014-10-15

    Highlights: • MR is the preferred imaging modality for diagnosing acetabular labral tears. • The diagnostic performance of MR arthrography are superior than conventional hip MR. • The hip MR arthrography is recommended for diagnosing acetabular labral lesions. - Abstract: Objective: To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears. Methods: 90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy. Results: 59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05). Conclusion: Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.

  6. Diagnosing lung nodules on oncologic MR/PET imaging: Comparison of fast T1-weighted sequences and influence of image acquisition in inspiration and expiration breath-hold

    Energy Technology Data Exchange (ETDEWEB)

    Schwenzer, Nina F.; Seith, Ferdinand; Gatidis, Sergios; Brendle, Cornelia; Schmidt, Holger; Pfannenberg, Christina A; LaFougère, Christian; Nikolaou, Konstantin; Schraml, Christina [University Hospital of Tuebingen, Tuebingen (Germany)

    2016-09-15

    First, to investigate the diagnostic performance of fast T1-weighted sequences for lung nodule evaluation in oncologic magnetic resonance (MR)/positron emission tomography (PET). Second, to evaluate the influence of image acquisition in inspiration and expiration breath-hold on diagnostic performance. The study was approved by the local Institutional Review Board. PET/CT and MR/PET of 44 cancer patients were evaluated by 2 readers. PET/CT included lung computed tomography (CT) scans in inspiration and expiration (CTin, CTex). MR/PET included Dixon sequence for attenuation correction and fast T1-weighted volumetric interpolated breath-hold examination (VIBE) sequences (volume interpolated breath-hold examination acquired in inspiration [VIBEin], volume interpolated breath-hold examination acquired in expiration [VIBEex]). Diagnostic performance was analyzed for lesion-, lobe-, and size-dependence. Diagnostic confidence was evaluated (4-point Likert-scale; 1 = high). Jackknife alternative free-response receiver-operating characteristic (JAFROC) analysis was performed. Seventy-six pulmonary lesions were evaluated. Lesion-based detection rates were: CTex, 77.6%; VIBEin, 53.3%; VIBEex, 51.3%; and Dixon, 22.4%. Lobe-based detection rates were: CTex, 89.6%; VIBEin, 58.3%; VIBEex, 60.4%; and Dixon, 31.3%. In contrast to CT, inspiration versus expiration did not alter diagnostic performance in VIBE sequences. Diagnostic confidence was best for VIBEin and CTex and decreased in VIBEex and Dixon (1.2 ± 0.6; 1.2 ± 0.7; 1.5 ± 0.9; 1.7 ± 1.1, respectively). The JAFROC figure-of-merit of Dixon was significantly lower. All patients with malignant lesions were identified by CTex, VIBEin, and VIBEex, while 3 patients were false-negative in Dixon. Fast T1-weighted VIBE sequences allow for identification of patients with malignant pulmonary lesions. The Dixon sequence is not recommended for lung nodule evaluation in oncologic MR/PET patients. In contrast to CT, inspiration versus

  7. Diagnosing Lung Nodules on Oncologic MR/PET Imaging: Comparison of Fast T1-Weighted Sequences and Influence of Image Acquisition in Inspiration and Expiration Breath-Hold

    Energy Technology Data Exchange (ETDEWEB)

    Schwenzer, Nina F.; Seith, Ferdinand; Gatidis, Sergios [Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen 72076 (Germany); Brendle, Cornelia [Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen 72076 (Germany); Department of Diagnostic and Interventional Neuroradiology, University Hospital of Tuebingen, Tuebingen 72076 (Germany); Schmidt, Holger; Pfannenberg, Christina A. [Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen 72076 (Germany); Fougère, Christian la [Department of Nuclear Medicine, University Hospital of Tuebingen, Tuebingen 72076 (Germany); Nikolaou, Konstantin; Schraml, Christina [Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen 72076 (Germany)

    2016-11-01

    First, to investigate the diagnostic performance of fast T1-weighted sequences for lung nodule evaluation in oncologic magnetic resonance (MR)/positron emission tomography (PET). Second, to evaluate the influence of image acquisition in inspiration and expiration breath-hold on diagnostic performance. The study was approved by the local Institutional Review Board. PET/CT and MR/PET of 44 cancer patients were evaluated by 2 readers. PET/CT included lung computed tomography (CT) scans in inspiration and expiration (CTin, CTex). MR/PET included Dixon sequence for attenuation correction and fast T1-weighted volumetric interpolated breath-hold examination (VIBE) sequences (volume interpolated breath-hold examination acquired in inspiration [VIBEin], volume interpolated breath-hold examination acquired in expiration [VIBEex]). Diagnostic performance was analyzed for lesion-, lobe-, and size-dependence. Diagnostic confidence was evaluated (4-point Likert-scale; 1 = high). Jackknife alternative free-response receiver-operating characteristic (JAFROC) analysis was performed. Seventy-six pulmonary lesions were evaluated. Lesion-based detection rates were: CTex, 77.6%; VIBEin, 53.3%; VIBEex, 51.3%; and Dixon, 22.4%. Lobe-based detection rates were: CTex, 89.6%; VIBEin, 58.3%; VIBEex, 60.4%; and Dixon, 31.3%. In contrast to CT, inspiration versus expiration did not alter diagnostic performance in VIBE sequences. Diagnostic confidence was best for VIBEin and CTex and decreased in VIBEex and Dixon (1.2 ± 0.6; 1.2 ± 0.7; 1.5 ± 0.9; 1.7 ± 1.1, respectively). The JAFROC figure-of-merit of Dixon was significantly lower. All patients with malignant lesions were identified by CTex, VIBEin, and VIBEex, while 3 patients were false-negative in Dixon. Fast T1-weighted VIBE sequences allow for identification of patients with malignant pulmonary lesions. The Dixon sequence is not recommended for lung nodule evaluation in oncologic MR/PET patients. In contrast to CT, inspiration versus

  8. MR of head and neck hemangiomas

    International Nuclear Information System (INIS)

    Bilaniuk, L.T.; Zimmerman, R.A.; Gusnard, D.A.

    1990-01-01

    This paper defines the MR characteristics of head and neck hemangiomas and to evaluate the role of MR in their diagnosis and management. Eighteen pediatric and young adult patients with head and neck hemangiomas (six neck, six face, three eyelid, two scalp, and one parotid) underwent high-field-strength 1.5-T MR imaging. Conventional spin-echo sequences with T1 and T2 weighting were performed. In addition, one-third of patients underwent MR angiography and gadolinium enhancement. The hemangiomas were isointense to muscle on T1-weighted images and hyperintense on proton-density and T2-weighted images

  9. MR imaging in chronic epicondylitis humeri radialis at 1.0 T: is Gd-DTPA administration useful?

    International Nuclear Information System (INIS)

    Herber, S.; Kalden, P.; Kreitner, K.-F.; Thelen, M.

    2001-01-01

    Purpose: Evaluation of the diagnostic value and confidence of contrast-enhanced MR imaging in patients with lateral epicondylitis in comparison to clinical diagnosis. Material and Methods: 42 consecutive patients with clinically proven chronic lateral epicondylitis and 10 elbow joints of healthy controls have been examined on a 1.0 T MR-unit. Criteria for inclusion in the prospective study were: persistant pain and a failed conservative therapy. The MR protocol included STIR sequence, a native, T 2 -weighted, fat-supressed TSE sequence, and a flash-2-D sequence. Also, fat-supressed, T 1 -weighted SE sequences before and after administration of Gd-DTPA contrast media have been recorded. Results: In 39/42 patients the STIR sequence showed an increased SI of the common extensor tendom. Increased MR signal of the lateral collateral ligament combined with a thickening and a partial rupture or a full thickness tear have been observed in 15/42 cases. A bone marrow edema at the lateral epicondylus was noticed in 6 of the studied patients and a joint effusion in 18/42 patients. After administration of contrast media we noticed an average increase of SI by about 150%. However, enhanced MR imaging did not provide additional information. Conclusion: In MR imaging of chronic epicondylitis administration of gadolinium-DTPA does not provide additional information. (orig.) [de

  10. Design of a multimodal ({sup 1}H/{sup 23}Na MR/CT) anthropomorphic thorax phantom

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Wiebke; Lietzmann, Florian; Schad, Lothar R.; Zoellner, Frank G. [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine

    2017-08-01

    This work proposes a modular, anthropomorphic MR and CT thorax phantom that enables the comparison of experimental studies for quantitative evaluation of deformable, multimodal image registration algorithms and realistic multi-nuclear MR imaging techniques. A human thorax phantom was developed with insertable modules representing lung, liver, ribs and additional tracking spheres. The quality of human tissue mimicking characteristics was evaluated for {sup 1}H and {sup 23}Na MR as well as CT imaging. The position of landmarks in the lung lobes was tracked during CT image acquisition at several positions during breathing cycles. {sup 1}H MR measurements of the liver were repeated after seven months to determine long term stability. The modules possess HU, T{sub 1} and T{sub 2} values comparable to human tissues (lung module: -756 ± 148 HU, artificial ribs: 218 ± 56 HU (low CaCO{sub 3} concentration) and 339 ± 121 (high CaCO{sub 3} concentration), liver module: T{sub 1} = 790 ± 28 ms, T{sub 2} = 65 ± 1 ms). Motion analysis showed that the landmarks in the lung lobes follow a 3D trajectory similar to human breathing motion. The tracking spheres are well detectable in both CT and MRI. The parameters of the tracking spheres can be adjusted in the following ranges to result in a distinct signal: HU values from 150 to 900 HU, T{sub 1} relaxation time from 550 ms to 2000 ms, T{sub 2} relaxation time from 40 ms to 200 ms. The presented anthropomorphic multimodal thorax phantom fulfills the demands of a simple, inexpensive system with interchangeable components. In future, the modular design allows for complementing the present set up with additional modules focusing on specific research targets such as perfusion studies, {sup 23}Na MR quantification experiments and an increasing level of complexity for motion studies.

  11. MR imaging of neonatal cerebral hemorrhage at 1.5 T

    International Nuclear Information System (INIS)

    McArdle, C.B.; Mehta, S.D.; Kulkarni, M.V.; Keeney, S.A.; Adcock, E.W. III.

    1987-01-01

    Twenty-three intracerebral hemorrhages (ICH) were seen in 60 neonates. Both T1- weighted (spin-echo, repetition time/echo time = 600-800/20 msec) and heavily T2- weighted sequences (SE = 2,500/80, 160) were necessary for detecting hemorrhage. MR imaging failed to disclose seven of ten IVH because of an irregular and full choroid, seen on US. US failed to show six ICH because of their small size (≤0.5 cm) or peripheral site. Twelve extracerebral hemorrhages were missed on US, and only one of three was seen on CT. In five other cases there were signal features of hemosidering from earlier hemorrhage. MR imaging is the best modality for visualizing ICH because of its high sensitivity, specificity, and the persistence of hemorrhagic signal for weeks to months longer than on US or CT

  12. Investigating different mechanisms for biogenic selenite transformations: Geobacter sulfurreducens, Shewanella oneidensis and Veillonella atypica

    Science.gov (United States)

    Pearce, C.I.; Pattrick, R.A.D.; Law, N.; Charnock, J.M.; Coker, V.S.; Fellowes, J.W.; Oremland, R.S.; Lloyd, J.R.

    2009-01-01

    The metal-reducing bacteria Geobacter sulfurreducens, Shewanella oneidensis and Veillonella atypica, use different mechanisms to transform toxic, bioavailable sodium selenite to less toxic, non-mobile elemental selenium and then to selenide in anaerobic environments, offering the potential for in situ and ex situ bioremediation of contaminated soils, sediments, industrial effluents, and agricultural drainage waters. The products of these reductive transformations depend on both the organism involved and the reduction conditions employed, in terms of electron donor and exogenous extracellular redox mediator. The intermediary phase involves the precipitation of elemental selenium nanospheres and the potential role of proteins in the formation of these structures is discussed. The bionanomineral phases produced during these transformations, including both elemental selenium nanospheres and metal selenide nanoparticles, have catalytic, semiconducting and light-emitting properties, which may have unique applications in the realm of nanophotonics. This research offers the potential to combine remediation of contaminants with the development of environmentally friendly manufacturing pathways for novel bionanominerals. ?? 2009 Taylor & Francis.

  13. Prediction of pancreatic neuroendocrine tumour grade with MR imaging features: added value of diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lotfalizadeh, Emad; Vullierme, Marie-Pierre; Allaham, Wassim [University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); Ronot, Maxime; Vilgrain, Valerie [University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); University Paris Diderot, Paris (France); INSERM U1149, Centre de Recherche Biomedicale Bichat-Beaujon, CRB3, Paris (France); Wagner, Mathilde [University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); INSERM U1149, Centre de Recherche Biomedicale Bichat-Beaujon, CRB3, Paris (France); Cros, Jerome; Couvelard, Anne [University Paris Diderot, Paris (France); University Hospitals Paris Nord Val de Seine, Department of Pathology, Clichy, Hauts-de-Seine (France); Hentic, Olivia; Ruzniewski, Philippe [University Hospitals Paris Nord Val de Seine, Department of Gastroenterology, Clichy, Hauts-de-Seine (France)

    2017-04-15

    To evaluate the value of MR imaging including diffusion-weighted imaging (DWI) for the grading of pancreatic neuroendocrine tumours (pNET). Between 2006 and 2014, all resected pNETs with preoperative MR imaging including DWI were included. Tumour grading was based on the 2010 WHO classification. MR imaging features included size, T1-w, and T2-w signal intensity, enhancement pattern, apparent (ADC) and true diffusion (D) coefficients. One hundred and eight pNETs (mean 40 ± 33 mm) were evaluated in 94 patients (48 women, 51 %, mean age 52 ± 12). Fifty-five (51 %), 42 (39 %), and 11 (10 %) tumours were given the following grades (G): G1, G2, and G3. Mean ADC and D values were significantly lower as grade increased (ADC: 2.13 ± 0.70, 1.78 ± 0.72, and 0.86 ± 0.22 10{sup -3} mm{sup 2}/s, and D: 1.92 ± 0.70, 1.75 ± 0.74, and 0.82 ± 0.19 10{sup -3} mm{sup 2}/s G1, G2, and G3, all p < 0.001). A higher grade was associated with larger sized tumours (p < 0.001). The AUROC of ADC and D to differentiate G3 and G1-2 were 0.96 ± 0.02 and 0.95 ± 0.02. Optimal cut-off values for the identification of G3 were 1.19 10{sup -3} mm{sup 2}/s for ADC (sensitivity 100 %, specificity 92 %) and 1.04 10{sup -3} mm{sup 2}/s for D (sensitivity 82 %, specificity 92 %). Morphological/functional MRI features of pNETS depend on tumour grade. DWI is useful for the identification of high-grade tumours. (orig.)

  14. Hepatic Steatosis in Morbidly Obese Patients Undergoing Gastric Bypass Surgery: Assessment With Open-System 1H-MR Spectroscopy

    NARCIS (Netherlands)

    van Werven, Jochem R.; Schreuder, Tim C. M. A.; Aarts, Edo O.; Nederveen, Aart J.; Meijer, Jos W. R.; Berends, Frits J.; Janssen, Ignace M. C.; Mulder, Chris J.; Jansen, Peter L. M.; Stoker, Jaap

    2011-01-01

    The purpose of this study was to assess, with histopathologic control, the use of open-system 1-T (1)H MR spectroscopy for the evaluation of hepatic steatosis in morbidly obese patients undergoing gastric bypass surgery. Patients underwent (1)H MR spectroscopy (MRS) for the assessment of steatosis

  15. Evaluation of shoulder pathology: three-dimensional enhanced T1 high-resolution isotropic volume excitation MR vs two-dimensional fast spin echo T2 fat saturation MR.

    Science.gov (United States)

    Park, H J; Lee, S Y; Kim, M S; Choi, S H; Chung, E C; Kook, S H; Kim, E

    2015-03-01

    To evaluate the diagnostic accuracy of three-dimensional (3D) enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) shoulder MR for the detection of rotator cuff tears, labral lesions and calcific tendonitis of the rotator cuff in comparison with two-dimensional (2D) fast spin echo T2 fat saturation (FS) MR. This retrospective study included 73 patients who underwent shoulder MRI using the eTHRIVE technique. Shoulder MR images were interpreted separately by two radiologists. They evaluated anatomic identification and image quality of the shoulder joint on routine MRI sequences (axial and oblique coronal T2 FS images) and compared them with the reformatted eTHRIVE images. The images were scored on a four-point scale (0, poor; 1, questionable; 2, adequate; 3, excellent) according to the degree of homogeneous and sufficient fat saturation to penetrate bone and soft tissue, visualization of the glenoid labrum and distinction of the supraspinatus tendon (SST). The diagnostic accuracy of eTHRIVE images compared with routine MRI sequences was evaluated in the setting of rotator cuff tears, glenoid labral injuries and calcific tendonitis of the SST. Fat saturation scores for eTHRIVE were significantly higher than those of the T2 FS for both radiologists. The sensitivity and accuracy of the T2 FS in diagnosing rotor cuff tears were >90%, whereas sensitivity and accuracy of the eTHRIVE method were significantly lower. The sensitivity, specificity and accuracy of both images in diagnosing labral injuries and calcific tendonitis were similar and showed no significant differences. The specificity of both images for the diagnosis of labral injuries and calcific tendonitis was higher than the sensitivities. The accuracy of 3D eTHRIVE imaging was comparable to that of 2D FSE T2 FS for the diagnosis of glenoid labral injury and calcific tendonitis of SST. The 3D eTHRIVE technique was superior to 2D FSE T2 FS in terms of fat saturation. Overall, 3D eTHRIVE was inferior

  16. McCune-Albright syndrome: radiological and MR findings.

    Science.gov (United States)

    Yongjing, G; Huawei, L; Zilai, P; Bei, D; Hao, J; Kemin, C

    2001-01-01

    McCune-Albright syndrome (MAS) is a non-inherited disorder due to the GNAS1 gene mutation. The syndrome is characterized with the triad of polyostotic fibrous dysplasia, pigmented skin lesions, endocrinopathy, and precocious puberty. We report the case of a 14-year-old boy, presenting with sclerotic type of polyostotic fibrous dysplasia. Radiological methods including plain X-ray film, MR and whole body bone scintigraphy suggested the diagnosis of MAS. MRI provided more directly perceived images and it was more sensitive in demonstrating the lesion: its shape, contents, especially the size of the affected region. Histopathological study and the identification of mutant gene finally confirmed the diagnostic result.

  17. Biofabrication of morphology improved cadmium sulfide nanoparticles using Shewanella oneidensis bacterial cells and ionic liquid: For toxicity against brain cancer cell lines.

    Science.gov (United States)

    Wang, Li; Chen, Siyuan; Ding, Yiming; Zhu, Qiang; Zhang, Nijia; Yu, Shuqing

    2018-01-01

    The present work determines the anticancer activity of bio-mediated synthesized cadmium sulfide nanoparticles using the ionic liquid and bacterial cells (Shewanella oneidensis). Bacterial cells have been exposed to be important resources that hold huge potential as ecofriendly, cost-effective, evading toxic of dangerous chemicals and the alternative of conventional physiochemical synthesis. The Shewanella oneidensis is an important kind of metal reducing bacterium, known as its special anaerobic respiratory and sulfate reducing capacity. The crystalline nature, phase purity and surface morphology of biosynthesized cadmium sulfide nanoparticles were analyzed by Fourier transform infrared spectroscopy, X-ray diffraction, Field emission scanning electron microscopy, Energy dispersive spectroscopy and Transmission electron microscopy. The use of imidazolium based ionic liquids as soft templating agent for controlling self-assembly and crystal growth direction of metal sulfide nanoparticles has also advanced as an important method. The microscopic techniques showed that the nanoparticles are designed on the nano form and have an excellent spherical morphology, due to the self-assembled mechanism of ionic liquid assistance. The antitumor efficiency of the cadmium sulfide nanoparticles was investigated against brain cancer cell lines using rat glioma cell lines. The effectively improved nano-crystalline and morphological structure of CdS nanoparticles in the presence of IL exhibit excellent cytotoxicity and dispersion ability on the cell shape is completely spread out showing a nice toxic environment against cancer cells. The cytotoxicity effect of cadmium sulfide nanoparticles was discussed with a diagrammatic representation. Copyright © 2017. Published by Elsevier B.V.

  18. MR imaging of colorectal carcinomas using an MR endoscopic coil

    International Nuclear Information System (INIS)

    Murano, Akihiko; Kido, Choichiro; Sasaki, Fumio; Nakamura, Tsuneya; Kobayashi, Semi; Katoh, Tomoyuki; Hirai, Takashi

    1994-01-01

    Diagnosis of the depth of wall invasion by rectal carcinoma using MR endoscopy was performed in ten resected specimens, including five rectal carcinomas, three colon carcinomas, two normal gastric wall. In addition, the gastric wall of a pig was examined. MR imaging was done with a 1.5-T Signa Advantage (GE Medical System) system, with the surface coil of the MR endoscope acting as the receiver coil. Five layers could be distinguished in the bowel wall: mucosa, submucosa and muscularis propria divided into circular muscle, longitudinal muscle and intervening connective tissue. Tumors had almost the same signal intensity as muscle. The MR images of colon carcinomas, rectal carcinomas, and extrinsically metastatic involvement of the sigmoid colon by rectal carcinoma all correlated well with the pathological findings. The normal structure of the gastric wall was similar to that of the colon. 3D-fast Spoiled Grass (SPGR) sequence has a fairly short scanning time. Thus, the possibility of precise clinical diagnosis by this method was suggested. (author)

  19. Evaluation of an automatic MR-based gold fiducial marker localisation method for MR-only prostate radiotherapy

    Science.gov (United States)

    Maspero, Matteo; van den Berg, Cornelis A. T.; Zijlstra, Frank; Sikkes, Gonda G.; de Boer, Hans C. J.; Meijer, Gert J.; Kerkmeijer, Linda G. W.; Viergever, Max A.; Lagendijk, Jan J. W.; Seevinck, Peter R.

    2017-10-01

    An MR-only radiotherapy planning (RTP) workflow would reduce the cost, radiation exposure and uncertainties introduced by CT-MRI registrations. In the case of prostate treatment, one of the remaining challenges currently holding back the implementation of an RTP workflow is the MR-based localisation of intraprostatic gold fiducial markers (FMs), which is crucial for accurate patient positioning. Currently, MR-based FM localisation is clinically performed manually. This is sub-optimal, as manual interaction increases the workload. Attempts to perform automatic FM detection often rely on being able to detect signal voids induced by the FMs in magnitude images. However, signal voids may not always be sufficiently specific, hampering accurate and robust automatic FM localisation. Here, we present an approach that aims at automatic MR-based FM localisation. This method is based on template matching using a library of simulated complex-valued templates, and exploiting the behaviour of the complex MR signal in the vicinity of the FM. Clinical evaluation was performed on seventeen prostate cancer patients undergoing external beam radiotherapy treatment. Automatic MR-based FM localisation was compared to manual MR-based and semi-automatic CT-based localisation (the current gold standard) in terms of detection rate and the spatial accuracy and precision of localisation. The proposed method correctly detected all three FMs in 15/17 patients. The spatial accuracy (mean) and precision (STD) were 0.9 mm and 0.5 mm respectively, which is below the voxel size of 1.1 × 1.1 × 1.2 mm3 and comparable to MR-based manual localisation. FM localisation failed (3/51 FMs) in the presence of bleeding or calcifications in the direct vicinity of the FM. The method was found to be spatially accurate and precise, which is essential for clinical use. To overcome any missed detection, we envision the use of the proposed method along with verification by an observer. This will result in a

  20. MR imaging of the shoulder

    International Nuclear Information System (INIS)

    Fritts, H.M.; Craig, E.; Kyle, R.; Strefling, M.; Miller, D.; Heithoff, K.; Schellhas, K.

    1988-01-01

    Magnetic resonance (MR) imaging (1.5-T unit) was performed in over 600 shoulders to evaluate shoulder pain. Ultrasound (US) and arthrography were performed in over 100 patients. Surgery was performed in over 75 patients. MR imaging offers information not well evaluated with other modalities, including bony impingement, tendinitis, bursitis, and osseous abnormalities, such as primary arthritis, avascular necrosis, occult fractures, and tumors. US and MR findings correlate well with surgical findings for medium to large rotator cuff tears. MR imaging with T2 weighting is superior for differentiating small tears from associated tendinitis. An algorithm for cost-effective shoulder imaging integrating US, MR imaging, arthrography, and computed tomographic arthrography are presented

  1. Disorders of migration and sulcation in infants and children: MR spectrum at 1.5 T

    International Nuclear Information System (INIS)

    Boyer, R.S.; Nixon, G.W.; Smoker, W.R.K.; Harnsberger, H.R.; Osborn, A.G.

    1987-01-01

    In 750 consecutive high-field-strength (1.5-T) pediatric brain MR imaging studies the authors encountered a fascinating spectrum of developmental anomalies of migration, gyration, and sulcation in 11 patients. Lesions were characterized by disorder anatomy but normal gray-matter signal. MR imaging was excellent in revealing pachygyria, polymicrogyria, agyria (lissencephaly), heterotopia, and schizencephaly, and in displaying associated development anomalies, such as agenesis of the corpus callosum, encephalocele, Chiari II malformation, septo-optic dysplasia, lobar holoprosencephaly, and unilateral megalencephaly. The improved demonstration of gray-matter abnormalities that is possible with high-field-strength MR imaging facilitates recognition of these lesions and associated anomalies

  2. Survival of Anaerobic Fe2+ Stress Requires the ClpXP Protease.

    Science.gov (United States)

    Bennett, Brittany D; Redford, Kaitlyn E; Gralnick, Jeffrey A

    2018-04-15

    Shewanella oneidensis strain MR-1 is a versatile bacterium capable of respiring extracellular, insoluble ferric oxide minerals under anaerobic conditions. The respiration of iron minerals results in the production of soluble ferrous ions, which at high concentrations are toxic to living organisms. It is not fully understood how Fe 2+ is toxic to cells anaerobically, nor is it fully understood how S. oneidensis is able to resist high levels of Fe 2+ Here we describe the results of a transposon mutant screen and subsequent deletion of the genes clpX and clpP in S. oneidensis , which demonstrate that the protease ClpXP is required for anaerobic Fe 2+ resistance. Many cellular processes are known to be regulated by ClpXP, including entry into stationary phase, envelope stress response, and turnover of stalled ribosomes. However, none of these processes appears to be responsible for mediating anaerobic Fe 2+ resistance in S. oneidensis Protein trapping studies were performed to identify ClpXP targets in S. oneidensis under Fe 2+ stress, implicating a wide variety of protein targets. Escherichia coli strains lacking clpX or clpP also display increased sensitivity to Fe 2+ anaerobically, indicating Fe 2+ resistance may be a conserved role for the ClpXP protease system. Hypotheses regarding the potential role(s) of ClpXP during periods of high Fe 2+ are discussed. We speculate that metal-containing proteins are misfolded under conditions of high Fe 2+ and that the ClpXP protease system is necessary for their turnover. IMPORTANCE Prior to the evolution of cyanobacteria and oxygenic photosynthesis, life arose and flourished in iron-rich oceans. Today, aqueous iron-rich environments are less common, constrained to low-pH conditions and anaerobic systems such as stratified lakes and seas, digestive tracts, subsurface environments, and sediments. The latter two ecosystems often favor dissimilatory metal reduction, a process that produces soluble Fe 2+ from iron oxide minerals

  3. Characterization of the first RF coil dedicated to 1.5 T MR guided radiotherapy

    Science.gov (United States)

    Hoogcarspel, Stan J.; Zijlema, Stefan E.; Tijssen, Rob H. N.; Kerkmeijer, Linda G. W.; Jürgenliemk-Schulz, Ina M.; Lagendijk, Jan J. W.; Raaymakers, Bas W.

    2018-01-01

    The purpose of this study is to investigate the attenuation characteristics of a novel radiofrequency (RF) coil, which is the first coil that is solely dedicated to MR guided radiotherapy with a 1.5 T MR-linac. Additionally, we investigated the impact of the treatment beam on the MRI performance of this RF coil. First, the attenuation characteristics of the RF coil were characterized. Second, we investigated the impact of the treatment beam on the MRI performance of the RF coil. We additionally demonstrated the ability of the anterior coil to attenuate returning electrons and thereby reducing the dose to the skin at the distal side of the treatment beam. Intensity modulated radiation therapy simulation of a clinically viable treatment plan for spinal bone metastasis shows a decrease of the dose to the planned tumor volume of 1.8% as a result of the MR coil around the patient. Ionization chamber and film measurements show that the anterior and posterior coil attenuate the beam homogeneously by 0.4% and 2.2%, respectively. The impact of the radiation resulted in a slight drop of the time-course signal-to-noise ratio and was dependent on imaging parameters. However, we could not observe any image artifacts resulting from this irradiation in any situation. In conclusion, the investigated MR-coil can be utilized for treatments with the 1.5 T-linac system. However, there is still room for improvement when considering both the dosimetric and imaging performance of the coil.

  4. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin; Sung, Ji Kyeong

    2015-01-01

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  5. {sup 1}H MR spectroscopy of mesial temporal lobe epilepsies treated with Gamma knife

    Energy Technology Data Exchange (ETDEWEB)

    Hajek, Milan; Dezortova, Monika [MR Unit, Department of Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague (Czech Republic); Center for Cell Therapy and Tissue Repair, V Uvalu 84, 150 00 Prague (Czech Republic); Liscak, Roman; Vymazal, Josef; Vladyka, Vilibald [Department of Stereotactic and Radiation Neurosurgery, Hospital Na Homolce, 151 19, Prague (Czech Republic)

    2003-05-01

    Proton MR spectroscopy was used to observe long-term post-irradiation metabolic changes in epileptogenic tissue and in the contralateral parts of the brain which are not available with conventional imaging methods. We studied these changes in the temporal lobe in six patients, following radiosurgery on the amygdala and hippocampus. {sup 1}H MR spectroscopy at 1.5 T with short and long echo times (TE=10 and 135 ms) were used together with standard MR imaging sequences (T1-, T2-weighted). The treatment was performed by Leksell Gamma Knife with a dose of 50 Gy to the center and a 50% isodose to the margin of the target, represented by the mean volume of approximately 7.5 ml. Magnetic resonance imaging and MR spectroscopy examinations were performed at least once per year for 3 years. The most significant changes in spectra were observed approximately 1 year after the irradiation when edema in irradiated area was observed and strong signal of lipids was identified. Later, edema and lipid signals disappeared and follow-up was characterized by a decrease of NAA, Cr, and Cho concentrations in the ipsilateral region of the brain to the irradiation (LCModel calculation from voxel of interest 3.8-4.5 ml positioned into the centrum of target volume). The concentration of NAA, Cr, and Cho after radiosurgery was significantly different from control values (p<0.05) and also from concentrations in the contralateral part of the brain (p<0.05). In the contralateral part, the concentration of NAA was significantly increased (p<0.05) (NAA: before treatment 8.81, after treatment 11.33 mM). No radiotoxic changes were observed in the contralateral part of the brain or behind the area of target volume. The MR spectroscopy findings precluded MRI observation and MRS results completed data about the development of radiotoxic changes in the target volume. (orig.)

  6. Feasibility of MR urography in patients with urinary diversion

    International Nuclear Information System (INIS)

    Battal, Bilal; Kocaoglu, Murat; Ilica, Turan; Akgun, Veysel; Aydur, Emin; Dayanc, Murat

    2011-01-01

    The aims of this study were to determine the diagnostic value of MR urography and to compare the T2- and T1-weighted MR urography techniques in patients with urinary diversion. We retrospectively reviewed 19 MR urograms in 14 patients (13 male and one female, 8–77 years old, mean age: 54.2) with urinary diversion. Magnetic resonance urography examinations were performed with 1.5-T MR scanners. In addition to T2- and T1-weighted MR urography techniques, conventional T1- and T2-weighted axial and coronal sequences were also obtained. Collecting systems were evaluated in five segments (right proximal and distal collecting system, left proximal and distal collecting system and conduit or reservoir). Imaging features of the urinary collecting systems were evaluated with T2- and T1-weighted MR urography images. The clinical, laboratory data and follow-up imaging findings were regarded as standard. A cross table was formed to determine sensitivity, specificity and accuracy of MR urography techniques. T2-weighted MR urography, T1-weighted MR urography and combination of these two techniques could demonstrate 89.01, 87.65 and 93.83% of all collecting system segments, respectively. For the detection of the pathologic urinary segments, sensitivity, specificity and accuracy were 100, 95.29 and 95.6% in T2-weighted MR urography and 100, 93.42 and 93.82% in T1-weighted MR urography, respectively. Sensitivity, specificity and accuracy were 100% in combined T2- and T1-weighted MR urography technique. Magnetic resonance urography is an effective imaging method for the evaluation of the urinary system in patients with urinary diversion. T2-weighted MR urography alone has high sensitivity, specificity and accuracy, does not require intravenous contrast medium and can be obtained in 3–5 min. However, T1-weighted MR urography may provide additional information in some cases.

  7. Chondromalacia patellae: diagnosis with MR imaging.

    Science.gov (United States)

    McCauley, T R; Kier, R; Lynch, K J; Jokl, P

    1992-01-01

    Most previous studies of MR imaging for detection of chondromalacia have used T1-weighted images. We correlated findings on axial MR images of the knee with arthroscopic findings to determine MR findings of chondromalacia patellae on T2-weighted and proton density-weighted images. The study population included 52 patients who had MR examination of the knee with a 1.5-T unit and subsequent arthroscopy, which documented chondromalacia patellae in 29 patients and normal cartilage in 23. The patellar cartilage was assessed retrospectively for MR signal and contour characteristics. MR diagnosis based on the criteria of focal signal or focal contour abnormality on either the T2-weighted or proton density-weighted images yielded the highest correlation with the arthroscopic diagnosis of chondromalacia. When these criteria were used, patients with chondromalacia were detected with 86% sensitivity, 74% specificity, and 81% accuracy. MR diagnosis based on T2-weighted images alone was more sensitive and accurate than was diagnosis based on proton density-weighted images alone. In conclusion, most patients with chondromalacia patellae have focal signal or focal contour defects in the patellar cartilage on T2-weighted MR images. These findings are absent in most patients with arthroscopically normal cartilage.

  8. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Won C.; Chang, Eric Y.; Chung, Christine B. [VA San Diego Healthcare System, Radiology Service, San Diego, CA (United States); University of California-San Diego, Department of Radiology, San Diego, CA (United States); Ruangchaijatuporn, Thumanoon [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Rachathewi, Bangkok (Thailand); Biswas, Reni; Du, Jiang; Statum, Sheronda [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2016-04-15

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. (orig.)

  9. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties

    International Nuclear Information System (INIS)

    Bae, Won C.; Chang, Eric Y.; Chung, Christine B.; Ruangchaijatuporn, Thumanoon; Biswas, Reni; Du, Jiang; Statum, Sheronda

    2016-01-01

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. (orig.)

  10. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties.

    Science.gov (United States)

    Bae, Won C; Ruangchaijatuporn, Thumanoon; Chang, Eric Y; Biswas, Reni; Du, Jiang; Statum, Sheronda; Chung, Christine B

    2016-04-01

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques.

  11. Bias atlases for segmentation-based PET attenuation correction using PET-CT and MR.

    Science.gov (United States)

    Ouyang, Jinsong; Chun, Se Young; Petibon, Yoann; Bonab, Ali A; Alpert, Nathaniel; Fakhri, Georges El

    2013-10-01

    This study was to obtain voxel-wise PET accuracy and precision using tissue-segmentation for attenuation correction. We applied multiple thresholds to the CTs of 23 patients to classify tissues. For six of the 23 patients, MR images were also acquired. The MR fat/in-phase ratio images were used for fat segmentation. Segmented tissue classes were used to create attenuation maps, which were used for attenuation correction in PET reconstruction. PET bias images were then computed using the PET reconstructed with the original CT as the reference. We registered the CTs for all the patients and transformed the corresponding bias images accordingly. We then obtained the mean and standard deviation bias atlas using all the registered bias images. Our CT-based study shows that four-class segmentation (air, lungs, fat, other tissues), which is available on most PET-MR scanners, yields 15.1%, 4.1%, 6.6%, and 12.9% RMSE bias in lungs, fat, non-fat soft-tissues, and bones, respectively. An accurate fat identification is achievable using fat/in-phase MR images. Furthermore, we have found that three-class segmentation (air, lungs, other tissues) yields less than 5% standard deviation of bias within the heart, liver, and kidneys. This implies that three-class segmentation can be sufficient to achieve small variation of bias for imaging these three organs. Finally, we have found that inter- and intra-patient lung density variations contribute almost equally to the overall standard deviation of bias within the lungs.

  12. The use of MR B+1 imaging for validation of FDTD electromagnetic simulations of human anatomies

    International Nuclear Information System (INIS)

    Berg, Cornelis A T van den; Bartels, Lambertus W; Bergen, Bob van den; Kroeze, Hugo; Leeuw, Astrid A C de; Kamer, Jeroen B van de; Lagendijk, Jan J W

    2006-01-01

    In this study, MR B + 1 imaging is employed to experimentally verify the validity of FDTD simulations of electromagnetic field patterns in human anatomies. Measurements and FDTD simulations of the B + 1 field induced by a 3 T MR body coil in a human corpse were performed. It was found that MR B + 1 imaging is a sensitive method to measure the radiofrequency (RF) magnetic field inside a human anatomy with a precision of approximately 3.5%. A good correlation was found between the B + 1 measurements and FDTD simulations. The measured B + 1 pattern for a human pelvis consisted of a global, diagonal modulation pattern plus local B + 1 heterogeneties. It is believed that these local B + 1 field variations are the result of peaks in the induced electric currents, which could not be resolved by the FDTD simulations on a 5 mm 3 simulation grid. The findings from this study demonstrate that B + 1 imaging is a valuable experimental technique to gain more knowledge about the dielectric interaction of RF fields with the human anatomy

  13. Conspicuity of diffuse axonal injury lesions on diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Toshibumi [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States)]. E-mail: kino@grape.med.tottori-u.ac.jp; Moritani, Toshio [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Hiwatashi, Akio [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Wang, Henry Z. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Shrier, David A. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Numaguchi, Yuji [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Westesson, Per-Lennart A. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States)

    2005-10-01

    Objective: (1) To detect diffuse axonal injury (DAI) lesions by diffusion-weighted imaging (DWI), as compared with fluid-attenuated inversion recovery (FLAIR) imaging and (2) to evaluate hemorrhagic DAI lesions by b{sub 0} images obtained from DWI, as compared with gradient-echo (GRE) imaging. Methods: We reviewed MR images of 36 patients with a diagnosis of DAI. MR imaging was performed 20 h to 14 days (mean, 3.7 days) after traumatic brain injury. We evaluated: (1) conspicuity of lesions on DWI and FLAIR and (2) conspicuity of hemorrhage in DAI lesions on b{sub 0} images and GRE imaging. Results: DWI clearly depicted high-signal DAI lesions. The sensitivity of DWI to lesional conspicuity in DAI lesions was almost equal to that of FLAIR. The sensitivity of b{sub 0} images to identification of hemorrhagic DAI lesions was inferior to that of GRE. Conclusion: DWI is as useful as FLAIR in detecting DAI lesions. GRE imaging is still the superior tool for the evaluation of hemorrhagic DAI.

  14. Microbial Reducibility of Fe(III Phases Associated with the Genesis of Iron Ore Caves in the Iron Quadrangle, Minas Gerais, Brazil

    Directory of Open Access Journals (Sweden)

    Ceth W. Parker

    2013-11-01

    Full Text Available The iron mining regions of Brazil contain thousands of “iron ore caves” (IOCs that form within Fe(III-rich deposits. The mechanisms by which these IOCs form remain unclear, but the reductive dissolution of Fe(III (hydroxides by Fe(III reducing bacteria (FeRB could provide a microbiological mechanism for their formation. We evaluated the susceptibility of Fe(III deposits associated with these caves to reduction by the FeRB Shewanella oneidensis MR-1 to test this hypothesis. Canga, an Fe(III-rich duricrust, contained poorly crystalline Fe(III phases that were more susceptible to reduction than the Fe(III (predominantly hematite associated with banded iron formation (BIF, iron ore, and mine spoil. In all cases, the addition of a humic acid analogue enhanced Fe(III reduction, presumably by shuttling electrons from S. oneidensis to Fe(III phases. The particle size and quartz-Si content of the solids appeared to exert control on the rate and extent of Fe(III reduction by S. oneidensis, with more bioreduction of Fe(III associated with solid phases containing more quartz. Our results provide evidence that IOCs may be formed by the activities of Fe(III reducing bacteria (FeRB, and the rate of this formation is dependent on the physicochemical and mineralogical characteristics of the Fe(III phases of the surrounding rock.

  15. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    International Nuclear Information System (INIS)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo

    1994-01-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author)

  16. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1994-09-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author).

  17. 77 FR 65545 - Mr. Jesse S. Capel and Mr. Hilton J. Cochran; EWP LLC; Notice of Transfer of Exemption

    Science.gov (United States)

    2012-10-29

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 4815-009] Mr. Jesse S. Capel and Mr. Hilton J. Cochran; EWP LLC; Notice of Transfer of Exemption 1. By application filed on July 30, 2012 and supplemented on August 14, 2012, Mr. Jesse S. Capel and Mr. Hilton J. Cochran and EWP...

  18. MR of experimental cerebral ischemia

    International Nuclear Information System (INIS)

    DeLaPaz, R.; Steinberg, G.; Rocklage, S.; Glover, G.H.

    1990-01-01

    This paper reports on MR imaging of cerebral ischemia and treatment with N-methyl-D-aspartate (NMDA) antagonists in an animal model. Forty-four New Zealand white rabbits underwent 1-hour transorbital ICA-MCA-ACA occlusion and pretreatment or immediate posttreatment with systemic dextromethorphan (DM, n = 14), dextrorphan (DX, n = 14), or normal saline (NS, n = 16). Serial MR studies (1.5 T) were performed 1--6 hours after occlusion with T1- and T2-weighted spinecho, IVIM (b = 1,352), gradient recalled acquisition in a steady-state, and chemical shift sequences (for magnetic susceptibility, T2* and T2') and DyDTPA-BMA intravenous contrast material (Salutar). Spatial correlation between MR findings, histologic findings (ischemic neuronal damage), and regional cerebral blood flow (microspheres) was done

  19. Investigating the generalisation of an atlas-based synthetic-CT algorithm to another centre and MR scanner for prostate MR-only radiotherapy

    Science.gov (United States)

    Wyatt, Jonathan J.; Dowling, Jason A.; Kelly, Charles G.; McKenna, Jill; Johnstone, Emily; Speight, Richard; Henry, Ann; Greer, Peter B.; McCallum, Hazel M.

    2017-12-01

    There is increasing interest in MR-only radiotherapy planning since it provides superb soft-tissue contrast without the registration uncertainties inherent in a CT-MR registration. However, MR images cannot readily provide the electron density information necessary for radiotherapy dose calculation. An algorithm which generates synthetic CTs for dose calculations from MR images of the prostate using an atlas of 3 T MR images has been previously reported by two of the authors. This paper aimed to evaluate this algorithm using MR data acquired at a different field strength and a different centre to the algorithm atlas. Twenty-one prostate patients received planning 1.5 T MR and CT scans with routine immobilisation devices on a flat-top couch set-up using external lasers. The MR receive coils were supported by a coil bridge. Synthetic CTs were generated from the planning MR images with (sCT1V ) and without (sCT) a one voxel body contour expansion included in the algorithm. This was to test whether this expansion was required for 1.5 T images. Both synthetic CTs were rigidly registered to the planning CT (pCT). A 6 MV volumetric modulated arc therapy plan was created on the pCT and recalculated on the sCT and sCT1V . The synthetic CTs’ dose distributions were compared to the dose distribution calculated on the pCT. The percentage dose difference at isocentre without the body contour expansion (sCT-pCT) was Δ D_sCT=(0.9 +/- 0.8) % and with (sCT1V -pCT) was Δ D_sCT1V=(-0.7 +/- 0.7) % (mean  ±  one standard deviation). The sCT1V result was within one standard deviation of zero and agreed with the result reported previously using 3 T MR data. The sCT dose difference only agreed within two standard deviations. The mean  ±  one standard deviation gamma pass rate was Γ_sCT = 96.1 +/- 2.9 % for the sCT and Γ_sCT1V = 98.8 +/- 0.5 % for the sCT1V (with 2% global dose difference and 2~mm distance to agreement gamma criteria). The one voxel body contour

  20. Tolerance of magnetic resonance imaging in children and adolescents performed in a 1.5 Tesla MR scanner with an open design

    International Nuclear Information System (INIS)

    Adamietz, B.; Cavallaro, A.; Radkow, T.; Alibek, S.; Bautz, W.A.; Holter, W.; Staatz, G.

    2007-01-01

    Purpose: To investigate the tolerance of MR examinations in children and adolescents performed in a 1.5 Tesla MR scanner with an expanded bore diameter. Method and Materials: 163 patients, ages 4 to 25, underwent MR examinations in a 1.5 Tesla MR scanner with an open design (MAGNETOM Espree, Siemens, Erlangen, Germany), characterized by a compact length of 125 cm and an expanded 70 cm bore diameter. MR imaging of the brain was carried out in most cases (78.5 %), followed by examinations of the spinal canal (9.8 %), the extremities (9.2 %) and the neck (2.5 %). The patients were divided into four age groups and the success rate, motion artifacts and diagnostic quality of the MR examinations were assessed using a 3-grade scale. Results: In 119 of 163 patients (73.0 %), MR examination was possible without any motion artifacts. With respect to the different age groups, 41.7 % of the 4 - 7-year-old children, 67.6 % of the 8 - 10-year-old children, 84.1 % of the 11 - 16-year-old children and 95.8 % of the patients older than 17 showed tolerance grade I without motion artifacts and excellent diagnostic image quality. In 39 of 163 children (23.9 %), the MR images showed moderate motion artifacts but had sufficient diagnostic quality. With regard to the different age groups, 52.8 % of the 4 - 7-year-old children, 26.5 % of the 8 - 10-year-old children, 15.9 % of the 11 - 16-year-old children and none of the patients older than 17 showed tolerance grade II with moderate motion artifacts and sufficient diagnostic image quality. In only 4 of 124 children 10 years old, the MR examination was not feasible and had to be repeated under sedation. Conclusion: Pediatric MR imaging using a 1.5 Tesla MR scanner with an open design can be conducted in children and adolescents with excellent acceptance. The failure rate of 3.0 % of cases for pediatric MR imaging is comparable to that of a conventional low-field open MR scanner. (orig.)

  1. MR-guided direct arthrography of the glenohumeral joint

    International Nuclear Information System (INIS)

    Soh, E.; Bearcroft, P.W.P.; Graves, M.J.; Black, R.; Lomas, D.J.

    2008-01-01

    Aim: To evaluate the feasibility of magnetic resonance (MR)-guided direct arthrography of the glenohumeral joint with a 1.5 T MR system, performing the entire procedure in a single MR examination. Materials and methods: MR-guided direct arthrography was performed on 11 patients. MR imaging guidance and interactive MR fluoroscopy, with in-room control and display system, were used for needle placement and contrast medium injection. The outcome measures were success or failure of joint puncture, the time taken for introduction of contrast medium, and the diagnostic quality of the subsequent MR arthrography images. Results: Contrast medium was successfully instilled into the joint and diagnostic quality MR arthrography images were obtained in all cases. The median time from initial placement of the skin marker to introduction of the contrast medium was 17 min (range 11-29 min). There were no immediate post-procedure complications. Conclusion: Accurate needle placement is feasible in a single MR examination on a commercial 1.5 T closed-bore MR system, using an in-room control and display system together with interactive fluoroscopic imaging, and this was used to provide direct MR arthrography in this study

  2. Extracellular electron transfer mechanism in Shewanella loihica PV-4 biofilms formed at indium tin oxide and graphite electrodes

    Digital Repository Service at National Institute of Oceanography (India)

    Jain, A.; Connolly, J.O.; Woolley, R.; Krishnamurthy, S.; Marsili, E.

    /electrode interface [21]. After 24 h from inoculation, the sigmoidal wave disappeared and cyclic voltammetry detected reversible peaks with Em value -0.3 V, most likely due to the production of redox mediator(s) in the cell suspension under anaerobic conditions... reported earlier from the whole cell voltammetry of S. loihica PV- 4 (-0.054 V vs. Ag/AgCl) [18] as well as of S. oneidensis MR-1 (-0.07 V vs. Ag/AgCl) [29]. The Em value obtained for RC (I) was shifted to a more positive potential from those reported...

  3. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Joerg [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Ludwig Boltzmann Institute for Osteology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Bernt, Reinhard [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria)]. E-mail: reinhard.bernt@wgkk.sozvers.at; Seeger, Thomas [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Weissenbaeck, Alexander [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Tuechler, Heinrich [Ludwig Boltzmann Institute for Hematology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Resnick, Donald [Department of Radiology, VA Medical Center, UCSD, 3350 La Jolla Village Dr, San Diego, CA 92161 (United States)

    2006-06-15

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome.

  4. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    International Nuclear Information System (INIS)

    Haller, Joerg; Bernt, Reinhard; Seeger, Thomas; Weissenbaeck, Alexander; Tuechler, Heinrich; Resnick, Donald

    2006-01-01

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome

  5. MR-fluid yield surface determination in disc-type MR rotary brakes

    International Nuclear Information System (INIS)

    Farjoud, Alireza; Vahdati, Nader; Fah, Yap Fook

    2008-01-01

    Magneto-rheological (MR) fluids are currently attracting a great deal of attention because of their unique rheological behavior. Many devices have been designed using MR fluids, and of potential interest here are disc-type MR rotary brakes. The plug flow region in MR devices is defined as the region where the fluid is not flowing. The plug flow region plays an important role in design and analysis of MR devices. In MR dampers, the damping coefficient is a function of the plug thickness. In MR valves, the plug thickness is used to control the flow rate through, and the pressure drop across, the MR valve. A MR clutch is performing at the highest efficiency when the entire MR gap is the plug region. For an MR rotary brake, the highest restraining torque is obtained when the entire gap is the plug region as far as there are no wall slip effects. In this paper, using the Bercovier and Engelman constitutive model, the MR fluid flow in disc-type MR brakes is modeled to determine the plug flow region. The resulting system of equations is solved numerically. It is shown that the existence of a plug flow region in the brake will affect the control torque ratio. Better estimation of the plug flow region results in better estimation of the viscous torque

  6. MR staging of malignant musculoskeletal tumors: An experimental study on MR and pathologic correlation of rabbit VX-2 carcinoma

    International Nuclear Information System (INIS)

    Kang, Heung Sik; Chung, Sung Hoon; KIm, Cheol Woo; Kim, Seong Moon; Im, Jung Gi; Han, Man Chung

    1993-01-01

    To evaluate the reliability of MR imaging in tissue characterization and depiction of tumor boundaries, we performed MR pathologic correlation using parosteally implanted VX-2 carcinoma in 17 rabbit thighs. T1-weighted, T2-weighted and Gd-DTPA enhanced T1-weighted axial images were obtained 10-30 days after tumor implantation. After the animals were killed, frozen and sectioned along the MR imaging planes, and histopathologic examination were done. For accurate MR pathologic correlation, rabbit were fixed on the cardboard plate to minimize position change during the procedure. Tumor boundaries depicted on MR images were larger than those depicted on the specimen. Small tumors were surrounded by capsule-like loose connective tissue. Loose connective tissue became compact with tumor growth. This connective tissue showed high signal intensity on both T2-weighted and Gd-DTPA enhanced T1-weighted images. Muscle atrophy with fatty tissue accumulation around the tumor also contributed to the high signal intensity on MR images. Peritumoral edema and inflammatory reaction were not remarkable. Six of 8 cases with bone marrow fibrosis were detected on MR images. We concluded that peritumoral loose connective tissue and muscle atrophy exaggerated the size of experimentally induced malignant musculoskeletal tumors on MR images

  7. Value of 3.0 T MR imaging in refractory partial epilepsy and negative 1.5 T MRI.

    Science.gov (United States)

    Nguyen, Dang Khoa; Rochette, Emilie; Leroux, Jean-Maxime; Beaudoin, Gilles; Cossette, Patrick; Lassonde, Maryse; Guilbert, François

    2010-10-01

    High-field 3.0 T MR scanners provide an improved signal-to-noise ratio which can be translated in higher image resolution, possibly allowing critical detection of subtle epileptogenic lesions missed on standard-field 1.0-1.5 T MRIs. In this study, the authors explore the potential value of re-imaging at 3.0 T patients with refractory partial epilepsy and negative 1.5 T MRI. We retrospectively identified all patients with refractory partial epilepsy candidate for surgery who had undergone a 3.0 T MR study after a negative 1.5 T MR study. High-field 3.0 T MRIs were reviewed qualitatively by neuroradiologists experienced in interpreting epilepsy studies with access to clinical information. Relevance and impact on clinical management were assessed by an epileptologist. Between November 2006 and August 2009, 36 patients with refractory partial epilepsy candidate for surgery underwent 3.0 T MR study after a 1.5 T MR study failed to disclose a relevant epileptogenic lesion. A potential lesion was found only in two patients (5.6%, 95% CI: 1.5-18.1%). Both were found to have hippocampal atrophy congruent with other presurgical localization techniques which resulted in omission of an invasive EEG study and direct passage to surgery. The frequency of detection of a new lesion by re-imaging at 3.0 T patients with refractory partial epilepsy candidate for surgery was found to be low, but seems to offer the potential of a significant clinical impact for selected patients. This finding needs to be validated in a prospective controlled study. Copyright © 2010 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  8. A comparative study of MR imaging scores and MR perfusion imaging in pre-operative grading of intracranial gliomas

    International Nuclear Information System (INIS)

    Wu Honglin; Chen Junkun; Zhang Zongjun; Lu Guangming; Chen Ziqian; Wang Wei; Ji Xueman; Tang Xiaojun; Li Lin

    2005-01-01

    Objective: To compare the accuracy of MR imaging scores with MR perfusion imaging in pre-operative grading of intracranial gliomas. Methods: Thirty patients with intracranial gliomas (8 low-grade and 22 high-grade, according to WHO criteria) were examined with MR perfusion imaging pre-operatively. The lesions were evaluated by using an MR imaging score based on nine criteria. rCBV of the lesions were calculated by comparing the CBV of the lesion and that of contralateral normal white matter. The scores and ratios in high-grade and low-grade tumours were compared. Results: The MR imaging score of low grade (grades I and II) gliomas (0.67±0.29) were significantly lower than that of grades III (1.32 ± 0.47) (t=-3.48, P=0.003) and IV (1.56 ± 0.20) (t=-7.36, P=0.000) gliomas. There was no statistical difference when MR imaging scores of grades III and IV gliomas (t=-1.39, P=0.182) were compared. The maximum rCBV ratio of low grade (grades I and II) gliomas (2.38 ± 0.66 ) were significantly lower than that of grades III (5.81 ± 3.20) (t=-3.57, P=0.003) and IV (6.99 ± 2.47) (t=-5.09, P=0.001). There was no statistical difference when rCBV ratios of grades III and IV (t =-0.93, P=0.365) gliomas were compared. The accuracy of MR imaging scores in the noninvasive grading of untreated gliomas was all most the same as that of MR perfusion imaging (90.00% vs 89.29%). Conclusion: The MR imaging scores and MR perfusion imaging are two very useful tools in the evaluation of the histopathologic grade of cerebral gliomas. The overall accuracy in the noninvasive grading of gliomas may be imp roved if MR imaging scores and MR perfusion imaging are combined. (authors)

  9. Chemical shift-selective snapshot FLASH MR imaging in combination with inversion-recovery T1 contrast at different field strengths

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Henrich, D.; Duhmke, E.

    1991-01-01

    With fast MR imaging, chemical shift contract becomes available to the clinician in seconds. The purpose of this paper is to evaluate the combination of chemical shift selective (CHESS) MR imaging using the snapshot FLASH MR method with the inversion-recovery technique and to obtain information concerning the signal-to-noise and chemical shift with the presaturation method at different field strengths. Investigations with volunteers and experimental animals were done at 2 and 3 T (whole body) and in a 4.7-T animal image. For the inversion-recovery experiments, saturation was done before every snapshot FLASH image. With increasing field strength due to signal-to-noise and chemical shift advantages, the method performs better. Increasing T1 values are also important at high field strengths. The combined technique is useful only for T1 water images with fat saturation. It also allows fast quantification of T1 in water-containing organs and pathologic processes. At high field strengths, fast CHESS and T1 imaging promise fast quantitative information. This is a possible argument for clinical high-field-strength MR imagining along with MR spectroscopy

  10. CT and MR imaging findings of sphenoidal masses

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Shoki; Higano, Shuichi (Tohoku Univ., Sendai (Japan). School of Medicine); Ishii, Kiyoshi (and others)

    1994-07-01

    CT and MR imaging findings of 57 sphenoidal masses were retrospectively reviewed to assess the possibility of differential diagnosis between them. Various kinds of masses such as pituitary adenoma, epipharyngeal cancer, mucocele, chordoma, chondroma, chondrosarcoma, distant metastasis, multiple myeloma, fibrous dysplasia, craniopharyngioma, hemangiopericytoma, giant cell tumor, primary sphenoidal cancer, malignant melanoma, leukemia, histiocytosis X, and giant cell tumor were included in this series. CT scanning was performed in all cases using a spin-echo pulse sequence. The relative density of the masses, bony changes and calcification were evaluated on CT, and on MR images, signal intensity of the masses relative to the normal gray matter, contrast enhancement and extension/contour were evaluated. Although no single feature appeared to be specific to the masses, detection of calcification on CT, identification of the normal pituitary gland as deformed or displaced on T1-weighted images, signal intensity on T2-weighted images, and extension of the masses seemed to be useful and should be examined in terms of their ability to assist in differential diagnosis. Finally, accommodative classification of sphenoidal masses primarily based on presumed origin or mode of extension was attempted. (author).

  11. MR of acute subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Spickler, E.; Lufkin, R.; Frazee, J.; Lylyk, P.; Vinuela, F.; Bentson, J.; Dion, J.

    1987-01-01

    Subarachnoid hemorrhage was produced in four Macaca nemestrina monkeys using the technique of Frazee. CT and MR imaging was performed immediately after the procedure and at frequent intervals up to 2 weeks after hemorrhage. The imaging studies were compared with clinical evaluations and pathologic specimens of all animals. Additional human clinical CT/MR studies of subarachnoid hemorrhage were also studied. Acute hemorrhage was recognized on MR images as an increase in signal in the region of clot compared with surrounding cerebrospinal fluid. This most likely reflects T1 shortening due to proton binding rather than a pure paramagnetic effect. While CT is sensitive to the hemoglobin protein in acute hemorrhage, the superior resolution of MR of the basal cisterns results in equal or better definition of acute subarachnoid hemorrhage on MR studies in many cases

  12. MR imaging of the shoulder

    International Nuclear Information System (INIS)

    Heuck, A.; Appel, M.; Kaiser, E.; Luttke, G.; Lukas, P.

    1990-01-01

    This paper evaluates the occurrence, frequency, and significance of increased signal intensity (SI) in the rotator cuff (RC) of normal volunteers suggestive of pathologic findings such as partial tears and tendinitis. Shoulders of 30 volunteers without evidence of prior shoulder disease or trauma were studied. MR imaging at 1.5 T included T1-weighted, proton-density, and T2-weighted spin-echo (SE) and T2*-weighted gradient-echo sequences in axial, oblique coronal, and sagittal planes. Shoulders of 30 cadavers were dissected and studied for correlation with MR findings, five of them after MR examination

  13. Synthesis and characterization of magneto-rheological (MR fluids for MR brake application

    Directory of Open Access Journals (Sweden)

    Bhau K. Kumbhar

    2015-09-01

    Full Text Available Magneto rheological (MR fluid technology has been proven for many industrial applications like shock absorbers, actuators, etc. MR fluid is a smart material whose rheological characteristics change rapidly and can be controlled easily in presence of an applied magnetic field. MR brake is a device to transmit torque by the shear stress of MR fluid. However, MR fluids exhibit yield stress of 50–90 kPa. In this research, an effort has been made to synthesize MR fluid sample/s which will typically meet the requirements of MR brake applications. In this study, various electrolytic and carbonyl iron powder based MR fluids have been synthesized by mixing grease as a stabilizer, oleic acid as an antifriction additive and gaur gum powder as a surface coating to reduce agglomeration of the MR fluid. MR fluid samples based on sunflower oil, which is bio-degradable, environmentally friendly and abundantly available have also been synthesized. These MR fluid samples are characterized for determination of magnetic, morphological and rheological properties. This study helps identify most suitable localized MR fluid meant for MR brake application.

  14. Feasibility of MR-guided angioplasty of femoral artery stenoses using real-time imaging and intraarterial contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Paetzel, C.; Zorger, N.; Bachthaler, M.; Voelk, M.; Seitz, J.; Herold, T.; Feuerbach, S.; Lenhart, M.; Nitz, W.R.

    2004-01-01

    Purpose: To show the feasibility of magnetic resonance (MR) for guided interventional therapy of femoral and popliteal artery stenoses with commercially available materials supported by MR real-time imaging and intraarterial MR angiography. Materials and Methods: Three patients (1 female, 2 male), suffering from symptomatic arterial occlusive disease with stenoses of the femoral (n=2) or popliteal (n=1) arteries were included. Intraarterial digital subtraction angiography was performed in each patient pre- and post-interventionally as standard of reference to quantify stenoses. The degree of the stenoses reached from 71-88%. The MR images were acquired on a 1.5 T MR scanner (Magnetom Sonata; Siemens, Erlangen, Germany). For MR-angiography, a Flash 3D sequence was utilized following injection of 5 mL diluted gadodiamide (Omniscan; Amersham Buchler, Braunschweig, Germany) via the arterial access. Two maximum intensity projections (MIP) were used as road maps and localizer for the interactive positioning of a continuously running 2D-FLASH sequence with a temporal solution of 2 images per second. During the intervention, an MR compatible monitor provided the image display inside the scanner room. Safety guidelines were followed during imaging in the presence of a conductive guidewire. The lesion was crossed by a commercially available balloon catheter (Wanda, Boston Scientific; Ratingen, Germany), which was mounted on a 0.035'' guidewire (Terumo; Leuven, Belgium). The visibility was provided by radiopaque markers embedded in the balloon and was improved by injection of 1 mL gadodiamide into the balloon. After dilation, the result was checked by intraarterial MR angiography and catheter angiography. Results: The stenoses could be correctly localized by intraarterial MR angiography. There was complete correlation between intraarterial MR angiography and digital subtraction angiography. The combination of guidewire and balloon was visible and the balloon was placed

  15. The effect of patient positioning on MR imaging of the internal auditory canal

    International Nuclear Information System (INIS)

    Daniels, D.L.; Czervionke, L.F.; Yu, S.; Ho, P.S.P.; Pech, P.; Pojunas, K.W.; Williams, A.L.; Haughton, V.M.

    1988-01-01

    Identification of individual cranial nerves and complete exclusion of tumor in the internal auditory canal may be difficult with MR, especially in imperfectly positioned patients. MR studies of the temporal bones in patients and in normal volunteers positioned non-rotated or canted were correlated with corresponding cryomicrotomic sections. Especially in axial images, oblique sectioning of cranial nerves VII and VIII may cause difficulty in identifying individual nerves. A combination of axial and coronal short TR and TE images can be used to confidently exclude intracanalicular tumor in most cases. (orig.)

  16. Preoperative evaluation of neurovascular relationship by using contrast-enhanced and unenhanced 3D time-of-flight MR angiography in patients with trigeminal neuralgia

    International Nuclear Information System (INIS)

    Qin, Zhou; Zhiling, Liu; Chuanfu, Li; Qingshi Zeng; Chuncheng, Qu; Shilei, Ni

    2011-01-01

    Background Microvascular decompression is an etiological strategy for the therapy of trigeminal neuralgia (TN). Preoperative identification of neurovascular compression, therefore, could have an impact on the determination of appropriate treatment for TN. Purpose To evaluate the value of contrast-enhanced and unenhanced three-dimensional (3D) time-of-flight (TOF) MR angiography in the visualization of neurovascular relationship in patients with TN. Material and Methods Thirty-seven patients with unilateral TN underwent unenhanced and contrast-enhanced 3D TOF MR angiography with a 3.0-T MR system. Images were reviewed by a radiologist blinded to clinical details. Vascular contact with the trigeminal nerve was identified, and the nature of the involved vessels (artery or vein) was determined. All patients underwent microvascular decompression. Results In 37 patients with TN, contrast-enhanced 3D TOF MR angiography identified surgically verified neurovascular contact in 35 of 36 symptomatic nerves, and there was no false-positive. Based on surgical findings, the sensitivity of MR imaging was 97.2% and specificity 100%. The nature of the offending vessel was correctly identified in 94.4% of the patients by using the combination of contrast-enhanced and unenhanced MR angiography. Conclusion Contrast-enhanced 3D TOF MR angiography is useful in the detection of vascular contact with the trigeminal nerve in patients with TN, and this MR imaging in combination with unenhanced MR angiography could help in the identification of the nature of the responsible vessels

  17. Fast FLAIR MR images of intracranial hemorrhage

    International Nuclear Information System (INIS)

    Chun, Eun Ju; Choi, Hye Young; Cho, Young A; Kim, Wha Young

    1998-01-01

    The purpose of this study is to evaluate the signal characteristics of intracranial hemorrhage, as seen on fluid attenuated inversion recovery (FLAIR) MR imaging according to various stages, and to compare FLAIR imaging with spin-echo T1- and T2-weighted MR imaging. We retrospectively evaluated fast FLAIR images along with spin-echo T1- and T2 weighted MR images of 32 lesions in 25 patients (12 males and 14 females, aged 3 - 84 yrs) with intracranial hemorrhagic lesions. For imaging, 1.5 T unit was used, and the nature of the lesions was found to be as follows : intracranial hemorrhage (n=15); tumor (n=9); infarction (n=4); arteriovenous malformation (n=3); and arachnoid cyst with hemorrhage (n=1). On the basis of spin-echo MR imaging, lesions were classified as acute, early subacute, late subacute, early chronic, or late chronic stage. The signal characteristics of intracranial hemorrhage were analysed in accordance with each staging, as seen on MR FLAIR imaging, and compared to the staging seen on spin-echo T1- and T-2 weighted MR imaging. The signal intensity of intracranial hemorrhage, as seen on FLAIR imaging, was not characteristic; it was similar to that of T2WI during the acute and subacute stages, and similiar to that of T1WI during the chronic stage. When used together with spin-echo T1- and T2-weighted MR imaging, however, FLAIR imaging may be useful for the classification of chronic intracranial hemorrhage as either early or late stage. (author). 20 refs., 2 tabs., 6 figs

  18. MR appearance of hypothalamic hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, F.J.; Leibrock, L.G.; Huseman, C.A.; Makos, M.M.

    1988-02-01

    Hypothalamic hamartoma is the most common detectable cerebral lesion causing precocious puberty. Two histologically confirmed cases were studied by computerized tomography (CT) and magnetic resonance (MR) imaging. T2 weighted, sagittal MR images were superior to CT in delineating the tumor from surrounding grey matter. The lesion was isointense to grey matter on T1 weighted images allowing exclusion of other hypothalamic tumors. MR will undoubtedly become the imaging modality of choice in the detection of hypothalamic hamartoma.

  19. Localized 1H-MR spectroscopy in moyamoya disease before and after revascularization surgery

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Mee; Choi, Hye Young; Suh, Jung Soo [Ewha Womans University Hospital, Seoul (Korea, Republic of); Lee, Jung Hee; Lim, Keun Ho; Suh, Dae Chul; Lee, Ho Kyu; Lim, Tae Hwan; Ra, Young Shin [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-06-01

    To evaluate, using localized proton magnetic resonance spectroscopy (1H-MRS), the cerebral metabolic change apparent after revascularization surgery in patients with moyamoya disease. Sixteen children with moyamoya disease and eight age-matched normal controls underwent MR imaging, MR angiography, conventional angiography, and {sup 99m}Tc- ECD SPECT. Frontal white matter and the basal ganglia of both hemispheres were subjected to localized {sup 1}H-MRS, and after revascularization surgery, four patients underwent follow-up {sup 1}H-MRS. Decreased NAA/Cr ratios (1.35{+-}0.14 in patients vs. 1.55{+-}0.24 in controls) and Cho/Cr ratios (0.96{+-}0.13 in patients vs. 1.10{+-}0.11 in controls) were observed in frontal white matter. After revascularization surgery, NAA/Cr and Cho/Cr ratios in this region increased. In the basal ganglia, there is no abnormal metabolic ratios. Localized 1H-MRS revealed abnormal metabolic change in both hemispheres of children with moyamoya disease. Because of its non-invasive nature, {sup 1}H-MRS is potentially useful for the preoperative evaluation of metabolic abnormalities and their postoperative monitoring.

  20. Localized 1H-MR spectroscopy in moyamoya disease before and after revascularization surgery

    International Nuclear Information System (INIS)

    Lim, Soo Mee; Choi, Hye Young; Suh, Jung Soo; Lee, Jung Hee; Lim, Keun Ho; Suh, Dae Chul; Lee, Ho Kyu; Lim, Tae Hwan; Ra, Young Shin

    2003-01-01

    To evaluate, using localized proton magnetic resonance spectroscopy (1H-MRS), the cerebral metabolic change apparent after revascularization surgery in patients with moyamoya disease. Sixteen children with moyamoya disease and eight age-matched normal controls underwent MR imaging, MR angiography, conventional angiography, and 99m Tc- ECD SPECT. Frontal white matter and the basal ganglia of both hemispheres were subjected to localized 1 H-MRS, and after revascularization surgery, four patients underwent follow-up 1 H-MRS. Decreased NAA/Cr ratios (1.35±0.14 in patients vs. 1.55±0.24 in controls) and Cho/Cr ratios (0.96±0.13 in patients vs. 1.10±0.11 in controls) were observed in frontal white matter. After revascularization surgery, NAA/Cr and Cho/Cr ratios in this region increased. In the basal ganglia, there is no abnormal metabolic ratios. Localized 1H-MRS revealed abnormal metabolic change in both hemispheres of children with moyamoya disease. Because of its non-invasive nature, 1 H-MRS is potentially useful for the preoperative evaluation of metabolic abnormalities and their postoperative monitoring

  1. MR imaging of pineal cysts

    International Nuclear Information System (INIS)

    Ahn, Yong Sik; Yu, Hyeon; Kim, Wan Tae; Bae, Jin Woo; Moon, Hee Jung; Shin, Hyun Ja

    1999-01-01

    To evaluate the incidence and characteristic findings of pineal cyst incidentally detected on magnetic resonance (MR) imaging. Brain MR images obtained in 2432 patients were retrospectively reviewed to determine the incidence and MR findings of pineal cysts, which were evaluated according to their size, shape, location, signal intensity, interval change, contrast enhancement and mass effect on adjacent structures. Cysts were encountered in 107(4.4 %) of 2432 patients evaluated. their size ranged from 1 X 1 X 1 to 15 X 8 X 9 (mean, 5.97 X 3.82 X 4.82)mm. All were spherical (n=53) or oval (n=54) in shape. Their margin was smooth and they were homogeneous in nature. On T1-weighted images, the cysts were seen to be hyperintense (n=57) or isointense (n=50) to cerebrospinal fluid, but less so than brain parenchyma. T2-weighted images showed them to be isointense (n=51)or hyperintense (n=56) to cerebrospinal fluid. The cysts were centrally located in 65 cases and eccentrically in 42. Compression of the superior colliculi of the tectum was demonstrated in 17 cases (15.9 %). NO patients presented clinical symptoms or signs related to either pineal or tectal lesions. Peripheral enhancement around the cyst after Gd-DTPA injection was demonstrated in 51 cases(100 %). Follow-up examinations in 19 cases demonstrated no interval change. The incidence of pineal cysts was 4.4 %. The MR characteristics of simple pineal cysts include: (1) an oval or spherical shape, (2) a smooth outer margin and homogeneous nature, (3) isosignal or slightly high signal intensity to cerebrospinal fluid on whole pulse sequences, (4) ring enhancement after contrast injection, (5) an absence of interval change, as seen during follow up MR study. These MR appearances of pineal cysts might be helpful for differentiating them from pineal tumors

  2. Skeletal MR imaging: Correlation with skeletal scintigraphy

    International Nuclear Information System (INIS)

    Colletti, P.M.; Raval, J.K.; Ford, P.V.; Benson, R.C.; Kerr, R.M.; Boswell, W.D.; Siegel, M.E.; Ralls, P.W.

    1987-01-01

    Skeletal MR images bone marrow while skeletal scintigraphy uses bone metabolism to demonstrate abnormalities. The purpose of this paper is to correlate these MR and scintigraphic findings. T1 and T2 MR images at 0.5 T were correlated with planar bone scintigraphy (RN) using Tc-99m MDP in 56 patients. Of 23 cases with suspected spinal metastases, 19 were positive by MR imaging, 16 by RN. Individual lesions were shown better by MR imaging in five and by RN in two. These two cases had scoliosis, a potential difficulty with MR imaging. In 14 cases of suspected avascular necrosis (AVN), MR imaging was positive in 13 while RN was positive in ten. One negative case by RN had bilateral AVN by MR imaging. Four skull lesions shown easily by RN were seen only in retrospect on MR images. MR imaging is advantageous in evaluating bones with predominant marrow such as vertebrae or the femoral head, while RN is superior in areas primarily composed of cortical bone such as the skull

  3. MR cisternography after intrathecal Gd-DTPA application

    International Nuclear Information System (INIS)

    Reiche, Werner; Komenda, Yvonne; Steudel, Wolf-Ingo; Schick, Bernhard; Grunwald, Iris; Reith, Wolfgang

    2002-01-01

    The purpose of this study was to establish and to evaluate MR cisternography after intrathecal Gd-DTPA administration to detect rhinobasal cerebrospinal fluid (CSF) fistulae in patients with suspected CSF rhinorrhoea. Ten patients with suspected CSF rhinorrhoea were examined. The MR cisternography included the following investigation steps: acquisition of nonenhanced fat-suppressed T1-weighted spin-echo (SE) scans of the skull base and the paranasal sinuses, lumbar puncture with administration of 1 ml Gd-DTPA solute with 4 ml NaCl and performance of MR cisternography with the same fat-suppressed T1-weighted sequences as used initially. In 10 patients with suspected CSF rhinorrhoea Gd-DTPA enhanced MR cisternography detected 5 CSF fistulae. In 3 of 5 CSF leaks were located in the cribriform plate and in 2 of 5 sphenoidal. Whereas 4 of these depicted leaks were confirmed surgically, in 1 case the CSF fistula closed spontaneously. In another case, CSF leakage after severe head injury was clinically highly suspected but ceased prior to MR cisternography with inability to detect the temporary fistula. In the remaining 4 patients with serous rhinorrhoea MR cisternography did not provide any evidences for CSF fistulae. Intrathecal Gd-DTPA injection was tolerated excellently. Clinical and EEG examinations showed no gross behavioural or neurological disturbances and no seizure activity, respectively. The MR cisternography after intrathecal administration of Gd-DTPA represents a safe, promising and minimally invasive method for detection of CSF fistulae. This MR investigation provides excellent depiction of CSF spaces and pinpoints CSF fistulae. (orig.)

  4. MR appearance of central neurocytoma

    International Nuclear Information System (INIS)

    Chang, K.H.; Han, M.H.; Kim, D.G.; Chi, J.G.; Suh, D.C.; Kim, S.J.; Cha, S.H.; Han, M.C.

    1993-01-01

    To provide a detailed description of the MR appearances of central neurocytoma, MR images of 13 patients with central neurocytoma were retrospectively reviewed and compared with CT examinations. The histology was confirmed by ultrastructural and immunohistochemical studies. In 12 patients the tumors were histologically benign and located in the anterior part of the lateral ventricle, 6 of which extended to the 3rd ventricle. There was one case of a histologically malignant variant involving the thalamus and lateral ventricle. The tumors were primarily solid, but contained cysts (85%, 11/13), calcifications (69%, 9/13), and signal void from tumor vessels (62%, 8/13), frequently producing heterogeneous signal intensity on both T1- and T2-weighted images. Most of the solid portion appeared isointense or slightly hyperintense relative to the cerebral cortex on all MR pulse sequences. Calcifications were iso- or hypointense on MR, making them difficult to characterize with MR alone. Intratumoral hemorrhage was seen in 2 patients on MR but not on CT. Contrast enhancement was variable in degree and pattern. Coronal and sagittal MR images were valuable in evaluating the tumor extent and origin site, and in planning the surgical approach. It is concluded that MR imaging appears to be more useful than CT in the overall evaluation of central neurocytoma, even though calcification is better characterized with CT. (orig.)

  5. MR imaging of normal bone marrow

    International Nuclear Information System (INIS)

    Stajgis, M.; Paprzycki, W.

    1994-01-01

    Principles of MR bone marrow imaging on the basis of retrospective analysis of MR examinations of bone marrow in different anatomic sites in 200 patients have been discussed. Significance of different physiologic factors and processes such as age, steatosis, osteoporosis, conversion and reconversion, which influence on MR bone marrow images, have been emphasized. T1-weighted images obtained with spin-echo sequences give the most of information about bone marrow structure in MR. Thorough knowledge of bone marrow physiology and clinical status of the patient is indispensable in correct interpretation of hypointensive lesions on T1-weighted images. When presence of disseminated bone marrow disease is suspected, authors propose routine imaging of lumbar vertebral column, pelvis and proximal parts of femoral bones. (author)

  6. MR findings of brainstem injury

    Energy Technology Data Exchange (ETDEWEB)

    Park, Man Soo; Hwang, Woo Cheol; Park, Choong Ki [Hallym University College of Medicine, Seoul (Korea, Republic of); Suh, Dae Chul [University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Sang Joon [Dankook University of College of Medicine, Cheonan (Korea, Republic of)

    1995-02-15

    To analyze the characteristics of traumatic brainstem injury by CT and MR. CT and MR studies of 10 patients with traumatic brainstem lesion in MR were retrospectively reviewed, particularly attended to location, signal intensity and associated lesions. CT failed to depict 8 of 10 brainstem lesions. All lesions were detected in MR images with T2-weighted images showing higher detection rate (n = 10) (100%) than T1-weighted images (n = 3) (30%) or CT (n = 2) (20%). The brainstem lesions located in the dorsolateral aspects of the rostral brainstem (mid brain and upper pons) in 7 (70%) cases, in ventral aspects of rostral brain in 2 (20%) cases and in median portion of pons in 1 (10%) case. Corpus callosal (n = 5), lobar white matter (n = 5) diffuse axonal injury, and 2 hemorrhagic lesions in basal ganglia were the associated findings. MR imaging is more helpful than CT in the detection of brainstem injury, especially T2 weighted images. Primary brainstem lesions were typically located in the dorsolateral aspect of rostral brainstem (midbrain and upper pons). Corpus callosum and white matter lesions were frequently associated.

  7. Gadoxate-enhanced T1-weighted MR cholangiography: comparison of 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Koelblinger, C.; Schima, W.; Weber, M.; Mang, T.; Nemec, S.; Kulinna-Cosentini, C.; Bastati, N.; Ba-Ssalamah, A. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Univ. Wien (Austria)

    2009-06-15

    Purpose: to qualitatively and quantitatively compare gadoxate-enhanced T1-weighted MR cholangiography at magnetic field strengths of 1.5 T and 3.0 T. Materials and methods: a total of 40 patients with a non-dilated biliary system were retrospectively included in the study. T1-weighted MR cholangiography 20 min after IV administration of 0.025 mmol/kg gadoxate (Primovist trademark) was performed in 20 patients at 1.5 T and in another 20 patients at 3.0 T. Contrast-to-noise ratios (CNR) of the biliary system (common bile duct - CBD, right hepatic duct - RHD, left hepatic duct - LHD) compared to the periductal tissue were measured. Two radiologists also qualitatively assessed the visibility of the intrahepatic and extrahepatic biliary system using a six-point rating scale. The Mann-Whitney U-test and Pearson's correlation coefficient were used for statistical analysis. Results: the CNRs of the intrahepatic and extrahepatic hepatic bile ducts were significantly higher at 3.0 T. Qualitative analysis showed a significant superiority for 3.0 T in the delineation of the intrahepatic biliary system (RHD, LHD, segmental ducts). (orig.)

  8. Functional imaging of cerebral cortex activation with a 1.5-T MR imaging system

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Chang, Sun Ae; Ha, Choong Kun; Kim, Eun Sang; Kim, Hyung Jin; Chung, Sung Hoon

    1995-01-01

    Most of recent MR imagings of cerebral cortex activation have been performed by using high field magnet above 2-T or echo-planar imaging technique. We report our experience on imaging of cerebral cortex activation with a widely available standard 1.5-T MR. Series of gradient-echo images (TR/TE/flip angle: 80/60/40 .deg. 64 x 128 matrix) were acquired alternatively during the periods of rest and task in five normal volunteers. Finger movement (n = 10;5 right, 5 left) and flashing photic stimulation (n 1) were used as a motor task and a visual task to activate the motor cortex and visual cortex, respectively. Activation images were obtained by subtracting sum of rest images from that of task images. Changes of signal intensity were analyzed over the periods of rest and task. Activation images were obtained in all cases. Changes of signal intensity between rest and task periods were 6.5-14.6%(mean, 10.5%) in the motor cortex and 4.2% in the visual cortex. Functional imaging of cerebral cortex activation could be performed with a widely available 1.5-T MR. Widespread applications of this technique to basic and clinical neuroscience are expected

  9. Functional imaging of cerebral cortex activation with a 1.5-T MR imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyoung; Chang, Sun Ae; Ha, Choong Kun; Kim, Eun Sang; Kim, Hyung Jin; Chung, Sung Hoon [Gyeongsang National University, College of Medicine, Jeongju (Korea, Republic of)

    1995-07-15

    Most of recent MR imagings of cerebral cortex activation have been performed by using high field magnet above 2-T or echo-planar imaging technique. We report our experience on imaging of cerebral cortex activation with a widely available standard 1.5-T MR. Series of gradient-echo images (TR/TE/flip angle: 80/60/40 .deg. 64 x 128 matrix) were acquired alternatively during the periods of rest and task in five normal volunteers. Finger movement (n = 10;5 right, 5 left) and flashing photic stimulation (n 1) were used as a motor task and a visual task to activate the motor cortex and visual cortex, respectively. Activation images were obtained by subtracting sum of rest images from that of task images. Changes of signal intensity were analyzed over the periods of rest and task. Activation images were obtained in all cases. Changes of signal intensity between rest and task periods were 6.5-14.6%(mean, 10.5%) in the motor cortex and 4.2% in the visual cortex. Functional imaging of cerebral cortex activation could be performed with a widely available 1.5-T MR. Widespread applications of this technique to basic and clinical neuroscience are expected.

  10. Value of new MR techniques in MR-PET; Stellenwert neuer MR-Techniken in der MR-PET

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer klinische Radiologie und Nuklearmedizin, Mannheim (Germany); Quick, H.H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Institut fuer Medizinische Physik, Erlangen (Germany); Guimaraes, A. [Massachusetts General Hospital, Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown (United States); Catalano, O. [University of Naples Federico II, Naples (Italy); Morelli, J.N. [The Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore (United States)

    2013-12-15

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [German] Die klinische Implementierung der neuen Hybridtechnologie MR-Positronenemissionstomographie (MR-PET) bietet durch die Kombination aus hochaufloesender Morphologie, Funktion und Metabolismus bisher ungeahnte diagnostische Moeglichkeiten, die nicht nur fuer die Diagnose und die Verlaufskontrolle onkologischer und psychiatrischer Erkrankungen von hoher Bedeutung sind. Verglichen mit der PET-CT wird dies mit reduzierter Strahlenbelastung fuer den Patienten moeglich, was wiederum insbesondere fuer Patienten in der Tumornachsorge, die

  11. High-resolution MR imaging of the carpal tunnel and the wrist. Application of a 5-cm surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, J.; Bleschkowski, A.; Tempka, A.; Felix, R. [Medical Faculty of the Humboldt Univ., Berlin (Germany). Dept. of Radiology

    2000-07-01

    In order to make a comparative analysis of transversal tomograms obtained by high-resolution MR imaging with frozen cross-sections of an anatomical forearm specimen, twenty-two healthy volunteers were also examined using the same coil system to test for a range of possible clinical applications and for the depiction of morphological and morphometrical values of normal anatomy in vivo. MR images of the carpal tunnel of 22 healthy volunteers were obtained with a 1.5-T whole-body system with a 5-cm surface coil. Measurements were recorded with a field-of-view between 50x50 mm{sup 2} and 60x60 mm{sup 2} in a 256x256 pixel matrix for the T1 sequence. A slice thickness of 2 mm was used. The images were acquired using a T1-weighted SE sequence (TR/TE 500/38 ms) and a T2-weighted SE sequence (TR/TE 2000/70 ms). Additionally, a formalin-fixed anatomical forearm specimen was imaged for anatomic correlation. The imaged transversal cross-section levels in the specimen were subsequently freeze-sectioned. The anatomical structures of the MR findings were identified and compared with the macroscopical sections of the specimen. Based on the good depiction of details at this coil system with a pixel size in T1 of 0.195x0.195 mm, high-resolution MR imaging enabled identification of the interior structures of the carpal tunnel, as well as delineation of connective tissue. The clinical value of high-resolution MR includes the diagnosis of carpal tunnel syndrome and inflammatory disorders of the wrist. Our results support the feasibility of high-resolution MR imaging of the carpal tunnel and the wrist using small surface coils.

  12. High-resolution MR imaging of the carpal tunnel and the wrist. Application of a 5-cm surface coil

    International Nuclear Information System (INIS)

    Maurer, J.; Bleschkowski, A.; Tempka, A.; Felix, R.

    2000-01-01

    In order to make a comparative analysis of transversal tomograms obtained by high-resolution MR imaging with frozen cross-sections of an anatomical forearm specimen, twenty-two healthy volunteers were also examined using the same coil system to test for a range of possible clinical applications and for the depiction of morphological and morphometrical values of normal anatomy in vivo. MR images of the carpal tunnel of 22 healthy volunteers were obtained with a 1.5-T whole-body system with a 5-cm surface coil. Measurements were recorded with a field-of-view between 50x50 mm 2 and 60x60 mm 2 in a 256x256 pixel matrix for the T1 sequence. A slice thickness of 2 mm was used. The images were acquired using a T1-weighted SE sequence (TR/TE 500/38 ms) and a T2-weighted SE sequence (TR/TE 2000/70 ms). Additionally, a formalin-fixed anatomical forearm specimen was imaged for anatomic correlation. The imaged transversal cross-section levels in the specimen were subsequently freeze-sectioned. The anatomical structures of the MR findings were identified and compared with the macroscopical sections of the specimen. Based on the good depiction of details at this coil system with a pixel size in T1 of 0.195x0.195 mm, high-resolution MR imaging enabled identification of the interior structures of the carpal tunnel, as well as delineation of connective tissue. The clinical value of high-resolution MR includes the diagnosis of carpal tunnel syndrome and inflammatory disorders of the wrist. Our results support the feasibility of high-resolution MR imaging of the carpal tunnel and the wrist using small surface coils

  13. Rapid Precipitation of Amorphous Silica in Experimental Systems with Nontronite (NAu-1) and Shewanella oneidensis MR-1

    National Research Council Canada - National Science Library

    Furukawa, Yoko; O'Reilly, S. E

    2007-01-01

    ...) silica globule formation was confirmed in the immediate vicinity of bacterial cells and extracellular polymeric substances in all experimental systems that contained bacteria, whether the bacteria...

  14. MR imaging findings of acetabular dysplasia in adults

    Energy Technology Data Exchange (ETDEWEB)

    James, Steven; Connell, David [The Royal National Orthopaedic Hospital, Radiology Department, London, Middlesex (United Kingdom); Miocevic, Miranda; Malara, Frank; Pike, Jonathan [Victoria House Hospital, Radiology Department, Melbourne (Australia); Young, David [Melbourne Orthopaedic Group, Orthopaedic Surgery, Melbourne (Australia)

    2006-06-15

    To evaluate the diagnostic accuracy of MR imaging in the identification of labral and articular cartilage lesions in patients with acetabular dysplasia. Pre-operative MR imaging was performed on 27 hips in 25 consecutive patients (16 males, 9 females, age range 19-52 years, mean age 31.2 years) with radiographic evidence of acetabular dysplasia (centre-edge angle of Wiberg <20 degrees). The average duration of symptoms was 16.2 months. Two musculoskeletal radiologists assessed MR images in consensus for the presence of abnormality involving the acetabular labrum and adjacent acetabular articular cartilage. A high resolution, non-arthrographic technique was used to assess the labrum and labral chondral transitional zone. Surgical correlation was obtained in all cases by a single surgeon experienced in hip arthroscopy and ten patients with normal hip MRI were included to provide a control group. The acetabular labra in the dysplastic hips demonstrated abnormal signal intensity, and had an elongated appearance when compared with the control group (mean length 10.9 mm vs 6.4 mm). Morphological appearances in the labra included surface irregularity, fissures and cleft formation. MR imaging correctly identified the severity of chondral abnormality in 24 of 27 hips (89%) when compared with arthroscopic findings. MR imaging demonstrates an elongated labrum, focal intra-substance signal change and irregularity and fissuring of the margins in patients with acetabular dysplasia. Abnormality is also identified at the labral chondral transitional zone, where fissuring, focal clefts, chondral deficiency and subchondral cyst formation may be apparent. A high-resolution, non-arthrographic technique can provide an accurate preoperative assessment and evaluate the presence of premature osteoarthritis. (orig.)

  15. MR imaging findings of acetabular dysplasia in adults

    International Nuclear Information System (INIS)

    James, Steven; Connell, David; Miocevic, Miranda; Malara, Frank; Pike, Jonathan; Young, David

    2006-01-01

    To evaluate the diagnostic accuracy of MR imaging in the identification of labral and articular cartilage lesions in patients with acetabular dysplasia. Pre-operative MR imaging was performed on 27 hips in 25 consecutive patients (16 males, 9 females, age range 19-52 years, mean age 31.2 years) with radiographic evidence of acetabular dysplasia (centre-edge angle of Wiberg <20 degrees). The average duration of symptoms was 16.2 months. Two musculoskeletal radiologists assessed MR images in consensus for the presence of abnormality involving the acetabular labrum and adjacent acetabular articular cartilage. A high resolution, non-arthrographic technique was used to assess the labrum and labral chondral transitional zone. Surgical correlation was obtained in all cases by a single surgeon experienced in hip arthroscopy and ten patients with normal hip MRI were included to provide a control group. The acetabular labra in the dysplastic hips demonstrated abnormal signal intensity, and had an elongated appearance when compared with the control group (mean length 10.9 mm vs 6.4 mm). Morphological appearances in the labra included surface irregularity, fissures and cleft formation. MR imaging correctly identified the severity of chondral abnormality in 24 of 27 hips (89%) when compared with arthroscopic findings. MR imaging demonstrates an elongated labrum, focal intra-substance signal change and irregularity and fissuring of the margins in patients with acetabular dysplasia. Abnormality is also identified at the labral chondral transitional zone, where fissuring, focal clefts, chondral deficiency and subchondral cyst formation may be apparent. A high-resolution, non-arthrographic technique can provide an accurate preoperative assessment and evaluate the presence of premature osteoarthritis. (orig.)

  16. MR diffusion imaging and 1H spectroscopy in a child with medulloblastoma: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Wilke, M. [Max-Planck-Institute of Psychiatry, Muenchen (Germany). NMR Study Group; Eidenschink, A.; Mueller-Weihrich, S. [Technical Univ. of Muenchen, (Germany). Childrens' Hospital; Auer, D.P. [Max-Planck-Institute of Psychiatry, Muenchen (Germany). NMR Study Group

    2000-01-01

    We report on a child with a metastasising medulloblastoma which was assessed by MR diffusion imaging and 1H MR spectroscopy (MRS). Reduced mean apparent diffusion coefficients and a high amount of taurine could be demonstrated. This is the first reported case of high taurine in medulloblastoma in vivo and confirms earlier in vitro findings. It is suggested that the changes on diffusion imaging, possibly reflecting the small-cell histology of the tumour and high taurine in MRS, are indicative of medulloblastoma.

  17. MR diffusion imaging and 1H spectroscopy in a child with medulloblastoma: A case report

    International Nuclear Information System (INIS)

    Wilke, M.; Eidenschink, A.; Mueller-Weihrich, S.; Auer, D.P.

    2000-01-01

    We report on a child with a metastasising medulloblastoma which was assessed by MR diffusion imaging and 1H MR spectroscopy (MRS). Reduced mean apparent diffusion coefficients and a high amount of taurine could be demonstrated. This is the first reported case of high taurine in medulloblastoma in vivo and confirms earlier in vitro findings. It is suggested that the changes on diffusion imaging, possibly reflecting the small-cell histology of the tumour and high taurine in MRS, are indicative of medulloblastoma

  18. MR-guided lumbar sympathicolysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H. [Department of Diagnostic Radiology, University of Tuebingen (Germany); Schneider, Wilke [Department of Vascular Surgery, University of Tuebingen (Germany)

    2002-06-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  19. MR-guided lumbar sympathicolysis

    International Nuclear Information System (INIS)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H.; Schneider, Wilke

    2002-01-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  20. Brain MR imaging in systemic lupus erythematous

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Ae; Chang, Kee Hyun; Han, Moon Hee; Lee, Kyung Hwon; Kim, Sung Kwon; Lee, Jung Sang [Seoul National University College of Medicine, Seoul (Korea, Republic of); Cha, Sang Hoon [Chungbuk National University College of Medicine, Chungju (Korea, Republic of)

    1992-09-15

    To present MR imaging findings of intracranial lesions in systemic lupus erythematosus(SLE), a retrospective study was performed on MR images of 33 SLE patients with neurologic symptoms and signs. MR imaging was performed on either a 0.5 T (21 patients) or 2.0 T unit (12 patients), using T1-weighted, proton-density-weighted, and T2-weighted spin echo sequences in all patients. In seven patients, post-contrast T1-weighted images were also obtained after administration of gadopentetate dimeglumine. The main MR findings consisted of focal lesions suggesting ischemia/infarct (15 patients), diffuse brain atrophy (8), and findings associated with infection (4). The MR findings were normal in 11 patients (33%). The focal lesions suggesting ischemia/infarcts presumably secondary to vasculitis were distributed in the cortex or subcortical white matter (7 patients), deep periventricular white matter (3), or in both areas (5). Most of the focal lesions were multiple and small in size. The findings associated with infection were variable and included communicating hydrocephalus, meningeal enhancement, granuloma, etc. MR findings of SLE were non-specific and therefore clinical correlation is needed when evaluating SLE in MR.

  1. Redox Sensing within the Genus Shewanella

    Directory of Open Access Journals (Sweden)

    Howard W. Harris

    2018-01-01

    Full Text Available A novel bacterial behavior called congregation was recently described in Shewanella oneidensis MR-1 as the accumulation of cells around insoluble electron acceptors (IEA. It is the result of a series of “run-and-reversal” events enabled by modulation of swimming speed and direction. The model proposed that the swimming cells constantly sense their surroundings with specialized outer membrane cytochromes capable of extracellular electron transport (EET. Up to this point, neither the congregation nor attachment behavior have been studied in any other strains. In this study, the wild type of S. oneidensis MR-1 and several deletion mutants as well as eight other Shewanella strains (Shewanella putrefaciens CN32, S. sp. ANA-3, S. sp. W3-18-1, Shewanella amazonensis SB2B, Shewanella loihica PV-4, Shewanella denitrificans OS217, Shewanella baltica OS155, and Shewanella frigidimarina NCIMB400 were screened for the ability to congregate. To monitor congregation and attachment, specialized cell-tracking techniques, as well as a novel cell accumulation after photo-bleaching (CAAP confocal microscopy technique were utilized in this study. We found a strong correlation between the ability of strain MR-1 to accumulate on mineral surface and the presence of key EET genes such as mtrBC/omcA (SO_1778, SO_1776, and SO_1779 and gene coding for methyl-accepting protein (MCPs with Ca+ channel chemotaxis receptor (Cache domain (SO_2240. These EET and taxis genes were previously identified as essential for characteristic run and reversal swimming around IEA surfaces. CN32, ANA-3, and PV-4 congregated around both Fe(OH3 and MnO2. Two other Shewanella spp. showed preferences for one oxide over the other: preferences that correlated with the metal content of the environments from which the strains were isolated: e.g., W3-18-1, which was isolated from an iron-rich habitat congregated and attached preferentially to Fe(OH3, while SB2B, which was isolated from a MnO2-rich

  2. Quantitative 1H MR spectroscopy of the brain in patients with congestive heart failure before and after cardiac transplantation

    International Nuclear Information System (INIS)

    Lim, Soo Mee; Lee, Ho Kyu; Choi, Choong Gon; Lim, Tae Hwan; Lee, Jung Hee

    1999-01-01

    To evaluate the effects of cardiac transplantation on the brain in patients with congestive heart failure (CHF), using quantitative 1 H MR spectroscopy ( 1 H-MRS). Ten patients with CHF underwent MRI and quantitative 1 H-MRS before and 1-2 and 4-9 months after cardiac transplantation. MR spectra were obtained from parietal white matter (PWM) and occipital gray matter (OGM) using PROBE (PROton Brain Exam). Changes in MR signal intensity were evaluated, and the cerebral metabolic concentrations in PWM and OGM were compared. For comparative purposes, 20 normal volunteers were included. No abnormal MR signal intensity was seen in the brain before or after cardiac transplantation. Changes in cerebral metabolic concentrations were observed on 1 H-MRS; concentrations of creatine (Cr) in PWM, and of N-acetylacepartate (NAA), Cr and myo-Inositol(mI) in OGM were significantly lower before transplantation. After successful transplantation, Cr levels returned to their normal range in PWM and OGM, while a slightly increase choline (Cho) level was observed in PWM. Cerebral hypoperfusion in CHF can be evaluated using 1 H-MRS. MRS may play a substantial role in monitoring the effect of cardiac transplantation

  3. Nontraumatic spinal epidural hematomas. MR features

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Baumgartner, R.W.; Zambaz, B.D.; Remonda, L.; Ozdoba, C.; Schroth, G.

    1997-01-01

    Purpose: Spinal epidural hematoma (SEH) is a rare clinical entity with a bleak outcome. The aim of our study was to establish the value of MR findings in the diagnosis of nontraumatic SEH. Material and Methods: Seven patients with nontraumatic SEH were examined by MR at 1.5 T. Two patients were under anticoagulation therapy with heparin, and 2 others were taking salicylic acid. One patient had lupus erythematodes with a marked thrombocytopenia. One patient had a spinal arteriovenous malformation. Results: MR imaging permitted the accurate localization of extradural intraspinal expansive lesions which exhibited the characteristic signal intensities of blood. Five patients underwent laminectomy and evacuation of the hematoma. In the acute phase, the hematomas appeared isointense when compared with the spinal cord on T1-weighted images and hyperintense on T2-weighted images. Later the hematomas were hyperintense on T1-weighted images and showed signals identical to those of cerebrospinal fluid (CSF) on T2-weighted images. Conclusion: MR imaging established the exact diagnosis and localization of SEH in all cases. MR also can provide useful information about the age of the hematomas. (orig.)

  4. MR imaging and histopathology of cartilage tumors

    Energy Technology Data Exchange (ETDEWEB)

    Mizutani, Hirokazu; Ohba, Satoru; Ohtsuka, Takanobu; Matui, Norio; Nakamura, Takaaki (Nagoya City Univ. (Japan). Faculty of Medicine)

    1994-05-01

    The MR imaging-pathologic correlation of cartilaginous bone tumors and the value of intravenously administered Gd-DTPA enhanced MR imaging was studied. The MR studies were retrospectively reviewed. Thirty-seven cases were examined with 0.5 T and 1.0 T scanner and all cases were pathologically proved. We discussed the following MR findings: signal intensities of tumors, Gd-DTPA features, morphological findings, and associated findings. Hyaline cartilage tumors showed low signal intensity on T[sub 1]-weighted images and very high signal intensity on T[sub 2]-weighted images. Lobulated marginal enhancements were recognized in chondrosarcomas. This may be an important finding to suspect chondrosarcoma. (author).

  5. Generation of structural MR images from amyloid PET: Application to MR-less quantification.

    Science.gov (United States)

    Choi, Hongyoon; Lee, Dong Soo

    2017-12-07

    Structural magnetic resonance (MR) images concomitantly acquired with PET images can provide crucial anatomical information for precise quantitative analysis. However, in the clinical setting, not all the subjects have corresponding MR. Here, we developed a model to generate structural MR images from amyloid PET using deep generative networks. We applied our model to quantification of cortical amyloid load without structural MR. Methods: We used florbetapir PET and structural MR data of Alzheimer's Disease Neuroimaging Initiative database. The generative network was trained to generate realistic structural MR images from florbetapir PET images. After the training, the model was applied to the quantification of cortical amyloid load. PET images were spatially normalized to the template space using the generated MR and then standardized uptake value ratio (SUVR) of the target regions was measured by predefined regions-of-interests. A real MR-based quantification was used as the gold standard to measure the accuracy of our approach. Other MR-less methods, a normal PET template-based, multi-atlas PET template-based and PET segmentation-based normalization/quantification methods, were also tested. We compared performance of quantification methods using generated MR with that of MR-based and MR-less quantification methods. Results: Generated MR images from florbetapir PET showed visually similar signal patterns to the real MR. The structural similarity index between real and generated MR was 0.91 ± 0.04. Mean absolute error of SUVR of cortical composite regions estimated by the generated MR-based method was 0.04±0.03, which was significantly smaller than other MR-less methods (0.29±0.12 for the normal PET-template, 0.12±0.07 for multiatlas PET-template and 0.08±0.06 for PET segmentation-based methods). Bland-Altman plots revealed that the generated MR-based SUVR quantification was the closest to the SUVR values estimated by the real MR-based method. Conclusion

  6. MR-guided facet joint injection therapy using an open 1.0-T MRI system: an outcome study

    International Nuclear Information System (INIS)

    Freyhardt, Patrick; Bucourt, Maximilian de; Maurer, Martin; Renz, Diane; Gebauer, Bernhard; Hamm, Bernd; Streitparth, Florian; Hartwig, Tony; Teichgraeber, Ulf K.M.

    2013-01-01

    To evaluate the accuracy, safety and efficacy of magnetic resonance imaging (MRI)-guided facet joint injection therapy using a 1.0-T open MRI. One hundred and sixty-six facet joint blocks in 45 patients with lower back pain were performed under MR fluoroscopic guidance using a proton-density-weighted turbo-spin-echo sequence. An in-room monitor, wireless MR-mouse for operator-controlled multiplanar navigation, a flexible surface coil and MR-compatible 20-G needle were used. Clinical outcome was evaluated by questionnaire before intervention and after 1 week, 3, 6 and 12 months using a numerical visual analogue scale (VAS). All facet joint blocks were considered technically successful with distribution of the injectant within and/or around the targeted facet joint. No major complications occurred. The final outcome analysis included 38 patients. An immediate effect was reported by 63 % of the patients. A positive mid-/long-term effect was seen in 13 patients (34 %) after 6 months and in 9 patients (24 %) after 12 months. Mean VAS was reduced from 7.1 ± 1.7 (baseline) to 3.5 ± 2.2, 4.1 ± 3.0, 3.8 ± 2.9 and 4.6 ± 2.9 at 1 week, 3, 6 and 12 months (P < 0.01). MR-guided facet joint injection therapy of the lumbosacral spine is accurate, safe and efficient in the symptomatic treatment of lower back pain. (orig.)

  7. Intracranial tuberculoma: MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, P; Zenteno, M A; Rodriguez-Carbajal, J; Brutto, O.H. del; Talamas, O

    1989-09-01

    MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially for brainstem tuberculomas. Nevertheless, the potential role for MR diagnosis of intracranial tuberculoma is limited by the fact that other infectious or neoplasic diseases may present similar findings. The diagnosis of intracranial tuberculoma should rest on a proper integration of data from clinical manifestations, cerebrospinal fluid analysis, and neuroimaging studies. (orig.).

  8. Intracranial tuberculoma: MR imaging

    International Nuclear Information System (INIS)

    Salgado, P.; Zenteno, M.A.; Rodriguez-Carbajal, J.; Brutto, O.H. del; Talamas, O.

    1989-01-01

    MR studies of 6 patients with intracranial tuberculoma are reviewed. All patients also underwent CT scans which showed hypo- or isodense lesions with abnormal enhancement following contrast administration. MR showed lesions with prolongation of the T1 relaxation time in every case. On the T2-weighted sequences, the signal properties of the tuberculoma varied according to the stage of evolution of the lesion. Incipient tuberculomas appeared as scattered areas of hypointensity surrounded by edema. Mature tuberculomas were composed of a dark necrotic center surrounded by an isointense capsule which was, in turn, surrounded by edema. In one patient, the center of the lesion was hyperintense probably because of liquefaction and pus formation (tuberculous abscess). While both, CT and MR, were equally sensitive in visualizing the intracranial tuberculoma in every patient, MR was slightly superior in demonstrating the extent of the lesion, especially for brainstem tuberculomas. Nevertheless, the potential role for MR diagnosis of intracranial tuberculoma is limited by the fact that other infectious or neoplasic diseases may present similar findings. The diagnosis of intracranial tuberculoma should rest on a proper integration of data from clinical manifestations, cerebrospinal fluid analysis, and neuroimaging studies. (orig.)

  9. Diffusion-weighted MR imaging findings in carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Teksam, M.; Casey, S.O.; Michel, E.; Liu, H.; Truwit, C.L.

    2002-01-01

    Diffusion-weighted MR imaging (DWI) of two patients with carbon monoxide (CO) poisoning demonstrated white matter and cortical hyperintensities. In one patient, the changes on the FLAIR sequence were more subtle than those on DWI. The DWI abnormality in this patient represented true restriction. In the second patient, repeated exposure to CO caused restricted diffusion. DWI may be helpful for earlier identification of the changes of acute CO poisoning. (orig.)

  10. T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); UMR INSERM 965, Hôpital Lariboisière, 2 Rue Amboise Paré, 75010 Paris (France); Gavini, Jean-Philippe, E-mail: jpgavini@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Placé, Vinciane, E-mail: vinciane.place@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Sebbag, Delphine, E-mail: delphinesebbag@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Vignaud, Alexandre, E-mail: alexandre.vignaud@cea.fr [LRMN, Neurospin, CEA-SACLAY, Bâtiment 145, 91 191 Gif-sur-Yvette Cedex (France); and others

    2013-11-01

    Objective: To qualitatively and quantitatively compare T2-weighted MR imaging of the liver using volumetric spin-echo with sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) with conventional turbo spin-echo (TSE) sequence for fat-suppressed T2-weighted MR imaging of the liver. Materials and methods: Thirty-three patients with suspected focal liver lesions had SPACE MR imaging and conventional fat-suppressed TSE MR imaging. Images were analyzed quantitatively by measuring the lesion-to-liver contrast-to-noise ratio (CNR), and the signal-to-noise ratio (SNR) of main focal hepatic lesions, hepatic and splenic parenchyma and qualitatively by evaluating the presence of vascular, respiratory motion and cardiac artifacts. Wilcoxon signed rank test was used to search for differences between the two sequences. Results: SPACE MR imaging showed significantly greater CNR for focal liver lesions (median = 22.82) than TSE MR imaging (median = 14.15) (P < .001). No differences were found for SNR of hepatic parenchyma (P = .097), main focal hepatic lesions (P = .35), and splenic parenchyma (P = .25). SPACE sequence showed less artifacts than TSE sequence (vascular, P < .001; respiratory motion, P < .001; cardiac, P < .001) but needed a longer acquisition time (228.4 vs. 162.1 s; P < .001). Conclusion: SPACE MR imaging provides a significantly increased CNR for focal liver lesions and less artifacts by comparison with the conventional TSE sequence. These results should stimulate further clinical studies with a surgical standard of reference to compare the two techniques in terms of sensitivity for malignant lesions.

  11. Clinical Proton MR Spectroscopy in Central Nervous System Disorders

    Science.gov (United States)

    Alger, Jeffry R.; Barker, Peter B.; Bartha, Robert; Bizzi, Alberto; Boesch, Chris; Bolan, Patrick J.; Brindle, Kevin M.; Cudalbu, Cristina; Dinçer, Alp; Dydak, Ulrike; Emir, Uzay E.; Frahm, Jens; González, Ramón Gilberto; Gruber, Stephan; Gruetter, Rolf; Gupta, Rakesh K.; Heerschap, Arend; Henning, Anke; Hetherington, Hoby P.; Howe, Franklyn A.; Hüppi, Petra S.; Hurd, Ralph E.; Kantarci, Kejal; Klomp, Dennis W. J.; Kreis, Roland; Kruiskamp, Marijn J.; Leach, Martin O.; Lin, Alexander P.; Luijten, Peter R.; Marjańska, Małgorzata; Maudsley, Andrew A.; Meyerhoff, Dieter J.; Mountford, Carolyn E.; Nelson, Sarah J.; Pamir, M. Necmettin; Pan, Jullie W.; Peet, Andrew C.; Poptani, Harish; Posse, Stefan; Pouwels, Petra J. W.; Ratai, Eva-Maria; Ross, Brian D.; Scheenen, Tom W. J.; Schuster, Christian; Smith, Ian C. P.; Soher, Brian J.; Tkáč, Ivan; Vigneron, Daniel B.; Kauppinen, Risto A.

    2014-01-01

    A large body of published work shows that proton (hydrogen 1 [1H]) magnetic resonance (MR) spectroscopy has evolved from a research tool into a clinical neuroimaging modality. Herein, the authors present a summary of brain disorders in which MR spectroscopy has an impact on patient management, together with a critical consideration of common data acquisition and processing procedures. The article documents the impact of 1H MR spectroscopy in the clinical evaluation of disorders of the central nervous system. The clinical usefulness of 1H MR spectroscopy has been established for brain neoplasms, neonatal and pediatric disorders (hypoxia-ischemia, inherited metabolic diseases, and traumatic brain injury), demyelinating disorders, and infectious brain lesions. The growing list of disorders for which 1H MR spectroscopy may contribute to patient management extends to neurodegenerative diseases, epilepsy, and stroke. To facilitate expanded clinical acceptance and standardization of MR spectroscopy methodology, guidelines are provided for data acquisition and analysis, quality assessment, and interpretation. Finally, the authors offer recommendations to expedite the use of robust MR spectroscopy methodology in the clinical setting, including incorporation of technical advances on clinical units. © RSNA, 2014 Online supplemental material is available for this article. PMID:24568703

  12. MR imaging and MR spectroscopy for characterization of cardiomyopathies in adolescents - preliminary results

    International Nuclear Information System (INIS)

    Beer, M.; Buchner, S.; Fuchs, J.; Machann, W.; Ritter, C.O.; Beissert, M.; Darge, K.; Hahn, D.; Koestler, H.; Wirbelauer, J.

    2007-01-01

    Purpose: Cardiomyopathy is a rare but life-threatening disease in children and adolescents. Recent studies reported morphological, functional or metabolic alterations of the heart. We discuss a combined MR imaging and 31 P MR spectroscopy (MRS) protocol allowing the analysis of interdependencies between these parameters. Since normal values of cardiac MR parameters in this age group are not available, we included studies of age-matched healthy adolescents. Materials and Methods: 2D-CINE was used to assess left ventricular (LV) parameters. Additional 3D-Chemical Shift Imaging (3D-CSI) and Spectral Localization with Optimal Pointspread Function (SLOOP) reconstruction allowed quantification of the cardiac energy metabolism. Patients (n = 4; all male; age 16.8 ± 2.9 years) were included on the basis of an echocardiographic diagnosis of possible cardiomyopathy. The same protocol was applied to healthy young volunteers (n = 4; 1 female, 3 male; age 15.5 ± 0.6 years). Results: The patients had a significantly higher LV mass index compared to the control group (147 ± 41 g/m2 versus 97 ± 16 g/m2; p = 0.04). The other LV parameters (including LV EF with 59 ± 22 % versus 67 ± 10 %) showed no significant differences. The phosphocreatine to adenosine triphosphate ratio (PCr/ATP-ratio) of the patients was reduced to 1.71 ± 0.40 versus 2.44 ± 0.30 (p = 0.01), combined with a tendency towards decreased PCr concentrations of 9.1 ± 2.5 versus 7.9 ± 1.0 mmol/kg. Conclusion: The combination of 31 P MR spectroscopy and MR imaging allows quantitative determination of morphologic, functional and metabolic alterations in adolescents with suspected cardiomyopathy in one examination procedure. The reduction of energy metabolism combined with unaltered global function may indicate a primary role of metabolism in the pathogenesis of cardiomyopathies in adolescents. (orig.)

  13. Breast MR imaging: correlation of high resolution dynamic MR findings with prognostic factors

    International Nuclear Information System (INIS)

    Lee, Shin Ho; Cho, Nariya; Chung, Hye Kyung; Kim, Seung Ja; Cho, Kyung Soo; Moon, Woo Kyung; Cho, Joo Hee

    2005-01-01

    We wanted to correlate the kinetic and morphologic MR findings of invasive breast cancer with the classical and molecular prognostic factors. Eighty-seven patients with invasive ductal carcinoma NOS underwent dynamic MR imaging at 1.5 T, and with using the T1-weighted 3D FLASH technique. The morphologic findings (shape, margin, internal enhancement of the mass or the enhancement distribution and the internal enhancement of any non-mass lesion) and the kinetic findings (the initial phase and the delayed phase of the time-signal. Intensity curve) were interpreted using a ACR BI-RADS-MRI lexicon. We correlate MR findings with histopathologic prognostic factors (tumor size, lymph node status and tumor grade) and the immunohistochemically detected biomarkers (ER, PR, ρ 53, c-erbB-2, EGFR and Ki-67). Univariate and multivariate statistical analyses were than performed. Among the MR findings, a spiculated margin, rim enhancement and washout were significantly correlated with the prognostic factors. A spiculated margin was independently associated with the established predictors of a good prognosis (a lower histologic and nuclear grade, positive ER and PR) and rim enhancement was associated with a poor prognosis (a higher histologic and nuclear grade, negative ER and PR). Wash out was a independent predictor of Ki-67 activity. Some of the findings of high resolution dynamic MR imaging were associated with the prognostic factors, and these findings may predict the prognosis of breast cancer

  14. Accuracy evaluation of fusion of CT, MR, and SPECT images using commercially available software packages (SRS PLATO and IFS)

    International Nuclear Information System (INIS)

    Mongioj, Valeria; Brusa, Anna; Loi, Gianfranco; Pignoli, Emanuele; Gramaglia, Alberto; Scorsetti, Marta; Bombardieri, Emilio; Marchesini, Renato

    1999-01-01

    Purpose: A problem for clinicians is to mentally integrate information from multiple diagnostic sources, such as computed tomography (CT), magnetic resonance (MR), and single photon emission computed tomography (SPECT), whose images give anatomic and metabolic information. Methods and Materials: To combine this different imaging procedure information, and to overlay correspondent slices, we used commercially available software packages (SRS PLATO and IFS). The algorithms utilize a fiducial-based coordinate system (or frame) with 3 N-shaped markers, which allows coordinate transformation of a clinical examination data set (9 spots for each transaxial section) to a stereotactic coordinate system. The N-shaped markers were filled with fluids visible in each modality (gadolinium for MR, calcium chloride for CT, and 99m Tc for SPECT). The frame is relocatable, in the different acquisition modalities, by means of a head holder to which a face mask is fixed so as to immobilize the patient. Position errors due to the algorithms were obtained by evaluating the stereotactic coordinates of five sources detectable in each modality. Results: SPECT and MR position errors due to the algorithms were evaluated with respect to CT: Δx was ≤ 0.9 mm for MR and ≤ 1.4 mm for SPECT, Δy was ≤ 1 mm and ≤ 3 mm for MR and SPECT, respectively. Maximal differences in distance between estimated and actual fiducial centers (geometric mismatch) were in the order of the pixel size (0.8 mm for CT, 1.4 mm for MR, and 1.8 mm for SPECT). In an attempt to distinguish necrosis from residual disease, the image fusion protocol was studied in 35 primary or metastatic brain tumor patients. Conclusions: The image fusion technique has a good degree of accuracy as well as the potential to improve the specificity of tissue identification and the precision of the subsequent treatment planning

  15. High-field-strength MR imaging of endometriosis

    International Nuclear Information System (INIS)

    Zawin, M.; McCarthy, S.M.; Comite, F.

    1987-01-01

    Twelve women with proven endometriosis were evaluated with MR imaging, utilizing a 1.5-T system. Axial and sagittal T1, proton density, and T2-weighted images were acquired. Laparoscopies were performed within a 1-month interval of the study in all cases. MR imaging accurately identified seven endometriomas but missed lesions in two cases. Areas with endometriotic implants were accurately localized five cases. The authors conclude that MR imaging is extremely useful in identifying sites of endometriosis and, therefore, promises to obviate repeated laparoscopies to monitor patients' response to therapy

  16. Indirect MR arthrography in the evaluation of tears of the glenoid labrum; Indirekte MR-Arthrographie in der Diagnostik von Laesionen des Labrum glenoidale

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Vahlensieck, M.; Lutterbey, G.; Pauleit, D.; Kreft, B.; Keller, E.; Schild, H. [Radiologische Universitaetsklinik Bonn (Germany); Wallny, T. [Orthopaedische Universitaetsklinik Bonn (Germany); Steuer, K.; Golombek, V. [Klinik fuer Unfallchirurgie, Univ. Bonn (Germany)

    1997-07-01

    Purpose: It has been shown that intravenous administration of contrast media produces an MR arthrographic effect without the need for intraarticular injection. This is the first study evaluating this new technique of indirect MR arthrography in the diagnosis of glenoid labrum tears. Methods: 28 patients with clinically suspected labral injuries were prospectively investigated (1.5 Tesla, flexible surface coil). A plain MR examination of the shoulder (transverse and oblique-coronal orientation, T{sub 1}-weighted spin- [T{sub E}/T{sub R} 15/675], proton density- and T{sub 2}*-weighted gradient echo [T{sub E}/T{sub R}/Flip 14,32/600/30 ] sequences) and indirect MR arthrography (transverse and oblique-coronal orientation, fat-suppressed T{sub 1}-weighted spin-echo sequences [T{sub E}/T{sub R} 15/675], intravenous injection of gadopentetate dimeglumine [0.1 mmol/kg], followed by 10-15 min of joint movement) were performed. Results were confirmed by arthroscopy and/or open surgery. Results: Indirect MR arthrography significantly improved delineation of the glenoid labrum and hyaline cartilage (p<0.05). Sensitivity and specificity of indirect MR arthrography in the diagnosis of labral injuries were 90% and 89%, compared to 79% and 67% of the native MR examination. Conclusion: Indirect MR arthrography is a promising non-invasive technique in the evaluation of the glenoid labrum. (orig.) [Deutsch] Ziel: In frueheren Studien wurde gezeigt, dass die intravenoese Injektion gadoliniumhaltiger Kontrastmittel zur Signalintensitaetssteigerung im Gelenkkavum fuehrt. In dieser Studie wurde erstmals diese Technik der indirekten MR-Arthrographie am Schultergelenk in der Diagnostik von Labrumlaesionen evaluiert. Methode: 28 Patienten mit klinischem Verdacht auf eine Verletzung des Labrum glenoidale und/oder der Rotatorenmanschette wurden prospektiv nach folgendem Protokoll an einem 1,5-Tesla-System mit einer Oberflaechen-Ringspule untersucht: 1. Native MR-Standard-Untersuchung mit

  17. Gadolinium-enhanced excretory MR urography: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lee, Jeong Min; Han, Young Min; Cheong, Gyung Ho; Oh, Hee Sul; Kim, Chong Soo; Park, Sung Kwang; Kim, Young Gon

    2000-01-01

    To compare the feasibility of gadolinium-enhanced excretory MR urography (GEMRU) and conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in patients with hydronephrosis or non-visualized kidney. Fifteen patients with hydronephrosis or non-visualized kidney, as demonstrated by ultrasonography or intravenous urography, were enrolled in this study. Nine were men and six were women, and their age ranged from 18 to 77 (mean, 60.6) years. For all MR examinations, a 1.5T MR unit was employed. For breath-hold MR urography, the HASTE technique (MRU) was used, and reconstruction involved the use of a maximum intensity-projection (MIP) algorithm. For gadolinium-enhanced excretory MR urography, the fast low angle shot (FLASH) 3-D method was used and images were obtained at 5, 10, 20, and 30 minutes, and reconstruction again involved the use of MIP algorithm. In some cases, additional GEMRU was obtained 24 hour after contrast material injection, and an MIP algorithm was used for reconstruction. MRU and GEMRU were independently interpreted by two radiologists who for quantitative analysis compared SNR with CNR, and at each anatomic level qualitatively analyzed morphologic accuracy and diagnostic value of the lesions. In quantitative analysis, SNR and CNR differences between the two sequences at the renal pelvis and the level of the ureter were not significant (p greater than 0.05). In qualitative analysis, GEMRU was superior to MRU for the assessment of evaluated ureter at each level (p less than 0.05), anatomic anomaly and intrinsic tumor. Ureteral stones, however, were more easily diagnosed with MRU. For assessment of the ureter GEMRU is superior to MRU and has the advantage of evaluating renal function. We believe that for evaluation of the urinary tract, especially the distal ureter, GEMRU may be a valuable adjunct to routine MR urography. (author)

  18. MR imaging of acute subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Spickler, E.; Lufkin, R.B.; Frazee, J.; Lylyk, P.; Vinuela, F.; Bentson, J.R.; Dion, J.E.

    1987-01-01

    Subarachnoid hemorrhage was produced in four Macaca nemestrina monkeys using the technique of Frazee. CT and MR imaging were performed immediately after the procedure and at frequent intervals up to 2 weeks after hemorrhage. The imaging studies were compared with clinical evaluations and pathologic specimens of all animals. Additional human clinical CT/MR studies of subarachnoid hemorrhage were also studied. Acute hemorrhage was recognized on MR as an increase in signal in the region of clot compared with surrounding cerebrospinal fluid. This most likely reflects T1 shortening due to proton binding rather than a pure paramagnetic effect. While CT is sensitive to the hemoglobin protein in acute hemorrhage, the superior resolution of the basal cisterns on MR images results in equal or better definition of acute subarachnoid hemorrhage on MR in many cases

  19. MR imaging of prostate cancer

    International Nuclear Information System (INIS)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A.; Mueller-Lisse, U.G.; Massmann, J.

    2003-01-01

    Accurate diagnosis and staging of prostate cancer (PC) is developing into an important health care issue in light of the high incidence of PC and the improvements in stage-adapted therapy. The purpose of this paper is to provide an overview on the current role of MR imaging and MR spectroscopy in the diagnosis and staging of PC.Material and methods Pertinent literature was searched and evaluated to collect information on current clinical indications, study techniques, diagnostic value, and limitations of magnetic resonance imaging and spectroscopy. Major indications for MR imaging of patients with supected PC are to define tumor location before biopsy when clinical or TRUS findings are inconclusive, and to provide accurate staging of histologically proven PC to ascertain effective therapy. Current MR imaging techniques for the evaluation of PC include multiplanar high-resolution T2-weighted FSE and T1-weighted SE sequences using combined endorectal and phased-array coils. Using these techniques, the reported accuracy of MR imaging for the diagnosis of extracapsular tumor extension ranges between 82 and 88% with sensitivities between 80 and 95%, and specificities between 82 and 93%. Typical MR findings of PC in different stages of disease, as well as diagnostic problems, such as chronic prostatitis, biopsy-related hemorrhage and therapy-related changes of prostatic tissue are discussed. In addition, the current perspectives and limitations of MR spectroscopy in PC are summarized. Current MR imaging techniques provide important diagnostic information in the pretherapeutic workup of PC including a high staging accuracy, and is superior to TRUS. (orig.) [de

  20. MR findings of wernicke encephalopathy

    International Nuclear Information System (INIS)

    Yoon, Hyun Ki; Chang, Kee Hyun; Lee, Goo; Han, Moon Hee; Park, Sung Ho; Na, Duk Yull; Song, Chi Sung

    1991-01-01

    Seven patients (33 to 58 years old) with clinical diagnoses of Wernicke encephalopathy were examined with MR on either a 2.0T (5 cases) or a 0.5T scanner (2 cases) using spin-echo pulse sequences. In 2 patients, follow-up MR studies were performed 1 and 5 weeks after thiamine (vitamine B1) treatment. Five patients (4 chronic alcoholics and 1 with hyperemesis gravidarum) showed atrophy of both mamillary bodies, along with patchy lesions around the third ventricle, medial thalami, tectum of the midbrain, and periaqueductal gray matter. Another patient with hyperemesis of gravidrum demonstrated only slightly atrophic mamillary bodies, and the last patient with severe vomiting after gastrojejunostomy showed only diencephaic/mesencephalic lesions with apparently normal mamillary bodies. A follow-up MR showed a decrease in previously-noted diencephalic/-/mesencephalic lesions but no change in the size of the mamillary bodies. Diencephalic/mesencephalic lesions were well seen as a high-signal intensity on proton-and T2-weighted axial images, while atrophy of the mamillary bodies was seen best on T1-weighted sagittal images. MR imaging is very useful in demonstrating the characteristic lesions of Wernicke encephalopathy and in evaluating the result of treatment on follow-up study

  1. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  2. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  3. Hippocampal MR volumetry

    Science.gov (United States)

    Haller, John W.; Botteron, K.; Brunsden, Barry S.; Sheline, Yvette I.; Walkup, Ronald K.; Black, Kevin J.; Gado, Mokhtar; Vannier, Michael W.

    1994-09-01

    Goal: To estimate hippocampal volumes from in vivo 3D magnetic resonance (MR) brain images and determine inter-rater and intra- rater repeatability. Objective: The precision and repeatability of hippocampal volume estimates using stereologic measurement methods is sought. Design: Five normal control and five schizophrenic subjects were MR scanned using a MPRAGE protocol. Fixed grid stereologic methods were used to estimate hippocampal volumes on a graphics workstation. The images were preprocessed using histogram analysis to standardize 3D MR image scaling from 16 to 8 bits and image volumes were interpolated to 0.5 mm3 isotropic voxels. The following variables were constant for the repeated stereologic measures: grid size, inter-slice distance (1.5 mm), voxel dimensions (0.5 mm3), number of hippocampi measured (10), total number of measurements per rater (40), and number of raters (5). Two grid sizes were tested to determine the coefficient of error associated with the number of sampled 'hits' (approximately 140 and 280) on the hippocampus. Starting slice and grid position were randomly varied to assure unbiased volume estimates. Raters were blind to subject identity, diagnosis, and side of the brain from which the image volumes were extracted and the order of subject presentation was randomized for each of the raters. Inter- and intra-rater intraclass correlation coefficients (ICC) were determined. Results: The data indicate excellent repeatability of fixed grid stereologic hippocampal volume measures when using an inter-slice distance of 1.5 mm and a 6.25 mm2 grid (inter-rater ICCs equals 0.86 - 0.97, intra- rater ICCs equals 0.85 - 0.97). One major advantage of the current study was the use of 3D MR data which significantly improved visualization of hippocampal boundaries by providing the ability to access simultaneous orthogonal views while counting stereological marks within the hippocampus. Conclusion: Stereological estimates of 3D volumes from 2D MR

  4. Initial study of quantitative analysis of fatty liver by 1H-MR spectroscopy imaging

    International Nuclear Information System (INIS)

    Liang Changhong; Liu Yubao; Zhang Zhonglin; Xie Shufei; Wang Qiushi

    2007-01-01

    Objective: To investigate the feasibility of 1 H-MR spectroscopy ( 1 H-MRS) imaging to quantitatively detect fatty liver. Methods: Twenty patients with fatty liver and 11 healthy volunteers underwent plain CT scan, conventional MR imaging and 1 H-MRS analysis. The blood lipid and liver function were tested on the same day as the MR examination. 1 H-MRS sequence measured the peaks of H 2 O and lipid, and the areas under the peaks. The relative contents of the lipid compound were calculated, and compared with the results of CT scan and liver function tests. Results: The CT values of the normal group and the fatty liver group were (59 ± 9) HU and (24 ± 11) HU respectively. On 1 H-MRS a protruding high H 2 O peak and a flat low lipid peak were observed in the normal group, while the protruding high H 2 O peak and a high lipid peak appeared in the fatty liver group. The values of lipid peak in the normal group and the fatty liver group were (0.05 ± 0.01) x l0 5 , (0.70 ± 0.24) x l0 5 respectively (t=4.32, P 5 , (1.85 ± 0.47) x l0 5 respectively (t=1.26, P>0.05), the areas under the lipid peak were (1.36 ± 0.73) x 10 9 , (2.35 ± 1.15) x 10 9 respectively (t=5.21, P 2 O peak were (4.33 ± 1.28) x 10 11 , (3.55 ± 0.94) x 10 11 respectively (t=2.04, P>0.05). Conclusion: 1 H-MRS imaging is feasible to quantitatively detect liver fat and is a non-invasive method for detecting early fatty liver. (authors)

  5. 30 CFR 77.215-1 - Refuse piles; identification.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Refuse piles; identification. 77.215-1 Section... COAL MINES Surface Installations § 77.215-1 Refuse piles; identification. A permanent identification marker, at least six feet high and showing the refuse pile identification number as assigned by the...

  6. Abdominopelvic 1.5-T and 3.0-T MR Imaging in Healthy Volunteers: Relationship to Formation of DNA Double-Strand Breaks.

    Science.gov (United States)

    Suntharalingam, Saravanabavaan; Mladenov, Emil; Sarabhai, Theresia; Wetter, Axel; Kraff, Oliver; Quick, Harald H; Forsting, Michael; Iliakis, Georg; Nassenstein, Kai

    2018-05-01

    Purpose To investigate the relationship between abdominopelvic magnetic resonance (MR) imaging and formation of DNA double-strand breaks (DSBs) in peripheral blood lymphocytes among a cohort of healthy volunteers. Materials and Methods Blood samples were obtained from 40 healthy volunteers (23 women and 17 men; mean age, 27.2 years [range, 21-37 years]) directly before and 5 and 30 minutes after abdominopelvic MR imaging performed at 1.5 T (n = 20) or 3.0 T (n = 20). The number of DNA DSBs in isolated blood lymphocytes was quantified after indirect immunofluorescent staining of a generally accepted DSB marker, γ-H2AX, by means of high-throughput automated microscopy. As a positive control of DSB induction, blood lymphocytes from six volunteers were irradiated in vitro with x-rays at a dose of 1 Gy (70-90 keV). Statistical analysis was performed by using a Friedman test. Results No significant alteration in the frequency of DNA DSB induction was observed after MR imaging (before imaging: 0.22 foci per cell, interquartile range [IQR] = 0.54 foci per cell; 5 minutes after MR imaging: 0.08 foci per cell, IQR = 0.39 foci per cell; 30 minutes after MR imaging: 0.09 foci per cell, IQR = 0.63 foci per cell; P = .057). In vitro radiation of lymphocytes with 1 Gy led to a significant increase in DSBs (0.22 vs 3.43 foci per cell; P = .0312). The frequency of DSBs did not differ between imaging at 1.5 T and at 3.0 T (5 minutes after MR imaging: 0.23 vs 0.06 foci per cell, respectively [P = .57]; 30 minutes after MR imaging: 0.12 vs 0.08 foci per cell [P = .76]). Conclusion Abdominopelvic MR imaging performed at 1.5 T or 3.0 T does not affect the formation of DNA DSBs in peripheral blood lymphocytes. © RSNA, 2018.

  7. MR diagnosis of temporomandibular arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Shigeaki [Kagoshima Univ. (Japan). Faculty of Dentistry

    1996-09-01

    This review described lesions of articular disk and its surrounding tissues revealed by MR examination in temporomandibular arthrosis, and problems and limits of the examination. Apparatus and imaging methods: Spin echo method was generally used and gradient echo method was alternatively used. Author`s apparatus was 1.5 tesla Signa, Advantage type, equipped with surface coil for temporomandibular joint. Imaging conditions were T1-weighted spin echo method, T2-weighted fast spin echo method, spoiled GRASS (gradient recalled acquisition in the steady state) method and GRASS method. MR findings of articular disk: MR images of normal and abnormal temporomandibular joint were presented together with computed radiographic findings. The role of dynamic imaging was described for evaluation and analysis of the joint functioning. MR findings of surrounding tissues of the disk: Dynamic MRI of the tissues was found useful to see whether the cause of pain was present inside or outside of the articular capsule. Joint effusion could not be fully imaged in T2-weighted conditions. (K.H.)

  8. MR diagnosis of temporomandibular arthrosis

    International Nuclear Information System (INIS)

    Suenaga, Shigeaki

    1996-01-01

    This review described lesions of articular disk and its surrounding tissues revealed by MR examination in temporomandibular arthrosis, and problems and limits of the examination. Apparatus and imaging methods: Spin echo method was generally used and gradient echo method was alternatively used. Author's apparatus was 1.5 tesla Signa, Advantage type, equipped with surface coil for temporomandibular joint. Imaging conditions were T1-weighted spin echo method, T2-weighted fast spin echo method, spoiled GRASS (gradient recalled acquisition in the steady state) method and GRASS method. MR findings of articular disk: MR images of normal and abnormal temporomandibular joint were presented together with computed radiographic findings. The role of dynamic imaging was described for evaluation and analysis of the joint functioning. MR findings of surrounding tissues of the disk: Dynamic MRI of the tissues was found useful to see whether the cause of pain was present inside or outside of the articular capsule. Joint effusion could not be fully imaged in T2-weighted conditions. (K.H.)

  9. Functional-anatomic evaluation of dilated uropathies in children using combined MR-nephrography and MR-urography compared to renal scintigraphy; Funktionell-anatomische Diagnostik dilatierter Uropathien bei Kindern mit kombinierter MR-Nephrographie und MR-Urographie im Vergleich zur renalen Isotopennephrographie

    Energy Technology Data Exchange (ETDEWEB)

    Reither, M. [Abt. fuer bildgebende Diagnostik am Kinderkrankenhaus Park Schoenfeld, Kassel (Germany); Tuerkay, S. [GE Medical Systems Deutschland GmbH, Solingen (Germany)

    2004-02-01

    Purpose: to evaluate MR-tomographic assessment of split renal function and degree of obstruction compared to diuretic renal scintigraphy, and pathoanatomic imaging of the urinary tract as all in one exam. Patients and methods: in a prospective study 62 children, aged 1 month to 9.5 years, mean 2.8 years, underwent diuretic renal scintigraphy and dynamic MR-nephrography at the same day except for 7 patients with a time interval of 1 day. In all patients we did T2w (water-technique) MR-urography additionally. Results: comparing spilt renal function we found a very close correlation in 54 out of 62 patients (correlation coefficient = 0.95). Due to technical failures 8 cases couldn't be calculated. Comparing degrees of obstruction there was an agreement in 57 out of 62 patients, 3 studies were gradually over-, 2 underestimated. All but one morphologic diagnoses in advance obtained by ultrasound and completed by other imaging modalities later on were confirmed MR-urographically. Though correctly imaged the functionless upper moiety in a renal duplication with ureterocele was misinterpreted at a first glance. (orig.) [German] Ziel: Es sollte geprueft werden, ob die Berechnung der seitengetrennten Nierenfunktion, die Bestimmung des Obstruktionsgrades und die pathoanatomische Darstellung des Harntraktes im Vergleich zur Diurese-Szintigraphie in einem Untersuchungsgang MR-tomographisch zuverlaessig moeglich ist. Patienten und Methode: In einer prospektiven Studie wurden bei 62 Kindern im Alter von 1 Monat bis 9,5 Jahren, Mittelwert 2,8 Jahre, ein Diurese-Szintigramm und eine dynamische MR-Nephrographie am gleichen Tag durchgefuehrt; lediglich bei 7 Patienten lag 1 Tag zwischen beiden Untersuchungen. Alle Patienten erhielten zusaetzlich eine T2w-MR-Urographie in ''Wasserbild''-Technik. Ergebnisse: Beim Vergleich der seitengetrennten Nierenfunktion fand sich eine sehr enge Korrelation bei 54 von insgesamt 62 Patienten (Korrelationskoeffizient = 0

  10. MR urography in children. Pt. 1. How we do the F0 technique

    Energy Technology Data Exchange (ETDEWEB)

    Vivier, Pierre-Hugues; Dacher, Jean-Nicolas [University Hospital of Rouen, Department of Radiology, Rouen (France); University of Rouen, LITIS Laboratory EA 4108, School of Medicine and Pharmacy, Rouen (France); Dolores, Michael [University Hospital of Rouen, Department of Radiology, Rouen (France); Taylor, Melissa [Ambroise Pare Hospital, Department of Paediatrics, Boulogne Billancourt (France); Elbaz, Frederic; Liard, Agnes [University Hospital of Rouen, Department of Pediatric Surgery, Rouen (France)

    2010-05-15

    MR urography (MRU) has been widely accepted as a substitute to intravenous urography for investigating children with a dilated urinary tract after preliminary assessment by US and voiding cystourethrography. Hydronephrosis is by far the main indication for MRU because upper tract dilatation is a frequent condition in infants and children. Recent advances in technology have allowed MR to go beyond morphology and to assess renal function parameters such as split renal function and drainage. In this article we report our routine practice of the F0 MRU technique. The main advantages of our protocol are no requirement for general anaesthesia, no bladder catheterization, use of low-dose gadolinium-based contrast agent (0.05-0.1 mmol/kg) and total acquisition time of 30 min or less. (orig.)

  11. Correction of distortion of MR pictures for MR-guided robotic sterotactic procedures

    International Nuclear Information System (INIS)

    Jonckheere, E.A.; Kwoh, Y.S.

    1988-01-01

    Ever since magnetic resonance (MR) invaded the medical imaging field, it has played an increasingly important role and is even currently being considered for stereotactic guidance of probes in the brain. While MR pictures indeed convey more clinical information than CT, the geometry of MR pictures is, unfortunately, not as accurate as the geometry of CT pictures. In other words, if a square grid phantom is scanned, then the CT picture will show a square grid, while the MR picture will rather reveal a distorted grid. This distortion is primarily due to small variations in the static magnetic field. This small distortion does not impede radiological diagnosis; however, it is a source of concern if one contemplates utilizing the MR pictures for accurate stereotactic positioning of a probe at a very precise point in the brain. Another area of application where the distortion of the MR picture should be compensated for is the superposition of CT and MR pictures so that both informations could be used for diagnosis or stereotactic purposes. This paper essentially addresses the nonlinear distortion of MR pictures and how it could be compensated for through software manipulation of the MR picture

  12. Workflow efficiency of two 1.5 T MR scanners with and without an automated user interface for head examinations.

    Science.gov (United States)

    Moenninghoff, Christoph; Umutlu, Lale; Kloeters, Christian; Ringelstein, Adrian; Ladd, Mark E; Sombetzki, Antje; Lauenstein, Thomas C; Forsting, Michael; Schlamann, Marc

    2013-06-01

    Workflow efficiency and workload of radiological technologists (RTs) were compared in head examinations performed with two 1.5 T magnetic resonance (MR) scanners equipped with or without an automated user interface called "day optimizing throughput" (Dot) workflow engine. Thirty-four patients with known intracranial pathology were examined with a 1.5 T MR scanner with Dot workflow engine (Siemens MAGNETOM Aera) and with a 1.5 T MR scanner with conventional user interface (Siemens MAGNETOM Avanto) using four standardized examination protocols. The elapsed time for all necessary work steps, which were performed by 11 RTs within the total examination time, was compared for each examination at both MR scanners. The RTs evaluated the user-friendliness of both scanners by a questionnaire. Normality of distribution was checked for all continuous variables by use of the Shapiro-Wilk test. Normally distributed variables were analyzed by Student's paired t-test, otherwise Wilcoxon signed-rank test was used to compare means. Total examination time of MR examinations performed with Dot engine was reduced from 24:53 to 20:01 minutes (P user interface (P = .001). According to this preliminary study, the Dot workflow engine is a time-saving user assistance software, which decreases the RTs' effort significantly and may help to automate neuroradiological examinations for a higher workflow efficiency. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  13. MR imaging of pleural and peritoneal effusion

    International Nuclear Information System (INIS)

    Shiono, Takahiro; Yoshikawa, Kohki; Takenaka, Eiichi; Hisamatsu, Katsuji

    1993-01-01

    The purpose of this study was to assess the efficacy of MR imaging in predicting the quality of ascites and pleural effusion. MR examinations of 20 patients with different benign or malignant diseases accompanied with ascites or pleural effusion were retrospectively studied. Results were compared with histopathological findings. On T 1 - and T 2 -weighted images, the MR intensity of the effusion depended mainly on the concentration of protein, whereas on gradient echo images, it depended mainly on the concentration of blood. MR examination was useful in non-invasively differentiating exudative or hemorrhagic effusion from serous effusion. Knowledge or inference of the quality of effusion can direct MR interpretation and may improve diagnostic accuracy. (author)

  14. Drug-induced MR urography: the effects of furosemide and intravenous saline injection on MR urography of obstructed and non-obstructed urinary tract

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Ha; Lee, Myung Jun; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    2001-10-01

    To determine the usefulness of MR urography technique for the evaluation of urinary systems in patients with obstructed urinary tract and normal volunteers with non-obstructed urinary tract after intravenous normal saline and diuretic injection. Three normal volunteers and 12 patients with urinary tract obstruction [ureteral calculi (n=8), extraurinary mass (n=1), ureteral tumor invasion (n=3)] underwent MR urography using a 1.0T scanner and a 2D non-breath-hold heavily T2-weighted fast spin-cho sequence. These acquisition were post-processed with a maximum intensity projection (MIP) algorithm. Two acquisitions were performed, the first prior to saline solution infusion following standard MR urography procedures, and the second, within 2-3 minutes of the infusion of 250 ml saline solution followed by 20 mg of Lasix administered intravenously. For this latter, drug-induced MR urography procedures were followed. In healthy volunteer (n=3) and those experiencing partial obstruction (n=4) by a urinary stone, drug-induced MR urography provided better images of the urinary tract than did standard MR urography. In those in whom a urinary stone or tumor had caused complete obstruction (n=8), standard MR urography provided good images, as did drug-induced MR urography. In patients with a partially or non-obstructed urinary tract, drug-induced MR urography provided better anatomic and functional details of the kidney and urinary tract than did standard MR urography. In those experiencing complete obstruction of the urinary tract, however, standard or drug-induced MR urography permitted very adequate evaluation of the tract, and drug-induced MR urography was unnecessary.

  15. Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-T system.

    Science.gov (United States)

    Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun; Kim, Ji Youn; Jones, Alun C; de Becker, Jan; van Cauteren, Marc

    2008-01-01

    With the development of dedicated receiver coils and increased gradient performance, 3.0-T magnetic resonance (MR) systems are gaining wider acceptance in clinical practice. The expected twofold increase in signal-to-noise ratio (SNR) compared with that of 1.5-T MR systems may help improve spatial resolution or increase temporal resolution when used with parallel acquisition techniques. Several issues must be considered when applying 3.0-T MR in the abdomen, including the alteration of the radiofrequency field and relaxation time, increase in energy deposition and susceptibility effects, and problems associated with motion artifacts. For the evaluation of liver lesions, higher SNR and greater resolution achieved with the 3.0-T system could translate into better detection of malignant lesions on T2-weighted images obtained with adjusted imaging parameters. For the evaluation of pancreatic and biliary diseases, high-resolution T2-weighted imaging using single-shot turbo spin-echo sequences is useful; improvement in SNR was noticeable on two-dimensional MR cholangiopancreatographic images. For the preoperative imaging of rectal cancer, a single-shot sequence is useful for dramatically decreasing imaging time while maintaining image quality. Substantial modification of examination protocols, with optimized imaging parameters and sequence designs along with ongoing development of hardware, could contribute to an increased role of the 3.0-T system for abdominal MR examinations.

  16. MR findings of cerebral arteriovenous malformations associated with hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro (National Defence Medical Coll., Tokorozawa, Saitama (Japan))

    1990-10-01

    This study was developed to assess the role of magnetic resonance (MR) imaging in the diagnosis of cerebral arteriovenous malformations (AVMs) associated with hemorrhage. MR images were retrospectively reviewed in 10 patients (age 8 to 60 years) who had an AVM with intracerebral or intraventricular hemorrhage. MR imaging was performed at 1.5 T obtaining T{sub 1}- and T{sub 2}-weighted spin-echo images with a slice thickness of 5 mm, and a slice interval of 0-5 mm. The AVM was detected on MR in seven patients (70%), while enhanced CT was positive in six of eight patients (75%). In six patients in whom both the AVM and intracerebral hematoma (ICH) were depicted on MR, the nidi were located not inside but adjacent to the ICH. In three patients, MR disclosed a thin subdural hematoma (SDH) which was not noted on CT. There is little difference in the detectability of AVMs by MR and enhanced CT. However, MR clearly demonstrates the anatomic relationship to associated ICH. A non-traumatic SDH with an ICH demonstrated on MR may indicate the presence of an AVM even when the AVM itself is not apparent. (author).

  17. Quantitative {sup 1}H MR spectroscopy of the brain in patients with congestive heart failure before and after cardiac transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Mee; Lee, Ho Kyu; Choi, Choong Gon; Lim, Tae Hwan [Asan Medical Center, Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of); Lee, Jung Hee [Asan Institute for Life Sciences, Seoul (Korea, Republic of)

    1999-12-01

    To evaluate the effects of cardiac transplantation on the brain in patients with congestive heart failure (CHF), using quantitative {sup 1}H MR spectroscopy ({sup 1}H-MRS). Ten patients with CHF underwent MRI and quantitative {sup 1}H-MRS before and 1-2 and 4-9 months after cardiac transplantation. MR spectra were obtained from parietal white matter (PWM) and occipital gray matter (OGM) using PROBE (PROton Brain Exam). Changes in MR signal intensity were evaluated, and the cerebral metabolic concentrations in PWM and OGM were compared. For comparative purposes, 20 normal volunteers were included. No abnormal MR signal intensity was seen in the brain before or after cardiac transplantation. Changes in cerebral metabolic concentrations were observed on {sup 1}H-MRS; concentrations of creatine (Cr) in PWM, and of N-acetylacepartate (NAA), Cr and myo-Inositol(mI) in OGM were significantly lower before transplantation. After successful transplantation, Cr levels returned to their normal range in PWM and OGM, while a slightly increase choline (Cho) level was observed in PWM. Cerebral hypoperfusion in CHF can be evaluated using {sup 1}H-MRS. MRS may play a substantial role in monitoring the effect of cardiac transplantation.

  18. Proton MR spectroscopy in solitary pulmonary nodules: a preliminary study

    International Nuclear Information System (INIS)

    Yang Chunshan; Xiao Xiangsheng; Li Huimin; Liu Shiyuan; Li Chengzhou; Li Shenjiang

    2005-01-01

    Objective: To study the characteristics and the regularities of the metabolites in solitary pulmonary nodules with proton MR spectroscopy, and to investigate the clinical value of MR spectroscopy in differentiating benign from malignant pulmonary nodules. Methods: Sixty-nine patients with solitary pulmonary nodules underwent routine MRI and single-voxel MR spectroscopy using Siemens Vision 1.5 T MR system. MR spectroscopy characteristics and parameters of the metabolites were observed and recorded. Ten pathologic specimens were examined with single-voxel MR spectroscopy. The MR spectroscopy results of the pathologic specimens were compared with those of the solitary pulmonary nodules in vivo. Results: The Cho peak (2.86 ± 1.89) of the malignant nodules was higher than that of the inflammatory (0.87 ± 0.74), tuberculous nodules (0.97 ± 1.09), and hamartoma (0.42 ± 0.53) (P 0.05). Conclusion: MR spectroscopy is reliable in evaluating pulmonary nodules in vivo. The Cho peak, Cho/Cr, and Lac peak of the malignant nodules were higher than those of inflammatory, tuberculous nodules, and hamartoma. MR spectroscopy is helpful in differentiating benign from malignant pulmonary nodules. (authors)

  19. MR imaging of acute transverse myelitis (myelopathy)

    Energy Technology Data Exchange (ETDEWEB)

    Isoda, Haruo [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Ramsey, R.G.

    1998-05-01

    The purpose of our study was to review the MR characteristics of acute transverse myelitis (ATM) retrospectively and to review the literature. The subjects were 26 patients (two males, 24 females). MR examinations were carried out using a 1.5 Tesla scanner. MR imaging in eight of 16 lesions in nine subjects with preexisting MS showed multiple areas of increased signal intensity on T{sub 2}-weighted sagittal images, and 11 lesions had no cord swelling. Twelve of 16 lesions showed heterogeneous enhancement. MR imaging in 10 of 13 lesions in 12 subjects with preexisting HTLV-1 infection, mycoplasma pneumonia infection, hepatitis B vaccinations, and uncertain etiologies revealed fusiform increased signal intensity areas on T{sub 2}-weighted sagittal images and cord swelling. Seven of 11 lesions in the patients who underwent injection of contrast medium showed heterogeneous enhancement, whereas others showed no enhancement. MR examination is recommended for the evaluation of ATM. (author)

  20. MR imaging of the female urethra

    International Nuclear Information System (INIS)

    Hricak, H.; Secaf, E.; Buckley, D.; Brown, J.J.; McAninch, J.W.; Tanagho, E.A.

    1990-01-01

    This paper evaluates the appearance of the female urethra on noncontrast and contrast-enhanced MR images and to evaluate the potential of MR imaging in the diagnosis of various urethral conditions and the staging of urethral tumors. Sixty-four patients (mean age, 54.6 years) were studied. Normal urethra was assessed in 36 patients, and urethral pathology (including urethral diverticula, inflammatory granuloma, and primary and metastatic neoplasms) in 28. MR imaging was performed on a 1.5-T magnet (General Electric Signa). T1-weighted (500/20) and T2-weighted (2,500/80) images were obtained, with a section thickness of 5 mm (20% gap), a 192 x 256 matrix, and two excitations. In 27 patients, T1-weighted images were repeated after intravenous injection of 0.1 mmol/kg of Gd-DTPA

  1. Unusual MR manifestations of neurocysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Suh, D.C. (Seoul National Univ. (Republic of Korea). Dept. of Radiology; Woolsan Medical Coll., Seoul (Republic of Korea). Dept. of Radiology); Chang, K.H.; Han, M.H.; Han, M.C.; Kim, C.W. (Seoul National Univ. (Republic of Korea). Dept. of Radiology); Lee, S.R. (Hanyang Univ., Seoul (Republic of Korea). Dept. of Radiology)

    1989-11-01

    MR and CT features of neurocysticercosis are variable and depend fundamentally on the stage in evolution of the infection, location, number and size of the worm. The authors retrospectively evaluated MR images obtained on a 2.0T superconducting unit in 22 neurocysticercosis patients and observed various MR features including some new findings. A variety of MR findings are presented with special reference to six case reports. The features include: (1) A large simple cyst containing both internal septations and a scolex; (2) suprasellar racemose cysts mimicking other cysts, (3) a fourth ventricular cyst readily depicted by aid of CSF flow-void in the sagittal plane; (4) degenerating cysts showing 'white target' appearance; (5) granulomatous lesions having a 'black target' appearance; and (6) a meningitic form showing Gd-DTPA enhancement of basal cisterns and of a subacute infarct. (orig.).

  2. Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system

    International Nuclear Information System (INIS)

    Zangos, Stephan; Mueller, C.; Mayer, F.; Naguib, N.N.; Nour-Eldin, N.E.A.; Herzog, C.; Hammerstingl, R.M.; Thalhammer, A.; Mack, M.G.; Vogl, T.J.; Eichler, K.; Hansmann, M.L.

    2009-01-01

    Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system. Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T1-weighted Flash sequences (TR/TE = 100/9; 70 ). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively. Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6%). Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies. (orig.)

  3. MR arthrography of the knee

    International Nuclear Information System (INIS)

    Kramer, J.; Engel, A. Jr.; Stiglbauer, R. Jr.; Prayer, L. Jr.; Hajek, P. Jr.; Imhof, H.

    1991-01-01

    This paper demonstrates the diagnostic value of MR arthrography in the assessment of cartilaginous lesions, including osteochondritis dissecans. One hundred thirty-two knees of 125 patients were examined with MR arthrography performed on a 1.5-T magnet with a knee resonator. T1-weighted spin-echo and T2*-weighted three-dimensional gradient-echo sequences were obtained after intraarticular administration of 40 mL of 2-mmol GD-DTPA solution. Seventy-five patients were also imaged without contrast agent. The description of the articular surface was classified into four types: I, normal cartilage surface and thickness; II, surface normal or slightly irregular; III, severe surface irregularities and cartilage defects; and IV, extensive cartilage defects, scar formation. MR findings were correlated with those of arthroscopy/arthrotomy (n = 75)

  4. MR differentiation of cystic lesions in the maxillomandibular region

    International Nuclear Information System (INIS)

    Minami, M.; Kaneda, T.; Ozawa, K.; Ozawa, M.; Itaz, Y.; Sasaki, Y.

    1991-01-01

    This paper examines the capability of MR imaging in differentiating cystic lesions in the maxillomandibular region. MR imaging of 34 patients with cystic lesions in the maxillomandibular region was performed prospectively. After T1-weighted axial imaging, T1-weighted axial and sagittal/coronal imaging with Gd-DTPA and T2-weighted axial imaging was performed. The pathologic examinations of the cases showed 9 ameloblastomas, 13 odontogenic keratocysts, and 11 other types of cysts. MR differentiation between ameloblastoma and cysts was possible in all cases but one. MR images of ameloblastoma showed solid and cystic components, multilocularity, irregularly thickened walls, mural nodules, marked Gd-DTPA enhancement of the wall, and low T1-weighted signal fluids. MR differentiation between various kinds of cysts was difficult without information from conventional radiography, except odontogenic keratocysts. MR images of 17 keratocysts showed cystic patterns, regularly thin walls monolocular cysts, weak Gd-DTPA enhancement of the walls, and inhomogeneous intensity of the contents

  5. MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-04-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined PET/magnetic resonance (MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients of the tissues and other components located in the PET field of view. MR-AC methods can be divided into 3 categories: segmentation, atlas, and PET based. This review provides a comprehensive list of the state-of-the-art MR-AC approaches and their pros and cons. The main sources of artifacts are presented. Finally, this review discusses the current status of MR-AC approaches for clinical applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Poplawski, Michael E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Charles C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Merzouk, Massine B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-01

    This report is a follow-up to CALiPER Application Summary Report 22, which investigated the photometric performance of LED MR16 lamps. The initial report found that many of the LED MR16 lamps did not perform as required by ENERGY STAR based on their equivalency claims, although they generally did provide substantial efficacy advantages compared to halogen MR16 lamps. All testing was completed using laboratory power supplies, with all but one product tested at 12 V AC. In contrast, this report examined the photoelectric performance of the same set of lamps, using commercially available transformers and dimmers as well as laboratory power supplies providing both AC and DC power.

  7. MR findings of medulloblastomas and the significance of contrast enhanced MR of brain and spine for the staging

    International Nuclear Information System (INIS)

    Chung, Jae Joon; Kim, Dong Ik; Chung, Tae Sub; Lee, Yeon Hee; Suh, Jung Ho

    1994-01-01

    The purpose of this study were to analyze the MR findings of medulloblastoma, and to evaluate the subarachnoid dissemination and the significance of contrast enhanced MR of brain and spine for tumor staging. The preoperative brain MR studies of 18 patients (9 males, 9 females; mean age, 9.4 years) with surgically proved medulloblastomas were retrospectively reviewed to characterize these neoplasms with regard to their location, size, MR signal intensity, appearance after contrast enhancement, presence of cyst and necrosis, subarachnoid dissemination, and other associated findings. In 14 patients postoperative spine MR studies were evaluated for staging and therapeutic planning. The most frequent location of medulloblastoma was the inferior vermis and the mean tumor size was 4.1 x 3.6 x 3.9 cm. On T1-weighted image, medulloblastomas generally had low to intermediate signal, predominantly hypointense relative to white matter. On T2-weighted image, medulloblastomas showed moderately high signal, hyperintense relative to white matter. Inhomogeneous contrast enhancement was demonstrated in 13 patients(72.2%) after injection of gadopentetate dimeglumine(Gadolinium). Cyst and necrosis within the tumor were visualized in 15 patients(83.3%). Subarachnoid disseminations of medulloblastomas were noted in 11 patients(61.1%), of which 6 demonstrated intracranial and 2 intraspinal dissemination. Three had both intracranial and intraspinal dissemination. In nine cases with intracranial lesions, there were intraparenchymal mass formation(7), subarachnoid nodules(5), infundibular lesions(2) and diffuse gyral enhancement(1). In five cases with intraspinal lesions, there were extramedullary intradural small nodules(3), central canal nodules(2), intradural masses(1) and fine nodular and sheet-like leptomeningeal enhancement(1). Other associated findings included intratumoral hemorrhage(11.1%), peritumoral edema(44.4%), tonsillar herniation(44.4%), hydrocephalus(88.9%) and

  8. MR and pathologic correlation of rabbit VX-2 carconoma

    International Nuclear Information System (INIS)

    Kang, H.S.; Kim, S.M.; Im, J.G.; Kim, C.W.; Han, M.C.

    1991-01-01

    This paper evaluates the reliability of MR imaging in tissue characterization and depiction of tumor boundaries. The authors performed MR-pathologic correlation using parosteally implanted VX-2 carcinoma in 17 rabbit thighs. T1-weighted, T2-weighted, and Gd-DTPA-enhanced T1-weighted axial images were obtained 10-20 days after tumor implantation. After the animals were killed, freezing, sectioning along the MR imaging planes, and histopathologic examination were done. For accurate MR-pathologic correlation, rabbits were fixed on the cardboard plate to minimize position change during the procedures. Tumor boundaries depicted on MR images were larger than those depicted on the specimen. Small tumors were surrounded by capsule-like, hypervascular (mainly lymphatics), loose connective tissue. Loose connective tissue became compact with tumor growth. This connective tissue showed high signal intensity on both T2-weighted and Gd-DTPA-enhanced T1-weighted images. Muscle atrophy with development of lymphatics around the tumor also contributed high signal intensity on MR images. Peritumoral edema and inflammatory reaction were not remarkable. Peritumoral lymphatics, rich connective tissue, and muscle atrophy exaggerated the size of experimentally induced malignant musculoskeletal tumors on MR images

  9. T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain.

    Science.gov (United States)

    Paech, Daniel; Schuenke, Patrick; Koehler, Christina; Windschuh, Johannes; Mundiyanapurath, Sibu; Bickelhaupt, Sebastian; Bonekamp, David; Bäumer, Philipp; Bachert, Peter; Ladd, Mark E; Bendszus, Martin; Wick, Wolfgang; Unterberg, Andreas; Schlemmer, Heinz-Peter; Zaiss, Moritz; Radbruch, Alexander

    2017-12-01

    Purpose To evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T. Materials and Methods This prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange-sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20% d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The median signal intensities of the assessed brain regions were compared by using the Wilcoxon rank-sum test. Results In healthy volunteers, the median signal intensity in basal ganglia gray matter (DGEρ = 4.59%) was significantly increased compared with that in white matter tissue (DGEρ = 0.65%) (P = .028). In patients, the median signal intensity in the glucose-enhanced tumor region as displayed on T1ρ-weighted DGE images (DGEρ = 2.02%) was significantly higher than that in contralateral normal-appearing white matter (DGEρ = 0.08%) (P brain glucose physiology and pathophysiologically increased glucose uptake and may have the potential to provide information about glucose metabolism in tumor tissue. © RSNA, 2017 Online supplemental material is available for this article.

  10. MR imaging of sacral and perisacral lesions

    International Nuclear Information System (INIS)

    Wetzel, L.H.; Levine, E.; Murphey, M.D.

    1987-01-01

    This exhibit demonstrates the utility of MR imaging in evaluating sacral and perisacral lesions. Thirty-two lesions were studied using a superconducting 1.0-T MR imager. Eleven primary and 13 metastatic tumors, four congenital lesions, and four arachnoid cysts were evaluated. MR did not usually enable a more specific histologic diagnosis than other imaging techniques. However, extraosseous and proximal spinal extent of tumors was well defined without use of oral or intravenous contrast material. MR imaging is an excellent noninvasive technique for evaluating most sacral and perisacral lesions and is particularly helpful when precise tumor extent must be determined for treatment planning

  11. Measurement of skeletal muscle area: Comparison of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sinelnikov, Andrey, E-mail: sinelnikovas@upmc.edu [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Qu, Chuanxing [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Fetzer, David T. [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Pelletier, Jean-Sébastien [Department of Surgery, Jewish General Hospital, McGill University, Montreal, Quebec (Canada); Dunn, Michael A. [Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Tsung, Allan [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Furlan, Alessandro [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2016-10-15

    Objective: To investigate the intra- and inter-observer agreement and correlation between CT and MR measurements of skeletal muscle area (SMA) in the abdomen. Methods: CT and MR images from twelve patients were analyzed by two blinded observers using segmentation software (MITK-3M3, Mint Medical and Slice-O-Matic, Tomovision) to quantify SMA. MR images included T1w “in-phase”, T1w “out-of-phase”, and T2w sequences. Inter- and intra-observer agreement was assessed using the intraclass correlation coefficient (ICC). Pearson correlation coefficient (r) was used to correlate measurements obtained on MR with CT. CT and MR measurements were compared with Bland-Altman plots. Results: Intra- and inter-observer agreement for SMA was high for CT and MR. For MR, the measurements on T2w images showed the highest inter-observer agreement (ICC = 0.96). CT SMA correlated closely with MR, with T2w images showing the highest correlation (r = 0.98; P < 0.01). Bland-Altman plots showed a 1.7%–3.9% bias between CT and MR measurements, lowest for T2w images. Conclusions: MR SMA measurements are reproducible and correlate closely with CT. The T2w sequence is recommended to quantify SMA on MR images.

  12. The use of MR B{sup +}{sub 1} imaging for validation of FDTD electromagnetic simulations of human anatomies

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Cornelis A T van den [Department of Radiotherapy, University Medical Center Utrecht, PO Box 85500, HP Q.00.118 3508 GA Utrecht (Netherlands); Bartels, Lambertus W [Department of Radiology, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht (Netherlands); Bergen, Bob van den [Department of Radiotherapy, University Medical Center Utrecht, PO Box 85500, HP Q.00.118 3508 GA Utrecht (Netherlands); Kroeze, Hugo [Department of Radiotherapy, University Medical Center Utrecht, PO Box 85500, HP Q.00.118 3508 GA Utrecht (Netherlands); Leeuw, Astrid A C de [Department of Radiotherapy, University Medical Center Utrecht, PO Box 85500, HP Q.00.118 3508 GA Utrecht (Netherlands); Kamer, Jeroen B van de [Department of Radiotherapy, Amsterdam Medical Center, Amsterdam, PO Box 22660, 1100 DD Amsterdam (Netherlands); Lagendijk, Jan J W [Department of Radiotherapy, University Medical Center Utrecht, PO Box 85500, HP Q.00.118 3508 GA Utrecht (Netherlands)

    2006-10-07

    In this study, MR B{sup +}{sub 1} imaging is employed to experimentally verify the validity of FDTD simulations of electromagnetic field patterns in human anatomies. Measurements and FDTD simulations of the B{sup +}{sub 1} field induced by a 3 T MR body coil in a human corpse were performed. It was found that MR B{sup +}{sub 1} imaging is a sensitive method to measure the radiofrequency (RF) magnetic field inside a human anatomy with a precision of approximately 3.5%. A good correlation was found between the B{sup +}{sub 1} measurements and FDTD simulations. The measured B{sup +}{sub 1} pattern for a human pelvis consisted of a global, diagonal modulation pattern plus local B{sup +}{sub 1} heterogeneties. It is believed that these local B{sup +}{sub 1} field variations are the result of peaks in the induced electric currents, which could not be resolved by the FDTD simulations on a 5 mm{sup 3} simulation grid. The findings from this study demonstrate that B{sup +}{sub 1} imaging is a valuable experimental technique to gain more knowledge about the dielectric interaction of RF fields with the human anatomy.

  13. Intravascular (catheter) MR imaging

    International Nuclear Information System (INIS)

    Cohen, A.M.; Hurst, G.C.; Katz, D.E.; Dverk, J.L.; Wiesen, E.J.; Czerski, L.W.; Malaya, R.; Bellon, E.M.

    1989-01-01

    Intravascular MR probes allow excellent spatial resolution and have the potential to detect arterial wall microstructure. Ultrasonic intravascular probes suggest that detailed morphologic information can assist clinical decision making. Catheter MR probes of 2--7 mm outside diameter (OD) were built of copper wire, Teflon, and parts from standard commercial catheters. The probes were connected to the surface coil receiver input of our Picker VISTA 2055HP 1.5-T imaging system. The extant (linear) body coil was used for transmit. Phantoms were constructed of coaxial glass MR tubes, filled with doped water. Watanabe rabbit aorta and human autopsy iliac artery specimens were examined within 4 hours of excision or stored by freezing. In vivo iliac arteries in dogs under general anesthesia were imaged, with percutaneous placement of the probe. Results are presented

  14. MR urography: examination techniques and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Adam, G.B.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2001-03-01

    Modern MR urography is performed on the basis of two different imaging strategies, which can be used complementarily to cover almost all aspects in the diagnosis of upper urinary tract diseases. The first technique utilizes unenhanced, heavily T2-weighted pulse sequences to obtain static-fluid images of the urinary tract. T2-weighted MR urograms have proved to be excellent in the visualization of the markedly dilated urinary tract, even if the renal excretory function is quiescent. Static-fluid MR urography is less suitable for imaging of disorders that occur in the nondilated collecting system. The second MR urography technique is analogous to the methodology of conventional intravenous pyelography and is, therefore, designated as excretory MR urography. For this purpose, a non-nephrotoxic gadolinium chelate is intravenously administered and after its renal excretion, the gadolinium-enhanced urine is visualized using fast T1-weighted gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of the contrast material inside the entire urinary tract and, secondly, to avoid high endoluminal gadolinium concentrations, which cause signal loss of the urine due to T2{sup *} effects. Gadolinium excretory MR urography allows to obtain high-quality images of both nondilated and obstructed urinary tracts in patients with normal or moderately impaired renal function. This article reviews the principles of T2- and T1-weighted MR urography in detail and informs how to use these techniques safely in potential clinical applications such as chronic urolithiasis, intrinsic and extrinsic tumor diseases, and congenital anomalies. Magnetic resonance urography performed in combination with standard MR imaging offers a potential to reduce the need for invasive retrograde pyelography. Although the economic aspect is still problematic, it is obvious that MR urography will continue to increase its role in

  15. CT and MR imaging of the kidney and adrenal glands: MR imaging of the kidney and adrenal glands

    International Nuclear Information System (INIS)

    Lee, J.K.T.

    1987-01-01

    The normal anatomy of the kidney is clearly demonstrated with MR imaging. The renal cortex can be differentiated from the renal medulla; renal vessels can also be identified. MR imaging can differentiate cystic from solid lesions. The signal intensity of a renal cell carcinoma varies and overlaps with the signal intensities of renal neoplasms of other etiologies. MR imaging is superior to CT in distinguishing vascular from nonvascular structures. It can distinguish collateral vessels from lymph nodes and can disclose tumoral thrombi. MR imaging can also aid in the differentiation of acute rejection from acute tubular necrosis in renal transplant recipients. Both normal and abnormal adrenal glands can be seen on MR imaging. A normal adrenal gland has a signal intensity higher than or equal to that of muscle but lower than that of fat. T1-weighted images offer excellent antomic resolution; T2-weighted images provide additional information about internal characteristics of adrenal neoplasms. Preliminary data indicate that MR imaging is useful in distinguishing nonfunctioning adenomas from adrenal metastases. The role of MR imaging of the kidney and adrenal gland is discussed

  16. Fibrolipomatous hamartoma: MR imaging findings

    International Nuclear Information System (INIS)

    De Maeseneer, M.; Jaovisidha, S.; Lenchik, L.; Witte, D.; Schweitzer, M.E.; Sartoris, D.J.; Resnick, D.

    1997-01-01

    Objective. To analyze the MR imaging features of fibrolipomatous hamartoma (FLH) of nerves. Design and patients. MR imaging studies from six patients (three men and three women) were retrospectively reviewed by three musculoskeletal radiologists. In four patients, a biopsy of the nerve lesion was performed. In two patients, biopsy data were unavailable and the diagnosis was based on the clinical history combined with the MR imaging findings. Results and conclusion. MR imaging demonstrated fusiform nerve enlargement that was caused by fatty proliferation and thickening of nerve bundles. Nerve bundles appeared as serpentine tubular structures, hypointense on both T1- and T2-weighted images. The degree of fatty proliferation varied among patients. In addition, significant variation in the distribution of fat along the course of the nerves was noted. In three patients, FLH followed the branching pattern of the nerves, a characteristic pathologic finding. In two patients, intramuscular fat deposition (biceps and tibialis posterior muscles) was present. MR imaging findings of FLH are typical, allowing a confident diagnosis. The variation of fatty proliferation among patients and involved nerves as well as the tendency of the abnormalities to follow the branching pattern of the nerves is well demonstrated with MR imaging. FLH may present as an isolated nerve lesion, may be associated with intramuscular fat deposition, or may occur as a feature of macrodystrophia lipomatosa (MDL). (orig.). With 5 figs., 2 tabs

  17. Soft-tissue and bone lesions examined with 1.5-T MR imaging and Gd-DOTA

    International Nuclear Information System (INIS)

    VonSchulthess, G.K.; Kuoni, W.; Wuthrich, R.; Duewell, S.; Thurnher, S.; Marincek, B.

    1988-01-01

    Fifteen patients with soft-tissue masses or bone lesions underwent 16 MR imaging examinations with gadolinium-DOTA, a new MR contrast agent. T1- and T2-weighted precontrast sequences were obtained. The contrast agent was injected in a concentration of 0.1 mmol/kg without any untoward effects. After contrast examination, one or two T1-weighted sequences were obtained. Contrast medium application improved the distinction between lesion and edema in four of seven cases, between the lesion and central necrosis in seven of eight cases, and between the lesion, and the surrounding tissues in four of 12 cases. In eight of 12 cases, additional structures within the lesion were noted after Gd-DOTA enhancement. Of particular benefit was the use of contrast media to evaluate the vascularization of the lesion (in 12 of 14 cases)

  18. How to perform and interpret cine MR enterography.

    Science.gov (United States)

    Wnorowski, Amelia M; Guglielmo, Flavius F; Mitchell, Donald G

    2015-11-01

    Magnetic resonance (MR) enterography has become a fundamental tool for small bowel evaluation. Multiphasic cine imaging is a useful component of MR enterography evaluation because it provides functional information about bowel motility. Cine MR enterography can be used to evaluate for strictures and adhesions. Bowel motility evaluation has been shown to increase pathologic lesion detection in Crohn's disease and has been incorporated into disease activity scoring systems. Currently, cine MR enterography remains underutilized. The purpose of this article is to outline how to perform and interpret cine MR enterography. The authors describe how to perform a multiphasic balanced steady state free precession sequence using different MR systems and give practical advice on how to display and interpret the cine sequence. Sample cases illustrate how the cine sequence complements standard MR enterography evaluation with T2 -weighted, contrast-enhanced T1 -weighted, and diffusion-weighted imaging. © 2015 Wiley Periodicals, Inc.

  19. Valuation of dynamic MR imaging for diagnosis of pituitary microadenomas

    International Nuclear Information System (INIS)

    Lu Wu; Zhou Shengli; Liu Yusheng

    2003-01-01

    Objective: To evaluate the use of keyhole dynamic magnetic resonance (MR) imaging in evaluation of pituitary microadenomas. Methods: Fifty-three patients with pituitary microadenomas proved by operation or clinical findings such as headache, amenorrhea, lactating, fat or acromegaly were retrospectively studied on dynamic MR, conventional contrast enhanced MR, and unenhanced MR. Then the image data were analyzed by two experienced doctors who didn't know the details and three degrees were made as follows: grade 0, no evidence of the tumor; grade I, asymmetry signals in the pituitary; and grade II, nodulated or sheets signals in the pituitary. The grading data were compared with statistical methods. Results: In dynamic MR grading system: grade 0 was revealed in 1 patient, grade I in 29 patients and grade II in 23 patients. In conventional enhanced MR: grade 0 in 26 patients, grade I in 17 patients and grade II in 10 patients. In conventional unenhanced MR: grade 0 in 39 patients, grade I in 10 patients and grade II in 4 patients. The diagnostic rate of dynamic MR, conventional enhanced MR, and unenhanced MR was 98.1%, 51.9%, and 26.4%, respectively. (P < 0.005). Dynamic MR can increase the grade of tumor compared to the other two, which is significant statistically. Conclusion: Keyhole dynamic MR can increase the diagnostic accuracy of pituitary microadenomas while decreasing the uncertainty. So dynamic MR should become a routine examination for pituitary microadenoma when suspected by clinical findings but negative in conventional MR

  20. MR-Guided PTA in Experimental Bilateral Rabbit Renal Artery Stenosis and MR Angiography Follow-Up Versus Histomorphometry

    International Nuclear Information System (INIS)

    Le Blanche, Alain-Ferdinand; Rossert, Jerome; Wassef, Michel; Levy, Bernard; Bigot, Jean-Michel; Boudghene, Frank

    2000-01-01

    Purpose: To assess in vivo 1) MR-guided percutaneous transluminal renal angioplasty (PTRA) in experimental bilateral rabbit renal artery stenosis (RAS); 2) postprocedural follow-up by gadolinium-enhanced MR angiography versus histomorphometry.Methods: Fifteen male NZW rabbits of mean weight 4.0 kg (range 3.5-4.2 kg) underwent bilateral RAS induction by combined overdilation-deendothelialization with a gadolinium-filled balloon, passively MR-guided by the artifact of a 0.014-inch guidewire. After 4 weeks the rabbits were randomized into two groups: group A (n = 8) underwent right-sided PTRA for treatment of RAS, group B (n = 7) underwent left-sided PTRA. After another 4 weeks the rabbits were killed to assess by histomorphometry recurrent stenosis and contralateral induction injury stenosis lesions. Each step was preceded by gadolinium-enhanced three-dimensional MR angiography, and the cortex-to-aorta (C/A) signal intensity ratio was calculated.Results: RAS induction was successful in all cases. Fourteen arteries developed restenosis and 13 only initial stenosis. MR-guided PTRAs were feasible in 22 arteries (73%). For a successful catheterization of the ostium (20 arteries, 66% success rate), 10-25 steps were required. Five to eight steps were required for balloon localization and inflation for each PTRA. The restenosis effect was reflected by a 16% (12%-27%) decrease in C/A values on MR angiograms (p < 0.05).Conclusion: MR guidance and MR angiography represent a feasible, less invasive alternative for performing and assessing experimental PTRA in RAS

  1. MR imaging of posttraumatic spinal ligament injury

    International Nuclear Information System (INIS)

    Pathria, M.N.; Emery, S.; Masaryk, T.J.; Wilber, R.G.; Bohlman, H.

    1988-01-01

    The accuracy of MR imaging in the detection of ligamentous injury was evaluated in 29 patients (24 male, five female) with spinal injury resulting in fractures (n=27), evidence of instability (n=11), or neurologic deficit (n=2). MR examinations were performed acutely (average, 7.5 days posttrauma) with T1- and T2-weighted imaging and were blindly evaluated. Subsequently, plain films (n=27), tomograms (n=10), and CT scans (n=22) were evaluated. Eighteen patients underwent surgery. Fourteen patients had torn ligaments as indicated by clinical and surgical findings. MR imaging demonstrated ligament damage in 13. One case imaged 40 days following trauma was not detected. No patients with intact ligaments had evidence of ligamentous damage on MR images. MR imaging demonstrated retropulsed fractures in six patients in whom the posterior longitudinal ligament was intact but displaced from the vertebra. MR imaging was more reliable than radiography and CT for detection of ligamentous injury, and T2- weighted sequences are essential in such cases

  2. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  3. Fast generation of 4D PET-MR data from real dynamic MR acquisitions

    International Nuclear Information System (INIS)

    Tsoumpas, C; Buerger, C; King, A P; Schleyer, P; Schaeffter, T; Marsden, P K; Mollet, P; Keereman, V; Vandenberghe, S; Schulz, V

    2011-01-01

    We have implemented and evaluated a framework for simulating simultaneous dynamic PET-MR data using the anatomic and dynamic information from real MR acquisitions. PET radiotracer distribution is simulated by assigning typical FDG uptake values to segmented MR images with manually inserted additional virtual lesions. PET projection data and images are simulated using analytic forward projections (including attenuation and Poisson statistics) implemented within the image reconstruction package STIR. PET image reconstructions are also performed with STIR. The simulation is validated with numerical simulation based on Monte Carlo (GATE) which uses more accurate physical modelling, but has 150x slower computation time compared to the analytic method for ten respiratory positions and is 7000x slower when performing multiple realizations. Results are validated in terms of region of interest mean values and coefficients of variation for 65 million coincidences including scattered events. Although some discrepancy is observed, agreement between the two different simulation methods is good given the statistical noise in the data. In particular, the percentage difference of the mean values is 3.1% for tissue, 17% for the lungs and 18% for a small lesion. The utility of the procedure is demonstrated by simulating realistic PET-MR datasets from multiple volunteers with different breathing patterns. The usefulness of the toolkit will be shown for performance investigations of the reconstruction, motion correction and attenuation correction algorithms for dynamic PET-MR data.

  4. Sacrococcygeal chordoma: MR imaging in 30 patients

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Mi Sook; Chung, Myung Hee [Catholic University of Korea, Holy Family Hospital, Department of Radiology, Pucheon (Korea); Lee, Gyung Kyu; Kang, Heung Sik [Seoul National University Hospital, Department of Radiology, Seoul (Korea); Kwon, Soon Tae [Chungnam University Hospital, Department of Radiology, Taejun (Korea); Park, Jin Gyoon [Chunnam University Hospital, Department of Radiology, Kwangju (Korea); Suh, Jin Suk [Yonsei University, Severans Hospital, Department of Radiology, Seoul (Korea); Cho, Gil Ho [Yeungnam University Hospital, Department of Radiology, Taegu (Korea); Lee, Sung Moon [Kaemyung University Hospital, Department of Radiology, Taeku (Korea); Resnick, Donald [VA Medical Center, Department of Radiology, San Diego, CA (United States)

    2005-02-01

    To evaluate MR imaging of sacrococcygeal chordoma. Thirty patients (age range 22-80 years) underwent MR imaging for the diagnosis and preoperative evaluation of sacrococcygeal chordomas. Eight patients had follow-up MR examination after treatment. The MR images were performed with T1- and T2-weighted imaging, and gadolinium (Gd)-enhanced imaging. The MR images were analyzed for the signal intensity, enhancing pattern, tumor size, growth pattern of the soft tissue component, and tumor extension. T1-weighted images showed low signal masses with foci of high signal intensity in 73% of cases. Tumors enhanced in a variety of patterns after the administration of Gd. Soft tissue masses extending anteriorly were seen in all cases with posterior extension in 77% of cases. The posterior masses involved the surrounding muscles and extended toward the greater sciatic notch, appearing with pseudopodia (87%). Sacroiliac joints were involved in 23% of cases. Four lesions showed intraspinal extension and involvement of the posterior spinal muscles above the level of bony involvement. In 6 patients recurrent tumors were found at or around the surgical margin of the tumor 6 months to 5 years after resection of the sacral tumor. In two of the patients, nodular metastases to the pelvic bones and femur were found 1-4 years after initial examination. In conclusion, MR imaging is useful in the diagnosis and preoperative assessment of sacrococcygeal chordoma. Characteristic findings included sacral mass with heterogeneously high signal intensity with crisscrossing septa on long-repetition-time imaging, well-encapsulated pseudopodia-like or lobulated appearance, and gluteal muscle infiltration. Follow-up MR imaging is helpful to assess for recurrent or metastatic lesions of chordomas. (orig.)

  5. MR pancreatography (MRP) for mucin-producing pancreatic tumors

    International Nuclear Information System (INIS)

    Usuki, Noriaki; Nishimoto, Masaoki; Shima, Tomoko; Hirokawa, Keiko; Tashiro, Takahiko; Saiwai, Shigeo; Miyamoto, Takeshi; Okabe, Sumihiro

    1997-01-01

    MR pancreatography was performed in 11 patients with mucin-producing pancreatic tumor (main duct type: four and branch duct type: seven) using HASTE with a body phased array coil on a 1.5-T unit. The results of MR pancreatography were compared with imaging of endoscopic retrograde pancreatography (ERP). In all cases, MR pancreatography demonstrated all dilated pancreatic ducts and cysts. ERP did not completely demonstrate dilated ducts and cysts because of mucinous materials. Conspicuity of an intraductal tumor was more excellent by ER pancreatography than MR pancreatography. Therefore MR pancreatography and ER pancreatography are complementary methods in diagnosis for mucin-producing pancreatic tumors. (author)

  6. MR imaging of medullary compression due to vertebral metastases

    International Nuclear Information System (INIS)

    Dooms, G.C.; Mathurin, P.; Maldague, B.; Cornelis, G.; Malghem, J.; Demeure, R.

    1987-01-01

    A prospective study was performed to assess the value of MR imaging for demonstrating medullary compression due to vertebral metastases in cancer patients clinically suspected of presenting with that complication. Twenty-five consecutive unselected patients were studied, and the MR imaging findings were confirmed by myelography, CT, and/or surgical and autopsy findings for each patient. The MR examinations were performed with a superconducting magnet (Philips Gyroscan S15) operating at 0.5-T. MR imaging demonstrated the metastases (single or multiple) mainly on T1- weighted images (TR = 0.45 sec and TE = 20 msec). Soft-tissue tumoral mass and/or deformity of a vertebral body secondary to metastasis, compressing the spinal cord, was equally demonstrated on T1- and heavily T2-weighted images (TR = 1.65 sec and TE = 100 msec). In the sagittal plane, MR imaging demonstrated the exact level of the compression (one or multiple levels) and its full extent. In conclusion, MR is the first imaging modality for studying cancer patients with clinically suspected medullary compression and obviates the need for more invasive procedures

  7. Hyperintense basal ganglia lesions on T1-weighted MR images in asymptomatic patients with hepatic dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Saatci, I. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey); Cila, A. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey); Dincer, F.F. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey)

    1995-12-31

    Cranial MRI findings in four patients who had hepatic dysfunction, including one with sole hepatic form of Wilson`s disease, were reported. The MR examinations revealed bilateral, symmetric hyperintensity in the globus pallidus, subthalamic nuclei and mesencephalon on T1-weighted images with no corresponding abnormality on T2-weighted sequences. The basal ganglia were normal on CT examinations in all patients. None of the patients had the clinical findings of hepatic encephalopathy. The MR findings in our patients did not correlate with the degree or duration of hepatic dysfunction. (orig.)

  8. Advanced MR diagnostic imaging in pediatric glial cell tumors: from morphological to pathophysiological evaluation

    International Nuclear Information System (INIS)

    Balev, B.; Georgiev, R.; Novakova, M.

    2013-01-01

    Full text: Introduction: The conventional MR imaging is important, and in most cases necessary imaging tool for studying the macroscopic structure, for localization and distribution of a glial brain tumor. It is an integral part of the optimal MR protocol, which further comprises a diffusion, perfusion techniques, techniques for the permeability and oxygenation assessment, as well as MR spectroscopy to the metabolism assessment. What you will learn: Glial brain tumors in children - incidence, histology, classification, diagnosis; Nature and principles of MR diffusion, perfusion, techniques for permeability and oxygenation assessment, MR spectroscopy; Contemporary techniques allowing to obtain not only MR morphological information but also to evaluate the tumor the pathophysiology: the cellular atypia, cellularity, tumor neovascularization, oxygen consumption, metabolism, status of the blood-brain barrier. This assessment determines the biological potential of the tumor, treatment options and prognosis. Discussion: The findings from conventional MR examinations, incl. administration of gadolinium contrast agents are associated with the degree of glioma and can be useful for their classification. Taking into account that from 20% to 45 % of the unenhanced supratentorial gliomas are malignant, some low-grade gliomas enhance (ganglioglioma, pilocytic astrocytoma, oligodendroglioma), 9% of malignant gliomas have no contrast enhancement, and in general, the contrast enhancement is not seen as a reliable indicator for the infiltration extent. The contemporary MR techniques improve the assessment of the pathophysiology of the tumor which is relevant to its histology and biological potential. Conclusion: Modern MR techniques besides purely diagnostic advantages (determine the extent and distribution of glioma), enable: differentiation of tumor recurrence from radiation necrosis; identification of optimal locations for biopsy or operative resection; prognosis, planning and

  9. The MR evaluation of pachygyria and associated syndromes

    International Nuclear Information System (INIS)

    Byrd, S.E.; Radkowski, M.A.; Northwestern Univ., Chicago, IL; Osborn, R.E.

    1991-01-01

    A retrospective study of 40 children with some form of pachygyria was performed at the Children's Memorial Hospital in Chicago. All children had MR brain scans. The MR findings were analyzed, and correlated with the clinical symptoms and course in all the children. 15 percent had autopsy findings. Based on the clinical, MR and autopsy findings, in conjunction with the medical literature, the following was found: (1) Pachygyria can occur as an isolated entity without an association with lissencephaly. The MR findings in these children consisted of a brain that demonstrated normal opercularization with either focal or diffuse areas of pachygyria without areas of agyria. These children live longer and have less severity of symptoms than the children with lissencephaly. (2) The MR findings in children with lissencephaly consisted of a brain that demonstrated abnormal oper-cularization with areas of total agyria or areas with agyria with pachygyria. (3) The MR findings in 25 percent of the children with poly-microgyria simulated pachygyria. The MR findings of the brain in these children consisted of a 'nubby' appearance to the outer surface of these abnormal gyri which resembled pachygyria but on histologic exam was polymicrogyria. (author). 11 refs.; 7 figs.; 1 tab

  10. MR imaging of rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo

    1992-01-01

    A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patietns, T2-wighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography. (author)

  11. Classification of bones from MR images in torso PET-MR imaging using a statistical shape model

    International Nuclear Information System (INIS)

    Reza Ay, Mohammad; Akbarzadeh, Afshin; Ahmadian, Alireza; Zaidi, Habib

    2014-01-01

    There have been exclusive features for hybrid PET/MRI systems in comparison with its PET/CT counterpart in terms of reduction of radiation exposure, improved soft-tissue contrast and truly simultaneous and multi-parametric imaging capabilities. However, quantitative imaging on PET/MR is challenged by attenuation of annihilation photons through their pathway. The correction for photon attenuation requires the availability of patient-specific attenuation map, which accounts for the spatial distribution of attenuation coefficients of biological tissues. However, the lack of information on electron density in the MR signal poses an inherent difficulty to the derivation of the attenuation map from MR images. In other words, the MR signal correlates with proton densities and tissue relaxation properties, rather than with electron density and, as such, it is not directly related to attenuation coefficients. In order to derive the attenuation map from MR images at 511 keV, various strategies have been proposed and implemented on prototype and commercial PET/MR systems. Segmentation-based methods generate an attenuation map by classification of T1-weighted or high resolution Dixon MR sequences followed by assignment of predefined attenuation coefficients to various tissue types. Intensity-based segmentation approaches fail to include bones in the attenuation map since the segmentation of bones from conventional MR sequences is a difficult task. Most MR-guided attenuation correction techniques ignore bones owing to the inherent difficulties associated with bone segmentation unless specialized MR sequences such as ultra-short echo (UTE) sequence are utilized. In this work, we introduce a new technique based on statistical shape modeling to segment bones and generate a four-class attenuation map. Our segmentation approach requires a torso bone shape model based on principle component analysis (PCA). A CT-based training set including clearly segmented bones of the torso region

  12. MR staging of endometrial carcinoma

    International Nuclear Information System (INIS)

    Innocenti, P.; Agostini, S.; Erroi, C.; Ambrogetti, D.; Cellerini, A.; Nori, J.

    1991-01-01

    Biopsy is the technique of choice for the definitive diagnosis of endometrial carcinoma. Since lymphatic tumor spread has been demonstrated to depend on the degree of myometrial involvement, the definition of the latter with imaging techniques may significantly affect both pfognosis and therapy. We investigated, by means of MR imaging at 0.5 T, 14 patients with endometrial carcinoma, to assess both tumor stage and myometrial involvement. FIGO staging system was employed, and M parameter evaluated (M0= no myometrial involvement; M1involvement confined to the inner third; M2= Involvement confined to the middle third; M3= involvement of the whole myometrium). Another parameter was the characteristic high signal of the tumor on PD and T2W images. The patients were then operated and MR information was correlated with surgical findings. Overall diagnostic accuracy of MR imaging was 85.7% in tumor staging, and 92.2% in defining M parameter. Tumor spread into adnexa and into cervical canal was poorly demonstrated by MR imaging

  13. MR imaging of epithelial cysts of the oral and maxillofacial region

    International Nuclear Information System (INIS)

    Hisatomi, Miki; Asaumi, Jun-ichi; Konouchi, Hironobu; Shigehara, Hiroshi; Yanagi, Yoshinobu; Kishi, Kanji

    2003-01-01

    The aim of the present study was to review the magnetic resonance (MR) appearance of primary epithelial cysts in order to distinguish the cysts from other possible lesions. MR images were obtained in 27 cases of epithelial cysts, including 7 odontogenic keratocysts, 3 dentigerous cysts, 1 glandular odontogenic cyst, 10 radicular cysts, 4 nasopalatine duct cysts, and 2 nasolabial cysts. In addition, contrast enhanced MR imagings were performed in 12 cases, including 3 odontogenic keratocysts, 1 dentigerous cyst, 1 glandular odontogenic cyst, and 7 radicular cysts. We obtained the following results on the basis of the above MR and contrast enhanced MR findings. (a) Odontogenic keratocysts had a predilection for intermediate-high signal intensity (SI) on T1-weighted images (WI) and heterogeneous low-high SI on T2WI. (b) Dentigerous cysts, glandular odontogenic cyst, radicular cysts and nasolabial cysts showed the same predilection with the SI, which were homogeneous intermediate SI on T1WI and homogeneous high SI on T2WI. (c) The MR images of the nasopalatine duct cysts, which showed homogeneous high SI on T1WI, were specific. (d) The Gd-T1WI would be useful in decisively differentiating odontogenic cysts, which showed rim-enhancement, from tumors consisting of solid components. In conclusion, we were able to obtain more information from the MR and contrast enhanced MR images than from conventional radiograph findings

  14. Low-Molecular-Weight Iron Chelates May Be an Alternative to Gadolinium-based Contrast Agents for T1-weighted Contrast-enhanced MR Imaging.

    Science.gov (United States)

    Boehm-Sturm, Philipp; Haeckel, Akvile; Hauptmann, Ralf; Mueller, Susanne; Kuhl, Christiane K; Schellenberger, Eyk A

    2018-02-01

    Purpose To synthesize two low-molecular-weight iron chelates and compare their T1 contrast effects with those of a commercial gadolinium-based contrast agent for their applicability in dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging. Materials and Methods The animal experiments were approved by the local ethics committee. Two previously described iron (Fe) chelates of pentetic acid (Fe-DTPA) and of trans-cyclohexane diamine tetraacetic acid (Fe-tCDTA) were synthesized with stability constants several orders of magnitude higher than those of gadolinium-based contrast agents. The T1 contrast effects of the two chelates were compared with those of gadopentetate dimeglumine in blood serum phantoms at 1.5 T, 3 T, and 7 T. For in vivo studies, a human breast cancer cell line (MDA-231) was implanted in five mice per group. The dynamic contrast effects of the chelates were compared by performing DCE MR imaging with intravenous application of Fe-DTPA or Fe-tCDTA on day 1 and DCE MR imaging in the same tumors with gadopentetate dimeglumine on day 2. Quantitative DCE maps were generated with software and were compared by means of a one-tailed Pearson correlation test. Results Relaxivities in serum (0.94 T at room temperature) of Fe-tCDTA (r1 = 2.2 mmol -1 · sec -1 , r2 = 2.5 mmol -1 · sec -1 ) and Fe-DTPA (r1 = 0.9 mmol -1 · sec -1 , r2 = 0.9 mmol -1 · sec -1 ) were approximately twofold and fivefold lower, respectively, compared with those of gadopentetate dimeglumine (r1 = 4.1 mmol -1 · sec -1 , r2 = 4.8 mmol -1 · sec -1 ). Used at moderately higher concentrations, however, iron chelates generated similar contrast effects at T1-weighted MR imaging in vitro in serum, in vivo in blood, and for DCE MR imaging of breast cancer xenografts. The volume transfer constant values for Fe-DTPA and Fe-tCDTA in the same tumors correlated well with those observed for gadopentetate dimeglumine (Fe-tCDTA Pearson R, 0.99; P = .0003; Fe-DTPA Pearson R, 0.97; P

  15. MR imaging in hemophilic arthropathy

    International Nuclear Information System (INIS)

    Baunin, C.; Railhac, J.J.; Younes, I.; Gaubert, J.; DuBoullay, C.; Dirat, G.; Robert, A.

    1990-01-01

    This paper reports on twenty children with hemophilia examined to determine if MR imaging could be used to assess hemophilic arthropathy. Twenty-eight joints were imaged (17 knees, 10 ankles, 1 elbow) with plain radiography, US, CT, and MR imaging. The results were compared with the surgical view and histologic study of the articular components when synovectomy was done. These results show the usefulness of MR imaging: fluid collections in the joint space were evaluated, and it was possible to distinguish blood from inflammatory fluid. Synovial hypertrophy was appreciated, and findings correlated well with histologic study. Anomalies of articular cartilage, joint-space narrowing, and bone lesions were demonstrated early, when plain radiography findings were still normal

  16. Retroperitoneal fibrosis: findings with MR

    International Nuclear Information System (INIS)

    Martinez Rodrigo, J.; Marti-Bonnati, L.; Diago, T.; Ferrer, M.D.; Aleixandre, A.; Morote, V.

    1993-01-01

    Retroperitoneal fibrosis (RF) is an uncommon disease characterized by the presence of a chronic inflammatory reaction, with the formation of fibrous tissue that replaces the normal retroperitoneal tissue, trapping vessels and/or ureters. We present a retrospective review of 3 cases of idiopathic RF studied by means of ultrasound, CT scan and MR imaging, and we assess the features of the MR image, as well as its capacity for characterizing the lesion. We compare the findings obtained with 3 imaging techniques, describing the utility of each one, and their advantages and disadvantages in the assessment of this pathology. In MR, idiopathic RF appears as a hypodense mass in SET1, SE-T2 and STIR sequences. (Author) 9 ref

  17. MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open high-field MRI scanner with respiratory gating

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ming; Huang, Jie; Xu, Yujun; He, Xiangmeng; Lue, Yubo; Liu, Qiang; Li, Chengli [Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong (China); Li, Lei [Qingdao Central Hospital, Department of Interventional Radiology, Qingdao, Shandong (China); Blanco Sequeiros, Roberto [Turku University Hospital, The South Western Finland Imaging Centre, Turku (Finland)

    2017-04-15

    To prospectively evaluate the feasibility, safety and accuracy of MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open MR scanner with respiratory gating. Sixty-five patients with 65 solitary pulmonary lesions underwent MR-guided percutaneous coaxial cutting needle biopsy using a 1.0-T open MR scanner with respiratory gating. Lesions were divided into two groups according to maximum lesion diameters: ≤2.0 cm (n = 31) and >2.0 cm (n = 34). The final diagnosis was established in surgery and subsequent histology. Diagnostic accuracy, sensitivity and specificity were compared between the groups using Fisher's exact test. Accuracy, sensitivity and specificity of MRI-guided percutaneous pulmonary biopsy in diagnosing malignancy were 96.9 %, 96.4 % and 100 %, respectively. Accuracy, sensitivity and specificity were 96.8 %, 96.3 % and 100 % for lesions 2.0 cm or smaller and 97.1 %, 96.4 % and 100 %, respectively, for lesions larger than 2.0 cm. There was no significant difference between the two groups (P > 0.05). Biopsy-induced complications encountered were pneumothorax in 12.3 % (8/65) and haemoptysis in 4.6 % (3/65). There were no serious complications. MRI-guided percutaneous biopsy using a 1.0-T open MR scanner with respiratory gating is an accurate and safe diagnostic technique in evaluation of pulmonary lesions. (orig.)

  18. MR imaging features of the congenital uterine anomalies

    International Nuclear Information System (INIS)

    Hamcan, S.; Akgun, V.; Battal, B.; Kocaoglu, M.

    2012-01-01

    Full text: Introduction: Congenital uterine anomalies are common and usually asymptomatic. The agenesis, malfusion or deficient resorption of the Mullerian canals during embryogenesis may lead to these anomalies. Although ultrasonography (US) is the first step imaging technique in assessment of the uterine pathologies, it can be insufficient in differentiation of them. Magnetic resonance (MR) imaging is an adequate imaging technique in depicting pelvic anatomy and different types of uterine anomalies. Objectives and tasks: In this article, we aimed to present imaging features of the uterine anomalies. Material and methods: Pelvic MR scans of the cases who were referred to our radiology department for suspicious uterine anomaly were evaluated retrospectively. Results: We determined uniconuate uterus (type II), uterus didelphys (type III), bicornuate uterus (type IV), uterine septum (type V) and arcuate uterus (type VI) anomalies according to ASRM (American Society of Reproductive Medicine) classification. Conclusion: In cases with such pathologies leading to obstruction, dysmenorrhea or palpable pelvic mass in the puberty are the main clinical presentations. In cases without obstruction, infertility or multiple abortions can be encountered in reproductive ages. The identification of the subtype of the uterine anomalies is important for the preoperative planning of the management. MR that has multiplanar imaging capability and high soft tissue resolution is a non-invasive and the most important imaging modality for the detection and classification of the uterine anomalies

  19. Texture analysis in quantitative MR imaging. Tissue characterisation of normal brain and intracranial tumours at 1.5 T

    DEFF Research Database (Denmark)

    Kjaer, L; Ring, P; Thomsen, C

    1995-01-01

    The diagnostic potential of texture analysis in quantitative tissue characterisation by MR imaging at 1.5 T was evaluated in the brain of 6 healthy volunteers and in 88 patients with intracranial tumours. Texture images were computed from calculated T1 and T2 parameter images by applying groups o...... to be successful in some cases of clinical importance. However, no discrimination between benign and malignant tumour growth was possible. Much texture information seems to be contained in MR images, which may prove useful for classification and image segmentation....

  20. [Active surveillance for prostate cancer: usefulness of endorectal MR at 1.5 Tesla with pelvic phased array coil in detecting significant tumors].

    Science.gov (United States)

    Luyckx, F; Hallouin, P; Barré, C; Aillet, G; Chauveau, P; Hétet, J-F; Bouchot, O; Rigaud, J

    2011-02-01

    To describe and assess MRI signs of significant tumor in a series of patients who all underwent radical prostatectomy and also fulfilled criteria to choose active surveillance according to French "SurAcaP" protocol. The clinical reports of 681 consecutive patients operated on for prostate cancer between 2002 and 2007 were reviewed retrospectively. All patients had endorectal MR (1.5 Tesla) with pelvic phased array coil. (1.5 T erMR PPA). Sixty-one patients (8.9%) fulfilled "SurAcaP" protocol criteria. Preoperative data (MR+core biopsy) were assessed by comparison to whole-mount step section pathology. 85.3% of the 61 patients entering SurAcaP protocol had significant tumor at pathology. (Non Organ Confined Disease (Non OCD)=8.2%, Gleason sum score>6=39.2%). A new exclusion criterion has been assessed: T3MRI±NPS>1 as a predictor tool of significant tumor. ("T3MRI±NPS>1"=Non OCD at MR±number of positive sextants involved in tumor at MR and/or Core Biopsy > to 1). Sensitivity, specificity, PPV, NPV of the criterion "T3MRI±NPS>1" in predicting significant tumor were, respectively: 77%, 33%, 86%, 20%. Adding this criterion to other criteria of the "SurAcaP" protocol could allow the exclusion of all Non OCD, and a decrease in Gleason sum Score>6 rates (20%). Endorectal MR at 1.5 Tesla with pelvic-phased array coil should be considered when selecting patients for active surveillance in the management of prostate cancer. A criterion based upon MR and core biopsy findings, called "T3MR±NSP>1" may represent an exclusion citeria due to its ability to predict significant tumor. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  1. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  2. Early evaluation of irradiated parotid glands with intravoxel incoherent motion MR imaging: correlation with dynamic contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Zhou, Nan; Chu, Chen; Dou, Xin; Li, Ming; Liu, Song; Zhu, Lijing; Liu, Baorui; Guo, Tingting; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng; Liu, Tian

    2016-01-01

    Radiation-induced parotid damage is one of the most common complications in patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy (RT). Intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging has been reported for evaluating irradiated parotid damage. However, the changes of IVIM perfusion-related parameters in irradiated parotid glands have not been confirmed by conventional perfusion measurements obtained from dynamic contrast-enhanced (DCE) MR imaging. The purposes of this study were to monitor radiation-induced parotid damage using IVIM and DCE MR imaging and to investigate the correlations between changes of these MR parameters. Eighteen NPC patients underwent bilateral parotid T1-weighted, IVIM and DCE MR imaging pre-RT (2 weeks before RT) and post-RT (4 weeks after RT). Parotid volume; IVIM MR parameters, including apparent diffusion coefficient (ADC), pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f); and DCE MR parameters, including maximum relative enhancement (MRE), time to peak (TTP), Wash in Rate, and the degree of xerostomia were recorded. Correlations of parotid MR parameters with mean radiation dose, atrophy rate and xerostomia degree, as well as the relationships between IVIM and DCE MR parameters, were investigated. From pre-RT to post-RT, all of the IVIM and DCE MR parameters increased significantly (p < 0.001 for ADC, D, f, MRE, Wash in Rate; p = 0.024 for D*; p = 0.037 for TTP). Change rates of ADC, f and MRE were negatively correlated with atrophy rate significantly (all p < 0.05). Significant correlations were observed between the change rates of D* and MRE (r = 0.371, p = 0.026) and between the change rates of D* and TTP (r = 0.396, p = 0.017). The intra- and interobserver reproducibility of IVIM and DCE MR parameters was good to excellent (intraclass correlation coefficient, 0.633–0.983). Early radiation-induced changes of parotid glands could be evaluated by IVIM and

  3. Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction.

    Science.gov (United States)

    Attenberger, Ulrike; Catana, Ciprian; Chandarana, Hersh; Catalano, Onofrio A; Friedman, Kent; Schonberg, Stefan A; Thrall, James; Salvatore, Marco; Rosen, Bruce R; Guimaraes, Alexander R

    2015-08-01

    Simultaneous data collection for positron emission tomography and magnetic resonance imaging (PET/MR) is now a reality. While the full benefits of concurrently acquiring PET and MR data and the potential added clinical value are still being evaluated, initial studies have identified several important potential pitfalls in the interpretation of fluorodeoxyglucose (FDG) PET/MRI in oncologic whole-body imaging, the majority of which being related to the errors in the attenuation maps created from the MR data. The purpose of this article was to present such pitfalls and artifacts using case examples, describe their etiology, and discuss strategies to overcome them. Using a case-based approach, we will illustrate artifacts related to (1) Inaccurate bone tissue segmentation; (2) Inaccurate air cavities segmentation; (3) Motion-induced misregistration; (4) RF coils in the PET field of view; (5) B0 field inhomogeneity; (6) B1 field inhomogeneity; (7) Metallic implants; (8) MR contrast agents.

  4. Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist.

    Science.gov (United States)

    Sutherland, John K; Nozaki, Taiki; Kaneko, Yasuhito; J Yu, Hon; Rafijah, Gregory; Hitt, David; Yoshioka, Hiroshi

    2016-01-16

    Our study was performed to evaluate the image quality of 3 T MR wrist arthrograms with attention to ulnar wrist structures, comparing image quality of isotropic 3D proton density fat suppressed turbo spin echo (PDFS TSE) sequence versus standard 2D 3 T sequences as well as comparison with 1.5 T MR arthrograms. Eleven consecutive 3 T MR wrist arthrograms were performed and the following sequences evaluated: 3D isotropic PDFS, repetition time/echo time (TR/TE) 1400/28.3 ms, voxel size 0.35x0.35x0.35 mm, acquisition time 5 min; 2D coronal sequences with slice thickness 2 mm: T1 fat suppressed turbo spin echo (T1FS TSE) (TR/TE 600/20 ms); proton density (PD) TSE (TR/TE 3499/27 ms). A 1.5 T group of 18 studies with standard sequences were evaluated for comparison. All MR imaging followed fluoroscopically guided intra-articular injection of dilute gadolinium contrast. Qualitative assessment related to delineation of anatomic structures between 1.5 T and 3 T MR arthrograms was carried out using Mann-Whitney test and the differences in delineation of anatomic structures among each sequence in 3 T group were analyzed with Wilcoxon signed-rank test. Quantitative assessment of mean relative signal intensity (SI) and relative contrast measurements was performed using Wilcoxon signed-rank test. Mean qualitative scores for 3 T sequences were significantly higher than 1.5 T (p < 0.01), with isotropic 3D PDFS sequence having highest mean qualitative scores (p < 0.05). Quantitative analysis demonstrated no significant difference in relative signal intensity among the 3 T sequences. Significant differences were found in relative contrast between fluid-bone and fluid-fat comparing 3D and 2D PDFS (p < 0.01). 3D isotropic PDFS sequence showed promise in both qualitative and quantitative assessment, suggesting this may be useful for MR wrist arthrograms at 3 T. Primary reasons for diagnostic potential include the ability to make reformations in any

  5. MR findings of spondylolysis

    International Nuclear Information System (INIS)

    Ojiri, Hiroya; Fukuda, Kunihiko; Hashimoto, Toru; Doi, Michiko; Irie, Takeo; Tatsuno, Satoshi; Tada, Shinpei; Toyoda, Keiko.

    1994-01-01

    We reviewed MR images of 50 patients with spondylolisthesis to disclose MR findings of spondylolysis. In almost half of our series, spondylolysis was detected as a low signal intensity band traversing in the pairs interarticularis on both T1 and T2 weighted images. Sagittal images was superior to axial image in detection of the low signal intensity band. In some patients, a focal high signal intensity accompanying the low signal intensity band was considered to be fluid collection within pseudoarthrosis due to spondylolysis on T2-weighted image. (author)

  6. MR findings of spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Ojiri, Hiroya; Fukuda, Kunihiko; Hashimoto, Toru; Doi, Michiko; Irie, Takeo; Tatsuno, Satoshi; Tada, Shinpei (Jikei Univ., Tokyo (Japan). School of Medicine); Toyoda, Keiko

    1994-08-01

    We reviewed MR images of 50 patients with spondylolisthesis to disclose MR findings of spondylolysis. In almost half of our series, spondylolysis was detected as a low signal intensity band traversing in the pairs interarticularis on both T1 and T2 weighted images. Sagittal images was superior to axial image in detection of the low signal intensity band. In some patients, a focal high signal intensity accompanying the low signal intensity band was considered to be fluid collection within pseudoarthrosis due to spondylolysis on T2-weighted image. (author).

  7. Coronal MR imaging of the normal 3rd, 4th, and 5th lumbar and 1st sacral nerve roots

    International Nuclear Information System (INIS)

    Hald, J.K.; Nakstad, P.H.; Hauglum, B.E.

    1991-01-01

    Seven healthy volunteers underwent coronal MR imaging at 1.5 tesla of the normal 3rd, 4th, and 5th lumbar, and 1st sacral nerve roots. Coronal slices, 3-mm-thick with a 0.3-mm gap between the slices were obtained (TR/TE 600/22) through the lumbar spinal canal. All the nerve roots were visible on at least one image. One can routinely expect to demonstrate the 3rd, 4th, and 5th lumbar, and 1st sacral nerve roots on T1-weighted, 3-mm-thick coronal MR scans. We found no correlation between the degree of lumbar lordosis and the lengths of the visible nerve roots. Five patients with one of the following spinal problems: anomaly, tumor, disk herniation, and failed back surgery syndrome were examined according to our protocol. In all these cases coronal MR imaging gave the correct diagnosis. (orig.)

  8. Coronal MR imaging of the normal 3rd, 4th, and 5th lumbar and 1st sacral nerve roots

    Energy Technology Data Exchange (ETDEWEB)

    Hald, J K; Nakstad, P H; Hauglum, B E [National Hospital, Oslo (Norway). Dept. of Radiology

    1991-05-01

    Seven healthy volunteers underwent coronal MR imaging at 1.5 tesla of the normal 3rd, 4th, and 5th lumbar, and 1st sacral nerve roots. Coronal slices, 3-mm-thick with a 0.3-mm gap between the slices were obtained (TR/TE 600/22) through the lumbar spinal canal. All the nerve roots were visible on at least one image. One can routinely expect to demonstrate the 3rd, 4th, and 5th lumbar, and 1st sacral nerve roots on T1-weighted, 3-mm-thick coronal MR scans. We found no correlation between the degree of lumbar lordosis and the lengths of the visible nerve roots. Five patients with one of the following spinal problems: anomaly, tumor, disk herniation, and failed back surgery syndrome were examined according to our protocol. In all these cases coronal MR imaging gave the correct diagnosis. (orig.).

  9. Interventional MR: vascular applications.

    Science.gov (United States)

    Smits, H F; Bos, C; van der Weide, R; Bakker, C J

    1999-01-01

    Three strategies for visualisation of MR-dedicated guidewires and catheters have been proposed, namely active tracking, the technique of locally induced field inhomogeneity and passive susceptibility-based tracking. In this article the pros and cons of these techniques are discussed, including the development of MR-dedicated guidewires and catheters, scan techniques, post-processing tools, and display facilities for MR tracking. Finally, some of the results obtained with MR tracking are discussed.

  10. Dynamic MR imaging in Tolosa-Hunt syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Haque, Tabassum Laz; Miki, Yukio; Kashii, Satoshi; Yamamoto, Akira; Kanagaki, Mitsunori; Takahashi, Takahiro; Fushimi, Yasutaka; Asato, Reinin; Murase, Nagako; Shibasaki, Hiroshi; Konishi, Junji

    2004-09-01

    Objective: To evaluate the cavernous sinuses with dynamic magnetic resonance (MR) imaging in patients with Tolosa-Hunt syndrome (THS). Methods: The sellar and parasellar regions of five patients with THS and 12 control subjects were examined with dynamic MR (1.5 T) imaging in the coronal plane. Dynamic images were obtained with spin-echo (SE) sequences in three patients, and with fast spin-echo (FSE) sequences in two patients and control subjects. Conventional MR images of the cranium including sellar and parasellar regions were also obtained on T1-weighted pre- and post-contrast SE, and T2-weighted FSE sequences in the coronal plane. Results: MR images revealed affected cavernous sinus with bulged convex lateral wall in three patients and concave lateral wall in two patients. In all control subjects, cavernous sinuses were observed with concave lateral wall. The signal intensity on T1- and T2-weighted images and contrast enhancement on post-contrast images of the affected cavernous sinuses in patients were similar to those of the unaffected cavernous sinuses in patients and control subjects. The dynamic images in all patients disclosed small areas adjacent to the cranial nerve filling-defects within the enhanced venous spaces of the affected cavernous sinus, which showed slow and gradual enhancement from the early to the late dynamic images. No such gradually enhancing area was observed in control subjects except one. The follow-up dynamic MR images after corticosteroid therapy revealed complete resolution of the gradually enhancing areas in the previously affected cavernous sinus. Conclusion: Dynamic MR imaging may facilitate the diagnosis of THS.

  11. Dynamic MR imaging in Tolosa-Hunt syndrome

    International Nuclear Information System (INIS)

    Haque, Tabassum Laz; Miki, Yukio; Kashii, Satoshi; Yamamoto, Akira; Kanagaki, Mitsunori; Takahashi, Takahiro; Fushimi, Yasutaka; Asato, Reinin; Murase, Nagako; Shibasaki, Hiroshi; Konishi, Junji

    2004-01-01

    Objective: To evaluate the cavernous sinuses with dynamic magnetic resonance (MR) imaging in patients with Tolosa-Hunt syndrome (THS). Methods: The sellar and parasellar regions of five patients with THS and 12 control subjects were examined with dynamic MR (1.5 T) imaging in the coronal plane. Dynamic images were obtained with spin-echo (SE) sequences in three patients, and with fast spin-echo (FSE) sequences in two patients and control subjects. Conventional MR images of the cranium including sellar and parasellar regions were also obtained on T1-weighted pre- and post-contrast SE, and T2-weighted FSE sequences in the coronal plane. Results: MR images revealed affected cavernous sinus with bulged convex lateral wall in three patients and concave lateral wall in two patients. In all control subjects, cavernous sinuses were observed with concave lateral wall. The signal intensity on T1- and T2-weighted images and contrast enhancement on post-contrast images of the affected cavernous sinuses in patients were similar to those of the unaffected cavernous sinuses in patients and control subjects. The dynamic images in all patients disclosed small areas adjacent to the cranial nerve filling-defects within the enhanced venous spaces of the affected cavernous sinus, which showed slow and gradual enhancement from the early to the late dynamic images. No such gradually enhancing area was observed in control subjects except one. The follow-up dynamic MR images after corticosteroid therapy revealed complete resolution of the gradually enhancing areas in the previously affected cavernous sinus. Conclusion: Dynamic MR imaging may facilitate the diagnosis of THS

  12. from left to right : Mr Michel Della Negra (Last spokeperson of CMS), Prof. Tejinder ("Jim") Virdee (actual spokeperson of CMS), Mr Robert Aymar (CERN Director General) and Mr Sigurd Lettow (Chief Financial Officer of CERN) assist to the Lowering of the final element (YE-1) of the Compact Muon Solenoid (CMS) detector into its underground experimental cavern.

    CERN Multimedia

    Maximilien Brice

    2008-01-01

    from left to right : Mr Michel Della Negra (Last spokeperson of CMS), Prof. Tejinder ("Jim") Virdee (actual spokeperson of CMS), Mr Robert Aymar (CERN Director General) and Mr Sigurd Lettow (Chief Financial Officer of CERN) assist to the Lowering of the final element (YE-1) of the Compact Muon Solenoid (CMS) detector into its underground experimental cavern.

  13. MR evaluation of brachial plexus injuries

    International Nuclear Information System (INIS)

    Gupta, R.K.; Jain, R.K.; Mehta, V.S.; Banerji, A.K.

    1989-01-01

    Ten cases of brachial plexus injury were subjected to magnetic resonance (MR) to demonstrate the roots, trunks, divisions or cord abnormalities. Both normal and abnormal brachial plexuses were imaged in sagittal, axial, coronal and axial oblique planes. Myelography, using water soluble contrast agents, was performed in seven cases. MR demonstrated one traumatic meningocele, one extradural cerebrospinal fluid (CSF) collection, trunk and/or root neuromas in four, focal root fibrosis in two and diffuse fibrosis in the remaining two cases. Results of MR were confirmed at surgery in four cases with neuromas, while myelography was normal in two and was not carried out in the remaining two. In two cases, where MR demonstrated diffuse fibrosis of the brachial plexus, myelography showed C7 and T1 traumatic meningocele in one and was normal in the other. Both these patients showed excellent clinical and electrophysiological correlation with MR findings and in one of them surgical confirmation was also obtained. In the other two cases with focal nerve root fibrosis, myelography was normal in one and showed a traumatic meningocele in another. Operative findings in these cases confirmed focal root fibrosis but no root avulsion was observed although seen on one myelogram. Focal fibrosis, however, was noted at operation in more roots than was observed with MR. Initial experience suggests that MR may be the diagnostic procedure of choice for complete evaluation of brachial plexus injuries. (orig.)

  14. In Situ Analysis of a Silver Nanoparticle-Precipitating Shewanella Biofilm by Surface Enhanced Confocal Raman Microscopy.

    Directory of Open Access Journals (Sweden)

    Gal Schkolnik

    Full Text Available Shewanella oneidensis MR-1 is an electroactive bacterium, capable of reducing extracellular insoluble electron acceptors, making it important for both nutrient cycling in nature and microbial electrochemical technologies, such as microbial fuel cells and microbial electrosynthesis. When allowed to anaerobically colonize an Ag/AgCl solid interface, S. oneidensis has precipitated silver nanoparticles (AgNp, thus providing the means for a surface enhanced confocal Raman microscopy (SECRaM investigation of its biofilm. The result is the in-situ chemical mapping of the biofilm as it developed over time, where the distribution of cytochromes, reduced and oxidized flavins, polysaccharides and phosphate in the undisturbed biofilm is monitored. Utilizing AgNp bio-produced by the bacteria colonizing the Ag/AgCl interface, we could perform SECRaM while avoiding the use of a patterned or roughened support or the introduction of noble metal salts and reducing agents. This new method will allow a spatially and temporally resolved chemical investigation not only of Shewanella biofilms at an insoluble electron acceptor, but also of other noble metal nanoparticle-precipitating bacteria in laboratory cultures or in complex microbial communities in their natural habitats.

  15. Pancreatic adenocarcinoma: combination of MR imaging, MR angiography and MR cholangiopancreatography for the diagnosis and assessment of resectability

    International Nuclear Information System (INIS)

    Catalano, C.; Pavone, P.; Laghi, A.; Panebianco, V.; Scipioni, A.; Fanelli, F.; Brillo, R.; Passariello, R.

    1998-01-01

    The purpose of this study was to determine the possibility of integrating MR cholangiopancreatography (MRCP) and MR angiography (MRA) to conventional MR images in the diagnosis and assessment of resectability of pancreatic adenocarcinoma. Twenty-three patients with pancreatic adenocarcinoma were prospectively examined with MR. Conventional MR images were acquired in all patients. Three-dimensional MRCP and MRA images were acquired in all patients with suspected biliary and vascular involvement. Acquisition time was less than 45 min in all cases. Images were independently evaluated by two radiologists, with final reading decided by consensus among readers. Diagnosis was confirmed with surgery in 16 patients and with percutaneous biopsy in 7. Concordance among readers was high with a kappa value of 0.83. Pancreatic adenocarcinoma was observed in all patients. Correct assessment of unresectability due to vascular involvement was found in 22 of 23 patients. Biliary obstruction was evident in 13 patients, involving the biliary and pancreatic ducts in 9 and the biliary ducts only in 4. Technical advances permit extensive use of MRI in the evaluation of abdominal pathologies. The combination of MR imaging, MRCP, and MRA can provide sufficient information for the diagnosis and assessment of resectability of pancreatic adenocarcinoma, which otherwise would require three different exams. (orig.)

  16. MR anatomy of the joints: an MR-cadaveric correlative study: part I. wrist

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Heung Sik [Seoul National University College of Medicine, Seoul (Korea, Republic of); Donald Resnick [University of California, San Diego (United States)

    1991-07-15

    To acquire the anatomic information necessary for correct interpretation of MR images of the wrist, transverse, coronal, and sagittal MR images of 3 fresh cadaveric wrists were obtained and, subsequently, sectioned along the MR imaging planes. For the precise correlation of anatomic features depicted with MR and with specimen section, cadaveric wrists were fixed in a rectangular cardboard box using paraffin and frozen after MR imaging. High contrast and spatial resolution enabled delineation of small structures including tendons, nerves, vessels, and ligaments, as well as osseous structures. Transverse images provided the best delineation of the carpal tunnel, tendons, nerves, and vessels. Coronal images permitted optimal visualization of triangular fibrocartilage and lunotriquetral and scapholunate ligaments. We conclude that MR imaging accurately and reliably displays the anatomy of the wrist.

  17. PET/MR in oncology: an introduction with focus on MR and future perspectives for hybrid imaging

    Science.gov (United States)

    Balyasnikova, Svetlana; Löfgren, Johan; de Nijs, Robin; Zamogilnaya, Yanna; Højgaard, Liselotte; Fischer, Barbara M

    2012-01-01

    After more than 20 years of research, a fully integrated PET/MR scanner was launched in 2010 enabling simultaneous acquisition of PET and MR imaging. Currently, no clinical indication for combined PET/MR has been established, however the expectations are high. In this paper we will discuss some of the challenges inherent in this new technology, but focus on potential applications for simultaneous PET/MR in the field of oncology. Methods and tracers for use with the PET technology will be familiar to most readers of this journal; thus this paper aims to provide a short and basic introduction to a number of different MRI techniques, such as DWI-MR (diffusion weighted imaging MR), DCE-MR (dynamic contrast enhanced MR), MRS (MR spectroscopy) and MR for attenuation correction of PET. All MR techniques presented in this paper have shown promising results in the treatment of patients with solid tumors and could be applied together with PET increasing the amount of information about the tissues of interest. The potential clinical benefit of applying PET/MR in staging, radiotherapy planning and treatment evaluation in oncology, as well as the research perspectives for the use of PET/MR in the development of new tracers and drugs will be discussed. PMID:23145362

  18. Brain water mapping with MR imaging

    International Nuclear Information System (INIS)

    Laine, F.J.; Fatouros, P.P.; Kraft, K.A.

    1990-01-01

    This paper reports on a recently developed MR imaging technique to determine the spatial distribution of brain water to healthy volunteers. A noninvasive MR imaging technique to obtain absolute measurements of brain water has been developed and validated with phantom and animal studies. Patient confirmation was obtained from independent gravimetric measurements of brain tissue samples harvested by biopsy. This approach entails the production of accurate T1 maps from multiple inversion recovery images of a selected anatomic section and their subsequent conversion into an absolute water image by means of a previously determined calibration curve. Twenty healthy volunteers were studied and their water distribution was determined in a standard section. The following brain water values means and SD grams of water per gram of tissue) were obtained for selected brain regions; white matter, 68.9% ± 1.0; corpus callosum, 67.4% ± 1.1; thalamus, 75.3% ± 1.4; and caudate nucleus, 80.3% ± 1.4. MR imaging water mapping is a valid means of determining water content in a variety of brain tissues

  19. Questionnaire responses concerning safety issues in MR examination

    International Nuclear Information System (INIS)

    Yamaguchi-Sekino, Sachiko; Nakai, Toshiharu; Muranaka, Hiroyuki

    2011-01-01

    Recently, the rising numbers of medical implants and scanners with higher static magnetic field have increased safety concerns for magnetic resonance (MR) examination. To determine future safety focus, we distributed anonymous questionnaires to 3250 members of the Japanese Society for Magnetic Resonance in Medicine (JSMRM) and received 978 responses. Safety issues on the questionnaire concentrated on the handling of patients with implants (Q7-18, appendix), acoustic trauma due to scanning (Q19-21, appendix), and MR compatibility within the scanner room (Q22-25, appendix). Ninety-three percent of respondents indicated they had encountered cases with implants or medical materials of unknown MR compatibility; 21.7% reported heating problems and 15.0%, nerve stimulation problems, in patients with implants during MR examination. Although 88.7% of respondents recognized the term ''MR compatibility'', 68.2% indicated limited detailed understanding of the term. Eleven percent had had cases with suspected acoustic injury from MR scanner noise. Scanner noise levels were not clarified in any way in 37.4% cases, but 69.5% applied ear protection to patients. Labeling of ''MR compatibility'' of equipment brought into the MR scanner room was reported by 71.9%. More than 50% experienced MR compatibility issues related to equipment brought into the MR scanner room. With regard to safety issues on metallic objects which are implanted in MR workers, 88.1% indicated they would continue current operations even the implant is inside the body. Respondents identified lectures and seminars by professional societies, safety training by manufacturers, and information from the Internet and literature as the 3 main sources for up-dating safety information for MR examination. (author)

  20. High-field MR imaging of spinal cord vascular lesions

    International Nuclear Information System (INIS)

    Blas, C.; Halimi, P.; Sigal, R.; Doyon, D.; Hurth, M.

    1986-01-01

    MR imaging (1.5T) was performed in 20 patients with spinal cord vascular malformations and hemangioblastomas. MR imaging findings were correlated with data obtained by other imaging modalities (myelography, CT and selective angiography). A diagnosis of vascular legions was suspected or established in 15 patients. Seven had a history of embolization or surgery prior to MR imaging. Six of seven hemangioblastomas were detected on MR imaging. The diagnosis was incorrect in one case because of the small size of the hemangioblastoma nodule, although the cystic part of the lesion was correctly identified. In three cases, the diagnosis was made first on MR imaging and then confirmed on angiography and surgery. Eleven vascular malformations were studied. Malformative thrombosis was found in four of the 11, as suggested by high-intensity signals on T1- and T2-weighted images

  1. Content-based image retrieval using spatial layout information in brain tumor T1-weighted contrast-enhanced MR images.

    Science.gov (United States)

    Huang, Meiyan; Yang, Wei; Wu, Yao; Jiang, Jun; Gao, Yang; Chen, Yang; Feng, Qianjin; Chen, Wufan; Lu, Zhentai

    2014-01-01

    This study aims to develop content-based image retrieval (CBIR) system for the retrieval of T1-weighted contrast-enhanced MR (CE-MR) images of brain tumors. When a tumor region is fed to the CBIR system as a query, the system attempts to retrieve tumors of the same pathological category. The bag-of-visual-words (BoVW) model with partition learning is incorporated into the system to extract informative features for representing the image contents. Furthermore, a distance metric learning algorithm called the Rank Error-based Metric Learning (REML) is proposed to reduce the semantic gap between low-level visual features and high-level semantic concepts. The effectiveness of the proposed method is evaluated on a brain T1-weighted CE-MR dataset with three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor). Using the BoVW model with partition learning, the mean average precision (mAP) of retrieval increases beyond 4.6% with the learned distance metrics compared with the spatial pyramid BoVW method. The distance metric learned by REML significantly outperforms three other existing distance metric learning methods in terms of mAP. The mAP of the CBIR system is as high as 91.8% using the proposed method, and the precision can reach 93.1% when the top 10 images are returned by the system. These preliminary results demonstrate that the proposed method is effective and feasible for the retrieval of brain tumors in T1-weighted CE-MR Images.

  2. Content-based image retrieval using spatial layout information in brain tumor T1-weighted contrast-enhanced MR images.

    Directory of Open Access Journals (Sweden)

    Meiyan Huang

    Full Text Available This study aims to develop content-based image retrieval (CBIR system for the retrieval of T1-weighted contrast-enhanced MR (CE-MR images of brain tumors. When a tumor region is fed to the CBIR system as a query, the system attempts to retrieve tumors of the same pathological category. The bag-of-visual-words (BoVW model with partition learning is incorporated into the system to extract informative features for representing the image contents. Furthermore, a distance metric learning algorithm called the Rank Error-based Metric Learning (REML is proposed to reduce the semantic gap between low-level visual features and high-level semantic concepts. The effectiveness of the proposed method is evaluated on a brain T1-weighted CE-MR dataset with three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor. Using the BoVW model with partition learning, the mean average precision (mAP of retrieval increases beyond 4.6% with the learned distance metrics compared with the spatial pyramid BoVW method. The distance metric learned by REML significantly outperforms three other existing distance metric learning methods in terms of mAP. The mAP of the CBIR system is as high as 91.8% using the proposed method, and the precision can reach 93.1% when the top 10 images are returned by the system. These preliminary results demonstrate that the proposed method is effective and feasible for the retrieval of brain tumors in T1-weighted CE-MR Images.

  3. MR and MR arthrography to identify degenerative and posttraumatic diseases in the shoulder joint

    International Nuclear Information System (INIS)

    Lee, Shi-Uk; Lang, Philipp

    2000-01-01

    MR imaging provides a comprehensive evaluation of a wide spectrum of both intraarticular and extraarticular pathology of the shoulder. MR imaging enables the detection or exclusion of degenerative and posttraumatic diseases of the shoulder with a reasonable accuracy. MR arthrography is useful in the visualization of subtle anatomic details and further improves the differentiation. In this article, findings of MR imaging and MR arthrography of degenerative and posttraumatic shoulder diseases (impingement syndrome, rotator cuff tears, and glenohumeral instability) has been reviewed

  4. Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique.

    Science.gov (United States)

    Kirchgesner, T; Perlepe, V; Michoux, N; Larbi, A; Vande Berg, B

    2018-01-01

    To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging. Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (PCHESS sequence and the 3D FSE T1-weighted CHESS sequence (PCHESS sequence (PCHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (PCHESS technique at 3D T1-weighted MR imaging of the hands. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  5. MR evaluation of CSF fistulae

    International Nuclear Information System (INIS)

    Gupta, V.; Goyal, M.; Mishra, N.; Gaikwad, S.; Sharma, A.

    1997-01-01

    Purpose: To evaluate the role of MR imaging in the localisation of cerebrospinal fluid (CSF) fistulae. Material and Methods: A total of 36 consecutive unselected patients with either clincally proven CSF leakage (n=26) or suspected CSF fistula (n=10) were prospectively evaluated by MR. All MR examinations included fast spin-echo T2-weighted images in the 3 orthogonal planes. Thin-section CT was performed following equivocal or negative MR examination. MR and CT findings were correlated with surgical results in 33 patients. Results: CSF fistula was visualised as a dural-bone defect with hyperintense fluid signal continuous with that in the basal cisterns on T2-weighted images. MR was positive in 26 cases, in 24 of which the fistula was confirmed surgically. In 2 patients the CSF leakage was directly demonstrated on MR. MR sensitivity of 80% compared favourably with the reported 46-81% of CT cisternography (CTC). No significant difference in MR sensitivity in detecting CSF fistula was found between active and inactive leaks. (orig.)

  6. Towards Implementing an MR-based PET Attenuation Correction Method for Neurological Studies on the MR-PET Brain Prototype

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J.; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A. Gregory

    2013-01-01

    A number of factors have to be considered for implementing an accurate attenuation correction (AC) in a combined MR-PET scanner. In this work, some of these challenges were investigated and an AC method based entirely on the MR data obtained with a single dedicated sequence was developed and used for neurological studies performed with the MR-PET human brain scanner prototype. Methods The focus was on the bone/air segmentation problem, the bone linear attenuation coefficient selection and the RF coil positioning. The impact of these factors on the PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultra-short echo time (DUTE) MR sequence was proposed for head imaging. Simultaneous MR-PET data were acquired and the PET images reconstructed using the proposed MR-DUTE-based AC method were compared with the PET images reconstructed using a CT-based AC. Results Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm−1 to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. Based on these results, the segmented CT AC method was established as the “silver standard” for the segmented MR-based AC method. Particular to an integrated MR-PET scanner, ignoring the RF coil attenuation can cause large underestimations (i.e. up to 50%) in the reconstructed images. Furthermore, the coil location in the PET field of view has to be accurately known. Good quality bone/air segmentation can be performed using the DUTE data. The PET images obtained using the MR-DUTE- and CT-based AC methods compare favorably in most of the brain structures. Conclusion An MR-DUTE-based AC

  7. Assessing the potential of spectral induced polarization to detect in situ changes in iron reduction

    Science.gov (United States)

    Rosier, C. L.; Price, A.; Sharma, S.; Atekwana, E. A.

    2016-12-01

    The near surface geophysical technique Spectral Induced Polarization (SIP), provides promise as an effective method measuring in situ biofilm formation/development. Yet, potential mechanisms responsible for observed shifts in SIP response due to biofilm are not clearly understood. In order to address possible mechanisms we assessed the influence of Shewanella oneidensis (MR1) cell density (colony forming units; CFU), biofilm production (Bradford assay) and iron reduction metabolism (colorimetric assay) on SIP response. Laboratory measurements were collected over three months on columns packed with either iron-coated or iron-free sands and amended with artificial ground water and acetate in order to stimulate biofilm production and microbial iron reduction. Additionally, scanning electron microscopy (SEM) was used to confirm the presence of S. oneidensis cells and biofilm. Our results suggest that during early/initial stage (75 days) of column incubation, SIP measurements revealed that phase and imaginary conductivity responses decreased as the concentration of reduced iron decreased below 2.0 mM. In contrast, we observed only a moderate increase in phase and imaginary conductivity ( 30%) within iron-free columns as a result of increases in S. oneidensis cells (CFU 1.5 x 1011) and biofilm production (7.0 mg ml-1). SEM analysis confirmed the presence of biofilm and cells within both iron-coated and iron-free columns. We hypothesize that the production of microbial metabolic byproducts is a potential mechanism explaining large phase shits observed in previous studies ( 50 mrads) rather than the conductivity of cells or biofilm. Our findings provide support for the following: i) ratio of cells to biofilm production only moderately influences both phase and imaginary conductivity response and ii) largest phase and imaginary conductivity response resulted from microbial metabolism (i.e. iron reduction) and potentially biofilm trapping of conductive materials (i

  8. MR imaging of knee arthritides

    International Nuclear Information System (INIS)

    Stoller, D.W.; Genant, H.K.

    1987-01-01

    T1- and T2-weighted MR images were obtained in five patients with hemophilia, 19 patients with juvenile rheumatoid arthritis, two patients with adult rheumatoid arthritis, four patients with pigmented villonodular synovitis (PVNS), and one patient with lyme arthritis, synovial osteochondromatosis, and Glanzman thrombocytopenia. Pannus formation in synovial hypertrophy imaged low to intermediate in signal intensity on T1- and T2-weighted images. Hemosiderin deposits in PVNS and hemophilia maintained low signal intensity regardless of the pulsing sequence. Early articular erosions and synovitis with irregularity of Hoffa infrapatellar fat pad were detected at an earlier stage and more accurately by MR

  9. MR arthrography gadolinium versus standard MR imaging in rotator cuff pathology

    International Nuclear Information System (INIS)

    Hodler, J.; Brahme, S.K.; Karzel, R.; Cervilla, V.; Snyder, S.; Schweitzer, M.; Flannigan, B.; Resnick, D.

    1990-01-01

    This paper compares the accuracy of MR imaging with and without intraarticular gadolinium in the diagnosis of rotator cuff pathology, using arthroscopy as the gold standard. The authors examined 36 patients, first with T2-weighted sequences and then with T1-weighted sequences after the injection of 15-20 mL of diluted gadolinium. The images were read blindly by three radiologists experienced in musculoskeletal MR imaging. The results were compared with those of arthroscopy. In 16 of 19 arthroscopically intact rotator cuffs, both sequences demonstrated no evidence of rotator cuff tear. The remaining three cases were interpreted as partial or full-thickness tears. Of 12 partial tears, T1-weighted images with intraarticular gadolinium demonstrated a partial tear in five, degeneration in four, a full thickness tear in two, and a normal rotator cuff in one

  10. Mr 40,000 and Mr 39,000 pertussis toxin substrates are increased in surgically denervated dog ventricular myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Hershberger, R.E.; Feldman, A.M.; Anderson, F.L.; Kimball, J.A.; Wynn, J.R.; Bristow, M.R. (Univ. of Utah School of Medicine, Salt Lake City (USA))

    1991-04-01

    To test the general hypothesis that cardiac innervation may participate in myocardial G protein regulation, we examined the effects of complete intrapericardial surgical denervation or sham operation in dogs. In particulate fractions of dog left ventricular (LV) myocardium harvested 28-33 days after denervation or sham operation, Mr 40,000 and Mr 39,000 pertussis toxin-sensitive substrates (G proteins) were increased by 31% (1.31 +/- 0.084 vs 1.00 +/- 0.058 OD, arbitrary units, p less than 0.01) and 40% (1.40 +/- 0.117 vs. 1.000 +/- 0.084 OD, arbitrary units, p less than 0.02), respectively, as compared with sham-operated controls. The Mr 40,000 pertussis toxin-sensitive band comigrated with a pertussis toxin-sensitive substrate in human erythrocyte membranes known to contain an alpha Gi species. In these same preparations basal, GTP and GppNHp stimulated adenylate cyclase activities were decreased in denervated heart by 20, 26, and 19%, respectively, consistent with increased activity of an inhibitory G protein. In contrast, Gs function was not altered, because cyc(-) membranes reconstituted with membrane extracts and fluoride and beta-receptor-stimulated adenylate cyclase activity were not different between groups. Furthermore, adenylate cyclase catalytic subunit function as assessed with forskolin and manganese stimulation was not different between preparations of control and denervated heart. We conclude that in preparations of surgically denervated dog myocardium Mr 40,000 and Mr 39,000 pertussis toxin-sensitive G proteins are increased by 31 and 40%, respectively, and that functional alterations in adenylate cyclase activity exist, consistent with increased inhibitory G-protein function.

  11. Mr 40,000 and Mr 39,000 pertussis toxin substrates are increased in surgically denervated dog ventricular myocardium

    International Nuclear Information System (INIS)

    Hershberger, R.E.; Feldman, A.M.; Anderson, F.L.; Kimball, J.A.; Wynn, J.R.; Bristow, M.R.

    1991-01-01

    To test the general hypothesis that cardiac innervation may participate in myocardial G protein regulation, we examined the effects of complete intrapericardial surgical denervation or sham operation in dogs. In particulate fractions of dog left ventricular (LV) myocardium harvested 28-33 days after denervation or sham operation, Mr 40,000 and Mr 39,000 pertussis toxin-sensitive substrates (G proteins) were increased by 31% (1.31 +/- 0.084 vs 1.00 +/- 0.058 OD, arbitrary units, p less than 0.01) and 40% (1.40 +/- 0.117 vs. 1.000 +/- 0.084 OD, arbitrary units, p less than 0.02), respectively, as compared with sham-operated controls. The Mr 40,000 pertussis toxin-sensitive band comigrated with a pertussis toxin-sensitive substrate in human erythrocyte membranes known to contain an alpha Gi species. In these same preparations basal, GTP and GppNHp stimulated adenylate cyclase activities were decreased in denervated heart by 20, 26, and 19%, respectively, consistent with increased activity of an inhibitory G protein. In contrast, Gs function was not altered, because cyc(-) membranes reconstituted with membrane extracts and fluoride and beta-receptor-stimulated adenylate cyclase activity were not different between groups. Furthermore, adenylate cyclase catalytic subunit function as assessed with forskolin and manganese stimulation was not different between preparations of control and denervated heart. We conclude that in preparations of surgically denervated dog myocardium Mr 40,000 and Mr 39,000 pertussis toxin-sensitive G proteins are increased by 31 and 40%, respectively, and that functional alterations in adenylate cyclase activity exist, consistent with increased inhibitory G-protein function

  12. MR findings in thyroglossal duct cysts

    International Nuclear Information System (INIS)

    Blandino, A.; Salvi, L.; Chirico, G.; Scribano, E.; Longo, M.; Pandolfo, I.

    1990-01-01

    Two patients with thyroglossal duct cysts have been studied with CT and MR. The typical CT feature of these cystic upper-neck lesions are depicted in literature, conversely MR findings are not well known. The homogeneous high intensity on T1-weighted images, higher than simple cyst or fluid, is the most typical feature of the thyroglossal cyst. (author). 12 refs.; 5 figs

  13. Intramuscular metastasis from malignant melanoma: MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Hirohi; Itai, Yuji; Niitsu, Mamoru [Dept. of Radiology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki (Japan); Fujiwara, Masachika; Watanabe, Teruo [Department of Pathology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba (Japan); Satomi, Hisae; Otsuka, Fujio [Department of Dermatology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba (Japan)

    1999-12-01

    We present a rare case of intramuscular metastasis from malignant melanoma. The lesion showed intermediate to high signal intensity on T1-weighted magnetic resonance (MR) images and mixed signal intensities containing high and low signals on T2-weighted images. The signal intensity on T1-weighted images, which is due to the paramagnetic effect of melanin, is a characteristic MR finding of this entity. (orig.)

  14. Visual stimulation, {sup 1}H MR spectroscopy and fMRI of the human visual pathways

    Energy Technology Data Exchange (ETDEWEB)

    Boucard, Christine C.; Cornelissen, Frans W. [University of Groningen, Laboratory for Experimental Ophthalmology, Postbus 30001, Groningen (Netherlands); University of Groningen, BCN Neuro-imaging Center, Postbus 196, Groningen (Netherlands); Mostert, Jop P.; Keyser, Jacques De [University Hospital Groningen, Department of Neurology, Groningen (Netherlands); Oudkerk, Matthijs; Sijens, Paul E. [University Hospital Groningen, Department of Radiology, Groningen (Netherlands)

    2005-01-01

    The purpose was to assess changes in lactate content and other brain metabolites under visual stimulation in optical chiasm, optic radiations and occipital cortex using multiple voxel MR spectroscopy (MRS). {sup 1}H chemical shift imaging (CSI) examinations of transverse planes centered to include the above structures were performed in four subjects at an echo time of 135 ms. Functional MRI (fMRI) was used to confirm the presence of activity in the visual cortex during the visual stimulation. Spectral maps of optical chiasm were of poor quality due to field disturbances caused by nearby large blood vessels and/or eye movements. The optic radiations and the occipital lobe did not show any significant MR spectral change upon visual stimulation, i.e., the peak areas of inositol, choline, creatine, glutamate and N-acetylaspartate were not affected. Reproducible lactate signals were not observed. fMRI confirmed the presence of strong activations in stimulated visual cortex. Prolonged visual stimulation did not cause significant changes in MR spectra. Any signal observed near the 1.33 ppm resonance frequency of the lactate methyl-group was artifactual, originating from lipid signals from outside the volume of interest (VOI). Previous claims about changes in lactate levels in the visual cortex upon visual stimulation may have been based on such erroneous observations. (orig.)

  15. Gadolinium-enhanced cardiac MR exams of human subjects are associated with significant increases in the DNA repair marker 53BP1, but not the damage marker γH2AX.

    Directory of Open Access Journals (Sweden)

    Jennifer S McDonald

    Full Text Available Magnetic resonance imaging is considered low risk, yet recent studies have raised a concern of potential damage to DNA in peripheral blood leukocytes. This prospective Institutional Review Board-approved study examined potential double-strand DNA damage by analyzing changes in the DNA damage and repair markers γH2AX and 53BP1 in patients who underwent a 1.5 T gadolinium-enhanced cardiac magnetic resonance (MR exam. Sixty patients were enrolled (median age 55 years, 39 males. Patients with history of malignancy or who were receiving chemotherapy, radiation therapy, or steroids were excluded. MR sequence data were recorded and blood samples obtained immediately before and after MR exposure. An automated immunofluorescence assay quantified γH2AX or 53BP1 foci number in isolated peripheral blood mononuclear cells. Changes in foci number were analyzed using the Wilcoxon signed-rank test. Clinical and MR procedural characteristics were compared between patients who had a >10% increase in γH2AX or 53BP1 foci numbers and patients who did not. The number of γH2AX foci did not significantly change following cardiac MR (median foci per cell pre-MR = 0.11, post-MR = 0.11, p = .90, but the number of 53BP1 foci significantly increased following MR (median foci per cell pre-MR = 0.46, post-MR = 0.54, p = .0140. Clinical and MR characteristics did not differ significantly between patients who had at least a 10% increase in foci per cell and those who did not. We conclude that MR exposure leads to a small (median 25% increase in 53BP1 foci, however the clinical relevance of this increase is unknown and may be attributable to normal variation instead of MR exposure.

  16. Evaluation and characterization of advanced rice mutant line of rice (Oryza sativa), MR219-4 and MR219-9 under drought condition

    International Nuclear Information System (INIS)

    Abdul Rahim Harun; Zarith Shafika Kamarudin; Abdullah, M.Z.; Anna, L.P.K.; Sobri Hussain; Rusli Ibrahim; Khairuddin abdul Rahim

    2012-01-01

    Two advance rice mutant lines, MR219-4 and MR219-9 derived from mutagenesis of Oryza sativa cv. MR219 with gamma radiation at 300 Gy were evaluated in simulated drought condition in the greenhouse at Malaysian Nuclear Agency. The mutants were evaluated simultaneously with ARN1, a drought resistant variety and MR211 a susceptible cultivar as a check. Randomized complete block design with three replicates was used in the experiment. The evaluation and selection were done based on leaf rolling and leaf drying as well as other agronomic traits, such as, number of tillers per plant, plant height, flag leaf area, grain weight per plant, grain yield per plant, 100-grain weight, harvest index, panicle length and plant biomass. The mutants MR219-4 showed moderate tolerance and MR219-9 showed tolerance to drought respectively as compare to the check variety (ARN1, MR211) and control MR219. Leaf rolling, leaf drying, days to flowering and days to maturity are valuable secondary traits that may provide additional information for selection because of associating with the plant survival under water stress. Further research on expression of drought-tolerant lines under different drought conditions is essential in order to identify particular traits that are associated with drought tolerance and high yield potential. Similarly the importance of secondary traits, relative to other putative traits for drought tolerance, needs to be tested in various environments. (author)

  17. Diagnosis of intraductal spread of breast cancer by high-resolution MR imaging. Correlation between MR imaging and pathohistological findings

    International Nuclear Information System (INIS)

    Date, Shuji

    1998-01-01

    The main purpose of this study was to investigate pathohistological factors that affect the MR findings of intraductal spread (IDS) of breast cancer. The subjects of the present study were 42 breast cancer patients who were examined by MR imaging. Fat-suppressed high-resolution T1-weighted spin-echo images (350/13/1 (TR/TE/excitations), 16-cm FOV, 5-mm section thickness, and 512 x 256 matrix) were obtained one minute after the intravenous administration of Gd-DTPA. In this protocol, contrast determination time was 1 min 48 sec. Of the 42 cases, IDS was found to be located more than 1 cm from the primary focus in 22 cases (52%). Rates of sensitivity, specificity and accuracy of MR imaging for the detection of IDS were 82%, 80%, and 81%, respectively. The probable cause of misdiagnosis was parenchymal enhancement due to severe fibrocystic disease and normal menstrual cycle. In 21 of 42 cases, the MR findings were precisely correlated with the pathohistologic findings of almost the same cross-section. The MR findings of IDS varied greatly with observation of linear, band-like, branch-like, plate-like and minute ring enhancements. These findings closely reflected the size, aggregation pattern, and distribution of intraductal lesions. In particular, minute ring enhancement was only observed in 4 comedo-type lesions. This pattern of enhancement is considered to reflect elevated intraductal cellular density with necrosis in the central region. (author)

  18. Diagnosis of intraductal spread of breast cancer by high-resolution MR imaging. Correlation between MR imaging and pathohistological findings

    Energy Technology Data Exchange (ETDEWEB)

    Date, Shuji [Hiroshima City Hospital (Japan)

    1998-04-01

    The main purpose of this study was to investigate pathohistological factors that affect the MR findings of intraductal spread (IDS) of breast cancer. The subjects of the present study were 42 breast cancer patients who were examined by MR imaging. Fat-suppressed high-resolution T1-weighted spin-echo images (350/13/1 (TR/TE/excitations), 16-cm FOV, 5-mm section thickness, and 512 x 256 matrix) were obtained one minute after the intravenous administration of Gd-DTPA. In this protocol, contrast determination time was 1 min 48 sec. Of the 42 cases, IDS was found to be located more than 1 cm from the primary focus in 22 cases (52%). Rates of sensitivity, specificity and accuracy of MR imaging for the detection of IDS were 82%, 80%, and 81%, respectively. The probable cause of misdiagnosis was parenchymal enhancement due to severe fibrocystic disease and normal menstrual cycle. In 21 of 42 cases, the MR findings were precisely correlated with the pathohistologic findings of almost the same cross-section. The MR findings of IDS varied greatly with observation of linear, band-like, branch-like, plate-like and minute ring enhancements. These findings closely reflected the size, aggregation pattern, and distribution of intraductal lesions. In particular, minute ring enhancement was only observed in 4 comedo-type lesions. This pattern of enhancement is considered to reflect elevated intraductal cellular density with necrosis in the central region. (author)

  19. H-1 MR spectroscopic imaging detects prolonged elevation of lactate and increased Ch/NAA ratio in patients with focal cerebral ischemia

    International Nuclear Information System (INIS)

    van Rijen, P.C.; Tulleken, C.A.F.; den Hollander, J.A.; Luyten, P.R.

    1989-01-01

    H-1 MR spectroscopy of patients with a recent stroke (range, 78 hours to 18 days after stroke) showed an increased Ch/NAA ratio in a large ischemic region of the brain, while lactate was increased in the center of the infarct. A spectroscopic image taken 8 months after the stroke did not show any increased lactate; however, the Ch/NAA ratio image still showed increased intensity even in regions that looked normal on the MR images. H-1 MR spectra measured during clinical recovery (range 10-48 days) still showed elevated lactate compared with control regions, although lactate was lower than in the acute phase. This suggests on ongoing anaerobic glycolysis in the metabolically compromised penumbra

  20. Predictive value of MR imaging-dependent and non-MR imaging-dependent parameters for recurrence of laryngeal cancer after radiation therapy

    NARCIS (Netherlands)

    Castelijns, J. A.; van den Brekel, M. W.; Smit, E. M.; Tobi, H.; van Wagtendonk, F. W.; Golding, R. P.; Venema, H. W.; van Schaik, C.; Snow, G. B.

    1995-01-01

    To determine the predictive value of several clinical and radiologic parameters for recurrence of laryngeal cancer. Eighty previously untreated patients underwent magnetic resonance (MR) imaging before radiation therapy with curative intent. Tumor volume was calculated from T1-weighted MR images.

  1. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    International Nuclear Information System (INIS)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon

    1994-01-01

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days

  2. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon [Inje University College of Medicine, Pusan (Korea, Republic of)

    1994-08-15

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days.

  3. MR imaging of neonatal cerebral infarction

    International Nuclear Information System (INIS)

    McArdle, C.B.; Mehta, S.D.; Kulkarni, M.V.; Keeney, S.A.; Hayden, C.K.; Adcock, E.W. III.

    1987-01-01

    Twenty-six neonatal infarcts were imaged with 0.6 T and 1.5-T magnets and correlated with US and/or CT. Periventricular leukomalacia (PVL) was seen in six cases: lobar infarction, ten cases; global infarction, six cases; and basal ganglia infarction, four cases. MR imaging was superior to US and CT in detecting hemorrhagic PVL and basal ganglia infarcts. MR demonstrates lobar infarcts better than US and CT because of a wider field of view, specificty, and improved gray and white matter differentiation. US underestimates the extent of brain destruction in global infarcts. These results indicate that MR is the single best imaging modality for detecting ischemic brain injury

  4. The principles of quantification applied to in vivo proton MR spectroscopy

    International Nuclear Information System (INIS)

    Helms, Gunther

    2008-01-01

    Following the identification of metabolite signals in the in vivo MR spectrum, quantification is the procedure to estimate numerical values of their concentrations. The two essential steps are discussed in detail: analysis by fitting a model of prior knowledge, that is, the decomposition of the spectrum into the signals of singular metabolites; then, normalization of these signals to yield concentration estimates. Special attention is given to using the in vivo water signal as internal reference

  5. MR inflow angiography for the evaluation of dural sinus patency

    International Nuclear Information System (INIS)

    Poncelet, B.; Baleriaux, D.; Grand, C.; Van Dijk, P.; De Graaf, R.; Segebarth, C.

    1990-01-01

    This paper assesses dural sinus patency with two-dimensional inflow MR angiography. Twelve patients with potential dural sinus (superior sagittal and transverse sinus) involvement related to tumors of the falx or the convexity (meningiomas, metastasis) were examined with digital subtraction angiography (DSA), Mr imaging (1.5-T Gyroscan system), including T1-weighted (pre- and post-agadolinium) and T2-weighted spin-echo imaging, and MR angiography. For the MR angiographic study, a gradient-echo fast field echo sequence with flow compensation was used. Thin (2-mm), contiguous coronal or transverse sections were acquired sequentially. Three-dimensional reconstruction with MIP processing was then performed. CT, DSA, and MR imaging were performed for presurgical evaluation. Surgical confirmation of sinus patency was obtained for all patients

  6. MR imaging of the pediatric central nervous system utilization review

    International Nuclear Information System (INIS)

    Barnes, P.D.; Prince, J.R.; Galloway, D.C.; Ross-Duggan, J.; Lester, P.D.; Yamanashi, W.S.

    1986-01-01

    MR has been done in over 500 pediatric and adolescent patients (ages 5 days to 20 years) with central nervous system (CNS) disease (brain, n = 331; spine, n = 218), including high-field and special coil application in 362 cases. T1-weighted, multiplanar MR imaging provides superior anatomic delineation of organogenetic CNS malformations, while multiparameter (T1, T2, p) MR is usually necessary for more complete characterization of histogenetic malformations, as well as acquired conditions. MR imaging is a desirable method for the initial and definitive evaluation of many cranial and spinal conditions of childhood (more-invasive procedures were obviated in 164 patients). CT or other modalities may be added when MR imaging does not satisfy the clinical query

  7. Normal anatomy and MR findings of fetal main organs at MR imaging

    International Nuclear Information System (INIS)

    Xia Liming; Zou Mingli; Feng Dingyi; Hu Junwu; Qi Jianpin; Wang Chengyuan

    2005-01-01

    Objective: To investigate normal anatomy and MR findings of fetal main organs. Methods: Forty-seven fetus underwented fast MR imaging, SSFSE sequence was used, the normal anatomy and MR findings of fetal main organs was observed in different gestational age. The organs included: brain, lungs, heart, liver, spleen, gastrointestinal tract, urinary collecting systems, bladder, bones, spine, and subcutaneous fat. Results: Results of MR in 47 fetus showed that the main organs had developed by 20-week-old fetus, about 20 weeks gestation, cerebral cortical surface was smooth, no cortical gyri and sulci, then cortical gyri and sulci developed slowly. The lungs, trachea, bronchus, gastrointestinal tract, renal collecting system and bladder showed high signal intensity; the heart, great vessels, liver, spleen, bones and muscles appeared hypointense; the kidneys appeared isointense, the spine had developed and subcutaneous fat was seen in 20-week-old fetus, the subcutaneous fat increased with fetus maturating. Conclusion: Normal anatomy and MR findings of fetal main organs were clearly showed by fast MR imaging, and they are different from the newborns. (authors)

  8. Evaluation of fetal anomalies with MR imaging

    International Nuclear Information System (INIS)

    Benson, R.C.; Platt, L.D.; Colletti, P.M.; Raval, J.K.; Boswell, W.D. Jr.; Halls, J.M.

    1987-01-01

    Twenty pregnant women underwent MR imaging (0.5 T) after US disclosed a significant fetal anomaly. The ability of MR imaging to depict the abnormalities was assessed. Of 20 abnormalities, 17 were visualized with MR imaging. Abnormalities included conjoined twins, omphalocele, gastroschisis, hydrocephalus, hydronephrosis, fetal ascites, facial teratoma, anencephaly, bladder outlet obstruction, thanatophoric dwarfism, cystic, hygroma, and fetal ovarian cyst. Thirteen of 14 abnormalities in third-trimester fetuses were visualized, as were four of six abnormalities in second-trimester fetuses. Associated polyhydramnios or oligohydramnios was evident in six of six cases. Anomalies were best delineated with T1-weighted sequences. The study suggests that MR imaging is potentially useful as a complementary imaging modality in the evaluation of fetal anomalies

  9. MR imaging of acute hemorrhagic brain infarction

    International Nuclear Information System (INIS)

    Uchino, Akira; Ohnari, Norihiro; Ohno, Masato

    1989-01-01

    Six patients with acute hemorrhagic brain infarct were imaged using spin-echo (SE) pulse sequences on a 1.5 Tesla MR scanner. Including two patients with repeated MR imaging, a total of eight examinations, all performed within 15 days after stroke, were analyzed retrospectively. Four patients revealed massive hemorrhages in the basal ganglia or cerebellum and three cases demonstrated multiple linear hemorrhages in the cerebral cortex. On T1-weighted images, hemorrhages were either mildly or definitely hyperintense relative to gray matter, while varied from mildly hypointense to hyperintense on T2-weighted images. T1-weighted images were superior to T2-weighted images in detection of hemorrhgage. CT failed to detect hemorrhage in two of five cases: indicative of MR superiority to CT in the diagnosis of acute hemorrhagic infarcts. (author)

  10. MR appearance of skeletal neoplasms following cryotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, M.L. [Dept. of Radiology SB-05, Washington Univ., Seattle, WA (United States); Lough, L.R. [Pitts Radiological Associates, Columbia, SC (United States); Shuman, W.P. [Dept. of Radiology, Medical Center Hospital of Vermont, Burlington, VT (United States); Lazerte, G.D. [Dept. of Pathology RC-72, Washington Univ., Medical Center Hospital of Vermont, Burlington, VT (United States); Conrad, E.U. [Dept. of Orthopedic Surgery RK-10, Washington Univ., Medical Center of Vermont, Burlington, VT (United States)

    1994-02-01

    Cryotherapy is an increasingly popular mode of therapy adjunctive to surgical curettage in the treatment of certain skeletal neoplasms, such as giant cell tumors or chondrosarcomas. The magnetic resonance (MR) findings following cryotherapy have not been previously reported. We reviewed the MR findings in seven patients with skeletal neoplasms following curettage and cryotherapy. In six cases we found a zone of varying thickness extending beyond the surgical margins, corresponding to an area of cryoinjury to medullary bone. This zone displayed low signal intensity on T1-weighted images and high signal intensity on T2-weighted images, consistent with the presence of marrow edema. This zone of edema almost certainly reflects underlying thermal osteonecrosis. This zone may vary in size and intensity over time as the area of cryoinjury evolves or resolves. MR is currently the imaging procedure of choice for follow-up of most musculoskeletal neoplasms. Knowledge of the MR findings following cryotherapy should help prevent confusion during the interpretation of follow-up MR examinations. (orig.)

  11. MR appearance of skeletal neoplasms following cryotherapy

    International Nuclear Information System (INIS)

    Richardson, M.L.; Lough, L.R.; Shuman, W.P.; Lazerte, G.D.; Conrad, E.U.

    1994-01-01

    Cryotherapy is an increasingly popular mode of therapy adjunctive to surgical curettage in the treatment of certain skeletal neoplasms, such as giant cell tumors or chondrosarcomas. The magnetic resonance (MR) findings following cryotherapy have not been previously reported. We reviewed the MR findings in seven patients with skeletal neoplasms following curettage and cryotherapy. In six cases we found a zone of varying thickness extending beyond the surgical margins, corresponding to an area of cryoinjury to medullary bone. This zone displayed low signal intensity on T1-weighted images and high signal intensity on T2-weighted images, consistent with the presence of marrow edema. This zone of edema almost certainly reflects underlying thermal osteonecrosis. This zone may vary in size and intensity over time as the area of cryoinjury evolves or resolves. MR is currently the imaging procedure of choice for follow-up of most musculoskeletal neoplasms. Knowledge of the MR findings following cryotherapy should help prevent confusion during the interpretation of follow-up MR examinations. (orig.)

  12. Reflex sympathetic dystrophy syndrome: MR imaging study

    International Nuclear Information System (INIS)

    Masciocchi, C.; Fascetti, E.; Bonanni, G.; Calvisi, V.; Buoni, C.; Passariello, R.

    1987-01-01

    Reflex sympathetic dystrophy syndrome (RSDS) is characterized by pain, swelling, and limitation of motion. The etiology and pathophysiology mechanism have not yet been identified. We considered eight patients with clinical signs of RSDS, in five cases located at the knee joint and in three cases in the hip. In all cases conventional radiography and radionuclide bone scanning were performed before MR imaging. Conventional radiography was negative in three cases while scintigraphy demonstrated the lesion in all patients. MR imaging showed an area of low intensity signal on T1-weighted scans and an increased signal intensity on T2-weighted images. This area is located at the bone marrow and its regular and homogeneous. This specific finding on MR images is due to reflect edema by hyperemia of the bone marrow. The MR imaging diagnosis was confirmed on clinical and radiological follow-up. MR imaging can have a role in the differential diagnosis when other studies are nondiagnostic or nonspecific for RSDS

  13. Proton range shift analysis on brain pseudo-CT generated from T1 and T2 MR.

    Science.gov (United States)

    Pileggi, Giampaolo; Speier, Christoph; Sharp, Gregory C; Izquierdo Garcia, David; Catana, Ciprian; Pursley, Jennifer; Amato, Francesco; Seco, Joao; Spadea, Maria Francesca

    2018-05-29

    In radiotherapy, MR imaging is only used because it has significantly better soft tissue contrast than CT, but it lacks electron density information needed for dose calculation. This work assesses the feasibility of using pseudo-CT (pCT) generated from T1w/T2w MR for proton treatment planning, where proton range comparisons are performed between standard CT and pCT. MR and CT data from 14 glioblastoma patients were used in this study. The pCT was generated by using conversion libraries obtained from tissue segmentation and anatomical regioning of the T1w/T2w MR. For each patient, a plan consisting of three 18 Gy beams was designed on the pCT, for a total of 42 analyzed beams. The plan was then transferred onto the CT that represented the ground truth. Range shift (RS) between pCT and CT was computed at R 80 over 10 slices. The acceptance threshold for RS was according to clinical guidelines of two institutions. A γ-index test was also performed on the total dose for each patient. Mean absolute error and bias for the pCT were 124 ± 10 and -16 ± 26 Hounsfield Units (HU), respectively. The median and interquartile range of RS was 0.5 and 1.4 mm, with highest absolute value being 4.4 mm. Of the 42 beams, 40 showed RS less than the clinical range margin. The two beams with larger RS were both in the cranio-caudal direction and had segmentation errors due to the partial volume effect, leading to misassignment of the HU. This study showed the feasibility of using T1w and T2w MRI to generate a pCT for proton therapy treatment, thus avoiding the use of a planning CT and allowing better target definition and possibilities for online adaptive therapies. Further improvements of the methodology are still required to improve the conversion from MRI intensities to HUs.

  14. MR imaging findings of renal capsular leiomyoma : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dal Mo; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Jin Woo; Cho, Hyun I; Lee, Jong Bouk [Gachon Medical college Gil Medical Center, Seoul (Korea, Republic of)

    1999-06-01

    In the literature, descriptions of the MR findings of renal leiomyoma are rare. We present the MR findings of a capsular leiomyoma of the kidney in which hypointensity relative to normal renal parenchyma was seen on both T1-and T2-weighted MR images.

  15. MR imaging findings of renal capsular leiomyoma : a case report

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Jin Woo; Cho, Hyun I; Lee, Jong Bouk

    1999-01-01

    In the literature, descriptions of the MR findings of renal leiomyoma are rare. We present the MR findings of a capsular leiomyoma of the kidney in which hypointensity relative to normal renal parenchyma was seen on both T1-and T2-weighted MR images

  16. MR in phenylketonuria-related brain lesions

    International Nuclear Information System (INIS)

    Dezortova, M.; Hajek, M.; Tintra, J.; Hejcmanova, L.; Sykova, E.

    2001-01-01

    Purpose: Phenylketonuria (PKU) patients were examined by different MR techniques to explain the pathological changes observed in periventricular white brain matter using conventional MR imaging. Material and Methods: Fifteen patients with treated classical PKU were examined by 1 H spectroscopy, relaxometry and diffusion imaging on a whole-body 1.5-T MR imager. Results: Known PKU lesions characterized by T2 enhancement in periventricular white matter were observed in all patients. The MR spectra from the lesioned areas showed a significant decrease in choline concentration. The mean ADC of water decreased and tortuosity increased in PKU lesions compared to control data. Conclusion: The results support the following hypothesis: The T2 increase in the PKU lesion reflects a raised concentration of free water molecules (about 15%) that have an increased trajectory between collisions compared to the same region in controls. The increase in water mobility might be explained by changes in extracellular space volume and myelin sheaths, which, presumably, have a different geometry with more hydrophobic sites in PKU patients. The changes result in increased tortuosity and may be confirmed by the loss of anisotropy in PKU lesions

  17. MR in phenylketonuria-related brain lesions

    Energy Technology Data Exchange (ETDEWEB)

    Dezortova, M.; Hajek, M.; Tintra, J. [Inst. for Clinical and Experimental Medicine, Prague (Czech Republic); Hejcmanova, L. [Charles University, Prague (Czech Republic). 3rd Medical Faculty; Sykova, E. [Charles University, Prague (Czech Republic). 2nd Medical Faculty

    2001-09-01

    Purpose: Phenylketonuria (PKU) patients were examined by different MR techniques to explain the pathological changes observed in periventricular white brain matter using conventional MR imaging. Material and Methods: Fifteen patients with treated classical PKU were examined by {sup 1}H spectroscopy, relaxometry and diffusion imaging on a whole-body 1.5-T MR imager. Results: Known PKU lesions characterized by T2 enhancement in periventricular white matter were observed in all patients. The MR spectra from the lesioned areas showed a significant decrease in choline concentration. The mean ADC of water decreased and tortuosity increased in PKU lesions compared to control data. Conclusion: The results support the following hypothesis: The T2 increase in the PKU lesion reflects a raised concentration of free water molecules (about 15%) that have an increased trajectory between collisions compared to the same region in controls. The increase in water mobility might be explained by changes in extracellular space volume and myelin sheaths, which, presumably, have a different geometry with more hydrophobic sites in PKU patients. The changes result in increased tortuosity and may be confirmed by the loss of anisotropy in PKU lesions.

  18. MR imaging of leukoencephalopathy in the pediatric brain

    International Nuclear Information System (INIS)

    te Strake, L.; Brismar, J.; Coates, R.; Gascon, G.; Ozand, P.; Greer, W.; Haider, A.

    1989-01-01

    The authors have studied 58 children with white matter disease (WMD) on 1.5-T MR imaging. CT was available for comparison in 36 patients. Presence of WMD was assessed 12 anatomic areas. In the adult-type brain, CT was negative in 76% (infratentorial WMD) and 49% (supratentorial WMD) of positive MR scores; the difference between positive MR and CT scores was significant (P < .001). In the immature brain, corresponding percentages were 58% and 34%, respectively. In the immature brain, CEFAST and/or T1-weighted spin-echo sequences were found to give valuable additional information to T2-weighted spin-echo data

  19. Gadolinium-enhanced MR imaging in evaluation of cholesteatoma

    International Nuclear Information System (INIS)

    Sugihara, M.; Sugimura, K.; Ishida, T.; Fujino, A.; Miyakuni, Y.

    1990-01-01

    It was sometimes difficult to differentiate cholesteatoma from accompanied granuloma, cholesterol granuloma, or mastoiditis on high-resolution CT. This study was designed to assess the reliability with which cholesteatoma can be differentiated from those accompanied lesions by gadolinium-enhanced MR imaging. Eight patients suspected to have cholesteatoma were evaluated with GD-DTPA-enhanced MR imaging with a 1.5-T MR imaging GE Signa unit. axial pre- and postcontrast T1-weighted (TR/TE, 600/20) and T2-weighted (TR/TE, 2,000/70) images were studied. MR imaging findings were compared with histologic findings (13 lesions), which included cholesteatoma (n = 6), granuloma (n = 4), cholesterol granuloma (n = 2), and mastoiditis (n = 1). Cholesteatoma had an intermediate to high signal intensity (SI) similar to that of granuloma on both T1- and T2-weighted images. Cholesterol granulomas showed high SI on both T1- and T2-weighted images. Mastoiditis demonstrated marked high SI on T2-weighted images. Cholesterol granuloma and mastoiditis can be distinguished from cholesteatoma or granuloma on both T1- and T2-weighted images. On Gd-DTPA-enhanced images, there was marked enhancement of all granulomas. However, no cholesteatoma enhancement was seen in all six lesions. Gd-DTPA-enhanced images were able to distinguish cholesteatoma from granuloma and to estimate the exact extent of cholesteatoma. Gd-DTPA-enhanced MR imaging is valuable in the evaluation and management of cholesteatoma

  20. An MR-compatible neonatal incubator.

    Science.gov (United States)

    Paley, M N J; Hart, A R; Lait, M; Griffiths, P D

    2012-07-01

    To develop a neonatal MR-compatible incubator for transporting babies between a neonatal intensive care unit and an MRI unit that is within the same hospital but geographically separate. The system was strapped to a standard MR-compatible patient trolley, which provides space for resuscitation outside the incubator. A constant-temperature exothermic heat pad was used to maintain temperature together with a logging fluoro-optic temperature monitor and alarm system. The system has been designed to accommodate standard knee-sized coils from the major MR manufacturers. The original incubator was constructed from carbon fibre, but this required modification to prevent radiofrequency shading artefacts due to the conducting properties of the carbon fibre. A high-tensile polyester material was used, which combined light weight with high impact strength. The system could be moved onto the patient bed with the coils and infant in place by one technologist. Studies in eight neonatal patients produced high quality 1.5 T MR images with low motion artefacts. The incubator should also be compatible with imaging in 3 T MR systems, although further work is required to establish this. Images were acquired using both rapid and high-resolution sequences, including three-dimensional volumes, proton spectra and diffusion weighting. The incubator provides a safe, quiet environment for neonates during transport and imaging, at low cost.

  1. Value of ultrasonography, Ct and MR imaging in the diagnosis of primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Tziakouri, C.; Eracleous, E.; Skannavis, S.; Pierides, A.; Symeonides, P.; Gourtsoyiannis, N.

    1996-01-01

    Purpose: To evaluate the significance of preoperative localization of abnormal parathyroid glands to the surgical outcome in patients with primary hyperparathyroidism. Material and Methods: Thirty-nine patients with primary hyperparathyroidism were studied preoperatively with US (39 patients), CT (30 patients) and MR imaging (18 patients). The overall diagnostic accuracy for US was 87%, CT 66% and MR 94%. In patients with a single parathyroid adenoma US was the most cost-effective localization technique with a detection rate of 96%. CT had a lower detection rate (78%) but was of particular value for fairly large ectopic adenomas in the root of the neck. MR imaging was a good confirmatory test (93%). In patients with multiple gland disease (primary hyperplasia and multiple adenomas), no single localization study alone was sufficient. Combination of all 3 studies, however, alerted the physician to the presence of disease in more than one gland in 87% of these patients. Conclusion: US, CT and MR imaging followed by surgery performed by an experienced surgeon provided good clinical results in 39 patients with primary hyperparathyroidism. Preoperative localization was especially useful in patients with primary parathyroid hyperplasia or multiple adenomas and in patients with ectopic parathyroid adenomas in the root of the neck. We recommend identification of all abnormal parathyroid glands prior to surgery. (orig.)

  2. Proton MR spectroscopy of hyperplastic hematopoietic marrow in aplastic anemia

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan); Arai, Nobuyuki

    1997-04-01

    The purpose of this study was to compare the findings of magnetic resonance (MR) spectroscopy of hyperplastic hematopoietic marrow with those of normal bone marrow. Twenty-four samples of normal marrow from eight control subjects and 19 samples of hyperplastic marrow in aplastic anemia were examined with a 1.5 T MR unit. The former showed low intensity on opposed-phase T1-weighted images, while the latter showed high intensity on both fast STIR and opposed-phase T1-weighted images. MR spectroscopy quantitatively confirmed that the water; fat ratio was increased and the transverse relaxation time of water was changed in hyperplastic bone marrow, compared with normal bone marrow. In summary, MR imaging is able to detect hematopoietic regions among a wide range of bone marrow of aplastic anemia, while MR spectroscopy allowed us to quantitatively analyze the cell population of hyperplastic hematopoietic marrow in aplastic anemia. (author)

  3. Proton MR spectroscopy of hyperplastic hematopoietic marrow in aplastic anemia

    International Nuclear Information System (INIS)

    Amano, Yasuo; Kumazaki, Tatsuo; Arai, Nobuyuki.

    1997-01-01

    The purpose of this study was to compare the findings of magnetic resonance (MR) spectroscopy of hyperplastic hematopoietic marrow with those of normal bone marrow. Twenty-four samples of normal marrow from eight control subjects and 19 samples of hyperplastic marrow in aplastic anemia were examined with a 1.5 T MR unit. The former showed low intensity on opposed-phase T1-weighted images, while the latter showed high intensity on both fast STIR and opposed-phase T1-weighted images. MR spectroscopy quantitatively confirmed that the water; fat ratio was increased and the transverse relaxation time of water was changed in hyperplastic bone marrow, compared with normal bone marrow. In summary, MR imaging is able to detect hematopoietic regions among a wide range of bone marrow of aplastic anemia, while MR spectroscopy allowed us to quantitatively analyze the cell population of hyperplastic hematopoietic marrow in aplastic anemia. (author)

  4. MR findings of bowlegs in toddlers

    International Nuclear Information System (INIS)

    Iwasawa, Tae; Inaba, Yutaka; Kameshita, Kikuo; Nishimura, Gen; Aida, Noriko; Matsubara, Sho

    1999-01-01

    Background. Toddlers with severe physiologic tibial bowing are considered to be at risk for the development of Blount's disease. Objective. To correlate MR findings of the knee with the clinical outcome in toddlers with severe physiological tibial bowing. Materials and methods. MR findings were evaluated in 22 affected legs of 14 children with severe tibial bowing (mean age 1.9 years). In 18 affected legs, MR findings were compared with the transition of the tibial metaphyseal-diaphyseal angle (MDA) and tibiofemoral angle (TFA) measured serially between 2 and 3 years of age. Results. MR findings of severe tibial bowing comprised undulation of the posteromedial physis of the tibia (3/22), signal alterations in the medial tibial metaphysis (10/22), T2 prolongation in the posteromedial tibial epiphyseal cartilage (14/22) and signal changes in the medial menisci (18/22). The decrease in the TFA was different in the legs with and without increased signal in the epiphyseal cartilage, and the decrease in the MDA was different in the legs with and without physeal undulation. Conclusion. MR imaging findings can predict the retarded resolution of tibial bowing, which may be a risk factor for the development of Blount's disease. (orig.)

  5. Functional characterization of 5-HT1B receptor drugs in nonhuman primates using simultaneous PET-MR

    DEFF Research Database (Denmark)

    Hansen, Hanne D.; Mandeville, Joseph B.; Sander, Christin Y.

    2017-01-01

    In the present study, we used a simultaneous PET-MR experimental design to investigate the effects of functionally different compounds (agonist, partial agonist, and antagonist) on 5-HT1B receptor (5-HT1BR) occupancy and the associated hemodynamic responses. In anesthetized male nonhuman primates...

  6. Coronary Artery Anomalies and Variants: Technical Feasibility of Assessment with Coronary MR Angiography at 3 T1

    Science.gov (United States)

    Gharib, Ahmed M.; Ho, Vincent B.; Rosing, Douglas R.; Herzka, Daniel A.; Stuber, Matthias; Arai, Andrew E.; Pettigrew, Roderic I.

    2008-01-01

    The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant study was approved by the local institutional review board, and informed consent was obtained from all participants. Twenty-two participants (11 men, 11 women; age range, 18–62 years) were included. Ten participants were healthy volunteers, whereas 12 participants were patients suspected of having CAAV. Coronary MR angiography was performed with a 3-T MR imager. A 3D free-breathing navigator-gated and vector electrocardiographically–gated segmented k-space gradient-echo sequence with adiabatic T2 preparation pulse and parallel imaging (sensitivity encoding) was used. Whole-heart acquisitions (repetition time msec/echo time msec, 4/1.35; 20° flip angle; 1 × 1 × 2-mm acquired voxel size) lasted 10–12 minutes. Mean examination time was 41 minutes ± 14 (standard deviation). Findings included aneurysms, ectasia, arteriovenous fistulas, and anomalous origins. The 3D whole-heart acquisitions developed for use with 3 T are feasible for use in the assessment of CAAV. © RSNA, 2008 PMID:18372470

  7. Perinatal Hypoxic-Ischemic brain injury; MR findings

    International Nuclear Information System (INIS)

    Park, Dong Woo; Seo, Chang Hye

    1994-01-01

    To characterize the MR findings of hypoxic-ischemic brain injury and to assess the value of the MR imaging. SE T1-, T2-weighted, and IR brain MR images of 44 infants and children with the past history of perinatal hypoxic insults were reviewed. Abnormal brain MR findings of 8 patients with birth history of prematurity and 36 patients with birth history of full-term/posterm including 7 with severe anoxic insult history, were compared in regard to the location and the character of the lesions. MRI demonstrated the followings; (1)abnormal signal intensity lesions of subcortical and/or deep cerebral white matter, cortex, and deep gray matter, (2)atrophy of the cerebral white matter, cortex and corpus callosum, with/without ventriculomegaly, and (3)delay in myelination. Periventricular and deep white matter lesions were demonstrated in the prematurity, the deep white matter lesions and/ or subcortical white matter lesions in the term/post-term, and deep gray matter lesions in the 7 patients with severe anoxic insults history. MR imaging was useful in the diagnosis of the hypoxic-ischemic brain injury, and the white and gray matter lesions were correlated with the time of the injury and the severity of hypoxic insult

  8. MO-F-CAMPUS-J-04: Tissue Segmentation-Based MR Electron Density Mapping Method for MR-Only Radiation Treatment Planning of Brain

    Energy Technology Data Exchange (ETDEWEB)

    Yu, H [Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Lee, Y [Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Ruschin, M [Odette Cancer Centre, Toronto, ON (Canada); Karam, I [Sunnybrook Odette Cancer Center, Toronto, Ontario (Canada); Sahgal, A [University of Toronto, Toronto, ON (Canada)

    2015-06-15

    Purpose: Automatically derive electron density of tissues using MR images and generate a pseudo-CT for MR-only treatment planning of brain tumours. Methods: 20 stereotactic radiosurgery (SRS) patients’ T1-weighted MR images and CT images were retrospectively acquired. First, a semi-automated tissue segmentation algorithm was developed to differentiate tissues with similar MR intensities and large differences in electron densities. The method started with approximately 12 slices of manually contoured spatial regions containing sinuses and airways, then air, bone, brain, cerebrospinal fluid (CSF) and eyes were automatically segmented using edge detection and anatomical information including location, shape, tissue uniformity and relative intensity distribution. Next, soft tissues - muscle and fat were segmented based on their relative intensity histogram. Finally, intensities of voxels in each segmented tissue were mapped into their electron density range to generate pseudo-CT by linearly fitting their relative intensity histograms. Co-registered CT was used as a ground truth. The bone segmentations of pseudo-CT were compared with those of co-registered CT obtained by using a 300HU threshold. The average distances between voxels on external edges of the skull of pseudo-CT and CT in three axial, coronal and sagittal slices with the largest width of skull were calculated. The mean absolute electron density (in Hounsfield unit) difference of voxels in each segmented tissues was calculated. Results: The average of distances between voxels on external skull from pseudo-CT and CT were 0.6±1.1mm (mean±1SD). The mean absolute electron density differences for bone, brain, CSF, muscle and fat are 78±114 HU, and 21±8 HU, 14±29 HU, 57±37 HU, and 31±63 HU, respectively. Conclusion: The semi-automated MR electron density mapping technique was developed using T1-weighted MR images. The generated pseudo-CT is comparable to that of CT in terms of anatomical position of

  9. Evaluation of ambiguous genitalia with MR imaging

    International Nuclear Information System (INIS)

    Secaf, E.; Nuruddin, R.; Hricak, H.; Conte, F.A.

    1989-01-01

    To assess the potential of MR imaging in the evaluation of patients with ambiguous genitalia. Twenty-three consecutive patients with ambiguous genitalia at birth or phenotypic anomalies at puberty were included in this study. MR imaging was performed on a 1.5-T unit using T1- (600/30) and T2- (2,500/70) weighted sequences. In patients aged 5 years or less, 3-mm contiguous sagittal and transaxial sections were obtained. The same imaging planes at 5-mm intervals were obtained in older patients. MR findings were compared to those of surgery (n = 14) or biochemical assays (n = 9). Diagnoses included true hermaphroditism (n = 2), pseudohermaphroditism (n = 6), Turner syndrome (n = 2), testicular feminization (n = 2), adrenogenital syndrome (n = 3), vaginal agenesis (n = 3), cloacal abnormality (n = 2), microphallus (n = 2), and double phallus (n = 1. MR imaging correctly identified the presence or absence of the vagina (n = 10) and uterus (n = 9), thus helping in the diagnosis and management of patients with ambiguous genitalia. Demonstration of development of corpora cavernosa, corpora spongiosa, undescended testis, or partial vaginal agenesis assisted in the surgical approach

  10. Appearance of abdominal wall endometriosis on MR imaging

    International Nuclear Information System (INIS)

    Busard, Milou P.H.; Kuijk, Cees van; Waesberghe, Jan Hein T.M. van; Mijatovic, Velja; Hompes, Peter G.A.

    2010-01-01

    Abdominal wall endometriosis (AWE) is defined as endometrial tissue that is superficial to the peritoneum. AWE is often difficult to diagnose, mimicking a broad spectrum of diseases. The aim of this study was to describe the appearance of AWE on magnetic resonance (MR) imaging. We present ten patients with AWE (12 lesions) in which MR imaging was used for diagnosis. MR imaging included T2-weighted imaging and T1-weighted imaging with fat suppression. To assess the value of diffusion-weighted imaging (DWI) in endometriosis, four patients underwent additional DWI. The apparent diffusion coefficient (ADC) was calculated using b values of 50, 400, 800 and 1,200 s/mm 2 . In most cases, the lesion was located ventral or dorsal to the aponeurosis of the rectus oblique muscle (n=6) or in the rectus abdominis (n = 5). MR of AWE lesions showed isointense or slightly hyperintense signal compared with muscle on T2-weighted images and showed isointense or slightly hyperintense signal compared with muscle on T1-weighted images with foci of high signal intensity, indicative of haemorrhage. The mean ADC value of AWE was 0.93 x 10 -3 /mm 2 /s. MR imaging seems to be useful in determining the location and depth of infiltration in surrounding tissue preoperatively. (orig.)

  11. MR imaging evaluation of subdural hematomas in child abuse

    International Nuclear Information System (INIS)

    Hay, T.C.; Rumack, C.M.; Horgan, J.G.; Hyden, P.; Krugman, R.

    1988-01-01

    MR imaging is the most accurate modality for determining the presence, number, and aging of subdural hematomas. Based on seven patients studied with CT and MR imaging, MR imaging should be the gold standard in child abuse evaluations. Since the history of child abuse is often ambiguous, MR imaging can assist in dating when the injury occurred. MR imaging in two perpendicular planes is needed, with one plane having both T1- and T2-weighted sequences. Chronic subdural hematomas on CT often have the same density as cerebrospinal fluid and may be misdiagnosed as atrophy or unrecognized. Therefore, the child may be returned into a dangerous situation and subjected to recurrent episodes of battering

  12. MR imaging of rhabdomyolysis

    International Nuclear Information System (INIS)

    Zagoria, R.J.; Karstaedt, N.; Koubek, T.D.

    1986-01-01

    The use of magnetic resonance (MR) imaging in two cases of rhabdomyolysis, one resulting from prolonged muscle compression and one from electrical burns, is described. The involved muscles were clearly demonstrated with MR. Recognition and assessment of the extent of rhabdomyolysis are important since life-threatening sequelae including severe metabolic disorders are possible. In one case, spin-echo and inversion-recovery MR imaging provided greater detail of muscle abnormalities than did 99mTc-pyrophosphate radionuclide scanning. Both cases illustrate the usefulness of MR in evaluation of skeletal muscle disorders

  13. Contribution of abdoscan using MR cholangio-pancreatography and MR urography

    International Nuclear Information System (INIS)

    Lecesne, R.; Drouillard, J.; Cisse, R.; Schiratti, M.

    1998-01-01

    MR cholangio-pancreatography (MRCP) and MR Urography (MRU) are promising recent imaging modalities. Oral magnetic particles (Abdoscan, Nycomed SA, Oslo, Norway) is an negative contrast agent eliminating signal intensity of the gastro-intestinal tract thus improvising image quality at MRCP and MRU. (author)

  14. MR imaging evaluation of plica synoviallis mediopatellaris of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Katsuyuki; Inoue, Masahiro; Murakami, Takamichi (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1992-12-01

    To evaluate the diagnostic ability of MR imaging for plica synoviallis mediopatellaris (PSM), we retrospectively reviewed the MR imaging findings of patellofemoral space in 20 knee joints of 11 patients. In all 20 knee joints, arthroscopy and MR imaging were available. MR imaging was performed with a 1.5 Tesla Magnetom (Siemens) using a round surface coil. Pulse sequences were SE (TR 600 ms/TE 26 ms), SE (TR 200 ms/TE 26,70 ms) and FLASH (TR 450 ms/TE 15 ms/FA 90deg). In six of the 20 knees with PSM proved by arthroscopy, a low intensity band was shown above the medial condyle of the femur on both T1- and T2-weighted MR images, and on FLASH images this band was shown as intermediate intensity. In the other 14 knees with no PSM observed by arthroscopy, the low intensity band was not shown on MR imaging. In all 20 knees, a similar low intensity band was shown about 1 cm cranial to the medial condyle of the femur. This should not be diagnosed as PSM. The low intensity band seen on T1- and T2-weighted MR images and its anatomical relation to the medial condyle are important in diagnosing PSM. (author).

  15. MR imaging evaluation of plica synoviallis mediopatellaris of the knee joint

    International Nuclear Information System (INIS)

    Nakanishi, Katsuyuki; Inoue, Masahiro; Murakami, Takamichi

    1992-01-01

    To evaluate the diagnostic ability of MR imaging for plica synoviallis mediopatellaris (PSM), we retrospectively reviewed the MR imaging findings of patellofemoral space in 20 knee joints of 11 patients. In all 20 knee joints, arthroscopy and MR imaging were available. MR imaging was performed with a 1.5 Tesla Magnetom (Siemens) using a round surface coil. Pulse sequences were SE (TR 600 ms/TE 26 ms), SE (TR 200 ms/TE 26,70 ms) and FLASH (TR 450 ms/TE 15 ms/FA 90deg). In six of the 20 knees with PSM proved by arthroscopy, a low intensity band was shown above the medial condyle of the femur on both T1- and T2-weighted MR images, and on FLASH images this band was shown as intermediate intensity. In the other 14 knees with no PSM observed by arthroscopy, the low intensity band was not shown on MR imaging. In all 20 knees, a similar low intensity band was shown about 1 cm cranial to the medial condyle of the femur. This should not be diagnosed as PSM. The low intensity band seen on T1- and T2-weighted MR images and its anatomical relation to the medial condyle are important in diagnosing PSM. (author)

  16. Evaluation of Nitrogen Uptake and Growth Performance of Advanced Mutant Lines MR219-4 and MR219-9 Grown Under Aerobic Conditions

    International Nuclear Information System (INIS)

    Shyful Azizi Abdul Rahman; Abdul Rahim Harun; Rusli Ibrahim; Khairuddin Abdul Rahim

    2014-01-01

    Developing a good crop production management package; drought resistance variety, effective water and nutrient management in rice production practices is crucial for global climate change adaptation. A research project under IAEA RAS5065 (Supporting Climate-Proofing Rice Production Systems (CRiPS) Based on Nuclear Applications) was conducted from 2012 to 2013, in collaboration with MARDI. Two advanced mutant lines, MR219-4 and MR219-9 were used in this research project to evaluate growth, yield potential and fertilizer uptake under different water input condition (flooded and aerobic). The advanced mutant line MR219-9 showed comparable growth, yield and nitrogen uptake under both flooded and aerobic conditions. The yield and yield components are not significantly different from the parent variety (MR219) but total N uptake was lower than MR219 regardless of water regime. The field trial showed that MR219-9 has a better total N content which is comparable to the aerobic rice variety (MRIA 1) and this indicates that this advance mutant line MR219-9 is a potential aerobic rice variety. (author)

  17. MR imaging and MR angiography in popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Atilla, S.; Akpek, S.; Yuecel, C.; Tali, E.T.; Isik, S.; Ilgit, E.T.

    1998-01-01

    Popliteal artery entrapment (PAE) syndrome is an uncommon congenital anomaly seen in young adults causing ischemic symptoms in the lower extremities. It is the result of various types of anomalous relationships between the popliteal artery and the neighboring muscular structures. The purpose of this study was to define the role of MR imaging combined with MR angiography in the diagnosis of PAE cases. Four cases with segmental occlusion and medial displacement of popliteal artery in digital subtraction angiography (DSA) examinations were diagnosed as PAE syndrome by MR imaging and MR angiography. The DSA and MRA images are compared. All of the cases showed various degrees of abnormal intercondylar insertion of the medial head of the gastrocnemius muscle. The MR images showed detailed anatomy of the region revealing the cause of the arterial entrapment. Subclassification of the cases were done and fat tissue filling the normal localization of the muscle was evaluated. The DSA and MRA images demonstrated the length and localization of the occluded segment and collateral vascular developments equally. It is concluded that angiographic evaluation alone in PAE syndrome might result in overlooking the underlying cause of the arterial occlusion, which in turn leads to unsuccessful therapy procedures such as balloon angioplasty. Magnetic resonance imaging combined with MR angiography demonstrates both the vascular anatomy and the variations in the muscular structures in the popliteal fossa successfully, and this combination seems to be the most effective way of evaluating young adults with ischemic symptoms suggesting PAE syndrome. (orig.)

  18. Accuracy of 3-Tesla MR and MR arthrography in diagnosis of meniscal retear in the post-operative knee

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas [NSI, Merritt Island, FL (United States); University of Central Florida School of Medicine, Orlando, FL (United States)

    2014-08-15

    This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy. One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy. Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear. The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely. (orig.)

  19. Von Mr Classic zu Mr Nerd: Wie Forschende soziale Medien nutzen

    Directory of Open Access Journals (Sweden)

    Doreen Siegfried

    2014-12-01

    Full Text Available Unter Wissenschaftlerinnen und Wissenschaftlern lassen sich vier Typen differenzieren, die ein signifikant unterschiedliches Verhalten in ihrer Nutzung und ihrer Einstellung gegenüber Social-Web-Anwendungen zeigen: Ms Maker, Mr Tech, Mr Classic und Mr Nerd. Grundlage für die Identifizierung dieser Social-Media-Typen ist die Auswertung von 778 Online-Fragebögen, die von Anfang September bis Mitte Oktober 2013 erhoben wurden. Erfragt wurde die Nutzung von Social-Media-Instrumenten für die tägliche Arbeit in Forschung, Lehre, Administration und Wissenschaftskommunikation. Neben Intensität und Kontext der Nutzung von Web-2.0-Diensten wurden auch die Gründe für Nutzung bzw. Nicht-Nutzung einzelner Kanäle sowie generelle Einstellungen gegenüber Social-Media-Werkzeugen erfragt. Among scientists, four types of personality can be identified whose usage and attitude towards social web applications show significant variations: Ms Maker, Mr Tech, Mr Classic and Mr Nerd. This typification is based on 778 online questionnaires received between September and October 2013. The survey sampled the usage of social media tools for daily routines in research, teaching, administrative work and scholarly communication. The survey asked questions about the intensity and the context in which Web 2.0 services are used, about the reasons for (not using certain channels, and about general attitudes towards social media tools.

  20. MR guided percutaneous laser lumbar disk hernia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko [Jikei Univ., Chiba (Japan). Kashiwa Hospital; Abe, Toshiaki

    1998-03-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  1. MR guided percutaneous laser lumbar disk hernia ablation

    International Nuclear Information System (INIS)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko; Abe, Toshiaki.

    1998-01-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  2. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    International Nuclear Information System (INIS)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der; Willems, W.J.; Bipat, Shandra

    2009-01-01

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  3. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Amsterdam (Netherlands); Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Willems, W.J. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam (NL). Department of Radiology, Academic Medical Center (Netherlands)

    2009-10-15

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  4. MR imaging of recurrent hyperparathyroidism in comparison with other imaging modalities

    International Nuclear Information System (INIS)

    Auffermann, W.; Thurnher, S.; Okerland, M.; Levin, K.; Gooding, G.W.; Clark, O.H.; Higgins, C.B.

    1987-01-01

    Thirty patients with recurrent hyperparathyroidism were evaluated with MR imaging, performed using a saddle-shaped surface coil producing 5-mm sections with T1 and T2 weighting. Twenty-six and 22 of these patients also underwent T1-201 scintigraphy and high-resolution US, respectively. MR imaging accurately localized abnormal parathyroid glands in 75% evaluated prospectively and 86% retrospectively. Scintigraphy localized 64% prospectively and 72% retrospectively. US demonstrated 57% prospectively and 67% retrospectively. MR imaging showed three of four mediastinal adenomas evaluated prospectively retrospectively. There were two false-positive studies with MR imaging, two with scintigraphy, and one with US. Thus, MR imaging was the most effective imaging modality for parathyroid localization in recurrent hyperparathyroidism

  5. Influence of MR imaging in radiation therapy of chest lymphoma

    International Nuclear Information System (INIS)

    Carlsen, S.E.; Hoppe, R.; Bergin, C.J.

    1991-01-01

    This paper evaluates the influence of MR detection of additional sites of chest lymphoma on radiation therapy. Chest MR images and CT scans of 56 patients with new or recurrent mediastinal lymphoma obtained within 1 month of each other were retrospectively reviewed. MR images included T1- and T2-weighted SE and STIR sequences. Images were assessed for pleural and extrapleural disease. Radiation portals of patients with pleural or chest wall disease were reevaluated and compared with portals originally designed with CT. MR imaging demonstrated chest wall disease in 15 patients (21 sites). Ten patients also had pleural disease (13 sites). CT identified chest wall disease in four of these patients (five sites) and pleural disease in three patients (five sites). Seven of the 15 patients with chest wall disease were treated with radiation therapy alone. Two of the seven patients had significant modification of radiation portals based on MR findings. Retrospectively, therapy would have been altered in an additional two patients in whom pleural disease was identified at MR. The increased sensitivity of MR in detecting chest wall or pleural disease has important implications for treatment planning in chest wall lymphoma

  6. MR imaging appearance of 180-360 labral tears of the shoulder

    International Nuclear Information System (INIS)

    Lindauer, Kelly R.; Major, Nancy M.; Rougier-Chapman, Duncan P.; Helms, Clyde A.

    2005-01-01

    Glenoid labral tears exceeding 180 are an uncommon entity in which characteristic clinical and MR imaging features can lead to a more accurate preoperative diagnosis. We provide a description of glenoid labral tears that exceed 180 , and their characteristic magnetic resonance imaging features. In the young, heavily muscled male athlete, the identification of multiple sites of labral pathology and isolated, extensive posterior labral injuries are features that should raise suspicion for labral tears that exceed 180 . (orig.)

  7. MR images of rupture and leakage of breast implants

    International Nuclear Information System (INIS)

    Fang Ling; Liu Pengcheng; Huang Rong; Hu Huaxin; Chen Zaizhong; Du Duanming; Liu Hanqiao; Feng Fei

    2002-01-01

    Objective: To investigate the diagnostic value of magnetic resonance imaging in detecting rupture and leakage of breast implants. Methods: Seventeen cases with breast implants were imaged by MR scanner. 1 normal silicone breast implant outside the body was scanned by MR as an consultative standard. MR images of silicone implants and polypropylene acyl amine implants were classified and analyzed. Results: In 7 cases, 12 single lumen silicone implants were intact, among them 8 were silicone gel-filled implants, 4 were physiological saline-filled implants. 2 physiological saline-filled implants ruptured, among them 1 belonged to intracapsular silicone implant rupture with subsided silicone gel capsule which presented as long T 1 signal and short T 2 signal on MR images; The other belonged to extracapsular silicone implant rapture with physiological saline granule outside breast on MR images. 20 breast implants in 10 cases were injected by polypropylene acyl amine, among them 2 breast implants were intact, 16 breast implants ruptured completely with pieces and nodes of long T 1 signal and long T 2 signal on MR images, 14 of 16 also presented polypropylene acyl amine granule outside breast; 2 breast implants splited inside with linguine sign. Conclusion: The magnetic resonance imaging can make clear the type and the seat of breast implants, the type of rupture of breast implants, and the distribution of leakage material. Therefore magnetic resonance imaging can be an effective guidance for clinical operation and can be an consultative standard for follow-up

  8. MR findings in pituitary haemosiderosis

    International Nuclear Information System (INIS)

    Ambrosetto, P.; Zucchini, S.; Cicognani, A.; Cacciari, E.

    1998-01-01

    A girl with Diamond-Blackfan syndrome and hypopituitarism was suspected of having pituitary haemosiderosis because of the clinical picture and the long history of blood transfusions. On T1-weighted MR images the pituitary exhibited a markedly hypointense anterior lobe (mimicking the empty sella), suggesting iron deposition, while on T2W MRI the low signal of the pituitary was surrounded by the high signal of the CSF. MR may be considered the examination of choice for detecting iron overload in the pituitary. (orig.)

  9. Mr Devraj Sikka

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 1984 Section: Earth & Planetary Sciences. Sikka, Mr Devraj M.Sc. (Agra). Date of birth: 1 March 1932. Date of death: 18 March 2017. Specialization: Monsoon, Tropical & Satellite Meteorology, Climate Change, Dynamics of Himalayan Glaciers and Climate Research Last known address: 40, Mausam ...

  10. The alterations of the sigmoid-rectal junction in diverticular disease of the colon revealed by MR-defecography.

    Science.gov (United States)

    Romagnoli, Francesco; Colaiacomo, Maria Chiara; De Milito, Ritanna; Modini, Claudio; Gualdi, Gianfranco; Catani, Marco

    2014-01-01

    The sigmoidorectal junction (SRJ) has been defined as an anatomical sphincter with particular physiological behavior that regulates sigmoid and rectum evacuation. Its function in clinical conditions, such as diverticular disease has been advocated. The aim of our study is to identify the SRJ and to compare the morphometric and dynamic features of the SRJ between patients with diverticular disease and healthy subjects using MR-defecography. Sixteen individuals, eight with uncomplicated diverticular disease and eight healthy subjects, were studied using MR-defecography to identify the SRJ and to compare the morphometric and dynamic features observed. In each subject studied, MR-defecography was able to identify the SRJ. This resulted in the identification of a discrete anatomical entity with a mean length of 31.23 mm, located in front of the first sacral vertebra (S1) and at a mean distance of 15.55 cm from the anal verge, with a mean wall thickness of 4.45 mm, significantly different from the sigmoid and rectal parietal thickness. The SRJ wall was significantly thicker in patients with diverticular disease than the controls (P = 0.005), showing a unique shape and behavior in dynamic sequences. Our findings support the hypothesis that SRJ plays a critical role in patients with symptomatic diverticular disease; further investigation may clarify whether specific SRJ analysis, such as MR-defecography, would predict inflammatory complications of this diffuse and heterogenic disease.

  11. MR spectroscopy in dementia; MR-Spektroskopie bei Demenz

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, T.; Gerigk, L.; Giesel, F.; Schuster, L.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung E010, Radiologie, Heidelberg (Germany)

    2010-09-15

    With an increasingly aging population we are faced with the problem of an increasing number of dementia patients. In addition to clinical, neuropsychological and laboratory procedures, MRI plays an important role in the early diagnosis of dementia. In addition to various morphological changes functional changes can also help in the diagnosis and differential diagnosis of dementia. Overall the diagnosis of dementia can be improved by using parameters from MR spectroscopy. This article focuses on MR spectroscopic changes in the physiological aging process as well as on changes in mild cognitive impairment a precursor of Alzheimer's dementia, in Alzheimer's dementia, frontotemporal dementia, vascular dementia and Lewy body dementia. (orig.) [German] Angesichts einer immer aelter werdenden Bevoelkerung sind wir mit dem Problem einer zunehmenden Zahl an Demenzerkrankungen konfrontiert. Neben klinischen, neuropsychologischen und laborchemischen Verfahren spielt die MRT zur Fruehdiagnostik einer Demenz eine wichtige Rolle. Morphologische Veraenderungen wie auch verschiedene funktionelle Verfahren helfen bei der Diagnostik und Differenzialdiagnostik einer Demenz. Insgesamt kann mittels MR-spektroskopischer Parameter die Diagnostik einer Demenz verbessert werden. In diesem Artikel soll auf MR-spektroskopische Veraenderungen im Rahmen des physiologischen Alterungsprozesses eingegangen werden. Ferner werden speziell Veraenderungen bei leichter kognitiver Beeintraechtigung, einer Vorform der Alzheimer-Demenz, bei Alzheimer-, frontotemporaler, vaskulaerer und Lewy-Koerper-Demenz eroertert. (orig.)

  12. Mtr Extracellular Electron Transfer Pathways in Fe(III)-reducing or Fe(II)-oxidizing Bacteria: A Genomic Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Liang; Rosso, Kevin M.; Zachara, John M.; Fredrickson, Jim K.

    2012-12-01

    Originally discovered in the dissimilatory metal-reducing bacterium Shewanella oneidensis MR-1 (MR-1), the Mtr (i.e., metal-reducing) pathway exists in all characterized strains of metal-reducing Shewanella. The protein components identified to date for the Mtr pathway of MR-1 include four multi-heme c-type cytochromes (c-Cyts), CymA, MtrA, MtrC and OmcA, and a porin-like, outer membrane protein MtrB. They are strategically positioned along the width of the MR-1 cell envelope to mediate electron transfer from the quinone/quinol pool in the inner-membrane to the Fe(III)-containing minerals external to the bacterial cells. A survey of microbial genomes revealed homologues of the Mtr pathway in other dissimilatory Fe(III)-reducing bacteria, including Aeromonas hydrophila, Ferrimonas balearica and Rhodoferax ferrireducens, and in the Fe(II)-oxidizing bacteria Dechloromonas aromatica RCB, Gallionella capsiferriformans ES-2 and Sideroxydans lithotrophicus ES-1. The widespread distribution of Mtr pathways in Fe(III)-reducing or Fe(II)-oxidizing bacteria emphasizes the importance of this type of extracellular electron transfer pathway in microbial redox transformation of Fe. Their distribution in these two different functional groups of bacteria also emphasizes the bi-directional nature of electron transfer reactions carried out by the Mtr pathways. The characteristics of the Mtr pathways may be shared by other pathways used by microorganisms for exchanging electrons with their extracellular environments.

  13. Evaluation of the articular cartilage of the knee joint: value of adding a T2 mapping sequence to a routine MR imaging protocol.

    Science.gov (United States)

    Kijowski, Richard; Blankenbaker, Donna G; Munoz Del Rio, Alejandro; Baer, Geoffrey S; Graf, Ben K

    2013-05-01

    To determine whether the addition of a T2 mapping sequence to a routine magnetic resonance (MR) imaging protocol could improve diagnostic performance in the detection of surgically confirmed cartilage lesions within the knee joint at 3.0 T. This prospective study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The study group consisted of 150 patients (76 male and 74 female patients with an average age of 41.2 and 41.5 years, respectively) who underwent MR imaging and arthroscopy of the knee joint. MR imaging was performed at 3.0 T by using a routine protocol with the addition of a sagittal T2 mapping sequence. Images from all MR examinations were reviewed in consensus by two radiologists before surgery to determine the presence or absence of cartilage lesions on each articular surface, first by using the routine MR protocol alone and then by using the routine MR protocol with T2 maps. Each articular surface was then evaluated at arthroscopy. Generalized estimating equation models were used to compare the sensitivity and specificity of the routine MR imaging protocol with and without T2 maps in the detection of surgically confirmed cartilage lesions. The sensitivity and specificity in the detection of 351 cartilage lesions were 74.6% and 97.8%, respectively, for the routine MR protocol alone and 88.9% and 93.1% for the routine MR protocol with T2 maps. Differences in sensitivity and specificity were statistically significant (P T2 maps to the routine MR imaging protocol significantly improved the sensitivity in the detection of 24 areas of cartilage softening (from 4.2% to 62%, P T2 mapping sequence to a routine MR protocol at 3.0 T improved sensitivity in the detection of cartilage lesions within the knee joint from 74.6% to 88.9%, with only a small reduction in specificity. The greatest improvement in sensitivity with use of the T2 maps was in the identification of early cartilage degeneration. © RSNA

  14. MR-guided pain therapy: principles and clinical applications; MR-gesteuerte Schmerztherapie: Prinzipien und klinische Applikationen

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J.; Pereira, P.L. [Diagnostische Radiologie, Eberhard-Karls-Universitaet, Tuebingen (Germany)

    2007-09-15

    X-ray fluoroscopy and computed tomography are frequently used to perform percutaneous interventions in pain therapy. The development of MR-compatible therapy needles now allows these interventions to be performed under MR imaging guidance. MR-guided interventions may be performed using most clinical MR scanners; however, systems with an open configuration are advantageous. Multiplanar pre- and intra-procedural MR imaging provides the interventionalist with essential information, such as evaluation of anatomy and pathology, as well as the planning of the procedure and monitoring of fluid distribution without the use of contrast agents. With the use of non-ionizing radiation, interventional MR imaging is especially suited for the treatment of children and young adults as well as for serial injection therapy. For spinal MR interventions, passive needle visualization is an easily achievable and reliable method. The resulting needle artifact is influenced by several factors such as the alloy of the needle, the strength of the static magnetic field, the sequence type, the spatial orientation of the therapy needle as well as the echo time and may further be optimized during the intervention by alteration of the last three factors. Fast acquisition techniques and image processing allow for continuous, near real-time MR imaging (so-called MR fluoroscopy) and interactive needle navigations, comparable to X-ray fluoroscopy and CT fluoroscopy. The purpose of this review is to illustrate and discuss general concepts of interventional MR imaging. A spectrum of interventional MR imaging procedures in spinal pain therapy is described and illustrated, including procedures such as lumbar facet joint injections, sacroiliac joint injections, lumbar spinal nerve root infiltrations and drug delivery to the lumbar sympathetic chain. (orig.)

  15. Current status of MR colonography.

    LENUS (Irish Health Repository)

    Thornton, Eavan

    2010-01-01

    The search for an acceptable colorectal cancer screening examination has led to the development of virtual colonoscopy, which includes both computed tomographic (CT) colonography and magnetic resonance (MR) colonography. As indicated by the much larger number of published studies on CT colonography than on MR colonography, multidetector CT appears to be more suitable for colorectal screening than does MR colonography, in part reflecting the ease and speed of performing CT, as well as the increased spatial resolution, decreased cost, and wider availability of CT colonography. The main advantage of MR colonography over CT colonography is that it does not use ionizing radiation, which has important implications for colorectal cancer screening. The use of dark-lumen MR colonography to screen patients for colorectal cancer as well as other abdominopelvic disease could make it more attractive than CT. With the integration of 3.0-T MR colonography, fecal tagging, and parallel imaging into research and clinical settings, new MR colonography protocols must be optimized. Future MR colonography research should address issues such as image characteristics, presence of artifacts, management of specific absorption rate, and hardware-related modifications.

  16. MR-assisted PET Motion Correction for eurological Studies in an Integrated MR-PET Scanner

    Science.gov (United States)

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B.; Michel, Christian J.; El Fakhri, Georges; Schmand, Matthias; Sorensen, A. Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MR data can be used for motion tracking. In this work, a novel data processing and rigid-body motion correction (MC) algorithm for the MR-compatible BrainPET prototype scanner is described and proof-of-principle phantom and human studies are presented. Methods To account for motion, the PET prompts and randoms coincidences as well as the sensitivity data are processed in the line or response (LOR) space according to the MR-derived motion estimates. After sinogram space rebinning, the corrected data are summed and the motion corrected PET volume is reconstructed from these sinograms and the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed and motion estimates were obtained using two high temporal resolution MR-based motion tracking techniques. Results After accounting for the physical mismatch between the two scanners, perfectly co-registered MR and PET volumes are reproducibly obtained. The MR output gates inserted in to the PET list-mode allow the temporal correlation of the two data sets within 0.2 s. The Hoffman phantom volume reconstructed processing the PET data in the LOR space was similar to the one obtained processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the novel MC algorithm. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 seconds and 20 ms, respectively. Substantially improved PET images with excellent delineation of specific brain structures were obtained after applying the MC using these MR-based estimates. Conclusion A novel MR-based MC

  17. MR imaging of the brain in neurofibromatosis

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Cohen, M.L.; Duffner, P.K.; Seidel, F.; Harwood-Nash, D.

    1986-01-01

    Fifteen children and young adults with neurofibromatosis underwent CT and MR imaging (0.5-T superconducting magnet). Seven had optic gliomas and five had other intracranial neoplasms. Before thin-section MR imaging became available, CT was superior for demonstrating the optic nerves, although MR imaging better delineated tumor spread to the optic chiasm and tract. MR imaging was superior for demonstrating other gliomatous lesions associated with neurofibromatosis. Most lesions had long T1 and T2 values and were best seen on T2-weighted images. MR imaging revealed small areas of increased signal intensity on T2-weighted images in nearly half the patients. These lesions were not apparent on CT and were usually located in the globus pallidus, but were seen in many areas of the brain, commonly in the white matter, and in the brain steam and the cerebellar peduncles. Their exact etiology is unknown. Their imaging characteristics are somewhat different from those of gray matter. They may represent hamartomas or areas of glial scarring. Differentiation from a small glioma is presently not possible on a single examination

  18. MR imaging of the pelvis

    International Nuclear Information System (INIS)

    Hricak, H.

    1987-01-01

    MR imaging, CT, and US should be viewed as complementary studies for imaging the pelvis. MR imaging is relatively expensive, not widely available, and requires special facilities. However, it is noninvasive and offers a large field-of-view, direct imaging in all three orthogonal planes and excellent soft-tissue contrast. Surgical clips, which present a problem with other imaging modalities, do not create significant MR image artifacts. Image degradation due to bowel motion can be minimized by bowel preparation and/or the administration of glucagon. The value of MR imaging of the pelvis is in staging rather than diagnosis of pelvic neoplasms. The accuracy, sensitivity, and specificity of MR imaging in staging prostate or bladder tumors exceed those of US and CT. In prostate carcinoma, MR imaging can be used to evaluate periprostatic tumor extension, especially to the bladder base, rectum, or seminal vesicles. For early transcapsular extension, however, the accuracy of transrectal US reportedly surpasses that of MR imaging. In bladder carcinoma, the value of MR imaging is in direct tumor visualization, the ability to differentiate between tumor and normal bladder wall, and the evaluation of bladder tumors located at the dome of the bladder base, where imaging in the sagittal plane is essential. In the evaluation of benign entities of the female pelvis, US remains the preferred screening modality. The use of MR imaging is reserved for cases of infertility or for planning myomectomy when knowledge of the exact number, size, and location of tumors is essential. MR imaging is useful in evaluating patients with amenorrhea or any suspected congenital anomalies. The main application of MR imaging of the female pelvis is in the staging of neoplasms, including endometrial and cervical carcinomas

  19. MR imaging of the brain: tumors

    International Nuclear Information System (INIS)

    Sartor, K.

    1999-01-01

    The radiologic modality that most likely provides the imaging information needed in a patient suspected of having a brain tumor is MR imaging. A brain tumor can be reliably ruled out if the MR examination is performed properly and experts interpret the results as negative. If there is a tumor, however, its exact location and topography must be determined. Important for therapy and prognosis are also tumor properties such as histologic type and grade, as well as effects on adjacent brain structures. Although potentially a noninvasive method of in vivo neuropathology, MR is still far from being sufficiently specific, as dissimilar lesions may look the same despite the use of refined imaging protocols. The evolution of MR imaging continues, however, making further methodologic improvement likely. Presently, advanced methods, such as diffusion- and perfusion-weighted MR imaging, functional MR imaging, neuronavigation based on MR imaging data, and the use of MR imaging during surgery (intraoperative MR imaging), influence the way patients are treated. Likewise, follow-up imaging (monitoring) of tumor patients by MR has become more effective, and experience has shown how to distinguish reactive changes from recurrent tumor. In the future, MR imaging may gain importance in the development of novel therapeutic concepts. (orig.)

  20. Histologic correlation of MR signal intensity in parathyroid adenomas

    International Nuclear Information System (INIS)

    Rumancik, W.M.; Khan, A.; Mir, R.N.; Attie, J.N.; Davis, J.E.; Ashtari, M.; Herman, P.G.

    1988-01-01

    The classic MR signal intensity pattern of parathyroid adenoma (PTA) is bright enhancement on T2-weighted images. However, variations in SI pattern have been observed in clinical practice. The purpose of this report is to describe the histologic characteristics of surgically removed PTAs as correlated with their in vivo MR imaging appearance. From May 1987 to April 1988, 51 consecutive patients with primary hyperparathyroidism were evaluated with MR imaging for preoperative localization of PTA. Surgical confirmation was obtained in all patients, with histologic evaluation available in 40. MR imaging was performed on 1.0-T system (Siemens, Magnetom) using a Helmhotz surface coil positioned at the neck. Spin-echo T1-weighted and T2-weighted multisection images were evaluated retrospectively. Signal intensities of PTA, adjacent thyroid, fat, and skeletal muscle were obtained (1) from direct region of interest determinations, and (2) visually as respective relationships of PTA to thyroid, fat, and muscle. Histologic classification was graded for (1) predominant cell type (i.e., chief or oxyphil cells), (2) acinar or solid growth pattern, (3) cystic change, (4) presence or absence of residual fat, (5) cell count per high power field, (6) heterogeneous histology, (7) gland weight, and (8) giant size (≥3 cm). The relationship of MR signal intensity to histology appears multifactorial

  1. Safety issues and updates under MR environments

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jung; Kim, Kyung Ah, E-mail: bellenina@daum.net

    2017-04-15

    Highlights: • Unexpected biological effects can occur within stronger magnetic fields. • MR safety for MR conditional items is not guaranteed beyond the tested conditions. • Updated knowledge about MR-related safety is important for a safe MR environment. - Abstract: Magnetic resonance (MR) imaging is a useful imaging tool with superior soft tissue contrast for diagnostic evaluation. The MR environments poses unique risks to patients and employees differently from ionizing radiation exposure originated from computed tomography and plain x-ray films. The technology associated with MR system has evolved continuously since its introduction in the late 1970s. MR systems have advanced with static magnetic fields, faster and stronger gradient magnetic fields and more powerful radiofrequency transmission coils. Higher field strengths of MR offers greater signal to noise capability and better spatial resolution, resulting in better visualization of anatomic detail, with a reduction in scan time. With the rapid evolution of technology associated with MR, we encounter new MR-related circumstances and unexpected dangerous conditions. A comprehensive update of our knowledge about MR safety is necessary to prevent MR-related accidents and to ensure safety for patients and staff associated with MR. This review presents an overview about MR-related safety issues and updates.

  2. Indirect MR-arthography in the fellow up of autologous osteochondral transplantation; Indirekte MR-Arthrographie zur Verlaufskontrolle nach autologer osteochondraler Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Herber, S.; Pitton, M.B.; Kalden, P.; Thelen, M.; Kreitner, K.F. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Unfallchirurgie

    2003-02-01

    Purpose: To evaluate the spectrum of findings in indirect MR-arthrography following autologous osteochondral transplantation. Patients and Methods: 10 patients with autogenous osteochondral homografts underwent indirect MR-arthrography at three, 6 and 12 months postoperatively. The MR protocol at 1.5T comprised unenhanced imagings with PD- and T{sub 2}-weighted TSE-sequences with and without fat-suppression as well as T{sub 1}-weighted fat-suppressed SE-sequences before and after iv. contrast administration and after active joint exercise. Image analysis was done by two radiologists in conference and comprised the evaluation of signal intensity (SI) and integrity of the osseous plug and the cartilage surface, as well as the presence of joint effusion or bone marrow edema. Results: At three months, all cases demonstrated a significant bone marrow edema at the recipient and donor site that corresponded to a significant enhancement after iv. contrast administration. The interface between the transplant and the normal bone showed an increased SI at three and 6 months in T{sub 2}-weighted images as well as in indirect MR-arthrography. The marrow signal normalized in most cases after 6 to 12 months, indicating vitality and healing of the transplanted osteochondral graft. The SI of the interface decreased in the same period, demonstrating the stability of the homograft at the recipient site. The osteochondral plugs were well-seated in 9/10 cases. Indirect MR-arthrography was superior to unenhanced imaging in the assessment of the cartilage surface. Cartilage coverage was complete in every case. The transplanted hyaline cartilage as well as the original cartilage showed a significant increase of the SI in indirect MR-arthrography, that did not change in follow up studies. There were no pathological alterations of signal and thickness alterations of the transplanted cartilage in follow up investigations. Conclusion: Indirect MR-arthrography is a useful diagnostic tool

  3. MR findings in iliotibial band syndrome

    International Nuclear Information System (INIS)

    Nishimura, G.; Yamato, M.; Tamai, K.; Takahashi, J.; Uetani, M.

    1997-01-01

    Objective. To elucidate the MR findings in iliotibial band (ITB) syndrome. Design and patients. The subjects comprised four patients (five knees) with lateral knee pain: two athletes and two non-athletes. One non-athlete was engaged in work requiring repetitive knee movement, and the other suffered from Cushing syndrome and had bilateral abnormalities. All patients were suspected of having a lateral meniscal tear prior to MR examination, but physical examination following provisional MR diagnosis warranted the final diagnosis. MR studies included fast spin echo sagittal imaging, fat-saturated fast spin echo proton density coronal imaging, and T2* radial imaging. Twelve normal volunteers were examined. Results and conclusion. Fat-saturated coronal imaging demonstrated an ill-defined, high-intensity area deep to the ITB. T2* radial imaging showed an identical, but less conspicuous, abnormality. The MR finding suggested soft tissue inflammation and/or edema rather than focal fluid collection in the bursae. The signal alteration predominated in the region beneath the posterior fibers of the ITB, thus supporting the current opinion that the posterior fibers of the ITB are tighter against the lateral femoral epicondyle than the anterior fibers. The ITB itself did not show any signal alteration or increased thickness. (orig.). With 4 figs., 1 tab

  4. The value of adding conventional MR imaging to MR cholangiopancreatography in differentiation of benign and malignant causes of postoperative disorders

    International Nuclear Information System (INIS)

    Sun Changjin; Zhou Xiangping; Song Bin; Chen Xian; Liu Rongbo; Yan Zhihan; Xiong Yan

    2003-01-01

    Objective: To determine the value of conventional T 1 - and T 2 -weighted images and gadolinium-enhanced magnetic resonance (MR) images as a supplement to MR cholangiopancreatography (MRCP) in differentiation of benign from malignant causes of postoperative disorders in the biliary ductal system. Methods: Sixty-one patients with postoperative disorders in the biliary ductal system with proved causes underwent MRCP, conventional T 1 - and less heavily T 2 -weighted images, as well as gadolinium-enhanced images. Two radiologists independently reviewed MRCP images alone, MRCP plus nonenhanced T 1 - and T 2 -weighted images, and MRCP plus nonenhanced and gadolinium-enhanced images. The results of MR findings were compared with that of the surgical findings and the pathology. Results: For the diagnosis of postoperative disorders only with MRCP images, the sensitivity, specificity, and accuracy was 42.1%, 80.9% and 68.9% for radiologist 1 and 47.4%, 85.7%, and 73.8% for radiologist 2, respectively. When MRCP images were interpreted with T 1 - and T 2 -weighted images, the sensitivity, specificity, and accuracy was 78.9%, 92.9% and 88.5% for radiologist 1 and, 78.9%, 95.2%, and 90.2% for radiologist 2, respectively. When MRCP images were combined with both nonenhanced T 1 - and T 2 -weighted images and enhanced MR images, the sensitivity, specificity, and accuracy was 84.2%, 95.2% and 91.8% for radiologist 1 and 84.2%, 97.6%, and 93.4% for radiologist 2, respectively. There was no significant difference between the 2 readers (P>0.05). For differentiation of benign from malignant causes of postoperative disorders, the area under the receiver operating characteristic curve (Az) was significantly larger for MRCP images interpreted with T 1 - and T 2 weighted images (0.907 for reader 1, 0.920 for reader 2) than for MRCP images alone (0.682 reader 1, 0.714 for reader 2) (P 1 - and T 2 -weighted images did not significantly increase the accuracy (Az = 0.948 for reader 1, 0

  5. MR imaging findings in patients with mesial temporal sclerosis

    International Nuclear Information System (INIS)

    Zimmerman, R.A.; Sperling, M.; Bilaniuk, L.T.; O'Connor, M.; Hackney, D.B.; Grossman, R.I.; Goldberg, H.I.; Gonatas, N.

    1987-01-01

    Eleven patients (aged 19-37) with temporal lobe epilepsy were evaluated by 1.5-T MR imaging. The MR imaging followed a negative CT examination. All patients underwent ictal and interictal, depth electrode EEG recording, carotid arteriography with amytol test, neuropsychological testing, subsequent unilateral temporal lobectomy, and pathologic correlation. MR images were retrospectively reviewed and correlated. MR images in ten patients showed a small temporal lobe on the abnormal side. Abnormal signal intensity was not found within the temporal lobe despite the use of coronal and axial long TR (2,500 msec) and short and long TE(30 and 80 msec) studies

  6. Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases

    NARCIS (Netherlands)

    Lam, Mie K; Huisman, Merel; Nijenhuis, Robbert J; van den Bosch, Maurice; Viergever, Max A; Moonen, Chrit Tw; Bartels, LW

    2015-01-01

    BACKGROUND: Magnetic resonance (MR)-guided high-intensity focused ultrasound has emerged as a clinical option for palliative treatment of painful bone metastases, with MR thermometry (MRT) used for treatment monitoring. In this study, the general image quality of the MRT was assessed in terms of

  7. Motion correction in simultaneous PET/MR brain imaging using sparsely sampled MR navigators

    DEFF Research Database (Denmark)

    Keller, Sune H; Hansen, Casper; Hansen, Christian

    2015-01-01

    BACKGROUND: We present a study performing motion correction (MC) of PET using MR navigators sampled between other protocolled MR sequences during simultaneous PET/MR brain scanning with the purpose of evaluating its clinical feasibility and the potential improvement of image quality. FINDINGS......: Twenty-nine human subjects had a 30-min [(11)C]-PiB PET scan with simultaneous MR including 3D navigators sampled at six time points, which were used to correct the PET image for rigid head motion. Five subjects with motion greater than 4 mm were reconstructed into six frames (one for each navigator...

  8. MR imaging manifestations of skin tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong-hyon; Kim, Jee Young [The Catholic University of Korea, Department of Diagnostic Radiology, St. Vincent' s Hospital, Suwon, Gyeonggi-do (Korea); Chun, Kyung Ah [The Catholic University of Korea, Department of Diagnostic Radiology, Uijeongbu St. Mary Hospital, Uijeongbu, Gyeonggi-do (Korea); Jee, Won-Hee [The Catholic University of Korea, Department of Diagnostic Radiology, Kangnam St. Mary' s Hospital, Seoul (Korea); Sung, Mi-Sook [The Catholic University of Korea, Department of Diagnostic Radiology, Holy family Hospital, Bucheon, Gyeonggi-do (Korea)

    2008-11-15

    In this study, we evaluated MR imaging findings of skin tumors and categorized them into four types: (1) discrete mass lesions of the dermis and epidermis, (2) mass lesions of the subcutis with or without abutment to the skin, (3) diffuse or localized skin thickening without a true mass, and (4) a skin mass with bone destruction. The categorization of MR images may be useful in the differential diagnosis of skin tumors. (orig.)

  9. Accuracy and interobserver agreement between MR-non-expert radiologists and MR-experts in reading MRI for suspected appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Leeuwenburgh, Marjolein M.N., E-mail: m.m.leeuwenburgh@amc.uva.nl [Department of Surgery, Academic Medical Center, University of Amsterdam (Netherlands); Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands); Wiarda, Bart M. [Department of Radiology, Alkmaar Medical Center, Alkmaar (Netherlands); Jensch, Sebastiaan [Department of Radiology, Sint Lucas Andreas Hospital, Amsterdam (Netherlands); Wouter van Es, H. [Department of Radiology, Sint Antonius Hospital, Nieuwegein (Netherlands); Stockmann, Hein B.A.C. [Department of Surgery, Kennemer Gasthuis, Haarlem (Netherlands); Gratama, Jan Willem C. [Department of Radiology, Gelre Hospitals, Apeldoorn (Netherlands); Cobben, Lodewijk P.J. [Department of Radiology, Haaglanden Medical Center, Leidschendam (Netherlands); Bossuyt, Patrick M.M. [Department of Clinical Epidemiology, Academic Medical Center, University of Amsterdam (Netherlands); Boermeester, Marja A. [Department of Surgery, Academic Medical Center, University of Amsterdam (Netherlands); Stoker, Jaap [Department of Radiology, Academic Medical Center, University of Amsterdam (Netherlands)

    2014-01-15

    Objective: To compare accuracy and interobserver agreement between radiologists with limited experience in the evaluation of abdominal MRI (non-experts), and radiologists with longer MR reading experience (experts), in reading MRI in patients with suspected appendicitis. Methods: MR imaging was performed in 223 adult patients with suspected appendicitis and read independently by two members of a team of eight MR-inexperienced radiologists, who were trained with 100 MR examinations previous to this study (non-expert reading). Expert reading was performed by two radiologists with a larger abdominal MR experience (>500 examinations) in consensus. A final diagnosis was assigned after three months based on all available information, except MRI findings. We estimated MRI sensitivity and specificity for appendicitis and for all urgent diagnoses separately. Interobserver agreement was evaluated using kappa statistics. Results: Urgent diagnoses were assigned to 147 of 223 patients; 117 had appendicitis. Sensitivity for appendicitis was 0.89 by MR-non-expert radiologists and 0.97 in MR-expert reading (p = 0.01). Specificity was 0.83 for MR-non-experts versus 0.93 for MR-expert reading (p = 0.002). MR-experts and MR-non-experts agreed on appendicitis in 89% of cases (kappa 0.78). Accuracy in detecting urgent diagnoses was significantly lower in MR-non-experts compared to MR-expert reading: sensitivity 0.84 versus 0.95 (p < 0.001) and specificity 0.71 versus 0.82 (p = 0.03), respectively. Agreement on urgent diagnoses was 83% (kappa 0.63). Conclusion: MR-non-experts have sufficient sensitivity in reading MRI in patients with suspected appendicitis, with good agreement with MR-expert reading, but accuracy of MR-expert reading was higher.

  10. Accuracy and interobserver agreement between MR-non-expert radiologists and MR-experts in reading MRI for suspected appendicitis

    International Nuclear Information System (INIS)

    Leeuwenburgh, Marjolein M.N.; Wiarda, Bart M.; Jensch, Sebastiaan; Wouter van Es, H.; Stockmann, Hein B.A.C.; Gratama, Jan Willem C.; Cobben, Lodewijk P.J.; Bossuyt, Patrick M.M.; Boermeester, Marja A.; Stoker, Jaap

    2014-01-01

    Objective: To compare accuracy and interobserver agreement between radiologists with limited experience in the evaluation of abdominal MRI (non-experts), and radiologists with longer MR reading experience (experts), in reading MRI in patients with suspected appendicitis. Methods: MR imaging was performed in 223 adult patients with suspected appendicitis and read independently by two members of a team of eight MR-inexperienced radiologists, who were trained with 100 MR examinations previous to this study (non-expert reading). Expert reading was performed by two radiologists with a larger abdominal MR experience (>500 examinations) in consensus. A final diagnosis was assigned after three months based on all available information, except MRI findings. We estimated MRI sensitivity and specificity for appendicitis and for all urgent diagnoses separately. Interobserver agreement was evaluated using kappa statistics. Results: Urgent diagnoses were assigned to 147 of 223 patients; 117 had appendicitis. Sensitivity for appendicitis was 0.89 by MR-non-expert radiologists and 0.97 in MR-expert reading (p = 0.01). Specificity was 0.83 for MR-non-experts versus 0.93 for MR-expert reading (p = 0.002). MR-experts and MR-non-experts agreed on appendicitis in 89% of cases (kappa 0.78). Accuracy in detecting urgent diagnoses was significantly lower in MR-non-experts compared to MR-expert reading: sensitivity 0.84 versus 0.95 (p < 0.001) and specificity 0.71 versus 0.82 (p = 0.03), respectively. Agreement on urgent diagnoses was 83% (kappa 0.63). Conclusion: MR-non-experts have sufficient sensitivity in reading MRI in patients with suspected appendicitis, with good agreement with MR-expert reading, but accuracy of MR-expert reading was higher

  11. PET/MR Imaging in Gynecologic Oncology.

    Science.gov (United States)

    Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina

    2017-08-01

    MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Appearance of abdominal wall endometriosis on MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Busard, Milou P.H.; Kuijk, Cees van; Waesberghe, Jan Hein T.M. van [VU Medical Center, Department of Radiology, Endometriosis Center VUMC, Amsterdam (Netherlands); Mijatovic, Velja; Hompes, Peter G.A. [VU Medical Center, Department of Gynecology, Endometriosis Center, Amsterdam (Netherlands)

    2010-05-15

    Abdominal wall endometriosis (AWE) is defined as endometrial tissue that is superficial to the peritoneum. AWE is often difficult to diagnose, mimicking a broad spectrum of diseases. The aim of this study was to describe the appearance of AWE on magnetic resonance (MR) imaging. We present ten patients with AWE (12 lesions) in which MR imaging was used for diagnosis. MR imaging included T2-weighted imaging and T1-weighted imaging with fat suppression. To assess the value of diffusion-weighted imaging (DWI) in endometriosis, four patients underwent additional DWI. The apparent diffusion coefficient (ADC) was calculated using b values of 50, 400, 800 and 1,200 s/mm{sup 2}. In most cases, the lesion was located ventral or dorsal to the aponeurosis of the rectus oblique muscle (n=6) or in the rectus abdominis (n = 5). MR of AWE lesions showed isointense or slightly hyperintense signal compared with muscle on T2-weighted images and showed isointense or slightly hyperintense signal compared with muscle on T1-weighted images with foci of high signal intensity, indicative of haemorrhage. The mean ADC value of AWE was 0.93 x 10{sup -3}/mm{sup 2}/s. MR imaging seems to be useful in determining the location and depth of infiltration in surrounding tissue preoperatively. (orig.)

  13. MR imaging in chronic epicondylitis humeri radialis at 1.0 T: is Gd-DTPA administration useful?; MRT bei chronischer Epicondylitis humeri radialis an einem 1,0 T-Geraet - Kontrastmittelgabe notwendig?

    Energy Technology Data Exchange (ETDEWEB)

    Herber, S.; Kalden, P.; Kreitner, K.-F.; Thelen, M. [Tuebingen Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Riedel, C.; Rompe, J.D. [Klinik und Poliklinik fuer Orthopaedie Johannes-Gutenberg-Univ. Mainz (Germany)

    2001-05-01

    Purpose: Evaluation of the diagnostic value and confidence of contrast-enhanced MR imaging in patients with lateral epicondylitis in comparison to clinical diagnosis. Material and Methods: 42 consecutive patients with clinically proven chronic lateral epicondylitis and 10 ellbow joints of healthy controls have been examined on a 1.0 T MR-unit. Criteria for inclusion in the prospective study were: persistant pain and a failed conservative therapy. The MR protocol included STIR sequence, a native, T{sub 2}-weighted, fat-supressed TSE sequence, and a flash-2-D sequence. Also, fat-supressed, T{sub 1}-weighted SE sequences before and after administration of Gd-DTPA contrast media have been recovded. Results: In 39/42 patients the STIR sequence showed an increased SI of the common extensor tendom. Increased MR signal of the lateral collateral ligament combined with a thickening and a partial rupture or a full thickness tear have been observed in 15/42 cases. A bone marrow edema at the lateral epicondylus was noticed in 6 of the studied patients and a joint effusion in 18/42 patients. After administration of contrast media we noticed an average increase of SI by about 150%. However, enhanced MR imaging did not provide additional information. Conclusion: In MR imaging of chronic epicondylitis administration of gadolinium-DTPA does not provide additional information. (orig.) [German] Zielsetzung: Evaluation der Wertigkeit der Gadolinium-DTPA-Gabe in der MR-Diagnostik der chronischen Epicondylitis humeri radialis im Vergleich zur klinischen Befunderhebung. Material und Methoden: 42 konsekutive Patienten mit einer klinisch diagnostizierten chronischen Epicondylitis humeri radialis sowie 10 Ellenbogengelenke bei 5 Probanden wurden bei 1,0 T prospektiv untersucht. Einschlusskriterium war eine persistierende Schmerzsymptomatik ueber mehr als ein halbes Jahr. Das MR-Protokoll beinhaltete neben einer STIR-Sequenz eine native T{sub 2}-gewichtete TSE-Sequenz mit Fettsupression sowie

  14. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer.

    Science.gov (United States)

    Fischer, U; Kopka, L; Brinck, U; Korabiowska, M; Schauer, A; Grabbe, E

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1, c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes.

  15. Subtraction and dynamic MR images of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Yoshitaka; Aoki, Manabu; Harada, Junta (Jikei Univ., Tokyo (Japan). School of Medicine)

    1993-04-01

    The purpose of this study was to evaluate the diagnostic effectiveness of subtraction and dynamic MR imaging in patients with breast masses. In 23 breast cancers and six fibroadenomas, spin echo T1 images were obtained at 0.2 Tesla before and every minute after intravenous injection of Gd-DTPA (0.1 or 0.2 mmol/kg). Subtraction images were obtained sequentially on the CRT monitor. All breast masses were enhanced after gadolinium and stood out as bright lesions on subtraction images. The tumor margin and its extension were more precisely evaluated on subtraction MR images than on conventional postcontrast MR images. Breast cancer showed a characteristic time-intensity curve with an early peak, in contrast to fibroadenoma, which showed a gradual increase in signal intensity. Subtraction MR imaging is a simple method for the evaluation of breast masses, and further, the time-intensity curve obtained by dynamic study is helpful in the differential diagnosis of lesions. (author).

  16. A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer

    International Nuclear Information System (INIS)

    Dregely, Isabel; Lanz, Titus; Mueller, Matthias F.; Metz, Stephan; Kuschan, Marika; Nimbalkar, Manoj; Ziegler, Sibylle I.; Nekolla, Stephan G.; Schwaiger, Markus; Bundschuh, Ralph A.; Haase, Axel

    2015-01-01

    To implement and evaluate a dedicated receiver array coil for simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging in breast cancer. A 16-channel receiver coil design was optimized for simultaneous PET/MR imaging. To assess MR performance, the signal-to-noise ratio, parallel imaging capability and image quality was evaluated in phantoms, volunteers and patients and compared to clinical standard protocols. For PET evaluation, quantitative 18 F-FDG PET images of phantoms and seven patients (14 lesions) were compared to images without the coil. In PET image reconstruction, a CT-based template of the coil was combined with the MR-acquired attenuation correction (AC) map of the phantom/patient. MR image quality was comparable to clinical MR-only examinations. PET evaluation in phantoms showed regionally varying underestimation of the standardised uptake value (SUV; mean 22 %) due to attenuation caused by the coil. This was improved by implementing the CT-based coil template in the AC (<2 % SUV underestimation). Patient data indicated that including the coil in the AC increased the SUV values in the lesions (21 ± 9 %). Using a dedicated PET/MR breast coil, state-of-the-art MRI was possible. In PET, accurate quantification and image homogeneity could be achieved if a CT-template of this coil was included in the AC for PET image reconstruction. (orig.)

  17. Molecular MR Imaging for Visualizing ICAM-1 Expression in the Inflamed Synovium of Collagen-Induced Arthritic Mice

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Il [Gyeongsang National University, Jinju (Korea, Republic of); Lee, Sang Yong; Jang, Kyu Yun; Yoo, Wan Hee [Chonbuk National University, Jeonju (Korea, Republic of); Yoon, Kwon Ha [Wonkwang University School of Medicine, Iksan (Korea, Republic of); Choi, Kyu Sil [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Sang Hyon; Choi, Tae Hyun [Dongsan Medical Center, Keimyung University, Daegu (Korea, Republic of); Park, Jin Gyoon [Chonnam National University Medical School, Gwangju (Korea, Republic of)

    2009-10-15

    To determine the utility of intercellular adhesion molecule (ICAM)-1 antibody-conjugated gadolinium diethylenetriaminepentaacetic acid (Gd-DTPAanti- ICAM-1) as a targeted contrast agent for the molecular magnetic resonance imaging (MRI) in collagen-induced arthritis (CIA). Three groups of mice were used: non-arthritic normal, CIA mice in both the early inflammatory and chronic destructive phases. The MR images of knee joints were obtained before and after injection of Gd-DTPA-anti- ICAM-1, Gd-DTPA, and Gd-DTPA-Immunoglobulin G (Ig G) and were analyzed quantitatively. The patterns of enhancement on the MR images were compared with the histological and immunohistochemical ICAM-1 staining. The images obtained after injection of Gd-DTPA-anti-ICAM-1 displayed gradually increasing signal enhancement from the moment following injection (mean {+-} standard deviation [SD]: 424.3 {+-} 35.2, n = 3) to 24 hours (532 {+-} 11.3), rather than on pre-enhanced images (293 {+-} 37.6) in the early inflammatory phase of CIA mice. However, signal enhancement by Gd-DTPA and Gd- DTPA-IgG disappeared after 80 minutes and 24 hours, respectively. In addition, no significant enhancement was seen in the chronic destructive phase of CIA mice, even though they also showed inflammatory changes on T2-weighted MR images. ICAM-1 expression was demonstrated in the endothelium and proliferating synovium of the early inflammatory phase of CIA mice, but not in the chronic destructive phase. Molecular MRI with Gd-DTPA-anti-ICAM-1 displays specific images targeted to ICAM-1 that is expressed in the inflamed synovium of CIA. This novel tool may be useful for the early diagnosis and differentiation of the various stages of rheumatoid arthritis.

  18. Adaptation of antenna profiles for control of MR guided hyperthermia (HT) in a hybrid MR-HT system

    International Nuclear Information System (INIS)

    Weihrauch, Mirko; Wust, Peter; Weiser, Martin; Nadobny, Jacek; Eisenhardt, Steffen; Budach, Volker; Gellermann, Johanna

    2007-01-01

    A combined numerical-experimental iterative procedure, based on the Gauss-Newton algorithm, has been developed for control of magnetic resonance (MR)-guided hyperthermia (HT) applications in a hybrid MR-HT system BSD 2000 3D-MRI. In this MR-HT system, composed of a 3-D HT applicator Sigma-Eye placed inside a tunnel-type MR tomograph Siemens MAGNETOM Symphony (1.5 T), the temperature rise due to the HT radiation can be measured on-line in three dimensions by use of the proton resonance frequency shift (PRFS) method. The basic idea of our iterative procedure is the improvement of the system's characterization by a step-by-step modification of the theoretical HT antenna profiles (electric fields radiated by single antennas). The adaptation of antenna profiles is efficient if the initial estimates are radiation fields calculated from a good a priori electromagnetic model. Throughout the iterative procedure, the calculated antenna fields (FDTD) are step-by-step modified by comparing the calculated and experimental data, the latter obtained using the PRFS method. The procedure has been experimentally tested on homogeneous and inhomogeneous phantoms. It is shown that only few comparison steps are necessary for obtaining a dramatic improvement of the general predictability and quality of the specific absorption rate (SAR) inside the MR-HT hybrid system

  19. Only MR can safely exclude patients from arthroscopy

    International Nuclear Information System (INIS)

    Vincken, Patrice W.J.; Braak, Bert P.M. ter; Erkel, Arian R. van; Bloem, Johan L.; Bloem, Rolf M.; Luijt, Peter A. van; Coene, L.N.J.E.M.; Lange, Sam de

    2009-01-01

    The aim of this study was to determine in patients with subacute knee complaints and normal standardized physical examination the fraction of magnetic resonance imaging (MRI) studies showing arthroscopically treatable intra-articular pathology. There were 290 consecutive patients (between 16 and 45 years) with at least 4 weeks of knee complaints and low clinical suspicion of intra-articular pathology based on physical exam. Two hundred seventy-four patients were included. Sixteen patients with prior knee surgery, rheumatic arthritis, or severe osteoarthritis were excluded. MRI was used to assign patients to group 1 (treatable abnormalities) or group 2 (normal or no treatable findings), depending on whether MR demonstrated treatable pathology. Arthroscopy was performed in group 1 patients. If symptoms persisted for 3 months in group 2 patients, cross over to arthroscopy was allowed. MR showed treatable pathology in 73 patients (26.6%). Arthroscopy was performed in 64 patients of 73 patients (group 1). In 52 patients (81.3%, 95% confidence interval (CI) 71.4-91.1%), arthroscopy was therapeutic. Of the 13 arthroscopies (6.5%) in group 2, four were therapeutic (30.8%, 95% CI 1.7-59.8). The highest fraction of MR studies showing treatable pathology was found in males, aged over 30 years, with a history of effusion (54.5%, six of 11 patients). Authors believe that the negative predictive value of clinical assessment in patients with subacute knee complaints is too low to exclude these patients from MR. MR should at least be considered in male patients aged 30 years and over with a history of effusion. (orig.)

  20. Only MR can safely exclude patients from arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Vincken, Patrice W.J.; Braak, Bert P.M. ter; Erkel, Arian R. van; Bloem, Johan L. [Leiden University Medical Center, Department of Radiology, P.O. Box 9600, Leiden (Netherlands); Bloem, Rolf M. [Leiden University Medical Center, Department of Orthopedic Surgery, Leiden (Netherlands); Reinier de Graaf Gasthuis, Department of Orthopedic Surgery, Delft (Netherlands); Luijt, Peter A. van [Leiden University Medical Center, Department of Traumatology, Leiden (Netherlands); Coene, L.N.J.E.M. [HAGA Hospital, Department of Orthopaedic Surgery, The Hague (Netherlands); Lange, Sam de [Medical Center Haaglanden, Department of Orthopedic Surgery, The Hague (Netherlands)

    2009-10-15

    The aim of this study was to determine in patients with subacute knee complaints and normal standardized physical examination the fraction of magnetic resonance imaging (MRI) studies showing arthroscopically treatable intra-articular pathology. There were 290 consecutive patients (between 16 and 45 years) with at least 4 weeks of knee complaints and low clinical suspicion of intra-articular pathology based on physical exam. Two hundred seventy-four patients were included. Sixteen patients with prior knee surgery, rheumatic arthritis, or severe osteoarthritis were excluded. MRI was used to assign patients to group 1 (treatable abnormalities) or group 2 (normal or no treatable findings), depending on whether MR demonstrated treatable pathology. Arthroscopy was performed in group 1 patients. If symptoms persisted for 3 months in group 2 patients, cross over to arthroscopy was allowed. MR showed treatable pathology in 73 patients (26.6%). Arthroscopy was performed in 64 patients of 73 patients (group 1). In 52 patients (81.3%, 95% confidence interval (CI) 71.4-91.1%), arthroscopy was therapeutic. Of the 13 arthroscopies (6.5%) in group 2, four were therapeutic (30.8%, 95% CI 1.7-59.8). The highest fraction of MR studies showing treatable pathology was found in males, aged over 30 years, with a history of effusion (54.5%, six of 11 patients). Authors believe that the negative predictive value of clinical assessment in patients with subacute knee complaints is too low to exclude these patients from MR. MR should at least be considered in male patients aged 30 years and over with a history of effusion. (orig.)