WorldWideScience

Sample records for ondes radiofrequences emises

  1. Den onde eller det onde?

    DEFF Research Database (Denmark)

    Nielsen, Kirsten

    2008-01-01

    Artiklen handler om brugen af billeder for den onde (djævelen) og det onde i moderne salmer. Der er en klar tendens til at foretrække et naturbillede som mørket frem for personbilleder. Mørket kan som billede bruges forholdsvis nuanceret og vil i mange tilfælde ikke forudsætte et dybere kendskab ...

  2. Flute Characteristics of and Microwave Emission from a Plasma in a Mirror; Instabilite en Cannelures et Emission de Micro-Ondes par un Plasma dans une Machine a Miroirs; Zhelobkovye kharakteristiki i ehmissiya mikrovoln iz plazmy v zerkale; Caracteristicas del Estriado y Emision de Microondas por un Plasma en un Espejo

    Energy Technology Data Exchange (ETDEWEB)

    Scott, F. R.; Jensen, T. H.; Wharton, C. B. [General Atomic Division, General Dynamics Corporation, San Diego, CA (United States)

    1966-04-15

    construit une machine a miroirs puisee pour etudier la stabilite d'un plasma d'energie relativement faible. Le plasma de 70 eV, forme dans un canon, est canalise ven le miroir par un champ de guidage octopolaire lineaire. La duree du champ du miroir est egale au temps de transit du plasma. Les auteurs ont mesure des densites d'electrons de 10{sup 13} cm{sup -3} dans le plan central du miroir. Ils ont observe deux modes distincts de fonctionnement qui ne dependent que des conditions regnant dans le champ de guidage. Dans le premier mode, le plasma dans le miroir ne semble pas presenter d'instabilite en cannelures, la plus grande partie du plasma d'echappe le long de l'axe', on observe une diffusion radiale anormale lente, il se produit une emission de micro-ondes dont les frequences sont des harmoniques de la frequence cyclotronique des electrons dans l'intervalle entre n = 1 et n = 19 au moins. L'emission de micro-ondes n'est pas compatible avec la branche electronique de l'instabilite de Harris. Les auteurs attribuent la stabilite de ce mode a la fixation des lignes de force par le plasma froid diffusant de la region du champ de guidage. Ils ont observe des densites d'electrons superieurs a 10{sup 11} cm{sup 3} pendant 200 {mu}s dans la region situee entre le miroir et le champ de guidage. La presence d'un cylindre de symetrie axiale dans le champ de guidage a pour effet de diminuer cette densite. Des mesures faites dans cette region fournissent des densites inferieures a 10u cm{sup 3}apres 40 {mu}s. Le plasma qui en resulte, piege dans le miroir, presente des instabilites en cannelures, des pertes de plasma radiales, une emission de micro-ondes irreguliere intense, ainsi qu'une decroissance de densite rapide. Les auteurs ont identifie la cannelure m = 1, dont ils ont suivi la phase dans l'angle 4{pi}. La vitesse de phase possede la meme direction que la derive electronique sous l'influence de B. Le signe de cette vitesse de phase peut s'expliquer par la theorie de Krall

  3. Onde elettromagnetiche

    CERN Document Server

    Toraldo di Francia, Giuliano

    1988-01-01

    Prefazione: "L'opera "Onde Elettromagnetiche" di Giuliano Toraldo di Francia vide la luce per i tipi della Casa Editrice Zanichelli nel lontano 1953. Tradotta ben presto in inglese e in giapponese, ha incontrato il favore di varie generazioni di studenti universitari e un apprezzamento dei docenti che non sembra ancora estinto. Ma è evidente che in trentacinque anni tante cose, troppe cose sono avvenute in quel campo di studio, per poter pensare che oggi il vecchio libro non presenti cospicue lacune. Ed è proprio a colmare tali lacune che ci siamo dedicati nell'elaborare il presente volume, pur conservando quasi tutto il materiale che aveva dato buona prova nel suo progenitore. La mole è inevitabilmente raddoppiata; eppure siamo ben lungi dall'avere esaurito un dominio così vasto, né ci eravamo proposti di farlo. Quello che presentiamo è il frutto di una scelta ragionata. Abbiamo ritenuto opportuno ampliare la parte sulle onde piane (con l'introduzione dei parametri di Stokes, e dei concetti di velocit�...

  4. Tutto (o quasi) sulle onde

    CERN Document Server

    Pierce, John R

    1977-01-01

    Molti dei fenomeni in cui s'imbatte quotidianamente possono essere interpretati in modo semplice alla luce di quello che è uno dei concetti unificanti della fisica, il concetto di onda: dalle onde acustiche che si propagano nell'aria a quelle luminose, dalle onde radio alle onde meccaniche dei cristalli di quarzo impiegati per controllare la frequenza dei radiotrasmettitori, dalle onde sismiche alle onde di probabilità studiate dalla meccanica quantistica, fino alle onde del linguaggio comune, quelle che muovono la superficie dell'acqua.

  5. "Den onde kvinde"

    DEFF Research Database (Denmark)

    Holst, Søren

    2002-01-01

    Et af Dødehavsskrifterne, af den første udgiver kaldet "Den onde kvindes rænker" (4Q184), beskriver en svigefuld kvinde, der lokker fromme mænd i fordærv. Artiklen gennemgår tekstens fortolkningshistorie og påviser den rolle, det har spillet for læsningen, at teksten a priori er blevet opfattet s...

  6. Fri os fra det onde

    DEFF Research Database (Denmark)

    Frandsen, Johs. Nørregaard

    2009-01-01

    Anmeldelse af Ole Bordedals film: Fri os fra det onde. Filmen bruger provinsen som metafor for de menenskelige udkanter og eksistentielle randområder, ligesom han skildrer det ondes princip Udgivelsesdato: maj......Anmeldelse af Ole Bordedals film: Fri os fra det onde. Filmen bruger provinsen som metafor for de menenskelige udkanter og eksistentielle randområder, ligesom han skildrer det ondes princip Udgivelsesdato: maj...

  7. Radiofrequency Neurotomy

    Science.gov (United States)

    ... your specific symptoms. What you can expect Before radiofrequency neurotomy Let your doctor know if you take ... tobacco products the day of your procedure. During radiofrequency neurotomy Radiofrequency neurotomy is an outpatient procedure, so ...

  8. Para onde vai a Geografia?

    Directory of Open Access Journals (Sweden)

    Angélica Karina Dillenburg Horii

    2015-12-01

    Full Text Available O presente artigo aborda a evolução da Geografia enquanto pensamento científico, analisando seu objeto de estudo e suas categorias de análise durante todo o percurso da criação desse saber. Observa primeiramente a formação da Geografia Clássica, que teve seus princípios já instituídos na Antiguidade com Ptolomeu e Estrabão, desdobrando-se no período Iluminista com Ritter e Humboldt que fornecerão uma nova temporalidade a essa ciência. Atinge seu ápice na Modernidade Industrial com a racionalidade de Kant, onde Ratzel e La Blache utilizarão o determinismo e o possibilismo para constituir um discurso científico para a Geografia. Finaliza apontando a nova compreensão do mundo, conhecida como pós-modernismo por David Harvey (1992 ou por Milton Santos (1996 como Globalização, que junto a outros geógrafos e pesquisadores, indicam caminhos de análise dessa ciência na compreensão do seu objeto de estudo. Um diálogo entre os autores na construção do pensamento geográfico.

  9. Radiofrequency radiation

    International Nuclear Information System (INIS)

    Elder, J.A.; Czerski, P.A.; Stuchly, M.A.; Mild, K.H.; Sheppard, A.R.

    1989-01-01

    High-level radiofrequency radiation is a source of thermal energy that carries all of the known implications of heating for biological systems, including burns, temporary and permanent changes in reproduction, cataracts, and death. In general, no changes in chromosomes, DNA or the reproductive potential of animals exposed to RF radiation have been reported in the absence of significant rises in temperature, though there are limited data on DNA and chromosomal changes at non-thermal levels. Human data are currently limited and do not provide adequate information about the relationship between prolonged low-level RF radiation exposure and increased mortality or morbidity, including cancer incidence. In epidemiological studies and clinical reports of RF effects in man, the problems of quantification are numerous and include uncertainties about ''dose'', health effects, latent periods, dose-response relationships, and interactions with other physical or chemical agents. 228 refs, 6 figs, 2 tabs

  10. WORKSHOPS: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991

  11. WORKSHOPS: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-01-15

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991.

  12. Radiofrequency Ablation of Lung Tumors

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Radiofrequency Ablation (RFA) / Microwave Ablation (MWA) of Lung Tumors ... and Microwave Ablation of Lung Tumors? What are Radiofrequency and Microwave Ablation of Lung Tumors? Radiofrequency ablation, ...

  13. Radiofrequency ablation in dermatology

    Directory of Open Access Journals (Sweden)

    Sachdeva Silonie

    2007-01-01

    Full Text Available Radiofreqeuency ablation is a versatile dermatosurgical procedure used for surgical management of skin lesions by using various forms of alternating current at an ultra high frequency. The major modalities in radiofrequency are electrosection, electrocoagulation, electrodessication and fulguration. The use of radiofrequency ablation in dermatosurgical practice has gained importance in recent years as it can be used to treat most of the skin lesions with ease in less time with clean surgical field due to adequate hemostasis and with minimal side effects and complications. This article focuses on the major tissue effects and factors influencing radiofrequency ablation and its application for various dermatological conditions.

  14. RADIOFREQUENCY SUPERCONDUCTIVITY: Workshop

    International Nuclear Information System (INIS)

    Lengeler, Herbert

    1989-01-01

    Superconducting radiofrequency is already playing an important role in the beam acceleration system for the TRISTAN electron-positron collider at the Japanese KEK Laboratory and new such systems are being prepared for other major machines. Thus the fourth Workshop on Radiofrequency Superconductivity, organized by KEK under the chairmanship of local specialist Yuzo Kojima and held just before the International Conference on High Energy Accelerators, had much progress to review and even more to look forward to

  15. Radiofrequency ablation of osteoid osteoma

    NARCIS (Netherlands)

    Vanderschueren, Geert Maria Joris Michael

    2009-01-01

    The main purpose of this thesis was to evaluate the effectiveness and safety of CT-guided radiofrequency ablation for the treatment of spinal and non-spinal osteoid osteomas. Furthermore, the technical requirements needed for safe radiofrequency ablation and the clinical outcome after radiofrequency

  16. Adolescentes e grávidas: onde buscam apoio?

    Directory of Open Access Journals (Sweden)

    Roselí Aparecida Godinho

    Full Text Available Adolescência é época de crise, mudança, readaptação ao novo corpo e de novas atitudes frente a vida. Se somarmos a isso o significado da gravidez, dos pontos de vista pessoal, social e familiar, compreenderemos como a gestação pode ser um evento difícil para a adolescente. O presente estudo teve como objetivo identificar onde as adolescentes grávidas buscam apoio. Evidenciou-se que as entrevistadas puderam contar com o apoio da família, principalmente dos pais e, com menos freqüência com o do pai do bebê, bem como a aceitação da gravidez, sua relação com o abandono escolar, a visão idealizada dessas garotas acerca da gestação e expectativas futuras, a preocupação com aspectos biológicos e a despreocupação com problemas concretos.

  17. Fast beam radiofrequency spectroscopy

    International Nuclear Information System (INIS)

    Pipkin, F.M.

    1983-01-01

    The combination of a fast atom or ion beam derived from a small accelerator with radiofrequency spectroscopy methods provides a powerful method for measuring the fine structure of atomic and molecular systems. The fast beam makes possible measurements in which two separated oscillatory fields are used to obtain resonance lines whose widths are less than the natural line width due to the lifetimes of the states. The separated oscillatory field lines have, in addition, a number of features which make possible measurements with greater precision and less sensitivity to systematic errors. The fast beam also makes accessible multiple photon radiofrequency transitions whose line width is intrinsically narrower than that of the single photon transitions and which offer great potential for high precision measurements. This report focuses on the techniques and their promise. Recent measurements of the fine structure of H and He + are used as illustrations

  18. WORKSHOP: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-10-15

    The Second Workshop on Radiofrequency Superconductivity was held at CERN from 23-27 July, four years after the first, organized at Karlsruhe. 35 invited talks were presented to the about 80 participants from Australia, Brazil, Europe, Japan and the United States. For the first time, ten Laboratories operating or planning superconducting accelerators for heavy ions participated and shared their experience with the community proposing the use of superconducting accelerating sections for electron accelerators.

  19. WORKSHOP: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    The Second Workshop on Radiofrequency Superconductivity was held at CERN from 23-27 July, four years after the first, organized at Karlsruhe. 35 invited talks were presented to the about 80 participants from Australia, Brazil, Europe, Japan and the United States. For the first time, ten Laboratories operating or planning superconducting accelerators for heavy ions participated and shared their experience with the community proposing the use of superconducting accelerating sections for electron accelerators

  20. Radiofrequency in cosmetic dermatology.

    Science.gov (United States)

    Beasley, Karen L; Weiss, Robert A

    2014-01-01

    The demand for noninvasive methods of facial and body rejuvenation has experienced exponential growth over the last decade. There is a particular interest in safe and effective ways to decrease skin laxity and smooth irregular body contours and texture without downtime. These noninvasive treatments are being sought after because less time for recovery means less time lost from work and social endeavors. Radiofrequency (RF) treatments are traditionally titrated to be nonablative and are optimal for those wishing to avoid recovery time. Not only is there minimal recovery but also a high level of safety with aesthetic RF treatments. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. International radiofrequency standards

    International Nuclear Information System (INIS)

    Lincoln, J.

    2001-01-01

    Of the various radiofrequency standards in use around the world, many are based on or similar to the Guidelines published by ICNIRP (The International Commission on Non-ionising Radiation Protection). This organisation is a working group operating in co-operation with the Environmental Health division of the World Health Organisation (WHO). This paper presents a very brief overview of current international standards, beginning with a summary of the salient points of the ICNIRP Guidelines. It should be remembered that these are guidelines only and do not exist as a separate standard. Copyright (2001) Australasian Radiation Protection Society Inc

  2. Spatial analysis of noise emission at the Los Azufres geothermal field, Mich.; Analisis espacial de emision de ruido en el campo geotermico de Los Azufres, Mich.

    Energy Technology Data Exchange (ETDEWEB)

    Camarena Magana, Emilio; Ordaz Mendez, Christian A. [Comision Federal de Electricidad, Residencia de Los Azufres, Morelia, Michoacan (Mexico)]. E-mail: emilio.camarena@cfe.gob.mx

    2010-01-15

    To verify noise emissions from the usual activities in an operating geothermal field, noise measurements were carried out in a 4.2 km{sup 2} area in the southern zone of the Los Azufres, Mich., geothermal field. There are seven production wells operating here and three abandoned wells. The average noise emission in the southern zone was 36.5 decibels (dB), regarded as the natural reading of environmental-noise emission. In the Christmas (valves) tree for operating production wells, the noise ranges from 70.9 to 91.7 dB, while in open discharging valves for steam-pipes, the noise can reach 118 dB. In Mexico the maximum permissible limit of noise on the periphery of a property is 68 dB in daytime and 65 dB at night. Based on measurements made at the periphery of lots where the geothermal wells are located, four out of seven production wells measured do not exceed the maximum allowable level, while the other three seem to exceed it. However no definite limits exist for the lots. It is recommended that the measurement points as indicated by the official standard in environmental matters be re-established, which will enable noise emissions by several wells that have exceeded the permissible limit, to actually fall within it. [Spanish] Se realizaron mediciones sonicas en un area de 4.2 km{sup 2} localizada en la zona sur del campo geotermico de Los Azufres, Mich., a fin de verificar la emision de ruido asociada a las actividades usuales en un campo geotermico en operacion. En esta area se encuentran siete pozos productores en operacion y tres pozos abandonados. La emision promedio de ruido en estos ultimos fue de 36.5 decibeles (dB), considerandose como la condicion natural de emision de ruido ambiental. En el arbol de valvulas de los pozos productores en operacion el ruido va de los 70.9 a los 91.7 dB, mientras que en valvulas abiertas de descarga de vaporductos la emision puede llegar hasta los 118 dB. En Mexico el limite maximo permisible de ruido en la periferia de

  3. Radiofrequency attenuator and method

    Science.gov (United States)

    Warner, Benjamin P [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM; Burrell, Anthony K [Los Alamos, NM; Agrawal, Anoop [Tucson, AZ; Hall, Simon B [Palmerston North, NZ

    2009-01-20

    Radiofrequency attenuator and method. The attenuator includes a pair of transparent windows. A chamber between the windows is filled with molten salt. Preferred molten salts include quarternary ammonium cations and fluorine-containing anions such as tetrafluoroborate (BF.sub.4.sup.-), hexafluorophosphate (PF.sub.6.sup.-), hexafluoroarsenate (AsF.sub.6.sup.-), trifluoromethylsulfonate (CF.sub.3SO.sub.3.sup.-), bis(trifluoromethylsulfonyl)imide ((CF.sub.3SO.sub.2).sub.2N.sup.-), bis(perfluoroethylsulfonyl)imide ((CF.sub.3CF.sub.2SO.sub.2).sub.2N.sup.-) and tris(trifluoromethylsulfonyl)methide ((CF.sub.3SO.sub.2).sub.3C.sup.-). Radicals or radical cations may be added to or electrochemically generated in the molten salt to enhance the RF attenuation.

  4. Electromagnetic field sources in radiofrequency

    International Nuclear Information System (INIS)

    Oliveira, C.; Sebastiao, D.; Ladeira, D.; Antunes, M.; Correia, L.M.

    2010-01-01

    In the scope of the monIT Project, several measurements were made of electromagnetic fields in Portugal. This paper presents an analysis of the sources operating in the radiofrequency range, resulting from 2429 measurements in 466 locations.

  5. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  6. Measurement of radiofrequency fields

    International Nuclear Information System (INIS)

    Leonowich, J.A.

    1992-05-01

    We are literally surrounded by radiofrequency (RFR) and microwave radiation, from both natural and man-made sources. The identification and control of man-made sources of RFR has become a high priority of radiation safety professionals in recent years. For the purposes of this paper, we will consider RFR to cover the frequencies from 3 kHz to 300 MHz, and microwaves from 300 MHz to 300 GHz, and will use the term RFR interchangeably to describe both. Electromagnetic radiation and field below 3 kHz is considered Extremely Low Frequency (ELF) and will not be discussed in this paper. Unlike x- and gamma radiation, RFR is non-ionizing. The energy of any RFR photon is insufficient to produce ionizations in matter. The measurement and control of RFR hazards is therefore fundamentally different from ionizing radiation. The purpose of this paper is to acquaint the reader with the fundamental issues involved in measuring and safely using RFR fields. 23 refs

  7. New-generation radiofrequency technology.

    Science.gov (United States)

    Krueger, Nils; Sadick, Neil S

    2013-01-01

    Radiofrequency (RF) technology has become a standard treatment in aesthetic medicine with many indications due to its versatility, efficacy, and safety. It is used worldwide for cellulite reduction; acne scar revision; and treatment of hypertrophic scars and keloids, rosacea, and inflammatory acne in all skin types. However, the most common indication for RF technology is the nonablative tightening of tissue to improve skin laxity and reduce wrinkles. Radiofrequency devices are classified as unipolar, bipolar, or multipolar depending on the number of electrodes used. Additional modalities include fractional RF; sublative RF; phase-controlled RF; and combination RF therapies that apply light, massage, or pulsed electromagnetic fields (PEMFs). This article reviews studies and case series on these devices. Radiofrequency technology for aesthetic medicine has seen rapid advancements since it was used for skin tightening in 2003. Future developments will continue to keep RF technology at the forefront of the dermatologist's armamentarium for skin tightening and rejuvenation.

  8. Non-surgical radiofrequency facelift.

    Science.gov (United States)

    Narins, David J; Narins, Rhoda S

    2003-10-01

    There has been considerable interest in using non-ablative methods to rejuvenate the skin. The ThermaCool TC (Thermage Inc.) is a radiofrequency (RF) device that has been introduced to induce tightening of the address the problem of skin via a uniform volumetric heating into the deep dermis tightening, resulting in a 'non-surgical facelift'. Radiofrequency produces a uniform volumetric heating into the deep dermis. Twenty treatment areas in 17 patients were treated to evaluate the efficacy and safety of RF treatment to the brow and jowls. The technique was found to produce gradual tightening in most patients, and there were no adverse effects.

  9. Radiofrequency fields in our surroundings

    International Nuclear Information System (INIS)

    2011-01-01

    In 2010, the National Radiation Protection Authority (NRPA) with the Post and Telecommunications Authority carried out a project where it is measured radiofrequency fields from various telecom systems in homes, kindergartens, schools, offices, and urban environments. Close to 99 percent of the measurement points were found values of less than one thousandth of the maximum. No values were near the limits. (AG)

  10. WORKSHOP: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Tückmantel, Joachim

    1993-01-01

    Full text: With superconducting radiofrequency playing a major role in the push for new machines to break fresh physics frontiers, it has become a tradition for experts and newcomers in this field from all over the world to meet every second year to hear progress reports from laboratories and to discuss common problems and possible solutions. The sixth such workshop was held from 4-8 October under the chairmanship of Ron Sundelin at the Continuous Electron Beam Accelerator Facility (CEBAF) under construction in Newport News, Virginia. With 170 participants from 14 countries including Eastern Europe and China, it reflected the growing interest in the field - looking back to 1984, when CERN was the host laboratory, the second workshop had less than 100 participants. The CEBAF meeting began with laboratory status reports, covering both high beam energy ('high beta') applications with 'spherical' cavities (as with CERN's LEP200), all using niobium as superconductor and working between 352 MHz and 3 GHz, and lower energy (low beta') applications with geometrically more complicated shapes such as quarter or half wave, split ring or spoke resonators, some using electrodeposited lead as superconductor and working around 100 MHz. During these talks it became clear that more and more laboratories have focused on routine problems, such as reliable series production and testing, running cavities with ancillaries in the machines, or building complete prototypes for projects to be approved by critical funding authorities. This contrasts with the heady days just a few years ago when - at least in the high beta community - the main objective was to explore new ideas. State-of-the-art summaries showed how at 1.3 and 3 GHz 25-30 MV/m have been reached by several laboratories using different preparation methods. Newer developments for common problems included r.f. windows, couplers, controls, and especially field emission, public enemy number one for

  11. Radiofrequency Ablation of Hepatic Cysts : Case Report

    International Nuclear Information System (INIS)

    Lee, Ye Ri; Kim, Pyo Nyun

    2005-01-01

    Radiofrequency ablation has been frequently performed on intra-hepatic solid tumor, namely, hepatocellular carcinoma, metastatic tumor and cholangio carcinoma, for take the cure. But, the reports of radiofrequency ablation for intrahepatic simple cysts are few. In vitro experiment of animal and in vivo treatment for intrahepatic cysts of human had been reported in rare cases. We report 4 cases of radiofrequency ablation for symptomatic intrahepatic cysts

  12. Superconducting Radio-Frequency Cavities

    Science.gov (United States)

    Padamsee, Hasan S.

    2014-10-01

    Superconducting cavities have been operating routinely in a variety of accelerators with a range of demanding applications. With the success of completed projects, niobium cavities have become an enabling technology, offering upgrade paths for existing facilities and pushing frontier accelerators for nuclear physics, high-energy physics, materials science, and the life sciences. With continued progress in basic understanding of radio-frequency superconductivity, the performance of cavities has steadily improved to approach theoretical capabilities.

  13. Techniques d'inspection par ondes guidees ultrasonores d'assemblages brases dans des reacteurs aeronautiques =

    Science.gov (United States)

    Comot, Pierre

    L'industrie aeronautique, cherche a etudier la possibilite d'utiliser de maniere structurelle des joints brases, dans une optique de reduction de poids et de cout. Le developpement d'une methode d'evaluation rapide, fiable et peu couteuse pour evaluer l'integrite structurelle des joints apparait donc indispensable. La resistance mecanique d'un joint brase dependant principalement de la quantite de phase fragile dans sa microstructure. Les ondes guidees ultrasonores permettent de detecter ce type de phase lorsqu'elles sont couplees a une mesure spatio-temporelle. De plus la nature de ce type d'ondes permet l'inspection de joints ayant des formes complexes. Ce memoire se concentre donc sur le developpement d'une technique basee sur l'utilisation d'ondes guidees ultrasonores pour l'inspection de joints brases a recouvrement d'Inconel 625 avec comme metal d'apport du BNi-2. Dans un premiers temps un modele elements finis du joint a ete utilise pour simuler la propagation des ultrasons et optimiser les parametres d'inspection, la simulation a permis egalement de demontrer la faisabilite de la technique pour la detection de la quantite de phase fragile dans ce type de joints. Les parametres optimises sont la forme de signal d'excitation, sa frequence centrale et la direction d'excitation. Les simulations ont montre que l'energie de l'onde ultrasonore transmise a travers le joint aussi bien que celle reflechie, toutes deux extraites des courbes de dispersion, etaient proportionnelles a la quantite de phase fragile presente dans le joint et donc cette methode permet d'identifier la presence ou non d'une phase fragile dans ce type de joint. Ensuite des experimentations ont ete menees sur trois echantillons typiques presentant differentes quantites de phase fragile dans le joint, pour obtenir ce type d'echantillons differents temps de brasage ont ete utilises (1, 60 et 180 min). Pour cela un banc d'essai automatise a ete developpe permettant d'effectuer une analyse similaire

  14. Hyperkalaemia after radiofrequency ablation of hepatocellular carcinoma

    NARCIS (Netherlands)

    Verhoevena, BH; Haagsma, EB; Appeltans, BMG; Slooff, MJH; de Jong, KP

    Radiofrequency ablation of liver tumours is a useful therapy for otherwise unresectable tumours. The complication rate is said to be low. In this case report we describe hyperkalaemia after radiofrequency ablation of a hepatocellular carcinoma in a patient with end-stage renal insufficiency. (C)

  15. Predicting nurses' acceptance of radiofrequency identification technology.

    Science.gov (United States)

    Norten, Adam

    2012-10-01

    The technology of radiofrequency identification allows for the scanning of radiofrequency identification-tagged objects and individuals without line-of-sight requirements. Healthcare organizations use radiofrequency identification to ensure the health and safety of patients and medical personnel and to uncover inefficiencies. Although the successful implementation of a system incorporating radiofrequency identification technologies requires acceptance and use of the technology, some nurses using radiofrequency identification in hospitals feel like "Big Brother" is watching them. This predictive study used a theoretical model assessing the effect of five independent variables: privacy concerns, attitudes, subjective norms, controllability, and self-efficacy, on a dependent variable, nurses' behavioral intention to use radiofrequency identification. A Web-based questionnaire containing previously validated questions was answered by 106 US RNs. Multiple linear regression showed that all constructs together accounted for 60% of the variance in nurses' intention to use radiofrequency identification. Of the predictors in the model, attitudes provided the largest unique contribution when the other predictors in the model were held constant; subjective norms also provided a unique contribution. Privacy concerns, controllability, and self-efficacy did not provide a significant contribution to nurses' behavioral intention to use radiofrequency identification.

  16. A la poursuite des ondes gravitationnelles dernières nouvelles de l'Univers

    CERN Document Server

    Binétruy, Pierre

    2016-01-01

    Nous sommes habitués à observer la lumière des étoiles pour comprendre l’Univers. Ce n’est pourtant pas la radiation la plus présente dans l’Univers mais c’est celle que nous avons d’abord identifiée car nos yeux sont des « détecteurs de lumière ». Or l’Univers est mu par la gravité, non par la lumière. C’est donc la radiation associée, appelée onde gravitationnelle, qui est de première importance pour comprendre le fonctionnement de l’Univers. La détection des ondes gravitationnelles annoncée le 11 février 2016, par le détecteur américain Ligo, a fait l'effet d'une bombe dans les médias. Ce livre, rédigé par un acteur important de cette physique de pointe, nous décrit cet étrange univers gravitationnel qui s'ouvre à nous.

  17. 47 CFR 2.801 - Radiofrequency device defined.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...

  18. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  19. Le séchage combiné convection-micro-ondes : modelisation-validation-optimisation

    OpenAIRE

    Constant , Thiéry

    1992-01-01

    Not available; Ce travail est consacré à l'étude du séchage combiné convection-micro-ondes, le matériau choisi pour l'étude étant un béton cellulaire. Il comporte une partie théorique et une partie expérimentale. D’un point de vue théorique, deux points sont plus particulièrement discutés: la formulation du terme source volumique d'énergie et la modélisation des transferts de chaleur et de masse avec prise en compte du gradient de pression totale de la phase gazeuse. D’un point de vue expérim...

  20. [Radiofrequency ablation of hepatocellular carcinoma].

    Science.gov (United States)

    Widmann, Gerlig; Schullian, Peter; Bale, Reto

    2013-03-01

    Percutaneous radiofrequency ablation (RFA) is well established in the treatment of hepatocellular carcinoma (HCC). Due to its curative potential, it is the method of choice for non resectable BCLC (Barcelona Liver Clinic) 0 and A. RFA challenges surgical resection for small HCC and is the method of choice in bridging for transplantation and recurrence after resection or transplantation. The technical feasibility of RFA depends on the size and location of the HCC and the availability of ablation techniques (one needle techniques, multi-needle techniques). More recently, stereotactic multi-needle techniques with 3D trajectory planning and guided needle placement substantially improve the spectrum of treatable lesions including large volume tumors. Treatment success depends on the realization of ablations with large intentional margins of tumor free tissue (A0 ablation in analogy to R0 resection), which has to be documented by fusion of post- with pre-ablation images, and confirmed during follow-up imaging.

  1. Photo and cathode luminescence emission in oxide silicium films implanted with silicium; Emision de foto y catodoluminiscencia en peliculas de oxido de silicio termico implantadas con silicio

    Energy Technology Data Exchange (ETDEWEB)

    Flores, F; Aceves, M. [Instituto Nacional de Astrofisica Optica y Electronica, Mexico, D.F. (Mexico); Carrillo, J. [Benemrita Universidad Autonoma de Puebla, Puebla (Mexico); Dominguez, C. [Universida Autonoma de Barcelona, Barcelona (Spain); Falcony, C. [Instituto Politecnico Nacional, Mexico, D.F. (Mexico)

    2001-10-01

    We studied the photo and cathodoluminescence of Silicon Rich Oxides (SRO) obtained by ion implant of Si in thermal oxides. Doses of 10{sup 1}6 cm{sup -}2 (low dose) and 10{sup 1}7 cm{sup -}2 (high dose) and implant energy of 150 keV were used. The films were annealed for 30, 60 and 180 minutes in nitrogen at 1100 Celsius degrees. The spectra show photo and cathodoluminescence emission in the visible range, the bands in the spectra change with the conditions of ion implant and annealing. The films without thermal treatment in both dose present photoluminescence bands around 1.9 eV (band B) and 2.4 eV (band C). With the thermal treatments, the band B disappears. In the case of the films with low dose, the band C shows a blue shift and a decrease in intensity. The high dose films have a band centered in 1.7 eV (band A) that increases its intensity with annealings. The cathodoluminescence bands in all the cases are in 2.7 eV (band D) and they present changes with the thermal treatments that it seems they depend on the variation in the implant parameters. [Spanish] Se estudian las propiedades de foto y la catodoluminiscencia de peliculas de oxidos de silicio ricos en Si (Silicon Rich Oxide SRO) obtenidas por implantacion ionica de Si en oxidos termicos. Se usaron dosis de 10{sup 1}6 cm{sup -}2 (dosis baja) y 10{sup 1}7 cm{sup -}2 (dosis alta) y energia de implantacion de 150 keV. Las peliculas se sometieron a tratamientos termicos por 30, 60 y 180 minutos en nitrogeno de 1100 grados centigrados. Se encontro emision foto y catodoluminiscente en el rango visible, las bandas en los espectros cambian con las condiciones de implantacion ionica y con los tratamientos termicos. Las peliculas sin tratamiento termico en ambas dosis presentan bandas de fotoluminiscencia alrededor de 1.9 eV (banda B) y 2.4 eV (banda C). Con los tratamientos termicos, la banda B desaparece. En el caso de las peliculas con dosis baja, la banda C muestra un corrimiento hacia el azul junto con una

  2. New resonant circuits for the ISOLTRAP radiofrequency quadrupole trap

    CERN Document Server

    SENECAL, Pierre

    2015-01-01

    This report describes my work during my Summer Student Program. My main project was building and testing a resonance-circuit box for a radio-frequency power supply used with the radio-frequency cooler and buncher.

  3. Radiofrequency ablation of pulmonary tumors

    Energy Technology Data Exchange (ETDEWEB)

    Crocetti, Laura, E-mail: l.crocetti@med.unipi.i [Division of Diagnostic Imaging and Intervention, Department of Liver Transplants, Hepatology and Infectious Diseases, Pisa University School of Medicine (Italy); Lencioni, Riccardo [Division of Diagnostic Imaging and Intervention, Department of Liver Transplants, Hepatology and Infectious Diseases, Pisa University School of Medicine (Italy)

    2010-07-15

    The development of image-guided percutaneous techniques for local tumor ablation has been one of the major advances in the treatment of solid tumors. Among these methods, radiofrequency (RF) ablation is currently established as the primary ablative modality at most institutions. RF ablation is accepted as the best therapeutic choice for patients with early-stage hepatocellular carcinoma when liver transplantation or surgical resection are not suitable options and is considered as a viable alternate to surgery for inoperable patients with limited hepatic metastatic disease, especially from colorectal cancer. Recently, RF ablation has been demonstrated to be a safe and valuable treatment option for patients with unresectable or medically inoperable lung malignancies. Resection should remain the standard therapy for non-small cell lung cancer (NSCLC) but RF ablation may be better than conventional external-beam radiation for the treatment of the high-risk individual with NSCLC. Initial favourable outcomes encourage combining radiotherapy and RF ablation, especially for treating larger tumors. In the setting of colorectal cancer lung metastases, survival rates provided by RF ablation in selected patients, are substantially higher than those obtained with any chemotherapy regimens and provide indirect evidence that RF ablation therapy improves survival in patients with limited lung metastatic disease.

  4. Dielectric-filled radiofrequency linacs

    Energy Technology Data Exchange (ETDEWEB)

    Faehl, R J; Keinigs, R K; Pogue, E W [Los Alamos National Lab., NM (United States)

    1997-12-31

    High current, high brightness electron beam accelerators promise to open up dramatic new applications. Linear induction accelerators are currently viewed as the appropriate technology for these applications. A concept by Humphries and Hwang may permit radiofrequency accelerators to fulfill the same functions with greater simplicity and enhanced flexibility. This concept involves the replacement of vacuum rf cavities with dielectric filled ones. Simple analysis indicates that the resonant frequencies are reduced by a factor of ({epsilon}{sub 0}/{epsilon}){sup 1/2} while the stored energy is increased by {epsilon}/{epsilon}{sub 0}. For a high dielectric constant like water, this factor can approach 80. A series of numerical calculations of simple pill-box cavities was performed. Eigenfunctions and resonant frequencies for a full system configuration, including dielectric material, vacuum beamline, and a ceramic window separating the two have been computed. These calculations are compared with the results of a small experimental cavity which have been constructed and operated. Low power tests show excellent agreement. (author). 4 figs., 8 refs.

  5. The radiofrequency magnetic dipole discharge

    Energy Technology Data Exchange (ETDEWEB)

    Martines, E., E-mail: emilio.martines@igi.cnr.it; Zuin, M.; Cavazzana, R.; Fassina, A.; Spolaore, M. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Marcante, M. [Dipartimento di Fisica, Università di Trento, via Sommarive 14, 38123 Povo, TN (Italy); TIFPA, Trento Institute for Fundamental Physics and Applications INFN, 38123 Trento (Italy)

    2016-05-15

    This paper describes a novel and simple concept of plasma source, which is able to produce a radiofrequency magnetized discharge with minimal power requirements. The source is based on the magnetron concept and uses a permanent magnet as an active electrode. The dipolar field produced by the magnet confines the electrons, which cause further ionization, thus producing a toroidally shaped plasma in the equatorial region around the electrode. A plasma can be ignited with such scheme with power levels as low as 5 W. Paschen curves have been built for four different working gases, showing that in Helium or Neon, plasma breakdown is easily obtained also at atmospheric pressure. The plasma properties have been measured using a balanced Langmuir probe, showing that the electron temperature is around 3–4 eV and higher in the cathode proximity. Plasma densities of the order of 10{sup 16 }m{sup −3} have been obtained, with a good positive scaling with applied power. Overall, the electron pressure appears to be strongly correlated with the magnetic field magnitude in the measurement point.

  6. The radiofrequency magnetic dipole discharge

    Science.gov (United States)

    Martines, E.; Zuin, M.; Marcante, M.; Cavazzana, R.; Fassina, A.; Spolaore, M.

    2016-05-01

    This paper describes a novel and simple concept of plasma source, which is able to produce a radiofrequency magnetized discharge with minimal power requirements. The source is based on the magnetron concept and uses a permanent magnet as an active electrode. The dipolar field produced by the magnet confines the electrons, which cause further ionization, thus producing a toroidally shaped plasma in the equatorial region around the electrode. A plasma can be ignited with such scheme with power levels as low as 5 W. Paschen curves have been built for four different working gases, showing that in Helium or Neon, plasma breakdown is easily obtained also at atmospheric pressure. The plasma properties have been measured using a balanced Langmuir probe, showing that the electron temperature is around 3-4 eV and higher in the cathode proximity. Plasma densities of the order of 1016 m-3 have been obtained, with a good positive scaling with applied power. Overall, the electron pressure appears to be strongly correlated with the magnetic field magnitude in the measurement point.

  7. Measurement of wave number spectrums; Mesure des spectres de nombres d'onde

    Energy Technology Data Exchange (ETDEWEB)

    Perceval, F. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-03-01

    To measure wave lengths in an ionized medium, the cross-correlation product of the signal collected by a fixed probe and that collected by a movable one exploring the medium, is carried out by an interferometer. In order to determine the various modes, we have made a device which computes the Fourier transform of the signal. The influence of the phase at the origin, of the damping of the signal and of the finite explored length has been studied in order to make a numerical calculation of the Fourier transform. (author) [French] Pour mesurer des longueurs d'onde dans un milieu ionise, nous effectuons a l'aide d'un interferometre un produit d'intercorrelation entre le signal collecte par une sonde fixe et celui d'une sonde mobile explorant le milieu. Afin de pouvoir determiner les differents modes constituant ces signaux, nous avons realise un dispositif qui effectue l'analyse de Fourier de tels enregistrements. L'influence de la phase a l'origine, de l'amortissement du signal et de la longueur finie d'exploration, a ete etudiee en vue du calcul numerique de la transformee de Fourier. (auteur)

  8. Ablation of liver metastases by radiofrequency

    International Nuclear Information System (INIS)

    Baere, T. de

    2012-01-01

    Radiofrequency is a thermal ablative technique that is most often used percuteanously under image guidance. Thermal damage is obtained through frictional heating of a high frequency current. The maximal volume of destruction obtained in one radiofrequency delivery is around 4 cm and consequently, best indication for treatment are tumours below 3 cm. When compared, radiofrequency and surgical removal for tumours below 25 mm in diameter demonstrated a rate of incomplete resection/ablation of 6% and 7.3% respectively. Median survival after the first radiofrequency of a liver metastasis of CRC is reported to be 24 to 52 months with a 5 years overall survival of 18 to 44%. The median overall survival increases from 22 to 48 months depending on the use of radiofrequency ablation as rescue treatment after failure of others, or as a first line treatment. For patients with a single tumour, less than 4 cm, the survival rates at 1, 3, and 5 years are respectively 97%, 84% and 40%, with a median survival of 50 months. Follow-up imaging requires to use contrast-enhanced CT or MRI, looking for local recurrences evidenced by local foci of enhancement at the periphery of the ablation zone. (author)

  9. A survey on monopolar radiofrequency treatment.

    Science.gov (United States)

    Suh, Dong Hye; Hong, Eun Sun; Kim, Hyun Joo; Lee, Sang Jun; Kim, Hei Sung

    2017-09-01

    This questionnaire-based study was aimed to measure the level of appreciation, awareness of the special tips, and practice patterns of monopolar radiofrequency among Korean dermatologists practicing a specific monopolar radiofrequency device (Thermage® Inc., Hayward, CA). A total of 82 surveys were analyzed to show that the majority of participants (78.8%) were highly satisfied with the outcomes of monopolar radiofrequency treatment. All respondents were aware of the Eye Tip 0.25 cm 2 , and the majority knew the difference between the Face tip (blue) and the Total tip (orange). Most (86.3%) agreed to the statement that 900 shots were appropriate for facial tightening in those between the ages of 35 and 65 years. 66.2% of participants reported to have perform monopolar radiofrequency to extra-facial sites within the past year. As for the tips, the Total tip was most popular for all body sties and the Big tip was favored for the abdomen, thighs and buttock. We hope our data allow dermatologists to better utilize monopolar radiofrequency. © 2017 Wiley Periodicals, Inc.

  10. 47 CFR 1.1310 - Radiofrequency radiation exposure limits.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency radiation exposure limits. 1... Procedures Implementing the National Environmental Policy Act of 1969 § 1.1310 Radiofrequency radiation... exposure to radiofrequency (RF) radiation as specified in § 1.1307(b), except in the case of portable...

  11. 21 CFR 882.4400 - Radiofrequency lesion generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion generator. 882.4400 Section... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4400 Radiofrequency lesion generator. (a) Identification. A radiofrequency lesion generator is a device used to produce...

  12. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  13. Radiofrequency-thermoablation in malignant liver disease

    International Nuclear Information System (INIS)

    Pichler, L.; Anzboeck, W.; Paertan, G.; Hruby, W.

    2002-01-01

    The clinical application of radiofrequency tumor ablation in primary liver tumors and metastatic liver disease is rapidly growing because this technique has proven to be simple, safe, and effective in first clinical studies. Most of the patients with malignant liver disease are not candidates for surgical resection due localisation or comorbidity, so radiofrequency therapy offers a good alternative for inoperable patients. With this method, high frequency alternating current is delivered to tissue via a needle electrode, the produced heat leads to coagulation necrosis. The largest focus of necrosis that can be induced with the currently available systems is approximately 4-5 cm with a single application. The radiofrequency needle is usually placed with US or CT guidance. For follow up examinations CT and MRI can be used, they proved to be equally accurate in the assessment of treatment response. (orig.) [de

  14. Radio-frequency integrated-circuit engineering

    CERN Document Server

    Nguyen, Cam

    2015-01-01

    Radio-Frequency Integrated-Circuit Engineering addresses the theory, analysis and design of passive and active RFIC's using Si-based CMOS and Bi-CMOS technologies, and other non-silicon based technologies. The materials covered are self-contained and presented in such detail that allows readers with only undergraduate electrical engineering knowledge in EM, RF, and circuits to understand and design RFICs. Organized into sixteen chapters, blending analog and microwave engineering, Radio-Frequency Integrated-Circuit Engineering emphasizes the microwave engineering approach for RFICs. Provide

  15. The radiofrequency frontier: a review of radiofrequency and combined radiofrequency pulsed-light technology in aesthetic medicine.

    Science.gov (United States)

    Sadick, Neil; Sorhaindo, Lian

    2005-05-01

    Radiofrequency (RF) and combined RF light source technologies have established themselves as safe and effective treatment modalities for several dermatologic procedures, including skin tightening, hair and leg vein removal, acne scarring, skin rejuvenation, and wrinkle reduction. This article reviews the technology, clinical applications, and recent advances of RF and combined RF light/laser source technologies in aesthetic medicine.

  16. The works of Joseph and Michael Haydn in Ondřej Horník's collection

    Czech Academy of Sciences Publication Activity Database

    Freemanová, Michaela

    2017-01-01

    Roč. 9, 1-2 (2017), s. 14-23 ISSN 1803-7828 Institutional support: RVO:68378076 Keywords : music manuscripts * Joseph Haydn * Michael Haydn * Ondřej Horník's collection * church music Subject RIV: AL - Art, Architecture, Cultural Heritage OBOR OECD: Performing arts studies ( Music ology, Theater science, Dramaturgy) http://www.nm.cz/publikace/archiv.php?id=16

  17. Symetrie en energie des spectres de l'onde de densite de charge dans le 2-hydrogene seleniure de niobium

    Science.gov (United States)

    Behmand, Behnaz

    Les mecanismes qui menent a la supraconductivite dans les supraconducteurs a haute temperature critique sont encore aujourd'hui mal compris contrairement a ceux dans les supraconducteurs conventionnels. Dans les hauts-Tc, certaines modulations de la densite d'etats electroniques coexistant avec la phase supraconductrice ont ete observees, ce qui engendre des questionnements sur leur role dans la supraconductivite. En fait, plusieurs types de modulation de la densite d'etats electroniques existent, comme par exemple l'onde de densite de charge et l'onde de densite de paires. Ces deux modulations, d'origines differentes et mesurables avec la technique de spectroscopie par effet tunnel, peuvent etre differenciees avec une etude de leur symetrie. Ce memoire consistera donc a presenter l'etude de la symetrie de l'onde de densite de charge dans le 2H-NbSe2 qui est presente dans la phase supraconductrice a 300 mK. Par contre, certaines difficultes liees au principe de mesure, soit l'effet de normalisation, nuisent a l'identification de cette symetrie. La methode, pour contourner ce probleme sera alors l'element clef de ce travail.

  18. Modes of oscillation in radiofrequency Paul traps

    DEFF Research Database (Denmark)

    Landa, H.; Reznik, B.; Drewsen, M.

    2012-01-01

    We examine the time-dependent dynamics of ion crystals in radiofrequency traps. The problem of stable trapping of general threedimensional crystals is considered and the validity of the pseudopotential approximation is discussed. We analytically derive the micromotion amplitude of the ions...

  19. Pulsed Radiofrequency Ablation for Treating Sural Neuralgia.

    Science.gov (United States)

    Abd-Elsayed, Alaa; Jackson, Markus; Plovanich, Elizabeth

    2018-01-01

    Sural neuralgia is persistent pain in the distribution of the sural nerve that provides sensation to the lateral posterior corner of the leg, lateral foot, and fifth toe. Sural neuralgia is a rare condition but can be challenging to treat and can cause significant limitation. We present 2 cases of sural neuralgia resistant to conservative management that were effectively treated by pulsed radiofrequency ablation. A 65-year-old female developed sural neuralgia after a foot surgery and failed conservative management. She had successful sural nerve blocks, and pulsed radiofrequency ablation led to an 80% improvement in her pain. A 33-year-old female presented with sural neuralgia secondary to two falls. The patient had tried several conservative modalities with no success. We performed diagnostic blocks and pulsed radiofrequency ablation, and the patient reported 80% improvement in her pain. Pulsed radiofrequency ablation may be a safe and effective treatment for patients with sural neuralgia that does not respond to conservative therapy. However, studies are needed to elucidate its effectiveness and safety profile.

  20. Radiofrequency and microwave interactions between biomolecular systems

    Czech Academy of Sciences Publication Activity Database

    Kučera, Ondřej; Cifra, Michal

    2016-01-01

    Roč. 42, č. 1 (2016), s. 1-8 ISSN 0092-0606 R&D Projects: GA ČR(CZ) GA15-17102S Institutional support: RVO:67985882 Keywords : Cell signaling * Radiofrequency * Bioelectrodynamics Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.241, year: 2016

  1. Management of trigeminal neuralgia by radiofrequency ...

    African Journals Online (AJOL)

    The outcome depends on the type of TN with best results with classical idiopathic type. Also better results occurred with isolated V3 affection. The radiofrequency thermocoagulation of trigeminal nerve is a low risk, highly effective and minimally invasive procedure that should be started with in all cases of TN.

  2. Potential health risks due to telecommunications radiofrequency ...

    African Journals Online (AJOL)

    Background: The global system mobile telecommunications system (GSM) which was recently introduced in Nigeria is now being used by over 40 million people in Nigeria. The use of GSM is accompanied with exposure of the users to radiofrequency radiation (RFR), which if significant, may produce health hazards. This is ...

  3. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  4. Interactions between radiofrequency signals and living organisms

    International Nuclear Information System (INIS)

    Boudin, F.; Hours, M.; Lacronique, J.F.; Conil, E.; Hadjem, A.; El Habachi, A.; Wiart, K.; Mann, S.; Kundi, M.; Marc-Vergnes, J.P.; Roosli, M.; Mohler, E.; Frei, P.; Davis, Ch.C.; Balzano, Q.; Ait-Aissa, S.; Billaudel, B.; Poulletier De Gannes, F.; Hurtier, A.; Haro, E.; Taxile, M.; Veyret, B.; Lagroye, I.; Ait-Aissa, S.; Poulletier De Gannes, F.; Athane, A.; Veyret, B.; Lagroye, I.; Yardin, C.; Perrin, A.; Freire, M.; Bachelet, Ch.; Collin, A.; Pla, S.; Debouzy, J.C.; Leveque, Ph.; Van Nierop, L.E.; Huss, A.; Roosli, M.; Egger, M.; Calvez, M.; Salomon, D.

    2010-01-01

    This dossier is composed of 13 articles dealing with the interactions between radio-frequencies and living organisms. It is an overview of various scientific approaches to the field and is of interest for all citizens as the use of mobile phones is widely spread. In the first article it is shown how a model has been built to assess the distribution of the whole body exposure of the population. The second article reviews the state of the art in personal exposure measurements at radio-frequencies. The third article shows that the knowledge of the mechanism of action by which exposure increases the risk of health hazards is necessary. The fourth article shows that individual neuro-psychic factors take a prominent but maybe not unique, part in electromagnetic hypersensitivity. The fifth article shows that no evidence was found to link health disturbances of electromagnetic hypersensitive individuals with radiofrequency exposure. The sixth article shows that the wireless phone is not an athermal hazard to the brain. The seventh article shows that the in utero and post-natal exposure to Wi-Fi does not damage the brains of young rats. The eighth article concludes that recent studies provide no convincing proof of deleterious effects of radiofrequency exposure on the integrity of the blood-brain barrier for specific absorption rates up to 6 W/kg. The ninth article shows that no co-genotoxic effect of radiofrequency was found at levels of exposure that did not induce heating. The tenth article confirms that industry-sponsored studies were least likely to report results suggesting effects. The last article shows that general practitioners are increasingly questioned by their patients about the issue of electromagnetic waves. (A.C.)

  5. Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?

    Science.gov (United States)

    Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe

    2016-03-01

    Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P radiofrequency failure. Failure rate was lower with the multipolar technique for tumors radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  6. Realisation and subsequent improvements of a progressive wave laser. Application to the study of HFA fluorescence; Realisation et mise au point d'un laser UV a onde progressive. Application a l'etude de la fluorescence de l'hexafluoroacetone

    Energy Technology Data Exchange (ETDEWEB)

    Petit, Alain

    1976-05-26

    different pressures and several observation wavelengths. This work confirms Ware's results: the lifetime is independent, within the experimental errors, of the HFA pressure over the range from 20 to 400 torr and has a mean value of 87 ± 2 ns (compared to Ware's value of 84 ± 2 ns). The measurements have been completed at different observation wavelengths (band pass: Δλ 6 nm). We also have checked that the lifetime is the same over the entire emission band in this pressure range. At low pressures (≤ 10 torr), however, with a new experimental arrangement, it has been seen that the apparent fluorescence lifetime begins to decrease with pressure at certain observation wavelengths, ranging from 80 ns at 70 torr to 56 ns at 0,5 torr. Our results are in good agreement with the photochemical mechanism proposed by Ware. (author) [French] Waynant, Shipman, Hogdson et Schafer ont recemment montre qu'il etait possible, en excitant un gaz avec une decharge electrique transversale et progressive, d'obtenir des emissions laser dans l'UV et l'UV lointain de courte duree. Ce dispositif experimental est connu sous le nom de laser a onde progressive. Jusqu'a present avec ce type de laser, des emissions stimulees ont pu etre observees dans les gaz suivants: N{sub 2} (C{sup 3}πu → B{sup 3}πg), CO(A{sup 1}π → X{sup 1}Σ), H{sub 2}[B{sup 1}Σ → X{sup 1}Σ) et H{sub 2}(C{sup 1}π → X{sup 1}Σ) situees respectivement a 337, 193, 160 et 120 nm. La brievete des impulsions obtenues et les longueurs d'onde emises par ce type de laser nous ont incites a construire un tel laser et a etudier ses caracteristiques. Notre laser se compose principalement d'un canal de 24 cm, limite en largeur par deux electrodes en acier en forme de T entre lesquelles s'effectue la decharge. L'etude des caracteristiques de ce laser a azote donne les resultats suivants: une mesure a basse resolution de l'emission laser, due a la bande 0-0 du systeme 2{sup e} positif de l'azote situee a 337.1 nm, montre que l

  7. Wave Separation. Part Two: Applications La séparation des ondes. Deuxième partie : applications

    Directory of Open Access Journals (Sweden)

    Glangeaud F.

    2006-11-01

    clearly located it is in the f-k domain, the more efficient the filter is. The method is very cost-effective in CPU time. The KLT or SVD filter requires flattening the wave that is to be extracted, which must additionally be of greater amplitude. Filtering is carried out without any edge effect and the wave amplitude variations are preserved. It serves to separate the normal incidence wave from the other waves and the noise. The SMF filter (spectral matrix is expensive in CPU time It makes the hypothesis that the wave is locally stable and does not require the data to be flattened. It can be used to separate very close neighboring waves without resorting to restrictive a priori hypotheses. It gives a measurement of time delays and also provides a measurement of variations in amplitude and phase spectra during propagation. This measurement is much better than the one supplied by the Wiener method, since it operates on all the traces. Additionally, it is used to separate data into a signal space and a noise space. The parametric method is the most expensive as regards time. It is simple to implement and requires no flattening or preparation of data. It extracts the waves according to chosen parameters, especially time delays. It is particularly recommended in offset vertical seismic profiling where the slowness of upgoing waves is unknown. It is robust with respect to some input parameters if the noise is low in comparison to the signal that is to be extracted. Many applications to field data have illustrated the effectiveness of these wave separation techniques. However, application to a new type of data often requires performance to be monitored to choose the best method. L'identification d'ondes dans les sections utilisées en prospection sismique nécessite parfois de séparer ces ondes. La première partie de cet article a été consacrée au principe et aux méthodes de séparation d'ondes. Les méthodes de séparation d'ondes peuvent être classées en trois familles

  8. Traitement des diagraphies acoustiques. Deuxième partie : séparation des ondes en diagraphie acoustique Full-Waveform Acoustic Data Processing. Second Part: Wave Separation in Acoustic Well Logging

    OpenAIRE

    Gavin P.; Mari J. L.

    2006-01-01

    L'utilisation d'outils acoustiques à émetteurs-récepteurs multiples et enregistrement numérique permet de faire une microsismique de puits en utilisant des techniques de traitement dérivées du traitement sismique. Comme les enregistrements acoustiques sont composés de différents types d'ondes (ondes de volume réfractées ou réfléchies et ondes d'interface), une étape importante du traitement acoustique est la séparation des ondes. Cet article montre que la séparation des ondes peut être optimi...

  9. Fraxelated radiofrequency device for acne scars

    Science.gov (United States)

    Rao, Babar K.; Khokher, Sairah

    2012-09-01

    Acne scars can be improved with various treatments such as topical creams, chemical peels, dermal fillers, microdermabrasion, laser, and radiofrequency devices. Some of these treatments especially lasers and deep chemical peels can have significant side effects such as post inflammatory hyperpigmentation in darker skin types. Fraxelated RF Laser devices have been reported to have lower incidence of side effects in all skin phototypes. Nine patients between ages 18 and 35 of various skin phototypes were selected from a private practice and treated with a RF fraxelated device (E-matrix) for acne scars. Outcomes were measured by physician observation, subjective feedback received by patients, and comparison of before and after photographs. In this small group of patients with various skin phototypes, fraxelated radiofrequency device improved acne scars with minimal side effects and downtime.

  10. Arthroscopic surgery using radio-frequency electrocautery

    International Nuclear Information System (INIS)

    Takatsuka, Shigeyuki; Yoshida, Kan; Nakagawa, Kiyomasa; Yamamoto, Etsuhide; Kubota, Yoshiyuki; Narinobou, Masayoshi; Terai, Koichi; Hasegawa, Hiroshi

    2008-01-01

    Arthroscopic surgery using radio-frequency electrocautery was carried out on 23 temporomandibular joints (TMJs) in 13 patients. Because these patients did not respond to conservative therapy, surgery was indicated. Preoperative MRI showed anterior disc displacement without reduction in all patients. Disturbed translation was also recognized in all of the discs and mandibular condyles. Intraoperative arthroscopic examination showed severe fibrous adhesion in the upper joint compartment and disc displacement. Four joints showed perforation between the disc and retrodiscal tissue. Postoperative findings included an increased range of vertical maximal mouth opening and decreased pain on mandibular movement. Analyses of postoperative MRI indicated recovery of disc and condylar translation. These results suggested that the introduction of arthroscopic surgery using radiofrequency electrocautery would significantly reduce the number of patients with osteoarthritic TMJ disorders. (author)

  11. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  12. Trauma-Related Guilt Mediates the Relationship between Posttraumatic Stress Disorder and Suicidal Ideation in OEF/OIF/OND Veterans.

    Science.gov (United States)

    Tripp, Jessica C; McDevitt-Murphy, Meghan E

    2017-02-01

    Posttraumatic stress disorder (PTSD) and trauma-related guilt are risk factors for suicidal ideation (SI) in veterans. Components of trauma-related guilt were examined as serial mediators of the relationship between PTSD and SI. In a sample of 53 OEF/OIF/OND combat veterans, PTSD had an indirect effect on SI through a serial mediation chain of guilt cognitions, distress, and global guilt, suggesting that trauma-related guilt via cognitions, distress, and global guilt is a pathway from PTSD to SI. Attention should be given to assessing and addressing trauma-related guilt in veterans experiencing PTSD to prevent SI. © 2016 The American Association of Suicidology.

  13. Effect of Radiofrequency Endometrial Ablation on Dysmenorrhea.

    Science.gov (United States)

    Wyatt, Sabrina N; Banahan, Taylor; Tang, Ying; Nadendla, Kavita; Szychowski, Jeff M; Jenkins, Todd R

    To examine rates of dysmenorrhea after radiofrequency endometrial ablation in patients with and without known dysmenorrhea symptoms prior to the procedure in a diverse population. Retrospective cohort study (Canadian Task Force classification II-2). Academic gynecology practice. A total of 307 women underwent endometrial ablation between 2007 and 2013 at our institution. Patients who had preoperative and postoperative pain symptom assessments as well as a description of pain timing recorded were included in our analysis. Exclusion criteria were age dysmenorrhea was evaluated. Demographic information and other outcome variables were used to evaluate factors associated with resolution of dysmenorrhea. A total of 307 patients who underwent radiofrequency endometrial ablation were identified. After exclusions, 296 charts were examined, and 144 patients met our enrollment criteria. The mean age of the study cohort was 45.4 ± 6.2 years; 57 patients (40%) were African American, 16 (11%) had a body mass index (BMI) > 40, and 41 (29%) were of normal weight. Preoperative dysmenorrhea was reported by 100 patients (69%); 48 of these patients (48%) experienced resolution of symptoms postoperatively. Only 3 of the 44 patients (7%) without preoperative dysmenorrhea reported new-onset dysmenorrhea postoperatively. Significantly fewer patients had dysmenorrhea after compared to before radiofrequency ablation (55 of 144 [38%] vs 100 of 144 [69%]; p dysmenorrhea after ablation was associated with reduction in bleeding volume (p = .048) but not with a reduction in frequency of bleeding (p = .12). Approximately one-half of women who undergo radiofrequency endometrial ablation to treat heavy menstrual bleeding who also have preoperative dysmenorrhea exhibit documented pain resolution after the procedure. Resolution of dysmenorrhea is more likely if menstrual flow volume is decreased postprocedure. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  14. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  15. Issues in epidemiological studies of radiofrequency workers

    International Nuclear Information System (INIS)

    Hocking, B.

    1985-01-01

    The paper reviews some of the issues in a proposed epidemiological study of radiofrequency workers. First a few other epidemiological studies are discussed to illustrate some of the common problems such as inadequate definition of effects and/or exposure. Then technical problems in determining dosage and responses as well as study design are reviewed, and finally the administrative aspects of ethics, industrial relations and costs are considered

  16. ROLE OF RADIOFREQUENCY ABLATION IN ADENOMA SEBACEUM

    Directory of Open Access Journals (Sweden)

    Ch. Madh

    2016-03-01

    Full Text Available Adenoma sebaceum, pathognomonic of tuberous sclerosis, are tiny angiofibromas which commonly occur over central part of face. Recurrence after treatment is common and hence a need for inexpensive, safe and efficient treatment is required. Radiofrequency ablation is a safe and an economical procedure and has been known to cause less scarring with good aesthetic results compared to other ablative methods such as electrocautery.

  17. Radiofrequency amplifier based on a DC superconducting quantum interference device

    International Nuclear Information System (INIS)

    Martinis, J.M.; Hilbert, C.; Clarke, J.

    1986-01-01

    A method is described of amplifying a radiofrequency signal consisting of: disposing a single symmetrically biased dc SQUID and an input coil within a superconducting shield, the dc SQUID having a superconducting ring interrupted by two shunted Josephson junctions, and the input coil being inductively coupled solely to the ring of the single SQUID, establishing a constant magnetic flux threading the SQUID ring, applying the radiofrequency signal to the input coil from outside of the superconducting shield, obtaining an amplified radiofrequency signal solely from across the ring of the single SQUID, transmitting the amplified radiofrequency signal from across the SQUID ring to the outside of the superconducting shield

  18. Radiofrequency initiation and radiofrequency sustainment of laser initiated seeded high pressure plasma

    International Nuclear Information System (INIS)

    Paller, Eric S.; Scharer, John E.; Akhtar, Kamran; Kelly, Kurt; Ding, Guowen

    2001-01-01

    We examine radiofrequency initiation of high pressure(1-70 Torr) inductive plasma discharges in argon, nitrogen, air and organic seed gas mixtures. Millimeter wave interferometry, optical emission and antenna wave impedance measurements for double half-turn helix and helical inductive antennas are used to interpret the rf/plasma coupling, measure the densities in the range of 10 12 cm -3 and analyze the ionization and excited states of the gas mixtures. We have also carried out 193 nm excimer laser initiation of an organic gas seed plasma which is sustained at higher pressures(150 Torr) by radiofrequency coupling at 2.8 kW power levels

  19. Effect of radiofrequency on capacitance of low density plasma sheath

    International Nuclear Information System (INIS)

    Carneiro, L.T.; Cunha Rapozo, C. da

    1988-01-01

    It is shown that the influence of induced radiofrequency potential (V RF ) modifies the Bohm theory on ion saturation current, measured with Langmuir probes. The effect of radiofrequency potential on diode type plasma sheath resonance is also investigated. (M.C.K.)

  20. 77 FR 43535 - Grantee Codes for Certified Radiofrequency Equipment

    Science.gov (United States)

    2012-07-25

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 2 [FCC 12-60] Grantee Codes for Certified Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: This document... authorization program for radiofrequency (RF) devices under part 2 of its rules. This program is one of the...

  1. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  2. Level of Radiofrequency (RF) Radiations from GSM Base Stations ...

    African Journals Online (AJOL)

    Levels of radiofrequency radiations around two global systems for mobile communication (GSM) base stations located in the vicinity of a residential quarter and workplace complex were measured. The effects of the radiofrequency radiations on albino mice placed in exposure cages and located around the base stations ...

  3. Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Roman-Gonzalez, Javier; Johnson, Susan B

    2004-01-01

    INTRODUCTION: Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during...

  4. Occupational exposure to radiofrequency fields in antenna towers

    International Nuclear Information System (INIS)

    Alanko, T.; Hietanen, M.

    2007-01-01

    Exposure of workers to radiofrequency fields was assessed in two medium-sized antenna towers. Towers had transmitting antennas from different networks, e.g. mobile phone networks, radio and digital TV sub-stations and amateur radio. The levels of radiofrequency fields were measured close to the ladders of the towers. All measured values were below ICNIRP occupational reference levels. (authors)

  5. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  6. Active stabilization of ion trap radiofrequency potentials

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, K. G.; Wong-Campos, J. D.; Restelli, A.; Landsman, K. A.; Neyenhuis, B.; Mizrahi, J.; Monroe, C. [Joint Quantum Institute and University of Maryland Department of Physics, College Park, Maryland 20742 (United States)

    2016-05-15

    We actively stabilize the harmonic oscillation frequency of a laser-cooled atomic ion confined in a radiofrequency (rf) Paul trap by sampling and rectifying the high voltage rf applied to the trap electrodes. We are able to stabilize the 1 MHz atomic oscillation frequency to be better than 10 Hz or 10 ppm. This represents a suppression of ambient noise on the rf circuit by 34 dB. This technique could impact the sensitivity of ion trap mass spectrometry and the fidelity of quantum operations in ion trap quantum information applications.

  7. Ion transmission in a linear radiofrequency spectrometer

    International Nuclear Information System (INIS)

    Gomet, J.-C.

    1975-01-01

    A linear radiofrequency spectrometer is used for the purpose of experimental determination of the absolute ionization cross sections of various ions obtained by electron impact on polyatomic molecules. The transmission of the apparatus is studied: it does not only depend on the mass resolution of the spectrometer, but also on the nature of ions. It is affected by charge transfers, especially for the parent ions. An empiric way of correction of the apparatus function is given which allows the use at 10 -6 Torr [fr

  8. Radiofrequency Energy and Electrode Proximity Influences Stereoelectroencephalography-Guided Radiofrequency Thermocoagulation Lesion Size: An In Vitro Study with Clinical Correlation.

    Science.gov (United States)

    Staudt, Michael D; Maturu, Sarita; Miller, Jonathan P

    2018-02-16

    Radiofrequency thermocoagulation of epileptogenic foci via stereoelectroencephalography (SEEG) electrodes has been suggested as a treatment for medically intractable epilepsy, but reported outcomes have been suboptimal, possibly because lesions generated using conventional high-energy radiofrequency parameters are relatively small. To describe a technique of delivering low energy across separate SEEG electrodes in order to create large confluent radiofrequency lesions. The size and configuration of radiofrequency lesions using different radiofrequency intensity and interelectrode distance was assessed in egg whites. Magnetic resonance images (MRI) from 3 patients who had undergone radiofrequency lesion creation were evaluated to determine the contribution of lesion intensity and electrode separation on lesion size. Electroencephalography, MRI, and clinical data were assessed before and after lesion creation. Both in Vitro and in Vivo analysis revealed that less energy paradoxically produced larger lesions, with the largest possible lesions produced when radiofrequency power was applied for long duration at less than 3 W. Linear separation of electrodes also contributed to lesion size, with largest lesions produced when electrodes were separated by a linear distance of between 5 and 12 mm. Clinical lesions produced using these parameters were large and resulted in improvement in interictal and ictal activity. Radiofrequency lesions produced using low-energy delivery between SEEG electrodes in close proximity can produce a large lesion. These findings might have advantages for treatment of focal epilepsy.

  9. Influence des conditions initiales sur l'évolution d'une onde de choc induite par impulsion laser

    OpenAIRE

    Cottet , F.; Romain , J.P.

    1983-01-01

    L'évolution d'un choc de forte amplitude induit par une impulsion laser dans une cible solide est décrite à l'aide d'un modèle hydrodynamique, précisant un modèle antérieur par la prise en compte du déplacement de la surface avant de la cible sous l'effet de la pression d'ablation. Ce modèle est également utilisé pour étudier l'influence du profil initial de pression sur l'amortissement de l'onde de choc au cours de sa propagation.

  10. Neurohumoral indicators of efficacy radiofrequency cardiac denervation

    Energy Technology Data Exchange (ETDEWEB)

    Evtushenko, A. V., E-mail: ave@cardio-tomsk.ru; Evtushenko, V. V. [National Research Tomsk State University, Tomsk (Russian Federation); Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Saushkina, Yu. V.; Gusakova, A. M.; Suslova, T. E.; Dymbrylova, O. N.; Smyshlyaev, K. A.; Kurlov, I. O. [Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Lishmanov, Yu. B.; Anfinogenova, Ya. D. [National Research Tomsk Polytechnic University, Tomsk (Russian Federation); Federal State Budgetary Scientific Institution “Research Institute for Cardiology”, Tomsk (Russian Federation); Sergeevichev, D. S. [Academician E.N. Meshalkin State Research Institute of Circulation Pathology, Novosibirsk (Russian Federation); Bykov, A. N.; Syryamkin, V. I.; Kistenev, Yu. V. [National Research Tomsk State University, Tomsk (Russian Federation); Lotkov, A. I. [Institute of Strength Physics and Materials Science of the Siberian Branch of the RAS, Tomsk (Russian Federation); Pokushalov, E. A.

    2015-11-17

    In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

  11. Radiofrequency spark chambers and delay line resonators

    International Nuclear Information System (INIS)

    Sayag, Jacques

    1971-01-01

    According to a suggestion of A. Kastler, a spark chamber was excited by an undamped radiofrequency pulse and tracks about 1 mm wide obtained; the result was interpreted by computation of the coefficients of electronic amplification and partial ambipolar diffusion. This work led us to the construction of a new fast triggering undamped wave-train generator of very high tension (patent taken out by the C.E.A. under the no.: EN 7 134 650 the 27.9.1971). Since this apparatus uses a resonant storage line, its design implied a precise knowledge of high impedance delay lines. The experimental radiofrequency spectra of the input impedance of opened or short-circuited lines were plotted completely and analysed by the circuits theory, new measuring methods were established, dispersion relations accurately checked and the equivalence of the formulas, within the third order, with theses of Debye's Dipolar Absorption demonstrated. General properties of Hilbert's transform were also investigated. From the experimental point of view, the electromagnetic energy storage process was extended to the case of a liquid nitrogen-immersed resonant delay line. The good behavior of the cryogenic experiment, where the main difficulty of icing was overcame by the construction of special electrodes, offers great promise for extrapolation to superconductivity. (author) [fr

  12. A sheath model for arbitrary radiofrequency waveforms

    Science.gov (United States)

    Turner, M. M.; Chabert, Pascal

    2012-10-01

    The sheath is often the most important region of a rf plasma, because discharge impedance, power absorption and ion acceleration are critically affected by the behaviour of the sheath. Consequently, models of the sheath are central to any understanding of the physics of rf plasmas. Lieberman has supplied an analytical model for a radio-frequency sheath driven by a single frequency, but in recent years interest has been increasing in radio-frequency discharges excited by increasingly complex wave forms. There has been limited success in generalizing the Lieberman model in this direction, because of mathematical complexities. So there is essentially no sheath model available to describe many modern experiments. In this paper we present a new analytical sheath model, based on a simpler mathematical framework than that of Lieberman. For the single frequency case, this model yields scaling laws that are identical in form to those of Lieberman, differing only by numerical coefficients close to one. However, the new model may be straightforwardly solved for arbitrary current waveforms, and may be used to derive scaling laws for such complex waveforms. In this paper, we will describe the model and present some illustrative examples.

  13. ETUDE DE L'ACTION D'UNE ONDE ELECTROMAGNETIQUE POLARISEE CIRCULAIREMENT SUR UN ATOME A DEUX NIVEAUX PAR LE FORMALISME DES INTEGRALES DE CHEMINS

    Directory of Open Access Journals (Sweden)

    M AOUACHRIA

    2002-12-01

    Full Text Available L'action d'une onde électromagnétique polarisée circulairement sur un atome à deux niveaux est étudiée par le formalisme des intégrales de chemins. L'utilisation de l'espace des phases et de certaines rotations dans l'espace des états cohérents ont permis de simplifier énormément les calculs. Les fonctions d'onde correspondantes ont été retrouvées exactement.

  14. Image-guided radiofrequency ablation of renal cell carcinoma

    International Nuclear Information System (INIS)

    Boss, Andreas; Clasen, Stephan; Pereira, Philippe L.; Kuczyk, Markus; Schick, Fritz

    2007-01-01

    The incidence of renal cell carcinoma is rising with the increased number of incidental detection of small tumours. During the past few years, percutaneous imaging-guided radiofrequency ablation has evolved as a minimally invasive treatment of small unresectable renal tumours offering reduced patient morbidity and overall health care costs. In radiofrequency ablation, thermal energy is deposited into a targeted tumour by means of a radiofrequency applicator. In recent studies, radiofrequency ablation was shown to be an effective and safe modality for local destruction of renal cell carcinoma. Radiofrequency applicator navigation can be performed via ultrasound, computed tomography or magnetic resonance guidance; however, ultrasound seems less favourable because of the absence of monitoring capabilities during ablation. On-line monitoring of treatment outcome can only be performed with magnetic resonance imaging giving the possibility of eventual applicator repositioning to ablate visible residual tumour tissue. Long-term follow-up is crucial to assess completeness of tumour ablation. New developments in ablation technology and radiological equipment will further increase the indication field for radiofrequency ablation of renal cell carcinoma. Altogether, radiofrequency ablation seems to be a promising new modality for the minimally invasive treatment of renal cell carcinoma, which was demonstrated to exhibit high short-term effectiveness. (orig.)

  15. Estudio Te\\'orico del espectro de emisi\\'on para un sistema microcavidad-punto cu\\'antico en una aproximaci\\'on de campo medio (Theoretical study of emission spectrum for a quantum dot-microcavity system in a mean field approximation)

    OpenAIRE

    Rojas-Arias, Juan S.; Rodriguez, B.; Vinck-Posada, Herbert

    2015-01-01

    En este trabajo, se obtiene una expresi\\'on num\\'erica para calcular el espectro de emisi\\'on de un sistema microcavidad-punto cu\\'antico usando una teor\\'ia de campo medio en el formalismo de la matriz densidad. El sistema modelado es un micropilar semiconductor que contiene un \\'unico punto cu\\'antico en el interior de la microcavidad, este sistema presenta p\\'erdida de fotones a trav\\'es de los espejos de la cavidad y bombeo de excitones al punto cu\\'antico. Obtenemos una ecuaci\\'on maestr...

  16. Clinical application and developmental trend of radiofrequency ablation technology

    International Nuclear Information System (INIS)

    Chen Dongfeng

    2009-01-01

    For recent two decades, radiofrequency ablation technology has made great progress in the field of the treatment for neoplasm. At the very beginning, radiofrequency ablation was adopted in treating the hepatic carcinoma, and since then it has been gradually practiced in treating malignancies of lung, bone, kidney, breast, prostate and other solid tumors. Statistical report of the year 2008 has indicated that in the aspect of similar therapeutic measures radiofrequency ablation therapy for tumors holds a 9% market share. Moreover, in the coming years the clinical use of this kind of therapy for tumors will be steadily increasing by 13% every year. (authors)

  17. Radiofrequency contact currents: sensory responses and dosimetry

    International Nuclear Information System (INIS)

    Kavet, Robert; Tell, R.A.; Olsen, R.G.

    2014-01-01

    The process of setting science-based exposure standards (or guidelines) for radiofrequency (RF) contact current exposure has been disadvantaged by a lack of relevant data. The authors first review the essential features and results of the available studies and illustrate the apparent discrepancies among them. Then, they examine the manner in which current was administered in these studies and suggest as to how the physical relationship of a contacting finger to the current electrode may play a role in affecting sensory thresholds specific to those configurations. A major factor in this analysis relates to whether current density is uniformly distributed across the contact area or whether an electrode's 'edge effects' enhance currents with a net effect of decreasing apparent thresholds, when expressed as the bulk current entering a subject. For an exposure with a clear hazard potential, thresholds of human sensory response to RF currents require further investigation. (authors)

  18. LAPAROSCOPIC NEPHRECTOMY USING RADIOFREQUENCY THERMAL ABLATION

    Directory of Open Access Journals (Sweden)

    B. Ya. Alekseev

    2012-01-01

    Full Text Available The wide use of current diagnostic techniques, such as ultrasound study, computed tomography, and magnetic resonance imaging, has led to significantly increased detection rates for disease in its early stages. This gave rise to a change in the standards for the treatment of locally advanced renal cell carcinoma (RCC. Laparoscopic nephrectomy (LN has recently become the standard treatment of locally advanced RCC in the clinics having much experience with laparoscopic surgery. The chief drawback of LN is difficulties in maintaining intraoperative hemostasis and a need for creating renal tissue ischemia. The paper gives the intermediate results of application of the new procedure of LN using radiofrequency thermal ablation in patients with non-ischemic early-stage RCC.

  19. Emerging indications of endoscopic radiofrequency ablation

    Science.gov (United States)

    Becq, Aymeric; Camus, Marine; Rahmi, Gabriel; de Parades, Vincent; Marteau, Philippe

    2015-01-01

    Introduction Radiofrequency ablation (RFA) is a well-validated treatment of dysplastic Barrett's esophagus. Other indications of endoscopic RFA are under evaluation. Results Four prospective studies (total 69 patients) have shown that RFA achieved complete remission of early esophageal squamous intra-epithelial neoplasia at a rate of 80%, but with a substantial risk of stricture. In the setting of gastric antral vascular ectasia, two prospective monocenter studies, and a retrospective multicenter study, (total 51 patients), suggest that RFA is efficacious in terms of reducing transfusion dependency. In the setting of chronic hemorrhagic radiation proctopathy, a prospective monocenter study and a retrospective multicenter study (total 56 patients) suggest that RFA is an efficient treatment. A retrospective comparative study (64 patients) suggests that RFA improves stents patency in malignant biliary strictures. Conclusions Endoscopic RFA is an upcoming treatment modality in early esophageal squamous intra-epithelial neoplasia, as well as in gastric, rectal, and biliary diseases. PMID:26279839

  20. Radiofrequency encoded angular-resolved light scattering

    DEFF Research Database (Denmark)

    Buckley, Brandon W.; Akbari, Najva; Diebold, Eric D.

    2015-01-01

    The sensitive, specific, and label-free classification of microscopic cells and organisms is one of the outstanding problems in biology. Today, instruments such as the flow cytometer use a combination of light scatter measurements at two distinct angles to infer the size and internal complexity...... of cells at rates of more than 10,000 per second. However, by examining the entire angular light scattering spectrum it is possible to classify cells with higher resolution and specificity. Current approaches to performing these angular spectrum measurements all have significant throughput limitations...... Encoded Angular-resolved Light Scattering (REALS), this technique multiplexes angular light scattering in the radiofrequency domain, such that a single photodetector captures the entire scattering spectrum from a particle over approximately 100 discrete incident angles on a single shot basis. As a proof...

  1. Optical generation of radio-frequency power

    International Nuclear Information System (INIS)

    Hietala, V.M.; Vawter, G.A.; Brennan, T.M.; Hammons, B.E.; Meyer, W.J.

    1994-11-01

    An optical technique for high-power radio-frequency (RF) signal generation is described. The technique uses a unique photodetector based on a traveling-wave design driven by an appropriately modulated light source. The traveling-wave photodetector (TWPD) exhibits simultaneously a theoretical quantum efficiency approaching 100 % and a very large electrical bandwidth. Additionally, it is capable of dissipating the high-power levels required for the RF generation technique. The modulated light source is formed by either the beating together of two lasers or by the direct modulation of a light source. A system example is given which predicts RF power levels of 100's of mW's at millimeter wave frequencies with a theoretical ''wall-plug'' efficiency approaching 34%

  2. Radiofrequency identification for inventory in neurointerventional practice.

    Science.gov (United States)

    Byers, Ernest; Gomez, Max A; Sheridan, Robert M; Orr, Nelson W; Hirsch, Joshua A

    2011-03-01

    Implementations of radiofrequency identification (RFID) systems within hospital settings are not unique or without controversy. To date, little consideration has been given to use of this technology in clinical interventional radiologic practice. The potential financial advantages coupled with benefits to quality and safety and increases in staff satisfaction are considerable. The authors outline these advantages by enabling readers to broadly consider the systemic perspective of implementing RFID technology with an associated vision toward downstream growth. Furthermore, the authors demonstrate the benefits of RFID technology integration in reducing cost and increasing quality assurance and the on-time delivery of services. Implementing RFID requires commitment from frontline technologist staff members to work collaboratively with management and external vendors. Ultimately, the authors believe this technology can positively influence patient care. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Radiofrequency Electromagnetic Field Map of Timisoara

    Science.gov (United States)

    Stefu, N.; Solyom, I.; Arama, A.

    2015-12-01

    There are many electromagnetic field (EMF) sources nowadays acting simultaneously, especially in urban areas, making the theoretical estimation of electromagnetic power at ground level very difficult. This paper reports on EMF maps built with measurements collected in Timisoara, at various radiofrequencies. A grid of 15×15 squares was built (approximate resolution 400m x 400m) and measurements of the average and maximum values of the electric field E, magnetic field H and total power density S at 0.9, 1.8 and 2.4 GHz were collected in every node of the grid. Positions of the nodes in terms of latitude and longitude were also collected. Maps were built presenting the spatial distribution of the measured quantities over Timisoara. Potential influences of EMF on public health are discussed.

  4. Freescale Sdn Bhd: Monitoring Radiofrequency Assessment

    International Nuclear Information System (INIS)

    Wan Saffiey Wan Abdullah; Noor Ezati Shuib; Rozaimah Abdul Rahim; Pasupathy, E.; Muhammad Yusri Yahaya

    2015-01-01

    Freescale Semiconductor (M) Sdn Bhd, requested the assistance of Malaysian Nuclear Agency (Nuclear Malaysia) to conduct an electromagnetic radiation (Radiofrequency Radiation) measurements around its facilities at Freescale Semiconductor (M) Sdn Bhd, 2, Jalan SS8/2, Sungai Wai Free Industrial Zone, 47300 Petaling Jaya, Selangor. Nuclear Agency Non-Ionising Radiation (NIR) Group carried out the measurement on 30th July 2012. In carrying out the work, the Group was assisted by Mr Daniel. The main objectives of the measurement were to assess the presence of electromagnetic radiation (RF field) in an accessible work places within and around the facilities and to advise the company on outcomes of the assessment and measurement based on international recommendations of standard guidelines issued by Malaysian Communication and Multimedia Commission (MCMC) and International Commission on Non-Ionising Radiation Protection (ICNIRP). (author)

  5. Radio-frequency quadrupole linear accelerator

    International Nuclear Information System (INIS)

    Wangler, T.P.; Stokes, R.H.

    1980-01-01

    The radio-frequency quadrupole (RFQ) is a new linear accelerator concept in which rf electric fields are used to focus, bunch, and accelerate the beam. Because the RFQ can provide strong focusing at low velocities, it can capture a high-current dc ion beam from a low-voltage source and accelerate it to an energy of 1 MeV/nucleon within a distance of a few meters. A recent experimental test at the Los Alamos Scientific Laboratory (LASL) has confirmed the expected performance of this structure and has stimulated interest in a wide variety of applications. The general properties of the RFQ are reviewed and examples of applications of this new accelerator are presented

  6. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on ...

    African Journals Online (AJOL)

    olayemitoyin

    Summary: Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed ... mobile phones on autonomic modulation of the heart. ..... Electrocardiogram and Its Technology. J. Am.

  7. Radio-frequency wave enhanced runaway production rate

    International Nuclear Information System (INIS)

    Chan, V.S.; McClain, F.W.

    1983-01-01

    Enhancement of runaway electron production (over that of an Ohmic discharge) can be achieved by the addition of radio-frequency waves. This effect is studied analytically and numerically using a two-dimensional Fokker--Planck quasilinear equation

  8. Administrative norms on radiofrequency radiation for occupationally exposed persons

    International Nuclear Information System (INIS)

    Saxeboel, G.

    1982-01-01

    The report presents a proposal for administrative norms on radiofrequency (RF) radiation for occupationally exposed persons. The norms establish maximum allowable field exposure in a frequency range from 1 MHz too 300 GHz. (RF)

  9. Ion-storage in radiofrequency electric quadrupole field

    International Nuclear Information System (INIS)

    Gheorghe, V.

    1976-01-01

    The confinement of charged particles in a quadrupole radiofrequency electric field are presented. The stability diagrams and phase space trajectories for the quadrupole mass spectrometer and for the ion trap are represented and their main characteristics are discussed. (author)

  10. Process for selected gas oxide removal by radiofrequency catalysts

    Science.gov (United States)

    Cha, Chang Y.

    1993-01-01

    This process to remove gas oxides from flue gas utilizes adsorption on a char bed subsequently followed by radiofrequency catalysis enhancing such removal through selected reactions. Common gas oxides include SO.sub.2 and NO.sub.x.

  11. Paying attention to radiofrequency ablation therapy for neoplasms

    International Nuclear Information System (INIS)

    Wang Zhongming; Li Linsun

    2010-01-01

    Radiofrequency ablation is an effective treatment for malignant tumors. With the development of imaging technique, it has been widely used in treating different kinds of malignant tumors, such as liver cancer, lung cancer, kidney carcinoma, etc. Radiofrequency ablation has a lot of advantages. As a minimally-invasive, safe and effective treatment with less sufferings and fewer complications, this technique has attracted more and more attention of the experts both at home and abroad. (authors)

  12. Eye examinations of laser and radiofrequency radiation workers

    International Nuclear Information System (INIS)

    Hocking, B.

    1988-01-01

    There are a growing number of uses of lasers and radiofrequency radiation in industry. Because these radiations may lead to various ocular effects, examinations of the eye are required for laser and radiofrequency workers as part of safe working practices. Various issues concerning these examinations are raised for discussion including: handling personal data, placement criteria, data collection, quality control, control data, the load on service providers, and costs

  13. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    International Nuclear Information System (INIS)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong

    1997-01-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed

  14. Treatment of Refractory Idiopathic Supraorbital Neuralgia Using Percutaneous Pulsed Radiofrequency.

    Science.gov (United States)

    Luo, Fang; Lu, Jingjing; Ji, Nan

    2018-02-26

    No ideal therapeutic method currently exists for refractory idiopathic supraorbital neuralgia patients who do not respond to conservative therapy, including medications and nerve blocks. Pulsed radiofrequency is a neuromodulation technique that does not produce sequelae of nerve damage after treatment. However, the efficacy of percutaneous pulsed radiofrequency for the treatment of refractory idiopathic supraorbital neuralgia is still not clear. The purpose of our study was to evaluate the efficacy and safety of pulsed radiofrequency treatment of the supraorbital nerve for refractory supraorbital neuralgia patients. We prospectively investigated the long-term effects of ultrasound-guided percutaneous pulsed radiofrequency in the treatment of 22 refractory idiopathic supraorbital neuralgia patients. A reduction in the verbal pain numeric rating scale score of more than 50% was used as the standard of effectiveness. The effectiveness rates at different time points within 2 years were calculated. After a single pulsed radiofrequency treatment, the effectiveness rate at 1 and 3 months was 77%, and the rates at 6 months, 1 year, and 2 years were 73%, 64%, and 50%, respectively. Except for a small portion of patients (23%) who experienced mild upper eyelid ecchymosis that gradually disappeared after approximately 2 weeks, no obvious complications were observed. In conclusion, the results of our study demonstrate that for patients with refractory idiopathic supraorbital neuralgia, percutaneous pulsed radiofrequency may be an effective and safe treatment choice. © 2018 World Institute of Pain.

  15. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1997-08-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed.

  16. Transitar para onde? Monstruosidade, (despatologização, (insegurança social e identidades transgêneras

    Directory of Open Access Journals (Sweden)

    Jorge Leite Junior

    2012-05-01

    Full Text Available http://dx.doi.org/10.1590/S0104-026X2012000200016 O objetivo deste artigo é discutir a categoria “monstro” e sua íntima relação com apatologização e/ou criminalização de determinadas pessoas vistas como ‘desviantes sexuais’,em especial travestis, transexuais e intersexuais. No início do século XXI, com o questionamentoda autoridade médica, a politização dos movimentos sociais de travestis e transexuais e abatalha por sua despatologização, para onde se encaminham os “transtornos” de sexo ougênero, as “parafilias” e as “perversões” com toda a persistente estigmatização a elas referidas?Voltarão a ser redimensionadas como algo potencialmente perigoso através da cada vez maisabrangente cultura da segurança?

  17. Teoria dell'elettromagnetismo fenomeni e leggi fondamentali : energia dei campi e delle distribuzioni di carica, applicazioni di meccanica analitica e statistica, teoria della relatività, emissione e propagazione di onde elettromagnetiche

    CERN Document Server

    Tenaglia, Livio

    1956-01-01

    Leggi fondamentali dell'elettromagnetismo ; le equazioni di Lagrange, di Hamilton e di Jacobi, il principio di Fermat ; applicazioni di meccanica analitica all'elettromagnetismo ; teoria statica dell'irraggiamento ; fondamenti di teoria della relatività ; propagazione delle onde elettromagnetiche proprietà elementari dei conduttori ; emissione di onde elettromagnetiche ; richiami analitici ; unità di misura per le grandezze del campo elettromagnetico.

  18. Conventional Radiofrequency Thermocoagulation vs Pulsed Radiofrequency Neuromodulation of Ganglion Impar in Chronic Perineal Pain of Nononcological Origin.

    Science.gov (United States)

    Usmani, Hammad; Dureja, G P; Andleeb, Roshan; Tauheed, Nazia; Asif, Naiyer

    2018-01-10

    Chronic nononcological perineal pain has been effectively managed by ganglion Impar block. Chemical neurolysis, cryoablation, and radiofrequency ablation have been the accepted methods of blockade. Recently, pulsed radiofrequency, a novel variant of conventional radiofrequency, has been used for this purpose. This was a prospective, randomized, double-blind study. Two different interventional pain management centers in India. To compare the efficacy of conventional radiofrequency and pulsed radiofrequency for gangliom Impar block. The patients were randomly allocated to one of two groups. In the conventional radiofrequency (CRF) group (N = 34), conventional radiofrequency ablation was done, and in the PRF pulsed radiofrequency (PRF) group (N = 31), pulsed radiofrequency ablation was done. After informed and written consent, fluoroscopy-guided ganglion Impar block was performed through the first intracoccygeal approach. The extent of pain relief was assessed by visual analog scale (VAS) at 24 hours, and at the first, third, and sixth weeks following the intervention. A questionnaire to evaluate subjective patient satisfaction was also used at each follow-up visit. In the CRF group, the mean VAS score decreased significantly from the baseline value at each follow-up visit. But in the PRF group, this decrease was insignificant except at 24-hour follow-up. Intergroup comparison also showed significantly better pain relief in the CRF group as compared with the PRF group. At the end of follow-up, 28 patients (82%) in the CRF group and four patients (13%) in the PRF group had excellent results, as assessed by the subjective patient satisfaction questionnaire. There was no complication in any patient of either study group, except for short-lived infection at the site of skin puncture in a few. Ganglion Impar block by conventional radiofrequency provided a significantly better quality of pain relief with no major side effects in patients with chronic

  19. Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection: ex vivo bovine liver

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Joon Koo; Kim, Se Hyung; Lee, Jae Young; Park, Hee Sun; Hur, Hurn; Choi, Byung Ihn; Shin, Kyung Sook

    2004-01-01

    We wished to compare the in-vitro efficiency of wet radiofrequency (RF) ablation with the efficiency of dry RF ablation and RF ablation with preinjection of NaCl solutions using excised bovine liver. Radiofrequency was applied to excised bovine livers in a monopolar mode for 10 minutes using a 200 W generator and a perfused-cooled electrode with or without injection or slow infusion of NaCl solutions. After placing the perfused-cooled electrode in the explanted liver, 50 ablation zones were created with five different regimens: group A; standard dry RF ablation, group B; RF ablation with 11 mL of 5% NaCl solution preinjection, group C; RF ablation with infusion of 11 mL of 5% NaCl solution at a rate of 1 mL/min, group D; RFA with 6 mL of 36% NaCl solution preinjection, group E; RF ablation with infusion of 6 mL of 36% NaCl solution at a rate of 0.5 mL/min. In groups C and E, infusion of the NaCl solutions was started 1 min before RF ablation and then maintained during RF ablation (wet RF ablation). During RF ablation, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in impedance, current and liver temperature during RF ablation were then compared between the groups. With injection or infusion of NaCl solutions, the mean initial tissue impedance prior to RF ablation was significantly less in groups B, C, D, and E (43-75 Ω) than for group A (80 Ω) (ρ 3 in group A; 12.4 ± 3.8 cm 3 in group B; 80.9 ± 9.9 cm 3 in group C; 45.3 ± 11.3 cm 3 in group D and 81.6 ± 8.6 cm 3 in group E. The tissue temperature measured at 15 mm from the electrode was higher in groups C, D and E than other groups (ρ < 0.05): 53 ± 12 .deg. C in group A, 42 ± 2 .deg. C in group B, 93 ± 8 .deg. C in group C; 79 ± 12 .deg. C in group D and 83 ± 8 .deg.C in group E. Wet RF ablation with 5% or 36% NaCl solutions shows better efficiency in creating a large ablation zone than does dry RF ablation or RF ablation with

  20. Wave Separation. Part One: Principle and Methods La séparation d'ondes. Première partie : Principes et méthodes

    Directory of Open Access Journals (Sweden)

    Mari J. L.

    2006-11-01

    Full Text Available This article is a practical review of the different wave separation methods used in seismic. A wave is described by its propagation vector and its wavelet. The first part of the article shows how the propagation vector can be used to define both the type of propagation (plane or nonplane wave and the characteristics of the medium (dispersive or faulted medium. Wave separation and wave-type identification can then be dealt with by studying the scalar product between two waves or between a wave and a reference model. The main filtering methods are described, in particular : f-k filtering, tau-p filtering, Karhunen-Loeve filtering and spectral matrix filtering. The efficiency of the different methods is assessed with synthetic data. The problem of extracting a wave from noise is also discussed and illustrated with a field example. The second part will be devoted to wave separation per se. The different methods described in the first part are applied to real data, in particular borehole survey seismic data. Special attention is given to the use of specific, less well-known methods such as spectral matrix filtering with adapted or constrained models. Cet article est une revue pratique des différentes méthodes de séparation d'ondes utilisées en sismique. Une onde est décrite par son vecteur de propagation et par son ondelette. La première partie montre comment le vecteur de propagation peut être utilisé à la fois pour définir le type de propagation (onde plane ou non plane et les caractéristiques du milieu (milieu dispersif ou faillé. La séparation d'ondes et l'identification d'un type d'onde peuvent alors être abordées par l'étude du produit scalaire entre deux ondes ou entre une onde et un modèle de référence. Les principales méthodes de filtrage sont décrites : notamment le filtrage (f, k, le filtrage (tau, p, le filtrage de Karhunen-Loève et le filtrage par la matrice interspectrale. L'efficacité des différentes m

  1. Onde calham os primos

    OpenAIRE

    Chalub, Fábio Augusto da Costa Carvalho

    2010-01-01

    Dizem que, uma vez, um grupo de estudantes se dirigiu a um eminente matemático russo, pedindo ajuda para resolver um somatório de números primos. "Quando será que vão perceber que números primos existem para multiplicar e não para somar?", respondeu-lhes. O que diria então do mais recente teorema no assunto? publishersversion published

  2. Percutaneous radiofrequency treatment for refractory anteromedial pain of osteoarthritic knees.

    Science.gov (United States)

    Ikeuchi, Masahiko; Ushida, Takahiro; Izumi, Masashi; Tani, Toshikazu

    2011-04-01

    Although severe knee osteoarthritis with refractory pain is commonly treated surgically, this is often not an option for patients with poor health status or unwillingness to undergo major surgery. We examined the efficacy of radiofrequency application to sensory nerves as a novel alternative treatment for refractory knee pain. This study was an open-label, nonrandomized, and controlled study. Patients complaining of refractory anteromedial knee pain associated with radiological osteoarthritis (moderate or severe) were included. They were assigned to one of two groups: those receiving radiofrequency thermocoagulation (N = 18) or those receiving nerve block (N = 17), depending on the time period that they were referred to the clinic. Radiofrequency current or local anesthetics was applied to the medial retinacular nerve and the infrapatellar branch of the saphenous nerve. Western Ontario McMaster Universities osteoarthritis index score, pain visual analog scale (VAS), and patient's global assessment were assessed with a minimum follow-up of 6 months.   Radiofrequency treatment significantly decreased knee pain as measured by VAS for 12 weeks compared with the control group. In terms of responders, more patients in the RF group responded to the treatment than in the control group. The differences were statistically significant at 4 weeks, 8 weeks, and 12 weeks in pain VAS. Eight patients (44%) treated with radiofrequency rated excellent or good but only three (18%) in the control group rated good, although the difference was not statistically significant. Some patients were able to benefit substantially from radiofrequency treatment. Even if its effective period is limited, radiofrequency application is a promising treatment to alleviate refractory anteromedial knee pain with osteoarthritis. Further experience and technical improvements are needed to establish its role in the management of knee osteoarthritis. Wiley Periodicals, Inc.

  3. Burner redesign for the reduction of the unburned particulate emission in thermal power stations of Comision Federal de Electricidad; Rediseno de quemadores para la reduccion de la emision de particulas inquemadas en centrales termicas de la Comisionon Federal de Electricidad

    Energy Technology Data Exchange (ETDEWEB)

    Huerta Espino, Mario; Espipnoza Garza, Jesus; Mani Gonzalez, Alejandro; Giles Alarcon, Armando; Pena Garcia, Adriana; Albarran Sanchez, Irma L; Mendez Aranda, Angel [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    2001-07-01

    In the presence of the increasing demand for reaching higher efficiencies and a smaller production of polluting emissions in combustion systems, studies focused to the optimization of the present designs of burners are required. The Comision Federal de Electricidad (CFE) and the Instituto de Investigaciones Electricas (IIE) have established a project that contemplates the redesign of burners in ten of its units of thermoelectric generation. In this work the redesign of the flame stabilizer or diffuser for the reduction of the unburned particulate emission is explained. The results of the modeling of a burner of rotational flow of steam generators of the CFE are shown, as well as the graphs of the contours of the recirculation zone generated by each diffuser without combustion and a figure of the velocity profile that is generated in front of the diffuser. In agreement with the results obtained in the aerodynamic evaluation of frontal burners of rotational flow, it is possible to established that the characteristics of the recirculation zone, generated by this type of burners, are related to geometric parameters of the diffuser that identify with the number of turns and the pressure drop, where it is necessary to look for designs that improve the conditions of the mixing process and combustion in the burner. [Spanish] Ante la creciente demanda por alcanzar mayores eficiencias y una menor produccion de emisiones contaminantes en sistemas de combustion, se requieren estudios enfocados a la optimizacion de los disenos actuales de quemadores. La Comision Federal de Electricidad (CFE) y el Instituto de Investigaciones Electricas (IIE) han establecido un proyecto que contempla el rediseno de quemadores en diez de sus unidades de generacion termoelectrica. En este trabajo se explica el rediseno del estabilizador de flama o difusor para la reduccion de la emision de particulas inquemadas. Se muestran los resultados de la modelacion de un quemador de flujo rotacional de

  4. Detecção de manchas de sangue pelo luminol onde houve entintamento das paredes – estudo de caso

    Directory of Open Access Journals (Sweden)

    Geraldo Elias Miranda

    2016-04-01

    Full Text Available O luminol é um teste presuntivo para detecção de manchas de sangue, muito sensível, efetivo e seletivo. O objetivo deste trabalho é avaliar a eficácia do luminol na detecção de sangue após o entintamento das paredes em um local onde ocorreu um homicídio. Os peritos se dirigiram para a casa do suspeito e com o uso de uma espátula metálica retiraram parte do revestimento da parede do quarto e após nova aplicação do luminol observaram a mancha branco-azulada, intensa e de duração típica de sangue latente. Os fragmentos retirados da parede foram enviados para o laboratório de DNA que confirmou tratar-se de sangue da vítima. A aplicação dessa técnica no caso em questão encontrando manchas de sangue sob a pintura ajudou a perícia a traçar a dinâmica do evento, ficando mais clara a posição da vítima quando foi alvejada com tiros pelo seu agressor além de ligar aquele local à vítima. O luminol não é capaz de detectar sangue que está sob a tinta da parede. A deteção do sangue latente somente ocorre quando a camada de tinta é retirada.

  5. Stepwise radiofrequency ablation of Barrett's esophagus preserves esophageal inner diameter, compliance, and motility

    NARCIS (Netherlands)

    Beaumont, H.; Gondrie, J. J.; McMahon, B. P.; Pouw, R. E.; Gregersen, H.; Bergman, J. J.; Boeckxstaens, G. E.

    2009-01-01

    Background and aim: Stepwise endoscopic circumferential and focal radiofrequency ablation is safe and effective for the eradication of Barrett's esophagus. In contrast to other techniques, radiofrequency ablation appears to avoid significant esophageal scarring or stenosis. Our aim was to evaluate

  6. Evaluation of radiofrequency dielectric heaters workers exposure

    International Nuclear Information System (INIS)

    Benes, M.; Del Frate, S.; Villalta, R.

    2008-01-01

    Radiofrequency dielectric heaters (RFDH) are widely used in the woodworking industry for gluing laminates by applying pressure and RF heating. The workers operating such equipment remain in the vicinity of the machinery all day and can therefore be exposed to considerable levels of electric and magnetic field at RFs. This work describes the method used to measure the strength of fields generated by this particular machinery. This procedure is based on current methods cited in the literature and introduces the necessary modifications to meet this specific case. In particular, as there is often a scarcity of technical data available relating to such heaters, it is suggested that a spectrum analyser be used for measurements in the frequencies domain. On the basis of the data obtained the norms of reference are established, the instrumentation to be used in successive stages determined as well as the identification of possible sources of interference from spurious signals. Furthermore, a mapping of the field strengths is presented and the means of determining the decay curve as a function of distance. This last type of measurement is done to estimate the effectiveness of grounding the machinery. The report ends with an estimate of the exposure of workers to electromagnetic fields and also some recommendations for reducing risk. (authors)

  7. Metallic implants and exposure to radiofrequency radiation

    International Nuclear Information System (INIS)

    Joyner, K.H.; Fleming, A.H.F.; MacFarlane, I.P.; Hocking, B.

    1988-01-01

    There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches 1 . The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in Telecom Australia, beginning with the general principles and then presenting a specific example discussion of a specific example

  8. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  9. Stochasticity and superadiabaticity in radiofrequency plasma heating

    International Nuclear Information System (INIS)

    Stix, T.H.

    1979-04-01

    In a plasma subject to radiofrequency fields, it is only the resonant particles - comprising just a minor portion of the total velocity distribution - which are strongly affected. Under near-fusion conditions, thermalization by Coulomb collisions is slow, and noncollisional stochasticity can play an important role in reshaping f(v). It is found that the common rf interactions, including Landau, cyclotron and transit-time damping, can be fitted in a unified manner by a simple two-step one-parameter (epsilon) mapping which can display collision-free stochastic or adiabatic (also called superadiabatic) behavior, depending on the choice of epsilon. The effect on the evolution of the space averaged f (x,v,t) is reasonably well described by a pseudo-stochastic diffusion function, D/sub PS/(v,epsilon) which is the quasilinear diffusion coefficient but with appropriate widening of the delta-function spikes. Coulomb collisions, leading to D/sub Coul/(v) which may be added and directly compared to D/sub PS/(v,epsilon), are introduced by Langevin terms in the mapping equations

  10. Radiofrequency generation by coherently moving fluxons

    Science.gov (United States)

    Dobrovolskiy, O. V.; Sachser, R.; Huth, M.; Shklovskij, V. A.; Vovk, R. V.; Bevz, V. M.; Tsindlekht, M. I.

    2018-04-01

    A lattice of Abrikosov vortices in type II superconductors is characterized by a periodic modulation of the magnetic induction perpendicular to the applied magnetic field. For a coherent vortex motion under the action of a transport current, the magnetic induction at a given point of the sample varies in time with a washboard frequency fWB = v/d, where v is the vortex velocity and d is the distance between the vortices in the direction of motion. Here, by using a spectrum analyzer connected to a 50 nm-wide Au nanowire meander near the surface of a superconducting Nb film, we detect an ac voltage induced by coherently moving fluxons. The voltage is peaked at the washboard frequency, fWB, and its subharmonics, fTOF = fWB/5, determined by the antenna width. By sweeping the dc current value, we reveal that fWB can be tuned from 100 MHz to 1.5 GHz, thereby demonstrating that patterned normal metal/superconductor nanostructures can be used as dc-tunable generators operating in the radiofrequency range.

  11. Spin gymnastics with selective radiofrequency pulses

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, R.; Kupce, E. [Cambridge Univ. (United Kingdom)

    1994-12-31

    Although high resolution NMR spectra are normally excited with short intense radiofrequency pulses, there is an entire family of new experiments that can be performed with frequency-selective or ``soft`` pulses. Time-consuming two-dimensional spectroscopy may be reduced to a much shorter one-dimensional version with much finer digitization in the frequency domain. A large number of soft pulses can be combined to form a ``polychromatic pulse`` that has uniform excitation over the entire range of proton shifts except for a rejection notch at the water frequency. Polychromatic pulses can also be used to create antiphase magnetization in preparation for a coherence transfer or double-quantum experiment. An excitation profile can be designed in the form of a ``template`` that exactly matches the spectrum of a given chemical compound but has zero excitation elsewhere. This is achieved by using the information in the experimental free induction decay to construct a suitable array of soft pulses that has the required excitation pattern. In this manner, interpenetrating spectra can be separated into the spectra of the pure components, for example those of a and b glucose. Selective Hartmann-Hahn coherence transfer experiments employ similar soft pulse techniques. If several such transfers are concatenated, the method may be used as a test to see whether a group of protons is linked in an unbroken chain by scalar spin-spin interactions. (authors). 24 refs., 18 figs.

  12. Cutaneous remodeling and photorejuvenation using radiofrequency devices

    Directory of Open Access Journals (Sweden)

    Elsaie Mohamed

    2009-01-01

    Full Text Available Radio frequency (RF is electromagnetic radiation in the frequency range of 3-300GHz. The primary effects of RF energy on living tissue are considered to be thermal. The goal of the new devices based on these frequency ranges is to heat specific layers of the skin. The directed use of RF can induce dermal heating and cause collagen degeneration. Wound healing mechanisms promote the remodeling of collagen and wound contraction, which ultimately clinically enhances the appearance of mild to moderate skin laxity. Preliminary studies have reported efficacy in the treatment of laxity that involves the periorbital area and jowls. Because RF energy is not dependent on specific chromophore interaction, epidermal melanin is not at risk of destruction and treatment of all skin types is possible. As such, radiofrequency-based systems have been used successfully for nonablative skin rejuvenation, atrophic scar revision and treatment of unwanted hair, vascular lesions and inflammatory acne. The use of RF is becoming more popular, although a misunderstanding exists regarding the mechanisms and limitations of its actions. This concise review serves as an introduction and guide to many aspects of RF in the non ablative rejuvenation of skin.

  13. Radiofrequency Heating Pathways for Gold Nanoparticles

    Science.gov (United States)

    Collins, C. B.; McCoy, R. S.; Ackerson, B. J.; Collins, G. J.

    2015-01-01

    This feature article reviews the thermal dissipation of nanoscopic gold under radiofrequency (RF) irradiation. It also presents previously unpublished data addressing obscure aspects of this phenomenon. While applications in biology motivated initial investigation of RF heating of gold nanoparticles, recent controversy concerning whether thermal effects can be attributed to nanoscopic gold highlight the need to understand the involved mechanism or mechanisms of heating. Both the nature of the particle and the nature of the RF field influence heating. Aspects of nanoparticle chemistry and physics, including the hydrodynamic diameter of the particle, the oxidation state and related magnetism of the core, and the chemical nature of the ligand shell may all strongly influence to what extent a nanoparticle heats in an RF field. Aspects of RF include: power, frequency and antenna designs that emphasize relative strength of magnetic or electric fields, and also influence the extent to which a gold nanoparticle heats in RF. These nanoparticle and RF properties are analysed in the context of three heating mechanisms proposed to explain gold nanoparticle heating in an RF field. This article also makes a critical analysis of the existing literature in the context of the nanoparticle preparations, RF structure, and suggested mechanisms in previously reported experiments. PMID:24962620

  14. Radiofrequency ablation for renal tumors. Our experience

    International Nuclear Information System (INIS)

    Hiraoka, Kenji; Kawauchi, Akihiro; Nakamura, Terukazu; Soh, Jintetsu; Mikami, Kazuya; Miki, Tsuneharu

    2009-01-01

    The objective of this study was to report our results of percutaneous radiofrequency ablation (RFA) for renal tumors and to assess predictors of therapeutic efficacy. Forty patients (median age 73 years) with renal tumors were treated with RFA under local or epidural anesthesia. All of them had high surgical risk or refused radical surgery. Tumors were punctured percutaneously using the Radionics Cool-tip RF System under computed tomography or ultrasonographic guidance. Median tumor diameter was 24 mm. After RFA, contrast-enhanced computed tomography or magnetic resonance imaging was performed within 1 month. Complete response (CR) was defined as no enhancement inside the tumor. Factors related to the outcome and to renal function were assessed. Median follow up was 16 months. CR was observed in 34 cases (85.0%). A significant difference in CR rate was observed between tumors ≤30 mm and those >30 mm. Outcomes tended to be better for tumors in the mid to lower kidney, and those away from the renal hilum. Recurrence was observed in one case (2.9%), but a CR was obtained again by additional RFA. Out of a total of 77 RFA procedures, complications occurred in only three cases (3.9%), and conservative treatment was possible in all cases. Serum creatinine levels 3 months after RFA did not differ from those before RFA. Percutaneous RFA is a safe and effective treatment for small renal tumors in patients with high surgical risk or who refuse radical surgery. (author)

  15. Radio-frequency plasma spraying of ceramics

    International Nuclear Information System (INIS)

    Okada, T.; Hamatani, H.; Yoshida, T.

    1989-01-01

    This study was aimed at developing a novel spraying process using a radio-frequency (rf) plasma. Experiments of Al 2 O 3 and ZrO 2 - 8 wt% Y 2 O 3 spraying showed that the initial powder size was the most important parameter for depositing dense coatings. The optimum powder sizes of Al 2 O 3 and ZrO 2 - 8 wt% Y 2 O 3 were considered to be around 100 and 80 μm, respectively. The use of such large-size powders compared with those used by conventional dc plasma spraying made it possible to deposit adherent ceramics coatings of 150 to 300 μm on as-rolled SS304 substrates. It was also shown that low particle velocity of about 10 m/s, which is peculiar to rf plasma spraying, was sufficient for particle deformation, though it imposed a severe limitation on the substrate position. These experimental results prove that rf plasma spraying is an effective process and a strong candidate to open new fields of spraying applications

  16. Radiofrequency (RF) radiation measurement for diathermy machine

    International Nuclear Information System (INIS)

    Rozaimah Abdul Rahim; Roha Tukimin; Mohd Amirul Nizam; Ahmad Fadzli; Mohd Azizi

    2010-01-01

    Full-text: Diathermy machine is one of medical device that use widely in hospital and clinic. During the diathermy treatment, high radiofrequency (RF) currents (shortwave and microwave) are used to heat deep muscular tissues through electromagnetic energy to body tissues. The heat increases blood flow, relieve pain and speeding up recovery. The stray RF radiation from the machine can exposes to unintended tissue of the patient, to the operator (physical therapist) and also can cause electromagnetic interference (EMI) effect to medical devices around the machine. The main objective of this study is to establish a database of the RF radiation exposure levels experienced by the operator and patient during the treatments. RF radiation (electric and magnetic field) produced by the diathermy machines were measured using special RF survey meters. The finding of this study confirms that radiation levels on the surface and near the applicator of the diathermy machine much more elevated due to the much closer distance to the source and they exceeding the occupational and general public exposure limit. The results also shows the field strengths drop very significantly when the distance of measurement increase. (author)

  17. Radiofrequency facial rejuvenation: evidence-based effect.

    Science.gov (United States)

    el-Domyati, Moetaz; el-Ammawi, Tarek S; Medhat, Walid; Moawad, Osama; Brennan, Donna; Mahoney, My G; Uitto, Jouni

    2011-03-01

    Multiple therapies involving ablative and nonablative techniques have been developed for rejuvenation of photodamaged skin. Monopolar radiofrequency (RF) is emerging as a gentler, nonablative skin-tightening device that delivers uniform heat to the dermis at a controlled depth. We evaluated the clinical effects and objectively quantified the histologic changes of the nonablative RF device in the treatment of photoaging. Six individuals of Fitzpatrick skin type III to IV and Glogau class I to II wrinkles were subjected to 3 months of treatment (6 sessions at 2-week intervals). Standard photographs and skin biopsy specimens were obtained at baseline, and at 3 and 6 months after the start of treatment. We performed quantitative evaluation of total elastin, collagen types I and III, and newly synthesized collagen using computerized histometric and immunohistochemical techniques. Blinded photographs were independently scored for wrinkle improvement. RF produced noticeable clinical results, with high satisfaction and corresponding facial skin improvement. Compared with the baseline, there was a statistically significant increase in the mean of collagen types I and III, and newly synthesized collagen, while the mean of total elastin was significantly decreased, at the end of treatment and 3 months posttreatment. A limitation of this study is the small number of patients, yet the results show a significant improvement. Although the results may not be as impressive as those obtained by ablative treatments, RF is a promising treatment option for photoaging with fewer side effects and downtime. Copyright © 2010 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Characterization of tracked radiofrequency ablation in phantom

    International Nuclear Information System (INIS)

    Chen, Chun-Cheng R.; Miga, Michael I.; Galloway, Robert L.

    2007-01-01

    In radiofrequency ablation (RFA), successful therapy requires accurate, image-guided placement of the ablation device in a location selected by a predictive treatment plan. Current planning methods rely on geometric models of ablations that are not sensitive to underlying physical processes in RFA. Implementing plans based on computational models of RFA with image-guided techniques, however, has not been well characterized. To study the use of computational models of RFA in planning needle placement, this work compared ablations performed with an optically tracked RFA device with corresponding models of the ablations. The calibration of the tracked device allowed the positions of distal features of the device, particularly the tips of the needle electrodes, to be determined to within 1.4±0.6 mm of uncertainty. Ablations were then performed using the tracked device in a phantom system based on an agarose-albumin mixture. Images of the sliced phantom obtained from the ablation experiments were then compared with the predictions of a bioheat transfer model of RFA, which used the positional data of the tracked device obtained during ablation. The model was demonstrated to predict 90% of imaged pixels classified as being ablated. The discrepancies between model predictions and observations were analyzed and attributed to needle tracking inaccuracy as well as to uncertainties in model parameters. The results suggest the feasibility of using finite element modeling to plan ablations with predictable outcomes when implemented using tracked RFA

  19. Récupération de l'énergie micro-onde pour l'alimentation de capteurs sans fil à bord des satellites

    OpenAIRE

    Okba , Abderrahim; Takacs , Alexandru; Aubert , Hervé; Fredon , Stéphane; Despoisse , Laurent

    2015-01-01

    National audience; La récupération d'énergie micro-onde à bord des satellites de télécommunication géostationnaires est abordée dans cette communication. Plusieurs topologies de rectennas sont proposées. Certaines d'entre elles, très compactes, permettent de récupérer des puissances DC de l'ordre de 1 mW. Ces résultats montrent que la récupération d'énergie micro-onde représente une solution intéressante pour l'alimentation des capteurs autonomes sans fil utilisés pour le suivi de l'état de f...

  20. Systematic Review of Radiofrequency Ablation and Pulsed Radiofrequency for Management of Cervicogenic Headaches.

    Science.gov (United States)

    Grandhi, Ravi K; Kaye, Alan David; Abd-Elsayed, Alaa

    2018-02-23

    Cervicogenic headache (CHA) is a secondary headache which has a source in the upper cervical spine. Many traditional analgesic choices lack good efficacy in managing the associated pain. As a result, in management of CHA, radiofrequency ablation (RFA) or pulse radiofrequency (PRF) has been tried with success. Our study investigated the use of RFA and PRF for the management of CHA. In the present investigation, a review of the literature was conducted using PubMed (1966 to February 2017). The quality assessment was determined using The Cochrane Risk of Bias. After initial search and consultation with experts, 34 articles were identified for initial review and 10 articles met inclusion for review. Criteria for inclusion were primarily based on identification of articles discussing cervicogenic headaches which were previously treatment resistant and occurred without any other pathology of the craniofacial region or inciting event such as trauma. This systematic review demonstrated that RFA and PRFA provide very limited benefit in the management of CHA. At present, there is no high-quality RCT and/or strong non-RCTs to support the use of these techniques, despite numerous case reports which have demonstrated benefit. This review is one of the first to provide a comprehensive overview of the use of RFA and PRF in the management of CHA.

  1. Reduction of spectra exposed by the 700mm CCD camera of the Ondřejov telescope coudé spectrograph

    Science.gov (United States)

    Skoda, Petr; Slechta, Miroslav

    We present a brief cook-book for the reduction of spectra exposed by the Ondřejov 2-meter telescope coudé spectrograph. For the data reduction, we use standard IRAF packages running on Solaris and Linux. The sequence of commands is given for the typical reduction session together with short explanation and detailed list of parameter settings. The reduction progress is illustrated by example plots.

  2. Symplicity multi-electrode radiofrequency renal denervation system feasibility study.

    Science.gov (United States)

    Whitbourn, Robert; Harding, Scott A; Walton, Antony

    2015-05-01

    The aim of this study was to test the safety and performance of the Symplicity™ multi-electrode radio-frequency renal denervation system which was designed to reduce procedure time during renal denervation. The multi-electrode radiofrequency renal denervation system feasibility study is a prospective, non-randomised, open label, feasibility study that enrolled 50 subjects with hypertension. The study utilises a new renal denervation catheter which contains an array of four electrodes mounted in a helical configuration at 90 degrees from each other to deliver radiofrequency energy simultaneously to all four renal artery quadrants for 60 seconds. The protocol specified one renal denervation treatment towards the distal end of each main renal artery with radiofrequency energy delivered for 60 seconds per treatment. Total treatment time for both renal arteries was two minutes. The 12-month change in office systolic blood pressure (SBP) and 24-hour SBP was -19.2±25.2 mmHg, prenal artery stenosis or hypertensive emergencies occurred. The Symplicity multi-electrode radiofrequency renal denervation system was associated with a significant reduction in SBP at 12 months and minimal complications whilst it also reduced procedure time. NCT01699529.

  3. Radiofrequency for the treatment of skin laxity: mith or truth*

    Science.gov (United States)

    de Araújo, Angélica Rodrigues; Soares, Viviane Pinheiro Campos; da Silva, Fernanda Souza; Moreira, Tatiane da Silva

    2015-01-01

    The nonablative radiofrequency is a procedure commonly used for the treatment of skin laxity from an increase in tissue temperature. The goal is to induce thermal damage to thus stimulate neocollagenesis in deep layers of the skin and subcutaneous tissue. However, many of these devices haven't been tested and their parameters are still not accepted by the scientific community. Because of this, it is necessary to review the literature regarding the physiological effects and parameters for application of radiofrequency and methodological quality and level of evidence of studies. A literature search was performed in MEDLINE, PEDro, SciELO, PubMed, LILACS and CAPES and experimental studies in humans, which used radiofrequency devices as treatment for facial or body laxity, were selected. The results showed that the main physiological effect is to stimulate collagen synthesis. There was no homogeneity between studies in relation to most of the parameters used and the methodological quality of studies and level of evidence for using radiofrequency are low. This fact complicates the determination of effective parameters for clinical use of this device in the treatment of skin laxity. The analyzed studies suggest that radiofrequency is effective, however the physiological mechanisms and the required parameters are not clear in the literature. PMID:26560216

  4. Treatment of acne vulgaris with fractional radiofrequency microneedling.

    Science.gov (United States)

    Kim, Sang Tae; Lee, Kang Hoon; Sim, Hyung Jun; Suh, Kee Suck; Jang, Min Soo

    2014-07-01

    Fractional radiofrequency microneedling is a novel radiofrequency technique that uses insulated microneedles to deliver energy to the deep dermis at the point of penetration without destruction of the epidermis. It has been used for the treatment of various dermatological conditions including wrinkles, atrophic scars and hypertrophic scars. There have been few studies evaluating the efficacy of fractional radiofrequency microneedling in the treatment of acne, and none measuring objective parameters like the number of inflammatory and non-inflammatory acne lesions or sebum excretion levels. The safety and efficacy of fractional radiofrequency microneedling in the treatment of acne vulgaris was investigated. In a prospective clinical trial, 25 patients with moderate to severe acne were treated with fractional radiofrequency microneedling. The procedure was carried out three times at 1-month intervals. Acne lesion count, subjective satisfaction score, sebum excretion level and adverse effects were assessed at baseline and at 4, 8 and 12 weeks after the first treatment as well as 4, 8 and 12 weeks after the last treatment. Number of acne lesions (inflammatory and non-inflammatory) decreased. Sebum excretion and subjective satisfaction were more favorable at every time point compared with the baseline values (P acne vulgaris. © 2014 Japanese Dermatological Association.

  5. Radiofrequency ablation of liver tumors (II): clinical application and outcomes.

    Science.gov (United States)

    Vanagas, Tomas; Gulbinas, Antanas; Pundzius, Juozas; Barauskas, Giedrius

    2010-01-01

    Radiofrequency ablation is one of the alternatives in the management of liver tumors, especially in patients who are not candidates for surgery. The aim of this article is to review applicability of radiofrequency ablation achieving complete tumor destruction, utility of imaging techniques for patients' follow-up, indications for local ablative procedures, procedure-associated morbidity and mortality, and long-term results in patients with different tumors. The success of local thermal ablation consists in creating adequate volumes of tissue destruction with adequate "clear margin," depending on improved delivery of radiofrequency energy and modulated tissue biophysiology. Different volumes of coagulation necrosis are achieved applying different types of electrodes, pulsing energy sources, utilizing sophisticated ablation schemes. Some additional methods are used to increase the overall deposition of energy through alterations in tissue electrical conductivity, to improve heat retention within the tissue, and to modulate tolerance of tumor tissue to hyperthermia. Contrast-enhanced computed tomography, magnetic resonance imaging, ultrasound or positron emission tomography are applied to control the effectiveness of radiofrequency ablation. The long-term results of radiofrequency ablation are controversial.

  6. Visualizing radiofrequency-skin interaction using multiphoton microscopy in vivo.

    Science.gov (United States)

    Tsai, Tsung-Hua; Lin, Sung-Jan; Lee, Woan-Ruoh; Wang, Chun-Chin; Hsu, Chih-Ting; Chu, Thomas; Dong, Chen-Yuan

    2012-02-01

    Redundant skin laxity is a major feature of aging. Recently, radiofrequency has been introduced for nonablative tissue tightening by volumetric heating of the deep dermis. Despite the wide range of application based on this therapy, the effect of this technique on tissue and the subsequent tissue remodeling have not been investigated in detail. Our objective is to evaluate the potential of non-linear optics, including multiphoton autofluorescence and second harmonic generation (SHG) microscopy, as a non-invasive imaging modality for the real-time study of radiofrequency-tissue interaction. Electro-optical synergy device (ELOS) was used as the radiofrequency source in this study. The back skin of nude mouse was irradiated with radiofrequency at different passes. We evaluated the effect on skin immediately and 1 month after treatment with multiphoton microscopy. Corresponding histology was performed for comparison. We found that SHG is negatively correlated to radiofrequency passes, which means that collagen structural disruption happens immediately after thermal damage. After 1 month of collagen remodeling, SHG signals increased above baseline, indicating that collagen regeneration has occurred. Our findings may explain mechanism of nonablative skin tightening and were supported by histological examinations. Our work showed that monitoring the dermal heating status of RF and following up the detailed process of tissue reaction can be imaged and quantified with multiphoton microscopy non-invasively in vivo. Copyright © 2011. Published by Elsevier Ireland Ltd.

  7. 21 CFR 870.2910 - Radiofrequency physiological signal transmitter and receiver.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency physiological signal transmitter... Devices § 870.2910 Radiofrequency physiological signal transmitter and receiver. (a) Identification. A radiofrequency physiological signal transmitter and receiver is a device used to condition a physiological signal...

  8. 21 CFR 179.30 - Radiofrequency radiation for the heating of food, including microwave frequencies.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Radiofrequency radiation for the heating of food... PRODUCTION, PROCESSING AND HANDLING OF FOOD Radiation and Radiation Sources § 179.30 Radiofrequency radiation for the heating of food, including microwave frequencies. Radiofrequency radiation, including...

  9. Radiofrequency ablation of osteoid osteomas: five years experience.

    Science.gov (United States)

    Papathanassiou, Zafiria G; Petsas, Theodore; Papachristou, Dionysios; Megas, Panagiotis

    2011-12-01

    The purpose of this study is to retrospectively evaluate the efficacy of radiofrequency ablation as a curative treatment method for benign bone tumours. Twenty-nine osteoid osteomas were treated with radiofrequency ablation. Primary success rate was 89.6% and total secondary success rate was 93.1%. Mean clinical follow-up period was 26.7 months (range: 6-63 months). Statistical analysis of 25 cases of osteoid osteomas with CT follow-up revealed that post-treatment re-ossification does not correlate with clinical outcome (p = 0.14) but is strongly correlated with long-term (> or = 12 months) CT follow-up (p = 0.014). Percutaneous radiofrequency ablation was found to be an effective and safe treatment for osteoid osteomas. CT findings cannot solely differentiate between treatment successes and failures.

  10. Influence of radiofrequency surgery on architecture of the palatine tonsils.

    Science.gov (United States)

    Plzak, Jan; Macokova, Pavla; Zabrodsky, Michal; Kastner, Jan; Lastuvka, Petr; Astl, Jaromir

    2014-01-01

    Radiofrequency surgery is a widely used modern technique for submucosal volume reduction of the tonsils. So far there is very limited information on morphologic changes in the human tonsils after radiofrequency surgery. We performed histopathological study of tonsillectomy specimens after previous bipolar radiofrequency induced thermotherapy (RFITT). A total of 83 patients underwent bipolar RFITT for hypertrophy of palatine tonsils. Tonsil volume reduction was measured by 3D ultrasonography. Five patients subsequently underwent tonsillectomy. Profound histopathological examination was performed to determine the effect of RFITT on tonsillar architecture. All tonsillectomy specimens showed the intact epithelium, intact germinal centers, normal vascularization, and no evidence of increased fibrosis. No microscopic morphological changes in tonsillectomy specimens after bipolar RFITT were observed. RFITT is an effective submucosal volume reduction procedure for treatment of hypertrophic palatine tonsils with no destructive effect on microscopic tonsillar architecture and hence most probably no functional adverse effect.

  11. Percutaneous radiofrequency ablation for benign nodules of the thyroid gland

    International Nuclear Information System (INIS)

    Baek, Jung Hwan; Jeong, Hyun Jo; Kim, Yoon Suk; Kwak, Min Sook; Chang, Sun Hee; Rhim, Hyun Chul

    2005-01-01

    We wanted to evaluate the efficacy and safety of using ultrasound guided percutaneous radiofrequency ablation for the benign nodules of the thyroid gland. We studied 148 patients with benign thyroid nodules (200 total nodules) that were confirmed histopathologically, and we performed ultrasound guided radiofrequency ablation. The radiofrequency ablation was done 1 to 5 times per one nodule, and follow-up ultrasonography was performed one to nineteen months after the ablation procedures. The physical changes and the decrease of volume of the nodules were evaluated, and the complications related to radiofrequency ablation were observed. The mean initial nodule volume was 0.01-95.61 ml (mean; 6.83 ± SD of 10.63 ml) and the nodule volume after radiofrequency ablation was decreased to 0.00-46.56 ml (mean; 1.83 ± SD of 4.69 ml). The mean volume reduction rate was 73.2%. Reduction of more than 50% was noted in 90% of all cases. For 180 nodules (90%), the decrease was 50% or more, in 20 nodules (10%), the decrease was 49% or less. On gray-scale ultrasonogram obtained after ablation, the echogenicity of the nodules changed to darker, and on the doppler-sonogram, the vascular flow within the nodules disappeared in all cases. Most patients complained pain during or right after the procedure, but the pain was transient and subsided after medication. Two patients developed hoarseness that was improved in 1 week and 2 months, respectively. Sonoguided percutaneous radiofrequency ablation can be one of the treatments for benign nodules of the thyroid gland

  12. Propagation des ondes acoustiques dans les milieux poreux saturés Propagation of Acoustic Waves in Saturated Porous Media

    Directory of Open Access Journals (Sweden)

    Coussy O.

    2006-11-01

    Full Text Available Ce travail comporte deux parties. La première partie concerne la théorie de la propagation des ondes acoustiques dans les milieux poreux saturés. Une revue des différentes méthodes existantes est faite et un développement critique de la théorie de Biot est exposé en détail. On examine en particulier les différents résultats auxquels cette théorie conduit et on regarde, dans quelles conditions et sur quels problèmes géophysiques, les phénomènes physiques mis en évidence peuvent jouer de manière notable. Dans la deuxième partie, on présente une vérification expérimentale due à Plona (1980 de la théorie de Biot. Après une introduction qualitative de l'expérience mise en place, on expose les résultats obtenus pour un grand nombre de matériaux de porosités différentes. La notion de tortuosité d'un milieu poreux est introduite théoriquement et discutée expérimentalement. This article is in two parts. The first part has to do with the theory of acoustic wave propagation in saturated porous media. Different existing methods are reviewed, and Biot's theory is critically developed in detail. In particular, the different results to which this theory leads are examined, and the conditions and geophysical problems on which the physical phenomena involved may have an appreciable effect are considered. The second part is devoted to the experimental check made by Plona (1980 of Biot's theory. After a qualitative introduction of the experimental procedure, the results obtained for many materials of different porosities are described. The concept of the tortuosity of a porous medium is introduced theoretically and discussed experimentally.

  13. Shock wave air dissociation and ionization; Dissociation et ionisation de l'air par une onde de choc

    Energy Technology Data Exchange (ETDEWEB)

    Thouvenin, J. [Commissariat a l' energie atomique et aux energies alternatives - CEA (France)

    1959-07-01

    The composition and internal energy of air are computed for a range of temperature from 3 500 up to 11500 deg. K and a range of density from 4 up to 12 times normal density. In another connection, the increase of internal energy of air by a shock wave traveling through it is evaluated in terms of the same parameters. By adjusting both expressions of energy, a relation between the temperature T and the ratio of molecular volumes V{sub 0}/V ahead and behind the shock front is obtained. The others physical variables, pressure, front velocity, material velocity, degree of ionization, can be then computed if either of parameters T or V{sub 0}/V is known. Conversely, measurement of any one physical variable makes it possible to get values of all the others. Present calculations show the oxygen to be completely dissociated by strong shock waves (velocities above 7000 m/s), the nitrogen by a rate of 50 % higher, and the concentration of free electrons to be over 0,1 %. Reprint of a paper published in 'Le journal de physique et le radium', Tome 19, July 1958, p. 639-648 [French] La composition de l'air et la valeur de son energie interne sont calculees pour des temperatures allant de 3 500 a 11 500 deg. K et des densites de 4 a 12 fois superieures a la densite normale. D'autre part, on determine, en fonction des memes parametres, l'augmentation d'energie interne de l'air due au passage d'une onde de choc. En egalant les deux expressions de l'energie, on obtient une relation entre la temperature T et le rapport des volumes moleculaires V{sub 0}/ V devant et derriere le front de choc. Les valeurs des autres grandeurs physiques, pression, vitesse du front, vitesse d'ecoulement, taux d'ionisation dans le front, sont alors determinees si l'on connait l'un des parametres T ou V{sub 0}/ V. Inversement, la mesure de l'une quelconque de ces grandeurs physiques permet de fixer la valeur de toutes les autres. Le calcul montre que pour des chocs intenses (vitesses superieures a 7000 m

  14. Cooling system for the IFMIF-EVEDA radiofrequency system

    International Nuclear Information System (INIS)

    Perez Pichel, G. D.

    2012-01-01

    The IFMIF-EVEDA project consists on an accelerator prototype that will be installed at Rokkasho (Japan). Through CIEMAT, that is responsible of the development of many systems and components. Empresarios Agrupados get the responsibility of the detailed design of the cooling system for the radiofrequency system (RF system) that must feed the accelerator. the RF water cooling systems is the water primary circuit that provides the required water flow (with a certain temperature, pressure and water quality) and also dissipates the necessary thermal power of all the radiofrequency system equipment. (Author) 4 refs.

  15. A New Radiofrequency Ablation Procedure to Treat Sacroiliac Joint Pain.

    Science.gov (United States)

    Cheng, Jianguo; Chen, See Loong; Zimmerman, Nicole; Dalton, Jarrod E; LaSalle, Garret; Rosenquist, Richard

    2016-01-01

    Low back pain may arise from disorders of the sacroiliac joint in up to 30% of patients. Radiofrequency ablation (RFA) of the nerves innervating the sacroiliac joint has been shown to be a safe and efficacious strategy. We aimed to develop a new RFA technique to relieve low back pain secondary to sacroiliac joint disorders. Methodology development with validation through prospective observational non-randomized trial (PONRT). Academic multidisciplinary health care system, Ohio, USA. We devised a guide-block to facilitate accurate placement of multiple electrodes to simultaneously ablate the L5 dorsal ramus and lateral branches of the S1, S2, and S3 dorsal rami. This was achieved by bipolar radiofrequency ablation (b-RFA) to create a strip lesion from the lateral border of the base of the sacral superior articular process (L5-S1 facet joint) to the lateral border of the S3 sacral foramen. We applied this technique in 31 consecutive patients and compared the operating time, x-ray exposure time and dose, and clinical outcomes with patients (n = 62) who have been treated with the cooled radiofrequency technique. Patients' level of pain relief was reported as 80% pain relief at one, 3, 6, and 12 months after the procedure. The relationship between RFA technique and duration of pain relief was evaluated using interval-censored multivariable Cox regression. The new technique allowed reduction of operating time by more than 50%, x-ray exposure time and dose by more than 80%, and cost by more than $1,000 per case. The percent of patients who achieved > 50% pain reduction was significantly higher in the b-RFA group at 3, 6, and 12 months follow-up, compared to the cooled radiofrequency group. No complications were observed in either group. Although the major confounding factors were taken into account in the analysis, use of historical controls does not balance observed and unobserved potential confounding variables between groups so that the reported results are potentially

  16. Thermal Protection with 5% Dextrose Solution Blanket During Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Chen, Enn Alexandria; Neeman, Ziv; Lee, Fred T.; Kam, Anthony; Wood, Brad

    2006-01-01

    A serious complication for any thermal radiofrequency ablation is thermal injury to adjacent structures, particularly the bowel, which can result in additional major surgery or death. Several methods using air, gas, fluid, or thermometry to protect adjacent structures from thermal injury have been reported. In the cases presented in this report, 5% dextrose water (D5W) was instilled to prevent injury to the bowel and diaphragm during radiofrequency ablation. Creating an Insulating envelope or moving organs with D5W might reduce risk for complications such as bowel perforation

  17. Radiofrequency/infrared double resonance spectroscopy of the HD+ ion

    International Nuclear Information System (INIS)

    Carrington, Alan; McNab, I.R.; Montgomerie, C.A.

    1989-01-01

    We describe a double resonance technique for obtaining radiofrequency spectra of the HD + ion in vibration-rotation levels close to the dissociation limit. Infrared transitions are driven by Doppler tuning an HD + ion beam into resonance with a carbon dioxide infrared laser, and are detected by measuring H + fragment ions produced by electric field dissociation of the upper vibration-rotation level. Radiofrequency transitions between nuclear hyperfine components of the lower vibration-rotation level are then detected through resonant increases in the H + fragment ion current. The high spectroscopic resolution obtained, and the ability to measure magnetic dipole hyperfine transitions, will enable the hyperfine constants to be determined accurately. (author)

  18. Exposure of Ontario workers to radiofrequency fields from dielectric heaters

    International Nuclear Information System (INIS)

    Bitran, M.E.; Nishio, J.M.; Charron, D.E.

    1992-01-01

    As part of a program to assess and reduce the exposure of Ontario workers to non-ionizing radiations, stray electric and magnetic fields from 383 dielectric heaters were measured in 71 industrial establishments from 1988 to 1990. This represents a population of over 800 workers potentially exposed to radiofrequency (RE) electromagnetic fields. Electric and magnetic field strengths at the head, waist, and thigh levels of the operators, corrected by duty cycle, are presented for the different heater types surveyed. Worker exposure data and compliance with Ontario radiofrequency exposure guidelines are discussed. (author)

  19. Radiofrequency Ablation Effectively Treated Focal Recurrence of Mesothelioma.

    Science.gov (United States)

    Nakamura, Akifumi; Takuwa, Teruhisa; Hashimoto, Masaki; Kondo, Nobuyuki; Takaki, Haruyuki; Fujiwara, Masayuki; Yamakado, Koichiro; Hasegawa, Seiki

    2018-02-01

    A 55-year-old man with malignant pleural mesothelioma underwent multimodality treatment comprising induction chemotherapy followed by extrapleural pneumonectomy and radiation therapy. After 2.5 years, focal recurrence occurred, with computed tomography revealing a tumor in the left cardiophrenic angle. Surgery was considered a problem for the patient because of the previous extrapleural pneumonectomy and difficult tumor location. Radiofrequency ablation was thus performed; the course was uneventful, and there was no recurrence. Radiofrequency ablation should be considered an option to treat recurrence of malignant pleural mesothelioma. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Endoscopic ultrasound-guided radiofrequency ablation of the pancreas

    DEFF Research Database (Denmark)

    Silviu, Ungureanu Bogdan; Daniel, Pirici; Claudiu, Mărgăritescu

    2015-01-01

    ultrasound (EUS)-guided radiofrequency ablation (RFA) probe through a 19G needle in order to achieve a desirable necrosis area in the pancreas. Radiofrequency ablation of the head of the pancreas was performed on 10 Yorkshire pigs with a weight between 25 kg and 35 kg and a length of 40-70 cm. Using an EUS...... analysis revealed increased values of amylase, alkaline phosphatase, and gamma-glutamyl transpeptidase on the 3rd day but a decrease on the 5th day. After necropsy and isolation of the pancreas, the ablated area was easily found, describing a solid necrosis. The pathological examination revealed...

  1. Standard guidelines for electrosurgery with radiofrequency current

    Directory of Open Access Journals (Sweden)

    Mutalik Sharad

    2009-08-01

    Full Text Available Definition: Radiofrequency (RF induces thermal destruction of the targeted tissue by an electrical current at a frequency of 0.5 MHz (RF. As the electrode tip is not heated, there is minimal thermal damage to the surrounding tissues, producing good esthetic results. Therefore, RF ablation is also known as cold ablation or "coblation." Modality: It has three modes of operation: (a Cut, (b cut and coagulate and (c coagulate. Therefore, it can be used for various purposes like incision, ablation, fulguration, shave excision and coagulation. Because of the coagulation facility, hemostasis can be achieved and operation becomes easier and faster. Indications: It is effective in treating various skin conditions like dermatosis papulosa nigra, warts, molluscum contagiosum, colloid milia, acquired junctional, compound and dermal melanocytic nevi, seborrheic keratosis, skin tags, granuloma pyogenicum, verrucous epidermal nevi, xanthelesma, rhinophyma, superficial basal cell carcinoma and telangiectasia. It can also be used for cosmetic indications such as resurfacing, earlobe repair and blepharoplasty. Anesthesia: The procedure is accomplished either under topical anesthesia eutactic mixture of local anesthetics or local injectable anesthesia, under all aseptic precautions. Procedure: While operating, only the tip of the electrode should come in contact with the tissue. Actual contact of the electrode with the tissue should be very brief in order to prevent excessive damage to the deeper tissues. This can be accomplished by moving the electrode quickly. Complications: Complications are uncommon and mainly occur due to an improper technique. The treating physician should be aware of the contraindications of the procedure as listed in these guidelines. Physician qualification: RF surgery may be performed by a dermatologist who has acquired adequate training during post-graduation or through recognized fellowships and workshops dedicated to RF surgery. He

  2. Ion source with radiofrequency mass filter for sputtering purposes

    International Nuclear Information System (INIS)

    Sielanko, J.; Sowa, M.

    1990-01-01

    The Kaufman ion source with radiofrequency mass filter is described. The construction as well as operating characteristics of ion source are presented. The arrangement is suitable for range distribution measurements of implanted layers, where the sputtering rate has to be constant over the wide range of sputtering time. 4 figs., 17 refs. (author)

  3. Mitral valve perforation appearing years after radiofrequency ablation

    DEFF Research Database (Denmark)

    Fisch-Thomsen, Marie; Jensen, Jesper K; Egeblad, Henrik

    2011-01-01

    The case is reported of a young adult with Wolff-Parkinson-White (WPW) syndrome who, three years after a complicated radiofrequency (RF) catheter ablation procedure, developed dyspnea on exertion. Echocardiography revealed severe mitral valve regurgitation caused by a perforation of the posterior...

  4. Temperature-controlled radiofrequency ablation of cardiac tissue

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1999-01-01

    BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequ......BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available...... for the frequently used temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size. METHODS AND RESULTS: In vitro strips......-controlled radiofrequency ablation increased external cooling of the electrode tip due to either flow of the surrounding liquid or poor electrode tissue contact, as exemplified by perpendicular versus parallel electrode orientation, increases lesion size significantly. This is in contrast to the impact of these factors...

  5. Noninvasive in vivo oximetric imaging by radiofrequency FT EPR

    NARCIS (Netherlands)

    Subramanian, S; Yamada, K; Irie, A; Murugesan, R; Cook, JA; Devasahayam, N; Van Dam, GM; Mitchell, JB; Krishna, MC

    A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed

  6. Radio-frequency energy in fusion power generation

    International Nuclear Information System (INIS)

    Lawson, J.Q.; Becraft, W.R.; Hoffman, D.J.

    1983-01-01

    The history of radio-frequency (rf) energy in fusion experiments is reviewed, and the status of current efforts is described. Potential applications to tasks other than plasma heating are described, as are the research and development needs of rf energy technology

  7. Radiofrequency solutions in clinical high field magnetic resonance

    NARCIS (Netherlands)

    Andreychenko, A.

    2013-01-01

    Magnetic resonance imaging (MRI) and spectroscopy (MRS) benefit from the sensitivity gain at high field (≥7T). However, high field brings also certain challenges associated with growing frequency and spectral dispersion. Frequency growth results in degraded performance of large volume radiofrequency

  8. Spectroscopic photoacoustic imaging of radiofrequency ablation in the left atrium

    NARCIS (Netherlands)

    S. Iskander-Rizk (Sophinese); P. Kruizinga (Pieter); A.F.W. van der Steen (Ton); G. van Soest (Gijs)

    2018-01-01

    textabstractCatheter-based radiofrequency ablation for atrial fibrillation has long-term success in 60-70% of cases. A better assessment of lesion quality, depth, and continuity could improve the procedure’s outcome. We investigate here photoacoustic contrast between ablated and healthy atrial-wall

  9. Theoretical resolving power of a radiofrequency mass spectrometer

    International Nuclear Information System (INIS)

    Coc, A.; Le Gac, R.; Saint Simon, M. de; Thibault, C.; Touchard, F.

    1988-01-01

    Radiofrequency mass spectrometers of L.G. Smith's type can reach a resolving power of 10 6 -10 7 and a precision of 10 -9 -10 -10 . The resolving power, shape of peaks and limitations are described. As an example, the spectrometer to be used in an experiment aimed at measuring the anti p/p mass ratio is considered. (orig.)

  10. Radiofrequency fields in our surroundings; Radiofrekvente felt i vaare omgivelser

    Energy Technology Data Exchange (ETDEWEB)

    2011-07-01

    In 2010, the National Radiation Protection Authority (NRPA) with the Post and Telecommunications Authority carried out a project where it is measured radiofrequency fields from various telecom systems in homes, kindergartens, schools, offices, and urban environments. Close to 99 percent of the measurement points were found values of less than one thousandth of the maximum. No values were near the limits. (AG)

  11. Health Impacts Of Radiofrequency Exposure From Mobile Phone ...

    African Journals Online (AJOL)

    Background: The widespread use of mobile phones and indiscriminate siting of transmitter base stations near residential buildings in our environment may have serious health impacts. Objective: To investigate the possible health risks associated with radiofrequency (RF) exposure from mobile phones and other transmitter ...

  12. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on ...

    African Journals Online (AJOL)

    Summary: Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed near the heart may interfere with the electrical rhythm of the heart or affect the blood pressure. Following informed consent, eighteen randomly selected apparently healthy male volunteers ...

  13. Bray–Liebhafsky oscillatory reaction in the radiofrequency electromagnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Stanisavljev, Dragomir R., E-mail: dragisa@ffh.bg.ac.rs [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia); Velikić, Zoran [Institute of Physics, University of Belgrade, Pregrevica 118, Zemun (Serbia); Veselinović, Dragan S.; Jacić, Nevena V.; Milenković, Maja C. [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia)

    2014-09-30

    Highlights: • Oscillatory Bray–Liebhafsky reaction is coupled with the radiofrequency radiation. • The effects of radiofrequency field on oscillatory parameters are investigated. • Radiofrequency power of up to the 0.2 W did not produced observable changes. • The explanation related with dissipative and capacitive effects is given. • Open the possibility of investigations of reactive effects on biological systems. - Abstract: Oscillatory Bray–Liebhafsky (BL) reaction is capacitively coupled with the electromagnetic radiation in the frequency range 60–110 MHz. Because of the specific reaction dynamics characterized by several characteristic parameters (induction period, period between chemical oscillations and their amplitude) it served as a good model system for the investigation of the effects of radiofrequent (RF) radiation. RF power of up to 0.2 W did not produce observable changes of the BL reaction parameters in the limit of the experiment reproductivity. Results indicate that, under the given experimental conditions, both dissipative and reactive properties of the solution are not considerably coupled with the RF electrical field.

  14. Skin tightening with a combined unipolar and bipolar radiofrequency device.

    Science.gov (United States)

    Mayoral, Flor A

    2007-02-01

    Monopolar radiofrequency (RF) devices are well established treatment modalities for tightening facial skin. A 60-year-old woman presented with a desire to tighten the lax skin and improve the appearance of both upper arms. A combination unipolar and bipolar RF device may provide volume reduction as well as skin tightening in the upper arm.

  15. Scattering of electromagnetic waves by an non-uniform cylindrical plasma; Diffusion coherente d'une onde electromagnetique par un cylindre de plasma inhomogene

    Energy Technology Data Exchange (ETDEWEB)

    Faugeras, P E [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires. Groupe de recherches sur la fusion controlee

    1967-07-01

    The problem of the scattering of plane electromagnetic waves from a non-uniform, cylindrically symmetrical plasma is solved analytically, by a self-consistent field method, for a wave with the electric field parallel to the cylinder axis. Numerical results for the diffracted field are plotted for interesting ranges of the parameters involved: diameter, density on the axis, radial profile of the density, and collision frequencies. The case where the incident field is cylindric (waves surfaces parallel to the cylinder axis) is examined - this permits to connect theoretical calculations and experimental diffraction patterns, and also to explain the diffraction effects observed in a classical microwave interferometry experiment. These results, and the possibility of measuring exactly the diffracted field (showed by experiments with dielectric and metallic rods) lead to a new plasma diagnostic method, based on the diffraction, which has no theoretical limitations and it usable when the classical free-space wave methods are not (plasma diameter lower than 10 wave lengths). The feasibility of this method is tested with a plasma at atmospheric pressure and a 2 mm incident wavelength. The plasma is obtained by the laminar flow of a plasma torch, with a working gas (He or Ar) seeded by potassium (density continuously variable between 10{sup 11} and 10{sup 15} e/cm{sup 3}. Some diffraction patterns by this plasma and for various incident waves, are also given and explained with theoretical calculations. (author) [French] On etudie la diffusion coherente d'une onde electromagnetique par un cylindre de plasma inhomogene par une methode de champ self-consistant, et pour une onde de vecteur electrique parallele a l'axe du cylindre. On a calcule le champ diffracte en faisant varier le diametre du cylindre, la densite sur l'axe, le profil de densite et les frequences de collisions, et on donne ici les principaux resultats. On examine ensuite le cas d'une onde incidente cylindrique

  16. Endovascular Radiofrequency Ablation for Varicose Veins

    Science.gov (United States)

    2011-01-01

    Executive Summary Objective The objective of the MAS evidence review was to conduct a systematic review of the available evidence on the safety, effectiveness, durability and cost–effectiveness of endovascular radiofrequency ablation (RFA) for the treatment of primary symptomatic varicose veins. Background The Ontario Health Technology Advisory Committee (OHTAC) met on August 26th, 2010 to review the safety, effectiveness, durability, and cost-effectiveness of RFA for the treatment of primary symptomatic varicose veins based on an evidence-based review by the Medical Advisory Secretariat (MAS). Clinical Condition Varicose veins (VV) are tortuous, twisted, or elongated veins. This can be due to existing (inherited) valve dysfunction or decreased vein elasticity (primary venous reflux) or valve damage from prior thrombotic events (secondary venous reflux). The end result is pooling of blood in the veins, increased venous pressure and subsequent vein enlargement. As a result of high venous pressure, branch vessels balloon out leading to varicosities (varicose veins). Symptoms typically affect the lower extremities and include (but are not limited to): aching, swelling, throbbing, night cramps, restless legs, leg fatigue, itching and burning. Left untreated, venous reflux tends to be progressive, often leading to chronic venous insufficiency (CVI). A number of complications are associated with untreated venous reflux: including superficial thrombophlebitis as well as variceal rupture and haemorrhage. CVI often results in chronic skin changes referred to as stasis dermatitis. Stasis dermatitis is comprised of a spectrum of cutaneous abnormalities including edema, hyperpigmentation, eczema, lipodermatosclerosis and stasis ulceration. Ulceration represents the disease end point for severe CVI. CVI is associated with a reduced quality of life particularly in relation to pain, physical function and mobility. In severe cases, VV with ulcers, QOL has been rated to be as bad

  17. Frittage micro-ondes en cavité monomode de biocéramiques Microwaves sintering of bioceramics in a single mode cavity

    Directory of Open Access Journals (Sweden)

    Savary Etienne

    2013-11-01

    Full Text Available Le but premier de cette étude est de montrer la faisabilité du frittage direct en cavité micro-ondes monomode de deux biomatériaux céramiques : l'hydroxyapatite et le phosphate tri-calcique. Ainsi, cette étude montre que ce procédé a permis d'obtenir, en des temps très courts, inférieurs à 20 minutes, des échantillons denses présentant des microstructures fines. Les caractérisations mécaniques sur les échantillons frittés par micro-ondes ont révélé des valeurs de module d'élasticité et de dureté supérieures à celles généralement obtenues sur des échantillons frittés de manière conventionnelle. Ces résultats sont discutés en fonction de la microstructure obtenue et des différents paramètres expérimentaux : granulométrie des poudres, température de frittage, temps d'irradiation micro-ondes. The main purpose of this study consists in investigating the direct microwaves sintering in a single mode cavity of two bioceramics: hydroxyapatite and tri-calcium phosphate. Thus, dense samples presenting fine microstructures are successfully obtained in less than 20 minutes of irradiation. The resulting mechanical characterizations on microwaves sintered samples evidence higher Young's modulus and hardness values than those usually reported on conventionally sintered samples. Those results are discussed according to the microstructures observed and the experimental parameters such as powders granulometries, sintering temperatures, microwaves irradiation times.

  18. Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.

    Science.gov (United States)

    Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H

    2016-05-01

    Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.

  19. The interaction of circularly polarised electromagnetic waves with a plasma; Interaction d'ondes electromagnetiques a polarisation circulaire avec un plasma

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T; Legardeur, R; Slama, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The interaction of left and right handed circularly polarised waves with a plasma are studied. The individual trajectories of charges of both signs are traced with a analogical simulator. Applications to plasma heating and diagnostic are deduced. (author) [French] On etudie l'interaction des ondes a polarisation circulaire droite ou gauche avec un plasma. Les trajectoires individuelles des charges sont tracees a l'aide d'un dispositif analogique. On en deduit les applications au chauffage d'un plasma et a la mesure de ses parametres caracteristiques. (auteur)

  20. Pulse-dose radiofrequency treatment in pain management-initial experience.

    Science.gov (United States)

    Ojango, Christine; Raguso, Mario; Fiori, Roberto; Masala, Salvatore

    2018-05-01

    Radiofrequency procedures have been used for treating various chronic pain conditions for decades. These minimally invasive percutaneous treatments employ an alternating electrical current with oscillating radiofrequency wavelengths to eliminate or alter pain signals from the targeted site. The aim of the continuous radiofrequency procedure is to increase the temperature sufficiently to create an irreversible thermal lesion on nerve fibres and thus permanently interrupt pain signals. The pulsed radiofrequency procedure utilises short pulses of radiofrequency current with intervals of longer pauses to avert a temperature increase to the level of permanent tissue damage. The goal of these pulses is to alter the processing of pain signals, but to avoid relevant structural damage to nerve fibres, as seen in the continuous radiofrequency procedure. The pulse-dose radiofrequency procedure is a technical improvement of the pulsed radiofrequency technique in which the delivery mode of the current is adapted. During the pulse-dose radiofrequency procedure thermal damage is avoided. In addition, the amplitude and width of the consecutive pulses are kept the same. The method ensures that each delivered pulse keeps the same characteristics and therefore the dose is similar between patients. The current review outlines the pulse-dose radiofrequency procedure and presents our institution's chronic pain management studies.

  1. Comparison of renal artery, soft tissue, and nerve damage after irrigated versus nonirrigated radiofrequency ablation.

    Science.gov (United States)

    Sakakura, Kenichi; Ladich, Elena; Fuimaono, Kristine; Grunewald, Debby; O'Fallon, Patrick; Spognardi, Anna-Maria; Markham, Peter; Otsuka, Fumiyuki; Yahagi, Kazuyuki; Shen, Kai; Kolodgie, Frank D; Joner, Michael; Virmani, Renu

    2015-01-01

    The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (Pradiofrequency group (Pradiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (Pradiofrequency ablation, and there is a trend toward less nerve damage. © 2014 American Heart Association, Inc.

  2. Radiofrequency hyperthermia for advanced malignant liver tumors

    International Nuclear Information System (INIS)

    Nagata, Y.; Okuno, Y.; Mitsumori, M.; Akuta, K.; Nishimura, Y.; Masunaga, S.; Kanamori, S.; Fujishiro, M.; Hiraoka, M.; Takahashi, M.; Abe, M.

    1996-01-01

    Purpose: To evaluate thermometry and the clinical results of radiofrequency (RF) thermotherapy for advanced malignant liver tumors. Materials and Methods One-hundred and seventy-three patients with malignant liver tumors treated between 1983 and 1995 underwent hyperthermia. Surgery were contraindicated in all patients. The 173 tumors consisted of 114 hepatocellular carcinomas(HCCs), and 59 non-HCCs(45 metastatic liver tumors and 12 cholangiocarcinomas). Eight MHz RF capacitive heating equipment was used for hyperthermia. Two opposing 25-cm or 30-cm electrodes were generally used for heating liver tumors. Our standard protocol was to administer hyperthermia 40-50 minutes twice a week to a total of 8 sessions. Temperature of the liver tumor was measured by microthermocouples. In each patient, a single catheter was inserted into the liver tumor through the normal liver. Transcatheter arterial embolization, radiotherapy, immunotherapy, and chemotherapy were combined with hyperthermia depending on the patient's liver function and tumor location. The therapeutic efficacy was evaluated by the change in tumor size assessed by computed tomography (CT) three or four months after the completion of treatment. Results One-hundred and forty (81%) of 173 patients underwent hyperthermia more than 4 times. Thermometry could be performed in 77(55%) of these 140 patients. Neither systolic nor diastolic blood pressure changed significantly after hyperthermia. However, pulse rate significantly increased from 82.8 ± 1.1 to 96.5 ± 1.3 beats/min. Only 21 patients (11%) showed a decrease in pulse rate after hyperthermia. Body temperature increased from 36.3 ±0.1 to 37.4±0.2 after hyperthermia. Sequelae of hyperthermia included focal fat burning in 20 (12%), gastric ulceration in 4 (2%), and liver necrosis in 1(1%). Sequelae of thermometry were severe peritoneal pain in 7 (11%), intraperitoneal hematoma in 1(1%), and pneumothorax in one (1%) patient. The maximal tumor temperature

  3. The transmission factor of a bloch wall for spin waves whose wave vector is perpendicular to the wall (1961); Facteur de transmission d'une paroi de bloch pour des ondes de spin de vecteur d'onde normal a la paroi (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Boutron, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    When, for a ferromagnetic, the anisotropic energy takes the form E= K sin{sup 2} {alpha}, the study of the propagation of spin waves of low energy across a Bloch wall leads to a one-dimensional Schrodinger equation in which is found a potential well which has the remarkable property of being completely transparent for all values of the incident wave energy. (author) [French] Dans un ferromagnetique, lorsque la densite d'energie d'anisotropie est de la forme E= K sin{sup 2} {alpha}, l'etude de la propagation des ondes de spin de faible energie a travers une paroi de Bloch, conduit a une equation de Schrodinger a une dimension, dans laquelle figure un puits de potentiel qui a la propriete remarquable d'etre completement transparent quelle que soit l'energie de l'onde incidente. (auteur)

  4. Safety profile of multielectrode-phased radiofrequency pulmonary vein ablation catheter and irrigated radiofrequency catheter.

    Science.gov (United States)

    Wasmer, K; Foraita, P; Leitz, P; Güner, F; Pott, C; Lange, P S; Eckardt, L; Mönnig, G

    2016-01-01

    Silent cerebral lesions with the multielectrode-phased radiofrequency (RF) pulmonary vein ablation catheter (PVAC(®)) have recently been investigated. However, comparative data on safety in relation to irrigated RF ablation are missing. One hundred and fifty consecutive patients (58 ± 12 years, 56 female) underwent first pulmonary vein isolation (PVI) for atrial fibrillation (61% paroxysmal) using PVAC(®) (PVAC). Procedure data as well as in-hospital complications were compared with 300 matched patients who underwent PVI using irrigated RF (iRF). Procedure duration (148 ± 63 vs. 208 ± 70 min; P drainage n = 0 vs. n = 6] occurred more frequently using iRF. Two patients in each group developed a TIA (1.3% vs. 0.6%). Of note, four of five thromboembolic events in the PVAC group (two TIAs and three transient ST elevations during ablation) occurred when all 10 electrodes were used for ablation. Pulmonary vein isolation using PVAC as a 'one-shot-system' has a comparable complication rate but a different risk profile. Pericardial effusion and tamponade occurred more frequently using iRF, whereas thromboembolic events were more prevalent using PVAC. Occurrence of clinically relevant thromboembolic events might be reduced by avoidance of electrode 1 and 10 interaction and uninterrupted anticoagulation, whereas contact force sensing for iRF might minimize pericardial effusion. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  5. Características construtivas e funcionais das agulhas de radiofrequência bipolares resfriadas para reduzir o sangramento nas ressecções hepáticas Construction of radiofrequency cold bipolar needles and its functional aspects to reduce the bleeding in hepatic resections

    Directory of Open Access Journals (Sweden)

    José Artur Sampaio

    2011-06-01

    Full Text Available RACIONAL: Para diminuir o sangramento em ressecções hepáticas diversas opções tecnológicas têm sido divulgadas, dentre elas a radiofrequência. A intenção dos vários métodos é evitar o clampeamento vascular, fazer menor dissecção hepática e obter menor sangramento. OBJETIVO: Apresentar uma nova técnica de agulhas paralelas de radiofrequência bipolar desenvolvidas pelos próprios autores e os detalhes técnicos de seu uso. MÉTODOS: O sistema de agulhas apresenta dois eletrodos paralelos (18 gauge cada de 25 cm de comprimento, separados entre si por uma distância de 1,5 cm, onde apenas os 4 cm distais dissipam energia gerada por um eletrobisturi bipolar. Estas agulhas são refrigeradas através de um sistema de resfriamento interno por fluxo contínuo de água destilada gelada estéril a 0oC, cuja temperatura é mantida através da presença de gelo, formado também por água destilada estéril. A operação é realizada sob anestesia geral, não sendo utilizados cateteres venosos centrais durante ou após o procedimento. As incisões realizadas podem ser subcostal direita e mediana supra-umbilical. RESULTADOS: A experiência inicial de sua utilização nas ressecções hepáticas mostraram média de 87 minutos, tamanho médio da incisão abdominal de 14 cm e sangramento médio de 58 ml. Nenhum paciente do grupo inicial recebeu transfusão de sangue ou derivados. CONCLUSÃO: As agulhas de radiofrequência bipolares resfriadas são viáveis e reduzem o sangramento nas ressecções hepáticas.BACKGROUND: To reduce bleeding in liver resection various technological options have been disclosed, among them the radiofrequency. The intent of the various methods is to avoid vascular clamping, less liver dissection and minimize bleeding. AIM: To present a new technique of parallel bipolar radiofrequency needles developed by the authors and the technical details. METHODS: The needle system has two parallel electrodes (18 gauge each of 25

  6. Radiofrequency power deposition during magnetic resonance diagnostic examinations

    International Nuclear Information System (INIS)

    Grandolfo, M.; Vecchia, P.

    1988-01-01

    Magnetic Resonance Imaging and Spectroscopy (MRI, MRS) require that subjects be exposed to radiofrequency field, and the corresponding energy absorption leads to tissue heating. The main question, thus, to be considered in connection to safety and health aspects is related to the specific absorption rate (SAR) in the imaged subject and the exposure durations which might put a practical limit on the pulse sequence which can be used. In this paper some models and experimental results for radiofrequency power deposition in MRI and MRS machines are reviewed. Models show that energy dissipation is a function of the frequency, RF incident power density, exposure duration, coupling between the RF coil and the subject, and several properties of the exposed tissue, including conductivity, dielectric constant, specific gravity, size, and orientation relative to the field polarization. The ability of the body's normal thermoregulatory responses to cope with high levels of RF energy deposition must be also taken into account

  7. Plasma heating by radiofrequency in the electron cyclotron resonance (ECR)

    International Nuclear Information System (INIS)

    Cunha Raposo, C. da; Aihara, S.; Universidade Estadual de Campinas

    1982-01-01

    The characteristics of the experimental set-up mounted in the Physical Institute of UFF (Brazil) to produce the gas ionization by radio-frequency are shown and its behaviour when confined by a mirror-geometry magnetic field is studied. The diagnostic is made by a langmuir probe and a prisme spectrogaph is used in order to verify the nature of the ionized helium gas and the degree of purity through its spectral lines. The argon ionization by R.f. is produced in the 'LISA' machine obtain a plasma column of approximatelly 60 cm length and with the Langmuir probe the study of the profile distribution of the plasma parameters such as: electron temperature and density and floating potencial in function of the magnetic field variation is made. The main focus is given to the fundamental electron cyclotron resonance (ECR). A new expression on the ion saturation current (I sub(is)) produced by radiofrequency is developed. (L.C.) [pt

  8. Radiofrequency electromagnetic fields in the Cookridge area of Leeds

    CERN Document Server

    Fuller, K; Judd, P M; Lowe, A J; Shaw, J

    2002-01-01

    On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency electromagnetic fields in the environment such as broadcast radio...

  9. Novel high-resolution temperature probe for radiofrequency dosimetry

    International Nuclear Information System (INIS)

    Schuderer, Juergen; Schmid, Thomas; Urban, Gerald; Samaras, Theodoros; Kuster, Niels

    2004-01-01

    A novel integrated thermistor probe for temperature evaluations in radiofrequency-heated environments was realized. The probe's sensitive area is based on a highly resistive 50 μm x 100 μm layer of amorphous germanium processed on a glass tip. The small dimensions allow measurements with a distance as close as 150 μm from solid boundaries. Due to its high temperature resolution of 4 mK and its short response time of the order of 10 ms, the sensor is very well suited for dosimetric measurements in strong absorption gradients. The influence of radiofrequency (RF) electric fields on the signal is minimized due to the high resistance of the sensor and the leads. The probe was successfully used to determine the highly nonuniform absorption distribution resulting from the RF exposure of cell cultures placed in Petri dishes. (note)

  10. First muon acceleration using a radio-frequency accelerator

    Directory of Open Access Journals (Sweden)

    S. Bae

    2018-05-01

    Full Text Available Muons have been accelerated by using a radio-frequency accelerator for the first time. Negative muonium atoms (Mu^{-}, which are bound states of positive muons (μ^{+} and two electrons, are generated from μ^{+}’s through the electron capture process in an aluminum degrader. The generated Mu^{-}’s are initially electrostatically accelerated and injected into a radio-frequency quadrupole linac (RFQ. In the RFQ, the Mu^{-}’s are accelerated to 89 keV. The accelerated Mu^{-}’s are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.

  11. Occupational exposure of NRM spectrometrists to static and radiofrequency fields

    International Nuclear Information System (INIS)

    Berlana, Tania; Ubeda, Alejandro

    2017-01-01

    Occupational exposure to static and radiofrequency fields emitted by nuclear magnetic resonance spectrometers was assessed through systematic field metering during operation of 19 devices in nine research centers. Whereas no measurable levels of radiofrequency radiation were registered outside the spectrometers, significant exposure to static field was detected, with maximum values recorded at the user s hand (B = 683.00 mT) and head thorax (B = 135.70 mT) during spectrometer manipulation. All values were well below the exposure limits set by the European standard for workers protection against the effects of acute field exposure only. As for potential effects of chronic exposure, waiting for more complete knowledge, adoption of technical and operational strategies for exposure minimizing is advisable. In this respect, the data revealed that compared with standard magnetic shielding, ultra-shield technology allows a 20-65-fold reduction of the field strength received by the operator. (authors)

  12. Novel high-resolution temperature probe for radiofrequency dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Schuderer, Juergen [Foundation for Research on Information Technologies in Society (IT' IS), Integrated Systems Laboratory IIS, Swiss Federal Institute of Technology (ETH), CH-8092 Zurich (Switzerland); Schmid, Thomas [Schmid and Partner Engineering AG, 8004 Zurich (Switzerland); Urban, Gerald [IMTEK, Albert-Ludwigs University Freiburg, 79110 Freiburg (Germany); Samaras, Theodoros [Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Kuster, Niels [Foundation for Research on Information Technologies in Society (IT' IS), Integrated Systems Laboratory IIS, Swiss Federal Institute of Technology (ETH), CH-8092 Zurich (Switzerland)

    2004-03-21

    A novel integrated thermistor probe for temperature evaluations in radiofrequency-heated environments was realized. The probe's sensitive area is based on a highly resistive 50 {mu}m x 100 {mu}m layer of amorphous germanium processed on a glass tip. The small dimensions allow measurements with a distance as close as 150 {mu}m from solid boundaries. Due to its high temperature resolution of 4 mK and its short response time of the order of 10 ms, the sensor is very well suited for dosimetric measurements in strong absorption gradients. The influence of radiofrequency (RF) electric fields on the signal is minimized due to the high resistance of the sensor and the leads. The probe was successfully used to determine the highly nonuniform absorption distribution resulting from the RF exposure of cell cultures placed in Petri dishes. (note)

  13. Complications associated with radiofrequency ablation of pulmonary veins.

    Science.gov (United States)

    Madrid Pérez, J M; García Barquín, P M; Villanueva Marcos, A J; García Bolao, J I; Bastarrika Alemañ, G

    Radiofrequency ablation is an efficacious alternative in patients with symptomatic atrial fibrillation who do not respond to or are intolerant to at least one class I or class III antiarrhythmic drug. Although radiofrequency ablation is a safe procedure, complications can occur. Depending on the location, these complications can be classified into those that affect the pulmonary veins themselves, cardiac complications, extracardiac intrathoracic complications, remote complications, and those that result from vascular access. The most common complications are hematomas, arteriovenous fistulas, and pseudoaneurysms at the puncture site. Some complications are benign and transient, such as gastroparesis or diaphragmatic elevation, whereas others are potentially fatal, such as cardiac tamponade. Radiologists must be familiar with the complications that can occur secondary to pulmonary vein ablation to ensure early diagnosis and treatment. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Combined kinetic and transport modeling of radiofrequency current drive

    International Nuclear Information System (INIS)

    Dumont, R.; Giruzzi, G.; Barbato, E.

    2000-07-01

    A numerical model for predictive simulations of radiofrequency current drive in magnetically confined plasmas is developed. It includes the minimum requirements for a self consistent description of such regimes, i.e., a 3-D ,kinetic equation for the electron distribution function, 1-D heat and current transport equations, and resonant coupling between velocity space and configuration space dynamics, through suitable wave propagation equations. The model finds its full application in predictive studies of complex current profile control scenarios in tokamaks, aiming at the establishment of internal transport barriers by the simultaneous use of various radiofrequency current drive methods. The basic properties of this non-linear numerical system are investigated and illustrated by simulations applied to reversed magnetic shear regimes obtained by Lower Hybrid and Electron Cyclotron current drive for parameters typical of the Tore Supra tokamak. (authors)

  15. Maslov Shear-Waveforms in Highly Anisotropic Shales and Implications for Shear-Wave Splitting Analyses Formes d'onde transversales de Maslov dans les argiles fortement anisotropes et implications dans les analyses de biréfringence des ondes transversales

    Directory of Open Access Journals (Sweden)

    Caddick J.

    2006-12-01

    énéralement anisotropes. Dans le présent article, nous calculons les formes d'onde sismiques pour des argiles fortement anisotropes en employant la théorie asymptotique de Maslov (MAT. Cette théorie est une extension de la théorie classique des rayons qui fournit des formes d'onde valides dans les zones des caustiques (repliement du front d'onde, là où les amplitudes de la théorie des rayons sont instables. La théorie asymptotique des rayons (ART est basée sur le rayon géométrique ou rayon de Fermat qui relie la source au récepteur. Par contre, la solution de Maslov intègre les données sur des rayons contigüs qui ne sont pas des rayons de Fermat. Les rayons, les temps de propagation, les amplitudes et les sismogrammes synthétiques sont présentés pour trois argiles fortement anisotropes en utilisant un modèle 1D très simple composé d'une argile anisotrope sus-jacente à une argile isotrope. Les formes d'onde ART ne réussissent pas à rendre compte des effets de formes d'onde complexes dues à la triplication. En comparaison, les formes d'onde MAT prévoient les amplitudes régulières aux sommets du front d'onde et les signaux diffractés à partir de ces sommets. Une solution de Maslov qui intègre les contributions des rayons sur une composante unique de lenteur se détériorera si les rayons se focalisent en 3D (sur un point plutôt que le long d'une ligne. Une des argiles testées exhibe cette caustique, et l'intégration sur deux composantes de lenteur est nécessaire pour éliminer la singularisation en amplitude. Nous examinons enfin les effets des triplications du front d'onde sur les rotations de Alford qui sont utilisées pour évaluer la biréfringence des ondes transversales. Dans de tels cas, la rotation trouve avec succés la polarisation de l'onde transversale rapide, mais elle peut s'avérer peu fiable pour l'estimation de l'écart de temps d'arrivée entre les deux ondes transversales.

  16. Endoscopic release of congenital muscular torticollis with radiofrequency in teenagers.

    Science.gov (United States)

    Wang, Jun-Liang; Qi, Wei; Liu, Yu-Jie

    2018-05-03

    Congenital muscular torticollis (CMT) is due to contracture of the sternocleidomastoid muscle which may cause activity limitations of the neck, tilt of the head, craniofacial asymmetry, and deformity of the skull. The authors present their experience of arthroscopic tight fibrous band release with radiofrequency in teenagers under local anesthesia and evaluate the clinical results. A total of 69 patients who underwent arthroscopic release of CMT with radiofrequency under local anesthesia by a single surgeon could participate in this study. Before operation, surface landmarks of sternocleidomastoid muscle, bone, and neurovascular structures were marked. Local infiltrating anesthesia of the surgical region was then performed. Through a working space created by blunt dissection, the arthroscopy and radiofrequency devices were introduced. Then, the clavicular and sternal heads of the sternocleidomastoid muscle were identified and gradually transected. The patients were followed up postoperatively with Cheng's scoring system. There were 31 male patients and 38 female patients. The mean age of the patients was 16.1 years. The mean length of follow-up in this series was 36.7 months (range, 28 to 67 months). During the operation, 62 patients (89.9%) had no pain, 6 patients (8.7%) felt mild pain, and only 1 patient (1.4%) regarded the procedure as very painful. At all follow-up periods, there were no repeat arthroscopies for any of these patients. At the final follow-up, the average rotation deficit improved from 22.5° to 4.1° postoperatively, and the average lateral bending deficit improved from 14.6° to 3.3° (p radiofrequency under local anesthesia provides surgeons with an alternative to traditional open techniques for the management of congenital muscular torticollis (CMT). Our date shows that this method is minimally invasive and provides good functional recovery with a lower risk of complications.

  17. Diaphragmatic Hernia After Radiofrequency Ablation for Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Matsushima, Shigenori; Tanaka, Osamu; Miura, Hiroshi; Nishimura, Tsunehiko

    2011-01-01

    We describe a 71-year-old woman with a hepatocellular carcinoma who underwent percutaneous radiofrequency ablation (RF) with a single internally cooled electrode under computed tomography (CT) fluoroscopic guidance. Nine months after the procedure, CT images showed herniation of the large intestine into the right pleural cavity. To our knowledge this complication of RF performed with a single internally cooled electrode under CT guidance has not been previously reported.

  18. Radiofrequency thermal ablation of a metastatic lung nodule

    Energy Technology Data Exchange (ETDEWEB)

    Highland, Adrian M. [Department of Clinical Radiology, Hull Royal Infirmary, Anlaby Road, Hull, HU3 2JZ (United Kingdom); Mack, Paul [Diana Princess of Wales Hospital, Scartho Road, Grimsby, DN33 2BA (United Kingdom); Breen, David J. [Department of Radiology, Southampton University Hospitals, Tremona Road, Southampton, SO16 6YD (United Kingdom)

    2002-07-01

    Pulmonary metastases are a common finding in patients with colonic adenocarcinoma. We report the treatment of a metastatic lung nodule with radiofrequency (RF) ablation under CT guidance. This case illustrates the use of RF ablation in a patient in whom surgical resection was no longer possible and where chemotherapy was unlikely to produce benefit. This technique may offer a viable method of cytoreduction when other treatments have not succeeded. (orig.)

  19. Radiofrequency thermal ablation of a metastatic lung nodule

    International Nuclear Information System (INIS)

    Highland, Adrian M.; Mack, Paul; Breen, David J.

    2002-01-01

    Pulmonary metastases are a common finding in patients with colonic adenocarcinoma. We report the treatment of a metastatic lung nodule with radiofrequency (RF) ablation under CT guidance. This case illustrates the use of RF ablation in a patient in whom surgical resection was no longer possible and where chemotherapy was unlikely to produce benefit. This technique may offer a viable method of cytoreduction when other treatments have not succeeded. (orig.)

  20. Pulse-Dose Radiofrequency in Athletic Pubalgia: Preliminary Results.

    Science.gov (United States)

    Masala, Salvatore; Fiori, Roberto; Raguso, Mario; Ojango, Christine; Morini, Marco; Cuzzolino, Alessandro; Calabria, Eros; Simonetti, Giovanni

    2017-05-01

    Chronic pubalgia affects around 10% of athletes. To determine the role of pulse-dose radiofrequency (PDRF) in athletes with chronic pubalgia and investigate the causes with imaging. Prospective nonrandomized single-group study. PDRF was performed on 32 patients with a chronic pain that had been refractory to conservative therapies during the last 3 mo. The genital branches of the genitofemoral, ilioinguinal, and iliohypogastric nerves and the obturator nerve were the goals of treatment. A 10-cm, 20-gauge cannula was inserted with a percutaneous access on the upper and lower edges of the iliopubic branch. After the spindle was removed, a radiofrequency needle with a 10-mm "active tip" was inserted. The radiofrequency technique was performed with 1200 pulses at 45 V and 20-ms duration, followed by a 480-ms silent phase. The follow-up with a clinical examination was performed at 1, 3, 6, and 9 mo after the procedure. During the follow-up visits, the patients were asked to rate their pain on a 0-10 VAS scale. All of the enrolled patients completed the study. Mean VAS score before the treatment was 8.4 ± 0.6. Twenty-four patients had a reduction of pain VAS scores more than 50% during all follow-up visits and started training and physiotherapy in the days after the radiofrequency procedure. Six patients, each treated 2 times, had a reduction more than 50% of VAS scores and could start training and physiotherapy only after the 2nd procedure. One patient had no pain relief with 2 treatments. Pain intensity decreased up to 9 mo in 31 patients (mean VAS scores 3.4 ± 0.5 at 6 mo and 3.8 ± 0.9 at 9 mo). No complications were observed. PDRF is an effective and safe technique in management of chronic pubalgia in athletes.

  1. Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.

    Science.gov (United States)

    Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji

    2010-04-01

    To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.

  2. RADIO-FREQUENCY MASS SPECTROMETERS AND THEIR APPLICATIONS IN SPACE

    Energy Technology Data Exchange (ETDEWEB)

    Gilmour, Jr., A. S.

    1963-08-15

    The operation of three common radio-frequency mass spectrometers is described, and their performances are compared. Their limitations are pointed out. It is concluded that the quadrupole spectrometer has fewer limitations and is more generally useful in space probes than the other devices. Some present and proposed uses of spectrometers in space are discussed, and the problem of contamination of the atmosphere being sampled by the spectrometer is reviewed. (auth)

  3. Diagrams of ion stability in radio-frequency mass spectrometry

    International Nuclear Information System (INIS)

    Sudakov, M.Yu.

    1994-01-01

    For solving radio-frequency mass spectrometry problems and dynamic ion containment are studied and systematized different ways for constructing the ion stability diagrams. A new universal set of parameters is proposed for diagram construction-angular variables, which are the phase raid of ion oscillational motion during positive and negative values of the supplying voltage. An effective analytical method is proposed for optimization of the parameters of the pulsed supplying voltage, in particular its repetition rate

  4. Thermal Ablation for Benign Thyroid Nodules: Radiofrequency and Laser

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan; Lee, Jeong Hyun [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Valcavi, Roberto [Endocrinology Division and Thyroid Disease Center, Arcispedale Santa Maria Nuova, Reggio Emilia (Italy); Pacella, Claudio M. [Diagnostic Imaging and Interventional Radiology Department, Ospedale Regina Apostolorum, Albano Laziale-Rome (IT); Rhim, Hyun Chul [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Na, Dong Kyu [Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of)

    2011-10-15

    Although ethanol ablation has been successfully used to treat cystic thyroid nodules, this procedure is less effective when the thyroid nodules are solid. Radiofrequency (RF) ablation, a newer procedure used to treat malignant liver tumors, has been valuable in the treatment of benign thyroid nodules regardless of the extent of the solid component. This article reviews the basic physics, techniques, applications, results, and complications of thyroid RF ablation, in comparison to laser ablation.

  5. Massive hematemesis after radiofrequency ablation of metastatic liver tumor with successful hemostasis achieved through transarterial embolization.

    Science.gov (United States)

    Liu, Chien-An; Chiu, Nai-Chi; Chiou, Yi-You

    2018-03-03

    Hemorrhagic complications are the most common major complications that occur after radiofrequency ablation, but hematemesis as a complication after radiofrequency ablation for hepatic tumor has not been mentioned before. A hepatogastric fistula as a delayed complication is also rare. We present the case of a 77-year-old man with severe hematemesis that occurred 2 months after radiofrequency ablation of a liver metastasis of gastric cancer. A ruptured hepatic artery pseudoaneurysm and a hepatogastric fistula were confirmed through serial imaging examinations. The current case is reported in combination with 2 rare major complications after radiofrequency ablation of a liver tumor. Copyright © 2018. Published by Elsevier Inc.

  6. Treatment of Décolletage Photoaging With Fractional Microneedling Radiofrequency.

    Science.gov (United States)

    Lyons, Alexis; Roy, Jillian; Herrmann, Jennifer; Chipps, Lisa

    2018-01-01

    The objective of this study was to examine the efficacy and safety of a novel fractional microneedling radiofrequency device to improve the appearance of rhytides and skin laxity of the décolletage. Twelve subjects received a total of three fractional microneedling radiofrequency treatments with Endymed Intensif (EndyMed Ltd., Cesarea, Israel) at least three weeks apart. Primary outcome measure was clinical efficacy quantified by a patient survey to assess treatment satisfaction as well as a physician Global Aesthetic Improvement Scale (GAIS). Photos were taken before every treatment and at a follow-up appointment. Assessments by two board-certified dermatologists revealed an overall improvement in 67% of patients. Seventy percent of subjects rated their post-treatment skin laxity and rhytides as improved, while 60% of patients rated their skin texture as improved. Eighty percent of subjects were at least slightly satisfied with their treatment. Forty percent of subjects would recommend this treatment to others. Subjects in this study demonstrated an overall improvement in décolletage appearance in regard to skin tightening, wrinkles, and skin texture suggested by overall patient satisfaction (80%) and physician-rated GAIS improvement (67%). This study suggests that fractional microneedling radiofrequency devices are a safe and efficacious way to improve overall décolletage appearance with little down time. J Drugs Dermatol. 2018;17(1):74-76..

  7. [Percutaneous radiofrequency ablation of hepatic metastases. Preliminary experience].

    Science.gov (United States)

    De Baere, T; Elias, D; Ducreux, M; Dromain, C; Kuach, V; Gamal El Din, M; Sobotka, A; Lasser, P; Roche, A

    1999-11-01

    To evaluate the efficiency of percutaneous radiofrequency ablation in the treatment of liver metastases. Eighteen patients with 31 liver metastases, mainly from colorectal cancer, 10 - 35 mm in diameter (m = 23), underwent 26 courses of percutaneous radiofrequency ablation. Fifteen patients had previously undergone hepatectomy, and 3 patients had contra-indications to surgery. Imaging guidance was ultrasound in 21 patients, CT in 4 (tumors not seen with ultrasound), and both in 1. A generator working at 450 KHz with a maximum output power of 150 W was used to treat each lesion for 18 - 20 min. Treatment was monitored with real time ultrasound. Among the 12 patients followed more than 3 months, only one of the 24 treated lesions recurred after a mean follow up of 259 ¿ 109 days. Liver disease was controlled in 8 of the 12 patients after 90 - 509 days (m = 306). Among these 8 patients, 3 were tumor free after 559, 378 and 90 days, respectively; 2 died tumor free of non-tumoral disease (pulmonary embolism, digestive bleeding); 3 developed lung metastases treated with chemotherapy (n = 2) or surgery (n = 1). Three of the 12 patients had widespread hepatic tumor occurrence, and one patient died of these metastases. Six patients experienced mild skin burns, but no major complication was observed. Radiofrequency ablation of hepatic metastases appears safe and promising in this preliminary experience. Further investigation is needed.

  8. Lesion size in relation to ablation site during radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A

    1998-01-01

    This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation was perfor......This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation...... was performed during two different flow-velocities in a tissue bath, while electrode contact pressure and position were unchanged. Target temperature was 80 degrees C. Obtained tip temperature, power consumption and lesion dimensions were measured. In vivo lesion volume, depth and width were found significantly.......61 in vitro). We conclude that during temperature controlled radiofrequency ablation lesion size differs for septal and apical left ventricular applications. Differences in convective cooling might play an important role in this respect. This is supported by our in vitro experiments, where increased...

  9. Bipolar Radiofrequency Facet Ablation of the Lumbar Facet Capsule: An Adjunct to Conventional Radiofrequency Ablation for Pain Management.

    Science.gov (United States)

    Jacobson, Robert E; Palea, Ovidiu; Granville, Michelle

    2017-09-01

    Radiofrequency facet ablation (RFA) has been performed using the same technique for over 50 years. Except for variations in electrode size, tip shape, and change in radiofrequency (RF) stimulation parameters, using standard, pulsed, and cooled RF wavelengths, the target points have remained absolutely unchanged from the original work describing RFA for lumbar pain control. Degenerative changes in the facet joint and capsule are the primary location for the majority of lumbar segmental pathology and pain. Multiple studies show that the degenerated facet joint is richly innervated as a result of the inflammatory overgrowth of the synovium. The primary provocative clinical test to justify an RFA is to perform an injection with local anesthetic into the facet joint and the posterior capsule and confirm pain relief. However, after a positive response, the radiofrequency lesion is made not to the facet joint but to the more proximal fine nerve branches that innervate the joint. The accepted target points for the recurrent sensory branch ignore the characteristic rich innervation of the pathologic lumbar facet capsule and assume that lesioning of these recurrent branches is sufficient to denervate the painful pathologic facet joint. This report describes the additional targets and technical steps for further coagulation points along the posterior capsule of the lumbar facet joint and the physiologic studies of the advantage of the bipolar radiofrequency current in this location. Bipolar RF to the facet capsule is a simple, extra step that easily creates a large thermo-coagulated lesion in this capsule region of the pathologic facet joint. Early studies demonstrate bipolar RF to the facet capsule can provide long-term pain relief when used alone for specific localized facet joint pain, to coagulate lumbar facet cysts to prevent recurrence, and to get more extensive pain control by combining it with traditional lumbar RFA, especially when RFA is repeated.

  10. Electrical conductivity of air under the action of a shock wave; Conductivite electrique de l'air sous l'action d'une onde de choc

    Energy Technology Data Exchange (ETDEWEB)

    Thouvenin, Jacques [Commissariat a l' energie atomique et aux energies alternatives - CEA (France)

    1960-07-01

    A method is described for the measurement of the electrical conductivity of a shock wave in air. The results reveal the preponderant part played by the NO molecule. Reprint of a paper published in Comptes rendus des seances de l'Academie des Sciences, t. 250, p. 302-304, sitting of 11 January 1960 [French] On decrit un procede de mesure de la conductivite electrique d'une onde de choc dans l'air. Les resultats font apparaitre le role preponderant joue par la molecule NO. Reproduction d'un article publie dans les Comptes rendus des seances de l'Academie des Sciences, t. 250, p. 302-304, seance du 11 janvier 1960.

  11. Influence of Mild Traumatic Brain Injury (TBI) and Posttraumatic Stress Disorder (PTSD) on Pain Intensity Levels in OEF/OIF/OND Veterans.

    Science.gov (United States)

    Stojanovic, Milan P; Fonda, Jennifer; Fortier, Catherine Brawn; Higgins, Diana M; Rudolph, James L; Milberg, William P; McGlinchey, Regina E

    2016-11-01

    Mild traumatic brain injury (mTBI) and posttraumatic stress disorder (PTSD) are common among US veterans of Operation Enduring Freedom/Operation Iraqi Freedom/Operation New Dawn (OEF/OIF/OND). We postulated that these injuries may modulate pain processing in these individuals and affect their subjective pain levels. Cross-sectional. 310 deployed service members of OEF/OIF/OND without a lifetime history of moderate or severe TBI were included in this study. All participants completed a comprehensive evaluation for Blast Exposure, mTBI, PTSD, and Pain Levels. The Boston Assessment of TBI-Lifetime Version (BAT-L) was used to assess blast exposure and potential brain injury during military service. The Clinician-Administered PTSD Scale (CAPS) characterized presence and severity of PTSD. The Visual Analog Scale (VAS) was used to assess pain intensity over the previous month before the interview, with higher scores indicative of worse pain. Statistical analysis was performed by ANOVA and results were adjusted for co-morbidities, clinical characteristics and demographic data. In comparison to control participants (veterans without mTBI or current PTSD), veterans with both current PTSD and mTBI reported the highest pain intensity levels, followed by veterans with PTSD only (P Pain levels in veterans with mTBI only were comparable to control participants. Comorbid PTSD and mTBI is associated with increased self-reported pain intensity. mTBI alone was not associated with increased pain. Published by Oxford University Press on behalf of the American Academy of Pain Medicine 2016. This work is written by US Government employees and is in the public domain in the US.

  12. Sismonaute. Un système pour la détection et l'interprétation des fronts d'onde en simulation sismique Sismonaute. A System for Detecting and Interpreting Wave Fronts in Seismic Simulations

    Directory of Open Access Journals (Sweden)

    Junker U.

    2006-11-01

    Full Text Available Nous développons un système, dénommé SISMONAUTE, d'aide aux géophysiciens pour l'étude de la propagation des ondes dans un modèle postulé de sous-sol. Le système suit les fronts d'onde dans une série d'instantanés 2D produits par un simulateur numérique. De plus, il rétablit l'historique de l'onde, c'est-à-dire la séquence des réflexions, transmissions et diffractions qui représente des transformations qualitatives de l'onde. Cet historique est essentiel pour la comparaison des sismogrammes simulés et observés. Nous utilisons pour interpréter les données de simulation un système dirigé par les connaissances qui applique le raisonnement causal pour prédire, à chaque stade, de nouveaux fronts d'onde. Ces fronts prédits permettent une détection guidée des fronts d'onde sur les instantanés. We are developing a system, called SISMONAUTE, that supports a geophysicist in studying the propagation of waves in a postulated model of the subsoil. The system tracks the wave fronts in a sequence of 2D-snapshots produced by a numerical simulator. Furthermore, it recovers the history of a wave, i. e. the sequence of reflections, transmissions, and diffractions which represents qualitative changes of the wave. This history is essential for comparing simulated and observed seismograms. We use a knowledge-driven approach to interpret the simulated data. Using causal reasoning, the system predicts new wave fronts in each step. These predicted fronts enable a guided detection of wave fronts in the snapshots.

  13. Study of electronic field emission from large surfaces under static operating conditions and hyper-frequency; Etude de l'emision electronique par effet de champ sur des surfaces larges en regime statique et hyperfrequence

    Energy Technology Data Exchange (ETDEWEB)

    Luong, M

    1997-09-01

    The enhanced electronic field emission from large area metallic surfaces lowers performances of industrial devices that have to sustain high electric field under vacuum. Despite of numerous investigations in the past, the mechanisms of such an emission have never been well clarified. Recently, research in our laboratory has pointed out the importance played by conducting sites (particles and protrusions). A refined geometrical model, called superposed protrusions model has been proposed to explain the enhanced emission by local field enhancement. As a logical continuation, the present work aims at testing this model and, in the same time, investigating the means to suppress the emission where it is undesirable. Thus, we have showed: the cause of current fluctuations in a continuous field regime (DC), the identity of emission characteristics ({beta}, A{sub e}) in both radiofrequency (RF) and DC regimes, the effectiveness of a thermal treatment by extern high density electronic bombardment, the effectiveness of a mechanical treatment by high pressure rinsing with ultra pure water, the mechanisms and limits of an in situ RF processing. Furthermore, the electronic emission from insulating particles has also been studied concurrently with a spectral analysis of the associated luminous emission. Finally, the refined geometrical model for conducting sites is reinforced while another model is proposed for some insulating sites. Several emission suppressing treatments has been explored and validated. At last, the characteristic of a RF pulsed field emitted electron beam has been checked for the first time as a possible application of such a field emission. (author)

  14. Study of electronic field emission from large surfaces under static operating conditions and hyper-frequency; Etude de l'emision electronique par effet de champ sur des surfaces larges en regime statique et hyperfrequence

    Energy Technology Data Exchange (ETDEWEB)

    Luong, M

    1997-09-01

    The enhanced electronic field emission from large area metallic surfaces lowers performances of industrial devices that have to sustain high electric field under vacuum. Despite of numerous investigations in the past, the mechanisms of such an emission have never been well clarified. Recently, research in our laboratory has pointed out the importance played by conducting sites (particles and protrusions). A refined geometrical model, called superposed protrusions model has been proposed to explain the enhanced emission by local field enhancement. As a logical continuation, the present work aims at testing this model and, in the same time, investigating the means to suppress the emission where it is undesirable. Thus, we have showed: the cause of current fluctuations in a continuous field regime (DC), the identity of emission characteristics ({beta}, A{sub e}) in both radiofrequency (RF) and DC regimes, the effectiveness of a thermal treatment by extern high density electronic bombardment, the effectiveness of a mechanical treatment by high pressure rinsing with ultra pure water, the mechanisms and limits of an in situ RF processing. Furthermore, the electronic emission from insulating particles has also been studied concurrently with a spectral analysis of the associated luminous emission. Finally, the refined geometrical model for conducting sites is reinforced while another model is proposed for some insulating sites. Several emission suppressing treatments has been explored and validated. At last, the characteristic of a RF pulsed field emitted electron beam has been checked for the first time as a possible application of such a field emission. (author)

  15. Self-consistent treatment of interacting spin waves at finite temperatures; Etude a temperature finie d'un systeme d'ondes de spin en interaction dans une approximation self-consistante

    Energy Technology Data Exchange (ETDEWEB)

    Bloch, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    A spin wave theory is developed where account is taken of spin wave interactions at finite temperatures. The temperature dependence of the spin wave energies and of the magnetization is derived. The theory is developed for ferro-, ferri-, and antiferromagnets. (author) [French] On expose une theorie d'ondes de spin en interaction a temperature finie. On en deduit l'evolution avec la temperature du spectre en energie des ondes de spin et de l'aimantation. La theorie est developpee pour les corps ferro-, ferri-, et antiferromagnetiques. (auteur)

  16. Exploring channeling optimized radiofrequency energy: a review of radiofrequency history and applications in esthetic fields.

    Science.gov (United States)

    Belenky, Inna; Margulis, Ariel; Elman, Monica; Bar-Yosef, Udi; Paun, Silviu D

    2012-03-01

    Because of its high efficiency and safety, radiofrequency (RF) energy is widely used in the dermatological field for heating biological tissue in various esthetic applications, including skin tightening, skin lifting, body contouring, and cellulite reduction. This paper reviews the literature on the use of nonablative RF energy in the esthetic field and its scientific background. The purpose of this article is to describe in detail the extensive use of medical devices based on RF technology, the development of these medical devices over the years, and recent developments and trends in RF technology. The authors conducted a systematic search of publications that address safety and efficacy issues, technical system specifications, and clinical techniques. Finally, the authors focused on their own clinical experiences with the use of patented Channeling Optimized RF Energy technique and mechanical massage. An in-vivo study was conducted in domestic pigs, with a thermal video camera. Twenty-seven female patients participated in a cellulite and body shaping study. The treatments were conducted according to a three-phase protocol. An additional 16 females participated in a skin tightening case study. All of the patients underwent three treatment sessions at 3-week intervals, each according to a protocol specific to the area being treated. The review of the literature on RF-based systems revealed that these systems are safe, with low risks for potential side effects, and effective for cellulite, body contouring, and skin tightening procedures. The in-vivo measurements confirmed the theory that the penetration depth of RF is an inverse function of its frequency, and using a vacuum mechanism makes an additional contribution to the RF energy penetration. The heating effect of RF was also found to increase blood circulation and to induce collagen remodeling. The results from the cellulite and body shaping treatments showed an overall average improvement of 55% in the

  17. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications.

    Science.gov (United States)

    Trinidad, José Manuel; Carnota, Ana Isabel; Failde, Inmaculada; Torres, Luis Miguel

    2015-01-01

    Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%). The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied). We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  18. Cooled radiofrequency denervation for treatment of sacroiliac joint pain: two-year results from 20 cases

    Science.gov (United States)

    Ho, Kok-Yuen; Hadi, Mohamed Abdul; Pasutharnchat, Koravee; Tan, Kian-Hian

    2013-01-01

    Background Sacroiliac joint pain is a common cause of chronic low back pain. Different techniques for radiofrequency denervation of the sacroiliac joint have been used to treat this condition. However, results have been inconsistent because the variable sensory supply to the sacroiliac joint is difficult to disrupt completely using conventional radiofrequency. Cooled radiofrequency is a novel technique that uses internally cooled radiofrequency probes to enlarge lesion size, thereby increasing the chance of completely denervating the sacroiliac joint. The objective of this study was to evaluate the efficacy of cooled radiofrequency denervation using the SInergy™ cooled radiofrequency system for sacroiliac joint pain. Methods The charts of 20 patients with chronic sacroiliac joint pain who had undergone denervation using the SInergy™ cooled radiofrequency system were reviewed at two years following the procedure. Outcome measures included the Numeric Rating Scale for pain intensity, Patient Global Impression of Change, and Global Perceived Effect for patient satisfaction. Results Fifteen of 20 patients showed a significant reduction in pain (a decrease of at least three points on the Numeric Rating Scale). Mean Numeric Rating Scale for pain decreased from 7.4 ± 1.4 to 3.1 ± 2.5, mean Patient Global Impression of Change was “improved” (1.4 ± 1.5), and Global Perceived Effect was reported to be positive in 16 patients at two years following the procedure. Conclusion Cooled radiofrequency denervation showed long-term efficacy for up to two years in the treatment of sacroiliac joint pain. PMID:23869175

  19. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications

    Directory of Open Access Journals (Sweden)

    José Manuel Trinidad

    2015-01-01

    Full Text Available Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied. We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  20. 21 CFR 880.6300 - Implantable radiofrequency transponder system for patient identification and health information.

    Science.gov (United States)

    2010-04-01

    ... patient identification and health information. 880.6300 Section 880.6300 Food and Drugs FOOD AND DRUG... radiofrequency transponder system for patient identification and health information. (a) Identification. An implantable radiofrequency transponder system for patient identification and health information is a device...

  1. Feasibility of Noninvasive Temperature Assessment During Radiofrequency Liver Ablation on Computed Tomography

    NARCIS (Netherlands)

    Pandeya, Ganga D.; Greuter, Marcel J. W.; de Jong, Koert P.; Schmidt, Bernhard; Flohr, Thomas; Oudkerk, Matthijs

    2011-01-01

    Purpose: The purpose of this study was to assess the feasibility of noninvasive thermometry using high-resolution computer tomography (CT) for the monitoring of bovine liver during radiofrequency (RF) ablation. Methods: Radiofrequency probes were used to ablate bovine livers from 20 degrees C to 98

  2. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  3. Measurement and modelling of a radiofrequency micro-thruster

    International Nuclear Information System (INIS)

    Charles, C; Boswell, R W

    2012-01-01

    A capacitively coupled radiofrequency (rf) (13.56 MHz) cylindrical argon micro-discharge expanding into a larger glass tube is studied by performing optical and electrical measurements over a pressure range 0.3–5 Torr and a rf power range 5–40 W. Measurements of the axial and radial plasma density profiles at the Paschen minimum near 1.5 Torr are used to develop a global model of the discharge and estimate neutral heating from ion–neutral charge exchange collisions for micro-propulsion applications. (fast track communication)

  4. Thyroid radiofrequency ablation: Updates on innovative devices and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Sun; Baek, Jung Hwan; Chung, Sae Rom; Choi, Young Jun; Lee, Jeong Hyun [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Park, Auh Whan [Dept. of Radiology, Vascular and Interventional Radiology Section, University of Virginia Health System, Charlottesville (United States)

    2017-08-01

    Radiofrequency ablation (RFA) is a well-known, effective, and safe method for treating benign thyroid nodules and recurrent thyroid cancers. Thyroid-dedicated devices and basic techniques for thyroid RFA were introduced by the Korean Society of Thyroid Radiology (KSThR) in 2012. Thyroid RFA has now been adopted worldwide, with subsequent advances in devices and techniques. To optimize the treatment efficacy and patient safety, understanding the basic and advanced RFA techniques and selecting the optimal treatment strategy are critical. The goal of this review is to therefore provide updates and analysis of current devices and advanced techniques for RFA treatment of benign thyroid nodules and recurrent thyroid cancers.

  5. Radio-frequency quadrupole: general properties and specific applications

    International Nuclear Information System (INIS)

    Stokes, R.H.; Crandall, K.R.; Hamm, R.W.

    1980-01-01

    The radio-frequency quadrupole (RFQ) linac structure is being developed for the acceleration of low-velocity ions. Recent experimental tests have confirmed its expected performance and have led to an increased interest in a wide range of possible applications. The general properties of RFQ accelerators are reviewed and beam dynamics simulation results are presented for their use in a variety of accelerating systems. These include the low-beta sections of the Fusion Materials Irradiation Test Accelerator, a 200-MHz proton linear accelerator, and a xenon accelerator for heavy ion fusion

  6. Risk assessment and management of radiofrequency radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Dabala, Dana [Railways Medical Clinic Cluj-Napoca, Occupational Medicine Department, 16-20 Bilascu Gheorghe St., 400015 Cluj-Napoca (Romania); Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath St., 400293 Cluj-Napoca (Romania)

    2013-11-13

    Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management.

  7. The emergence of radiofrequency identification tags: applications in surgery.

    Science.gov (United States)

    Schwaitzberg, S D

    2006-08-01

    Radiofrequency identification (RFID) is a wireless method of automatic identification. Currently, RFID tags are emerging into our environment in many aspects of our lives. Applications are being developed in a variety of fields, including health care. Aspects of surgical care will lend themselves to this approach. This technology could provide large amounts of data that not only carry the promise of improving health care, but also may have an impact on personal aspects of our daily lives. Each of us must become familiar with the risks and benefits of RFID use.

  8. Ethical implications of implantable radiofrequency identification (RFID) tags in humans.

    Science.gov (United States)

    Foster, Kenneth R; Jaeger, Jan

    2008-08-01

    This article reviews the use of implantable radiofrequency identification (RFID) tags in humans, focusing on the VeriChip (VeriChip Corporation, Delray Beach, FL) and the associated VeriMed patient identification system. In addition, various nonmedical applications for implanted RFID tags in humans have been proposed. The technology offers important health and nonhealth benefits, but raises ethical concerns, including privacy and the potential for coercive implantation of RFID tags in individuals. A national discussion is needed to identify the limits of acceptable use of implantable RFID tags in humans before their use becomes widespread and it becomes too late to prevent misuse of this useful but ethically problematic technology.

  9. Risk assessment and management of radiofrequency radiation exposure

    International Nuclear Information System (INIS)

    Dabala, Dana; Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia

    2013-01-01

    Radiofrequency radiation (RFR) industry managers, occupational physicians, security department, and other practitioners must be advised on the basic of biophysics and the health effects of RF electromagnetic fields so as to guide the management of exposure. Information on biophysics of RFR and biological/heath effects is derived from standard texts, literature and clinical experiences. Emergency treatment and ongoing care is outlined, with clinical approach integrating the circumstances of exposure and the patient's symptoms. Experimental risk assessment model in RFR chronic exposure is proposed. Planning for assessment and monitoring exposure, ongoing care, safety measures and work protection are outlining the proper management

  10. Measuring Radiofrequency and Microwave Radiation from Varying Signal Strengths

    Science.gov (United States)

    Davis, Bette; Gaul, W. C.

    2007-01-01

    This viewgraph presentation discusses the process of measuring radiofrequency and microwave radiation from various signal strengths. The topics include: 1) Limits and Guidelines; 2) Typical Variable Standard (IEEE) Frequency Dependent; 3) FCC Standard 47 CFR 1.1310; 4) Compliance Follows Unity Rule; 5) Multiple Sources Contribute; 6) Types of RF Signals; 7) Interfering Radiations; 8) Different Frequencies Different Powers; 9) Power Summing - Peak Power; 10) Contribution from Various Single Sources; 11) Total Power from Multiple Sources; 12) Are You Out of Compliance?; and 13) In Compliance.

  11. Measurement uncertainty in broadband radiofrequency radiation level measurements

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2014-01-01

    Full Text Available For the evaluation of measurement uncertainty in the measurement of broadband radio frequency radiation, in this paper we propose a new approach based on the experience of the authors of the paper with measurements of radiofrequency electric field levels conducted in residential areas of Belgrade and over 35 municipalities in Serbia. The main objective of the paper is to present practical solutions in the evaluation of broadband measurement uncertainty for the in-situ RF radiation levels. [Projekat Ministarstva nauke Republike Srbije, br. III43009

  12. Radiofrequency ablation for the treatment of gastric antral vascular ectasia

    DEFF Research Database (Denmark)

    Dray, X.; Repici, A.; Gonzalez, P.

    2014-01-01

    Background and study aims: The traditional endoscopic treatment for gastric antral vascular ectasia (GAVE) is argon plasma coagulation, but results are not always positive. Radiofrequency ablation (RFA) is a new endoscopic therapy that may be an attractive option for the treatment of GAVE. The aim...... of this study was to assess the efficacy and safety of RFA for the treatment of GAVE. Patients and methods: This was an open-label, retrospective, case series study. The main outcome measures were number of red blood cell (RBC) packs transfused (transfusion requirement) and hemoglobin concentrations (g...

  13. Time-of-Flight Positron Emission Tomography with Radiofrequency Phototube

    International Nuclear Information System (INIS)

    Margaryan, A.; Kakoyan, V.; Knyazyan, S.

    2011-01-01

    In this paper γ-detector, based on the radiofrequency (RF) phototube and recently developed fast and ultrafast scintillators, is considered for Time-of-Flight positron emission tomography applications. Timing characteristics of such a device has been investigated by means of a dedicated Monte Carlo code based on the single photon counting concept. Biexponential timing model for scintillators have been used. The calculations have shown that such a timing model is in a good agreement with recently measured data. The timing resolution of -detectors can be significantly improved by using the RF phototube. (authors)

  14. Parallel simulation of radio-frequency plasma discharges

    International Nuclear Information System (INIS)

    Fivaz, M.; Howling, A.; Ruegsegger, L.; Schwarzenbach, W.; Baeumle, B.

    1994-01-01

    The 1D Particle-In-Cell and Monte Carlo collision code XPDP1 is used to model radio-frequency argon plasma discharges. The code runs faster on a single-user parallel system called MUSIC than on a CRAY-YMP. The low cost of the MUSIC system allows a 24-hours-per-day use and the simulation results are available one to two orders of magnitude quicker than with a super computer shared with other users. The parallelization strategy and its implementation are discussed. Very good agreement is found between simulation results and measurements done in an experimental argon discharge. (author) 2 figs., 3 refs

  15. Electromagnetic induction imaging with a radio-frequency atomic magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Deans, Cameron; Marmugi, Luca, E-mail: l.marmugi@ucl.ac.uk; Hussain, Sarah; Renzoni, Ferruccio [Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2016-03-07

    We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future generation of imaging instruments, which combine magnetic induction tomography and the unmatched performance of atomic magnetometers.

  16. Fractionated bipolar radiofrequency and bipolar radiofrequency potentiated by infrared light for treating striae: A prospective randomized, comparative trial with objective evaluation.

    Science.gov (United States)

    Harmelin, Yona; Boineau, Dominique; Cardot-Leccia, Nathalie; Fontas, Eric; Bahadoran, Philippe; Becker, Anne-Lise; Montaudié, Henri; Castela, Emeline; Perrin, Christophe; Lacour, Jean-Philippe; Passeron, Thierry

    2016-03-01

    Very few treatments for striae are based on prospective randomized trials. The objective of this study was to assess the efficacy of bipolar fractional radiofrequency and bipolar radiofrequency potentiated with infrared light, alone or combined, for treating abdominal stretch marks. Bicentric prospective interventional randomized controlled trial in the department of Dermatology of University Hospital of Nice and Aesthetics Laser Center of Bordeaux, France. Men and women of age 18 years or above, who presented for the treatment of mature or immature abdominal striae were included. The patients' abdomens were divided into four equal quadrants. Bipolar radiofrequency potentiated with infrared light and fractional bipolar radiofrequency were applied, alone or combined, and compared to the remaining untreated quadrant. The main criterion of evaluation was the measurement of depth of striae, using 3D photography at 6 months follow-up. A global assessment was also rated by the physician performing the treatment and by the patients. Histological analysis and confocal laser microscopy were additionally performed. A total of 22 patients were enrolled, and 384 striae were measured. In per protocol analysis mean striae depth was decreased by 21.64%, observed at 6 months follow-up with the combined approach, compared to an increase of 1.73% in the control group (P radiofrequency, combined with bipolar radiofrequency potentiated by infrared light, is an effective treatment of both immature and mature striae of the abdomen. © 2016 Wiley Periodicals, Inc.

  17. Presença de Lutzomyia longipalpis em foco de leishmaniose visceral americana onde o vetor provável é somente o Lutzomyia cruzi. Corumbá, Mato Grosso do Sul

    OpenAIRE

    Santos, Soraya Oliveira dos; Arias, Jorge R.; Hoffmann, Marta de Paiva; Furlan, Mara Beatriz Grotta; Ferreira, Wilson Francisco; Pereira, Claucio; Ferreira, Lourival

    2003-01-01

    The present communication reports the presence of Lutzomyia longipalpis in Corumbá, Mato Grosso do Sul, where the principal vector is Lutzomyia cruzi.A presente comunicação relata a presença do Lutzomyia longipalpis em Corumbá, Mato Grosso do Sul, onde o vetor principal é o Lutzomyia cruzi.

  18. Combination acetabular radiofrequency ablation and cementoplasty using a navigational radiofrequency ablation device and ultrahigh viscosity cement: technical note.

    Science.gov (United States)

    Wallace, Adam N; Huang, Ambrose J; Vaswani, Devin; Chang, Randy O; Jennings, Jack W

    2016-03-01

    Percutaneous radiofrequency ablation and cementoplasty is an alternative palliative therapy for painful metastases involving axial load-bearing bones. This technical report describes the use of a navigational radiofrequency probe to ablate acetabular metastases from an anterior approach followed by instillation of ultrahigh viscosity cement under CT-fluoroscopic guidance. The tumor ablation databases of two institutions were retrospectively reviewed to identify patients who underwent combination acetabular radiofrequency ablation and cementoplasty using the STAR Tumor Ablation and StabiliT Vertebral Augmentation Systems (DFINE; San Jose, CA). Pre-procedure acetabular tumor volume was measured on cross-sectional imaging. Pre- and post-procedure pain scores were measured using the Numeric Rating Scale (10-point scale) and compared. Partial pain improvement was categorically defined as ≥ 2-point pain score reduction. Patients were evaluated for evidence of immediate complications. Electronic medical records were reviewed for evidence of delayed complications. During the study period, 12 patients with acetabular metastases were treated. The median tumor volume was 54.3 mL (range, 28.3-109.8 mL). Pre- and post-procedure pain scores were obtained from 92% (11/12) of the cohort. The median pre-procedure pain score was 8 (range, 3-10). Post-procedure pain scores were obtained 7 days (82%; 9/11), 11 days (9.1%; 1/11) or 21 days (9.1%; 1/11) after treatment. The median post-treatment pain score was 3 (range, 1-8), a statistically significant difference compared with pre-treatment (P = 0.002). Categorically, 73% (8/11) of patients reported partial pain relief after treatment. No immediate symptomatic complications occurred. Three patients (25%; 3/12) were discharged to hospice within 1 week of treatment. No delayed complications occurred in the remaining 75% (9/12) of patients during median clinical follow-up of 62 days (range, 14-178 days). Palliative percutaneous

  19. Probing the fundamental limit of niobium in high radiofrequency fields by dual mode excitation in superconducting radiofrequency cavities

    International Nuclear Information System (INIS)

    Eremeev, Grigory; Geng, Rongli; Palczewski, Ari

    2011-01-01

    We have studied thermal breakdown in several multicell superconducting radiofrequency cavity by simultaneous excitation of two TM 010 passband modes. Unlike measurements done in the past, which indicated a clear thermal nature of the breakdown, our measurements present a more complex picture with interplay of both thermal and magnetic effects. JLab LG-1 that we studied was limited at 40.5 MV/m, corresponding to B peak = 173 mT, in 89 mode. Dual mode measurements on this quench indicate that this quench is not purely magnetic, and so we conclude that this field is not the fundamental limit in SRF cavities

  20. A review of micro-wave techniques in plasma studies; Survol des techniques micro-ondes pour l'etude des plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The problem of the application of micro-wave techniques to the study of plasma properties is considered in this report. In section I, the author summarizes a few fundamental laws concerning the theory of waves in an ionised medium as well as measurable effects of transverse and longitudinal propagation. Section II is a rapid review of the experimental methods and of the various measurements which may be effected in very high frequency plasmas. Only recent experimental work carried out since the last U. R.S.I. Assembly is considered. Section III is devoted to micro-wave techniques developed during this period in the laboratories of the Applied Physics Service. These techniques deal with longitudinal propagation and in particular with the propagation along a right mode. Section IV is a general view of similar studies undertaken in European Research Centres working on plasma physics or controlled fusion. Section V is a contribution concerning three particular topics from the Juelich and Max Planck Institute laboratories. (author) [French] On etudie dans ce rapport le probleme de l'application des techniques micro-ondes a l'etude des proprietes d'un plasma. Dans la section I, l'auteur rappelle rapidement quelques lois fondamentales de la theorie des ondes dans un milieu ionise ainsi que les effets mesurables en propagation transversale et longitudinale. La section II est une revue rapide des methodes experimentales et des diverses mesures qui peuvent etre faites dans les plasmas aux tres hautes frequences. On ne considere seulement que les etudes experimentales recentes depuis la derniere assemblee de l'U.R.S.I. La section III est consacree aux techniques hyperfrequences developpees durant la meme periode dans les laboratoires des Services de Physique Appliquee. Ces techniques se rapportent a la propagation longitudinale et particulierement a la propagation suivant le mode droit. La section IV est un panorama de travaux similaires entrepris dans les centres europeens

  1. Radiofrequency ablation of lung and liver lesions using CT fluoroscopy

    International Nuclear Information System (INIS)

    Chai, A.; Glenn, D.

    2002-01-01

    Full text: Tumour ablation with radiofrequency (RF) energy is a relatively new procedure for the treatment of focal malignant disease. At our institution this is currently being used in the treatment of certain liver and lung lesions with the patients involved being enrolled in clinical trials. The poster describes the technique used at our institution for the placement of the radiofrequency ablation electrode using CT fluoroscopy. Criteria for patient selection are included. Complications from the procedure are described, as well as follow up appearances and results. Our results from the treatment of primary and secondary lesions in the liver correlate well with published literature. Treatment is still not as successful as surgical resection but there is significantly less morbidity. Where this method may be appropriate is when the patient is not a candidate for surgical resection. The treatment of colorectal metastases in the lung shows early promise as a possible second line treatment (as for liver) where the patient is not a candidate for surgery. Preliminary results are soon to be published in conjunction with the Department of Surgery at our institution. RF Electrode placement using CT Fluoroscopy is performed at our institution. While still at its early stages, RF Ablation shows promise as a possible second line treatment (with other adjuvant therapy) for the management of focal malignant disease in the lung and liver. Copyright (2002) Blackwell Science Pty Ltd

  2. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    Energy Technology Data Exchange (ETDEWEB)

    Gevargez, A.; Schirp, S.; Braun, M. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); Groenemeyer, D. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); EFMT Development and Research Center for Microtherapy, Bochum (Germany)

    2002-06-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  3. Osteoid Osteoma: Experience with Laser- and Radiofrequency-Induced Ablation

    International Nuclear Information System (INIS)

    Gebauer, Bernhard; Tunn, Per-Ulf; Gaffke, Gunnar; Melcher, Ingo; Felix, Roland; Stroszczynski, Christian

    2006-01-01

    The purpose of this study was to analyze the clinical outcome of osteoid osteoma treated by thermal ablation after drill opening. A total of 17 patients and 20 procedures were included. All patients had typical clinical features (age, pain) and a typical radiograph showing a nidus. In 5 cases, additional histological specimens were acquired. After drill opening of the osteoid osteoma nidus, 12 thermal ablations were induced by laser interstitial thermal therapy (LITT) (9F Power-Laser-Set; Somatex, Germany) and 8 ablations by radiofrequency ablation (RFA) (RITA; StarBurst, USA). Initial clinical success with pain relief has been achieved in all patients after the first ablation. Three patients had an osteoid osteoma recurrence after 3, 9, and 10 months and were successfully re-treated by thermal ablation. No major complication and one minor complication (sensible defect) were recorded. Thermal ablation is a safe and minimally invasive therapy option for osteoid osteoma. Although the groups are too small for a comparative analysis, we determined no difference between laser- and radiofrequency-induced ablation in clinical outcome after ablation

  4. Percutaneous radiofrequency ablation of spleen for the treatment of hypersplenism

    International Nuclear Information System (INIS)

    Wu Yuxuan; Zhang Yanfang; Zheng Xuefen; Zhang Yuanhua; Kong Jian; Shen Xinying; Dou Yongchong

    2009-01-01

    Objective: To summarize the clinical effect and experience of CT-guided radiofrequency ablation (RFA) of spleen by using cool-tip electrodes in the treatment of hypersplenism in patients with liver cirrhosis and portal hypertension. Methods: CT-guided RFA of spleen by using cool-tip electrodes was performed in 15 patients with hypersplenism associated with liver cirrhosis and portal hypertension. The routine blood count was studied both before and after the procedure. Enhanced CT or MR scanning was reexamined after the treatment to determine the ablated volume of the spleen. The results were statistically analyzed. Results: The ablated volume of the spleen accounted for (31.0 ± 4.6)% of the whole spleen. Before the treatment the platelet count was (62 ± 9.8) x 10 9 /L. One month after the treatment, the platelet count was increased to (96 ± 11) x 10 9 /L, which was significantly higher than that before the treatment (P<0.05). One patient developed portal thrombosis four months after RFA, and no other serious complications occurred. Conclusion: CT-guided radiofrequency ablation of spleen by using cool-tip electrodes is an effective and safe treatment for hypersplenism in patients with liver cirrhosis and portal hypertension. (authors)

  5. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    International Nuclear Information System (INIS)

    Gevargez, A.; Schirp, S.; Braun, M.; Groenemeyer, D.

    2002-01-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  6. Simulation of radiofrequency ablation in real human anatomy.

    Science.gov (United States)

    Zorbas, George; Samaras, Theodoros

    2014-12-01

    The objective of the current work was to simulate radiofrequency ablation treatment in computational models with realistic human anatomy, in order to investigate the effect of realistic geometry in the treatment outcome. The body sites considered in the study were liver, lung and kidney. One numerical model for each body site was obtained from Duke, member of the IT'IS Virtual Family. A spherical tumour was embedded in each model and a single electrode was inserted into the tumour. The same excitation voltage was used in all cases to underline the differences in the resulting temperature rise, due to different anatomy at each body site investigated. The same numerical calculations were performed for a two-compartment model of the tissue geometry, as well as with the use of an analytical approximation for a single tissue compartment. Radiofrequency ablation (RFA) therapy appears efficient for tumours in liver and lung, but less efficient in kidney. Moreover, the time evolution of temperature for a realistic geometry differs from that for a two-compartment model, but even more for an infinite homogenous tissue model. However, it appears that the most critical parameters of computational models for RFA treatment planning are tissue properties rather than tissue geometry. Computational simulations of realistic anatomy models show that the conventional technique of a single electrode inside the tumour volume requires a careful choice of both the excitation voltage and treatment time in order to achieve effective treatment, since the ablation zone differs considerably for various body sites.

  7. Radiofrequency neurolysis in a clinical model. Neuropathological correlation

    International Nuclear Information System (INIS)

    Smith, H.P.; McWhorter, J.M.; Challa, V.R.

    1981-01-01

    Reports differ on which nerve fibers are affected by radiofrequency lesions made in peripheral nerves, some stating that primarily the myelinated delta and unmyelinated C fibers are destroyed, others stating that the destruction affects all sizes of nerve fibers and both myelinated and unmyelinated fibers. This study was designed to confirm one of those two findings, and to study the role that different temperatures might play in determining which fibers are affected. Radiofrequency lesions (85 degrees C for 2 minutes) were made in dogs by placing a temperature-monitored electrode into the lumber intervertebral foramina. The dogs were killed at intervals up to 6 weeks after rhizotomy, and the lesions were studied by light and electron microscopy. In all lesions, there was a total loss of unmyelinated fibers and a nearly total loss of myelinated fibers. In other dogs, 2-minute lesions were made at 45 degrees, 55 degrees, 65 degrees, and 75 degrees C, and the lesions examined 1 week later. Again, all sizes and all types of fibers were destroyed

  8. Effects of 900 MHz radiofrequency radiation on skin hydroxyproline contents.

    Science.gov (United States)

    Çam, Semra Tepe; Seyhan, Nesrin; Kavaklı, Cengiz; Çelikbıçak, Ömür

    2014-09-01

    The present study aimed to investigate the possible effect of pulse-modulated radiofrequency radiation (RFR) on rat skin hydroxyproline content, since skin is the first target of external electromagnetic fields. Skin hydroxyproline content was measured using liquid chromatography mass spectrometer method. Two months old male wistar rats were exposed to a 900 MHz pulse-modulated RFR at an average whole body specific absorption rate (SAR) of 1.35 W/kg for 20 min/day for 3 weeks. The radiofrequency (RF) signals were pulse modulated by rectangular pulses with a repetition frequency of 217 Hz and a duty cycle of 1:8 (pulse width 0.576 ms). A skin biopsy was taken at the upper part of the abdominal costa after the exposure. The data indicated that whole body exposure to a pulse-modulated RF radiation that is similar to that emitted by the global system for mobile communications (GSM) mobile phones caused a statistically significant increase in the skin hydroxyproline level (p = 0.049, Mann-Whitney U test). Under our experimental conditions, at a SAR less than the International Commission on Non-Ionizing Radiation Protection safety limit recommendation, there was evidence that GSM signals could alter hydroxyproline concentration in the rat skin.

  9. [Clinical effect of bipolar radiofrequency thermotherapy on allergic rhinitis].

    Science.gov (United States)

    Oyake, Daisuke; Ochi, Kentaro; Takatsu, Mitsuharu; Shintani, Toshiharu; Umehara, Tsuyoshi; Koizuka, Izumi

    2004-07-01

    The clinical effect of bipolar radiofrequency thermotherapy on allergic rhinitis was evaluated. A bipolar radiofrequency system (CelonLab ENT) was used to treat 16 patients suffering from allergic rhinitis between February 2003 and August 2003. The thermotherapy was performed under local anesthesia at the otolaryngology outpatient clinic of St. Marianna University Toyoko Hospital. Data were collected by questionnaire and rhinomanometry preoperatively and 2 months postoperatively. The mean visual analogue scale (VAS) score for intraoperative pain was 31 mm (range, 0-100), and nearly all the patients felt no or a subtle pain during the thermotherapy. Postoperative pain was also well tolerated, with nearly all the patients not requiring analgesic drugs. Postoperative bleeding was minor, and none of the patients required additional treatment for bleeding. Nearly all the patients reported an improvement in their nasal patency, rhinorrhea, headaches, and sleeping. Statistically significant improvements were observed for all the measured VAS scores: nasal patency, rhinorrhea, headache, and olfactory function. Nasal resistance, as measured by anterior rhinomanometry, significantly improved after treatment. The effect of decongestion was also measured using anterior rhinomanometry. The ratio of nasal resistance before and after decongestion was significantly higher after thermotherapy, suggesting that nasal decongestion had a smaller effect on nasal patency after treatment. The current results suggest that the CelonLab ENT device is an effective and safe treatment for allergic rhinitis.

  10. The biological effects of quadripolar radiofrequency sequential application: a human experimental study.

    Science.gov (United States)

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-10-01

    An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening.

  11. Treatment of Benign Thyroid Nodules: Comparison of Surgery with Radiofrequency Ablation.

    Science.gov (United States)

    Che, Y; Jin, S; Shi, C; Wang, L; Zhang, X; Li, Y; Baek, J H

    2015-07-01

    Nodular goiter is one of the most common benign lesions in thyroid nodule. The main treatment of the disease is still the traditional surgical resection, however there are many problems such as general anesthesia, surgical scar, postoperative thyroid or parathyroid function abnormalities, and high nodules recurrence rate in residual gland. The purpose of this study was to compare the efficacy, safety, and cost-effectiveness of 2 treatment methods, surgery and radiofrequency ablation, for the treatment of benign thyroid nodules. From May 2012 to September 2013, 200 patients with nodular goiters who underwent surgery (group A) and 200 patients treated by radiofrequency ablation (group B) were enrolled in this study. Inclusion criteria were the following: 1) cosmetic problem, 2) nodule-related symptoms, 3) hyperfunctioning nodules related to thyrotoxicosis, and 4) refusal of surgery (for group B). An internally cooled radiofrequency ablation system and an 18-ga internally cooled electrode were used. We compared the 2 groups in terms of efficacy, safety, and cost-effectiveness during a 1-year follow-up. After radiofrequency ablation, the nodule volume decreased significantly from 5.4 to 0.4 mL (P = .002) at the 12-month follow-up. The incidence of complications was significantly higher from surgery than from radiofrequency ablation (6.0% versus 1.0%, P = .002). Hypothyroidism was detected in 71.5% of patients after surgery but in none following radiofrequency ablation. The rate of residual nodules (11.9% versus 2.9%, P = .004) and hospitalization days was significantly greater after surgery (6.6 versus 2.1 days, P radiofrequency ablation are both effective treatments of nodular goiter. Compared with surgery, the advantages of radiofrequency ablation include fewer complications, preservation of thyroid function, and fewer hospitalization days. Therefore, radiofrequency ablation should be considered a first-line treatment for benign thyroid nodules. © 2015 by American

  12. Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.

    Science.gov (United States)

    Wood, Mark; Goldberg, Scott; Lau, Melissa; Goel, Aneesh; Alexander, Daniel; Han, Frederick; Feinstein, Shawn

    2011-06-01

    The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. Fifteen radiofrequency lesions of 6 to 240 seconds in duration were applied to the left ventricular surface of isolated perfused pig hearts. At the end of radiofrequency delivery, a thermal image of the tissue surface was acquired with an infrared camera. The lesion was then stained and an optical image of the lesion was obtained. The thermal and optical images were electronically merged to allow determination of the tissue temperature at the edge of the lesion at the end of radiofrequency delivery. By adjusting the temperature overlay display to conform with the edge of the radiofrequency lesion, the lethal isotherm was measured to be 60.6°C (interquartile ranges, 59.7° to 62.4°C; range, 58.1° to 64.2°C). The areas encompassed by the lesion border in the optical image and the lethal isotherm in the thermal image were statistically similar and highly correlated (Spearman ρ=0.99, Pradiofrequency delivery or to lesion size (both P>0.64). The areas circumscribed by 50°C isotherms were significantly larger than the areas of the lesions on optical imaging (P=0.002). By direct measurement, the lethal isotherm for cardiac myocardium is near 61°C for radiofrequency energy deliveries radiofrequency ablation is important to clinical practice as well as mathematical modeling of radiofrequency lesions.

  13. Departure from Local Thermodynamic Equilibrium in argon plasmas sustained in a Torche à Injection Axiale sur Guide d'Ondes

    International Nuclear Information System (INIS)

    Rincón, R.; Muñoz, J.; Calzada, M.D.

    2015-01-01

    Plasma torches are suitable plasma sources for a wide range of applications. The capability of these discharges to produce processes like sample excitation or decomposition of molecules inside them depends on the density of the plasma species and their energies (temperatures). The relation between these parameters determines the specific state of thermodynamic equilibrium in the discharge. Thus, the understanding of plasma possibilities for application purposes is related to the knowledge of the plasma thermodynamic equilibrium degree. In this paper a discussion about the equilibrium state for Ar plasmas generated by using a Torche à Injection Axiale sur Guide d'Ondes, TIAGO device, is presented. Emission spectroscopy techniques were used to measure gas temperature and electron density at the exit of the nozzle torch and along the dart. Boltzmann-plots as well as b p parameters were calculated to characterize the type and degree of departure from partial Local Saha Equilibrium (pLSE). This study indicates that the closer situation to Local Thermodynamic Equilibrium (LTE) of the plasma corresponds to larger Ar flows which highlights the importance of the nitrogen (atmosphere surrounding the plasma) in the kinetics of Ar-TIAGO discharges. - Highlights: • Discharges sustained in Ar using a TIAGO Torch show a significant departure from Local Thermodynamic Equilibrium. • Nitrogen entrance from surrounding air highly influences Thermodynamic Equilibrium. • Departure from LTE has been studied by means of Boltzmann plots and b p parameters. • The discharge is ionizing at the nozzle exit plasma, while along the dart it becomes recombining

  14. Application of numerical methods to the determination of molecular wave functions; Application de methodes de calcul numerique a la determination de fonctions d'onde moleculaires

    Energy Technology Data Exchange (ETDEWEB)

    Douady, Jerome

    1969-10-01

    A simplified SCF Method is developed. The wave function of molecular systems and spin densities in the case of free radicals are computed from geometrical data. This method, including at the beginning a delocalization of electrons over all the molecular system, two methods which clear out bonding and anti-bonding interactions have been studied and programmed: a) overlap population analysis, b) localisation of molecular orbitals. These methods have been carried out in the case of organic compounds and free radicals. (author) [French] Mise en oeuvre d'une methode de champ self-consistant simplifie qui, a partir des donnees geometriques, permet de calculer la fonction d'onde des systemes moleculaires et les densites de spin dans le cas des radicaux libres. Cette methode introduisant au depart une delocalisation des electrons sur tout le systeme moleculaire, deux methodes permettant de rendre compte du caractere liant et antiliant de ces electrons ont ete etudiees et programmees: a) analyse des populations de recouvrement, b) localisation des orbitales moleculaires. Ces methodes ont ete appliquees a divers composes organiques radicalaires et non radicalaires. (auteur)

  15. TV Móvel: onde estamos e para onde vamos

    Directory of Open Access Journals (Sweden)

    Clara-Luz Álvarez

    2010-05-01

    Full Text Available O artigo apresenta (1 as características técnicas da TV Móvel [Mobile TV] e sua diferença para o IPTV e a TV pela Internet [Internet TV], (2 as questões relativas a rede, espectro e equipamento que influenciarão o arcabouço normativo, (3 as oportunidades geradas para a TV Móvel quando da migração para a TV digital, e (4 um estudo de caso do México pertinente ao marco regulatório dos serviços de telecomunicações e de radiodifusão, aos atores do mercado, à disponibilidade de espectro, à migração para a TV digital e outras questões proeminentes para a TV Móvel.

  16. Radiofrequency radiation injures trees around mobile phone base stations.

    Science.gov (United States)

    Waldmann-Selsam, Cornelia; Balmori-de la Puente, Alfonso; Breunig, Helmut; Balmori, Alfonso

    2016-12-01

    In the last two decades, the deployment of phone masts around the world has taken place and, for many years, there has been a discussion in the scientific community about the possible environmental impact from mobile phone base stations. Trees have several advantages over animals as experimental subjects and the aim of this study was to verify whether there is a connection between unusual (generally unilateral) tree damage and radiofrequency exposure. To achieve this, a detailed long-term (2006-2015) field monitoring study was performed in the cities of Bamberg and Hallstadt (Germany). During monitoring, observations and photographic recordings of unusual or unexplainable tree damage were taken, alongside the measurement of electromagnetic radiation. In 2015 measurements of RF-EMF (Radiofrequency Electromagnetic Fields) were carried out. A polygon spanning both cities was chosen as the study site, where 144 measurements of the radiofrequency of electromagnetic fields were taken at a height of 1.5m in streets and parks at different locations. By interpolation of the 144 measurement points, we were able to compile an electromagnetic map of the power flux density in Bamberg and Hallstadt. We selected 60 damaged trees, in addition to 30 randomly selected trees and 30 trees in low radiation areas (n=120) in this polygon. The measurements of all trees revealed significant differences between the damaged side facing a phone mast and the opposite side, as well as differences between the exposed side of damaged trees and all other groups of trees in both sides. Thus, we found that side differences in measured values of power flux density corresponded to side differences in damage. The 30 selected trees in low radiation areas (no visual contact to any phone mast and power flux density under 50μW/m 2 ) showed no damage. Statistical analysis demonstrated that electromagnetic radiation from mobile phone masts is harmful for trees. These results are consistent with the fact

  17. Flexible small size radiofrequency plasma torch for Tokamak wall cleaning

    International Nuclear Information System (INIS)

    Eusebiu-Rosini Ionita; Luciu, I.; Dinescu, G.; Grisolia, Ch.

    2006-01-01

    Tritium accumulation in walls is a limiting factor in efficient long term operation of fusion machines. A number of detritiation techniques are under study, like laser, discharge, flash lamp based cleaning. One of the encountered difficulties is the limited access of the detritiation tool in narrow spaces, as in divertor region, inter-tiles or inside castellated gaps, where in fact an enhanced co-deposition and tritium trapping were observed. This contribution addresses the problem of elaboration of plasma torch as a tool appropriate for stimulating detritiation and removal of co-deposited layers in such spaces. The requirements imposed to the plasma torch source were related to the compatibility with inside torus operation: small diameter in order to permit access in narrow spaces, reasonable power, large range of working pressures from vacuum to atmosphere, closed loop cooling, flexibility in order to allow scanning and mounting on a robotic arm. The approached design is based on a radiofrequency discharge constricted to burn in a closed space between an active radiofrequency electrode and a grounded nozzle, from where plasma expands outside as a directional beam. The found solutions have led to a flexible hand held source working stable up to 300 W injected power and consisting of a cylindrical body of 20 mm diameter including the external water jacket embracing the discharge and an inside cooling circuit. The electrical characterization of the radiofrequency discharge sustaining the expanded plasma was performed and the domain of stable source operation in terms of power, current, pressure, argon mass flow rate is presented and discussed. The plasma beam size presents a strong dependence on pressure: the plasma length decreases from 200 mm to 20 mm, when pressure increases from vacuum to atmospheric, depending on power and mass flow rate. The ionized gas temperature, as indicated by a thermocouple head inserted in expansion in the nozzle proximity fall in the

  18. One-year results of the use of endovenous radiofrequency ablation utilising an optimised radiofrequency-induced thermotherapy protocol for the treatment of truncal superficial venous reflux.

    Science.gov (United States)

    Badham, George E; Dos Santos, Scott J; Lloyd, Lucinda Ba; Holdstock, Judy M; Whiteley, Mark S

    2018-06-01

    Background In previous in vitro and ex vivo studies, we have shown increased thermal spread can be achieved with radiofrequency-induced thermotherapy when using a low power and slower, discontinuous pullback. We aimed to determine the clinical success rate of radiofrequency-induced thermotherapy using this optimised protocol for the treatment of superficial venous reflux in truncal veins. Methods Sixty-three patients were treated with radiofrequency-induced thermotherapy using the optimised protocol and were followed up after one year (mean 16.3 months). Thirty-five patients returned for audit, giving a response rate of 56%. Duplex ultrasonography was employed to check for truncal reflux and compared to initial scans. Results In the 35 patients studied, there were 48 legs, with 64 truncal veins treated by radiofrequency-induced thermotherapy (34 great saphenous, 15 small saphenous and 15 anterior accessory saphenous veins). One year post-treatment, complete closure of all previously refluxing truncal veins was demonstrated on ultrasound, giving a success rate of 100%. Conclusions Using a previously reported optimised, low power/slow pullback radiofrequency-induced thermotherapy protocol, we have shown it is possible to achieve a 100% ablation at one year. This compares favourably with results reported at one year post-procedure using the high power/fast pullback protocols that are currently recommended for this device.

  19. Theoretical and experimental study of a non-linear disintegration process for a langmuir wave; Etude theorique et experimental d'un processus non lineaire de desintegration d'une onde de langmuir

    Energy Technology Data Exchange (ETDEWEB)

    Perulli, M [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Using the Vlasov equation we calculate and discuss non-linear coupling equations between three electronic plasma waves (Langmuir waves) which propagate in a cylindrical plasma column confined by a strong magnetic field. We study, in the experimental device EOS, along the magnetic field, the disintegration of a Langmuir wave excited in the plasma column by means of an antenna. Space structure measurements for various waves show that the resonance conditions (selection rules) are satisfied. The measured disintegration threshold is in agreement with the theoretical value within 30 per cent and shows that this non linear mechanism appears when the oscillating density to the mean density ratio is about 10{sup -3} to 10{sup -2}. The variation of the spatial growth rate as a function of the amplitude of the disintegrated wave shows that the resulting waves are correlated in groups of three along the magnetic field even though the disintegrating spectrum appears in a wide frequency band. (author) [French] A partir de l'equation de Vlasov nous calculons et discutons les equations de couplage non lineaire entre trois ondes plasma electroniques (ou ondes de Langmuir) qui se propagent dans une colonne de plasma cylindrique confinee par un champ magnetique de forte intensite. Nous etudions, dans le dispositif experimental EOS, le long du champ magnetique, la desintegration d'une onde de Langmuir excitee dans la colonne de plasma a l'aide d'une antenne. La mesure de la structure spatiale des differentes ondes montre que l'ensemble des conditions de resonance (ou regles de selection) sont satisfaites. Le seuil de desintegration mesure est en accord avec la valeur theorique a 30 pour cent pres et montre que ce mecanisme non lineaire apparait lorsque le rapport de la densite oscillante a la densite moyenne est de l'ordre de 10{sup -3} a 10{sup -2}. La variation du taux de croissance spatiale en fonction de l'amplitude de l'onde qui se desintegre montre que les ondes restent trois

  20. Theoretical and experimental study of a non-linear disintegration process for a langmuir wave; Etude theorique et experimental d'un processus non lineaire de desintegration d'une onde de langmuir

    Energy Technology Data Exchange (ETDEWEB)

    Perulli, M. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Using the Vlasov equation we calculate and discuss non-linear coupling equations between three electronic plasma waves (Langmuir waves) which propagate in a cylindrical plasma column confined by a strong magnetic field. We study, in the experimental device EOS, along the magnetic field, the disintegration of a Langmuir wave excited in the plasma column by means of an antenna. Space structure measurements for various waves show that the resonance conditions (selection rules) are satisfied. The measured disintegration threshold is in agreement with the theoretical value within 30 per cent and shows that this non linear mechanism appears when the oscillating density to the mean density ratio is about 10{sup -3} to 10{sup -2}. The variation of the spatial growth rate as a function of the amplitude of the disintegrated wave shows that the resulting waves are correlated in groups of three along the magnetic field even though the disintegrating spectrum appears in a wide frequency band. (author) [French] A partir de l'equation de Vlasov nous calculons et discutons les equations de couplage non lineaire entre trois ondes plasma electroniques (ou ondes de Langmuir) qui se propagent dans une colonne de plasma cylindrique confinee par un champ magnetique de forte intensite. Nous etudions, dans le dispositif experimental EOS, le long du champ magnetique, la desintegration d'une onde de Langmuir excitee dans la colonne de plasma a l'aide d'une antenne. La mesure de la structure spatiale des differentes ondes montre que l'ensemble des conditions de resonance (ou regles de selection) sont satisfaites. Le seuil de desintegration mesure est en accord avec la valeur theorique a 30 pour cent pres et montre que ce mecanisme non lineaire apparait lorsque le rapport de la densite oscillante a la densite moyenne est de l'ordre de 10{sup -3} a 10{sup -2}. La variation du taux de croissance spatiale en fonction de l'amplitude de l'onde qui se

  1. Cytogenetic investigation of subjects professionally exposed to radiofrequency radiation.

    Science.gov (United States)

    Maes, Annemarie; Van Gorp, Urbain; Verschaeve, Luc

    2006-03-01

    Nowadays, virtually everybody is exposed to radiofrequency radiation (RFR) from mobile phone base station antennas or other sources. At least according to some scientists, this exposure can have detrimental health effects. We investigated cytogenetic effects in peripheral blood lymphocytes from subjects who were professionally exposed to mobile phone electromagnetic fields in an attempt to demonstrate possible RFR-induced genetic effects. These subjects can be considered well suited for this purpose as their RFR exposure is 'normal' though rather high, and definitely higher than that of the 'general population'. The alkaline comet assay, sister chromatid exchange (SCE) and chromosome aberration tests revealed no evidence of RFR-induced genetic effects. Blood cells were also exposed to the well known chemical mutagen mitomycin C in order to investigate possible combined effects of RFR and the chemical. No cooperative action was found between the electromagnetic field exposure and the mutagen using either the comet assay or SCE test.

  2. Laparoscopic Ultrasound-Guided Radiofrequency Ablation of Uterine Fibroids

    International Nuclear Information System (INIS)

    Milic, Andrea; Asch, Murray R.; Hawrylyshyn, Peter A.; Allen, Lisa M.; Colgan, Terence J.; Kachura, John R.; Hayeems, Eran B.

    2006-01-01

    Four patients with symptomatic uterine fibroids measuring less than 6 cm underwent laparoscopic ultrasound-guided radiofrequency ablation (RFA) using multiprobe-array electrodes. Follow-up of the treated fibroids was performed with gadolinium-enhanced magnetic resonance imaging (MRI) and patients' symptoms were assessed by telephone interviews. The procedure was initially technically successful in 3 of the 4 patients and MRI studies at 1 month demonstrated complete fibroid ablation. Symptom improvement, including a decrease in menstrual bleeding and pain, was achieved in 2 patients at 3 months. At 7 months, 1 of these 2 patients experienced symptom worsening which correlated with recurrent fibroid on MRI. The third, initially technically successfully treated patient did not experience any symptom relief after the procedure and was ultimately diagnosed with adenomyosis. Our preliminary results suggest that RFA is a technically feasible treatment for symptomatic uterine fibroids in appropriately selected patients

  3. Radio-Frequency Applications for Food Processing and Safety.

    Science.gov (United States)

    Jiao, Yang; Tang, Juming; Wang, Yifen; Koral, Tony L

    2018-03-25

    Radio-frequency (RF) heating, as a thermal-processing technology, has been extending its applications in the food industry. Although RF has shown some unique advantages over conventional methods in industrial drying and frozen food thawing, more research is needed to make it applicable for food safety applications because of its complex heating mechanism. This review provides comprehensive information regarding RF-heating history, mechanism, fundamentals, and applications that have already been fully developed or are still under research. The application of mathematical modeling as a useful tool in RF food processing is also reviewed in detail. At the end of the review, we summarize the active research groups in the RF food thermal-processing field, and address the current problems that still need to be overcome.

  4. Electrode design for soil decontamination with Radio-Frequency heating

    Energy Technology Data Exchange (ETDEWEB)

    Roland, U.; Holzer, F.; Kraus, M.; Trommler, U.; Kopinke, F.D. [Helmholtz Centre for Environmental Research - UFZ, Department of Environmental Engineering, Leipzig (Germany)

    2011-10-15

    Radio-frequency heating to enhance soil decontamination requires adjusted solutions for the electrode design depending on scale and remediation technique. Parallel plate electrodes provide widely homogeneous field and temperature distributions and are, therefore, most suitable for supporting biodegradation processes. For thermally enhanced soil vapor extraction, certain temperature gradients can be accepted and, therefore, the less-demanding geometry of rod-shaped electrodes is usually applied. For electrode lengths of some meters, a design with an air gap has to be used in order to focus heating to the desired depth. Perforated rod electrodes may be simultaneously employed as extraction wells. Placing an oxidation catalyst in situ within the electrodes is an option for handling of highly loaded air flows. Coaxial antenna may be utilized to selectively heat soil compartments far from the surface of the soil. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Transport Characteristics of Mesoscopic Radio-Frequency Single Electron Transistor

    International Nuclear Information System (INIS)

    Phillips, A. H.; Kirah, K.; Aly, N. A. I.; El-Sayes, H. E.

    2008-01-01

    The transport property of a quantum dot under the influence of external time-dependent field is investigated. The mesoscopic device is modelled as semiconductor quantum dot coupled weakly to superconducting leads via asymmetric double tunnel barriers of different heights. An expression for the current is deduced by using the Landauer–Buttiker formula, taking into consideration of both the Coulomb blockade effect and the magnetic field. It is found that the periodic oscillation of the current with the magnetic field is controlled by the ratio of the frequency of the applied ac-field to the electron cyclotron frequency. Our results show that the present device operates as a radio-frequency single electron transistor

  6. Improved MR imaging in extremely inhomogenous radiofrequency fields

    International Nuclear Information System (INIS)

    Bansal, N.; Nunnally, R.L.

    1989-01-01

    A previous study developed a method for acquiring images in extremely inhomogeneous radio-frequency fields with use of adiabatic pulses. Since adiabatic pulses most suited to section selection are the inversion type, the method is prone to artifacts from receiver and analog-to-digital converter (ADC) saturation and subtraction errors. These problems are substantially reduced by using a pseudo-noise-modulated selective (PNMS) prepulse to randomize the unwanted spin magnetization. To compute the PNMS pulse shape, the frequency spectrum of a wave form with constant amplitude and random phase was determined by means of Fourier transformation and then inverted after a consecutive number of points were set to zero in the center. The performance of the prepulse with the imaging sequence was tested on a 1.8-T system. Results are presented

  7. SUPERCONDUCTING RADIO-FREQUENCY MODULES TEST FACILITY OPERATING EXPERIENCE

    International Nuclear Information System (INIS)

    Soyars, W.; Bossert, R.; Darve, C.; Degraff, B.; Klebaner, A.; Martinez, A.; Pei, L.; Theilacker, J.

    2008-01-01

    Fermilab is heavily engaged and making strong technical contributions to the superconducting radio-frequency research and development program (SRF R and D). Four major SRF test areas are being constructed to enable vertical and horizontal cavity testing, as well as cryomodule testing. The existing Fermilab cryogenic infrastructure has been modified to service the SRF R and D needs. The project's first stage has been successfully completed, which allows for distribution of cryogens for a single-cavity cryomodule using the existing Cryogenic Test Facility (CTF) that houses three Tevatron satellite refrigerators. The cooling capacity available for cryomodule testing at Meson Detector Building (MDB) results from the liquefaction capacity of the CTF cryogenic system. The cryogenic system for a single 9-cell cryomodule is currently operational. The paper describes the status, challenges and operational experience of the initial phase of the project

  8. Tumor Seeding Following Lung Radiofrequency Ablation: A Case Report

    International Nuclear Information System (INIS)

    Yamakado, Koichiro; Akeboshi, Masao; Nakatsuka, Atsuhiro; Takaki, Haruyuki; Takao, Motoshi; Kobayashi, Hiroyasu; Taguchi, Osamu; Takeda, Kan

    2005-01-01

    Lung radiofrequency (RF) ablation was performed for the treatment of a primary lung cancer measuring 2.5 cm in maximum diameter in a 78-year-old man. A contrast-enhanced computed tomography (CT) study performed 3 months after RF ablation showed incomplete ablation of the lung tumor and the appearance of a chest wall tumor 4.0 cm in maximum diameter that was considered to be the result of needle-tract seeding. RF ablation was performed for the treatment of both the lung and the chest wall tumors. Although tumor enhancement was eradicated in both of the treated tumors, follow-up CT studies revealed diffuse intra-pulmonary metastases in both lungs 2 months after the second RF session. He is currently receiving systemic chemotherapy

  9. Radio-frequency ion deflector for mass separation

    Energy Technology Data Exchange (ETDEWEB)

    Schlösser, Magnus, E-mail: magnus.schloesser@googlemail.com; Rudnev, Vitaly; Ureña, Ángel González, E-mail: laseres@pluri.ucm.es [Unidad de Láseres y Haces Moleculares, Instituto Plurisdisciplinar, Universidad Complutense de Madrid, Madrid 28040 (Spain)

    2015-10-15

    Electrostatic cylindrical deflectors act as energy analyzer for ion beams. In this article, we present that by imposing of a radio-frequency modulation on the deflecting electric field, the ion transmission becomes mass dependent. By the choice of the appropriate frequency, amplitude, and phase, the deflector can be used as mass filter. The basic concept of the new instrument as well as simple mathematic relations are described. These calculations and further numerical simulations show that a mass sensitivity is achievable. Furthermore, we demonstrate the proof-of-principle in experimental measurements, compare the results to those of from a 1 m linear time-of-flight spectrometer, and comment on the mass resolution of the method. Finally, some potential applications are indicated.

  10. Studies of Lear antiproton deceleration: radiofrequency quadripole or synchrotron

    International Nuclear Information System (INIS)

    Iazzourene, F.

    1987-06-01

    The aim of this work is to study a radiofrequency quadrupole (RFQ) and a synchrotron as decelerating systems for antiprotons extracted from the Low Energy Antiproton Ring (LEAR) at CERN. Antiprotons at energies lower than those available from LEAR are need by some experiments, eg. the measurement of the mass difference between protons and antiprotons with 10 -9 accuracy, using a Smith and Princeton spectrometer, and the measurement of gravitation on the antiprotons, using a trap. Depending on the LEAR performances, one can conclude that the RFQ is suitable for the experiment on the gravitation, and the synchrotron, owing to its electron cooling system, is a better solution for the experiment on the mass difference measurement, because of the very small acceptance of the spectrometer [fr

  11. The biophysics of renal sympathetic denervation using radiofrequency energy.

    Science.gov (United States)

    Patel, Hitesh C; Dhillon, Paramdeep S; Mahfoud, Felix; Lindsay, Alistair C; Hayward, Carl; Ernst, Sabine; Lyon, Alexander R; Rosen, Stuart D; di Mario, Carlo

    2014-05-01

    Renal sympathetic denervation is currently performed in the treatment of resistant hypertension by interventionists who otherwise do not typically use radiofrequency (RF) energy ablation in their clinical practice. Adequate RF lesion formation is dependent upon good electrode-tissue contact, power delivery, electrode-tissue interface temperature, target-tissue impedance and the size of the catheter's active electrode. There is significant interplay between these variables and hence an appreciation of the biophysical determinants of RF lesion formation is required to provide effective and safe clinical care to our patients. In this review article, we summarize the biophysics of RF ablation and explain why and how complications of renal sympathetic denervation may occur and discuss methods to minimise them.

  12. Radiofrequency protection guidelines and standards: basic concepts and principles

    International Nuclear Information System (INIS)

    Czerski, P.

    1985-01-01

    Over the past quarter of a century, radiofrequency radiation protection guidelines and standards evolved gradually and are continuously revised and refined. The scientific rationales presented for proposed exposure limits are achieving a considerable scientific sophistication. With increasing scientific validity of the presented arguments, the values of exposure limits are converging and one may hope that they will become convincing and acceptable to all schools of thought. Still more research is needed to refine the available exposure limits. This is recognized by ANSI who revise their recommendations periodically and are now engaged in the preparation of the next revision. INIRC/IRPA is also reconsidering their interim guideline. The Australian Standards Association also stressed the temporary nature of their exposure limits

  13. Automated radiofrequency radiation dosimetry. Final report, Jun 89-Sep 90

    Energy Technology Data Exchange (ETDEWEB)

    Gandhi, O.P.

    1990-12-01

    The interaction of radiofrequency (RF) and microwave (MW) electromagnetic radiation with biological tissues is of increasing importance from the standpoint of health and safety. From considerable literature devoted to the study of RF and MW bioeffects based primarily on animal experimentation it has been determined that bioeffects are correlated with mass-normalized rates of RF or MW energy absorption (specific absorption rates or SARs). An emphasis of our project was to improve the efficiency of the SAR algorithms and to extend their use to higher RF and MW frequencies. Another objective was to adapt these algorithms to computing workstations and distributed memory parallel processors that are becoming more affordable and hence readily available to potential users of these codes.

  14. Radiofrequency radiation exposure from RF-generating plant

    International Nuclear Information System (INIS)

    Wright, J.M.; Bell, K.M.

    2000-01-01

    As part of an intervention to assist industry improve the control of risks associated with the use of RF-generating plant, exposure to radiofrequency radiation (RFR) was assessed in 30 workplaces. Information about the workplace, work practices and knowledge about RFR and its control was also collected. The study found that: 1. For 72% of operators and 35% of bystanders, the spatially averaged exposure exceeded the exposure limits. These figures approximately halved when the duty cycle was applied; 2. Assessment of RFR levels was not common; 3. Task rotation was used to limit exposure of operators; 4. Access was not controlled to areas where RFR sources were used; 5. There was lack of knowledge about RF shielding practices in industry; 6. Nearly 50% of workplaces did not maintain the plant regularly; and 7. There had been no health surveillance on any plant operators in any of the workplaces in the study. Copyright (2000) Australasian Radiation Protection Society Inc

  15. Radiofrequency fields associated with the Itron smart meter.

    Science.gov (United States)

    Tell, R A; Sias, G G; Vazquez, A; Sahl, J; Turman, J P; Kavet, R I; Mezei, G

    2012-08-01

    This study examined radiofrequency (RF) emissions from smart electric power meters deployed in two service territories in California for the purpose of evaluating potential human exposure. These meters included transmitters operating in a local area mesh network (RF LAN, ∼250 mW); a cell relay, which uses a wireless wide area network (WWAN, ∼1 W); and a transmitter serving a home area network (HAN, ∼70 mW). In all instances, RF fields were found to comply by a wide margin with the RF exposure limits established by the US Federal Communications Commission. The study included specialised measurement techniques and reported the spatial distribution of the fields near the meters and their duty cycles (typically smart meters as deployed. However, the results are restricted to a single manufacturer's emitters.

  16. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain.

    Science.gov (United States)

    Biswas, Binay Kumar; Dey, Samarjit; Biswas, Saumya; Mohan, Varinder Kumar

    2016-01-01

    Sacroiliac (SI) joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF) neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] - 9/10) with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18 th -month follow-up, he is pain free except for mild pain (NRS 2/10) on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment.

  17. Percutaneous Radiofrequency Ablation for Treatment of Recurrent Retroperitoneal Liposarcoma

    International Nuclear Information System (INIS)

    Keil, Sebastian; Bruners, Philipp; Brehmer, Bernhard; Mahnken, Andreas Horst

    2008-01-01

    Percutaneous CT-guided radiofrequency ablation (RFA) is becoming more and more established in the treatment of various neoplasms, including retroperitoneal tumors of the kidneys and the adrenal glands. We report the case of RFA in a patient suffering from the third relapse of a retroperitoneal liposarcoma in the left psoas muscle. After repeated surgical resection and supportive radiation therapy of a primary retroperitoneal liposarcoma and two surgically treated recurrences, including replacement of the ureter by a fraction of the ileum, there was no option for further surgery. Thus, we considered RFA as the most suitable treatment option. Monopolar RFA was performed in a single session with a 2-cm umbrella-shaped LeVeen probe. During a 27-month follow-up period the patient remained free of tumor.

  18. Measurement of Radiofrequency Radiation Exposure in Epidemiological Studies (invited paper)

    International Nuclear Information System (INIS)

    Swerdlow, A.J.

    1999-01-01

    The measurement of radiofrequency (RF) exposure is important to the quality of epidemiological studies of the possible association of RF exposure with disease. The extent and type of exposure measurement in past epidemiological studies of RF, and the features of measurement that would be desirable for better studies in the future are summarised. Measurement characteristics that are discussed include quantification of radiation frequency and of intensity and timing of exposures, measurement (or good estimation) of exposures for individuals rather than only for groups, quality of measurement, and measurement of RF exposures experienced outside the study setting. Integration of exposure measurement into the design of epidemiological studies is needed for better assessments of possible RF effects. (author)

  19. Effect of the levitating microparticle cloud on radiofrequency argon plasma

    International Nuclear Information System (INIS)

    Mitic, S.; Pustylnik, M. Y.; Klumov, B. A.; Morfill, G. E.

    2010-01-01

    The effect of a levitating cloud of microparticles on the parameters of a radiofrequency (RF) plasma has been studied by means of two experimental techniques. Axial distributions of 1s excited states of argon were measured by a self-absorption method. A correction of a standard self-absorption method for the extinction of the light by the levitating microparticles is proposed. In addition the electron temperature was estimated using the optical emission spectroscopy. Measurements at the same discharge conditions in a microparticle-free discharge and discharge, containing a cloud of levitating microparticles, revealed the non-local influence of the microparticle cloud on the discharge plasma. The most probable cause of this influence is the disturbance of the ionization balance by the levitating microparticles.

  20. Assessment of occupational exposure to radiofrequency fields and radiation

    International Nuclear Information System (INIS)

    Cooper, T. G.; Allen, S. G.; Blackwell, R. P.; Litchfield, I.; Mann, S. M.; Pope, J. M.; Van Tongeren, M. J. A.

    2004-01-01

    The use of personal monitors for the assessment of exposure to radiofrequency fields and radiation in potential future epidemiological studies of occupationally exposed populations has been investigated. Data loggers have been developed for use with a commercially available personal monitor and these allowed personal exposure records consisting of time-tagged measurements of electric and magnetic field strength to be accrued over extended periods of the working day. The instrumentation was worn by workers carrying out tasks representative of some of their typical daily activities at a variety of radio sites. The results indicated significant differences in the exposures of workers in various RF environments. A number of measures of exposure have been examined with a view to assessing possible exposure metrics for epidemiological studies. There was generally a good correlation between a given measure of electric field strength and the same measure of magnetic field strength. (authors)

  1. Drone based measurement system for radiofrequency exposure assessment.

    Science.gov (United States)

    Joseph, Wout; Aerts, Sam; Vandenbossche, Matthias; Thielens, Arno; Martens, Luc

    2016-03-10

    For the first time, a method to assess radiofrequency (RF) electromagnetic field (EMF) exposure of the general public in real environments with a true free-space antenna system is presented. Using lightweight electronics and multiple antennas placed on a drone, it is possible to perform exposure measurements. This technique will enable researchers to measure three-dimensional RF-EMF exposure patterns accurately in the future and at locations currently difficult to access. A measurement procedure and appropriate measurement settings have been developed. As an application, outdoor measurements are performed as a function of height up to 60 m for Global System for Mobile Communications (GSM) 900 MHz base station exposure. Bioelectromagnetics. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Variable frequency matching to a radiofrequency source immersed in vacuum

    International Nuclear Information System (INIS)

    Charles, C; Boswell, R W; Bish, A

    2013-01-01

    A low-weight (0.12 kg) low-volume fixed ceramic capacitor impedance matching system is developed for frequency agile tuning of a radiofrequency (rf) Helicon plasma thruster. Three fixed groups of capacitors are directly mounted onto a two loop rf antenna with the thruster immersed in a vacuum chamber. Optimum plasma tuning at the resonance frequency is demonstrated via measurements of the load impedance, power transfer efficiency and plasma density versus driving frequency in the 12.882–14.238 MHz range. The resonance frequency with the plasma on is higher than the resonance frequency in vacuum. The minimum rf power necessary for ignition decreases when the ignition frequency is shifted downwards from the resonance frequency. This development has direct applications in space qualification and space use of rf plasma thrusters. (paper)

  3. Radiofrequency fields associated with the Itron smart meter

    International Nuclear Information System (INIS)

    Tell, R. A.; Sias, G. G.; Vazquez, A.; Sahl, J.; Turman, J. P.; Kavet, R. I.; Mezei, G.

    2008-01-01

    This study examined radiofrequency (RF) emissions from smart electric power meters deployed in two service territories in California for the purpose of evaluating potential human exposure. These meters included transmitters operating in a local area mesh network (RF LAN, ∼250 mW); a cell relay, which uses a wireless wide area network (WWAN, ∼1 W); and a transmitter serving a home area network (HAN, ∼70 mW). In all instances, RF fields were found to comply by a wide margin with the RF exposure limits established by the US Federal Communications Commission. The study included specialised measurement techniques and reported the spatial distribution of the fields near the meters and their duty cycles (typically <1 %) whose value is crucial to assessing time-averaged exposure levels. This study is the first to characterise smart meters as deployed. However, the results are restricted to a single manufacturer's emitters. (authors)

  4. A practical method to evaluate radiofrequency exposure of mast workers

    International Nuclear Information System (INIS)

    Alanko, T.; Hietanen, M.

    2008-01-01

    Assessment of occupational exposure to radiofrequency (RF) fields in telecommunication transmitter masts is a challenging task. For conventional field strength measurements using manually operated instruments, it is difficult to document the locations of measurements while climbing up a mast. Logging RF dosemeters worn by the workers, on the other hand, do not give any information about the location of the exposure. In this study, a practical method was developed and applied to assess mast workers' exposure to RF fields and the corresponding location. This method uses a logging dosemeter for personal RF exposure evaluation and two logging barometers to determine the corresponding height of the worker's position on the mast. The procedure is not intended to be used for compliance assessments, but to indicate locations where stricter assessments are needed. The applicability of the method is demonstrated by making measurements in a TV and radio transmitting mast. (authors)

  5. Flexible applicator systems for radiofrequency ablation (RFA) of hepatic tumors

    International Nuclear Information System (INIS)

    Gebauer, B.; Gaffke, G.; Felix, R.; Stroszczynski, C.; Huenerbein, M.

    2003-01-01

    Purpose: To report our experience with flexible applicators in radiofrequency ablation (RFA) of hepatic tumors. Materials and Methods: In 6 liver tumors in 6 patients, a flexible RFA-applicator system (RITA StarBurst FLEX, RITA Medical Systems, Mountain View, CA, USA) was placed under CT guidance. The Seldinger technique with an 11G access system (RITA StarBurst Access) was used to place the application system into the liver. Before and within a week after the ablation, all tumors were investigated with contrast-enhanced MRI. Results: The Seldinger technique accommodated the placement of a thin 17.5-gauge needle for the initial puncture, enabling easy adjustment of the position of the needle. The flexible applicator of the RFA system could be placed in 4.5 (±1.8) minutes on average. Conclusion: Flexible applicators facilitate CT-guided RFA and can be placed using the Seldinger technique. (orig.) [de

  6. Non-ablative skin tightening with radiofrequency in Asian skin.

    Science.gov (United States)

    Kushikata, Nobuharu; Negishi, Kei; Tezuka, Yukiko; Takeuchi, Kaori; Wakamatsu, Shingo

    2005-02-01

    The recent successful application of radiofrequency (RF) in non-ablative skin tightening for skin laxity has attracted attention worldwide. The efficacy and clinical effect of RF were assessed in Asian skin, with additional study on the duration of the effect and any complications. Eighty-five Japanese females were enrolled in the study for treatment of nasolabial folds, marionette lines, and sagging jowls with 6-month follow-up. RF treatment was effective for nasolabial folds, marionette lines, and jowls. Objective physician evaluation found relatively good improvement at 3 months post-treatment, and even better improvement at the 6-month evaluation. RF treatment was very satisfactory for skin tightening in Asian facial skin. When compared with published literature from the United States, the results suggested that there might be race-related differences in the treatment parameters. (c) 2005 Wiley-Liss, Inc.

  7. Stereotactic Radiofrequency Ablation for Metastatic Melanoma to the Liver

    Energy Technology Data Exchange (ETDEWEB)

    Bale, Reto, E-mail: reto.bale@i-med.ac.at; Schullian, Peter [Medical University Innsbruck, Department of Radiology, Section of Interventional Oncology - Microinvasive Therapy (SIP) (Austria); Schmuth, Matthias [Medical University Innsbruck, Department of Dermatology (Austria); Widmann, Gerlig; Jaschke, Werner [Medical University Innsbruck, Department of Radiology, Section of Interventional Oncology - Microinvasive Therapy (SIP) (Austria); Weinlich, Georg [Medical University Innsbruck, Department of Dermatology (Austria)

    2016-08-15

    PurposeTo evaluate the outcome of patients with melanoma liver metastasis treated with stereotactic radiofrequency ablation (SRFA).Material and MethodFollowing IRB approval, a retrospective evaluation of the treatment of 20 patients with 75 melanoma liver metastases was performed.ResultsA median number of 2 lesions (range 1–14) per patient with a median size of 1.7 cm (range 0.5–14.5 cm) were treated. 67 lesions were <3 cm (89.3 %) and 8 lesions were >3 cm (10.7 %). Per patient a median of 1 ablation session was performed (range: 1–4) totaling 34 sessions. There were no procedure-related deaths and all major complications (n = 3) could be easily treated by pleural drainages. The primary and secondary success rates were 89.3 and 93.3 %, respectively. The overall local recurrence rate was 13.3 %. Four of ten local recurrences were re-treated successfully by SRFA. During follow-up, 9/20 patients developed extrahepatic metastatic disease and 10/20 had liver recurrence at any location. The median OS from the date of SRFA was 19.3 months, with an OS of 64, 41, and 17 % at 1, 3, and 5 years, with no significant difference for patients with cutaneous and ocular melanoma. The median DFS after SRFA for all 20 patients was 9.5 months, with 37, 9, and 0 % at 1, 3, and 5 years.ConclusionsDue to the high local curative potential and the promising long-term survival rates associated with minimal morbidity and mortality, radiofrequency ablation seems to be an attractive alternative to resection in patients with melanoma liver metastases.

  8. Radiofrequency cold plasma nitrided carbon steel: Microstructural and micromechanical characterizations

    International Nuclear Information System (INIS)

    Bouanis, F.Z.; Bentiss, F.; Bellayer, S.; Vogt, J.B.; Jama, C.

    2011-01-01

    Highlights: → C38 carbon steel samples were plasma nitrided using a radiofrequency (rf) nitrogen plasma discharge. → RF plasma treatment enables nitriding for non-heated substrates. → The morphological and chemical analyses show the formation of a uniform thickness on the surface of the nitrided C38 steel. → Nitrogen plasma active species diffuse into the samples and lead to the formation of Fe x N. → The increase in microhardness values for nitrided samples with plasma processing time is interpreted by the formation of a thicker nitrided layer on the steel surface. - Abstract: In this work, C38 carbon steel was plasma nitrided using a radiofrequency (rf) nitrogen plasma discharge on non-heated substrates. General characterizations were performed to compare the chemical compositions, the microstructures and hardness of the untreated and plasma treated surfaces. The plasma nitriding was carried out on non-heated substrates at a pressure of 16.8 Pa, using N 2 gas. Surface characterizations before and after N 2 plasma treatment were performed by means of the electron probe microanalysis (EPMA), X-ray photoelectron spectroscopy (XPS) and Vickers microhardness measurements. The morphological and chemical analysis showed the formation of a uniform structure on the surface of the nitrided sample with enrichment in nitrogen when compared to untreated sample. The thickness of the nitride layer formed depends on the treatment time duration and is approximately 14 μm for 10 h of plasma treatment. XPS was employed to obtain chemical-state information of the plasma nitrided steel surfaces. The micromechanical results show that the surface microhardness increases as the plasma-processing time increases to reach, 1487 HV 0.005 at a plasma processing time of 8 h.

  9. Communication between functional and denervated muscles using radiofrequency.

    Science.gov (United States)

    Jacob, Doreen K; Stefko, Susan Tonya; Hackworth, Steven A; Lovell, Michael R; Mickle, Marlin H

    2006-05-01

    This article focuses on establishing communication between a functional muscle and a denervated muscle using a radiofrequency communications link. The ultimate objective of the project is to restore the eye blink in patients with facial nerve paralysis. Two sets of experiments were conducted using the gastrocnemius leg muscles of Sprague-Dawley rats. In the initial tests, varying magnitudes of voltages ranging from 0.85 to 2.5 V were applied directly to a denervated muscle to determine the voltage required to produce visible contraction. The second set of experiments was then conducted to determine the voltage output from an in vivo muscle contraction that could be sensed and used to coordinate a signal for actuation of a muscle in a separate limb. After designing the appropriate external communication circuitry, a third experiment was performed to verify that a signal between a functional and a denervated muscle can be generated and used as a stimulus. Voltages below 2 V at a 10-millisecond pulse width elicited a gentle, controlled contraction of the denervated muscle in vivo. It was also observed that with longer pulse widths, higher stimulation voltages were required to produce sufficient contractions. It is possible to detect contraction of a muscle, use this to generate a signal to an external base station, and subsequently cause a separate, denervated muscle to contract in response to the signal. This demonstration in vivo of a signaling system for pacing of electrical stimulation of 1 muscle to spontaneous contraction of another, separate muscle, using radiofrequency communication without direct connection, may be used in numerous ways to overcome nerve damage.

  10. Image-guided radiofrequency ablation (RFA) of spinal tumors

    International Nuclear Information System (INIS)

    Gevargez, Athour; Groenemeyer, Dietrich H.W.

    2008-01-01

    Purpose: To evaluate retrospectively the efficacy and safety of radiofrequency ablation (RFA) in patients with spinal tumors. Materials and methods: Forty-one patients (25 men, 16 women; age range, 46-82 years) with nonresectable primary or secondary tumor involvement of the spine unresponsive to chemo- and radiotherapy received RFA treatment. Two radiofrequency ablation systems, one with a cool-tip electrode and one with an expandable electrode catheter, were used. Both systems work impedance controlled with a power output of 150- 200 W. Each coagulation cycle lasted 12-15 min depending on tumor impedance. Several single RFA cycles of 15 min each were used for overlapping RFAs in tumors with diameters of more than 3 cm. Temperature was kept between 50 deg. C and 120 deg. C and was chosen according to spinal cord distance and patient heat tolerance during the ablation. Multi-slice computed tomography (CT) combined with C-arm fluoroscopy guided the intervention. Efficacy outcomes were assessed after about 6 weeks, 6 months, and more than 6 months using standardized questionnaires and indices regarding tumor pain, pain disability, functional activities, quality of life, neurological status, and tumor progression. Results: RFA significantly reduced tumor-induced pain within 6 weeks, improved daily activities, and maintained quality of life. Mean time to tumor progression was 730 ± 54 days (Kaplan-Meier estimate). No RFA-associated complications were reported. Conclusion: RFA of primary and secondary spinal tumors, which were unresponsive to chemo- and radiotherapy and prone to progression, is a safe, resource-saving, and highly effective percutaneous technique in patients with nonresectable spinal tumors

  11. Radiofrequency ablation of neuroendocrine liver metastases: the Middlesex experience.

    Science.gov (United States)

    Gillams, A; Cassoni, A; Conway, G; Lees, W

    2005-01-01

    Current treatment options for neuroendocrine liver metastases are not widely applicable or not that effective. Image-guided thermal ablation offers the possibility of a minimally invasive, albeit palliative, treatment that decreases tumor volume, preserves most of the normal liver, and can be repeated several times. We report our experience with image-guided thermal ablation in 25 patients with unresectable liver metastases. Since 1990 we have treated 189 tumors at 66 treatment sessions in 25 patients (12 female, 13 male; median age, 56 years; age range, 26--78 years). Thirty treatments were performed with a solid-state laser, and 36 treatments were performed with radiofrequency ablation. All but one treatment was performed percutaneously under image guidance. Sixteen patients had metastases from carcinoid primaries, three from gastrinoma, two from insulinoma, and four from miscellaneous causes. Fourteen of 25 had symptoms from hormone secretion. Imaging follow-up was available in 19 patients at a median of 21 months (range, 4--75 months). There was a complete response in six patients, a partial response in seven, and stable disease in one; hence, tumor load was controlled in 14 of 19 patients (74%). Relief of hormone-related symptoms was achieved in nine of 14 patients (69%). The median survival period from the diagnosis of liver metastases was 53 months. One patient with end-stage cardiac disease died after a carcinoid crisis. There were eight (12%) complications: five local and three distant, four major and four minor. As a minimally invasive, readily repeatable procedure that can be used to ablate small tumors, preferably before patients become severely symptomatic, radiofrequency ablation can provide effective control of liver tumor volume in most patients over many years.

  12. Factors Limiting Complete Tumor Ablation by Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Paulet, Erwan; Aube, Christophe; Pessaux, Patrick; Lebigot, Jerome; Lhermitte, Emilie; Oberti, Frederic; Ponthieux, Anne; Cales, Paul; Ridereau-Zins, Catherine; Pereira, Philippe L.

    2008-01-01

    The purpose of this study was to determine radiological or physical factors to predict the risk of residual mass or local recurrence of primary and secondary hepatic tumors treated by radiofrequency ablation (RFA). Eighty-two patients, with 146 lesions (80 hepatocellular carcinomas, 66 metastases), were treated by RFA. Morphological parameters of the lesions included size, location, number, ultrasound echogenicity, computed tomography density, and magnetic resonance signal intensity were obtained before and after treatment. Parameters of the generator were recorded during radiofrequency application. The recurrence-free group was statistically compared to the recurrence and residual mass groups on all these parameters. Twenty residual masses were detected. Twenty-nine lesions recurred after a mean follow-up of 18 months. Size was a predictive parameter. Patients' sex and age and the echogenicity and density of lesions were significantly different for the recurrence and residual mass groups compared to the recurrence-free group (p < 0.05). The presence of an enhanced ring on the magnetic resonance control was more frequent in the recurrence and residual mass groups. In the group of patients with residual lesions, analysis of physical parameters showed a significant increase (p < 0.05) in the time necessary for the temperature to rise. In conclusion, this study confirms risk factors of recurrence such as the size of the tumor and emphasizes other factors such as a posttreatment enhanced ring and an increase in the time necessary for the rise in temperature. These factors should be taken into consideration when performing RFA and during follow-up

  13. Radiofrequency energy exposure from the Trilliant smart meter.

    Science.gov (United States)

    Foster, Kenneth R; Tell, Richard A

    2013-08-01

    This paper reviews radiofrequency (RF) field levels produced by electric utility meters equipped with RF transceivers (so-called Smart Meters), focusing on meters from one manufacturer (Trilliant, Redwood City, CA, USA, and Granby, QC, Canada). The RF transmission levels are summarized based on publicly available data submitted to the U.S. Federal Communications Commission supplemented by limited independent measurements. As with other Smart Meters, this meter incorporates a low powered radiofrequency transceiver used for a neighborhood mesh network, in the present case using ZigBee-compliant physical and medium access layers, operating in the 2.45 GHz unlicensed band but with a proprietary network architecture. Simple calculations based on a free space propagation model indicate that peak RF field intensities are in the range of 10 mW m or less at a distance of more than 1-2 m from the meters. However, the duty cycle of transmission from the meters is very low (meter that were consistent with data reported by the vendor to the U.S. Federal Communications Commission. Limited measurements conducted in two houses with the meters were unable to clearly distinguish emissions from the meters from the considerable electromagnetic clutter in the same frequency range from other sources, including Wi-Fi routers and, when it was activated, a microwave oven. These preliminary measurements disclosed the difficulties that would be encountered in characterizing the RF exposures from these meters in homes in the face of background signals from other household devices in the same frequency range. An appendix provides an introduction to Smart Meter technology. The RF transmitters in wireless-equipped Smart Meters operate at similar power levels and in similar frequency ranges as many other digital communications devices in common use, and their exposure levels are very far below U.S. and international exposure limits.

  14. Radiofrequency cold plasma nitrided carbon steel: Microstructural and micromechanical characterizations

    Energy Technology Data Exchange (ETDEWEB)

    Bouanis, F.Z. [Universite Lille Nord de France, F-59000 Lille (France); Unite Materiaux et Transformations (UMET), Ingenierie des Systemes Polymeres, CNRS UMR 8207, ENSCL, BP 90108, F-59652 Villeneuve d' Ascq Cedex (France); Bentiss, F. [Laboratoire de Chimie de Coordination et d' Analytique, Faculte des Sciences, Universite Chouaib Doukkali, B.P. 20, M-24000 El Jadida (Morocco); Bellayer, S.; Vogt, J.B. [Universite Lille Nord de France, F-59000 Lille (France); Unite Materiaux et Transformations (UMET), Ingenierie des Systemes Polymeres, CNRS UMR 8207, ENSCL, BP 90108, F-59652 Villeneuve d' Ascq Cedex (France); Jama, C., E-mail: charafeddine.jama@ensc-lille.fr [Universite Lille Nord de France, F-59000 Lille (France); Unite Materiaux et Transformations (UMET), Ingenierie des Systemes Polymeres, CNRS UMR 8207, ENSCL, BP 90108, F-59652 Villeneuve d' Ascq Cedex (France)

    2011-05-16

    Highlights: {yields} C38 carbon steel samples were plasma nitrided using a radiofrequency (rf) nitrogen plasma discharge. {yields} RF plasma treatment enables nitriding for non-heated substrates. {yields} The morphological and chemical analyses show the formation of a uniform thickness on the surface of the nitrided C38 steel. {yields} Nitrogen plasma active species diffuse into the samples and lead to the formation of Fe{sub x}N. {yields} The increase in microhardness values for nitrided samples with plasma processing time is interpreted by the formation of a thicker nitrided layer on the steel surface. - Abstract: In this work, C38 carbon steel was plasma nitrided using a radiofrequency (rf) nitrogen plasma discharge on non-heated substrates. General characterizations were performed to compare the chemical compositions, the microstructures and hardness of the untreated and plasma treated surfaces. The plasma nitriding was carried out on non-heated substrates at a pressure of 16.8 Pa, using N{sub 2} gas. Surface characterizations before and after N{sub 2} plasma treatment were performed by means of the electron probe microanalysis (EPMA), X-ray photoelectron spectroscopy (XPS) and Vickers microhardness measurements. The morphological and chemical analysis showed the formation of a uniform structure on the surface of the nitrided sample with enrichment in nitrogen when compared to untreated sample. The thickness of the nitride layer formed depends on the treatment time duration and is approximately 14 {mu}m for 10 h of plasma treatment. XPS was employed to obtain chemical-state information of the plasma nitrided steel surfaces. The micromechanical results show that the surface microhardness increases as the plasma-processing time increases to reach, 1487 HV{sub 0.005} at a plasma processing time of 8 h.

  15. Radiofrequency electromagnetic fields in the Cookridge area of Leeds

    International Nuclear Information System (INIS)

    Fuller, K.; Gulson, A.D.; Judd, P.M.; Lowe, A.J.; Shaw, J.

    2002-01-01

    On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency electromagnetic fields in the environment such as broadcast radio and television transmissions are included in this range. Measurements of power density were made at eight locations in the vicinity of the transmitter sites. Comparison of the measurements with the guidelines showed that the total exposure from radio signals measured between 30 MHz and 18 GHz ranged from 0.26 millionths (0.000026%) to 190 millionths (0.019%) of the NRPB investigation level and from 1.6 millionths (0.00016%) to 1400 millionths (0.14%) of the ICNIRP reference level for exposure of the general public. All the measured exposures are therefore many times below guideline levels and are not considered hazardous. (author)

  16. Use of Semiflexible Applicators for Radiofrequency Ablation of Liver Tumors

    International Nuclear Information System (INIS)

    Gaffke, G.; Gebauer, B.; Knollmann, F.D.; Helmberger, T.; Ricke, J.; Oettle, H.; Felix, R.; Stroszczynski, C.

    2006-01-01

    Purpose. To evaluate the feasibility and potential advantages of the radiofrequency ablation of liver tumors using new MRI-compatible semiflexible applicators in a closed-bore high-field MRI scanner. Methods. We treated 8 patients with 12 malignant liver tumors of different origin (5 colorectal carcinoma, 2 cholangiocellular carcinoma, 1 breast cancer) under MRI guidance. Radiofrequency ablation (RFA) was performed using 5 cm Rita Starburst Semi-Flex applicators (Rita Medical Systems, Milwaukee, WI, USA) which are suitable for MR- and CT-guided interventions and a 150 W RF generator. All interventions were performed in a closed-bore 1.5 T high-field MRI scanner for MRI-guided RFA using fast T1-weighted gradient echo sequences and T2-weighted ultra-turbo spin echo sequences. Control and follow-up MRI examinations were performed on the next day, at 6 weeks, and every 3 months after RFA. Control MRI were performed as double-contrast MRI examinations (enhancement with iron oxide and gadopentetate dimeglumine). All interventions were performed with the patient under local anesthesia and analgo-sedation. Results. The mean diameter of the treated hepatic tumors was 2.4 cm (±0.6 cm, range 1.0-3.2 cm). The mean diameter of induced necrosis was 3.1 cm (±0.4 cm). We achieved complete ablation in all patients. Follow-up examinations over a duration of 7 months (±1.3 months, range 4-9 month) showed a local control rate of 100% in this group of patients. All interventions were performed without major complications; only 2 subcapsular hematomas were documented. Conclusion. RFA of liver tumors using semiflexible applicators in closed-bore 1.5 T scanner systems is feasible. These applicators might simplify the RFA of liver tumors under MRI control. The stiff distal part of the applicator facilitates its repositioning

  17. Comparison of Radiofrequency and Electrocautery With Conventional Scalpel Incisions.

    Science.gov (United States)

    Hasar, Zafer Burak; Ozmeric, Nurdan; Ozdemir, Burcu; Gökmenoğlu, Ceren; Baris, Emre; Altan, Gökçen; Kahraman, Sevil

    2016-11-01

    The disadvantages of conventional scalpels, including insufficient control of bleeding, prompted us to search for new alternative methods such as electrosurgery and radiosurgery. In this study, the conventional scalpel was compared with radiosurgery and electrosurgery for wound healing with assessment of lateral heat production, inflammation, and instrument performance. Incisions were made in the palatal mucosa of 42 Wistar rats using a scalpel, electrocautery instrument, or radiofrequency instrument. Postoperative hemostasis, tissue coagulation, and tissue sticking were measured, and pain evaluation through weight loss was recorded. Gingival biopsy specimens from the surgical area were obtained at the time of surgery and 2, 4, 7, and 14 days postoperatively and were evaluated immunohistochemically for inducible nitric oxide synthase and heat shock protein 70. Kruskal-Wallis, 1-way analysis of variance, and Mann-Whitney U tests were used for statistical evaluation. The rats in the electrosurgery and radiosurgery groups had aggressively greater weight loss when compared with the scalpel group in the first 7 days. Hemostasis was better in the electrocautery group, tissue coagulation was greater in the radiofrequency group (P < .001), and tissue sticking was lesser in the scalpel group (P < .001) compared with the other groups. Inducible nitric oxide synthase expression and heat shock protein 70 expression were similar in all 3 groups. Electrosurgery performed better regarding hemostasis, whereas a scalpel was superior in terms of tissue sticking and tissue coagulation. Radiosurgery was superior regarding hemostasis when compared with a conventional scalpel, but it was not as successful as electrosurgery. Copyright © 2016. Published by Elsevier Inc.

  18. Radiofrequency (thermal) ablation versus no intervention or other interventions for hepatocellular carcinoma

    DEFF Research Database (Denmark)

    Weis, Sebastian; Franke, Annegret; Mössner, Joachim

    2013-01-01

    Hepatocellular carcinoma is the fifth most common cancer worldwide. Percutaneous interventional therapies, such as radiofrequency (thermal) ablation (RFA), have been developed for early hepatocellular carcinoma. RFA competes with other interventional techniques such as percutaneous ethanol...

  19. Temporal changes in patient characteristics and prior pharmacotherapy in patients undergoing radiofrequency ablation of atrial fibrillation

    DEFF Research Database (Denmark)

    Karasoy, Deniz; Gislason, Gunnar Hilmar; Hansen, Jim

    2013-01-01

    Trends in patient selection and pharmacotherapy before radiofrequency ablation (RFA) of atrial fibrillation are not well studied. We examined temporal trends in RFA utilization on a nationwide scale in Denmark....

  20. Investigation of beech wood modified by radio-frequency discharge plasma

    Czech Academy of Sciences Publication Activity Database

    Novák, I.; Popelka, A.; Špitalský, Z.; Mičušík, M.; Omastová, M.; Valentin, M.; Sedliačik, J.; Janigová, I.; Kleinová, A.; Šlouf, Miroslav

    2015-01-01

    Roč. 119, September (2015), s. 88-94 ISSN 0042-207X Institutional support: RVO:61389013 Keywords : radio-frequency plasma * beech wood * adhesive properties Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.558, year: 2015

  1. Radio-frequency transparent demodulation for broadband hybrid wireless-optical links

    DEFF Research Database (Denmark)

    Zibar, Darko; Sambaraju, Rakesh; Alemany, Ruben

    2010-01-01

    A novel demodulation technique which is transparent to radio-frequency (RF) carrier frequency is presented and experimentally demonstrated for multigigabit wireless signals. The presented demodulation technique employs optical single-sideband filtering, coherent detection, and baseband digital si...

  2. Poloidally asymmetric potential increases in tokamak scrape-off layer plasmas by radiofrequency power

    International Nuclear Information System (INIS)

    Diebold, D.A.; Majeski, R.; Tanaka, T.

    1992-01-01

    Langmuir probe data are presented which show poloidally asymmetric increases in floating potential, electron temperature and, hence, plasma potential on magnetic field lines which map to the Faraday shield of an ICRF antenna in a medium size tokamak, Phaedrus-T, during radiofrequency power injection. These data are consistent with and suggestive of the existence of radiofrequency generated sheath voltages on those field lines. (author). Letter-to-the-editor. 20 refs, 3 figs

  3. 12-month efficacy of a single radiofrequency ablation on autonomously functioning thyroid nodules.

    Science.gov (United States)

    Bernardi, Stella; Stacul, Fulvio; Michelli, Andrea; Giudici, Fabiola; Zuolo, Giulia; de Manzini, Nicolò; Dobrinja, Chiara; Zanconati, Fabrizio; Fabris, Bruno

    2017-09-01

    Radiofrequency ablation has been advocated as an alternative to radioiodine and/or surgery for the treatment of autonomously functioning benign thyroid nodules. However, only a few studies have measured radiofrequency ablation efficacy on autonomously functioning benign thyroid nodules. The aim of this work was to evaluate the 12-month efficacy of a single session of radiofrequency ablation (performed with the moving shot technique) on solitary autonomously functioning benign thyroid nodules. Thirty patients with a single, benign autonomously functioning benign thyroid nodules, who were either unwilling or ineligible to undergo surgery and radioiodine, were treated with radiofrequency ablation between April 2012 and May 2015. All the patients underwent a single radiofrequency ablation, performed with the 18-gauge needle and the moving shot technique. Clinical, laboratory, and ultrasound evaluations were scheduled at baseline, and after 1, 3, 6, and 12 months from the procedure. A single radiofrequency ablation reduced thyroid nodule volume by 51, 63, 69, and 75 % after 1, 3, 6, and 12 months, respectively. This was associated with a significant improvement of local cervical discomfort and cosmetic score. As for thyroid function, 33 % of the patients went into remission after 3 months, 43 % after 6 months, and 50 % after 12 months from the procedure. This study demonstrates that a single radiofrequency ablation allowed us to withdraw anti-thyroid medication in 50 % of the patients, who remained euthyroid afterwards. This study shows that a single radiofrequency ablation was effective in 50 % of patients with autonomously functioning benign thyroid nodules. Patients responded gradually to the treatment. It is possible that longer follow-up studies might show greater response rates.

  4. The Precautionary Principle in the Context of Mobile Phone and Base Station Radiofrequency Exposures

    OpenAIRE

    Dolan, Mike; Rowley, Jack

    2009-01-01

    Background No health hazard has been established from exposure to radiofrequency fields up to the levels recommended by the International Commission on Non-Ionizing Radiation Protection. However, in response to public concern and the perceived level of scientific uncertainty, there are continuing calls for the application of the precautionary principle to radiofrequency exposures from mobile phones and base stations. Objective We examined the international evolution of calls for precautionary...

  5. Explanation for Cancer in Rats, Mice and Humans due to Cell Phone Radiofrequency Radiation

    OpenAIRE

    Feldman, Bernard J.

    2016-01-01

    Very recently, the National Toxicology Program reported a correlation between exposure to whole body 900 MHz radiofrequency radiation and cancer in the brains and hearts of Sprague Dawley male rats. This paper proposes the following explanation for these results. The neurons around the rat's brain and heart form closed electrical circuits and, following Faraday's Law, 900 MHz radiofrequency radiation induces 900 MHz electrical currents in these neural circuits. In turn, these 900 MHz currents...

  6. Papillary thyroid carcinoma treated with radiofrequency ablation in a patient with hypertrophic cardiomyopathy: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Jian Yi; Liu, Xiao Sun; Zhang, Qing; Hong, Yan Yun; Song, Bin; Teng, Xiao Dong; Yu, Ji Ren [The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou (China)

    2016-07-15

    Standard therapy has not been established for thyroid cancer when a thyroidectomy is contraindicated due to systemic disease. Herein, we reported a patient who had hypertrophic cardiomyopathy and papillary thyroid carcinoma treated by radiofrequency ablation because of inability to tolerate a thyroidectomy. Radiofrequency ablation can be used to treat thyroid cancer when surgery is not feasible, although the long-term outcome needs further observation.

  7. Papillary Thyroid Carcinoma Treated with Radiofrequency Ablation in a Patient with Hypertrophic Cardiomyopathy: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Jianyi; Liu, Xiaosun; Zhang, Qing; Hong, Yanyun; Song, Bin [Department of Gastrointestinal and Thyroid Surgery, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China); Teng, Xiaodong [Department of Pathology, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China); Yu, Jiren [Department of Gastrointestinal and Thyroid Surgery, The First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003 (China)

    2016-11-01

    Standard therapy has not been established for thyroid cancer when a thyroidectomy is contraindicated due to systemic disease. Herein, we reported a patient who had hypertrophic cardiomyopathy and papillary thyroid carcinoma treated by radiofrequency ablation because of inability to tolerate a thyroidectomy. Radiofrequency ablation can be used to treat thyroid cancer when surgery is not feasible, although the long-term outcome needs further observation.

  8. The Biological Effects of Quadripolar Radiofrequency Sequential Application: A Human Experimental Study

    OpenAIRE

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-01-01

    Objective: An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Background data: Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. Methods: The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radio...

  9. Non-destructive radio-frequency and microwave measurement of moisture content in agricultural commodities

    International Nuclear Information System (INIS)

    Nelson, S.O.

    1994-01-01

    The importance of moisture content in agricultural commodities, the usefulness of the dielectric properties of such products for sensing moisture content by radiofrequency and microwave measurements, and factors affecting these properties are briefly discussed. Recent developments in the understanding of principles for online moisture sensing and the sensing of individual kernel, seed, nut and fruit moisture contents by radiofrequency and microwave techniques are reviewed. A brief discussion is included on aspects of practical application

  10. Perivascular radiofrequency renal denervation lowers blood pressure and ameliorates cardiorenal fibrosis in spontaneously hypertensive rats

    Science.gov (United States)

    Zhang, Yan; Su, Linan; Zhang, Yunrong; Wang, Qiang; Yang, Dachun; Li, De; Yang, Yongjian; Ma, Shuangtao

    2017-01-01

    Background Catheter-based renal denervation (RDN) is a promising approach to treat hypertension, but innervation patterns limit the response to endovascular RDN and the post-procedural renal artery narrowing or stenosis questions the endovascular ablation strategy. This study was performed to investigate the anti-hypertensive and target organ protective effects of perivascular RDN in spontaneously hypertensive rats (SHR). Methods SHR and normotensive Wistar-Kyoto (WKY) rats were divided into sham group (n = 10), radiofrequency ablation group (n = 20) in which rats received bilateral perivascular ablation with radiofrequency energy (2 watts), and chemical (10% phenol in 95% ethanol) ablation group (n = 12). The tail-cuff blood pressure was measured before the ablation and on day 14 and day 28 after the procedure. The plasma levels of creatinine, urea nitrogen, and catecholamines, urinary excretion of electrolytes and protein, and myocardial and glomerular fibrosis were analyzed and compared among the groups on day 28 after the procedure. Results We identified that 2-watt is the optimal radiofrequency power for perivascular RDN in rats. Perivascular radiofrequency and chemical ablation achieved roughly comparable blood pressure reduction in SHR but not in WKY on day 14 and day 28 following the procedure. Radiofrequency-mediated ablation substantially destroyed the renal nerves surrounding the renal arteries of both SHR and WKY without damaging the renal arteries and diminished the expression of tyrosine hydroxylase, the enzyme marker for postganglionic sympathetic nerves. Additionally, perivascular radiofrequency ablation also decreased the plasma catecholamines of SHR. Interestingly, both radiofrequency and chemical ablation decreased the myocardial and glomerular fibrosis of SHR, while neither increased the plasma creatinine and blood urea nitrogen nor affected the urinary excretion of electrolytes and protein when compared to sham group. Conclusions Radiofrequency

  11. Use of Radiofrequency Ablation in Benign Thyroid Nodules: A Literature Review and Updates

    OpenAIRE

    Wong, KP; Lang, HHB

    2013-01-01

    Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA) has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid...

  12. Les métamatériaux, des micro-ondes à l'optique : théorie et applications

    Science.gov (United States)

    Kante, B.

    2010-04-01

    Cet article constitue une contribution originale et importante à la compréhension à la fois théorique et expérimentale des métamatériaux en micro-ondes et en infrarouge. Nous avons réalisé et caractérisé sur silicium des nano-structures metallo-diélectriques, briques de base des métamatériaux infrarouge et optique. Des caractérisations optiques exhaustives ont été réalisées pour la première fois sur ces structures en amplitude et en phase par interférométrie. Des topologies plus simples de métamatériaux d’un point de vue technologique et des performances optiques ont été introduites, et leur potentiel démontré dans la réalisation de fonctions aussi complexes que la réfraction négative, le couplage de mode plasmoniques, les nano senseurs pour la biologie et l’invisibilité électromagnétique en infrarouge. Les transformations d’espace, et le nouveau paradigme qu’elles offrent à l’optique, rendant possible une ingénierie de l’espace pour les photons ainsi que leur implémentation par métamatériaux ont été présentés par la première démonstration expérimentale d’une cape d’invisibilité non magnétique.

  13. Improvements in the electromechanical conversion of energy using shock waves; Contribution a la conversion d'energie electromecanique par onde de choc

    Energy Technology Data Exchange (ETDEWEB)

    Landure, Yves

    1971-10-21

    This report concerns the electrical mechanical conversion. In this study it was obtained by the depolarization of a ferroelectric ceramic. We are particularly interested by the high electrical horse-power. Shock wave which produces depolarization is created by a gun powder. The speed of the projectile is measured and the pressures generated in the ceramic is determined graphically. The energy freed is released on a linear resistive load. We were able to prove by different parameters how to obtain the maximum electrical energy. On a resistive load of 26 ohms, it was freed 0,91 J/cm{sup 3} in less than 0,5 μs corresponding to an electrical horse-power superior to 2 MW/cm{sup 3}. (author) [French] Ce rapport concerne la conversion d'energie electro-mecanique. Dans cette etude elle est obtenue par la depolarisation d'une ceramique ferro-electrique. Nous nous sommes interesses tout particulierement aux fortes puissances. L'onde de pression produisant la depolarisation est creee par l'impact d'un projectile lance par un canon a poudre. La vitesse du projectile est mesuree et la pression engendree dans la ceramique est determinee graphiquement. L'energie liberee est recueillie sur une impedance de charge lineaire. On a pu mettre en evidence differents parametres permettant d'obtenir l'energie electrique maximale. Sur une charge resistive de 26 ohms, il a ete libere 0,91 j/cm{sup 3} en moins de 0,5 μs, soit une puissance superieure a 2 MW/cm{sup 3}. (auteur)

  14. Knee cooled radiofrequency vs continuous radiofrequency for genicular neurotomy: preliminary experience - Crio-radiofrequenza vs radiofrequenza continua per neurotomia dei nervi genicolati: esperienza preliminare

    Directory of Open Access Journals (Sweden)

    Alfonso Papa

    2016-09-01

    Full Text Available Radiofrequency neurotomy of genicular nerves has been often used as an efficacious treatment option in all patients suffering from chronic osteoarthritis pain to provide long-term pain relief. After providing informed written consent, 80 patients with severe knee chronic osteoarthritis pain had been enrolled; patients had been divided into two groups (Group C, crioneurolysis, vs Group R, traditional radiofrequency, 40 patients for each group. Pain relief in C group was poorer and with shorter time in duration (median NRS reducing from 8 to 5. Radiofrequency can be considered as an effective, minimally invasive treat­ment for these kinds of conditions, and offers the benefit of being a fast procedure with long-term pain relief.

  15. The safety and efficacy of a combined diode laser and bipolar radiofrequency compared with combined infrared light and bipolar radiofrequency for skin rejuvenation.

    Science.gov (United States)

    Choi, Yeon Jin; Lee, Jung Yeon; Ahn, Ji Young; Kim, Myeung Nam; Park, Mi Youn

    2012-01-01

    As the demand for noninvasive procedures for skin rejuvenation is increasing, combined diode laser and radiofrequency and combined infrared and radiofrequency devices have recently emerged. To compare Polaris WRA(TM), a combination device of diode light and RF, and ReFirme ST(TM), a combination device of infrared and bipolar RF, in terms of safety and efficacy on skin rejuvenation. Fourteen Korean volunteers of skin type II-IV, with facial laxity and periorbital rhytids, received three treatments at 3-week intervals with combined diode laser and bipolar radiofrequency (laser fluence 30 J/cm2, RF fluence 90 J/cm3) on the right half of their faces and combined infrared light and bipolar radiofrequency (RF fluence 120 J/cm3) on the left half of their faces. Clinical photos of front and bilateral sides of the subjects' faces were taken at baseline and at 6, 9, 12 weeks after the treatment initiation. The investigators' and the subjects' global assessments were performed. There is no statistically significant difference in the overall outcome between Polaris WRA(TM) and Refirme ST(TM) based on pre- and post-treatment objective measurements. Polaris WRA(TM) was more effective than Refirme ST(TM) at reducing wrinkles when therapeutic results of the two appliances were compared based on the patient satisfaction measurements. After the treatment with both instruments, histological increase in the production and rearrangement of collagen fibers at the dermal layer was observed. The density of the collagen fibers was more increased with the Polaris WRA(TM)-treated facial area than that of Refirme ST(TM). Treatment was generally well tolerated, and there was no serious complication. In this study, both the lasers appeared to be safe, and effective methods for treating skin laxity and facial wrinkles. Combined diode laser and radiofrequency was more effective than combined infrared and radiofrequency at reducing wrinkles and pores when the therapeutic results of both the

  16. The safety and efficacy of a combined diode laser and bipolar radiofrequency compared with combined infrared light and bipolar radiofrequency for skin rejuvenation

    Directory of Open Access Journals (Sweden)

    Yeon Jin Choi

    2012-01-01

    Full Text Available Background: As the demand for noninvasive procedures for skin rejuvenation is increasing, combined diode laser and radiofrequency and combined infrared and radiofrequency devices have recently emerged. Aim: To compare Polaris WRA TM , a combination device of diode light and RF, and ReFirme ST TM , a combination device of infrared and bipolar RF, in terms of safety and efficacy on skin rejuvenation. Methods: Fourteen Korean volunteers of skin type II-IV, with facial laxity and periorbital rhytids, received three treatments at 3-week intervals with combined diode laser and bipolar radiofrequency (laser fluence 30 J/cm 2 , RF fluence 90 J/cm 3 on the right half of their faces and combined infrared light and bipolar radiofrequency (RF fluence 120 J/cm 3 on the left half of their faces. Clinical photos of front and bilateral sides of the subjects′ faces were taken at baseline and at 6, 9, 12 weeks after the treatment initiation. The investigators′ and the subjects′ global assessments were performed. Results: There is no statistically significant difference in the overall outcome between Polaris WRA TM and Refirme ST TM based on pre- and post-treatment objective measurements. Polaris WRA TM was more effective than Refirme ST TM at reducing wrinkles when therapeutic results of the two appliances were compared based on the patient satisfaction measurements. After the treatment with both instruments, histological increase in the production and rearrangement of collagen fibers at the dermal layer was observed. The density of the collagen fibers was more increased with the Polaris WRA TM -treated facial area than that of Refirme ST TM . Treatment was generally well tolerated, and there was no serious complication. Conclusion: In this study, both the lasers appeared to be safe, and effective methods for treating skin laxity and facial wrinkles. Combined diode laser and radiofrequency was more effective than combined infrared and radiofrequency at

  17. Radiofrequency Denervation Improves Health-Related Quality of Life in Patients with Thoracic Zygapophyseal Joint Pain.

    Science.gov (United States)

    Hambraeus, Johan; Hambraeus, Kjerstin S; Persson, Jan

    2018-05-01

    To describe a practical approach for the diagnosis and treatment of thoracic zygapophyseal joint pain and to present preliminary clinical data on the effects of this treatment approach on health-related quality of life. An observational study. Specialist outpatient pain clinic in northern Sweden. Patients with long-term thoracic pain. We describe a method of radiofrequency denervation of thoracic zygapophyseal joints. We compared health-related quality of life between patients who underwent radiofrequency denervation of thoracic zygapophyseal joints and patients who underwent radiofrequency denervation for lumbar and cervical zygapophyseal joint pain. Treatment according to the Spine Intervention Society Guidelines was performed on the lumbar region in 178 patients and in the cervical region in 55 patients. Another 82 patients were treated in the thoracic region with our proposed technique. A survival plot of improvements in health-related quality of life revealed that all three treatments were effective in 65% or more of patients. The improvement in health-related quality of life was maintained for 12 or more months after treatment in 47% to 51% of patients. Our results suggest that radiofrequency denervation of thoracic zygapophyseal joint pain is as effective as radiofrequency denervation, the standard treatment, for lumbar and cervical zygapophyseal joint pain. If these results can be confirmed by other centers, radiofrequency denervation is likely to become more widely available for the treatment of thoracic zygapophyseal joint pain.

  18. Comparison of microbubble presence in the right heart during mechanochemical and radiofrequency ablation for varicose veins.

    Science.gov (United States)

    Moon, K H; Dharmarajah, B; Bootun, R; Lim, C S; Lane, Tra; Moore, H M; Sritharan, K; Davies, A H

    2017-07-01

    Objective Mechanochemical ablation is a novel technique for ablation of varicose veins utilising a rotating catheter and liquid sclerosant. Mechanochemical ablation and radiofrequency ablation have no reported neurological side-effect but the rotating mechanism of mechanochemical ablation may produce microbubbles. Air emboli have been implicated as a cause of cerebrovascular events during ultrasound-guided foam sclerotherapy and microbubbles in the heart during ultrasound-guided foam sclerotherapy have been demonstrated. This study investigated the presence of microbubbles in the right heart during varicose vein ablation by mechanochemical abaltion and radiofrequency abaltion. Methods Patients undergoing great saphenous vein ablation by mechanochemical abaltion or radiofrequency ablation were recruited. During the ablative procedure, the presence of microbubbles was assessed using transthoracic echocardiogram. Offline blinded image quantification was performed using International Consensus Criteria grading guidelines. Results From 32 recruited patients, 28 data sets were analysed. Eleven underwent mechanochemical abaltion and 17 underwent radiofrequency abaltion. There were no neurological complications. In total, 39% (11/28) of patients had grade 1 or 2 microbubbles detected. Thirty-six percent (4/11) of mechanochemical abaltion patients and 29% (5/17) of radiofrequency ablation patients had microbubbles with no significant difference between the groups ( p=0.8065). Conclusion A comparable prevalence of microbubbles between mechanochemical abaltion and radiofrequency ablation both of which are lower than that previously reported for ultrasound-guided foam sclerotherapy suggests that mechanochemical abaltion may not confer the same risk of neurological events as ultrasound-guided foam sclerotherapy for treatment of varicose veins.

  19. Intraarticular Pulsed Radiofrequency to Treat Refractory Lumbar Facet Joint Pain in Patients with Low Back Pain.

    Science.gov (United States)

    Chang, Min Cheol; Cho, Yun-Woo; Ahn, Da Hyun; Do, Kyung Hee

    2018-04-01

    Many treatment techniques have been used for refractory lumbar facet joint pain; however, their efficacy has been controversial. In this study, we investigated the clinical efficacy and safety of intra-articular pulsed radiofrequency for the treatment of refractory lumbar facet joint pain in patients with low back pain. Twenty patients with refractory lumbar facet joint pain were recruited, and each patient was treated via intra-articular pulsed radiofrequency. The treatment effects were measured with a numerical rating scale, and the technical accuracy of intra-articular pulsed radiofrequency treatment was evaluated independently by 2 radiologists. Any adverse events or complications also were checked. We performed intra-articular pulsed radiofrequency treatment at 48 levels of the lumbar facet joints in 20 patients (5 men and 15 women; mean age, 64.50 ± 10.65 years) with refractory lumbar facet joint pain. Pain scores were significantly reduced at 1 month, 3 months, and 6 months after treatment (P radiofrequency results in all 20 patients, without any serious adverse effects. Treatment using intra-articular pulsed radiofrequency is an alternative to other techniques in patients with refractory lumbar facet joint pain. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.

    Science.gov (United States)

    Mahfoud, Felix; Tunev, Stefan; Ruwart, Jennifer; Schulz-Jander, Daniel; Cremers, Bodo; Linz, Dominik; Zeller, Thomas; Bhatt, Deepak L; Rocha-Singh, Krishna; Böhm, Michael; Melder, Robert J

    2014-12-01

    In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA. We report marked blood pressure reduction after RDN in a patient with resistant hypertension who underwent previous stenting. Subsequently, radiofrequency ablation was investigated within the stented segment of porcine RA, distal to the stented segment, and in nonstented RA and compared with stent only and untreated controls. There were neither observations of thrombus nor gross or histological changes in the kidneys. After radiofrequency ablation of the nonstented RA, sympathetic nerves innervating the kidney were significantly reduced, as indicated by significant decreases in sympathetic terminal axons and reduction of norepinephrine in renal tissue. Similar denervation efficacy was found when RDN was performed distal to a renal stent. In contrast, when radiofrequency ablation was performed within the stented segment of the RA, significant sympathetic nerve ablation was not seen. Histological observation showed favorable healing in all arteries. Radiofrequency ablation of previously stented RA demonstrated that RDN provides equally safe experimental procedural outcomes in a porcine model whether the radiofrequency treatment is delivered within, adjacent, or without the stent struts being present in the RA. However, efficacious RDN is only achieved when radiofrequency ablation is delivered to the nonstented RA segment distal to the stent. © 2014 American Heart Association, Inc.

  1. La réflexion des ondes électromagnétiques du milieu de gyrotropie anisotrope, avec un axe d'anisotropie et un angle d'incidence arbitraires

    Science.gov (United States)

    Tchalyk, A.

    1994-01-01

    The interaction of plane electromagnetic wave with half-infinit gyrotropic media for different directions of propagation of incident microwave radiation and various directions of gyrotropic axis are investigated. The equations for calculation of wave's parameters exited in media and reflected from media-surface are obtained. On étudie l'interaction d'une onde électromagnétique plane avec un milieu gyrotrope à demi-infini dans le cas d'une direction arbitraire de propagation de la radiation électromagnétique incidente et de l'axe de gyrotropie. On a obtenu des expressions permettant de calculer les caractéristiques des ondes excitées dans et par le milieu.

  2. Diverse Radiofrequency Sensitivity and Radiofrequency Effects of Mobile or Cordless Phone near Fields Exposure in Drosophila melanogaster

    Science.gov (United States)

    Geronikolou, Styliani; Zimeras, Stelios; Davos, Constantinos H.; Michalopoulos, Ioannis; Tsitomeneas, Stephanos

    2014-01-01

    Introduction The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. Methods/Results Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations) and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. Conclusions/Significance Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects. PMID:25402465

  3. Diverse radiofrequency sensitivity and radiofrequency effects of mobile or cordless phone near fields exposure in Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Styliani Geronikolou

    Full Text Available INTRODUCTION: The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. METHODS/RESULTS: Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. CONCLUSIONS/SIGNIFICANCE: Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects.

  4. Diverse radiofrequency sensitivity and radiofrequency effects of mobile or cordless phone near fields exposure in Drosophila melanogaster.

    Science.gov (United States)

    Geronikolou, Styliani; Zimeras, Stelios; Davos, Constantinos H; Michalopoulos, Ioannis; Tsitomeneas, Stephanos

    2014-01-01

    The impact of electromagnetic fields on health is of increasing scientific interest. The aim of this study was to examine how the Drosophila melanogaster animal model is affected when exposed to portable or mobile phone fields. Two experiments have been designed and performed in the same laboratory conditions. Insect cultures were exposed to the near field of a 2G mobile phone (the GSM 2G networks support and complement in parallel the 3G wide band or in other words the transmission of information via voice signals is served by the 2G technology in both mobile phones generations) and a 1880 MHz cordless phone both digitally modulated by human voice. Comparison with advanced statistics of the egg laying of the second generation exposed and non-exposed cultures showed limited statistical significance for the cordless phone exposed culture and statistical significance for the 900 MHz exposed insects. We calculated by physics, simulated and illustrated in three dimensional figures the calculated near fields of radiation inside the experimenting vials and their difference. Comparison of the power of the two fields showed that the difference between them becomes null when the experimental cylinder radius and the height of the antenna increase. Our results suggest a possible radiofrequency sensitivity difference in insects which may be due to the distance from the antenna or to unexplored intimate factors. Comparing the near fields of the two frequencies bands, we see similar not identical geometry in length and height from the antenna and that lower frequencies tend to drive to increased radiofrequency effects.

  5. Phase and group refractive index curves for electromagnet waves moving in an ionised medium (1962); Courbes des indices de phase et de groupe d'ondes electromagnetiques se propageant dans un milieu ionise (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    The family of curves presented in this table give the phase and group refractive indexes of plane electromagnetic waves propagating along and across a static magnetic field in a plasma. (author) [French] Les courbes presentees sous formes de reseaux donnent les indices de phase et de groupe d'ondes electromagnetiques planes se propageant longitudinalement ou transversalement dans un plasma en presence d'un champ magnetique statique. (auteur)

  6. Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch

    Science.gov (United States)

    Nessel, James; Miranda, Felix

    2013-01-01

    A new nonvolatile nanoionic switch is powered and controlled through wireless radio-frequency (RF) transmission. A thin layer of chalcogenide glass doped with a metal ion, such as silver, comprises the operational portion of the switch. For the switch to function, an oxidizable electrode is made positive (anode) with respect to an opposing electrode (cathode) when sufficient bias, typically on the order of a few tenths of a volt or more, is applied. This action causes the metal ions to flow toward the cathode through a coordinated hopping mechanism. At the cathode, a reduction reaction occurs to form a metal deposit. This metal deposit creates a conductive path that bridges the gap between electrodes to turn the switch on. Once this conductive path is formed, no further power is required to maintain it. To reverse this process, the metal deposit is made positive with respect to the original oxidizable electrode, causing the dissolution of the metal bridge thereby turning the switch off. Once the metal deposit has been completely dissolved, the process self-terminates. This switching process features the following attributes. It requires very little to change states (i.e., on and off). Furthermore, no power is required to maintain the states; hence, the state of the switch is nonvolatile. Because of these attributes the integration of a rectenna to provide the necessary power and control is unique to this embodiment. A rectenna, or rectifying antenna, generates DC power from an incident RF signal. The low voltages and power required for the nanoionic switch control are easily generated from this system and provide the switch with a novel capability to be operated and powered from an external wireless device. In one realization, an RF signal of a specific frequency can be used to set the switch into an off state, while another frequency can be used to set the switch to an on state. The wireless, miniaturized, and nomoving- part features of this switch make it

  7. The study of thermal change by chemoport in radiofrequency hyperthermia

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hoon; Lee, Sun Young; Gim, Yang Soo; Kwak, Keun Tak; Yang, Myung Sik; Cha, Seok Yong [Dept. of Radiation Oncology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2015-12-15

    This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. 20 cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is 24.5 - 25.5℃, humidity is 30% - 32%. In five-minute intervals to measure the output power of 100 W, 60 min. In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively 39.51℃, 39.11℃, 38.81℃, 40.64℃, simulated experimental data were 42.20 ℃, 41.50℃, 40.70℃, 42.50℃. And in the central axis electrode side 1.5 cm depth 2.8 cm, measured data were 39.37℃, 39.32℃, 39.20℃, 39.46℃, the simulated experimental data were 42.00℃, 41.80℃, 41.20℃, 42.30℃. The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the

  8. The study of thermal change by chemoport in radiofrequency hyperthermia

    International Nuclear Information System (INIS)

    Lee, Seung Hoon; Lee, Sun Young; Gim, Yang Soo; Kwak, Keun Tak; Yang, Myung Sik; Cha, Seok Yong

    2015-01-01

    This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. 20 cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is 24.5 - 25.5℃, humidity is 30% - 32%. In five-minute intervals to measure the output power of 100 W, 60 min. In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively 39.51℃, 39.11℃, 38.81℃, 40.64℃, simulated experimental data were 42.20 ℃, 41.50℃, 40.70℃, 42.50℃. And in the central axis electrode side 1.5 cm depth 2.8 cm, measured data were 39.37℃, 39.32℃, 39.20℃, 39.46℃, the simulated experimental data were 42.00℃, 41.80℃, 41.20℃, 42.30℃. The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the

  9. Adolescentes e grávidas: onde buscam apoio? Adolescentes embarazadas: donde buscan apoyo? Pregnant adolescents: where do they look for support?

    Directory of Open Access Journals (Sweden)

    Roselí Aparecida Godinho

    2000-04-01

    Full Text Available Adolescência é época de crise, mudança, readaptação ao novo corpo e de novas atitudes frente a vida. Se somarmos a isso o significado da gravidez, dos pontos de vista pessoal, social e familiar, compreenderemos como a gestação pode ser um evento difícil para a adolescente. O presente estudo teve como objetivo identificar onde as adolescentes grávidas buscam apoio. Evidenciou-se que as entrevistadas puderam contar com o apoio da família, principalmente dos pais e, com menos freqüência com o do pai do bebê, bem como a aceitação da gravidez, sua relação com o abandono escolar, a visão idealizada dessas garotas acerca da gestação e expectativas futuras, a preocupação com aspectos biológicos e a despreocupação com problemas concretos.La Adolescencia es una época de crisis, cambio, adaptación al nuevo cuerpo y de nuevos comportamientos frente a la vida. Si sumamos a esto el significado del embarazo, con sus aspectos personales, sociales y familiares, comprenderemos como el embarazo puede ser un evento difícil para la adolescente. Este trabajo tuvo como objetivo identificar donde las adolescentes embarazadas buscan apoyo. Evidenció que las entrevistadas tuvieron el apoyo de la familia, principalmente de los padres y con menor frecuencia el apoyo del padre de su bebé, así como la aceptación del embarazo, su relación con el abandono escolar, la visón idealizada de esas jóvenes acerca del embarazo y futuras expectativas, la preocupación con aspectos biológicos y la despreocupación con problemas concretos.Adolescence is the age of crises, changes, adaptation to the new body and new attitudes towards life. If we add to this the meaning of pregnancy from personal, social and family points of view, we will understand how difficult it can be for the adolescents. The purpose of this study was to identify where the pregnant teenagers look for support. Results showed that they had family support, mainly from parents, and

  10. Heat Sink Effect on Tumor Ablation Characteristics as Observed in Monopolar Radiofrequency, Bipolar Radiofrequency, and Microwave, Using Ex Vivo Calf Liver Model

    Science.gov (United States)

    Pillai, Krishna; Akhter, Javid; Chua, Terence C.; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L.

    2015-01-01

    Abstract Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices. With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored. With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres. Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected. Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5. MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink. PMID:25738477

  11. Polarization image segmentation of radiofrequency ablated porcine myocardial tissue.

    Directory of Open Access Journals (Sweden)

    Iftikhar Ahmad

    Full Text Available Optical polarimetry has previously imaged the spatial extent of a typical radiofrequency ablated (RFA lesion in myocardial tissue, exhibiting significantly lower total depolarization at the necrotic core compared to healthy tissue, and intermediate values at the RFA rim region. Here, total depolarization in ablated myocardium was used to segment the total depolarization image into three (core, rim and healthy zones. A local fuzzy thresholding algorithm was used for this multi-region segmentation, and then compared with a ground truth segmentation obtained from manual demarcation of RFA core and rim regions on the histopathology image. Quantitative comparison of the algorithm segmentation results was performed with evaluation metrics such as dice similarity coefficient (DSC = 0.78 ± 0.02 and 0.80 ± 0.02, sensitivity (Sn = 0.83 ± 0.10 and 0.91 ± 0.08, specificity (Sp = 0.76 ± 0.17 and 0.72 ± 0.17 and accuracy (Acc = 0.81 ± 0.09 and 0.71 ± 0.10 for RFA core and rim regions, respectively. This automatic segmentation of parametric depolarization images suggests a novel application of optical polarimetry, namely its use in objective RFA image quantification.

  12. Wavelet Domain Radiofrequency Pulse Design Applied to Magnetic Resonance Imaging.

    Directory of Open Access Journals (Sweden)

    Andrew M Huettner

    Full Text Available A new method for designing radiofrequency (RF pulses with numerical optimization in the wavelet domain is presented. Numerical optimization may yield solutions that might otherwise have not been discovered with analytic techniques alone. Further, processing in the wavelet domain reduces the number of unknowns through compression properties inherent in wavelet transforms, providing a more tractable optimization problem. This algorithm is demonstrated with simultaneous multi-slice (SMS spin echo refocusing pulses because reduced peak RF power is necessary for SMS diffusion imaging with high acceleration factors. An iterative, nonlinear, constrained numerical minimization algorithm was developed to generate an optimized RF pulse waveform. Wavelet domain coefficients were modulated while iteratively running a Bloch equation simulator to generate the intermediate slice profile of the net magnetization. The algorithm minimizes the L2-norm of the slice profile with additional terms to penalize rejection band ripple and maximize the net transverse magnetization across each slice. Simulations and human brain imaging were used to demonstrate a new RF pulse design that yields an optimized slice profile and reduced peak energy deposition when applied to a multiband single-shot echo planar diffusion acquisition. This method may be used to optimize factors such as magnitude and phase spectral profiles and peak RF pulse power for multiband simultaneous multi-slice (SMS acquisitions. Wavelet-based RF pulse optimization provides a useful design method to achieve a pulse waveform with beneficial amplitude reduction while preserving appropriate magnetization response for magnetic resonance imaging.

  13. Investigation of radiofrequency plasma sources for space travel

    International Nuclear Information System (INIS)

    Charles, C; Boswell, R W; Takahashi, K

    2012-01-01

    Optimization of radiofrequency (RF) plasma sources for the development of space thrusters differs from other applications such as plasma processing of materials since power efficiency, propellant usage, particle acceleration or heating become driving parameters. The development of two RF (13.56 MHz) plasma sources, the high-pressure (∼1 Torr) capacitively coupled ‘pocket rocket’ plasma micro-thruster and the low-pressure (∼1 mTorr) inductively coupled helicon double layer thruster (HDLT), is discussed within the context of mature and emerging electric propulsion devices. The density gradient in low-pressure expanding RF plasmas creates an electric field that accelerates positive ions out of the plasma. Generally, the total potential drop is similar to that of a wall sheath allowing the plasma electrons to neutralize the ion beam. A high-pressure expansion with no applied magnetic field can result in large dissociation rates and/or a collimated beam of ions of small area and a flowing heated neutral beam (‘pocket rocket’). A low-pressure expansion dominated by a magnetic field can result in the formation of electric double layers which produce a very directed neutralized beam of ions of large area (HDLT). (paper)

  14. Investigation of radiofrequency plasma sources for space travel

    Science.gov (United States)

    Charles, C.; Boswell, R. W.; Takahashi, K.

    2012-12-01

    Optimization of radiofrequency (RF) plasma sources for the development of space thrusters differs from other applications such as plasma processing of materials since power efficiency, propellant usage, particle acceleration or heating become driving parameters. The development of two RF (13.56 MHz) plasma sources, the high-pressure (˜1 Torr) capacitively coupled ‘pocket rocket’ plasma micro-thruster and the low-pressure (˜1 mTorr) inductively coupled helicon double layer thruster (HDLT), is discussed within the context of mature and emerging electric propulsion devices. The density gradient in low-pressure expanding RF plasmas creates an electric field that accelerates positive ions out of the plasma. Generally, the total potential drop is similar to that of a wall sheath allowing the plasma electrons to neutralize the ion beam. A high-pressure expansion with no applied magnetic field can result in large dissociation rates and/or a collimated beam of ions of small area and a flowing heated neutral beam (‘pocket rocket’). A low-pressure expansion dominated by a magnetic field can result in the formation of electric double layers which produce a very directed neutralized beam of ions of large area (HDLT).

  15. Radiofrequency exposure amongst employees of mobile network operators and broadcasters

    International Nuclear Information System (INIS)

    Litchfield, Ian; Sorahan, Tom; Tongeren, Martie van

    2017-01-01

    Little is known about personal exposure to radiofrequency (RF) fields amongst employees in the telecommunications industry responsible for installing and maintaining transmitters. IARC classified RF exposure as a possible carcinogen, although evidence from occupational studies was judged to be inadequate. Hence, there is a need for improved evidence of any potentially adverse health effects amongst the workforce occupationally exposed to RF radiation. In this study, results are presented from an exposure survey using data from personal monitors used by employees in the broadcasting and telecommunication industries of the UK. These data were supplemented by spot measurements using broadband survey metres and information on daily work activities provided by employee questionnaires. The sets of real-time personal data were categorised by four types of site determined by the highest powered antenna present (high, medium or low power and ground-level sites). For measurements gathered at each type of site, the root mean square and a series of box plots were produced. Results from the daily activities diaries suggested that riggers working for radio and television broadcasters were exposed to much longer periods as compared to colleagues working for mobile operators. Combining the results from the measurements and daily activity diaries clearly demonstrate that exposures were highest for riggers working for broadcasting sites. This study demonstrates that it is feasible to carry out exposure surveys within these populations that will provide reliable estimates of exposure that can be used for epidemiological studies of occupational groups exposed to RF fields. (authors)

  16. A survey of the urban radiofrequency (RF) environment

    International Nuclear Information System (INIS)

    Tell, Richard A.; Kavet, Robert

    2014-01-01

    In 1980, Tell and Mantiply published a study of radiofrequency (RF) fields measured across 15 major metropolitan areas in the USA. They required a van fully equipped with instrumentation and computing capability for their measurements. This study aimed to assess whether and how hand-held instrumentation available today would facilitate and enhance the efficiency of large-scale surveys of ambient RF fields. In addition, the data would provide a suggestion as to how the profile of ambient RF fields has changed with respect to frequency content and magnitude. Not unexpectedly, the relative power densities were orders of magnitude lower than the Federal Communications Commission's (FCC) maximum permissible exposure (MPE) for the general public, with a maximum time-averaged value across the VHF-FM-UHF-cellular bands of 0.12 % of the MPE (AM's contribution was negligible). In both the 1980 and the present study, the power density in the FM band was a major contributor to overall power density, but over time, power densities in the VHF and UHF band decreased and increased, respectively. From the perspective of absolute power density, the wideband values in the 1980 study, this study and any number of assessments conducted in European nations are not generally different from one another. (authors)

  17. Surgical and Pathological Changes after Radiofrequency Ablation of Thyroid Nodules

    Directory of Open Access Journals (Sweden)

    Chiara Dobrinja

    2015-01-01

    Full Text Available Background. Radiofrequency ablation (RFA has been recently advocated as an effective technique for the treatment of symptomatic benign thyroid nodules. It is not known to what extent it may affect any subsequent thyroid surgery and/or histological diagnosis. Materials and Methods. RFA was performed on 64 symptomatic Thy2 nodules (benign nodules and 6 symptomatic Thy3 nodules (follicular lesions/follicular neoplasms. Two Thy3 nodules regrew after the procedure, and these patients accepted to undergo a total thyroidectomy. Here we present how RFA has affected the operation and the final pathological features of the surgically removed nodules. Results and Conclusions. RFA is effective for the treatment of Thy2 nodules, but it should not be recommended as first-line therapy for the treatment of Thy3 nodules (irrespective of their mutational status, as it delays surgery in case of malignancy. Moreover, it is unknown whether RFA might promote residual tumor progression or neoplastic progression of Thy3 lesions. Nevertheless, here we show for the first time that one session of RFA does not affect subsequent thyroid surgery and/or histological diagnosis.

  18. ALINE: A device dedicated to understanding radio-frequency sheaths

    Directory of Open Access Journals (Sweden)

    S. Devaux

    2017-08-01

    Full Text Available In fusion devices, radiofrequency (RF antennas are used for heating the plasma. Those antennas and the plasma interact with each other through the so-called RF sheaths, layers of plasma where the quasi-neutrality breaks down and large electric fields arise. Among the effects of RF sheaths, there is the enhancement of the particles and energy fluxes toward the surface of the antenna, which in turn generate hot spots and release impurities, which are both deleterious for plasma operations. RF sheaths comprehension stumbles on the difficulty to achieve in situ measurements of the sheath properties, as scrape-off layer plasmas are a harsh environment. The very goal of the ALINE device is to tackle this issue and to fulfil the blank between numerical simulations and full-scale experiment by providing measurements within the RF sheaths in a controlled environment. In this paper we report on the latest experimental results from ALINE, in which a cylindrical Langmuir probe mounted on a remotely controlled and programmable arm allows for plasma characterizations in the three dimensions of space around the stainless steel antenna, including the sheath. We present a series of density and potential profiles and three dimension (3D maps in the plasma surrounding a stainless-steel RF antenna as well as in the sheath itself, for unmagnetized and magnetized plasmas.

  19. Value of radiofrequency ablation in the treatment of hepatocellular carcinoma

    Science.gov (United States)

    Feng, Kai; Ma, Kuan-Sheng

    2014-01-01

    Hepatocellular carcinoma (HCC) is a malignant disease that substantially affects public health worldwide. It is especially prevalent in east Asia and sub-Saharan Africa, where the main etiology is the endemic status of chronic hepatitis B. Effective treatments with curative intent for early HCC include liver transplantation, liver resection (LR), and radiofrequency ablation (RFA). RFA has become the most widely used local thermal ablation method in recent years because of its technical ease, safety, satisfactory local tumor control, and minimally invasive nature. This technique has also emerged as an important treatment strategy for HCC in recent years. RFA, liver transplantation, and hepatectomy can be complementary to one another in the treatment of HCC, and the outcome benefits have been demonstrated by numerous clinical studies. As a pretransplantation bridge therapy, RFA extends the average waiting time without increasing the risk of dropout or death. In contrast to LR, RFA causes almost no intra-abdominal adhesion, thus producing favorable conditions for subsequent liver transplantation. Many studies have demonstrated mutual interactions between RFA and hepatectomy, effectively expanding the operative indications for patients with HCC and enhancing the efficacy of these approaches. However, treated tumor tissue remains within the body after RFA, and residual tumors or satellite nodules can limit the effectiveness of this treatment. Therefore, future research should focus on this issue. PMID:24876721

  20. Radiofrequency fields in MAS solid state NMR probes

    Science.gov (United States)

    Tošner, Zdeněk; Purea, Armin; Struppe, Jochem O.; Wegner, Sebastian; Engelke, Frank; Glaser, Steffen J.; Reif, Bernd

    2017-11-01

    We present a detailed analysis of the radiofrequency (RF) field over full volume of a rotor that is generated in a solenoid coil. On top of the usually considered static distribution of amplitudes along the coil axis we describe dynamic radial RF inhomogeneities induced by sample rotation. During magic angle spinning (MAS), the mechanical rotation of the sample about the magic angle, a spin packet travels through areas of different RF fields and experiences periodical modulations of both the RF amplitude and the phase. These modulations become particularly severe at the end regions of the coil where the relative RF amplitude varies up to ±25% and the RF phase changes within ±30°. Using extensive numerical simulations we demonstrate effects of RF inhomogeneity on pulse calibration and for the ramped CP experiment performed at a wide range of MAS rates. In addition, we review various methods to map RF fields using a B0 gradient along the sample (rotor axis) for imaging purposes. Under such a gradient, a nutation experiment provides directly the RF amplitude distribution, a cross polarization experiment images the correlation of the RF fields on the two channels according to the Hartmann-Hahn matching condition, while a spin-lock experiment allows to calibrate the RF amplitude employing the rotary resonance recoupling condition. Knowledge of the RF field distribution in a coil provides key to understand its effects on performance of a pulse sequence at the spectrometer and enables to set robustness requirements in the experimental design.

  1. New Radiofrequency Exposure System with Real Telecommunication Signals

    Directory of Open Access Journals (Sweden)

    Jakub Misek

    2018-01-01

    Full Text Available In recent years, there has been an increase in the number of studies on biological effects of Electromagnetic (EM fields emitted from Base Transceiver Stations (BTSs. The biological effects of generated and real telecommunication signals produced by different types of exposure systems are discussed. However, the proper exposure methods for such experiments are very limited. We successfully developed a simple and cost-effective exposure unit with real GSM/DCS/UMTS signal from BTS containing proper modulations or intermittence (continuous, interrupted. Signal processing and conditioning unit is based on a Radiofrequency (RF repeater. The downlink signal is filtered by integrated high selectivity passband filters and amplified to a required level. The main part of exposure unit is a Faraday cage with the specimen (exposure area measuring 150 x 250 mm with E-field percent deviation less than 18%. This exposure system can be helpful in experiments with living organisms in in vivo studies and in vitro studies with normal or pathological cells and other micro scale structures being exposed to RF EM fields from BTS.

  2. Evaluation of stray radiofrequency radiation emitted by electrosurgical devices

    International Nuclear Information System (INIS)

    De Marco, M; Maggi, S

    2006-01-01

    Electrosurgery refers to the passage of a high-frequency, high-voltage electrical current through the body to achieve the desired surgical effects. At the same time, these procedures are accompanied by a general increase of the electromagnetic field in an operating room that may expose both patients and personnel to relatively high levels of radiofrequency radiation. In the first part of this study, we have taken into account the radiation emitted by different monopolar electrosurgical devices, evaluating the electromagnetic field strength delivered by an electrosurgical handle and straying from units and other electrosurgical accessories. As a summary, in the worst case a surgeon's hands are exposed to a continuous and pulsed RF wave whose magnetic field strength is 0.75 A m -1 (E-field 400 V m -1 ). Occasionally stray radiation may exceed ICNIRP's occupational exposure guidelines, especially close to the patient return plate. In the second part of this paper, we have analysed areas of particular concern to prevent electromagnetic interference with some life-support devices (ventilators and electrocardiographic devices), which have failed to operate correctly. Most clinically relevant interference occurred when an electrosurgery device was used within 0.3 m of medical equipment. In the appendix, we suggest some practical recommendations intended to minimize the potential for electromagnetic hazards due to therapeutic application of RF energy

  3. Importância da radiofrequência na oftalmologia

    Directory of Open Access Journals (Sweden)

    José Ricardo Carvalho Lima Rehder

    2013-04-01

    Full Text Available Este trabalho revisa e faz uma análise crítica da radiofrequência em oftalmologia. O aquecimento da córnea tem sido realizado desde 1889 com diferentes finalidades terapêuticas e cirúrgicas. O princípio do aquecimento da córnea causa um enrugamento do colágeno que muda a curvatura da córnea. Após a aprovação da FDA em 2004, iniciou-se um estudo multicêntrico no Brasil coordenado pela Faculdade de Medicina do ABC que resultou na análise de 258 pacientes. Como conclusão o estudo mostrou que o procedimento tem um resultado temporário e que os melhores resultados foram obtidos em pacientes entre 45 e 55 anos de idade sem correção óptica para longe. Acreditamos que o problema ainda não foi resolvido e que novas pesquisas devem ser realizadas.

  4. Percutaneous stereotactic radiofrequency ablation of colorectal liver metastases

    International Nuclear Information System (INIS)

    Bale, Reto; Widmann, Gerlig; Schullian, Peter; Haidu, Marion; Pall, Georg; Klaus, Alexander; Weiss, Helmut; Biebl, Matthias; Margreiter, Raimund

    2012-01-01

    To evaluate the outcome of patients with colorectal liver metastasis (CRLM) treated with stereotactic radiofrequency ablation (SRFA). Following IRB approval, a retrospective evaluation of 98 SRFA treatment sessions of 189 CRLMs in 63 consecutive patients was performed. Local recurrence rate (LR), overall survival (OS) and disease-free survival (DFS) were analysed. LR was identified in 16% of the tumours (31/189), with no significant differences (P = 0.635) when comparing tumour sizes 5 cm (17.4%). The median OS from SRFA treatment was 33.2 months after a mean follow-up of 25 months (range 2-66); the corresponding 1-, 3- and 5- year survival rates were 87%, 44% and 27%. The median OS was significantly different when comparing unresectable and resectable patients (27 vs. 58 months, P = 0.002) with OS rates of 92%, 66% and 48% at 1, 3 and 5 years in resectable patients. Tumour size did not affect OS and DFS. Due to the favourable outcome, SRFA challenges resection as first-line local treatment of patients with CRLM. As long as randomised studies are pending, we recommend entering an individual decision-making process with every patient. (orig.)

  5. Radiofrequency ablation of hepatocellular carcinoma: pros and cons.

    Science.gov (United States)

    Rhim, Hyunchul; Lim, Hyo K

    2010-09-01

    Among locoregional treatments for hepatocellular carcinoma (HCC), radiofrequency ablation (RFA) has been accepted as the most popular alternative to curative transplantation or resection, and it shows an excellent local tumor control rate and acceptable morbidity. The benefits of RFA have been universally validated by the practice guidelines of international societies of hepatology. The main advantages of RFA include 1) it is minimally invasive with acceptable morbidity, 2) it enables excellent local tumor control, 3) it has promising long-term survival, and 4) it is a multimodal approach. Based on these pros, RFA will play an important role in managing the patient with early HCC (smaller than 3 cm with fewer than four tumors). The main limitations of current RFA technology in hepatic ablation include 1) limitation of ablation volume, 2) technically infeasible in some tumors due to conspicuity and dangerous location, and 3) the heat-sink effect. Many technical approaches have been introduced to overcome those limitations, including a novel guiding modality, use of artificial fluid or air, and combined treatment strategies. RFA will continue to play a role as a representative ablative modality in the management of HCC, even in the era of targeted agents.

  6. Incidence and Cause of Hypertension During Adrenal Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Yamakado, Koichiro; Takaki, Haruyuki; Yamada, Tomomi; Yamanaka, Takashi; Uraki, Junji; Kashima, Masataka; Nakatsuka, Atsuhiro; Takeda, Kan

    2012-01-01

    Purpose: To evaluate the incidence and cause of hypertension prospectively during adrenal radiofrequency ablation (RFA). Methods: For this study, approved by our institutional review board, written informed consent was obtained from all patients. Patients who received RFA for adrenal tumors (adrenal ablation) and other abdominal tumors (nonadrenal ablation) were included in this prospective study. Blood pressure was monitored during RFA. Serum adrenal hormone levels including epinephrine, norepinephrine, dopamine, and cortisol levels were measured before and during RFA. The respective incidences of procedural hypertension (systolic blood pressure >200 mmHg) of the two patient groups were compared. Factors correlating with procedural systolic blood pressure were evaluated by regression analysis.ResultsNine patients underwent adrenal RFA and another 9 patients liver (n = 5) and renal (n = 4) RFA. Asymptomatic procedural hypertension that returned to the baseline by injecting calcium blocker was found in 7 (38.9%) of 18 patients. The incidence of procedural hypertension was significantly higher in the adrenal ablation group (66.7%, 6/9) than in the nonadrenal ablation group (11.1%, 1/9, P 2 = 0.68, P 2 = 0.72, P < 0.0001) levels during RFA. The other adrenal hormones did not show correlation with procedural systolic blood pressure. Conclusion: Hypertension occurs frequently during adrenal RFA because of the release of catecholamine.

  7. Percutaneous treatment of bone tumors by radiofrequency thermal ablation

    International Nuclear Information System (INIS)

    Ruiz Santiago, Fernando; Mar Castellano Garcia, Maria del; Guzman Alvarez, Luis; Martinez Montes, Jose Luis; Ruiz Garcia, Manuel; Tristan Fernandez, Juan MIguel

    2011-01-01

    We present our experience of the treatment of bone tumors with radiofrequency thermal ablation (RFTA). Over the past 4 years, we have treated 26 cases (22 benign and 4 malignant) using CT-guided RFTA. RFTA was the sole treatment in 19 cases and was combined with percutaneous cementation during the same session in the remaining seven cases. Our approach to the tumors was simplified, using a single point of entrance for both RFTA and percutaneous osteoplasty. In the benign cases, clinical success was defined as resolution of pain within 1 month of the procedure and no recurrence during the follow-up period. It was achieved in 19 out of the 21 patients in which curative treatment was attempted. The two non-resolved cases were a patient with osteoid osteoma who developed a symptomatic bone infarct after a symptom-free period of 2 months and another with femoral diaphysis osteoblastoma who suffered a pathological fracture after 8 months without symptoms. The procedure was considered clinically successful in the five cases (4 malign and 1 benign) in which palliative treatment was attempted, because there was a mean (±SD) reduction in visual analogue scale (VAS) pain score from 9.0 ± 0.4 before the procedure to <4 during the follow-up period.

  8. Radiofrequency-dressed-state potentials for neutral atoms

    DEFF Research Database (Denmark)

    Hofferberth, S.; Lesanovsky, Igor; Fischer, B.

    2006-01-01

    Potentials for atoms can be created by external fields acting on properties such as magnetic moment, charge, polarizability, or by oscillating fields that couple internal states. The most prominent realization of the latter is the optical dipole potential formed by coupling ground and electronica......Potentials for atoms can be created by external fields acting on properties such as magnetic moment, charge, polarizability, or by oscillating fields that couple internal states. The most prominent realization of the latter is the optical dipole potential formed by coupling ground...... and electronically excited states of an atom with light. Here, we present an extensive experimental analysis of potentials derived from radiofrequency (RF) coupling of electronic ground states. The coupling is magnetic and the vector character allows the design of versatile microscopic state-dependent potential...... landscapes. Compared with standard magnetic trapping, we find no additional heating or (collisional) loss up to densities of 1015 atoms cm-3. We demonstrate robust evaporative cooling in RF potentials, which allows easy production of Bose-Einstein condensates in complex potentials. Altogether, this makes RF...

  9. Synthesis of alkyl phenols by means of radiofrequency plasmas

    International Nuclear Information System (INIS)

    Ropero, M.; Armas, F.; Iacocca, D.; Patino, P.

    1992-01-01

    New and promising possibilities in chemical synthesis have been opened through the interactions of oxygen plasmas with liquid alkyl benzene compounds. The alkyl phenols are the main products of the reaction mixtures (> 80%) oxygen, excited by radio-frequency (R.F.) is allowed to reach the surface of the liquid organic compound. The R.F. power supply is a Branson/IPC-PM 118. The substrate we have chosen are: methyl, ethyl, propyl, n-butyl, t-butyl, dimethyl and trimethyl benzenes. Under the same O 2 pressure and a power of 60 W, m-xylene and mesethylene behaved similarly. For all these substrates, values for the temperature of the liquid surface seem to indicate that oxidation tends to an optimum when P O 2 /vapor pressure (substrate) is higher than 20. In our experiments oxygen pressure in the reactor was about 0.2 Torr. Oxidation is basically attributed to O 3 P and the addition to alkyl benzenes selectively takes place on the aromatic rings, at low reactor pressure. The oxygen atom impinges on the liquid surface and epoxy intermediates could be formed. These intermediates then progress to the corresponding phenols. (author)

  10. Delayed Development of Pneumothorax After Pulmonary Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Clasen, Stephan; Kettenbach, Joachim; Kosan, Bora; Aebert, Hermann; Schernthaner, Melanie; Kroeber, Stefan-Martin; Boemches, Andrea; Claussen, Claus D.; Pereira, Philippe L.

    2009-01-01

    Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days after ablation procedure. Underlying bronchopleural fistula along the coagulated former electrode track was diagnosed in two patients. In conclusion, delayed development of pneumothorax after pulmonary RF ablation can occur and is probably due to underlying bronchopleural fistula, potentially leading to tension pneumothorax. Patients and interventionalists should be prepared for delayed onset of this complication, and extensive track ablation following pulmonary RF ablation should be avoided.

  11. Radiofrequency Ablation of Lung Malignancies: Where Do We Stand?

    International Nuclear Information System (INIS)

    Lencioni, Riccardo; Crocetti, Laura; Cioni, Roberto; Mussi, Alfredo; Fontanini, Gabriella; Ambrogi, Marcello; Franchini, Chiara; Cioni, Dania; Fanucchi, Olivia; Gemignani, Raffaello; Baldassarri, Rubia; Angeletti, Carlo Alberto; Bartolozzi, Carlo

    2004-01-01

    Percutaneous radiofrequency (RF) ablation is a minimally invasive technique used to treat solid tumors. Because of its ability to produce large volumes of coagulation necrosis in a controlled fashion, this technique has gained acceptance as a viable therapeutic option for unresectable liver malignancies. Recently, investigation has been focused on the clinical application of RF ablation in the treatment of lung malignancies. In theory, lung tumors are well suited to RF ablation because the surrounding air in adjacent normal parenchyma provides an insulating effect, thus facilitating energy concentration within the tumor tissue. Experimental studies in rabbits have confirmed that lung RF ablation can be safely and effectively performed via a percutaneous, transthoracic approach, and have prompted the start of clinical investigation. Pilot clinical studies have shown that RF ablation enables successful treatment of relatively small lung malignancies with a high rate of complete response and acceptable morbidity, and have suggested that the technique could represent a viable alternate or complementary treatment method for patients with non-small cell lung cancer or lung metastases of favorable histotypes who are not candidates for surgical resection. This article gives an overview of lung RF ablation, discussing experimental animal findings, rationale for clinical application, technique and methodology, clinical results, and complications

  12. Actual role of radiofrequency ablation of liver metastases

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Philippe L. [Eberhard-Karls-University of Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany)

    2007-08-15

    The liver is, second only to lymph nodes, the most common site for metastatic disease irrespective of the primary tumour. More than 50% of all patients with malignant diseases will develop liver metastases with a significant morbidity and mortality. Although the surgical resection leads to an improved survival in patients with colorectal metastases, only approximately 20% of patients are eligible for surgery. Thermal ablation and especially radiofrequency ablation emerge as an important additional therapy modality for the treatment of liver metastases. RF ablation shows a benefit in life expectancy and may lead in a selected patient group to cure. Percutaneous RF ablation appears safer (versus cryotherapy), easier (versus laser), and more effective (versus ethanol instillation and transarterial chemoembolisation) compared with other minimally invasive procedures. RF ablation can be performed by a percutaneous, laparoscopical or laparotomic approach, and may be potentially combined with chemotherapy and surgery. At present ideal candidates have tumours with a maximum diameter less than 3.5 cm. An untreatable primary tumour or a systemic disease represents contraindications for performing local therapies. Permanent technical improvements of thermal ablation devices and a better integration of thermal ablation in the overall patient care may lead to prognosis improvement in patients with liver metastases. (orig.)

  13. Actual role of radiofrequency ablation of liver metastases

    International Nuclear Information System (INIS)

    Pereira, Philippe L.

    2007-01-01

    The liver is, second only to lymph nodes, the most common site for metastatic disease irrespective of the primary tumour. More than 50% of all patients with malignant diseases will develop liver metastases with a significant morbidity and mortality. Although the surgical resection leads to an improved survival in patients with colorectal metastases, only approximately 20% of patients are eligible for surgery. Thermal ablation and especially radiofrequency ablation emerge as an important additional therapy modality for the treatment of liver metastases. RF ablation shows a benefit in life expectancy and may lead in a selected patient group to cure. Percutaneous RF ablation appears safer (versus cryotherapy), easier (versus laser), and more effective (versus ethanol instillation and transarterial chemoembolisation) compared with other minimally invasive procedures. RF ablation can be performed by a percutaneous, laparoscopical or laparotomic approach, and may be potentially combined with chemotherapy and surgery. At present ideal candidates have tumours with a maximum diameter less than 3.5 cm. An untreatable primary tumour or a systemic disease represents contraindications for performing local therapies. Permanent technical improvements of thermal ablation devices and a better integration of thermal ablation in the overall patient care may lead to prognosis improvement in patients with liver metastases. (orig.)

  14. Exposure to radiofrequency radiation from diathermy units in medicine

    International Nuclear Information System (INIS)

    Hrnjak, M.; Zivkovic, D.; Milicevic, L.

    1998-01-01

    Intensities of microwave (MW) and radio wave (short wave) radiation to whom personnel occupied in use of radiofrequency (RF) diathermy in physical therapy could be exposed were measured in two hospitals, in two therapy wards. The Narda Microwave Corp. (USA) Broadband Radiation Meter - Model 8616, with appropriate probes, was used for measurements. The measurements were performed around the 3 types of diathermy units in various ways of application. Results of the measurements showed that the intensities of short waves radiation around the applicators, cables and units (at the distance of 30 cm) ranged from 187 mW/cm sup 2 , and on the majority of measuring points were considerably over the upper exposure limit of 1,22 mW/cm sup 2 (according to JUS N.NO.205:1190 limits of exposure to RF fields). Intensities of microwave radiation in the vicinity of units and patient range from <0,002 to 1,45 mW/cm sup 2. The intensities of MW radiation are over the exposure limit of 1 mW/cm sup 2 in two measuring points. Results of measurements show that personnel occupied in use of microwave and short wave diathermy in medicine could be regularly exposed to radiation, and that this radiation has considerably high intensity in the vicinity of the therapy unit and patient (author)

  15. Percutaneous treatment of bone tumors by radiofrequency thermal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Santiago, Fernando, E-mail: ferusan@ono.com [Department of Radiology, Hospital of Traumatology (Ciudad Sanitaria Virgen de las Nieves), Carretera de Jaen SN, 18013 Granada (Spain); Mar Castellano Garcia, Maria del; Guzman Alvarez, Luis [Department of Radiology, Hospital of Traumatology (Ciudad Sanitaria Virgen de las Nieves), Carretera de Jaen SN, 18013 Granada (Spain); Martinez Montes, Jose Luis [Department of Traumatology, Hospital of Traumatology (Ciudad Sanitaria Virgen de las Nieves), Carretera de Jaen SN, 18013 Granada (Spain); Ruiz Garcia, Manuel; Tristan Fernandez, Juan MIguel [Department of Radiology, Hospital of Traumatology (Ciudad Sanitaria Virgen de las Nieves), Carretera de Jaen SN, 18013 Granada (Spain)

    2011-01-15

    We present our experience of the treatment of bone tumors with radiofrequency thermal ablation (RFTA). Over the past 4 years, we have treated 26 cases (22 benign and 4 malignant) using CT-guided RFTA. RFTA was the sole treatment in 19 cases and was combined with percutaneous cementation during the same session in the remaining seven cases. Our approach to the tumors was simplified, using a single point of entrance for both RFTA and percutaneous osteoplasty. In the benign cases, clinical success was defined as resolution of pain within 1 month of the procedure and no recurrence during the follow-up period. It was achieved in 19 out of the 21 patients in which curative treatment was attempted. The two non-resolved cases were a patient with osteoid osteoma who developed a symptomatic bone infarct after a symptom-free period of 2 months and another with femoral diaphysis osteoblastoma who suffered a pathological fracture after 8 months without symptoms. The procedure was considered clinically successful in the five cases (4 malign and 1 benign) in which palliative treatment was attempted, because there was a mean ({+-}SD) reduction in visual analogue scale (VAS) pain score from 9.0 {+-} 0.4 before the procedure to <4 during the follow-up period.

  16. Radiofrequency Ablation Treatment for Renal Cell Carcinoma: Early Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seong Hoon; Yoon, Seong Kuk; Cho, Jin Han; Oh, Jong Young; Nam, Kyung Jin; Kwon, Hee Jin; Kim, Su Yeon; Kang, Myong Jin; Choi, Sun Seob; Sung, Gyung Tak [Dong-A University College of Medicine, Busan (Korea, Republic of)

    2008-08-15

    To evaluate the early clinical experience associated with radiofrequency (RF) ablation in patients with renal cell carcinoma (RCC). The RF ablation treatment was performed on 17 tumors from 16 patients (mean age, 60.5 years; range, 43 73 years) with RCC. The treatment indications were localized, solid renal mass, comorbidities, high operation risk, and refusal to perform surgery. All tumors were treated by a percutaneous CT (n = 10), followed by an US-guided (n = 2), laparoscopy-assisted US (n = 2), and an open (n = 2) RF ablation. Furthermore, patients underwent a follow- up CT at one day, one week, one month, three and six months, and then every six months from the onset of treatment. We evaluated the technical success, technical effectiveness, ablation zone, benign periablation enhancement, irregular peripheral enhancement, and complications. All 17 exophytic tumors (mean size, 2.2 cm; range, 1.1 5.0 cm) were completely ablated. Technical success and effectiveness was achieved in all cases and the mean follow-up period was 23.8 months (range, 17 33 months). A local recurrence was not detected in any of the cases; however, five patients developed complications as a result of treatment, including hematuria (n = 2), mild thermal injury of the psoas muscle (n = 1), mild hydronephrosis (n = 1), and fistula formation (n = 1). The RF ablation is an alternative treatment for exophytic RCCs and represents a promising treatment for some patients with small RCCs.

  17. Characterization of radiofrequency field emissions from smart meters.

    Science.gov (United States)

    Tell, Richard A; Kavet, Robert; Mezei, Gabor

    2013-01-01

    This study presents measurement data that describe radiofrequency emission levels and patterns from smart meters (rated nominally at 1 W) currently deployed in Pacific Gas and Electric Company's service territory in northern California. The smart meters in our investigation could not be set to operate continuously and required a Field Service Unit to induce short periods of emitted fields. To obtain peak field data under both laboratory and ambient conditions, a spectrum analyzer scanned across the 83 transmitting channels between 902 and 928 MHz used by the smart meter on a random frequency-hopping basis. To obtain data describing temporal emission patterns, the analyzer operated in scope mode. Duty cycle was estimated using transmit data acquired by the system operator from over 88,000 m. Instantaneous peak fields at 0.3 m in front of the meters were no more than 15% of the US Federal Communications Commission (FCC) exposure limit for the general public, and 99.9% of the meters operated with a duty cycle of 1.12% or less during the sampling period. In a sample of measurements in six single-detached residences equipped with individual smart meters, no interior measurement of peak field exceeded 1% of the FCC's general public exposure limit.

  18. Cell oxidation-reduction imbalance after modulated radiofrequency radiation.

    Science.gov (United States)

    Marjanovic, Ana Marija; Pavicic, Ivan; Trosic, Ivancica

    2015-01-01

    Aim of this study was to evaluate an influence of modulated radiofrequency field (RF) of 1800 MHz, strength of 30 V/m on oxidation-reduction processes within the cell. The assigned RF field was generated within Gigahertz Transversal Electromagnetic Mode cell equipped by signal generator, modulator, and amplifier. Cell line V79, was irradiated for 10, 30, and 60 min, specific absorption rate was calculated to be 1.6 W/kg. Cell metabolic activity and viability was determined by MTT assay. In order to define total protein content, colorimetric method was used. Concentration of oxidised proteins was evaluated by enzyme-linked immunosorbent assay. Reactive oxygen species (ROS) marked with fluorescent probe 2',7'-dichlorofluorescin diacetate were measured by means of plate reader device. In comparison with control cell samples, metabolic activity and total protein content in exposed cells did not differ significantly. Concentrations of carbonyl derivates, a product of protein oxidation, insignificantly but continuously increase with duration of exposure. In exposed samples, ROS level significantly (p < 0.05) increased after 10 min of exposure. Decrease in ROS level was observed after 30-min treatment indicating antioxidant defence mechanism activation. In conclusion, under the given laboratory conditions, modulated RF radiation might cause impairment in cell oxidation-reduction equilibrium within the growing cells.

  19. RADIOFREQUENCY AND MICROWAVE RADIATION HEALTH EFFECTS AND OCCUPATIONAL EXPOSURE

    Directory of Open Access Journals (Sweden)

    Ivana Damnjanović

    2011-12-01

    Full Text Available In the recent years, there have been considerable discussion and concern about the possible hazards of RF/MW radiation. More recently, the growth and development in personal mobile communications have focused attention on the frequencies associated with this technology. A number of studies have examined the health effects of RF/MW electromagnetic fields (EMFs, originating from occupational exposure, hobbies, or residence near the radio or television transmitters. Particularly controversial are the biophysical mechanisms by which these RF fields may affect biological systems. General health effects reviews explore possible carcinogenic, reproductive and neurological effects. Health effects by exposure source have been observed in radar traffic devices, wireless communications with cellular phones, radio transmission, and magnetic resonance imaging (MRI. Several epidemiological surveys have suggested associations with non-specific complaints such as headache, tiredness, sleep disturbance, loss of memory, and dizziness. These findings, which echo reports of illness associated with other types of radiofrequency (RF radiation, relate not only to the use of mobile phones, but also to residence near the mobile phone base stations and other settings involving occupational exposure. The biological effects suggest that some precautions are necessary, and preventive approaches are highly recommended. Further researches are required to give more information about the effects of microwave radiation on our health, especially in occupational setting and professionally exposed workers.

  20. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain

    Directory of Open Access Journals (Sweden)

    Binay Kumar Biswas

    2016-01-01

    Full Text Available Sacroiliac (SI joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] - 9/10 with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18th-month follow-up, he is pain free except for mild pain (NRS 2/10 on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment.

  1. Percutaneous radiofrequency ablation of osteoid osteomas. Technique and results

    International Nuclear Information System (INIS)

    Bruners, P.; Penzkofer, T.; Guenther, R. W.; Mahnken, A.

    2009-01-01

    Purpose: Osteoid osteoma is a benign primary bone tumor that typically occurs in children and young adults. Besides local pain, which is often worse at night, prompt relief due to medication with acetylsalicylic acid (ASS) is characteristic for this bone lesion. Because long-term medication with ASS does not represent an alternative treatment strategy due to its potentially severe side effects, different minimally invasive image-guided techniques for the therapy of osteoid osteoma have been developed. In this context radiofrequency (RF) ablation in particular has become part of the clinical routine. The technique and results of image-guided RF ablation are compared to alternative treatment strategies. Materials and Methods: Using this technique, an often needle-shaped RF applicator is percutaneously placed into the tumor under image guidance. Then a high-frequency alternating current is applied by the tip of the applicator which leads to ionic motion within the tissue resulting in local heat development and thus in thermal destruction of the surrounding tissue including the tumor. Results: The published primary and secondary success rates of this technique are 87 and 83%, respectively. Surgical resection and open curettage show comparable success rates but are associated with higher complication rates. In addition image-guided RF ablation of osteoid osteomas is associated with low costs. (orig.)

  2. Radiofrequency Ablation for Early-Stage Nonsmall Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Takao Hiraki

    2014-01-01

    Full Text Available This review examines studies of radiofrequency ablation (RFA of nonsmall cell lung cancer (NSCLC and discusses the role of RFA in treatment of early-stage NSCLC. RFA is usually performed under local anesthesia with computed tomography guidance. RFA-associated mortality, while being rare, can result from pulmonary events. RFA causes pneumothorax in up to 63% of cases, although pneumothorax requiring chest drainage occurs in less than 15% of procedures. Other severe complications are rare. After RFA of stage I NSCLC, 31–42% of patients show local progression. The 1-, 2-, 3-, and 5-year overall survival rates after RFA of stage I NSCLC were 78% to 100%, 53% to 86%, 36% to 88%, and 25% to 61%, respectively. The median survival time ranged from 29 to 67 months. The 1-, 2-, and 3-year cancer-specific survival rates after RFA of stage I NSCLC were 89% to 100%, 92% to 93%, and 59% to 88%, respectively. RFA has a higher local failure rate than sublobar resection and stereotactic body radiation therapy (SBRT. Therefore, RFA may currently be reserved for early-stage NSCLC patients who are unfit for sublobar resection or SBRT. Various technologies are being developed to improve clinical outcomes of RFA for early-stage NSCLC.

  3. Radiofrequency exposure in the Neonatal Medium Care Unit.

    Science.gov (United States)

    Calvente, I; Vázquez-Pérez, A; Fernández, M F; Núñez, M I; Múñoz-Hoyos, A

    2017-01-01

    The aims of this study were to characterize electromagnetic fields of radiofrequency (RF-EMF) levels generated in a Neonatal Medium Care Unit and to analyze RF-EMF levels inside unit's incubators. Spot and long-term measurements were made with a dosimeter. The spot measurement mean was 1.51±0.48V/m. Higher values were found in the proximity to the window and to the incubator evaluated. Mean field strength for the entire period of 17h was 0.81 (±0.07)V/m and the maximum value was 1.58V/m for long-term RF-EMF measurements in the incubator. Values found during the night period were higher than those found during the day period. It is important to consider RF-EMF exposure levels in neonatal care units, due to some evidence of adverse health effects found in children and adults. Characterization of RF-EMF exposure may be important to further investigate the mechanisms and underlying effects of electromagnetic fields (EMF) on infant health. A prudent avoidance strategy should be adopted because newborns are at a vulnerable stage of development and the actual impact of EMF on premature infants is unknown. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Kinetics and tissue repair process following fractional bipolar radiofrequency treatment.

    Science.gov (United States)

    Kokolakis, G; von Eichel, L; Ulrich, M; Lademann, J; Zuberbier, T; Hofmann, M A

    2018-05-15

    Fractionated radiofrequency (RF) tissue tightening is an alternative method to fractionated laser treatment of skin wrinkling, laxity and acne scars, with reduced risk of scarring or persistent pigmentation. The aim of this study was to evaluate and quantify the wound healing process after RF treatment. 12 patients were treated with a 64-pin fractional bipolar RF device with 60 mJ/pin applied energy. Confocal laser scanning microscopy (CLSM) examination was performed on day 1, day 2, day 7 and day 14 after treatment. Clinical wound healing process was measured and expressed as a percentage. All patients developed erythema, mild edema and crusts at the treated areas. Two weeks after treatment clinical symptoms resolved. During ablation patients reported moderate pain. Directly after ablation microscopic ablation zones could be detected in CLSM. Measurement of MAZ at epidermis, dermo-epidermal junction and papilary dermis showed a constant diameter until two weeks after treatment. Re-epithelization of the MAZ could be detected already 1 week after treatment. However, 2 weeks after ablation the honeycomb pattern of the epidermis was not yet completely restored. Bipolar fractionated RF treatment demonstrates clinically a rapid wound healing response. The subepidermal remodelling process still ongoing after 14 days, showing new granulation tissue. Therefore, treatment intervals of at least 14 days should be recommended to allow completion of the remodelling process.

  5. Radiofrequency Ablation Treatment for Renal Cell Carcinoma: Early Clinical Experience

    International Nuclear Information System (INIS)

    Park, Seong Hoon; Yoon, Seong Kuk; Cho, Jin Han; Oh, Jong Young; Nam, Kyung Jin; Kwon, Hee Jin; Kim, Su Yeon; Kang, Myong Jin; Choi, Sun Seob; Sung, Gyung Tak

    2008-01-01

    To evaluate the early clinical experience associated with radiofrequency (RF) ablation in patients with renal cell carcinoma (RCC). The RF ablation treatment was performed on 17 tumors from 16 patients (mean age, 60.5 years; range, 43 73 years) with RCC. The treatment indications were localized, solid renal mass, comorbidities, high operation risk, and refusal to perform surgery. All tumors were treated by a percutaneous CT (n = 10), followed by an US-guided (n = 2), laparoscopy-assisted US (n = 2), and an open (n = 2) RF ablation. Furthermore, patients underwent a follow- up CT at one day, one week, one month, three and six months, and then every six months from the onset of treatment. We evaluated the technical success, technical effectiveness, ablation zone, benign periablation enhancement, irregular peripheral enhancement, and complications. All 17 exophytic tumors (mean size, 2.2 cm; range, 1.1 5.0 cm) were completely ablated. Technical success and effectiveness was achieved in all cases and the mean follow-up period was 23.8 months (range, 17 33 months). A local recurrence was not detected in any of the cases; however, five patients developed complications as a result of treatment, including hematuria (n = 2), mild thermal injury of the psoas muscle (n = 1), mild hydronephrosis (n = 1), and fistula formation (n = 1). The RF ablation is an alternative treatment for exophytic RCCs and represents a promising treatment for some patients with small RCCs

  6. Experimental animal study of a novel radiofrequency endovascular occlusion device.

    Science.gov (United States)

    Zacharoulis, Dimitris; Lazoura, Olga; Rountas, Christos; Katsimboulas, Michael; Mantzianas, George; Tzovaras, George; Habib, Nagy

    2011-07-01

    The purpose of this study was to present a radiofrequency (RF) endovascular occlusion device (ie, Habib VesCoag Catheter; EMcision Ltd, London, UK) and to evaluate safety and efficacy of the device for complete occlusion of normal porcine vessels. The study included 20 pigs. In each pig, a segmental branch of the right hepatic artery, a branch of the splenic artery, and a branch of one of the renal arteries were catheterized. A single or multiple applications of RF energy were performed until vessel occlusion was achieved. Fifteen days later, angiography was repeated to assess vessel patency. The vessels were then excised for pathological analysis. Vessels 2.5 to 6 mm in diameter were treated. Complete occlusion with a single attempt was achieved using a mean amount of energy of 110.67 J in vessels 2.5 to 3 mm, 111.67 J in vessels 3.5 to 4 mm, and 116.63 J in vessels 5 to 6 mm in diameter and was confirmed by angiography at the 15-day follow-up. Vascular occlusion can be effectively and safely achieved by endovascular application of RF energy to normal porcine arteries using the Habib VesCoag catheter. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Liver resection with bipolar radiofrequency device: Habib 4X.

    Science.gov (United States)

    Pai, Madhava; Jiao, Long R; Khorsandi, Shirin; Canelo, Ruben; Spalding, Duncan R C; Habib, Nagy A

    2008-01-01

    Intraoperative blood loss has been shown to be an important factor correlating with morbidity and mortality in liver surgery. In spite of the technological advances in hepatic parenchymal transection devices, bleeding remains the single most important complication of liver surgery. The role of radiofrequency (RF) in liver surgery has been expanded from tumour ablation to major hepatic resections in the last decade. Habib 4X, a new bipolar RF device designed specifically for liver resection is described here. Habib 4X is a bipolar, handheld, disposable RF device and consists of two pairs of opposing electrodes which is introduced perpendicularly into the liver, along the intended transection line. It produces controlled RF energy between the electrodes and the heat produced seals even major biliary and blood vessels and enables resection of the liver parenchyma with a scalpel without blood loss or biliary leak. Three hundred and eleven patients underwent 384 liver resections from January 2002 to October 2007 with this device. There were 109 major resections and none of the patients had vascular inflow occlusion (Pringle's manoeuvre). Mean intraoperative blood loss was 305 ml (range 0-4300) ml, with less than 5% (n=18) rate of transfusion. Habib 4X is an additional device for hepatobiliary surgeons to perform liver resections with minimal blood loss and low morbidity and mortality rates.

  8. Tinnitus and cell phones: the role of electromagnetic radiofrequency radiation.

    Science.gov (United States)

    Medeiros, Luisa Nascimento; Sanchez, Tanit Ganz

    2016-01-01

    Tinnitus is a multifactorial condition and its prevalence has increased on the past decades. The worldwide progressive increase of the use of cell phones has exposed the peripheral auditory pathways to a higher dose of electromagnetic radiofrequency radiation (EMRFR). Some tinnitus patients report that the abusive use of mobiles, especially when repeated in the same ear, might worsen ipsilateral tinnitus. The aim of this study was to evaluate the available evidence about the possible causal association between tinnitus and exposure to electromagnetic waves. A literature review was performed searching for the following keywords: tinnitus, electromagnetic field, mobile phones, radio frequency, and electromagnetic hypersensitivity. We selected 165 articles that were considered clinically relevant in at least one of the subjects. EMRFR can penetrate exposed tissues and safety exposure levels have been established. These waves provoke proved thermogenic effects and potential biological and genotoxic effects. Some individuals are more sensitive to electromagnetic exposure (electrosensitivity), and thus, present earlier symptoms. There may be a common pathophysiology between this electrosensitivity and tinnitus. There are already reasonable evidences to suggest caution for using mobile phones to prevent auditory damage and the onset or worsening of tinnitus. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Incidence and Cause of Hypertension During Adrenal Radiofrequency Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Yamakado, Koichiro, E-mail: yama@clin.medic.mie-u.ac.jp; Takaki, Haruyuki [Mie University School of Medicine, Department of Interventional Radiology (Japan); Yamada, Tomomi [Mie University School of Medicine, Department of Translational Medicine (Japan); Yamanaka, Takashi; Uraki, Junji; Kashima, Masataka; Nakatsuka, Atsuhiro; Takeda, Kan [Mie University School of Medicine, Department of Interventional Radiology (Japan)

    2012-12-15

    Purpose: To evaluate the incidence and cause of hypertension prospectively during adrenal radiofrequency ablation (RFA). Methods: For this study, approved by our institutional review board, written informed consent was obtained from all patients. Patients who received RFA for adrenal tumors (adrenal ablation) and other abdominal tumors (nonadrenal ablation) were included in this prospective study. Blood pressure was monitored during RFA. Serum adrenal hormone levels including epinephrine, norepinephrine, dopamine, and cortisol levels were measured before and during RFA. The respective incidences of procedural hypertension (systolic blood pressure >200 mmHg) of the two patient groups were compared. Factors correlating with procedural systolic blood pressure were evaluated by regression analysis.ResultsNine patients underwent adrenal RFA and another 9 patients liver (n = 5) and renal (n = 4) RFA. Asymptomatic procedural hypertension that returned to the baseline by injecting calcium blocker was found in 7 (38.9%) of 18 patients. The incidence of procedural hypertension was significantly higher in the adrenal ablation group (66.7%, 6/9) than in the nonadrenal ablation group (11.1%, 1/9, P < 0.0498). Procedural systolic blood pressure was significantly correlated with serum epinephrine (R{sup 2} = 0.68, P < 0.0001) and norepinephrine (R{sup 2} = 0.72, P < 0.0001) levels during RFA. The other adrenal hormones did not show correlation with procedural systolic blood pressure. Conclusion: Hypertension occurs frequently during adrenal RFA because of the release of catecholamine.

  10. Challenges in Radiofrequency Pasteurization of Shell Eggs: Coagulation Rings.

    Science.gov (United States)

    Lau, Soon Kiat; Thippareddi, Harshavardhan; Jones, David; Negahban, Mehrdad; Subbiah, Jeyamkondan

    2016-10-01

    A total of 50 different configurations of simple radiofrequency (RF) heating at 27.12 MHz of a shell egg were simulated using a finite element model with the purpose of pasteurizing the egg. Temperature-dependent thermal and dielectric properties of the yolk, albumen, and shell were measured, fitted, and introduced into the model. A regression equation that relates the top electrode voltage to the gap between the electrodes and vertical position of the egg was developed. Simulation and experimental results had good agreement in terms of temperature deviation (root mean squared error ranged from 0.35 °C to 0.48 °C) and both results demonstrated the development of a "coagulation ring" around the air cell. The focused heating near the air cell of the egg prevented pasteurization of the egg due to its impact on quality (coagulation). Analysis of the electric field patterns offered a perspective on how nonuniform RF heating could occur in heterogeneous food products. The results can be used to guide development of RF heating for heterogeneous food products and further development of RF pasteurization of eggs. © 2016 Institute of Food Technologists®.

  11. Fallopian tube occlusion by selective transcatheter radiofrequency electrocautery

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Joo Hyeong; Yoon, Yup; Ko, Young Tae; Nam, Duck Ho; Park, Yong Koo [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1998-04-01

    The purpose of this study is to access the usefulness of transcatheter radiofrequency (RF) electrocautery as a method of nonsurgical tubal occlusion. Using the coaxial technique under fluoroscopic guidance, transvaginal fluoroscopic fallopian tube catheterization was performed in thirteen rabbits. In each rabbit, unilateral tubal ablation was performed using RF electrocautery. A 0.018 inch metallic wire protruding from the microcatheter tip was used as the source of the RF energy; the length of the noninsulated part of this wire was 10 mm and the duration of RF energy; the length of the noninsulated part of this wire 10 mm and the duration of RF supply was 20 seconds. The contralateral normal fallopian tube and uterus were used as a control. All 13 rabbits were randomly sacrificed on two days (group I) or 30 days (group II) after the procedure, and tubal patency and histologic change were evaluated. Transcatheter RF electrocautery is though to be a useful method for tubal occlusion. It is simple, safe, and less expensive and might have a role in future female tubal sterilization. (author). 25 refs., 1 tab., 4 figs.

  12. Fallopian tube occlusion by selective transcatheter radiofrequency electrocautery

    International Nuclear Information System (INIS)

    Oh, Joo Hyeong; Yoon, Yup; Ko, Young Tae; Nam, Duck Ho; Park, Yong Koo

    1998-01-01

    The purpose of this study is to access the usefulness of transcatheter radiofrequency (RF) electrocautery as a method of nonsurgical tubal occlusion. Using the coaxial technique under fluoroscopic guidance, transvaginal fluoroscopic fallopian tube catheterization was performed in thirteen rabbits. In each rabbit, unilateral tubal ablation was performed using RF electrocautery. A 0.018 inch metallic wire protruding from the microcatheter tip was used as the source of the RF energy; the length of the noninsulated part of this wire was 10 mm and the duration of RF energy; the length of the noninsulated part of this wire 10 mm and the duration of RF supply was 20 seconds. The contralateral normal fallopian tube and uterus were used as a control. All 13 rabbits were randomly sacrificed on two days (group I) or 30 days (group II) after the procedure, and tubal patency and histologic change were evaluated. Transcatheter RF electrocautery is though to be a useful method for tubal occlusion. It is simple, safe, and less expensive and might have a role in future female tubal sterilization. (author). 25 refs., 1 tab., 4 figs

  13. Is topical anesthesia useful in noninvasive skin tightening using radiofrequency?

    Science.gov (United States)

    Kushikata, Nobuharu; Negishi, Kei; Tezuka, Yukiko; Takeuchi, Kaori; Wakamatsu, Shingo

    2005-05-01

    The radiofrequency (RF) system has been applied to Asian skin for noninvasive skin tightening. The only drawback is the pain during the treatment. The relationships between the effectiveness of a topical anesthetic at various RF levels and the respective treatment results were compared and assessed after 3 months. Eighty-four females, ranging in age from 30 to 60 years, were divided into three groups of 28 subjects each. In all groups, the entire bilateral cheeks were treated. Group A underwent RF treatment (ThermaCool TC, Thermage, Hayward, CA, USA) with topical anesthesia and group B without anesthesia, and in group C, half of the face was treated with anesthesia and the other half was not. The degree of pain was recorded. Digital photographs of the patients pre- and post-treatment were objectively assessed by double-blinded physicians. Subjective assessment was performed with questionnaires. The average treatment levels for groups A and B were 14.13 and 14.02, respectively. Although anesthesia was useful for pain reduction, it did not allow a significant energy upgrade. In group C, 8 (28.6%) patients showed a statistically insignificant difference in the treatment levels, but not in the results, between the anesthetized and the unanesthetized sides. The use of anesthesia did not affect the final efficacy of the treatment compared with no anesthesia.

  14. Nonsurgical tightening of skin laxity: a new radiofrequency approach.

    Science.gov (United States)

    Rusciani, Antonio; Curinga, Giuseppe; Menichini, Giulio; Alfano, Carmine; Rusciani, Luigi

    2007-04-01

    Improvement in skin laxity can be difficult to achieve without invasive surgical procedures. Monopolar radiofrequency (RF) treatment is used by physicians to heat skin and promote tissue tightening and contouring. RF technology produces an electric current that generates heat through resistance in the dermis and subcutaneous tissue. The thermal effect depends on the conductivity features of the treated tissue. When heated, collagen fibrils will denature and contract, which is believed to lead to the observed tissue tightening. Ninety-three consecutive patients with mild to moderate laxity were included in the study. The Surgitron Dual Frequency RF (Radiowave technology, Ellman International) was used to treat skin laxity. The application of RF energy took place in an ambulatory setting with no need for skin sterilization or anesthesia. Patients immediately noticed a microlifting retraction in the treated tissues according to the vectors mapped in the area. There were no significant complications and the majority of patients were satisfied with the procedure and able to return to their daily routine after leaving the office, thereby substantiating the popularity of noninvasive rejuvenating procedures.

  15. Monopolar radiofrequency treatment of the eyelids: a safety evaluation.

    Science.gov (United States)

    Biesman, Brian S; Pope, Karl

    2007-07-01

    Monopolar radiofrequency (RF) energy has been used to successfully accomplish noninvasive skin tightening of the face, abdomen, and extremities. Owing to concerns about injury to the eye itself, monopolar RF treatment of the eyelids has not been feasible. The objective was to evaluate the safety of a novel 0.25-cm(2)"shallow" treatment tip for noninvasive tightening of eyelid skin. This was a tripartite study that began with an animal model to evaluate soft tissue effects and temperature change at the ocular surface. Findings were then extrapolated to ex vivo evaluation of human eyelids and ultimately to an in vivo human eyelid safety study. The animal studies demonstrated that the 0.25-cm(2) treatment tip could be used safely on eyelids in conjunction with appropriate ocular protection. The ex vivo human eyelid studies confirmed that, at typical treatment settings, the shallow treatment tip did not produce frank eyelid injury. The in vivo human studies confirmed that, at the tested settings, the novel treatment tip did not injure the eyelids or eyes. If used properly, the 0.25-cm(2) treatment tip can be safely used on human eyelids.

  16. Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating-phantom results

    International Nuclear Information System (INIS)

    Daniels, M J; Varghese, T; Madsen, E L; Zagzebski, J A

    2007-01-01

    Minimally invasive therapies (such as radiofrequency ablation) are becoming more commonly used in the United States for the treatment of hepatocellular carcinomas and liver metastases. Unfortunately, these procedures suffer from high recurrence rates of hepatocellular carcinoma (∼34-55%) or metastases following ablation therapy. The ability to perform real-time temperature imaging while a patient is undergoing radiofrequency ablation could provide a significant reduction in these recurrence rates. In this paper, we demonstrate the feasibility of ultrasound-based temperature imaging on a tissue-mimicking phantom undergoing radiofrequency heating. Ultrasound echo signals undergo time shifts with increasing temperature, which are tracked using 2D correlation-based speckle tracking methods. Time shifts or displacements in the echo signal are accumulated, and the gradient of these time shifts are related to changes in the temperature of the tissue-mimicking phantom material using a calibration curve generated from experimental data. A tissue-mimicking phantom was developed that can undergo repeated radiofrequency heating procedures. Both sound speed and thermal expansion changes of the tissue-mimicking material were measured experimentally and utilized to generate the calibration curve relating temperature to the displacement gradient. Temperature maps were obtained, and specific regions-of-interest on the temperature maps were compared to invasive temperatures obtained using fiber-optic temperature probes at the same location. Temperature elevation during a radiofrequency ablation procedure on the phantom was successfully tracked to within ±0.5 0 C

  17. Pulsed radiofrequency on radial nerve under ultrasound guidance for treatment of intractable lateral epicondylitis.

    Science.gov (United States)

    Oh, Dae Seok; Kang, Tae Hyung; Kim, Hyae Jin

    2016-06-01

    Lateral epicondylitis is a painful and functionally limiting disorder. Although lateral elbow pain is generally self-limiting, in a minority of people symptoms persist for a long time. When various conservative treatments fail, surgical approach is recommended. Surgical denervation of several nerves that innervate the lateral humeral epicondyle could be considered in patients with refractory pain because it denervates the region of pain. Pulsed radiofrequency is a minimally invasive procedure that improves chronic pain when applied to various neural tissues without causing any significant destruction and painful complication. This procedure is safe, minimally invasive, and has less risk of complications relatively compared to the surgical approach. The radial nerve can be identified as a target for pulsed radiofrequency lesioning in lateral epicondylitis. This innovative method of pulsed radiofrequency applied to the radial nerve has not been reported before. We reported on two patients with intractable lateral epicondylitis suffering from elbow pain who did not respond to nonoperative treatments, but in whom the ultrasound-guided pulsed radiofrequency neuromodulation of the radial nerve induced symptom improvement. After a successful diagnostic nerve block, radiofrequency probe adjustment around the radial nerve was performed on the lateral aspect of the distal upper arm under ultrasound guidance and multiple pulsed treatments were applied. A significant reduction in pain was reported over the follow-up period of 12 weeks.

  18. Radiofrequency energy in the arthroscopic treatment of knee chondral lesions: a systematic review.

    Science.gov (United States)

    Rocco, Papalia; Lorenzo, Diaz Balzani; Guglielmo, Torre; Michele, Paciotti; Nicola, Maffulli; Vincenzo, Denaro

    2016-03-01

    Cartilage debridement is one of the recommended procedures for the management of chondral defects. Radiofrequency probes allow to debride the cartilage, but may induce subchondral bone necrosis. Medline, Cochrane and Google Scholar were searched to identify studies on arthroscopic debridement of the articular cartilage of the knee using radiofrequency chondroplasty. The methodological quality of the studies was assessed using the Coleman methodology score (CMS). Monopolar and bipolar radiofrequency devices provide significantly better clinical outcomes, especially for patients with high-grade chondral lesions, compared with mechanical shaver only. Despite the original concerns regarding subchondral bone necrosis, low complication rates are reported. Heterogeneity in terms of type of device does not allow sound comparison of the published results. There is lack of evidence on the long-term effects of radiofrequency chondroplasty. Study methodology should be improved: the average Coleman methodology score was 56.2 out of 100. More comparative, well-designed and larger cohort trials are needed to ascertain whether radiofrequency chondroplasty offers long-term benefits over other simpler and more economical alternatives. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Effects of radiation from a radiofrequency identification (RFID) microchip on human cancer cells.

    Science.gov (United States)

    Lai, Henry C; Chan, Ho Wing; Singh, Narendra P

    2016-01-01

    Radiofrequency identification (RFID) microchips are used to remotely identify objects, e.g. an animal in which a chip is implanted. A passive RFID microchip absorbs energy from an external source and emits a radiofrequency identification signal which is then decoded by a detector. In the present study, we investigated the effect of the radiofrequency energy emitted by a RFID microchip on human cancer cells. Molt-4 leukemia, BT474 breast cancer, and HepG2 hepatic cancer cells were exposed in vitro to RFID microchip-emitted radiofrequency field for 1 h. Cells were counted before and after exposure. Effects of pretreatment with the spin-trap compound N-tert-butyl-alpha-phenylnitrone or the iron-chelator deferoxamine were also investigated. Results We found that the energy effectively killed/retarded the growth of the three different types of cancer cells, and the effect was blocked by the spin-trap compound or the iron-chelator, whereas an inactive microchip and energy from the external source had no significant effect on the cells. Conclusions Data of the present study suggest that radiofrequency field from the microchip affects cancer cells via the Fenton Reaction. Implantation of RFID microchips in tumors may provide a new method for cancer treatment.

  20. Radiofrequency ablation of hepatic metastasis: Results of treatment in forty patients

    Directory of Open Access Journals (Sweden)

    Rath G

    2008-01-01

    Full Text Available Aim: To evaluate the local control of hepatic metastasis with radiofrequency ablation treatment. Materials and Methods: We did a retrospective analysis in 40 patients treated with radiofrequency ablation for hepatic metastasis. The tumors ablated included up to two metastatic liver lesions, with primaries in breast, gastrointestinal tract, cervix, etc. Radiofrequency ablation was performed under general anesthesia in all cases, using ultrasound guidance. Radionics Cool-Tip RF System was used to deliver the treatment. Results: The median age of patients treated was 49 years. There were 13 female and 27 male patients. The median tumor size ablated was 1.5 cm (0.75-4.0 cm. A total of 52 radiofrequency ablation cycles were delivered. Successful ablation was achieved in all patients with hepatic metastasis less than 3 cm in size. Pain was the most common complication seen (75%. One patients developed skin burns. At 2-year follow-up 7.5% of patients had locally recurrent disease. Conclusions: Radiofrequency ablation is a minimally invasive treatment modality. It can be useful in a select group of patients with solitary liver metastasis of less than 3 cm size.

  1. Atorvastatin can ameliorate left atrial stunning induced by radiofrequency ablation for atrial fibrillation.

    Science.gov (United States)

    Xie, Ruiqin; Yang, Yingtao; Cui, Wei; Yin, Hongning; Zheng, Hongmei; Zhang, Jidong; You, Ling

    2017-09-01

    The objective of this study was to study the functional changes of the left atrium after radiofrequency ablation treatment for atrial fibrillation and the therapeutic effect of atorvastatin. Fifty-eight patients undergoing radiofrequency ablation for atrial fibrillation were randomly divided into non-atorvastatin group and atorvastatin group. Patients in the atorvastatin group were treated with atorvastatin 20 mg p.o. per night in addition to the conventional treatment of atrial fibrillation; patients in the non-atorvastatin group received conventional treatment of atrial fibrillation only. Echocardiography was performed before radiofrequency ablation operation and 1 week, 2 weeks, 3 weeks, and 4 weeks after operation. Two-dimensional ultrasound speckle tracking imaging system was used to measure the structural indexes of the left atrium. Results indicated that there was no significant change for indexes representing the structural status of the left atrium within a month after radiofrequency ablation (P > 0.05); however, there were significant changes for indexes representing the functional status of the left atrium. There were also significant changes in indexes reflecting left atrial strain status: the S and SRs of atorvastatin group were higher than those of non-atorvastatin group (P atorvastatin could improve left atrial function and shorten the duration of atrial stunning after radiofrequency ablation of atrial fibrillation.

  2. Percutaneous radiofrequency treatment of osteoid osteoma using cool-tip electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain)]. E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain); Ortiz, Eduardo [Departamento de Cirugia ortopedica, Fundacion Hospital Alcorcon, Madrid (Spain)

    2005-12-15

    Objectives: To report our experience with percutaneous cool-tip radiofrequency ablation of osteoid osteomas and to evaluate clinical outcome. Methods and material: Forty-one patients with clinically and radiologically suspected osteoid osteoma were seen over a 48-month period (27 males and 14 females with a mean age of 18.7 years; range 5-43 years). Thirty-eight patients were treated by computed tomography (CT)-guided percutaneous radiofrequency ablation. The procedure was performed under regional or general anaesthesia. After location of the nidus, a 14G-bone biopsy needle is introduced into the nidus. Sampling is performed with a 17G-bone biopsy needle using a coaxial technique. The radiofrequency needle with a 10 mm active tip (cool-tip) is inserted through the biopsy needle and is connected to the radiofrequency generator for 6-8 min. Results: Primary success was obtained in 37 patients (97%) with a 100% secondary success rate. All patients are currently pain-free. No major complications occurred. Patients could resume unrestricted normal activity within 24 h. Conclusions: Percutaneous radiofrequency ablation of osteoid osteomas is an efficient and safe method that can be considered the procedure of choice for most cases.

  3. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    Science.gov (United States)

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  4. Single strip lesions radiofrequency denervation for treatment of sacroiliac joint pain: two years' results.

    Science.gov (United States)

    Bellini, Martina; Barbieri, Massimo

    2016-01-01

    Sacroiliac joint pain can be managed by intra-articular injections or radiofrequency of its innervation. Single strip lesions radiofrequency denervation is a new system. The objective of this study was to present one of the first utilizations of this innovative technique. 60 patients who met the diagnostic criteria for sacroiliac joint syndrome were enrolled in the study. In total, 102 single strip lesions radiofrequency denervations were performed. Pain intensity was measured with the Oswestry low back pain disability questionnaire and the Oswestry Disability Index whose scores were assessed at 1, 3, 6 and 12 months after the procedure. 91.8 % of the 102 radiofrequency treatments resulted in a reduction of more than 50% pain intensity relief at 1 month, 81.6% at 3 months and 59.16% at 6 months. In 35.7% of cases, the relief was continuative up to 1 year. No relief was observed in 12.24% of cases. The ODI scores improved significantly 1 month after the procedure, compared with the baseline scores. The ODI scores after 6 months improved very clearly compared with the baseline scores and with the 3-month scores. Single strip lesions radiofrequency denervation using the Simplicity III probe is a potential modality for intermediate term relief for patients with sacroiliac pain.

  5. Reconfigurable radio-frequency arbitrary waveforms synthesized in a silicon photonic chip.

    Science.gov (United States)

    Wang, Jian; Shen, Hao; Fan, Li; Wu, Rui; Niu, Ben; Varghese, Leo T; Xuan, Yi; Leaird, Daniel E; Wang, Xi; Gan, Fuwan; Weiner, Andrew M; Qi, Minghao

    2015-01-12

    Photonic methods of radio-frequency waveform generation and processing can provide performance advantages and flexibility over electronic methods due to the ultrawide bandwidth offered by the optical carriers. However, bulk optics implementations suffer from the lack of integration and slow reconfiguration speed. Here we propose an architecture of integrated photonic radio-frequency generation and processing and implement it on a silicon chip fabricated in a semiconductor manufacturing foundry. Our device can generate programmable radio-frequency bursts or continuous waveforms with only the light source, electrical drives/controls and detectors being off-chip. It modulates an individual pulse in a radio-frequency burst within 4 ns, achieving a reconfiguration speed three orders of magnitude faster than thermal tuning. The on-chip optical delay elements offer an integrated approach to accurately manipulating individual radio-frequency waveform features without constraints set by the speed and timing jitter of electronics, and should find applications ranging from high-speed wireless to defence electronics.

  6. Hepatocellular carcinomas 2–3 cm in diameter: Transarterial chemoembolization plus radiofrequency ablation vs. radiofrequency ablation alone

    International Nuclear Information System (INIS)

    Kim, Jong Woo; Kim, Jin Hyoung; Won, Hyung Jin; Shin, Yong Moon; Yoon, Hyun-Ki; Sung, Kyu-Bo; Kim, Pyo Nyun

    2012-01-01

    Objective: There is debate whether transarterial chemoembolization (TACE) plus radiofrequency ablation (RFA) is more effective than RFA alone in the treatment of patients with small hepatocellular carcinoma (HCC). We therefore retrospectively compared these treatments in patients with HCCs of diameter 2–3 cm. Materials and methods: Outcomes, including tumor progression, survival rates, and major complications, were compared in 83 patients (83 tumors) treated with combined TACE and RFA and in 231 patients (231 tumors) treated with RFA alone. Results: Median follow-up periods were similar in the TACE + RFA and RFA alone groups (37 vs. 38 months). During follow-up, local tumor progression was observed in 16% and 41% of tumors, respectively. The 1, 3, and 5 year local tumor progression-free survival rates were significantly higher in the TACE + RFA group (95%, 86%, and 83%, respectively) than in the RFA-alone group (78%, 61%, and 53%, respectively; P < 0.001). The 1, 3, and 5 year overall survival rates, however, were similar in the TACE + RFA (93%, 72%, and 63%, respectively) and RFA (93%, 73%, and 53%, respectively) groups (P = 0.545), as were the rates of major complications (1.2% vs. 0.4%). Conclusions: Combined TACE and RFA was safe and provided better local tumor control than RFA alone in the treatment of 2- to 3-cm sized HCCs, although survival rates were similar.

  7. Bilateral occipital lobe infarction with altitudinal field loss following radiofrequency cardiac catheter ablation

    Directory of Open Access Journals (Sweden)

    Chen Celia S

    2010-03-01

    Full Text Available Abstract Background Bilateral stroke following radiofrequency catheter ablation is an unusual complication and may result in bilateral altitudinal visual field defects. Bilateral altitudinal visual field defects usually result from prechiasmal pathology causing damage to both retinas or optic nerves and rarely from bilateral symmetric damage to the post chiasmal visual pathways. Case presentation A 48-year-old man complained of visual disturbance on wakening following radiofrequency catheter ablation. The patient had a CHADS score of 1 pre-operatively and no complications were noted intra-operatively. Examination revealed a bilateral superior altitudinal defect and MRI of the brain showed multifocal areas of infarction predominantly involving the occipital lobes which correlated to with the visual deficits. Conclusion While the risk of thromboembolism and perioperative stroke during radiofrequency catheter ablation is small, it is not insignificant.

  8. Non-exponential decoherence of radio-frequency resonance rotation of spin in storage rings

    Science.gov (United States)

    Saleev, A.; Nikolaev, N. N.; Rathmann, F.; Hinder, F.; Pretz, J.; Rosenthal, M.

    2017-08-01

    Precision experiments, such as the search for electric dipole moments of charged particles using radio-frequency spin rotators in storage rings, demand for maintaining the exact spin resonance condition for several thousand seconds. Synchrotron oscillations in the stored beam modulate the spin tune of off-central particles, moving it off the perfect resonance condition set for central particles on the reference orbit. Here, we report an analytic description of how synchrotron oscillations lead to non-exponential decoherence of the radio-frequency resonance driven up-down spin rotations. This non-exponential decoherence is shown to be accompanied by a nontrivial walk of the spin phase. We also comment on sensitivity of the decoherence rate to the harmonics of the radio-frequency spin rotator and a possibility to check predictions of decoherence-free magic energies.

  9. Ion collection from laser-induced plasma by applying radio-frequency voltage

    International Nuclear Information System (INIS)

    Shibata, Takemasa; Ogura, Koichi

    1995-01-01

    Ions were collected on the electrodes from a laser resonance photoionized plasma by applying 1.8MHz radio-frequency voltage to the electrode. It was demonstrated that the ions are collected in a shorter time at the same kinetic energy of the collected ions compared with ion collection by applying DC voltage to the electrode. A simple one-dimensional model was extended for prediction of ion collection times in the cases of applications of not only the DC voltage but also the radio-frequency voltage. The ion collection times estimated using the simple one-dimensional model agreed with experimental values in both cases of DC and radio-frequency voltages. (author)

  10. Influence of transcatheter hepatic artery embolization using iodized oil on radiofrequency ablation of hepatic neoplasms

    International Nuclear Information System (INIS)

    Du Xilin; Ma Qingjiu; Wang Yiqing; Wang Zhimin; Zhang Hongxin

    2004-01-01

    Objective: To observe the effect of iodized oil on radiofrequency thermal ablation (RFA) of hepatic neoplasms by using a cluster array of ten separate electrodes. Methods: The patients were divided into 2 groups, group A with transcatheter hepatic artery embolization, group B without transcatheter hepatic artery embolization. All patients were undergone radiofrequency ablation of hepatic neoplasms. Results: The time of RFA for group A was (9 ± 2.1) minutes, showing the diameter of necrosis of (5.3 ± 1.4) cm. The time of RFA for group B was (16 ± 4. 6) minutes demonstrating the diameter of necrosis of (3.5 ± 1.8) cm (P<0.01). Conclusions: These findings suggest that radiofrequency thermal ablation of hepatic neoplasms with transcatheter hepatic artery embolization using iodized oil might improve the safety and synergic effect

  11. Radiofrequency glow discharge time of flight mass spectrometry: pulsed vs. continuous mode

    International Nuclear Information System (INIS)

    Lobo, L.; Pereiro, R.; Sanz-Medel, A.; Bordel, N.; Tempez, A.; Chapon, P.; Hohl, M.; Michler, J.

    2009-01-01

    Full text: Glow discharge (GD) is a well established tool for the direct analysis of solids. The application field of the original direct current GD, restricted to conductive samples, has been extended by radiofrequency powered GDs that can be applied for conductive and non-conductive samples. Moreover, the introduction of pulsed GD has opened the possibility of applying higher instantaneous powers that can improve the atomization-ionization processes and therefore the sensitivity. Furthermore, pulsed-GD may enable temporal separation of discharge gas species from the sample ions. In this work the analytical performances of radiofrequency and pulsed radiofrequency glow discharges are evaluated by using a time of flight mass analyzer (TOFMS). (author)

  12. Adaptive Response in Animals Exposed to Non-Ionizing Radiofrequency Fields: Some Underlying Mechanisms

    Directory of Open Access Journals (Sweden)

    Yi Cao

    2014-04-01

    Full Text Available During the last few years, our research group has been investigating the phenomenon of adaptive response in animals exposed to non-ionizing radiofrequency fields. The results from several separate studies indicated a significant increase in survival, decreases in genetic damage as well as oxidative damage and, alterations in several cellular processes in mice pre-exposed to radiofrequency fields and subsequently subjected to sub-lethal or lethal doses of γ-radiation or injected with bleomycin, a radiomimetic chemical mutagen. These observations indicated the induction of adaptive response providing the animals the ability to resist subsequent damage. Similar studies conducted by independent researchers in mice and rats have supported our observation on increased survival. In this paper, we have presented a brief review of all of our own and other independent investigations on radiofrequency fields-induced adaptive response and some underlying mechanisms discussed.

  13. Studies of elements used in hertzian interferometry (millimetric waves). Measurement of the permittivity of a liquid dielectric; Etudes d'elements utilises en interferometrie hertzienne (ondes millimetriques). Mesure de la permittivite de dielectrique liquide

    Energy Technology Data Exchange (ETDEWEB)

    Dagai, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-12-01

    Study of some elements used in EHF interferometry (bond of millimeter waves). This study is about design of the following elements: horns, horns associated with lens, power separators: -) Study of assemblies allowing measurements of complex dielectric constants of liquids. These devices are used in free propagation about wave lengths {<=} 2 mm; -) Studied devices: Interferometer for 2 separated waves and Michelson's type interferometer; -) 4 liquids have been used: {epsilon}'{sub r} Octane from -50 to 70 C (-58 to 158 F), {epsilon}'{sub r} and {epsilon}'' [Monochlorobenzene at 22,8 C (73 F), Mixture of octane with 10,8 per cent citral at 22 C (72 F) and Benzene at 21 C (70 F)]. -) Precision obtained about measurements: {delta}{epsilon}'/{epsilon}' de 1 a 2%, {delta}{epsilon}''/{epsilon}'' de 4 a 6%.(author) [French] Etudes d'elements utilises en interferometrie hertzienne fonctionnant en ondes millimetriques. Cette etude porte sur la realisation des elements suivants: cornets, cornets associes aux lentilles, separateurs de puissance. Etudes des montages permettant les mesures de la constante dielectrique complexe des corps liquides. Ces montages fonctionnent en propagation libre, sur des longueurs d'onde inferieures ou egales a 2 millimetres. Les montages etudies sont: interferometre a deux ondes separees et interferometre du type Michelson. De plus 4 liquides ont ete etudies: {epsilon}'{sub r} octane de -50 a 70 C, {epsilon}'{sub r} et {epsilon}'' [monochlorobenzene a 22,8 C et melange octane avec 10,8 pour cent citral a 22 C, Benzene a 21 C]. Les precisions obtenues sur les mesures sont: {delta}{epsilon}'/{epsilon}' de 1 a 2 pour cent, {delta}{epsilon}''/{epsilon}'' de 4 a 6 pour cent.

  14. INTRAOPERATIVE RADIOFREQUENCY AND CRYOABLATION FOR ATRIAL FIBRILLATION IN PATIENTS WITH VALVULAR HEART DISEASE

    Directory of Open Access Journals (Sweden)

    N. Maghamipour N. Safaie

    2007-05-01

    Full Text Available Patients with valvular heart disease and suffering atrial fibrillation of more than 12 months duration have a low probability of remaining in sinus rhythm after valve surgery alone. We performed intra-operative radiofrequency ablation or cryoablation as an alternative to surgical maze ІІІ procedure to create linear lesion lines for conversion of this arrhythmia to sinus rhythm. A total of 30 patients with valvular heart disease and chronic persistent atrial fibrillation underwent different combinations of valve surgery and concomitant maze procedure with radiofrequency or cryo probes. These patients aged 48.10 ± 9.84 years in radiofrequency ablation group and 51.10 ± 13.93 years in cryoablation group. Both atrial ablation with radiofrequency probes, needed 26.15 ± 3.67 min extra ischemic time and ablation by mean of cryo-probes needed an extra ischemic time of 29.62 ± 4.27 min. There was one in hospital death postoperatively because of respiratory failure but no other complication. 6 months after the operation, among 30 patients with both atrial ablations, 25 patients were in sinus rhythm, no patient had junctional rhythm and 5 patients had persistent atrial fibrillation. At 12 months follow up, freedom from atrial fibrillation was 85% in radiofrequency group and 80% in cryo group. Doppler echocardiography in these patients demonstrated atrial contractility in 70% of the patients. Intraoperative radiofrequency or cryo-ablation of both atriums are effective and less invasive alternatives for the original maze procedure to eliminate the atrial fibrillation, and can be done in patients with valvular heart disease without increasing the risk of operation.

  15. Comparison of QuadrapolarTM radiofrequency lesions produced by standard versus modified technique: an experimental model

    Directory of Open Access Journals (Sweden)

    Safakish R

    2017-06-01

    Full Text Available Ramin Safakish Allevio Pain Management Clinic, Toronto, ON, Canada Abstract: Lower back pain (LBP is a global public health issue and is associated with substantial financial costs and loss of quality of life. Over the years, different literature has provided different statistics regarding the causes of the back pain. The following statistic is the closest estimation regarding our patient population. The sacroiliac (SI joint pain is responsible for LBP in 18%–30% of individuals with LBP. Quadrapolar™ radiofrequency ablation, which involves ablation of the nerves of the SI joint using heat, is a commonly used treatment for SI joint pain. However, the standard Quadrapolar radiofrequency procedure is not always effective at ablating all the sensory nerves that cause the pain in the SI joint. One of the major limitations of the standard Quadrapolar radiofrequency procedure is that it produces small lesions of ~4 mm in diameter. Smaller lesions increase the likelihood of failure to ablate all nociceptive input. In this study, we compare the standard Quadrapolar radiofrequency ablation technique to a modified Quadrapolar ablation technique that has produced improved patient outcomes in our clinic. The methodology of the two techniques are compared. In addition, we compare results from an experimental model comparing the lesion sizes produced by the two techniques. Taken together, the findings from this study suggest that the modified Quadrapolar technique provides longer lasting relief for the back pain that is caused by SI joint dysfunction. A randomized controlled clinical trial is the next step required to quantify the difference in symptom relief and quality of life produced by the two techniques. Keywords: lower back pain, radiofrequency ablation, sacroiliac joint, Quadrapolar radiofrequency ablation

  16. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    Science.gov (United States)

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  17. Radiofrequency exposure in the Neonatal Medium Care Unit

    International Nuclear Information System (INIS)

    Calvente, I.; Vázquez-Pérez, A.; Fernández, M.F.; Núñez, M.I.; Múñoz-Hoyos, A.

    2017-01-01

    The aims of this study were to characterize electromagnetic fields of radiofrequency (RF-EMF) levels generated in a Neonatal Medium Care Unit and to analyze RF-EMF levels inside unit’s incubators. Spot and long-term measurements were made with a dosimeter. The spot measurement mean was 1.51±0.48 V/m. Higher values were found in the proximity to the window and to the incubator evaluated. Mean field strength for the entire period of 17 h was 0.81 (±0.07) V/m and the maximum value was 1.58 V/m for long-term RF-EMF measurements in the incubator. Values found during the night period were higher than those found during the day period. It is important to consider RF-EMF exposure levels in neonatal care units, due to some evidence of adverse health effects found in children and adults. Characterization of RF-EMF exposure may be important to further investigate the mechanisms and underlying effects of electromagnetic fields (EMF) on infant health. A prudent avoidance strategy should be adopted because newborns are at a vulnerable stage of development and the actual impact of EMF on premature infants is unknown. - Highlights: • The increasing use of RF-EMF suggests an urgent need for more research in this field. • Health consequences of RF-EMF exposure on infants are not well known. • Description of RF-EMF exposure is vital in further study mechanisms on infant health. • Considering newborns vulnerability, it is wise to adopt a prudent avoidance strategy.

  18. Impact of radiofrequency ablation geometry on electrical conduction

    Science.gov (United States)

    Rivas, Rhiana N.; Lye, Theresa H.; Hendon, Christine P.

    2018-02-01

    The gold standard of current treatment for atrial fibrillation is radiofrequency ablation (RFA). Single RFA procedures have low long-term, single-procedure success rates, which can be attributed to factors including inability to measure and visualize lesion depth in real time and incomplete knowledge of how atrial fibrillation manifests and persists. One way to address this problem is to develop a heart model that accurately fits lesion dimensions and depth using OCT to extract structural information. Twenty-three lesions of varying transmurality in left and right swine atrial tissue have been imaged with a Thorlabs OCT system with 6.5-micron axial resolution and a custom Ultra High Resolution system with 2.5-micron axial resolution. The boundaries of the ablation lesions were identified by the appearance of the birefringence artifact to identify areas of un-ablated tissue, as well as by changes to depth penetration and structural features, including decreased contrast between the endocardium and myocardium and disappearance of collagen fibers within the ablation lesion. Using these features, the lateral positions of the lesion boundaries were identified. An algorithm that fit ellipses to the lesion contours modeled the ablation geometry in depth. Lesion dimensions and shape were confirmed by comparison with trichrome histological processing. Finite-element models were fitted with these parameters and electrophysiological simulations were run with the Continuity 6 package. Next steps include correlating lesion geometry to conduction velocity, and including further tissue complexity such as varying tissue composition and fiber orientation. Additional models of linear lesions with gaps and adjacent lesions created with non-perpendicular contact will be created. This work will provide insight into how lesion geometry, tissue composition, and fiber organization impact electrophysiological propagation.

  19. Adaptive ultrasound temperature imaging for monitoring radiofrequency ablation.

    Directory of Open Access Journals (Sweden)

    Yi-Da Liu

    Full Text Available Radiofrequency ablation (RFA has been widely used as an alternative treatment modality for liver tumors. Monitoring the temperature distribution in the tissue during RFA is required to assess the thermal dosage. Ultrasound temperature imaging based on the detection of echo time shifts has received the most attention in the past decade. The coefficient k, connecting the temperature change and the echo time shift, is a medium-dependent parameter used to describe the confounding effects of changes in the speed of sound and thermal expansion as temperature increases. The current algorithm of temperature estimate based on echo time shift detection typically uses a constant k, resulting in estimation errors when ablation temperatures are higher than 50°C. This study proposes an adaptive-k algorithm that enables the automatic adjustment of the coefficient k during ultrasound temperature monitoring of RFA. To verify the proposed algorithm, RFA experiments on in vitro porcine liver samples (total n = 15 were performed using ablation powers of 10, 15, and 20 W. During RFA, a clinical ultrasound system equipped with a 7.5-MHz linear transducer was used to collect backscattered signals for ultrasound temperature imaging using the constant- and adaptive-k algorithms. Concurrently, an infrared imaging system and thermocouples were used to measure surface temperature distribution of the sample and internal ablation temperatures for comparisons with ultrasound estimates. Experimental results demonstrated that the proposed adaptive-k method improved the performance in visualizing the temperature distribution. In particular, the estimation errors were also reduced even when the temperature of the tissue is higher than 50°C. The proposed adaptive-k ultrasound temperature imaging strategy has potential to serve as a thermal dosage evaluation tool for monitoring high-temperature RFA.

  20. Radiofrequency-electromagnetic field exposures in kindergarten children.

    Science.gov (United States)

    Bhatt, Chhavi Raj; Redmayne, Mary; Billah, Baki; Abramson, Michael J; Benke, Geza

    2017-09-01

    The aim of this study was to assess environmental and personal radiofrequency-electromagnetic field (RF-EMF) exposures in kindergarten children. Ten children and 20 kindergartens in Melbourne, Australia participated in personal and environmental exposure measurements, respectively. Order statistics of RF-EMF exposures were computed for 16 frequency bands between 88 MHz and 5.8 GHz. Of the 16 bands, the three highest sources of environmental RF-EMF exposures were: Global System for Mobile Communications (GSM) 900 MHz downlink (82 mV/m); Universal Mobile Telecommunications System (UMTS) 2100MHz downlink (51 mV/m); and GSM 900 MHz uplink (45 mV/m). Similarly, the three highest personal exposure sources were: GSM 900 MHz downlink (50 mV/m); UMTS 2100 MHz downlink, GSM 900 MHz uplink and GSM 1800 MHz downlink (20 mV/m); and Frequency Modulation radio, Wi-Fi 2.4 GHz and Digital Video Broadcasting-Terrestrial (10 mV/m). The median environmental exposures were: 179 mV/m (total all bands), 123 mV/m (total mobile phone base station downlinks), 46 mV/m (total mobile phone base station uplinks), and 16 mV/m (Wi-Fi 2.4 GHz). Similarly, the median personal exposures were: 81 mV/m (total all bands), 62 mV/m (total mobile phone base station downlinks), 21 mV/m (total mobile phone base station uplinks), and 9 mV/m (Wi-Fi 2.4 GHz). The measurements showed that environmental RF-EMF exposure levels exceeded the personal RF-EMF exposure levels at kindergartens.

  1. The effects of radiofrequency electromagnetic radiation on sperm function.

    Science.gov (United States)

    Houston, B J; Nixon, B; King, B V; De Iuliis, G N; Aitken, R J

    2016-12-01

    Mobile phone usage has become an integral part of our lives. However, the effects of the radiofrequency electromagnetic radiation (RF-EMR) emitted by these devices on biological systems and specifically the reproductive systems are currently under active debate. A fundamental hindrance to the current debate is that there is no clear mechanism of how such non-ionising radiation influences biological systems. Therefore, we explored the documented impacts of RF-EMR on the male reproductive system and considered any common observations that could provide insights on a potential mechanism. Among a total of 27 studies investigating the effects of RF-EMR on the male reproductive system, negative consequences of exposure were reported in 21. Within these 21 studies, 11 of the 15 that investigated sperm motility reported significant declines, 7 of 7 that measured the production of reactive oxygen species (ROS) documented elevated levels and 4 of 5 studies that probed for DNA damage highlighted increased damage due to RF-EMR exposure. Associated with this, RF-EMR treatment reduced the antioxidant levels in 6 of 6 studies that discussed this phenomenon, whereas consequences of RF-EMR were successfully ameliorated with the supplementation of antioxidants in all 3 studies that carried out these experiments. In light of this, we envisage a two-step mechanism whereby RF-EMR is able to induce mitochondrial dysfunction leading to elevated ROS production. A continued focus on research, which aims to shed light on the biological effects of RF-EMR will allow us to test and assess this proposed mechanism in a variety of cell types. © 2016 Society for Reproduction and Fertility.

  2. Palliative Treatment of Rectal Carcinoma Recurrence Using Radiofrequency Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Mylona, Sophia, E-mail: mylonasophia@yahoo.com; Karagiannis, Georgios, E-mail: gekaragiannis@yahoo.gr; Patsoura, Sofia, E-mail: sofia.patsoura@yahoo.gr [Hellenic Red Cross Hospital ' Korgialenio-Benakio' (Greece); Galani, Panagiota, E-mail: gioulagalani@yahoo.com [Amalia Fleming Hospital (Greece); Pomoni, Maria, E-mail: marypomoni@gmail.com [Evgenidion Hospital (Greece); Thanos, Loukas, E-mail: loutharad@yahoo.com [Sotiria Hospital (Greece)

    2012-08-15

    Purpose: To evaluate the safety and efficacy of CT-guided radiofrequency (RF) ablation for the palliative treatment of recurrent unresectable rectal tumors. Materials and Methods: Twenty-seven patients with locally recurrent rectal cancer were treated with computed tomography (CT)-guided RF ablation. Therapy was performed with the patient under conscious sedation with a seven- or a nine-array expandable RF electrode for 8-10 min at 80-110 Degree-Sign C and a power of 90-110 W. All patients went home under instructions the next day of the procedure. Brief Pain Inventory score was calculated before and after (1 day, 1 week, 1 month, 3 months, and 6 months) treatment. Results: Complete tumor necrosis rate was 77.8% (21 of a total 27 procedures) despite lesion location. BPI score was dramatically decreased after the procedure. The mean preprocedure BPI score was 6.59, which decreased to 3.15, 1.15, and 0.11 at postprocedure day 1, week 1, and month 1, respectively, after the procedure. This decrease was significant (p < 0.01 for the first day and p < 0.001 for the rest of the follow-up intervals (paired Student t test; n - 1 = 26) for all periods during follow-up. Six patients had partial tumor necrosis, and we were attempted to them with a second procedure. Although the necrosis area showed a radiographic increase, no complete necrosis was achieved (secondary success rate 65.6%). No immediate or delayed complications were observed. Conclusion: CT-guided RF ablation is a minimally invasive, safe, and highly effective technique for treatment of malignant rectal recurrence. The method is well tolerated by patients, and pain relief is quickly achieved.

  3. Lung Tumor Radiofrequency Ablation: Where Do We Stand?

    International Nuclear Information System (INIS)

    Baère, Thierry de

    2011-01-01

    Today, radiofrequency ablation (RFA) of primary and metastatic lung tumor is increasingly used. Because RFA is most often used with curative intent, preablation workup must be a preoperative workup. General anesthesia provides higher feasibility than conscious sedation. The electrode positioning must be performed under computed tomography for sake of accuracy. The delivery of RFA must be adapted to tumor location, with different impedances used when treating tumors with or without pleural contact. The estimated rate of incomplete local treatment at 18 months was 7% (95% confidence interval, 3–14) per tumor, with incomplete treatment depicted at 4 months (n = 1), 6 months (n = 2), 9 months (n = 2), and 12 months (n = 2). Overall survival and lung disease-free survival at 18 months were, respectively, 71 and 34%. Size is a key point for tumor selection because large size is predictive of incomplete local treatment and poor survival. The ratio of ablation volume relative to tumor volume is predictive of complete ablation. Follow-up computed tomography that relies on the size of the ablation zone demonstrates the presence of incomplete ablation. Positron emission tomography might be an interesting option. Chest tube placement for pneumothorax is reported in 8 to 12%. Alveolar hemorrhage and postprocedure hemoptysis occurred in approximately 10% of procedures and rarely required specific treatment. Death was mostly related to single-lung patients and hilar tumors. No modification of forced expiratory volume in the first second between pre- and post-RFA at 2 months was found. RFA in the lung provides a high local efficacy rate. The use of RFA as a palliative tool in combination with chemotherapy remains to be explored.

  4. Palliative Treatment of Rectal Carcinoma Recurrence Using Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Mylona, Sophia; Karagiannis, Georgios; Patsoura, Sofia; Galani, Panagiota; Pomoni, Maria; Thanos, Loukas

    2012-01-01

    Purpose: To evaluate the safety and efficacy of CT-guided radiofrequency (RF) ablation for the palliative treatment of recurrent unresectable rectal tumors. Materials and Methods: Twenty-seven patients with locally recurrent rectal cancer were treated with computed tomography (CT)-guided RF ablation. Therapy was performed with the patient under conscious sedation with a seven- or a nine-array expandable RF electrode for 8–10 min at 80–110°C and a power of 90–110 W. All patients went home under instructions the next day of the procedure. Brief Pain Inventory score was calculated before and after (1 day, 1 week, 1 month, 3 months, and 6 months) treatment. Results: Complete tumor necrosis rate was 77.8% (21 of a total 27 procedures) despite lesion location. BPI score was dramatically decreased after the procedure. The mean preprocedure BPI score was 6.59, which decreased to 3.15, 1.15, and 0.11 at postprocedure day 1, week 1, and month 1, respectively, after the procedure. This decrease was significant (p < 0.01 for the first day and p < 0.001 for the rest of the follow-up intervals (paired Student t test; n − 1 = 26) for all periods during follow-up. Six patients had partial tumor necrosis, and we were attempted to them with a second procedure. Although the necrosis area showed a radiographic increase, no complete necrosis was achieved (secondary success rate 65.6%). No immediate or delayed complications were observed. Conclusion: CT-guided RF ablation is a minimally invasive, safe, and highly effective technique for treatment of malignant rectal recurrence. The method is well tolerated by patients, and pain relief is quickly achieved.

  5. Radiofrequency ablation for hepatocellular carcinoma: assistant techniques for difficult cases.

    Science.gov (United States)

    Inoue, Tatsuo; Minami, Yasunori; Chung, Hobyung; Hayaishi, Sousuke; Ueda, Taisuke; Tatsumi, Chie; Takita, Masahiro; Kitai, Satoshi; Hatanaka, Kinuyo; Ishikawa, Emi; Yada, Norihisa; Hagiwara, Satoru; Ueshima, Kazuomi; Kudo, Masatoshi

    2010-07-01

    To confirm the safety and effectiveness of techniques to assist radiofrequency ablation (RFA) for difficult cases, we retrospectively evaluated successful treatment rates, early complications and local tumor progressions. Between June 1999 and April 2009, a total of 341 patients with 535 nodules were treated as difficult cases. Artificial pleural effusion assisted ablation was performed on 64 patients with 82 nodules. Artificial ascites-assisted ablation was performed on 11 patients with 13 nodules. Cooling by endoscopic nasobiliary drainage (ENBD) tube-assisted ablation was performed on 6 patients with 8 nodules. When the tumors were not well visualized with conventional B-mode ultrasonography (US), contrast-enhanced US-assisted ablation with Levovist or Sonazoid or virtual CT sonography-assisted ablation was performed. Contrast-enhanced US-assisted ablation was performed on 139 patients with 224 nodules and virtual CT sonography-assisted ablation was performed on 121 patients with 209 nodules. In total, complete ablation was achieved in 514 of 535 (96%) nodules in difficult cases. For RFA with artificial pleural effusion, artificial ascites and ENBD, complete response was confirmed in all cases. For contrast-enhanced US- and CT sonography-assisted ablation, complete response was 95%. Early complications were recognized in 24 cases (4.5%). All cases recovered with no invasive treatment. Local tumor recurrence was investigated in 377 nodules of 245 patients, and 69 (18%) nodules were positive. Tumor recurrences in each assisted technique were 14.7% in artificial pleural effusion cases, 7% in artificial ascites, 12.5% in ENBD tube cases, 31% in virtual CT sonography, and 8.5% in contrast-enhanced US. Although local tumor progression needs to be carefully monitored, assisted techniques of RFA for difficult cases are well tolerated and expand the indications of RFA. Copyright (c) 2010 S. Karger AG, Basel.

  6. Effects of Radiofrequency Induced local Hyperthermia on Normal Canine Liver

    International Nuclear Information System (INIS)

    Suh, Chang Ok; Loh, John J. K.; Seong, Jin Sil

    1991-01-01

    In order to assess the effects of radiofrequency-induced local hyperthermia on the normal liver, histopathologic findings and biochemical changes after localized hyperthermia in canine liver were studied. Hyperthermia was externally administered using the Thermotron RF-8 (Yamamoto Vinyter Co., Japan; Capacitive type heating machine) with parallel opposed electrodes. Thirteen dogs were used and allocated into one control group (N=3) and two treatment groups according to the treatment temperature. Group I (N=5) was heated with 42.5±0.5.deg.C for 30 minutes, and Group(N=5) was heated with 45±0.5.deg.C for 15-30 minutes. Samples of liver tissue were obtained through a needle biopsy immediately after hyperthermia and 7, 14 and 28 days after treatment and examined for SGOT, SGPT and alkaline phosphatase. Although SGOT and SGPT were elevated after hyperthermia in both groups (three of five in each group), there was no liver cell necrosis or hyperthermia related mortality in Group I. A hydropic swelling of hepatocytes was prominent histologic finding. Hyperthermia with 45.deg.C for 30 minutes was fatal and showed extensive liver cell necrosis. In conclusion, liver damage day heat of 42.5±0.5.deg.C for 30 minutes is reversible, and liver damage by heat of 45±0.5.deg.C for 30 minutes can be fatal or irreversible. However, these results cannot be applied directly to human trial. Therefore, in order to apply hyperthermic treatment on human liver tumor safely, close observation of temperature with proper thermometry is mandatory. Hyperthermic treatment should be confined to the tumor area while sparing a normal liver as much as possible

  7. Energy Saving Glass Lamination via Selective Radio-Frequency Heating

    Energy Technology Data Exchange (ETDEWEB)

    Shulman, Holly S.; Allan, Shawn M.

    2009-11-11

    This Inventions and Innovations program supported the technical and commercial research and development needed to elevate Ceralink's energy saving process for flat glass lamination from bench scale to a self-supporting technology with significant potential for growth. Radio-frequency heating was any un-explored option for laminating glass prior to this program. With significant commercial success through time and energy savings in the wood, paper, and plastics industries, RF heating was found to have significant promise for the energy intensive glass lamination industry. A major technical goal of the program was to demonstrate RF lamination across a wide range of laminate sizes and materials. This was successfully accomplished, dispelling many skeptics' concerns about the abilities of the technology. Ceralink laminated panels up to 2 ft x 3 ft, with four sets processed simultaneously, in a 3 minute cycle. All major categories of interlayer materials were found to work with RF lamination. In addition to laminating glass, other materials including photovoltaic silicon solar cells, light emitting diodes, metallized glass, plastics (acrylic and polycarbonate), and ceramics (alumina) were found compatible with the RF process. This opens up a wide range of commercial opportunities beyond the initially targeted automotive industry. The dramatic energy savings reported for RF lamination at the bench scale were found to be maintained through the scale up of the process. Even at 2 ft x 3 ft panel sizes, energy savings are estimated to be at least 90% compared to autoclaving or vacuum lamination. With targeted promotion through conference presentations, press releases and internet presence, RF lamination has gained significant attention, drawing large audiences at American Ceramic Society meetings. The commercialization success of the project includes the establishment of a revenue-generating business model for providing process development and demonstrations for

  8. Experimental study of a high intensity radio-frequency cooler

    Directory of Open Access Journals (Sweden)

    Ramzi Boussaid

    2015-07-01

    Full Text Available Within the framework of the DESIR/SPIRAL-2 project, a radio-frequency quadrupole cooler named SHIRaC has been studied. SHIRaC is a key device of SPIRAL-2, designed to enhance the beam quality required by DESIR. The preliminary study and development of this device has been carried out at Laboratoire de Physique Corpusculaire de CAEN (LPC Caen, France. The goal of this paper is to present the experimental studies conducted on a SHIRaC prototype. The main peculiarity of this cooler is its efficient handling and cooling of ion beams with currents going up as high as 1  μA which has never before been achieved in any of the previous coolers. Much effort has been made lately into these studies for development of appropriate optics, vacuum and rf systems which allow cooling of beams of large emittance (∼80π  mm mrad and high current. The dependencies of SHIRaC’s transmission and the cooled beam parameters in terms of geometrical transverse emittance and the longitudinal energy spread have also been discussed. Investigation of beam purity at optimum cooling condition has also been done. Results from the experiments indicate that an emittance reduction of less than 2.5π  mm mrad and a longitudinal energy spread reduction of less than 4 eV are obtained with more than 70% of ion transmission. The emittance is at expected values whereas the energy spread is not.

  9. MR images of radiofrequency lesions following ventrolateral thalamotomy

    Energy Technology Data Exchange (ETDEWEB)

    Shinno, Kiyohito [Tokushima Univ. (Japan). School of Medicine

    1992-10-01

    In 14 patients with Parkinson's disease and one with intension tremor, thalamotomy lesions were examined with magnetic resonance (MR) imaging at acute (day 3), subacute (day 14), and chronic (2 months to 1 year) stages after surgery. Standard radiofrequency lesion-making was repeated up to a complete abolition of motor symptoms. At acute stage, three or four distinct zones of the thalamus were seen on MR images: the central and third zones were of low signal on T1- and high signal on T2-weighted images; and the second zone was isointense on T1- and of low signal on T2-weighted images. The out-most zone was of high signal on T2-weighted images, but not noticeable on T1-weighted images. MR appearances at subacute stage showed hyperintensity on T1- and T2-weighted images for both the central and third zones. The second zone became smaller and fainter, although there was no signal change. The out-most zone became much smaller on T2-weighted images and was invisible on T1-weighted images. At subacute stage, T2-weighted images showed two distinct layers: the inner layer was of high signal and the outer layer was of low signal. T1-weighted imaging showed mixed isointensity and hyperintensity. At chronic stage one year after surgery, the lesions became small, round cystic with low signal on T1- and either low or high signal on T2-weighted images. At acute stage, the central, second, and third zones seemed reflect a small area of needle destruction composed of blood and edema, a layer of coagulation necrosis, and a layer of hemorrhagic colliquation necrosis with edema, respectively. Water content increased due to edema at acute stage; and hemoglobin changed paramagentic forms in association with diminution of edema in subacute or chronic stage.(N.K.).

  10. Determination of lesion size by ultrasound during radiofrequency catheter ablation.

    Science.gov (United States)

    Awad, S; Eick, O

    2003-01-01

    The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.

  11. Outcome after Radiofrequency Ablation of Sarcoma Lung Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Koelblinger, Claus, E-mail: claus.koelblinger@bhs.at [KH Barmherzige Schwestern Ried, Department of Radiology (Austria); Strauss, Sandra, E-mail: s.strauss@ucl.ac.uk [UCL and UCLH, Department of Medical Oncology (United Kingdom); Gillams, Alice, E-mail: alliesorting@gmail.com [The London Clinic, Department of Radiology (United Kingdom)

    2013-05-14

    PurposeResection is the mainstay of management in patients with sarcoma lung metastases, but there is a limit to how many resections can be performed. Some patients with inoperable disease have small-volume lung metastases that are amenable to thermal ablation. We report our results after radiofrequency ablation (RFA).MethodsThis is a retrospective study of patients treated from 2007 to 2012 in whom the intention was to treat all sites of disease and who had a minimum CT follow-up of 4 months. Treatment was performed under general anesthesia/conscious sedation using cool-tip RFA. Follow-up CT scans were analyzed for local control. Primary tumor type, location, grade, disease-free interval, prior resection/chemotherapy, number and size of lung tumors, uni- or bilateral disease, complications, and overall and progression-free survival were recorded.ResultsTwenty-two patients [15 women; median age 48 (range 10–78) years] with 55 lung metastases were treated in 30 sessions. Mean and median tumor size and initial number were 0.9 cm and 0.7 (range 0.5–2) cm, and 2.5 and 1 (1–7) respectively. Median CT and clinical follow-up were 12 (4–54) and 20 (8–63) months, respectively. Primary local control rate was 52 of 55 (95 %). There were 2 of 30 (6.6 %) Common Terminology Criteria grade 3 complications with no long-term sequelae. Mean (median not reached) and 2- and 3-year overall survival were 51 months, and 94 and 85 %. Median and 1- and 2-year progression-free survival were 12 months, and 53 and 23 %. Prior disease-free interval was the only significant factor to affect overall survival.ConclusionRFA is a safe and effective treatment for patients with small-volume sarcoma metastases.

  12. Comparison of GSM Modulated and CW Radiofrequency Radiation on Cells

    International Nuclear Information System (INIS)

    Pavicic, I.; Marjanovic, A.M.; Trosic, I.

    2011-01-01

    The aim of our study was to evaluate and compare effect of global system of mobile (GSM) modulation and continuous wave (CW) radiofrequency radiation (RF) on proliferation ability and viability of V79 Chinese hamster lung cells. Previously prepared samples of cells in culture were exposed for 1, 2 and 3 hours both to 915 MHz GSM modulated and to 935 MHz CW RF field in gigahertz transversal electromagnetic mode cell (GTEM-cell). Electric field strength for cells exposed to GSM modulation was set at 10 V/m and for CW exposed cells was 8.2 V/m. Average specific absorption rate (SAR) was calculated to be for GSM 0.23 W/kg and for CW 0.12 W/kg. V79 samples were plated in concentration of 1x10 4 cells/mL. Cell proliferation was determined by cell counts for each hour of exposure during five post-exposure days. Trypan blue exclusion test was used to determine cell viability. In comparison to control cell samples, proliferation of GSM irradiated cells showed significant decrease after 3 hours of exposure on the second and third post-exposure day. CW exposed cell samples showed significant decrease after 3 hours of exposure on the third post-exposure day. Viability of GSM and CW exposed cells did not significantly differ from matched control cell samples. Both applied RF fields have shown similar effect on cell culture growth, and cell viability of V79 cell line. In addition, applied GSM modulated RF radiation demonstrate bigger influence on proliferation of cells. (author)

  13. Percutaneous radiofrequency ablation for malignant liver tumours in challenging locations

    International Nuclear Information System (INIS)

    Kelogrigoris, Michalis; Laspas, Fotios; Kyrkou, Katerina; Stathopoulos, Kostas; Georgiadou, Vithleem; Thanos, Loucas

    2012-01-01

    To evaluate the treatment results of radiofrequency ablation (RFA) for primary and metastatic malignant liver tumours in challenging locations and also to present the treatment strategy that was used in these cases.From January 2007 to January 2010, we performed CT-guided RFA on 528 lesions in 402 patients (265 men and 137 women; mean age 65.1 years, range 19–82 years) with liver tumours (primary and metastatic) of which 98 lesions in 84 patients (55 men and 29 women; mean age 67.8 years, range 33–82 years) were located in challenging locations, defined as less than 5 mm from a large vessel or an extrahepatic organ (heart, lung, gall bladder, right kidney or gastrointestinal tract). The sizes of the tumours ranged 1.5–6 cm. We used two different RFA systems with an expandable needle electrode (RITA; Rita Medical Systems, Inc, Mountain View, CA, USA and MIRAS; Invatec S.r.l., Roncadelle, Italy).The tumours were considered as ablated completely if no viability was found on dual-phase dynamic contrast-enhanced CT at 1 month after RFA. Complete ablation was obtained in 89.7% (88/98) of the high-risk located lesions, while 10 (10.3%) of the lesions were managed with repeated RFA because of tumour residue. The 1-, 2- and 3-year survival rates were 82.6, 67.3 and 54.1%, respectively. Minor complications occurred in eight of the 84 patients (9.5%), including small sub-capsular haematoma in four, small pleural effusion in three and partial liver infarction in one. Local tumour progression rate was 9.2% (9/98). RFA is a safe and effective method of treatment of primary and metastatic liver tumours even located in challenging locations when performed by a well-trained and experienced interventional radiologist.

  14. Radiofrequency exposure in the Neonatal Medium Care Unit

    Energy Technology Data Exchange (ETDEWEB)

    Calvente, I. [Unit Research Support of the San Cecilio University Hospital, Biosanitary Institute of Granada (ibs.GRANADA), University Hospitals of Granada/University of Granada, Granada (Spain); Department of Radiology and Physical Medicine, School of Medicine, University of Granada, Av. de la Investigación, 11, torre A, planta 11, 18016 Granada (Spain); Vázquez-Pérez, A. [Department of Pediatrics, University of Granada (Spain); Fernández, M.F. [Unit Research Support of the San Cecilio University Hospital, Biosanitary Institute of Granada (ibs.GRANADA), University Hospitals of Granada/University of Granada, Granada (Spain); Department of Radiology and Physical Medicine, School of Medicine, University of Granada, Av. de la Investigación, 11, torre A, planta 11, 18016 Granada (Spain); CIBER en Epidemiología y Salud Pública (CIBERESP) (Spain); Núñez, M.I., E-mail: isabeln@ugr.es [Unit Research Support of the San Cecilio University Hospital, Biosanitary Institute of Granada (ibs.GRANADA), University Hospitals of Granada/University of Granada, Granada (Spain); Department of Radiology and Physical Medicine, School of Medicine, University of Granada, Av. de la Investigación, 11, torre A, planta 11, 18016 Granada (Spain); Biopathology and Regenerative Medicine Institute (IBIMER), University of Granada (Spain); CIBER en Epidemiología y Salud Pública (CIBERESP) (Spain); Múñoz-Hoyos, A. [Department of Pediatrics, University of Granada (Spain)

    2017-01-15

    The aims of this study were to characterize electromagnetic fields of radiofrequency (RF-EMF) levels generated in a Neonatal Medium Care Unit and to analyze RF-EMF levels inside unit’s incubators. Spot and long-term measurements were made with a dosimeter. The spot measurement mean was 1.51±0.48 V/m. Higher values were found in the proximity to the window and to the incubator evaluated. Mean field strength for the entire period of 17 h was 0.81 (±0.07) V/m and the maximum value was 1.58 V/m for long-term RF-EMF measurements in the incubator. Values found during the night period were higher than those found during the day period. It is important to consider RF-EMF exposure levels in neonatal care units, due to some evidence of adverse health effects found in children and adults. Characterization of RF-EMF exposure may be important to further investigate the mechanisms and underlying effects of electromagnetic fields (EMF) on infant health. A prudent avoidance strategy should be adopted because newborns are at a vulnerable stage of development and the actual impact of EMF on premature infants is unknown. - Highlights: • The increasing use of RF-EMF suggests an urgent need for more research in this field. • Health consequences of RF-EMF exposure on infants are not well known. • Description of RF-EMF exposure is vital in further study mechanisms on infant health. • Considering newborns vulnerability, it is wise to adopt a prudent avoidance strategy.

  15. Outcome after Radiofrequency Ablation of Sarcoma Lung Metastases

    International Nuclear Information System (INIS)

    Koelblinger, Claus; Strauss, Sandra; Gillams, Alice

    2014-01-01

    PurposeResection is the mainstay of management in patients with sarcoma lung metastases, but there is a limit to how many resections can be performed. Some patients with inoperable disease have small-volume lung metastases that are amenable to thermal ablation. We report our results after radiofrequency ablation (RFA).MethodsThis is a retrospective study of patients treated from 2007 to 2012 in whom the intention was to treat all sites of disease and who had a minimum CT follow-up of 4 months. Treatment was performed under general anesthesia/conscious sedation using cool-tip RFA. Follow-up CT scans were analyzed for local control. Primary tumor type, location, grade, disease-free interval, prior resection/chemotherapy, number and size of lung tumors, uni- or bilateral disease, complications, and overall and progression-free survival were recorded.ResultsTwenty-two patients [15 women; median age 48 (range 10–78) years] with 55 lung metastases were treated in 30 sessions. Mean and median tumor size and initial number were 0.9 cm and 0.7 (range 0.5–2) cm, and 2.5 and 1 (1–7) respectively. Median CT and clinical follow-up were 12 (4–54) and 20 (8–63) months, respectively. Primary local control rate was 52 of 55 (95 %). There were 2 of 30 (6.6 %) Common Terminology Criteria grade 3 complications with no long-term sequelae. Mean (median not reached) and 2- and 3-year overall survival were 51 months, and 94 and 85 %. Median and 1- and 2-year progression-free survival were 12 months, and 53 and 23 %. Prior disease-free interval was the only significant factor to affect overall survival.ConclusionRFA is a safe and effective treatment for patients with small-volume sarcoma metastases

  16. Radio-frequency quadrupole: a new linear accelerator

    International Nuclear Information System (INIS)

    Stokes, R.H.; Wangler, T.P.; Crandall, K.R.

    1981-01-01

    In many Laboratories, great emphasis now is placed on the development of linear accelerators with very large ion currents. To achieve this goal, a primary concern must be the low-velocity part of the accelerator, where the current limit is determined and where most of the emittance growth occurs. The use of magnetic focusing, the conflicting requirements in the choice of linac frequency, and the limitations of high-voltage dc injectors, have tended to produce low-velocity designs that limit overall performance. The radio-frequency quadrupole (RFQ) linear accelerator, invented in the Soviet Union and developed at Los Alamos, offers an attractive solution to many of these low-velocity problems. In the RFQ, the use of RF electric fields for radial focusing, combined with special programming of the bunching, allows high-current dc beams to be captured and accelerated with only small beam loss and low radial emittance growth. Advantages of the RFQ linac include a low injection energy (20 to 50 keV for protons) and a final energy high enough so the beam can be further accelerated with high efficiency in a Wideroee or Alvarez linac. These properties have been confirmed at Los Alamos in a highly successful experimental test performed during the past year. The success of this test and the advances in RFQ design procedures have led to the adoption of this linac for a wide range of applications. The beam-dynamics parameters of three RFQ systems are described. These are the final design for the protytype test of the Fusion Materials Irradiation Test (FMIT) accelerator, the final design for the prototype test of the Pion Generator for Medical Irradiations (PIGMI), and an improved low-velocity linac for heavy ion fusion

  17. Radiofrequency exposure from wireless LANs utilizing Wi-Fi technology.

    Science.gov (United States)

    Foster, Kenneth R

    2007-03-01

    This survey measured radiofrequency (RF) fields from wireless local area networks (WLANs) using Wi-Fi technology against a background of RF fields in the environment over the frequency range 75 MHz-3 GHz. A total of 356 measurements were conducted at 55 sites (including private residences, commercial spaces, health care and educational institutions, and other public spaces) in four countries (U.S., France, Germany, Sweden). Measurements were conducted under conditions that would result in the higher end of exposures from such systems. Where possible, measurements were conducted in public spaces as close as practical to the Wi-Fi access points. Additional measurements were conducted at a distance of approximately 1 m from a laptop while it was uploading and downloading large files to the WLAN. This distance was chosen to allow a useful comparison of fields in the far-field of the antenna in the laptop, and give a representative measure of the exposure that a bystander might receive from the laptop. The exposure to the user, particularly if the antenna of the client card were placed against his or her body, would require different measurement techniques beyond the scope of this study. In all cases, the measured Wi-Fi signal levels were very far below international exposure limits (IEEE C95.1-2005 and ICNIRP) and in nearly all cases far below other RF signals in the same environments. An discusses technical aspects of the IEEE 802.11 standard on which WLANs operate that are relevant to determining the levels of RF energy exposure from WLANs. Important limiting factors are the low operating power of client cards and access points, and the low duty cycle of transmission that normally characterizes their operation.

  18. Radiofrequency Exposure Amongst Employees of Mobile Network Operators and Broadcasters.

    Science.gov (United States)

    Litchfield, Ian; van Tongeren, Martie; Sorahan, Tom

    2017-06-15

    Little is known about personal exposure to radiofrequency (RF) fields amongst employees in the telecommunications industry responsible for installing and maintaining transmitters. IARC classified RF exposure as a possible carcinogen, although evidence from occupational studies was judged to be inadequate. Hence, there is a need for improved evidence of any potentially adverse health effects amongst the workforce occupationally exposed to RF radiation. In this study, results are presented from an exposure survey using data from personal monitors used by employees in the broadcasting and telecommunication industries of the UK. These data were supplemented by spot measurements using broadband survey metres and information on daily work activities provided by employee questionnaires. The sets of real-time personal data were categorised by four types of site determined by the highest powered antenna present (high, medium or low power and ground-level sites). For measurements gathered at each type of site, the root mean square and a series of box plots were produced. Results from the daily activities diaries suggested that riggers working for radio and television broadcasters were exposed to much longer periods as compared to colleagues working for mobile operators. Combining the results from the measurements and daily activity diaries clearly demonstrate that exposures were highest for riggers working for broadcasting sites. This study demonstrates that it is feasible to carry out exposure surveys within these populations that will provide reliable estimates of exposure that can be used for epidemiological studies of occupational groups exposed to RF fields. © The Author 2016. Published by Oxford University Press.

  19. Personal radiofrequency electromagnetic field exposure measurements in Swiss adolescents.

    Science.gov (United States)

    Roser, Katharina; Schoeni, Anna; Struchen, Benjamin; Zahner, Marco; Eeftens, Marloes; Fröhlich, Jürg; Röösli, Martin

    2017-02-01

    Adolescents belong to the heaviest users of wireless communication devices, but little is known about their personal exposure to radiofrequency electromagnetic fields (RF-EMF). The aim of this paper is to describe personal RF-EMF exposure of Swiss adolescents and evaluate exposure relevant factors. Furthermore, personal measurements were used to estimate average contributions of various sources to the total absorbed RF-EMF dose of the brain and the whole body. Personal exposure was measured using a portable RF-EMF measurement device (ExpoM-RF) measuring 13 frequency bands ranging from 470 to 3600MHz. The participants carried the device for three consecutive days and kept a time-activity diary. In total, 90 adolescents aged 13 to 17years participated in the study conducted between May 2013 and April 2014. In addition, personal measurement values were combined with dose calculations for the use of wireless communication devices to quantify the contribution of various RF-EMF sources to the daily RF-EMF dose of adolescents. Main contributors to the total personal RF-EMF measurements of 63.2μW/m 2 (0.15V/m) were exposures from mobile phones (67.2%) and from mobile phone base stations (19.8%). WLAN at school and at home had little impact on the personal measurements (WLAN accounted for 3.5% of total personal measurements). According to the dose calculations, exposure from environmental sources (broadcast transmitters, mobile phone base stations, cordless phone base stations, WLAN access points, and mobile phones in the surroundings) contributed on average 6.0% to the brain dose and 9.0% to the whole-body dose. RF-EMF exposure of adolescents is dominated by their own mobile phone use. Environmental sources such as mobile phone base stations play a minor role. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Instabilities and growing waves: power absorbed or generated by the various excited modes in a plasma; Instabilites et ondes croissantes: puissance absorbee - ou engendree - par les differents modes excites dans un plasma

    Energy Technology Data Exchange (ETDEWEB)

    Rolland, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-05-01

    The character, stable or unstable, of a medium can be deduced from the behavior of an ideal model of a semi-infinite medium which is subjected to an excitation only at the boundary. A new analytic method is used to solve this problem. The results obtained show a connection between the character of the medium and certain properties of the dispersion equation, and agree with those derived from other methods. Then, the energy exchange between a medium and a source of excitation is investigated. In order to include the case of growing waves associated with convective instabilities, this problem is treated in the context of the wave packet theory. We find that - even in the absence of collisions - there still is a power exchange. Thus a connexion can be established with the kinematic theories of growing waves and the modes generating power can be found. Moreover, the power absorbed by spatial dispersion is found to be identical with that due to Landau's effect for long waves. This confirms the kinematic character of the latter and bridges a gap between macroscopic and microscopic theories. (author) [French] Le caractere, stable ou instable, d'un milieu peut etre deduit du comportement d'un milieu semi-indefini soumis a une excitation a la frontiere. Une nouvelle methode analytique est developpee pour resoudre ce probleme. Les resultats obtenus montrent une connexion entre le comportement du milieu et certaines proprietes de l'equation de dispersion, et generalisent les resultats obtenus par d'autres methodes. On etudie ensuite les echanges d'energie entre un milieu et une source d'excitation. Pour inclure le cas des ondes croissantes associees aux instabilites convectives, on traite ce probleme dans le cadre de la theorie du paquet d'ondes. On trouve que meme en l'absence de collisions, la puissance echangee n'est pas nulle. Ceci permet d'etablir une connexion avec les theories cinematiques des ondes croissantes, tout en precisant quels sont les modes generateurs d

  1. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, J; Low, D [University of California, Los Angeles, Los Angeles, CA (United States); Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States); Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J [ViewRay, Inc., Oakwood Village, OH (United States)

    2016-06-15

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was

  2. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    International Nuclear Information System (INIS)

    Lamb, J; Low, D; Mutic, S; Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J

    2016-01-01

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was

  3. Ultrasound-guided radiofrequency ablation of thyroid gland: a preliminary study in dogs

    International Nuclear Information System (INIS)

    Choi, Ji Won; Yoo, Seung Min; Kwak, Seo Hyun

    2005-01-01

    The purpose of this study was to evaluate the possibility of using radiofrequency ablation as the treatment modality for the benign or malignant thyroid nodules in humans. Therefore, we examined the results of using radiofrequency ablation on the thyroid glands in dogs, in respect of the extent of the ablated tissue and the complications. Five dogs (10 lobes of the thyroid glands) were included in this study. US-guided radiofrequency ablation was undertaken with a 10 mm, uncovered 17 gauge cool-tip needle. The power and duration was 20 wattage and 1 minute in five thyroid lobes (group 1) and 20 wattage and 2 minutes in another 5 thyroid lobes (group 2). The ultrasound scans and the pre-and post-enhancement CT scans were undertaken before and immediately after the procedures, and at 24 hours, 72 hours and 1 week later. The US and CT findings of the ablated tissue and complications were evaluated. Blood sampling was done at the pre-procedure time and 1 week later for evaluating the functional status of the thyroid gland. Laryngoscopy was done at the pre-procedure and post-procedure times, and at 24 hours, 72 hours and 1 week later for the evaluation of any recurrent laryngeal nerve palsy. The echo pattern of the ablated thyroid gland at immediately after the radiofrequency ablation appeared as poorly marginated and hyperechoic. On the US obtained 24 hours after radiofrequency ablation, the echo pattern of the ablated thyroid gland was hypoechoic. The maximum diameters after RFA were 9.4 ρ 0.5 mm in group I and 11.4 ρ 0.5 mm in group II. The pre-enhanced CT scan taken at immediately after the radiofrequency ablation showed ill defined hypodense areas in the ablated thyroid gland. Differentiation between the normal and abnormal portions of the thyroid gland was difficult on the contrast enhanced CT scan. Complications induced by radiofrequency ablation were one recurrent laryngeal nerve palsy, two perforations of esophagus and five thickenings of the esophageal wall

  4. Experimental and clinical studies with radiofrequency-induced thermal endometrial ablation for functional menorrhagia

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, J.H.; Lewis, B.V.; Prior, M.V.; Roberts, T. (Watford General Hospital, Herts (England))

    1990-11-01

    A method of ablating the endometrium has been introduced into clinical practice that uses radiofrequency electromagnetic energy to heat the endometrium, using a probe inserted through the cervix. Preliminary studies suggest that over 80% of patients treated will develop either amenorrhea or a significant reduction in flow. The advantages of radiofrequency endometrial ablation over laser ablation or resection are the avoidance of intravascular fluid absorption, simplicity (no special operative hysteroscopic skills are required), speed of operation, and reduced cost compared with the Nd:YAG laser. In this paper, we describe the experimental studies performed during development of this new technique.

  5. Pulsed radiofrequency microwave fields around a quadrupole particle accelerator: measurement and safety evaluation

    International Nuclear Information System (INIS)

    Sachdev, R.N.; Swarup, G.; Rajan, K.K.; Joseph, L.

    1996-01-01

    Pulsed radiofrequency microwave radiation (RFMR) fields occur during the use of high power microwaves in plasma heating in fusion research, plasma and solid state diagnostics, particle accelerators and colliders, pump sources in lasers, material processing as well as in high power radars. This paper describes the experimental work done at Trombay for measurement of pulsed RFMR fields in the working area of a radiofrequency quadrupole (RFQ) accelerator with the use of a meter calibrated in continuous field and interprets the observed fields in the light of existing protection criteria for pulsed RFMR fields. (author)

  6. Tunable radio-frequency photonic filter based on an actively mode-locked fiber laser.

    Science.gov (United States)

    Ortigosa-Blanch, A; Mora, J; Capmany, J; Ortega, B; Pastor, D

    2006-03-15

    We propose the use of an actively mode-locked fiber laser as a multitap optical source for a microwave photonic filter. The fiber laser provides multiple optical taps with an optical frequency separation equal to the external driving radio-frequency signal of the laser that governs its repetition rate. All the optical taps show equal polarization and an overall Gaussian apodization, which reduces the sidelobes. We demonstrate continuous tunability of the filter by changing the external driving radio-frequency signal of the laser, which shows good fine tunability in the operating range of the laser from 5 to 10 GHz.

  7. Radiofrequency ablation of fast ventricular tachycardia causing an ICD storm in an infant with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ergul, Yakup; Ozyilmaz, Isa; Bilici, Meki; Ozturk, Erkut; Haydin, Sertaç; Guzeltas, Alper

    2018-04-01

    An implantable cardioverter defibrillator (ICD) storm involves very frequent arrhythmia episodes and ICD shocks, and it is associated with poor short-term and long-term prognosis. Radiofrequency catheter ablation can be used as an effective rescue treatment for patients with an ICD storm. To our knowledge, this is the first report of an infant with hypertrophic cardiomyopathy presenting with an ICD storm and undergoing successful radiofrequency catheter ablation salvage treatment for the fast left posterior fascicular ventricular tachycardia. © 2017 Wiley Periodicals, Inc.

  8. Thermistor guided radiofrequency ablation of atrial insertion sites in patients with accessory pathways.

    Science.gov (United States)

    Tracy, C M; Moore, H J; Solomon, A J; Rodak, D J; Fletcher, R D

    1995-11-01

    Radiofrequency ablation has gained acceptance in the treatment of patients with symptomatic Wolff-Parkinson-White syndrome. The purpose of this study was to characterize the relation between temperature and other electroconductive parameters in patients undergoing atrial insertion accessory pathway ablation utilizing a thermistor equipped catheter. The mean temperature and power at sites of atrial insertion ablation are lower than has been previously associated with creation of radiofrequency lesions in the ventricle. While high cavitary blood flow in the atrium may result in cooling, the thinner atrial tissue may require less energy to achieve adequate heating than ventricular myocardium.

  9. Ultrasound-guided radiofrequency ablation of thyroid gland: a preliminary study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Won; Yoo, Seung Min [College of Medicine, Chungang University, Seoul, (Korea, Republic of); Kwak, Seo Hyun [Seoul Veterans Hospital, Seoul (Korea, Republic of)

    2005-07-15

    The purpose of this study was to evaluate the possibility of using radiofrequency ablation as the treatment modality for the benign or malignant thyroid nodules in humans. Therefore, we examined the results of using radiofrequency ablation on the thyroid glands in dogs, in respect of the extent of the ablated tissue and the complications. Five dogs (10 lobes of the thyroid glands) were included in this study. US-guided radiofrequency ablation was undertaken with a 10 mm, uncovered 17 gauge cool-tip needle. The power and duration was 20 wattage and 1 minute in five thyroid lobes (group 1) and 20 wattage and 2 minutes in another 5 thyroid lobes (group 2). The ultrasound scans and the pre-and post-enhancement CT scans were undertaken before and immediately after the procedures, and at 24 hours, 72 hours and 1 week later. The US and CT findings of the ablated tissue and complications were evaluated. Blood sampling was done at the pre-procedure time and 1 week later for evaluating the functional status of the thyroid gland. Laryngoscopy was done at the pre-procedure and post-procedure times, and at 24 hours, 72 hours and 1 week later for the evaluation of any recurrent laryngeal nerve palsy. The echo pattern of the ablated thyroid gland at immediately after the radiofrequency ablation appeared as poorly marginated and hyperechoic. On the US obtained 24 hours after radiofrequency ablation, the echo pattern of the ablated thyroid gland was hypoechoic. The maximum diameters after RFA were 9.4 {rho} 0.5 mm in group I and 11.4 {rho} 0.5 mm in group II. The pre-enhanced CT scan taken at immediately after the radiofrequency ablation showed ill defined hypodense areas in the ablated thyroid gland. Differentiation between the normal and abnormal portions of the thyroid gland was difficult on the contrast enhanced CT scan. Complications induced by radiofrequency ablation were one recurrent laryngeal nerve palsy, two perforations of esophagus and five thickenings of the esophageal

  10. Aplicación de la técnica PIXE (Particle Induced X-Ray Emision a la caracterización no destructiva de una pieza de ajuar funerario (siglo I d.c. procedente de una excavación arqueológica (antiguo Hospital de las Cinco Llagas, Sevilla

    Directory of Open Access Journals (Sweden)

    Enrique Magariño, M. E.

    2002-12-01

    Full Text Available In this work, a non-destructive characterization of a burial-sample object dated S.I. a.C. (ring with an incrusted material coming from an archaeological excavation (former Hospital de las Cinco Llagas, Sevilla has been carried out. The glass or ceramic nature of this sample was unknown. Several non-destructive techniques have been applied: optical microscopy, SEM-EDX, XRD and XRF. In this particular case, the technique Particle Induced X-ray Emision (PIXE has been also applied. PIXE allows to obtain a fast information concerning chemical composition of trace elements using the object directly. The study of this interesting object indicates the extreme quality and accurance of the engrave observed on its surface, for instance a long-legged bird and a palm leaf despite their reduced size. Relief effects have been observed in the engrave using the own constitution of this particular material. The XRD phase analysis demonstrates that crystalline quartz as single phase constitutes the incrusted material of the ring considered as a gem: blue quartz. The chemical composition obtained from XRF analysis confirm the XRD result, with Si and O as main elements, although there are minoritary elements such as Ca and Fe (< 1,5 %, Na and Al (ca. 0,3 %. Other elements, such as Cl, K and P were detected in similar percentages (0.2-0,25 %, besides Mg and S (less than 0,08 %. However, the application of the PIXE technique based on ion beam analysis to this material allowed to demonstrate the presence of Ti and V, probably as ions in the quartz crystal structure which constitutes the gem. This experimental fact would then explain the blue colour observed in the gem. Consequently, PIXE as a non-destructive technique allows to find an important chemical difference between zones of the same object. There are some advantages, first of all that these chemical differences can not be accurately observed using other conventional techniques and secondly, the analysis is

  11. Calculation of the shock-wave in the region close to an underground nuclear explosion (method Cades); Calcul de l'onde de choc en zone proche d'une explosion nucleaire souterraine (methode cades)

    Energy Technology Data Exchange (ETDEWEB)

    Supiot, F; Brugies, J [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    The outline of a method is presented for calculating the characteristics of a shock wave produced by an underground nuclear explosion (pressure, wave velocity, velocity of the medium, energy left in the medium by the shock, etc.). By means of an application to a granitic medium and of a comparison with results obtained during French nuclear explosions, it has been possible to show the good agreement existing between the calculations and the experimental results. The advantages of such a method for studying the industrial applications of underground nuclear explosions are stressed. (authors) [French] On expose les grandes lignes d'une methode de calcul des caracteristiques de l'onde de choc issue d'une explosion nucleaire souterraine (pression, vitesse de l'onde, vitesse du milieu, energie deposee par le choc dans le milieu...). Une application a un milieu granitique et une comparaison aux resultats obtenus au cours d'explosions nucleaires francaises permet de montrer la bonne concordance entre le calcul et les resultats experimentaux. On souligne l'interet d'une telle, methode pour l'etude d'applications industrielles des explosions nucleaires souterraines. (auteurs)

  12. Phase-shift analysis of pion-nucleon elastic scattering below 1.6 GeV; Analyse en ondes partielles de la diffusion elastique meson {pi} - nucleon au-dessous de 1.6 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Bareyre, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-06-01

    Experimental results of pion-nucleon elastic scattering below 1.6 GeV (total cross sections, angular distributions of elastic scattering and recoil nucleon polarizations) have been described by a partial wave analysis. This analysis has been developed, one energy at a time, with a method of least squares fits. A single solution is extracted by continuity with energy of the different solutions. Resonating behaviour has been clearly established for several partial waves. In addition to these important effects some phase shifts show rapid variations with energy. Present experimental situation does not permit to say whether these variations are due to experimental biases or to physical effects. (author) [French] Les resultats experimentaux de la diffusion elastique meson {pi} - nucleon au-dessous de 1.6 GeV (sections efficaces totales, distributions angulaires de diffusion elastique et de polarisation du nucleon de recul) sont decrits a l'aide d'une analyse en ondes partielles. Cette analyse est developpee energie par energie au moyen d'une methode d'ajustement en moindres carres. Un critere empirique de continuite des solutions en fonction de l'energie a permis d'isoler une solution unique. Des resonances sont clairement etablies pour plusieurs ondes partielles, ainsi que certains petits effets moins caracteristiques. Pour ceux-ci, la situation experimentale presente ne permet pas d'affirmer s'ils sont dus a des effets physiques ou a des biais experimentaux. (auteur)

  13. Osteoid osteoma: our experience using radio-frequency (RF) treatment

    International Nuclear Information System (INIS)

    Mastrantuono, Donato; Martorano, Domenico; Verna, Valter; Mancini, Andrea; Faletti, Carlo

    2005-01-01

    Purpose: To present the results of two years experience with a minimally invasive radio-frequency technique designed by our team in the treatment of osteoid osteoma. Materials and methods: A total of 21 osteoid osteoma patients (15 males, 6 females, age ranged 13 to 34 yrs) were treated between January 2001 and April 2003. Localization of the osteoid osteoma were the pelvis (n=1), the femur (n=12), the tibia (n=3), the foot (n=3), and the humerus (n=2). All patients underwent an X-ray examination, a CT scan and a bone Scintiscan. In the initial phase, a K-wire just slightly larger than the 17G needle electrode is positioned manually at the zenith of the target area under CT guidance and using an orthopaedic drill it is inserted at the centre of the nidus. A tailor-made metal sheath is inserted on the K-wire to create a tunnel through which the needle electrode can substitute the K-wire; at the same time, the electrode needle is positioned inside the lesion. The temperature of the exposed tip of the needle in 90 o C and duration of hyperthermia is 6 minutes on average. Once the procedure has been completed, a scan os performed to measure the density of treated site and this measurement is then used as an evolution index for the evaluation of the healing process during follow-up. Results: No serious complications were observed at follow-up. General anaesthesia was only required in the case with hip involvement; peripheral anaesthesia was used in all the other cases. Complete resolution of the pain was reported in all cases after a maximum of three week. Discussion and conclusions: After two years experience, we believe percutaneous RF treatment of osteoid osteoma to be the first choice technique when compared to traditional surgery due to the fact that it is almost non-invasive, quick, repeatable if need be and offers a high reduction in costs. Moreover early weight bearing is the norm and the patient is dismissed after only one day of hospitalization. The clinical

  14. Percutaneous radiofrequency ablation of inoperable primary lung cancer

    International Nuclear Information System (INIS)

    Kim, Seong Hyup; Jung, Gyoo Sik; Lee, Seung Ryong

    2004-01-01

    To present the initial experience of percutaneous radiofrequency ablation (RFA) of inoperable primary lung cancer, and to assess the technical feasibility and potential complications. Twenty patients with inoperable lung cancer underwent percutaneous RFA. Nineteen of 20 patients had stage III or IV non-small cell lung cancer, and the remaining one had stage I lung cancer with pulmonary dysfunction. The mean tumor size was 4.6 ± 0.4 cm (range, 1.8-8.4 cm). RFA was performed with a single (n = 18) or cluster (n = 2) cool-tip RF electrode and a generator under CT guidance using local anesthesia and conscious sedation. Twenty tumors were treated in 28 sessions. Patients were assessed by contrast-enhanced CT in all cases at 1 week, 1 month, and 3 months. Eleven patients received chemotherapy (n = 10) or radiotherapy (n = 1) after RFA. RFA was technically successful and well tolerated in all patients. Complete necrosis was attained in 7 lesions (35%), near complete (90-99%) necrosis in 10 lesions (50%), and partial (50-89%) necrosis in 3 lesions (15%). During the mean follow up of 202 days (21 to 481 days), tumor size was decreased in 13 patients, unchanged in 3, and increased in 4. In the latter four, additional RFA was performed. One patient underwent surgery three months after RFA and the histopathologic findings showed a large cavity with thin fibrotic wall suggestive of complete necrosis. During or after the procedure, pneumothorax (n = 10), moderate pain (n = 4), blood tinged sputum (n = 2), and pneumonia (n = 2) were developed. Chest tube drainage was required in only 1 patient due to severe pneumothorax. Other patients were managed conservatively. Seven patients died at 61 to 398 days (mean, 230 days) after RFA. The remaining 13 patients were alive 21 to 481 days (mean, 187 days) after RFA. RFA appears to be a technically feasible and relatively safe procedure for the cytoreductive treatment of inoperable, non-small cell lung cancer and warrants further

  15. Radiofrequency ablation of liver metastases; Radiofrequenzablation von Lebermetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, P.L.; Clasen, S.; Schmidt, D.; Wiskirchen, J.; Tepe, G.; Claussen, C.D. [Abt. fuer Radiologische Diagnostik, Eberhard-Karls-Univ. Tuebingen (Germany); Boss, A. [Abt. fuer Radiologische Diagnostik, Eberhard-Karls-Univ. Tuebingen (Germany); Sektion fuer Experimentelle Radiologie der Abt. fuer Radiologische Diagnostik, Eberhard-Karls-Univ. Tuebingen (Germany); Gouttefangeas, C. [Abt. Immunologie des Inst. fuer Zellbiologie, Eberhard-Karls-Univ. Tuebingen (Germany); Burkart, C. [Zentrum fuer gastroenterologische Onkologie der Medizinischen Klinik, Eberhard-Karls-Univ. Tuebingen (Germany)

    2004-04-01

    The liver is the second only to lymph nodes as the most common site of metastatic disease irrespective of the primary tumor. Up to 50% of all patients with malignant diseases will develop liver metastases with a significant morbidity and mortality. Although the surgical resection leads to an improvement of the survival time, only approximately 20% of the patients are eligible for surgical intervention. Radiofrequency (RF) ablation represents one of the most important alternatives as well as complementary methods for the therapy of liver metastases. RF ablation can lead in a selected patient group to a palliation or to an increased life expectancy. RF ablation appears either safer (vs. cryotherapy) or easier (vs. laser) or more effective (percutaneous ethanol instillation [PEI]), transarterial chemoembolisation [TACE] in comparison with other minimal invasive procedures. RF ablation can be performed percutaneously, laparoscopically or intraoperatively and may be combined with chemotherapy as well as with surgical resection. Permanent technical improvements of RF systems, a better understanding of the underlying electrophysiological principles and an interdisciplinary approach will lead to a prognosis improvement in patients with liver metastases. (orig.) [German] Die Leber ist unabhaengig vom Primaertumor nach den Lymphknoten die zweithaeufigste Lokalisation von Metastasen. Bis zu 50% aller Patienten mit malignen Erkrankungen werden im Verlauf ihrer Erkrankung Lebermetastasen entwickeln, die mit einer signifikanten Morbiditaet und Mortalitaet verbunden sind. Obwohl die chirurgische Resektion zu einer verlaengerten Ueberlebenszeit fuehrt, sind nur ca. 20% der Patienten fuer einen chirurgischen Eingriff geeignet. Die Radiofrequenz-(RF-)Ablation stellt derzeit eine der effektivsten Alternativen und komplementaeren Methoden bei der Therapie von Lebermetastasen dar. In einem selektierten Patientengut fuehrt die RF-Ablation ueber den palliativen Einsatz hinaus zu einer

  16. Radiofrequency ablation of pulmonary tumors near the diaphragm.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Gobara, H; Fujiwara, H; Sakurai, J; Matsui, Y; Mitsuhashi, T; Toyooka, S; Kanazawa, S

    To retrospectively evaluate the feasibility, safety, and efficacy of radiofrequency ablation (RFA) of lung tumors located near the diaphragm. A total of 26 patients (15 men, 11 women; mean age, 61.5 years±13.0 [SD]) with a total of 29 lung tumors near the diaphragm (i.e., distance<10mm) were included. Mean tumor diameter was 11.0mm±5.3 (SD) (range, 2-23mm). Efficacy of RFA, number of adverse events and number of adverse events with a grade≥3, based on the National Cancer Institute Common Terminology Criteria for Adverse Events, version 4.0, were compared between patients with lung tumors near the diaphragm and a control group of patients with more distally located lung tumors (i.e., distance≥10mm). RFA was technically feasible for all tumors near the diaphragm. Four grade 3 adverse events (1 pneumothorax requiring pleurodesis and 3 phrenic nerve injuries) were observed. No grade≥4 adverse events were reported. The median follow-up period for tumors near the diaphragm was 18.3 months. Local progression was observed 3.3 months after RFA in 1 tumor. The technique efficacy rates were 96.2% at 1 year and 96.2% at 2 years and were not different, from those observed in control subjects (186 tumors; P=0.839). Shoulder pain (P<0.001) and grade 1 pleural effusion (P<0.001) were more frequently observed in patients with lung tumor near the diaphragm. The rates of grade≥3 adverse events did not significantly differ between tumors near the diaphragm (4/26 sessions) and the controls (7/133 sessions) (P=0.083). RFA is a feasible and effective therapeutic option for lung tumors located near the diaphragm. However, it conveys a higher rate of shoulder pain and asymptomatic pleural effusion by comparison with more distant lung tumors. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  17. A trial of radiofrequency ablation for anal intraepithelial neoplasia.

    Science.gov (United States)

    Goldstone, Robert N; Hasan, Shirin R; Drury, Steven; Darragh, Teresa M; van Zante, Annemieke; Goldstone, Stephen E

    2017-03-01

    Radiofrequency ablation (RFA) effectively treats esophageal high-grade dysplasia, but its efficacy in treating anal canal high-grade squamous intraepithelial lesions (HSILs) is unsubstantiated. This prospective study assessed the safety and efficacy of applying hemi-circumferential RFA to anal canal HSIL. Twenty-one HIV-negative participants with HSIL occupying ≤ half the anal canal circumference were treated with hemi-circumferential anal canal RFA. Participants were assessed every 3 months for 12 months with high-resolution anoscopy; recurrence in the treatment zone was re-treated with focal RFA. Twenty-one participants with a mean of 1.7 lesions (range 1-4) enrolled and completed the trial. Six (29 %) participants had recurrent HSIL within the treated hemi-circumference within 1 year. Four participants (19 %) had persistence of an index lesion at 3 months. One (2.9 %) index HSIL persisted again at 12 months. No participants had more than two RFA treatments. KM curve-predicted HSIL-free survival within the treatment zone at 1 year was 76 % (95 % CI 52-89 %). Comparing the first 7 and last 14 participants, the predicted 1-year HSIL-free survivals are 43 % (95 % CI 10-73 %) and 93 % (95 % CI 59-99 %), respectively (p = 0.008), suggesting a learning curve with the treating physician. Multivariable analysis showed decreased recurrence in the last 14 participants (HR 0.02; 95 % CI 0.001-0.63) while increasing BMI increased recurrence (HR 1.43, 95 % CI 1.01-2.01). No participants had device or procedure-related serious adverse events, anal stricture, or heavy bleeding. Hemi-circumferential RFA yielded a high rate of anal HSIL eradication in HIV-negative patients at 1 year with minimal adverse events. Lesion persistence was probably related to incomplete initial ablation.

  18. Facial tightening with an advanced 4-MHz monopolar radiofrequency device.

    Science.gov (United States)

    Taub, Amy F; Tucker, Robert D; Palange, Andrea

    2012-11-01

    Over the past 10 years, radiofrequency (RF) technology has been utilized for nonablative treatments for the treatment of rhytides and skin laxity. This manuscript reviews the scientific background of collagen synthesis in vivo and in response to RF energy as well as a clinical study of 17 patients receiving a series of facial treatments with a 4-MHz monopolar RF (Pellevé, Ellman International, Inc, Oceanside, NY). Clinical methods, results, and a review of the literature for RF aesthetic treatments of the face are presented. Seventeen patients were treated in one site with 6 total treatments scheduled as follows: 1 session was performed every 15 days for 2 consecutive sessions, 1 session every month for 2 consecutive sessions, and 1 session every 2 months for 2 consecutive sessions. Both the treating physician and the patients via live viewing and comparison with baseline photographs performed assessment of results. Results are reported as averages across the 17 patients. Two weeks after the first treatment, patients noted an overall average of 25% to 30% improvement. Just before the last or sixth treatment, there was an average of 50% improvement noted by the physician, with patients ranking an average self-improvement of 48%. The treating physician rated average improvement of 46% compared with baseline, whereas the patients ranked average improvement of 30% compared with baseline at 1 year after treatment was initiated (6 months after the final treatment). Patients find this treatment to be very well tolerated, with minimal to no discomfort and no downtime or significant side effects. The Pellevé 4-MHz monopolar RF device is effective, safe, and very well tolerated for treating laxity, texture, and wrinkles of the skin without complication or discomfort. Evidence in the literature supports the scientific mechanism of action of acute collagen modification and continued neocollagenesis observed with the system. In this cohort, patients maintain approximately 50

  19. Length of Barrett's segment predicts failure of eradication in radiofrequency ablation for Barrett's esophagus: a retrospective cohort study.

    Science.gov (United States)

    Luckett, Tyler; Allamneni, Chaitanya; Cowley, Kevin; Eick, John; Gullick, Allison; Peter, Shajan

    2018-05-21

    We aim to investigate factors that may contribute to failure of eradication of dysplastic Barrett's Esophagus among patients undergoing radiofrequency ablation treatment. A retrospective review of patients undergoing radiofrequency ablation for treatment of Barrett's Esophagus was performed. Data analyzed included patient demographics, medical history, length of Barrett's Esophagus, number of radiofrequency ablation sessions, and histopathology. Subsets of patients achieving complete eradication were compared with those not achieving complete eradication. A total of 107 patients underwent radiofrequency ablation for Barrett's Esophagus, the majority white, overweight, and male. Before treatment, 63 patients had low-grade dysplasia, and 44 patients had high-grade dysplasia or carcinoma. Complete eradication was achieved in a majority of patients (57% for metaplasia, and 76.6% for dysplasia). Failure of eradication occurred in 15.7% of patients. The median number of radiofrequency ablation treatments in patients achieving complete eradication was 3 sessions, compared to 4 sessions for failure of eradication (p = 0.06). Barrett's esophagus length of more than 5 cm was predictive of failure of eradication (p Radiofrequency ablation for dysplastic Barrett's Esophagus is a proven and effective treatment modality, associated with a high rate of complete eradication. Our rates of eradication from a center starting an ablation program are comparable to previously published studies. Length of Barrett's segment > 5 cm was found to be predictive of failure of eradication in patients undergoing radiofrequency ablation.

  20. Bile Duct Disruption Following Radiofrequency Ablation: Successful Repair Using a Covered Stent

    International Nuclear Information System (INIS)

    Thompson, Philip M.; Hare, Christopher M.B.; Lees, William R.

    2004-01-01

    Persistent biliary leaks, whether iatrogenic or secondary to malignancy, often present a difficult management problem. Recent reports have suggested a role for covered metallic stents in this context. We describe the successful use of a covered stent to seal a persistent biliary leak following radiofrequency ablation of colorectal liver metastases

  1. Long-wave plasma radiofrequency ablation for treatment of xanthelasma palpebrarum.

    Science.gov (United States)

    Baroni, Adone

    2018-03-01

    Xanthelasma palpebrarum is the most common type of xanthoma affecting the eyelids. It is characterized by asymptomatic soft yellowish macules, papules, or plaques over the upper and lower eyelids. Many treatments are available for management of xanthelasma palpebrarum, the most commonly used include surgical excision, ablative CO 2 or erbium lasers, nonablative Q-switched Nd:YAG laser, trichloroacetic acid peeling, and radiofrequency ablation. This study aims to evaluate the effectiveness of RF ablation in the treatment of xanthelasma palpebrarum, with D.A.S. Medical portable device (Technolux, Italia), a radiofrequency tool working with long-wave plasma energy and without anesthesia. Twenty patients, 15 female and 5 male, affected by xanthelasma palpebrarum, were enrolled for long-wave plasma radiofrequency ablation treatment. The treatment consisted of 3/4 sessions that were carried out at intervals of 30 days. Treatments were well tolerated by all patients with no adverse effects and optimal aesthetic results. The procedure is very fast and can be performed without anesthesia because of the low and tolerable pain stimulation. Long-wave plasma radiofrequency ablation is an effective option for treatment of xanthelasma palpebrarum and adds an additional tool to the increasing list of medical devices for aesthetic treatments. © 2018 Wiley Periodicals, Inc.

  2. Benign thyroid nodule unresponsive to radiofrequency ablation treated with laser ablation: a case report.

    Science.gov (United States)

    Oddo, Silvia; Balestra, Margherita; Vera, Lara; Giusti, Massimo

    2018-05-11

    Radiofrequency ablation and laser ablation are safe and effective techniques for reducing thyroid nodule volume, neck symptoms, and cosmetic complaints. Therapeutic success is defined as a nodule reduction > 50% between 6 and 12 months after the procedure, but a percentage of nodules inexplicably do not respond to thermal ablation. We describe the case of a young Caucasian woman with a solid benign thyroid nodule who refused surgery and who had undergone radiofrequency ablation in 2013. The nodule did not respond in terms of either volume reduction or improvement in neck symptoms. After 2 years, given the patient's continued refusal of thyroidectomy, we proposed laser ablation. The nodule displayed a significant volume reduction (- 50% from radiofrequency ablation baseline volume, - 57% from laser ablation baseline), and the patient reported a significant improvement in neck symptoms (from 6/10 to 1/10 on a visual analogue scale). We conjecture that some benign thyroid nodules may be intrinsically resistant to necrosis when one specific ablation technique is used, but may respond to another technique. To the best of our knowledge, this is the first description of the effect of performing a different percutaneous ablation technique in a nodule that does not respond to radiofrequency ablation.

  3. Radiofrequency assisted pancreaticoduodenectomy for palliative surgical resection of locally advanced pancreatic adenocarcinoma.

    Science.gov (United States)

    Kumar, Jayant; Reccia, Isabella; Sodergren, Mikael H; Kusano, Tomokazu; Zanellato, Artur; Pai, Madhava; Spalding, Duncan; Zacharoulis, Dimitris; Habib, Nagy

    2018-03-20

    Despite careful patient selection and preoperative investigations curative resection rate (R0) in pancreaticoduodenectomy ranges from 15% to 87%. Here we describe a new palliative approach for pancreaticoduodenectomy using a radiofrequency energy device to ablate tumor in situ in patients undergoing R1/R2 resections for locally advanced pancreatic ductal adenocarcinoma where vascular reconstruction was not feasible. There was neither postoperative mortality nor significant morbidity. Each time the ablation lasted less than 15 minutes. Following radiofrequency ablation it was observed that the tumor remnant attached to the vessel had shrunk significantly. In four patients this allowed easier separation and dissection of the ablated tumor from the adherent vessel leading to R1 resection. In the other two patients, the ablated tumor did not separate from vessel due to true tumor invasion and patients had an R2 resection. The ablated remnant part of the tumor was left in situ. Whenever pancreaticoduodenectomy with R0 resection cannot be achieved, this new palliative procedure could be considered in order to facilitate resection and enable maximum destruction in remnant tumors. Six patients with suspected tumor infiltration and where vascular reconstruction was not warranted underwent radiofrequency-assisted pancreaticoduodenectomy for locally advanced pancreatic ductal adenocarcinoma. Radiofrequency was applied across the tumor vertically 5-10 mm from the edge of the mesenteric and portal veins. Following ablation, the duodenum and the head of pancreas were removed after knife excision along the ablated line. The remaining ablated tissue was left in situ attached to the vessel.

  4. Electromagnetic Fields, Pulsed Radiofrequency Radiation, and Epigenetics: How Wireless Technologies May Affect Childhood Development

    Science.gov (United States)

    Sage, Cindy; Burgio, Ernesto

    2018-01-01

    Mobile phones and other wireless devices that produce electromagnetic fields (EMF) and pulsed radiofrequency radiation (RFR) are widely documented to cause potentially harmful health impacts that can be detrimental to young people. New epigenetic studies are profiled in this review to account for some neurodevelopmental and neurobehavioral changes…

  5. The Bohm Criterion for Radiofrequency Discharges - a Numerical Verification Based on Poisson Equation

    NARCIS (Netherlands)

    Meijer, P. M.; W. J. Goedheer,

    1993-01-01

    Recently it was shown that, by using the analysis of electrostatic waves entering the plasma-sheath edge, the direct-current (dc) Bohm criterion also holds for discharges under radio-frequency (rf) conditions. In this paper, the influence of Bohm's criterion on the sheath characteristics for

  6. Radiofrequency-assisted Liposuction for Arm Contouring: Technique under Local Anesthesia

    Directory of Open Access Journals (Sweden)

    Spero Theodorou, MD

    2013-08-01

    Conclusions: In appropriately selected patients, RFAL arm contouring under local anesthesia represents an alternative procedure with acceptably low morbidity and high patient satisfaction. To achieve consistent results while minimizing complications, consideration to anatomic details, infiltration of the local anesthetic, and application of the radiofrequency energy must be given.

  7. Duodenorenal Fistula as a Complication of Radiofrequency Ablation of Hepatic Metastasis of Renal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Arman Erkan

    2017-06-01

    Full Text Available Duodenorenal fistula is a rare condition. The right kidney and the second part of the duodenum are in close anatomic proximity. Although unusual, fistulae can occur between these two anatomic structures. We report a patient who presented with duodenorenal fistula after radiofrequency ablation for renal cell carcinoma and its hepatic metastasis.

  8. Radio-frequency properties of stacked long Josephson junctions with nonuniform bias current distribution

    DEFF Research Database (Denmark)

    Filatrella, G; Pedersen, Niels Falsig

    1999-01-01

    We have numerically investigated the behavior of stacks of long Josephson junctions considering a nonuniform bias profile. In the presence of a microwave field the nonuniform bias, which favors the formation of fluxons, can give rise to a change of the sequence of radio-frequency induced steps...

  9. Effect of percutaneous renal sympathetic nerve radiofrequency ablation in patients with severe heart failure.

    Science.gov (United States)

    Dai, Qiming; Lu, Jing; Wang, Benwen; Ma, Genshan

    2015-01-01

    This study aimed to investigate the clinical feasibility and effects of percutaneous renal sympathetic nerve radiofrequency ablation in patients with heart failure. A total of 20 patients with heart failure were enrolled, aged from 47 to 75 years (63±10 years). They were divided into the standard therapy (n = 10), and renal nerve radiofrequency ablation groups (n = 10). There were 15 males and 5 female patients, including 8 ischemic cardiomyopathy, 8 dilated cardiomyopathy, and 8 hypertensive cardiopathy. All of the patients met the criteria of New York Heart Association classes III-IV cardiac function. Patients with diabetes and renal failure were excluded. Percutaneous renal sympathetic nerve radiofrequency ablation was performed on the renal artery wall under X-ray guidance. Serum electrolytes, neurohormones, and 24 h urine volume were recorded 24 h before and after the operation. Echocardiograms were performed to obtain left ventricular ejection fraction at baseline and 6 months. Heart rate, blood pressure, symptoms of dyspnea and edema were also monitored. After renal nerve ablation, 24 h urine volume was increased, while neurohormone levels were decreased compared with those of pre-operation and standard therapy. No obvious change in heart rate or blood pressure was recorded. Symptoms of heart failure were improved in patients after the operation. No complications were recorded in the study. Percutaneous renal sympathetic nerve radiofrequency ablation may be a feasible, safe, and effective treatment for the patients with severe congestive heart failure.

  10. Pulmonary venous thrombosis secondary to radiofrequency ablation of the pulmonary veins

    Directory of Open Access Journals (Sweden)

    Raquel López-Reyes

    Full Text Available Background: Pulmonary Vein Thrombosis (PVT is a rare and underdiagnosed entity produced by local mechanical nature mechanisms, vascular torsion or direct injury to the vein. PVT has been described in clinical cases or small multicenter series mainly in relation to pulmonary vein stenosis, metastatic carcinoma, fibrosing mediastinitis, as an early surgical complication of lung transplantation lobectomy and radiofrequency ablation performed in patients with atrial fibrillation, although in some cases the cause is not known. Case: We report the case of a 57 years old male with history of atrial fibrillation treated by radiofrequency ablation who was admitted in our center because of a two-week history of consistent pleuritic pain in the left hemithorax and low-grade hemoptysis and a lung consolidation treated as a pneumonia with antibiotic but not responding to medical therapy. In view of the poor evolution of the patient, computed tomography angiography was performed with findings of PVT and secondary venous infarction and anticoagulation therapy was optimized. At the end, pulmonary resection was performed due to hemorrhagic recurrence. Conclusion: PVT remains a rare complication of radiofrequency ablation and other procedures involving pulmonary veins. Clinical suspicion and early diagnosis is crucial because is a potentially life-threatening entity. Keywords: Venous thrombosis, Atrial fibrilation, Radiofrequency ablation, Hemoptysis, Lung consolidation, Lung infarction, Lung resection surgery

  11. Adverse effects of radiofrequency ablation of liver tumours in the Netherlands

    NARCIS (Netherlands)

    Jansen, M. C.; van Duijnhoven, F. H.; van Hillegersberg, R.; Rijken, A.; van Coevorden, F.; van der Sijp, J.; Prevoo, W.; van Gulik, T. M.

    2005-01-01

    Background: Radiofrequency ablation (RFA) is a new treatment for liver tumours. Complications encountered after RFA in the Netherlands were evaluated in the present study. Methods: Between June 1999 and November 2003 patients undergoing RFA of irresectable liver tumours in eight medical centres were

  12. Graphene screen-printed radio-frequency identification devices on flexible substrates

    NARCIS (Netherlands)

    Arapov, K.; Jaakkola, K.; Ermolov, V.; Bex, G.; Rubingh, E.; Haque, S.; Sandberg, H.; Abbel, R.; de With, G.; Friedrich, H.

    2016-01-01

    Despite the great promise of printed flexible electronics from 2D crystals, and especially graphene, few scalable applications have been reported so far that can be termed roll-to-roll compatible. Here we combine screen printed graphene with photonic annealing to realize radio-frequency

  13. Use of a radio-frequency resonance circuit in studies of alkali ionization in flames

    International Nuclear Information System (INIS)

    Borgers, A.J.

    1978-01-01

    The construction of a radio-frequency resonance system and its use in the study of alkali metal ionization in flames is described. The author re-determines the values of the alkali ionization rate constants for a CO flame with N 2 as diluent gas of known temperature using the RF resonance method. (Auth.)

  14. Scheme to funnel ion beams with a radio-frequency quadrupole

    International Nuclear Information System (INIS)

    Stokes, R.H.; Minerbo, G.N.

    1985-01-01

    We describe a proposed method to funnel ion beams using a new form of the radio-frequency quadrupole (RFQ) structure. This RFQ accepts two bunched ion beams and combines them into a single final beam with interlaced microstructure pulses. It also provides uninterrupted periodic transverse focusing to facilitate the funneling of beams with high current and low emittance

  15. Breakdown criteria due to radio-frequency fields in vacuum. Final report

    International Nuclear Information System (INIS)

    Reid, D.W.; Lohsen, R.A.

    1982-01-01

    The factors that affect the voltage at which vacuum gaps break down are analyzed. Based on the literature and some simplifying assumptions, a functional dependence is hypothesized. The hypothesis is related to a proposed experiment using radio-frequency power to generate the breakdown voltage

  16. A superconducting radio-frequency cavity for manipulating the phase space of pion beams at LAMPF

    Energy Technology Data Exchange (ETDEWEB)

    O' Donnell, J.M.; Davis, J.; DeHaven, R.A.; Gray, E.; Johnson, R.; Lomax, R.E.; McCloud, B.J.; McGill, J.A.; Morris, C.L.; Novak, J.; Rusnak, B.; Tubb, G. (Los Alamos National Lab., Los Alamos, NM (United States)); Applegate, J.M.; Averett, T.D.; Beck, J.; Ritchie, B.G. (Arizona State Univ., Tempe, AZ (United States)); Haebel, E. (CERN, Geneva (Switzerland)); Kiehlmann, D.; Klein, U.; Peniger, M.; Schaefer, P.; Vogel, H. (Siemens AG, Accelerator and Magnet Technology, Bergisch Gladbach (Germany)); Ward, H.; Moore, C.F. (Univ. of Texas, Austin, TX (United States))

    1992-07-15

    The SCRUNCHER is a superconducting radio-frequency cavity for manipulating the longitudinal phase space of the secondary pion beam from the low energy pion channel at LAMPF. Test results of the cavity performance and initial results from in-beam tests are presented. (orig.).

  17. A superconducting radio-frequency cavity for manipulating the phase space of pion beams at LAMPF

    Science.gov (United States)

    O'Donnell, J. M.; Davis, J.; DeHaven, R. A.; Gray, E.; Johnson, R.; Lomax, R. E.; McCloud, B. J.; McGill, J. A.; Morris, C. L.; Novak, J.; Rusnak, B.; Tubb, G.; Applegate, J. M.; Averett, T. D.; Beck, J.; Ritchie, B. G.; Haebel, E.; Kiehlmann, D.; Klein, U.; Peiniger, M.; Schäfer, P.; Vogel, H.; Ward, H.; Fred Moore, C.

    1992-07-01

    The SCRUNCHER is a superconducting radio-frequency cavity for manipulating the longitudinal phase space of the secondary pion beam from the low energy pion channel at LAMPF. Test results of the cavity performance and initial results from in-beam tests are presented.

  18. Evaluation of microneedling fractional radiofrequency device for treatment of acne scars

    Directory of Open Access Journals (Sweden)

    Byalekere Shivanna Chandrashekar

    2014-01-01

    Full Text Available Background: Various treatment modalities including non-invasive methods such as chemical peels, topical retinoids, microdermabrasion, minimally invasive techniques such as microneedling, fractional lasers, microneedling radiofrequency devices and invasive procedures such as acne scar surgeries and ablative lasers are used for acne scars, each with its own unique advantages and disadvantages. This study is a retrospective assessment of efficacy and safety of microneedling fractional radiofrequency in the treatment of acne scars. Methods: Thirty one patients of skin types III-V with moderate and severe facial acne scarring received four sequential fractional radiofrequency treatments over a period of 6 months with an interval of 6 weeks between each session. Goodman & Baron′s acne scar grading system was used for assessment by a side by side comparison of preoperative and post- operative photographs taken at their first visit and at the end of 3 months after the last session. Results: Estimation of improvement with Goodman and Baron′s Global Acne Scarring System showed that by qualitative assessment of 31 patients with grade 3 and grade 4 acne scars, 80.64% showed improvement by 2 grades and 19.35% showed improvement by 1 grade. Quantitative assessment showed that 58% of the patients had moderate, 29% had minimal, 9% had good and 3% showed very good improvement. Adverse effects were limited to transient pain, erythema, edema and hyperpigmentation. Conclusion: Microneedling fractional radiofrequency is efficacious for the treatment of moderate and severe acne scars.

  19. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)], E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain); Nieto-Morales, M Luisa [Servicio de Radiologia, Hospital Universitario de Tenerife (Spain); Ortiz, Eduardo J. [Departamento de Cirugia Ortopedica, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)

    2009-09-15

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  20. Measuring changes of radio-frequency dielectric properties of chicken meat during storage

    Science.gov (United States)

    Changes in dielectric properties of stored chicken meat were tracked by using a radio-frequency dielectric spectroscopy method. For this purpose, the dielectric properties were measured with an open-ended coaxial-line probe and vector network analyzer over a broad frequency range from 200 MHz to 20...

  1. Stress (Tako-Tsubo) Cardiomyopathy Following Radiofrequency Ablation of a Liver Tumor: A Case Report

    International Nuclear Information System (INIS)

    Joo, Ijin; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn; Park, Eun-Ah

    2011-01-01

    Stress cardiomyopathy is characterized by transient left ventricular dysfunction occurring in the absence of obstructive coronary disease. It is precipitated by acute emotional or physical stress. We present a case of stress cardiomyopathy which developed during hepatic radiofrequency ablation of hepatocellular carcinoma.

  2. Computed tomography findings after radiofrequency ablation in locally advanced pancreatic cancer

    NARCIS (Netherlands)

    Rombouts, Steffi J. E.; Derksen, Tyche C.; Nio, Chung Y.; van Hillegersberg, Richard; van Santvoort, Hjalmar C.; Walma, Marieke S.; Molenaar, Izaak Q.; van Leeuwen, Maarten S.

    2018-01-01

    The purpose of the study was to provide a systematic evaluation of the computed tomography(CT) findings after radiofrequency ablation (RFA) in locally advanced pancreatic cancer(LAPC). Eighteen patients with intra-operative RFA-treated LAPC were included in a prospective case series. All CT-scans

  3. Pulsed Radiofrequency in the Treatment of Persistent Pain After Inguinal Herniotomy

    DEFF Research Database (Denmark)

    Werner, Mads U; Bischoff, Joakim Mutahi; Rathmell, James P

    2012-01-01

    . The use of pulsed radiofrequency (PFR), leading to nondestructive lesions of nerve structures, has been proposed as a treatment option. To examine the evidence of treatment efficacy, a systematic literature search was made. From the databases PubMed, Embase, and CINAHL, 4 case reports were retrieved and 8...

  4. Loop radiofrequency coils for clinical magnetic resonance imaging at 7 tesla

    NARCIS (Netherlands)

    Kraff, O.

    2011-01-01

    To date, the 7 T magnetic resonance imaging (MRI) scanner remains a pure research system and there is still a long way ahead till full clinical integration. Key challenges are the absence of a body transmit radiofrequency (RF) coil as well as of dedicated RF coils in general, short RF wavelengths of

  5. Effects of 1.84 GHz radio-frequency electromagnetic field on sperm ...

    African Journals Online (AJOL)

    sunny t

    Key words: 1.84 GHz, radio-frequency electromagnetic field (RF-EMF), epididymis, ... Author(s) agree that this article remains permanently open access under the terms of the ..... mouse testis after the long-term administration of nickel in feed.

  6. Radiofrequency denervation of the hip joint for pain management: case report and literature review.

    Science.gov (United States)

    Gupta, Gaurav; Radhakrishna, Mohan; Etheridge, Paul; Besemann, Markus; Finlayson, Robert J

    2014-01-01

    A 55-year-old male presented with severe pain and functional limitations as a result of left hip osteoarthritis. He had failed multiple treatments while waiting for a hip arthroplasty, including physical therapy, medications, and various intra-articular injections. Thermal radiofrequency lesioning of the obturator and femoral articular branches to the hip joint was offered in the interim. To our knowledge, this is the first report to describe an inferior-lateral approach for lesioning the obturator branch, the clinical application of successive lesions to increase denervation area, and outcomes in a patient receiving a second treatment with previously good results. To discuss relevant and technical factors for this specific case, we reviewed previous literature on hip joint radiofrequency and critically evaluated previous anatomic studies in the context of radiofrequency. The first treatment provided significant benefit for a period of 6 months. A second treatment was employed providing only mild to moderate benefit until his joint replacement surgery 4 months later. Literature review revealed studies of low quality secondary to small sample sizes, patient selection methodology, inclusion of patients with heterogenous etiologies for pain, variable needle placement techniques, and lack of measurement of functional outcomes. Case report and low quality studies in existing literature. Hip joint radiofrequency denervation is a promising avenue for adjunctive treatment of hip pain. Further cadaveric studies are required to clarify a multitude of technical parameters. Once these are well defined, future clinical studies should consider pain, functional, and economic outcomes in their design.

  7. Electromagnetic and Thermal Aspects of Radiofrequency Field Propagation in Ultra-High Field MRI

    NARCIS (Netherlands)

    van Lier, A.L.H.M.W.

    2012-01-01

    In MRI, a radiofrequency (RF) pulse is used to generate a signal from the spins that are polarized by a strong magnetic field. For higher magnetic field strengths, a higher frequency of the RF pulse is required in order to match the Larmor frequency. A higher frequency, in turn, leads to a shorter

  8. Cervical radiofrequency neurotomy reduces central hyperexcitability and improves neck movement in individuals with chronic whiplash.

    Science.gov (United States)

    Smith, Ashley Dean; Jull, Gwendolen; Schneider, Geoff; Frizzell, Bevan; Hooper, Robert Allen; Sterling, Michele

    2014-01-01

    This study aims to determine if cervical medial branch radiofrequency neurotomy reduces psychophysical indicators of augmented central pain processing and improves motor function in individuals with chronic whiplash symptoms. Prospective observational study of consecutive patients with healthy control comparison. Tertiary spinal intervention centre in Calgary, Alberta, Canada. Fifty-three individuals with chronic whiplash associated disorder symptoms (Grade 2); 30 healthy controls. Measures were made at four time points: two prior to radiofrequency neurotomy, and 1- and 3-months post-radiofrequency neurotomy. Measures included: comprehensive quantitative sensory testing (including brachial plexus provocation test), nociceptive flexion reflex, and motor function (cervical range of movement, superficial neck flexor activity during the craniocervical flexion test). Self-report pain and disability measures were also collected. One-way repeated measures analysis of variance and Friedman's tests were performed to investigate the effect of time on the earlier measures. Differences between the whiplash and healthy control groups were investigated with two-tailed independent samples t-test or Mann-Whitney tests. Following cervical radiofrequency neurotomy, there were significant early (within 1 month) and sustained (3 months) improvements in pain, disability, local and widespread hyperalgesia to pressure and thermal stimuli, nociceptive flexor reflex threshold, and brachial plexus provocation test responses as well as increased neck range of motion (all P  0.13) was measured. Attenuation of psychophysical measures of augmented central pain processing and improved cervical movement imply that these processes are maintained by peripheral nociceptive input. Wiley Periodicals, Inc.

  9. Capacitively coupled radio-frequency discharges in nitrogen at low pressures

    KAUST Repository

    Alves, Luí s Lemos; Marques, Luí s S A; Pintassilgo, Carlos D.; Wattieaux, Gaë tan; Es-sebbar, Et-touhami; Berndt, Johannes; Kovačević, Eva; Carrasco, Nathalie; Boufendi, Laï fa; Cernogora, Guy

    2012-01-01

    This paper uses experiments and modelling to study capacitively coupled radio-frequency (rf) discharges in pure nitrogen, at 13.56MHz frequency, 0.11 mbar pressures and 230W coupled powers. Experiments performed on two similar (not twin) setups

  10. Radiofrequency Coblation Versus Intramural Bipolar Cautery for the Treatment of Inferior Turbinate Hypertrophy.

    Science.gov (United States)

    Shah, Anil N; Brewster, Douglas; Mitzen, Kelly; Mullin, David

    2015-09-01

    Compare intramural bipolar electrocautery and radiofrequency coblation in the treatment of inferior turbinate hypertrophy with regards to objective and subjective improvement in nasal obstruction, rate and type of complications, experience during the procedure, and rate of recovery. Prospective, single-blinded study. Single tertiary medical center from 2008 to 2010. Forty-one adult patients with inferior turbinate hypertrophy refractory to medical management were treated with radiofrequency coblation in one nostril and intramural bipolar cautery in the other. Subjective and objective data, including use of a Visual Analog Scale (VAS) for subjective outcomes, acoustic rhinometry, and nasal endoscopy, were then obtained from each patient comparing the 2 techniques. Radiofrequency coblation was significantly less painful than intramural bipolar cautery during the procedure (P = .03) and during the early postoperative period (P measured by acoustic rhinometry and subjective VAS outcomes. Radiofrequency coblation seems to offer an equivalent alternative to bipolar electrocautery for the treatment of inferior turbinate hypertrophy with less discomfort during the procedure and early post-operative period. © The Author(s) 2015.

  11. Comparison of Voice Quality Between Patients Who Underwent Inferior Turbinoplasty or Radiofrequency Cauterization.

    Science.gov (United States)

    Göker, Ayşe Enise; Aydoğdu, İmran; Saltürk, Ziya; Berkiten, Güler; Atar, Yavuz; Kumral, Tolgar Lütfi; Uyar, Yavuz

    2017-01-01

    The aim of this study was to analyze and compare the vocal quality in patients who underwent either submucosal turbinectomy or radiofrequency cauterization. In this study, we enrolled 60 patients diagnosed with inferior concha hypertrophy. These patients were divided into two groups by using computer program "Research Randomizer." Of the 60 patients, 30 underwent submucosal inferior turbinoplasty and 30 underwent radiofrequency cauterization. The control group was composed of 30 healthy adults with no nasal or upper aerodigestive system pathology. The patients were checked at weeks 1, 2, and 4. Voice records were taken before the procedure and at week 4 postprocedure. The mean age of patients in the inferior turbinoplasty group was 29.4 years (range: 19-42 years); in the radiofrequency group, it was 30.30 years (range: 18-50 years). There was no statistical difference in age between groups. In the inferior turbinoplasty group, there were 16 male and 14 female patients, and in the radiofrequency group, there were 13 male and 17 female patients. There was no significant difference in the number of males and females between groups. Voice professionals, especially singers, actors, and actresses, should be informed about possible voice changes before undergoing endonasal surgery because these individuals are more sensitive to changes in resonance organs. We believe that voice quality should be regarded as a highly important parameter when measuring the success of endonasal surgery. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  12. Neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia.

    Science.gov (United States)

    Zhang, W C; Zhong, W X; Li, S T; Zheng, X S; Yang, M; Shi, J

    2012-03-01

    Although radiofrequency thermocoagulation is considered as a primary treatment for most patients with trigeminal neuralgia, neuronavigator-guided percutaneous radiofrequency thermocoagulation has been rarely reported. The object of this study was to assess the clinical value of neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia. The radiofrequency thermocoagulation was performed in 100 cases of trigeminal neuralgia. The patients were positioned supine or sitting, under Hartel's technique (reported by Sweet and Wepsic J Neurosurg 40:143-156, 1974), by anterior lateral facial approaches. The Gasserian ganglions were acupunctured, assisted by intraoperative CT scanning (3-digital reconstruction) and electrophysiology in order to accurately locate target. The needles located in oval foramen at the first puncture, the direction and position could be defined according to the electrophysiology examination. The pain alleviated immediately after operation. There occurred no serious complication and other nerve injury in all patients despite face numbness only. 3D-CT and electrophysiology Gasser's ganglion locations can raise the success rate of puncture, enhance the safety and reduce the incidence of complication, showing high academic value and its promising future.

  13. Radiofrequency Ablation versus Cryoablation in the Treatment of Paroxysmal Atrial Fibrillation: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Ali H. Hachem

    2018-01-01

    Full Text Available Background. Pulmonary vein isolation is commonly performed using radiofrequency energy with cryoablation gaining acceptance. We performed a meta-analysis of randomized controlled trials which compared radiofrequency versus cryoablation for patients with atrial fibrillation. Methods. A systematic search strategy identified both published and unpublished articles from inception to November 10, 2016, in multiple databases. The primary outcomes for this meta-analysis were long-term freedom from atrial fibrillation at 12-month follow-up and overall postoperative complication rates. For all included studies, the methodological quality was assessed through the Cochrane Collaboration’s tool for risk of bias. Results. A total of 247 articles were identified with eight being included in this review as they satisfied the prespecified inclusion criteria. Overall, there was no significant difference in freedom from atrial fibrillation at ≥12-month follow-up between those receiving cryoballoon and radiofrequency ablation, respectively (OR = 0.98, CI = 0.67–1.43, I2 = 56%, p=0.90. Additionally, the secondary outcomes of duration of ablation, fluoroscopy time, and ablation time failed to reach significance. Cryoballoon ablation had significantly greater odds of postoperative phrenic nerve injury at 12-month follow-up. Conclusions. Our meta-analysis suggests that cryoballoon ablation provides comparable benefits with regard to freedom from atrial fibrillation at medium-term follow-up, fluoroscopy time, ablation time, operative duration, and overall complication rate in comparison to radiofrequency ablation.

  14. Vacuum pumping system for the JT-60 radio-frequency heating system

    International Nuclear Information System (INIS)

    Yokokura, Kenji; Ikeda, Yoshitaka; Imai, Tuyoshi; Suganuma, Kazuaki; Nagashima, Takashi

    1988-01-01

    The basic design requirements set up for the JT-60 radio-frequency heating system included: (1) rapid pumping of gas released upon application of a radio-frequency power to maintain the pressure in the launchers at 10 -2 - 10 -3 Pa or less, (2) incorporation of a gas analysis system that can operate under a strong field and high pressure (>10 -2 Pa) to permit remote controlled data collection and processing, and (3) low cost, multiple functions and high reliability. The vacuum pumping system, consisting of three units for low hybrid radio-frequency (LHRF) and one unit for ion cyclotron radio-frequency (ICRF), is connected to each launcher provided at the four ports of JT-60. The LHRF unit is composed of a main pump, an alumina joint for electrical insulation from the launcher, a metallic gate valve for isolation from the JT-60 vacuum region, and various vacuum gauges. Only a turbo-molecular pump is used for the ICRF system because a large-scale differential pumping is not required. A gas measuring system is incorporated which consists of a mass filter, personal computer, turbo-molecular pump, and variable flow valve equipped with an APG control. This system is designed to identify and make use of gas impurities released during the launcher aging process. The control system employed consists of a personal computer, interlock control board, data logger and other devices such as vacuum gages. (Nogami, K.)

  15. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    International Nuclear Information System (INIS)

    Martel, Jose; Bueno, Angel; Nieto-Morales, M Luisa; Ortiz, Eduardo J.

    2009-01-01

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  16. Manual B-mode versus automated radio-frequency carotid intima-media thickness measurements

    NARCIS (Netherlands)

    Dogan, Soner; Plantinga, Yvonne; Dijk, Joke M.; van der Graaf, Yolanda; Grobbee, Diederick E.; Bots, Michiel L.; Algra, N. N.; Doevendans, P. A.; Eikelboom, C.; van der Graaf, Y.; Grobbee, E.; Kappelle, L. J.; Mali, W. P. Th M.; Moll, F. L.; Rutten, G. E. H. M.; Visseren, F. L. J.

    2009-01-01

    Carotid intima-media thickness (CIMT) serves as an indicator of atherosclerosis and cardiovascular risk. Manual measurements of B-mode ultrasound images are the most applied method. Automated measurements with radiofrequency (RF) ultrasound have been suggested as an alternative. The aim of this

  17. Ophthalmic branch radiofrequency thermocoagulation for atypical trigeminal neuralgia:a case report.

    Science.gov (United States)

    Du, Shibin; Ma, Xiaoliang; Li, Xiaoqin; Yuan, Hongjie

    2015-01-01

    Trigeminal neuralgia is an intense neuralgia involving facial areas supplied by trigeminal nerve. The pain is characterized by sudden onset, short persistence, sharp or lancinating. Trigeminal neuralgia commonly affects frontal areas, infraorbital or paranasal areas, mandibular areas and teeth. While Trigeminal neuralgia affecting merely the upper eyelid is rare. Here we report a case of atypical Trigeminal neuralgia confined to the upper eyelid. The patient was pain free during the follow-up period of 6 months after unusual ophthalmic branch radiofrequency thermocoagulation. A 55-year-old female patient was diagnosed as primary trigeminal neuralgia involving the right upper eyelid. As the pain could not be controlled by drug therapy, peripheral nerve branch radiofrequency thermocoagulation was recommended. A combination of infratrochlear, supratrochlear and lacrimal radiofrequency thermocoagulation was implemented in this case. The point where the bridge of the nose abuts the supraorbital ridge and the point slightly above the lateral canthus along outer border of the orbit were selected respectively as the puncture sites. After positive diagnostic test, radiofrequency thermocoagulation of the above-mentioned nerve branches was performed respectively. The patient was pain free immediately after the treatment and during the follow-up period of 6 months. Trigeminal neuralgia is a common severe and chronic facial neuralgia which requires accurate diagnosis and effective therapy. With typical clinical symptoms, normal neurological signs, normal CT and MRI findings, the patient was diagnosed as classic trigeminal neuralgia. As the patient was drug resistant, some invasive treatments were considered. Peripheral branch neurolysis was chosen for its minimal invasiveness, convenience, low risk and not affecting further invasive treatments. According to the anatomic data and the diagnostic test results, infratrochlear, supratrochlear and lacrimal nerve were responsible

  18. Sphenopalatine ganglion: block, radiofrequency ablation and neurostimulation - a systematic review.

    Science.gov (United States)

    Ho, Kwo Wei David; Przkora, Rene; Kumar, Sanjeev

    2017-12-28

    Sphenopalatine ganglion is the largest collection of neurons in the calvarium outside of the brain. Over the past century, it has been a target for interventional treatment of head and facial pain due to its ease of access. Block, radiofrequency ablation, and neurostimulation have all been applied to treat a myriad of painful syndromes. Despite the routine use of these interventions, the literature supporting their use has not been systematically summarized. This systematic review aims to collect and summarize the level of evidence supporting the use of sphenopalatine ganglion block, radiofrequency ablation and neurostimulation. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on sphenopalatine ganglion block, radiofrequency ablation and neurostimulation. Studies included in this review were compiled and analyzed for their treated medical conditions, study design, outcomes and procedural details. Studies were graded using Oxford Center for Evidence-Based Medicine for level of evidence. Based on the level of evidence, grades of recommendations are provided for each intervention and its associated medical conditions. Eighty-three publications were included in this review, of which 60 were studies on sphenopalatine ganglion block, 15 were on radiofrequency ablation, and 8 were on neurostimulation. Of all the studies, 23 have evidence level above case series. Of the 23 studies, 19 were on sphenopalatine ganglion block, 1 study on radiofrequency ablation, and 3 studies on neurostimulation. The rest of the available literature was case reports and case series. The strongest evidence lies in using sphenopalatine ganglion block, radiofrequency ablation and neurostimulation for cluster headache. Sphenopalatine ganglion block also has evidence in treating trigeminal neuralgia, migraines, reducing the needs of analgesics after endoscopic sinus surgery and reducing pain associated with nasal packing

  19. Longitudinal outcomes of radiofrequency ablation versus surveillance endoscopy for Barrett's esophagus with low-grade dysplasia.

    Science.gov (United States)

    Kahn, A; Al-Qaisi, M; Kommineni, V T; Callaway, J K; Boroff, E S; Burdick, G E; Lam-Himlin, D M; Temkit, M; Vela, M F; Ramirez, F C

    2018-04-01

    Radiofrequency ablation of Barrett's esophagus with low-grade dysplasia is recommended in recent American College of Gastroenterology guidelines, with endoscopic surveillance considered a reasonable alternative. Few studies have directly compared outcomes of radiofrequency ablation to surveillance and those that have are limited by short duration of follow-up. This study aims to compare the long-term effectiveness of radiofrequency ablation versus endoscopic surveillance in a large, longitudinal cohort of patients with Barrett's esophagus, and low-grade dysplasia.We conducted a retrospective analysis of patients with confirmed low-grade dysplasia at a single academic medical center from 1991 to 2014. Patients progressing to high-grade dysplasia or esophageal adenocarcinoma within one year of index LGD endoscopy were defined as missed dysplasia and excluded. Risk factors for progression were assessed via Cox proportional hazards model. Comparison of progression risk was conducted using a Kaplan-Meier analysis. Subset analyses were conducted to examine the effect of reintroducing early progressors and excluding patients diagnosed prior to the advent of ablative therapy. Of 173 total patients, 79 (45.7%) underwent radiofrequency ablation while 94 (54.3%) were untreated, with median follow up of 90 months. Seven (8.9%) patients progressed to high-grade dysplasia or adenocarcinoma despite ablation, compared with 14 (14.9%) undergoing surveillance (P = 0.44). This effect was preserved when patients diagnosed prior to the introduction of radiofrequency ablation were excluded (8.9% vs 13%, P = 0.68). Reintroduction of patients progressing within the first year of follow-up resulted in a trend toward significance for ablation versus surveillance (11.1% vs 23.8%, P = 0.053).In conclusion, progression to high-grade dysplasia or adenocarcinoma was not significantly reduced in the radiofrequency ablation cohort when compared to surveillance. Despite recent studies

  20. Radiofrequency ablation of atrial tachyarrhythmias in adults with tetralogy of Fallot - predictors of success and outcome.

    Science.gov (United States)

    Ezzat, Vivienne A; Ryan, Matthew J; O'Leary, Justin; Ariti, Cono; Deanfield, John; Pandya, Bejal; Cullen, Shay; Walker, Fiona; Khan, Fakhar; Abrams, Dominic J; Lambiase, Pier D; Lowe, Martin D

    2017-03-01

    Adults with tetralogy of Fallot experience atrial tachyarrhythmias; however, there are a few data on the outcomes of radiofrequency ablation. We examined the characteristics, outcome, and predictors of recurrence of atrial tachyarrhythmias after radiofrequency ablation in tetralogy of Fallot patients. Methods/results Retrospective data were collected from 2004 to 2013. In total, 56 ablations were performed on 37 patients. We identified two matched controls per case: patients with tetralogy of Fallot but no radiofrequency ablation and not known to have atrial tachyarrhythmias. Acute success was 98%. Left atrial arrhythmias increased in frequency over time. The mean follow-up was 41 months; 78% were arrhythmia-free. Number of cardiac surgeries, age, and presence of atrial fibrillation were predictors of recurrence. Lone cavo-tricuspid isthmus-dependent flutter reduced the likelihood of atrial fibrillation. Right and left atria in patients with tetralogy of Fallot were larger in ablated cases than controls. NYHA class was worse in cases and improved after ablation; baseline status predicted death. Of matched non-ablated controls, a number of them had atrial fibrillation. These patients were excluded from the case-control study but analysed separately. Most of them had died during follow-up, whereas of the matched ablated cases all were alive and the majority in sinus rhythm. Patients with tetralogy of Fallot and atrial tachyarrhythmias have more dilated atria than those without atrial tachyarrhythmias. Radiofrequency ablation improves functional status. Left atrial ablation is more commonly required with repeat procedures. There is a high prevalence of atrial tachyarrhythmias, particularly atrial fibrillation, in patients with tetralogy of Fallot; early radiofrequency ablation may have a protective effect against this.

  1. Radiofrequency Ablation in Coccydynia: A Case Series and Comprehensive, Evidence-Based Review.

    Science.gov (United States)

    Chen, Yian; Huang-Lionnet, Julie H Y; Cohen, Steven P

    2017-06-01

    Coccydynia is a condition with a multitude of different causes, characterized by ill-defined management. There are multiple prospective studies, including several controlled trials, that have evaluated conservative therapies. Additionally, a plethora of observational studies have assessed coccygectomy, but few studies have reported results for nonsurgical interventional procedures. In this report, we describe the treatment results of 12 patients who received conventional or pulsed radiofrequency for coccydynia and systematically review the literature on management. We performed a retrospective data analysis evaluating patients who underwent pulsed or conventional radiofrequency treatment at Johns Hopkins Hospital and Walter Reed National Military Medical Center. A comprehensive literature review was also performed to contextualize these results. The mean age of patients treated was 50.25 years (SD = 11.20 years, range = 32-72 years), with the mean duration of symptoms being 3.6 years (SD = 3.36 years, range 1-10 years). There were 10 males and two females in this cohort. Among patients who received radiofrequency treatment, the average benefit was 55.5% pain relief (SD = 30.33%, range = 0-100%). Those who underwent conventional (vs pulsed radiofrequency) and who received prognostic blocks were more likely to experience a positive outcome. There were two cases of neuritis, which resolved spontaneously after several weeks. Radiofrequency ablation of the sacrococcygeal nerves may serve as a useful treatment option for patients with coccydynia who have failed more conservative measures. Further research into this therapeutic approach and its benefit for coccydynia should incorporate a control group for comparison. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  2. Three Cycles of Radiofrequency Ablation Are More Efficacious Than Two in the Management of Morton's Neuroma.

    Science.gov (United States)

    Brooks, David; Parr, Adam; Bryceson, William

    2018-04-01

    Morton's neuroma is a common cause of forefoot pain. Outcomes of conservative therapy are mixed and many patients undergo operative intervention. Radiofrequency ablation has recently gained favor as a treatment option, although the optimal regime is unknown. This study investigates the effectiveness of 2 versus 3 cycles of radiofrequency ablation for the treatment of Morton's neuroma. We surveyed a cohort of patients with Morton's neuroma who had progressed to radiofrequency ablation after failed conservative treatment. Patients received either 2 or 3 cycles of radiofrequency ablation by a single surgeon. We assessed patients based on their change in numerical pain rating scale, symptom improvement, complications, and progression to surgical excision through a series of telephone interviews. Outcomes between the 2 treatment arms were compared by parametric tests. Twenty-eight patients were included in the study. Eighteen patients with 21 neuromas received 2 cycles and 10 patients with 11 neuromas received 3 cycles. Mean time of follow-up was 12.9 months. Overall, 88% of patients were either very or moderately satisfied with their outcome. In patients who received 2 cycles mean numerical pain scores decreased from 7.9 ± 1.1 to 3.4 ± 2.4 postprocedure. Three patients progressed to operative excision. In patients who received 3 cycles, numerical pain scores decreased from 8.0 ± 1.0 to 1.5 ± 2.0 postprocedure. One patient progressed to operative excision. Patients who received 3 cycles had reduced medium-term pain postoperatively compared with 2 cycles (3.4 ± 2.4 vs 1.5 ± 2.0, P = .011). Radiofrequency ablation provides a high rate of patient satisfaction in the treatment of Morton's neuroma with few side effects. It appears that 3 cycles may be superior to 2 cycles but a randomized controlled trial will be required to confirm these results. Intervention, Level III: Comparative study without concurrent controls.

  3. Efficacy of inferior turbinoplasty with the use of CO(2) laser, radiofrequency, and electrocautery.

    Science.gov (United States)

    Prokopakis, Emmanuel P; Koudounarakis, Eleftherios I; Velegrakis, George A

    2014-01-01

    Inferior turbinate surgery is one of the most commonly performed methods for the treatment of rhinitis symptoms, especially nasal obstruction. This is a comparative study of CO2 laser, electrocautery, and radiofrequency turbinoplasty in the treatment of rhinitis symptoms. From 1994 to 2011, 3219 patients were enrolled in the study. Two hundred eighty-three patients were lost during follow-.up. Of the remaining 2936 patients, 1066 were managed using the CO2 laser, whereas 664 and 1206 were managed with the use of radiofrequency and electrocautery, respectively. All procedures were performed under local anesthesia. Patients were asked to evaluate their symptoms with the visual analog scale (VAS) preoperatively, as well as 1 month and 1 year postoperatively. Rhinomanometry was used to objectively evaluate the effect on nasal obstruction. Mean VAS values preoperatively, regarding nasal obstruction, were 7.43 ± 0.96, 7.33 ± 0.87, and 7.64 ± 0.95 in the CO2 laser, radiofrequency, and electrocautery group, respectively. One month postoperatively, the score was significantly improved in all groups (CO2 laser, 3.44 ± 0.99; radiofrequency, 3.26 ± 0.76; electrocautery, 3.19 ± 0.79), which was almost stable in the 1st year of follow-up. Similar results were also observed in the evaluation of sneezing and rhinorrhea. Outcome did not statistically differ between the three methods. The CO2 laser, radiofrequency and electrocautery offer excellent postoperative results in turbinoplasty cases under local anesthesia.

  4. Temperature responsive porous silicon nanoparticles for cancer therapy - spatiotemporal triggering through infrared and radiofrequency electromagnetic heating.

    Science.gov (United States)

    Tamarov, Konstantin; Xu, Wujun; Osminkina, Liubov; Zinovyev, Sergey; Soininen, Pasi; Kudryavtsev, Andrey; Gongalsky, Maxim; Gaydarova, Azha; Närvänen, Ale; Timoshenko, Victor; Lehto, Vesa-Pekka

    2016-11-10

    One critical functionality of the carrier system utilized in targeted drug delivery is its ability to trigger the release of the therapeutic cargo once the carrier has reached its target. External triggering is an alluring approach as it can be applied in a precise spatiotemporal manner. In the present study, we achieved external triggering through the porous silicon (PSi) nanoparticles (NPs) by providing a pulse of infrared or radiofrequency radiation. The NPs were grafted with a temperature responsive polymer whose critical temperature was tailored to be slightly above 37°C. The polymer coating improved the biocompatibility of the NPs significantly in comparison with their uncoated counterparts. Radiation induced a rapid temperature rise, which resulted in the collapse of the polymer chains facilitating the cargo release. Both infrared and radiofrequency radiation were able to efficiently trigger the release of the encapsulated drug in vitro and induce significant cell death in comparison to the control groups. Radiofrequency radiation was found to be more efficient in vitro, and the treatment efficacy was verified in vivo in a lung carcinoma (3LL) mice model. After a single intratumoral administration of the carrier system combined with radiofrequency radiation, there was clear suppression of the growth of the carcinoma and a prolongation of the survival time of the animals. The temperature responsive (TR) polymer grafted on the surface of porous silicon nanoparticles (PSi NPs) changes its conformation in response to the heating induced by infrared or radiofrequency radiation. The conformation change allows the loaded doxorubicin to escape from the pores, achieving controlled drug release from TR PSi NPs, which displayed efficacy against malignant cells both in vitro and in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Internally gas-cooled radiofrequency applicators as an alternative to conventional radiofrequency and microwave ablation devices: An in vivo comparison

    Energy Technology Data Exchange (ETDEWEB)

    Rempp, Hansjörg, E-mail: Hansjoerg.rempp@med.uni-tuebingen.de [Eberhard Karls University of Tübingen, Tübingen University Hospital, Department of Diagnostic and Interventional Radiology, Hoppe-Seyler-Straße 3, Tübingen, 72076 (Germany); Voigtländer, Matthias [ERBE Elektromedizin GmbH, Waldhörnlestraße 17, 72072 Tübingen (Germany); Schenk, Martin [Eberhard Karls University of Tuebingen, Tübingen University Hospital, Department of General, Visceral and Transplant Surgery, Hoppe-Seyler-Straße 3, 72076 Tübingen (Germany); Enderle, Markus D. [ERBE Elektromedizin GmbH, Waldhörnlestraße 17, 72072 Tübingen (Germany); Scharpf, Marcus [Eberhard Karls University of Tuebingen, Insitute of Pathology, Department on General Pathology and Pathological Anatomy, Liebermeisterstraße 8, 72076 Tübingen (Germany); Greiner, Tim O. [Eberhard Karls University of Tuebingen, Tübingen University Hospital, Department of General, Visceral and Transplant Surgery, Hoppe-Seyler-Straße 3, 72076 Tübingen (Germany); Neugebauer, Alexander [ERBE Elektromedizin GmbH, Waldhörnlestraße 17, 72072 Tübingen (Germany); and others

    2013-08-15

    Purpose: To test the efficacy of internally CO{sub 2}-cooled radiofrequency (RF) ablation in vivo and to compare its effectiveness to a standard water-cooled RF probe and to a gas-cooled microwave (MW) device. Method and materials: 49 ablations were performed on 15 pigs under general anesthesia using 15G monopolar CO{sub 2}-cooled RF applicators, 17G monopolar water-cooled RF applicators and 15G internally CO{sub 2}-cooled microwave devices. The power of the MW device was 45 W, the current of the gas-cooled RF device was 1200–1600 mA. At the water-cooled RF probe, maximum power of 200 W was set. Ablation time was 15 min. The short and long axes of the ablation zone were measured. Histological analyses and NADH-staining were performed. The diameters and the ablation volumes were compared using an analysis of variance. Results: No spots of untreated tissue were observed close to the cooled needle track in any of the ablation zones. The largest short axis diameter was 3.4 ± 0.5 cm achieved with the gas-cooled monopolar applicator. With the water-cooled applicators, short axis diameter was significantly smaller, reaching 2.5 ± 0.4 cm. Gas-cooled MW probes achieved 2.9 ± 1.0 cm. The largest ablation volume was 31.5 ± 12 ml (gas-cooled RF), and the smallest was 12.7 ± 4 ml (water-cooled RF). Short/long axis ratio was largest for gas-cooled RF probes with 0.73 ± 0.08 versus 0.64 ± 0.04 for the water-cooled probes and 0.49 ± 0.25 for the microwave applicator. Conclusion: Gas-cooled RF applicators may have a higher potential for effective destruction of liver lesions than comparable water-cooled RF systems, and may be an alternative to standard RF and MW ablation devices.

  6. Transurethral radiofrequency collagen denaturation for the treatment of women with urinary incontinence.

    Science.gov (United States)

    Kang, Diana; Han, Julia; Neuberger, Molly M; Moy, M Louis; Wallace, Sheila A; Alonso-Coello, Pablo; Dahm, Philipp

    2015-03-18

    Transurethral radiofrequency collagen denaturation is a relatively novel, minimally invasive device-based intervention used to treat individuals with urinary incontinence (UI). No systematic review of the evidence supporting its use has been published to date. To evaluate the efficacy of transurethral radiofrequency collagen denaturation, compared with other interventions, in the treatment of women with UI.Review authors sought to compare the following.• Transurethral radiofrequency collagen denaturation versus no treatment/sham treatment.• Transurethral radiofrequency collagen denaturation versus conservative physical treatment.• Transurethral radiofrequency collagen denaturation versus mechanical devices (pessaries for UI).• Transurethral radiofrequency collagen denaturation versus drug treatment.• Transurethral radiofrequency collagen denaturation versus injectable treatment for UI.• Transurethral radiofrequency collagen denaturation versus other surgery for UI. We conducted a systematic search of the Cochrane Incontinence Group Specialised Register (searched 19 December 2014), EMBASE and EMBASE Classic (January 1947 to 2014 Week 50), Google Scholar and three trials registries in December 2014, along with reference checking. We sought to identify unpublished studies by handsearching abstracts of major gynaecology and urology meetings, and by contacting experts in the field and the device manufacturer. Randomised and quasi-randomised trials of transurethral radiofrequency collagen denaturation versus no treatment/sham treatment, conservative physical treatment, mechanical devices, drug treatment, injectable treatment for UI or other surgery for UI in women were eligible. We screened search results and selected eligible studies for inclusion. We assessed risk of bias and analysed dichotomous variables as risk ratios (RRs) with 95% confidence intervals (CIs) and continuous variables as mean differences (MDs) with 95% CIs. We rated the quality of

  7. Realisation of a linear electron accelerator. Application to the production of millimetre wavelength waves; Realisation d'un accelerateur lineaire d'electrons. Application a la production d'ondes millimetriques

    Energy Technology Data Exchange (ETDEWEB)

    Combe, Rene

    1956-06-27

    In the first part of this research thesis, the author reports the development of a linear electron accelerator with a presentation of charged waveguides which are their main components. He also proposes a recall of the charged waveguide theory, an overview of some experimental guides, a description of the calculation method, and reports the actual realisation of the accelerator waveguide. The apparatus is precisely described, and results obtained during tests are presented. The second part of the thesis addresses the study of millimetre wavelength waves. It reports the study of the electron movement in a sinusoidal inverter, and in a helical inverter (a solenoid in which the electron has a helical trajectory). Then, the author proposes a detailed presentation of electron radiation theory: fundamental wavelength, total radiated power, angular and spectral distribution of radiation. The author finally reports a comparison between radiations obtained with different devices [French] La premiere partie de ce memoire traite precisement de l'etude et de la construction de notre accelerateur lineaire d'electrons, le chapitre I etant consacre aux fluides d'ondes charges, qui en constituent l'element essentiel. Apres un rappel de la theorie de ces guides, on expose quelques contributions theoriques, on etudie un certain nombre de guides experimentaux, et on decrit la methode de calcul et la realisation du guide de l'accelerateur. Le chapitre II renferme la description de l'appareil et l'expose des resultats obtenus lors de ses essais. La deuxieme partie: recherches sur les ondes millimetriques, commence (chapitre III) par l'etude du mouvement de l'electron dans un ondulateur sinusoidal, ou dans un ondulateur helicoidal, solenoide, dans lequel l'electron decrit une trajectoire en helice: nous etudions concurremment les deux dispositifs. Le chapitre IV contient la theorie detaillee du rayonnement de l'electron: longueur d'onde fondamentale, puissance totale rayonnee

  8. Emision of Cl2* molecules in a barrier discharge

    International Nuclear Information System (INIS)

    Avdeev, S M; Erofeev, M V; Sosnin, E A; Tarasenko, V F

    2008-01-01

    The energy and spectral parameters of emission of a barrier discharge in chlorine and its mixtures with inert gases are studied experimentally. The barrier discharge in chlorine was homogeneous at pressures up to ∼9 Torr and its spectrum contained the 3 Π 2g → 3 Π 2u , 3 Π 2g → 3 Σ 2u + and 1 Σ u + → 1 Σ g + bands of Cl 2 * molecules. After the addition of an inert gas, the 257.8-nm 3 Π 2g → 3 Π 2u band made the main contribution to the spectrum. The maximum efficiency and power of the Cl 2 excilamp were obtained for the chlorine-argon mixture and amounted to 0.7% and 1.3 W, respectively. (laser applications and other topics in quantum electronics)

  9. Combined use of radioiodine therapy and radiofrequency ablation in treating postsurgical thyroid remnant of differentiated thyroid carcinoma

    Directory of Open Access Journals (Sweden)

    Bin Long

    2015-01-01

    Conclusion: Combined use of RAI therapy and radiofrequency ablation in treating excessive postsurgical thyroid remnant of DTC can be an effective approach and avoids re-operation. Long-term efficacy monitoring would further determine its feasibility.

  10. Clinical application of radiofrequency ablation combined with bronchial artery infusion of docetaxel in treating non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lu Xiong; Chen Fang; Lin Yun; Tan Taikang; Wei Wei

    2010-01-01

    Objective: To discuss the clinical application of radiofrequency ablation combined with bronchial artery infusion of docetaxel in treating non-small cell lung cancer and to summarize the experience of using this therapy in clinical practice. Methods: Radiofrequency ablation was performed in twenty-one patients with lung cancer. The diagnosis was confirmed by CT-guided percutaneous needle biopsy or bronchoscopic biopsy in all patients. One week after radiofrequency ablation treatment, bronchial artery infusion of docetaxel was conducted. The therapeutic results were observed and evaluated. Results: After the treatment, the lesion's size was markedly reduced and the clinical symptoms were dramatically improved in all patients. Conclusion: Radiofrequency ablation combined with bronchial artery infusion of docetaxel is a safe, effective and simple technique with excellent therapeutic results for the treatment of non-small cell lung cancer. It is really worth popularizing this technique in clinical practice. (authors)

  11. An assessment of potential health effects from exposure to PAVE PAWS low-level phased-array radiofrequency energy

    National Research Council Canada - National Science Library

    Committee to Assess Potential Health Effects from Exposures to PAVE PAWS Low-Level Phased-Array Radiofrequency Energy, National Research Council

    2005-01-01

    .... Air Force Space Command. In 1979, the National Research Council issued two reports to address concerns from Cape Cod residents about the safety and possible health effects of the radiofrequency energy from the radar...

  12. A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis

    NARCIS (Netherlands)

    E.S. Shin (Eun-Seok); H.M. Garcia-Garcia (Hector); P.W.J.C. Serruys (Patrick)

    2010-01-01

    textabstractAlthough previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that of lumen contour, because of the limited IVUS resolution. The purpose of this study was

  13. Radiofrequency sensory ablation as a treatment for symptomatic unilateral lumbosacral junction pseudarticulation (Bertolotti's syndrome): a case report.

    Science.gov (United States)

    Burnham, Robert

    2010-06-01

    Describe the clinical presentation, diagnostic evaluation, and successful treatment of a case of symptomatic unilateral lumbosacral junction pseudarticulation using a novel radiofrequency nerve ablation technique. A 56-year-old female patient who had suffered with low back and right upper buttock pain for 16 years experienced incomplete relief with L4/5 facet joint radiofrequency ablation. She was found to have an elongated right L5 transverse process that articulated with the sacral ala (Bertolotti's syndrome). Fluoroscopically guided local anesthetic/corticosteroid injection into the pseudarthrosis eliminated her residual right buttock pain for the duration of the local anesthetic only. Complete pain relief was achieved by injecting local anesthetic circumferentially around the posterior pseudarthrosis articular margin. Accordingly, bipolar radiofrequency strip thermal lesions were created at the same locations. Complete pain relief and full restoration of function was achieved for 16 months postprocedure. This case report describes a novel radiofrequency technique for treating symptomatic lumbosacral junction pseudarticulation that warrants further evaluation.

  14. Endovascular ultrasound for renal sympathetic denervation in patients with therapy-resistant hypertension not responding to radiofrequency renal sympathetic denervation.

    Science.gov (United States)

    Stiermaier, Thomas; Okon, Thomas; Fengler, Karl; Mueller, Ulrike; Hoellriegel, Robert; Schuler, Gerhard; Desch, Steffen; Lurz, Philipp

    2016-06-12

    Recent studies have reported a considerable number of non-responders after renal sympathetic de-nervation (RSD) with radiofrequency technology. Here we report our results of repeat RSD using ultrasound in these patients. A cohort study was performed in patients who underwent ultrasound RSD after non-response to RSD with radiofrequency. Non-response was defined as mean daytime systolic blood pressure ≥140 mmHg and/or a reduction of ≤10 mmHg in ambulatory blood pressure measurement (ABPM) ≥6 months after radiofrequency denervation. ABPM was recorded at baseline, post radiofrequency RSD as well as at three and six months post ultrasound RSD. A total of 24 non-responders underwent retreatment with the ultrasound device at a mean 15.3±8.2 months after radiofrequency RSD. Ultrasound RSD was performed successfully in all patients without severe adverse events. Mean daytime systolic blood pressure changed from 161.7±14.6 mmHg at baseline to 158.5±9.5 mmHg post radiofrequency RSD and to 150.5±10.4 mmHg and 151.6±11.0 mmHg at three and six months, respectively, post ultrasound RSD (pmeasures analysis of variance). The main results of post hoc testing were as follows: baseline versus post radiofrequency RSD, p=0.83; baseline versus three months post ultrasound RSD, p=0.01; and baseline versus six months post ultrasound RSD, p=0.04. Ultrasound RSD appears to be safe and an effective therapeutic approach in patients not responding to previous RSD with radiofrequency technology.

  15. Radiofrequency catheter ablation: A study concerning electrode configuration, lesion size and potential complications

    International Nuclear Information System (INIS)

    Anfinsen, Ole-Gunnar

    1999-01-01

    The study was performed to evaluate different methods of increasing the lesion size in radiofrequency catheter ablation, which is an important issue as the clinical indications for RF ablation are extended. The safety aspects of RF ablation are also studied, both with standard catheters and with experimental ones. The studies have been performed in vitro, in an animal model and in patients. The results are presented in 5 papers with titles of: 1) 'Radiofrequency catheter ablation of procine right atrium: Increased lesion size with bipolar two-catheter technique compared to unipolar application in vitro and in vivo. 2) Bipolar radiofrequency catheter ablation creates confluent lesions at a larger interelectrode spacing than does unipolar ablation from two electrodes in porcine heart. 3) Temperature-controlled radiofrequency catheter ablation with a 10 mm tip electrode creates larger lesions without charring in the porcine heart. 4) Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor. 5) The activation of platelet function, coagulation and fibrinolysis during radiofrequency catheter ablation in heparin zed patients. The main conclusions are: 1) Large RF lesions may be created either by using larger electrodes and more power in the unipolar mode, or by changing the electrode configuration and thereby the geometry of the electrical field during RF current delivery. Both the 10 mm unipolar, the dielectrode and the bipolar mode showed feasible in porcine IVC-TV isthmus and right atrial free wall ablations, but the gain in lesion length was most pronounced in the bipolar mode. 2) Crater formation and intramural haemorrhages may complicate RF ablation using high current density in the right atrial free wall. In our study this was observed with 10 mm unipolar and bipolar two-catheter ablation. Phrenic nerve injury and lesions of the adjacent pulmonary tissue are risks related to

  16. Radiofrequency ablation of liver tumors by using monopolar perfusion electrode:an analysis of therapeutic results

    International Nuclear Information System (INIS)

    Luo Rongguang; Gu Yangkui; Gao Fei; Zhang Liang; Zhao Ming; Fan Weijun; Wu Peihong; Huang Jinhua

    2010-01-01

    Objective: To investigate the clinical value of CT-guided radiofrequency ablation by using monopolar perfusion electrode in treating liver tumors. Methods: From January 2008 to December 2008, 24 patients with 37 lesions of liver tumors were treated with radiofrequency ablation by using monopolar perfusion electrode (RITA UniBlate). Of the 24 patients,solitary lesion was seen in 14, two lesions in 7 and three lesions in 3. Among 37 lesions,the maximum diameter of the lesion ≤ 3 cm, 3.1∼5 cm and > 5 cm was determined in 24, 8 and 5, respectively. The changes of the tumor size and the AFP level were observed. A follow-up lasting for 12 months was conducted. Results: After radiofrequency ablation twenty-two lesions (22/37, 59.5%) were completely ablated, of which nineteen tumors (19/24, 79.2%) were smaller than 3 cm in diameter, two tumors (2 / 8, 25%) had a diameter between 3.1 cm and 5 cm, one tumor (1 / 5, 20%) was larger than 5 cm. Fifteen tumors (15 / 37, 40.5%) were not completely ablated. During the follow-up period of 12 months, fifteen patients (15 / 24, 62.5%) remained alive and nine patients died, of whom the survival time was less than 6 months in six and was 6 -12 months in 4. After radiofrequency ablation, the AFP level decreased to normal level in 5 patients (5 / 10, 50%), and mild decrease of AFP, but still higher than normal,was seen in 3 patients (3 / 10, 30%). Of 10 patients who had a positive AFP test, 2 (2 / 10, 10%) showed a continuous rise in the AFP level. After radiofrequency ablation, one patient developed a minor hepatic subcapsular bleeding,and all patients complained of different degrees of fever and upper abdominal pain. Conclusion: CT-guided radiofrequency ablation by using monopolar perfusion electrode is a minimally-invasive technique with reliable short-term results and fewer complications. Therefore, it is a safe and effective local treatment for liver cancer. For tumors smaller than 3 cm in diameter complete ablation can be

  17. Radiofrequency catheter ablation: A study concerning electrode configuration, lesion size and potential complications

    Energy Technology Data Exchange (ETDEWEB)

    Anfinsen, Ole-Gunnar

    1999-07-01

    The study was performed to evaluate different methods of increasing the lesion size in radiofrequency catheter ablation, which is an important issue as the clinical indications for RF ablation are extended. The safety aspects of RF ablation are also studied, both with standard catheters and with experimental ones. The studies have been performed in vitro, in an animal model and in patients. The results are presented in 5 papers with titles of: 1) 'Radiofrequency catheter ablation of procine right atrium: Increased lesion size with bipolar two-catheter technique compared to unipolar application in vitro and in vivo. 2) Bipolar radiofrequency catheter ablation creates confluent lesions at a larger interelectrode spacing than does unipolar ablation from two electrodes in porcine heart. 3) Temperature-controlled radiofrequency catheter ablation with a 10 mm tip electrode creates larger lesions without charring in the porcine heart. 4) Radiofrequency catheter ablation in vitro: The difference between tissue and catheter tip temperature depends on location of the temperature sensor. 5) The activation of platelet function, coagulation and fibrinolysis during radiofrequency catheter ablation in heparin zed patients. The main conclusions are: 1) Large RF lesions may be created either by using larger electrodes and more power in the unipolar mode, or by changing the electrode configuration and thereby the geometry of the electrical field during RF current delivery. Both the 10 mm unipolar, the dielectrode and the bipolar mode showed feasible in porcine IVC-TV isthmus and right atrial free wall ablations, but the gain in lesion length was most pronounced in the bipolar mode. 2) Crater formation and intramural haemorrhages may complicate RF ablation using high current density in the right atrial free wall. In our study this was observed with 10 mm unipolar and bipolar two-catheter ablation. Phrenic nerve injury and lesions of the adjacent pulmonary tissue are risks

  18. Métallisation de guide d'onde en matériau composite à matrice époxy par un procédé DLI-MOCVD

    OpenAIRE

    Addou, Fouzi

    2017-01-01

    La fabrication de guides d’ondes à partir d’un matériau composite CFRP isolant, nécessite de rendre la surface interne conductrice électriquement. Cela peut s’effectuer par métallisation, mais des verrous technologiques apparaissent en raison de la géométrie complexe associée à une surface inerte. Le CFRP est composé d’époxy dont la température de transition vitreuse est de 216 °C, ce qui limite le choix des techniques de métallisation. De plus, l’énergie de surface du polymère qui compose la...

  19. Pulsed Dose Radiofrequency Before Ablation of Medial Branch of the Lumbar Dorsal Ramus for Zygapophyseal Joint Pain Reduces Post-procedural Pain.

    Science.gov (United States)

    Arsanious, David; Gage, Emmanuel; Koning, Jonathon; Sarhan, Mazin; Chaiban, Gassan; Almualim, Mohammed; Atallah, Joseph

    2016-01-01

    One of the potential side effects with radiofrequency ablation (RFA) includes painful cutaneous dysesthesias and increased pain due to neuritis or neurogenic inflammation. This pain may require the prescription of opioids or non-opioid analgesics to control post-procedural pain and discomfort. The goal of this study is to compare post-procedural pain scores and post-procedural oral analgesic use in patients receiving continuous thermal radiofrequency ablation versus patients receiving pulsed dose radiofrequency immediately followed by continuous thermal radiofrequency ablation for zygopophaseal joint disease. This is a prospective, double-blinded, randomized, controlled trial. Patients who met all the inclusion criteria and were not subject to any of the exclusion criteria were required to have two positive diagnostic medial branch blocks prior to undergoing randomization, intervention, and analysis. University hospital. Eligible patients were randomized in a 1:1 ratio to either receive thermal radiofrequency ablation alone (standard group) or pulsed dose radiofrequency (PDRF) immediately followed by thermal radiofrequency ablation (investigational group), all of which were performed by a single Board Certified Pain Medicine physician. Post-procedural pain levels between the two groups were assessed using the numerical pain Scale (NPS), and patients were contacted by phone on post-procedural days 1 and 2 in the morning and afternoon regarding the amount of oral analgesic medications used in the first 48 hours following the procedure. Patients who received pulsed dose radiofrequency followed by continuous radiofrequency neurotomy reported statistically significantly lower post-procedural pain scores in the first 24 hours compared to patients who received thermal radiofrequency neurotomy alone. These patients also used less oral analgesic medication in the post-procedural period. These interventions were carried out by one board accredited pain physician at one

  20. Calculation of the energy of particles emitted by the reactions {sup 3}{sub 1}T (d,n) {sup 4}{sub 2}He, D (d,n) {sup 3}{sub 2}He and D (d,p) T; Calcul de l'energie des particules emises par les reactions {sup 3}{sub 1}T (d,n) {sup 4}{sub 2}He, D (d,n) {sup 3}{sub 2}He et D (d,p) T

    Energy Technology Data Exchange (ETDEWEB)

    Oria, M; Sorriaux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    With a view to ease the work of research workers using 150 kV electrostatic accelerators, we have calculated the energy and the emission angle of particles emitted during the reactions {sub 1}{sup 3}T(d,n){sub 2}{sup 4}He, {sub 1}{sup 2}D(d,n){sub 2}{sup 3}He and {sub 1}{sup 2}D(d,p){sub 1}{sup 3}T. The results are classified in tables and arranged according to the acceleration energy of the deuterons. Since the energies considered are relatively low we have limited our study to the non-relativistic domain; this simplification results in a maximum energy variation with respect to the real energy values of 1 per cent. We give also two curves representing the variations in the total cross-sections for the reactions T (d,n){sub 2}{sup 4}He and D (d,n){sub 2}{sup 3}He. (authors) [French] De facon a faciliter la tache des experimentateurs utilisant des accelerateurs electrostatiques de 150 kV, nous avons calcule l'energie et l'angle d'emission des particules emises lors des reactions {sub 1}{sup 3}T(d,n){sub 2}{sup 4}He, {sub 1}{sup 2}D(d,n){sub 2}{sup 3}He and {sub 1}{sup 2}D(d,p){sub 1}{sup 3}T. Les resultats ont ete classes dans des tableaux, et ordonnes en fonction de l'energie d'acceleration des deuterons. Les energies considerees etant relativement peu elevees, nous avons limite notre etude au domaine non relativiste, cette simplification n'entraine qu'une variation maximale de 1 pour cent sur les valeurs reelles des energies. Nous avons joint a ce calcul deux courbes representant la variation des sections efficaces totales des reactions T (d,n){sub 2}{sup 4}He et D (d,n){sub 2}{sup 3}He. (auteurs)