WorldWideScience

Sample records for one-piece implant-supported superstructures

  1. Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks.

    Tiossi, R; Falcão-Filho, H; Aguiar Júnior, F A; Rodrigues, R C; Mattos, M da G; Ribeiro, R F

    2010-05-01

    This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27.57 +/- 5.06 microm) than other groups (I: 11.19 +/- 2.54 microm, III: 12.88 +/- 2.93 microm, IV: 13.77 +/- 1.51 microm) (P screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58.66 +/- 14.30 microm) was significantly different from cp Ti group after diagonal section (IV: 27.51 +/- 8.28 microm) (P 0.05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

  2. One piece reactor removal

    Chia, Wei-Min; Wang, Song-Feng

    1993-01-01

    The strategy of Taiwan Research Reactor Renewal plan is to remove the old reactor block with One Piece Reactor Removal (OPRR) method for installing a new research reactor in original building. In this paper, the engineering design of each transportation works including the work method, the major equipments, the design policy and design criteria is described and discussed. In addition, to ensure the reactor block is safety transported for storage and to guarantee the integrity of reactor base mat is maintained for new reactor, operation safety is drawn special attention, particularly under seismic condition, to warrant safe operation of OPRR. ALARA principle and Below Regulatory Concern (BRC) practice were also incorporated in the planning to minimize the collective dose and the total amount of radioactive wastes. All these activities are introduced in this paper. (J.P.N.)

  3. The role of superstructure material on the stress distribution in mandibular full-arch implant-supported fixed dentures. A CT-based 3D-FEA.

    Ferreira, Mayara Barbosa; Barão, Valentim Adelino; Faverani, Leonardo Perez; Hipólito, Ana Carolina; Assunção, Wirley Gonçalves

    2014-02-01

    This study evaluated the stress distribution in mandibular full-arch implant-supported fixed dentures with different veneering and metallic infrastructure materials, using three-dimensional finite element analysis. Ten models were obtained from an edentulous human mandible with a complete denture fixed by four implants. Acrylic resin (RES) and porcelain (POR) teeth were associated with infrastructures of titanium (Ti), gold (Au), silver-palladium (AgPd), chrome-cobalt (CoCr) and nickel-chrome (NiCr). A 100-N oblique was applied. The von Mises (σvM) and maximum (σmax) and minimum (σmin) principal stresses were obtained. The RES-AgPd group showed the lowest σvM values, while the RES-Ni-Cr group showed the highest. In the bone tissue, the RES-Au group was the only one that showed different σmax values with a 12% increase in comparison to the other groups which had similar stress values. In the implants, the groups with Ti, Au and AgPd infrastructures, either with porcelain or resin teeth, showed σvM values similar and lower in comparison to the groups with CoCr and NiCr infrastructures. The tooth veneering material influenced the stress values in metallic infrastructures, in which the acrylic resin had the highest values. The veneering and infrastructure materials have influence on stress values of implant-supported dentures, except for the peri-implant bone tissue. © 2013.

  4. One-Piece Faraday Generator: A Paradoxical Experiment from 1851

    Crooks, M. J.; And Others

    1978-01-01

    Describes an experiment based on Faraday's one-piece generator, where the rotating disk is replaced by a cylindrical permanent magnet. Explains the apparent paradox that an observer in an inertial frame could measure his absolute velocity. (GA)

  5. One Piece Orbitozygomatic Approach Based on the Sphenoid Ridge Keyhole

    Spiriev, Toma; Poulsgaard, Lars; Fugleholm, Kåre

    2016-01-01

    The one-piece orbitozygomatic (OZ) approach is traditionally based on the McCarty keyhole. Here, we present the use of the sphenoid ridge keyhole and its possible advantages as a keyhole for the one-piece OZ approach. Using transillumination technique the osteology of the sphenoid ridge...... was examined on 20 anatomical dry skull specimens. The results were applied to one-piece OZ approaches performed on freshly frozen cadaver heads. We defined the center of the sphenoid ridge keyhole as a superficial projection on the lateral skull surface of the most anterior and thickest part of the sphenoid...... ridge. It was located 22 mm (standard deviation [SD], 0.22 mm) from the superior temporal line; 10.7 mm (SD, 0.08 mm) posterior and 7.1 mm (SD, 0.22 mm) inferior to the frontozygomatic suture. The sphenoid ridge burr hole provides exposure of frontal, temporal dura as well as periorbita, which...

  6. One-Piece Implant-Retained Mandibular Overdentures By Pre-Fabricated Titanium Telescopic Attachments and Frictional Varnish: A Two-Year Prospective Study.

    Nik, Shahram Namjoy; Nejatian, Touraj

    2016-12-01

    Clinical efficiency of one-piece screw-type implants with telescopic were attachments evaluated in this study. Twenty-four patients received a mandibular implant-supported overdenture and maxillary complete denture. Ninety-six one-piece implants were inserted in the inter-foraminal area. Implants were immediately loaded with an implant-retained overdenture and telescopic attachments which had frictional retention elements. There was 0.25±0.24 mm, 0.32±0.25 mm, 0.43±0.30 mm, 0.61±0.30 mm and of bone resorption after 3, 6, 12 and 24 months, respectively. The need to activate the frictional retention was the most common complication. Treatment outcomes for prefabricated telescopic retained overdentures on one-piece implants are similar to that obtained in cases of delayed loading. Copyright© 2016 Dennis Barber Ltd.

  7. Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method

    Falcão-Filho, Hilmo Barreto Leite; de Aguiar, Fábio Afrânio; Rodrigues, Renata Cristina Silveira; de Mattos, Maria da Gloria Chiarello; Ribeiro, Ricardo Faria

    2012-01-01

    PURPOSE Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS The results on the tightened side were significantly lower in Group C (6.43 ± 3.24 µm) when compared to Groups A (16.50 ± 7.55 µm) and B (16.27 ± 1.71 µm) (Plaser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66±14.30 µm; Group B, 39.48±12.03 µm; Group C, 23.13±8.24 µm) (P<.05). CONCLUSION Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks. PMID:22737313

  8. Implant Gigi One-Piece vs Two-Pieces dalam Praktek Sehari-Hari

    Dian Lestari Kurnia

    2014-12-01

    prosedur bedah dan prosedur prostetik lebih sederhana. Desain ini juga meniadakan celah mikro pada perbatasan implant dan abutment. Desain implant gigi one-piece memiliki keterbatasan pada pilihan prosedur prostetik apabila dibandingkan dengan desain implant gigi two-pieces.   One-Piece Versus Two-pieces Tooth Implant In Daily Practice. Implant had been a gold standard to replace missing tooth. However, implant marketed today was considered complex, and needs a second surgery. Complications may occur such as screw loosening or fracture and the presence of micro gap at implant-abutment-junction that is found causing fixture failure. The one-piece-implant design may offer some advantages. Purpose: this paper was aimed to discuss the pros and cons of one-piece-implants and two-piece-implants. Case 1 A 43-year-old woman came to place an implant on #16. The available bone height was 5 mm. A trans alveolar sinus lift procedure was performed with 0,5 cc allograft. A 12 mm one-piece-implant was inserted. Case 2 A 24-year-old woman came to place an implant on #46. The available bone height was 12 mm and a 10 mm two-piece-implant was inserted. Discussion: One-piece-implant offers some advantage. It needs no second surgery, easier placement protocol, and more natural prosthetic procedures. The design is preventing the failure in implant-abutment-junction failure. The absence of micro gap in one-piece-implant seems superior in preventing crestal bone resorption. However, the prosthetic option was limited in one-piece-implant. Two-piece-implant offers more choices in prosthetic abutment. Conclusion: One-piece-implant was easier and provide simple protocol with limited choice on prosthetic.

  9. Fit Analysis of Different Framework Fabrication Techniques for Implant-Supported Partial Prostheses.

    Spazzin, Aloísio Oro; Bacchi, Atais; Trevisani, Alexandre; Farina, Ana Paula; Dos Santos, Mateus Bertolini

    2016-01-01

    This study evaluated the vertical misfit of implant-supported frameworks made using different techniques to obtain passive fit. Thirty three-unit fixed partial dentures were fabricated in cobalt-chromium alloy (n = 10) using three fabrication methods: one-piece casting, framework cemented on prepared abutments, and laser welding. The vertical misfit between the frameworks and the abutments was evaluated with an optical microscope using the single-screw test. Data were analyzed using one-way analysis of variance and Tukey test (α = .05). The one-piece casted frameworks presented significantly higher vertical misfit values than those found for framework cemented on prepared abutments and laser welding techniques (P Laser welding and framework cemented on prepared abutments are effective techniques to improve the adaptation of three-unit implant-supported prostheses. These techniques presented similar fit.

  10. Classification of delocalization power of global unitary operations in terms of LOCC one-piece relocalization

    Akihito Soeda

    2010-06-01

    Full Text Available We study how two pieces of localized quantum information can be delocalized across a composite Hilbert space when a global unitary operation is applied. We classify the delocalization power of global unitary operations on quantum information by investigating the possibility of relocalizing one piece of the quantum information without using any global quantum resource. We show that one-piece relocalization is possible if and only if the global unitary operation is local unitary equivalent of a controlled-unitary operation. The delocalization power turns out to reveal different aspect of the non-local properties of global unitary operations characterized by their entangling power.

  11. Immediate loading of mandibular overdentures supported by one-piece, direct metal laser sintering mini-implants: a short-term prospective clinical study.

    Mangano, Francesco G; Caprioglio, Alberto; Levrini, Luca; Farronato, Davide; Zecca, Piero A; Mangano, Carlo

    2015-02-01

    Only a few studies have dealt with immediately loaded, unsplinted mini-implants supporting ball attachment-retained mandibular overdentures (ODs). The aim of this study is to evaluate treatment outcomes of ball attachment-retained mandibular ODs supported by one-piece, unsplinted, immediately loaded, direct metal laser sintering (DMLS) mini-implants. Over a 4-year period (2009 to 2012), all patients referred to the Dental Clinic, University of Varese, and to a private practice for treatment with mandibular ODs were considered for inclusion in this study. Each patient received three or four DMLS mini-implants. Immediately after implant placement, a mandibular OD was connected to the implants. At each annual follow-up session, clinical and radiographic parameters were assessed, including the following outcome measures: 1) implant failures; 2) peri-implant marginal bone loss; and 3) complications. Statistical analysis was conducted using a life-table analysis. A total of 231 one-piece DMLS mini-implants were inserted in 62 patients. After 4 years of loading, six implants failed, giving an overall cumulative survival rate of 96.9%. The mean distance between the implant shoulder and the first visible bone-to-implant contact was 0.38 ± 0.25 and 0.62 ± 0.20 mm at the 1- and 4-year follow-up examinations, respectively. An incidence of 6.0% of biologic complications was reported; prosthetic complications were more frequent (12.9%). Within the limits of this study, it can be concluded that the immediate loading of one-piece, unsplinted, DMLS titanium mini-implants by means of ball attachment-supported mandibular ODs is a successful treatment procedure. Long-term follow-up studies are needed to confirm these results.

  12. Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants

    Stefan Ihde

    2018-01-01

    Full Text Available The aim of this article was to present the clinical application of a new, smooth surfaced one-piece bicortical screw implant with immediate loading protocol. An 18-year-old, healthy male patient with a history of total dislocation and replantation of teeth 11 and 21 in early childhood was admitted to the clinic. Teeth 11 and 21 were extracted, and two long one-piece implants were inserted at extraction sockets in one surgical session under local anesthesia. Temporary composite crowns were placed in the patient on the same day. After 3 months, the single-phase two-layer impression was made and the composite crowns were replaced with metal-ceramic crowns. After 12 months, satisfactory aesthetic and functional results were obtained.

  13. Implant Gigi One-Piece vs Two-Pieces dalam Praktek Sehari-Hari

    Kurnia, Dian Lestari; Ramadhani, Amilia; Hudyono, Rikko

    2014-01-01

    Saat ini, implant merupakan pilihan terbaik untuk menggantikan gigi yang tanggal, akan tetapi prosedur pemasangannya terbilang rumit dan memerlukan prosedur bedah kedua untuk pemasangan prostetik. Beberapa komplikasi seperti screw patah atau longgar dan adanya celah mikro pada batas pertemuan implant dan abutment dapat menyebabkan kegagalan implant. Studi kasus ini bertujuan untuk membahas mengenai keuntungan dan kerugian desain implant gigi one-piece dan two-pieces. Kasus pertama, seorang wa...

  14. Implant Gigi One-Piece Vs Two-Pieces Dalam Praktek Sehari-Hari

    Kurnia, Dian Lestari; Ramadhani, Amilia; Hudyono, Rikko

    2014-01-01

    Saat ini, implant merupakan pilihan terbaik untuk menggantikan gigi yang tanggal, akan tetapi prosedur pemasangannya terbilang rumit dan memerlukan prosedur bedah kedua untuk pemasangan prostetik. Beberapa komplikasi seperti screw patah atau longgar dan adanya celah mikro pada batas pertemuan implant dan abutment dapat menyebabkan kegagalan implant. Studi kasus ini bertujuan untuk membahas mengenai keuntungan dan kerugian desain implant gigi one-piece dan two-pieces. Kasus pertama, seorang wa...

  15. FEA and microstructure characterization of a one-piece Y-TZP abutment.

    da Silva, Lucas Hian; Ribeiro, Sebastião; Borges, Alexandre Luís Souto; Cesar, Paulo Francisco; Tango, Rubens Nisie

    2014-11-01

    The most important drawback of dental implant/abutment assemblies is the need for a fixing screw. This study aimed to develop an esthetic one-piece Y-TZP abutment to suppress the use of the screw. Material characterization was performed using a bar-shaped specimen obtained by slip-casting to validate the method prior to prototype abutment fabrication by the same process. The mechanical behavior of the prototype abutment was verified and compared with a conventional abutment by finite element analysis (FEA). The abutment was evaluated by micro-CT analysis and its density was measured. FEA showed stress concentration at the first thread pitch during installation and in the cervical region during oblique loading for both abutments. However, stress concentration was observed at the base of the screw head and stem in the conventional abutment. The relative density for the fabricated abutment was 95.68%. Micro-CT analysis revealed the presence of elongated cracks with sharp edges over the surface and porosity in the central region. In the light of these findings, the behavior of a one-piece abutment is expected to be better than that of the conventional model. New studies should be conducted to clarify the performance and longevity of this one-piece Y-TZP abutment. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  16. An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis.

    de Aguiar, Fábio Afrânio; Tiossi, Rodrigo; Rodrigues, Renata Cristina Silveira; Mattos, Maria de Gloria Chiarello; Ribeiro, Ricardo Faria

    2009-04-01

    The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N.cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer's test (p screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mum) was significantly different (p 0.05) from the group transversally sectioned (31.42 +/- 20.68 microm). On the tightened side, no significant differences were found between the groups (p > 0.05). Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.

  17. Case study for one-piece removal method of reactor vessel of nuclear ship 'Mutsu'

    Nagane, Satoru; Kitahara, Katsumi; Yoshikawa, Seiji; Miyasaka, Yasuhiko; Fukumura, Nobuo; Nisizawa, Ichiou

    2010-01-01

    A reactor installed at the center part of the nuclear ship 'Mutsu' has been stored safely and exhibited in a reactor room building since 1996. The reactor vessel and its internals are key components because of main radioactive wastes for the reasonable decommissioning plan in the future. This report describes the one-piece removal method as the one package of the reactor vessel with its internals intact with a shipping container or additional shields. The reactor vessel package (Max.100ton) will be classified acceptable for burial at the low level radioactive waste (LLW), which will be buried at a LLW pit facility under waste disposal regulations. And also, the package will be classified as an IP-2-equivalent package according to the requirement for Shipments and Packagings. (author)

  18. Mandibular implant-supported overdentures: Prosthetic overview

    Fahad A Al-Harbi

    2018-01-01

    Full Text Available Implant-supported overdentures are becoming the treatment of choice for the completely edentulous mandible. They significantly improve the quality of life in edentulous patients. For this review article, the literature was searched to identify pertinent studies. No meta-analysis was conducted because of high heterogeneity within the literature. Accordingly, in this review article, the author provides an update on implant-supported mandible overdentures with regard to the number of implants, type of loading, stress–strain distribution, mode of implant-to-denture attachment, occlusal considerations and complications.

  19. Nilai Pendidikan Dalam Komik One Piece Jilid 1-23 Karya Eiichiro Oda (Sebuah Tinjauan Sosiologi Sastra)

    Furqon, Muhammad Taufiq

    2013-01-01

    Furqon, Muhammad Taufiq. 2013. “Nilai Pendidikan dalam Komik One Piece Jilid 1-23 Karya Eiichiro Oda”. Skripsi S-1 Fakultas Ilmu Budaya Universitas Diponegoro Semarang. Permasalahan dalam penelitian ini adalah komik One Piece dilihat dari bentuknya hanya terdiri dari gambar dan teks, tetapi ada unsur-unsur fiksi terdapat di dalamnya seperti adanya tema, tokoh, latar,dan ada amanat yang ingin disampaikan pengarangnya. Sehingga pemahaman dan pemaknaan terhadapnya mampu memberikan manfaat bagi p...

  20. Masticatory function with implant-supported overdentures

    van Kampen, FMC; van der Bilt, A; Cune, MS; Fontijn-Tekamp, FA; Bosman, F

    The type of attachment that is used in implant-supported mandibular overdentures may influence the retention and stability of the prosthesis and, thus, masticatory function. In this within- subject cross- over clinical trial, we examined the hypothesis that greater retention and stability of the

  1. Interface magnons. Magnetic superstructure

    Djafari-Rouhani, B.; Dobrzynski, L.

    1975-01-01

    The localized magnons at an interface between two Heisenberg ferromagnets are studied with a simple model. The effect of the coupling at the interface on the existence condition for the localized modes, the dispersion laws and the possible occurrence of magnetic superstructures due to soft modes are investigated. Finally a comparison is made with the similar results obtained for interface phonons [fr

  2. Nanoparticle assemblies and superstructures

    Kotov, Nicholas A

    2006-01-01

    ... building blocks of larger and more complex systems. Therefore, the present challenge of nanoscale science is to shift from making certain building blocks to organizing them in one-, two-, and three-dimensional structures. Such assemblies and superstructures are the next logical step in the development of nanoscience and nanotechnology. In this re...

  3. Implant supported overdentures--the Copenhagen experience

    Gotfredsen, K

    1997-01-01

    OBJECTIVES: To evaluate the functional and biological effect of implant-supported overdenture treatment in the lower jaw. METHODS AND MATERIALS: Thirty-two patients were consecutively treated with Astra Tech implants in the lower jaw for retaining overdentures. All implants had a diameter of 3.5 mm...... and all but two of the implants were longer than 10 mm. For the implant supported overdentures two methods of attachment were used, a bar or a ball. RESULTS: One of 69 fixtures was lost during the 4-5 year observation period. The mean bone loss for all fixtures was less than 0.2 mm per year. Complications...... quality and quantity is sufficient, two implants can support an overdenture in the lower jaw, providing prosthesis which functions well....

  4. One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study.

    Siddiqi, A; Duncan, W J; De Silva, R K; Zafar, S

    2016-01-01

    Reports have documented titanium (Ti) hypersensitivity after dental implant treatment. Alternative materials have been suggested including zirconia (Zr) ceramics, which have shown predictable osseointegration in animal studies and appear free of immune responses. The aim of the research was to investigate the bone-to-implant contact (BIC) of one-piece Zr, compared with one-piece Ti implants, placed in the jaws and femurs of domestic sheep. Ten New Zealand mixed breed sheep were used. A One-piece prototype Ti (control) and one Zr (test) implant were placed in the mandible, and one of each implant (Ti and Zr) was placed into the femoral epicondyle of each animal. The femur implants were submerged and unloaded; the mandibular implants were placed using a one-stage transgingival protocol and were nonsubmerged. After a healing period of 12 weeks, %BIC was measured. The overall survival rate for mandibular and femur implants combined was 87.5%. %BIC was higher for Zr implants versus Ti implants in the femur (85.5%, versus 78.9%) ( p = 0.002). Zirconia implants in the mandible showed comparable %BIC to titanium implants (72.2%, versus 60.3%) ( p = 0.087). High failure rate of both Zr and Ti one-piece implants in the jaw could be attributed to the one-piece design and surface characteristics of the implant that could have influenced osseointegration. Further clinical trials are recommended to evaluate the performance of zirconia implants under loading conditions.

  5. Treatment planning: implant-supported partial overdentures.

    Chee, Winston W L

    2005-04-01

    When multiple anterior teeth are missing, many options of replacement are available. Traditionally, the choice was between a fixed or removable prostheses. Today, with the predictability of dental implants, the options of tooth replacement range from removable partial dentures to implant-supported fixed prostheses. The choice of which restoration that will best provide occlusion and esthetics depends on multiple factors including the number and location of missing teeth, the residual ridge form in relation to the replacement teeth, the relationship of the maxillary and mandibular anterior teeth, the condition of teeth adjacent to the edentulous span, the amount of bone available for implant placement, the patients "smile line" and display of teeth, lip support, and financial constraints. When there is minimal loss of the ridge contour, restorations that emerge from the ridge are the most functional and esthetic restorations, adhesive-type fixed partial dentures, conventional fixed partial dentures, and implant-supported restorations can be indicated with the choice of restoration dependent on a risk benefit and cost benefit analysis. When there is a loss of ridge contour due to residual ridge resorption or trauma, the decision becomes more complex as not only does the tooth structure need to be replaced, the ridge form also has to be replaced. (Figures 1 and 2). This can be assessed clinically as illustrated by Figures 1 and 2 where a dis crepancy in arch form and ridge form in relation to the adjacent teeth and/or opposing arch can be observed. Other considerations are lip support and display of the teeth when smiling. This article presents a case and rationale for implant-supported par tial overdentures. Many authors have written on the merits of com plete overdentures. The complete overdenture has proven to be an improvement over conventional complete prostheses with respect to chewing efficiency, patient comfort and satisfaction. In partial edentulism, the

  6. Superstructure of stapes

    Horiuchi, Yasuharu; Hunai, Hiroaki; Ichimura; Keiiti; Iinuma, Toshitaka; Oyama, Kazuyuki

    1989-01-01

    High-resolution Computed Tomography (HRCT) of the temporal bone has now become a routine test for the diagnosis of various temporal bone lesions. Correct assessment of such minute structures as ossicles, especially stapes, is important in the pre-operative HRCT evaluation. On the other hand, analysis for the reliability of HRCT findings has not been done, including the superstructure of the stapes. A retrospectively study was done in order to assess the availability of HRCT findings in axial overlapping scans in 226 ears, with respect to the superstructures of stapes. The study was concerned with the analysis of HRCTs of 148 normal ears, 71 ears of chronic otitis media and 7 ears of ossicular abnormalities. HRCT findings were compared to those of surgeries in pathological cases. The present study revealed that the superstructures of stapes are noted in 70% when the stapes is surrounded by air. The major limitations in the proper analysis of stapes by HRCT are partial volume averaging and effects of soft tissue silhouetting, this is especially so when the stapes is surrounded by soft tissue density. (author)

  7. Implant supported overdentures--the Copenhagen experience

    Gotfredsen, K

    1997-01-01

    included 15 fractures of the ball attachment and 26 episodes of looseness of the matrices holding the screw in place. Patient satisfaction with the treatment of the lower jaw was high although 7 patients found that control of the upper denture was poor following treatment. CONCLUSIONS: When the bone...... and all but two of the implants were longer than 10 mm. For the implant supported overdentures two methods of attachment were used, a bar or a ball. RESULTS: One of 69 fixtures was lost during the 4-5 year observation period. The mean bone loss for all fixtures was less than 0.2 mm per year. Complications...

  8. A Novel Computer-Aided Design/Computer-Assisted Manufacture Method for One-Piece Removable Partial Denture and Evaluation of Fit.

    Ye, Hongqiang; Li, Xinxin; Wang, Guanbo; Kang, Jing; Liu, Yushu; Sun, Yuchun; Zhou, Yongsheng

    2018-02-15

    To investigate a computer-aided design/computer-aided manufacturing (CAD/CAM) process for producing one-piece removable partial dentures (RPDs) and to evaluate their fits in vitro. A total of 15 one-piece RPDs were designed using dental CAD and reverse engineering software and then fabricated with polyetheretherketone (PEEK) using CAM. The gaps between RPDs and casts were measured and compared with traditional cast framework RPDs. Gaps were lower for one-piece PEEK RPDs compared to traditional RPDs. One-piece RPDs can be manufactured by CAD/CAM, and their fits were better than those of traditional RPDs.

  9. Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

    Jalil Ghanbarzadeh

    2013-12-01

    Full Text Available Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one-piece abutments (Solid® and in groups three and four, 10 ITI two-piece abutments (Synocta® were placed on the implants. In groups one and three abutments were tightened by 5 experienced males and 5 experienced females using a handheld driver. In groups two and four abutments were tightened using a torque wrench with torque values of 10, 20 and 35 N.cm. Insertion torque and removal torque values of the abutments were measured with a digital torque meter. Results: The insertion torque values (ITVs of males in both abutments were significantly higher than those of females. ITVs in both Solid® and Synocta® abutments tightened with a handheld screwdriver were similar to the torque of 20 N.cm in the torque wrench. Removal torque values (RTVs of solid® abutments were higher than those of synocta® abutments. Conclusion: The one- piece abutments (solid® showed higher RTVs than the two-piece abutments (synocta®. Hand driver does not produce sufficient preload force for the final tightening of the abutment

  10. Fabricating a Mandibular Implant Supported Overdenture with a Suspended Framework

    Ahuja, Swati; Jain, Vinay; Cagna, David; Wicks, Russell

    2012-01-01

    The introduction of implant-supported overdentures as a clinical alternative has improved the quality of life of the edentulous population. Implant-supported overdentures have diminished many of the problems associated with conventional dentures by providing improved retention, stability, function, esthetics and physical and emotional health. Greater support and stability of the implant borne prosthesis is associated with improved bite force and oral function for overdentures when compared to...

  11. Immediate implant-supported oral rehabilitation using a photocurable plastic skull model and laser welding. A technical note on the screw-retained type: Part 1.

    Tomotake, Yoritoki; Ishida, Osamu; Kanitani, Hideo; Ichikawa, Tetsuo

    2002-01-01

    This article describes a new procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus. Preoperatively, the framework was fabricated on a photocurable resin skull model produced from a CT scan and individually designed guide template. The implants were immediately placed using the guide template; laser welding connected the components of framework. Despite the custom-made prosthesis, the total treatment from implant placement to superstructure placement can be completed within only 1 day. This procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus may be useful for any implant system and patient.

  12. Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation.

    Lumetti, S; Ghiacci, G; Macaluso, G M; Amore, M; Galli, C; Calciolari, E; Manfredi, E

    2016-01-01

    Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD) and oral parafunction (OP) rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.

  13. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses.

    Wu, Aaron Yu-Jen; Hsu, Jui-Ting; Chee, Winston; Lin, Yun-Te; Fuh, Lih-Jyh; Huang, Heng-Li

    2016-09-01

    Small-diameter dental implants are associated with a higher risk of implant failure. This study used both three-dimensional finite-element (FE) simulations and in-vitro experimental tests to analyze the stresses and strains in both the implant and the surrounding bone when using one-piece (NobelDirect) and two-piece (NobelReplace) small-diameter implants, with the aim of understanding the underlying biomechanical mechanisms. Six experimental artificial jawbone models and two FE models were prepared for one-piece and two-piece 3.5-mm diameter implants. Rosette strain gauges were used for in-vitro tests, with peak values of the principal bone strain recorded with a data acquisition system. Implant stability as quantified by Periotest values (PTV) were also recorded for both types of implants. Experimental data were analyzed statistically using Wilcoxon's rank-sum test. In FE simulations, the peak value and distribution of von-Mises stresses in the implant and bone were selected for evaluation. In in-vitro tests, the peak bone strain was 42% lower for two-piece implants than for one-piece implants. The PTV was slightly lower for one-piece implants (PTV = -6) than for two-piece implants (PTV = -5). In FE simulations, the stresses in the bone and implant were about 23% higher and 12% lower, respectively, for one-piece implants than those for two-piece implants. Due to the higher peri-implant bone stresses and strains, one-piece implants (NobelDirect) might be not suitable for use as small-diameter implants. Copyright © 2016. Published by Elsevier B.V.

  14. Occlusal wear of provisional implant-supported restorations

    Santing, Hendrik J.; Kleverlaan, Cornelis J.; Werner, Arie; Feilzer, Albert J.; Raghoebar, Gerry M.; Meijer, Henny J. A.

    BACKGROUND: Implant-supported provisional restorations should be resistant to occlusal wear. PURPOSE: The purpose of this laboratory study was to evaluate three-body wear of three indirect laboratory composite resins, five chair side bis-acryl resin-based materials, and two chair side

  15. Occlusal wear of provisional implant-supported restorations.

    Santing, Hendrik J; Kleverlaan, Cornelis J; Werner, Arie; Feilzer, Albert J; Raghoebar, Gerry M; Meijer, Henny J A

    2015-02-01

    Implant-supported provisional restorations should be resistant to occlusal wear. The purpose of this laboratory study was to evaluate three-body wear of three indirect laboratory composite resins, five chair side bis-acryl resin-based materials, and two chair side methacrylate-based materials used to fabricate provisional implant-supported restorations. The materials were handled and cured according to the manufacturers' instructions. The three-body wear was measured 1 day, 3 days, 7 days, 4 weeks, and 8 weeks after curing using the ACTA wear device. Wear rate decreased significantly after 8 weeks compared with the first day for all tested materials, except for Estenia C&B. The three-body wear of two indirect laboratory composite resins, that is, Estenia C&B and Solidex, was significantly less compared with all other tested materials used for fabricating provisional implant-supported restorations. Of the chair side materials, the wear rate of Protemp Crown Paste was significantly less compared with the others materials used to fabricate chair side provisional implant-supported restorations. The methacrylate-based materials, Temdent Classic and Trim, showed extreme high wear rates. Based on the results of this laboratory study on long-term wear, the use of indirect composite resin is preferred over chair side methacrylate-based materials when the provisional implant-supported restoration has to be in service for a long period of time. Of the investigated materials, only Estenia C&B and Solidex showed wear rate comparable with posterior resin composites. © 2013 Wiley Periodicals, Inc.

  16. Standard plans for timber bridge superstructures

    James P. Wacker; Matthew S. Smith

    2001-01-01

    These standardized bridge plans are for superstructures consisting of treated timber. Seven superstructure types are includes: five longitudinal and two transverse deck systems. Both HS520 and HS25 loadings are included, along with L/360 and L/500 deflection criteria.

  17. Implementing Composite Superstructures in Large Passenger Ships

    Karatzas, Vasileios; Berggreen, Christian; Jensen, Jørgen Juncher

    2015-01-01

    This study focuses on the structural response of the part of the superstructure of a RoPax ferry that has been redesigned using composite materials. The composite superstructure is presented and subsequently compared to the existing steel design considering different loading conditions by the use...

  18. Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation

    S. Lumetti

    2016-01-01

    Full Text Available Oral movement disorders may lead to prosthesis and implant failure due to excessive loading. We report on an edentulous patient suffering from drug-induced tardive dyskinesia (TD and oral parafunction (OP rehabilitated with implant-supported screw-retained prostheses. The frequency and intensity of the movements were high, and no pharmacological intervention was possible. Moreover, the patient refused night-time splint therapy. A series of implant and prosthetic failures were experienced. Implant failures were all in the maxilla and stopped when a rigid titanium structure was placed to connect implants. Ad hoc designed studies are desirable to elucidate the mutual influence between oral movement disorders and implant-supported rehabilitation.

  19. Fracture analysis of randomized implant-supported fixed dental prostheses

    Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.

    2014-01-01

    Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and

  20. Split-Framework in Mandibular Implant-Supported Prosthesis

    Danny Omar Mendoza Marin

    2015-01-01

    Full Text Available During oral rehabilitation of an edentulous patient with an implant-supported prosthesis, mandibular flexure must be considered an important biomechanical factor when planning the metal framework design, especially if implants are installed posterior to the interforaminal region. When an edentulous mandible is restored with a fixed implant-supported prosthesis connected by a fixed full-arch framework, mandibular flexure may cause needless stress in the overall restorative system and lead to screw loosening, poor fit of prosthesis, loss of the posterior implant, and patient’s discomfort due to deformation properties of the mandible during functional movements. The use of a split-framework could decrease the stress with a precise and passive fit on the implants and restore a more natural functional condition of the mandible, helping in the longevity of the prosthesis. Therefore, the present clinical report describes the oral rehabilitation of an edentulous patient by a mandibular fixed implant-supported prosthesis with a split-framework to compensate for mandibular flexure. Clinical Significance. The present clinical report shows that the use of a split-framework reduced the risk of loss of the posterior implants or screws loosening with acceptable patient comfort over the period of a year. The split-framework might have compensated for the mandibular flexure during functional activities.

  1. A novel computer-aided method to fabricate a custom one-piece glass fiber dowel-and-core based on digitized impression and crown preparation data.

    Chen, Zhiyu; Li, Ya; Deng, Xuliang; Wang, Xinzhi

    2014-06-01

    Fiber-reinforced composite dowels have been widely used for their superior biomechanical properties; however, their preformed shape cannot fit irregularly shaped root canals. This study aimed to describe a novel computer-aided method to create a custom-made one-piece dowel-and-core based on the digitization of impressions and clinical standard crown preparations. A standard maxillary die stone model containing three prepared teeth each (maxillary lateral incisor, canine, premolar) requiring dowel restorations was made. It was then mounted on an average value articulator with the mandibular stone model to simulate natural occlusion. Impressions for each tooth were obtained using vinylpolysiloxane with a sectional dual-arch tray and digitized with an optical scanner. The dowel-and-core virtual model was created by slicing 3D dowel data from impression digitization with core data selected from a standard crown preparation database of 107 records collected from clinics and digitized. The position of the chosen digital core was manually regulated to coordinate with the adjacent teeth to fulfill the crown restorative requirements. Based on virtual models, one-piece custom dowel-and-cores for three experimental teeth were milled from a glass fiber block with computer-aided manufacturing techniques. Furthermore, two patients were treated to evaluate the practicality of this new method. The one-piece glass fiber dowel-and-core made for experimental teeth fulfilled the clinical requirements for dowel restorations. Moreover, two patients were treated to validate the technique. This novel computer-aided method to create a custom one-piece glass fiber dowel-and-core proved to be practical and efficient. © 2013 by the American College of Prosthodontists.

  2. Superstructures: First Cold Test and Future Applications

    J. Sekutowicz; C Albrecht; V Ayvazyan; R Bandelmann; T Buttner; P Castro; S Choroba; J Eschke; B Faatz; A Gossel; K Honkavaara; B Horst; J Iverson; K Jensch; H Kaiser; R Kammering; G Kreps; D Kostin; J Lorkiewicz; R Lange; A Matheisen; W -D Moller; H -B Peters; D Proch; K Rehlich; H Schlarb; S Schrieber; D Reschke; S Simrock; W Singer; X Singer; K Twarowski; T Weichert; M Wojtkiewicz; G Wendt; K Zapfe; M Liepe; M Huening; M Ferrario; E Plawski; C Pagani; P Kneisel; G Wu; N Baboi; C Thomas; H Chen; W Huang; C Tang; S Zheng

    2003-01-01

    Superstructures, chains of superconducting multi-cell cavities (subunits) connected by e/2 long tube(s) have been proposed as an alternative layout for the TESLA main accelerator [1]. After three years of preparation, two superstructures, each made of two weakly coupled superconducting 7-cell subunits driven by a single Fundamental Power Coupler (FPC), have been installed in the Tesla Test Facility linac for beam tests. Energy stability, HOM damping, frequency and field adjustment methods were tested. The measured results confirme Superstructures, chains of superconducting multi-cell cavities (subunits) connected by e/2 long tube(s) have been proposed as an alternative layout for the TESLA main accelerator [1]. After three years of preparation, two superstructures, each made of two weakly coupled superconducting 7-cell subunits driven by a single Fundamental Power Coupler (FPC), have been installed in the Tesla Test Facility linac for beam tests. Energy stability, HOM damping, frequency and field adjustment methods were tested. The measured results confirmed expectation on the superstructure performance and proved that an alternative layout for the 800 GeV upgrade of the TESLA collider is feasible. We report on the test and give here an overview of its results. The tests confirmed very good damping of HOMs in superstructures and thus has opened a possible new application of this concept to high current energy recovery machines. We have built two 1.5 GHz copper models of two superstructures: 2x5-cells and 2x2-cells to prove further improvement of HOM damping. This contribution presents also measured results on these models. d expectations on the superstructure performance and proved that an alternative layout for the 800 GeV upgrade of the TESLA collider is feasible. We report on the test and give here an overview of its results

  3. Mastication improvement after partial implant-supported prosthesis use.

    Gonçalves, T M S V; Campos, C H; Gonçalves, G M; de Moraes, M; Rodrigues Garcia, R C M

    2013-12-01

    Partially edentulous patients may be rehabilitated by the placement of removable dental prostheses, implant-supported removable dental prostheses, or partial implant fixed dental prostheses. However, it is unclear the impact of each prosthesis type over the masticatory aspects, which represents the objective of this paired clinical trial. Twelve patients sequentially received and used each of these 3 prosthesis types for 2 months, after which maximum bite force was assessed by a strain sensor and food comminution index was determined with the sieving method. Masseter and temporal muscle thicknesses during rest and maximal clenching were also evaluated by ultrasonography. Each maxillary arch received a new complete denture that was used throughout the study. Data were analyzed by analysis of variance for repeated measures, followed by the Tukey test (p mastication, and the magnitude of this effect was related to prosthesis type.

  4. La traducción de la onomatopeya en el manga One Piece : tipología y técnicas

    Pérez Álvaro, Laura

    2017-01-01

    Treball Final de Grau en Traducció i Interpretació. Codi: TI0983. Curs: 2015/2016 Este trabajo es un estudio de caso de la traducción de las onomatopeyas en el primer tomo del manga One Piece (Eiichiro Oda). El objetivo que se persigue con esta investigación es comprobar si la posición de las onomatopeyas en diferentes lugares de las páginas de un cómic, es decir, dentro o fuera de bocadillo de diálogo, influye en el método de traducción empleado. Los métodos que se incluyen...

  5. Super-structure and building performance

    Van Wyk, Llewellyn V

    2010-11-01

    Full Text Available The super-structure consists predominantly of the load- and no-load-bearing walls-including all doors and windows and suspended floor slabs. The building envelope plays a significant role in the performance of a building, especially with regard...

  6. Immediate prostheses on one-piece trans-mucosal implants in flapless surgical procedures Case Series Report. Part I: full arch rehabilitations

    Aris Petros Tripodakis

    2012-06-01

    Full Text Available Aim: The aim of the present case series report is to illustrate a clinical technique and present the application of onepiece transmucosal implants in flapless surgical procedures, supporting full arch immediate prostheses. Materials and methods: A total of 294 implants (Xive TG, Friadent, Germany have been used to support full arch immediate prostheses, over the last six years and have been in function for at least one year. The surgical placement of five or more implants per case involved immediate extraction and intrasocket flapless placement, combined with minimal flap elevation in the areas of healed extraction sites (43 mandibular and 7 maxillary arches. In all cases immediate provisionalization followed. Detailed three-dimensional cone-beam localized volumetric tomography preceeded the surgical procedures. The delivery of the final ceramo-metal prostheses was accomplished within a 20 day period. Materials and methods: Results Six implants failed to osseointegrate. All other implants are still successfully bearing the final prosthesis for the time that they have been followed. Soft tissue reaction was favorable from both the biologic and esthetic point of view. Conclusion: The flapless placement of one piece implants into edentulous healed sites is a predictable procedure in the presence of abundance of supporting bone as confirmed by 3-D imaging. On the other hand, immediate extraction placement of one piece implants allows the engagement of sound bone located deeper into the socket and provides adequate mechanical support of the soft tissue architecture that is preserved predictably. In all cases the prosthetic procedures are accomplished without disturbing the hardsoft tissue interface as the abutment-prosthesis interface is coronally elevated by the virtual design of the implant.

  7. A Sequential Approach to Implant-Supported Overdentures.

    Kosinski, Timothy

    2016-03-01

    Fabrication of implant-supported maxillary or mandibular overdentures can seem to be difficult procedures. Many things could go wrong and/or unnoticed until the fabrication has been completed. Implants must be correctly surgically placed in viable bone at the proper angulation and spacing within an arch. The type of attachment must be considered and future treatment of the appliance should be simple and efficient. The appliance must function not only initially but also for many years to come. The author has found the use of the GPS attachment to be an ideal tool to achieve the goals of retention and stability. Careful planning is the most important part of this process, and understanding the benefits and risks of creating overdentures should be well understood by the dentists. By sequentially planning and treating these types of cases, the patient is able to function reasonably during the stages of implant healing. The final prosthesis is created and remaining teeth that held the transitional appliance in place are remove on the day of final seating. This is an excellent simplified retentive system option for those patients who are anxious about losing their teeth, even those teeth that are diseased and ugly.

  8. Refusal of implant supported mandibular overdentures by elderly patients.

    Ellis, Janice S; Levine, Alissa; Bedos, Christophe; Mojon, Phillippe; Rosberger, Zeer; Feine, Jocelyne; Thomason, J Mark

    2011-03-01

      The aim of this study was to gain greater in-depth understanding of why elderly patients who are currently dissatisfied with conventional dentures decline implant treatment.   There is strong evidence from high-quality randomised controlled trials to support the use of implant-supported overdentures for the restoration of the edentulous mandible. However, whilst recruiting for randomised clinical trials, researchers have found that a high proportion of potential subjects decline participation, despite the removal of financial constraints.   The study adopted a qualitative approach to provide a rich and deep understanding of people's reasons for refusal. Data were collected through focus group interviews in a two-centre study based in Montreal, Canada and Newcastle, UK. A semi-structured interview schedule was used and iteratively developed as analysis identified themes from previous focus groups. Transcripts of focus groups were coded and emergent themes determined.   Two main themes emerged; patients' fear and anxiety (relating to the pain of surgery, complications of the procedure and immediate post-surgical denture use), and the appropriateness of the procedure in an elderly person.   Fears of pain, complications and social embarrassment, exacerbated by age, are important factors that help explain refusal of implants by elderly patients. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  9. Investigation of the implant-supported overdentures in completely edentulous mandibles

    Yu-Hwa Pan

    2015-12-01

    Conclusion: Our results indicate that implant-supported overdentures provide a reliable and effective alternative to conventional complete mandibular dentures. Overdentures with Hader bars and bilateral, cast ERA attachments resulted in fewer prosthetic complications.

  10. Economic Evaluation of Implant-Supported Overdentures in Edentulous Patients: A Systematic Review.

    Zhang, Qi; Jin, Xin; Yu, Mengliu; Ou, Guoming; Matsui, Hiroyuki; Liang, Xing; Sasaki, Keiichi

    Edentulous patients benefit significantly from implant-supported overdenture prostheses. The purpose of this systematic review was to evaluate the cost-effectiveness of implant-supported overdentures (IODs) for edentulous patients. The search was limited to studies written in English and included an electronic and manual search through MEDLINE (Ovid, 1946 to November 2015), Embase (Ovid, 1966 to November 2015), Cochrane Central Register of Controlled Trials (CENTRAL) (to November 2015), and PubMed (to November 2015). Two investigators extracted the data and assessed the studies independently. No meta-analysis was conducted due to the high heterogeneity within the literature. Of the initial 583 selected articles, 10 studies involving 802 participants were included. Of these, 6 studies had a high risk of bias and the rest had an unclear risk of bias. Implant-supported prostheses were more cost-effective when compared to conventional dentures and fixed implant-supported prostheses. Overdentures supported by two implants and magnet attachment were reported as cost-effective. Implant-supported overdentures are a cost-effective treatment for edentulous patients. More clinical studies with appropriate scientific vigor are required to further assess the cost-effectiveness of implant-supported overdentures.

  11. Superconducting superstructure for the TESLA collider

    Sekutowicz, J.; Tang, C. [DESY, MHF-SL, Hamburg (Germany); Ferrario, M. [INFN, Laboratori Nazionali di Frascati, Rome (Italy)

    1998-04-01

    The Authors discuss the new layout of a cavity chain (superstructure) allowing, the Authors hope, significant cost reduction of the RF system of both linacs of the TESLA linear collider. The proposed scheme increases the fill factor and thus makes an effective gradient of an accelerator higher. The authors present mainly computations that have performed up to now and which encouraged to order the copper model of the scheme, still keeping in mind that experiments with a beam will be necessary to prove if the proposed solution can be used for the acceleration.

  12. Classification system on the selection of number of implants and superstructure design on the basis available vertical restorative space and interforaminal distance for implant supported mandibular overdenture

    Akshay Bhargava

    2016-01-01

    Full Text Available Purpose: The rehabilitation of the edentulous mandible is a challenge due to various limiting factors, of which the available vertical restorative space (AVRS has been well understood in the literature. However, other anatomic variations such as arch form, arch size, and also the interforaminal distance (IFD (due to the presence of mandibular nerve are influential in the selection of size and position of implants, and thereby the prosthetic design. Materials and Method: In the present study, 30 edentulous patients from a group of 300 edentulous patients, representing all the three jaw relations (Class I, II, and III were evaluated for designing a classification that could help in a comprehensive treatment plan for the edentulous mandible. Dental panoramic radiographs of each individual with a trial or final prosthesis were made. The horizontal IFD and AVRS values were calculated. Results: One-way analysis of variance followed by post-hoc test (multiple comparison and Bonferroni method having P < 0.05 as significant value showed an overall mean of 38.9 mm for horizontal distance and 13.69 mm for the AVRS in 30 edentulous patients. Conclusion: The results showed that in the majority of cases (90% there is insufficient space to place a bar attachment supported by five implants for mandibular overdentures. This suggests that a universal treatment plan cannot be followed due to varying anatomic factors. Hence, it becomes imperative to have a set of clinical guidelines based on the AVRS and IFD, for the selection of implant number and type of attachment. The article proposes a simple classification system based on the AVRS and IFD for establishing guidelines in the treatment planning of the edentulous mandible, to aid in selection of implant size, number, and position along with the associated prosthetic design.

  13. Toolbox for super-structured and super-structure free multi-disciplinary building spatial design optimisation

    Boonstra, S.; van der Blom, K.; Hofmeyer, H.; Emmerich, M.T.M.; van Schijndel, A.W.M.; de Wilde, P.

    2018-01-01

    Multi-disciplinary optimisation of building spatial designs is characterised by large solution spaces. Here two approaches are introduced, one being super-structured and the other super-structure free. Both are different in nature and perform differently for large solution spaces and each requires

  14. Elements of implant-supported rehabilitation planning in patients with bruxism.

    Sarmento, Hugo Ramalho; Dantas, Raquel Venâncio Fernandes; Pereira-Cenci, Tatiana; Faot, Fernanda

    2012-11-01

    The rehabilitation of partial or completely edentulous patients with implant-supported prostheses has been widely used, achieving high success rates. However, many studies consider the presence of bruxism as a contraindication for this treatment modality. The purpose of this study was to revise the literature and identify risk factors in implant-supported rehabilitation planning in subjects with bruxism. Available literature was searched through Medline, with no time limit, including only studies in English. Topics discussed were etiology of bruxism and its implications on dental implants, biomechanical considerations regarding the overload on dental implants, and methods to prevent the occurrence of overloads in implant-supported prostheses. The rehabilitation of bruxers using implant-supported prostheses, using implants with adequate length and diameter, as well as proper positioning seems to be a reliable treatment, with reduced risks of failure. Bruxism control through the use of a nightguard by rigid occlusal stabilization appliance relieved in the region of implants is highly indicated. Although it is clear that implant-supported rehabilitation of patients with bruxism requires adequate planning and follow-up, well-designed randomized controlled trials are needed to provide reliable evidence on the long-term success of this treatment modality.

  15. Neuromuscular coordination of masticatory muscles in subjects with two types of implant-supported prostheses.

    Ferrario, Virgilio F; Tartaglia, Gianluca M; Maglione, Michele; Simion, Massimo; Sforza, Chiarella

    2004-04-01

    To compare the electromyographic (EMG) characteristics of masticatory muscles in patients with fixed implant-supported prostheses and implant overdentures. Nineteen subjects aged 45-79 years were examined. Fourteen were edentulous and had been successfully rehabilitated with (a) maxillary and mandibular implant-supported fixed prostheses (seven patients); (b) mandibular implant overdentures and maxillary complete dentures (seven patients). Five control subjects had natural dentition or single/partial (no more than two teeth) tooth or implant fixed dentures. Surface EMG of the masseter and temporal muscles was performed during unilateral gum chewing and during maximum teeth clenching. To reduce biological and instrumental noise, all values were standardized as percentage of a maximum clenching on cotton rolls. During clenching, temporal muscle symmetry was larger in control subjects and fixed implant-supported prosthesis patients than in overdenture patients (analysis of variance, P=0.005). No differences were found in masseter muscle symmetry or in muscular torque. Muscle activities (integrated areas of the EMG potentials over time) were significantly larger in control subjects than in implant-supported prosthesis patients (P=0.014). In both patient groups, a poor neuromuscular coordination during chewing, with altered muscular patterns, and a smaller left-right symmetry than in control subjects were found (P=0.05). No differences in masticatory frequency were found. Surface EMG analysis of clenching and chewing showed that fixed implant-supported prostheses and implant overdentures were functionally equivalent. Neuromuscular coordination during chewing was inferior to that found in subjects with natural dentition.

  16. Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.

    Altarawneh, Sandra; Limmer, Bryan; Reside, Glenn J; Cooper, Lyndon

    2015-01-01

    This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed prosthesis is the metal acrylic (hybrid), with ceramo-metal prostheses being used less commonly in complete edentulism. However, both of these prostheses designs are associated with reported complications of screw loosening or fracture and chipping of acrylic resin and porcelain. Monolithic zirconia implant-supported fixed prostheses have the potential for reduction of such complications. In this case, the CAD/CAM concept was utilized in fabrication of maxillary and mandibular screw-retained implant-supported fixed prostheses using monolithic zirconia. Proper treatment planning and execution coupled with utilizing advanced technologies contributes to highly esthetic results. However, long-term studies are required to guarantee a satisfactory long-term outcome of this modality of treatment. This case report describes the clinical and technical procedures involved in fabrication of maxillary and mandibular implant-supported fixed prostheses using monolithic zirconia as a treatment of edentulism, and proposes the possible advantages associated with using monolithic zirconia in eliminating dissimilar interfaces in such prostheses that are accountable for the most commonly occurring technical complication for these prostheses being chipping and fracture of the veneering material. © 2015 Wiley Periodicals, Inc.

  17. Enhanced thermophysical properties via PAO superstructure

    Pournorouz, Zahra; Mostafavi, Amirhossein; Pinto, Aditya; Bokka, Apparao; Jeon, Junha; Shin, Donghyun

    2017-01-01

    For the last few years, molten salt nanomaterials have attracted many scientists for their enhanced specific heat by doping a minute concentration of nanoparticles (up to 1% by weight). Likewise, enhancing the specific heat of liquid media is important in many aspects of engineering such as engine oil, coolant, and lubricant. However, such enhancement in specific heat was only observed for molten salts, yet other engineering fluids such as water, ethylene glycol, and oil have shown a decrease of specific heat with doped nanoparticles. Recent studies have shown that the observed specific heat enhancement resulted from unique nanostructures that were formed by molten salt molecules when interacting with nanoparticles. Thus, such enhancement in specific heat is only possible for molten salts because other fluids may not naturally form such nanostructures. In this study, we hypothesized such nanostructures can be mimicked through in situ formation of fabricated nano-additives, which are putative nanoparticles coated with useful organic materials (e.g., polar-group-ended organic molecules) leading to superstructures, and thus can be directly used for other engineering fluids. We first applied this approach to polyalphaolefin (PAO). A differential scanning calorimeter (DSC), a rheometer, and a customized setup were employed to characterize the heat capacity, viscosity, and thermal conductivity of PAO and PAO with fabricated nano-additives. Results showed 44.5% enhanced heat capacity and 19.8 and 22.98% enhancement for thermal conductivity and viscosity, respectively, by an addition of only 2% of fabricated nanostructures in comparison with pure PAO. Moreover, a partial melting of the polar-group-ended organic molecules was observed in the first thermal cycle and the peak disappeared in the following cycles. This indicates that the in situ formation of fabricated nano-additives spontaneously occurs in the thermal cycle to form nanostructures. Figure of merit analyses have

  18. Enhanced thermophysical properties via PAO superstructure.

    Pournorouz, Zahra; Mostafavi, Amirhossein; Pinto, Aditya; Bokka, Apparao; Jeon, Junha; Shin, Donghyun

    2017-12-01

    For the last few years, molten salt nanomaterials have attracted many scientists for their enhanced specific heat by doping a minute concentration of nanoparticles (up to 1% by weight). Likewise, enhancing the specific heat of liquid media is important in many aspects of engineering such as engine oil, coolant, and lubricant. However, such enhancement in specific heat was only observed for molten salts, yet other engineering fluids such as water, ethylene glycol, and oil have shown a decrease of specific heat with doped nanoparticles. Recent studies have shown that the observed specific heat enhancement resulted from unique nanostructures that were formed by molten salt molecules when interacting with nanoparticles. Thus, such enhancement in specific heat is only possible for molten salts because other fluids may not naturally form such nanostructures. In this study, we hypothesized such nanostructures can be mimicked through in situ formation of fabricated nano-additives, which are putative nanoparticles coated with useful organic materials (e.g., polar-group-ended organic molecules) leading to superstructures, and thus can be directly used for other engineering fluids. We first applied this approach to polyalphaolefin (PAO). A differential scanning calorimeter (DSC), a rheometer, and a customized setup were employed to characterize the heat capacity, viscosity, and thermal conductivity of PAO and PAO with fabricated nano-additives. Results showed 44.5% enhanced heat capacity and 19.8 and 22.98% enhancement for thermal conductivity and viscosity, respectively, by an addition of only 2% of fabricated nanostructures in comparison with pure PAO. Moreover, a partial melting of the polar-group-ended organic molecules was observed in the first thermal cycle and the peak disappeared in the following cycles. This indicates that the in situ formation of fabricated nano-additives spontaneously occurs in the thermal cycle to form nanostructures. Figure of merit analyses have

  19. Impact of implant-supported prostheses on nutritional status and oral health perception in edentulous patients.

    El Osta, Nada; El Osta, Lana; Moukaddem, Farah; Papazian, Tatiana; Saad, Robert; Hennequin, Martine; Rabbaa Khabbaz, Lydia

    2017-04-01

    Improvement of nutritional status and perception of oral health are supposed to be different with complete conventional denture or implant-supported fixed or removable prostheses. Since no study has been conducted in Lebanon, the aim of our study was to assess the nutritional status and oral heath related quality of life (OHRQoL) in totally edentulous patients after treatment with complete denture or implant supported-prostheses. This was an observational clinical prospective study. A convenient sample of Lebanese people aged 60 years or more was selected between September 2013 and July 2015 from the Departments of removable and fixed prosthesis at Saint-Joseph University of Beirut. The treatment options included complete denture, implant-supported complete denture and implant-supported fixed prostheses. Nutritional status and OHRQoL were assessed with the Mini-Nutritional Assessment Index (MNA) and the Geriatric Oral Health Assessment Index (GOHAI) respectively at Baseline (first visit before treatment), 2-3 weeks after treatment (t1), 3 months (t2) and 6 months (t3) after treatment. Fifty-one participants (mean age: 69.39 ± 7.164 years) were included. The results have shown an improvement over time in nutritional status and OHRQoL for all treatment groups. However, 2-3 weeks after treatment the number of participants at risk of malnutrition was higher with complete removable denture, intermediate with implant-supported complete denture and lower with implant-supported fixed prostheses (p-value = 0.049). Moreover, the mean GOHAI score was significantly lower over time with complete removable denture compared to implant-supported prostheses (p-value nutritional status for implant supported-prostheses compared to conventional removable dentures. Therefore, it is fundamental that dentists communicate with their patients about implant treatment to understand their expectations, to explain the outcomes and achieve the desired clinical result. Copyright © 2017

  20. ELABORATION OF THE SUPERSTRUCTURE OF THE BULGARIAN HOTEL INDUSTRY

    Tanya Dabeva

    2010-12-01

    Full Text Available The purpose of the paper is to suggest some terms of reference for the elaboration of the superstructure of the Bulgarian hotel industry. The suggestions are based on the analysis of the superstructure at present. Its capacity, main types of accommodation establishments and their distribution by categories and territory are examined. An analysis is made of some resulting indices such as overnight stays and average stay. The main positive, respectively negative features of the superstructure have been analyzed. Concrete terms of reference have been given in order to overcome the problems specified.

  1. The effect of flexible acrylic resin on masticatory muscle activity in implant-supported mandibular overdentures: a controlled clinical trial

    Ibraheem, Eman Mostafa Ahmed; Nassani, Mohammad Zakaria

    2016-01-01

    Background It is not yet clear from the current literature to what extent masticatory muscle activity is affected by the use of flexible acrylic resin in the construction of implant-supported mandibular overdentures. Objective To compare masticatory muscle activity between patients who were provided with implant-supported mandibular overdentures constructed from flexible acrylic resin and those who were provided with implant-supported mandibular overdentures constructed from heat-cured conven...

  2. Treatment Outcome and Patient Satisfaction with Two Adjacent Implant-Supported Restorations in the Esthetic Zone

    Tymstra, Nynke; Meijer, Henny J. A.; Stellingsma, Kees; Raghoebar, Gerry M.; Vissink, Arjan

    2010-01-01

    The purpose of this study was to evaluate the clinical and radiographic parameters as well as the esthetic outcome of two adjacent implant-supported restorations and the surrounding peri-implant mucosa in the maxillary esthetic zone. Ten patients were treated with two adjacent implants in the

  3. Implant-supported removable partial dentures in the mandible : A 3-16 year retrospective study

    Jensen, Charlotte; Meijer, Henny J A; Raghoebar, Gerry M; Kerdijk, Wouter; Cune, Marco S

    PURPOSE: The purpose of this retrospective study was to assess performance, together with biological and technical complications, of implant-supported removable partial dentures (ISRPD) in mandibular Kennedy class I situations with implants placed in the anterior or posterior position. METHODS: 23

  4. Cost-effectiveness of implant-supported mandibular removable partial dentures

    Jensen, Charlotte; Ross, Jamila; Feenstra, Talitha L; Raghoebar, Gerry M; Speksnijder, Caroline; Meijer, Henny J A; Cune, Marco S

    ObjectivesThe aim of this study was to conduct a cost-effectiveness analysis comparing conventional removable partial dentures (RPDs) and implant-supported RPDs (ISRPDs) treatment in patients with an edentulous maxilla and a bilateral free-ending situation in the mandible. Material and methodsThirty

  5. Implant-supported removable partial dentures in the mandible : A 3-16 year retrospective study

    Jensen, Charlotte; Meijer, Henny J. A.; Raghoebar, Gerry M.; Kerdijk, Wouter; Cune, Marco S.

    Purpose: The purpose of this retrospective study was to assess performance, together with biological and technical complications, of implant-supported removable partial dentures (ISRPD) in mandibular Kennedy class I situations with implants placed in the anterior or posterior position. Methods: 23

  6. Integral ceramic superstructure evaluation using time domain optical coherence tomography

    Sinescu, Cosmin; Bradu, Adrian; Topala, Florin I.; Negrutiu, Meda Lavinia; Duma, Virgil-Florin; Podoleanu, Adrian G.

    2014-02-01

    Optical Coherence Tomography (OCT) is a non-invasive low coherence interferometry technique that includes several technologies (and the corresponding devices and components), such as illumination and detection, interferometry, scanning, adaptive optics, microscopy and endoscopy. From its large area of applications, we consider in this paper a critical aspect in dentistry - to be investigated with a Time Domain (TD) OCT system. The clinical situation of an edentulous mandible is considered; it can be solved by inserting 2 to 6 implants. On these implants a mesostructure will be manufactured and on it a superstructure is needed. This superstructure can be integral ceramic; in this case materials defects could be trapped inside the ceramic layers and those defects could lead to fractures of the entire superstructure. In this paper we demonstrate that a TD-OCT imaging system has the potential to properly evaluate the presence of the defects inside the ceramic layers and those defects can be fixed before inserting the prosthesis inside the oral cavity. Three integral ceramic superstructures were developed by using a CAD/CAM technology. After the milling, the ceramic layers were applied on the core. All the three samples were evaluated by a TD-OCT system working at 1300 nm. For two of the superstructures evaluated, no defects were found in the most stressed areas. The third superstructure presented four ceramic defects in the mentioned areas. Because of those defects the superstructure may fracture. The integral ceramic prosthesis was send back to the dental laboratory to fix the problems related to the material defects found. Thus, TD-OCT proved to be a valuable method for diagnosing the ceramic defects inside the integral ceramic superstructures in order to prevent fractures at this level.

  7. Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review.

    Rutkunas, Vygandas; Mizutani, Hiroshi; Peciuliene, Vytaute; Bendinskaite, Ruta; Linkevicius, Tomas

    2008-01-01

    Research data regarding maxillary complete denture outcome with two-implant supported mandibular overdentures are not consistent. Considering multiple publications on implant supported mandibular overdentures, it was decided to summarize currently present evidence on the maxillary complete dentures opposed by implant-supported mandibular overdentures, and analyze factors that could potentially influence the outcomes. The articles from 1985 to 2007 related to the topic were identified in the online MEDLINE/Pubmed and other databases and manually. Primary articles were scanned, and irrelevant studies were excluded from the further review process. Potentially relevant titles and abstracts were provisionally included for consideration on the basis of full text articles. Full text articles were obtained from on-line and printed sources. The data from the studies were extracted and reviewed. The study has failed to identify any prospective satisfying inclusion/exclusion criteria RCT reporting on maxillary bone resorption. The number of maxillary complete denture relining incidences per patient was constantly increasing during the 10-year period. Maxillary complete denture remake incidences comprised 16-33 % of the number of patients followed during the 10-year period. Comparing patient satisfaction with upper dentures at the baseline and after two years, no decrease in satisfaction was noticed. There is no evidence that maxillary ridge resorption is accelerated with certain types of two-implant supported mandibular overdenture attachments. Most common complication for the maxilla - prosthetic maintenance. There is a risk of decreased patient satisfaction with bar-supported mandibular overdenture. Further studies are needed to provide evidence for the maxillary complete denture outcome with two-implant supported mandibular overdentures.

  8. Influence of restorative materials on color of implant-supported single crowns in esthetic zone: A spectrophotometric evaluation

    M., Peng; W.-J., Zhao; M., Hosseini

    2017-01-01

    of the esthetic outcome of soft tissue around implant-supported single crowns in the anterior zone, and the crown color match score was used for subjective evaluation of the esthetic outcome of implant-supported restoration. ANOVA analysis was used to compare the differences among groups and Spearman correlation...

  9. Comparison of fixed implant-supported prostheses, removable implant-supported prostheses, and complete dentures: patient satisfaction and oral health-related quality of life.

    Oh, Sung-Hee; Kim, Younhee; Park, Joo-Yeon; Jung, Yea Ji; Kim, Seong-Kyun; Park, Sun-Young

    2016-02-01

    The purpose of this study was to compare patient satisfaction and oral health-related quality of life (OHRQoL) among fully edentulous patients treated with either fixed implant-supported prostheses (FP), removable implant-supported prostheses (RP), or complete dentures (CD). Eighty-six patients - 29 FP, 27 RP, and 30 CD patients - participated in this study. The survey was conducted using face-to-face interviews with a questionnaire that included a patient satisfaction scale and Oral Health Impact Profile (OHIP-14). We measured patient satisfaction after prosthetic treatments and OHRQoL before and after the treatments. After prosthetic treatments, OHRQoL increased in all three groups (P patient satisfaction and OHRQoL, and both groups showed greater improvement compared with the CD group. Specifically, the OHRQoL dimensions of functional limitation, physical pain, psychological discomfort, and psychological disability in the FP group, and functional limitation in the RP group, improved greatly in comparison with the CD group (P patient satisfaction than the CD treatment. Reliable information of OHRQoL and patient satisfaction helps experts and patients choose the best prosthetic treatment option. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Cross-pinning: the philosophy of retrievability applied practically to fixed, implant-supported prostheses.

    Gervais, M J; Hatzipanagiotis, P; Wilson, P R

    2008-03-01

    Biologic and technical complications are widely reported in the dental literature and often compromise the functional and/or aesthetic features of fixed, implant-supported prostheses. Managing complications without damaging or destroying a restoration is an obvious advantage of implant-based dentistry where the option of prosthetic retrievability is almost always available. The technique of cross-pinning uses a transverse screw to secure a prosthesis to a milled implant abutment, allowing prosthetic retrievability irrespective of dental implant alignment. This study presents guidelines for cross-pinning implant-supported prostheses based on resistance form, screw mechanics and natural tooth contours. The technical aspects of cross-pinning are also discussed using examples from four implant systems.

  11. Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses.

    Batista, Mauro; Bonachela, Wellington; Soares, Janir

    2008-06-01

    The extraction of teeth involves the elimination of extremely sensitive periodontal mechanoreceptors, which play an important role in oral sensory perception. The aim of this study was to evaluate the recovery of interocclusal sensory perception for micro-thickness in individuals with different types of implant-supported prostheses. Wearers of complete dentures (CDs) comprised the negative control group (group A, n=17). The experimental group consisted of wearers of prostheses supported by osseointegrated implants (Group B, n=29), which was subsequently divided into 4 subgroups: B(1) (n=5)--implant supported overdentures (ISO) occluding with CD; B(2) (n=6)--implant-supported fixed prostheses (ISFP) occluding with CD; B(3) (n=8)--wearers of maxillary and mandibular ISFP, and B(4) (n=10)--ISFP occluding with natural dentition (ND). Individuals with ND represented the positive control group (Group C, n=24). Aluminum foils measuring 10 microm, 24 microm, 30 microm, 50 microm, 80 microm, and 104 microm thickness were placed within the premolar area, adding up to 120 tests for each individual. The mean tactile thresholds of groups A, B1, B2, B3, B4, and C were 92 microm, 27 microm, 27 microm, 14 microm, 10 microm, and 10 microm, respectively. [Correction added after publication online 18 April 2008: in the preceding sentence 92 microm, 27 microm, 14 microm, 10 microm and 10 microm, was corrected to 92 microm, 27 microm, 27 microm, 14 microm, 10 microm and 10 microm]. The Kruskal-Wallis test revealed significant difference among groups (P<0.05). The Dunn test revealed that group A was statistically different from groups C, B(3), and B(4), and that B(1) and B(2) were statistically different from group C. Progressive recovery of osseoperception as a function of the combination of implant-supported prostheses could be observed. Moreover, ISO and/or ISFP combinations may similarly maximize the recovery of osseoperception.

  12. Rehabilitation with implant-supported overdentures in total edentulous patients: A review

    Martínez–Lage-Azorín, Juan F.; Segura-Andrés, Gustavo; Faus-López, Joan; Agustín-Panadero, Rubén

    2013-01-01

    Objectives: The main aim of this review article is to discuss implant-supported overdentures (ISOs) as treatment in edentulous patients. Besides, we will try to discuss among the different treatment options in such patients and to analyze their validity when ISOs are compared with other clinical modalities. At the same time, we will try to suggest clinical guidelines supported by current clinical studies. Material and methods: We performed a Medline search and review of pertinent articles on ...

  13. Clinical Evaluation of Implant-Supported Removable Partial Dentures With a Stress-Breaking Attachment.

    Suzuki, Yasunori; Kono, Kentaro; Shimpo, Hidemasa; Sato, Yohei; Ohkubo, Chikahiro

    2017-08-01

    The stress-breaking ball (SBB) attachment can distribute the occlusal force equally between the alveolar ridge and the implants. The purpose of this study was to evaluate the implant-supported distal extension removable partial dentures (RPDs) with SBB attachment in 10 patients who were partially edentulous. This randomized crossover study was designed to compare the function of RPDs with and without healing abutments and SBB attachments to support the posterior aspects of the RPDs. Mandibular jaw movements during mastication and the occlusal force and contact area were measured with a commercially available tracking device and pressure-sensitive sheets. Using a visual analog scale, 4 criteria-chewing, retention, stability, and comfort-were evaluated. All of the data obtained were analyzed using a 1-way analysis of variance (α = 0.05). There were no significant differences in either the mean time or the coefficient of variation among the SBB attachments and healing abutments of implant-supported removable partial dentures (ISRPDs) and conventional removable partial dentures (CRPDs). SBB attachments and healing abutments of ISRPDs had greater forces and contact areas than those of CRPDs with significant differences. For all criteria, patients preferred SBB attachments to healing abutments and CRPDs. The implant-supported distal extension RPDs with SBB attachment improved denture stability and patients' satisfaction.

  14. Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures

    Flanagan D

    2017-11-01

    Full Text Available Dennis Flanagan Private Practice, Willimantic, CT, USA Abstract: Implant-supported dental prostheses can be retained by a screw or cement. Implant-supported fixed partial dentures have a passive fit. A passive fit means there is an internal gap between the abutment surface and the intaglio of the retainer to insure that there is no lateral pressure on the supporting implants or friction upon seating of the prosthesis. This gap is filled with cement for retention of the prosthesis. Any lateral pressure may cause marginal bone loss or periimplantitis. Also, there is usually a microscopic gap at the margin of a crown retainer that exposes the cement to oral fluids. The solubility of zinc phosphate (ZOP cement is a definite liability due to the risk for cement dissolution. In fixed prostheses, the dissolution of the cement of one or more retainers would cause a transfer of the occlusal load to the retained unit(s. The resulting rotation and lifting of the cement-retained implants from occlusal and parafunctional loads could cause loss of osseointegration of the abutment-retained implant(s. ZOP cement may not be indicated for implant-supported fixed partial dentures or splints. Cement dissolution in single unit probably only involves re-cementation, if the patient does not swallow or aspirate the crown. Keywords: passive fit, retention, film thickness, fixed, marginal gap 

  15. Implant-supported titanium prostheses following augmentation procedures: a clinical report.

    Knabe, C; Hoffmeister, B

    2003-03-01

    This report describes a novel technique for fabricating retrievable implant-supported titanium (Ti) prostheses in patients requiring a comprehensive treatment plan involving the combined efforts of maxillofacial surgery and implant prosthodontics. Following bone graft reconstructive surgery and implant placement prosthetic treatment was initiated by inserting ITI-Octa abutments. An impression was made, and a framework was fabricated by fusing Ti-cast frameworks to prefabricated titanium copings by laser-welding. This was followed by veneering or fabrication of a removable denture with Ti metal re-enforcement. Favourable clinical results have been achieved using these screw-retained Ti implant-supported restorations for patients treated with reconstructive bone graft-surgery, with clinical observation periods ranging from three to four years. The present observations suggest that these screw-retained implant-supported Ti prostheses may be a meaningful contribution to implant prosthodontics, facilitating retrievable restorations of optimum biocompatibility, good marginal precision and with a good esthetic result. However, controlled clinical studies are needed to establish the long-term serviceability of these Ti restorations.

  16. Electromyographic evaluation of mastication and swallowing in elderly individuals with mandibular fixed implant-supported prostheses

    Giédre Berretin-Felix

    2008-04-01

    Full Text Available This study evaluated the effect of implant-supported oral rehabilitation in the mandible on the electromyographic activity during mastication and swallowing in edentulous elderly individuals. Fifteen patients aged more than 60 years were evaluated, being 10 females and 5 males. All patients were edentulous, wore removable complete dentures on both dental arches, and had the mandibular dentures replaced by implant-supported prostheses. All patients were submitted to electromyographic evaluation of the masseter, superior orbicularis oris muscles, and the submental muscles, before surgery and 3, 6 and 18 months postoperatively, using foods of different textures. The results obtained at the different periods were analyzed statistically by Kruskal-Wallis non-parametric test. Statistical analysis showed that only the masseter muscle had a significant loss in electromyographic activity (p<0.001, with a tendency of similar response for the submental muscles. Moreover, there was an increase in the activity of the orbicularis oris muscle during rubber chewing after treatment, yet without statistically significant difference. Mandibular fixed implant-supported prostheses in elderly individuals revealed a decrease in electromyographic amplitude for the masseter muscles during swallowing, which may indicate adaptation to new conditions of stability provided by fixation of the complete denture in the mandibular arch.

  17. Biting Force and Muscle Activity in Implant-Supported Single Mandibular Overdentures Opposing Fixed Maxillary Dentition.

    Al-Magaleh, Wafaʼa R; Abbas, Nadia A; Amer, Ashraf A; Abdelkader, Ann A; Bahgat, Basma

    2016-04-01

    This study aimed to investigate the relation between biting force and masticatory muscle activity in patients treated by 3 modalities of single mandibular dentures. Forty implants were placed in 10 patients with completely edentulous mandibles. The study was divided into 3 treatment stages. Initially, each patient received a conventional mandibular complete denture. At the second stage, 4 mandibular implants were placed and the denture was refitted to their abutments. Third stage comprised connecting the denture to the implants through ball attachments. During each treatment stage, maximum biting force and muscle activity were measured during maximum clenching and chewing of soft and hard food. Biting force demonstrated a statistically significant increase by time for the 3 treatment stages. The highest muscle activity was recorded for the conventional denture followed by the implant-supported overdenture without attachment, whereas the lowest values were recorded for the implant-supported overdenture with attachment. Biting force was related mainly to the quality of denture support. Muscle activity was higher in patients with conventional denture than with implant-supported prostheses (with or without attachments).

  18. Within-Subject Comparison of Maxillary Implant-Supported Overdentures with and without Palatal Coverage.

    Zembic, Anja; Tahmaseb, Ali; Wismeijer, Daniel

    2015-06-01

    The purpose of this study was to compare patient-reported outcomes for maxillary implant-supported overdentures with and without palatal coverage. Twenty-one maxillary edentulous patients (six women, 15 men) were included. In total, 42 implants were inserted in the anterior maxilla. All patients received implant-supported overdentures on two retentive anchors with palatal coverage for 2 months. Thereafter, patient satisfaction was assessed by means of questionnaires capturing the oral health impact profile (OHIP) on functional limitation, physical pain, psychological discomfort, physical, psychological and social disability, and handicap. Additionally, cleaning ability, general satisfaction, speech, comfort, esthetics, stability, and chewing ability were rated. Subsequently, palatal coverage was reduced, and the patients wore the overdentures for another 2 months. Patient satisfaction was obtained in the same way as above, and the evaluated parameters were compared for the two overdenture designs. There were no significant differences between implant-supported overdentures with and without palatal coverage for any of the OHIP domains. The evaluation of additional parameters revealed significantly higher patient satisfaction for esthetics (mean difference 8.8 mm ± 24.6) and taste (mean difference 28.4 mm ± 29.9) without palatal coverage, p overdentures supported by two implants were equally satisfactory with and without palatal coverage. © 2013 Wiley Periodicals, Inc.

  19. Fracture Strength and Failure Mode of Maxillary Implant-Supported Provisional Single Crowns : A Comparison of Composite Resin Crowns Fabricated Directly Over PEEK Abutments and Solid Titanium Abutments

    Santing, H.J.; Meijer, Henny J.A.; Raghoebar, G.M.; Ozcan, M.

    2012-01-01

    Background: Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. Purpose: The objectives of this

  20. Superstructure optimization of biodiesel production from microalgal biomass

    Rizwan, Muhammad; Lee, Jay H.; Gani, Rafiqul

    2013-01-01

    In this study, we propose a mixed integer nonlinear programming (MINLP) model for superstructure based optimization of biodiesel production from microalgal biomass. The proposed superstructure includes a number of major processing steps for the production of biodiesel from microalgal biomass...... for the production of biodiesel from microalgae. The proposed methodology is tested by implementing on a specific case study. The MINLP model is implemented and solved in GAMS using a database built in Excel. The results from the optimization are analyzed and their significances are discussed....

  1. Superstructure for high current applications in superconducting linear accelerators

    Sekutowicz, Jacek [Elbchaussee, DE; Kneisel, Peter [Williamsburg, VA

    2008-03-18

    A superstructure for accelerating charged particles at relativistic speeds. The superstructure consists of two weakly coupled multi-cell subunits equipped with HOM couplers. A beam pipe connects the subunits and an HOM damper is included at the entrance and the exit of each of the subunits. A coupling device feeds rf power into the subunits. The subunits are constructed of niobium and maintained at cryogenic temperatures. The length of the beam pipe between the subunits is selected to provide synchronism between particles and rf fields in both subunits.

  2. Clinical Performance of One-Piece, Screw-Retained Implant Crowns Based on Hand-Veneered CAD/CAM Zirconia Abutments After a Mean Follow-up Period of 2.3 Years.

    Schnider, Nicole; Forrer, Fiona Alena; Brägger, Urs; Hicklin, Stefan Paul

    The aim of this study was to evaluate the clinical performance of one-piece, screw-retained implant crowns based on hand-veneered computer-aided design/computer-aided manufacture (CAD/CAM) zirconium dioxide abutments with a crossfit connection at least 1 year after insertion of the crown. Consecutive patients who had received at least one Straumann bone level implant and one-piece, screw-retained implant crowns fabricated with CARES zirconium dioxide abutments were reexamined. Patient satisfaction, occlusal and peri-implant parameters, mechanical and biologic complications, radiologic parameters, and esthetics were recorded. A total of 50 implant crowns in the anterior and premolar region were examined in 41 patients. The follow-up period of the definitive reconstructions ranged from 1.1 to 3.8 years. No technical and no biologic complications had occurred. At the reexamination, 100% of the implants and reconstructions were in situ. Radiographic evaluation revealed a mean distance from the implant shoulder to the first visible bone-to-implant contact of 0.06 mm at the follow-up examination. Screw-retained crowns based on veneered CAD/CAM zirconium dioxide abutments with a crossfit connection seem to be a promising way to replace missing teeth in the anterior and premolar region. In the short term, neither failures of components nor complications were noted, and the clinical and radiographic data revealed stable hard and soft tissue conditions.

  3. Masseter muscle fatigue during sustained clenching in subjects with complete dentures, implant-supported prostheses, and natural teeth.

    Jacobs, R; van Steenberghe, D

    1993-03-01

    A sustained submaximal (50%) clenching effort was performed in four patient groups to establish whether implant-supported prosthetic reconstructions influence myoelectrical signal parameters. The first group consisted of patients with natural teeth in both jaws. The other three groups consisted of patients who were edentulous in both jaws: one group had complete dentures; one had an overdenture in the mandible on two implants connected by a bar; and the third had an implant-supported fixed prosthesis in either the maxilla or the mandible. Surface electromyography indicated an increased myoelectrical output level that paralleled a higher bite force level for implant-supported reconstructions compared with complete dentures. Power spectrum analysis revealed a downward shift of the mean power frequency during sustained clenching in all groups except the implant-supported fixed prosthesis. The absence of a spectral shift in the latter group probably reflected a fear of biting too hard and fracturing the prosthesis.

  4. Retrofitting the Superstructure of a Large Passenger Ship Using Composites – A Demonstration

    Karatzas, Vasileios; Hjørnet, Niels; Berggreen, Christian

    2015-01-01

    In this work, the superstructure of a RoPax ferry has been redesigned using composite materials and the new design has been compared to the existing steel superstructure from a structural perspective. To this end, FE models have been developed and the superstructures have been subjected to loadin...

  5. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position.

    Jensen, Charlotte; Raghoebar, Gerry M; Kerdijk, Wouter; Meijer, Henny J A; Cune, Marco S

    2016-12-01

    To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Thirty subjects with a bilateral unbounded posterior saddle received 2 PM and 2M implants. A new RPD was placed. Implant support was provided 3 months later. Two PM implants supported the RPD. After 3 months the 2M implants were used or vice versa. Outcome measures included oral health related quality of life (OHIP-NL49), general health status (SF-36), contentment assessed on a Visual Analogue Scale (VAS) and the number of hours that the RPD was worn. Data were collected prior to treatment, 3 months after having functioned with a new RPD and after 3 and 6 months with implant support. Finally, patients expressed their preferred implant position. The general health status (SF-36) was not influenced. OHIP-NL49 values and mean wearing-time were statistical significantly more favorable for ISRPD's, regardless of the implant position. Per day, the ISRPD's were worn 2-3h more than the unsupported new RPD. Patients' expectations were met as the VAS-scores of anticipated and realized contentment did not reach a statistical significant level (p>0.05). VAS scores for ISRPD's with M implant support were higher than for PM implant support. Finally, 56.7% of subjects preferred the M implant support, 13.3% expressed no preference and 30% opted for PM implant support. Mandibular implant support favorably influences oral health related patient-based outcome measures in patients with a bilateral free-ending situation. The majority of patients prefer the implant support to be in the molar region. Patients with a bilateral free-ending situation in the mandible opposed by a maxillary denture benefit from implant support to their mandibular removable partial denture. Most patients prefer this support to be in the molar region. Copyright © 2016

  6. The impact on bone tissues of immediate implant-supported mandibular overdentures with cusped and cuspless teeth

    Khalid A. Arafa

    2016-01-01

    Objectives: To examine the effects on bone tissues of immediate implant-supported mandibular overdentures with cusped or cuspless teeth. Methods: A randomized controlled trial was conducted at the Dental Clinic, Faculty of Dentistry, Al-Azhar University, Assiut Branch, Egypt, over a 12-month period from September 2013 to September 2014. Twenty patients were treated with immediate implant-supported overdentures: one group received overdentures with cusped teeth, and the other group receive...

  7. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA.

    Qamheya, Ala Hassan A; Yeniyol, Sinem; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient.

  8. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA

    Ala Hassan A. Qamheya

    2015-01-01

    Full Text Available Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC material in teeth construction to rehabilitate a complete denture wearer patient.

  9. Superstructure-based optimization of biorefinery networks: Production of biodiesel

    Bertran, Maria-Ona; Orsi, Albert; Gani, Rafiqul

    2015-01-01

    through a practical case study for the production biodiesel from a variety of feedstock. The different biorefinery processing alternatives are represented in a superstructure and the associated data is collected and stored in a database. Once a specific biorefinery synthesis problem is formulated...

  10. Bar versus ball attachments for implant-supported overdentures in complete edentulism: A systematic review.

    Anas El-Wegoud, Marwah; Fayyad, Ahmed; Kaddah, Amal; Nabhan, Ashraf

    2018-04-01

    Implant-supported overdenture is one of the most predictable treatment options used in complete edentulism. However, differences have been reported between bar and ball attachments used to retain overdentures in terms of patient satisfaction and prosthesis retention. The purpose of this study is to compare the effectiveness of bar and ball attachments for conventionally loaded implant-supported overdentures in completely edentulous patients to improve patient satisfaction and prosthesis retention. We conducted the review according to the Cochrane methods and following MECIR standards. We searched Cochrane Oral Health Group Trial register, Cochrane Central Register of Controlled Trials, MEDLINE, and the WHO ICTRP (March 31, 2017). Two review authors assessed trials for inclusion and risk of bias, extracted data, and checked for accuracy. We have expressed results as risk ratio or mean differences, together with their 95% confidence intervals. We included 10 trials (465 participants). After 5 y, one trial reported higher patient satisfaction when bar attachment was used (MD 1.30, 95% CI 0.20-2.40), and reported no difference between both systems in prosthesis retention (MD -0.90, 95% CI -1.90 to 0.10). Two trials reported no implant failures after 1 and 5 y in both attachments. Downgrading of evidence was based on the unclear risk of bias of included studies and the wide CI crossing the line of no effect. There is insufficient evidence to support bar or ball attachment to be used with implant-supported overdentures in completely edentulous patients to improve patient satisfaction and prosthesis retention (PROSPERO 2014:CRD42014014594). © 2017 Wiley Periodicals, Inc.

  11. Magnet-retained implant-supported overdentures: review and 1-year clinical report.

    Ceruti, Paola; Bryant, S Ross; Lee, Jun-Ho; MacEntee, Michael I

    2010-01-01

    Open-field aluminum-nickle-cobalt magnets have been used in prosthodontics for many years, but success has been limited because these magnets are susceptible to corrosion by the saliva and because their retentive force is weak relative to the initial retention offered by mechanical attachments. More recently, magnets have been made from alloys of the rare earth elements samarium and neodymium, which provide stronger magnetic force per unit size. In addition, a new generation of laser-welded containers has improved protection from salivary corrosion. The current resurgence of interest in this type of attachment appears justified because, unlike mechanical attachments, magnets have potential for unlimited durability and might therefore be superior to mechanical ball or bar attachments for the retention of removable prostheses on implants. To date, no long-term prospective trials have been conducted to confirm the clinical durability of this new generation of magnets for retaining dentures on either teeth or implants. The aim of this study was to document initial clinical experiences and levels of satisfaction among edentulous patients treated with mandibular implant-supported overdentures retained using a new generation of rare-earth magnetic attachments. At the outset, all but one of the 17 patients had had several years of experience with implant-supported overdentures. During the first year, the mean overall satisfaction among these 17 patients increased from less than 70 to over 90 out of 100 (standardized visual analogue scale). No unusual difficulties were encountered in rendering the treatment or maintaining the attachments. This report offers preliminary evidence of the excellent potential of these magnets for retaining mandibular implant-supported overdentures.

  12. Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: a preliminary clinical and radiologic report.

    Bergkvist, Göran; Sahlholm, Sten; Karlsson, Ulf; Nilner, Krister; Lindh, Christina

    2005-01-01

    To evaluate the survival rate of immediately loaded ITI sand-blasted, large-grit, acid-etched (SLA) solid-screw dental implants in the edentulous maxilla after 8 months of loading. Twenty-eight patients (mean age 63 years) with edentulous maxillae each received 6 implants and 1 implant-supported fixed provisional prosthesis within 24 hours after surgery. After a mean healing time of 15 weeks, the patient received a definitive, screw-retained, implant-supported fixed prosthesis. A total of 168 implants were placed. Clinical parameters were registered after 1 month of loading with the implant-supported fixed prostheses as well as 8 months after implant placement. Radiologic examinations and assessments were made at implant placement and after 8 months. The mean marginal bone level at implant placement was 1.6 mm (range 0 to 5.1; SD 1.1) apical of the reference point (the implant shoulder). The mean marginal bone level at the 8-month follow-up was 3.2 mm (range 0.4 to 5.9; SD 1.1) apical of the reference point. Three implants failed during the healing period. The improved results in the present study might be a result of the positive effect of splinting the implants immediately after placement. ITI SLA solid-screw implants immediately loaded (ie, loaded within 24 hours of placement) and supporting fixed prostheses had successful survival rates after 8 months. The present results constitute a solid baseline for future follow-up studies.

  13. Evaluation of Satisfaction Level in Patients With Mandibular Implant Supported Overdentures

    Masoumeh khoshhal

    2016-01-01

    Full Text Available Background Implant-supported overdentures could have many benefits for patients, especially in the lower jaws. As a matter of fact, the most common reason for prescribing mandibular overdenture is dissatisfaction of patients with mandibular dentures usually because of a lack of retention, stability and function and speech difficulties. On the other hand, patients' expectations of overdenture treatments are their main disadvantage. Objectives The aim of this study was to evaluate the satisfaction of patients who had received mandibular implant supported overdenture treatment with different number of implants. Patients and Methods This study was a descriptive cross-sectional study. Twenty-five patients with a mean age of 62.7 years who had received mandibular implant supported overdenture treatment at the dental school of Hamadan University of Medical Sciences were enrolled. Among these patients, six had overdentures supported by one implant, nine had overdentures supported by two implants, two had overdentures supported by three implants, five had overdentures supported by four implants and three had overdentures supported by five implants. The visual analogue scale (VAS questionnaire was used to evaluate the general satisfaction, comfort, esthetic, fitness, satisfaction of chewing and social communication, and the data was analyzed by the analysis of variance (ANOVA test. Results All patients in all five groups were satisfied with their overdentures; however there was no significant relationship between the number of implants and fitness (P = 0.446, esthetic (P = 0.843, comfort (P = 0.805, satisfaction of chewing (P = 0.133, social communication (P = 0.322 and general satisfaction (P = 0.493. Conclusions There was no difference in satisfaction level of patients who had received mandibular overdentures with different number of implants.

  14. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature.

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-06-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case.

  15. Zygoma Implant-Supported Prosthetic Rehabilitation of a Patient After Bilateral Maxillectomy.

    Celakil, Tamer; Ayvalioglu, Demet Cagil; Sancakli, Erkan; Atalay, Belir; Doganay, Ozge; Kayhan, Kivanc Bektas

    2015-10-01

    Maxillectomy defects may vary from localized to extensive soft and hard tissue loss. In addition to physical and psychologic damages, functional and aesthetic aspects must be restored. This clinical report describes the rehabilitation of a patient with a zygoma implant-supported obturator prosthesis caused by a subtotal bilateral maxillectomy due to a squamous oral cell carcinoma. Prosthetic rehabilitation of this patient was performed after zygoma implant surgery. A maxillary obturator prosthesis supported by 2 osseointegrated zygoma implants was fabricated. Despite limited mouth opening and anatomic deficiencies, the patient's aesthetic and functional demands were fulfilled.

  16. Retention system for implant-supported dentures used by brazilian dentists who work in implant dentistry

    Saturnino Aparecido Ramalho; Fábio Pontes Dantas

    2010-01-01

    Objective: To provide the dentists with support in the choice of the cement or screw type of retention for implant-supported dentures, according to the patient’s problem. Methods: An opinion questionnaire was applied to a sample of 468 participants, all dentists working in the field of Implant Dentistry, of whom 272 (58.1%) participated in the 4th International Congress of Osseointegration of APCD, held in São Paulo (SP) from 6 to 9 May 2004, 119 (25.4%) participated in the 2nd International ...

  17. Terminal Posterior Tilted Implants Planned as a Sinus Graft Alternative for Fixed Full-Arch Implant-Supported Maxillary Restoration: A Case Series with 10- to 19-Year Results on 44 Consecutive Patients Presenting for Routine Maintenance.

    Fortin, Yvan; Sullivan, Richard M

    2017-02-01

    Posterior maxillary tilted implants are gaining prevalence as an alternative to sinus grafts supporting fixed maxillary restorations. This paper reports long-term results after loading using this technique. Consecutive patients presenting for either routine hygiene maintenance or unplanned emergency care who had received tilted implants as a sinus graft alternative to support fixed fully implant-supported restoration of an edentulous maxilla and were followed for a minimum of 10 years from initial implant placement were included in this evaluation. Forty-four patients were identified: 40 with bilateral tilted implants and 4 with one tilted and one axial posterior implant. Eight patients received one-piece fixed porcelain-to-gold screw-retained restorations, and thirty-six patients received a fully implant-supported patient-removable Marius Bridge. Seventy-nine out of 84 originally loaded posterior tilted implants survived a minimum of 10 years loading; one tilted implant was lost at 10 years. Eight additional posterior implants were placed for either these lost tilted posterior implants or as proactive supplemental support; one of these replacement tilted implants survived for at least 10 years and is included in the data. All patients have maintained continuous fixed function throughout the follow-up period. Forty-one out of 44 patients continue with the original restoration, 33 without modification or removal of the fixed restoration or implant-connecting bar. One porcelain-to-gold and seven Marius Bridges had framework modifications to accommodate additional implants; 3 Marius Bridge restorations were replaced with a newer generation. Within the limits of this retrospective study, the results show that continuous fixed function of fully implant-supported maxillary restorations using posterior tilted implants in terminal positions of support as a sinus graft alternative combined with axial anterior implants is possible over a prolonged period. Loss of a posterior

  18. Implant-supported Oral Rehabilitation in Child with Ectodermal Dysplasia - 4-year Follow-up.

    Cezária Triches, Thaisa; Ximenes, Marcos; Oliveira de Souza, João Gustavo; Rodrigues Lopes Pereira Neto, Armando; Cardoso, Antônio Carlos; Bolan, Michele

    2017-01-01

    Ectodermal dysplasia (ED) is an anomaly determined by genetic factors that alter ectodermal structures such as skin, hair, nails, glands, and teeth. Children affected by this condition require extensive, comprehensive, and multidisciplinary treatment. An 8-year-old female patient visited the Dentistry Clinic of the Federal University of Santa Catarina with the chief complaint of multiple missing teeth. The mother reported that the patient had ED. Clinical and radiographic examination revealed the congenital absence of several primary and permanent teeth and tooth germs. Subsequent oral rehabilitation comprised the application of a maxillary denture and mandibular implant-supported fixed prosthesis. The child was also supplied with a wig for further enhancement of esthetics aimed at improving her emotional wellbeing. Psychological follow-up and speech therapy were also provided. After 4 years of follow-up, implant-supported oral rehabilitation has proved to be a satisfactory treatment option, allowing restoration of masticatory, phonetic, and esthetic function, as well as an improvement in the patient's self-esteem and social wellbeing.

  19. Electromyographic evaluation of implant-supported prostheses in hemimandibulectomy-reconstructed patients.

    Dellavia, Claudia; Romeo, Eugenio; Ghisolfi, Marco; Chiapasco, Matteo; Sforza, Chiarella; Ferrario, Virgilio F

    2007-06-01

    To assess the clinical conditions, patient's satisfaction and functional outcomes in oral neoplasia patients with hemimandibulectomy, bone reconstruction and implant-supported prosthesis. Twelve patients after mandibular resection (with and without condyle), reconstruction and successful fixed implant-supported prosthesis rehabilitation were examined. Patients underwent clinical evaluation and filled in a questionnaire about their satisfaction toward oral functions. Surface electromyography (EMG) of the masticatory muscles was performed during a 15-s unilateral gum chewing test. EMG potentials were standardized as percentage of a maximum clench on cotton rolls and compared with reference data obtained from 20 healthy subjects. Excellent clinical and radiological parameters were found. Patients stated a decreased post-rehabilitation satisfaction toward mastication and phonetics, but an increased attention to oral care. Only patients with condylar resection reported augmented esthetic scores. In both the resected and the remaining sides, chewing frequency was higher in the patients than in the reference group (Wilcoxon's rank-sum test, Pchewing were more variable in the reconstructed patients than in control subjects; the difference was significant only in the non-operated side (P<0.01). Post-rehabilitation median scores of the questionnaire indicated a positive judgment of the treatment. EMG analysis showed that functional recovery in hemimandibulectomy patients was satisfactory, although some alterations were observed in the non-operated side of mastication.

  20. Various Techniques to Increase Keratinized Tissue for Implant Supported Overdentures: Retrospective Case Series

    Ahmed Elkhaweldi

    2015-01-01

    Full Text Available Purpose. The purpose of this retrospective case series is to describe and compare different surgical techniques that can be utilized to augment the keratinized soft tissue around implant-supported overdentures. Materials and Methods. The data set was extracted as deidentified information from the routine treatment of patients at the Ashman Department of Periodontology and Implant Dentistry at New York University College of Dentistry. Eight edentulous patients were selected to be included in this study. Patients were treated for lack of keratinized tissue prior to implant placement, during the second stage surgery, and after delivery of the final prosthesis. Results. All 8 patients in this study were wearing a complete maxillary and/or mandibular denture for at least a year before the time of the surgery. One of the following surgical techniques was utilized to increase the amount of keratinized tissue: apically positioned flap (APF, pedicle graft (PG, connective tissue graft (CTG, or free gingival graft (FGG. Conclusions. The amount of keratinized tissue should be taken into consideration when planning for implant-supported overdentures. The apical repositioning flap is an effective approach to increase the width of keratinized tissue prior to the implant placement.

  1. Evaluation of stress distribution characteristics on various bar designs of three-implant-supported mandibular overdentures

    Emre Tokar

    2017-01-01

    Full Text Available Objective: Implant-supported-overdentures, instead of conventional complete dentures, are frequently recommended to rehabilitate patients having edentulous mandible. The aim of this study was to evaluate the stress distribution characteristics of mandibular implant-supported overdentures with four different bar attachment designs. Materials and Method: A photoelastic mandibular model with three implants (3.75 mm - 13 mm placed at the interforaminal region was generated from a cast of an edentulous mandible. Four mandibular bar overdenture designs were fabricated: bar-clip, bar-galvano, bar-locator, and bar-ceka. Axial vertical loads (135 N were applied to the central fossa of the right first molar area for each overdenture design. Stress concentrations were recorded photographically and analyzed visually. Results: The tested bar attachment designs revealed low and moderate stress levels. The lowest stress was observed with the bar-clip design, followed by bar-locator, bar-ceka, and bar-galvano designs. Conclusion: The loads were distributed to all of the implants. Studied designs experienced moderate stress levels around the loaded side implant. Bars with distally placed stud attachments and surface treatment with electroforming seems to increase stress levels around the implants.

  2. SELF-ORGANIZATION OF LEAD SULFIDE QUANTUM DOTS INTO SUPERSTRUCTURES

    Elena V. Ushakova

    2014-11-01

    Full Text Available The method of X-ray structural analysis (X-ray scattering at small angles is used to show that the structures obtained by self-organization on a substrate of lead sulfide (PbS quantum dots are ordered arrays. Self-organization of quantum dots occurs at slow evaporation of solvent from a cuvette. The cuvette is a thin layer of mica with teflon ring on it. The positions of peaks in SAXS pattern are used to calculate crystal lattice of obtained ordered structures. Such structures have a primitive orthorhombic crystal lattice. Calculated lattice parameters are: a = 21,1 (nm; b = 36,2 (nm; c = 62,5 (nm. Dimensions of structures are tens of micrometers. The spectral properties of PbS QDs superstructures and kinetic parameters of their luminescence are investigated. Absorption band of superstructures is broadened as compared to the absorption band of the quantum dots in solution; the luminescence band is slightly shifted to the red region of the spectrum, while its bandwidth is not changed much. Luminescence lifetime of obtained structures has been significantly decreased in comparison with the isolated quantum dots in solution, but remained the same for the lead sulfide quantum dots close-packed ensembles. Such superstructures can be used to produce solar cells with improved characteristics.

  3. Mach Number effects on turbulent superstructures in wall bounded flows

    Kaehler, Christian J.; Bross, Matthew; Scharnowski, Sven

    2017-11-01

    Planer and three-dimensional flow field measurements along a flat plat boundary layer in the Trisonic Wind Tunnel Munich (TWM) are examined with the aim to characterize the scaling, spatial organization, and topology of large scale turbulent superstructures in compressible flow. This facility is ideal for this investigation as the ratio of boundary layer thickness to test section spanwise extent ratio is around 1/25, ensuring minimal sidewall and corner effects on turbulent structures in the center of the test section. A major difficulty in the experimental investigation of large scale features is the mutual size of the superstructures which can extend over many boundary layer thicknesses. Using multiple PIV systems, it was possible to capture the full spatial extent of large-scale structures over a range of Mach numbers from Ma = 0.3 - 3. To calculate the average large-scale structure length and spacing, the acquired vector fields were analyzed by statistical multi-point methods that show large scale structures with a correlation length of around 10 boundary layer thicknesses over the range of Mach numbers investigated. Furthermore, the average spacing between high and low momentum structures is on the order of a boundary layer thicknesses. This work is supported by the Priority Programme SPP 1881 Turbulent Superstructures of the Deutsche Forschungsgemeinschaft.

  4. Mandibular implant-supported overdentures: attachment systems, and number and locations of implants--Part I.

    Warreth, Abdulhadi; Alkadhimi, Aslam Fadel; Sultan, Ahmed; Byrne, Caroline; Woods, Edel

    2015-01-01

    The use of dental implants in replacing missing teeth is an integral part of restorative dental treatment. Use of conventional complete dentures is associated with several problems such as lack of denture stability, support and retention. However, when mandibular complete dentures were used with two or more implants, an improvement in the patients' psychological and social well-being could be seen. There is general consensus that removable implant-supported overdentures (RISOs) with two implants should be considered as the first-choice standard of care for an edentulous mandible. This treatment option necessitates the use of attachment systems that connect the complete denture to the implant. Nevertheless, each attachment system has its inherent advantages and disadvantages, which should be considered when choosing a system. The first part of this article provides an overview on options available to restore the mandibular edentulous arch with dental implants. Different types of attachment systems, their features and drawbacks are also reviewed.

  5. Implant supported prosthesis in an edentulous boy with Hypohidrotic Ectodermal Dysplasia - "A happy boy"

    Gjørup, Hans; Nyhuus, Lone; Buhl, Jytte

    2009-01-01

    region. 3. At the age of 10 years a new set of dentures were made. This time the upper denture was made as an overdenture supported and retained by 4 implants and a Dolder bar. The surgical procedure included bone grafting from the anterior ramus mandibulae. The boy's subjective judgement of his oral......Implant supported prosthesis in an edentulous boy with Hypohidrotic Ectodermal Dysplasia - "A happy boy". Authors; Gjoerup,H1; Nyhuus,L2; Buhl,J3. 1) Center for Oral Health in Rare Conditions, Aarhus University Hospital 2) Prosthodontic Department, the Dental School, Aarhus University 3) Department...... by the patient and his family. Case presentation The boy was untreated until the age of 5 years. His oral functions were compromised in relation to speech and psychosocial aspects. In the following 6 years, he underwent prosthodontic treatment in three phases. 1. At the age of 5 years a set of complete dentures...

  6. Telescopic crowns as attachments for implant supported restorations: a case series.

    Hoffmann, Oliver; Beaumont, Christian; Tatakis, Dimitris N; Zafiropoulos, Gregory-George

    2006-01-01

    The use of dental implants to support mandibular or maxillary overdentures is a widely used treatment modality. Advantages are an increase in retention, an increase in chewing ability, and easy access for oral hygiene procedures. While telescopic and conical crowns have been used for decades to connect natural teeth to overdentures, not many cases have been reported in the literature of telescopic crowns placed on implants to support overdentures. This article describes 7 patients with overdentures supported by telescopic crowns who received 65 implants (ITI Straumann). The cases presented in this report have been in function for up to 4.5 years. During that time no adverse events were reported. The use of telescopic crowns as attachments for implant-supported overdentures may be a viable treatment option.

  7. Zirconia- versus metal-based, implant-supported abutments and crowns

    Hosseini, Mandana

    , the selection of restoration materials should be based on proper optical characteristics in addition to biocompatibility and sufficient strength of materials. Abutments and crowns based on zirconia are one of the most recent alternatives to metal abutments and metal-ceramic crowns. To date, only few comparative...... and to estimate long-term biomechanical results of zirconia-based versus metal-based restorations. The aim of study I was to analyse the mode of fracture and number of cyclic loadings until veneering fracture of zirconia-based all-ceramic restorations compared to metal-ceramic restorations. The aim of study II...... was to test the reliability and validity of six aesthetic parameters used at the Copenhagen Dental School to assess the aesthetic outcome of implant-supported restorations. The aims of study III and IV were to compare the influence of different abutment and crown materials on biological, biomechanical...

  8. Prosthetic Complications and Maintenance Requirements in Locator-attached Implant-Supported Overdentures: A Retrospective Study.

    Engelhardt, Frank; Zeman, Florian; Behr, Michael; Hahmel, Sebastian

    2016-03-01

    Retrospective data of 32 patients supplied with implant-supported and Locator-attached overdentures were screened for prosthetic complications and maintenance requirements, which were recorded and statistically analyzed. Mean observation time was 4.78 ± 1.72) years. Loss of retention was the most frequently observed event (n = 22). Damage and exchange of the insert holders (n = 4) and loosening of locator attachments (n = 2) and fracture of the insert holder (n = 2) were uncommon events; no loss of locator attachments was observed. Loss of retention in Locator-attached overdentures is frequent; correlating patient-specific parameters with prosthetic complications is necessary to define recommendations for the use of Locator attachments.

  9. The role of welding techniques in the biomechanical behavior of implant-supported prostheses.

    Rodrigues, Sabrina Alessandra; Presotto, Anna Gabriella Camacho; Barão, Valentim Adelino Ricardo; Consani, Rafael Leonardo Xediek; Nóbilo, Mauro Antônio Arruda; Mesquita, Marcelo Ferraz

    2017-09-01

    This in vitro study investigated the role of welding techniques of implant-supported prostheses in the 2D and 3D marginal misfits of prosthetic frameworks, strain induced on the mini abutment, and detorque of prosthetic screws. The correlations between the analyzed variables were also investigated. Frameworks were cast in commercially pure titanium (cp-Ti). A marginal misfit of 200μm was simulated in the working models (control group) (n=20). The 2D marginal misfit was analyzed according to the single-screw test protocol using a precision optical microscope. The 3D marginal misfit was performed by X-ray microtomography. Strain gauge analysis was performed to investigate the strain induced on the mini abutment. A digital torque meter was used for analysis of the detorque and the mean value was calculated for each framework. Afterwards, the frameworks were divided into two experimental groups (n=10): Laser (L) and TIG (T). The welding techniques were performed according to the following parameters: L (390V/9ms); T (36A/60ms). The L and T groups were reevaluated according to the marginal misfit, strain, and detorque. The results were submitted to one-way ANOVA followed by Tukey's HSD test and Person correlation analysis (α=0.05). Welding techniques statistically reduced the 2D and 3D marginal misfits of prosthetic frameworks (p0.05). Positive correlations were observed between 2D and 3D marginal misfit reading methods (r=0.943, pwelding techniques improved the biomechanical behavior of the implant-supported system. TIG can be an acceptable and affordable technique to reduce the misfit of 3-unit Ti frameworks. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Cost-effectiveness of implant-supported mandibular removable partial dentures.

    Jensen, Charlotte; Ross, Jamila; Feenstra, Talitha L; Raghoebar, Gerry M; Speksnijder, Caroline; Meijer, Henny J A; Cune, Marco S

    2017-05-01

    The aim of this study was to conduct a cost-effectiveness analysis comparing conventional removable partial dentures (RPDs) and implant-supported RPDs (ISRPDs) treatment in patients with an edentulous maxilla and a bilateral free-ending situation in the mandible. Thirty subjects were included. A new RPD was made and implant support was provided 3 months later. Treatment costs (opportunity costs and costs based on tariffs) were calculated. Treatment effect was expressed by means of the Dutch Oral Health Impact Profile questionnaire (OHIP-NL49), a chewing ability test (Mixing Ability Index, MAI) and a short-form health survey measuring perceived general health (SF-36), which was subsequently converted into quality-adjusted-life-years (QALYs). The incremental cost-effectiveness ratio (ICER) was the primary outcome measure of cost-effectiveness, comparing both treatment strategies. The mean total opportunity costs were €981 (95% CI €971-€991) for the RPD treatment and €2.480 (95% CI €2.461-€2.500) for the ISRPD treatment. The total costs derived from the national tariff structure were €850 for the RPD treatment and €2.610 for the ISRPD treatment. The ICER for OHIP-NL49 and MAI using the opportunity costs was €80 and €786, respectively. When using the tariff structure, corresponding ICERs were €94 and €921. The effect of supporting an RPD with implants when expressed in QALYs was negligible; hence an ICER was not determined. It is concluded that depending on the choice of outcome measure and monetary threshold, supporting an RPD with implants is cost-effective when payers are willing to pay more than €80 per OHIP point gained. Per MAI point gained, an additional €786 has to be invested. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Fatigue Fracture Strength of Implant-Supported Full Contour Zirconia and Metal Ceramic Fixed Partial Dentures

    Fariborz Vafaee

    2017-10-01

    Full Text Available Objectives: Zirconia restorations have been suggested as a more durable and more appealing alternative to metal restorations. However, their mechanical properties may be negatively affected by fatigue due to superficial stresses or low temperature degradation. This study aimed to assess the fatigue fracture strength of three-unit implant-supported full contour zirconia and pre-sintered cobalt-chromium (Co-Cr alloy posterior fixed partial dentures (FPDs.Materials and Methods: In this in-vitro experimental study, 28 posterior three-unit implant-supported FPDs were fabricated of full contour zirconia and pre-sintered Co-Cr alloy, and were cemented on implant abutments. To simulate the oral environment, FPDs were subjected to 10,000 thermal cycles between 5-55°C for 30 seconds, and were then transferred to a chewing simulator (100,000 cycles, 50 N, 0.5 Hz. Afterwards, fatigue fracture strength was measured using a universal testing machine. Data were analyzed by Mann-Whitney U test.Results: The mean and standard deviation of fracture strength were 2108.6±440.1 N in full contour zirconia, and 3499.9±1106.5 N in pre-sintered Co-Cr alloy. According to Mann- Whitney U test, the difference in this respect was statistically significant between the two groups (P=0.007.Conclusions: Since the fracture strength values obtained in the two groups were significantly higher than the maximum mean masticatory load in the oral environment, both materials can be used for fabrication of posterior three-unit FPDs, depending on the esthetic demands of patients.

  12. Retentiveness of implant-supported metal copings using different luting agents

    Farahnaz Nejatidanesh

    2012-01-01

    Full Text Available Background: With regard to potential retrievability of cement-retained implant restorations, the retentive strength of the luting agents is critical. The aim of this study was to evaluate the retention values of implant-supported metal copings using different luting agents. Materials and Methods: Twenty ITI implant analogs and solid abutments of 5.5-mm height were embedded vertically in autopolymerizing acrylic resin blocks. Metal copings with a loop on the occlusal surface were fabricated using base metal alloy (Rexillium III. The copings were luted using eight cements with different retention mechanisms (Panavia F2.0, Fuji Plus, Fleck′s, Poly F, Fuji I, Temp Bond, GC-free eugenol, and TempSpan under static load of 5 kg (n=10. All specimens were incubated at 37°C for 24 hours, conditioned in artificial saliva for 7 days and thermocycled for 5000 cycles (5-55°C. The dislodging force was measured using a universal testing machine at a crosshead speed of 5 mm/min. Statistical analyses were performed using Kruskal-Wallis (α=0.05 and Mann-Whitney tests with Bonferroni correction (α=0.001. Results: Fuji Plus and TempSpan had the highest and the least mean retentive strength, respectively (320.97±161.47, 3.39±2.33. There was no significant difference between Fuji Plus, Fleck′s, Ploy F, and Panavia F2.0. These cements were superior to provisional cements and Fuji I (P<0.001 which showed statistically same retentive strength. Conclusion: Within the conditions of this study, the resin modified glass ionomer, zinc phosphate, zinc polycarboxylate, and Panavia F2.0 had statistically the same retentive quality and are recommended for definitive cementation of single implant-supported restorations. The provisional cements and glass ionomer may allow retrievability of these restorations.

  13. Maxillary Implant-Supported Fixed Prosthesis: A Survey of Reviews and Key Variables for Treatment Planning.

    Gallucci, German O; Avrampou, Marianna; Taylor, James C; Elpers, Julie; Thalji, Ghadeer; Cooper, Lyndon F

    2016-01-01

    This review was conducted to provide information to support the establishment of clinical guidelines for the treatment of maxillary edentulism using implant-supported fixed dental prostheses. Initial efforts were directed toward a systematic review with a defined PICO question: "For maxillary edentulous patients with dental implants treated using a fixed prosthesis, what is the impact of prosthesis design on prosthesis survival and complications?" Following a title search of more than 3,000 titles identified by electronic search of PubMed, 180 articles were identified that addressed the clinical evaluation of maxillary dental implant prostheses. The broad methodologic heterogeneity and clinical variation among reports precluded this approach for a systematic review. The information was extracted using a standardized extraction table by two pairs of investigators, and the reported outcomes were then summarized according to reported outcomes for implant prostheses supported by four, six, or eight implants using unitary or segmented prostheses. This review indicated that high prosthetic survival is observed using all approaches. The advantages of using fewer implants and a unitary prosthesis are revealed in the surgical phases, and complications commonly involve the fracture or detachment of acrylic teeth and reduced access for proper oral hygiene and related biologic complications. Using six implants typically involved grafting of posterior regions with advantages of reduced cantilevers and redundancy of implant support. Reduced prosthesis survival in these cases was associated with poor implant distribution. Segmented prostheses supported by six or more implants offered greater prosthetic survival, perhaps due to posterior implant placement. Advantages of a segmented prosthesis included pragmatic issues of accommodating divergent implants, attaining passive fit, combining prosthetic materials, and relative simplicity of repair. The existing literature demonstrated

  14. Titanium versus zirconia implants supporting maxillary overdentures: three-dimensional finite element analysis.

    Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V

    2013-01-01

    The purpose of this study was to compare the stress and strain occurring in peri-implant bone and implants used to support maxillary overdentures. Three-dimensional finite element analysis (3D FEA) was used to compare one-piece zirconia and titanium implants. Two types of implants were simulated using a 3D FEA model: one-piece zirconia and titanium implants (diameter, 3.8 × 11.5 mm) with 2.25-mm diameter ball abutments. In each simulation four implants were placed bilaterally in the canine/premolar region of an edentulous maxillary model. Static loads were applied axially and 20 degrees buccolingually on the buccal slope of the lingual cusps of posterior teeth of the first quadrant. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated. Comparable stress and strain values were shown in the peri-implant bone for both types of implants. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. Under oblique loading, maximum von Mises stresses and equivalent strain were more evident at the neck of the most distal implant on the loaded side. Under axial load, the stress and strain were transferred to the peri-implant bone around the apex of the implant. Maximum tensile stresses that developed for either material were well below their fracture strength. The highest stresses were mainly located at the distobuccal region of the neck for the two implant materials under both loading conditions. From a biomechanical point of view, ceramic implants made from yttrium-stabilized tetragonal polycrystalline zirconia may be a potential alternative to conventional titanium implants for the support of overdentures. This is particularly relevant for a select group of patients with a proven allergy to titanium. Prospective clinical studies are still required to confirm these in vitro results. Different simulations presenting various cortical bone

  15. Trauma to an implant-supported crown that was saved by the fixation screw : A case report

    den Hartog, Laurens; Meijer, Henny J. A.; Stellingsma, Kees; Santing, Hendrik J.; Raghoebar, Gerry M.

    A traumatic impact to an implant-supported crown might damage the implant, restoration and peri-implant tissues. Ideally, only a small prosthetic retreatment is needed for restoration, as complicated prosthetic retreatments or surgical retreatments in particular, could be very inconvenient for the

  16. Implant-supported mandibular removable partial dentures: Functional, clinical and radiographical parameters in relation to implant position.

    Jensen, Charlotte; Speksnijder, Caroline M; Raghoebar, Gerry M; Kerdijk, Wouter; Meijer, Henny J A; Cune, Marco S

    2017-06-01

    Patients with a Kennedy class I situation often encounter problems with their removable partial denture (RPD). To assess the functional benefits of implant support to RPDs, the clinical performance of the implants and teeth and to determine the most favorable implant position: the premolar (PM) or molar (M) region. Thirty subjects received 2 PM and 2 M implants. A new RPD was made. Implant support was provided 3 months later. In a cross-over model, randomly, 2 implants (PM or M) supported the RPD during 3 months. Masticatory performance was assessed using the mixing ability index (MAI). Clinical and radiographic parameters were assessed. Non-parametric statistical analysis for related samples and post hoc comparisons were performed. Masticatory performance differed significantly between the stages of treatment (P < .001). MAI-scores improved with implant support although the implant position had no significant effect. No complications to the implants or RPD were observed and clinical and radiographical parameters for both implants and teeth were favorable. Higher scores for bleeding on probing were seen for molar implants. Implant support to a Kennedy class I RPD significantly improves masticatory function, regardless of implant position. No major clinical problems were observed. © 2017 Wiley Periodicals, Inc.

  17. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position

    Jensen, Charlotte; Raghoebar, Gerry M.; Kerdijk, Wouter; Meijer, Henny J. A.; Cune, Marco S.

    2016-01-01

    Objectives: To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Methods: Thirty subjects with a bilateral

  18. [A phd completed 10. Implant-supported removable partial -dentures in a Kennedy Class I-situation in the mandible].

    Jensen-Louwerse, C

    2017-06-01

    Implant-supported removable partial dentures in the mandible often cause problems, which means that patients wear their dentures seldom if at all. A solution is to place implants that the dentures can be snapped onto. There is, however, no consensus about the best position of the implants in the mandible yet. In addition, it is worthwhile to balance the cost of treatment with its effectiveness. In a randomised cross-over clinical trial involving 30 patients with a shortened dental arch, the implant-supported removable partial denture in the mandible was evaluated based on the experience of the patient, mean time of wearing, chewing ability and the clinical and radiographic parameters in relation to 2 different implant positions: 2 in the pre-molar region or 2 in the molar region. The cost-effectiveness of both treatments was also evaluated. From the patient's point of view, the implant-supported removable partial dentures are best supported by implants placed in the molar region. The research also revealed, however, that significantly more bleeding occurred around implants placed in the molar region and from a clinical perspective placement in the pre-molar region would have preference. The cost-effectiveness of the treatment with an implant-supported removable partial denture depends on the choice of outcome measurement and monetary threshold.

  19. Implant-supported mandibular removable partial dentures : Functional, clinical and radiographical parameters in relation to implant position

    Jensen, Charlotte; Speksnijder, Caroline M.; Raghoebar, Gerry M.; Kerdijk, Wouter; Meijer, Henny J A; Cune, Marco S.

    Background: Patients with a Kennedy class I situation often encounter problems with their removable partial denture (RPD). Purpose: To assess the functional benefits of implant support to RPDs, the clinical performance of the implants and teeth and to determine the most favorable implant position:

  20. Implant-supported overdentures, a prevention of bone loss in edentulous mandibles? A 5-year follow-up study

    von Wowern, N; Gotfredsen, K

    2001-01-01

    The purpose of this study were to analyse 1) the changes in the bone mineral content (BMC) in mandibles with implant-supported overdentures when compared with the physiologic age-related mandibular BMC loss, 2) whether the BMC changes were different in groups without or with a bar connecting...

  1. Long-term survival rate of implant-supported overdentures with various attachment systems: A 20-year retrospective study

    Hao-Sheng Chang

    2015-03-01

    Conclusion: The overall survival rate of dental implants with overdenture rehabilitation was 95.3% (91.3% in maxillae vs. 96.4% in mandibles within the past 20 years. With careful treatment planning, implant-supported overdenture is an interesting treatment alternative with better esthetic, retention, stability, and good hygienic maintenance for patients with severe ridge resorption.

  2. Replacement of a hopeless maxillary central incisor: a technique for the fabrication of an immediate implant-supported interim restoration.

    Graiff, Lorenzo; Vigolo, Paolo

    2012-04-01

    Placement of a dental implant and an interim restoration in the esthetic zone immediately following tooth extraction is now a common procedure. However, in such clinical situations, the fabrication of an appropriate interim restoration may be challenging. The aim of this article is to present a technique for modifying the extracted tooth so it can be used as an implant-supported interim restoration.

  3. A Generic Methodology for Superstructure Optimization of Different Processing Networks

    Bertran, Maria-Ona; Frauzem, Rebecca; Zhang, Lei

    2016-01-01

    In this paper, we propose a generic computer-aided methodology for synthesis of different processing networks using superstructure optimization. The methodology can handle different network optimization problems of various application fields. It integrates databases with a common data architecture......, a generic model to represent the processing steps, and appropriate optimization tools. A special software interface has been created to automate the steps in the methodology workflow, allow the transfer of data between tools and obtain the mathematical representation of the problem as required...

  4. Retention of implant-supported zirconium oxide ceramic restorations using different luting agents.

    Nejatidanesh, Farahnaz; Savabi, Omid; Shahtoosi, Mojtaba

    2013-08-01

    The aim of this study was to evaluate the retention value of implant-supported zirconium oxide ceramic copings using different luting agents. Twenty ITI solid abutments of 5.5 mm height and ITI implant analogs were mounted vertically into autopolymerizing acrylic resin blocks. Ninety zirconium oxide copings (Cercon, Degudent) with a loop on the occlusal portion were made. All samples were airborne particle abraded with 110 μm Al₂O₃ and luted using different types of luting agents: resin cements (Clearfil SA, Panavia F2.0, Fuji Plus), conventional cements (Fleck's, Poly F, Fuji I), and temporary cements (Temp Bond, GC free eugenol, TempSpan) with a load of 5 Kg. (N = 10) All copings were incubated at 37°C for 24 h and conditioned in artificial saliva for 1 week, and thermal cycled for 5000 cycles 5-55°C with a 30-s dwell time. The dislodging force of the copings along the long axis of the implant-abutment complex was recorded using universal testing machine with 5 mm/min crosshead speed. Data were subjected to Kruskal-Wallis (α = 0.05) and Mann-Whitney tests with Bonferroni step down correction (α = 0.001). There was significant difference between the mean rank retention values of different luting agents (P zirconium oxide restorations. © 2011 John Wiley & Sons A/S.

  5. Influence of laser-welding and electroerosion on passive fit of implant-supported prosthesis.

    Silva, Tatiana Bernardon; De Arruda Nobilo, Mauro Antonio; Pessanha Henriques, Guilherme Elias; Mesquita, Marcelo Ferraz; Guimaraes, Magali Beck

    2008-01-01

    This study investigated the influence of laser welding and electroerosion procedure on the passive fit of interim fixed implant-supported titanium frameworks. Twenty frameworks were made from a master model, with five parallel placed implants in the inter foramen region, and cast in commercially pure titanium. The frameworks were divided into 4 groups: 10 samples were tested before (G1) and after (G2) electroerosion application; and another 10 were sectioned into five pieces and laser welded before (G3) and after (G4) electroerosion application. The passive fit between the UCLA abutment of the framework and the implant was evaluated using an optical microscope Olympus STM (Olympus Optical Co., Tokyo, Japan) with 0.0005mm of accuracy. Statistical analyses showed significant differences between G1 and G2, G1 and G3, G1 and G4, G2 and G4. However, no statistical difference was observed when comparing G2 and G3. These results indicate that frameworks may show a more precise adaptation if they are sectioned and laser welded. In the same way, electroerosion improves the precision in the framework adaptation.

  6. The stereognostic ability of natural dentitions versus implant-supported fixed prostheses or overdentures.

    Jacobs, R; Bou Serhal, C; van Steenberghe, D

    1997-06-01

    A stereognostic ability test was performed in 60 patients. Forty patients were rehabilitated by means of osseointegrated implants. One group consisted of 20 patients with fixed prostheses on implants in both the upper and lower jaws. The other 20 patients had a maxillary denture while in the mandible an overdenture was retained by means of two implants connected by a bar. They were compared to a group of 20 subjects (controls) with a non-restored natural dentition. For the stereognostic ability test, subjects had to recognise ten different test pieces by manipulating them with two antagonistic incisor teeth, avoiding any contact with other oral structures. Both response time and percentage accuracy of recognition were evaluated. The present findings indicated that subjects with an overdenture on implants did not score significantly different from those with an implant-supported fixed prosthesis. In contrast, subjects with teeth had a significantly better stereognostic ability. The percentage of correct responses was 52% for overdentures, 56% for fixed prostheses on implants and 75% for natural dentitions. From these results, it could be concluded that the stereognostic ability is impaired in subjects rehabilitated with osseointegrated implants by about one-third to one-quarter compared to subjects with natural teeth.

  7. All on Four® fixed implant support rehabilitation: a masticatory function study.

    De Rossi, Moara; Santos, Carla Moreto; Migliorança, Reginaldo; Regalo, Simone Cecílio Hallak

    2014-08-01

    Fixed implant-supported prostheses according to All-on-Four® (Nobel Biocare, Goteborg, Sweden) principles have become an accepted treatment modality in totally edentulous patients, whereas the functional effect of this therapy is limited. The purpose of this study was to evaluate the muscular function of patients totally rehabilitated with All-on-Four. This study evaluated 63 patients. Twenty-one patients were successfully rehabilitated with maxillary and mandibular All-on-Four (no dropout implants, satisfactory aesthetic and function demands prosthesis), 21 patients were dentate, and 21 were rehabilitated with double complete dentures. Electromyography was carried out during clenching, nonhabitual and habitual chewing, and rest. All values were standardized as percentage of a maximum voluntary contraction. Data were analyzed by ANOVA to compare groups and paired t-test was used for comparison between sides within each group. All groups presented symmetric muscular activity. The All-on-Four and dentate groups had a similar muscles surface electromyography (sEMG) contraction pattern, that is, a higher sEMG activity of masseter than temporalis muscles, differing (p ≤ .05) from those of denture group. Not one statistical difference was found between All-on-Four and dentate groups. The muscular function similarity of All-on-Four and dentate patients shows that this treatment concept may be considered as a good option for oral rehabilitation in edentulous patients. © 2013 Wiley Periodicals, Inc.

  8. Technique for systematic bone reduction for fixed implant-supported prosthesis in the edentulous maxilla.

    Bidra, Avinash S

    2015-06-01

    Bone reduction for maxillary fixed implant-supported prosthodontic treatment is often necessary to either gain prosthetic space or to conceal the prosthesis-tissue junction in patients with excessive gingival display (gummy smile). Inadequate bone reduction is often a cause of prosthetic failure due to material fractures, poor esthetics, or inability to perform oral hygiene procedures due to unfavorable ridge lap prosthetic contours. Various instruments and techniques are available for bone reduction. It would be helpful to have an accurate and efficient method for bone reduction at the time of surgery and subsequently create a smooth bony platform. This article presents a straightforward technique for systematic bone reduction by transferring the patient's maximum smile line, recorded clinically, to a clear radiographic smile guide for treatment planning using cone beam computed tomography (CBCT). The patient's smile line and the amount of required bone reduction are transferred clinically by marking bone with a sterile stationery graphite wood pencil at the time of surgery. This technique can help clinicians to accurately achieve the desired bone reduction during surgery, and provide confidence that the diagnostic and treatment planning goals have been achieved. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. The effect of varying implant position in immediately loaded implant-supported mandibular overdentures.

    Shaarawy, Mohammed A; Aboelross, Ehab M

    2013-06-01

    This study was carried out to evaluate the effect of varying implant position in immediately loaded implant-supported mandibular overdentures on peri-implant bone density, muscle activity, and patient satisfaction. Fourteen completely edentulous patients were selected for the study. After complete denture construction, patients were divided into 2 equal groups. Four dental implants were installed bilaterally in the interforaminal region in the first group, while in the second group, 4 dental implants were inserted bilaterally: 2 in the interforaminal region and 2 in the first molar area. Immediately after suturing, telescopic abutments were screwed to the implants, and the retaining caps were picked up into the fitting surface of the lower denture, which was delivered to the patient. Patients were recalled for radiographic bone density evaluation just after denture delivery and then at 3, 6, and 12 months thereafter. Muscle activities of masseter and temporalis muscles as well as patient satisfaction were also evaluated. The results of the study showed a high success rate approximating 98.2% of the immediately loaded implants. The electromyographic (EMG) records of both muscles in group 1 were significantly higher during chewing hard food after 3 months compared with group 2 (P overdentures through posterior placement beyond the interforaminal area results in a favorable response in terms of increased peri-implant bone density as well as decreased EMG activity of masseter and temporalis muscles.

  10. Retention system for implant-supported dentures used by brazilian dentists who work in implant dentistry

    Saturnino Aparecido Ramalho

    2010-04-01

    Full Text Available Objective: To provide the dentists with support in the choice of the cement or screw type of retention for implant-supported dentures, according to the patient’s problem. Methods: An opinion questionnaire was applied to a sample of 468 participants, all dentists working in the field of Implant Dentistry, of whom 272 (58.1% participated in the 4th International Congress of Osseointegration of APCD, held in São Paulo (SP from 6 to 9 May 2004, 119 (25.4% participated in the 2nd International Congress of Implant Dentistry of Minas Gerais, between 10 and 12 June 2004 and 77 (16.5% were professors and specialization and master students from São Leopoldo Mandic. Results: The results showed that 254 participants opted for the screw-retained system while 214 opted for the cement-retained system. Conclusion: There was a preference for the use of the screw-retained system, and that both cemented and screw-retained systems have advantages and disadvantages, so that the dentist is left to decide and evaluate them in order to indicate and use them with confidence in different clinical cases.

  11. A new classification of peri-implant bone morphology: a radiographic study of patients with lower implant-supported mandibular overdentures

    Zhang, L.; Geraets, W.; Zhou, Y.; Wu, W.; Wismeijer, D.

    2014-01-01

    Objective This study aimed to classify peri-implant bone defects (PIBDs) on the basis of their radiographic appearance in a cohort of patients with lower implant-supported overdentures. Materials and methods Eighty-three patients with lower implant-supported overdentures were recruited to

  12. 40 CFR 745.228 - Accreditation of training programs: public and commercial buildings, bridges and superstructures...

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Accreditation of training programs: public and commercial buildings, bridges and superstructures. [Reserved] 745.228 Section 745.228... Accreditation of training programs: public and commercial buildings, bridges and superstructures. [Reserved] ...

  13. 46 CFR 108.133 - Hull superstructure, structural bulkheads, decks, and deckhouses.

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hull superstructure, structural bulkheads, decks, and deckhouses. 108.133 Section 108.133 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A... Protection § 108.133 Hull superstructure, structural bulkheads, decks, and deckhouses. Each hull...

  14. Role of Steric Hindrance in the Crystal Packing of Z′ = 4 Superstructure of Trimethyltin Hydroxide

    Dey, S.; Schö nleber, A.; Mondal, S.; Ali, S. I.; van Smaalen, S.

    2018-01-01

    The roomerature crystal structure of trimethyltin hydroxide, (CH)SnOH, has been described by Anderson et al. [Cryst. Growth Des. 2011, 11, 820-826] as a 2a × 2b × 8c, 32-fold superstructure. We report a a × b × 8c, eight-fold superstructure

  15. Voids and superstructures: correlations and induced large-scale velocity flows

    Lares, Marcelo; Luparello, Heliana E.; Maldonado, Victoria; Ruiz, Andrés N.; Paz, Dante J.; Ceccarelli, Laura; Garcia Lambas, Diego

    2017-09-01

    The expanding complex pattern of filaments, walls and voids build the evolving cosmic web with material flowing from underdense on to high density regions. Here, we explore the dynamical behaviour of voids and galaxies in void shells relative to neighbouring overdense superstructures, using the Millenium simulation and the main galaxy catalogue in Sloan Digital Sky Survey data. We define a correlation measure to estimate the tendency of voids to be located at a given distance from a superstructure. We find voids-in-clouds (S-types) preferentially located closer to superstructures than voids-in-voids (R-types) although we obtain that voids within ˜40 h-1 Mpc of superstructures are infalling in a similar fashion independently of void type. Galaxies residing in void shells show infall towards the closest superstructure, along with the void global motion, with a differential velocity component depending on their relative position in the shell with respect to the direction to the superstructure. This effect is produced by void expansion and therefore is stronger for R-types. We also find that galaxies in void shells facing the superstructure flow towards the overdensities faster than galaxies elsewhere at the same relative distance to the superstructure. The results obtained for the simulation are also reproduced for the Sky Survey Data Release data with a linearized velocity field implementation.

  16. Turbulent thermal superstructures in Rayleigh-Bénard convection

    Stevens, Richard J. A. M.; Blass, Alexander; Zhu, Xiaojue; Verzicco, Roberto; Lohse, Detlef

    2018-04-01

    We report the observation of superstructures, i.e., very large-scale and long living coherent structures in highly turbulent Rayleigh-Bénard convection up to Rayleigh Ra=109 . We perform direct numerical simulations in horizontally periodic domains with aspect ratios up to Γ =128 . In the considered Ra number regime the thermal superstructures have a horizontal extend of six to seven times the height of the domain and their size is independent of Ra. Many laboratory experiments and numerical simulations have focused on small aspect ratio cells in order to achieve the highest possible Ra. However, here we show that for very high Ra integral quantities such as the Nusselt number and volume averaged Reynolds number only converge to the large aspect ratio limit around Γ ≈4 , while horizontally averaged statistics such as standard deviation and kurtosis converge around Γ ≈8 , the integral scale converges around Γ ≈32 , and the peak position of the temperature variance and turbulent kinetic energy spectra only converge around Γ ≈64 .

  17. Nonlinear analysis of collapse mechanism in superstructure vehicle

    Nor, M. K. Mohd; Ho, C. S.; Ma'at, N.

    2017-04-01

    The EU directive 2001/85/EC is an official European text which describes the specifications for "single deck class II and III vehicles" required to be approved by the regulation UN/ECE no.66 (R66). To prevent the catastrophic consequences by occupant during an accident, the Malaysian government has reinforced the same regulation upon superstructure construction. This paper discusses collapse mechanism analysis of a superstructure vehicle using a Crash D nonlinear analysis computer program based on this regulation. The analysis starts by hand calculation to define the required energy absorption by the chosen structure. Simple calculations were then performed to define the weakest collapse mechanism after undesirable collapse modes are eliminated. There are few factors highlighted in this work to pass the regulation. Using the selected cross section, Crash D simulation showed a good result. Generally, the deformation is linearly correlates to the energy absorption for the structure with low stiffness. Failure of critical members such as vertical lower side wall must be avoided to sustain safety of the passenger compartment and prevent from severe and fatal injuries to the trapped occupant.

  18. Control superstructure of rigid polyelectrolytes in oppositely charged hydrogels via programmed internal stress

    Takahashi, Riku; Wu, Zi Liang; Arifuzzaman, Md; Nonoyama, Takayuki; Nakajima, Tasuku; Kurokawa, Takayuki; Gong, Jian Ping

    2014-08-01

    Biomacromolecules usually form complex superstructures in natural biotissues, such as different alignments of collagen fibres in articular cartilages, for multifunctionalities. Inspired by nature, there are efforts towards developing multiscale ordered structures in hydrogels (recognized as one of the best candidates of soft biotissues). However, creating complex superstructures in gels are hardly realized because of the absence of effective approaches to control the localized molecular orientation. Here we introduce a method to create various superstructures of rigid polyanions in polycationic hydrogels. The control of localized orientation of rigid molecules, which are sensitive to the internal stress field of the gel, is achieved by tuning the swelling mismatch between masked and unmasked regions of the photolithographic patterned gel. Furthermore, we develop a double network structure to toughen the hydrogels with programmed superstructures, which deform reversibly under large strain. This work presents a promising pathway to develop superstructures in hydrogels and should shed light on designing biomimetic materials with intricate molecular alignments.

  19. Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments.

    Kono, Kentaro; Kurihara, Daisuke; Suzuki, Yasunori; Ohkubo, Chikahiro

    2014-04-01

    This in vitro study investigated the pressure distribution of the implant-supported removable partial dentures (RPDs) with the stress-breaking attachments under the occlusal force. The experimental model of bilateral missing premolars and molars was modified from a commercial simulation model. Five pressure sensors were embedded near the bilateral first molars, first premolars, and medio-lingual alveolar crest. Two implants were placed near the second molars, and they were connected to the denture base using the following conditions: complete separation between the denture base and implant with cover screws (CRPD), flexible connection with a stress-breaking ball (SBB) attachment, and rigid connection without stress breaking with healing caps (HC). The pressure at five different areas of the soft tissue and the displacement of the RPDs were simultaneously measured, loading up to 50 N. The coefficient of variation (CV) for each connection was calculated from all data of the pressure at five areas to evaluate the pressure distribution. The pressure on medio-lingual alveolar crest and molars of the HC was less than SBB and CRPD. In contrast, the pressure on premolars of SBB was greater than for the HC and CRPD. The CV of SBB was less than that of HC and CRPD. Denture displacement of HC and SBB was less than for CRPD. Within the in vitro limitations, precise denture settlements and pressure distribution under the denture base could be controlled using an SBB attachment. An SBB attachment might be able to protect the implant from harmful force. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  20. Implant-supported removable partial dentures in the mandible: A 3-16 year retrospective study.

    Jensen, Charlotte; Meijer, Henny J A; Raghoebar, Gerry M; Kerdijk, Wouter; Cune, Marco S

    2017-04-01

    The purpose of this retrospective study was to assess performance, together with biological and technical complications, of implant-supported removable partial dentures (ISRPD) in mandibular Kennedy class I situations with implants placed in the anterior or posterior position. 23 subjects with two endosseous implants to support a bilateral-free-ending mandibular removable denture were examined. Eight subjects had implants in the premolar (anterior) region and 15 subjects implants in the molar (posterior) region. Biological and technical complications were recorded from the patients' medical record. Patients filled out a validated questionnaire regarding their appreciation of oral health related quality of life (OHIP-NL49) and a VAS score on overall satisfaction. Over a mean follow-up period of 8 years (median 8 years, range 3-16 years) the cumulative implant survival rate was 91.7% (SE 0.05). Mean peri-implant bone loss was 0.9mm (SD 1.0mm). Scores for bleeding on probing, plaque and mucosal health were generally low, but significantly worse for posteriorly placed implants. Significantly more biological complications occurred in the posterior group (X 2 (1)=3.9; p=0.048). In 65% of the cases no technical complications were registered. Mean overall OHIP score was 16.1 (SD 18.4) and patients were highly satisfied (VAS: 8.4; SD 2.1). Within the limitations of this retrospective study, in case of a Kennedy class I situation in the mandible, an ISRPD is a viable treatment option with a high implant survival rate and satisfied patients after a maximum of 16 years. Technical and biological complications should be anticipated. Anteriorly placed implants performed slightly better. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  1. The effect of implant-supported removable partial dentures on oral health quality of life.

    Gates, W Day; Cooper, Lyndon F; Sanders, Anne E; Reside, Glenn J; De Kok, Ingeborg J

    2014-02-01

    Removable partial dentures (RPDs) represent standard treatment for partial edentulism despite major shortcomings. To alleviate these shortcomings, endosseous implants provide support and stability as well as contribute to maintenance of alveolar bone. This prospective, within subject, time series study evaluated patient-based outcomes of RPDs compared to implant-supported removable partial dentures (ISRPDs). The study hypothesis was that the ISRPD would substantially improve oral health quality of life for patients. Seventeen patients requesting new mandibular Kennedy I or II RPDs received one 6-mm dental implant in one or both of the posterior edentulous areas. After healing, conventional RPDs were fabricated and delivered. Twelve weeks later, second-stage surgery was performed, and ball abutments with Clix attachments were inserted, thereby converting the prostheses to ISRPDs. Oral health quality of life was evaluated using the 49-item Oral Health Impact Profile (OHIP-49) questionnaire. The OHIP-49 was administered prior to treatment (baseline), at 6 and 12 weeks following RPD delivery and at 6 and 12 weeks following ISRPD conversion. Radiographic evaluation was performed at 6 and 12 weeks following ISRPD conversion. In statistical analysis, a fixed-slope random intercept variance components model took account of the multiple observations per person over time. In 17 subjects, 29 of 30 implants survived. The failed implant was replaced without complications. Abutment complications were limited to one abutment loosening and one attachment replacement. Minor prosthodontic complications were recorded. The OHIP-49 score reduced by 11.8 points, on average, at 12 weeks following ISRPD conversion (P = 0.011). Patients reported improved oral health following conversion to an ISRPD from RPD. The ISRPD involving short implants is one treatment option that should be considered when treatment planning Kennedy Class I and II patients. © 2012 John Wiley & Sons A/S.

  2. In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures.

    Koke, U; Wolf, A; Lenz, P; Gilde, H

    2004-05-01

    Mismatch occurring during the fabrication of implant-supported dentures may induce stress to the peri-implant bone. The purpose of this study was to investigate the influence of two different alloys and the fabrication method on the marginal accuracy of cast partial dentures. Two laboratory implants were bonded into an aluminium block so that the distance between their longitudinal axes was 21 mm. Frameworks designed for screw-retained partial dentures were cast either with pure titanium (rematitan) or with a CoCr-alloy (remanium CD). Two groups of 10 frameworks were cast in a single piece. The first group was made of pure titanium, and the second group of a CoCr-alloy (remanium CD). A third group of 10 was cast in two pieces and then laser-welded onto a soldering model. This latter group was also made of the CoCr-alloy. All the frameworks were screwed to the original model with defined torque. Using light microscopy, marginal accuracy was determined by measuring vertical gaps at eight defined points around each implant. Titanium frameworks cast in a single piece demonstrated mean vertical gaps of 40 microm (s.d. = 11 microm) compared with 72 microm (s.d. = 40 microm) for CoCr-frameworks. These differences were not significant (U-test, P = 0.124) because of a considerable variation of the values for CoCr-frameworks (minimum: 8 microm and maximum: 216 microm). However, frameworks cast in two pieces and mated with a laser showed significantly better accuracy in comparison with the other experimental groups (mean: 17 microm +/- 6; P laser welding. Manufacturing the framework pieces separately and then welding them together provides the best marginal fit.

  3. Functional adaptation of the masticatory system to implant-supported mandibular overdentures.

    Giannakopoulos, Nikolaos Nikitas; Corteville, Frédéric; Kappel, Stefanie; Rammelsberg, Peter; Schindler, Hans Jürgen; Eberhard, Lydia

    2017-05-01

    The purpose of this study was to investigate the adaptation behavior of the stomatognathic system after immediate loading (24 to 72 h after surgery) of two implants supporting mandibular overdentures, assessed on insertion and three months later. The study hypothesis was that insertion of the overdentures would significantly change masticatory performance and muscle activity at both times. Thirty subjects (nine female, mean age 69.64 ± 11.81 years; 21 male, mean age 68.67 ± 7.41 years) who participated in a randomized clinical trial were included in the study. Each patient was examined three times: (i) at baseline, after already having worn new dentures for three months (T1); (ii) immediately after insertion of the overdentures on the implants (T2); and (iii) after an adaptation period of three months (T3). Examination comprised assessment of masticatory performance with artificial test food (Optocal), and simultaneous bilateral surface EMG recording of the masseter and anterior temporalis muscles. Particle-size distribution (representative value X 50 ), maximum muscle contraction (MVC), and total muscle work (TMW; area under the curve) were compared by use of repeated-measures analysis of variance (ANOVA). At T3, all measured variables (i.e., masticatory performance and muscle activity) were significantly different from those at T1. At T2, no significant changes were observed. The study hypothesis had to be rejected for T2 but accepted for T3. Functional rehabilitation (in terms of masticatory performance and masticatory muscle activity) does not occur immediately after immediate loading of two implants with mandibular overdentures, but requires a significant time for functional improvement. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Teaching mandibular implant-Supported overdentures in dental schools in North America - a survey.

    Ben-Gal, G; Ziv, Y; Weiss, E I; Zabrovsky, A

    2017-05-01

    Mandibular two-implant overdentures are considered the minimum standard of care for edentulous patients and provide an excellent performance, as well as satisfaction to the patients. Dental schools are required to promote the teaching of current treatment options in order to enable students to master state-of-the-art procedures. The purpose of this study was to examine how the theoretical and practical aspects of mandibular two-implant overdentures are taught in dental schools in North America. Data were collected via an online questionnaire that included questions regarding the theoretical and clinical courses, surgical procedure and imaging method. Of 75 schools, 36 responded to the survey. Almost all the schools teach the subject theoretically, but it is not mandatory for students to perform in most of the schools. Only a minority (23%) of the mandibular dentures made by students are implant-supported. Almost all of the schools (94%) use two implants to support overdentures, and Locator abutment is used almost exclusively. The prevalent imaging for the surgical procedure is CT scans, although 30% of the schools use panoramic radiograph. None of the schools loads the implants immediately after surgery. Some clear trends are apparent in the current survey: the use of two implants, no use of bar connectors and delayed loading of the implants. It is likely that graduates will not have sufficient clinical skills and will need continuing education to be familiar with the required procedures, both surgical and prosthetic. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. A feasible, aesthetic quality evaluation of implant-supported single crowns: an analysis of validity and reliability

    Hosseini, Mandana; Gotfredsen, Klaus

    2012-01-01

    OBJECTIVES: To test the reliability and validity of six aesthetic parameters and to compare the professional- and patient-reported aesthetic outcomes. MATERIAL AND METHODS: Thirty-four patients with 66 implant-supported premolar crowns were included. Two prosthodontists and 11 dental students......,24) were found between patient and professional evaluations. CONCLUSIONS: The feasibility, reliability and validity of the CIS make the parameters useful for quality control of implant-supported restorations. The professional- and patient-reported aesthetic outcomes had no significant correlation....... and the internal consistency were analysed by Cohen's ¿ and Cronbach's a, respectively. The validity of CIS parameters was tested against the corresponding Visual Analogue Scales (VAS) scores. The Spearman correlation coefficients were used. Six aesthetic Oral Health Impact Profile (OHIP) questions were correlated...

  6. Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model

    Ipsha Singh; K Chandrasekharan Nair; Jayakar Shetty

    2017-01-01

    Aim: The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. Materials and Methods: A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. Un...

  7. A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.

    Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti

    2014-02-01

    Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.

  8. The behavior of implant-supported dentures and abutments using the cemented cylinder technique with different resinous cements

    Ivete Aparecida de Mathias Sartori

    2008-01-01

    Full Text Available Objective: Evaluate the behavior of implant-supported dentures and their components, made by cemented cylinder technique, using threetypes of resin cements. Methods: Fifty three patients, of whom 26 were women and 27 men, aged between 25 and 82 years. Results: With partial (54.43% and total (45.57% implant-supported dentures, of the Cone Morse, external and internal hexagon types (Neodent®, Curitiba, Brazil, totaling 237 fixations, were analyzed. The resin cements used were Panavia® (21.94%, EnForce® (58.23% and Rely X® (19.83% and the components were used in accordance with the Laboratory Immediate Loading - Neodent® sequence. The period of time of denture use ranged between 1 and 5 years. The results reported that 5(2.1% cylinders were loosened from metal structure (both belonging to Rely X group, 2(0.48% implants were lost after the first year of use, 16(6.75% denture retention screws wereloosened and 31(13.08% abutment screws were unloosened.Conclusion: The reasons for these failures probably are: metal structure internal retention failure, occlusal pattern, cementation technique and loading conditions. The cemented cylinder technique was effective when used in partial and total implant-supported rehabilitations, keeping prosthetic components stable, despite the resin cement utilized. However, further clinical studies must be conducted.

  9. Abnormal Congenital Location of Stapes’ Superstructure: Clinical and Embryological Implications

    Vânia Henriques

    2016-01-01

    Full Text Available Congenital middle ear malformations are rare. Most part of them are usually associated with other malformations, such as aural atresia, microtia, and dysmorphic craniofacial features. A clinical case of a 24-year-old male with a right-sided conductive hearing loss since his childhood, without craniofacial malformation, is presented. He was proposed for exploratory tympanotomy under the suspicious diagnosis of otosclerosis. The surgery revealed an abnormal location of stapes’ superstructure, which was attached to the promontory and had an isolated and mobile osseous footplate in the oval window. A stapes prosthesis was inserted and resulted in closure of the air-bone gap by 25 dB. A review of the literature was also performed using MEDLINE. Two theories diverge on the embryologic origin of the stapes. Our findings seem to be in favour of the theory that defines two different embryologic origins to the stapes.

  10. Investigation of superstructure damping identification for the HDR containment building

    Hsieh, B.J.; Kot, C.A.; Srinivasan, M.G.

    1985-01-01

    A method for the estimation of first mode structural damping, developed by other investigators, was applied to shaker test data of the HDR containment building. Due to inadequate precision in the experimental phase measurements no valid results could be obtained. Based on modal analysis it was also noted that for systems such as the HDR building, contributions of higher modes are not negligible as was assumed in the original approach. Therefore, the procedure for the determination of superstructure damping using experimental data was extended to include the effects of higher modes. The extended method does not lead to any higher order nonlinear equations than the first mode approximation and was found to be as simple to apply as the original approach

  11. Multi-objective superstructure-free synthesis and optimization of thermal power plants

    Wang, Ligang; Lampe, Matthias; Voll, Philip; Yang, Yongping; Bardow, André

    2016-01-01

    The merits of superstructure-free synthesis are demonstrated for bi-objective design of thermal power plants. The design of thermal power plants is complex and thus best solved by optimization. Common optimization methods require specification of a superstructure which becomes a tedious and error-prone task for complex systems. Superstructure specification is avoided by the presented superstructure-free approach, which is shown to successfully solve the design task yielding a high-quality Pareto front of promising structural alternatives. The economic objective function avoids introducing infinite numbers of units (e.g., turbine, reheater and feedwater preheater) as favored by pure thermodynamic optimization. The number of feasible solutions found per number of mutation tries is still high even after many generations but declines after introducing highly-nonlinear cost functions leading to challenging MINLP problems. The identified Pareto-optimal solutions tend to employ more units than found in modern power plants indicating the need for cost functions to reflect current industrial practice. In summary, the multi-objective superstructure-free synthesis framework is a robust approach for very complex problems in the synthesis of thermal power plants. - Highlights: • A generalized multi-objective superstructure-free synthesis framework for thermal power plants is presented. • The superstructure-free synthesis framework is comprehensively evaluated by complex bi-objective synthesis problems. • The proposed framework is effective to explore the structural design space even for complex problems.

  12. Effect of Diamondlike Carbon Coating on Reliability of Implant-Supported Crowns.

    Hirata, Ronaldo; Machado, Lucas Silveira; Bonfante, Estevam A; Yamaguchi, Satoshi; Imazato, Satoshi; Coelho, Paulo G

    2015-01-01

    To evaluate the effect of diamondlike carbon (DLC) coating on abutments and/or abutment screws on the reliability, characteristic strength, and Weibull modulus of implant-supported single crowns. Seventy-two external hexagon implants (Emfills Implant 4 mm diameter, 10 mm length, Emfills) were divided into four groups (n = 18 each), according to the presence or not of a DLC coating in the abutment and/or abutment screw, as follows: abutment without coating, screw without coating (AwcSwc); abutment without coating with coated screw (AwcSC); abutment coated with noncoated screw (ACSwc), and coated abutment with coated screw (ACSC). Abutments and screws were evaluated with scanning electron microscopy. The specimens were subjected to step-stress accelerated life testing in water. Use-level probability Weibull curves and reliability for a mission of 100,000 cycles at 150 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. For a mission of 100,000 cycles at 150 N, reliability was 0.45 (0.20 to 0.67), 0.12 (0.00 to 0.47), 0.56 (0.17 to 0.82), and 0.44 (0.07 to 0.77) for AwcSwc, AwcSC, ACSwc, and ACSC, respectively. The probability Weibull calculation showed a Weibull modulus (m) of m = 5.50, m = 11.64, m = 16.96, and m = 15.08 and the characteristic strengths (η, which indicates the load at which 63.2% of the specimens of each group fail) of η = 202.67 N, ŋ = 206.64 N, ŋ = 192.54 N, and ŋ = 203.59 N for AwcSwc, AwcSC, ACSwc, and ACSC, respectively. Abutment screw fracture was the chief failure outcome in all groups. Characteristic strength values were not different among groups; neither was reliability. However, an increase in Weibull modulus (indicating low variability of the results) was observed with DLC coating of abutment or screw or both.

  13. A simplified method to reduce prosthetic misfit for a screw-retained, implant-supported complete denture using a luting technique and laser welding.

    Longoni, Salvatore; Sartori, Matteo; Davide, Roberto

    2004-06-01

    An important aim of implant-supported prostheses is to achieve a passive fit of the framework with the abutments to limit the amount of stress transfer to the bone-implant interface. An efficient and standardized technique is proposed. A definitive screw-retained, implant-supported complete denture was fabricated for an immediately loaded provisional screw-retained implant-supported complete denture. Precise fit was achieved by the use of industrial titanium components and the passivity, by an intraoral luting sequence and laser welding.

  14. Linking experiment and theory for three-dimensional networked binary metal nanoparticle–triblock terpolymer superstructures

    Li, Zihui; Hur, Kahyun; Sai, Hiroaki; Higuchi, Takeshi; Takahara, Atsushi; Jinnai, Hiroshi; Gruner, Sol M.; Wiesner, Ulrich

    2014-01-01

    the intimate coupling of synthesis, in-depth electron tomographic characterization and theory enables exquisite control of superstructure in highly ordered porous three-dimensional continuous networks from single and binary mixtures of metal nanoparticles

  15. Large-scale laboratory observations of wave forces on a highway bridge superstructure.

    2011-10-01

    The experimental setup and data are presented for a laboratory experiment conducted to examine realistic wave forcing on a highway bridge : superstructure. The experiments measure wave conditions along with the resulting forces, pressures, and struct...

  16. Evaluation of marginal fit of single implant-supported metal-ceramic crowns prepared by using presintered metal blocks.

    Pasali, Baris; Sarac, Duygu; Kaleli, Necati; Sarac, Yakup Sinasi

    2018-02-01

    Recently, presintered metal blocks for nonprecious and precious metal implant-supported restorations have gained popularity in computer-aided design and computer-aided manufacturing (CAD-CAM) systems. However, few studies have evaluated the marginal discrepancy of implant-supported restorations made with these new alloy systems. The purpose of this in vitro study was to compare the milling-sintering method with the lost-wax and milling methods in terms of the marginal fit of implant-supported metal-ceramic restorations. Thirty implant abutments screwed to implant analogs were embedded into acrylic resin to investigate marginal fit and then divided according to fabrication methods into the following 3 groups (n=10): lost-wax (LW; control group), milling (M), and milling-sintering (MS). Porcelain material was applied to all specimens after completion of the fabrication process. Subsequently, all specimens were cemented to implant abutments for the measurement of marginal discrepancies. Twelve marginal discrepancy measurements were recorded on each implant abutment by using a stereomicroscope. The arithmetic mean of these 12 measurements was considered the mean marginal discrepancy value of each abutment. Data were statistically analyzed by using 1-way ANOVA and Tukey honest significant difference tests (α=.05). The lowest mean marginal discrepancy values (81 ±2 μm) were observed in the M group, which was significantly different (Pmarginal discrepancy values (99 ±2 μm) were observed in the MS group. The results revealed that restorations prepared by the milling-sintering method provided clinically acceptable results (marginal fit. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Oral rehabilitation with implant supported overdentures in patients with non-reconstructed segmental mandibulectomy: A report of two cases

    Rok Zupančič

    2013-11-01

    Full Text Available Background: Segmental mandibulectomy is most often performed as part of resection of advanced squamous cell carcinoma, which involves the mandible by extension from intraoral tissues and is usually followed by reconstruction of the mandible. However, not all mandibular defects can be surgically reconstructed, due to local or systemic factors. Oral rehabilitation with conventional removable dentures is often insufficient. In order to provide predictable support and denture retention, especially in the non-reconstructed cases of segmental mandibulectomy, dental implants are indicated.Case report: The authors describe oral rehabilitation with implant-supported overdenture in two non-reconstructed patients with similar mandibular defect, but different etiology, as well as different denture design and different outcome in terms of success and patient satisfaction. In the first case, the defect was caused by surgical treatment of cancer, which was followed by radiotherapy and prosthodontic treatment with an implant-supported mandibular overdenture anchored with a bar. In another case, the damage was due to a suicide attempt. This was initially followed by the surgical treatment of the injury. Afterwards, the prosthodontic treatment with an implant-supported and conical–crown-anchored mandibular overdenture was performed.Conclusions: The success of the prosthodontic oral rehabilitation of patients with segmental mandibulectomy depends on many factors. The size of the defect and the condition of the remaining hard and soft tissues, which are affected by radiotherapy, are crucial. The etiology of the defect, the opposing jaw status, maxillomandibular relationships, the consistency of mandibular movement and the denture design play an important role as well.

  18. Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials

    Vahideh Nazari

    2017-01-01

    Full Text Available Objectives: Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS. The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs with excessive crown height, fabricated from three different materials.Materials and Methods: Two implants with corresponding abutments were mounted in a metal model that simulated mandibular second premolar and second molar. Thirty 3-unit frameworks with supportive anatomical design were fabricated using zirconia, nickel-chromium alloy (Ni-Cr, and polyetheretherketone (PEEK (n=10. After veneering, the CHS was equal to 15mm. Then; samples were axially loaded on the center of pontics until fracture in a universal testing machine at a crosshead speed of 0.5 mm/minute. The failure load data were analyzed by one-way ANOVA and Games-Howell tests at significance level of 0.05.Results: The mean failure loads for zirconia, Ni-Cr and PEEK restorations were 2086±362N, 5591±1200N and 1430±262N, respectively. There were significant differences in the mean failure loads of the three groups (P<0.001. The fracture modes in zirconia, metal ceramic and PEEK restorations were cohesive, mixed and adhesive type, respectively.Conclusions: According to the findings of this study, all implant supported three-unit FPDs fabricated of zirconia, metal ceramic and PEEK materials are capable to withstand bite force (even para-functions in the molar region with excessive CHS.Keywords: Dental Implants; Polyetheretherketone; Zirconium oxide; Dental Restoration Failure; Dental Porcelain

  19. Clinical research in implant dentistry: evaluation of implant-supported restorations, aesthetic and patient-reported outcomes.

    Lang, Niklaus P; Zitzmann, Nicola U

    2012-02-01

    The articles discussed in working group 3 dealt with specific aspects of clinical research. In this context, the literature reporting on survival and complication rates of implant-supported or implant-tooth supported restorations in longitudinal studies of at least 5 years were discussed. The second aspect dealt with the evaluation of aesthetic outcomes in clinical studies and the related index systems available. Finally, the third aspect discussed dealt with patient-reported outcome measures (PROMs). A detailed appraisal of the available methodology was presented. © 2012 John Wiley & Sons A/S.

  20. Implant-supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5-year study

    Gotfredsen, K; Holm, B

    2001-01-01

    PURPOSE: The aim of the present study was to evaluate the periimplant conditions and the maintenance requirements for implant-supported overdentures in the mandible retained with ball or bar attachments during a 5-year period. MATERIALS AND METHODS: Twenty-six completely edentulous patients had two...... differences were registered. The mean frequency of complications/repairs per patient per year was 1.0 in the bar group and 0.6 in the ball group during the 5-year observation period. CONCLUSION: Two implants with ball or bar attachment supported an overdenture in the mandible for 5 years with a 100% survival...

  1. Bilateral Congenital Absence of the Stapes Superstructure in Two Siblings

    Jose Ignacio Undabeitia

    2014-01-01

    Full Text Available Middle ear ossicle malformations are an uncommon event. Among them, the congenital absence of the stapes is a very rare condition that is seldom described in the literature. We report the cases of two women, aged 19 and 22 , who presented with a long history of conductive deafness. An exploratory tympanotomy was performed and the absence of the stapes superstructure and an abnormal position of the facial nerve could be observed. A bone anchored hearing aid (BAHA was implanted in both patients with good results. It is believed that stapes agenesis is related to an abnormal development of the facial nerve, which by the 5th to 6th week of gestation would interpose between the otic capsule and the stapes blastema, preventing these structures from contacting. A long history of nonprogressive hearing loss from birth or early childhood is the key to reach a diagnosis. Several treatment options have been described. The authors opted for a hearing aid due to the high risk of facial nerve lesion, with good functional results.

  2. Effect of implant support on mandibular distal extension removable partial dentures: relationship between denture supporting area and stress distribution.

    Sato, Maki; Suzuki, Yasunori; Kurihara, Daisuke; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2013-04-01

    This study explored the relationship between implant support and the denture-supporting area by comparing the stability of an implant-supported distal extension removable partial denture and a conventional distal extension removable partial denture. A model simulating a mandibular bilateral distal extension missing (#34-37 and #44-47) was fabricated using silicone impression material as soft tissue (2 mm thick) on an epoxy resin bone model. The denture base was reduced by 5 mm cutting part of both the retromolar pad and the lingual border. Loads of up to 5 kg were applied, and the pressure and displacement of the RPDs were simultaneously measured and analyzed using the Wilcoxon test (αremovable partial denture (ISRPD) was significantly less than on the conventional RPD (CRPD). As the supporting area of the denture base decreased, the pressure and the denture displacement of the CRPD were greater than for the ISRPD. This study indicated that implant placement at the distal edentulous ridge can prevent denture displacement of the distal extension bases, regardless of the supporting area of the denture base. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. Strain gauge analysis of the effect of porcelain firing simulation on the prosthetic misfit of implant-supported frameworks.

    De Vasconcellos, Diego Klee; Özcan, Mutlu; Maziero Volpato, Cláudia Ângela; Bottino, Marco Antonio; Yener, Esra Salihoğlu

    2012-06-01

    This study investigated the effect of porcelain firing on the misfit of implant-supported frameworks and analyzed the influence of preheat treatment on the dimensional alterations. Four external-hex cylindrical implants were placed in polyurethane block. Ten frameworks of screw-retained implant-supported prostheses were cast in Pd-Ag using 2 procedures: (1) control group (CG, n = 5): cast in segments and laser welded; and test group (TG, n = 5): cast in segments, preheated, and laser welded. All samples were subjected to firing to simulate porcelain veneering firing. Strain gauges were bonded around the implants, and microstrain values (με = 10⁻⁶ε) were recorded after welding (M1), oxidation cycle (M2), and glaze firing (M3). Data were statistically analyzed (2-way analysis of variance, Bonferroni, α = 0.05). The microstrain value in the CG at M3 (475.2 με) was significantly different from the values observed at M1 (355.6 με) and M2 (413.9 με). The values at M2 and M3 in the CG were not statistically different. Microstrain values recorded at different moments (M1: 361.6 με/M2: 335.3 με/M3: 307.2 με) did not show significant difference. The framework misfit deteriorates during firing cycles of porcelain veneering. Metal distortion after porcelain veneering could be controlled by preheat treatment.

  4. The impact on bone tissues of immediate implant-supported mandibular overdentures with cusped and cuspless teeth

    Khalid A. Arafa

    2016-01-01

    Full Text Available Objectives: To examine the effects on bone tissues of immediate implant-supported mandibular overdentures with cusped or cuspless teeth. Methods: A randomized controlled trial was conducted at the Dental Clinic, Faculty of Dentistry, Al-Azhar University, Assiut Branch, Egypt, over a 12-month period from September 2013 to September 2014. Twenty patients were treated with immediate implant-supported overdentures: one group received overdentures with cusped teeth, and the other group received overdentures with cuspless teeth. The rate of implant success was assessed clinically and radiographically at 3, 6, 9, and 12 months. The data were collected by a questionnaire, an observation checklist, and radiography. The data were then analyzed using computerized methods. Results: Overdentures with cusped teeth showed a significant improvement in the clinical criteria, including the absence of clinical implant mobility, pain, and bone resorption, while the clinical criteria for the absence of peri-implant radiolucency were insignificantly different between the 2 groups (p>0.05. There were no significant differences in the clinical evaluations for bone levels at the time of insertion or 3 months after insertions, while significant differences were found at 6, 9, and 12 months after insertion. Conclusion: Overdentures with cusped teeth supported by immediate implants were found superior regarding many clinical criteria than those cuspless counterparts.

  5. The impact on bone tissues of immediate implant-supported mandibular overdentures with cusped and cuspless teeth.

    Arafa, Khalid A

    2016-01-01

    To examine the effects on bone tissues of immediate implant-supported mandibular overdentures with cusped or cuspless teeth. A randomized controlled trial was conducted at the Dental Clinic, Faculty of Dentistry, Al-Azhar University, Assiut Branch, Egypt, over a 12-month period from September 2013 to September 2014. Twenty patients were treated with immediate implant-supported overdentures: one group received overdentures with cusped teeth, and the other group received overdentures with cuspless teeth. The rate of implant success was assessed clinically and radiographically at 3, 6, 9, and 12 months. The data were collected by a questionnaire, an observation checklist, and radiography. The data were then analyzed using computerized methods.  Overdentures with cusped teeth showed a significant improvement in the clinical criteria, including the absence of clinical implant mobility, pain, and bone resorption, while the clinical criteria for the absence of peri-implant radiolucency were insignificantly different between the 2 groups (p more than 0.05). There were no significant differences in the clinical evaluations for bone levels at the time of insertion or 3 months after insertions, while significant differences were found at 6, 9, and 12 months after insertion. Overdentures with cusped teeth supported by immediate implants were found superior regarding many clinical criteria than those cuspless counterparts.

  6. The Effects on the Operating Condition of a Passenger Ship Retro-fitted with a Composite Superstructure

    Karatzas, Vasileios; Hjørnet, N. K.; Kristensen, Hans Otto Holmegaard

    2016-01-01

    As sustainability and climate change have come on the politi-cal agenda, the shipping industry will have to be operating energy efficient ships. An appealing step to achieve this goal is by designing superstructures made out of Fiber Reinforced Plastics (FRP) aiming at the reduction of the ship......’s lightship weight. The benefits of a light superstructure become most prominent in large passenger ships, as the superstructures constitute a significant percentage of the lightship. Additional-ly, depending on the size of the ship, the superstructure may tower several decks above the weather deck, affecting...

  7. Quality of Life of Patients Treated With Implant-Supported Mandibular Overdentures Evaluated With the Oral Health Impact Profile (OHIP-14: a Survey of 58 Patients

    Ritva Kuoppala

    2013-06-01

    Full Text Available Objectives: The purpose of this study was to evaluate the oral health-related quality of life of patients treated with implant-supported mandibular overdentures and to compare the attachment systems used.Material and Methods: Altogether 112 patients treated with implant-supported mandibular overdentures in 1985 - 2004 were invited to the follow-up; 58 of them attended and replied to the Oral Health Impact Profile (OHIP-14 -questionnaire. There were 48 overdentures with a bar connection and 10 with a ball connection, the total number of implants installed and still in use was 197. The mean follow-up time was 13.7 years. The associations between the OHIP-14 variables and the patient’s age, gender as well as the number of implants supporting the overdenture and the type of attachment used were assessed.Results: The results showed that patients with implant-supported mandibular overdentures were satisfied with their oral health-related quality of life (OHRQoL. Older patients were more satisfied than younger ones in both genders. Neither the implant connection type nor the number of supporting implants seemed to have a significant influence on the OHRQoL.Conclusions: Especially older patients with mandibular implant-supported overdentures were satisfied with their oral health-related quality of life. Attachment type or the number of supporting implants did not have a significant influence on the oral health-related quality of life.

  8. Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results.

    Esquivel-Upshaw, Josephine F; Clark, Arthur E; Shuster, Jonathan J; Anusavice, Kenneth J

    2014-02-01

    The aim of this study was to determine the survival rates over time of implant-supported ceramic-ceramic and metal-ceramic prostheses as a function of core-veneer thickness ratio, gingival connector embrasure design, and connector height. An IRB-approved, randomized, controlled clinical trial was conducted as a single-blind pilot study involving 55 patients missing three teeth in either one or two posterior areas. These patients (34 women; 21 men; age range 52-75 years) were recruited for the study to receive a three-unit implant-supported fixed dental prosthesis (FDP). Two implants were placed for each of the 72 FDPs in the study. The implants (Osseospeed, Astra Tech), which were made of titanium, were grit blasted. A gold-shaded, custom-milled titanium abutment (Atlantis, Astra Tech), was secured to each implant body. Each of the 72 FDPs in 55 patients were randomly assigned based on one of the following options: (1) A. ceramic-ceramic (Yttria-stabilized zirconia core, pressable fluorapatite glass-ceramic, IPS e.max ZirCAD, and ZirPress, Ivoclar Vivadent) B. metal-ceramic (palladium-based noble alloy, Capricorn, Ivoclar Vivadent, with press-on leucite-reinforced glass-ceramic veneer, IPS InLine POM, Ivoclar Vivadent); (2) occlusal veneer thickness (0.5, 1.0, and 1.5 mm); (3) curvature of gingival embrasure (0.25, 0.5, and 0.75 mm diameter); and (4) connector height (3, 4, and 5 mm). FDPs were fabricated and cemented with dual-cure resin cement (RelyX, Universal Cement, 3M ESPE). Patients were recalled at 6 months, 1 year, and 2 years. FDPs were examined for cracks, fracture, and general surface quality. Recall exams of 72 prostheses revealed 10 chipping fractures. No fractures occurred within the connector or embrasure areas. Two-sided Fisher's exact tests showed no significant correlation between fractures and type of material system (p = 0.51), veneer thickness (p = 0.75), radius of curvature of gingival embrasure (p = 0.68), and connector height (p = 0

  9. A novel ethanol templating synthesis of ordered lamellar superstructured crystalline zirconia

    Liu Chao, E-mail: liuchao_tj@yahoo.com; Wang Bin [Key Laboratory for New Type of Functional Materials in Hebei Province, Hebei University of Technology (China); Ji Xiujie, E-mail: jxjchem@yahoo.com [State Key Laboratory of Hollow Fiber Membrane Materials and Processes, Tianjin Polytechnic University (China); Zhao Shanshan; Wu Jie; Jia Jianlong; Ma Dongxia [Key Laboratory for New Type of Functional Materials in Hebei Province, Hebei University of Technology (China)

    2012-03-15

    Soft template technique has attracted great interest, because it is a facile, inexpensive and efficient synthesis strategy for ordered superstructural systems. Here, a novel ethanol template was used to synthesize the ordered lamellar superstructured crystalline zirconia (L{alpha}-ZrO{sub 2}) without post-treatments and surfactants. ZrOCl{sub 2} and NaOH were served as Zr source and precipitant, respectively. XRD analysis showed that L{alpha}-ZrO{sub 2} is crystalline. XPS spectra indicated the physical adsorption of ethanol molecules in L{alpha}-ZrO{sub 2}. TEM further observed and proved the 1.36-nm period of superstructure detected and calculated by SAXRD (1.35 nm), which is composed of 0.68-nm thick ZrO{sub 2} and pore alternatively. In contrast, the template-free ZrO{sub 2} (TF-ZrO{sub 2}) presents no superstructure and is poorly crystallized. As a soft template, ethanol presents the roles of (i) inducing the growth of zirconia layers, (ii) directing the self-assembly of ordered lamellar superstructure, and (iii) decreasing the crystallization temperature. The possible mechanism of ethanol serving as a soft template was proposed and discussed in thermodynamics.

  10. A novel ethanol templating synthesis of ordered lamellar superstructured crystalline zirconia

    Liu Chao; Wang Bin; Ji Xiujie; Zhao Shanshan; Wu Jie; Jia Jianlong; Ma Dongxia

    2012-01-01

    Soft template technique has attracted great interest, because it is a facile, inexpensive and efficient synthesis strategy for ordered superstructural systems. Here, a novel ethanol template was used to synthesize the ordered lamellar superstructured crystalline zirconia (Lα-ZrO 2 ) without post-treatments and surfactants. ZrOCl 2 and NaOH were served as Zr source and precipitant, respectively. XRD analysis showed that Lα-ZrO 2 is crystalline. XPS spectra indicated the physical adsorption of ethanol molecules in Lα-ZrO 2 . TEM further observed and proved the 1.36-nm period of superstructure detected and calculated by SAXRD (1.35 nm), which is composed of 0.68-nm thick ZrO 2 and pore alternatively. In contrast, the template-free ZrO 2 (TF-ZrO 2 ) presents no superstructure and is poorly crystallized. As a soft template, ethanol presents the roles of (i) inducing the growth of zirconia layers, (ii) directing the self-assembly of ordered lamellar superstructure, and (iii) decreasing the crystallization temperature. The possible mechanism of ethanol serving as a soft template was proposed and discussed in thermodynamics.

  11. Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model

    Ipsha Singh

    2017-01-01

    Full Text Available Aim: The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. Materials and Methods: A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. University of California, Los Angeles, abutment was attached to the implant fixture. Eight strain gauges were attached to the acrylic resin model. Six similar models were made. Implant-supported screw-retained fixed prosthesis was fabricated in nickel-chromium alloy. A load of 400 N was applied on the prosthesis using universal testing machine. Resultant strain was measured in each strain gauge. All the prostheses were sectioned at the area between 36 and 33, 33 and 43, and 43 and 46 using 35 micrometer carborundum disc, and strain was measured in each strain gauge after applying a load of 400 N on the prosthesis. Specimens were joined by arc welding, soldering, and laser welding. After joining, a load of 400 N was applied on each prosthesis and the resultant strain was measured in each strain gauge. Results: Highest mean strain values were recorded before sectioning of the prostheses (889.9 microstrains. Lowest mean strain values were recorded after sectioning the prosthesis and before reuniting it (225.0 microstrains. Conclusions: Sectioning and reuniting the long-span implant prosthesis was found to be a significant factor in influencing the peri-implant strain.

  12. Oral health-related quality of life in patients treated by implant-supported fixed dentures and removable partial dentures.

    Furuyama, Chisako; Takaba, Masayuki; Inukai, Mika; Mulligan, Roseann; Igarashi, Yoshimasa; Baba, Kazuyoshi

    2012-08-01

    This study investigated the association between denture status [implant-supported fixed dentures (IDs) and removable partial dentures (RPDs)] and oral health-related quality of life (OHRQoL). Consecutive patients with IDs and RPDs were recruited from the Prosthodontics Departments at Showa University and Tokyo Medical and Dental University. The Japanese version of the Oral Health Impact Profile (OHIP-J-49) was administered to each subject. For each OHIP-J-49 question, the subjects were asked to indicate the frequency with which they had experienced a dental problem during the last month. Responses were recorded on a 5 point Likert rating scale, with 0 being never and 4, very often. Summary scores were calculated and regression analyses conducted to investigate the association between denture status and OHIP-J-49 summary score. In total 79 ID subjects (mean age±SD of 51.7±12.4 years, 44.3% men) and 109 RPD subjects (mean age of 66.5±8.6 years, 30% men) participated after giving informed consent. The regression analysis between the type of treatment and the OHIP-J-49 summary score revealed a significant association with a coefficient of 17.0 (Confidence interval, CI: 10.9-23.1). When age and duration of denture usage, which had significant associations with OHIP-J-49, were included in this model, the regression coefficient remained virtually unchanged at 17.4 (CI: 9.75-25.0), thus indicating little potential confounding by them. OHRQoL in patients with implant-supported fixed dentures is generally less impaired than it is in those patients with RPDs. © 2011 John Wiley & Sons A/S.

  13. Effects of framework design and layering material on fracture strength of implant-supported zirconia-based molar crowns.

    Kamio, Shingo; Komine, Futoshi; Taguchi, Kohei; Iwasaki, Taro; Blatz, Markus B; Matsumura, Hideo

    2015-12-01

    To evaluate the effects of framework design and layering material on the fracture strength of implant-supported zirconia-based molar crowns. Sixty-six titanium abutments (GingiHue Post) were tightened onto dental implants (Implant Lab Analog). These abutment-implant complexes were randomly divided into three groups (n = 22) according to the design of the zirconia framework (Katana), namely, uniform-thickness (UNI), anatomic (ANA), and supported anatomic (SUP) designs. The specimens in each design group were further divided into two subgroups (n = 11): zirconia-based all-ceramic restorations (ZAC group) and zirconia-based restorations with an indirect composite material (Estenia C&B) layered onto the zirconia framework (ZIC group). All crowns were cemented on implant abutments, after which the specimens were tested for fracture resistance. The data were analyzed with the Kruskal-Wallis test and the Mann-Whitney U-test with the Bonferroni correction (α = 0.05). The following mean fracture strength values (kN) were obtained in UNI design, ANA design, and SUP design, respectively: Group ZAC, 3.78, 6.01, 6.50 and Group ZIC, 3.15, 5.65, 5.83. In both the ZAC and ZIC groups, fracture strength was significantly lower for the UNI design than the other two framework designs (P = 0.001). Fracture strength did not significantly differ (P > 0.420) between identical framework designs in the ZAC and ZIC groups. A framework design with standardized layer thickness and adequate support of veneer by zirconia frameworks, as in the ANA and SUP designs, increases fracture resistance in implant-supported zirconia-based restorations under conditions of chewing attrition. Indirect composite material and porcelain perform similarly as layering materials on zirconia frameworks. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model.

    Singh, Ipsha; Nair, K Chandrasekharan; Shetty, Jayakar

    2017-01-01

    The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. University of California, Los Angeles, abutment was attached to the implant fixture. Eight strain gauges were attached to the acrylic resin model. Six similar models were made. Implant-supported screw-retained fixed prosthesis was fabricated in nickel-chromium alloy. A load of 400 N was applied on the prosthesis using universal testing machine. Resultant strain was measured in each strain gauge. All the prostheses were sectioned at the area between 36 and 33, 33 and 43, and 43 and 46 using 35 micrometer carborundum disc, and strain was measured in each strain gauge after applying a load of 400 N on the prosthesis. Specimens were joined by arc welding, soldering, and laser welding. After joining, a load of 400 N was applied on each prosthesis and the resultant strain was measured in each strain gauge. Highest mean strain values were recorded before sectioning of the prostheses (889.9 microstrains). Lowest mean strain values were recorded after sectioning the prosthesis and before reuniting it (225.0 microstrains). Sectioning and reuniting the long-span implant prosthesis was found to be a significant factor in influencing the peri-implant strain.

  15. Motor behavior during the first chewing cycle in subjects with fixed tooth- or implant-supported prostheses.

    Grigoriadis, Joannis; Trulsson, Mats; Svensson, Krister G

    2016-04-01

    Appropriate sensory information from periodontal mechanoreceptors (PMRs) is important for optimizing the positioning of food and adjustment of force vectors during precision biting. This study was designed to describe motor behavior during the first cycle of a natural chewing task and to evaluate the role of such sensory input in this behavior. While 10 subjects with natural dentition, 11 with bimaxillary fixed tooth-supported prostheses (TSP) and 10 with bimaxillary fixed implant-supported prostheses (ISP) (mean age 69 [range 61-83]) chewed a total of five hazelnuts, their vertical and lateral jaw movements were recorded. Data obtained during the first chewing cycle of each hazelnut were analyzed. The amplitude of vertical and lateral mandibular movement and duration of jaw opening did not differ between the groups, indicating similar behavior during this part of the chewing cycle. However, only 30% of the subjects in the natural dentate group, but 82% of those in the TSP and 70% in the ISP group exhibited slippage of the hazelnut during jaw closure in at least one of five trials. The TSP and ISP groups also exhibited more irregular and narrower patterns of motion (total lateral/vertical movement = 0.15 and 0.19, respectively, compared to 0.27 for the natural group). Subjects with fixed tooth- or implant-supported prostheses in both jaws show altered behavior, including inadequate control of the hazelnut, during the first chewing cycle. We propose that these differences are due to impairment or absence of sensory signaling from PMRs in these individuals. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Influence of Abutment Design on Stiffness, Strength, and Failure of Implant-Supported Monolithic Resin Nano Ceramic (RNC) Crowns.

    Joda, Tim; Huber, Samuel; Bürki, Alexander; Zysset, Philippe; Brägger, Urs

    2015-12-01

    Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation. © 2014 Wiley Periodicals, Inc.

  17. Fracture Resistance and Mode of Failure of Ceramic versus Titanium Implant Abutments and Single Implant-Supported Restorations.

    Sghaireen, Mohd G

    2015-06-01

    The material of choice for implant-supported restorations is affected by esthetic requirements and type of abutment. This study compares the fracture resistance of different types of implant abutments and implant-supported restorations and their mode of failure. Forty-five Oraltronics Pitt-Easy implants (Oraltronics Dental Implant Technology GmbH, Bremen, Germany) (4 mm diameter, 10 mm length) were embedded in clear autopolymerizing acrylic resin. The implants were randomly divided into three groups, A, B and C, of 15 implants each. In group A, titanium abutments and metal-ceramic crowns were used. In group B, zirconia ceramic abutments and In-Ceram Alumina crowns were used. In group C, zirconia ceramic abutments and IPS Empress Esthetic crowns were used. Specimens were tested to failure by applying load at 130° from horizontal plane using an Instron Universal Testing Machine. Subsequently, the mode of failure of each specimen was identified. Fracture resistance was significantly different between groups (p Empress crowns supported by zirconia abutments had the lowest fracture loads (p = .000). Fracture modes of metal-ceramic crowns supported by titanium abutments included screw fracture and screw bending. Fracture of both crown and abutment was the dominant mode of failure of In-Ceram/IPS Empress crowns supported by zirconia abutments. Metal-ceramic crowns supported by titanium abutments were more resistant to fracture than In-Ceram crowns supported by zirconia abutments, which in turn were more resistant to fracture than IPS Empress crowns supported by zirconia abutments. In addition, failure modes of restorations supported by zirconia abutments were more catastrophic than those for restorations supported by titanium abutments. © 2013 Wiley Periodicals, Inc.

  18. A comparison of the accuracy of polyether, polyvinyl siloxane, and plaster impressions for long-span implant-supported prostheses.

    Hoods-Moonsammy, Vyonne J; Owen, Peter; Howes, Dale G

    2014-01-01

    The purpose of this study was to compare the capacity of different impression materials to accurately reproduce the positions of five implant analogs on a master model by comparing the resulting cast with the stainless steel master model. The study was motivated by the knowledge that distortions can occur during impression making and the pouring of casts and that this distortion may produce inaccuracies of subsequent restorations, especially long-span castings for implant superstructures. The master model was a stainless steel model with five implant analogs. The impression materials used were impression plaster (Plastogum, Harry J Bosworth), a polyether (Impregum Penta, 3M ESPE), and two polyvinyl siloxane (PVS) materials (Aquasil Monophase and Aquasil putty with light-body wash, Dentsply). Five impressions were made with each impression material and cast in die stone under strictly controlled laboratory conditions. The positions of the implants on the master model, the impression copings, and the implant analogs in the subsequent casts were measured using a coordinate measuring machine that measures within 4 μm of accuracy. Statistical analyses indicated that distortion occurred in all of the impression materials, but inconsistently. The PVS monophase material reproduced the master model most accurately. Although there was no significant distortion between the impressions and the master model or between the impressions and their casts, there were distortions between the master model and the master casts, which highlighted the cumulative effects of the distortions. The polyether material proved to be the most reliable in terms of predictability. The impression plaster displayed cumulative distortion, and the PVS putty with light body showed the least reliability. Some of the distortions observed are of clinical significance and likely to contribute to a lack of passive fit of any superstructure. The inaccuracy of these analog materials and procedures suggested

  19. Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: A photoelastic stress analysis study.

    Lee, Jae-In; Lee, Yoon; Kim, Yu-Lee; Cho, Hye-Won

    2016-02-01

    The 4-, 3- or even 2-implant-supported partial fixed dental prosthesis (PFDP) designs have been used to rehabilitate the anterior edentulous maxilla. The purpose of this in vitro study was to compare the stress distribution in the supporting tissues surrounding implants placed in the anterior maxilla with 5 PFDP designs. A photoelastic model of the human maxilla with an anterior edentulous region was made with photoelastic resin (PL-2; Vishay Micro-Measurements), and 6 straight implants (OsseoSpeed; Astra Tech AB) were placed in the 6 anterior tooth positions. The 5 design concepts based on implant location were as follows: model 6I: 6 implants; model 2C2CI: 4 implants (2 canines and 2 central incisors); model 2C2LI: 4 implants (2 canines and 2 lateral incisors); model 2C1CI: 3 implants (2 canines and 1 central incisor); and model 2C: 2 canines. A load of 127.4 N was applied on the cingulum of 3 teeth at a 30-degree angle to the long axis of the implant. Stresses that developed in the supporting structure were recorded photographically. The 6-implant-supported PFDP exhibited the most even and lowest distribution of stresses in all loading conditions. When the canine was loaded, the 2- or 3-implant-supported PFDP showed higher stresses around the implant at the canine position than did the 4- or 6-implant-supported PFDP. When the central incisor or lateral incisor was loaded, the two 4-implant-supported PFDPs exhibited similar levels of stresses around the implants and showed lower stresses than did the 2- or 3-implant-supported PFDP. Implant number and distribution influenced stress distribution around the implants in the anterior maxilla. With a decrease in implant number, the stresses around the implants increased. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Turbulent Superstructures in Rayleigh-Bénard convection at different Prandtl number

    Schumacher, Jörg; Pandey, Ambrish; Ender, Martin; Westermann, Rüdiger; Scheel, Janet D.

    2017-11-01

    Large-scale patterns of the temperature and velocity field in horizontally extended cells can be considered as turbulent superstructures in Rayleigh-Bénard convection (RBC). These structures are obtained once the turbulent fluctuations are removed by a finite-time average. Their existence has been reported for example in Bailon-Cuba et al.. This large-scale order obeys a strong similarity with the well-studied patterns from the weakly nonlinear regime at lower Rayleigh number in RBC. In the present work we analyze the superstructures of RBC at different Prandtl number for Prandtl values between Pr = 0.005 for liquid sodium and 7 for water. The characteristic evolution time scales, the typical spatial extension of the rolls and the properties of the defects of the resulting superstructure patterns are analyzed. Data are obtained from well-resolved spectral element direct numerical simulations. The work is supported by the Priority Programme SPP 1881 of the Deutsche Forschungsgemeinschaft.

  1. Linking experiment and theory for three-dimensional networked binary metal nanoparticle–triblock terpolymer superstructures

    Li, Zihui

    2014-02-21

    © 2014 Macmillan Publishers Limited. Controlling superstructure of binary nanoparticle mixtures in three dimensions from self-assembly opens enormous opportunities for the design of materials with unique properties. Here we report on how the intimate coupling of synthesis, in-depth electron tomographic characterization and theory enables exquisite control of superstructure in highly ordered porous three-dimensional continuous networks from single and binary mixtures of metal nanoparticles with a triblock terpolymer. Poly(isoprene-block-styrene-block-(N,N-dimethylamino)ethyl methacrylate) is synthesized and used as structure-directing agent for ligand-stabilized platinum and gold nanoparticles. Quantitative analysis provides insights into short-and long-range nanoparticle-nanoparticle correlations, and local and global contributions to structural chirality in the networks. Results provide synthesis criteria for next-generation mesoporous network superstructures from binary nanoparticle mixtures for potential applications in areas including catalysis.

  2. Cryo-transmission electron microscopy of a superstructure of fluid dioleoylphosphatidylcholine (DOPC) membranes

    Klösgen, B; Helfrich, W

    1997-01-01

    a porous technical membrane. Sampling and cryofixation took place at various times within 3 weeks after the preparation. From the micrographs we infer that the small fraction of vesicles enclosing one another develop passages (connections) between the bilayers. In contrast, the superstructure is basically...... a feature of disconnected membranes. Among its modifications are isolated membrane bends or folds and a grainy membrane texture with a minimal grain spacing of 4-6 nm. In the extruded dispersions the passages and the superstructure seem to be formed mostly within the first day. The fraction of smooth...

  3. Antiphase boundaries, inversion, and ferroelastic domains in the striped-type superstructure of γ-brass Cu-Al alloys

    Koyama, Y.; Hatano, M.; Tanimura, M.

    1996-05-01

    Features of the striped-type superstructure in γ-brass Cu-Al alloys have been investigated mainly by transmission electron microscopy in order to understand the role of a rhombohedral distortion in its stability. From dark field images taken from alloys exhibiting the superstructure, it was found that there exist two types of ferroelastic rhombohedral domains, which are in a twin relation. In other words, the superstructure is characterized by a periodic array of the ferroelastic domains as well as inversion antiphase boundaries. Because charge density waves should be responsible for the formation of the superstructure, as suggested in our previous paper [Phys. Rev. B 40, 5378 (1989)], the rhombohedral distortion must play a crucial role in their appearance. Presumably the distortion enlarges parallel portions of the Fermi surface. On the basis of the present experimental data, the interplay between the striped-type superstructure and the rhombohedral γ-brass structure is also discussed.

  4. Treatment Outcome of Two Adjacent Implant-Supported Restorations with Different Implant Platform Designs in the Esthetic Region : A Five-Year Randomized Clinical Trial

    Van Nimwegen, Wouter G.; Raghoebar, Gerry M.; Stellingsma, Kees; Tymstra, Nynke; Vissink, Arjan; Meijer, Henny J. A.

    Purpose: The aim of this study was to evaluate the peri-implant soft and hard tissues and satisfaction in patients with two adjacent implant-supported restorations in the esthetic region, treated with two adjacent implants with a scalloped or flat platform. Materials and Methods: The randomized

  5. Evaluation of aesthetics of implant-supported single-tooth replacements using different bone augmentation procedures : A prospective randomized clinical study

    Meijndert, Leo; Meijer, Henny J. A.; Stellingsma, Kees; Stegenga, Boudewijn; Raghoebar, Gerry M.

    2007-01-01

    Objectives: The aim of this study was to evaluate the aesthetics of implant-supported single-tooth replacements using different augmentation procedures in a prospective study with the use of an objective rating index and with a subjective patient questionnaire, and to compare the results with each

  6. Full mouth rehabilitation with retrievable metal-ceramic implant-supported fixed prostheses for a young patient with atrophic jaws: a clinical report.

    Ameri, Narges; Alikhasi, Marzieh; Rezayani, Vida

    2017-09-01

    Treatment of atrophic edentulous jaws with implant-supported fixed prostheses is one of the most complicated challenges in dentistry. This clinical report describes the prosthesis which consists of screw retained frameworks with individual cement retained crowns which combines the advantages of the screw retained restoration with the advantage of cement retained.

  7. Complications and patient-centered outcomes with an implant-supported monolithic zirconia fixed dental prosthesis: 1 year results.

    Limmer, Bryan; Sanders, Anne E; Reside, Glenn; Cooper, Lyndon F

    2014-06-01

    To characterize the number and type of complications that occur with a monolithic zirconia fixed dental prosthesis (MZ-FDP) supported by four endosseous implants in the edentulous mandible over time and to quantify the impact of treatment on oral health quality of life (OHQoL). Seventeen edentulous participants were enrolled. New conventional dentures were fabricated for each participant. Four Astra Tech Osseospeed TX implants (Dentsply) were then placed in the parasymphyseal mandible, and after a period of healing, a full-arch monolithic zirconia prosthesis (Zirkonzahn) was inserted. Complication data were recorded and OHQoL was evaluated using the Oral Health Impact Profile (OHIP-49), administered on four occasions: enrollment; implant surgery; and 6- and 12-month recalls. Sixty-eight implants were placed in 17 edentulous individuals aged 30 to 78 (mean 57.9 years). Implant survival was 94% from the subject perspective and 99% from the implant perspective. Prosthesis survival was 88%. Twelve complications occurred in ten participants, whereas seven participants remained complication free. Both OHIP-49 severity and extent scores decreased significantly between enrollment and 12-month recall (p < 0.001). The mean OHIP-49 severity score at baseline was 94.8 (95% confidence interval [CI]: 73.9, 115.8) and declined an average of 76.8 (95% CI: -91.3, -62.3) units per participant. The mean OHIP-49 extent score at baseline was 17.2 (95% CI: 10.8, 23.6) and declined 16.3 (95% CI: -20.2, -12.4) units per participant on average. Implant survival was high, and few complications related to the MZ-FDP were observed. The most common prosthetic complication was tooth chipping in the opposing maxillary denture, which accounted for 50% of all complication events. Substantial and clinically important improvements in OHQoL were achieved with both conventional dentures and the implant-supported MZ-FDP. The data of this short-term study indicate that the implant-supported MZ-FDP is a

  8. Experimental Study of Properties of Pervious Concrete used for Bridge Superstructure

    Lund, Mia Schou Møller; Hansen, Kurt Kielsgaard; Hertz, Kristian Dahl

    2014-01-01

    around freezing point are exposed to a harsh freeze-thaw impact, since bridges are not only cooled from the topside, as a normal road bed, but also from underneath. Hence, the demands to the moisture properties of the superstructure are strict in order to ensure the necessary durability. Pearl...

  9. Erection of the Rokko island bridge superstructure. Rokko island kyojobu koji no seko

    Tanino, A; Sakai, Y; Morikawa, Y; Sakoda, H; Egami, T; Maeda, Y; Shikata, H; Miyazaki, K [Kawasaki Heavy Industries, Ltd., Tokyo (Japan)

    1993-10-20

    Erection of the superstructure of the Rokko Island Bridge (220 m long) was outlined which connects Rokko Island with Kobe City. The weight of the superstructure was nearly 7,300 tons, the highest single weight of any unit bridge structures ever installed in Japan. Because various ships cruised at the erection site every day, the superstructure was assembled and painted in a factory, and after shipped to its destination on a large barge, it was hoisted onto the previously constructed piers by three giant floating cranes (FC). Since it was most essential to match hook loads among the FCs, the hook load control system was developed in which hook load data of each FC were sent to a control center every 4-5 seconds by wireless transmission, and the data as well as their required control limits were graphically displayed to support a situation recognition, resulting in rapid and safe erection. The erection work started from that of piers in Aug. 1992, and that of the superstructure started in Nov. 1992 and ended in Feb. 1993. 13 figs., 4 tabs.

  10. Self-assembly of polyhedral metal–organic framework particles into three-dimensional ordered superstructures

    Avci, Civan; Imaz, Inhar; Carné-Sánchez, Arnau; Pariente, Jose Angel; Tasios, Nikos; Pérez-Carvajal, Javier; Alonso, Maria Isabel; Blanco, Alvaro; Dijkstra, M.; López, Cefe; Maspoch, Daniel

    Self-assembly of particles into long-range, three-dimensional, ordered superstructures is crucial for the design of a variety of materials, including plasmonic sensing materials, energy or gas storage systems, catalysts and photonic crystals. Here, we have combined experimental and simulation data

  11. Role of Steric Hindrance in the Crystal Packing of Z′ = 4 Superstructure of Trimethyltin Hydroxide

    Dey, S.

    2018-01-22

    The roomerature crystal structure of trimethyltin hydroxide, (CH)SnOH, has been described by Anderson et al. [Cryst. Growth Des. 2011, 11, 820-826] as a 2a × 2b × 8c, 32-fold superstructure. We report a a × b × 8c, eight-fold superstructure with orthorhombic P2cn symmetry and Z′ = 4. Structured diffuse scattering observed at the positions of presumed superlattice reflections along a∗ and b∗ might have appeared as Bragg reflections in the experiment by Anderson et al. Alternatively, Anderson et al. and the present work might have studied different polymorphs of (CH)SnOH. Crystalline (CH)SnOH constitutes polymeric chains arranged parallel to c. In the eight-fold superstructure at 220 K, the polymeric chains possess a distorted zigzag arrangement of linked linear O-Sn-O units with bent angle at oxygen of ∼139.2°. This structure is essentially different from the 8-helical arrangement in the published 32-fold superstructure model. The origin of the distorted zigzag structure is explained by steric hindrance between hydrogen atoms of adjacent hydroxy groups and (CH)Sn groups. Frustration in the packing of the chains is determined by steric hindrance between methyl groups of neighboring chains, which prevents the formation of interchain C-H···O hydrogen bonds.

  12. Globalisation in Africa: Reflecting on Peter Jarvis's Superstructure and Substructure Model

    Preece, Julia

    2017-01-01

    This paper reflects on Peter Jarvis' book "Globalisation, lifelong learning and the learning society," volume 2--in which he describes human learning within a global context and factors contributing to globalisation. He describes the relationship of power between countries manifested as the superstructure and sub structure. The paper…

  13. Unknown Aspects of Self-Assembly of PbS Microscale Superstructures

    Querejeta-Fernández, Ana; Hernández-Garrido, Juan C.; Yang, Hengxi; Zhou, Yunlong; Varela, Aurea; Parras, Marina; Calvino-Gámez, José J.; González-Calbet, Jose M.; Green, Peter F.; Kotov, Nicholas A.

    2012-01-01

    A lot of interesting and sophisticated examples of nanoparticle (NP) self-assembly (SA) are known. From both fundamental and technological standpoints this field requires advancements in three principle directions: a) understanding the mechanism and driving forces of three-dimensional (3D) SA with both nano- and micro-levels of organization; b) understanding of disassembly/deconstruction processes; and c) finding synthetic methods of assembly into continuous superstructures without insulating barriers. From this perspective, we investigated the formation of well-known star-like PbS superstructures and found a number of previously unknown or overlooked aspects that can advance the knowledge of NP self-assembly in these three directions. The primary one is that the formation of large seemingly monocrystalline PbS superstructures with multiple levels of octahedral symmetry can be explained only by SA of small octahedral NPs. We found five distinct periods in the formation PbS hyperbranched stars: 1) nucleation of early PbS NPs with an average diameter of 31 nm; 2) assembly into 100–500 nm octahedral mesocrystals; 3) assembly into 1000–2500 nm hyperbranched stars; 4) assembly and ionic recrystallization into six-arm rods accompanied by disappearance of fine nanoscale structure; 5) deconstruction into rods and cubooctahedral NPs. The switches in assembly patterns between the periods occur due to variable dominance of pattern–determining forces that include vander Waals and electrostatic (charge-charge, dipole-dipole, and polarization) interactions. The superstructure deconstruction is triggered by chemical changes in the deep eutectic solvent (DES) used as the media. PbS superstructures can be excellent models for fundamental studies of nanoscale organization and SA manufacturing of (opto)electronics and energy harvesting devices which require organization of PbS components at multiple scales. PMID:22515512

  14. Emerging Technologies: E-Textbooks, One Piece of the Puzzle

    Wiese, Melanie; Du Plessis, Giselle

    2017-01-01

    The Internet has not only brought about a new technological era, but also seen the introduction of a number of emerging technologies such as e-textbooks. However, the slow acceptance of e-textbooks is an issue of concern. The objective of this study is to investigate students' perceptions and use of e-textbooks. Data was collected by using a…

  15. Analisis Pesan Moral Dalam Komik One Piece Karya Eiichiro Oda

    Syafitri, Muhammad

    2013-01-01

    Sastra adalah ekspresi diri kehidupan dengan media bahasa yang khas. Sastra merupakan tulisan bernilai seni mengenai suatu objek, khususnya kehidupan manusia dalam suatu negeri pada suatu masa. Suatu karya sastra selain mengandung unsur hiburan, juga mengandung unsur pendidikan dan pengajaran. Sebuah karya sastra fiksi ditulis oleh pengarang anatara lain untuk menawarkan model kehidupan yang diidealkan. Karya sastra dibedakan atas puisi, drama, dan prosa. Prosa merupakan jenis karya sastra be...

  16. Maxillary arch rehabilitation using implant-supported computer-assisted design-computer-assisted manufacturing-milled titanium framework

    Tulika S Khanna

    2017-01-01

    Full Text Available Esthetic and functional rehabilitation of completely edentulous maxillary arch with fixed implant supported prosthesis is a challenging task. Newer technologies such as computer assisted design computer assisted manufacturing (CAD CAM and cone beam conventional tomography play an important role in achieving predictable results. Full mouth porcelain fused to metal (PFM individual crowns on CAD CAM milled titanium framework provides positive esthetic and functional outcome. This is a case report of rehabilitation of partially edentulous maxillary arch patient. Staged rehabilitation of this patient was planned. In the first stage, root canal treatment of key abutment teeth was done, nonsalvageable teeth were removed, and immediate interim overdenture was provided. In the second stage, five Nobel Biocare dental implants were placed. After integration impressions were made, CAD CAM milled titanium bar was fabricated. Individual PFM crowns were made and cemented. This method gives better esthetic compared to acrylic fused to metal hybrid prosthesis with the advantage of retrievability just like screw retained prosthesis. Hence, this technique is good for rehabilitation of patients with high esthetic demands.

  17. Comparative three-dimensional finite element analysis of implant-supported fixed complete arch mandibular prostheses in two materials.

    Tribst, João Paulo Mendes; de Morais, Dayana Campanelli; Alonso, Alexandre Abhdala; Piva, Amanda Maria de Oliveira Dal; Borges, Alexandre Luis Souto

    2017-01-01

    The increase of requests for implant-supported prosthesis (ISP) with zirconia as infrastructure has attracted a lot of attention due to its esthetics, biocompatibility, and survival rate similar to metallic infrastructure. The aim of this study was to evaluate the influence of two different framework materials on stress distribution over a bone tissue-simulating material. Two ISP were modeled and divided into two infrastructure materials: titanium (Ti) and zirconia. Then, these bars were attached to a modeled jaw with polyurethane properties to simulate bone tissue. An axial load of 200 N was applied on a standardized area for both systems. Maximum principal stress (MPS) on solids and microstrain (MS) generated through the jaw were analyzed by finite element analysis. According to MS, both models showed strains on peri-implant region of the penultimate (same side of the load application) and central implants. For MPS, more stress concentration was slightly higher in the left posterior region for Ti's bar. In prosthetic fixation screws, the MPS prevailed strongly in Ti protocol, while for zirconia's bar, the cervical of the penultimate implant was the one that highlighted larger areas of possible damages. The stress generated in all constituents of the system was not significantly influenced by the framework's material. This allows suggesting that in cases without components, the use of a framework in zirconia has biomechanical behavior similar to that of a Ti bar.

  18. The role of prosthetic abutment material on the stress distribution in a maxillary single implant-supported fixed prosthesis

    Peixoto, Hugo Eduardo; Bordin, Dimorvan; Del Bel Cury, Altair A.; Silva, Wander José da; Faot, Fernanda

    2016-01-01

    Purpose: Evaluate the influence of abutment's material and geometry on stress distribution in a single implant-supported prosthesis. Materials and Methods: Three-dimensional models were made based on tomographic slices of the upper middle incisor area, in which a morse taper implant was positioned and a titanium (Ti) or zirconia (ZrN) universal abutments was installed. The commercially available geometry of titanium (T) and zirconia (Z) abutments were used to draw two models, TM1 and ZM1 respectively, which served as control groups. These models were compared with 2 experimental groups were the mechanical properties of Z were applied to the titanium abutment (TM2) and vice versa for the zirconia abutment (ZM2). Subsequently, loading was simulated in two steps, starting with a preload phase, calculated with the respective friction coefficients of each materials, followed by a combined preload and chewing force. The maximum von Mises stress was described. Data were analyzed by two-way ANOVA that considered material composition, geometry and loading (p 0.05). Conclusion: The screw was the piece most intensely affected, mainly through the preload force, independent of the abutment's material. - Highlights: • The abutment's screw was the most impaired piece of the dental implant system. • The highest stress was located at first thread of the abutment's screw. • The preload is the main factor in the abutment's screw stress. • Abutment configuration and material can have a positive contribution for the stress distribution

  19. Stress analysis of different prosthesis materials in implant-supported fixed dental prosthesis using 3D finite element method

    Pedram Iranmanesh

    2014-01-01

    Full Text Available Introduction: In the present study, the finite element method (FEM was used to investigate the effects of prosthesis material types on stress distribution of the bone surrounding implants and to evaluate stress distribution in three-unit implant-supported fixed dental prosthesis (FDP. Materials and Methods: A three-dimensional (3D finite element FDP model of the maxillary second premolar to the second molar was designed. Three load conditions were statically applied on the functional cusps in horizontal (57.0 N, vertical (200.0 N, and oblique (400.0 N, θ = 120° directions. Four standard framework materials were evaluated: Polymethyl methacrylate (PMMA, base-metal, porcelain fused to metal, andporcelain. Results: The maximum of von Mises stress in the oblique direction was higher than the vertical and horizontal directions in all conditions. In the bone-crestal section, the maximum von Mises stress (53.78 MPa was observed in PMMA within oblique load. In FDPs, the maximum stress was generated at the connector region in all conditions. Conclusion: A noticeable difference was not observed in the bone stress distribution pattern with different prosthetic materials. Although, higher stress value could be seen in polymethyl methacrylate, all types of prosthesis yielded the same stress distribution pattern in FDP. More clinical studies are needed to evaluate the survival rate of these materials.

  20. Stress analysis on the free-end distal extension of an implant-supported mandibular complete denture

    Gustavo Diniz Greco

    2009-06-01

    Full Text Available A comparative and qualitative analysis of the tensions generated in the cantilever region of an implant-supported mandibular complete denture was conducted using the three-dimensional finite element method. The mechanical properties of the components were input in the model and a load of 15 N was applied in pre-determined points. In the first simulation, the load was applied on the occlusal surface of the first premolar. In the second simulation, it was applied on the first and second premolars. In the third simulation, it was applied on the first and second premolars and on the first molar. The different occlusion patterns produced similar tension distributions in the cantilever region, which followed a similar pattern in the three simulations. In all of the cases, the highest levels of tension were located in the region of the first implant. However, as the loads were dislocated distally, the tensions increased considerably. The more extensive the cantilever, the more compromised will be the infrastructure, the prosthetic components and the implants. Regardless of the length of the cantilever, the highest tensions will always be located in the region of the implant next to the load application point.

  1. The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional

    Seyyed Mohammad Abrisham

    2012-09-01

    Full Text Available Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI, 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughened with sandblast (50-µm aluminum oxide and in the second group, 10 abutments were roughened with diamond bur. The third group had no surface treatment. Then, thirty implant fixture analogs (ITI were placed in the center of acrylic cylinders. After that a solid abutment was tightened on the each fixture analog with 35 N/cm force. Thirty base metal crowns were made on the 4 mm ITI abutment analogs using plastic coping. The prepared copings were cemented on the abutments by TempBond temporary cement and finally, crowns were pulled from the abutment in a universal test machine at a cross speed of 0.5cm/min. Results: The mean tensile strength in sandblasted, bur treated, and control group were 64.38±8, 91.37±7.19, and 58.61±1.93, respectively. Bur treated group showed higher tensile strength in comparison with two other groups. Conclusion: Surface modification of implant abutment by diamond bur may be an effective method to increase retention of crown when TempBond is used.

  2. The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

    Jalil Ganbarzadeh

    2013-01-01

    Full Text Available Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI, 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughened with sandblast (50-µm aluminum oxide and in the second group, 10 abutments were roughened with diamond bur. The third group had no surface treatment. Then, thirty implant fixture analogs (ITI were placed in the center of acrylic cylinders. After that a solid abutment was tightened on the each fixture analog with 35 N/cm force. Thirty base metal crowns were made on the 4 mm ITI abutment analogs using plastic coping. The prepared copings were cemented on the abutments by TempBond temporary cement and finally, crowns were pulled from the abutment in a universal test machine at a cross speed of 0.5cm/min. Results: The mean tensile strength in sandblasted, bur treated, and control group were 64.38±8, 91.37±7.19, and 58.61±1.93, respectively. Bur treated group showed higher tensile strength in comparison with two other groups. Conclusion: Surface modification of implant abutment by diamond bur may be an effective method to increase retention of crown when TempBond is used.

  3. Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study

    Soumyadev Satpathy

    2015-01-01

    Full Text Available Aims and Objectives: The aim of this study was to asses & compare the load transfer characteristics of Ball/O-ring and Bar/Clip attachment systems in implant supported overdentures using analog and finite element analysis models. Methodology: For the analog part of the study, castable bar was used for the bar and clip attachment and a metallic housing with a rubber O-ring component was used for the ball/O-ring attachment. The stress on the implant surface was measured using the strain-gauge technique. For the finite element analysis, the model were fabricated and load applications were done in a similar manner as in analog study. Results: The difference between both the attachment systems was found to be statistically significant (P<0.001. Conclusion: Ball/O-ring attachment system transmitted lesser amount of stresses to the implants on the non-loading side, as compared to the Bar-Clip attachment system. When overall stress distribution is compared, the Bar-Clip attachment seems to perform better than the Ball/O-ring attachment, because the force was distributed better.

  4. Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis.

    Moris, Izabela C M; Monteiro, Silas Borges; Martins, Raíssa; Ribeiro, Ricardo Faria; Gomes, Erica A

    2018-01-01

    To evaluate the influence of different manufacturing methods of single implant-supported metallic crowns on the internal and external marginal fit through computed microtomography. Forty external hexagon implants were divided into 4 groups ( n = 8), according to the manufacturing method: GC, conventional casting; GI, induction casting; GP, plasma casting; and GCAD, CAD/CAM machining. The crowns were attached to the implants with insertion torque of 30 N·cm. The external (vertical and horizontal) marginal fit and internal fit were assessed through computed microtomography. Internal and external marginal fit data ( μ m) were submitted to a one-way ANOVA and Tukey's test ( α = .05). Qualitative evaluation of the images was conducted by using micro-CT. The statistical analysis revealed no significant difference between the groups for vertical misfit ( P = 0.721). There was no significant difference ( P > 0.05) for the internal and horizontal marginal misfit in the groups GC, GI, and GP, but it was found for the group GCAD ( P ≤ 0.05). Qualitative analysis revealed that most of the samples of cast groups exhibited crowns underextension while the group GCAD showed overextension. The manufacturing method of the crowns influenced the accuracy of marginal fit between the prosthesis and implant. The best results were found for the crowns fabricated through CAD/CAM machining.

  5. Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis

    Izabela C. M. Moris

    2018-01-01

    Full Text Available Aim. To evaluate the influence of different manufacturing methods of single implant-supported metallic crowns on the internal and external marginal fit through computed microtomography. Methods. Forty external hexagon implants were divided into 4 groups (n=8, according to the manufacturing method: GC, conventional casting; GI, induction casting; GP, plasma casting; and GCAD, CAD/CAM machining. The crowns were attached to the implants with insertion torque of 30 N·cm. The external (vertical and horizontal marginal fit and internal fit were assessed through computed microtomography. Internal and external marginal fit data (μm were submitted to a one-way ANOVA and Tukey’s test (α=.05. Qualitative evaluation of the images was conducted by using micro-CT. Results. The statistical analysis revealed no significant difference between the groups for vertical misfit (P=0.721. There was no significant difference (P>0.05 for the internal and horizontal marginal misfit in the groups GC, GI, and GP, but it was found for the group GCAD (P≤0.05. Qualitative analysis revealed that most of the samples of cast groups exhibited crowns underextension while the group GCAD showed overextension. Conclusions. The manufacturing method of the crowns influenced the accuracy of marginal fit between the prosthesis and implant. The best results were found for the crowns fabricated through CAD/CAM machining.

  6. Staged Hard and Soft Tissue Reconstruction Followed by Implant Supported Restoration in the Aesthetic Zone: A Case Report.

    Parthasarathy, Harinath; Ramachandran, Lakshmi; Tadepalli, Anupama; Ponnaiyan, Deepa

    2017-04-01

    Alveolar ridge deficiency is a common clinical consequence following tooth loss due to chronic periodontitis complicating ideal implant placement. Advanced hard and soft tissue augmentation procedures have been developed in the recent past with predictable clinical outcomes. A male patient presented with a Grade III mobile upper right central incisor associated with advanced bone loss and soft tissue deficit. Following extraction of tooth #11, socket augmentation was done using an autogenous cortico-cancellous block graft and subsequent soft tissue augmentation was done with palatal connective tissue graft. At the end of six months, a tapered self tapping implant fixture was placed with adequate primary stability and after eight weeks, second stage implant surgery was done with the Misch technique in order to recreate papillae and the implant was prosthetically restored. The alveolar ridge was adequately recontoured following the staged surgical protocol. The implant was well integrated at the end of 15 months. Execution of sequential surgical procedures in a highly deficient edentulous site made it possible to achieve of optimal pink and white aesthetics with stable implant supported fixed prosthesis.

  7. Motions in Nearby Galaxy Cluster Reveal Presence of Hidden Superstructure

    2004-09-01

    A nearby galaxy cluster is facing an intergalactic headwind as it is pulled by an underlying superstructure of dark matter, according to new evidence from NASA's Chandra X-ray Observatory. Astronomers think that most of the matter in the universe is concentrated in long large filaments of dark matter and that galaxy clusters are formed where these filaments intersect. A Chandra survey of the Fornax galaxy cluster revealed a vast, swept-back cloud of hot gas near the center of the cluster. This geometry indicates that the hot gas cloud, which is several hundred thousand light years in length, is moving rapidly through a larger, less dense cloud of gas. The motion of the core gas cloud, together with optical observations of a group of galaxies racing inward on a collision course with it, suggests that an unseen, large structure is collapsing and drawing everything toward a common center of gravity. X-ray Image of Fornax with labels X-ray Image of Fornax with labels "At a relatively nearby distance of about 60 million light years, the Fornax cluster represents a crucial laboratory for studying the interplay of galaxies, hot gas and dark matter as the cluster evolves." said Caleb Scharf of Columbia University in New York, NY, lead author of a paper describing the Chandra survey that was presented at an American Astronomical Society meeting in New Orleans, LA. "What we are seeing could be associated directly with the intergalactic gas surrounding a very large scale structure that stretches over millions of light years." The infalling galaxy group, whose motion was detected by Michael Drinkwater of the University of Melbourne in Australia, and colleagues, is about 3 million light years from the cluster core, so a collision with the core will not occur for a few billion years. Insight as to how this collision will look is provided by the elliptical galaxy NGC 1404 that is plunging into the core of the cluster for the first time. As discussed by Scharf and another group

  8. Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

    Ghanbarzadeh, Jalil; Dashti, Hossin; Karamad, Reza; Alikhasi, Marzieh; Nakhaei, Mohammadreza

    2015-01-01

    The final position of the abutment changes with the amount of tightening torque. This could eventually lead to loss of passivity and marginal misfit of prostheses. The aim of this study was to evaluate the effect of three different tightening torques on the marginal adaptation of 3-unit cement-retained implant-supported fixed dental prostheses (FDPs). Two implants (Straumann) were inserted in an acrylic block so that one of the implants was placed vertically and the other at a 15° vertical angle. A straight abutment and a 15° angulated abutment were connected to the vertically and obliquely installed implants, respectively, so that the two abutments were parallel. Then, 10 cement-retained FDPs were waxed and cast. Abutments were tightened with 10, 20, and 35 Ncm torques, respectively. Following each tightening torque, FDPs were luted on respective abutments with temporary cement. The marginal adaptation of the retainers was evaluated using stereomicroscope. FDPs were then removed from the abutments and were sectioned at the connector sites. The retainers were luted again on their respective abutments. Luting procedures and marginal adaptation measurement were repeated. Data were analyzed by ANOVA and least significant difference tests (α = 0.05). After cutting the FDP connectors, the independent samples t-test was used to compare misfit values (α = 0.05). Following 10, 20, and 35 Ncm tightening torques, the marginal discrepancy of the retainers of FDPs significantly increased (P marginal discrepancies of these two retainers (P > 0.05). The marginal gap values of angulated abutment retainers (ANRs) were significantly higher than those of the straight abutment after cutting the connectors (P = 0.026). Within the limitations of this study, the marginal misfit of cement-retained FDPs increased continuously when the tightening torque increased. After cutting the connectors, the marginal misfit of the ANRs was higher than those of the straight abutment retainers.

  9. Photoelastic analysis of mandibular full-arch implant-supported fixed dentures made with different bar materials and manufacturing techniques.

    Zaparolli, Danilo; Peixoto, Raniel Fernandes; Pupim, Denise; Macedo, Ana Paula; Toniollo, Marcelo Bighetti; Mattos, Maria da Glória Chiarello de

    2017-12-01

    To compare the stress distribution of mandibular full dentures supported with implants according to the bar materials and manufacturing techniques using a qualitative photoelastic analysis. An acrylic master model simulating the mandibular arch was fabricated with four Morse taper implant analogs of 4.5×6mm. Four different bars were manufactured according to different material and techniques: fiber-reinforced resin (G1, Trinia, CAD/CAM), commercially pure titanium (G2, cpTi, CAD/CAM), cobalt‑chromium (G3, Co-Cr, CAD/CAM) and cobalt‑chromium (G4, Co-Cr, conventional cast). Standard clinical and laboratory procedures were used by an experienced dental technician to fabricate 4 mandibular implant-supported dentures. The photoelastic model was created based on the acrylic master model. A load simulation (150N) was performed in total occlusion against the antagonist. Dentures with fiber-reinforced resin bar (G1) exhibited better stress distribution. Dentures with machined Co-Cr bar (G3) exhibited the worst standard of stress distribution, with an overload on the distal part of the posteriors implants, followed by dentures with cast Co-Cr bar (G4) and machined cpTi bar (G2). The fiber-reinforced resin bar exhibited an adequate stress distribution and can serve as a viable alternative for oral rehabilitation with mandibular full dentures supported with implants. Moreover, the use of the G1 group offered advantages including reduced weight and less possible overload to the implants components, leading to the preservation of the support structure. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques

    Baldassarri, Marta; Zhang, Yu; Thompson, Van P.; Rekow, Elizabeth D.; Stappert, Christian F. J.

    2011-01-01

    Summary Objectives To compare fatigue failure modes and reliability of hand-veneered and over-pressed implant-supported three-unit zirconium-oxide fixed-dental-prostheses(FDPs). Methods Sixty-four custom-made zirconium-oxide abutments (n=32/group) and thirty-two zirconium-oxide FDP-frameworks were CAD/CAM manufactured. Frameworks were veneered with hand-built up or over-pressed porcelain (n=16/group). Step-stress-accelerated-life-testing (SSALT) was performed in water applying a distributed contact load at the buccal cusp-pontic-area. Post failure examinations were carried out using optical (polarized-reflected-light) and scanning electron microscopy (SEM) to visualize crack propagation and failure modes. Reliability was compared using cumulative-damage step-stress analysis (Alta-7-Pro, Reliasoft). Results Crack propagation was observed in the veneering porcelain during fatigue. The majority of zirconium-oxide FDPs demonstrated porcelain chipping as the dominant failure mode. Nevertheless, fracture of the zirconium-oxide frameworks was also observed. Over-pressed FDPs failed earlier at a mean failure load of 696 ± 149 N relative to hand-veneered at 882 ± 61 N (profile I). Weibull-stress-number of cycles-unreliability-curves were generated. The reliability (2-sided at 90% confidence bounds) for a 400N load at 100K cycles indicated values of 0.84 (0.98-0.24) for the hand-veneered FDPs and 0.50 (0.82-0.09) for their over-pressed counterparts. Conclusions Both zirconium-oxide FDP systems were resistant under accelerated-life-time-testing. Over-pressed specimens were more susceptible to fatigue loading with earlier veneer chipping. PMID:21557985

  11. Comparison of Treatment Outcomes in Partially Edentulous Patients with Implant-Supported Fixed Prostheses and Removable Partial Dentures.

    Nogawa, Toshifumi; Takayama, Yoshiyuki; Ishida, Keita; Yokoyama, Atsuro

    The aim of this study was to compare masticatory performance, occlusal force, and oral health-related quality of life (OHRQoL) in patients with mandibular distal-extension edentulism between those with implant-supported fixed prostheses (ISFPs) and those with removable partial dentures (RPDs), and to evaluate relationships among them. Subjects were recruited from patients using ISFPs or RPDs for mandibular distal-extension edentulism. Masticatory performance was evaluated based on the glucose extracted from chewed gummy jelly. Occlusal force was measured with a pressure-sensitive sheet, and data were subjected to computer analysis. The Japanese version of the Oral Health Impact Profile (OHIP-J) was used to evaluate OHRQoL. The masticatory performance, occlusal force, and OHIP-J scores of the ISFP and RPD groups were compared using the Wilcoxon rank-sum test. The relationships among the variables were analyzed using the Spearman rank correlation coefficient test. Multivariate logistic regression analysis was employed with the OHIP-J score as a dependent variable. Nineteen patients with ISFPs and 25 patients with RPDs participated in this study. No significant difference was observed between the two groups with regard to masticatory performance and occlusal force. The OHIP-J score was significantly lower in the ISFP group than in the RPD group. The OHIP-J score had no significant correlation with masticatory performance, but was significantly correlated with occlusal force and the prosthetic method. Multivariate logistic regression analysis showed that younger age, RPDs, and lower occlusal force were significantly associated with a higher OHIP-J summary score. The present results suggest that the difference in masticatory performance and occlusal force between ISFPs and RPDs is small, but ISFPs are superior to RPDs with regard to OHRQoL in patients with mandibular distal-extension edentulism. In addition, there appears to be a slight correlation between the OHIP

  12. Analysis of load distribution in tooth-implant supported fixed partial dentures by the use of resilient abutment.

    Glisić, Mirko; Stamenković, Dragoslav; Grbović, Aleksandar; Todorović, Aleksandar; Marković, Aleksa; Trifković, Branka

    2016-01-01

    Differences between the tooth and implant response to load can lead to many biological and technical implications in the conditions of occlusal forces. The objective of this study was to analyze load distribution in tooth/implant-supported fixed partial dentures with the use of resilient TSA (Titan Shock Absorber, BoneCare GmbH, Augsburg, Germany) abutment and conventional non-resilient abutment using finite element method. This study presents two basic 3D models. For one model a standard non-resilient abutment is used, and on the implant of the second model a resilient TSA abutment is applied. The virtual model contains drawn contours of tooth, mucous membranes, implant, cortical bones and spongiosa, abutment and suprastructure. The experiment used 500 N of vertical force, applied in three different cases of axial load. Calculations of von Mises equivalent stresses of the tooth root and periodontium, implants and peri-implant tissue were made. For the model to which a non-resilient abutment is applied, maximum stress values in all three cases are observed in the cortical part of the bone (maximum stress value of 49.7 MPa). Measurements of stress and deformation in the bone tissue in the model with application of the resilientTSA abutment demonstrated similar distribution; however, these values are many times lower than in the model with non-resilient TSA abutment (maximum stress value of 28.9 MPa). Application of the resilient TSA abutment results in more equal distribution of stress and deformations in the bone tissue under vertical forces. These values are many times lower than in the model with the non-resilient abutment.

  13. A study of the bending resistance of implant-supported reinforced alumina and machined zirconia abutments and copies.

    Sundh, Anders; Sjögren, Göran

    2008-05-01

    The purpose of the present study was to evaluate the bending resistance of implant-supported CAD/CAM-processed restorations made out of zirconia or manually shaped made out of reinforced alumina. Units of abutments and copies made of (i) a prefabricated hot isostatic pressed (HIPed) yttrium oxide partially-stabilized zirconia (Y-TZP) (Denzir), (ii) a prefabricated densely-sintered magnesia partially stabilized zirconia (Mg-PSZ) (Denzir-M) or, copies made of (iii) a prefabricated partially-sintered, porous reinforced alumina ceramic (RN synOcta-In-Ceram) were subjected to static loading perpendicularly at the long axis. The abutments were attached to either stainless steel analogs or titanium implant fixtures. The Y-TZP and Mg-PSZ copies were bonded onto the ceramic abutments with a dual-cured resin composite (Rely-X Unicem). Units of titanium abutment attached to a titanium implant fixtures were used as reference. The units comprising Denzir abutments as delivered (pstainless steel analogs exhibited significantly higher bending resistance than the control. The heat-treated Denzir copies bonded to the heat-treated Denzir M abutments attached to titanium implant fixtures and the In-Ceram specimens attached to stainless steel analogs showed significantly (pstainless steel analogs. No statistically significant (p>0.05) differences were seen among the other groups studied. All the ceramic abutments and copies exhibited values that were equal or superior to that of the control and exceeded the reported value, up to 300 N, for maximum incisal bite forces. To assess the clinical behavior long-term clinical studies should be conducted.

  14. Biomechanical comparison of two different collar structured implants supporting 3-unit fixed partial denture: a 3-D FEM study.

    Meriç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; Ozden, Ahmet Utku

    2012-01-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.

  15. Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: a crossover clinical trial.

    Krennmair, Gerald; Seemann, Rudolf; Fazekas, Andres; Ewers, Rolf; Piehslinger, Eva

    2012-01-01

    To determine patient satisfaction and preference for implant-supported mandibular overdentures (IOD) retained with ball or Locator attachments. In addition, peri-implant conditions and prosthodontic maintenance efforts for the final attachments were evaluated after 1 year of function. In this crossover clinical trial, 20 edentulous patients were recruited to receive two mandibular implants in the canine region and were provided with implant-retained mandibular overdentures and new complete maxillary dentures. Implant-retained mandibular overdentures were stabilized with either ball attachments or Locator attachments, in random order. After 3 months of function, the attachments in the existing denture were changed. Questionnaires on satisfaction/complaints with the prostheses were administered at baseline (with the old dentures) and after 3 months of function with each attachment, thus providing for an intraindividual comparison. The decision for the final attachment chosen was based on the patient's preference. For the definitive attachment, peri-implant conditions (peri-implant marginal bone resorption, pocket depth, and Plaque Index, Gingival Index, and Bleeding Index) as well as prosthodontic maintenance efforts and satisfaction score were evaluated after an insertion period of 1 year. Nineteen (95%) patients completed the study (1 dropout). Patient satisfaction improved significantly (P<.05) from baseline (old dentures) to the new prostheses retained with each of the two attachment types for all domains of satisfaction. However, there were no differences between ball or Locator attachment for any items of satisfaction evaluated and neither attachment had a significant patient preference. No differences for peri-implant parameters or for patient satisfaction were noted between the definitive attachments (ball, n=10; Locator, n=9) after 1 year. Although the overall incidence rate of prosthodontic maintenance did not significantly differ between both retention

  16. Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

    Alfadda, Sara A; Al Amri, Mohammad D; Al-Ohali, Amal; Al-Hakami, Arwa; Al-Madhi, Noura

    To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r = 0.389 and r = 0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the maxillary conventional denture. IID had no effect on the clinical quality of either denture and did not influence patient satisfaction.

  17. Effect of geometry on deformation of anterior implant-supported zirconia frameworks: An in vitro study using digital image correlation.

    Calha, Nuno; Messias, Ana; Guerra, Fernando; Martinho, Beatriz; Neto, Maria Augusta; Nicolau, Pedro

    2017-04-01

    To evaluate the effect of geometry on the displacement and the strain distribution of anterior implant-supported zirconia frameworks under static load using the 3D digital image correlation method. Two groups (n=5) of 4-unit zirconia frameworks were produced by CAD/CAM for the implant-abutment assembly. Group 1 comprised five straight configuration frameworks and group 2 consisted of five curved configuration frameworks. Specimens were cemented and submitted to static load up to 200N. Displacements were captured with two high-speed photographic cameras and analyzed with video correlation system in three spacial axes U, V, W. Statistical analysis was made using the nonparametric Mann-Whitney test. Up to 150N loads, the vertical displacements (V axis) were statistically higher for curved frameworks (-267.83±23.76μm), when compared to the straight frameworks (-120.73±36.17μm) (p=0.008), as well as anterior displacements in the W transformed axis (589.55±64.51μm vs 224.29±50.38μm for the curved and straight frameworks), respectively (p=0.008). The mean von Mises strains over the surface frameworks were statistically higher for the curved frameworks under any load. Within the limitations of this in vitro study, it is possible to conclude that the geometric configuration influences the deformation of 4-unit anterior frameworks under static load. The higher strain distribution and micro-movements of the curved frameworks reflect less rigidity and increased risk of fractures associated to FPDs. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  18. High-resolution electron microscopy on incommensurate long-period superstructures of hexagonal-close-packed Cu-Sb alloy

    Onozuka, T.; Kakehashi, S.; Takahashi, T.; Hirabayashi, M.

    1989-01-01

    Hexagonal incommensurate long-period superstructures of the Cu-Sb alloys containing 18-20 at.% Sb have been investigated by means of superstructure imaging using a high-resolution electron microscope. Honeycomb-type distributions of hexagonal domains consisting of the commensurate superstructure of type 7a 0 -2H are observed. The incommensurabilities of superstructure can be interpreted well with a hexagonal model composed of the 7a 0 -2H domains surrounded by domain walls which contain higher Sb content than the domain interior. The observed image contrast is reproduced well with multislice computer simulations based on the structure models proposed for the 7a 0 -2H domain and the domain wall. (orig.)

  19. High-resolution electron microscopy on incommensurate long-period superstructures of hexagonal-close-packed Cu-Sb alloy

    Onozuka, T.; Kakehashi, S.; Takahashi, T.; Hirabayashi, M. (Tohoku Univ., Sendai (Japan). Inst. for Materials Research)

    1989-06-01

    Hexagonal incommensurate long-period superstructures of the Cu-Sb alloys containing 18-20 at.% Sb have been investigated by means of superstructure imaging using a high-resolution electron microscope. Honeycomb-type distributions of hexagonal domains consisting of the commensurate superstructure of type 7a{sub 0}-2H are observed. The incommensurabilities of superstructure can be interpreted well with a hexagonal model composed of the 7a{sub 0}-2H domains surrounded by domain walls which contain higher Sb content than the domain interior. The observed image contrast is reproduced well with multislice computer simulations based on the structure models proposed for the 7a{sub 0}-2H domain and the domain wall. (orig.).

  20. Three-dimensional esthetic analysis in treatment planning for implant-supported fixed prosthesis in the edentulous maxilla: review of the esthetics literature.

    Bidra, Avinash S

    2011-08-01

    Fixed implant-supported prosthesis for the edentulous maxilla has gained tremendous popularity over the years. Multiple prosthetic designs have been introduced in order to accommodate a gamut of clinical situations. Irrespective of the design, it is paramount that the esthetics imparted by the prosthesis be uncompromised. Though esthetics is subjective, a common ground exists where all its fundamental principles converge. This article reviews pertinent dental and facial esthetics literature for application of various esthetic concepts involved in diagnosis and treatment planning for an implant-supported fixed prosthesis in the edentulous maxilla. Three-dimensional esthetic analysis involves assessment of various esthetic parameters in superior-inferior, medial-lateral, and anterior-posterior dimensions. The impact of various esthetic parameters such as facial forms, facial profiles, maxillary teeth positions, maxillary teeth proportions, smile lines, lip support, gingival display, facial midline, dental midline, horizontal cant, and smile width are discussed in detail. © 2011 Wiley Periodicals, Inc.

  1. Fabrication of a Customized Ball Abutment to Correct a Nonparallel Implant Abutment for a Mandibular Implant-Supported Removable Partial Prosthesis: A Case Report

    Hossein Dasht

    2017-12-01

    Full Text Available Introduction: While using an implant-supported removable partial prosthesis, the implant abutments should be parallel to one another along the path of insertion. If the implants and their attachments are placed vertically on a similar occlusal plane, not only is the retention improved, the prosthesis will also be maintained for a longer period. Case Report: A 65-year-old male patient referred to the School of Dentistry in Mashhad, Iran with complaints of discomfort with the removable partial dentures for his lower mandible. Due to the lack of parallelism in the supporting implants, prefabricated ball abutment could not be used. As a result, a customized ball abutment was fabricated in order to correct the non-parallelism of the implants. Conclusion: Using UCLA abutments could be a cost-efficient approach for the correction of misaligned implant abutments in implant-supported overdentures.

  2. [Systematic review and meta-analysis on the effect of implant supported overdentures on the oral health related quality of life of edentulous patients].

    Zhang, S S; Zhang, Y; Di, P; Lin, Y

    2017-05-09

    Objective: To evaluate the effect of implant related treatment on the oral health related quality of life (OHRQoL) of edentulous patients. Methods: The CNKI, Wanfang database and Medline, EMBASE, Cochrane Library databases that include randomized clinical trials comparing implant supported overdentures with conventional complete denture for edentulous patients were retrived. Nine studies involving 769 cases were included and meta-analysis was conducted. Results: The standardized mean difference (SMD) of oral health impact profile (OHIP) score was 1.63 (95% CI: 1.25-2.02) and improved after implant related treatment, which was significantly better than the conventional complete denture (0.87, 95% CI: 0.54-1.20). Conclusions: Implant supported overdentures improved patient's OHRQoL and showed better performance compared to the overdentures complete dentures.

  3. DEPENDENCIES TO DETERMINE THE MEASURE OF DAMAGE AND CALCULATION OF RESIDUAL LIFE OF REINFORCED CONCRETE SUPERSTRUCTURE, EXPOSED TO SALT CORROSION

    SAATOVA NODIRA ZIYAYEVNA

    2016-01-01

    In this paper we consider the current method of determining the measure of damage of concrete and reinforcement. The proposed dependence measures of damage, convenient for use in predicting the life of structures superstructures.The practical method of calculation determination of residual resource of the exploited superstructures developed. The main source of data for calculating the residual life are the parameters defined by the technical diagnosis.

  4. Optimal processing pathway for the production of biodiesel from microalgal biomass: A superstructure based approach

    Rizwan, Muhammad; Lee, Jay H.; Gani, Rafiqul

    2013-01-01

    In this study, we propose a mixed integer nonlinear programming (MINLP) model for superstructure based optimization of biodiesel production from microalgal biomass. The proposed superstructure includes a number of major processing steps for the production of biodiesel from microalgal biomass......, such as the harvesting of microalgal biomass, pretreatments including drying and cell disruption of harvested biomass, lipid extraction, transesterification, and post-transesterfication purification. The proposed model is used to find the optimal processing pathway among the large number of potential pathways that exist...... for the production of biodiesel from microalgae. The proposed methodology is tested by implementing on a specific case with different choices of objective functions. The MINLP model is implemented and solved in GAMS using a database built in Excel. The results from the optimization are analyzed...

  5. Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study.

    Gonçalves, Fernanda de Cássia Papaiz; Amaral, Marina; Borges, Alexandre Luiz Souto; Gonçalves, Luiz Fernando Martins; Paes-Junior, Tarcisio José de Arruda

    2018-04-01

    Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (α=.05). The mean maximum load ±standard deviation for the molar group was 393.4 ±95.0 N with reinforcement and 305.4 ±76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 ±283.7 N with reinforcement and 605.3 ±90.5 N without reinforcement (P=.001). Reinforcement with nylon mesh increased the mean maximum load of implant-supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Fabrication of a Customized Ball Abutment to Correct a Nonparallel Implant Abutment for a Mandibular Implant-Supported Removable Partial Prosthesis: A Case Report

    Hossein Dasht; Mohammadreza Nakhaei; Nafiseh teimouri

    2017-01-01

    Introduction: While using an implant-supported removable partial prosthesis, the implant abutments should be parallel to one another along the path of insertion. If the implants and their attachments are placed vertically on a similar occlusal plane, not only is the retention improved, the prosthesis will also be maintained for a longer period. Case Report: A 65-year-old male patient referred to the School of Dentistry in Mashhad, Iran with complaints of discomfort with the removable partial ...

  7. Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study

    Hadi Mokhtarpour

    2016-07-01

    Full Text Available Background. Fracture load of implant-supported restorations is an important factor in clinical success. This study evaluated the effect of two techniques for screw access hole preparation on the fracture load of cement-screw-retained implant-supported zirconia-based crowns. Methods. Thirty similar cement-screw-retained implant-supported zirconia-based maxillary central incisor crowns were evaluated in three groups of 10. Group NH: with no screw access holes for the control; Group HBS: with screw access holes prepared with a machine before zirconia sintering; Group HAS: with screw access holes prepared manually after zirconia sintering. In group HBS, the access holes were virtually designed and prepared by a computer-assisted design/computer-assisted manufacturing system. In group HAS, the access holes were manually prepared after zirconia sintering using a diamond bur. The dimensions of the screw access holes were equal in both groups. The crowns were cemented onto same-size abutments and were then subjected to thermocycling. The fracture load values of the crowns were measured using a universal testing machine. Data were analyzed with ANOVA and Tukey test (P < 0.05. Results. The mean fracture load value for the group NH was 888.37 ± 228.92 N, which was the highest among the groups, with a significant difference (P < 0.0001. The fracture load values were 610.48 ± 125.02 N and 496.74 ± 104.10 Nin the HBS and HAS groups, respectively, with no significant differences (P = 0.44. Conclusion. Both techniques used for preparation of screw access holes in implant-supported zirconia-based crowns de-creased the fracture load.

  8. Implant-Supported PMMA Monolithic Full-Arch Rehabilitation with Surgical Computer-Planned Guide and Immediate Provisional: A Case Report with One Year Follow-Up

    Vincenzo Luca Zizzari

    2018-01-01

    Full Text Available The aim of this case report is to describe the surgical and prosthetic procedures to achieve maxillary and mandibular implant-supported PMMA monolithic full-arch rehabilitation (PMFR with surgical computer-planned guide and immediate provisional. In such cases, the correct planning of dental implants’ position, length, and diameter and the prosthetic phases via computer-aided design are very important to achieve good aesthetic and functional long-lasting results.

  9. Implant-Supported PMMA Monolithic Full-Arch Rehabilitation with Surgical Computer-Planned Guide and Immediate Provisional: A Case Report with One Year Follow-Up

    Zizzari, Vincenzo Luca; Tacconelli, Gianmarco

    2018-01-01

    The aim of this case report is to describe the surgical and prosthetic procedures to achieve maxillary and mandibular implant-supported PMMA monolithic full-arch rehabilitation (PMFR) with surgical computer-planned guide and immediate provisional. In such cases, the correct planning of dental implants’ position, length, and diameter and the prosthetic phases via computer-aided design are very important to achieve good aesthetic and functional long-lasting results.

  10. Enigmatic cranial superstructures among Chamorro ancestors from the Mariana Islands: gross anatomy and microanatomy.

    Heathcote, Gary M; Bromage, Timothy G; Sava, Vincent J; Hanson, Douglas B; Anderson, Bruce E

    2014-06-01

    This study focuses on the gross anatomy, anatomic relations, microanatomy, and the meaning of three enigmatic, geographically patterned, and quasi-continuous superstructures of the posterior cranium. Collectively known as occipital superstructures (OSSs), these traits are the occipital torus tubercle (TOT), retromastoid process (PR), and posterior supramastoid tubercle (TSP). When present, TOT, PR, and TSP develop at posterior cranial attachment sites of the upper trapezius, superior oblique, and sternocleidomastoid muscles, respectively. Marked expression and co-occurrence of these OSSs are virtually circumscribed within Oceania and reach highest recorded frequencies in protohistoric Chamorros (CHamoru) of the Mariana Islands. Prior to undertaking scanning electron microscopy (SEM) work, our working multifactorial model for OSS development was that early-onset, long-term, and chronic activity-related microtrauma at enthesis sites led to exuberant reactive or reparative responses in a substantial minority of genetically predisposed (and mostly male) individuals. SEM imaging, however, reveals topographic patterning that questions, but does not negate, activity induction of these superstructures. Although OSSs appear macroscopically as relatively large and discrete phenomena, SEM findings reveal a unique, widespread, and seemingly systemic distribution of structures over the occipital surface that have the appearance of OSS microforms. Nevertheless, apparent genetic underpinnings, anatomic relationships with muscle entheses, and positive correlation of OSS development with humeral robusticity continue to suggest that these superstructures have potential to at once bear witness to Chamorro population history and inform osteobiographical constructions of chronic activity patterns in individuals bearing them. Further work is outlined that would illuminate the proximate and ultimate meanings of OSS. Copyright © 2014 Wiley Periodicals, Inc.

  11. Effect of modeling of super-structure on the behaviour of reactor building raft

    Mondal, A.; Singh, A.K.; Roy, Raghupati; Verma, U.S.P.; Warudkar, A.S.

    2003-01-01

    The behaviour of the reactor building raft was studied when the stiffness of the super-structural elements is included in the analysis as compared to the results of conventional analysis ignoring the stiffness of the super-structural elements. The effect of the stiffness of the super-structures on the loss of contact of the raft under seismic environment was also investigated. In order to study the effect of horizontal springs on the behaviour of the raft particularly near the stressing gallery under seismic environment, a separate study has been carried out considering a 3D model consisting of solid elements supported on both horizontal and vertical springs. The model was analysed for all the forces applied at the top of the raft and the analysis results were compared with those of shell model. The following conclusions are drawn: (i) Idealisation of the reactor building raft using shell elements is adequate for estimating the design forces/moments on the raft. The design forces/moments obtained from FE model consisting of solid elements closely matches with those obtained from FE model with shell elements. Idealisation of the RB raft using shell elements will also reduce the problem size and the related computational efforts. (ii) The stiffness of the super-structure has significant effect on the behaviour of the raft. Consideration of the stiffness of the super structure reduces the design forces/moments significantly and hence, modelling of the stiffness of the super structure is necessary for economical design. (iii) Modelling of horizontal stiffness of the raft in terms of horizontal springs at the interface of the raft and the rock does not have significant effect on the behaviour of the raft and as such, is not required to be considered in the FE model. However, it is necessary to ensure adequate factor of safety against the overall stability of the raft

  12. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments.

    Santing, Hendrik Jacob; Meijer, Henny J A; Raghoebar, Gerry M; Özcan, Mutlu

    2012-12-01

    Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. The objectives of this study were to evaluate the fracture strength of implant-supported composite resin crowns on PEEK and solid titanium temporary abutments, and to analyze the failure types. Three types of provisional abutments, RN synOcta Temporary Meso Abutment (PEEK; Straumann), RN synOcta Titanium Post for Temporary Restorations (Straumann), and Temporary Abutment Engaging NobRplRP (Nobel Biocare) were used, and provisional screw-retained crowns using composite resin (Solidex) were fabricated for four different locations in the maxilla. The specimens were tested in a universal testing machine at a crosshead speed of 1 mm/minute until fracture occurred. The failure types were analyzed and further categorized as irreparable (Type 1) or reparable (Type 2). No significant difference was found between different abutment types. Only for the position of the maxillary central incisor, composite resin crowns on PEEK temporary abutments showed significantly lower (p Provisional crowns on PEEK abutments showed similar fracture strength as titanium temporary abutments except for central incisors. Maxillary right central incisor composite resin crowns on PEEK temporary abutments fractured below the mean anterior masticatory loading forces reported to be approximately 206 N. © 2010 Wiley Periodicals, Inc.

  13. Prosthetic outcome, patient complaints, and nutritional effects on elderly patients with magnet-retained, implant-supported overdentures--a 1-year report.

    Khoo, Huan Ding; Chai, John; Chow, Tak Wah

    2013-01-01

    To study the changes in treatment outcomes of complete dentures and magnet-retained, implant-supported overdentures in a group of elderly patients. In this nonrandomized trial, 43 edentulous patients (14 men and 29 women) were fitted with complete dentures followed by implant-supported mandibular overdenture in a sequential model. Treatment outcomes used for analysis included objective assessment of denture quality (Woelfel's index), patient satisfaction, nutritional status, body mass index (BMI), and serum albumin level. The McNemar test was used to determine if significant differences in the Woelfel's index and nutritional status existed at different treatment phases. Repeated measures ANOVA and multiple pairwise comparison tests were used to analyze patient satisfaction. BMI status and serum albumin level at different treatment phases were analyzed with one-way ANOVA and Tukey post hoc test. At the 1-year follow-up, significant improvements were recorded for the objective assessment of denture quality and patient complaints (P .05) CONCLUSIONS: The present study demonstrated that in elderly patients with stable health and nutritional status, complete dentures made in a university clinic brought about overall improvement in denture quality and reduction in denture complaint score. Insertion of mandibular implant-supported overdentures further improved the mandibular denture quality and reduced the mandibular denture complaint score. In this group of patients, no improvement in BMI, serum albumin value, and nutritional status were documented.

  14. A 5- to 8-year retrospective study comparing the clinical results of implant-supported telescopic crown versus bar overdentures in patients with edentulous maxillae.

    Zou, Duohong; Wu, Yiqun; Huang, Wei; Zhang, Zhiyong; Zhang, Zhiyuan

    2013-01-01

    The objective of this study was to compare implant survival and success rates, peri-implant parameters, and prosthodontic maintenance efforts for implant-supported telescopic crown overdentures and bar overdentures to restore maxillary edentulism. This retrospective clinical study involved patients with maxillary edentulism who were fitted with implant-supported overdentures from January 2004 to June 2007. During a 5- to 8-year follow-up period, the implant survival and success rates, biologic and mechanical complications, prosthodontic maintenance, and patient satisfaction were retrospectively analyzed. The data were evaluated statistically and P overdentures. Twenty-one patients chose telescopic crown overdentures and 23 patients chose bar overdentures. A total of 41 patients and 201 implants were available for follow-up. The implant survival and success rates, average bone resorption, and subjective patient satisfaction scores showed no difference between the telescopic crown and the bar overdenture group at follow-up. However, there were higher values for Plaque and Calculus Indexes in the bar group compared with the telescopic crown group, and these values showed a statistically significant difference annually from the 3-year follow-up (P overdentures provided a healthy peri-implant structure for implants in both groups. Implant-supported telescopic crown or bar overdentures can provide a good treatment option for patients with edentulous maxillae.

  15. Automatic recognition of ship types from infrared images using superstructure moment invariants

    Li, Heng; Wang, Xinyu

    2007-11-01

    Automatic object recognition is an active area of interest for military and commercial applications. In this paper, a system addressing autonomous recognition of ship types in infrared images is proposed. Firstly, an approach of segmentation based on detection of salient features of the target with subsequent shadow removing is proposed, as is the base of the subsequent object recognition. Considering the differences between the shapes of various ships mainly lie in their superstructures, we then use superstructure moment functions invariant to translation, rotation and scale differences in input patterns and develop a robust algorithm of obtaining ship superstructure. Subsequently a back-propagation neural network is used as a classifier in the recognition stage and projection images of simulated three-dimensional ship models are used as the training sets. Our recognition model was implemented and experimentally validated using both simulated three-dimensional ship model images and real images derived from video of an AN/AAS-44V Forward Looking Infrared(FLIR) sensor.

  16. Overcoming artificial spatial correlations in simulations of superstructure domain growth with parallel Monte Carlo algorithms

    Schleier, W.; Besold, G.; Heinz, K.

    1992-01-01

    The authors study the applicability of parallelized/vectorized Monte Carlo (MC) algorithms to the simulation of domain growth in two-dimensional lattice gas models undergoing an ordering process after a rapid quench below an order-disorder transition temperature. As examples they consider models with 2 x 1 and c(2 x 2) equilibrium superstructures on the square and rectangular lattices, respectively. They also study the case of phase separation ('1 x 1' islands) on the square lattice. A generalized parallel checkerboard algorithm for Kawasaki dynamics is shown to give rise to artificial spatial correlations in all three models. However, only if superstructure domains evolve do these correlations modify the kinetics by influencing the nucleation process and result in a reduced growth exponent compared to the value from the conventional heat bath algorithm with random single-site updates. In order to overcome these artificial modifications, two MC algorithms with a reduced degree of parallelism ('hybrid' and 'mask' algorithms, respectively) are presented and applied. As the results indicate, these algorithms are suitable for the simulation of superstructure domain growth on parallel/vector computers. 60 refs., 10 figs., 1 tab

  17. The role of prosthetic abutment material on the stress distribution in a maxillary single implant-supported fixed prosthesis

    Peixoto, Hugo Eduardo, E-mail: hugo.e.peixoto@hotmail.com [Implantology Team, Latin American Institute of Research and Education in Dentistry, Curitiba, Paraná (Brazil); Bordin, Dimorvan, E-mail: dimorvan_bordin@hotmail.com [Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Limeira avenue, 901-Vila Rezende, Piracicaba, SP 13414-903 (Brazil); Del Bel Cury, Altair A., E-mail: altcury@fop.unicamp.br [Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Limeira avenue, 901-Vila Rezende, Piracicaba, SP 13414-903 (Brazil); Silva, Wander José da, E-mail: wanderjose@fop.unicamp.br [Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Limeira avenue, 901-Vila Rezende, Piracicaba, SP 13414-903 (Brazil); Faot, Fernanda, E-mail: fernanda.faot@gmail.com [Department of Restorative Dentistry, School of Dentistry, Federal University of Pelotas, Gonçalves Chaves, 457, 2nd floor, Pelotas, Rio Grande do Sul 96015-560 (Brazil)

    2016-08-01

    Purpose: Evaluate the influence of abutment's material and geometry on stress distribution in a single implant-supported prosthesis. Materials and Methods: Three-dimensional models were made based on tomographic slices of the upper middle incisor area, in which a morse taper implant was positioned and a titanium (Ti) or zirconia (ZrN) universal abutments was installed. The commercially available geometry of titanium (T) and zirconia (Z) abutments were used to draw two models, TM1 and ZM1 respectively, which served as control groups. These models were compared with 2 experimental groups were the mechanical properties of Z were applied to the titanium abutment (TM2) and vice versa for the zirconia abutment (ZM2). Subsequently, loading was simulated in two steps, starting with a preload phase, calculated with the respective friction coefficients of each materials, followed by a combined preload and chewing force. The maximum von Mises stress was described. Data were analyzed by two-way ANOVA that considered material composition, geometry and loading (p < 0.05). Results: Titanium and zirconia abutments showed similar von Mises stresses in the mechanical part of the four models. The area with the highest concentration of stress was the screw thread, following by the screw body. The highest stress levels occurred in screw thread was observed during the preloading phase in the ZM1 model (931 MPa); and during the combined loading in the TM1 model (965 MPa). Statistically significant differences were observed for loading, the material × loading interaction, and the loading × geometry interaction (p < 0.05). Preloading contributed for 77.89% of the stress (p < 0.05). There were no statistically significant differences to the other factors (p > 0.05). Conclusion: The screw was the piece most intensely affected, mainly through the preload force, independent of the abutment's material. - Highlights: • The abutment's screw was the most impaired piece of the

  18. An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

    Fatalla, Abdalbseet A; Song, Ke; Du, Tianfeng; Cao, Yingguang

    2012-02-01

    and 2880 insertion and removal cycles. During the tensile test a cross-head speed of 10 mm/min was applied. Values of absolute force (AF) and relative force (RF) were statistically analyzed by two-way ANOVA and multiple comparison Tukey's tests between groups and cycles periods. The results of fatigue tests showed a 50% reduction in retention force in the subgroups with flexible attachments. A triangular design of overdenture support foundations with O-Ring attachments revealed the lowest value of AF and a relatively high reduction in RF. The four overdenture support designs with flexible acrylic attachments improved the retention force and reduced the fatigue retention. Furthermore, the results of the investigation demonstrate that flexible acrylic attachments for both teeth and implant-supported overdentures offer a wide range of retention forces.

  19. Morphology-controlled hydrothermal synthesis of MnCO3 hierarchical superstructures with Schiff base as stabilizer

    Hu, He; Xu, Jie-yan; Yang, Hong; Liang, Jie; Yang, Shiping; Wu, Huixia

    2011-01-01

    Graphical abstract: MnCO3 microcrystals with hierarchical superstructures were synthesized by using the CO2 in atmosphere as carbonate ions source and Schiff base as shape guiding-agent in water/ethanol system under hydrothermal condition. Highlights: → The most interesting in this work is the use of the greenhouse gases CO 2 in atmosphere as carbonate ions source to precipitate with Mn 2+ for producing MnCO 3 crystals. → This work is the first report related to the small organic molecule Schiff base as shape guiding-agent to produce different MnCO 3 hierarchical superstructures. → We are controllable synthesis of the MnCO 3 hierarchical superstructures such as chrysanthemum, straw-bundle, dumbbell and sphere-like microcrystals. → The as-prepared MnCO 3 could be used precursor to fabricate the Mn 2 O 3 hierarchical superstructures after thermal decomposition at high temperature. -- Abstract: MnCO 3 with hierarchical superstructures such as chrysanthemum, straw-bundle, dumbbell and sphere-like were synthesized in water/ethanol system under environment-friendly hydrothermal condition. In the synthesis process, the CO 2 in atmosphere was used as the source of carbonate ions and Schiff base was used as shape guiding-agent. The different superstructures of MnCO 3 could be obtained by controlling the hydrothermal temperature, the molar ratio of manganous ions to the Schiff base, or the volume ratio of water to ethanol. A tentative growth mechanism for the generation of MnCO 3 superstructures was proposed based on the rod-dumbbell-sphere model. Furthermore, the MnCO 3 as precursor could be further successfully transferred to Mn 2 O 3 microstructure after heating in the atmosphere at 500 o C, and the morphology of the Mn 2 O 3 was directly determined by that of the MnCO 3 precursor.

  20. Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year

    GARGARI, M.; PRETE, V.; PUJIA, M.; CERUSO, F. M.

    2013-01-01

    Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year.

  1. The influence of professional competence on the inter- and intra-individual esthetic evaluation of implant-supported crowns in the anterior maxilla.

    Petsos, Hari; Trimpou, Georgia; Eickholz, Peter; Lauer, Hans-Christoph; Weigl, Paul

    2017-04-01

    Evaluation of the influence of professional competence on esthetic predictability of implant-supported crowns in the anterior maxilla and identification of objective factors allowing predictable planning for esthetic results. Sixty patients with 82 implants in the esthetic zone were included in this study. Width of keratinized mucosa, biotype, recessions, and papilla index according to Jemt as well as radiological bone loss were assessed. Study casts and photographs were obtained. Each patient as well as people with different level of expertise (laypersons, students and dentists) rated the esthetic satisfaction after final restoration on a scale (1-10). Correlations between esthetic assessments and previously documented clinical parameters were tested. The study failed to show a significant relationship between the raters' level of dental expertise and their subjective esthetic evaluation. However, patients rated themselves much more favorable than the three evaluator groups did. A comparison of the clinical parameters with the esthetic evaluation revealed significantly more favorable ratings by the lay group in the presence of a wide attached gingiva (P = 0.021) than by the other groups and by the laypersons (P = 0.002), the dentists (P = 0.003), and students (P = 0.009) in the absence of recessions. The ratio of the implant crown length to the length of the contralateral crown had a negative effect on ratings for all three groups ([laypersons P esthetic predictability of implant-supported crowns in the anterior maxilla in laypersons' ratings. Furthermore, there is an association between the discrepancy of lengths of implant-supported single crowns to their contralateral natural teeth and esthetic satisfaction for all expertise levels. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. A retrospective 3- to 5-year study of the reconstruction of oral function using implant-supported prostheses in patients with hypohidrotic ectodermal dysplasia.

    Zou, Duohong; Wu, Yiqun; Wang, Xu Dong; Huang, Wei; Zhang, Zhiyong; Zhang, Zhiyuan

    2014-10-01

    The aim of this study was to evaluate oral function rehabilitation in patients with hypohidrotic ectodermal dysplasia (HED) using implant-supported prostheses based on bone augmentation. From September 2005 and March 2009, 25 HED patients were chosen for clinical data analysis in this study. The criteria for patient selection included the following: the display of clinical features of HED, the number of congenitally missing teeth (>5), the patient age (>16 years), the patient's willingness, and the patient's tolerance for bone graft surgery and implant placement. Follow-up evaluations were initiated from the time of implant prosthetic placement and scheduled annually for 3-5 years. The effects of oral function reconstruction were assessed based on the cumulative survival and success rates of implants, the health of the peri-implant area, and the degree of patient satisfaction. Twenty-five HED patients received 169 conventional implants and 10 zygomatic implants (179 total implants). During 3-5 years of post-loading evaluations, 5 of the 179 implants failed and 3 implants were removed. The 3-year success and cumulative survival rates were 97.2% and 98.3%, respectively. Furthermore, periodontal probing and radiographic assessments showed that the 3-year incidence of peri-implantitis was 4.5%. Finally, HED patients expressed high degrees of satisfaction with their facial contours, masticatory function, pronunciation ability, and comfort with the implant-supported prostheses. The results of this 3- to 5-year retrospective study indicate that the oral function of HED patients can be effectively reconstructed using bone augmentation and implant-supported prostheses; however, longer term results are warranted in the future.

  3. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: Retrospective study of a cohort of edentulous patients.

    Fernandez-Estevan, Lucia; Selva-Otaolaurruchi, Eduardo J; Montero, Javier; Sola-Ruiz, Fernanda

    2015-07-01

    This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures). This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire. Individual protocols were created that included socio-demographic data, the Oral Health Impact Profile-20 (OHIP-20) questionnaire and Oral Satisfaction Scale (OSS). Descriptive and bivariate statistical analysis was carried out applying χ², Pearson, Kruskal-Wallis, and Student t tests, transferring data into SPSS-Windows® software from a Microsoft® Excel spreadsheet. The OHIP-20 proved to be a valid instrument and provided reliable assessment of health-related quality of life among both the Spanish general population and edentulous patients. The control and study groups proved comparable, showing socio-demographic homogeneity. For patients with overdentures retained by means of the Locator® system, these restorations had significantly lower impact on quality of life (19 vs 33), both generally and for each individual questionnaire item, and much higher satisfaction with the state of their oral cavities (8.3 vs 5.3) than patients wearing dentures; both sets of data showed a direct linear relationship, so that as the level of impact on quality of life increased, perceived oral satisfaction worsened. Patients rehabilitated with implant supported overdentures retained by the Locator® system, presented significantly lower levels of impact on their quality of life and significantly higher oral satisfaction than patients with conventional complete prostheses.

  4. Comparative analysis of different joining techniques to improve the passive fit of cobalt-chromium superstructures.

    Barbi, Francisco C L; Camarini, Edevaldo T; Silva, Rafael S; Endo, Eliana H; Pereira, Jefferson R

    2012-12-01

    The influence of different joining techniques on passive fit at the interface structure/abutment of cobalt-chromium (Co-Cr) superstructures has not yet been clearly established. The purpose of this study was to compare 3 different techniques of joining Co-Cr superstructures by measuring the resulting marginal misfit in a simulated prosthetic assembly. A specially designed metal model was used for casting, sectioning, joining, and measuring marginal misfit. Forty-five cast bar-type superstructures were fabricated in a Co-Cr alloy and randomly assigned by drawing lots to 3 groups (n=15) according to the joining method used: conventional gas-torch brazing (G-TB), laser welding (LW), and tungsten inert gas welding (TIG). Joined specimens were assembled onto abutment analogs in the metal model with the 1-screw method. The resulting marginal misfit was measured with scanning electron microscopy (SEM) at 3 different points: distal (D), central (C), and mesial (M) along the buccal aspect of both abutments: A (tightened) and B (without screw). The Levene test was used to evaluate variance homogeneity and then the Welsch ANOVA for heteroscedastic data (α=.05). Significant differences were found on abutment A between groups G-TB and LW (P=.013) measured mesially and between groups G-TB and TIG (P=.037) measured centrally. On abutment B, significant differences were found between groups G-TB and LW (Plaser method. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  5. Influence of implant position on clinical crown length and peri-implant soft tissue dimensions at implant-supported single crowns replacing maxillary central incisors

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2013-01-01

    The aims of the present study were to evaluate the influence of implant position on clinical crown length and marginal soft tissue dimensions at implant-supported single crowns of maxillary central incisors, and to validate the papilla index score (PIS). Twenty-five patients, who had lost one of ...... abutments and did not necessarily result in an increased crown length. The distal implant papilla heightwas obviously shorter, althoughthe mesial papilla height was similar to thatof the healthy dentition.The papilla index score was tested to be a valid index for papilla fill....

  6. Prosthetically guided bone sculpturing for a maxillary complete-arch implant-supported monolithic zirconia fixed prosthesis based on a digital smile design: A clinical report.

    Rojas-Vizcaya, Fernando

    2017-11-01

    A digital smile design was used to create an average smile and to develop a removable interim restoration for an edentulous patient with a high smile line and different bone levels in the maxilla. The interim restoration was used as a guide to perform bone sculpturing to create space for the biological width and to restore a monolithic zirconia implant-supported fixed restoration. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. System design optimization for stand-alone photovoltaic systems sizing by using superstructure model

    Azau, M A M; Jaafar, S; Samsudin, K

    2013-01-01

    Although the photovoltaic (PV) systems have been increasingly installed as an alternative and renewable green power generation, the initial set up cost, maintenance cost and equipment mismatch are some of the key issues that slows down the installation in small household. This paper presents the design optimization of stand-alone photovoltaic systems using superstructure model where all possible types of technology of the equipment are captured and life cycle cost analysis is formulated as a mixed integer programming (MIP). A model for investment planning of power generation and long-term decision model are developed in order to help the system engineer to build a cost effective system.

  8. Polymersomes with asymmetric membranes and self-assembled superstructures using pentablock quintopolymers resolved by electron tomography

    Haataja, J. S.

    2018-01-09

    Polystyrene-block-poly(1,4-isoprene)-block-poly(dimethyl siloxane)-block-poly(tert-butyl methacrylate)-block-poly(2-vinyl pyridine), PS-b-PI-b-PDMS-b-PtBMA-b-P2VP, self-assembles in acetone into polymersomes with asymmetric (directional) PI-b-PDMS membranes. The polymersomes, in turn, self-assemble into superstructures. Analogically to supravesicular structures at a smaller length scale, we refer to them as suprapolymersome structures. Electron tomograms are shown to be invaluable in the structural assessment of such complex self-assemblies.

  9. Visualizing the photovoltaic behavior of a type-II p-n heterojunction superstructure

    Xing, Juanjuan, E-mail: xingjuanjuan@mail.sic.ac.cn [State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050 (China); Electron Microscopy Group, Surface Physics and Structure Unit, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Takeguchi, Masaki [Electron Microscopy Group, Surface Physics and Structure Unit, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Hashimoto, Ayako [Electron Microscopy Group, Surface Physics and Structure Unit, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Global Research Center for Environment and Energy Based on Nanomaterials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Cao, Junyu; Ye, Jinhua [International Center for Materials Nanoarchitectonics (WPI-MANA), 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan)

    2014-04-21

    Photovoltaic behavior of a CaFe{sub 2}O{sub 4}/ZnFe{sub 2}O{sub 4} p-n multi-junction was investigated with electron holography combined with an in situ light irradiation system. Potential profiles of the samples with and without light irradiation were extracted to measure the open circuit photovoltage generated either by the whole heterojunction superstructure or from each p-n junction. Investigation on the variation in the energy band configuration under light irradiation revealed the mechanism involved in the photoelectric effect, with respect to the properties of the heterojunction and its periodic quantum structure.

  10. Topotactic transformations of superstructures: from thin films to two-dimensional networks to nested two-dimensional networks.

    Guo, Chuan Fei; Cao, Sihai; Zhang, Jianming; Tang, Haoying; Guo, Shengming; Tian, Ye; Liu, Qian

    2011-06-01

    Design and synthesis of super-nanostructures is one of the key and prominent topics in nanotechnology. Here we propose a novel methodology for synthesizing complex hierarchical superstructures using sacrificial templates composed of ordered two-dimensional (2D) nanostructures through lattice-directed topotactic transformations. The fabricated superstructures are nested 2D orthogonal Bi(2)S(3) networks composed of nanorods. Further investigation indicates that the lattice matching between the product and sacrificial template is the dominant mechanism for the formation of the superstructures, which agrees well with the simulation results based on an anisotropic nucleation and growth analysis. Our approach may provide a promising way toward a lattice-directed nonlithographic nanofabrication technique for making functional porous nanoarchitectures and electronic devices. © 2011 American Chemical Society

  11. Outcomes Assessment of Treating Completely Edentulous Patients with a Fixed Implant-Supported Profile Prosthesis Utilizing a Graftless Approach. Part 1: Clinically Related Outcomes.

    Alzoubi, Fawaz; Bedrossian, Edmond; Wong, Allen; Farrell, Douglas; Park, Chan; Indresano, Thomas

    To assess outcomes of treating completely edentulous patients with a fixed implant-supported profile prosthesis utilizing a graftless approach for the maxilla and for the mandible, with emphasis on clinically related outcomes, specifically implant and prosthesis survival. This was a retrospective study with the following inclusion criteria: completely edentulous patients rehabilitated with a fixed implant-supported profile denture utilizing a graftless approach. Patients fulfilling the inclusion criteria were asked to participate in the study during their follow-up visits, and hence a consecutive sampling strategy was used. Data regarding implant and prosthesis cumulative survival rates (CSRs) were gathered and calculated. Thirty-four patients were identified with a total of 220 implants placed. An overall CSR of 98.2% was recorded with an observation of up to 10 years. For tilted, axial, and zygomatic implants, CSRs of 96.9%, 98.0%, and 100%, respectively, were observed for up to 10 years. For provisional prostheses, CSRs of 92.3% at 1 year, and 84.6% at 2 years were observed. For final prostheses, a CSR of 93.8% was observed at 10 years. The results suggest that treating completely edentulous patients with a fixed profile prosthesis utilizing a graftless approach in the maxilla and the mandible can be a reliable treatment option.

  12. Esthetic Outcome of Implant Supported Crowns With and Without Peri-Implant Conditioning Using Provisional Fixed Prosthesis: A Randomized Controlled Clinical Trial.

    Furze, David; Byrne, Ashley; Alam, Sonia; Wittneben, Julia-Gabriela

    2016-12-01

    Achieving an optimal esthetic result using dental implants is challenging. Fixed implant-supported provisional crowns are often used to customize the emergence profile and to individualize the surrounding peri-implant soft tissue. The objective of this study is to evaluate whether the use of a provisional implant-supported crown leads to an esthetic benefit on implants that are placed in the esthetic zone. The null hypothesis is that there is no-difference between the two study groups. Twenty single implants (Bone Level, Straumann AG, Basel, Switzerland) were inserted in consecutive patients. After reopening, a randomization process assigned them to either cohort group 1: a provisional phase with soft tissue conditioning using the "dynamic compression technique" or cohort group 2: without a provisional. Implants were finally restored with an all-ceramic crown. Follow-up examinations were performed at 3 and 12 months including implant success and survival, clinical, and radiographic parameters. After 1 year all implants successfully integrated, mean values of combined modPES and WES were 16.7 for group 1 and 10.5 for Group 2. This was statistically significant. Mean bone loss after 1 year was -0.09 and -0.08 for groups 1 and 2, respectively, without being statistically significant. A provisional phase with soft tissue conditioning does improve the final esthetic result. © 2016 Wiley Periodicals, Inc.

  13. Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.

    Ashmawy, Tarek Mohy; El Talawy, Dina Bahgat; Shaheen, Nasser Hussein

    2014-09-01

    To objectively evaluate the effect of mini-implant- supported mandibular overdentures on electromyographic activity (EMG) of the masseter muscle during chewing of hard and soft foods. Twelve completely edentulous patients (4 females and 8 males) with maladaptive experience of wearing mandibular dentures received new maxillary and mandibular dentures. After 3 months of adaptation, four mini dental implants (MDIs) were inserted in the interforaminal region of the mandible, and the new mandibular dentures were connected to the implants immediately with O/ring attachments. The activity of masseter muscle (EMG) and the duration of chewing cycle were measured during chewing hard (carrot) and soft (gum) foods. The measurements were made 3 months after wearing each of the following prostheses: the new conventional dentures; and the MDI-retained mandibular overdentures. The EMG of masseter muscle increased and the DC decreased with MDI-retained mandibular overdentures when compared to conventional dentures. Hard food (carrot) was associated with increased EMG and decreased DC when compared to soft food (gum) for both conventional dentures and MDI-retained mandibular overdentures. Mini-implant-supported mandibular overdentures are associated with increased activity of masseter muscle and decreased duration of chewing cycle for both hard and soft foods when compared to conventional dentures.

  14. Using individual two-posterior short implants with two-anterior standard implants in mandibular implant-supported-overdenture to enhance the patient satisfaction: A clinical report

    Mehran Bahrami

    2017-01-01

    Full Text Available Introduction: Many clinical cases and the literature review have revealed implant-supported-overdentures’ (ISOs treatment success and predictability in elderly patients. According to the previous studies, all the mandibular ISOs used 2–4 implants anterior to mental foramen to retain the denture. Case Report: In this clinical report, two individual anterior standard implants and two individual posterior short implants were used to support the mandibular ISO, as well as to prevent further posterior bone resorption. This treatment option permits the patient to insert more implants in the future, and could be upgraded to implant-supported-fixed prosthesis. Discussion: The patient was completely satisfied about the final result, especially for upgrading the mastication efficiency. The patient was followed-up for more than 2 years without complication. The panoramic X-ray showed the preserved bone in the posterior region. This technique could be considered to be innovative, and more clinical cases are required to be documented as a predictable modality.

  15. Implant-Supported Telescopic Crown-Retained Overdentures for Oral Rehabilitation of Patients with Severe Bony Defects: A 5-Year Retrospective Study.

    Zou, Duohong; Wang, Feng; Wu, Yiqun; Huang, Wei; Zhang, Chenping; Zhang, Zhiyuan

    2015-01-01

    To evaluate the performance of dental implant-supported telescopic crown (TC)-retained overdentures to restore the oral function of patients who have insufficient jawbone volume resulting from tumor resection or trauma. From January 2004 to December 2008, implant-supported TC-retained overdentures were used to restore the oral function of patients with severe bony defects resulting from tumor resection or trauma. Clinical data, including implant success and survival rates, biologic and mechanical complications, prosthodontic maintenance efforts, and patient satisfaction, were analyzed annually after delivery of the final prostheses. Twenty-four patients were treated, and a total of 88 implants were inserted to support TC-retained overdentures. The mean modified plaque index of implants remained low (76.3%) in the study showed the absence of bleeding on probing at follow-up visits. Peri-implant marginal bone loss (MBL) ranged from 0.8 to 1.2 mm. There was no statistically significant difference in the MBL between maxillary and mandibular implants (P = .43). The implant success rate was 100% after 5 years, and the prosthodontic maintenance and complication rate was 0.22 times per year. More than 90% of patients were satisfied with the restoration of their oral function using TCs. Based on our study of 24 patients treated with TC-retained overdentures, it appears that this treatment may be a viable option for patients with insufficient jawbone volume.

  16. Experimental Investigation of a Self-Sensing Hybrid GFRP-Concrete Bridge Superstructure with Embedded FBG Sensors

    Wang, Yanlei; Li, Yunyu; Ran, Jianghua; Cao, Mingmin

    2012-01-01

    A self-sensing hybrid GFRP-concrete bridge superstructure, which consists of two bridge decks and each bridge deck is comprised of four GFRP box sections combined with a thin layer of concrete in the compression zone, was developed by using eight embedded FBG sensors in the top and bottom flanges of the four GFRP box sections at midspan section of one bridge deck along longitudinal direction, respectively. The proposed self-sensing hybrid bridge superstructure was tested in 4-point loading to...

  17. Comparative analysis of cogeneration power plants optimization based on stochastic method using superstructure and process simulator

    Araujo, Leonardo Rodrigues de [Instituto Federal do Espirito Santo, Vitoria, ES (Brazil)], E-mail: leoaraujo@ifes.edu.br; Donatelli, Joao Luiz Marcon [Universidade Federal do Espirito Santo (UFES), Vitoria, ES (Brazil)], E-mail: joaoluiz@npd.ufes.br; Silva, Edmar Alino da Cruz [Instituto Tecnologico de Aeronautica (ITA/CTA), Sao Jose dos Campos, SP (Brazil); Azevedo, Joao Luiz F. [Instituto de Aeronautica e Espaco (CTA/IAE/ALA), Sao Jose dos Campos, SP (Brazil)

    2010-07-01

    Thermal systems are essential in facilities such as thermoelectric plants, cogeneration plants, refrigeration systems and air conditioning, among others, in which much of the energy consumed by humanity is processed. In a world with finite natural sources of fuels and growing energy demand, issues related with thermal system design, such as cost estimative, design complexity, environmental protection and optimization are becoming increasingly important. Therefore the need to understand the mechanisms that degrade energy, improve energy sources use, reduce environmental impacts and also reduce project, operation and maintenance costs. In recent years, a consistent development of procedures and techniques for computational design of thermal systems has occurred. In this context, the fundamental objective of this study is a performance comparative analysis of structural and parametric optimization of a cogeneration system using stochastic methods: genetic algorithm and simulated annealing. This research work uses a superstructure, modelled in a process simulator, IPSEpro of SimTech, in which the appropriate design case studied options are included. Accordingly, the cogeneration system optimal configuration is determined as a consequence of the optimization process, restricted within the configuration options included in the superstructure. The optimization routines are written in MsExcel Visual Basic, in order to work perfectly coupled to the simulator process. At the end of the optimization process, the system optimal configuration, given the characteristics of each specific problem, should be defined. (author)

  18. Superstructure formation in PrNi_2Al_3 and ErPd_2Al_3

    Eustermann, Fabian; Hoffmann, Rolf-Dieter; Janka, Oliver; Oldenburg Univ.

    2017-01-01

    The intermetallic phase ErPd_2Al_3 was obtained by arc-melting of the elements and subsequent annealing for crystal growth. The sample was studied by X-ray diffraction on powders and single crystals. The structure of ErPd_2Al_3 was refined from X-ray diffraction data and revealed a superstructure of PrNi_2Al_3 - a CaCu_5 derivative (P6/m, a=1414.3(1), c=418.87(3) pm wR=0.0820, 1060 F"2 values, 48 variables). The same superstructure was subsequently found for PrNi_2Al_3 (P6/m, a=1407.87(4), c=406.19(2) pm, wR=0.0499, 904 F"2 values, 47 variables). In the crystal structure, the aluminium and transition metal atoms form a polyanionic network according to [T_2Al_3]"δ"-, while rare earth atoms fill cavities within the networks. They are coordinated by six transition metal and twelve aluminum atoms. In contrast to the PrNi_2Al_3 type structure reported so far, two crystallographic independent rare-earth sites are found of which one (1b) is shifted by 1/2 z, causing a distortion in the structure along with a recoloring of the T and Al atoms in the network.

  19. Dynamic cholesteric liquid crystal superstructures photoaligned by one-step polarization holography

    Li, Sen-Sen; Shen, Yuan; Chang, Zhen-Ni; Li, Wen-Song; Xu, Yan-Chao; Fan, Xing-Yu; Chen, Lu-Jian

    2017-12-01

    A convenient approach to modulate the fingerprint textures of methyl red (MR) doped cholesteric liquid crystals by asymmetric photoalignment in the green-light waveband is presented, resulting in the generation of voltage-controllable helical superstructures. The interaction between the MR molecules and the incident light polarization determines the initial twisted planar geometry, providing a multivariant control over the stripe directions of fingerprint textures by applying a proper electric field. The key factors for precise manipulation of fingerprint stripes in a predictable and rewritable manner are analyzed theoretically and investigated experimentally, which involves the alignment asymmetry, the ratio of cell gap to natural pitch length, and the chirality of chiral dopant. Dynamic periodic fingerprint textures in shapes of dashed curve and dashed line are further demonstrated by utilizing a facile one-step polarization holography process using two beams with orthogonal circular and orthogonal linear polarizations, respectively. It is believed that the practical approach described in this study would enrich the research contents of self-assembled hierarchical superstructures using soft liquid crystal building blocks.

  20. A 3-year prospective study of implant-supported, single-tooth restorations of all-ceramic and metal-ceramic materials in patients with tooth agenesis.

    Hosseini, Mandana; Worsaae, Nils; Schiødt, Morten; Gotfredsen, Klaus

    2013-10-01

    The purpose of this clinical study was to describe outcome variables of all-ceramic and metal-ceramic implant-supported, single-tooth restorations. A total of 59 patients (mean age: 27.9 years) with tooth agenesis and treated with 98 implant-supported single-tooth restorations were included in this study. Two patients did not attend baseline examination, but all patients were followed for 3 years. The implants supported 52 zirconia, 21 titanium and 25 gold alloy abutments, which retained 64 all-ceramic and 34 metal-ceramic crowns. At baseline and 3-year follow-up examinations, the biological outcome variables such as survival rate of implants, marginal bone level, modified Plaque Index (mPlI), modified Sulcus Bleeding Index (mBI) and biological complications were registered. The technical outcome variables included abutment and crown survival rate, marginal adaptation of crowns, cement excess and technical complications. The aesthetic outcome was assessed by using the Copenhagen Index Score, and the patient-reported outcomes were recorded using the OHIP-49 questionnaire. The statistical analyses were mainly performed by using mixed model of ANOVA for quantitative data and PROC NLMIXED for ordinal categorical data. The 3-year survival rate was 100% for implants and 97% for abutments and crowns. Significantly more marginal bone loss was registered at gold-alloy compared to zirconia abutments (P = 0.040). The mPlI and mBI were not significantly different at three abutment materials. The frequency of biological complications was higher at restorations with all-ceramic restorations than metal-ceramic crowns. Loss of retention, which was only observed at metal-ceramic crowns, was the most frequent technical complication, and the marginal adaptations of all-ceramic crowns were significantly less optimal than metal-ceramic crowns (P = 0.020). The professional-reported aesthetic outcome demonstrated significantly superior colour match of all-ceramic over metal

  1. Novel superstructure of the rocksalt type and element distribution in germanium tin antimony tellurides

    Rosenthal, Tobias [Department of Chemistry, Ludwig Maximilian University, Butenandtstraße 5-13, 81377 Munich (Germany); Welzmiller, Simon [Institute for Mineralogy, Crystallography and Materials Science, Leipzig University, Scharnhorststraße 20, 04275 Leipzig (Germany); Neudert, Lukas [Department of Chemistry, Ludwig Maximilian University, Butenandtstraße 5-13, 81377 Munich (Germany); Urban, Philipp [Institute for Mineralogy, Crystallography and Materials Science, Leipzig University, Scharnhorststraße 20, 04275 Leipzig (Germany); Fitch, Andy [European Synchrotron Radiation Facility, CS40220, 38043 Grenoble Cedex 9 (France); Oeckler, Oliver, E-mail: oliver.oeckler@gmx.de [Institute for Mineralogy, Crystallography and Materials Science, Leipzig University, Scharnhorststraße 20, 04275 Leipzig (Germany)

    2014-11-15

    A superstructure of the rocksalt-type observed in quenched CVT-grown single crystals of Ge{sub 3.25(7)}Sn{sub 1.10(3)}Sb{sub 1.10(3)}Te{sub 6} was elucidated by X-ray diffraction using fourfold twinned crystals (space group P3{sup ¯}m1, a=4.280(1) Å, c=20.966(3) Å). The structure is built up of distorted rocksalt-type building blocks typical for long-range ordered GST materials and substitution variants thereof. In contrast to those phases, an exclusive ABC-type cubic stacking sequence of the Te-atom layers is present. High-resolution electron microscopy reveals spheroidal domains with this structure (average diameter 25 nm) whose stacking direction is perpendicular to the 〈1 1 1〉 directions of the basic rocksalt-type structure. Additional slab-like domains with a lateral extension up to 1 µm occasionally result in a hierarchical structure motif. Due to the similar electron counts of the elements involved, resonant diffraction was used in order to elucidate the element distribution in rocksalt-type building blocks of the stable layered compound 39R-Ge{sub 3}SnSb{sub 2}Te{sub 7} (R3{sup ¯}m, a=4.24990(4) Å, c=73.4677(9) Å). Sb tends to occupy the atom site close to the van der Waals gaps while Ge concentrates in the center of the building blocks. - Graphical abstract: High-resolution transmission electron micrograph, SAED pattern and reciprocal lattice section of X-ray single crystal data of Ge{sub 3.25}Sn{sub 1.1}Sb{sub 1.1}Te{sub 6} with an 11P-type superstructure of the rocksalt type. - Highlights: • A novel superstructure of the rocksalt-type in the system Ge–Sn–Sb–Te is elucidated. • It combines the cubic stacking of the HT phase with building blocks of the RT phase. • It indicates the ordering mechanism during the phase transition of GST materials. • A hierarchical structure motif is promising with respect to the reduction of κ{sub L}. • Resonant diffraction reveals the element distribution in 39R-Ge{sub 3}SnSb{sub 2}Te{sub 7}.

  2. Study on superstructure in ion co-doped BiFeO3 by using transmission electron microscopy

    Pu, Shi-Zhou; Guo, Chao; Li, Mei-Ya; Chen, Zhen-Lian; Zou, Hua-Min

    2015-04-01

    La3+ and V5+ co-doped BiFeO3 ceramics are synthesized by rapid liquid sintering technique. The modulated structure in Bi0.85La0.15Fe0.97V0.03O3 is investigated by using transmission electron microscopy (TEM). Two kinds of superstructures are observed in the samples. One is the component modulated superstructure and twin-domain, which is generated by La3+ ordered substitution for Bi3+ and frequently appears. The chemical composition of the superstructure is explored by x-ray energy dispersive spectroscopy (EDS). The model of the ordered structure is proposed. Simulation based on the model is conducted. The second is the fluorite-type δ-Bi2O3 related superstructure. The relation between the ferroelectric property and the microstructure of the sample is also discussed. Project supported by the National Natural Science Foundation of China (Grant Nos. 51372174, 11074193, and 51132001) and the Fundamental Research Funds for the Central Universities.

  3. A Critical Reassessment of Marxian Base-Superstructure Explanations of the Role of Education in Social Change.

    Chun, Kyung-Kap

    1986-01-01

    Examines how four major versions of neo-Marxism (i.e., Hegelian, Phenomenological, Structuralist Marxism, and the Frankfurt School) attempt to overcome the base-superstructure thesis of the political economists of education. Considers the implicit social ontological and epistemological assumptions and the related theory of education of each.…

  4. An analysis of reliability and validity of the papilla index score of implant-supported single crowns of maxillary central incisors

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2012-01-01

    Objectives: To test the reliability and validity of the papilla index scores of the implant-supported single crowns (ISSCs) of maxillary central incisors. Materials and Methods: Twenty-five patients with 25 ISSCs were included. Two prosthodontists evaluated the papilla index score (PIS) of three...... inter-observer agreement. The PIS score demonstrated significant correlation to the corresponding PP value (rs=.567, p=.000). Conclusions: The feasibility, reliability and validity of the PIS made the parameter useful for quality control of the pri-implant soft tissue of ISSCs....... fill percent (PP) was calculated. The validity of PIS was tested against the corresponding papilla fill percent (PP) by using the Spearman correlation analysis. Results: The intra-observer agreement was >70% in 4/5 and >50% in all observations, the pooled Cohen’s ¿ was 0.64 and 0.70 for two observers...

  5. A 3-year prospective study of implant-supported, single-tooth restorations of all-ceramic and metal-ceramic materials in patients with tooth agenesis

    Hosseini, Mandana; Worsaae, Nils; Schiødt, Morten

    2013-01-01

    -tooth restorations were included in this study. Two patients did not attend baseline examination, but all patients were followed for 3 years. The implants supported 52 zirconia, 21 titanium and 25 gold alloy abutments, which retained 64 all-ceramic and 34 metal-ceramic crowns. At baseline and 3-year follow......-up examinations, the biological outcome variables such as survival rate of implants, marginal bone level, modified Plaque Index (mPlI), modified Sulcus Bleeding Index (mBI) and biological complications were registered. The technical outcome variables included abutment and crown survival rate, marginal adaptation...... and PROC NLMIXED for ordinal categorical data. RESULTS: The 3-year survival rate was 100% for implants and 97% for abutments and crowns. Significantly more marginal bone loss was registered at gold-alloy compared to zirconia abutments (P = 0.040). The mPlI and mBI were not significantly different at three...

  6. Maxillary and mandibular immediately loaded implant-supported interim complete fixed dental prostheses on immediately placed dental implants with a digital approach: A clinical report.

    Lewis, Ryan C; Harris, Bryan T; Sarno, Robert; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao

    2015-09-01

    This clinical report describes the treatment of maxillary and mandibular immediate implant placement and immediately loaded implant-supported interim complete fixed dental prostheses with a contemporary digital approach. The virtual diagnostic tooth arrangement eliminated the need for a customized radiographic template, and the diagnostic data collection required for computer-guided surgery (digital diagnostic impressions, digital photographs, and a cone beam-computed tomography [CBCT] scan) was completed in a single visit with improved workflow efficiency. Computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated surgical templates and interim prosthesis templates were made in a dental laboratory to facilitate computer-guided surgery and the immediate loading process. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Biomechanical evaluation of the natural abutment teeth in combined tooth-implant-supported telescopic prostheses: a three-dimensional finite element analysis.

    Chen, Yu; Wang, Chao; Huang, Yuanding; Feng, Tianming; Zou, Huawei; Fan, Yubo

    2017-07-01

    Telescopic overdentures supported by the combination of natural teeth and implants have been thought a valuable treatment for the severely compromised partially edentulous patients. But the combination of teeth and implants involves highly complex biomechanical problems. This study is to evaluate biomechanical behaviors of the natural abutment teeth with the treatment of combined tooth-implant supported telescopic crown prostheses in mandible through 3D FEA. According to this study, the prosthetic option supported by a combination of teeth and implants and retained by double crowns could protect teeth and their periodontal support tissues acting as a rigid splint, and may be a valuable treatment option for partially edentulous patients with severely reduced remaining teeth in mandible.

  9. Extended and quasi-continuous tuning of quantum cascade lasers using superstructure gratings and integrated heaters

    Bidaux, Yves, E-mail: yves.bidaux@alpeslasers.ch [Alpes Lasers SA, 1-3 Passsage Max Meuron, CH-2001 Neuchâtel (Switzerland); Institute for Quantum Electronics, ETH-Zurich, CH-8093 Zurich (Switzerland); Bismuto, Alfredo, E-mail: alfredo.bismuto@alpeslasers.ch; Tardy, Camille; Terazzi, Romain; Gresch, Tobias; Blaser, Stéphane; Muller, Antoine [Alpes Lasers SA, 1-3 Passsage Max Meuron, CH-2001 Neuchâtel (Switzerland); Faist, Jerome [Institute for Quantum Electronics, ETH-Zurich, CH-8093 Zurich (Switzerland)

    2015-11-30

    In this work, we demonstrate broad electrical tuning of quantum cascade lasers at 9.25 μm, 8.5 μm, and 4.4 μm in continuous wave operation using Vernier-effect distributed Bragg reflectors based on superstructure gratings. Integrated micro-heaters allow to switch from one Vernier channel to the other, while predictable and mode-hop free tuning can be obtained in each channel modulating the laser current with a side mode suppression ratio as high as 30 dB. The resulting device behaves effectively as a switchable multicolour tunable source. Tuning up to 6.5% of the central wavelength is observed. To prove the importance of the developed devices for high resolution molecular spectroscopy, a N{sub 2}O absorption spectrum has been measured.

  10. Unsupervised Performance Evaluation Strategy for Bridge Superstructure Based on Fuzzy Clustering and Field Data

    Yubo Jiao

    2013-01-01

    Full Text Available Performance evaluation of a bridge is critical for determining the optimal maintenance strategy. An unsupervised bridge superstructure state assessment method is proposed in this paper based on fuzzy clustering and bridge field measured data. Firstly, the evaluation index system of bridge is constructed. Secondly, a certain number of bridge health monitoring data are selected as clustering samples to obtain the fuzzy similarity matrix and fuzzy equivalent matrix. Finally, different thresholds are selected to form dynamic clustering maps and determine the best classification based on statistic analysis. The clustering result is regarded as a sample base, and the bridge state can be evaluated by calculating the fuzzy nearness between the unknown bridge state data and the sample base. Nanping Bridge in Jilin Province is selected as the engineering project to verify the effectiveness of the proposed method.

  11. Growth and Transfer of Monolithic Horizontal ZnO Nanowire Superstructures onto Flexible Substrates

    Xu, Sheng

    2010-04-28

    A method of fabricating horizontally aligned ZnO nanowire (NW) arrays with full control over the width and length is demonstrated. A cross-sectional view of the NWs by transmission electron microscopy shows a "mushroom-like" structure. Novel monolithic multisegment superstructures are fabricated by making use of the lateral overgrowth. Ultralong horizontal ZnO NWs of an aspect ratio on the order often thousand are also demonstrated. These horizontal NWs are lifted off and transferred onto a flexible polymer substrate, which may have many great applications in horizontal ZnO NW-based nanosensor arrays, light-emitting diodes, optical gratings, integrated circuit interconnects, and high-output-power alternating-current nanogenerators. © 2010 WILEY-VCH Verlag GmbH & Co. KGaA.

  12. Synthesis of noble metal nanoparticles and their superstructures; Darstellung von Edelmetallnanopartikeln und deren Ueberstrukturen

    Bigall, Nadja-Carola

    2009-08-18

    A modified synthesis procedure for citrate-stabilized gold nanoparticles in aqueous solution is transferred under application of equal concentrations to the systems silver, platinum, and palladium. The nanoparticles are analyzed by means of absorption spectroscopy and electron microscopy. Ordered superstructures of the noble-metal nanoparticles can be synthesized by infiltration of templates of block-copolymer films with aqueous nanoparticle solution. In dependence on the pre-treatment of the polymer films either two-dimensional periodical arrangements with a periodicity of less than 30 nm or fingerprint-like arrangements with a groove distance in the same order of magnitude. By removal of the polymer one- respectively two-dimensional arrangements of platinum nanowires respectively nanoparticles on a silicon waver arise.

  13. Systematic network synthesis and design: Problem formulation, superstructure generation, data management and solution

    Quaglia, Alberto; Gargalo, Carina L.; Chairakwongsa, Siwanat

    2015-01-01

    when large problems are considered. In an earlier work, we proposed a computer-aided framework for synthesis and design of process networks. In this contribution, we expand the framework by including methods and tools developed to structure, automate and simplify the mathematical formulation......The developments obtained in recent years in the field of mathematical programming considerably reduced the computational time and resources needed to solve large and complex Mixed Integer Non Linear Programming (MINLP) problems. Nevertheless, the application of these methods in industrial practice...... is still limited by the complexity associated with the mathematical formulation of some problems. In particular, the tasks of design space definition and representation as superstructure, as well as the data collection, validation and handling may become too complex and cumbersome to execute, especially...

  14. Superstructure of self-aligned hexagonal GaN nanorods formed on nitrided Si(111) surface

    Kumar, Praveen; Tuteja, Mohit; Kesaria, Manoj; Waghmare, U. V.; Shivaprasad, S. M. [Jawaharlal Nehru Centre for Advanced Scientific Research, Jakkur, Bangalore 560 064 (India)

    2012-09-24

    We present here the spontaneous formation of catalyst-free, self-aligned crystalline (wurtzite) nanorods on Si(111) surfaces modified by surface nitridation. Nanorods grown by molecular beam epitaxy on bare Si(111) and non-stoichiometric silicon nitride interface are found to be single crystalline but disoriented. Those grown on single crystalline Si{sub 3}N{sub 4} intermediate layer are highly dense c-oriented hexagonal shaped nanorods. The morphology and the self-assembly of the nanorods shows an ordered epitaxial hexagonal superstructure, suggesting that they are nucleated at screw dislocations at the interface and grow spirally in the c-direction. The aligned nanorod assembly shows high-quality structural and optical emission properties.

  15. Experimental and theoretical study of the operation of longitudinal sidewalls in reinforced concrete superstructures

    Bokarev, Sergey; Efimov, Stefan

    2017-11-01

    In the present article, we report results of a laboratory experimental study of reinforced-concrete superstructure fragments with extended longitudinal boxing sidewalls. The study included laboratory tests and numerical experiments performed using a finite element model of fragments generated in specialized simulation software. The distribution of horizontal pressures over the height of longitudinal boxing sidewalls, the dependence of the bending moment in the root section of the sidewalls on the ballast-bed thickness under sleepers, and some other characteristics were examined. The results of the experimental and theoretical study have shown a good convergence of obtained data to each other and to the data obtained by an improved engineering calculation procedure proposed by the present authors.

  16. 動漫畫運用在民主政治相關課程上的另類嘗試:以《航海王》為例 The Application of Animation and Comics Democratic Politics Courses: A Study of the ONE PIECE

    蔡偉銑 Wei-Hsien Tsai

    2012-12-01

    Full Text Available 近年部分教科書、大學與企業開始正視動漫畫結合視覺藝術與文字敘事、兼顧娛樂性與知識性的特性,並嘗試以動漫畫形式來說明與認識各種複雜的議題。本文以連載超過十年的知名動漫畫《航海王》為分析對象,指出其藉由荒誕誇張的情節,暗寓脈絡一致的嚴肅性議題:對權力與政府的戒懼,對人性與理想的堅持,以及對主流歷史與正義等概念的檢視。對比傳統學術性課程的學習方式,動漫畫透過娛樂效果的包裝,或許更能適性地吸引較為缺乏人文素養背景的學生,來思索這些沉重嚴肅,但卻緊扣社會脈動的議題,顯 示動漫畫所可能蘊含的意象、故事和寓言,或許在調整傳統學術式學習方式、尋求課程與教材創新的各種嘗試中,有值得我們重視之處。 In recent years, some universities and corporations have begun incorporating animations and comics into their teaching materials, which may also include visual arts and written narratives, finding that these can be both entertaining and intellectually stimulating. In this paper, I show how the application of entertaining and attractive animation and comics as teaching materials for general democratic education classes is more effective than traditional materials, especially for students of diverse backgrounds. The paper offers a textual analysis of ONE PIECE, an animation and comic series from Japan popular among college students in Taiwan. I discuss and survey the metaphors found within the often exaggerated and absurd stories, relating them to themes such as the nature of government, justice and authority.

  17. Evaluation of the influence exerted by different dental specialty backgrounds and measuring instrument reproducibility on esthetic aspects of maxillary implant-supported single crown.

    Vaidya, Samriddhi; Ho, Yu Lau Elaine; Hao, Jie; Lang, Niklaus P; Mattheos, Nikos

    2015-03-01

    To evaluate the influence exerted by different dental specialty backgrounds as well as the validity and reproducibility of the Pink Esthetic Score/White Esthetic Score (PES/WES) and the modified Implant Crown Aesthetic Index (mod-ICAI) on the assessment of esthetic aspects of maxillary implants supported single-tooth prosthesis. A total of fourteen examiners (Two orthodontists, two prosthodontists, two oral surgeons, two periodontists, two dental technicians, two dental assistants, and two postgraduate students in Implant Dentistry evaluated 20 photographs of single-implant-supported crowns and five photographs of unrestored teeth of esthetic zone in a two part study. The examiners assessed the photographs with each index (Pink Esthetic Score/White Esthetic Score and modified Implant Crown Aesthetic Index), twice with a week's interval. Orders of photographs were rearranged in the second assessment. Kruskal-Wallis test results showed significant differences among all the six specialties (P ≤ 0.001). DAs and periodontists had significantly better ratings than other specialties with both indices. Prosthodontists had the lowest mean rank scores regardless of the index. Interobserver agreement was also lowest between the two prosthodontists (4-28%), rest of the groups had low-to-moderate agreement (20-80%) when limited allowance was accepted. With mod-ICAI, more interobserver agreement was noted within the specialty group than with PES/WES. The PES/WES and the modified ICAI can be reliable estimates of esthetic outcomes. The assessor degree of specialization affected the esthetic evaluation with both the PES/WES and the modified ICAI. DAs and periodontists were identified to provide more favorable ratings than other specialties while prosthodontists were most critical in this study. With modified ICAI, more interobserver agreement within specialty resulted. The interexaminer agreement may be increased if more tolerance of 1-2 points is considered. © 2014 John Wiley

  18. In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion.

    Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria; Francischone, Carlos Eduardo; de Mattos, Maria da Gloria Chiarello

    2004-08-01

    For implant-supported prostheses, passive fit is critical for the success of rehabilitation, especially when alternative materials are used. The purpose of this study was to compare interfacial fit of implant-supported prostheses cast in titanium to those cast in gold alloy. Five 3-unit fixed partial dentures were fabricated in gold alloy (Degudent U) as 1-piece castings, and 5 others were similarly cast in commercially pure titanium (Grade 1). The interfacial gaps between the prostheses and the abutments were evaluated with an optical microscope, before and after electroerosion. Readings were made with both screws tightened (10 N.cm torque), and with only 1 side tightened, so as to also evaluate the passive fit of the prostheses. Data were compared statistically by 2-way analysis of variance and the post hoc Tukey multiple range test (alpha=.05). Before electroerosion, the interfacial gaps for the 1-piece prostheses were significantly smaller (Pelectroerosion procedure significantly (Pelectroerosion did not present significant differences when the side opposite the tightened side was analyzed, but the gold alloy group showed better fit when the tightened side was analyzed (12.8 +/- 1.4 microm for gold alloy; 29.6 +/- 4.4 microm for titanium) and when both screws were tightened (5.4 +/- 2.3 microm for gold alloy; 16.1 +/- 5.5 microm for titanium). Cast titanium prostheses, despite showing larger interfacial gaps between the prosthesis and abutment than those obtained with gold alloy, had improved fit after being subjected to electroerosion.

  19. Heat-cured acrylic resin versus light-activated resin: a patient, professional and technician-based evaluation of mandibular implant-supported overdentures.

    Asal, S A; Al-AlShiekh, H M

    2017-12-01

    Although light-activated resins (Eclipse) have been reported to possess superior physical and mechanical properties compared with the heat-cured acrylic resins (Lucitone-199), a few studies have compared overdentures with a locator attachment constructed from heat-cured acrylic resins with those constructed from light-activated resins. This clinical study was designed to compare the performance of a mandibular implant-supported overdenture constructed from a heat-cured acrylic resin (Lucitone-199) with that of an overdenture constructed from a light-activated resin (Eclipse). Ten participants received two identical mandibular implant-retained overdentures (Lucitone-199 and Eclipse) opposing one maxillary denture in a random order. Each mandibular overdenture was delivered and worn for 6 months, and two weeks of rest was advised between wears to minimize any carryover effects. Three questionnaires were devised. The first questionnaire (patient evaluation) focused on evaluating different aspects of the denture and overall satisfaction. The second questionnaire (professional dentist evaluation) was based on a clinical evaluation of soft tissues, complications, and the applied technique. The third questionnaire (technician evaluation) involved ranking the different manufacturing steps of the denture and overall preferences. The obtained data was statistically analyzed using an independent sample t-test and the Wilcoxon rank-sum test. The clinician and technician preferred the Eclipse dentures because of their technical aspects, whereas the patients preferred the Lucitone-199 dentures for their aesthetic properties. Implant-supported overdentures constructed from a heat-cured acrylic resin showed superior aesthetics and had a better odor compared with those constructed from a light-cured resin.

  20. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.

    De Kok, Ingeborg J; Chang, Kuang-Han; Lu, Tsui-Shan; Cooper, Lyndon F

    2011-01-01

    The mandibular two-implant overdenture has been shown to be a highly successful treatment. However, overdenture patients who desire a fixed prosthesis may not be satisfied with a removable overdenture. This prospective study sought to compare prosthetic outcomes, patient satisfaction, and survival rates of implants between two-implant-supported overdentures (IODs) and three-implant-supported fixed dentures (ISFDs). Twenty completely edentulous patients were randomly and equally assigned to two groups. New conventional complete dentures were made, and the mandibular denture was used as a surgical guide during implant placement. Implants were placed in one stage, followed by a mandibular denture soft reline (provisional loading). Ball attachments were inserted at 8 weeks, and ISFDs were delivered at 16 weeks. IODs were connected to the attachments at 8 weeks, using each patients's existing denture. The definitive ISFDs were fabricated using computer-aided design/computer-assisted manufacture milled titanium frameworks and acrylic resin base and teeth. Patient satisfaction and panoramic radiographs were investigated at 6 and 12 months. Both treatments had significant and positive effects on patient satisfaction and quality of life. None of the 50 implants placed had failed at 12 months of follow-up; therefore, the implant survival rate was 100%. Prosthetic complications were generally rare and easily manageable. Both the treatment modalities-the ISFD supported by three implants and the IOD supported by two implants-significantly and similarly improved patient satisfaction and oral health-related quality of life, and prosthetic complications were relatively rare for both treatments. Three implants can be used to support a mandibular fixed prosthesis; however, a longer observation period is needed to validate this treatment modality.

  1. Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents.

    Castillo-de-Oyagüe, Raquel; Sánchez-Turrión, Andrés; López-Lozano, José-Francisco; Albaladejo, Alberto; Torres-Lagares, Daniel; Montero, Javier; Suárez-García, Maria-Jesús

    2012-07-01

    This study aimed to evaluate the vertical discrepancy of implant-supported crown structures constructed with vacuum-casting and Direct Metal Laser Sintering (DMLS) technologies, and luted with different cement types. Crown copings were fabricated using: (1) direct metal laser sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC); and (3) vacuum-cast Ti (CT). Frameworks were luted onto machined implant abutments under constant seating pressure. Each alloy group was randomly divided into 5 subgroups (n = 10 each) according to the cement system utilized: Subgroup 1 (KC) used resin-modified glass-ionomer Ketac Cem Plus; Subgroup 2 (PF) used Panavia F 2.0 dual-cure resin cement; Subgroup 3 (RXU) used RelyX Unicem 2 Automix self-adhesive dual-cure resin cement; Subgroup 4 (PIC) used acrylic/urethane-based temporary Premier Implant Cement; and Subgroup 5 (DT) used acrylic/urethane-based temporary DentoTemp cement. Vertical misfit was measured by scanning electron microscopy (SEM). Two-way ANOVA and Student-Newman-Keuls tests were run to investigate the effect of alloy/fabrication technique, and cement type on vertical misfit. The statistical significance was set at α = 0.05. The alloy/manufacturing technique and the luting cement affected the vertical discrepancy (p Laser sintering may be an alternative to vacuum-casting of base metals to obtain passive-fitting implant-supported crown copings. The best marginal adaptation corresponded to laser sintered structures luted with glass-ionomer KC, or temporary PIC or DT cements. The highest discrepancies were recorded for Co-Cr and Ti cast frameworks bonded with PF or RXU resinous agents. All groups were within the clinically acceptable misfit range.

  2. Prevention of Cutaneous Tissue Contracture During Removal of Craniofacial Implant Superstructures for CT and MRI Studies

    Maureen Sullivan

    2010-04-01

    Full Text Available Objectives: Head and neck cancer patients who have lost facial parts following surgical intervention frequently require craniofacial implant retained facial prostheses for restoration. Many craniofacial implant patients require computed tomography and magnetic resonance imaging scans as part of their long-term follow-up care. Consequently removal of implant superstructures and peri-abutment tissue management is required for those studies. The purpose of the present paper was to describe a method for eliminating cranial imaging artifacts in patients with craniofacial implants.Material and Methods: Three patients wearing extraoral implant retained facial prostheses needing either computed tomography or magnetic resonance imaging studies were discussed. Peri-implant soft tissues contracture after removal of percutaneous craniofacial implant abutments during computed tomography and magnetic resonance imaging studies was prevented using a method proposed by authors. The procedure involves temporary removal of the supra-implant components prior to imaging and filling of the tissue openings with polyvinyl siloxane dental impression material.Results: Immediately after filling of the tissue openings with polyvinyl siloxane dental impression material patients were sent for the imaging studies, and were asked to return for removal of the silicone plugs and reconnection of all superstructure hardware after imaging procedures were complete. The silicone plugs were easily removed with a dental explorer. The percutaneous abutments were immediately replaced and screwed into the implants which were at the bone level.Conclusions: Presented herein method eliminates the source of artifacts and prevents contracture of percutaneous tissues upon removal of the implant abutments during imaging.

  3. Enhanced fullerene–Au(111 coupling in (2√3 × 2√3R30° superstructures with intermolecular interactions

    Michael Paßens

    2015-06-01

    Full Text Available Disordered and uniform (2√3 × 2√3R30° superstructures of fullerenes on the Au(111 surface have been studied using scanning tunneling microscopy and spectroscopy. It is shown that the deposition and growth process of a fullerene monolayer on the Au(111 surface determine the resulting superstructure. The supply of thermal energy is of importance for the activation of a Au vacancy forming process and thus, one criterion for the selection of the respective superstructure. However, here it is depicted that a vacancy–adatom pair can be formed even at room temperature. This latter process results in C60 molecules that appear slightly more bright in scanning tunnelling microscopy images and are identified in disordered (2√3 x 2√3R30° superstructures based on a detailed structure analysis. In addition, these slightly more bright C60 molecules form uniform (2√3 x 2√3R30° superstructures, which exhibit intermolecular interactions, likely mediated by Au adatoms. Thus, vacancy–adatom pairs forming at room temperature directly affect the resulting C60 superstructure. Differential conductivity spectra reveal a lifting of the degeneracy of the LUMO and LUMO+1 orbitals in the uniform (2√3 x 2√3R30° superstructure and in addition, hybrid fullerene–Au(111 surface states suggest partly covalent interactions.

  4. Simultaneous measurement of temperature and tensile loading using superstructure FBGs developed by laser direct writing of periodic on-fiber metallic films

    Alemohammad, Hamidreza; Toyserkani, Ehsan

    2009-01-01

    This paper addresses the development of superstructure fiber Bragg gratings (FBGs) by laser-assisted direct writing of on-fiber metallic films. A novel laser direct write method is characterized to fabricate periodic films of silver nanoparticles on the non-planar surface of as-fabricated FBGs. Silver films with a thickness of 9 µm are fabricated around a Bragg grating optical fiber. The performance of the superstructure FBG is studied by applying temperature and tensile stress on the fiber. An opto-mechanical model is also developed to predict the optical response of the synthesized superstructure FBG under thermal and structural loadings. The results show that the reflectivity of sidebands in the reflection spectrum can be tuned up to 20% and 37% under thermal and structural loadings, respectively. In addition, the developed superstructure FBG is used for simultaneous measurement of force and temperature to eliminate the inherent limitation of regular FBGs in multi-parameter sensing

  5. Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year.

    Gargari, M; Prete, V; Pujia, M; Ceruso, F M

    2012-10-01

    Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year. The aim of this study is to compare functional efficiency and patients satisfaction between tooth-supported and implant-supported overdenture through a questionnaire that accurately reflects the real concerns of patients with dental prosthesis. Forty-three patients were selected from the out patient clinic, Department of Dentistry "Fra G.B. Orsenigo Ospedale San Pietro F.B.F.", Rome, Italy. Their age were ranging from 61 to 83 years. Eighteen patients were rehabilitated with overdentures supported by natural teeth and twenty-five with overdentures implant-supported. DISCUSSION AND RESULT: The questionnaire proposed one year after the insertion of the prosthetis has showed that there isn't difference statistically significant in terms of function, phonetics and aesthetics between overdenture implant-supported and tooth-supported. The results of the questionnaire showed that the patients generally had a high level of satisfaction concern to the masticatory function, esthetics and phonetics. In addition, on average, they haven't difficulty in removal and insertion of the denture and in oral hygiene. They haven't in both groups problems related to fractures.

  6. [Influence of coping material selection and porcelain firing on marginal and internal fit of computer-aided design/computer- aided manufacturing of zirconia and titanium ceramic implant-supported crowns].

    Cuiling, Liu; Liyuan, Yang; Xu, Gao; Hong, Shang

    2016-06-01

    This study aimed to investigate the influence of coping material and porcelain firing on the marginal and internal fit of computer-aided design/computer-aided manufacturing (CAD/CAM) of zirconia ceramic implant- and titanium ceramic implant-supported crowns. Zirconia ceramic implant (group A, n = 8) and titanium metal ceramic implant-supported crowns (group B, n = 8) were produced from copings using the CAD/CAM system. The marginal and internal gaps of the copings and crowns were measured by using a light-body silicone replica technique combined with micro-computed tomography scanning to obtain a three-dimensional image. Marginal gap (MG), horizontal marginal discrepancy (HMD), and axial wall (AW) were measured. Statistical analyses were performed using SPSS 17.0. Prior to porcelain firing, the measurements for MG, HMD, and AW of copings in group A were significantly larger than those in group B (P 0.05). Porcelain firing significantly reduced MG (P 0.05). The marginal fits of CAD/CAM zirconia ceramic implant-supported crowns were superior to those of CAD/CAM titanium ceramic-supported crowns. The fits of both the CAD/CAM zirconia ceramic implant- and titanium ceramic implant-supported crowns were obviously influenced by porcelain firing.

  7. In vitro comparison of fracture load of implant-supported, zirconia-based, porcelain- and composite-layered restorations after artificial aging.

    Komine, Futoshi; Taguchi, Kohei; Fushiki, Ryosuke; Kamio, Shingo; Iwasaki, Taro; Matsumura, Hideo

    2014-01-01

    This study evaluated fracture load of single-tooth, implant-supported, zirconia-based, porcelain- and indirect composite-layered restorations after artificial aging. Forty-four zirconia-based molar restorations were fabricated on implant abutments and divided into four groups, namely, zirconia-based all-ceramic restorations (ZAC group) and three types of zirconia-based composite-layered restorations (ZIC-P, ZIC-E, and ZIC groups). Before layering an indirect composite material, the zirconia copings in the ZIC-P and ZIC-E groups were primed with Clearfil Photo Bond and Estenia Opaque Primer, respectively. All restorations were cemented on the abutments with glass-ionomer cement and then subjected to thermal cycling and cyclic loading. All specimens survived thermal cycling and cyclic loading. The fracture load of the ZIC-P group (2.72 kN) was not significantly different from that of the ZAC group (3.05 kN). The fracture load of the zirconia-based composite-layered restoration primed with Clearfil Photo Bond (ZIC-P) was comparable to that of the zirconia-based all-ceramic restoration (ZAC) after artificial aging.

  8. Transition from failing dentition to full-arch fixed implant-supported prosthesis with a staged approach using removable partial dentures: a case series.

    Cortes, Arthur Rodriguez Gonzalez; Cortes, Djalma Nogueira; No-Cortes, Juliana; Arita, Emiko Saito

    2014-06-01

    The present retrospective case series is aimed at evaluating a staged approach using a removable partial denture (RPD) as an interim prosthesis in treatment to correct a failing dentition until such time as a full-arch fixed implant-supported prosthesis may be inserted. Eight patients, who had undergone maxillary full-arch rehabilitation with dental implants due to poor prognosis of their dentitions, were analyzed. All treatment included initial periodontal therapy and a strategic order of extraction of hopeless teeth. An RPD supported by selected teeth rehabilitated the compromised arch during implant osseointegration. These remaining teeth were extracted prior to definitive prosthesis delivery. Advantages and drawbacks of this technique were also recorded for the cases presented. Among the advantages provided by the staged approach are simplicity of fabrication, low cost, and ease of insertion. Additionally, RPD tooth support prevented contact between the interim prosthesis and healing abutments, promoting implant osseointegration. The main drawbacks were interference with speech and limited esthetic results. Implant survival rate was 100% within a follow-up of at least 1 year. The use of RPDs as interim prostheses allowed for the accomplishment of the analyzed rehabilitation treatments. It is a simple treatment alternative for patients with a low smile line. © 2013 by the American College of Prosthodontists.

  9. Retrospective comparative ten-year study of cumulative survival rates of remaining teeth in large edentulism treated with implant-supported fixed partial dentures or removable partial dentures.

    Yamazaki, Seiya; Arakawa, Hikaru; Maekawa, Kenji; Hara, Emilio Satoshi; Noda, Kinji; Minakuchi, Hajime; Sonoyama, Wataru; Matsuka, Yoshizo; Kuboki, Takuo

    2013-07-01

    This study aimed to compare the survival rates of remaining teeth between implant-supported fixed dentures (IFDs) and removable partial dentures (RPDs) in patients with large edentulous cases. The second goal was to assess the risk factors for remaining tooth loss. The study subjects were selected among those who received prosthodontic treatment at Okayama University Dental Hospital for their edentulous space exceeding at least four continuous missing teeth. Twenty-one patients were included in the IFD group and 82 patients were included in the RPD group. Survival rates of remaining teeth were calculated in three subcategories: (1) whole remaining teeth, (2) adjacent teeth to intended edentulous space, and (3) opposing teeth to intended edentulous space. The ten-year cumulative survival rate of the whole remaining teeth was significantly higher in the IFD group (40.0%) than in the RPD group (24.4%). On the other hand, there was no significant difference between two groups in the survival rate of teeth adjacent or opposing to intended edentulous space. A Cox proportional hazard analysis revealed that RPD restoration and gender (male) were the significant risk factors for remaining tooth loss (whole remaining teeth). These results suggest that IFD treatment can reduce the incidence of remaining tooth loss in large edentulous cases. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  10. Implant Supported Distal Extension over Denture Retained by Two Types of Attachments. A Comparative Radiographic Study by Cone Beam Computed Tomography

    Mahrous, Ahmed I; Aldawash, Hussien A; Soliman, Tarek A; Banasr, Fahad H; Abdelwahed, Ahmed

    2015-01-01

    Background: This study was conducted to compare and evaluate the effect of two different attachments (locator attachment and ball and socket [B&S] attachment) on implants and natural abutments supporting structures, in cases of limited inter-arch spaces in mandibular Kennedy Class I implant supported removable partial over dentures by measuring the bone height changes through the cone beam radiographic technology. Materials and Methods: Two implants were positioned in the first or second molar area following the two-stage surgical protocol. Two equal groups were divided ten for each: Group I: Sides were the placed implants restored by the locator attachment. Group II: The other sides, implants were restored by B&S attachment. Evaluation of the implants and main abutments supporting structures of each group was done at the time of removable partial over denture insertion, 6, 12 and 18 months by measuring the bone height changes using cone beam computed tomography. Results: Implants with locator attachment showed marginal bone height better effects on implants and main abutments supporting structures. Conclusion: Implants restored by locator attachment shows better effects on bone of both main natural abutments and implant than those restored with ball and socket. PMID:26028894

  11. Clinical experiences of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw: a 5-year follow-up study.

    Ortorp, A; Jemt, T

    1999-01-01

    Titanium frameworks have been used in the endentulous implant patient for the last 10 years. However, knowledge of titanium frameworks for the partially dentate patient is limited. To report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw. A consecutive group of 383 partially edentulous patients were, on a routine basis, provided with fixed partial prostheses supported by Brånemark implants in the mandible or maxilla. Besides conventional frameworks in cast gold alloy, 58 patients were provided with titanium frameworks with three different veneering techniques, and clinical and radiographic 5-year data were collected for this group. The overall cumulative survival rate was 95.6% for titanium-framework prostheses and 93.6% for implants. Average bone loss during the follow-up period was 0.4 mm. The most common complications were minor veneering fractures. Loose and fractured implant screw components were fewer than 2%. An observation was that patients on medications for cardiovascular problems may lose more implants than others (p laser-welded titanium frameworks was similar to that reported for conventional cast frames in partially edentulous jaws. Low-fusing porcelain veneers also showed clinical performance comparable to that reported for conventional porcelain-fused-to-metal techniques.

  12. Importance of a distal proximal contact on load transfer by implant-supported single adjacent crowns in posterior region of the mandible: a photoelastic study

    Fabio Afranio de Aguiar Junior

    2013-09-01

    Full Text Available OBJECTIVE: This study aimed to evaluate the importance of a distal proximal contact on the load transfer to the posterior region of the mandible by non-splinted adjacent implant-supported crowns using photoelastic stress analysis. MATERIAL AND METHODS: A rectangular model (68x30x15 mm was made of polymethylmethacrylate resin to simulate half of the mandibular arch. One model was completed with resin replicas representing the first premolar and second molar and with two 3.75 mm dia.x11 mm internal hexagon threaded implants replacing the second premolar and first molar. The other model was manufactured in the same way but without the second molar. Both models were duplicated using photoelastic resin. The roots of the teeth replicas were covered with a layer of polyether impression material to simulate the periodontal ligament. Two different vertical loads were applied to the crowns as follows: 1 - single static point load alternately applied to the crowns replacing the second premolar and first molar (50 N; 2 - simultaneous static point loads applied to both of the crowns replacing the second premolar and first molar (100 N. The resulting isochromatic fringe pattern in the photoelastic model was monitored and photographed. RESULTS: All loading conditions studied showed that the presence of the second molar has changed the load transmission and the pattern of stresses. CONCLUSION: Results showed that the presence of a second molar proximal contact can help minimize the stresses around the implants.

  13. Implant Supported Prosthesıs in a Patıent wıth Progerıa: Case Report

    Gözlem Ceylan

    2009-08-01

    Full Text Available Prosthodontic rehabilitation can be accomplished with fixed, overdenture, complete, or implant-retained prostheses. Dental treatment overcomes the patient’s functional, psychological, esthetic and phonation problems. Remaining healthy teeth may allow the dentist to fabrícate a removable partial overdenture, fixed partial prosthesis or implant - supported prosthesis. The retention of a number of abutments helps maintain a positive ridge form with greater height and volume of the alveolar bone, improving masticatory performance, as well as providing a more stable prostheses. Dental patients who have medical problems need many treatment procedures. Multidisciplinary treatment planning is invaluable for patient’s dental health. Progeria is a rare genetic condition where symptoms resembling aspects of aging are manifested at an early age. characteristic clinical findings of Progeria disease include abnormalities of the skin and hair in conjunction with char-acteristic facial features and skeletal abnormalities. The characteristic facies show protruding ears, beaked nose, thin lips with centrofacial cyanosis, prominent eyes, frontal and parietal bossing with pseudohydrocephaly, midface hypoplasia with micrognathia and large anterior fontanel. The other reported anomalies are dystrophic nails, hypertrophic scars and hypoplastic nipples. The findings that are nearly interested in dentistry are delayed dentition, anodontia, hypodontia, or crowding of teeth. This article presents the multidisciplinary dental treatment planning includes surgical, endodontic and prosthetic treatment of a patient with a history of progeria. In this case complete-arch fixed prostheses in both maxilla and mandible, supported by a combination of im-plants and teeth are reported.

  14. A 3-year prospective clinical study of telescopic crown, bar, and locator attachments for removable four implant-supported maxillary overdentures.

    Zou, Duohong; Wu, Yiqun; Huang, Wei; Wang, Feng; Wang, Shen; Zhang, Zhiyong; Zhang, Zhiyuan

    2013-01-01

    To evaluate telescopic crown (TC), bar, and locator attachments used in removable four implant-supported overdentures for patients with edentulous maxillae. A total of 30 maxillary edentulous patients were enrolled in a 3-year prospective study. Ten patients (group A) were treated with overdentures supported by TCs, 10 patients (group B) with overdentures supported by bar attachments, and 10 patients (group C) with overdentures supported by locator attachments. A total of 120 implants were used to restore oral function. During the 3-year follow-up period, implant survival and success rates, biologic and mechanical complications, prosthodontic maintenance efforts, and patient satisfaction were evaluated. All 30 patients were available for the 3-year follow-up and exhibited 100% implant survival and success rates. Peri-implant marginal bone resorption was not statistically significant for the three groups. There were lower plaque, bleeding, gingiva, and calculus indices in group C compared with groups A and B. The number of prosthodontic maintenance visits revealed eight complications in the TC group, seven complications in the bar group, and four complications in the locator group. However, there were no differences in the clinical effects of the overdentures in the three groups. Within the limits of this prospective study, it was concluded that the locator system produced superior clinical results compared with the TC and bar attachments in terms of peri-implant hygiene parameters, the frequency of prosthodontic maintenance measures, cost, and ease of denture preparation. However, longer-term prospective studies are required to confirm these results.

  15. Presenting a Multi-level Superstructure Optimization Approach for Mechatronic System Design

    Pedersen, Henrik C.; Andersen, Torben Ole; Bech, Michael Møller

    2010-01-01

    Synergism and integration in the design process is what sets apart a Mechatronic System from a traditional, multidisciplinary system. However the typical design approach has been to divide the design problem into sub problems for each technology area (mechanics, electronics and control) and descr......Synergism and integration in the design process is what sets apart a Mechatronic System from a traditional, multidisciplinary system. However the typical design approach has been to divide the design problem into sub problems for each technology area (mechanics, electronics and control......) and describe the interface between the technologies, whereas the lack of well-established, systematic engineering methods to form the basic set-off in analysis and design of complete mechatronic systems has been obvious. The focus of the current paper is therefore to present an integrated design approach...... for mechatronic system design, utilizing a multi-level superstructure optimization based approach. Finally two design examples are presented and the possibilities and limitations of the approach are outlined....

  16. Solution Construction of Multigeometry Nanoparticles and Multicompartment Superstructures from Block Copolymer Mixtures

    Zhu, Jiahua; Zhang, Shiyi; Wooley, Karen; Pochan, Darrin

    2013-03-01

    Novel soft objects with both compositional and geometric complexity at nanoscale have been constructed through solution supramolecular assembly from block copolymer mixtures due to their non-ergodic character. The mixture is composed of two block copolymers with distinctive hydrophobic blocks but the same poly(acrylic acid) hydrophilic block. First, multigeometry nanoparticles, due to segregation of unlike block copolymer molecules into multiple subdomains trapped within the same micelle-like structures, have been assembled in tetrahydrofuran/water solution. Through carefully designed molecular architecture, mixing ratio and pathway kinetics, both size and shape of subdomains can be controlled to produce a novel class of multigeometry nanoparticles, including sphere-sphere, sphere-cylinder, cylinder-cylinder, cylinder-disk, and sphere-disk hybrid nanoparticles. Second, hierarchical multicompartment superstructures including particle chains, rings and other nano to micro cluster formations, have been built up from pre-formed multigeometry nanoparticles by taking advantage of their surface anisotropy and the controlled particle-particle association. The interparticle association can be achieved via either covalent or non-covalent bindings due to different post-polymerization chemical modifications with hydroxyethyl acrylate or crown ether functionalities, respectively.

  17. Implant-supported auricular prosthesis

    Aditi Nanda

    2011-01-01

    Full Text Available Differences in the balance of shape, size, and position of body organs are immediately perceived as "looking wrong" and this perception can subject the individual to significant peer ridicule and social ostracism, often expressing as intense shame and anguish in the attitude of the afflicted. Rehabilitation of such patients can be remarkably beneficial on the individual′s self-esteem and body image. The onus of the deed lies in the hands of a team that combines artistic excellence with surgical expertise, by combining the skills of anaplastologists, surgeons, and prosthodontists. This is a review of a few surgical and prosthetic considerations in the management of auricular defect and a case description of management of a patient of microtia following similar guidelines in fabrication of the epithesis.

  18. Bone-repair properties of biodegradable hydroxyapatite nano-rod superstructures

    D'Elía, Noelia L.; Mathieu, Colleen; Hoemann, Caroline D.; Laiuppa, Juan A.; Santillán, Graciela E.; Messina, Paula V.

    2015-11-01

    Nano-hydroxyapatite (nano-HAp) materials show an analogous chemical composition to the biogenic mineral components of calcified tissues and depending on their topography they may mimic the specific arrangement of the crystals in bone. In this work, we have evaluated the potential of four synthesized nano-HAp superstructures for the in vitro conditions of bone-repair. Experiments are underway to investigate the effects of the material microstructure, surface roughness and hydrophilicity on their osseo-integration, osteo-conduction and osteo-induction abilities. Materials were tested in the presence of both, rat primary osteoblasts and rabbit mesenchymal stem cells. The following aspects are discussed: (i) cytotoxicity and material degradation; (ii) rat osteoblast spreading, proliferation and differentiation; and (iii) rabbit mesenchymal stem cell adhesion on nano-HAp and nano-HAp/collagen type I coatings. We effectively prepared a material based on biomimetic HAp nano-rods displaying the appropriate surface topography, hydrophilicity and degradation properties to induce the in vitro desired cellular responses for bone bonding and healing. Cells seeded on the selected material readily attached, proliferated and differentiated, as confirmed by cell viability, mitochondrial metabolic activity, alkaline phosphatase (ALP) activity and cytoskeletal integrity analysis by immunofluorescence localization of alpha-smooth muscle actin (α-SMA) protein. These results highlight the influence of material's surface characteristics to determine their tissue regeneration potential and their future use in engineering osteogenic scaffolds for orthopedic implants.Nano-hydroxyapatite (nano-HAp) materials show an analogous chemical composition to the biogenic mineral components of calcified tissues and depending on their topography they may mimic the specific arrangement of the crystals in bone. In this work, we have evaluated the potential of four synthesized nano-HAp superstructures

  19. Base, Superstructure and the Irish Property Crash—Towards a Crisis Theory of Communications

    Henry Silke

    2015-09-01

    Full Text Available Since the onset of the “great recession” there have been key debates around various aspects of crisis theory, most notably around the areas of the rate of profit (Brenner 2009; Kliman 2012, under-consumption/overproduction (Clarke 1990a, 442–467 and fiancialisation (Duménil and Lévy 2004. This paper maintains that communications and the media are key though non-deterministic elements of the contemporary market system, and proposes a move towards a crisis theory of communications. This research reflects the Marxist concept of base and superstructure, beyond a perceived notion of economic determinism, but rather as a dialectical relationship between various superstructures, in this case the state and the media, and the economic base including the various aspects of class power inherent within. The mass media, advertising, and ICT play an increasingly important role in both market systems and capitalist crises. This role directly impinges on the dissemination of information to market actors as well as the reflexive and dialectical nature of the processes by which actors respond to market information. Further, the media serve as an ideological apparatus, resource or arena, which acts to naturalise the market through what this research describes as a market orientated framing mechanism (Preston and Silke 2011b. Peter Thompson (2003; 2013, 208–227 contends that communication is an integral and reflexive part of the contemporary market system. As he puts it, there is a complex relationship between the producers and distributors of economic information, and those who use that information to make decisions about investment and trade. Many studies point to the convergence of flows of information such as those on 24-hour news channels, business channels and Internet blogs and sites with market activity itself. For Wayne Hope, (2010, 649–669 information broadcast on such media by bankers, stockbrokers and traders themselves tends to be self

  20. Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

    Safari, Sina; Hosseini Ghavam, Fereshteh; Amini, Parviz; Yaghmaei, Kaveh

    2018-02-01

    The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (α=.05). The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly ( P =.006). The difference in retention between the cemented and recemented copings was not statistically significant ( P =.40). Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement.

  1. Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

    Safari, Sina; Amini, Parviz; Yaghmaei, Kaveh

    2018-01-01

    PURPOSE The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (α=.05). RESULTS The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly (P=.006). The difference in retention between the cemented and recemented copings was not statistically significant (P=.40). CONCLUSION Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement. PMID:29503708

  2. Oral health related quality-of-life outcomes of partially edentulous patients treated with implant-supported single crowns or fixed partial dentures.

    AlZarea, Bader K

    2017-05-01

    Oral health-related quality of life (OHRQoL) is afflicted by different variables. Limited information is available regarding the impact of different phases of implant therapy on OHRQoL of edentulous patients. This study was carried out to assess the OHRQoL of patients treated with implant-supported single crowns or fixed partial dentures. A total of 79 healthy partially edentulous subjects needing implant therapy were incorporated in this study. Before placement of the implants, the subjects were instructed to fill the original version of OHIP questionnaire. Subsequently patients received titanium oral implants of the ITI® Dental Implant System. After 1st, 2nd and 3rd year of implant placement, patients filled the same OHIP-49 questionnaire. In this manner the impact of implant therapy on OHRQoL by putting in comparison pre- and post-treatment OHIP-49 scores was assessed. Statistical analyses were performed using Statistical Package for the Social Science software (SPSS, version 22, Chicago, IL, USA). Paired t test and Unpaired t test were performed and a statistical significance was set at 5% level of significance ( p disability, psychological disability, social disability were significantly decreased from baseline to 1st year ( p 0.05). All variables were also significantly decreased from baseline to 2nd year and 3rd year ( p 0.05). Patients aged less than 60 years and more than 60 years of age groups differed significantly with respect to OHIP scores measured at 1st year, 2nd year and at 3rd year of implant placement ( p Oral health-related quality-of-life.

  3. DEMOLISHING A COLD-WAR-ERA FULE-STORAGE BASIN SUPERSTRUCTURE LADEN WITH ASBESTOS

    LLOYD, E.R.; STEVENS, J.M.; DAGAN, E.B.; ORGILL, T.K.; GREEN, M.A.; LARSON, C.H.; ZINSLI, L.C.

    2009-01-01

    The K East (KE) Basin facilities are located near the north end of the Hanford Site's 100 K area. The facilities were built in 1950 as part of the KE Reactor complex and constructed within 400 meters of the Columbia River, which is the largest river in the Pacific Northwest and by volume the fourth largest river in the United States. The basin, located adjacent to the reactor, was used for the underwater storage of irradiated nuclear fuel discharged from the reactor. The basin was covered by a superstructure comprising steel columns and beams, concrete, and cement asbestos board (CAB) siding. The project's mission was to complete demolition of the structure over the KE Basin within six months of turnover from facility deactivation activities. The demolition project team applied open-air demolition techniques to bring the facility to slab-on-grade. Several innovative techniques were used to control contamination and maintain contamination control within the confines of the demolition exclusion zone. The techniques, which focused on a defense-in-depth approach, included spraying fixatives on interior and exterior surfaces before demolition began; applying fixatives during the demolition; misting using a fine spray of water during demolition; and demolishing the facility systematically. Another innovative approach that made demolition easier was to demolish the building with the non-friable CAB remaining in place. The CAB siding covered the exterior of the building and portions of the interior walls, and was an integral part of the multiple-layered roof. The project evaluated the risks involved in removing the CAB material in a radiologically contaminated environment and determined that radiological dose rates and exposure to radiological contamination and industrial hazards would be significantly reduced by using heavy equipment to remove the CAB during demolition. The ability to perform this demolition safely and without spreading contamination (radiological or

  4. The importance of DNA superstructure units for the understanding of the radiation action mechanism

    Regel, K.

    1985-04-01

    A molecular radiation action model is presented. It relates the physical parameters of the radiation interaction in tissue and of the DNA structure in mammalian cells to their dose survival curves. Using this model it is possible to explain many of the radiation effects in cells, including such ones which were not clearly understood as yet. Both the kind of the basic parameters and the 'efficiency' of the model suggest that it describes real properties of mammalian cells. However, in finding out the radiation action mechanism we had to fill up two gaps in our knowledge concerning the radiation action in organisms. The first gap is characterized by the question: Are there any DNA structures (sites) in mammalian cells on the basis of which a radiation action model can be established which is valid in all the cell cycle stages. This question is answered by comparisons of the magnitude of DNA parameters measured in suitable experiments with those calculated from a hypothetical model of DNA organization in mammalian cells. The second gap in knowledge is filled up by testing the hypothesis that certain patterns of double-strand breaks (DSBs) in the membrane attached superstructure units (MASSUs) of a cell cause its inactivation. The dependence of the dose survival curves on the cell cycle can be explained in the following way: Dose survival curves of G1, G2 and mitotic cells are changed because of the cyclically altering volume of the MASSU compartments. Its change during the S stage is mainly determined by the growing fraction of replicated MASSUs. The high radiation resistance of late S cells probably results from the ability of mammalian cells to establish one intact sister genome from both sister genomes containing heavily damaged MASSUs joint in the attachment points. This ability is explained by the interference of DSB repair, sister chromatid exchange and DNA degradation. (author)

  5. Prosthetic rehabilitation with an implant-supported fixed prosthesis using computer-aided design and computer-aided manufacturing dental technology for a patient with a mandibulectomy: A clinical report.

    Yoon, Hyung-In; Han, Jung-Suk

    2016-02-01

    The fabrication of dental prostheses with computer-aided design and computer-aided manufacturing shows acceptable marginal fits and favorable treatment outcomes. This clinical report describes the management of a patient who had undergone a mandibulectomy and received an implant-supported fixed prosthesis by using additive manufacturing for the framework and subtractive manufacturing for the monolithic zirconia restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Comparative Evaluation of a Four-Implant-Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design.

    Lee, Ki-Sun; Shin, Sang-Wan; Lee, Sang-Pyo; Kim, Jong-Eun; Kim, Jee-Hwan; Lee, Jeong-Yol

    The purpose of this pilot study was to evaluate and compare polyetherketoneketone (PEKK) with different framework materials for implant-supported prostheses by means of a three-dimensional finite element analysis (3D-FEA) based on cone beam computed tomography (CBCT) and computer-aided design (CAD) data. A geometric model that consisted of four maxillary implants supporting a prosthesis framework was constructed from CBCT and CAD data of a treated patient. Three different materials (zirconia, titanium, and PEKK) were selected, and their material properties were simulated using FEA software in the generated geometric model. In the PEKK framework (ie, low elastic modulus) group, the stress transferred to the implant and simulated adjacent tissue was reduced when compressive stress was dominant, but increased when tensile stress was dominant. This study suggests that the shock-absorbing effects of a resilient implant-supported framework are limited in some areas and that rigid framework material shows a favorable stress distribution and safety of overall components of the prosthesis.

  7. Esthetic and Clinical Performance of Implant-Supported All-Ceramic Crowns Made with Prefabricated or CAD/CAM Zirconia Abutments: A Randomized, Multicenter Clinical Trial.

    Wittneben, J G; Gavric, J; Belser, U C; Bornstein, M M; Joda, T; Chappuis, V; Sailer, I; Brägger, U

    2017-02-01

    Patients' esthetic expectations are increasing, and the options of the prosthetic pathways are currently evolving. The objective of this randomized multicenter clinical trial was to assess and compare the esthetic outcome and clinical performance of anterior maxillary all-ceramic implant crowns (ICs) based either on prefabricated zirconia abutments veneered with pressed ceramics or on CAD/CAM zirconia abutments veneered with hand buildup technique. The null hypothesis was that there is no statistically significant difference between the 2 groups. Forty implants were inserted in sites 14 to 24 (FDI) in 40 patients in 2 centers, the Universities of Bern and Geneva, Switzerland. After final impression, 20 patients were randomized into group A, restored with a 1-piece screw-retained single crown made of a prefabricated zirconia abutment with pressed ceramic as the veneering material using the cut-back technique, or group B using an individualized CAD/CAM zirconia abutment (CARES abutment; Institut Straumann AG) with a hand buildup technique. At baseline, 6 mo, and 1 y clinical, esthetic and radiographic parameters were assessed. Group A exhibited 1 dropout patient and 1 failure, resulting in a survival rate of 94.7% after 1 y, in comparison to 100% for group B. No other complications occurred. Clinical parameters presented stable and healthy peri-implant soft tissues. Overall, no or only minimal crestal bone changes were observed with a mean DIB (distance from the implant shoulder to the first bone-to-implant contact) of -0.15 mm (group A) and 0.12 mm (group B) at 1 y. There were no significant differences at baseline, 6 mo, and 1 y for DIB values between the 2 groups. Pink esthetic score (PES) and white esthetic score (WES) values at all 3 examinations indicated stability over time for both groups and pleasing esthetic outcomes. Both implant-supported prosthetic pathways represent a valuable treatment option for the restoration of single ICs in the anterior maxilla

  8. Precision Fit of Screw-Retained Implant-Supported Fixed Dental Prostheses Fabricated by CAD/CAM, Copy-Milling, and Conventional Methods.

    de França, Danilo Gonzaga; Morais, Maria Helena; das Neves, Flávio D; Carreiro, Adriana Fonte; Barbosa, Gustavo As

    The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses. Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium. Four zirconia frameworks were fabricated using the copy-milled system, and four were cast in cobalt-chromium using conventional casting with premachined abutments. The vertical and horizontal misfit at the implant-framework interface was measured using scanning electron microscopy at ×250. The results for vertical misfit were analyzed using Kruskal-Wallis and Mann-Whitney tests. The horizontal misfits were categorized as underextended, equally extended, or overextended. Statistical analysis established differences between groups according to the chi-square test (α = .05). The mean vertical misfit was 5.9 ± 3.6 μm for CAD/CAM-fabricated zirconia, 1.2 ± 2.2 μm for CAD/CAM-fabricated cobalt-chromium frameworks, 7.6 ± 9.2 μm for copy-milling-fabricated zirconia frameworks, and 11.8 (9.8) μm for conventionally fabricated frameworks. The Mann-Whitney test revealed significant differences between all but the zirconia-fabricated frameworks. A significant association was observed between the horizontal misfits and the fabrication method. The percentage of horizontal misfits that were underextended and overextended was higher in milled zirconia (83.3%), CAD/CAM cobaltchromium (66.7%), cast cobalt-chromium (58.3%), and CAD/CAM zirconia (33.3%) frameworks. CAD/CAM-fabricated frameworks exhibit better vertical misfit and low variability compared with copy-milled and conventionally fabricated frameworks. The percentage of interfaces equally extended was higher when CAD/CAM and zirconia were used.

  9. Effect of platform connection and abutment material on stress distribution in single anterior implant-supported restorations: a nonlinear 3-dimensional finite element analysis.

    Carvalho, Marco Aurélio; Sotto-Maior, Bruno Salles; Del Bel Cury, Altair Antoninha; Pessanha Henriques, Guilherme Elias

    2014-11-01

    Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections

  10. Ten-year survival and complication rates of lithium-disilicate (Empress 2) tooth-supported crowns, implant-supported crowns, and fixed dental prostheses.

    Teichmann, Maren; Göckler, Fabian; Weber, Volker; Yildirim, Murat; Wolfart, Stefan; Edelhoff, Daniel

    2017-01-01

    To prospectively evaluate the clinical long-term outcome of tooth-supported crowns (SCs), implant-supported crowns (ISCs), and fixed dental prostheses (FDPs) made of a lithium-disilicate glass-ceramic framework material (IPS Empress 2). Between 1997 and 1999, a total of 184 restorations (106 SCs, 32 ISCs, 33 FDPs, and 13 diverse restorations) were placed in 73 patients. Kaplan-Meier estimation was applied for survival and chipping-free rates. Inter-group comparison of both rates was realized by a log rank test and a 2×2 contingency table. Also, SCs and FDPs were compared regarding adhesive vs. conventional cementation, and anterior vs. posterior positioning, for impact on survival. Due to 14 dropouts (34 restorations) and reasonable exclusion of 19 other restorations, the final dataset included: i) 87 SCs [37 patients, mean observation time 11.4 (±3.8)years]; ii) 17 ISCs [12 patients, mean observation time 13.3 (±2.3)years; and iii) 27 FDPs [19 patients, mean observation time 8.9 (±5.4)years]. The 10-year survival rate/chipping-free rate for SCs were 86.1%/83.4%, for ISCs 93.8%/94.1%, and for FDPs were 51.9%/90.8%. Both ISCs and SCs had a significantly higher survival than FDPs (ISCs vs. FDPs: both tests p=0.001; SCs vs. FDPs: p=0.001 and p=0.005). Differences in the chipping-free rates did not reach significance. Also, neither the cementation mode nor positioning of the restoration had an impact on survival. SCs had a slightly lower outcome than can generally be expected from single crowns. In contrast, ICSs had a favorable outcome and the FDPs predominantly failed. The practitioner's choice of dental materials is based (at best) on long-term experience. The present 10-year results are based on comprehensive data analyses and show the high potential of lithium-disilicate as a reliable material, especially for single-unit restoration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Failure behavior of concrete pile and super-structure dynamic response as a result of soil liquefaction during earthquake

    Kaneda, Shogo; Hayashi, Kazuhiro; Hachimori, Wataru; Tamura, Shuji; Saito, Taiki

    2017-10-01

    In past earthquake disasters, numerous building structure piles were damaged by soil liquefaction occurring during the earthquake. Damage to these piles, because they are underground, is difficult to find. The authors aim to develop a monitoring method of pile damage based on superstructure dynamic response. This paper investigated the relationship between the damage of large cross section cementitious piles and the dynamic response of the super structure using a centrifuge test apparatus. A dynamic specimen used simple cross section pile models consisting of aluminum rod and mortar, a saturated soil (Toyoura sand) of a relative density of 40% and a super structure model of a natural period of 0.63sec. In the shaking table test under a 50G field (length scale of 1/50), excitation was a total of 3 motions scaled from the Rinkai wave at different amplitudes. The maximum acceleration of each of the excitations was 602gal, 336gal and 299gal. The centrifuge test demonstrated the liquefaction of saturated soil and the failure behavior of piles. In the test result, the damage of piles affected the predominant period of acceleration response spectrum on the footing of the superstructure.

  12. The monoclinic superstructure of the M2Pt6Al15 series (M=Ca, Sc, Y, La, Lu)

    Radzieowski, Mathis; Stegemann, Frank; Hoffmann, Rolf-Dieter; Janka, Oliver; Oldenburg Univ.

    2017-01-01

    The five ternary intermetallic compounds M 2 Pt 6 Al 15 (M=Ca, Sc, Y, La, Lu) were prepared from the elements by arc-melting. The crystal structure was determined via single crystal X-ray diffraction. The title compounds crystallize in a superstructure of the RE 0.67 Pt 2 Al 5 type structure (P6 3 /mmc) in the monoclinic crystal system with space group P12 1 /m1 (Sc 2 Pt 6 Al 15 : a=734.19(2), b=1628.96(10), c=734.19(2) pm, β=119.999(3) ; wR=0.0356, 3034 F 2 values, 68 variables). The superstructure can be derived by the superspace formalism using (3+2)D or (3+1)D interpretations of the diffraction data. The structural relation to the subcell structure is discussed on the basis of a group-subgroup scheme. In the crystal structure strongly bonded [Pt 2 Al 4 ] δ- slabs are alternatingly stacked with ordered layers containing M atoms and Al 3 triangles.

  13. Self-organization of nickel nanoparticles dispersed in acetone: From separate nanoparticles to three-dimensional superstructures

    I. Hernández-Pérez

    2017-02-01

    Full Text Available Sonochemical synthesis of monodisperse nickel nanoparticles (Ni-NPs by reduction of Ni acetylacetonate in the presence of polyvinylpyrrolidone stabilizer is reported. The Ni-NPs size is readily controlled to 5 nanometer diameter with a standard deviation of less than 5%. The as-prepared Ni-NPs sample was dispersed in acetone, for 4 weeks. For structural analysis was not applied to a magnetic field or heat treatment as key methods to direct the assembly. The transition from separate Ni-NPs into self-organization of three dimensions (3D superstructures was studied by electron microscopy. Experimental analysis suggests that the translation and rotation movement of the Ni-NPs are governed by magnetic frustration which promotes the formation of different geometric arrangements in two dimensions (2D. The formation of 3D superstructures is confirmed from scanning electron microscopy revealing a layered domain that consists of staking of several monolayers having multiple well-defined supercrystalline domains, enabling their use for optical, electronic and sensor applications.

  14. Analysis of connection element classes and locations and of some structural requirements for the mounting of different superstructure types on transport vehicles

    Zoran Đ. Majkić

    2011-04-01

    Full Text Available The paper presents the basic requirements for transport vehicles. A special request regarding the adaptation of transport vehicles for the transport of various types of cargo was taken into consideration. Superstructures and the situation arising after mounting superstructures on wheeled transport vehicles were analyzed and the following was described: console coupling, stirrups, simplex elastic coupling, two-way elastic and rigid connection elements. Vehicle torsional elasticity is provided by a proper choice of the type of connection between the superstructure and the vehicle chassis. Applying the instructions of vehicle manufacturers for using appropriate connections between the truck superstructure and the vehicle chassis provides positive torsional elasticity of the vehicle. The paper gives the general recommendations of the Volvo, Mercedes and Renault transport vehicle producers for the use of particular connection types of locations as well as structural requirements for the mounting of concrete mixers, tippers and truck tanks on their vehicles. Introduction Achieving a high level of transport effectiveness depends on a number of factors. One of the most important ones is the possibility to increase the payload share in the gross vehicle weight. This share depends on the net vehicle weight, a method of coupling the truck superstructure with the chassis frame as well as on the truck superstructure construction. Realization of this requirement is of significant importance, particularly for large business systems since it results in the reduction of number of necessary vehicles, more economic fleet maintenance and the fleet capacity increase. It is also relatively easy to adapt the vehicle for the transportation of other loads, depending on user's current needs. The adaptation is correctly performed if manufacturer's recommendations are followed during the mounting of the superstructure on the chassis. This paper gives the analysis of the

  15. Ag on Ge(111): 2D x-ray structure analysis of the #sq root#3 x #sq root#3 superstructure

    Dornisch, D.; Moritz, W.; Schulz, H.

    1992-01-01

    We have studied the Ag/Ge(111) square-root 3 x square-root 3 superstructure by grazing-incidence X-ray diffraction. In our structural analysis we find striking similarities to the geometry of Au on Si(111). The Ag atoms form trimer clusters with an Ag-Ag distance of 2.94 +/- 0.04 angstrom...

  16. A novel high-temperature commensurate superstructure in a natural bariopyrochlore: A structural study by means of a multiphase crystal structure refinement

    Bindi, L.; Petříček, Václav; Withers, R. L.; Zoppi, M.; Bonazzi, P.

    2006-01-01

    Roč. 179, - (2006), s. 716-725 ISSN 0022-4596 R&D Projects: GA ČR(CZ) GA202/03/0430 Institutional research plan: CEZ:AV0Z10100521 Keywords : pyrochlore * superstructure * X-ray data * multiphase structure refinement * TEM study Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.107, year: 2006

  17. Optomagnetic Detection of MicroRNA Based on Duplex-Specific Nuclease-Assisted Target Recycling and Multilayer Core-Satellite Magnetic Superstructures

    Tian, Bo; Ma, Jing; Qiu, Zhen

    2017-01-01

    -efficiency, and potential for bioresponsive multiplexing. Herein, we demonstrate a sensitive and rapid miRNA detection method based on optomagnetic read-out, duplex-specific nuclease (DSN)-assisted target recycling, and the use of multilayer core-satellite magnetic superstructures. Triggered by the presence of target mi...

  18. A novel high-temperature commensurate superstructure in a natural bariopyrochlore: A structural study by means of a multiphase crystal structure refinement

    Bindi, L.; Petricek, V.; Withers, R.L.; Zoppi, M.; Bonazzi, P.

    2006-01-01

    Additional X-ray diffraction effects yielding an eightfold commensurate superstructure [a=20.974(5)A] of the ideal pyrochlore structure were observed after annealing at 873K of a thallium-doped bariopyrochlore single crystal. Electron diffraction indicated the coexistence of two cubic phases, the pyrochlore structure and a new F-centred, cubic phase. The superstructure was solved and refined in the space group F4-bar 3m. The two phases were combined together and refined as independently diffracting to R=0.0628. The resulting unit-cell content is (A,-bar ) 20 Nb 16 Ti 2 O 53 (Z=8), with A=Ba, Tl, Ce, Th. For some atomic positions of the superstructure, third- and fourth-order anharmonic ADP's were used to account for the specific density shape having a continuous character as typical for ionic conductors. There are three distinct clusters in the superstructure, leading to a new structure type no longer strictly of pyrochlore-structure type

  19. Rehabilitation of an edentulous cleft lip and palate patient with a soft palate defect using a bar-retained, implant-supported speech-aid prosthesis: a clinical report.

    Hakan Tuna, S; Pekkan, Gurel; Buyukgural, Bulent

    2009-01-01

    Prosthetic rehabilitation of an edentulous cleft lip and palate patient with a combined hard and soft palate defect is a great challenge, due to the lack of retention of the obturator prosthesis as a result of its weight and the inability to obtain a border seal. Dental implants improve the retention, stability, and occlusal function of prostheses when used in carefully selected cleft lip and palate cases. This clinical report presents an edentulous unilateral cleft lip and palate patient who has hard and soft palate defects and an atrophied maxilla, treated with an implant-supported speech-aid prosthesis.

  20. Topotactic epitaxy of SrTiO3 mesocrystal superstructures with anisotropic construction for efficient overall water splitting

    Zhang, Peng; Fujitsuka, Mamoru; Majima, Tetsuro; Ochi, Tomoya; Kobori, Yasuhiro; Tachikawa, Takashi

    2017-01-01

    The higher-order structures of semiconductor-based photocatalysts play crucial roles in their physicochemical properties for efficient light-to-energy conversion. A novel perovskite SrTiO 3 mesocrystal superstructure with well-defined orientation of assembled cubic nanocrystals was synthesized by topotactic epitaxy from TiO 2 mesocrystals through a facile hydrothermal treatment. The SrTiO 3 mesocrystal exhibits three times the efficiency for the hydrogen evolution of conventional disordered systems in alkaline aqueous solution. It also exhibits a high quantum yield of 6.7 % at 360 nm in overall water splitting and even good durability up to 1 day. Temporal and spatial spectroscopic observations revealed that the synergy of the efficient electron flow along the internal nanocube network and efficient collection at the larger external cubes produces remarkably long-lived charges for enhanced photocatalysis. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Topotactic epitaxy of SrTiO{sub 3} mesocrystal superstructures with anisotropic construction for efficient overall water splitting

    Zhang, Peng; Fujitsuka, Mamoru; Majima, Tetsuro [The Institute of Scientific and Industrial Research (SANKEN), Osaka University (Japan); Ochi, Tomoya [Department of Chemistry, Graduate School of Science, Kobe University (Japan); Kobori, Yasuhiro [Department of Chemistry, Graduate School of Science, Kobe University (Japan); Molecular Photoscience Research Center, Kobe University (Japan); Tachikawa, Takashi [Department of Chemistry, Graduate School of Science, Kobe University (Japan); Molecular Photoscience Research Center, Kobe University (Japan); PRESTO, Science and Technology Agency (JST), Saitama (Japan)

    2017-05-02

    The higher-order structures of semiconductor-based photocatalysts play crucial roles in their physicochemical properties for efficient light-to-energy conversion. A novel perovskite SrTiO{sub 3} mesocrystal superstructure with well-defined orientation of assembled cubic nanocrystals was synthesized by topotactic epitaxy from TiO{sub 2} mesocrystals through a facile hydrothermal treatment. The SrTiO{sub 3} mesocrystal exhibits three times the efficiency for the hydrogen evolution of conventional disordered systems in alkaline aqueous solution. It also exhibits a high quantum yield of 6.7 % at 360 nm in overall water splitting and even good durability up to 1 day. Temporal and spatial spectroscopic observations revealed that the synergy of the efficient electron flow along the internal nanocube network and efficient collection at the larger external cubes produces remarkably long-lived charges for enhanced photocatalysis. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. The effect of heat treatments applied to superstructure porcelain on the mechanical properties and microstructure of lithium disilicate glass ceramics.

    Özdemir, Hatice; Özdoğan, Alper

    2018-01-30

    The aim of this study was to investigate that heat treatments with different numbers applied to superstructure porcelain whether effects microstructure and mechanical properties of lithium disilicate ceramic (LDC). Eighty disc-shaped specimens were fabricated from IPS e.max Press. Specimens were fired at heating values of porcelain in different numbers and divided four groups (n=5). Initial Vickers hardness were measured and X-ray diffraction (XRD) analysis was performed. Different surface treatment were applied and then Vickers hardness, surface roughness and environmental scanning electron microscopy (ESEM) analysis were performed. Data were analyzed with Varyans analysis and Tukey HSD test (α=0.05). Initial hardness among groups was no significant different (p>0.05), but hardness and surface roughness after surface treatments were significant different (pmicrostructure of LDC. Increasing firing numbers and surface treatments effect the microstructure of LDC.

  3. Hierarchical assembly of inorganic nanostructure building blocks to octahedral superstructures-a true template-free self-assembly

    Kuchibhatla, Satyanarayana V N T; Karakoti, Ajay S; Seal, Sudipta

    2007-01-01

    A room temperature, template-free, wet chemical synthesis of ceria nanoparticles and their long term ageing characteristics are reported. High resolution transmission electron microscopy and UV-visible spectroscopy techniques are used to observe the variation in size, structure and oxidation state, respectively as a function of time. The morphology variation and the hierarchical assembly (octahedral superstructure) of nanostructures are imputed to the inherent structural aspects of cerium oxide. It is hypothesized that the 3-5 nm individual building blocks will undergo an intra-agglomerate re-orientation to attain the low energy configuration. This communication also emphasizes the need for long term ageing studies of nanomaterials in various solvents for multiple functionalities

  4. A volatile-solvent gas fiber sensor based on polyaniline film coated on superstructure fiber Bragg gratings

    Ai, L; Chen, T C; Su, W K; Mau, J C; Liu, W F

    2008-01-01

    A fiber sensor based on a polyaniline (PANI) film that is coated on the surface of an etched superstructure fiber grating to detect volatile solvent vapors is experimentally demonstrated. This sensing mechanism is based on the interaction of the testing gas with the polyaniline coating film, which changes the film index, resulting in a shift in the Bragg wavelength. The sensitivity of this sensor to ammonia (NH 3 ) gas is about 0.073 pm ppm −1 , which depends on the optical characteristics of the fiber grating, the diameter of the fiber cladding and the constituents of the sensing film. Methanol concentrations can also be measured using this sensing scheme. The sensitivity of this sensor must be improved to provide a simple, reliable, repeatable and non-destructive method for sensing various chemical gases. (technical design note)

  5. Superstructure of the superconductor BI2Sr2CaCu2O8 by high resolution electron microscopy

    Hewat, E.A.

    1988-01-01

    The superstructure of the high Tc superconducting oxide BI 2S r 2C aCu 2 0 8 has been studied by high resolution electron microscopy. Waves of distortion along the b-axis give an incommensurate superlattice slightly larger or smaller than 5√2a p (a p = perovskite unit cell). The building blocks along the b-axis are 4, 5 and 6 times √2a p /2. The incommensurate superlattice is composed of approximately periodic combinations of these building blocks. The symmetry of three major projections are P gm (or possibly P gg ), C mm and C mm for the ideal superlattice with b=5√ 2a p . These projections correspond to the space groups Pcnn and Pmnn respectively

  6. A bio-inspired N-doped porous carbon electrocatalyst with hierarchical superstructure for efficient oxygen reduction reaction

    Miao, Yue-E.; Yan, Jiajie; Ouyang, Yue; Lu, Hengyi; Lai, Feili; Wu, Yue; Liu, Tianxi

    2018-06-01

    The bio-inspired hierarchical "grape cluster" superstructure provides an effective integration of one-dimensional carbon nanofibers (CNF) with isolated carbonaceous nanoparticles into three-dimensional (3D) conductive frameworks for efficient electron and mass transfer. Herein, a 3D N-doped porous carbon electrocatalyst consisting of carbon nanofibers with grape-like N-doped hollow carbon particles (CNF@NC) has been prepared through a simple electrospinning strategy combined with in-situ growth and carbonization processes. Such a bio-inspired hierarchically organized conductive network largely facilitates both the mass diffusion and electron transfer during the oxygen reduction reactions (ORR). Therefore, the metal-free CNF@NC catalyst demonstrates superior catalytic activity with an absolute four-electron transfer mechanism, strong methanol tolerance and good long-term stability towards ORR in alkaline media.

  7. Tunable superstructure fiber Bragg grating with chirp-distribution modulation based on the effect of external stress.

    Huang, Yize; Li, Yi; Zhu, Huiqun; Tong, Guoxiang; Fang, Baoying; Li, Liu; Shen, Yujian; Zheng, Qiuxin; Liang, Qian; Yan, Meng; Wang, Feng; Qin, Yuan; Ding, Jie; Wang, Xiaohua

    2012-09-15

    We report an external stress modulation method for producing a superstructure fiber Bragg grating (FBG) with approximate cascaded resonant cavities composed of different index chirp distributions. The 15 mm uncoated apodized uniform-period FBG is pressed by the vertical stress from the upper 11 pieces of the pattern plate controlled by a piezoelectric ceramic actuator. The piece length is 1 mm, and the interval of the adjacent pieces is 0.4 mm. The reflectivity of the modulated FBG gradually shows six obvious multichannel 75%-85% reflection peaks with the increase of the vertical stress of each pattern-plate piece from 0 to 30 N. The channel spacing is steady at about 10 GHz for a C-band wavelength division multiplexing system.

  8. Diamondlike carbon coating as a galvanic corrosion barrier between dental implant abutments and nickel-chromium superstructures.

    Ozkomur, Ahmet; Erbil, Mehmet; Akova, Tolga

    2013-01-01

    The objectives of this study were to evaluate the galvanic corrosion behavior between titanium and nickel-chromium (Ni-Cr) alloy, to investigate the effect of diamondlike carbon (DLC) coating over titanium on galvanic corrosion behavior between titanium and Ni-Cr alloy, and to evaluate the effect of DLC coating over titanium abutments on the fit and integrity of prosthetic assemblies by scanning electron microcopy (SEM). Five Ni-Cr and 10 titanium disks with a diameter of 5 mm and thickness of 3 mm were prepared. DLC coating was applied to five titanium disks. Electrode samples were prepared, and open circuit potential measurements, galvanic current measurements over platinum electrodes, and potentiodynamic polarization tests were carried out. For the SEM evaluation, 20 Ni-Cr alloy and 10 gold alloy superstructures were cast and prepared over 30 abutments. DLC coating was applied to 10 of the abutments. Following the fixation of prosthetic assemblies, the samples were embedded in acrylic resin and cross sectioned longitudinally. Internal fit evaluations were carried out through examination of the SEM images. Titanium showed more noble and electrochemically stable properties than Ni-Cr alloy. DLC coating over the cathode electrode served as an insulating film layer over the surface and prevented galvanic coupling. Results of the SEM evaluations indicated that the DLC-coated and titanium abutments showed no statistically significant difference in fit. Hence, no adverse effects on the adaptation of prosthetic components were found with the application of DLC coating over abutment surfaces. DLC coating might serve as a galvanic corrosion barrier between titanium abutments and Ni-Cr superstructures.

  9. Synthesis, morphology and microstructure of pomegranate-like hematite (α-Fe2O3) superstructure with high coercivity

    Tadic, Marin; Citakovic, Nada; Panjan, Matjaz; Stanojevic, Boban; Markovic, Dragana; Jovanovic, Đorđe; Spasojevic, Vojislav

    2012-01-01

    Highlights: ► We found superior magnetic properties of the hematite (α-Fe 2 O 3 ). ► TEM and HRTEM images show a pomegranate-like superstructure. ► Magnetic measurements display high coercivity H C = 4350 Oe at the room temperature. - Abstract: We found novel and superior magnetic properties of the hematite (α-Fe 2 O 3 ) that originate from an internal microstructure of particles and strong inter-particle interactions between nanocrystal sub-units. The hematite particles were synthesized by thermal decomposition of iron (III) nitrate without any template or surfactant. The purity, size, crystallinity, morphology, microstructure and magnetic features of the as-prepared particles were characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), energy-dispersive X-ray spectroscopy (EDX), transmission electron microscopy (TEM), high resolution transmission electron microscopy (HRTEM), Raman spectroscopy (RS) and SQUID magnetometry. An XRD study reveals a pure phase of α-Fe 2 O 3 whereas TEM shows α-Fe 2 O 3 spheres with a diameter of about 150 nm. RS also shows high quality and purity of the sample. Moreover, TEM and HRTEM images show a pomegranate-like superstructure and evidence that the spherical particles are composed of individual well-crystallized nanoparticle sub-units (self-assembled nanoparticles) with a size of about 20 nm. Magnetic measurements display hysteretic behavior at the room temperature with remanent magnetization M r = 0.731 emu/g, saturation magnetization M S = 6.83 emu/g and coercivity H C = 4350 Oe, as well as the Morin transition at T M = 261 K. These results and comparison with those in the literature reveal that the sample has extremely high coercivity. The magnetic properties of the sample are discussed in relation to morphology, internal microstructure, surface effects and exchange and dipole–dipole interactions.

  10. A one-piece 3D printed flexure translation stage for open-source microscopy

    Sharkey, James P.; Foo, Darryl C. W.; Kabla, Alexandre; Baumberg, Jeremy J.; Bowman, Richard W.

    2016-02-01

    Open source hardware has the potential to revolutionise the way we build scientific instruments; with the advent of readily available 3D printers, mechanical designs can now be shared, improved, and replicated faster and more easily than ever before. However, printed parts are typically plastic and often perform poorly compared to traditionally machined mechanisms. We have overcome many of the limitations of 3D printed mechanisms by exploiting the compliance of the plastic to produce a monolithic 3D printed flexure translation stage, capable of sub-micron-scale motion over a range of 8 × 8 × 4 mm. This requires minimal post-print clean-up and can be automated with readily available stepper motors. The resulting plastic composite structure is very stiff and exhibits remarkably low drift, moving less than 20 μm over the course of a week, without temperature stabilisation. This enables us to construct a miniature microscope with excellent mechanical stability, perfect for time-lapse measurements in situ in an incubator or fume hood. The ease of manufacture lends itself to use in containment facilities where disposability is advantageous and to experiments requiring many microscopes in parallel. High performance mechanisms based on printed flexures need not be limited to microscopy, and we anticipate their use in other devices both within the laboratory and beyond.

  11. Design for Manufacturing – One-Piece, Fibre-Placed Composite Helicopter Tailboom

    Marsden, Catharine; Fews, Robert; Oldroyd, Paul; Yousefpour, AH

    2011-01-01

    Recurring cost has become a critical driver in the design of helicopter airframes, and although composite materials have become widely used in aircraft structures, the hand lay-up manufacturing process in many cases prevents these applications from being cost-effective. Automated manufacturing technologies promise not only reduced production costs but also higher quality, repeatable parts. The introduction of existing automated manufacturing techniques and technologies from industries such as the automotive sector into aerospace can be challenging due to the unique product characteristics as well as the stringent certification and quality control requirements of the industry. The aerospace industry is a low-volume, high value production environment where 'hand-made' products are produced by highly experienced and qualified trades-people. Both metallic and composite components are subjected to precise manufacturing control and documentation requirements. The introduction of automated manufacturing technologies must be done in such a way as to respect these often demanding constraints. The introduction of automation to industrialized processes impacts not only the way parts are produced, but also the way they are designed. Successful composite design and manufacturing automation in the aerospace industry requires the engineering designer and analyst to become increasingly involved in the manufacturing of the product, as machine limitations and producibility become increasingly important drivers for design. This paper presents an overview of a development project intended to evaluate the effectiveness and benefits of the automated fibre placement technology through the design, prototype build and testing of a composite tailboom. The discussion centres on the 'design for manufacturing' concept and provides a perspective on the project objectives, material and process selection and trade-offs, geometric and structural considerations, and component assembly and fastening.

  12. Deciphering RNA regulatory elements in trypanosomatids: one piece at a time or genome-wide?

    Gazestani, Vahid H; Lu, Zhiquan; Salavati, Reza

    2014-05-01

    Morphological and metabolic changes in the life cycle of Trypanosoma brucei are accomplished by precise regulation of hundreds of genes. In the absence of transcriptional control, RNA-binding proteins (RBPs) shape the structure of gene regulatory maps in this organism, but our knowledge about their target RNAs, binding sites, and mechanisms of action is far from complete. Although recent technological advances have revolutionized the RBP-based approaches, the main framework for the RNA regulatory element (RRE)-based approaches has not changed over the last two decades in T. brucei. In this Opinion, after highlighting the current challenges in RRE inference, we explain some genome-wide solutions that can significantly boost our current understanding about gene regulatory networks in T. brucei. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Hierarchical super-structure identified by polarized light microscopy, electron microscopy and nanoindentation: Implications for the limits of biological control over the growth mode of abalone sea shells

    Schneider Andreas S

    2012-09-01

    Full Text Available Abstract Background Mollusc shells are commonly investigated using high-resolution imaging techniques based on cryo-fixation. Less detailed information is available regarding the light-optical properties. Sea shells of Haliotis pulcherina were embedded for polishing in defined orientations in order to investigate the interface between prismatic calcite and nacreous aragonite by standard materialographic methods. A polished thin section of the interface was prepared with a defined thickness of 60 μm for quantitative birefringence analysis using polarized light and LC-PolScope microscopy. Scanning electron microscopy images were obtained for comparison. In order to study structural-mechanical relationships, nanoindentation experiments were performed. Results Incident light microscopy revealed a super-structure in semi-transparent regions of the polished cross-section under a defined angle. This super-structure is not visible in transmitted birefringence analysis due to the blurred polarization of small nacre platelets and numerous organic interfaces. The relative orientation and homogeneity of calcite prisms was directly identified, some of them with their optical axes exactly normal to the imaging plane. Co-oriented "prism colonies" were identified by polarized light analyses. The nacreous super-structure was also visualized by secondary electron imaging under defined angles. The domains of the super-structure were interpreted to consist of crystallographically aligned platelet stacks. Nanoindentation experiments showed that mechanical properties changed with the same periodicity as the domain size. Conclusions In this study, we have demonstrated that insights into the growth mechanisms of nacre can be obtained by conventional light-optical methods. For example, we observed super-structures formed by co-oriented nacre platelets as previously identified using X-ray Photo-electron Emission Microscopy (X-PEEM [Gilbert et al., Journal of the

  14. Nb2OsB2, with a new twofold superstructure of the U3Si2 type: Synthesis, crystal chemistry and chemical bonding

    Mbarki, Mohammed; Touzani, Rachid St.; Fokwa, Boniface P.T.

    2013-01-01

    The new ternary metal-rich boride, Nb 2 OsB 2 , was synthesized by arc-melting the elements in a water-cooled copper crucible under an argon atmosphere. The compound was characterized from single-crystal X-ray data and EDX measurements. It crystallizes as a new superstructure (space group P4/mnc, no. 128) of the tetragonal U 3 Si 2 -structure type with lattice parameters a=5.922(1) Å and c=6.879(2) Å. All of the B atoms are involved in B 2 dumbbells with B–B distances of 1.89(4) Å. Structure relaxation using VASP (Vienna ab intio Simulation Package) has confirmed the space group and the lattice parameters. According to electronic structure calculations (TB–LMTO–ASA), the homoatomic B–B interactions are optimized and very strong, but relatively strong heteroatomic Os–B, Nb–B and Nb–Os bonds are also found: These interactions, which together build a three-dimensional network, are mainly responsible for the structural stability of this new phase. The density of state at the Fermi level predicts metallic behavior, as expected, from this metal-rich boride. - Graphical abstract: Nb 2 OsB 2 is, to the best of our knowledge, the first fully characterized phase in the ternary Nb–Os–B system. It crystallizes (space group P4/mnc, 128) with a new twofold superstructure of the U 3 Si 2 structure type (space group P4/mbm, 127), and is therefore the first boride in this structure family crystallizing with a superstructure of the U 3 Si 2 structure type. We show that the distortions leading to this superstructure occurs mainly in the Nb-layer, which tries to accommodate the large osmium atoms. The consequence of this puckering is the building osmium dumbbells instead of chains along [001]. - Highlights: • First compound in the Nb–Os–B system. • New twofold superstructure of U 3 Si 2 structure type. • Puckering of Nb-layer responsible for superstructure occurrence. • Chemical bonding studied by density functional theory

  15. The Origin of the Superstructure in Bi2Sr2CaCu2O8+dgr as Revealed by Scanning Tunneling Microscopy.

    Kirk, M D; Nogami, J; Baski, A A; Mitzi, D B; Kapitulnik, A; Geballe, T H; Quate, C F

    1988-12-23

    Real-space images with atomic resolution of the BiO plane of Bi(2)Sr(2)CaCu(2)O(8+delta) were obtained with a scanning tunneling microscope. Single-crystal samples were cleaved and imaged under ultrahigh vacuum conditions at room temperature. The images clearly show the one-dimensional incommensurate superstructure along the b-axis that is common to this phase. High-resolution images show the position of the Bi atoms, revealing the structural nature of the superlattice. A missing row of Bi atoms occurs either every nine or ten atomic sites in both (110) directions, accounting for the measured incommensurate periodicity of the superstructure. A model is proposed that includes missing rows of atoms, as well as displacements of the atomic positions along both the a- and c-axis directions.

  16. The origin of the superstructure in Bi2Sr2CaCu2O(8+delta) as revealed by scanning tunneling microscopy

    Kirk, M. D.; Nogami, J.; Baski, A. A.; Mitzi, D. B.; Kapitulnik, A.

    1988-12-01

    Real-space images with atomic resolution of the BiO plane of Bi2Sr2CaCu2O(8+delta) were obtained with a scanning tunneling microscope. Single-crystal samples were cleaved and imaged under ultrahigh vacuum conditions at room temperature. The images clearly show the one-dimensional incommensurate superstructure along the b-axis that is common to this phase. High-resolution images show the position of the Bi atoms, revelaing the structural nature of the superlattice. A missing row of Bi atoms occurs either every nine or ten atomic sites in both 110-line directions, accounting for the measured incommensurate periodicity of the superstructure. A model is proposed that includes missing rows of atoms, as well as displacements of the atomic positions along both the a- and c-axis directions.

  17. Synthesis and superstructure of La sub(2/3) (Mg sub(1/2)W sub(1/2))O/sub 3/

    Torii, Y [Government Industrial Research Inst., Nagoya (Japan)

    1979-10-01

    A new perovskite La sub(2/3)(Mg sub(1/2)W sub(1/2))O/sub 3/ having an orthorhombic multiple-cell was synthesized. The lattice constants were a = 7.8157(5) A, b = 7.8344(6) A and c = 2 x 7.9067(6) A. The superstructure was found to be due to a NaCl-type ordering of B ions as well as an ordering of A-site vacancies.

  18. Giant reversible magnetocaloric effect in flower-like β-Co(OH){sub 2} hierarchical superstructures self-assembled by nanosheets

    Liu, Xianguo; Feng, Chao; Xiao, Feng; Jin, Chuangui; Xia, Ailin, E-mail: liuxianguohugh@gmail.com, E-mail: eeswor@polyu.edu.hk [Anhui Key Laboratory of Metal Materials and Processing, School of Materials Science and Engineering, Anhui University of Technology, Ma' anshan, PR (China); Or, Siu Wing [Department of Electrical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon (Hong Kong); Sun, Yuping [Center for Engineering Practice and Innovation Education, Anhui University of Technology, Ma' anshan, PR (China)

    2014-01-15

    A facile hydrothermal strategy is proposed to synthesize flower-like β- Co(OH){sub 2} hierarchical microspherical superstructures with a diameter of 0.5-1.5 µm, which are self-assembled by β - Co(OH){sub 2} nano sheets with the average thickness ranging between 20 and 40 nm. The magnetocaloric effect associated with magnetic phase transitions in Co(OH){sub 2} superstructures has been investigated. A sign change in the magnetocaloric effect is induced by a magnetic field, which is related to a filed-induced transition from the antiferromagnetic to the ferromagnetic state below the Néel temperature. The large reversible magnetic-entropy change –ΔS{sub m} (13.4 J/kg K at 15 K for a field change of 5 T) indicates that flower-like Co(OH){sub 2} superstructures is a potential candidate for application in magnetic refrigeration in the low-temperature range. (author)

  19. Misfit and microleakage of implant-supported crown copings obtained by laser sintering and casting techniques, luted with glass-ionomer, resin cements and acrylic/urethane-based agents.

    Castillo-Oyagüe, Raquel; Lynch, Christopher D; Turrión, Andrés S; López-Lozano, José F; Torres-Lagares, Daniel; Suárez-García, María-Jesús

    2013-01-01

    This study evaluated the marginal misfit and microleakage of cement-retained implant-supported crown copings. Single crown structures were constructed with: (1) laser-sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC) and (3) vacuum-cast Ni-Cr-Ti (CN). Samples of each alloy group were randomly luted in standard fashion onto machined titanium abutments using: (1) GC Fuji PLUS (FP); (2) Clearfil Esthetic Cement (CEC); (3) RelyX Unicem 2 Automix (RXU) and (4) DentoTemp (DT) (n=15 each). After 60 days of water ageing, vertical discrepancy was SEM-measured and cement microleakage was scored using a digital microscope. Misfit data were subjected to two-way ANOVA and Student-Newman-Keuls multiple comparisons tests. Kruskal-Wallis and Dunn's tests were run for microleakage analysis (α=0.05). Regardless of the cement type, LS samples exhibited the best fit, whilst CC and CN performed equally well. Despite the framework alloy and manufacturing technique, FP and DT provide comparably better fit and greater microleakage scores than did CEC and RXU, which showed no differences. DMLS of Co-Cr may be a reliable alternative to the casting of base metal alloys to obtain well-fitted implant-supported crowns, although all the groups tested were within the clinically acceptable range of vertical discrepancy. No strong correlations were found between misfit and microleakage. Notwithstanding the framework alloy, definitive resin-modified glass-ionomer (FP) and temporary acrylic/urethane-based (DT) cements demonstrated comparably better marginal fit and greater microleakage scores than did 10-methacryloxydecyl-dihydrogen phosphate-based (CEC) and self-adhesive (RXU) dual-cure resin agents. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Validation of the "Quality of Life related to function, aesthetics, socialization, and thoughts about health-behavioural habits (QoLFAST-10)" scale for wearers of implant-supported fixed partial dentures.

    Castillo-Oyagüe, Raquel; Perea, Carmen; Suárez-García, María-Jesús; Río, Jaime Del; Lynch, Christopher D; Preciado, Arelis

    2016-12-01

    To validate the 'Quality of Life related to function, aesthetics, socialization, and thoughts about health-behavioural habits (QoLFAST-10)' questionnaire for assessing the whole concept of oral health-related quality of life (OHRQoL) of implant-supported fixed partial denture (FPD) wearers. 107 patients were assigned to: Group 1 (HP; n=37): fixed-detachable hybrid prostheses (control); Group 2 (C-PD, n=35): cemented partial dentures; and Group 3 (S-PD, n=35): screwed partial dentures. Patients answered the QoLFAST-10 and the Oral Health Impact Profile (OHIP-14sp) scales. Information on global oral satisfaction, socio-demographic, prosthetic, and clinical data was gathered. The psychometric capacity of the QoLFAST-10 was investigated. The correlations between both indices were explored by the Spearman's rank test. The effect of the study variables on the OHRQoL was evaluated by descriptive and non-parametric probes (α=0.05). The QoLFAST-10 was reliable and valid for implant-supported FPD wearers, who attained comparable results regardless of the connection system being cement or screws. Both fixed partial groups demonstrated significantly better social, functional, and total satisfaction than did HP wearers with this index. All groups revealed similar aesthetic-related well-being and consciousness about the importance of health-behavioural habits. Several study variables modulated the QoLFAST-10 scores. Hybrid prostheses represent the least predictable treatment option, while cemented and screwed FPDs supplied equal OHRQoL as estimated by the QoLFAST-10 scale. The selection of cemented or screwed FPDs should mainly rely on clinical factors, since no differences in patient satisfaction may be expected between both types of implant rehabilitations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Topotactic Epitaxy of SrTiO3 Mesocrystal Superstructures with Anisotropic Construction for Efficient Overall Water Splitting.

    Zhang, Peng; Ochi, Tomoya; Fujitsuka, Mamoru; Kobori, Yasuhiro; Majima, Tetsuro; Tachikawa, Takashi

    2017-05-02

    The higher-order structures of semiconductor-based photocatalysts play crucial roles in their physicochemical properties for efficient light-to-energy conversion. A novel perovskite SrTiO 3 mesocrystal superstructure with well-defined orientation of assembled cubic nanocrystals was synthesized by topotactic epitaxy from TiO 2 mesocrystals through a facile hydrothermal treatment. The SrTiO 3 mesocrystal exhibits three times the efficiency for the hydrogen evolution of conventional disordered systems in alkaline aqueous solution. It also exhibits a high quantum yield of 6.7 % at 360 nm in overall water splitting and even good durability up to 1 day. Temporal and spatial spectroscopic observations revealed that the synergy of the efficient electron flow along the internal nanocube network and efficient collection at the larger external cubes produces remarkably long-lived charges for enhanced photocatalysis. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Yb{sub 6}Ir{sub 5}Ga{sub 7} - a MgZn{sub 2} superstructure

    Seidel, Stefan; Poettgen, Rainer [Institut fuer Anorganische und Analytische Chemie, Universitaet Muenster, Corrensstrasse 30, 48149, Muenster (Germany)

    2017-02-15

    The gallide Yb{sub 6}Ir{sub 5}Ga{sub 7} was synthesized by high-frequency melting of the elements in a sealed niobium ampoule. The structure was refined from single-crystal X-ray diffractometer data: Nb{sub 6.4}Ir{sub 4}Al{sub 7.6} type, P6{sub 3}/mcm, a = 930.4(1), c = 843.0(1) pm, wR{sub 2} = 0.0597, 379 F{sup 2} values and 22 variables. Yb{sub 6}Ir{sub 5}Ga{sub 7} adopts a superstructure of the MgZn{sub 2} Laves phase by a complete ordering of the iridium and gallium atoms on the zinc substructure, i.e. the network consists of ordered and condensed Ir{sub 3}Ga and IrGa{sub 3} tetrahedra with Ir-Ga distances ranging from 260 to 265 pm. The crystal chemical details and the underlying group-subgroup scheme are discussed. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Investigating the construction of open-quotes pyramidclose quotes super-structures to dispose of radioactive and hazardous waste

    Miller, D.J.

    1994-01-01

    The technical challenges involved in disposing of radioactive and hazardous waste using systems that rely on open-quotes natural barriersclose quotes have been underestimated. Technology has advanced dramatically in the areas of materials, science, and engineering. As a result, traditional approaches to waste disposal must be rethought, focusing instead on ways to apply new technology breakthroughs to waste disposal problems. This paper will discuss problems currently faced by waste disposal systems that rely on natural barriers for containment, propose a general design and approach for constructing pyramid super-structures to dispose of (and store) waste, and present the benefits of such a system. The originality of this paper is that it proposes the construction of fully retrievable waste disposal systems that capitalize on the unique geometric properties of a pyramid and rely on engineered barriers and preventive measurements for containment, rather than natural barriers. In addition, this paper offers a new perspective on waste disposal issues confronting many countries. The desired effect is that by challenging conventional thought, new ideas could be developed to help solve existing problems. This paper is of specific interest to: (1) Policy makers, decisionmakers, and managers because the paper discusses the root causes of problems facing waste disposal and possible solutions. (2) Regulators because the paper discusses reasons for relying more on engineered barriers and preventive measurements to achieve confidence and reliability in containment. (3) Design engineers the paper offers new concepts for engineered barriers. 21 refs., 2 figs., 2 tabs

  4. Proposal for the award of an industrial services contract for civil engineering superstructure and internal construction building work

    2001-01-01

    This document concerns the award of an Industrial Services contract for civil engineering superstructure and internal construction building work. Following a market survey carried out among 112 firms in fifteen Member States, a call for tenders (IT-2546/ST/Rev.) was sent on 12 April 2001 to eleven consortia, four consisting of four firms, three consisting of three firms and four consisting of two firms, in seven Member States. By the closing date, CERN had received tenders from eight consortia in six Member States. The Finance Committee is invited to agree to the negotiation of a contract with the consortium SPIE CITRA SUD-EST(FR)-ANTIRUST TECHNOLOGY (GR), the lowest bidder, for an initial period of three years from 1 January 2002 for an amount not exceeding 15 375 000 Swiss francs, not subject to revision. The contract will include options for two one-year extensions beyond the initial three-year period. The consortium has indicated the following distribution by country of the contract value covered by this ...

  5. Ga induced superstructures as templates for lattice matched hetroepitaxial growth of GaN on Si(111) substrate

    Kumar, Praveen; Kuyyalil, Jithesh; Shivaprasad, S. M.

    2010-01-01

    High quality GaN is grown by plasma assisted molecular beam epitaxy on Ga induced superstructural phases of Si(111)7x7. Three stable surface phases induced by Ga adsorption, viz., (1x1), (6.3x6.3), and (√3x√3)R30 deg., are employed as templates to grow epitaxial (0001) GaN thin films. GaN grown on Si(√3x√3)R30 deg. -Ga is found to be highly crystalline with intense (0002) x-ray diffraction and photoluminescence peaks with low full width at half maximum, low surface roughness, and stoichiometric surface composition. The high quality of these GaN films formed at a low temperature of 400 deg. C is explained by the integral (x2) lattice matching between the unit cell of GaN and the (√3x√3) phase. The experiments demonstrate a plausible approach of adsorbate induced surface modifications as templates for III-V hetroepitaxy on Si surfaces.

  6. A multi-period superstructure optimisation model for the optimal planning of China's power sector considering carbon dioxide mitigation

    Zhang Dongjie; Ma Linwei; Liu Pei; Zhang Lili; Li Zheng

    2012-01-01

    Power sector is the largest CO 2 emitter in China. To mitigate CO 2 emissions for the power sector is a tough task, which requires implementation of targeted carbon mitigation policies. There might be multiple forms for carbon mitigation policies and it is still unclear which one is the best for China. Applying a superstructure optimisation model for optimal planning of China's power sector built by the authors previously, which was based on real-life plants composition data of China's power sector in 2009, and could incorporate all possible actions of the power sector, including plants construction, decommission, and application of carbon capture and sequestration (CCS) on coal-fuelled plants, the implementation effects of three carbon mitigation policies were studied quantitatively, achieving a conclusion that the so-called “Surplus-Punishment and Deficit-Award” carbon tax policy is the best from the viewpoint of increasing CO 2 reduction effect and also reducing the accumulated total cost. Based on this conclusion, the corresponding relationships between CO 2 reduction objectives (including the accumulated total emissions reduction by the objective year and the annual emissions reduction in the objective year) were presented in detail. This work provides both directional and quantitative suggestions for China to make carbon mitigation policies in the future. - Highlights: ► We study the best form of carbon mitigation policy for China's power sector. ► We gain quantitative relationship between CO 2 reduction goal and carbon tax policy. ► The “Surplus-Punishment and Deficit-Award” carbon tax policy is the best. ► Nuclear and renewable power and CCS can help greatly reduce CO 2 emissions of the power sector. ► Longer objective period is preferred from the viewpoint of policy making.

  7. Efficient visible light photocatalytic NO{sub x} removal with cationic Ag clusters-grafted (BiO){sub 2}CO{sub 3} hierarchical superstructures

    Feng, Xin [Chongqing Key Laboratory of Catalysis and Functional Organic Molecules, College of Environment and Resources, Engineering Research Center for Waste Oil Recovery Technology and Equipment of Ministry of Education, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 40067 (China); Zhang, Wendong [Department of Scientific Research Management, Chongqing Normal University, Chongqing 401331 (China); Deng, Hua [State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Ni, Zilin [Department of Scientific Research Management, Chongqing Normal University, Chongqing 401331 (China); Dong, Fan, E-mail: dfctbu@126.com [Chongqing Key Laboratory of Catalysis and Functional Organic Molecules, College of Environment and Resources, Engineering Research Center for Waste Oil Recovery Technology and Equipment of Ministry of Education, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 40067 (China); Zhang, Yuxin, E-mail: zhangyuxin@cqu.edu.cn [College of Materials Science and Engineering, National Key Laboratory of Fundamental Science of Micro/Nano-Devices and System Technology, Chongqing University, Chongqing 400044 (China)

    2017-01-15

    Graphical abstract: The cationic Ag clusters-grafted (BiO){sub 2}CO{sub 3} hierarchical superstructures exhibits highly enhanced visible light photocatalytic air purification through an interfacial charge transfer process induced by Ag clusters. - Highlights: • Microstructural optimization and surface cluster-grafting were firstly combined. • Cationic Ag clusters were grafted on the surface of (BiO){sub 2}CO{sub 3} superstructures. • The Ag clusters-grafted BHS displayed enhanced visible light photocatalysis. • Direct interfacial charge transfer (IFCT) from BHS to Ag clusters was proposed. • The charge transfer process and the dominant reactive species were revealed. - Abstract: A facile method was developed to graft cationic Ag clusters on (BiO){sub 2}CO{sub 3} hierarchical superstructures (BHS) surface to improve their visible light activity. Significantly, the resultant Ag clusters-grafted BHS displayed a highly enhanced visible light photocatalytic performance for NOx removal due to the direct interfacial charge transfer (IFCT) from BHS to Ag clusters. The chemical and coordination state of the cationic Ag clusters was determined with the extended X-ray absorption fine structure (EXAFS) and a theoretical structure model was proposed for this unique Ag clusters. The charge transfer process and the dominant reactive species (·OH) were revealed on the basis of electron spin resonance (ESR) trapping. A new photocatalysis mechanism of Ag clusters-grafted BHS under visible light involving IFCT process was uncovered. In addition, the cationic Ag clusters-grafted BHS also demonstrated high photochemical and structural stability under repeated photocatalysis runs. The perspective of enhancing photocatalysis through combination of microstructural optimization and IFCT could provide a new avenue for the developing efficient visible light photocatalysts.

  8. Observation of Vacancies, Faults, and Superstructures in Ln5Mo2O12 (Ln = La, Y, and Lu) Compounds with Direct Mo-Mo Bonding.

    Colabello, Diane M; Sobalvarro, Elizabeth M; Sheckelton, John P; Neuefeind, Joerg C; McQueen, Tyrel M; Khalifah, Peter G

    2017-11-06

    Among oxide compounds with direct metal-metal bonding, the Y 5 Mo 2 O 12 (A 5 B 2 O 12 ) structural family of compounds has a particularly intriguing low-dimensional structure due to the presence of bioctahedral B 2 O 10 dimers arranged in one-dimensional edge-sharing chains along the direction of the metal-metal bonds. Furthermore, these compounds can have a local magnetic moment due to the noninteger oxidation state (+4.5) of the transition metal, in contrast to the conspicuous lack of a local moment that is commonly observed when oxide compounds with direct metal-metal bonding have integer oxidation states resulting from the lifting of orbital degeneracy typically induced by the metal-metal bonding. Although a monoclinic C2/m structure has been previously proposed for Ln 5 Mo 2 O 12 (Ln = La-Lu and Y) members of this family based on prior single crystal diffraction data, it is found that this structural model misses many important structural features. On the basis of synchrotron powder diffraction data, it is shown that the C2/m monoclinic unit cell represents a superstructure relative to a previously unrecognized orthorhombic Immm subcell and that the superstructure derives from the ordering of interchangeable Mo 2 O 10 and LaO 6 building blocks. The superstructure for this reason is typically highly faulted, as evidenced by the increased breadth of superstructure diffraction peaks associated with a coherence length of 1-2 nm in the c* direction. Finally, it is shown that oxygen vacancies can occur when Ln = La, producing an oxygen deficient stoichiometry of La 5 Mo 2 O 11.55 and an approximately 10-fold reduction in the number of unpaired electrons due to the reduction of the average Mo valence from +4.5 to +4.05, a result confirmed by magnetic susceptibility measurements. This represents the first observation of oxygen vacancies in this family of compounds and provides an important means of continuously tuning the magnetic interactions within the one

  9. Superstructure Ta2O5 mesocrystals derived from (NH4)2Ta2O3F6 mesocrystals with efficient photocatalytic activity.

    Yu, Xin; Li, Wei; Huang, Jian; Li, Zhonghua; Liu, Jiawen; Hu, PingAn

    2018-02-06

    Superstructured mesocrystalline Ta 2 O 5 nanosheets were successfully prepared from mesocrystalline (NH 4 ) 2 Ta 2 O 3 F 6 nanorods by the annealing method for the first time. The as-prepared mesocrystalline Ta 2 O 5 nanosheets in this work showed remarkable visible light absorption, mainly due to the formation of oxygen vacancy defects in the mesocrystalline Ta 2 O 5 nanosheets, which was also confirmed by XPS spectra, Raman spectra and EPR spectra. Besides, the mesocrystalline Ta 2 O 5 nanosheets showed a highly enhanced photocatalytic activity of 11 268.24 μmol g -1 h -1 , about 3.95 times that of commercial Ta 2 O 5 . Moreover, the specific surface area of the mesocrystalline Ta 2 O 5 -800 nanosheets was 16.34 m 2 g -1 , about 5.32 times that of the commercial Ta 2 O 5 (3.072 m 2 g -1 ). The valence band XPS spectra indicated a strong oxidizing ability of the mesocrystalline Ta 2 O 5 nanosheets in comparison to that of commercial Ta 2 O 5 . The formation of superstructured Ta 2 O 5 mesocrystals generated long lifetime carriers and effective conduction pathways, which greatly enhanced the photocatalytic activity for hydrogen production.

  10. The monoclinic superstructure of the M{sub 2}Pt{sub 6}Al{sub 15} series (M=Ca, Sc, Y, La, Lu)

    Radzieowski, Mathis; Stegemann, Frank; Hoffmann, Rolf-Dieter [Muenster Univ. (Germany). Inst. fuer Anorganische und Analytische Chemie; Janka, Oliver [Muenster Univ. (Germany). Inst. fuer Anorganische und Analytische Chemie; Oldenburg Univ. (Germany). Inst. fuer Chemie

    2017-07-01

    The five ternary intermetallic compounds M{sub 2}Pt{sub 6}Al{sub 15} (M=Ca, Sc, Y, La, Lu) were prepared from the elements by arc-melting. The crystal structure was determined via single crystal X-ray diffraction. The title compounds crystallize in a superstructure of the RE{sub 0.67}Pt{sub 2}Al{sub 5} type structure (P6{sub 3}/mmc) in the monoclinic crystal system with space group P12{sub 1}/m1 (Sc{sub 2}Pt{sub 6}Al{sub 15}: a=734.19(2), b=1628.96(10), c=734.19(2) pm, β=119.999(3) ; wR=0.0356, 3034 F{sup 2} values, 68 variables). The superstructure can be derived by the superspace formalism using (3+2)D or (3+1)D interpretations of the diffraction data. The structural relation to the subcell structure is discussed on the basis of a group-subgroup scheme. In the crystal structure strongly bonded [Pt{sub 2}Al{sub 4}]{sup δ-} slabs are alternatingly stacked with ordered layers containing M atoms and Al{sub 3} triangles.

  11. Mini-implant-supported Molar Distalization

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  12. SrNi{sub 7.90(8)}In{sub 5.10(8)}. A new superstructure in the NaZn{sub 13} family

    Hoffmann, Rolf-Dieter; Poettgen, Rainer [Inst. fuer Anorganische und Analytische Chemie and NRW Graduate School of Chemistry, Univ. Muenster (Germany); Muts, Ihor [Inst. fuer Anorganische und Analytische Chemie and NRW Graduate School of Chemistry, Univ. Muenster (Germany); Inorganic Chemistry Dept., Ivan Franko National Univ., Lviv (Ukraine); Zaremba, Vasyl [Inorganic Chemistry Dept., Ivan Franko National Univ., Lviv (Ukraine)

    2009-07-01

    SrNi{sub 7.90(8)}In{sub 5.10(8)} was synthesized by induction melting of the elements in a sealed tantalum tube in a water-cooled silica sample chamber. The structure was refined on the basis of single crystal X-ray diffractometer data: Cccm, a = 1615.2(4), b = 1822.3(4), c = 1238.5(4) pm, wR2 = 0.1481, 4144F{sup 2} values and 150 variables. The striking structural motifs of the SrNi{sub 7.90}In{sub 5.10} structure are one-dimensional [Ni{sub 7} ] cluster units (242-286 pm Ni-Ni) which are surrounded by indium atoms. The structural relationship to the other NaZn{sub 13} superstructures is discussed on the basis of a group-subgroup scheme. (orig.)

  13. Application of a generic superstructure-based formulation to the design of wind-pumped-storage hybrid systems on remote islands

    Chen, Cheng-Liang; Chen, Hui-Chu; Lee, Jui-Yuan

    2016-01-01

    Highlights: • A rigorous model for hybrid power system (HPS) design to support a remote island. • Use pumped hydro storage to store tentative surplus electricity. • Formulate the HPS design problem as a mixed-integer linear program (MILP). - Abstract: This paper aims to present a mathematical model for the design of a hybrid power system (HPS) to support a remote island with 100 thousand citizens. The goal is to reduce diesel fuel consumption by adequate expansion of wind power supply. Pumped hydroelectric storage (PHS) is used in the HPS to buffer the impact of intermittent behavior of wind energy. A superstructure is proposed for HPS design, considering all possible capital decisions (e.g. the number of wind turbines) and hourly-basis operational variables (such as the amount of surplus electricity in storage and its discharge). The HPS design problem can then be formulated as a mixed-integer linear program (MILP) based on the proposed superstructure. For a given total share of wind power, the optimal mix of diesel-based and wind power supplies as well as the required capacity of PHS are determined using a four-step optimization approach, involving minimizing (i) the consumption of diesel fuel, (ii) the number of wind turbines, (iii) the size of the upper water reservoir, and (iv) the charge/discharge rates of the PHS system. In this sequential optimization, the objective value obtained in a previous step is added as an additional constraint to the next step. The proposed HPS design model is applied to a real case study of the remote K Island on the other side of Taiwan Strait using hourly-basis, year-round historical data. Inclusion of other renewable energy sources, such as photovoltaic cells and biomass-fired power plants, as well as economic perspectives will be considered in future work.

  14. Superstructure formation in PrNi{sub 2}Al{sub 3} and ErPd{sub 2}Al{sub 3}

    Eustermann, Fabian; Hoffmann, Rolf-Dieter [Muenster Univ. (Germany). Inst. fuer Anorganische und Analytische Chemie; Janka, Oliver [Muenster Univ. (Germany). Inst. fuer Anorganische und Analytische Chemie; Oldenburg Univ. (Germany). Inst. fuer Chemie

    2017-09-01

    The intermetallic phase ErPd{sub 2}Al{sub 3} was obtained by arc-melting of the elements and subsequent annealing for crystal growth. The sample was studied by X-ray diffraction on powders and single crystals. The structure of ErPd{sub 2}Al{sub 3} was refined from X-ray diffraction data and revealed a superstructure of PrNi{sub 2}Al{sub 3} - a CaCu{sub 5} derivative (P6/m, a=1414.3(1), c=418.87(3) pm wR=0.0820, 1060 F{sup 2} values, 48 variables). The same superstructure was subsequently found for PrNi{sub 2}Al{sub 3} (P6/m, a=1407.87(4), c=406.19(2) pm, wR=0.0499, 904 F{sup 2} values, 47 variables). In the crystal structure, the aluminium and transition metal atoms form a polyanionic network according to [T{sub 2}Al{sub 3}]{sup δ-}, while rare earth atoms fill cavities within the networks. They are coordinated by six transition metal and twelve aluminum atoms. In contrast to the PrNi{sub 2}Al{sub 3} type structure reported so far, two crystallographic independent rare-earth sites are found of which one (1b) is shifted by 1/2 z, causing a distortion in the structure along with a recoloring of the T and Al atoms in the network.

  15. Evaluation of the success rate of cone beam computed tomography in determining the location and direction of screw access holes in cement-retained implant-supported prostheses: An in vitro study.

    Neshandar Asli, Hamid; Dalili Kajan, Zahra; Gholizade, Fatemeh

    2018-02-21

    Cement-retained implant-supported restorations have advantages over screw-retained restorations but are difficult to retrieve. Identifying the approximate location of the screw access hole (SAH) may reduce damage to the prosthesis. The purpose of this in vitro study was to evaluate the ability of cone beam computed tomography (CBCT) imaging to determine the location and direction of SAHs in cement-retained implant prostheses. Five clear acrylic resin casts were made based on a mandibular model. Several implant osteotomies (n=30) were created on the models with surgical burs, and crowns were made using the standard laboratory method with a transfer coping and the closed tray impression technique. CBCT images from the acrylic resin casts were evaluated by a maxillofacial radiologist who was blind to the locations and angles of the osteotomies. The locations of the access holes were determined on multiplanar reconstruction images and transferred to the clinical crown surface as defined points. Based on cross-sectional images, the predicted angle of the access hole was provided to a prosthodontist who was requested to pierce the crown at the proposed location in the specified direction. If the location and/or direction of the access hole were found, the process was considered successful, as the crown could then be removed from the implant abutment through the SAH. The success rate in the detection of the location and direction of the SAH was calculated, and chi-square and Fisher exact tests were applied for data analysis (α=.05). According to the results of this study, the success rate of CBCT to define the location of SAHs was 83.3% and 80% to determine the direction. No significant differences were found among the different dental groups in determination of the location (P=.79) or the direction (P=.53) of the SAHs. Most of the failures in determining the location and direction of the access hole in the buccolingual and mesiodistal directions were in the buccal and

  16. Nb{sub 2}OsB{sub 2}, with a new twofold superstructure of the U{sub 3}Si{sub 2} type: Synthesis, crystal chemistry and chemical bonding

    Mbarki, Mohammed; Touzani, Rachid St.; Fokwa, Boniface P.T., E-mail: boniface.fokwa@ac.rwth-aachen.de

    2013-07-15

    The new ternary metal-rich boride, Nb{sub 2}OsB{sub 2}, was synthesized by arc-melting the elements in a water-cooled copper crucible under an argon atmosphere. The compound was characterized from single-crystal X-ray data and EDX measurements. It crystallizes as a new superstructure (space group P4/mnc, no. 128) of the tetragonal U{sub 3}Si{sub 2}-structure type with lattice parameters a=5.922(1) Å and c=6.879(2) Å. All of the B atoms are involved in B{sub 2} dumbbells with B–B distances of 1.89(4) Å. Structure relaxation using VASP (Vienna ab intio Simulation Package) has confirmed the space group and the lattice parameters. According to electronic structure calculations (TB–LMTO–ASA), the homoatomic B–B interactions are optimized and very strong, but relatively strong heteroatomic Os–B, Nb–B and Nb–Os bonds are also found: These interactions, which together build a three-dimensional network, are mainly responsible for the structural stability of this new phase. The density of state at the Fermi level predicts metallic behavior, as expected, from this metal-rich boride. - Graphical abstract: Nb{sub 2}OsB{sub 2} is, to the best of our knowledge, the first fully characterized phase in the ternary Nb–Os–B system. It crystallizes (space group P4/mnc, 128) with a new twofold superstructure of the U{sub 3}Si{sub 2} structure type (space group P4/mbm, 127), and is therefore the first boride in this structure family crystallizing with a superstructure of the U{sub 3}Si{sub 2} structure type. We show that the distortions leading to this superstructure occurs mainly in the Nb-layer, which tries to accommodate the large osmium atoms. The consequence of this puckering is the building osmium dumbbells instead of chains along [001]. - Highlights: • First compound in the Nb–Os–B system. • New twofold superstructure of U{sub 3}Si{sub 2} structure type. • Puckering of Nb-layer responsible for superstructure occurrence. • Chemical bonding studied

  17. Building a strategy for obesity prevention one piece at a time: the case of sugar-sweetened beverage taxation.

    Buhler, Susan; Raine, Kim D; Arango, Manuel; Pellerin, Suzie; Neary, Neil E

    2013-04-01

    Obesity is a major public health issue in Canada that is reaching historically high levels in spite of efforts, targeted primarily at individual behaviour, to promote changes in diet and physical activity. Urgency for change at the population level compels moving "upstream" toward multilevel, societal approaches for obesity prevention. Public health researchers, advocates and policy makers are increasingly recognizing the current food environment, including availability, pricing, and marketing of foods and beverages, promotes overconsumption of unhealthy food and beverage choices and have identified the food environment as a point for intervention for obesity prevention. In April 2011, a consensus conference with invited experts from research, policy and practice fields was held. The conference aimed to build consensus around policy levers to address environmental determinants of obesity, including next logical steps toward further policy action. Using economic policies, such as taxation of sugar-sweetened beverages (SSB), was discussed as one opportunity to promote healthy eating. This article reports on the consensus discussion that led to recommendations to tax sugar-sweetened beverages as one step in a multipronged comprehensive approach to obesity prevention. This recommendation is based on a synthesis of available evidence, including evidence regarding political feasibility, and potential impacts of a tax. In addition, we present additional primary research using current SSB consumption data to model the economic and behavioural impact of such a tax in Canada. Copyright © 2013 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  18. Implant Supported Fixed Restorations versus Implant Supported Removable Overdentures: A Systematic Review

    Selim, Khaled; Ali, Sherif; Reda, Ahmed

    2016-01-01

    AIM: The aim of this study is to systematically evaluate and compare implant retained fixed restoration versus implant retained over denture. MATERIAL AND METHODS: Search was made in 2 databases including PubMed and PubMed Central. Title and abstract were screened to select studies comparing implant retained fixed restorations versus implant retained removable overdentures. Articles which did not follow the inclusion criteria were excluded. Included papers were then read carefully for a second stage filter, this was followed by manual searching of bibliography of selected articles. RESULTS: The search resulted in 5 included papers. One study evaluated the masticatory function, while the other 4 evaluated the patient satisfaction. Two of them used Visual Analogue Scale (VAS) as a measurement tool, while the other two used VAS and Categorical Scales (CAT). Stability, ability to chew, ability to clean, ability to speak and esthetics were the main outcomes of the 4 included papers. CONCLUSION: Conflicting results was observed between the fixed and removable restorations. PMID:28028423

  19. Synthesis, morphology and microstructure of pomegranate-like hematite ({alpha}-Fe{sub 2}O{sub 3}) superstructure with high coercivity

    Tadic, Marin, E-mail: marint@vinca.rs [Condensed Matter Physics Laboratory, Vinca Institute, University of Belgrade, P.O. Box 522, 11001 Belgrade (Serbia); Citakovic, Nada [Military Academy, Generala Pavla Jurisica Sturma 33, University of Belgrade, 11000 Belgrade (Serbia); Panjan, Matjaz [Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Stanojevic, Boban [Vinca Institute of Nuclear Sciences, P.O. Box 522, 11001 Belgrade, University of Belgrade (Serbia); Markovic, Dragana [Condensed Matter Physics Laboratory, Vinca Institute, University of Belgrade, P.O. Box 522, 11001 Belgrade (Serbia); Jovanovic, Dorde [Center for Solid State Physics and New Materials, Institute of Physics, University of Belgrade, Pregrevica 118, 11080 Belgrade (Serbia); Spasojevic, Vojislav [Condensed Matter Physics Laboratory, Vinca Institute, University of Belgrade, P.O. Box 522, 11001 Belgrade (Serbia)

    2012-12-05

    Highlights: Black-Right-Pointing-Pointer We found superior magnetic properties of the hematite ({alpha}-Fe{sub 2}O{sub 3}). Black-Right-Pointing-Pointer TEM and HRTEM images show a pomegranate-like superstructure. Black-Right-Pointing-Pointer Magnetic measurements display high coercivity H{sub C} = 4350 Oe at the room temperature. - Abstract: We found novel and superior magnetic properties of the hematite ({alpha}-Fe{sub 2}O{sub 3}) that originate from an internal microstructure of particles and strong inter-particle interactions between nanocrystal sub-units. The hematite particles were synthesized by thermal decomposition of iron (III) nitrate without any template or surfactant. The purity, size, crystallinity, morphology, microstructure and magnetic features of the as-prepared particles were characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), energy-dispersive X-ray spectroscopy (EDX), transmission electron microscopy (TEM), high resolution transmission electron microscopy (HRTEM), Raman spectroscopy (RS) and SQUID magnetometry. An XRD study reveals a pure phase of {alpha}-Fe{sub 2}O{sub 3} whereas TEM shows {alpha}-Fe{sub 2}O{sub 3} spheres with a diameter of about 150 nm. RS also shows high quality and purity of the sample. Moreover, TEM and HRTEM images show a pomegranate-like superstructure and evidence that the spherical particles are composed of individual well-crystallized nanoparticle sub-units (self-assembled nanoparticles) with a size of about 20 nm. Magnetic measurements display hysteretic behavior at the room temperature with remanent magnetization M{sub r} = 0.731 emu/g, saturation magnetization M{sub S} = 6.83 emu/g and coercivity H{sub C} = 4350 Oe, as well as the Morin transition at T{sub M} = 261 K. These results and comparison with those in the literature reveal that the sample has extremely high coercivity. The magnetic properties of the sample are discussed in relation to morphology, internal microstructure, surface

  20. The line shape of the Ortho-II superstructure reflection in YBa2Cu3O6.5

    Schleger, P.; Hadfield, R.; Casalta, H.

    1994-01-01

    Neutron and synchrotron x-ray measurements of the Ortho-II superstructure reflections on a high quality single crystal of YBa2Cu3O6.5 revealed that the intrinsic line shape is a Lorentzian to the power 5/2. It is argued that such a line shape implies late-stage domain coarsening of a quenched...... system ordering in three dimensions (d=3) with a two component order parameter (n=2)....

  1. Nb2OsB2, with a new twofold superstructure of the U3Si2 type: Synthesis, crystal chemistry and chemical bonding

    Mbarki, Mohammed; Touzani, Rachid St.; Fokwa, Boniface P. T.

    2013-07-01

    The new ternary metal-rich boride, Nb2OsB2, was synthesized by arc-melting the elements in a water-cooled copper crucible under an argon atmosphere. The compound was characterized from single-crystal X-ray data and EDX measurements. It crystallizes as a new superstructure (space group P4/mnc, no. 128) of the tetragonal U3Si2-structure type with lattice parameters a=5.922(1) Å and c=6.879(2) Å. All of the B atoms are involved in B2 dumbbells with B-B distances of 1.89(4) Å. Structure relaxation using VASP (Vienna ab intio Simulation Package) has confirmed the space group and the lattice parameters. According to electronic structure calculations (TB-LMTO-ASA), the homoatomic B-B interactions are optimized and very strong, but relatively strong heteroatomic Os-B, Nb-B and Nb-Os bonds are also found: These interactions, which together build a three-dimensional network, are mainly responsible for the structural stability of this new phase. The density of state at the Fermi level predicts metallic behavior, as expected, from this metal-rich boride.

  2. Self-assembly of multiferroic core-shell particulate nanocomposites through DNA-DNA hybridization and magnetic field directed assembly of superstructures

    Sreenivasulu, Gollapudi; Srinivasan, Gopalan, E-mail: srinivas@oakland.edu, E-mail: chavez@oakland.edu [Department of Physics, Oakland University, Rochester, MI 48309-4401 (United States); Lochbiler, Thomas A.; Panda, Manashi; Chavez, Ferman A., E-mail: srinivas@oakland.edu, E-mail: chavez@oakland.edu [Department of Chemistry, Oakland University, Rochester, MI 48309-4401 (United States)

    2016-04-15

    Multiferroic composites of ferromagnetic and ferroelectric phases are of importance for studies on mechanical strain mediated coupling between the magnetic and electric subsystems. This work is on DNA-assisted self-assembly of superstructures of such composites with nanometer periodicity. The synthesis involved oligomeric DNA-functionalized ferroelectric and ferromagnetic nanoparticles, 600 nm BaTiO{sub 3} (BTO) and 200 nm NiFe{sub 2}O{sub 4} (NFO), respectively. Mixing BTO and NFO particles, possessing complementary DNA sequences, resulted in the formation of ordered core-shell heteronanocomposites held together by DNA hybridization. The composites were imaged by scanning electron microscopy and scanning microwave microscopy. The presence of heteroassemblies along with core-shell architecture is clearly observed. The reversible nature of the DNA hybridization allows for restructuring the composites into mm-long linear chains and 2D-arrays in the presence of a static magnetic field and ring-like structures in a rotating-magnetic field. Strong magneto-electric (ME) coupling in as-assembled composites is evident from static magnetic field H induced polarization and low-frequency magnetoelectric voltage coefficient measurements. Upon annealing the nanocomposites at high temperatures, evidence for the formation of bulk composites with excellent cross-coupling between the electric and magnetic subsystems is obtained by H-induced polarization and low-frequency ME voltage coefficient. The ME coupling strength in the self-assembled composites is measured to be much stronger than in bulk composites with randomly distributed NFO and BTO prepared by direct mixing and sintering.

  3. Características ultra-estruturais do nó sinoatrial de rato Wistar Superstructural features of the wistar strain male rats' sinoatrial node (SAN

    Carlos Alberto Mandarim de Lacerda

    2002-04-01

    Full Text Available As características ultra-estruturais do nó sinoatrial (NSA de 5 ratos machos da variedade Wistar, com 3 meses de idade, foram estudadas por meio de microscopia eletrônica de transmissão (MET. Fragmento pequeno, contendo a região do NSA e área adjacente do átrio direito do coração, foi retirado e fixado em glutaraldeído 2,5% e processado de acordo com técnica convencional para MET. A morfologia do nó sinoatrial de ratos é semelhante a de outros mamíferos. O NSA é uma estrutura anatômica independente do miocárdio atrial, constituído por células típicas (miócitos nodais, células de transição e, principalmente, células nodais imersos em matriz extracelular, na qual predominam fibras colágenas, fibroblastos e nervosThe superstructural features of five Wistar strain male rats' sinoatrial node (SAN at 3-mo-old were studied through transmission electron microscopy (TEM. Small fragments with the regions containing the SAN were cut off, fixed in glutaraldehyde 2.5% and processed according to the conventional technique for TEM. The morphology of the sinoatrial node of the rats is similar as found in other mammals. The SAN is an independent anatomic structure of the atrial myocardial, constituted of typical cells (nodal myocytes, transition cells and nodal cells principally immersed in the extra cellular matrix where collagen fibers, fibroblasts and nerve predominate

  4. Anomalous jump of stress upon the variation of the rate of deformation of single crystals of the Ni3Ge alloys with L12 superstructure under the conditions of cubic slip

    Starenchenko, V.A.; Solov'eva, Yu.V.; Gettinger, M.V.; Kovalevskaya, T.A.

    2005-01-01

    Experimental results are given on variations of plastic strain rate for Ni 3 Ge alloy with L1 2 superstructure possessing anomalous temperature dependence of mechanical properties. For the first time an anomalous strain rate dependence of mechanical properties of the alloy is revealed under conditions of cubic slip. The mechanism is proposed to explain the observed form of stress jump. Using the mechanism proposed normal and anomalous constituents of stress jump are separated. Temperature dependences of stress jump, normal and anomalous constituents of stress jump are analyzed [ru

  5. A new anion-deficient fluorite-related superstructure of Bi{sub 28}V{sub 8}O{sub 62}

    Đorđević, T., E-mail: tamara.djordjevic@univie.ac.at [Institut für Mineralogie und Kristallographie-Geozentrum, Universität Wien, Althansstr. 14, A-1090 Wien (Austria); Karanović, Lj., E-mail: ljika2002@yahoo.com [Laboratory for Crystallography, Faculty of Mining and Geology, University of Belgrade, Đušina 7, 11000 Belgrade (Serbia)

    2014-12-15

    New hydrothermally synthesized Bi{sub 28}V{sub 8}O{sub 62} was structurally characterized using single-crystal X-ray diffraction data. Bi{sub 28}V{sub 8}O{sub 62} crystallizes in the novel type of defect fluorite structure related to the face-centered cubic δ-Bi{sub 2}O{sub 3}. It is monoclinic, s. g. P2{sub 1}/c, and the relation to the fluorite subcell is given as a∼(3/2)a{sub F}+(3/2)c{sub F}; b∼ −b{sub F}; c∼2a{sub F} −4c{sub F} (F in subscript indicate the unit cell parameter of fluorite). Its structure is characterized by slabs of edge sharing OBi{sub 4} tetrahedra surrounded by the OBi{sub 3} triangles. As a part of these OBi{sub 3} triangles, two positionally disordered Bi{sup 3+} cations were observed in the marginal part of the slabs. The slabs are extending along b axis and are linked by inter-slab portion of the structure composed of VO{sub 4} tetrahedra and BiO{sub 6−x} coordination polyhedra, where x is a number of vacant oxygen sites. Raman spectra verified the coordination environment of vanadium atoms in the structure. - Graphical abstract: The [4{sup ¯}01] projection of two slabs and inter-slab part of the structure in one layer parallel to the (3{sup ¯}08)=(002{sup ¯}){sub F} plane (F in subscript indicate a fluorite type structure). The large green circles are Bi atoms. Small blue circles represent partly and fully occupied O sites, respectively. Pink (hatched black) are V1O{sub 4} and blue (hatched white) are V2O{sub 4} coordination tetrahedra. - Highlights: • Single crystals of Bi{sub 28}V{sub 8}O{sub 62} were grown using hydrothermal technique. • The crystal structure of Bi{sub 28}V{sub 8}O{sub 62} was solved using single-crystal XRD method. • Bi{sub 28}V{sub 8}O{sub 62} has an anion-deficient fluorite-related superstructure. • Raman spectrum confirmed the coordination environment of vanadium atoms. • Relation to the structurally related compound was discussed.

  6. Superstructure of NiAs

    Nozue, Tatsuhiro; Kobayashi, Hisao; Kamimura, Takashi; Yamaguchi, Yasuo

    2001-01-01

    The structural transition in NiAs was studied by neutron diffraction on the single crystalline sample. The crystal structure of NiAs has been reported to be bottom-centered orthorhombic with Cmc2 1 symmetry (niccolite-type). The measurement of temperature dependence of the powder X-ray diffraction revealed that NiAs undergoes a structural transition to the NiAs-type at T t =335 K. In present neutron diffraction experiment at room temperature, we observed the reflections indexed on the basis of the orthorhombic unit cell. The intensities of these reflections are qualitatively explained in terms of the niccolite-type structure with taking account of three domain structures, except for the weak reflections indexed as (001), (003) and (012). Then, the intensities of (001), (002) and (004) reflections were measured in temperature range of 20 to 420 K. The temperature dependences of (002) and (004) reflections qualitatively agree with those of the calculated intensities using the atomic positions of niccolite-type structure. However, the temperature dependence of (001) reflection shows the anomaly around T t , which suggests the symmetry of crystal structure of NiAs is not the Cmc2 1 symmetry. (author)

  7. Shear Bond Strength of Composite and Ceromer Superstructures to Direct Laser Sintered and Ni-Cr-Based Infrastructures Treated with KTP, Nd:YAG, and Er:YAG Lasers: An Experimental Study.

    Gorler, Oguzhan; Hubbezoglu, Ihsan; Ulgey, Melih; Zan, Recai; Guner, Kubra

    2018-04-01

    The aim of this study was to examine the shear bond strength (SBS) of ceromer and nanohybrid composite to direct laser sintered (DLS) Cr-Co and Ni-Cr-based metal infrastructures treated with erbium-doped yttrium aluminum garnet (Er:YAG), neodymium-doped yttrium aluminum garnet (Nd:YAG), and potassium titanyl phosphate (KTP) laser modalities in in vitro settings. Experimental specimens had four sets (n = 32) including two DLS infrastructures with ceromer and nanohybrid composite superstructures and two Ni-Cr-based infrastructures with ceromer and nanohybrid composite superstructures. Of each infrastructure set, the specimens randomized into four treatment modalities (n = 8): no treatment (controls) and Er:YAG, Nd:YAG, and KTP lasers. The infrastructures were prepared in the final dimensions of 7 × 3 mm. Ceromer and nanohybrid composite was applied to the infrastructures after their surface treatments according to randomization. The SBS of specimens was measured to test the efficacy of surface treatments. Representative scanning electron microscopy (SEM) images after laser treatments were obtained. Overall, in current experimental settings, Nd:YAG, KTP, and Er:YAG lasers, in order of efficacy, are effective to improve the bonding of ceromer and nanohybrid composite to the DLS and Ni-Cr-based infrastructures (p laser is more effective in the DLS/ceromer infrastructures (p laser, as second more effective preparation, is more effective in the DLS/ceromer infrastructures (p laser modalities, in order of success, Nd:YAG, KTP, and Er:YAG, are effective to increase bonding of these structures.

  8. Zr 2Ir 6B with an eightfold superstructure of the cubic perovskite-like boride ZrIr 3B 0.5: Synthesis, crystal structure and bonding analysis

    Hermus, Martin; Fokwa, Boniface P. T.

    2010-04-01

    Single phase powder samples and single crystals of Zr 2Ir 6B were successfully synthesized by arc-melting the elements in a water-cooled copper crucible under an argon atmosphere. Superstructure reflections were observed both on powder and on single crystal diffraction data, leading to an eightfold superstructure of ZrIr 3B x phase. The new phase, which has a metallic luster, crystallizes in space group Fm3¯m (no. 225) with the lattice parameters a=7.9903(4) Å, V=510.14(4) Å 3. Its crystal structure was refined on the basis of powder as well as single crystal data. The single crystal refinement converged to R1=0.0239 and w R2=0.0624 for all 88 unique reflections and 6 parameters. Zr 2Ir 6B is isotypic to Ti 2Rh 6B and its structure can be described as a defect double perovskite, A2BB' O6, where the A site is occupied by zirconium, the B site by boron, the O site by iridium but the B' site is vacant, leading to the formation of empty and boron-filled octahedral Ir 6 clusters. According to the result of tight-binding electronic structure calculations, Ir-B and Ir-Zr interactions are mainly responsible for the structural stability of the phase. According to COHP bonding analysis, the strongest bonding occurs for the Ir-B contacts, and the Ir-Ir bonding within the empty clusters is two times stronger than that in the BIr 6 octahedra.

  9. All-in-one bioprobe devised with hierarchical-ordered magnetic NiCo2O4 superstructure for ultrasensitive dual-readout immunosensor for logic diagnosis of tumor marker.

    Dai, Hong; Gong, Lingshan; Zhang, Shupei; Xu, Guifang; Li, Yilin; Hong, Zhensheng; Lin, Yanyu

    2016-03-15

    A new enzyme-free all-in-one bioprobe, consisted of hematin decorated magnetic NiCo2O4 superstructure (ATS-MNS-Hb), was designed for ultrasensitive photoelectrochemical and electrochemical dual-readout immunosensing of carcinoembryonic antigen (CEA) on carbon nanohorns (CNH) support. Herein, the MNS, possessed hierarchical-ordered structure, good porosity and magnetism, acted as nanocarrier to absorb abundant Hb molecular after functionalization, providing a convenient collection means by magnetic control as well as enhanced dual-readout sensing performances. CNH superstructures were employed as support to immobilize abounding captured antibodies, and then as-designed dual mode bioprobe, covalent binding with secondary antibody of CEA, was introduced for ultrasensitive detection of CEA by sandwich immunosensing. Photoelectrochemical response originated from plentiful hematin molecular, a excellent photosensitizer with good visible light harvesting efficiency, absorbed by functionalized porous MNS. The resultant concentration dependant linear calibration range was from 10 fg/mL to 1 ng/mL with ultralow detection limit of 10 fg/mL. For electrochemical process, catalase-like property of MNS was validated, moreover, MNS-Hb hybrid exhibited much higher mimic enzyme catalytic activity and evidently amplified electrocatalytic signal, performing a wide dynamic linear range from 1 ng/mL to 40 ng/mL with low detection limit of 1 ng/mL. Additionally, due to the improved accuracy of dual signals detection, the exact diagnoses of serum samples were gotten by operating resulting dual signals with AND logic system. This work demonstrated the promising application of MNS in developing ultrasensitive, cost-effective and environment friendly dual-readout immunosensor and accurate diagnoses strategy for tumor markers. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Implant-supported removable partial dentures in the mandible

    Louwerse, Charlotte

    2017-01-01

    Conventional removable partial dentures (RPD) in a free-ending situation in the lower jaw (i.e. only front teeth left) have a poor reputation. Several problems like discomfort and functional problems are frequently encountered, resulting in dissatisfied patients and desperate dentists. By supporting

  11. Implant-supported prostheses versus conventional permanent and removable dentures

    Koszuta Agnieszka

    2014-06-01

    Full Text Available Social, economic and technological progress results in an increasing range of treatment and rehabilitation methods for patients with partial or complete edentulism. The role of the dentist is to inform the patient about the full range of available missing teeth treatment options leading to complete rehabilitation of the masticatory organ in agreement with the patient’s aesthetic and functional expectations. The aim of the paper was to identify the type of prostheses used by patients before opting for implantsupported teeth replacements, according to the patients’ age, sex, marital status, place of residence and education. The study covered 464 patients, women and men, aged 20-74, treated with dental implants. The patients answered questions in an anonymous questionnaire. The influence of the prosthetic replacement type according to age and marital status was highly statistically significant, whereas it was statistically significant according to sex, place of residence and education. The female respondents who previously used tissue-borne complete or partial dentures opted for implant treatment more frequently. The respondents younger than 40 and between 40-60 years of age who did not previously used any prosthetic replacements opted for implant treatment more frequently. The respondents who did not use any prosthetic replacements decided to undergo implant treatment most frequently, regardless of their marital status, education and place of residence. The patients opted for implant treatment to improve their quality of life, despite the high cost of such therapy.

  12. Manufacturing implant supported auricular prostheses by rapid prototyping techniques.

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-08-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses.

  13. Manufacturing Implant Supported Auricular Prostheses by Rapid Prototyping Techniques

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-01-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadv...

  14. Management of aggressive periodontitis patient with implant supported prosthesis

    Garima Jain

    2015-01-01

    Full Text Available Aggressive periodontitis (AgP comprises a group of rare, often severe, rapidly progressive forms of periodontitis which is characterized by an early age of clinical manifestations. It usually affects people under 30 years of age, but patients may be older. Microbiota associated are Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis. The presence of highly pathogenic bacteria, severe periodontal bone destruction and the refractory nature of this disease tends to deter the clinician from placing implants in these patients. This case report demonstrates the placement of implants in a patient with AgP with successful 18 months follow-up.

  15. Implant support for removable partial overdentures: a case report.

    Halterman, S M; Rivers, J A; Keith, J D; Nelson, D R

    1999-01-01

    Functional stability and the preservation of remaining alveolar bone are primary, and often elusive, goals when restoring the partially edentulous arch. The incorporation of dental implants for the partial support of removable prostheses offers a practical adjunct in the fulfillment of these objectives. Planning for complex courses of treatment that include dental implants requires close coordination between the surgeon and the restorative dentist. Decisions that deal with type, location, size, number of implant fixtures, and design of the prosthesis are critical. All of these areas must be discussed and established as acceptable to the patient and each clinician before the initiation of treatment. In this report, we present a course of patient treatment in which a removable partial denture is supported by natural remaining teeth in conjunction with osseointegrated implants.

  16. Implant-supported Mandibular Overdentures in Very Old Adults

    Müller, F.; Duvernay, E.; Loup, A.; Vazquez, L.; Herrmann, F.R.; Schimmel, M.

    2013-01-01

    The purpose of this study was (1) to investigate denture satisfaction following the conversion of existing mandibular complete dentures to implant overdentures (IOD) in very old edentulous patients who depend on help for activities of daily living and (2) to evaluate secondary end points, such as functional, structural, nutritional, and patient-centered aspects. For this randomized clinical trial, 2 interforaminal short implants were placed in the intervention group (n = 16, 85.0 ± 6.19 yrs) to retain mandibular IODs; the control group (n = 18, 84.1 ± 5.55 yrs) received conventional relines. During the first year, no implant was lost; however, 2 patients died. IODs proved more stable, and participants in the intervention group demonstrated significantly higher denture satisfaction as well as an increased oral health–related quality of life compared to the control group. Maximum voluntary bite force improved significantly with IODs, yet the chewing efficiency was not different between groups. Masseter muscle thickness increased with IODs, mainly on the preferred chewing side. Body mass index decreased in both groups, but the decline tended to be smaller in the intervention group; blood markers and the Mini Nutritional Assessment did not confirm this tendency. These results indicate that edentulous patients who depend on help for activities of daily living may benefit from IODs even late in life (ClinicalTrial.gov NCT01928004). PMID:24158342

  17. Financial incentives: only one piece of the workplace wellness puzzle comment on "corporate wellness programs: implementation challenges in the modern american workplace".

    Busum, Kristin Van; Mattke, Soeren

    2013-11-01

    In this commentary, we argue that financial incentives are only one of many key components that employers should consider when designing and implementing a workplace wellness program. Strategies such as social encouragement and providing token rewards may also be effective in improving awareness and engagement. Should employers choose to utilize financial incentives, they should tailor them to the goals for the program as well as the targeted behaviors and health outcomes.

  18. Investigations related to a one-piece removal of the reactor block in the frame of the JRR-3 reconstruction program

    Onishi, N.; Kanenari, A.; Futamura, Y.; Sakurai, H.; Suzuki, S.; Nagase, T.; Iwatani, A.; Otsubo, F.

    1987-01-01

    In the Japan Atomic Energy Research Institute (JAERI), an outdated research reactor (Japan Research Reactor No.3; JRR-3) was removed to a storage facility between October 14th and November 7th, 1986. The removal of the 2250-ton reactor block (10 x 10 x 10 m) was performed as a part of a program to replace the JRR-3's core (10-MW thermal) with an upgraded research reactor core. The heavy water and fuel elements were taken out from the JRR-3 before removal work began. The reactor block was raised about 3.7 meters, using a 12-cubic meter steel frame and a center-hole jack system. The reactor block was then transported horizontally about 34 meters on steel rails, using four 100-ton jacks, to a storage facility. Finally, the reactor block was lowered 14 meters into the storage facility. After the reactor block was stored, a new 20-MW thermal, light-water moderated and cooled JRR-3 core will be built, with criticality targeted for 1989

  19. Evaluation of anterior segment changes using ultrasound biomicroscopy following phacoemulsification and implantation of one-piece and three-piece intraocular lenses in high myopia

    Reham Mohamed Samy

    2017-01-01

    The study of this correlation is to help in answering an important question − that is, does one diameter IOL fit all capsular bags? The statistical analyses in both groups point to a statistically significant correlation between the diameters of the capsular bags and the diameters of the implanted IOLs in both groups A and B, which demonstrates the absence of fitting of both sorts of IOLs in relation to the enlarged capsular bags of the highly myopic eyes − i.e. it focuses on the divergence between the size of the IOLs and that of the capsular bag.

  20. Financial Incentives: Only One Piece of the Workplace Wellness Puzzle; Comment on “Corporate Wellness Programs: Implementation Challenges in the Modern American Workplace”

    Kristin Van Busum

    2013-11-01

    Full Text Available In this commentary, we argue that financial incentives are only one of many key components that employers should consider when designing and implementing a workplace wellness program. Strategies such as social encouragement and providing token rewards may also be effective in improving awareness and engagement. Should employers choose to utilize financial incentives, they should tailor them to the goals for the program as well as the targeted behaviors and health outcomes.

  1. Participatory Research as One Piece of the Puzzle: A Systematic Review of Consumer Involvement in Design of Technology-Based Youth Mental Health and Well-Being Interventions

    Lawn, Sharon; Venning, Anthony; Winsall, Megan; Jones, Gabrielle M; Wyld, Kaisha; Damarell, Raechel A; Antezana, Gaston; Schrader, Geoffrey; Smith, David; Collin, Philippa; Bidargaddi, Niranjan

    2015-01-01

    Background Despite the potential of technology-based mental health interventions for young people, limited uptake and/or adherence is a significant challenge. It is thought that involving young people in the development and delivery of services designed for them leads to better engagement. Further research is required to understand the role of participatory approaches in design of technology-based mental health and well-being interventions for youth. Objective To investigate consumer involvement processes and associated outcomes from studies using participatory methods in development of technology-based mental health and well-being interventions for youth. Methods Fifteen electronic databases, using both resource-specific subject headings and text words, were searched describing 2 broad concepts-participatory research and mental health/illness. Grey literature was accessed via Google Advanced search, and relevant conference Web sites and reference lists were also searched. A first screening of titles/abstracts eliminated irrelevant citations and documents. The remaining citations were screened by a second reviewer. Full text articles were double screened. All projects employing participatory research processes in development and/or design of (ICT/digital) technology-based youth mental health and well-being interventions were included. No date restrictions were applied; English language only. Data on consumer involvement, research and design process, and outcomes were extracted via framework analysis. Results A total of 6210 studies were reviewed, 38 full articles retrieved, and 17 included in this study. It was found that consumer participation was predominantly consultative and consumerist in nature and involved design specification and intervention development, and usability/pilot testing. Sustainable participation was difficult to achieve. Projects reported clear dichotomies around designer/researcher and consumer assumptions of effective and acceptable interventions. It was not possible to determine the impact of participatory research on intervention effectiveness due to lack of outcome data. Planning for or having pre-existing implementation sites assisted implementation. The review also revealed a lack of theory-based design and process evaluation. Conclusions Consumer consultations helped shape intervention design. However, with little evidence of outcomes and a lack of implementation following piloting, the value of participatory research remains unclear. PMID:27025279

  2. Magnetosome chain superstructure in uncultured magnetotactic bacteria

    Abraçado, Leida G; Farina, Marcos; Abreu, Fernanda; Keim, Carolina N; Lins, Ulysses; Campos, Andrea P C

    2010-01-01

    Magnetotactic bacteria produce magnetosomes, which are magnetic particles enveloped by biological membranes, in a highly controlled mineralization process. Magnetosomes are used to navigate in magnetic fields by a phenomenon called magnetotaxis. Two levels of organization and control are recognized in magnetosomes. First, magnetotactic bacteria create a spatially distinct environment within vesicles defined by their membranes. In the vesicles, the bacteria control the size, composition and purity of the mineral content of the magnetic particles. Unique crystal morphologies are produced in magnetosomes as a consequence of this bacterial control. Second, magnetotactic bacteria organize the magnetosomes in chains within the cell body. It has been shown in a particular case that the chains are positioned within the cell body in specific locations defined by filamentous cytoskeleton elements. Here, we describe an additional level of organization of the magnetosome chains in uncultured magnetotactic cocci found in marine and freshwater sediments. Electron microscopy analysis of the magnetosome chains using a goniometer showed that the magnetic crystals in both types of bacteria are not oriented at random along the crystal chain. Instead, the magnetosomes have specific orientations relative to the other magnetosomes in the chain. Each crystal is rotated either 60°, 180° or 300° relative to their neighbors along the chain axis, causing the overlapping of the (1 1 1) and (1-bar 1-bar 1-bar) capping faces of neighboring crystals. We suggest that genetic determinants that are not present or active in bacteria with magnetosomes randomly rotated within a chain must be present in bacteria that organize magnetosomes so precisely. This particular organization may also be used as an indicative biosignature of magnetosomes in the study of magnetofossils in the cases where this symmetry is observed

  3. NANOMETER SUPERSTRUCTURE IN LIQUID ALKALI THALLIUM ALLOYS

    XU, R; VERKERK, P; HOWELLS, WS; DEWIJS, GA; VANDERHORST, F; VANDERLUGT, W

    1993-01-01

    Structure factors obtained from neutron diffraction measurements on liquid K-Tl and Cs-Tl alloys exhibit large prepeaks at approximately 0.77 angstrom-1 and 0.70 angstrom-1, respectively. It is concluded that the liquid contains large units of thallium atoms, possibly bearing some resemblance to

  4. Retention Strength of Conical Welding Caps for Fixed Implant-Supported Prostheses.

    Nardi, Diego; Degidi, Marco; Sighinolfi, Gianluca; Tebbel, Florian; Marchetti, Claudio

    This study evaluated the retention strength of welding caps for Ankylos standard abutments using a pull-out test. Each sample consisted of an implant abutment and its welding cap. The tests were performed with a Zwick Roell testing machine with a 1-kN load cell. The retention strength of the welding caps increased with higher abutment diameters and higher head heights and was comparable or superior to the values reported in the literature for the temporary cements used in implant dentistry. Welding caps provide a reliable connection between an abutment and a fixed prosthesis without the use of cement.

  5. Can hyaluronan injections augment deficient papillae at implant-supported crowns in the anterior maxilla?

    Bertl, Kristina; Gotfredsen, Klaus; Jensen, Simon S

    2017-01-01

    index score (MPIS), and standard clinical periodontal parameters. Pain level after injection was recorded on a visual analogue scale (VAS). The deficient area was evaluated on clinical photographs, and the esthetic appearance was recorded on a VAS. Differences in mucosal volume were assessed after 3...... groups; MPIS was 2 for all patients at all time points. Similarly, insignificant differences between groups or time points were observed for deficient area, gingival volume changes, bone level, and esthetic appearance. There were no differences in pain level between groups during injection...

  6. Replacement of missing tooth in esthetic zone with implant-supported fixed prosthesis

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available In the anterior region, the common reason for tooth loss is due to traumatic injury or congenital anomaly. Loss of a single tooth may cause functional and esthetic deficits to the patient. There are different treatment options available for replacing a missing incisor. Implant dentistry should be considered as first treatment alternative for replace a missing tooth. This case report presents the replacement of a missing maxillary left central incisor in a compromised site with dental implants along with bone graft followed by frenectomy to obtain a good clinical result and for better function and esthetics of the patient.

  7. [Influence of attachment type on stress distribution of implant-supported removable partial dentures].

    Yang, Xue; Rong, Qi-guo; Yang, Ya-dong

    2015-02-18

    To compare influences of different retention attachments on stress among supporting structures. By 3-dimensional laser scanner and reverse engineering computer aided design (CAD) software, a basic partially edentulous digital model with mandibular premolar and molar missing was established. Implant attachment and removable partial dentures (RPD) were added into the basic model to build three kinds of models: RPD only, RPD + implant + Locator attachment, and RPD + implant + Magfit attachment. Vertical and inclined loads were put on artificial teeth unilaterally. By means of 3-dimensional finite element analysis, the stress distribution and displacement of the main supportive structures were compared. A complete 3-dimensional finite element model was established, which contained tooth structure, and periodontal structures. The displacement of the denture was smaller in Locator (9.38 μm vertically, 45.48 μm obliquely) and Magfit models (9.54 μm vertically, 39.45 μm obliquely) compared with non-implant RPD model (95.27 μm vertically, 155.70 μm obliquely). Compared with the two different attachments, cortical bone stress value was higher in Locator model (Locator model 10.850 MPa vertically, 43.760 MPa obliquely; Magfit model 7.100 MPa vertically, 19.260 MPa obliquely).The stress value of abutment periodontal ligamentin Magfit model (0.420 MPa vertically) was lower than that in Locator model (0.520 MPa vertically). The existence of implant could reduce maximum von Mises value of each supportive structure when Kennedy I partially edentulous mandible was restored. Comparing the structure of Magfit and Locator attachment, the contact of Magfit attachment was rigid, while Locator was resilient. Locator attachment could improve stability of the denture dramatically. Locator had stronger effect on defending horizontal movement of the denture.

  8. Perioprosthetic and Implant-Supported Rehabilitation of Complex Cases: Clinical Management and Timing Strategy.

    Landi, Luca; Piccinelli, Stefano; Raia, Roberto; Marinotti, Fabio; Manicone, Paolo Francesco

    2016-01-01

    Treatment of complex perioprosthetic cases is one of the clinical challenges of everyday practice. Only a complete and thorough diagnostic setup may allow the clinician to formulate a realistic prognosis to select the abutments to support prosthetic rehabilitation. Clinical, radiographic, or laboratory parameters used separately are useless to correctly assign a reliable prognosis to single teeth except in the case of a clearly hopeless tooth. Therefore, it is crucial to gather the greatest quantity of data to determine the role that every single element can play in the prosthetic rehabilitation of the case. The following report deals with the management of a multidisciplinary periodontally compromised case in which a treatment strategy and chronology were designed to reach clinical predictability while reducing the duration of the therapy.

  9. Perioprosthetic and Implant-Supported Rehabilitation of Complex Cases: Clinical Management and Timing Strategy

    Luca Landi

    2016-01-01

    Full Text Available Treatment of complex perioprosthetic cases is one of the clinical challenges of everyday practice. Only a complete and thorough diagnostic setup may allow the clinician to formulate a realistic prognosis to select the abutments to support prosthetic rehabilitation. Clinical, radiographic, or laboratory parameters used separately are useless to correctly assign a reliable prognosis to single teeth except in the case of a clearly hopeless tooth. Therefore, it is crucial to gather the greatest quantity of data to determine the role that every single element can play in the prosthetic rehabilitation of the case. The following report deals with the management of a multidisciplinary periodontally compromised case in which a treatment strategy and chronology were designed to reach clinical predictability while reducing the duration of the therapy.

  10. REHABILITATION OF COMPLETELY EDENTULOUS MANDIBULAR ARCH USING IMPLANT SUPPORTED FIXED PROSTHESIS - A CASE REPORT.

    Kiran Kaushik; Pankaj Dhawan; Pankaj Madhukar; Piyush Tandan; Prateek Agarwal.

    2018-01-01

    Teeth are important structures in the oral cavity with many associated functions. Loss of teeth may be inevitable due to several reasons. Replacement of teeth should be done to restore the functions like mastication, phonetics, and esthetics. Modern dentistry aims to return patients to normal oral health and function in a predictable fashion. Satisfying a completely edentulous patient is always considered as a difficult task. Various treatment options for completely edentulous patients are av...

  11. Mini implant supported molar tubes: A novel method for attaching the molar tubes

    Nitin V Muralidhar

    2017-01-01

    Full Text Available Banding or bonding procedures have been the only means of attaching molar tubes onto the permanent molar teeth till date in the field of orthodontics. This clinical innovation aims to include the use of mini implant for the purpose of attaching the molar tubes thereby eliminating the iatrogenic effects of banding and bonding of the teeth.

  12. The Amount of Wear in Attachment of Implant-Supported Overdentures in Mandible

    Fariborz Vafaee

    2016-10-01

    Full Text Available Background and objectives: One of the simplest and cheapest attachments for overdentures, is the ball-type attachment, however, keeping it during the first year of prosthesis delivery and after that is one of the main concerns of dentists. The present study aimed to assess the wear of matrix in overdentures attachment supported by one, two and three implants in the mandible. Materials and methods: Thirty edentulous patients were randomly divided into three groups: the first group received a single implant in the midline of the lower mandible, the second group two implants in areas B and D, and the third group three implants in areas B, C, and D. The attachment used in patients’ prosthetic with single and two implants was O-ball/ring attachment and for patients with three implants, the treatment plan was ball bar-supported attachments. After placing the new matrix implant for each patient and obtaining their consent, the matrix wear was measured with CMM (Coordinate Measuring Machine device. To compare matrix wear after six months and one year, measurements were repeated. Data analysis, using ANOVA and multiple comparisons was down by Tukey Test. variance with repeated measures and Tukey test were used to compare the groups two-by-two. P.value less than 0.05 was set statistical significant. SPSS 16 software was used for data analysis. Results: The data obtained from the CMM device showed that the lowest mean matrix wear in the maximum single implant and maximum mean were in group two. Conclusion: Both time and the number of implants had a significant effect on the wear of the O-ring.

  13. Implant-supported rehabilitation after treatment of atrophic mandibular fractures: report of two cases.

    Oliveira, Leandro Benetti de; Gabrielli, Marisa Aparecida Cabrini; Gabrielli, Mario Francisco Real; Pereira-Filho, Valfrido Antonio Pereira

    2015-12-01

    The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (fractures. Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.

  14. Masticatory function and patient satisfaction with implant-supported mandibular overdentures: a prospective 5-year study

    Bakke, Merete; Holm, Betty; Gotfredsen, Klaus

    2002-01-01

    participated. They were in good health but had retention problems with their mandibular dentures. First, all patients received new dentures. After 3 months, two Astra Tech implants were placed in the anterior part of the mandible, and 6 months later the abutments were connected. Patient assessment...

  15. Fracture mode during cyclic loading of implant-supported single-tooth restorations

    Hosseini, Mandana; Kleven, Erik; Gotfredsen, Klaus

    2012-01-01

    restorations of zirconia abutment-retained crowns with zirconia copings veneered with glass-ceramics (n=8) and feldspathic ceramics (n=8). The control group was composed of 16 metal ceramic restorations of titanium abutment-retained crowns with gold alloy copings veneered with glass (n=8) and feldspathic...... ceramics (n=8). The palatal surfaces of the crowns were exposed to cyclic loading of 800 N with a frequency of 2 Hz, which continued to 4.2 million cycles or until fracture of the copings, abutments, or implants. The number of cycles and the fracture modes were recorded. The fracture modes were analyzed...

  16. Marginal tissue response adjacent to Astra Dental Implants supporting overdentures in the mandible

    Gotfredsen, K; Holm, B; Sewerin, I

    1993-01-01

    and by a bar attachment in 9 patients. Periodontal registrations were recorded 0 months, 6 months, 12 months and 24 months after the overdentures were inserted. One of the 40 fixtures was lost at the stage of abutment connection. No fixtures were lost during the 2- to 4-year observation period and no fixtures...

  17. Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

    Farzin, Mitra; Torabi, Kianoosh; Ahangari, Ahmad Hasan; Derafshi, Reza

    2014-01-01

    Objective: Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. Materials and Method: Two prefabricated abutments were attached to their corresponding analogs and embedded in an acrylic resin block. The first abutment (control group) was left intact without any modifications. The screw access channel for the first abutment was completely filled with composite resin. In the second abutment, (test group) the axial wall was partially removed to form an abutment with 3 walls. Wax models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The prepared copings were cemented on the abutments by Temp Bond luting agent under standardized conditions (n=20). The assemblies were stored in 100% humidity for one day at 37°C prior to testing. The cast crown was removed from the abutment using an Instron machine, and the peak removal force was recorded. Coping/abutment specimens were cleaned after testing, and the testing procedure was repeated for Dycal luting agent (n=20). Data were analyzed with two- way ANOVA (α=0.05). Results: There was no significant difference in the mean transformed retention (Ln-R) between intact abutments (4.90±0.37) and the abutments with 3 walls (4.83±0.25) using Dycal luting agent. However, in TempBond group, the mean transformed retention (Ln-R) was significantly lower in the intact abutment (3.9±0.23) compared to the abutment with 3 walls (4.13±0.33, P=0.027). Conclusion: The retention of cement-retained implant restoration can be improved by the type of temporary cement used. The retention of cast crowns cemented to implant abutments with TempBond is influenced by the wall removal. PMID:25628660

  18. A comparative evaluation of implant supported zirconia framework gap of two CAD/CAM systems

    Narges Ameri

    2016-11-01

    computer-aided manufacturing (CAM systems (AmannGirrbach and Zirkonzahn. Materials and Methods: The master model of 3-unit FDP was made of two implant abutments (AmannGirrbach and Zirkonzahn from canine to second premolar. Twelve frameworks were manufactured using each fabricating system from semi-sintered zirconia blanks, which had to be sintered for final density after milling. After manufacturing, the absolute marginal discrepancy in each abutment were determined by means of Video Measurement System (VMS. The data were analyzed, using independent and paired t test (P=0.05. Results: For the premolar abutment, the absolute marginal discrepancy of frameworks fabricated by AmannGirrbach system was significantly greater than those of the other system (P=0.005. There was no significant difference between the marginal discrepancy of canine and premolar abutments (P>0.05. Conclusion: Within the limitations of this study, it could be concluded that the marginal fit of zirconia FDPs was significantly dependent on the CAD/CAM system used, but the abutment size was not an effective factor.

  19. Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

    Farzin, Mitra; Torabi, Kianoosh; Ahangari, Ahmad Hasan; Derafshi, Reza

    2014-01-01

    Objective: Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. Materials and Method: Two prefabricated abutments were attached to their corresponding analogs and embedded in an ac...

  20. Effect of abutment modification and cement type on retention of cement-retained implant supported crowns.

    Mitra Farzin

    2014-06-01

    Full Text Available Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations.Two prefabricated abutments were attached to their corresponding analogs and embedded in an acrylic resin block. The first abutment (control group was left intact without any modifications. The screw access channel for the first abutment was completely filled with composite resin. In the second abutment, (test group the axial wall was partially removed to form an abutment with 3 walls. Wax models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The prepared copings were cemented on the abutments by Temp Bond luting agent under standardized conditions (n=20. The assemblies were stored in 100% humidity for one day at 37°C prior to testing. The cast crown was removed from the abutment using an Instron machine, and the peak removal force was recorded. Coping/abutment specimens were cleaned after testing, and the testing procedure was repeated for Dycal luting agent (n=20. Data were analyzed with two- way ANOVA (α=0.05.There was no significant difference in the mean transformed retention (Ln-R between intact abutments (4.90±0.37 and the abutments with 3 walls (4.83±0.25 using Dycal luting agent. However, in TempBond group, the mean transformed retention (Ln-R was significantly lower in the intact abutment (3.9±0.23 compared to the abutment with 3 walls (4.13±0.33, P=0.027.The retention of cement-retained implant restoration can be improved by the type of temporary cement used. The retention of cast crowns cemented to implant abutments with TempBond is influenced by the wall removal.

  1. Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests

    Mariane Miyashiro

    2011-06-01

    Full Text Available OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5. RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20 for PU-1, 347.90 MPa (SD=109.54 for PU-2 and 304.64 MPa (SD=25.48 for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.

  2. Crown color match of implant-supported zirconia and Porcelain-Fused-to-Metal restorations:

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2014-01-01

    ShadeTM, Micro Dental) in CIEL¿a¿b¿ coordinates. Subjective crown color match scores were evaluated. Independent sample t test of SPSS17.0 was used to compare the difference between zirconia restoration and PFM restoration. Spearman correlation was used to analyze the relationship between the spectrophotometric...

  3. Comparative evaluation of the oral tactile function by means of teeth or implant-supported prostheses.

    Jacobs, R; van Steenberghe, D

    1991-01-01

    To clarify more of the tactile function of oral implants, both an interocclusal thickness detection and discrimination task were carried out in 4 different test conditions on 37 patients: t (tooth)/t, i (implant)/t, i/i and d (denture)/o (overdenture supported by implants). For the interocclusal detection of steel foils, the 50% detection threshold level (RL) in the 4 conditions was 20, 48, 64 and 108 microns, respectively, which indicates significant differences. The ability to discriminate interdental thickness differences was tested with a 0.2 and 1.0 mm standard. It was evaluated as the 75% discrimination level (DL). In the 0.2 mm discrimination task, corresponding DL-values for the t/t, i/t, i/i and d/o condition were 25, 55, 66 and 134 microns, whereas the 1.0 mm standard gave values of 193, 293, 336 and 348 microns, respectively. All results differed significantly from each other (p less than 0.05) except for the i/i-d/o comparison of the 1.0 mm discrimination task where the difference was negligible. The present findings indicate that the tactile sensibility of implants is reduced with regard to natural teeth. Remaining receptors of the peri-implant tissues might play a compensatory role in the decreased exteroceptive function.

  4. Survival of various implant-supported prosthesis designs following 36 months of clinical function.

    Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S

    2000-12-01

    The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

  5. Retention Strength after Compressive Cyclic Loading of Five Luting Agents Used in Implant-Supported Prostheses

    Angel Alvarez-Arenal

    2016-01-01

    Full Text Available The purpose of this study was to evaluate and compare the retention strength of five cement types commonly used in implant-retained fixed partial dentures, before and after compressive cyclic loading. In five solid abutments screwed to 5 implant analogs, 50 metal Cr-Ni alloy copings were cemented with five luting agents: resin-modified glass ionomer (RmGI, resin composite (RC, glass ionomer (GI, resin urethane-based (RUB, and compomer cement (CC. Two tensile tests were conducted with a universal testing machine, one after the first luting of the copings and the other after 100,000 cycles of 100 N loading at 0.72 Hz. The one way ANOVA test was applied for the statistical analysis using the post hoc Tukey test when required. Before and after applying the compressive load, RmGI and RC cement types showed the greatest retention strength. After compressive loading, RUB cement showed the highest percentage loss of retention (64.45%. GI cement recorded the lowest retention strength (50.35 N and the resin composite cement recorded the highest (352.02 N. The type of cement influences the retention loss. The clinician should give preference to lower retention strength cement (RUB, CC, and GI if he envisages any complications and a high retention strength one (RmGI, RC for a specific clinical situation.

  6. A finite element study on stress distribution of two different attachment designs under implant supported overdenture

    Mohamed I. El-Anwar

    2015-10-01

    Conclusions: Locator and ball and socket attachments induce equivalent stresses on bone surrounding implants. Locator attachment performance was superior to that of the ball and socket attachment in the implants, nylon caps, and overdenture. Locator attachments are highly recommended and can increase the interval between successive maintenance sessions.

  7. Comparison of patient's satisfaction with implant-supported mandibular overdentures and complete dentures

    Yu-Hwa Pan

    2014-06-01

    Full Text Available Background: The purpose of this study was to compare patients' subjective experiences with respect to long-term satisfaction with mandibular implant-retained overdentures versus conventional complete dentures. Methods: Among 85 completely edentulous patients, 60 were treated with four one-stage titanium implants and overdentures retained by a cast bar with extracoronal attachments. These patients constituted the experimental group, and were subsequently evaluated clinically over a period of up to 6 years. The other 25 patients constituted the control group and were treated with conventional complete dentures without implant retained. All the patients (n = 60 in the experimental group responded to questions on their experiences before and after treatment with the implant-retained overdentures. Sixty percent (n = 15 of the 25 patients in the control group responded to the questionnaire. Results: No implants or restorations failed during the observation period. The experimental group, however, showed significant differences with the control group in terms of their responses to the questionnaire. Conclusion: The use of implants to retain and support the overdenture improved comfort and gave the experimental patients greater self-confidence in social interactions, in addition to more effective oral rehabilitation. The results demonstrate that the effects of rehabilitation of the mandibular arch with an implant-retained overdenture are predictable.

  8. Photoelastic Stress Analysis Surrounding Implant-Supported Prosthesis and Alveolar Ridge on Mandibular Overdentures

    Dorival Pedroso da Silva

    2010-01-01

    Full Text Available The purpose of this research was to evaluate the maximum stress around osseointegrated implants and alveolar ridge, in a mandible with left partial resection through a photoelastic mandibular model. The first group consisted of two implants: traditional model (T, implants placed in the position of both canines; fulcrum model (F, implants placed in the position of left canine CL and right lateral incisor LiR. Both models linked through a bar and clips. The second group was consisted of three implants, with implants placed in the position of both canines (CR and CL and the right lateral incisor (LiR, which composed four groups: (1 model with 3 “O” rings, (2 model 2 ERAs, bar with clips, (3 model 2 ERAs bar without clips; (4 model “O” ring bar and ERA. An axial and an oblique load of 6.8 kgf was applied on a overdenture at the 1st Pm, 2nd Pm, and 1st M. Results showed that the area around the left canine (CL was practically free of stress; the left lateral incisor (LiL developed only small tensions, and low stress in all the other cases; the right canine tooth suffered the largest concentrations of stress, mainly with the ERA retention mechanism.

  9. Improving the fit of implant prosthetics: an in vitro study.

    Yannikakis, Stavros; Prombonas, Anthony

    2013-01-01

    Accurate and passive fit between a prosthesis and its supporting implants has been considered a prerequisite for successful long-term osseointegration. The objective of this in vitro study was to evaluate the strain development during tightening of a five-unit screw-retained superstructure constructed using five different methods. Five-unit screw-retained fixed partial prostheses (n = 25) were fabricated on three implants embedded in an epoxy resin block using five different methods: (1) cobalt-chromium (Co-Cr), plastic cylinders, one-piece cast; (2) Co-Cr, plastic cylinders, framework sectioned, preceramic laser-welding soldering; (3) gold-platinum (Au-Pt), gold cylinders, one-piece cast; (4) Au-Pt, gold cylinders, framework sectioned, preceramic laser-welding soldering; (5) Co-Cr, one-piece cast, and cementation to "passive abutments" (Southern Implants) after final finishing and polishing. Strain gauges (SG) were attached to the fixed partial prosthesis (FPP) and to the resin block to measure the stress created during screw tightening. The combination of Co-Cr alloy and plastic cylinders in a one-piece cast showed such an inadequate fit among the fabricated methods that this group was excluded from the remainder of the experiment. Specimens of Au-Pt cast on gold cylinders in one piece showed higher strain development than the other groups used in this study, with strains ranging from 223.1 to 2,198.1 Μm/m. Sectioning and soldering significantly improved the overall fit. FPPs of Co-Cr in a one-piece cast cemented to "passive abutments" produced the best level of fit, with the least strain development in the prosthesis and the resin block (59 to 204.6 Μm/m). Absolute fit of superstructures on implants is not possible using conventional laboratory procedures. Cementing FPPs onto prefabricated cylinders directly onto the implants significantly reduces strain development compared to the other fabrication methods.

  10. Synthesis of biorefinery networks using a superstructure optimization based approach

    Bertran, Maria-Ona; Anaya-Reza, Omar; Lopez-Arenas, Maria Teresa

    Petroleum is currently the primary raw material for the production of fuels and chemicals. Consequently, our society is highly dependent on fossil non-renewable resources. However, renewable raw materials are recently receiving increasing interest for the production of chemicals and fuels, so a n...... of the proposed approach is shown through a practical case study for the production of valuable products (i.e. lysine and lactic acid) from sugarcane molasses; these alternatives are considered with respect to availability and demands in Mexico [4]....

  11. Exploring the morphological and electronic properties of silicene superstructures

    Grazianetti, Carlo; Chiappe, Daniele; Cinquanta, Eugenio; Tallarida, Grazia; Fanciulli, Marco; Molle, Alessandro

    2014-01-01

    Silicene, the Si counterpart of graphene, grows on Ag(111) forming domains. Investigation, by means of scanning tunneling microscopy, of morphological properties is carried out by considering post-deposition process. Particular attention is here addressed to the post-deposition annealing temperature, which plays an important role in determining the resulting morphology. On the other hand, electronic properties are probed by scanning tunneling spectroscopy and a position-dependent local density of states results, which can be understood in terms of symmetry breaking in the honeycomb lattice.

  12. Superstructure-based optimization tool for plant design and retrofitting

    Bozkurt, Hande; Gernaey, Krist V.; Sin, Gürkan

    2017-01-01

    Many wastewater treatment processes and technologies have been developed since the beginning of the20th century to meet increasingly stringent performance demands. Still the wastewater industry has beenfacing many new challenges such as increasing energy costs, presence of trace organics which has...

  13. Ways of ensuring the standard of bridge superstructures.

    M.G. Malgin; V.I. Kiryan

    2011-01-01

    The structural features of welded railway bridges of the last century were considered. The basic causes of appearance of fatigue cracks in welded joints of railway bridges were assessed. Structural and technological ways of provision of the design life of operated and new-built welded railway bridges are discussed.

  14. Ways of ensuring the standard of bridge superstructures.

    M.G. Malgin

    2011-12-01

    Full Text Available The structural features of welded railway bridges of the last century were considered. The basic causes of appearance of fatigue cracks in welded joints of railway bridges were assessed. Structural and technological ways of provision of the design life of operated and new-built welded railway bridges are discussed.

  15. Superstructured transition metial complexex -- A basis for functioning molecules

    Busch, D.H.

    1993-01-01

    This paper looks at the area of coordination chemistry as it relates to the problem of binding metal ions into complexes. This field has evolved greatly over the years, and at present there is much interest in developing molecular species which will bind with metal ions to remove them from various process steams for different reasons. The binding needs to be strong enough to hold the ions, but also not so strong as to override the process objectives. The author discusses how the host chemical environment, and the effect of the bound ion are taken into account in the design of new complexing agents

  16. Exploring the morphological and electronic properties of silicene superstructures

    Grazianetti, Carlo, E-mail: carlo.grazianetti@mdm.imm.cnr.it [Laboratorio MDM, IMM-CNR, via C. Olivetti 2, I-20864 Agrate Brianza, MB (Italy); Dipartimento di Scienza dei Materiali, Università degli Studi di Milano Bicocca, via R. Cozzi 53, I-20126 Milano, MI (Italy); Chiappe, Daniele; Cinquanta, Eugenio; Tallarida, Grazia [Laboratorio MDM, IMM-CNR, via C. Olivetti 2, I-20864 Agrate Brianza, MB (Italy); Fanciulli, Marco [Laboratorio MDM, IMM-CNR, via C. Olivetti 2, I-20864 Agrate Brianza, MB (Italy); Dipartimento di Scienza dei Materiali, Università degli Studi di Milano Bicocca, via R. Cozzi 53, I-20126 Milano, MI (Italy); Molle, Alessandro, E-mail: alessandro.molle@mdm.imm.cnr.it [Laboratorio MDM, IMM-CNR, via C. Olivetti 2, I-20864 Agrate Brianza, MB (Italy)

    2014-02-01

    Silicene, the Si counterpart of graphene, grows on Ag(111) forming domains. Investigation, by means of scanning tunneling microscopy, of morphological properties is carried out by considering post-deposition process. Particular attention is here addressed to the post-deposition annealing temperature, which plays an important role in determining the resulting morphology. On the other hand, electronic properties are probed by scanning tunneling spectroscopy and a position-dependent local density of states results, which can be understood in terms of symmetry breaking in the honeycomb lattice.

  17. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    Minatel, Lurian [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Verri, Fellippo Ramos [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); Kudo, Guilherme Abu Halawa [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); and others

    2017-02-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  18. Loading Variables on Implant-Supported Distal-Extension Removable Partial Dentures: An In Vitro Pilot Study.

    Hirata, Kiyotaka; Takahashi, Toshihito; Tomita, Akiko; Gonda, Tomoya; Maeda, Yoshinobu

    2016-01-01

    The aim of this study was to investigate strain on implants used for adjunctive support of distal extension removable partial dentures. An implant with strain gauges was used for testing purposes in two positions, parallel and inclined. Three loading scenarios--loading apparatus (LA), artificial teeth via cotton roll (CR), and artificial teeth (UT)--were studied and strains compared via the Kruskal-Wallis test (P=.05). Strain under CR was significantly larger than UT in parallel (P<.05). However, the opposite was observed in inclined. Strain in parallel was smallest for UT, whereas in inclined it was largest for CR.

  19. A 1-year randomised controlled trial comparing zirconia versus metal-ceramic implant supported single-tooth restorations

    Hosseini, Mandana; Worsaae, Nils; Schiødt, Morten

    2011-01-01

    , by blinded assessors. RESULTS: One-year after loading, no patient dropped out and no implant failed, though one MC restoration had to be remade. The marginal bone loss was not significantly different between AC and MC restorations (AC: mean 0.08 mm, SD 0.25; MC: mean 0.10 mm, SD 0.17). Seven out of 10...

  20. Fracture analysis of CAD-CAM high-density polymers used for interim implant-supported fixed, cantilevered prostheses.

    Yilmaz, Burak; Alp, Gülce; Seidt, Jeremy; Johnston, William M; Vitter, Roger; McGlumphy, Edwin A

    2018-01-06

    The load-to-fracture performance of computer-assisted design and computer-assisted manufacturing (CAD-CAM) high-density polymer (HDP) materials in cantilevers is unknown. The purposes of this in vitro study were to evaluate the load-to-fracture performance of CAD-CAM-fabricated HDPs and to compare that with performance of autopolymerized and injection-molded acrylic resins. Specimens from 8 different brands of CAD-CAM HDPs, including Brylic Solid (BS); Brylic Gradient (BG); AnaxCAD Temp EZ (AE); AnaxCAD Temp Plus (AP); Zirkonzahn Temp Basic (Z); GDS Tempo-CAD (GD); Polident (Po); Merz M-PM-Disc (MAT); an autopolymerized acrylic resin, Imident (Conv) and an injection-molded acrylic resin, SR-IvoBase High Impact (Inj) were evaluated for load-to-fracture analysis (n=5). CAD-CAM specimens were milled from poly(methyl methacrylate) (PMMA) blocks measuring 7 mm in buccolingual width, 8 mm in occlusocervical thickness, and 30 mm in length. A wax pattern was prepared in the same dimensions used for CAD-CAM specimens, flasked, and boiled out. Autopolymerizing acrylic resin was packed and polymerized in a pressure container for 30 minutes. An identical wax pattern was flasked and boiled out, and premeasured capsules were injected (SR-IvoBase) and polymerized under hydraulic pressure for 35 minutes for the injection-molded PMMA. Specimens were thermocycled 5000 times (5°C to 55°C) and fixed to a universal testing machine to receive static loads on the 10-mm cantilever, vertically at a 1 mm/min crosshead speed until fracture occurred. Maximum load-to-fracture values were recorded. ANOVA was used to analyze the maximum force values. Significant differences among materials were analyzed by using the Ryan-Einot-Gabriel-Welsch multiple range test (α=.05). Statistically significant differences were found among load-to-fracture values of different HDPs (PCAD-CAM polymer. GD and Po CAD-CAM materials had the highest load-to-fracture values. AE, AP, Z, MAT, and BS CAD-CAM polymers and injection-molded acrylic resin had similar load-to-fracture values, which were higher than those of BG and autopolymerized acrylic resin. Autopolymerized acrylic resin load-to-fracture value was similar to that of BG CAD-CAM polymer, which is colored in a gradient pattern. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns

    Lohbauer, Ulrich; Belli, Renan; Cune, Marco S; Schepke, Ulf

    2017-01-01

    Today, a substantial part of the dental crown production uses computer-aided design and computer-aided manufacturing (CAD/CAM) technology. A recent step in restorative dentistry is the replacement of natural tooth structure with pre-polymerized and machined resin-based methacrylic polymers.

  2. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    Minatel, Lurian; Verri, Fellippo Ramos; Kudo, Guilherme Abu Halawa; Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo

    2017-01-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  3. Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis.

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Bonfante, Estevam Augusto; Santiago Júnior, Joel Ferreira; Pellizzer, Eduardo Piza

    2018-03-01

    The systematic review and meta-analysis aimed to answer the PICO question: "Do patients that received external connection implants show similar marginal bone loss, implant survival and complication rates as internal connection implants?". Meta-analyses of marginal bone loss, survival rates of implants and complications rates were performed for the included studies. Study eligibility criteria included (1) randomized controlled trials (RCTs) and/or prospective, (2) studies with at least 10 patients, (3) direct comparison between connection types and (4) publications in English language. The Cochrane risk of bias tool was used to assess the quality and risk of bias in RCTs, while Newcastle-Ottawa scale was used for non-RCTs. A comprehensive search strategy was designed to identify published studies on PubMed/MEDLINE, Scopus, and The Cochrane Library databases up to October 2017. The search identified 661 references. Eleven studies (seven RCTs and four prospective studies) were included, with a total of 530 patients (mean age, 53.93 years), who had received a total of 1089 implants (461 external-connection and 628 internal-connection implants). The internal-connection implants exhibited lower marginal bone loss than external-connection implants (PInternal connections had lower marginal bone loss when compared to external connections. However, the implant-abutment connection had no influence on the implant's survival and complication rates. Based on the GRADE approach the evidence was classified as very low to moderate due to the study design, inconsistency, and publication bias. Thus, future research is highly encouraged. Internal connection implants should be preferred over external connection implants, especially when different risk factors that may contribute to increased marginal bone loss are present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Comparative three-dimensional finite element analysis of implant-supported fixed complete arch mandibular prostheses in two materials

    João Paulo Mendes Tribst

    2017-01-01

    Conclusions: The stress generated in all constituents of the system was not significantly influenced by the framework's material. This allows suggesting that in cases without components, the use of a framework in zirconia has biomechanical behavior similar to that of a Ti bar.

  5. Oral rehabilitation with an implant-supported mesostructure on a microvascularized mandibular graft: A 12-year follow-up study

    José Manuel Mendes

    2017-06-01

    Full Text Available Due to the increased survival of the population, treatment of oral cavity tumour patients is increasingly common. In this context, oral rehabilitation construction methods have been developed to contribute to improving the patient's quality of life. Developments in the areas of oral implantology and rehabilitation, along with microvascularized grafts, have increased the possibility of rehabilitating patients undergoing hemimandibulectomy with more effective and lasting treatment. This article aims to demonstrate an aesthetic and functional oral rehabilitation method, both in terms of the oral cavity and the lower face, in a young patient submitted to a left lateral hemimandibulectomy, using a mesostructure fixed onto implants.

  6. Functional aspects of treatment with implant-supported single crowns: a quality control study in subjects with tooth agenesis

    Goshima, Kenichi; Lexner, Michala O; Thomsen, Carsten Eckhart

    2010-01-01

    -Related Quality of Life (OHRQoL) in subjects with tooth agenesis. MATERIAL AND METHODS: In nine females and nine males (32 + or - 10 years) with agenesis treated with one to four ISSC (68% in the premolar region), the treatment effect and masticatory function were assessed. The evaluation was performed first...... after implant placement shortly before crown cementation, and again 1 month after cementation. It consisted of questionnaires [including Oral Health Impact Profile (OHIP-49)] and functional examination with plastic strips, the Dental Prescale Film and the Occluzer system, Xylitol color-changeable gum...... with ISSCs in subjects with tooth agenesis significantly increased masticatory function subjectively and clinically as well as OHRQoL. However, as the functional parameters before replacement of the teeth corresponded to values in subjects with complete dentitions, the functional importance of the increase...

  7. Influence of different catilever extensions and glass or polyamaramid reinforcement fibers on fracture strength of implant-supported temporary

    Paola Colán Guzmán

    2008-04-01

    Full Text Available In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid, considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment, while the distal portion (cantilever had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group or acrylic resin reinforced by glass (Fibrante, Angelus or polyaramide (Kevlar 49, Du Pont fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05 only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.

  8. Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns.

    Delben, Juliana Aparecida; Barão, Valentim Adelino Ricardo; Dos Santos, Paulo Henrique; Assunção, Wirley Gonçalves

    2014-02-01

    The effect of veneering materials on screw joint stability remains inconclusive. Thus, this study evaluated the preload maintenance of abutment screws of single crowns fabricated with different abutments and veneering materials. Sixty crowns were divided into five groups (n = 12): UCLA abutment in gold alloy with ceramic (group GC) and resin (group GR) veneering, UCLA abutment in titanium with ceramic (group TiC) and resin (group TiR) veneering, and zirconia abutment with ceramic veneering (group ZiC). Abutment screws made of gold were used with a 35 Ncm insertion torque. Detorque measurements were obtained initially and after mechanical cycling. Data were analyzed by ANOVA and Fisher's exact test at a significance level of 5%. For the initial detorque means (in Ncm), group TiC (21.4 ± 1.78) exhibited statistically lower torque maintenance than groups GC (23.9 ± 0.91), GR (24.1 ± 1.34), and TiR (23.2 ± 1.33) (p abutment type and veneering material. More irregular surfaces in the hexagon area of the castable abutments were observed. The superiority of any veneering material concerning preload maintenance was not established. © 2013 by the American College of Prosthodontists.

  9. A mandibular implant-supported fixed complete dental prosthesis in a patient with Sjogren syndrome: case report.

    Spinato, Sergio; Soardi, Carlo Maria; Zane, Anna Maria

    2010-06-01

    The article describes the treatment and 1 year follow-up of a patient with Sjogren syndrome, treated with 6 intraforaminal mandibular implants with delayed loading and an implant-retained fixed prosthesis. The maxillary arch has been treated with a complete denture. This made an enormous difference in comfort and function for the patient. Radiographic check-ups did not reveal any peri-implant bone loss after 1 year of loading.

  10. Attachment-retained gingival prosthesis for implant-supported fixed dental prosthesis in the maxilla: a clinical report.

    Aparecida de Mattias Sartori, Ivete; Uhlendorf, Yuri; Padovan, Luiz Eduardo Marques; Junior, Paulo Domingos Ribeiro; Melo, Ana Cláudia Moreira; Tiossi, Rodrigo

    2014-12-01

    The rehabilitation of edentulous maxillae is a complex procedure due to the involvement of esthetic and functional requirements. A trial maxillary denture can be used to identify the need for adequate upper lip support when replacing removable complete dentures by implant-fixed dental prostheses. This clinical report describes the outcome of the rehabilitation of an edentulous atrophic maxilla with unfavorable maxillomandibular relationship and deficient upper lip support. A trial denture was fabricated and used to diagnose the need for a prosthesis capable of restoring the upper lip support. The reduced upper lip support was also confirmed by a lateral cephalogram. The patient was rehabilitated by an implant-fixed dental prosthesis associated with an attachment-retained gingival prosthesis. The case presented shows that when loss of upper lip support is detected and the patient does not wish to undergo further surgical reconstruction procedure, the retention of a gingival prosthesis using a ball attachment is a satisfactory treatment option. © 2014 by the American College of Prosthodontists.

  11. Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses

    Jalil Ghanbarzadeh

    2015-01-01

    Conclusion: Within the limitations of this study, the marginal misfit of cement-retained FDPs increased continuously when the tightening torque increased. After cutting the connectors, the marginal misfit of the ANRs was higher than those of the straight abutment retainers.

  12. Maxillary implant-supported overdentures opposed by (partial) natural dentitions : A 5-year prospective case series study

    Boven, G. C.; Slot, J. W. A.; Raghoebar, G. M.; Vissink, A.; Meijer, H. J. A.

    2017-01-01

    The aim of this study was to assess the 5-year treatment outcome of maxillary implant-retained overdentures opposed by natural antagonistic teeth. Fifty consecutive patients received maxillary overdentures supported by six dental implants. Implants were placed in the anterior region, if enough bone

  13. Maxillary implant-supported overdentures opposed by (partial) natural dentitions: a 5-year prospective case series study.

    Boven, G C; Slot, J W A; Raghoebar, G M; Vissink, A; Meijer, H J A

    2017-12-01

    The aim of this study was to assess the 5-year treatment outcome of maxillary implant-retained overdentures opposed by natural antagonistic teeth. Fifty consecutive patients received maxillary overdentures supported by six dental implants. Implants were placed in the anterior region, if enough bone was present (n = 25 patients) Implant were placed in the posterior region if implant placement in the anterior region was not possible (n = 25 patients). Variables assessed included survival of implants, condition of hard and soft peri-implant tissues and patients' satisfaction. The five-year implant survival rate was 97·0% and 99·3%, and mean radiographic bone loss was 0·23 and 0·69 mm in the anterior and posterior group, respectively. Median scores for plaque, calculus, gingiva, bleeding and mean scores for pocket probing depth were low and stayed low. Patients' satisfaction after treatment was high in both groups. Within the limits of this 5-year study, it is concluded that six dental implants (placed in the anterior or posterior region) connected with a bar and opposed to natural antagonistic teeth result in acceptable results for clinical parameters and good outcomes for marginal bone level changes and patient satisfaction. © 2017 John Wiley & Sons Ltd.

  14. Full Contoured Tooth-Implant Supported 3-Pointic All-Ceramic Denture During Occlusal Load Transfer in Lateral Region

    Żmudzki J.

    2016-06-01

    Full Text Available Implant and a tooth supported dentures are avoided by dentists because of uneven distribution of occlusal loads between a stiffer implant and a more pliable tooth. The hypothesis was that a 3-point all-ceramic bridge supported on a natural second premolar tooth and a two-pieces typical implant bears safely mastication loads. The finite element analysis showed that the implant splinted by all-ceramic zirconium bridge with the second premolar was safe under lateral mastication load, but there was found an overload at wide zone of bone tissue around the implant under the load of 800 N. The patients can safely masticate, but comminution of hard food should be avoided and they should be instructed that after such an indiscretion they need to contact a dental professional, because, in spite of integrity of the prosthesis, the bone tissue around the implant may fail and there is a hazard of intrusion of the tooth.

  15. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

    Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku

    2011-11-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

  16. A generic methodology for the design of sustainable carbon dioxide utilization processes using superstructure optimization

    Frauzem, Rebecca; Gani, Rafiqul

    , including as an extractive agent or raw material. Chemical conversion, an important element of utilization, involves the use of carbon dioxide as a reactant in the production of chemical compounds [2]. However, for feasible implementation, a systematic methodology is needed for the design of the utilization......, especially chemical conversion, processes. To achieve this, a generic methodology has been developed, which adopts a three-stage approach consisting in (i) process synthesis, (ii) process design, and (iii) innovative and sustainable design [3]. This methodology, with the individual steps and associated...... methods and tools, has been developed and applied to carbon dioxide utilization networks. This work will focus on the first stage, process synthesis, of this three-stage methodology; process synthesis is important in determining the appropriate processing route to produce products from a selection...

  17. A generic methodology for processing route synthesis and design based on superstructure optimization

    Bertran, Maria-Ona; Frauzem, Rebecca; Sanchez-Arcilla, Ana Sofia

    2017-01-01

    a specially developed knowledge representation system, and (2) Super-O, a software interface that guides users through the formulation and solution of synthesis problems. Super-O transfers data between the different tools, including a library of generic models, representing a wide range of processing options...... are resolved and targets for improvement are identified through the use of integrated tools. In Stage 3, new alternatives are generated using the selected route and the previously identified targets. In addition to the various computer-aided tools, two special tools are presented: (1) a database employing...

  18. Possible superstructures of metallic ions in nonstoichiometric fullerites Mx C60

    Loktev, V.M.; Tatarenko, O.M.

    1993-01-01

    The ordered structures of alkali metal M=K,Rb,Cs atoms are considered in the M x C 60 systems for x<6 on the basis of symmetry analysis. Using the static concentration wave approach the x values and the corresponding vectors resulting in periodic structures are determined. The phase diagram that agrees qualitatively with the one observed experimentally is obtained. (author). 17 refs., 10 figs

  19. Superstructure development and optimization under uncertainty for design and retrofit of municipal wastewater treatment plants

    Bozkurt, Hande; Quaglia, Alberto; Gernaey, Krist

    2014-01-01

    n this contribution, an optimization - based approach is presented for optimal process selec tion and design for domestic wastewater treatment plant s (WWTP s ). In particular, we address the issue of uncertainties by formulating the WWTP design problem as a Stochastic Mixed Integer (Non) Linear ...

  20. Electrical conduction through surface superstructures measured by microscopic four-point probes

    Hasegawa, S.; Shiraki, I.; Tanabe, F.

    2003-01-01

    For in-situ measurements of the local electrical conductivity of well-defined crystal surfaces in ultra-high vacuum, we have developed two kinds of microscopic four-point probe methods. One involves a "four-tip STM prober," in which four independently driven tips of a scanning tunneling microscope...... (STM) are used for measurements of four-point probe conductivity. The probe spacing can be changed from 500 nm to 1 mm. The other method involves monolithic micro-four-point probes, fabricated on silicon chips, whose probe spacing is fixed around several mum. These probes are installed in scanning...

  1. Polymersomes with asymmetric membranes and self-assembled superstructures using pentablock quintopolymers resolved by electron tomography

    Haataja, J. S.; Houbenov, N.; Aseyev, V.; Fragouli, P.; Iatrou, H.; Sougrat, Rachid; Hadjichristidis, Nikolaos; Ikkala, O.

    2018-01-01

    Polystyrene-block-poly(1,4-isoprene)-block-poly(dimethyl siloxane)-block-poly(tert-butyl methacrylate)-block-poly(2-vinyl pyridine), PS-b-PI-b-PDMS-b-PtBMA-b-P2VP, self-assembles in acetone into polymersomes with asymmetric (directional) PI

  2. Structural transformation of biochar black carbon by C60 superstructure: Environmental implications

    Aqueous fullerene C60 nanoparticles (nC60) are frequently considered within the environmental engineering community as the aggregate of 60-carbon molecules. This study employed transmission electron microscopy (TEM) and x-ray diffraction (XRD) to demonstrate that nC60 formed via prolonged stirring ...

  3. The twofold superstructure of titanium(III) oxybromide at T = 17.5 K

    Palatinus, Lukáš; Schönleber, A.

    2005-01-01

    Roč. 61, - (2005), s. 147-148 ISSN 0108-2701 Institutional research plan: CEZ:AV0Z10100521 Keywords : spin-Peierls state * quantum magnet * cation-cation interaction Subject RIV: BM - Solid Matter Physics ; Magnet ism Impact factor: 0.777, year: 2005

  4. Monoclinic superstructure of Pr{sub 3}Rh{sub 4}Ge{sub 4}

    Vosswinkel, Daniel; Hoffmann, Rolf-Dieter; Greiwe, Magnus; Eul, Matthias; Poettgen, Rainer [Muenster Univ. (Germany). Inst. fuer Anorganische und Analytische Chemie

    2016-07-01

    Pr{sub 3}Rh{sub 4}Ge{sub 4} was synthesized by melting of the elements in an arc-melting furnace followed by annealing in a sealed tantalum ampoule in a muffle furnace. Structure refinement was based on temperature dependent single-crystal X-ray diffractometer data. At ambient temperature Pr{sub 3}Rh{sub 4}Ge{sub 4} adopts the U{sub 3}Ni{sub 4}Si{sub 4} type structure with strongly enhanced anisotropic displacement parameters for Rh1. Below 230 K additional reflections start to appear and at 110 K the structure could be described with the (3+1)D superspace group I2/m(α0γ)00; α=1/2, γ=1/2; (Z=2). This commensurately modulated structure could be refined with 1448 F{sup 2} values, 39 variables and residuals of wR=0.0417 for the main reflections and wR=0.1520 for the satellites of 1{sup st} order, [a=408.36(2), b=421.12(3) and c=2504.4(2) pm]. The commensurate description could be transformed to a 3D supercell with space group A2/m and Z=4: a=816.72(2), b=421.12(3), c=2537.5(1) pm, β=99.26(1) , 1448 F{sup 2} values, 69 variables and wR=0.0499. The relation of the U{sub 3}Ni{sub 4}Si{sub 4} type structure, the (3+1)D modulated and the 3D supercell is discussed on the basis of a group-subgroup scheme. Temperature dependent magnetic susceptibility data reveal Curie-Weiss paramagnetism with an experimental moment of 3.72(2) μ{sub B}/Pr atom and a Weiss constant of -12.6(5) K. No magnetic ordering is evident down to 3 K.

  5. Band gap narrowing of SnS2 superstructures with improved hydro-gen production

    Li, Guowei; Su, Ren; Rao, Jiancun; Rudolf, Petra; Blake, Graeme; de Groot, Robert; Besenbacher, Flemming; Palstra, Thomas

    2016-01-01

    Transition metal sulfides exhibit chemical and physical properties that are of much scientific and technological interest and can largely be attributed to their covalent bonding of 3d electrons. Hierarchical structures of these materials are suited for a broad range of applications in energy

  6. Life cycle assessment of a railway bridge: comparison of two superstructure designs

    Du, Guangli; Karoumi, Raid

    2013-01-01

    Railway bridges currently encounter the challenges of increasing the load capacity while the environmental sustainability should be achieved. However, it has been realised that the environmental assessment of railway bridges has not been integrated into the decision-making process, the standard g...

  7. Two superstructures of Ce{sub 3}Rh{sub 4}Ge{sub 4}

    Vosswinkel, Daniel; Hoffmann, Rolf-Dieter [Muenster Univ. (Germany). Inst. fuer Anorganische und Analytische Chemie; Svitlyk, Volodymyr [European Synchrotron Radiation Facility, Grenoble (France); and others

    2018-04-01

    Two different samples of Ce{sub 3}Rh{sub 4}Ge{sub 4} were synthesized from different starting compositions by melting of the elements in an arc-melting furnace followed by annealing sequences in a sealed tantalum ampoule in a muffle furnace. The structures of two different stacking variants were refined on the basis of temperature dependent single-crystal X-ray diffractometer data. At high temperature Ce{sub 3}Rh{sub 4}Ge{sub 4} adopts the U{sub 3}Ni{sub 4}Si{sub 4} type structure with strongly enhanced anisotropic displacement parameters for the Rh1 atoms. For the two different crystals, additional reflections start to appear at different temperatures. The first crystal showed additional reflections already at room temperature (stacking variant I) and the second one showed additional reflections emerging below 270 K (stacking variant II). Stacking variant I could be described with the (3+1)D superspace group I2/m(α0γ)00; α=1/2a*, γ=1/2c*; (Z=2), 1252 F{sup 2} values, 48 variables, wR=0.0306 for the main and wR=0.0527 for 440 1{sup st} order satellite reflections, similar to Pr{sub 3}Rh{sub 4}Ge{sub 4}. For stacking variant II the (3+1)D superspace group is Immm(α00)00s; α=1/2a*; (Z=2). The structure could be refined with 1261 F{sup 2} values, 53 variables and residuals of wR=0.0331 for the main reflections and wR=0.1755 (R1{sub obs}=0.0788) for the 1{sup st} order satellite reflections, [a=406.2(1), b=423.7(1) and c=2497.1(1) pm]. The commensurate description could be transformed to a three-dimensional (3D) supercell with space group Pnma and Z=4: a=812.5(1), b=423.7(1), c=2497.1(2) pm, 1261 F{sup 2} values, 69 variables and wR=0.0525. The relation of the U{sub 3}Ni{sub 4}Si{sub 4} type structure, the (3+1)D modulated and the 3D supercells are discussed on the basis of group-subgroup schemes. Ab initio electronic structure calculations are in line with the diffraction experiments, revealing the lowest total energy for the Pnma phase.

  8. Simulations of super-structure domain walls in two dimensional assemblies of magnetic nanoparticles

    Jordanovic, Jelena; Beleggia, Marco; Schiøtz, Jakob

    2015-01-01

    We simulate the formation of domain walls in two-dimensional assemblies of magnetic nanoparticles. Particle parameters are chosen to match recent electron holography and Lorentz microscopy studies of almost monodisperse cobalt nanoparticles assembled into regular, elongated lattices. As the parti......We simulate the formation of domain walls in two-dimensional assemblies of magnetic nanoparticles. Particle parameters are chosen to match recent electron holography and Lorentz microscopy studies of almost monodisperse cobalt nanoparticles assembled into regular, elongated lattices...... taking the role of the atomic spins. The coupling is, however, different. The superspins interact only by dipolar interactions as exchange coupling between individual nanoparticles may be neglected due to interparticle spacing. We observe that it is energetically favorable to introduce domain walls...... oriented along the long dimension of nanoparticle assemblies rather than along the short dimension. This is unlike what is typically observed in continuous magnetic materials, where the exchange interaction introduces an energetic cost proportional to the area of the domain walls. Structural disorder...

  9. Simulations of super-structure domain walls in two dimensional assemblies of magnetic nanoparticles

    Jordanovic, J.; Frandsen, C.; Beleggia, M.; Schiøtz, J.

    2015-01-01

    We simulate the formation of domain walls in two-dimensional assemblies of magnetic nanoparticles. Particle parameters are chosen to match recent electron holography and Lorentz microscopy studies of almost monodisperse cobalt nanoparticles assembled into regular, elongated lattices. As the particles are small enough to consist of a single magnetic domain each, their magnetic interactions can be described by a spin model in which each particle is assigned a macroscopic “superspin.” Thus, the magnetic behaviour of these lattices may be compared to magnetic crystals with nanoparticle superspins taking the role of the atomic spins. The coupling is, however, different. The superspins interact only by dipolar interactions as exchange coupling between individual nanoparticles may be neglected due to interparticle spacing. We observe that it is energetically favorable to introduce domain walls oriented along the long dimension of nanoparticle assemblies rather than along the short dimension. This is unlike what is typically observed in continuous magnetic materials, where the exchange interaction introduces an energetic cost proportional to the area of the domain walls. Structural disorder, which will always be present in realistic assemblies, pins longitudinal domain walls when the external field is reversed, and makes a gradual reversal of the magnetization by migration of longitudinal domain walls possible, in agreement with previous experimental results

  10. Bottom-up construction of a superstructure in a porous uranium-organic crystal

    Li, Peng; Vermeulen, Nicolaas A.; Malliakas, Christos D.; G?mez-Gualdr?n, Diego A.; Howarth, Ashlee J.; Mehdi, B. Layla; Dohnalkova, Alice; Browning, Nigel D.; O?Keeffe, Michael; Farha, Omar K.

    2017-04-20

    Bottom-up construction of highly intricate structures from simple building blocks remains one of the most difficult challenges in chemistry. We report a structurally complex, mesoporous uranium-based metal-organic framework (MOF) made from simple starting components. The structure comprises 10 uranium nodes and seven tricarboxylate ligands (both crystallographically nonequivalent), resulting in a 173.3-angstrom cubic unit cell enclosing 816 uranium nodes and 816 organic linkers—the largest unit cell found to date for any nonbiological material. The cuboctahedra organize into pentagonal and hexagonal prismatic secondary structures, which then form tetrahedral and diamond quaternary topologies with unprecedented complexity. This packing results in the formation of colossal icosidodecahedral and rectified hexakaidecahedral cavities with internal diameters of 5.0 nanometers and 6.2 nanometers, respectively—ultimately giving rise to the lowest-density MOF reported to date.

  11. Vacancy ordering and superstructure formation in dry and hydrated strontium tantalate perovskites: A TEM perspective

    Ashok, Anuradha M.; Haavik, Camilla; Norby, Poul

    2014-01-01

    Crystal structures of Sr4(Sr2Ta2)O11 and Sr4(Sr1.92Ta2.08)O11.12, synthesized by solid state reaction technique in dry and hydrated state have been studied mainly using Transmission Electron Microscopy. Due to the lesser ability of X-rays to probe details in oxygen sublattice, the change in crystal...... and corresponding unit cells of all the perovskites based on the ordering of oxygen vacancies is deduced. Crystal unit cells based on the observations are proposed with ideal atomic coordinates. Finally an attempt is made to explain the water uptake behaviour of these perovskites based on the proposed crystal...

  12. Lieb-Mattis ferrimagnetic superstructure and superparamagnetism in Fe-based double perovskite multiferroics

    Kuzian, R. O.; Laguta, Valentyn; Richter, J.

    2014-01-01

    Roč. 90, č. 13 (2014), "134415-1"-"134415-13" ISSN 1098-0121 R&D Projects: GA ČR GA13-11473S Institutional support: RVO:68378271 Keywords : multiferroics * superantiferromagnetism * DFT calculations Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.736, year: 2014

  13. Construction work of superstructure of twin harp bridge. Twin harp kyo jobuko no seko

    Sasaki, H.; Sato, Y.; Kanazawa, Y. (Sumitomo Construction Kajima Corp. Dopy Construction Co. Ltd. Nihon Koatsu Concrete Co. Ltd. Joint Venture, Tokyo (Japan)); Sema, M. (Sumitomo Construction Co. Ltd., Tokyo (Japan))

    1991-11-30

    Construction plan outline of PC cable stayed bridge with main tower having one pillar structure is introduced and this is the first type of bridge in Japan with three continuous span design. Construction was commenced on 7 July, 1989 and was completed on 8 August, 1991 at south east of Ashahikawa, Hokkaido. Construction outline is consisted of Principal specifications, general layout of structure, construction order and overall stage of the construction work. Main tower is described by its outline, jump system, installation of diagonal member anchorage device, formwork and concrete structure, and cross beam construction has included four parts which are outline, capital part, projected part construction, lateral span and closure part, and central control span and closure part. Outline, cable guard and erection work, cable work, work Procedure of cable taut construction using total taut method, tension adjustment of cable and grouting, for diagonal member are explained. The construction control items specific to cable stayed bridge are diagonal member tension control( control of applied tension, change of tension with time and test taut ) and camber control. Practical vibration test was carried out on March, 1991. 8 refs., 15 figs., 5 tabs.

  14. Surface characterization of the cement for retention of implant supported dental prostheses: In vitro evaluation of cement roughness and surface free energy

    Brajkovic, Denis; Antonijevic, Djordje; Milovanovic, Petar; Kisic, Danilo; Zelic, Ksenija; Djuric, Marija; Rakocevic, Zlatko

    2014-01-01

    Graphical abstract: - Highlights: • Surface free energy and surface roughness influence bacterial adhesion. • Bacterial colonization causes periimplantitis and implant loss. • Zinc-based, glass-ionomers and resin-cements were investigated. • Glass-ionomers-cements present the lowest values of surface free energy and roughness. • Glass-ionomer-cements surface properties result with reduced bacterial adhesion. - Abstract: Background: Material surface free energy and surface roughness strongly influence the bacterial adhesion in oral cavity. The aim of this study was to analyze these two parameters in various commercial luting agents used for cementation of implant restorations. Materials and methods: Zinc-based, glass-ionomers, resin modified glass-ionomer and resin-cements were investigated. Contact angle and surface free energy were measured by contact angle analyzer using Image J software program. Materials’ average roughness and fractal dimension were calculated based on Atomic Force Microscope topography images. Results: Zinc phosphate cements presented significantly higher total surface free energy and significantly lower dispersive component of surface free energy compared to other groups, while resin-cements showed significantly lower polar component than other groups. The surface roughness and fractal dimension values were statistically the highest in the zinc phosphate cements and the lowest for the glass-ionomers cements. Conclusion: Glass-ionomers-cements presented lower values of surface free energy and surface roughness than zinc phosphate and resin cements, indicating that their surfaces are less prone to biofilm adhesion. Practical implications: Within limitations of an in vitro trial, our results indicate that glass-ionomers-cements could be the cements of choice for fixation of cement retained implant restorations due to superior surface properties compared to zinc phosphate and resin cements, which may result in reduced plaque formation and presumably prevent periimplant infection

  15. Surface characterization of the cement for retention of implant supported dental prostheses: In vitro evaluation of cement roughness and surface free energy

    Brajkovic, Denis [Clinic for Dentistry, Department of Maxillofacial Surgery, Faculty of Medical Sciences, University of Kragujevac, Svetozara Markovica 69, 34000 Kragujevac (Serbia); Antonijevic, Djordje; Milovanovic, Petar [Laboratory for Anthropology, Institute of Anatomy, School of Medicine, University of Belgrade, Dr. Subotica 4/2, 11000 Belgrade (Serbia); Kisic, Danilo [Laboratory for Atomic Physics, Institute of Nuclear Sciences “Vinca”, University of Belgrade, Belgrade (Serbia); Zelic, Ksenija; Djuric, Marija [Laboratory for Anthropology, Institute of Anatomy, School of Medicine, University of Belgrade, Dr. Subotica 4/2, 11000 Belgrade (Serbia); Rakocevic, Zlatko, E-mail: zlatkora@vinca.rs [Laboratory for Atomic Physics, Institute of Nuclear Sciences “Vinca”, University of Belgrade, Belgrade (Serbia)

    2014-08-30

    Graphical abstract: - Highlights: • Surface free energy and surface roughness influence bacterial adhesion. • Bacterial colonization causes periimplantitis and implant loss. • Zinc-based, glass-ionomers and resin-cements were investigated. • Glass-ionomers-cements present the lowest values of surface free energy and roughness. • Glass-ionomer-cements surface properties result with reduced bacterial adhesion. - Abstract: Background: Material surface free energy and surface roughness strongly influence the bacterial adhesion in oral cavity. The aim of this study was to analyze these two parameters in various commercial luting agents used for cementation of implant restorations. Materials and methods: Zinc-based, glass-ionomers, resin modified glass-ionomer and resin-cements were investigated. Contact angle and surface free energy were measured by contact angle analyzer using Image J software program. Materials’ average roughness and fractal dimension were calculated based on Atomic Force Microscope topography images. Results: Zinc phosphate cements presented significantly higher total surface free energy and significantly lower dispersive component of surface free energy compared to other groups, while resin-cements showed significantly lower polar component than other groups. The surface roughness and fractal dimension values were statistically the highest in the zinc phosphate cements and the lowest for the glass-ionomers cements. Conclusion: Glass-ionomers-cements presented lower values of surface free energy and surface roughness than zinc phosphate and resin cements, indicating that their surfaces are less prone to biofilm adhesion. Practical implications: Within limitations of an in vitro trial, our results indicate that glass-ionomers-cements could be the cements of choice for fixation of cement retained implant restorations due to superior surface properties compared to zinc phosphate and resin cements, which may result in reduced plaque formation and presumably prevent periimplant infection.

  16. Passividade da estrutura metálica para próteses fixas implanto-suportadas = Passivity of metallic framework for implant-supported fixed prosthesis

    Stüker, Rafael Augusto

    2005-01-01

    Full Text Available Em virtude da freqüência cada vez maior de reabilitações implanto-suportadas, e de que esta modalidade de tratamento vem se mostrando extremamente eficaz na resolução de várias situações clínicas, foi realizada esta revisão literária com o objetivo de ressaltar questões relacionadas à passividade da estrutura metálica em próteses fixas sobre implantes. São descritos aspectos e alternativas relacionadas a alterações ósseas, assim como procedimentos clínicos e laboratoriais que podem influenciar na passividade de estruturas metálicas, esta que talvez seja o fator mais importante na determinação da longevidade tanto da restauração protética quanto dos implantes

  17. Prevalence of Peri-Implant Mucositis and Peri-Implantitis in Patients Treated with a Combination of Axial and Tilted Implants Supporting a Complete Fixed Denture

    Nicolò Cavalli

    2015-01-01

    Full Text Available Objectives. The aim of this retrospective study was to assess the incidence and prevalence of peri-implant mucositis and peri-implantitis in patients with a fixed full-arch prosthesis supported by two axial and two tilted implants. Materials and Methods. Sixty-nine patients were included in the study. Each patient received a fixed full-arch prosthesis supported by two mesial axial and two distal tilted implants to rehabilitate the upper arch, the lower arch, or both. Three hundred thirty-six implants for 84 restorations were delivered. Patients were scheduled for follow-up visits every 6 months in the first 2 years and yearly after. At each follow-up visit peri-implant mucositis and peri-implantitis were diagnosed if present. Results. The overall follow-up range was from 12 to 130 months (mean 63,2 months. Three patients presented peri-implantitis. The prevalence of peri-implant mucositis ranged between 0 and 7,14% of patients (5,06% of implants while the prevalence of peri-implantitis varied from 0 to 4,55% of patients (3,81% of implants. Conclusions. The prevalence and incidence of peri-implant mucositis and peri-implantitis are lower than most of the studies in literature. Therefore this kind of rehabilitation could be considered a feasible option, on the condition of adopting a systematic hygienic protocol.

  18. Establishing the maxillary occlusal plane as a requisite for placement of an immediate implant-supported fixed prosthesis in the mandible: a case report

    Milton Edson Miranda

    Full Text Available INTRODUCTION: In patients with Bruxism, the attrition can result in excessive occlusal wear that exceeds the compensatory mechanism and loss of occlusion vertical dimension occurs. OBJECTIVE: The purpose of this article is to show the importance of re-establishing an adequate occlusal plane for the non treated arch by means of a fixed acrylic overlay, compatible with the prosthetic treatment of the arch to be rehabilitated. An upper maxillary fixed acrylic overlay restored the patient’s occlusal plane in an appropriate vertical dimension of occlusion together with a fixed prosthesis in the mandible, supported by five dental implants. CONCLUSION: When there is severe wear due to dental attrition in one of the arches, it is important to re-establish the occlusal plane and compensation curves in conjunction with the prosthetic treatment of the arch to be rehabilitated.

  19. Evaluation of Stress Distribution of Mini Dental Implant-Supported Overdentures in Complete Cleft Palate Models: A Three-Dimensional Finite Element Analysis Study.

    Soğancı, Gökçe; Yazıcıoğlu, Hüseyin

    2016-01-01

    Mini dental implants could be an alternative treatment method for prosthetic treatment of edentulous cleft palate. The aim of this study was to analyze stress distribution around the cortical bone and different plans using a varied number of mini dental implants in edentulous unilateral complete cleft palates. Three edentulous maxillary models were modified to create unilateral complete cleft palates. Mini dental implants (2.4 × 15 mm) were located as two mini implants at the premolar region, four mini implants at the premolar and molar region, and six mini implants at the first premolar, second premolar, and first molar regions in the models, respectively. Mucosa, o-ring/ball attachments, and overdentures were simulated. Vertical and horizontal loads of 100 N were applied on both the right and left molar teeth of the overdenture for each model. Maximum and minimum principal stress values and the distribution at cortical bone around the implants and cleft palates were evaluated by finite element analysis. Stress values under vertical loads were lower than values under horizontal loadings for all models. Stress values were found to be lower in the first model than in the second and third models. The highest stress values were found around implants in the second model. The unilateral feature of a complete cleft pattern affected the stress distribution. Stresses occured mostly around implants when the overdenture was supported by six implants; however, the stress distribution around implants was low with two implants because of tissue support.

  20. The Biological Activity of Propolis-Containing Toothpaste on Oral Health Environment in Patients Who Underwent Implant-Supported Prosthodontic Rehabilitation

    Tadeusz Morawiec

    2013-01-01

    Full Text Available The soft and periodontal tissues surrounding dental implants are particularly susceptible to bacteria invasion and inflammatory reactions due to complex histological structures. This study was carried out to investigate the influence of a propolis-containing hygienic agent on selected oral health parameters, oral microflora, and the condition of periodontal health. Sixteen subjects who underwent an oral rehabilitation with dental implants were selected and randomly assigned into two groups, which received a newly formulated propolis-containing toothpaste (3% (CA or a negative control without an active ingredient (CC. Approximal plaque index (API, oral hygiene index (OHI, debris component, and sulcus bleeding index (SBI were assessed in three subsequent stages. During the first and last examinations, the swabs were employed for microbiological inoculation. Propolis-containing toothpaste was found to be distinctively effective in improving oral health and the occurrence of gingivitis triggered by dental plaque. The qualitative and quantitative changes in oral bacteria spectrum were observed. Antibacterial measures containing propolis might be used as a natural adjuvant to other active substances in individuals with a high risk of periodontal problems against pathogenic oral microflora.

  1. Oral rehabilitation of patients with Chediak-Higashi syndrome using zygoma and root form implant-supported fixed prostheses: A report of two patients.

    Alzoubi, Fawaz; Bedrossian, Edmond; Wong, Allen

    2016-12-01

    Chediak-Higashi syndrome (CH-S) is a rare genetic immunodeficiency disorder. Fewer than 500 individuals with CH-S have been reported worldwide in the past 20 years. The dental management of patients in whom CH-S has been diagnosed has been rarely reported and only in the form of a case report. All reports addressed the severe periodontal disease found in those patients, and most studies concluded that periodontal treatment had an unfavorable prognosis. As a result, complete edentulism at an early age because of severe periodontal disease is expected. The purpose of this report was to present 2 patients with CH-S seeking oral rehabilitation after early tooth loss and severe bone resorption as a manifestation of severe periodontal disease. The treatment used bilateral zygoma implants and an all-on-4 concept. The complications encountered and management with a 5-year post-surgery follow-up are also presented. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation.

    Rödiger, Matthias; Rinke, Sven; Ehret-Kleinau, Fenja; Pohlmeyer, Franziska; Lange, Katharina; Bürgers, Ralf; Gersdorff, Nikolaus

    2014-01-01

    PURPOSE: To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS: Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: 5.7°; customized-long, height: 6.79 mm, taper: 4.8°; customized-short, height: 4.31 mm, taper: 4.8°) were u...

  3. Evaluation of the Effect of Axial Wall Modification and Coping Design on the Retention of Cement-retained Implant-supported Crowns

    Derafshi, Reza; Ahangari, Ahmad Hasan; Torabi, Kianoosh; Farzin, Mitra

    2015-01-01

    Background and aims. Because of compromised angulations of implants, the abutments are sometimes prepared. The purpose of this study was to investigate the effect of removing one wall of the implant abutment on the retention of cement-retained crowns. Materials and methods. Four prefabricated abutments were attached to analogues and embedded in acrylic resin blocks. The first abutment was left intact. Axial walls were partially removed from the remaining abutments to produce abutments with three walls. The screw access channel for the first and second abutments were completely filled with composite resin. For the third and fourth abutments, only partial filling was done. Wax-up models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The copings of fourth abutment had an extension into the screw access channel. Copings were cemented with Temp Bond. The castings were removed from the abutment using an Instron machine, and the peak removal force was recorded. A one-way ANOVA was used to test for a significant difference followed by the pairwise comparisons. Results. The abutments with opened screw access channel had a significantly higher retention than the two other abutments. The abutment with removed wall and no engagement into the hole by the castings exhibited the highest retention. Conclusion. Preserving the opening of screw access channel significantly increases the retention where one of the axial walls of implant abutments for cement-retained restorations is removed during preparation. PMID:25973152

  4. Fully 3-dimensional digitally planned reconstruction of a mandible with a free vascularized fibula and immediate placement of an implant-supported prosthetic construction

    Schepers, Rutger H.; Raghoebar, Gerry M.; Vissink, Arjan; Lahoda, Lars U.; Van der Meer, W. Joerd; Roodenburg, Jan L.; Reintsema, Harry; Witjes, Max J.

    Background Reconstruction of craniofacial defects becomes complex when dental implants are included for functional rehabilitation. We describe a fully 3-dimensional (3D) digitally planned reconstruction of a mandible and immediate prosthetic loading with a fibula graft in a 2-step surgical approach.

  5. Changes in the midpalatal and pterygopalatine sutures induced by micro-implant-supported skeletal expander, analyzed with a novel 3D method based on CBCT imaging

    Daniele Cantarella

    2017-11-01

    Full Text Available Abstract Background Mini-implant-assisted rapid palatal expansion (MARPE appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME. Maxillary Skeletal Expander (MSE is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Methods Fifteen subjects (mean age of 17.2 years; range, 13.9–26.2 years were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher’s exact test was used. Results Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS and at posterior nasal spine (PNS was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P < 0.05. No significant differences were found in the magnitude and frequency of suture opening between males and females. Correlation between age and suture opening was negligible (R 2 range, 0.3–4.2%. Conclusions Midpalatal suture was successfully split by MSE in late adolescents, and the opening was almost perfectly parallel in a sagittal direction. Regarding the extent of transverse asymmetry of the split, on average one half of ANS moved more than the contralateral one by 1.1 mm. Pterygopalatine suture was split in its lower region by MSE, as the pyramidal process was pulled out from the pterygoid process. Patient gender and age had a negligible influence on suture opening for the age group considered in the study.

  6. Correction of a mandibular asymmetry after fibula reconstruction using a custom-made polyetheretherketone (PEEK) onlay after implant supported occlusal rehabilitation.

    Berrone, M; Aldiano, C; Pentenero, M; Berrone, S

    2015-10-01

    This study describes an unusual case of mandibular asymmetry after fibula free flap reconstruction in a young man following major facial trauma that was corrected using a custom-made polyetheretherketone prosthesis. There is little information in the literature on the use of alloplasts to correct mandibular asymmetry as interest in 'aesthetic re-modelling' has traditionally focused on nasal, zygomatic and chin regions. This report demonstrates that this technique can be used successfully to address selected cases of mandibular asymmetry.

  7. Rehabilitación implantosoportada en el colgajo libre de peroné Implant-supported rehabilitation using the fibula free flap

    C. Navarro Cuéllar

    2006-10-01

    Full Text Available El colgajo de peroné ha demostrado ser el más versatil para la reconstrucción oromandibular, gracias a la gran longitud ósea que podemos utilizar y a la posibilidad de incorporar una amplia paleta cutánea para cobertura de tejidos blandos intraorales. El uso de implantes dentales osteointegrados proporciona un importante método terapéutico para la rehabilitación oral de estos pacientes. Los implantes osteointegrados proporcionan la forma más rígida de estabilización protésica para soportar las fuerzas masticatorias. Estos implantes pueden ser insertados de forma inmediata o diferida. A la hora de utilizar el colgajo libre de peroné realizamos la implantología de forma diferida a los 6-12 meses debido a la gran cantidad de material de osteosíntesis necesaria para la fijación del colgajo. Cuatro o seis meses después, cuando el proceso de osteointegración ha ocurrido, los implantes son cargados con una rehabilitación dental. Analizamos 12 casos de reconstrucción mandibular con colgajo libre de peroné y su rehabilitación estética y funcional con implantes osteointegrados y un seguimiento mínimo de 2 años. Se han colocado un total de 56 implantes, presentando todos ellos excepto uno, una correcta osteointegración. Todos estos pacientes han recuperado la función masticatoria, y mejorado de forma considerable la competencia labial, la continencia salival, la pronunciación y la armonía facial.Free fibula flap has proved to be one of the most versatile for oromandibular reconstruction due to the available length of bone and the possibility of incorporating a long skin paddle to cover intraoral soft tissues. The use of osseointegrated dental implants is an important technique for the oral rehabilitation of these patients. Osseointegrated implants provide the most rigid prosthetic stabilization available to withstand masticatory forces.These implants can be placed immediately or in a second time procedure.In our case, implantation in the fibula free flap is done after 6-12 months because of the large amount of osteosynthesis material required forthe fixation of the flap. Four or six months later, when osseointegration has taken place, the implants are loaded with a dental rehabilitation. We analize 12 cases of mandibular reconstruction with fibula free flap and their aesthetic and functional rehabilitation with osseointegrated implants with a 2 year follow up Fifty-six dental implants were placed developing all of them but one a correct osseointegration. All these patients recovered masticatory function and underwent a considerable improvement in labial competence, salival continence, speech articulation and facial harmony.

  8. Evaluation of fit of cement-retained implant-supported 3-unit structures fabricated with direct metal laser sintering and vacuum casting techniques.

    Oyagüe, Raquel Castillo; Sánchez-Turrión, Andrés; López-Lozano, José Francisco; Montero, Javier; Albaladejo, Alberto; Suárez-García, María Jesús

    2012-07-01

    This study evaluated the vertical discrepancy of implant-fixed 3-unit structures. Frameworks were constructed with laser-sintered Co-Cr, and vacuum-cast Co-Cr, Ni-Cr-Ti, and Pd-Au. Samples of each alloy group were randomly luted in standard fashion using resin-modified glass-ionomer, self-adhesive, and acrylic/urethane-based cements (n = 12 each). Discrepancies were SEM analyzed. Three-way ANOVA and Student-Newman-Keuls tests were run (P Laser-sintered structures achieved the best fit per cement tested. Within each alloy group, resin-modified glass-ionomer and acrylic/urethane-based cements produced comparably lower discrepancies than the self-adhesive agent. The abutment position did not yield significant differences. All misfit values could be considered clinically acceptable.

  9. Changes in the midpalatal and pterygopalatine sutures induced by micro-implant-supported skeletal expander, analyzed with a novel 3D method based on CBCT imaging.

    Cantarella, Daniele; Dominguez-Mompell, Ramon; Mallya, Sanjay M; Moschik, Christoph; Pan, Hsin Chuan; Miller, Joseph; Moon, Won

    2017-11-01

    Mini-implant-assisted rapid palatal expansion (MARPE) appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME). Maxillary Skeletal Expander (MSE) is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Fifteen subjects (mean age of 17.2 years; range, 13.9-26.2 years) were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher's exact test was used. Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS) and at posterior nasal spine (PNS) was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS) moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P < 0.05). No significant differences were found in the magnitude and frequency of suture opening between males and females. Correlation between age and suture opening was negligible (R 2 range, 0.3-4.2%). Midpalatal suture was successfully split by MSE in late adolescents, and the opening was almost perfectly parallel in a sagittal direction. Regarding the extent of transverse asymmetry of the split, on average one half of ANS moved more than the contralateral one by 1.1 mm. Pterygopalatine suture was split in its lower region by MSE, as the pyramidal process was pulled out from the pterygoid process. Patient gender and age had a negligible influence on suture opening for the age group considered in the study.

  10. A sectional-splinting technique for impressing multiple implant units by eliminating the use of an open tray

    Suryakant C. Deogade

    2014-01-01

    Full Text Available Since the inception of root form implant dentistry by P-I Branemark in the early 1980′s, so many technical advances have been put forward by several authors. However, the open tray impression technique is still performed for impressing multiple implant fixtures as it was first described in the original Branemark procedure manual. The most critical aspect for a successful implant-supported restoration is the passive and an accurate fit of superstructures to avoid preload and loading stresses. Splinting impression technique in multiple implants has gained popularity. Auto-polymerizing acrylic resin is among the most routinely practiced splinting material for multiple implant units. However, unfortunately, it exhibits shrinkage, which makes an impression quite inaccurate. This case report presents the solution to minimize the shrinkage of resin by utilizing sectional-splinting technique as advocated in the previous implant literature.

  11. In Situ Fluorine Doping of TiO2 Superstructures for Efficient Visible-Light Driven Hydrogen Generation.

    Zhang, Peng; Tachikawa, Takashi; Fujitsuka, Mamoru; Majima, Tetsuro

    2016-03-21

    With the aid of breakthroughs in nanoscience and nanotechnology, it is imperative to develop metal oxide semiconductors through visible light-driven hydrogen generation. In this study, TiOF2 was incorporated as an n-type F-dopant source to TiO2 mesocrystals (TMCs) with visible-light absorption during the topotactic transformation. The crystal growth, structural change, and dynamic morphological evolution, from the initial intermediate NH4 TiOF3 to HTiOF3, TiOF2, and F-doped TMCs, were verified through in situ temperature-dependent techniques to elucidate the doping mechanism from intermediate TiOF2. The visible-light efficiencies of photocatalytic hydrogen were dependent on the contents of the dopant as compared with the pure TMC and a controled reference. Using femtosecond time-resolved diffuse reflectance spectroscopy, the charge-transfer dynamics were monitored to confirm the improvement of charge separation after doping. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Laser induced local structural and property modifications in semiconductors for electronic and photonic superstructures - Silicon carbide to graphene conversion

    Yue, Naili

    Graphene is a single atomic layer two-dimensional (2D) hexagonal crystal of carbon atoms with sp2-bonding. Because of its various special or unique properties, graphene has attracted huge attention and considerable interest in recent years. This PhD research work focuses on the development of a novel approach to fabricating graphene micro- and nano-structures using a 532 nm Nd:YAG laser, a technique based on local conversion of 3C-SiC thin film into graphene. Different from other reported laser-induced graphene on single crystalline 4H- or 6H- SiC, this study focus on 3C-SiC polycrystal film grown using MBE. Because the SiC thin film is grown on silicon wafer, this approach may potentially lead to various new technologies that are compatible with those of Si microelectronics for fabricating graphene-based electronic, optoelectronic, and photonic devices. The growth conditions for depositing 3C-SiC using MBE on Si wafers with three orientations, (100), (110), and (111), were evaluated and explored. The surface morphology and crystalline structure of 3C-SiC epilayer were investigated with SEM, AFM, XRD, μ-Raman, and TEM. The laser modification process to convert 3C-SiC into graphene layers has been developed and optimized by studying the quality dependence of the graphene layers on incident power, irradiation time, and surface morphology of the SiC film. The laser and power density used in this study which focused on thin film SiC was compared with those used in other related research works which focused on bulk SiC. The laser-induced graphene was characterized with μ-Raman, SEM/EDS, TEM, AFM, and, I-V curve tracer. Selective deposition of 3C-SiC thin film on patterned Si substrate with SiO2 as deposition mask has been demonstrated, which may allow the realization of graphene nanostructures (e.g., dots and ribbons) smaller than the diffraction limit spot size of the laser beam, down to the order of 100 nm. The electrical conductance of directly written graphene micro-ribbon (< 1 μm) was measured via overlaying two micro-electrodes using e-beam lithography and e-beam evaporation. The crystalline quality (stacking order, defect or disorder, strain, crystallite size, etc.) of laser-induced graphene was analyzed using Raman spectroscopy through the comparison with pristine natural graphite and CVD-grown monolayer graphene on SiO2/Si and other substrates. The experimental results reveal the feasibility of laser modification techniques as an efficient, inexpensive, and versatile (any shape and location) means in local synthesis of graphene, especially in patterning graphene nanostructures. Different from other laser induced graphene research works, which were concentrated on bulk SiC wafers, this PhD research work focuses on thin film SiC grown on Si (111) for the first time.

  13. Intralayer Cation Ordering in a Brownmillerite Superstructure: Synthesis, Crystal, and Magnetic Structures of Ca2FeCoO5

    Ramezanipour, Farshid; Greedan, John E.; Grosvenor, Andrew; Britten, James; Cranswick, Lachlan M.D.

    2010-01-01

    The synthesis, crystal, and magnetic structures and the bulk magnetic properties of Ca2FeCoO5, a brownmillerite type oxide, are presented. The crystal structure, solved and refined from single crystal X-ray and powder neutron diffraction data, is described in Pbcm with cell parameters, a = 5.3652(3), b = 11.0995(5), c = 14.7982(7) . Thus, one axis, b in this setting, is doubled in comparison with the standard brownmillerite structure description giving rise to two sets of octahedral and tetrahedral sites. Aided by the strong scattering contrast between Fe and Co for neutrons, a nearly perfect intralayer cation site ordering, not observed for any brownmillerite before, is detected in the tetrahedral layers. There is a lesser degree of cation site ordering in the octahedral sites. Overall, the Fe/Co site ordering is of the NaCl type both within and between the tetrahedral and octahedral layers. There are also both intra- and interlayer ordering of tetrahedral chain orientations. The left- and right-handed orientations alternate within each tetrahedral layer as well as between the closest tetrahedral layers. The occurrence of the rare Pbcm space group in Ca2FeCoO5 is not consistent with a recently proposed structure-field map for brownmillerite oxides. The magnetic structure is G-type antiferromagnetic, with preferred orientation of magnetic moments parallel to the longest axis between 3.8 K to 100 K which switches to the shortest axis between 225 K and 550 K. The neutron diffraction data indicate different site specific ordering temperatures at about 450(5) K and 555(5) K. The refined ordered moments at 3.8 K are somewhat smaller than expected for Fe3+ and Co3+(high spin) but are similar to those found in Sr2FeCoO5. There is evidence for spin canting from isothermal magnetization data that shows well pronounced hystereses and remnant magnetizations at 5 K and 200 K.

  14. Rapid visualization of fingerprints on various surfaces using ZnO superstructures prepared via simple combustion route

    N.H. Deepthi

    2018-03-01

    Full Text Available A simple solution combustion route has been used to prepare ZnO nanopowders (NPs using different barbiturates (Barbituric acid, 1, 3-dimethyl barbiturates and 2-thiobarbiturates as fuels. The obtained product was well characterized by powder X-ray diffraction (PXRD, scanning electron microscope (SEM, ultraviolet-visible Spectroscope (UV-Vis and Photoluminescence (PL. The PXRD results confirm the hexagonal phase of the material. The detailed structural analysis is performed by Rietveld refinement method. The energy band gap of NPs is found to be in the range of 3.31 - 3.49 eV. The growth mechanism for the formation of 3D micro-architectures is discussed in detail. The PL emission spectrum shows a broad emission peak at 502 nm upon an 406 nm excitation wavelength. The ZnO NPs can be used for the visualization of latent finger prints (LFPs under normal light on various porous and non-porous surfaces. In this case, the visualized LFPs are found to be excellent compared to the commercially available powders. Keywords: Zinc oxide, Barbiturates, Photoluminescence, Latent fingerprint

  15. Nucleation and temperature-driven phase transitions of silicene superstructures on Ag(1 1 1)

    Grazianetti, C; Chiappe, D; Cinquanta, E; Fanciulli, M; Molle, A

    2015-01-01

    Silicene grown on Ag(1 1 1) is characterized by several critical parameters. Among them, the substrate temperature plays a key role in determining the morphology during growth. However, an unexpected important role is also equally played by the post-deposition annealing temperature which determines the self-organization of silicene domains even in the submonolayer coverage regime and consecutive transitions between silicene with different periodicity. These temperature-driven phase transitions can be exploited to select the desired majority silicene phase, thus allowing for the manipulation of silicene properties. (paper)

  16. Finite Element Analysis of the Effect of Superstructure Materials and Loading Angle on Stress Distribution around the Implant

    Jafari K

    2014-12-01

    Full Text Available Statement of Problem: A general process in implant design is to determine the reason of possible problems and to find the relevant solutions. The success of the implant depends on the control technique of implant biomechanical conditions. Objectives: The goal of this study was to evaluate the influence of both abutment and framework materials on the stress of the bone around the implant by using threedimensional finite element analysis. Materials and Methods: A three-dimensional model of a patient’s premaxillary bone was fabricated using Cone Beam Computed Tomography (CBCT. Then, three types of abutment from gold, nickel-chromium and zirconia and also three types of crown frame from silver-palladium, nickel-chromium and zirconia were designed. Finally, a 178 N force at angles of zero, 30 and 45 degrees was exerted on the implant axis and the maximum stress and strain in the trabecular, cortical bones and cement was calculated. Results: With changes of the materials and mechanical properties of abutment and frame, little difference was observed in the level and distribution pattern of stress. The stress level was increased with the rise in the angle of pressure exertion. The highest stress concentration was related to the force at the angle of 45 degrees. The results of the cement analysis proved an inverse relationship between the rate of elastic modulus of the frame material and that of the maximum stress in the cement. Conclusions: The impact of the angle at which the force was applied was more significant in stress distribution than that of abutment and framework core materials.

  17. Insights into the multi-equilibrium, superstructure system based on β-cyclodextrin and a highly water soluble guest.

    De Paula, Elgte Elmin B; De Sousa, Frederico B; Da Silva, Júlio César C; Fernandes, Flaviana R; Melo, Maria Norma; Frézard, Frédéric; Grazul, Richard M; Sinisterra, Rubén D; Machado, Flávia C

    2012-12-15

    Pentamidine isethionate (PNT) is an antiprotozoal active in many cases of leishmaniasis, despite the present limitations including high toxicity and parenteral administration. In the present work, a PNT encapsulation strategy into β-cyclodextrin cavity at 1:1 and 2:1 (βCD:PNT) molar ratios was used in order to improve the drug's physical and chemical properties. Combining thermodynamic and structural approaches such as isothermal titration calorimetry (ITC), electrospray ionization mass spectrometry (ESI-MS) and nuclear magnetic resonance ((1)H NMR, and ROESY) the inclusion process and the thermodynamics parameters were identified. ITC and ESI-MS experimental data suggest the simultaneous formation of different supramolecular complexes in solution. Moreover, NMR data are in accordance with these results, suggesting a deep inclusion of PNT into the βCD cavity, through correlations observed in 2D ROESY contour maps. The systems were also characterized by FTIR, TG/DTA and SEM. These techniques indicate the formation of inclusion complex in the solid state. In vivo PNT activity was evaluated orally in mice. The inclusion complex showed a significant reduction of parasite load compared to free PNT. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Performance comparison of 0/π- and ± π/2-phase-shifted superstructured Fiber Bragg grating en/decoder.

    Dai, Bo; Gao, Zhensen; Wang, Xu; Kataoka, Nobuyuki; Wada, Naoya

    2011-06-20

    We compare the performances of the 0/π-phase-shifted SSFBG (0/π-SSFBG) and the ± π/2-phase-shifted SSFBG (± π/2-SSFBG) en/decoders in the three aspects: the security, coding and system performances. In terms of the security performance, we evaluate the security performance by the investigation on the encoded waveform of both encoders. We also propose and demonstrate the code extraction technique for the ± π/2-SSFBG encoder when input pulse has large pulse width. Then, we analyze the coding performance of these two kinds of en/decoders by the calculation of autocorrelation and cross-correlation with sets of 31-chip, 63-chip and 127-chip Gold codes. Furthermore, we propose and demonstrate the hybrid use of both en/decoders. To demonstrate the performance of both en/decoders and the hybrid use in the different systems, we employ four 31-chip 640 Gchip/s 0/π-SSFBG and ± π/2-SSFBG en/decoders in the 4-user 10 Gbps/user on-off keying and differential phase-shift keying OCDMA systems.

  19. On-Particle Rolling Circle Amplification-Based Core-Satellite Magnetic Superstructures for MicroRNA Detection

    Tian, Bo; Qiu, Zhen; Ma, Jing

    2018-01-01

    -specific nuclease in the presence of target microRNA, resulting in a release of MNPs that can be quantified in an optomagnetic sensor. The proposed biosensor has a simple mix-separate-measure strategy. For let-7b detection, the proposed biosensor offers a wide linear detection range of approximately 5 orders...

  20. Comparative design of the superstructure of timber bridges, using norm np 005 - 2003 and provisions of european standards

    Chiotan Corina

    2015-12-01

    Full Text Available The norms and standards for design of timber bridges, as well as other structures built from this material, were obsolete, design standards that were used dated from 1978 to 1980. The introduction of European Standards has created a new legislative framework in the field of designing and building timber bridges. Currently the design of such constructions use Norm NP 005-2003 and SR EN 1995-1-1: 2004 Eurocode 5: Design of timber structures. Part 1-1: General. Common rules and rules for buildings, SR EN 1995-2: 2005 Eurocode 5: Design of timber structures. Part 2: Bridges, along with their national annexes. The aim of this paper is to analyze the design of the beams for timber bridges in parallel, using on one hand Norm NP 005 - 2003, and on the other hand provisions of European standards. The design requirements for both norms as well as the results of a case study for a structural element of a timber bridge will be presented.

  1. Assessment of Superstructure Ice Protection as Applied to Offshore Oil Operations Safety: Ice Protection Technologies, Safety Enhancements, and Development Needs

    2009-04-01

    concrete to crack , encouraging freeze-thaw damage, corrosion damage, and possible struc- tural failure (Rangaraju et al. 2006). TRL: 8-9. COTS...CRREL TR 09-4 62 The acetate-based deicers cause alkali-silica reactions in concrete, which leads to swelling and cracking . Current Acquisition Cost...be investi- gated. Marine Technology Transfer Needs: Metal components are steel and should be enamelized , coated with ceramic, or coated with a

  2. Assessment of Superstructure Ice Protection as Applied to Offshore Oil Operations Safety: Problems, Hazards, Needs, and Potential Transfer Technologies

    2008-09-01

    factor. The Rowan Gorilla I jack-up sank during a tow in a severe North Atlantic storm in December 1988. Severe seas, and not icing, was the suspected...Papineau, J., n.d., Anatomy of High Wind Events Along Alaska’s North Slope. National Weather Service, Anchorage, AK. (http://pafc.arh.noaa.gov/papers

  3. A software prototype for assessing the reliability of a concrete bridge superstructure subjected to chloride-induced reinforcement corrosion

    Schneider, Ronald; Thöns, Sebastian; Fischer, Johannes

    2014-01-01

    state of the box girder and a structural model for evaluating the overall system reliability. The condition model is based on a dynamic Bayesian network (DBN) model which considers the spatial variation of the corrosion process. Inspection data are included in the calculation of the system reliability...

  4. Strategic structure matrix: A framework for explaining the impact of superstructure organizations on the diffusion of wind energy infrastructure

    Tang, Amy; Taylor, John E.; Mahalingam, Ashwin

    2013-01-01

    Increasing the use of renewables in the global energy mix has become a top priority for policy makers. In this paper, we use a diffusion theory based approach to analyze the impact of government initiatives on the development of wind energy infrastructure focusing on the specific case of wind energy diffusion in India. We propose a new framework—the strategic structure matrix—as a way to characterize the strategic focus and analyze the effectiveness of different initiatives to increase wind power diffusion. We apply the matrix to explain the different pace and paths of wind energy growth observed in five Indian states: Tamil Nadu, Gujarat, Maharashtra, Andhra Pradesh, and Karnataka. Our findings suggest the importance of a comprehensive approach that includes multiple strategies across initiatives, local regulatory measures, and supply-side incentives. - Highlights: • A new framework—the Strategic Structure Matrix—is proposed. • It characterizes strategic initiatives designed to promote innovation diffusion. • The matrix was validated using case study data on wind power diffusion in India. • The matrix can help shape government policies to improve RET diffusion

  5. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 3, 0.03 Superstructure

    1993-05-01

    General information is presented on asset determinant factor/CAS profile codes/CAS cost process; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for beams; pre-engineered building systems; floors; roof structure; stairs; and fireproofing.

  6. Reestablishment of the condyle-fossa and maxillomandibular relationships using a flat occlusal plane splint and implant-supported denture: case report with a 2-year follow-up

    MICELLI, Ana Lígia Piza; BUARQUE E SILVA, Wilkens Aurélio; ANDRADE E SILVA, Frederico; BUARQUE E SILVA, Lígia Luzia; ALVES, Josué Nogueira; CASSELLI, Denise de Sa Maia

    2015-01-01

    When the shape, structure, and/or function of one of the parts of the components of the stomatognathic system change, structural and physiological changes also occur to absorb or compensate the consequent loads. Hence, an insightful rehabilitation of this type of patient involves essential procedures, such as: correct orientation of the occlusal plane, determination of the vertical dimension of occlusion, and a stable and healthy maxillomandibular relationship, since the nonobservance of thes...

  7. Stresses in implant-supported overdentures with bone resorption: a 3-D finite element analysis = Tensões em sobredentaduras com reabsorção óssea: análise por elementos finitos tridimensional

    Mariano, Luiz Oscar Honorato

    2012-01-01

    Conclusão: Os resultados sugerem que a perda óssea periimplantar aumenta a concentração de tensões nos implantes, pilares e osso marginal independentemente da reabsorção óssea na crista distal

  8. Satisfaction level and masticatory performance of patient rehabilitated with implant-supported overdentures = Nível de satisfação e performance mastigatória de pacientes reabilitados com sobredentaduras suportada por implantes

    Pocztaruk, Rafael de Liz

    2009-01-01

    Full Text Available Objetivo: Comparar o nível de satisfação e a performance mastigatória dos indivíduos com dentição normal e pacientes reabilitados com uma sobredentadura suportada por implantes com dois tipos de conectores diferentes, sistema de retenção bola e barra. Metodologia: Vinte e quatro indivíduos participaram do estudo, sendo 12 pacientes desdentados e 12 indivíduos dentados totais. Os desdentados receberam dois implantes e novas dentaduras, superiores e inferiores. Três meses depois da primeira fase cirúrgica, a dentadura inferior foi conectada aos implantes através do sistema bola. Dois meses depois, uma nova sobredentadura inferior foi realizada, porém desta vez conectado através do sistema barra-clipe. O nível de satisfação (OHIP-EDENT adaptado e escala verbal de medição e a performance mastigatória (mastigação por 40 ciclos mastigatórios foram medidas em vários momentos do tratamento, com as dentaduras antigas, novas não conectadas por implantes, e depois de ter conectado a sobredentadura pelo sistema bola e barra-clipe. O teste de Friedman e o teste qui-quadrado foram aplicado para analisar os resultados. Resultados: O nível de satisfação e a performance mastigatória melhoraram significativamente após a reabilitação com os implantes. Nenhuma diferença foi observada entre as sobredentaduras com sistema bola e barra-clipe. Entretanto, a performance mastigatória ainda permaneceu significativamente menor que a performance dos indivíduos dentados. Conclusão: A reabilitação de pacientes edêntulos reabilitados com sobredentadura com bola ou barra-clipe melhora tanto o nível de satisfação, quanto à performance mastigatória, porém ainda abaixo do nível dos indivíduos com dentição normal

  9. Marginal bone-level alterations of loaded zirconia and titanium dental implants: an experimental study in the dog mandible.

    Thoma, Daniel S; Benic, Goran I; Muñoz, Fernando; Kohal, Ralf; Sanz Martin, Ignacio; Cantalapiedra, Antonio G; Hämmerle, Christoph H F; Jung, Ronald E

    2016-04-01

    The aim was to test whether or not the marginal bone-level alterations of loaded zirconia implants are similar to the bone-level alterations of a grade 4 titanium one-piece dental implant. In six dogs, all premolars and the first molars were extracted in the mandible. Four months later, three zirconia implants (BPI, VC, ZD) and a control titanium one-piece (STM) implant were randomly placed in each hemimandible and left for transmucosal healing (baseline). Six months later, CAD/CAM crowns were cemented. Sacrifice was scheduled at 6-month postloading. Digital X-rays were taken at implant placement, crowns insertion, and sacrifice. Marginal bone-level alterations were calculated, and intra- and intergroup comparisons performed adjusted by confounding factors. Implants were successfully placed. Until crown insertion, two implants were fractured (one VC, one ZD). At sacrifice, 5 more implants were (partly) fractured (one BPI, four ZD), and one lost osseointegration (VC). No decementation of crowns occurred. All implant systems demonstrated a statistically significant (except VC) loss of marginal bone between baseline and crown insertion ranging from 0.29 mm (VC; P = 0.116) to 0.80 mm (ZD; P = 0.013). The estimated marginal bone loss between baseline and 6 months of loading ranged between 0.19 mm (BPI) and 1.11 mm (VC), being statistically significant for STM and VC only (P implants and control implants (STM vs. BPI P = 0.007; vs. VC P = 0.001; vs. ZD P = 0.011). Zirconia implants were more prone to fracture prior to and after loading with implant-supported crowns compared to titanium implants. Individual differences and variability in the extent of the bone-level changes during the 12-month study period were found between the different implant types and materials. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Bottom-up-then-up-down Route for Multi-level Construction of Hierarchical Bi2S3 Superstructures with Magnetism Alteration

    Wei, Chengzhen; Wang, Lanfang; Dang, Liyun; Chen, Qun; Lu, Qingyi; Gao, Feng

    2015-01-01

    A bottom-up-then-up-down route was proposed to construct multi-level Bi2S3 hierarchical architectures assembled by two-dimensional (2D) Bi2S3 sheet-like networks. BiOCOOH hollow spheres and flower-like structures, which are both assembled by 2D BiOCOOH nanosheets, were prepared first by a “bottom-up” route through a “quasi-emulsion” mechanism. Then the BiOCOOH hierarchical structures were transferred to hierarchical Bi2S3 architectures through an “up-down” route by an ion exchange method. The obtained Bi2S3 nanostructures remain hollow-spherical and flower-like structures of the precursors but the constructing blocks are changed to 2D sheet-like networks interweaving by Bi2S3 nanowires. The close matching of crystal lattices between Bi2S3 and BiOCOOH was believed to be the key reason for the topotactic transformation from BiOCOOH nanosheets to 2D Bi2S3 sheet-like nanowire networks. Magnetism studies reveal that unlike diamagnetism of comparative Bi2S3 nanostructures, the obtained multi-level Bi2S3 structures display S-type hysteresis and ferromagnetism at low field which might result from ordered structure of 2D networks. PMID:26028331

  11. Neutron und X-ray diffraction study on the superstructure of a sodium-rich low plagioclase An sub(16.5)

    Joswig, W.; Korekawa, M.

    1977-01-01

    Neutron and X-ray diffraction experiments had been carried out on a sodium-rich low plagioclase Ansub(16.5) from Sultan Hamud, Kenya. In constrast to previous work very weak (g) reflections (satellites) for all reflections Okl, except reflections 001, could be observed. It is shown that the neutron diffraction method is advantageous to study on submicroscopic periodic domain structure as reported here. (orig.) [de

  12. Determination of superstructures and magnetic structures in the system (Fe,Mn)(Nb,Ta)2O6 with elastic neutron scattering experiments

    Klein, S.

    1976-01-01

    The aim of this work was to study the magnetic structures of the Trirutil FeTa 2 O 6 and the Columbit MnTa 2 O 6 . A further question was the influence of the nonmagnetic positive Ions on the developing magnetic structure. One example is the mixed-crystal series Mn(Nb,Ta) 2 O 6 . The different magnetic structures of FeNb 2 O 6 and MnNb 2 O 6 , having the same chemical structure, causes the existence of a transition region between these two magnetic structures. Neutron diffration is a well-suited method to investigate the character of these concentration-dependent phase tansitions. All experiments have been performed with elastic neutrons, and a new set-up for measurrement of low temperatures has been used. For the evaluaion of these data two computer programs are developed. (orig./HPOE) [de

  13. Design and construction of superstructure in prestressed concrete cable-stayed bridge. ; Aomori Bay Bridge. PC shachokyo jobuko no sekkei to seko. ; Aomori Bay Bridge

    Ishibashi, T.; Fujimori, S.; Oba, M.; Tsuyoshi, T. (East Japan Railway Co., Tokyo (Japan))

    1991-12-01

    Aomori Bay Bridge is a 1,219m long elevated bridge, a part of No.2 Bay Highway of 1,993m in total length crossing over Aomori railway station which was planned in ordecr to integrate the port facilities of Aomori Harbor and expedite cargo traffic smoothly. Of this Bay Bridge, its main bridge portion crossing over Aomori railway station and the sea area was planned as a continuous prestressed concrete cable-stayed bridge of 498m in total length and consisting of three portions including the central portion in which the main span between the central bridge piers was 240m. It is scheduled to open in the summer of 1992. With regard to the design of this bridge, special care for the view of the bridge has been taken covering from the structure style to the accessories. For this bridge, a large scale underground continuous wall solid base with a box-shaped section consisting of 6 chambers was adopted for the base of a main tower. It has the cantilever suspension structure of the wide girder with the inverted Y-shaped pylons. For its stav cable, was adopted a large capacity stay cable with standard tensile strength of 1,942 fabricated on the site and for its covering tube, a FRP tube was adopted. In this article, the construction of the main girder and stay cables, and the construction control during their installation by projection are reported. 7 refs., 14 figs., 9 tabs.

  14. Bilateral implant-retained auricular prosthesis for a patient with congenitally missing ears. A clinical report.

    Kumar, Preeti Satheesh; Satheesh Kumar, K S; Savadi, Ravindra C

    2012-06-01

    Microtia is a major congenital anomaly of the external ear. It includes a spectrum of deformities from a grossly normal but small ear to the absence of the entire external ear. These deformities account for three in every 10,000 births, with bilaterally missing ears seen in fewer than 10% of all cases. Congenital abnormalities of the ear are unlikely to result in the complete absence of the ears, but the patient presented in this article had bilateral congenitally missing ears. There was loss of anatomic landmarks and alteration of normal bony architecture. Minimal tissue was available for retention; therefore, conventional techniques could not be used for achieving retention. A two-implant-supported auricular prosthesis was planned, but the patient was found to have deficient bone in the implant site. Hence the implants were placed posterior to these sites, and the superstructure was modified to accommodate for this change in position of the implant to ensure the esthetic positioning of the prosthesis. © 2012 by the American College of Prosthodontists.

  15. Macro design effects on stress distribution around implants: a photoelastic stress analysis.

    Ozkir, Serhat Emre; Terzioglu, Hakan

    2012-01-01

    Biomechanics is one of the main factors for achieving long-term success of implant supported prostheses. Long-term failures mostly depend on biomechanical complications. It is important to distinguish the effects of macro design of the implants. In this study, the photoelastic response of four different types of implants that were inserted with different angulations were comparatively analyzed. The implant types investigated were screw cylinder (ITI, Straumann AG, Basel, Switzerland), stepped cylinder (Frialit2, Friadent GmbH, Manheim, Germany), root form (Camlog Rootline, Alatatec, Wilshelm, Germany), and cylindrical implant, with micro-threads on the implant neck (Astra, AstraTech, Mölndal, Sweden). In the test models, one of the implants was inserted straight, while the other one was aligned mesially with 15° angles. The superstructures were prepared as single crowns. A 150N loading was applied to the restorations throughout the test. A comparison of the implant designs showed that there were no significant differences between the straight implants; however, between the inclined implants, the most favorable stress distribution was seen with the stepped cylinder implants. The least favorable stress concentration was observed around the root formed implants. Microthreads around the implant neck appeared to be effective in a homogenous stress distribution. Observations showed that misaligned implants caused less stress than straight implants, but the stress concentrations were not homogenous. As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.

  16. Influence of calcinable cylinders cast in cobalt-chromium alloy on the passivity of implant-supported frameworks = Influência de cilindros calcináveis fundidos em cobalto-cromo na passividade de próteses implanto-suportadas

    Triches, Diego Fernandes

    2009-01-01

    Full Text Available Objetivo: Este trabalho avaliou a influência da utilização de cilindros calcináveis no grau de passividade de infra-estruturas que simulam uma prótese parcial fixa de três elementos sobre dois implantes. Metodologia: Foram utilizados dois implantes de hexágono externo de 3,75 mm×10 mm, com seus respectivos pilares intermediários, fixados numa base de aço, formando o modelomestre. A partir disto, foram fabricadas dez infra-estruturas em liga de cobalto-cromo através da técnica de fundição por indução. Foram criados dois grupos: Grupo 1 utilizando cilindros pré-usinados para a fabricação de cinco infra-estruturas; Grupo 2 cinco infra-estruturas fundidas com cilindros de plástico calcináveis. Para avaliação da passividade foram utilizados extensômetros colados na região oclusal e cervical do pôntico das infra-estruturas. A medição foi realizada no momento do aperto do segundo parafuso protético com torque de 10Ncm. Os dados foram analisados pelo teste t de Student (a=0,05. Resultados: As médias (desvio-padrão dos grupos foram de 39,16 (24,74 mV/V no Grupo 1 e 43,76 (21,13 mV/V no Grupo 2. Não houve diferença estatisticamente significante entre os grupos (P=0,815. Conclusão: Considerando-se as limitações deste trabalho, sugere-se que o uso de cilindros calcináveis obtém o mesmo grau de passividade que o uso de cilindros pré-usinados

  17. Case study: highly loaded MSE bridge supporting structure, Syncrude NMAPS conveyor overpasses

    Scherger, B.; Brockbank, B. [Reinforced Earth Company Ltd., Edmonton, AB (Canada); Mimura, W. [Syncrude Canada Ltd., Edmonton, AB (Canada)

    2005-07-01

    A crusher and conveyor system was constructed at the Mildred Lake Oil Sands Mine near Fort McMurray, Alberta in order to facilitate ore delivery from Syncrude's North Mine. As part of this North Mine Auxiliary Production System (NMAPS), Syncrude Canada and their consultant Cosyn Technology identified the need for 3 overpasses over conveyors in the North Mine in order to provide unrestricted crossing over the operating conveyor system for the heavy hauler trucks and light vehicle mine traffic. The overpasses were designed to support the dead load of the granular fill and the live load of two loaded heavy hauler trucks, with a design load for each loaded hauler of 670 900 kg. This paper reviewed various aspects of the design from planning, structure selection, and overall stability and bearing capacity considerations. The different designs in the 3 new overpasses accommodated foundation and loading requirements. The designs ranged from the use of precast one-piece reinforced concrete arches, Mechanically Stabilized Earth (MSE) bridge abutment technology, and a combination of the two. The MSE retaining walls directly supported the bridge superstructure without the use of piles or other deep structural foundations. The design was challenging because of the significant vertical stresses transferred onto the wall. All 3 overpasses also used MSE walls for the supporting end wing walls. The main focus of this paper was on the heavily loaded MSE walls supporting the bridge abutment style overpasses. This structure has illustrated the capability of properly designed MSE wall structures with steel soil reinforcement and reinforced precast concrete face panels to successfully carry bridge footing pressure loadings up to 545 kPa. It was concluded that this case has good potential for use in future bridge projects in both the industrial and highway sectors. 2 refs., 7 figs.

  18. Hybrid FRP-concrete bridge deck system final report I : development and system performance validation.

    2009-10-01

    In this study, the concept of the hybrid FRP-concrete structural systems was applied to both bridge : superstructure and deck systems. Results from the both experimental and computational analysis for : both the hybrid bridge superstructure and deck ...

  19. Complexes superstructurés mixtes Ru/Fe et Ru/Co à ligands polypyridinyles multitopiques : synthèses, caractérisations, propriétés rédox et photorédox.

    Lombard , Jean

    2007-01-01

    This work deals with the synthesis and physico-chemical study of heterobimetallic complexes bearing ruthenium(II)-tris-bipyridine units as photosensitizers covalently linked to a polypyridinic complex unit of iron (II) or cobalt (II), in order to investigate photoinduced electron transfer in such architectures.With bis-bipyridine type ligands, we synthesized a serie of tetranuclear complexes formed by a central complex unit FeII-tris-bipyridine, covalently linked to three RuII-tris-bipyridine...

  20. TECHNO-ECONOMIC ANALYSIS IN A SUPERSTRUCTURE OF A MULTIPLE FLOORS BUILDING (THREE, FIVE, SEVEN AND NINE FLOORS IN REINFORCED CONCRETE AND RIBBED SLABS WITH RECTANGULAR FORM AND DIFFERENT COMPRESSIVE STRENGTH VALUES

    E. F. S. Moraes

    2017-12-01

    Full Text Available Adapting “fck" values between 25 MPa to 40 MPa, in three, five, seven and nine floor buildings for places under winds of up to 30 m/s, this research calculated the cost and inputs of these variations. The results have as a goal to improve multiple floors building design in reinforced concrete and ribbed slabs, and to contribute to economic gains. The results were analysed in five stages. (I Architectural design definition in a 1:1 proportion, (II structural conception, (III structural design, (IV cost composition and (V techno economic parameters. To sum up, the results showed that lower “fck” has presented more viability to few flooring. In addition, with the increase of floors also the “fck” raised, causing higher cost around 16,54% in the beams and 11,16% in the slabs. Moreover, the pillars showed a saving of 28,89% in the cost, ranging by up to 11,93% in the average thickness and 6,29% in the concrete form expenditure per m³. Therefore, the research showed an economic achievement of 5,14% in the overall cost between the number of floor.