WorldWideScience

Sample records for on-site pafc power

  1. 1000kW on-site PAFC power plant development and demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Satomi, Tomohide; Koike, Shunichi [Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA), Osaka (Japan); Ishikawa, Ryou [New Energy and Industrial Technology Development Organization (NEDO), Tokyo (Japan)

    1996-12-31

    Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA) and New Energy and Industrial Technology Development Organization (NEDO) have been conducting a joint project on development of a 5000kW urban energy center type PAFC power plant (pressurized) and a 1000kW on-site PAFC power plant (non-pressurized). The objective of the technical development of 1000kW on-site PAFC power plant is to realize a medium size power plant with an overall efficiency of over 70% and an electrical efficiency of over 36%, that could be installed in a large building as a cogeneration system. The components and system integration development work and the plant design were performed in 1991 and 1992. Manufacturing of the plant and installation at the test site were completed in 1994. PAC test was carried out in 1994, and generation test was started in January 1995. Demonstration test is scheduled for 1995 and 1996.

  2. Development of on-site PAFC stacks

    Energy Technology Data Exchange (ETDEWEB)

    Hotta, K.; Matsumoto, Y. [Kansai Electric Power Co., Amagasaki (Japan); Horiuchi, H.; Ohtani, T. [Mitsubishi Electric Corp., Kobe (Japan)

    1996-12-31

    PAFC (Phosphoric Acid Fuel Cell) has been researched for commercial use and demonstration plants have been installed in various sites. However, PAFC don`t have a enough stability yet, so more research and development must be required in the future. Especially, cell stack needs a proper state of three phases (liquid, gas and solid) interface. It is very difficult technology to keep this condition for a long time. In the small size cell with the electrode area of 100 cm{sup 2}, gas flow and temperature distributions show uniformity. But in the large size cell with the electrode area of 4000 cm{sup 2}, the temperature distributions show non-uniformity. These distributions would cause to be shorten the cell life. Because these distributions make hot-spot and gas poverty in limited parts. So we inserted thermocouples in short-stack for measuring three-dimensional temperature distributions and observed effects of current density and gas utilization on temperature.

  3. Demonstration of 5MW PAFC power plant

    Energy Technology Data Exchange (ETDEWEB)

    Usami, Yutaka [Phosphoric Acid Fuel Cell Technology Research Association, Osaka (Japan); Takae, Toshio [New Energy and Industrial Technology Development Organization, Tokyo (Japan)

    1996-12-31

    Phosphoric Acid Fuel Cell Technology Research Association, established in May 1991 by Japanese 10 electric power and 4 gas companies, started a new project in 1991 FY, with the object of PAFC realization and aiming the development of 5MW- class PAFC. power plant for urban energy center and 1 MW- class power plant for onsite use. This project is carried out as 6 years plan jointly with New Energy and Industrial Technology Development Organization. The targets of the project are to evaluate and resolve the development task, such as a high reliability, compactness and cost reduction throughout the engineering, manufacturing and field testing of PAFC power plants. PAC tests and power generating test operations of 5MW plant were completed in 1994. Conducting the 2 years continuous operations and studies since 1995, the plant operational performance, system control characteristics, waste heat recovery and environmental advantage will be demonstrated.

  4. Development of a 200kW multi-fuel type PAFC power plant

    Energy Technology Data Exchange (ETDEWEB)

    Take, Tetsuo; Kuwata, Yutaka; Adachi, Masahito; Ogata, Tsutomu [NTT Integrated Information & Energy System Labs., Tokyo (Japan)

    1996-12-31

    Nippon Telegraph and Telephone Corporation (NFT) has been developing a 200 kW multi-fuel type PAFC power plant which can generate AC 200 kW of constant power by switching fuel from pipeline town gas to liquefied propane gas (LPG) and vice versa. This paper describes the outline of the demonstration test plant and test results of its fundamental characteristics.

  5. Demonstration of an on-site PAFC cogeneration system with waste heat utilization by a new gas absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Tatsuo [Tokyo Gas Company, LTD, Tokyo (Japan)

    1996-12-31

    Analysis and cost reduction of fuel cells is being promoted to achieve commercial on-site phosphoric acid fuel cells (on-site FC). However, for such cells to be effectively utilized, a cogeneration system designed to use the heat generated must be developed at low cost. Room heating and hot-water supply are the most simple and efficient uses of the waste heat of fuel cells. However, due to the short room-heating period of about 4 months in most areas in Japan, the sites having demand for waste heat of fuel cells throughout the year will be limited to hotels and hospitals Tokyo Gas has therefore been developing an on-site FC and the technology to utilize tile waste heat of fuel cells for room cooling by means of an absorption refrigerator. The paper describes the results of fuel cell cogeneration tests conducted on a double effect gas absorption chiller heater with auxiliary waste heat recovery (WGAR) that Tokyo Gas developed in its Energy Technology Research Laboratory.

  6. Evaluation of the performance degradation at PAFC effect of catalyst degradation on electrode performance

    Energy Technology Data Exchange (ETDEWEB)

    Nishizaki, K.; Uchida, H.; Watanabe, M. [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    Aiming commercialization of Phosphoric Acid Fuel Cell (PAFC) power plant, many researches and developments have been contributed. Over 20000 hours operations have been demonstrated by many PAFC power plants. But there is no effective method for the estimation of lifetime of electrochemical cells without a practical long-term operation. Conducted by New Energy and Industrial Technology Development Organization (NEDO), cooperative research projects aiming development of PAFC lifetime estimation method have started since 1995 FY in Japan. As part of this project, this work has been performed to clarify basic phenomena of the performance degradation at PAFCs jointly by Yamanashi University, Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA) and PAFC manufacturers (Toshiba Co., Mitsubishi Electric Co, Fuji Electric Co.). Among several main causes of the cell performance degradation, effects of catalyst degradation (reduction in metal surface area, dealloying, changes in catalyst support) on PAFC cathode performances are discussed in this work.

  7. Development of the electric utility dispersed use PAFC stack

    Energy Technology Data Exchange (ETDEWEB)

    Horiuchi, Hiroshi; Kotani, Ikuo [Mitsubishi Electric Co., Kobe (Japan); Morotomi, Isamu [Kansai Electric Power Co., Hyogo (Japan)] [and others

    1996-12-31

    Kansai Electric Power Co. and Mitsubishi Electric Co. have been developing the electric utility dispersed use PAFC stack operated under the ambient pressure. The new cell design have been developed, so that the large scale cell (1 m{sup 2} size) was adopted for the stack. To confirm the performance and the stability of the 1 m{sup 2} scale cell design, the short stack study had been performed.

  8. Influence of impurity gases and operating conditions on PAFC performance

    Energy Technology Data Exchange (ETDEWEB)

    Hirai, K.; Iwasa, N.; Suzuki, M.; Okada, O. [Osaka Gas Co., Ltd. (Japan)] [and others

    1996-12-31

    On-site Phosphoric Acid Fuel Cell (PAFC) Cogeneration system is installed at various test sites, such as at underground parking lot, within chemical plant premises and near urban streets. Since in the current PAFC system, cathode air is supplied to the cell with no particular pretreatment, impurity gases in the air might influence on cell performance. We have investigated the influence of various impurity gases in the cathode gas, on sub-scale single cells, and have found that NO{sub 2}, SO{sub 2} and toluene affect negatively on cell performance. The results of these experiments and the conceivable mechanism of these effects on cell degradation are reported. We have also investigated the influence of other operating parameters, such as temperature, current density, fuel utilization on cell performance. From these experiments, we have found that operating temperature is a significant factor, which mainly determines cell voltage decline rate. The results of sub-scale single cell tests and a short-stack verification test are also reported.

  9. 78 FR 1265 - Dana Holding Corporation; Power Technologies Group Division; Including On-Site Leased Workers...

    Science.gov (United States)

    2013-01-08

    ... Employment and Training Administration Dana Holding Corporation; Power Technologies Group Division; Including... Technologies Group Division, Milwaukee, Wisconsin (subject firm). The worker group includes on-site leased... Company, Power Technologies Group Division, Milwaukee, Wisconsin, who were engaged in employment...

  10. On-site Testing and PD Diagnosis of High Voltage Power Cables

    NARCIS (Netherlands)

    Gulski, E.; Cichecki, P.; Wester, F.; Smit, J.J.; Bodega, R.; Hermans, T.J.W.H.; Seitz, P.P.; Quak, B.; De Vries, F.

    2008-01-01

    In addition to after-laying of new-installed high voltage (HV) power cables the use of on-site non-destructive on-site testing and diagnosis of service aged power cables is becoming an important issue to determine the actual condition of the cable systems and to determine the future performances. In

  11. Evaluation of polyaluminium ferric chloride (PAFC) as a composite coagulant for water and wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    Gao, B.; Yue, Q.; Miao, J. [Shandong University, Shandong (China)

    2003-07-01

    Coal gangue is a kind of waste from coal mine processing. Polyaluminium ferric chloride (PAFC), a new type of inorganic composite coagulant, was prepared by using the waste from the Mineral Bureau of Yanzhou, China, hydrochloric acid and calcium carbonate as raw materials. The relationship between the stability of ferric ion and the ionic strength of solution was investigated. The zeta potential of PAFC hydrolysis products of PAFC and the coagulation performances under different pH value were discussed. The turbidity removal properties of PAFC, polyaluminium (PAC) and polyferric sulfate (PFS) were compared, and the color removal effect of PAFC for the wastewater containing suspended dyes was also tested. In addition, the coagulation performance of PAFC for actual wastewaters from petrochemical plant, iron and steel plant, and coal mining processing was evaluated. The experimental results suggest that PAFC took a maximum value of zeta potential at about pH 5.8 on the positive side. Compared with PAC, PAFC gives better turbidity removal performance in the range of pH from 7.0 to 8.4. PAFC gives good color removal performance on suspension dyes. PAFC also gives good wastewater purifying results for the actual wastewater.

  12. Assessment of On-Site Power Opportunities in the Industrial Sector

    Energy Technology Data Exchange (ETDEWEB)

    Bryson, T.

    2001-10-08

    The purpose of this report is to identify the potential for on-site power generation in the U.S. industrial sector with emphasis on nine industrial groups called the ''Industries of the Future'' (IOFs) by the U.S. Department of Energy (DOE). Through its Office of Industrial Technologies (OIT), the DOE has teamed with the IOFs to develop collaborative strategies for improving productivity, global competitiveness, energy usage and environmental performance. Total purchases for electricity and steam for the IOFs are in excess of $27 billion annually. Energy-related costs are very significant for these industries. The nine industrial groups are (1) Agriculture (SIC 1); (2) Forest products; (3) Lumber and wood products (SIC 24); (4) Paper and allied products (SIC 26); (5) Mining (SIC 11, 12, 14); (6) Glass (SIC 32); (7) Petroleum (SIC 29); (8) Chemicals (SIC 28); and (9) Metals (SIC 33): Steel, Aluminum, and Metal casting. Although not currently part of the IOF program, the food industry is included in this report because of its close relationship to the agricultural industry and its success with on-site power generation. On-site generation provides an alternative means to reduce energy costs, comply with environmental regulations, and ensure a reliable power supply. On-site generation can ease congestion in the local utility's electric grid. Electric market restructuring is exacerbating the price premium for peak electricity use and for reliability, creating considerable market interest in on-site generation.

  13. 76 FR 65212 - Caterpillar, Inc., Large Power Systems Division, Including On-Site Leased Workers From Gray...

    Science.gov (United States)

    2011-10-20

    ... Employment and Training Administration Caterpillar, Inc., Large Power Systems Division, Including On- Site... Adjustment Assistance on November 2, 2009, applicable to Caterpillar, Inc., Large Power Systems Division... Caterpillar, Inc., Large Power Systems Division. The Department has determined that these workers...

  14. Estimation of current density distribution of PAFC by analysis of cell exhaust gas

    Energy Technology Data Exchange (ETDEWEB)

    Kato, S.; Seya, A. [Fuji Electric Co., Ltd., Ichihara-shi (Japan); Asano, A. [Fuji Electric Corporate, Ltd., Yokosuka-shi (Japan)

    1996-12-31

    To estimate distributions of Current densities, voltages, gas concentrations, etc., in phosphoric acid fuel cell (PAFC) stacks, is very important for getting fuel cells with higher quality. In this work, we leave developed a numerical simulation tool to map out the distribution in a PAFC stack. And especially to Study Current density distribution in the reaction area of the cell, we analyzed gas composition in several positions inside a gas outlet manifold of the PAFC stack. Comparing these measured data with calculated data, the current density distribution in a cell plane calculated by the simulation, was certified.

  15. Evaluation of the performance degradation at PAFC effect of electrolyte fill-level on electrode performance

    Energy Technology Data Exchange (ETDEWEB)

    Kitai, Takashi; Uchida, Hiroyuki; Watanabe, Masahiro [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    As a complimentary research project to the demonstration project of 5MW and 1MW PAFC plants, the mechanism and rate of deterioration of the cells and stacks have been studied from 1995 FY, with the objective of establishing an estimation method for the service life-time of the cell stacks. This work has been performed in the Basic Research Project, as part of that project on PAFC`s, selecting four subjects (Electrocatalysts degradation, Electrolyte fill-level, Cell material corrosion, Electrolyte loss) as the essential factors relating to the life-time. In this report, we will exhibit the effect of the electrolyte fill-level on the electrode performances.

  16. 75 FR 41895 - Emerson Power Transmission, a Division of Emerson Electric Co., Including On-Site Leased From...

    Science.gov (United States)

    2010-07-19

    ... Employment and Training Administration Emerson Power Transmission, a Division of Emerson Electric Co..., 2010, applicable to workers of Emerson Power Transmission, a Division of Emerson Electric Co... were employed on-site at the Ithaca, New York, location of Emerson Power Transmission, a Division...

  17. 76 FR 27366 - Chrysler Group, LLC, Power Train Division, Mack Avenue Engine Plants #1 And #2, Including On-Site...

    Science.gov (United States)

    2011-05-11

    ... Employment and Training Administration Chrysler Group, LLC, Power Train Division, Mack Avenue Engine Plants 1... Group, LLC, Power Train Division, Mack Avenue Engine Plant 1, including on-site leased workers of... period at the Mack Avenue Engine Plant 2, Detroit, Michigan location of Chrysler Group, LLC, Power...

  18. Investment in volume building: the `virtuous cycle' in PAFC

    Science.gov (United States)

    Whitaker, Rick

    The world's first commercial fuel cell power plant - the 200-kW PC25™ - works. That is very good news for everyone interested in the market introduction of fuel cell power. Reaching this point has taken years of intensive R&D investment. However, we are finding out now that the investment game in phosphoric acid on-site power is far from over. It has only entered a new phase, where we must invest in creating market volume, to reduce our costs and increase volume. It is in initiating this `Virtuous Cycle' that International Fuel Cells (IFC), through its stationary power subsidiary ONSI, is devoting almost all its time and investment today.

  19. 76 FR 22729 - Chrysler Group, LLC, Power Train Division, Mack Avenue Engine Plant #1, Including On-Site Leased...

    Science.gov (United States)

    2011-04-22

    ... Employment and Training Administration Chrysler Group, LLC, Power Train Division, Mack Avenue Engine Plant 1... to Apply for Worker Adjustment Assistance on April 6, 2011, applicable to workers of Chrysler Group, LLC, Power Train Division, Mack Avenue Engine Plant 1, including on-site leased workers of...

  20. On the size effect in PAFC grid-connected plant

    Energy Technology Data Exchange (ETDEWEB)

    Bizzarri, Giacomo [Dipartimento di Architettura, Universita di Ferrara, Via Quartieri 8, 44100 Ferrara (Italy)

    2006-07-15

    This article is the final part of a research project aimed at exploring the potential of energy retrofit through fuel cell hybrid plants. If previous papers revealed the considerable environmental benefits in terms of primary energy saving and pollutant emission reduction that could be achieved by such a shift, they also demonstrated that these plants are feasible only when appropriate financial incentives are given. The identification of the best PAFC plant size thus represents a key target resulting in significant economic savings. Therefore, in this paper, several hybrid scenarios are investigated, taking nine hospitals of Ferrara province (Italy) as the study sample. Investigations reveal that the more the proper sizing is carried out in search of the highest environmental and energy benefits, the higher the financial returns will be. The knowledge of this size effect could be adopted as a useful design guideline and can be taken as a first criterion for the adoption of these systems. A first methodology for the proper sizing of fuel cell plants is suggested. (author)

  1. Evaluation of the performance degradation at PAFC effect of operating conditions on acid loss

    Energy Technology Data Exchange (ETDEWEB)

    Miyoshi, Hideaki; Uchida, Hiroyuki; Watanabe, Masahiro [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    As a complimentary research project to the demonstration project of 5MW and 1 MW PAFC plants, the mechanism and rate of deterioration of the cells and stacks have been studied from 1995 FY conducted by NEDO, with the objective of establishing an estimation method for the service life-time of the cell stacks. As part of this project, this work has been performed to clarify basic phenomena of the performance degradation at PAFCs jointly by Yamanashi University, PAFC-TRA and PAFC manufacturers. The acid loss into exhaust gases is one of life limiting factors in PAFCs. To design the cells of long-life, it is important to estimate the phosphoric acid loss and to contrive ideas eliminating it. With the objective of obtaining basic data for simulating the acid loss in the large size cells, the effect of the operating conditions on the acid loss into exhaust gases has been studied experimentally by using a single cell with an active electrode area of 100 cm{sup 2}.

  2. Guide to purchasing green power. Renewable electricity, renewable energy certificates and on-site renewable generation

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-09-30

    The Guide to Purchasing Green Power is intended for organizations that are considering the merits of buying green power as well as those that have decided to buy it and want help doing so. The Guide was written for a broad audience, including businesses, government agencies, universities, and all organizations wanting to diversify their energy supply and to reduce the environmental impact of their electricity use.The Guide provides an overview of green power markets and describes the necessary steps to buying green power. This section summarizes the Guide to help readers find the information they need.

  3. Feasibility of Thulium-170, Produced on Site, for Radioisotope Power Generation

    Science.gov (United States)

    Brennan, Charles; Mathews, Kirk

    1994-07-01

    Thulium-170 has been suggested as a replacement for 238Pu jn some radioisotope power generation applications. The proposed approach is to activate 169Tm within the core or reflector of a stationary site power nuclear reactor at a Lunar or Mars outpost. The 170Tm so produced offers high theoretical power densities without the toxicity, availability, and nuclear launch problems of plutonium (only stable 169Tm would be launched). We examined issues raised by previous studies. It would be desirable to activate the thulia repeatedly. The ORIGEN2 code was used to model repeated irradiation/decay of thulium sesquioxide. We found no substantial buildup of neutron absorbing activation products that would prohibit repeated irradiation of the sample. Throughout the life of the sample, the dominant activity was the 170Tm. There was no buildup of toxic substances. At end of life, the sample would be Class B waste. Another advantage of recycling is that, for the first several recyclings, recycled targets achieve the same power level as fresh ones, but with shorter activation periods (or higher power levels with the same activation periods). However, sufficient 170Tm could not be produced. Using neutron conservation arguments, we developed an absolute upper bound on l70Tm power production of 1/3 watt thermal per kilowatt thermal of reactor power. Realistic values are much lower. Thus, the envisioned application appears impractical, although limited uses for 170Tm power might be found.

  4. 77 FR 51064 - Dana Holding Corporation, Power Technologies Group Division, Including On-Site Leased Workers...

    Science.gov (United States)

    2012-08-23

    ... Employment and Training Administration Dana Holding Corporation, Power Technologies Group Division, Including... Holding Corporation, Power Technologies Group Division, Milwaukee, Wisconsin (subject firm). The negative... competitive articles) in 2011 and 2012, loss of business with a firm that employed a worker group eligible...

  5. Study on Site Specific Design Earthquake Ground Motion of Nuclear Power Plants in China1

    Institute of Scientific and Technical Information of China (English)

    Zhou Bochang; Li Xiaojun; Li Yaqi

    2008-01-01

    The main technical backgrounds and requirements are introduced with regard to earthquake ground motion design parameters in several domestic and American standards,codes and guides involved in the seismic analysis and design activities of nuclear power plants in China.Based on the research results from site seismic safety evaluation of domestic nuclear power plant projects in the last years,characteristics and differences of site specific design spectra are analyzed in comparison with standard response spectra,and the suitability of standard response spectra for domestic nuclear power plant projects is discussed.

  6. Develop and test fuel cell powered on-site integrated total energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Kaufman, A.; Werth, J.

    1988-12-01

    This report describes the design, fabrication and testing of a 25kW phosphoric acid fuel cell system aimed at stationary applications, and the technology development underlying that system. The 25kW fuel cell ran at rated power in both the open and closed loop mode in the summer of 1988. Problems encountered and solved include acid replenishment leakage, gas cross-leakage and edge-leakage in bipolar plates, corrosion of metallic cooling plates and current collectors, cooling groove depth variations, coolant connection leaks, etc. 84 figs., 7 tabs.

  7. Stationary power fuel cell commercialization status worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Williams, M.C. [Dept. of Energy, Morgantown, WV (United States)

    1996-12-31

    Fuel cell technologies for stationary power are set to play a role in power generation applications worldwide. The worldwide fuel cell vision is to provide powerplants for the emerging distributed generation and on-site markets. Progress towards commercialization has occurred in all fuel cell development areas. Around 100 ONSI phosphoric acid fuel cell (PAFC) units have been sold, with significant foreign sales in Europe and Japan. Fuji has apparently overcome its PAFC decay problems. Industry-driven molten carbonate fuel cell (MCFC) programs in Japan and the U.S. are conducting megawatt (MW)-class demonstrations, which are bringing the MCFC to the verge of commercialization. Westinghouse Electric, the acknowledged world leader in tubular solid oxide fuel cell (SOFC) technology, continues to set performance records and has completed construction of a 4-MW/year manufacturing facility in the U.S. Fuel cells have also taken a major step forward with the conceptual development of ultra-high efficiency fuel cell/gas turbine plants. Many SOFC developers in Japan, Europe, and North America continue to make significant advances.

  8. Status of commercial phosphoric acid fuel cell power plant system development

    Science.gov (United States)

    Warshay, M.

    1987-01-01

    A technology development and commercial feasibility evaluation is presented for phosphoric acid fuel cells (PAFCs) applicable to electric utility operations. The correction of identified design deficiencies in the control card and water treatment subsystems is projected to be able to substantially increase average powerplant availability from the 63 percent achieved in recent field tests of a PAFC system. Current development work is proceeding under NASA research contracts at the output levels of a multimegawatt facility for electric utility use, a multikilowatt on-site integrated energy generation facility, and advanced electrocatalysts applicable to PAFCs.

  9. Evaluation of the performance degradation at PAFC investigation of dealloying process of electrocatalysts with in-situ XRD

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Noriyuki; Uchida, Hiroyuki; Watanabe, Masahiro [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    As a complementary research project to the demonstration project of 5MW and 1 MW PAFC plants, the mechanism and rate of deterioration of the cells and stacks have been studied from 1995 FY, with the objective of establishing an estimation method for the service life-time of the cell stacks. This work has been performed in the Basic Research Project, as part of that project on PAFC`s, selecting four subjects (Electrocatalysts degradation, Electrolyte fill-level, Cell material corrosion, Electrolyte loss) as the essential factors relating to the life-time. In this study, the effect of temperature and potential on the dealloying process of electrocatalysts was examined in H{sub 3}PO{sub 4} electrolyte with X-ray diffraction measurement.

  10. 50 kW on-site concentrating solar photovoltaic power system. Phase I: design. Final report, 1 June 1978-28 February 1979

    Energy Technology Data Exchange (ETDEWEB)

    Pittman, P F

    1979-03-30

    This contract is part of a three phase program to design, fabricate, and operate a solar photovoltaic electric power system with concentrating optics. The system will be located beside a Local Operating Headquarters of the Georgia Power Company in Atlanta, Georgia and will provide part of the power for the on-site load. Fresnel lens concentrators will be used in 2-axis tracking arrays to focus solar energy onto silicon solar cells producing a peak power output of 56 kW. The present contract covers Phase I which has as its objective the complete design of the system and necessary subsystems.

  11. Long-term commitment of Japanese gas utilities to PAFCs and SOFCs

    Science.gov (United States)

    Matsumoto, Kiyokazu; Kasahara, Komei

    Tokyo Gas and Osaka Gas have been committed to addressing the energy- and environment-related issues of Japan through promotion of natural gas, an energy friendly to the environment. Being aware of the diversifying market needs (e.g. efficient energy utilization, rising demand for electricity, etc.), active efforts have been made in marketing gas-fired air-conditioning and co-generation systems. In this process, a high priority has also been placed on fuel cells, particularly for realizing their market introduction. Since their participation in the TARGET Program in USA in 1972, the two companies have been involved with the field testing and operation of phosphoric acid fuel cells (PAFCs), whose total capacity has amounted to 12.4 MW. The two companies have played a vital role in promoting and accelerating fuel cell development through the following means: (1) giving incentives to manufacturers through purchase of units and testing, (2) giving feedback on required specifications and technical problems in operation, and (3) verifying and realizing long-term operation utilizing their maintenance techniques. It has been expected that the primary goal of the cumulative operation time of 40 000 h shall be achieved in the near future. Work has also been in progress to develop SOFC. In the joint R&D of a 25-kW solid oxide fuel cell (SOFC) with Westinghouse, the record operation time of 13 000 h has been achieved. Though still twice as much as the average price of competing equipment, the commercialization of PAFCs is close at hand. By utilizing government spending and subsidies for field testing, work will be continued to verify reliability and durability of PAFCs installed at users' sites. These activities have been expected to contribute to realizing economically viable systems and enhance market introduction. The superlative advantages of fuel cells, particularly their environment-friendly qualities, should be best taken advantage of at an appropriate time. In

  12. Proteasome Accessory Factor C (pafC) Is a novel gene Involved in Mycobacterium Intrinsic Resistance to broad-spectrum antibiotics--Fluoroquinolones.

    Science.gov (United States)

    Li, Qiming; Xie, Longxiang; Long, Quanxin; Mao, Jinxiao; Li, Hui; Zhou, Mingliang; Xie, Jianping

    2015-07-03

    Antibiotics resistance poses catastrophic threat to global public health. Novel insights into the underlying mechanisms of action will inspire better measures to control drug resistance. Fluoroquinolones are potent and widely prescribed broad-spectrum antibiotics. Bacterial protein degradation pathways represent novel druggable target for the development of new classes of antibiotics. Mycobacteria proteasome accessory factor C (pafC), a component of bacterial proteasome, is involved in fluoroquinolones resistance. PafC deletion mutants are hypersensitive to fluoroquinolones, including moxifloxacin, norfloxacin, ofloxacin, ciprofloxacin, but not to other antibiotics such as isoniazid, rifampicin, spectinomycin, chloramphenicol, capreomycin. This phenotype can be restored by complementation. The pafC mutant is hypersensitive to H2O2 exposure. The iron chelator (bipyridyl) and a hydroxyl radical scavenger (thiourea) can abolish the difference. The finding that pafC is a novel intrinsic selective resistance gene provided new evidence for the bacterial protein degradation pathway as druggable target for the development of new class of antibiotics.

  13. Ultra Efficient CHHP Using a High Temperature Fuel Cell to Provide On-Site Process Reducing Gas, Clean Power, and Heat

    Energy Technology Data Exchange (ETDEWEB)

    Jahnke, Fred C. [Fuelcell Energy, Inc., Danbury, CT (United States)

    2015-06-30

    FuelCell Energy and ACuPowder investigated and demonstrated the use of waste anode exhaust gas from a high temperature fuel cell for replacing the reducing gas in a metal processing furnace. Currently companies purchase high pressure or liquefied gases for the reducing gas which requires substantial energy in production, compression/liquefaction, and transportation, all of which is eliminated by on-site use of anode exhaust gas as reducing gas. We performed research on the impact of the gas composition on product quality and then demonstrated at FuelCell Energy’s manufacturing facility in Torrington, Connecticut. This demonstration project continues to operate even though the research program is completed as it provides substantial benefits to the manufacturing facility by supplying power, heat, and hydrogen.

  14. Proteasome Accessory Factor C (pafC) Is a novel gene Involved in Mycobacterium Intrinsic Resistance to broad-spectrum antibiotics - Fluoroquinolones

    Science.gov (United States)

    Li, Qiming; Xie, Longxiang; Long, Quanxin; Mao, Jinxiao; Li, Hui; Zhou, Mingliang; Xie, Jianping

    2015-01-01

    Antibiotics resistance poses catastrophic threat to global public health. Novel insights into the underlying mechanisms of action will inspire better measures to control drug resistance. Fluoroquinolones are potent and widely prescribed broad-spectrum antibiotics. Bacterial protein degradation pathways represent novel druggable target for the development of new classes of antibiotics. Mycobacteria proteasome accessory factor C (pafC), a component of bacterial proteasome, is involved in fluoroquinolones resistance. PafC deletion mutants are hypersensitive to fluoroquinolones, including moxifloxacin, norfloxacin, ofloxacin, ciprofloxacin, but not to other antibiotics such as isoniazid, rifampicin, spectinomycin, chloramphenicol, capreomycin. This phenotype can be restored by complementation. The pafC mutant is hypersensitive to H2O2 exposure. The iron chelator (bipyridyl) and a hydroxyl radical scavenger (thiourea) can abolish the difference. The finding that pafC is a novel intrinsic selective resistance gene provided new evidence for the bacterial protein degradation pathway as druggable target for the development of new class of antibiotics. PMID:26139381

  15. 电力安全风险现场监控系统的设计%Research and Design of Power Security Risk on Site Monitoring System

    Institute of Scientific and Technical Information of China (English)

    李琳; 杨涛; 栗庆吉

    2013-01-01

    In light of the better mobility and flexibility of the mobile terminal, this paper proposes a design of Android-based power se-curity risk on site monitoring system. With this software, users can view and operate the instructions during the operation in real-time, monitor and record the information of the job sites, to achieve the assessment, warning and containment of the full state of standardized job security risk. And it comprehensively improves the level of standardization of operating risk containment.%基于移动终端具有移动性、灵活性等优点,提出一种基于Android的电力安全风险现场监控系统。应用该软件系统,用户可在作业过程中对指导书进行实时查看与操作,对作业现场进行实时监控与记录,实现标准化作业安全风险全程实时评估、预警和控制,全面提高标准化作业风险防控水平。

  16. Evaluation of the electrode performance for PAFC by using acid absorption, acceleration and ac-impedance measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang-Soo; Song, Rak-Hyun; Choi, Byung-Woo [Korea Institute of Energy Research, Taejon (Korea, Republic of)] [and others

    1996-12-31

    In PAFC, the degradation on cathode electrode caused by carbon corrosion, platinum dissolution and growth is especially severe. An acceleration test is a good technique for evaluating the degradation of electrode performance, because it does not need long time. Coleman et al used thermal cycling and on-off cycling as an acceleration test. Song et al showed that hydrogen shortage decreased the electrode performance more rapidly than that of air shortage in gas shortage test. Honji et al reported that the rate of coarsening of Pt particle is rapid in open circuit potential and this is one of major causes on the performance degradation of electrode. The cathode performance has been studied by using acid absorption, acceleration and ac-impedance measurements as functions of the polytetrafluoroethylene (PTFE) contents and sintering temperatures of the electrode.

  17. Proteasome Accessory Factor C (pafC) Is a novel gene Involved in Mycobacterium Intrinsic Resistance to broad-spectrum antibiotics - Fluoroquinolones

    OpenAIRE

    Qiming Li; Longxiang Xie; Quanxin Long; Jinxiao Mao; Hui Li; Mingliang Zhou; Jianping Xie

    2015-01-01

    Antibiotics resistance poses catastrophic threat to global public health. Novel insights into the underlying mechanisms of action will inspire better measures to control drug resistance. Fluoroquinolones are potent and widely prescribed broad-spectrum antibiotics. Bacterial protein degradation pathways represent novel druggable target for the development of new classes of antibiotics. Mycobacteria proteasome accessory factor C (pafC), a component of bacterial proteasome, is involved in fluoro...

  18. Installation of an on-site power generation facility using gas as a fuel used as an emergency power supply for fire fighting facilities; Shoboyo setsubinado no hijo dengen ni shiyosuru gas wo nenryo to suru jika hatsuden setsubi no donyu

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K. [Fire Defence Agency, Tokyo (Japan)

    1995-02-01

    This paper summarizes provisions in the Fire Service Law when an on-site power generation facility using gas as a fuel is used as an emergency power supply for fire fighting facilities. The provisions described include the following: regulations on output, number of facilities, operation systems and reserve fuels when installing a power generation facility burning gas exclusively used for normal power use and disaster prevention (a power generation facility using gaseous fuel to be used as a normal and emergency power supply in fire fighting facilities), precautions on operation of these facilities, and evaluation on assurance of stable supply source of the main fuel when no installation of the reserve fuel supply system is required. These regulations take the view of the current status of increase in the structures subjected to fire fighting activities that have installed on-site power generation facilities and cogeneration plants used as ordinary power supply systems. The regulations have become enforced based on the result of discussions on the said power generation facilities burning gas exclusively by the discussion committee for the on-site power generation facilities used as power supply systems for fire fighting facilities in the Nippon Engine Generator Association. 2 figs.

  19. Woking Park PAFC CHP monitoring. Phase 1: Planning, installation and commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Goulding, P.S.; Fry, M.R.

    2003-07-01

    This report covers the planning, installation and commissioning of the first commercially operated fuel cell cogeneration system in the UK. The involvement of Woking Borough Council, its approach to energy efficiency, and the Woking Park site are discussed, and details are given of the PC25/C 200kW fuel cell which is manufactured in the US by UTC Fuel Cells. A description of the Woking Park fuel cell combined heat and power application is presented, and the project economics, specification and tendering are examined. The route taken to planning approval is traced, and installation procedures are outlined. The testing of the phosphoric type PC25 fuel cell cogeneration unit is described, and expected cost and project timescales are noted.

  20. Mobil laboratory for the evaluation on site of the power electric equipment, second generation; Laboratorio movil para la evaluacion en sitio del equipo electrico de potencia, segunda generacion

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo C, Jaime; Escorsa M, Oscar; Estrada G, Javier A; Iturbe F, Marlene; Robles P, Edgar [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2005-07-01

    To the interior of the Generation of Electrical Equipment (GEE) of the Instituto de Investigaciones Electricas, one of the main activities is the diagnosis of the electrical equipment in service. It is well known that the power equipment represents a strong investment that requires the guarantee that it has been manufactured, installed and operated satisfactorily. The life expectancy of these devices is of thirty years, however, many of them already have surpassed that expectation. The rehabilitation or substitution of the equipment implies new investments that are needed for an evaluation of the real condition of the equipment to carry out such rehabilitation. One of the tools necessary to carry out the diagnosis, is a movable laboratory that facilitates all the necessary tools to perform a meticulous analysis that would allow, the client, to make high cost decisions. The application of the movable laboratory is advisable from the inauguration of the equipment. The electrical mechanisms are factory tested in accordance with standardized protocols; it guarantees the fulfillment of the necessary requirements for a correct operation. Nevertheless, when taking them to the assembly site, these are subjected to a series of processes and mechanical stresses that could alter the equipment conditions and its integrity. [Spanish] Al interior de la Generacion de Equipos Electricos (GEE) del Instituto de Investigaciones Electricas, una de las principales actividades es el diagnostico del equipo electrico en servicio. Es bien sabido que los equipos de potencia representan una fuerte inversion que requiere la garantia de que se ha fabricado, instalado y operado satisfactoriamente. La esperanza de vida de estos dispositivos es de treinta anos, no obstante, muchos de ellos ya han superado esa expectativa. La rehabilitacion o sustitucion de equipos, implica nuevas inversiones que precisan un conocimiento del estado real del equipo para llevarla a cabo. Una de las herramientas

  1. Assessment and comparison of 100-MW coal gasification phosphoric acid fuel cell power plants

    Science.gov (United States)

    Lu, Cheng-Yi

    1988-01-01

    One of the advantages of fuel cell (FC) power plants is fuel versatility. With changes only in the fuel processor, the power plant will be able to accept a variety of fuels. This study was performed to design process diagrams, evaluate performance, and to estimate cost of 100 MW coal gasifier (CG)/phosphoric acid fuel cell (PAFC) power plant systems utilizing coal, which is the largest single potential source of alternate hydrocarbon liquids and gases in the United States, as the fuel. Results of this study will identify the most promising integrated CG/PAFC design and its near-optimal operating conditions. The comparison is based on the performance and cost of electricity which is calculated under consistent financial assumptions.

  2. Coagulation effects of persistent organic pollutant PFOA in water by PAFC%PAFC对水体中持久性有机污染物PFOA的混凝效果

    Institute of Scientific and Technical Information of China (English)

    赵莉; 杨柳; 常青; 李宗硕; 刘鹏宇; 高彩丽

    2013-01-01

    针对含全氟辛酸(PFOA)的工业废水及应对PFOA的污染突发事件,采用PAFC及其复配粘土矿物凹凸棒和沸石进行混凝实验,并对几个影响因素进行了考察.结果表明,在PAFC的最佳投加量10 mg/L时,PFOA和浊度的去除率分别达到70.25%和99.42%,PAFC混凝处理PFOA的效果优于PAC;pH值对PAFC去除PFOA有一定的影响,当pH大于6时有利于PFOA的去除;PFOA和浊度的去除率随原始浊度的增加而增加;活性炭、盐酸改性凹凸棒、盐酸改性沸石、CT-MAB改性的沸石复配PAFC均可提高PFOA的去除率;改性处理后的沸石应用于PFOA的处理中,有望降低处理成本.%Perfluorooctanoate (PFOA) as one of emerging contaminants,has been attracting increasing concerns in recent years.Model solution was treated using primary flocculant polyaluminum ferric chloride (PAFC) and coagulant aid attapulgite or zeolite were conducted in this work.The experimental results showed that the removal rate of PFOA and turbidity reached 70.25% and 99.42%,respectively at the optimal PAFC dosage of 10 mg/L,and the removal effect of PFOA by PAFC was better than PAC.The removal rate of PFOA is significantly affected by the pH value of solution,and the maximum removal of PFOA is obtained at the near neutral solution pH value.The removal rate of PFOA and turbidity increases with the increasing in initial turbidity.The removal rate of PFOA is enhanced by PAFC combined with some coagulant aid,such as activited carbon,hydrochloric acid modified attapulgite and zeolite,CTMAB modified zeolite.Using PAFC and the modified zeolite maybe is an efficient and feasible method to remove PFOA from water.

  3. Efficient on-site construction

    DEFF Research Database (Denmark)

    Thuesen, Christian Langhoff; Hvam, Lars

    2011-01-01

    Purpose – This research aims to analyse the implementation of a German platform for housing projects through a successful case on modern methods of construction featuring efficient on-site construction. Through continuous development, the platform has been carefully designed to suit a carefully s...

  4. Training Artisans On-Site

    Directory of Open Access Journals (Sweden)

    Edoghogho Ogbeifun

    2011-09-01

    Full Text Available The decline in apprenticeship in both the public and private sectors, the increasing use of sub-contractors as well as the uncoordinated approach in the informal sector are contributing factors to the shortage of skilled artisans in the construction industry. Artisans training can be introduced and implemented through the adoption of progressive implementation of construction processes commencing work from areas requiring low skill demands to areas of high skill demand. The success of this principle hinges on the collaborative effort of the key project stakeholders. The client should be willing to absorb extra cost and delays in the project; the design and contract documentation should facilitate on-site training, and  the consultant actively guide the contractor and the construction processes to achieve the training objectives. The exploratory research method was adopted in this study and research revealed that this principle was used in a project in the UK and in the development of infrastructure in the tourism industry of South Africa .It is being recommended that the principle be adapted by the public sector for the development of small size infrastructures that can be repeated in many places. This will boost the quality and quantity of artisans, enhance employability, reduce rural urban migration and alleviate poverty.Keywords: Skilled artisans, on-site training, progressive construction processes, project stakeholders, contract documentation. 

  5. 硅锰炉短网无功就地补偿装置设计%On-site Reactive Power Compensator Design for Silicon-Manganese Furnace Short Net

    Institute of Scientific and Technical Information of China (English)

    王发智

    2012-01-01

    Taking DSP2812 as master chip for reactive power compensation, the method of employing thyristor controlled reactor and fixed capacitor in reactive power compensation to improve load imbalance was taken. The application proves high compensation precision of this method in promoting the power factor.%以DSP2812作为无功补偿的主控芯片,采用晶闸管可控电抗器+固定电容器方式进行无功补偿,改善硅锰炉短网负荷不平衡的状况,该补偿方法补偿精度高,可有效地提高功率因数.

  6. The transfer function method for the evaluation of short-circuit tests and on-site diagnostics of power transformers; Die Uebertragungsfunktion als Methode zur Beurteilung der Stosskurzschlusspruefung und Vor-Ort-Isolationsdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.; Feser, K. [Stuttgart Univ. (Germany). Inst. fuer Energieuebertragung und Hochspannungstechnik; Leibfried, T. [Siemens AG, Nuernberg (Germany). Geschaeftsgebiet Leistungstransformatoren; Jaeggi, F. [Aare-Tessin AG fuer Elektrizitaet, Olten (Switzerland)

    1999-03-22

    A short circuit test according to IEC 76-5 was performed on a 125 MVA, 245 kV/53 kV power transformer from the Siemens factory in Nuremberg at the Kema high power laboratory (Arnhem, Netherlands) in March 1997. Thereby, the transfer function method was examined as an additional method for evaluating the short-circuit test. The visual inspection of the transformer after returning to the Nuremberg factory carried out by engineers from Atel and Siemens and representatives of Kema showed no changes of the core and coil assembly. At the Flumenthal substation a second transformer of the same type was installed. Before commissioning, the transfer functions of both transformers have been measured. These measurements provide essential information concerning the comparability of measurements from different transformers and are the basis for measurements to be carried out in the future. (orig.) [Deutsch] Im Maerz 1997 wurde ein 125-MVA-Leistungstranformator aus dem Siemens Transformatorenwerk Nuernberg im Hochleistungslabor der Kema, Arnheim einer Stosskurzschlusspruefung unterzogen. Dabei wurde die Analyse der Uebertragungsfunktion des Transformators als zusaetzliche Methode zur Beurteilung der Stosskurzschlusspruefung untersucht. Der Aktivteil wurde danach im Herstellerwerk begutachtet. Dabei ergaben sich keine Beanstandungen. Im Umspannwerk Flumenthal wurde ein zweiter baugleicher Transformator installiert. Vor der Inbetriebnahme wurden zusaetzliche Vergleichsmessungen an den zwei baugleichen Transformatoren durchgefuehrt. (orig.)

  7. Fuel cell programs in the United States for stationary power applications

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M.

    1996-04-01

    The Department of Energy (DOE), Office of Fossil Energy, is participating with the private sector in sponsoring the development of molten carbonate fuel cell (MCFC) and solid oxide fuel cell (SOFC) technologies for application in the utility, commercial and industrial sectors. Phosphoric acid fuel cell (PAFC) development was sponsored by the Office of Fossil Energy in previous years and is now being commercialized by the private sector. Private sector participants with the Department of Energy include the Electric Power Research Institute (EPRI), the Gas Research institute (GRI), electric and gas utilities, universities, manufacturing companies and their suppliers. through continued government and private sector support, fuel cell systems are emerging power generation technologies which are expected to have significant worldwide impacts. An industry with annual sales of over a billion dollars is envisioned early in the 21st century. PAFC power plants have begun to enter the marketplace and MCFC and SOFC power plants are expected to be ready to enter the marketplace in the late 1990s. In support of the efficient and effective use of our natural resources, the fuel cell program seeks to increase energy efficiency and economic effectiveness of power generation. This is to be accomplished through effectiveness of power generation. This is accomplished through the development and commercialization of cost-effective, efficient and environmentally desirable fuel cell systems which will operate on fossil fuels in multiple and end use sectors.

  8. Manual of phosphoric acid fuel cell power plant optimization model and computer program

    Science.gov (United States)

    Lu, C. Y.; Alkasab, K. A.

    1984-01-01

    An optimized cost and performance model for a phosphoric acid fuel cell power plant system was derived and developed into a modular FORTRAN computer code. Cost, energy, mass, and electrochemical analyses were combined to develop a mathematical model for optimizing the steam to methane ratio in the reformer, hydrogen utilization in the PAFC plates per stack. The nonlinear programming code, COMPUTE, was used to solve this model, in which the method of mixed penalty function combined with Hooke and Jeeves pattern search was chosen to evaluate this specific optimization problem.

  9. The feasibility of mobile computing for on-site inspection.

    Energy Technology Data Exchange (ETDEWEB)

    Horak, Karl Emanuel; DeLand, Sharon Marie; Blair, Dianna Sue

    2014-09-01

    With over 5 billion cellphones in a world of 7 billion inhabitants, mobile phones are the most quickly adopted consumer technology in the history of the world. Miniaturized, power-efficient sensors, especially video-capable cameras, are becoming extremely widespread, especially when one factors in wearable technology like Apples Pebble, GoPro video systems, Google Glass, and lifeloggers. Tablet computers are becoming more common, lighter weight, and power-efficient. In this report the authors explore recent developments in mobile computing and their potential application to on-site inspection for arms control verification and treaty compliance determination. We examine how such technology can effectively be applied to current and potential future inspection regimes. Use cases are given for both host-escort and inspection teams. The results of field trials and their implications for on-site inspections are discussed.

  10. Power

    DEFF Research Database (Denmark)

    Elmholdt, Claus Westergård; Fogsgaard, Morten

    2016-01-01

    In this chapter, we will explore the dynamics of power in processes of creativity, and show its paradoxical nature as both a bridge and a barrier to creativity in organisations. Recent social psychological experimental research (Slighte, de Dreu & Nijstad, 2011) on the relation between power...... and creativity suggests that when managers give people the opportunity to gain power and explicate that there is reason to be more creative, people will show a boost in creative behaviour. Moreover, this process works best in unstable power hierarchies, which implies that power is treated as a negotiable...... and floating source for empowering people in the organisation. We will explore and discuss here the potentials, challenges and pitfalls of power in relation to creativity in the life of organisations today. The aim is to demonstrate that power struggles may be utilised as constructive sources of creativity...

  11. On-Site Renewable Energy Generation

    Science.gov (United States)

    This guide describes a variety of approaches that local governments can use to advance climate and energy goals by meeting some or all of their electricity needs through on-site renewable energy generation.

  12. On-site wastewater technologies in Australia.

    Science.gov (United States)

    Ho, G; Dallas, S; Anda, M; Mathew, K

    2001-01-01

    Domestic wastewater reuse is currently not permitted anywhere in Australia but is widely supported by the community, promoted by researchers, and improvised by up to 20% of householders. Its widespread implementation will make an enormous contribution to the sustainability of water resources. Integrated with other strategies in the outdoor living environment of settlements in arid lands, great benefit will be derived. This paper describes six options for wastewater reuse under research by the Remote Area Developments Group (RADG) at Murdoch University and case studies are given where productive use is being made for revegetation and food production strategies at household and community scales. Pollution control techniques, public health precautions and maintenance requirements are described. The special case of remote Aboriginal communities is explained where prototype systems have been installed by RADG to generate windbreaks and orchards. New Australian design standards and draft guidelines for domestic greywater reuse produced by the Western Australian State government agencies for mainstream communities are evaluated. It is recommended that dry composting toilets be coupled with domestic greywater reuse and the various types available in Australia are described. For situations where only the flushing toilet will suffice the unique 'wet composting' system can be used and this also is described. A vision for household and community-scale on-site application is presented.

  13. Localization in the Anderson model with long-range correlated hopping and on-site disorders

    Science.gov (United States)

    Lotfallahzadeh, Shiva; Anvari, Mehrnaz; Ekhtiary, Niko; Esmailpour, Ayoub; Rahimi Tabar, M. Reza

    2015-01-01

    We study the metal-insulator transition in one-dimensional Anderson binary alloy with long-range disordered hopping integrals and on-site energies using the transfer matrix method. In this model, the on-site energies and hopping integrals are distributed randomly with long-range correlations characterized by power spectrum of the type ?, with different exponents ? and ?, respectively. We determine the critical value of long-range correlation exponent of hopping integral ? in the presence of only off-diagonal disorder in which the transition from localized to extended states occurs in thermodynamic limit. When both of the on-site energies and hopping integrals are disordered, there are two parameters ? and ? that control the metal-insulator transition in the system. We draw the phase diagram which separates the localized regime from extended one and it shows the critical values of ? for a given value of ?.

  14. CLIMATE CHANGE FUEL CELL PROGRAM 200 kW - PC25C FUEL CELL POWER PLANT FOR THE ST.-AGNES-HOSPITAL, BOCHOLT, GERMANY

    Energy Technology Data Exchange (ETDEWEB)

    Dipl.-Ing. Knut Stahl

    2002-01-31

    Since the beginning of the Year 2001, the Saint-Agnes-Hospital in Bocholt, Germany, operates a phosphoric acid fuel cell (PAFC) to provide the base load of electrical power as well as heat in Winter and air conditioning in Summer. The project was made possible by federal funding from the U.S. Department of Energy as well as by a strategic alliance with the local utility company, the Bocholter Energie- und Wasserversorgung GmbH (BEW), and with the gas supplier of BEW, the Thyssengas GmbH. The fuel cell power plant is combined with an absorption chiller. It is highly efficient and has an excellent power to heat ratio. The operation during the first Year went smoothly and nearly free of trouble.

  15. 7 CFR 205.403 - On-site inspections.

    Science.gov (United States)

    2010-01-01

    ... Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) ORGANIC FOODS PRODUCTION ACT PROVISIONS NATIONAL ORGANIC PROGRAM Certification § 205.403 On-site inspections. (a) On-site inspections....

  16. On-site energy consumption at softwood sawmills in Montana

    Science.gov (United States)

    Dan Loeffler; Nathaniel Anderson; Todd A. Morgan; Colin B. Sorenson

    2016-01-01

    Total on-site energy requirements for wood product manufacturing are generally not well understood or publicly available, particularly at subregional scales, such as the state level. This article uses a mail survey of softwood sawmills in Montana to develop a profile of all on-site energy consumption. Energy use is delineated by fuel type on a production basis...

  17. Optimal selection of on-site generation with combined heat andpower applications

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, Afzal S.; Marnay, Chris; Bailey, Owen; HamachiLaCommare, Kristina

    2004-11-30

    While demand for electricity continues to grow, expansion of the traditional electricity supply system, or macrogrid, is constrained and is unlikely to keep pace with the growing thirst western economies have for electricity. Furthermore, no compelling case has been made that perpetual improvement in the overall power quality and reliability (PQR)delivered is technically possible or economically desirable. An alternative path to providing high PQR for sensitive loads would generate close to them in microgrids, such as the Consortium for Electricity Reliability Technology Solutions (CERTS) Microgrid. Distributed generation would alleviate the pressure for endless improvement in macrogrid PQR and might allow the establishment of a sounder economically based level of universal grid service. Energy conversion from available fuels to electricity close to loads can also provide combined heat and power (CHP) opportunities that can significantly improve the economics of small-scale on-site power generation, especially in hot climates when the waste heat serves absorption cycle cooling equipment that displaces expensive on-peak electricity. An optimization model, the Distributed Energy Resources Customer Adoption Model (DER-CAM), developed at Berkeley Lab identifies the energy bill minimizing combination of on-site generation and heat recovery equipment for sites, given their electricity and heat requirements, the tariffs they face, and a menu of available equipment. DER-CAM is used to conduct a systemic energy analysis of a southern California naval base building and demonstrates atypical current economic on-site power opportunity. Results achieve cost reductions of about 15 percent with DER, depending on the tariff.Furthermore, almost all of the energy is provided on-site, indicating that modest cost savings can be achieved when the microgrid is free to select distributed generation and heat recovery equipment in order to minimize its over all costs.

  18. International Symposium on Site Characterization for CO2Geological Storage

    Energy Technology Data Exchange (ETDEWEB)

    Tsang, Chin-Fu

    2006-02-23

    Several technological options have been proposed to stabilize atmospheric concentrations of CO{sub 2}. One proposed remedy is to separate and capture CO{sub 2} from fossil-fuel power plants and other stationary industrial sources and to inject the CO{sub 2} into deep subsurface formations for long-term storage and sequestration. Characterization of geologic formations for sequestration of large quantities of CO{sub 2} needs to be carefully considered to ensure that sites are suitable for long-term storage and that there will be no adverse impacts to human health or the environment. The Intergovernmental Panel on Climate Change (IPCC) Special Report on Carbon Dioxide Capture and Storage (Final Draft, October 2005) states that ''Site characterization, selection and performance prediction are crucial for successful geological storage. Before selecting a site, the geological setting must be characterized to determine if the overlying cap rock will provide an effective seal, if there is a sufficiently voluminous and permeable storage formation, and whether any abandoned or active wells will compromise the integrity of the seal. Moreover, the availability of good site characterization data is critical for the reliability of models''. This International Symposium on Site Characterization for CO{sub 2} Geological Storage (CO2SC) addresses the particular issue of site characterization and site selection related to the geologic storage of carbon dioxide. Presentations and discussions cover the various aspects associated with characterization and selection of potential CO{sub 2} storage sites, with emphasis on advances in process understanding, development of measurement methods, identification of key site features and parameters, site characterization strategies, and case studies.

  19. On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System Development

    Energy Technology Data Exchange (ETDEWEB)

    Caffrey, Gus J. [Idaho National Laboratory, Idaho Falls, ID (United States); Egger, Ann E. [Idaho National Laboratory, Idaho Falls, ID (United States); Krebs, Kenneth M. [Idaho National Laboratory, Idaho Falls, ID (United States); Milbrath, B. D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jordan, D. V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Warren, G. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wilmer, N. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-01

    We have designed and tested hardware and software for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—Osiris—software filters the spectral data to display only radioisotopic information relevant to CTBT on-site inspections, e.g.,132I. A set of over 100 fission-product spectra was employed for Osiris testing. These spectra were measured, where possible, or generated by modeling. The synthetic test spectral compositions include non-nuclear-explosion scenarios, e.g., a severe nuclear reactor accident, and nuclear-explosion scenarios such as a vented underground nuclear test. Comparing its computer-based analyses to expert visual analyses of the test spectra, Osiris correctly identifies CTBT-relevant fission product isotopes at the 95% level or better.The Osiris gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC Transpec-100, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer was used successfully during the recent 2014 CTBT Integrated Field Exercise in Jordan. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. To date, software development has been the main focus of the Osiris project. In FY2016-17, we plan to modify the Osiris hardware, integrate the Osiris software and hardware, and conduct rigorous field tests to ensure that the Osiris system will function correctly during CTBT on-site inspections. The planned development will raise Osiris to technology readiness level TRL-8; transfer the Osiris technology to a commercial manufacturer, and demonstrate Osiris to potential CTBT on-site inspectors.

  20. Corporate travel medicine: benefit analysis of on-site services.

    Science.gov (United States)

    Prince, T S; Spengler, S E; Collins, T R

    2001-01-01

    Corporations with employees who travel internationally address their travel-related medical needs in a variety of ways. Options utilized include corporate medical departments, local health departments, and local clinics, both contracted and independent. A travel clinic at a university medical center routinely provided preventive travel medicine services for many of the local companies. Two of these companies had on-site medical clinics which routinely saw patients for occupational and personal health reasons. At these companies , the university travel clinic assisted in moving employee travel medicine services to the on-site clinic. Direct and indirect costs for new, predeparture employee travel care at each company were compared before, and after, the move on-site. When measured per patient, total cost savings associated with the on-site travel clinic were greater than 15% at both companies (17%, 25%), primarily due to the value of the employees' time saved with decreased travel. Utilization increased at one company by 24% over the first 8 months and lead to higher overall cost, but this cost increase was only 4%. Informal assessments of the value of the on-site service at both companies was uniformly positive. For certain corporate settings, on-site clinics may be effective ways of providing travel medicine services.

  1. On-Site Renewable Energy and Green Buildings: A System-Level Analysis.

    Science.gov (United States)

    Al-Ghamdi, Sami G; Bilec, Melissa M

    2016-05-03

    Adopting a green building rating system (GBRSs) that strongly considers use of renewable energy can have important environmental consequences, particularly in developing countries. In this paper, we studied on-site renewable energy and GBRSs at the system level to explore potential benefits and challenges. While we have focused on GBRSs, the findings can offer additional insight for renewable incentives across sectors. An energy model was built for 25 sites to compute the potential solar and wind power production on-site and available within the building footprint and regional climate. A life-cycle approach and cost analysis were then completed to analyze the environmental and economic impacts. Environmental impacts of renewable energy varied dramatically between sites, in some cases, the environmental benefits were limited despite the significant economic burden of those renewable systems on-site and vice versa. Our recommendation for GBRSs, and broader policies and regulations, is to require buildings with higher environmental impacts to achieve higher levels of energy performance and on-site renewable energy utilization, instead of fixed percentages.

  2. Issues in fuel cell commercialization

    Science.gov (United States)

    Appleby, A. J.

    After 25 years of effort, the phosphoric acid fuel cell (PAFC) is approaching commercialization as cell stack assemblies (CAS) show convincingly low degradation and its balance-of-plant (BOP) achieves mature reliability. A high present capital cost resulting from limited cumulative production remains an issue. The primary PAFC developer in the USA (International Fuel Cells, IFC) has only manufactured 40 MW of PAFC components to date, the equivalent of a single large gas turbine aero-engine or 500 compact car engines. The system is therefore still far up the production learning curve. Even so, the next generation of on-site 40% electrical efficiency (LHV) combined heat-and-power (CHP) PAFC system was available for order from IFC in 1995 at US 3000/kW (1995). To effectively compete in the marketplace with diesel generators, the dispersed cogeneration PAFC must cost approximately US 1550/kW (1995) in the USA and Europe. At somewhat lower costs than this, dispersed cogeneration PAFCs will compete with large combined-cycle generators. However, in Japan, costs greater than US 2000/kW will be competitive, based on the late-1995 trade exchange rate of 100-105 Yen/US ). The perceived advantages of fuel cell technologies over developments of more conventional generators (e.g., ultra-low emissions, siting) are not strong selling points in the marketplace. The ultimate criterion is cost. Cost reduction is now the key to market penetration. This must include reduced installation costs, for which the present goal is US$ 385/kW (1995). How further capital cost reductions can be achieved by the year 2000 is discussed. Progress to date is reviewed, and the potential for pressurized electric utility PAFC units is determined. Markets for high-temperature fuel cell system (molten carbonate, MCFC, and solid oxide, SOFC), which many consider to be 20 and 30 years, respectively, behind the PAFC, are discussed. Their high efficiency and high-quality waste heat should make them attractive

  3. Analysis of a fuel cell on-site integrated energy system for a residential complex

    Science.gov (United States)

    Simons, S. N.; Maag, W. L.

    1979-01-01

    The energy use and costs of the on-site integrated energy system (OS/IES) which provides electric power from an on-site power plant and recovers heat that would normally be rejected to the environment is compared to a conventional system purchasing electricity from a utility and a phosphoric acid fuel cell powered system. The analysis showed that for a 500-unit apartment complex a fuel OS/IES would be about 10% more energy conservative in terms of total coal consumption than a diesel OS/IES system or a conventional system. The fuel cell OS/IES capital costs could be 30 to 55% greater than the diesel OS/IES capital costs for the same life cycle costs. The life cycle cost of a fuel cell OS/IES would be lower than that for a conventional system as long as the cost of electricity is greater than $0.05 to $0.065/kWh. An analysis of several parametric combinations of fuel cell power plant and state-of-art energy recovery systems and annual fuel requirement calculations for four locations were made. It was shown that OS/IES component choices are a major factor in fuel consumption, with the least efficient system using 25% more fuel than the most efficient. Central air conditioning and heat pumps result in minimum fuel consumption while individual air conditioning units increase it, and in general the fuel cell of highest electrical efficiency has the lowest fuel consumption.

  4. On-site storage of high level nuclear waste: attitudes and perceptions of local residents.

    Science.gov (United States)

    Bassett, G W; Jenkins-Smith, H C; Silva, C

    1996-06-01

    No public policy issue has been as difficult as high-level nuclear waste. Debates continue regarding Yucca Mountain as a disposal site, and-more generally-the appropriateness of geologic disposal and the need to act quickly. Previous research has focused on possible social, political, and economic consequences of a facility in Nevada. Impacts have been predicted to be potentially large and to emanate mainly from stigmatization of the region due to increased perceptions of risk. Analogous impacts from leaving waste at power plants have been either ignored or assumed to be negligible. This paper presents survey results on attitudes of residents in three counties where nuclear waste is currently stored. Topics include perceived risk, knowledge of nuclear waste and radiation, and impacts on jobs, tourism, and housing values from leaving waste on site. Results are similar to what has been reported for Nevada; the public is concerned about possible adverse effects from on-site storage of waste.

  5. Information model for on-site inspection system

    Energy Technology Data Exchange (ETDEWEB)

    Bray, O.H.; Deland, S.

    1997-01-01

    This report describes the information model that was jointly developed as part of two FY93 LDRDs: (1) Information Integration for Data Fusion, and (2) Interactive On-Site Inspection System: An Information System to Support Arms Control Inspections. This report describes the purpose and scope of the two LDRD projects and reviews the prototype development approach, including the use of a GIS. Section 2 describes the information modeling methodology. Section 3 provides a conceptual data dictionary for the OSIS (On-Site Information System) model, which can be used in conjunction with the detailed information model provided in the Appendix. Section 4 discussions the lessons learned from the modeling and the prototype. Section 5 identifies the next steps--two alternate paths for future development. The long-term purpose of the On-Site Inspection LDRD was to show the benefits of an information system to support a wide range of on-site inspection activities for both offensive and defensive inspections. The database structure and the information system would support inspection activities under nuclear, chemical, biological, and conventional arms control treaties. This would allow a common database to be shared for all types of inspections, providing much greater cross-treaty synergy.

  6. On-site early-warning system for Bishkek (Kyrgyzstan

    Directory of Open Access Journals (Sweden)

    Dino Bindi

    2015-04-01

    Full Text Available In this work, the development of an on-site early warning system for Bishkek (Kyrgyzstan is outlined. Several low cost sensors equipped with MEMS accelerometers are installed in eight buildings distributed within the urban area. The different sensing units communicate each other via wireless links and the seismic data are streamed in real-time to the data center using internet. Since each single sensing unit has computing capabilities, software for data processing can be installed to perform decentralized actions. In particular, each sensing unit can perform event detection task and run software for on-site early warning. If a description for the vulnerability of the building is uploaded in the sensing unit, this piece of information can be exploited to introduce the expected probability of damage in the early-warning protocol customized for a specific structure.

  7. Continuous feed, on-site composting of kitchen garbage.

    Science.gov (United States)

    Hwang, Eung-Ju; Shin, Hang-Sik; Tay, Joo-Hwa

    2002-04-01

    Kitchen garbage generated at a school cafeteria was treated and stabilised in a controlled on-site composting unit for volume reduction and on-site utilisation of processed garbage. The on-site composter was fed with the garbage on a daily basis during the two-months experimental period. Compost was not removed from the unit but was entirely reused as a bulking agent in order to minimise the need for additional bulking agent and compost handling. Performance of the composter tinder this condition was investigated. Most of the easily degradable organic matter (EDM) in the garbage was biodegraded rapidly, and the final product had a low content of EDM. Lipids, total sugar, and hemi-cellulose were degraded 96%, 81%, and 66% respectively. Free air space (FAS) was higher than 0.5 all the time, so accumulation of dry matter in the unit was not significant in reducing reaction efficiency. Other reaction parameters such as pH and MC were kept within a suitable range; however, it was advisable to maintain MC at over 46%. As a result, this method of operation was able to stabilise the garbage with low sawdust demand and little compost production.

  8. Micro-grid for on-site wind-and-hydrogen powered generation

    Directory of Open Access Journals (Sweden)

    Suskis P.

    2014-02-01

    Full Text Available Rakstā piedāvātā mikrotīkla izpēte ir veikta ar mērķi izstrādāt autonomu, uz vēja un ūdeņraža enerģiju balstītu elektroapgādes sistēmu, kas varētu aizvietot tradicionālās fosilā kurināmā sistēmas, piemēram, mājsaimniecību dīzeļa ģeneratorus, gāzes mikroturbīnas u.c. Mikrotīkla elektroapgādes sistēmā vēja agregāta saražotā elektroenerģija tiek pārveidota atbilstoši standarta maiņsprieguma elektroapgādes parametriem un piegādāta slodzei. Pārpalikusī enerģija tiek pārveidota un uzkrāta ūdeņraža formā, izmantojot elektrolīzes iekārtu un kompozītmateriālu uzkrājēju. Ja pieejamā vēja enerģija nenosedz slodzes enerģijas patēriņu, elektroenerģijas padeves funkciju ar atbilstoša energoelektronikas pārveidotāja palīdzību pārņem ūdeņraža degvielas elements. Ja, savukārt, slodzei nav nepieciešama enerģija, no vēja saražoto enerģiju izmanto elektrolīzes iekārta un tā tiek uzkrāta ūdeņraža formā, atbilstoši uzkrājēja ietilpībai. Piedāvātajā mikrotīklā ir izmantota elektrolīzes iekārta ar netradicionāliem elektrodu pārklājumiem un barošanas bloku, kā arī zemspiediena kompozītmateriālu ūdeņraža uzkrājējs. Galvenie mikrotīkla elektriskās enerģijas pārveidošanas mezgli ir realizēti uz energoefektīvu energoelektronikas pārveidotāju bāzes. Ir izveidoti atsevišķo piedāvātās elektroapgādes sistēmas iekārtu prototipi un veiktas to eksperimantālās pārbaudes, gan atsevišķi, gan darbam kopējā sistēmā.

  9. Portable Infrared Laser Spectroscopy for On-site Mycotoxin Analysis

    Science.gov (United States)

    Sieger, Markus; Kos, Gregor; Sulyok, Michael; Godejohann, Matthias; Krska, Rudolf; Mizaikoff, Boris

    2017-03-01

    Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B1 affected peanuts at EU regulatory limits of 1250 μg kg‑1 and 8 μg kg‑1, respectively.

  10. Portable Infrared Laser Spectroscopy for On-site Mycotoxin Analysis

    Science.gov (United States)

    Sieger, Markus; Kos, Gregor; Sulyok, Michael; Godejohann, Matthias; Krska, Rudolf; Mizaikoff, Boris

    2017-01-01

    Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B1 affected peanuts at EU regulatory limits of 1250 μg kg−1 and 8 μg kg−1, respectively. PMID:28276454

  11. The On-Site Analysis of the Cherenkov Telescope Array

    CERN Document Server

    Bulgarelli, Andrea; Zoli, Andrea; Aboudan, Alessio; Rodríguez-Vázquez, Juan José; De Cesare, Giovanni; De Rosa, Adriano; Maier, Gernot; Lyard, Etienne; Bastieri, Denis; Lombardi, Saverio; Tosti, Gino; Bergamaschi, Sonia; Beneventano, Domenico; Lamanna, Giovanni; Jacquemier, Jean; Kosack, Karl; Antonelli, Lucio Angelo; Boisson, Catherine; Borkowski, Jerzy; Buson, Sara; Carosi, Alessandro; Conforti, Vito; Colomé, Pep; Reyes, Raquel de los; Dumm, Jon; Evans, Phil; Fortson, Lucy; Fuessling, Matthias; Gotz, Diego; Graciani, Ricardo; Gianotti, Fulvio; Grandi, Paola; Hinton, Jim; Humensky, Brian; Inoue, Susumu; Knödlseder, Jürgen; Flour, Thierry Le; Lindemann, Rico; Malaguti, Giuseppe; Markoff, Sera; Marisaldi, Martino; Neyroud, Nadine; Nicastro, Luciano; Ohm, Stefan; Osborne, Julian; Oya, Igor; Rodriguez, Jerome; Rosen, Simon; Ribo, Marc; Tacchini, Alessandro; Schüssler, Fabian; Stolarczyk, Thierry; Torresi, Eleonora; Testa, Vincenzo; Wegner, Peter

    2015-01-01

    The Cherenkov Telescope Array (CTA) observatory will be one of the largest ground-based very high-energy gamma-ray observatories. The On-Site Analysis will be the first CTA scientific analysis of data acquired from the array of telescopes, in both northern and southern sites. The On-Site Analysis will have two pipelines: the Level-A pipeline (also known as Real-Time Analysis, RTA) and the level-B one. The RTA performs data quality monitoring and must be able to issue automated alerts on variable and transient astrophysical sources within 30 seconds from the last acquired Cherenkov event that contributes to the alert, with a sensitivity not worse than the one achieved by the final pipeline by more than a factor of 3. The Level-B Analysis has a better sensitivity (not be worse than the final one by a factor of 2) and the results should be available within 10 hours from the acquisition of the data: for this reason this analysis could be performed at the end of an observation or next morning. The latency (in part...

  12. Use of leaching chambers for on-site sewage treatment.

    Science.gov (United States)

    St Marseille, J G; Anderson, B C

    2002-03-01

    An innovative chamber system was installed for on-site sewage treatment beneath an active parking lot at a restaurant near Cornwall, Ontario. The configuration of this prototype system used polyethylene leaching chambers over which wastewater was allowed to trickle. The chambers were vented to the surface to provide direct, passive air transfer. This demonstration project was examined as a cost-effective wastewater treatment alternative for a very constrained site. The leaching chambers were installed over a geotextile-covered sand filter bed. Chamber sidewall contact contributed an additional 50% to the total soil contact area hence justification for a footprint reduction. A labile carbon source (sawdust) was added into one half of the bed to encourage dissimilatory denitrification. Average hydraulic loading was 50 l m(-1) day(-1) (5 cm day(-1)). Treatment rates exceeded more than 4 orders of magnitude removal for E. coli; 90% biochemical oxygen demand; ammonium; and 99% total phosphorus. Nitrate-N on the carbon-amended side averaged 0.6 mg l(-1) compared with 8.6 mg l(-1) on the (non-carbon) control side. This project has demonstrated that effective on-site treatment can be accomplished. Flow and load equalization, pulse dosing, chamber venting, phosphorus precipitation, and denitrification were keys to treatment success. Applications include domestic and commercial sites.

  13. Role of on-site microscopic evaluation of kidney biopsy for adequacy and allocation of glomeruli: comparison of renal biopsies with and without on-site microscopic evaluation.

    Science.gov (United States)

    Gilani, S M; Ockner, D; Qu, H

    2013-12-01

    Evaluation of kidney core biopsies ideally begins with on-site microscopic examination for adequacy and allocation of tissue for light microscopy (LM), immunofluorescence (IF) and electron microscopy (EM). However, some renal biopsies are not microscopically evaluated by a pathologist at the time of procedure, and are allocated without on-site evaluation. This study compares the actual outcome of these two techniques. We reviewed the reports of patients who underwent kidney biopsy for medical causes in the past two years. Eighty-eight biopsies had on-site microscopic evaluation by pathologists, and 70 biopsies did not undergo on-site evaluation. For biopsies without on-site evaluation, no glomeruli were seen in 5 (7.14%) cases for LM, 11 (15.71%) cases for IF and 6 (8.57%) cases for EM. In cases with on-site evaluation, the absence of glomeruli was identified in 1 (1.13%) case for LM, 3 (3.4%) for IF and 3 (3.4%) for EM. The biopsies with on-site microscopic evaluation had 5.68% of the cases considered as inadequate, while 22% of biopsies without on-site evaluation were considered inadequate. The biopsies with on-site evaluation tended to have more glomeruli obtained during the procedure (p < 0.0005). Without on-site evaluation, the likelihood of getting an inadequate specimen compared to on-site evaluation is nearly four times greater.

  14. A business case for on-site generation: The BD biosciences pharmingen project

    Energy Technology Data Exchange (ETDEWEB)

    Firestone, Ryan; Creighton, Charles; Bailey, Owen; Marnay, Chris; Stadler, Michael

    2003-09-01

    Deregulation is haltingly changing the United States electricity markets. The resulting uncertainty and/or rising energy costs can be hedged by generating electricity on-site and other benefits, such as use of otherwise wasted heat, can be captured. The Public Utility Regulatory Policy Act (PURPA) of 1978 first invited relatively small-scale generators ({ge} 1 MW) into the electricity market. The advent of efficient and reliable small scale and renewable equipment has spurred an industry that has, in recent years, made even smaller (business scale) electricity generation an economically viable option for some consumers. On-site energy capture and/or conversion, known as distributed energy resources (DER), offers consumers many benefits, such as economic savings and price predictability, improved reliability, control over power quality, and emissions reductions. Despite these benefits, DER adoption can be a daunting move to a customer accustomed to simply paying a monthly utility bill. San Diego is in many ways an attractive location for DER development: It has high electricity prices typical of California and a moderate climate i.e. energy loads are consistent throughout the year. Additionally, the price shock to San Diego Gas and Electric (SDG&E) customers during the summer of 2000 has interested many in alternatives to electricity price vulnerability. This report examines the business case for DER at the San Diego biotechnology supply company, BD Biosciences Pharmingen, which considered DER for a building with 200-300 kW base-load, much of which accommodates the refrigerators required to maintain chemicals. Because of the Mediterranean climate of the San Diego area and the high rate of air changes required due to on-site use of chemicals, modest space heating is required throughout the year. Employees work in the building during normal weekday business hours, and daily peak loads are typically about 500 kW.

  15. Analysis of acoustic-seismic coupling for CTBT on-site inspection support

    Energy Technology Data Exchange (ETDEWEB)

    Liebsch, Mattes [Experimentelle Physik III, TU Dortmund (Germany)

    2014-07-01

    The measurements of weak seismic signals, e.g. aftershock measurements during an on-site inspection for the Comprehensive Nuclear Test-Ban Treaty (CTBT), can be masked by man-made disturbances. These can be caused by airborne signals, like the noises of aircraft or helicopters, which couple to the ground and excite soil vibrations. We have measured sound pressure and corresponding soil vibrations caused by aircraft and by signals produced artificially with a speaker. Methods of acoustic deadening were applied to reduce the incident acoustic power locally. The influence on soil vibrations in different depths below the surface is investigated. The underlying question was whether the coupling of sound happens locally or soil vibrations created in a wide area around the sensor sum up to the total seismic signal. A better understanding of acoustic-seismic coupling can be used to develop guidelines for seismic aftershock measurements in order to improve the performance of on-site inspections for the CTBT.

  16. Loch Linnhe `94: Test operations description and on-site analysis, US activities

    Energy Technology Data Exchange (ETDEWEB)

    Mantrom, D.D.

    1994-11-01

    A field experiment named Loch Linnhe `94 (LL94) is described. This experiment was conducted in upper Loch Linnhe, Scotland, in September 1994, as an exercise involving UK and US investigators, under the Joint UK/US Radar Ocean Imaging Program. This experiment involved a dual-frequency, dual-polarization hillside real aperture radar operated by the UK, Lawrence Livermore National Laboratory`s (LLNL) current meter array (CMA), in-water hydrodynamic sensors, and meteorological measurements. The primary measurements involved imaging ship-generated and ambient internal waves by the radar and the CMA. This report documents test operations from a US perspective and presents on-site analysis results derived by US investigators. The rationale underlying complementary radar and CMA measurements is described. Descriptions of the test site, platforms, and major US instrument systems are given. A summary of test operations and examples of radar, CMA, water column profile, and meteorological data are provided. A description of the rather extensive analysis of these data performed at the LL94 test site is presented. The products of this analysis are presented and some implications for further analysis and future experiments are discussed. All experimental objectives were either fully or partially met. Powerful on-site analysis capabilities generated many useful products and helped improve subsequent data collection. Significant further data analysis is planned.

  17. Assessment of the environmental aspects of the DOE phosphoric acid fuel cell program

    Science.gov (United States)

    Lundblad, H. L.; Cavagrotti, R. R.

    1983-01-01

    The likely facets of a nationwide phosphoric acid fuel cell (PAFC) power plant commercial system are described. The beneficial and adverse environmental impacts produced by the system are assessed. Eleven specific system activities are characterized and evaluated. Also included is a review of fuel cell technology and a description of DOE's National Fuel Cell Program. Based on current and reasonably foreseeable PAFC characteristics, no environmental or energy impact factor was identified that would significantly inhibit the commercialization of PAFC power plant technology.

  18. Greenhouse gas emissions from on-site wastewater treatment systems

    Science.gov (United States)

    Somlai-Haase, Celia; Knappe, Jan; Gill, Laurence

    2016-04-01

    Nearly one third of the Irish population relies on decentralized domestic wastewater treatment systems which involve the discharge of effluent into the soil via a percolation area (drain field). In such systems, wastewater from single households is initially treated on-site either by a septic tank and an additional packaged secondary treatment unit, in which the influent organic matter is converted into carbon dioxide (CO2) and methane (CH4) by microbial mediated processes. The effluent from the tanks is released into the soil for further treatment in the unsaturated zone where additional CO2 and CH4 are emitted to the atmosphere as well as nitrous oxide (N2O) from the partial denitrification of nitrate. Hence, considering the large number of on-site systems in Ireland and internationally, these are potential significant sources of greenhouse gas (GHG) emissions, and yet have received almost no direct field measurement. Here we present the first attempt to quantify and qualify the production and emissions of GHGs from a septic tank system serving a single house in the County Westmeath, Ireland. We have sampled the water for dissolved CO2, CH4 and N2O and measured the gas flux from the water surface in the septic tank. We have also carried out long-term flux measurements of CO2 from the drain field, using an automated soil gas flux system (LI-8100A, Li-Cor®) covering a whole year semi-continuously. This has enabled the CO2 emissions from the unsaturated zone to be correlated against different meteorological parameters over an annual cycle. In addition, we have integrated an ultraportable GHG analyser (UGGA, Los Gatos Research Inc.) into the automated soil gas flux system to measure CH4 flux. Further, manual sampling has also provided a better understanding of N2O emissions from the septic tank system.

  19. On site inspection for nuclear test ban verirication

    Directory of Open Access Journals (Sweden)

    P. D. Marschall

    1994-06-01

    Full Text Available The problem of verifying compliance with a nuclear test ban treaty is mainly a technical one. However the problem of detecting, locating and identifying nuclear explosions has, since the late 1950s, been intimately involved with the political problems associated with negotiating a treaty. In fact there are few other areas in which policy, diplomacy and science have been so interwoven. This paper attempts to illustrate how technology can. be applied to solve some of the political problems which arise when considering the role of an On Site Inspection (OSI to determine whether or not a nuclear explosion, in violation of a treaty, has occurred or not. It is hoped that the reader, with a scientific background, but with little or no experience of treaty negotiations, will gain an. insight as to how technical matters can interact with political requirements. The demands made on scientists to provide technical support for negotiating and rnonitoring compliance of a treaty have increased significanfly over the last 40 years. This is a period in which a number of major treaties have contained a significant technical component e.g. the Limited Test Ban Treaty (Threshold Treaty and the Chemical Weapon Convention. This paper gives an indication of some of the political decisions which will have to be made and suggests some of the technical methods which are of value in the identification of a clandestine nuclear explosion.

  20. Phytoremediation as an on-site ex situ remediation option

    Energy Technology Data Exchange (ETDEWEB)

    Millard, G. [Shell Canada Ltd., Calgary, AB (Canada); Maurice, R. [Wardrop Engineering Inc., Winnipeg, MB (Canada); Greenberg, B. [Waterloo Environmental Biotechnology Inc., Waterloo, ON (Canada)

    2008-07-01

    In-situ soil remediation techniques often have limited application or long timelines in fine-grained soils. For rapid remediation at fine-grained sites, excavation is still a common technique. However, excavation does not necessarily require landfill disposal of impacted soils. Onsite treatment of hydrocarbon-impacted soils is often a feasible approach. This presentation discussed phytoremediation as an on-site ex-situ remediation option. Phytoremediation involves the attenuation of impacts via the cultivation of suitable plants. The presentation discussed the theory of phytoremediation at hydrocarbon-impacted sites and described a case study at a former Shell-owned facility in southern Manitoba. A feasibility assessment was conducted and the results of excavation activities were outlined. Planting and maintenance activities were described. The presentation provided an update on the remediation progress, the mechanism of remediation, and the benefits of this process. The site was remediated in less than one year, with cost savings as compared to traditional soil disposal. Phytoremediation resulted in reduced greenhouse gas emissions; reduced loading of landfill; reduced impact to local roads; reduced risk to health and safety; and provided the community with an aesthetic site during remediation. tabs., figs.

  1. A potentiometric biosensor for rapid on-site disease diagnostics.

    Science.gov (United States)

    Tarasov, Alexey; Gray, Darren W; Tsai, Meng-Yen; Shields, Niall; Montrose, Armelle; Creedon, Niamh; Lovera, Pierre; O'Riordan, Alan; Mooney, Mark H; Vogel, Eric M

    2016-05-15

    Quantitative point-of-care (POC) devices are the next generation for serological disease diagnosis. Whilst pathogen serology is typically performed by centralized laboratories using Enzyme-Linked ImmunoSorbent Assay (ELISA), faster on-site diagnosis would infer improved disease management and treatment decisions. Using the model pathogen Bovine Herpes Virus-1 (BHV-1) this study employs an extended-gate field-effect transistor (FET) for direct potentiometric serological diagnosis. BHV-1 is a major viral pathogen of Bovine Respiratory Disease (BRD), the leading cause of economic loss ($2 billion annually in the US only) to the cattle and dairy industry. To demonstrate the sensor capabilities as a diagnostic tool, BHV-1 viral protein gE was expressed and immobilized on the sensor surface to serve as a capture antigen for a BHV-1-specific antibody (anti-gE), produced in cattle in response to viral infection. The gE-coated immunosensor was shown to be highly sensitive and selective to anti-gE present in commercially available anti-BHV-1 antiserum and in real serum samples from cattle with results being in excellent agreement with Surface Plasmon Resonance (SPR) and ELISA. The FET sensor is significantly faster than ELISA (disease intervention. This sensor technology is versatile, amenable to multiplexing, easily integrated to POC devices, and has the potential to impact a wide range of human and animal diseases.

  2. Benefits of On-Site Management of Environmental Restoration Wastes

    Energy Technology Data Exchange (ETDEWEB)

    Irwin, Michael J. ,P.E.; Wood, Craig, R.E.M.; Kwiecinski, Daniel, P.E.; Alanis, Saul

    2003-02-27

    As Sandia National Laboratories/New Mexico (SNL/NM) began assessing options under which to conduct the remediation of environmental restoration sites, it became clear that the standard routes for permanent disposal of waste contaminated with hazardous materials would be difficult. Publicly, local citizens' groups resisted the idea of large volumes of hazardous waste being transported through their communities. Regulations for the off-site disposal are complicated due to the nature of the environmental restoration waste, which included elevated tritium levels. Waste generated from environmental restoration at SNL/NM included debris and soils contaminated with a variety of constituents. Operationally, disposal of environmental restoration waste was difficult because of the everchanging types of waste generated during site remediation. As an alternative to standard hazardous waste disposal, SNL/NM proposed and received regulatory approval to construct a Corrective Action Management Unit (CAMU). By containing the remediation wastes on-site, SNL/NM's Environmental Restoration (ER) Program managed to eliminate transportation concerns from the public, worked with regulatory agencies to develop a safe, permanent disposal, and modified the waste disposal procedures to accommodate operational changes. SNL/NM accomplished the task and saved approximately $200 million over the life of the CAMU project, as compared to off-site disposal options.

  3. On-site digital heritage inventory development at Bat, Oman

    Science.gov (United States)

    Kondo, Y.; Miki, T.; Kuronuma, T.; Oguchi, T.

    2015-08-01

    This paper reports on the on-site development of a local-scale digital heritage inventory (DHI) of the Bronze Age site at Bat in the interior of Oman. The goal of this inventory project was to share geospatial and archaeological information of tombs and other built structures with researchers and government agents to conduct cultural heritage management, scientific research, outreach, and education. To this end, the Bat Digital Heritage Inventory (BatDHI) was compiled at the local office by incorporating previous survey records, which were concurrently crosschecked and updated by ground-truth surveys. The current version of the BatDHI was implemented using a combination of a network-access-ready database application, open source geographical information system, and web-based map engine. This system assisted both fieldwork and management works including decision making and planning. This inventory project exemplified a transdisciplinary research, in which researchers and societal stakeholders collaborated for co-design of research agendas, co-production of knowledge, and co-dissemination of outcomes.

  4. 77 FR 4368 - Abbott Laboratories, Diagnostics Division, Including On-Site Leased Workers From Manpower...

    Science.gov (United States)

    2012-01-27

    ... Employment and Training Administration Abbott Laboratories, Diagnostics Division, Including On-Site Leased..., Diagnostics Division, including on-site leased workers from Manpower, Comsys, Apex, Fountain Group, Kelly... location of Abbott Laboratories, Diagnostics Division. The Department has determined that these...

  5. 75 FR 879 - National Semiconductor Corporation Arlington Manufacturing Site Including On-Site Leased Workers...

    Science.gov (United States)

    2010-01-06

    ... Employment and Training Administration National Semiconductor Corporation Arlington Manufacturing Site... Semiconductor Corporation, Arlington Manufacturing Site, including on-site leased workers from GCA, CMPA, Custom... Mechanical Systems were employed on-site at the Arlington, Texas location of National...

  6. 75 FR 55613 - General Motors Corporation, Renaissance Center, Including On-Site Leased Workers From Accretive...

    Science.gov (United States)

    2010-09-13

    ... Employment and Training Administration General Motors Corporation, Renaissance Center, Including On-Site... of General Motors Corporation, Renaissance Center, including on-site leased workers from Accretive... location of General Motors Corporation, Renaissance Center. The Department has determined that on-site...

  7. Project VISION (Very Intensive Scientific Intercurricular On-Site Education

    Science.gov (United States)

    Roig, Gustavo A.

    1999-01-01

    Project VISION (Very Intensive Scientific Intercurricular On-Site Education) is a joint effort among NASA/John F. Kennedy Space Center, Florida International University, Universidad del Turabo, Miami-Dade County Public Schools and the Caguas/Gurabo Public Schools in Puerto Rico. The project's main mission is to institutionalize change among the elementary and middle school science and math teachers at participating schools so that their students receive continuously enriched instruction in the principles of science and math through the use of hands-on and minds-on experiments called learning modules. These leaming modules incorporate the national science and math education standards provided by the National Committee on Science Education Standards and Assessments and the National Council of Teachers of Mathematics, respectively. The use of learning modules that require hands-on and minds-on activities in a classroom setting garners great enthusiasm and motivation on the part of the target students for the understanding of the lesson's underlying math and science principles. With this enthusiasm and motivation, comes acceptance, attention, participation, discipline, acquiescence, and collaboration. Additionally, the use of hands-on activities may also require learning through a gamut of senses. Not only can the student use his/her eyes and ears during these activities, but most times, they can also use their senses of touch, smell, and taste, as well as intuition. Learning is, therefore, achieved using most or all the human senses. The combination of motivation/enthusiasm and the use of multiple senses creates an ideal environment conducive to leaming at a profound level.

  8. Study of component technologies for fuel cell on-site integrated energy systems

    Science.gov (United States)

    Lee, W. D.; Mathias, S.

    1980-01-01

    Heating, ventilation and air conditioning equipment are integrated with three types of fuel cells. System design and computer simulations are developed to utilize the thermal energy discharge of the fuel in the most cost effective manner. The fuel provides all of the electric needs and a loss of load probability analysis is used to ensure adequate power plant reliability. Equipment cost is estimated for each of the systems analyzed. A levelized annual cost reflecting owning and operating costs including the cost of money was used to select the most promising integrated system configurations. Cash flows are presented for the most promising 16 systems. Several systems for the 96 unit apartment complex (a retail store was also studied) were cost competitive with both gas and electric based conventional systems. Thermal storage is shown to be beneficial and the optimum absorption chiller sizing (waste heat recovery) in connection with electric chillers are developed. Battery storage was analyzed since the system is not electric grid connected. Advanced absorption chillers were analyzed as well. Recommendations covering financing, technical development, and policy issues are given to accelerate the commercialization of the fuel cell for on-site power generation in buildings.

  9. REPORT OF ON-SITE INSPECTION WORKSHOP-16

    Energy Technology Data Exchange (ETDEWEB)

    Sweeney, J J

    2009-07-07

    The central issue addressed by this workshop was the task of making the on-site inspection (OSI) part of the Comprehensive Nuclear-Test-Ban Treaty verification system operationally ready at entry into force of the Treaty. It is recognized, and this was emphasized by the 2008 OSI Integrated Field Exercise (IFE), that it is not possible to develop every part of the OSI regime simultaneously. Therefore, it is necessary to prioritize the approach to OSI readiness. The reviews of the IFE have pointed to many elements of OSI readiness that still need development. The objective of this workshop was to provide priorities for the path forward for Working Group B to consider. Several critical areas have been identified that are related to the development of OSI readiness: (1) Technology development: Priorities are radionuclide and noble gas sampling and analysis, visual observation, multispectral/infrared imaging methods, active seismic methods and the recognition of the importance of signatures. (2) Organizational development: Priorities are health and safety, the Operations Support Centre, the Equipment Storage and Maintenance Facility, information technology data flow and communications. (3) Resources: The expertise to develop key parts of the OSI regime is not available within the current OSI Division staff. To develop these aspects of the regime will require more staff or supplements to the staff with cost-free experts or other means. Aspects of the system that could benefit from more staff include radionuclide and noble gas detection methods, data flow and communications, visual observation, multispectral/infrared methods and health and safety. As the path forward, participants of this workshop recognized a need to optimize the development of OSI priorities. The outcome of this workshop is to suggest for consideration an operational approach to OSI readiness that utilizes results of an evaluation of the relative effectiveness of OSI elements versus their relative

  10. Global Scale Methane Emissions from On-Site Wastewater Management

    Science.gov (United States)

    Reid, M. C.; Guan, K.; Mauzerall, D. L.

    2013-12-01

    Pit latrines and other on-site sanitation methods are important forms of wastewater management at the global scale, providing hygienic and low-cost sanitation for more than 1.7 billion people in developing and middle-income regions. Latrines have also been identified as major sources of the greenhouse gas methane (CH4) from the anaerobic decomposition of organic waste in pits. Understanding the greenhouse gas footprint of different wastewater systems is essential for sustainable water resource development and management. Despite this importance, CH4 emissions from decentralized wastewater treatment have received little attention in the scientific literature, and the rough calculations underlying government inventories and integrated assessment models do not accurately capture variations in emissions within and between countries. In this study, we improve upon earlier efforts and develop the first spatially explicit approach to quantifying latrine CH4 emissions, combining a high-resolution geospatial analysis of population, urbanization, and water table (as an indicator of anaerobic decomposition pathways) with CH4 emissions factors from the 2006 IPCC Guidelines for National Greenhouse Gas Inventories. Country-level health and sanitation surveys were used to determine latrine utilization in 2000 and predict usage in 2015. 18 representative countries in Asia, Africa, and Latin America were selected for this analysis to illustrate regional variations in CH4 emissions and to include the greatest emitting nations. Our analysis confirms that pit latrines are a globally significant anthropogenic CH4 source, emitting 4.7 Tg CH4 yr-1 in the countries considered here. This total is projected to decrease ~25% by 2015, however, driven largely by rapid urbanization in China and decreased reliance on latrines in favor of flush toilets. India has the greatest potential for large growth in emissions in the post-2015 period, since public health campaigns to end open defecation

  11. Activities dedicated to FCPP commercialization at Toshiba

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Shin-ichi; Ozono, Jiro; Sato, Nobuaki [Toshiba Corp., Tokyo (Japan)

    1996-12-31

    The present line-up of fuel cell power plants (FCPPs) at Toshiba consists of 11MW FCPP for pressurized operation, 1000kW on-site FCPP and 200kW on-site FCPP. In these, an 11MW FCPP installed at Goi Power Station of Tokyo Electric Power Company (TEPCO) is providing valuable experience through more than 20,000 cumulative hours of operation. Also, a 1000kW on-site FCPP, which Toshiba manufactured under the joint program of NEDO and PAFC Technology Research Association, has cumulative operation of 7,500 hours. Toshiba, however, believes that the 200kW on-site FCPP is the leader in the commercialization of phosphoric acid FCPP. This paper therefore presents the development status of 200kW power plants and our strategic considerations for full commercialization of PC25 type 200kW FCPP.

  12. Static and dynamic stress analyses of the prototype high head Francis runner based on site measurement

    Science.gov (United States)

    Huang, X.; Oram, C.; Sick, M.

    2014-03-01

    More efforts are put on hydro-power to balance voltage and frequency within seconds for primary control in modern smart grids. This requires hydraulic turbines to run at off-design conditions. especially at low load or speed-no load. Besides. the tendency of increasing power output and decreasing weight of the turbine runners has also led to the high level vibration problem of the runners. especially high head Francis runners. Therefore. it is important to carry out the static and dynamic stress analyses of prototype high head Francis runners. This paper investigates the static and dynamic stresses on the prototype high head Francis runner based on site measurements and numerical simulations. The site measurements are performed with pressure transducers and strain gauges. Based on the measured results. computational fluid dynamics (CFD) simulations for the flow channel from stay vane to draft tube cone are performed. Static pressure distributions and dynamic pressure pulsations caused by rotor-stator interaction (RSI) are obtained under various operating conditions. With the CFD results. static and dynamic stresses on the runner at different operating points are calculated by means of the finite element method (FEM). The agreement between simulation and measurement is analysed with linear regression method. which indicates that the numerical result agrees well with that of measurement. Furthermore. the maximum static and dynamic stresses on the runner blade are obtained at various operating points. The relations of the maximum stresses and the power output are discussed in detail. The influences of the boundary conditions on the structural behaviour of the runner are also discussed.

  13. Industrial paramedics, out on site but not out of mind.

    Science.gov (United States)

    Acker, Joseph J; Johnston, Tania M; Lazarsfeld-Jensen, Ann

    2014-01-01

    (MOEMS). There is no single definition or comprehensive role description for industrial paramedic practice within the literature. Worldwide, there is little high-quality published evidence to adequately reflect all aspects of industrial paramedic practice. However, based on the literature available, this definition is offered: 'An industrial paramedic is an advanced clinical practitioner in paramedicine with an expanded scope of practice. The industrial paramedic provides emergency response, primary health care, chronic disease management, injury prevention, health promotion, medical referral, and repatriation coordination at remote mining sites, offshore installations, and other isolated industry settings. The industrial paramedic is resourceful, adaptable, and comfortable working independently. Industrial paramedics practice on site with limited resources, remotely located from tertiary care, and use telemedicine to consult with other health professionals as required. Industrial paramedics are experts at rapidly assessing, prioritising, and establishing control in their unpredictable workspace to reduce risks and create an environment conducive to quality patient care. The industrial paramedic preferably holds a specialised tertiary qualification and is committed to maintaining their clinical competency through continuing professional development.' Further research is required to validate, refute, or expand this proposed definition.

  14. An updated assessment of the prospects for fuel cell-powered buses. An information paper

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, T.K. [Future Energy Solutions, Harwell (United Kingdom)

    2005-07-01

    This report presents updated conclusions of the Department of Trade and Industry's research and development programme to assess the commercial prospects for advanced fuel cells in buses. The programme has focussed on low temperature solid polymer fuel cells (SPFCs) for transport and combined heat and power (CHP)/distributed power and high temperature solid oxide fuel cells (SOFCs) for CHP/distributed power. As well as assessing the prospects for SPFCs in buses, the report examines those for alkaline fuel cells (AFCs) and phosphoric acid fuel cells (PAFCs) in buses. The report provides an assessment of the status of technology development for different types of fuel cells in terms of applications to buses and offers estimates of market potential. Some fuel-cell powered buses are now available for demonstration purposes but the report concludes that truly commercial sales are unlikely to start before 2010 and widespread deployment is expected to take a further ten years after that. Buses have now slipped behind cars in terms of worldwide deployment. The issue of fuel choice is considered largely resolved with most fleet vehicle/bus manufacturers currently focussing on hydrogen as a fuel. A discussion of the prospects and barriers for fuel cell buses concludes that cost reduction is now the major barrier to the successful commercialisation of fuel cells in buses. More demonstration prototypes and field trials are required to provide information on energy, environmental and economic performance of fuel cell buses. Field trials could also provide information to assist the development of refuelling systems, fuel storage systems, stacks and other system components and to gain experience of building integrated fuel cell systems.

  15. First On-Site True Gamma-Ray Imaging-Spectroscopy of Contamination near Fukushima Plant

    Science.gov (United States)

    Tomono, Dai; Mizumoto, Tetsuya; Takada, Atsushi; Komura, Shotaro; Matsuoka, Yoshihiro; Mizumura, Yoshitaka; Oda, Makoto; Tanimori, Toru

    2017-01-01

    We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in the vicinity of the Fukushima Daiichi Nuclear Power Plants in Japan in 2014. The obtained distribution of brightness (or emissivity) with remote-sensing observations is unambiguously converted into the dose distribution. We confirm that the dose distribution is consistent with the one taken by conventional mapping measurements with a dosimeter physically placed at each grid point. Furthermore, its imaging spectroscopy, boosted by Compton-edge-free spectra, reveals complex radioactive features in a quantitative manner around each individual target point in the background-dominated environment. Notably, we successfully identify a “micro hot spot” of residual caesium contamination even in an already decontaminated area. These results show that the ETCC performs exactly as the geometrical optics predicts, demonstrates its versatility in the field radiation measurement, and reveals potentials for application in many fields, including the nuclear industry, medical field, and astronomy. PMID:28155883

  16. First On-Site True Gamma-Ray Imaging-Spectroscopy of Contamination near Fukushima Plant

    Science.gov (United States)

    Tomono, Dai; Mizumoto, Tetsuya; Takada, Atsushi; Komura, Shotaro; Matsuoka, Yoshihiro; Mizumura, Yoshitaka; Oda, Makoto; Tanimori, Toru

    2017-02-01

    We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in the vicinity of the Fukushima Daiichi Nuclear Power Plants in Japan in 2014. The obtained distribution of brightness (or emissivity) with remote-sensing observations is unambiguously converted into the dose distribution. We confirm that the dose distribution is consistent with the one taken by conventional mapping measurements with a dosimeter physically placed at each grid point. Furthermore, its imaging spectroscopy, boosted by Compton-edge-free spectra, reveals complex radioactive features in a quantitative manner around each individual target point in the background-dominated environment. Notably, we successfully identify a “micro hot spot” of residual caesium contamination even in an already decontaminated area. These results show that the ETCC performs exactly as the geometrical optics predicts, demonstrates its versatility in the field radiation measurement, and reveals potentials for application in many fields, including the nuclear industry, medical field, and astronomy.

  17. The On-Site Status of the Kstar Helium Refrigeration System

    Science.gov (United States)

    Chang, H.-S.; Park, D. S.; Joo, J. J.; Moon, K. M.; Cho, K. W.; Kim, Y. S.; Bak, J. S.; Kim, H. M.; Cho, M. C.; Kwon, I. K.; Fauve, E.; Bernhardt, J.-M.; Dauguet, P.; Beauvisage, J.; Andrieu, F.; Yang, S.-H.; Baguer, G. M. Gistau

    2008-03-01

    Since the first design of the KSTAR helium refrigeration system (HRS) in year 2000, many modifications and changes have been applied due to both system optimization and improved knowledge of the KSTAR cold components. The present specification of the HRS had been fixed on March, 2005. Consequent manufacturing of main equipment, such as "Compressor Station" (C/S), "Cold Box" (C/B), and "Distribution Box ♯1" (D/B ♯1) was completed by or under the supervision of Air Liquide DTA by the end of year 2006. The major components of the C/S are 2 low and 2 high pressure compressor units and an oil-removal system. The cooling power of the C/B at 4.5 K equivalent is 9 kW achieved by using 6 turbo-expanders. The D/B ♯1 is a cryostat housing 49 cryogenic valves, 2 supercritical helium circulators, 1 cold compressor, and 7 heat exchangers immersed in a 6 m3 liquid helium storage. In this proceeding, the on-site installation and commissioning status of the HRS will be presented. In addition, the final specification and design features of the HRS and the

  18. A Portable and Autonomous Mass Spectrometric System for On-Site Environmental Gas Analysis.

    Science.gov (United States)

    Brennwald, Matthias S; Schmidt, Mark; Oser, Julian; Kipfer, Rolf

    2016-12-20

    We developed a portable mass spectrometric system ("miniRuedi") for quantificaton of the partial pressures of He, Ne (in dry gas), Ar, Kr, N2, O2, CO2, and CH4 in gaseous and aqueous matrices in environmental systems with an analytical uncertainty of 1-3%. The miniRuedi does not require any purification or other preparation of the sampled gases and therefore allows maintenance-free and autonomous operation. The apparatus is most suitable for on-site gas analysis during field work and at remote locations due to its small size (60 cm × 40 cm × 14 cm), low weight (13 kg), and low power consumption (50 W). The gases are continuously sampled and transferred through a capillary pressure reduction system into a vacuum chamber, where they are analyzed using a quadrupole mass spectrometer with a time resolution of ≲1 min. The low gas consumption rate (<0.1 mL/min) minimizes interference with the natural mass balance of gases in environmental systems, and allows the unbiased quantification of dissolved-gas concentrations in water by gas/water equilibration using membrane contractors (gas-equilibrium membrane-inlet mass spectrometry, GE-MIMS). The performance of the miniRuedi is demonstrated in laboratory and field tests, and its utility is illustrated in field applications related to soil-gas formation, lake/atmosphere gas exchange, and seafloor gas emanations.

  19. Probabilistic Risk Assessment of Cask Drop Accident during On-site Spent Nuclear Fuel Transportation

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Jae Hyun; Christian, Robby; Momani, Belal Al; Kang, Hyun Gook [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    There are two ways to transfer the SNF from a site to other site, one is land transportation and the other is maritime transportation. Maritime transportation might be used because this way uses more safe route which is far from populated area. The whole transportation process can be divided in two parts: transferring the SNF between SNP and wharf in-Nuclear Power Plant (NPP) site by truck, and transferring the SNF from the wharf to the other wharf by ship. In this research, on-site SNF transportation between SNP and wharf was considered. Two kinds of single accident can occur during this type of SNF transportation, impact and fire, caused by internal events and external events. In this research, PRA of cask drop accident during onsite SNF transportation was done, risk to a person (mSv/person) from a case with specific conditions was calculated. In every 11 FEM simulation drop cases, FDR is 1 even the fuel assemblies are located inside of the cask. It is a quite larger value for all cases than the results with similar drop condition from the reports which covers the PRA on cask storage system. Because different from previous reports, subsequent impact was considered. Like in figure 8, accelerations which are used to calculate the FDR has extremely higher values in subsequent impact than the first impact for all SNF assemblies.

  20. Preliminary survey on site-adaptation techniques for satellite-derived and reanalysis solar radiation datasets

    Energy Technology Data Exchange (ETDEWEB)

    Polo, J.; Wilbert, S.; Ruiz-Arias, J. A.; Meyer, R.; Gueymard, C.; Súri, M.; Martín, L.; Mieslinger, T.; Blanc, P.; Grant, I.; Boland, J.; Ineichen, P.; Remund, J.; Escobar, R.; Troccoli, A.; Sengupta, M.; Nielsen, K. P.; Renne, D.; Geuder, N.; Cebecauer, T.

    2016-07-01

    At any site, the bankability of a projected solar power plant largely depends on the accuracy and general quality of the solar radiation data generated during the solar resource assessment phase. The term 'site adaptation' has recently started to be used in the framework of solar energy projects to refer to the improvement that can be achieved in satellite-derived solar irradiance and model data when short-term local ground measurements are used to correct systematic errors and bias in the original dataset. This contribution presents a preliminary survey of different possible techniques that can improve long-term satellite-derived and model-derived solar radiation data through the use of short-term on-site ground measurements. The possible approaches that are reported here may be applied in different ways, depending on the origin and characteristics of the uncertainties in the modeled data. This work, which is the first step of a forthcoming in-depth assessment of methodologies for site adaptation, has been done within the framework of the International Energy Agency Solar Heating and Cooling Programme Task 46 'Solar Resource Assessment and Forecasting.'

  1. Agile sustainable communities. On-site renewable energy generation

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Woodrow W. II. [A. Gary Anderson Graduate School of Management, University of California, Riverside (United States); Eisenberg, Larry [Los Angeles Community College District (United States)

    2008-12-15

    Smart and sustainable campuses demand three components. First, there is the need to have a Strategic Master Plan (SMP) for all infrastructures that include energy, transportation, water, waste and telecommunications along with the traditional dimensions of research, curricula, outreach and assessments. Secondarily, there is the array of issues pertaining to the sitting of buildings and overall facility master planning which must be addressed from the perspective of 'green' energy, efficient orientation and be designed for multiple-use by the academic and local community. Thirdly, the development of sustainable buildings in one area that is compact and walkable campuses thus enable a range of transportation choices leads to reduced energy consumption. Historically, college campuses were often like towns and villages in that they are self-sustaining for family, business and recreational activities. Any sustainable smart campus is a vibrant, 'experiential' applied educational model that should catalyze creative learning. More significantly, today, campuses and communities must be secure in terms of not only their own energy use and needs, but also for the resource demands of their power. Otherwise, the community(s) will never be secure economically or politically. Recognizing global warming and climate change, in the spring of 2001, the Board of Trustee (BOT) for the Los Angeles Community College District (LACCD) took the critical initial policy steps to turn these sustainable developments into goals. For example, the LACCD decided to have new 'green' buildings to replace or renovate existing ones. The building program led to sustainable communities that included recycling, product reuse from waste as well as smart growth in terms of reduced energy use, efficiency and the use of telecommunication and wireless systems. The paper focuses primarily on the energy programs for the LACCD campuses. The paper considers the overall energy

  2. 78 FR 48468 - Delphi Corporation, Electronics and Safety Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-08-08

    ... Employment and Training Administration Delphi Corporation, Electronics and Safety Division, Including On-Site... to workers of Delphi Corporation, Electronics and Safety Division, including on-site leased workers... Delphi Corporation, Electronics and Safety Division. The Department has determined that these...

  3. 75 FR 70688 - Actel Corporation, Currently Known as Microsemi Corporation, Including On-Site Leased Workers...

    Science.gov (United States)

    2010-11-18

    ... On-Site Leased Workers From ATR International, Accountants, Inc. and Accountant Temps Mountain View... International, Accountants, Inc., and Accountant Temps, Mountain View, California. The notice was published in... Microsemi Corporation, including on-site leased workers from ATE International, Accountants, Inc.,...

  4. 75 FR 62423 - Barnstead Thermolyne Corporation, a Subsidiary of Thermo Fisher Scientific, Including On-Site...

    Science.gov (United States)

    2010-10-08

    ...] Barnstead Thermolyne Corporation, a Subsidiary of Thermo Fisher Scientific, Including On-Site Leased Workers... subsidiary of Thermo Fisher Scientific, including on- site leased workers from Sedona Staffing, Dubuque, Iowa... Thermolyne Corporation, a subsidiary of Thermo Fisher Scientific. The Department has determined that...

  5. 75 FR 28295 - Cummins Filtration, Including On-Site Leased Workers From Manpower and Spherion Staffing...

    Science.gov (United States)

    2010-05-20

    ... Employment and Training Administration Cummins Filtration, Including On-Site Leased Workers From Manpower and... workers of Cummins Filtration, including on-site leased workers from Manpower, Lake Mills, Iowa. The... Mills, Iowa location of Cummins Filtration to provide procurement and inventory management services...

  6. 13 CFR 120.1051 - Frequency of on-site reviews and examinations.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Frequency of on-site reviews and examinations. 120.1051 Section 120.1051 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Risk-Based Lender Oversight Supervision § 120.1051 Frequency of on-site reviews and...

  7. 75 FR 3250 - Glaxosmithkline, Including On-Site Temporary and Leased Workers From Kelly Services, Kelly...

    Science.gov (United States)

    2010-01-20

    ... antibiotics for humans and animals. The company reports that on-site leased workers from Dream Clean, Inc..., Pharmasys, Validation System Solutions, Tele-Optics and Dream Clean, Inc., Bristol, TN; Amended... from Dream Clean, Inc. working on-site at the Bristol, Tennessee location of Glaxosmithkline. The...

  8. 78 FR 32464 - Amantea Nonwovens, LLC, Including On-Site Leased Workers From Express Employment Professionals...

    Science.gov (United States)

    2013-05-30

    ... Employment and Training Administration Amantea Nonwovens, LLC, Including On-Site Leased Workers From Express... Nonwovens, L.L.C. including on-site leased workers from Express Employment Professionals and The Job Store..., Ohio location of Amantea Nonwovens, L.L.C. The Department has determined that these workers were...

  9. 13 CFR 120.1050 - On-site reviews and examinations.

    Science.gov (United States)

    2010-01-01

    .../liability management); (4) Earnings; (5) Liquidity; and (6) Compliance with Loan Program Requirements. (c... Risk-Based Lender Oversight Supervision § 120.1050 On-site reviews and examinations. (a) On-site... operations management; (3) Credit administration; and (4) Compliance with Loan Program Requirements. (b)...

  10. Laboratory and clinical evaluation of on-site urine drug testing.

    Science.gov (United States)

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  11. On-site Rapid Diagnosis of Intracranial Hematoma using Portable Multi-slice Microwave Imaging System

    Science.gov (United States)

    Mobashsher, Ahmed Toaha; Abbosh, A. M.

    2016-11-01

    Rapid, on-the-spot diagnostic and monitoring systems are vital for the survival of patients with intracranial hematoma, as their conditions drastically deteriorate with time. To address the limited accessibility, high costs and static structure of currently used MRI and CT scanners, a portable non-invasive multi-slice microwave imaging system is presented for accurate 3D localization of hematoma inside human head. This diagnostic system provides fast data acquisition and imaging compared to the existing systems by means of a compact array of low-profile, unidirectional antennas with wideband operation. The 3D printed low-cost and portable system can be installed in an ambulance for rapid on-site diagnosis by paramedics. In this paper, the multi-slice head imaging system’s operating principle is numerically analysed and experimentally validated on realistic head phantoms. Quantitative analyses demonstrate that the multi-slice head imaging system is able to generate better quality reconstructed images providing 70% higher average signal to clutter ratio, 25% enhanced maximum signal to clutter ratio and with around 60% hematoma target localization compared to the previous head imaging systems. Nevertheless, numerical and experimental results demonstrate that previous reported 2D imaging systems are vulnerable to localization error, which is overcome in the presented multi-slice 3D imaging system. The non-ionizing system, which uses safe levels of very low microwave power, is also tested on human subjects. Results of realistic phantom and subjects demonstrate the feasibility of the system in future preclinical trials.

  12. On-site gamma dose rates at the Andreeva Bay shore technical base, northwest Russia.

    Science.gov (United States)

    Reistad, O; Dowdall, M; Standring, W J F; Selnaes, Ø G; Hustveit, S; Steinhusen, F; Sørlie, A

    2008-07-01

    The spent nuclear fuel (SNF) and radioactive waste (RAW) storage facility at Andreeva Bay shore technical base (STB) is one of the largest and most hazardous nuclear legacy sites in northwest Russia. Originally commissioned in the 1960s the facility now stores large amounts of SNF and RAW associated with the Russian Northern Fleet of nuclear powered submarines. The objective of the present study was to map ambient gamma dose rates throughout the facility, in particular at a number of specific sites where SNF and RAW are stored. The data presented here are taken from a Norwegian-Russian collaboration enabling the first publication in the scientific literature of the complete survey of on-site dose rates. Results indicate that elevated gamma dose rates are found primarily at discrete sites within the facility; maximum dose rates of up to 1000 microSv/h close to the ground (0.1m) and up to 3000 microSv/h at 1m above ground were recorded, higher doses at the 1m height being indicative primarily of the presence of contaminated equipment as opposed to ground contamination. Highest dose rates were measured at sites located in the immediate vicinity of buildings used for storing SNF and sites associated with storage of solid and liquid radioactive wastes. Elevated dose rates were also observed near the former channel of a small brook that became heavily contaminated as a result of radioactive leaks from the SNF storage at Building 5 starting in 1982. Isolated patches of elevated dose rates were also observed throughout the STB. A second paper detailing the radioactive soil contamination at the site is published in this issue of Journal of Environmental Radioactivity.

  13. A smartphone-based colorimetric reader coupled with a remote server for rapid on-site catechols analysis.

    Science.gov (United States)

    Wang, Yun; Li, Yuanyuan; Bao, Xu; Han, Juan; Xia, Jinchen; Tian, Xiaoyu; Ni, Liang

    2016-11-01

    The search of a practical method to analyze cis-diol-containing compounds outside laboratory settings remains a substantial scientific challenge. Herein, a smartphone-based colorimetric reader was coupled with a remote server for rapid on-site analysis of catechols. A smallest-scale 2×2 colorimetric sensor array composed of pH indicators and phenylboronic acid was configured. The array was able to distinguish 13 catechols at 6 serial concentrations, through simultaneous treatment via principal component analysis, hierarchical cluster analysis, and linear discriminant analysis. After both the discriminatory power of the array and the prediction ability of the partial least squares quantitative models were proved to be predominant, the smartphone was coupled to the remote server. All the ΔRGB data were uploaded to the remote server wherein linear discriminant analysis and partial least squares processing modules were established to provide qualitative discrimination and quantitative calculation, respectively, of the analytes in real time. The applicability of this novel method to a real-life scenario was confirmed by the on-site analysis of various catechols from a water sample of the Yangtze River; the feedback result in the smartphone showed the method was able to identify the catechols with 100% accuracy and predict the concentrations to within 0.706-2.240 standard deviation.

  14. 76 FR 2144 - Quest Diagnostics, Inc. Information Technology Help Desk Services Including On-Site Leased...

    Science.gov (United States)

    2011-01-12

    ... Employment and Training Administration Quest Diagnostics, Inc. Information Technology Help Desk Services... for Worker Adjustment Assistance on December 6, 2010, applicable to workers of Quest Diagnostics, Inc... on-site at the West Norriton, Pennsylvania location of Quest Diagnostics, Inc.,...

  15. 78 FR 8587 - Thomson Reuters, Finance Operations & Technology Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-02-06

    ... Employment and Training Administration Thomson Reuters, Finance Operations & Technology Division, Including... Worker Adjustment Assistance on August 2, 2012, applicable to workers of Thomson Reuters, Finance... that workers of Thomson Reuters, Finance Operations & Technology Division, including on-site...

  16. A sensitive rapid on-site immunoassay for heavy metal contamination

    Energy Technology Data Exchange (ETDEWEB)

    Blake, R.; Blake, D.; Flowers, G.

    1996-05-02

    This project concerns the development of immunoassays for heavy metals that will permit the rapid on-site analysis of specific heavy metals, including lead and chromium in water and soil samples. 2 refs.

  17. Comparison of conventional vs. modular hydrogen refueling stations and on-site production vs. delivery.

    Energy Technology Data Exchange (ETDEWEB)

    Hecht, Ethan S. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Pratt, Joseph William [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2017-03-01

    To meet the needs of public and private stakeholders involved in the development, construction, and operation of hydrogen fueling stations needed to support the widespread roll-out of hydrogen fuel cell electric vehicles, this work presents publicly available station templates and analyses. These ‘Reference Stations’ help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enable quick assessment of potential sites for a hydrogen station, identify contributors to poor economics, and suggest areas of research. This work presents layouts, bills of materials, piping and instrumentation diagrams, and detailed analyses of five new station designs. In the near term, delivered hydrogen results in a lower cost of hydrogen compared to on-site production via steam methane reforming or electrolysis, although the on-site production methods have other advantages. Modular station concepts including on-site production can reduce lot sizes from conventional assemble-on-site stations.

  18. On-site toxicity of irrigation drainwater from Stillwater National Wildlife Refuge to aquatic organisms

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The toxicity of water from seven locations in the Stillwater Wildlife Management Area was evaluated in a series of on-site tests conducted over a 10 day period with...

  19. 75 FR 11922 - Apria Healthcare, Including On-Site Leased Workers From Corestaff, Ultimate Staffing (Roth...

    Science.gov (United States)

    2010-03-12

    ..., Ultimate Staffing (Roth Staffing Companies), and Aerotek, Cromwell, CT; Amended Certification Regarding... a separate unemployment insurance (UI) tax account for Roth Staffing Companies. The Department has... from Ultimate Staffing (Roth Staffing Companies) and Aerotek working on-site at the...

  20. 78 FR 66779 - United States Enrichment Corporation, Paducah Gaseous Diffusion Plant, Including On-Site Leased...

    Science.gov (United States)

    2013-11-06

    ... Employment and Training Administration United States Enrichment Corporation, Paducah Gaseous Diffusion Plant... Corporation, Paducah Gaseous Diffusion Plant, including on-site leased workers from Diversified Management...: All workers of United States Enrichment Corporation, Paducah Gaseous Diffusion Plant,......

  1. Field Sampling and Selecting On-Site Analytical Methods for Explosives in Soil

    Science.gov (United States)

    The purpose of this issue paper is to provide guidance to Remedial Project Managers regarding field sampling and on-site analytical methods fordetecting and quantifying secondary explosive compounds in soils.

  2. 75 FR 49526 - Halliburton Company, Duncan Mfg., Including On-Site Leased Workers from Express Personnel...

    Science.gov (United States)

    2010-08-13

    ... Employment and Training Administration Halliburton Company, Duncan Mfg., Including On-Site Leased Workers... Company, Technology and Engineering Division, Finance and Administration Division, Duncan, OK; Amended.... Workers of Halliburton Company, Technology and Engineering Division, and Finance and...

  3. 75 FR 71464 - Metlife Technology, Operations, and Information Technology Groups Including On-Site Leased...

    Science.gov (United States)

    2010-11-23

    ... Employment and Training Administration Metlife Technology, Operations, and Information Technology Groups... Moosic, PA, Metlife Technology, Operations, and Information Technology Groups Including On-Site Leased... of MetLife, Technology, Operations, and Information Technology Groups, Moosic, Pennsylvania...

  4. Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran

    OpenAIRE

    Hassan Taghipour; Mina Alizadeh; Reza Dehghanzadeh; Mohammad Reza Farshchian; Mohammad Ganbari; Mohammad Shakerkhatibi

    2016-01-01

    Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment) was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The...

  5. A Study on Usage of on-site Multi-monitoring System in Laser Processing of Paper Materials

    Science.gov (United States)

    Piili, Heidi

    Laser technology provides advantages for paper material processing as it is non-contact method and provides freedom of geometry and reliable technology for non-stop production. Reason for low utilization of lasers in paper manufacturing is lack of published research. This is main reason to study utilization of on-site multi-monitoring system (MMS) in characterization of interaction between laser beam and paper materials. Target of MMS is to be able to control processing of paper, but also to get better understanding of basic phenomena. Laser equipment used was TRUMPF TLF 2700 CO2 laser (wavelength 10.6 μm) with power range of 190-2500 W. MMS consisted of spectrometer, pyrometer and active illumination imaging system. This on-site study was carried out by treating dried kraft pulp (grammage of 67 g m-2) with different laser power levels, focal plane position settings and interaction times. It was concluded that spectrometer and pyrometer are best devices in MMS; set-up of them to laser process is easy, they detect data fast enough and analysis of data is easy afterwards. Active illumination imaging system is capable for capturing images of different phases of interaction but analysis of images is time-consuming. When active illumination imaging system is combined with spectrometer and pyrometer i.e. using of MMS, it reveals basic phenomena occurring during interaction. For example, it was noticed that holes created after laser exposure are formed gradually. Firstly, small hole is formed to interaction area and after that hole expands, until interaction is ended.

  6. On-Site Energy Management by Integrating Campus Buildings and Optimizing Local Energy Systems, Case Study of the Campus in Finland

    Directory of Open Access Journals (Sweden)

    Genku Kayo

    2016-12-01

    Full Text Available This research work describes the potential study on the impact of energy improvements of existing campus buildings by on-site energy management and operational strategies. The focus buildings in the campus are mainly built in the 1960s, and therefore it is time to carry out renovation work. In connection with renovations, the aim is to improve the energy efficiency of the buildings, and to develop the functionality of the properties to meet the current requirements. Thus, in this study, the potentials of on-site energy generation and sharing in the cluster of campus buildings in Finland were studied. By means of optimisation method, the optimal combined heat and power systems (CHP capacity distribution and operation mode for minimizing annual primary energy consumption were simulated. The results show the integration of buildings has advantage for on-site energy management as 23% of primary energy reduction compared with current situation. Consequently, integrating buildings and optimizing on-site energy management can be one of effective strategies for minimizing primary energy consumption. Furthermore, the study to improve operation strategies of building service system considering current space use in the building clarified that up to 13% of total energy use reduction is expected. The research work also proposes the way of providing environmental information to increase awareness of building energy usage in the campus.

  7. Acoustic-Seismic Coupling in Porous Ground - Measurements and Analysis for On-Site-Inspection Support

    Science.gov (United States)

    Liebsch, Mattes; Gorschlüter, Felix; Altmann, Jürgen

    2014-05-01

    acoustic signals and geophones were buried in different depths to measure the soil velocity. Additionally, a wooden box coated with acoustic damping foam was placed over some acoustic and seismic sensors to reduce the power of incident acoustic signals and thus the locally created seismic vibrations (under the box). The reduced soil velocity measured by geophones under the box corresponds mainly to vibrations created by acoustic-seismic coupling outside the box which travel through the soil and reach the sensor. Under certain conditions of frequency and incident angle of acoustic signals an increased seismic response was observed. This might indicate the excitation of seismic surface waves and is of special interest for the evaluation. The project aims to deliver a better understanding of the interaction of acoustic waves with the ground when hitting the surface. Recommendations for sensitive seismic measurements during CTBTO on-site inspections will be developed to reduce disturbing vibrations caused by airborne sources.

  8. 75 FR 26797 - Cummins Power Generation, Including On-Site Leased Workers of Adecco USA, Inc., Aerotek, Inc...

    Science.gov (United States)

    2010-05-12

    ... Group, Back Diamonds Networks, Entegee, Inc., DBA Midstates Technical, Manpower, Inc., Robert Half... import articles like or directly competitive with the generators and transfer switches produced at the... articles abroad during the same period. The investigation also revealed that, during the relevant period...

  9. Development and on-site field testing of the power-tube airlift aerator and chances for commercialization

    Science.gov (United States)

    Aeration of ponds when dissolved oxygen (DO) concentrations are low is the principal management tool that allows for higher feeding rates, increased production, and decreased cost per unit fish produced. Recent research conducted at the USDA-ARS Warmwater Aquaculture Research Unit has shown that fee...

  10. Slope stability and bearing capacity of landfills and simple on-site test methods.

    Science.gov (United States)

    Yamawaki, Atsushi; Doi, Yoichi; Omine, Kiyoshi

    2017-07-01

    This study discusses strength characteristics (slope stability, bearing capacity, etc.) of waste landfills through on-site tests that were carried out at 29 locations in 19 sites in Japan and three other countries, and proposes simple methods to test and assess the mechanical strength of landfills on site. Also, the possibility of using a landfill site was investigated by a full-scale eccentric loading test. As a result of this, landfills containing more than about 10 cm long plastics or other fibrous materials were found to be resilient and hard to yield. An on-site full scale test proved that no differential settlement occurs. The repose angle test proposed as a simple on-site test method has been confirmed to be a good indicator for slope stability assessment. The repose angle test suggested that landfills which have high, near-saturation water content have considerably poorer slope stability. The results of our repose angle test and the impact acceleration test were related to the internal friction angle and the cohesion, respectively. In addition to this, it was found that the air pore volume ratio measured by an on-site air pore volume ratio test is likely to be related to various strength parameters.

  11. Evaluation of a human on-site urine multidrug test for emergency use with dogs.

    Science.gov (United States)

    Teitler, Joan B

    2009-01-01

    A rapid, human on-site urine multidrug test was used to screen canine urine samples for the presence of five illegal drugs and drugs from three commonly abused drug classes. Each sample was sent to a toxicology laboratory for gas chromatography/mass spectrometry (GC/MS) validation. On-site test results and GC/MS assays confirmed that the human on-site test kit did identify barbiturates, opiates, benzodiazepines, and amphetamines/methamphetamines in urine from dogs that had received these common illicit drugs/drug classes either intravenously and/or orally. However, neither the on-site test kit nor the GC/MS individual assays for marijuana or methadone, a synthetic opiate, were effective in identifying marijuana and methadone in urine from dogs with suspected or known exposure. No index of suspicion was seen for exposure to phencyclidines or cocaine during the study period, and no exposures were indicated by the on-site test results. Overall, the test is a rapid, readily available, affordable, and useful complement to the veterinarian's clinical consideration and professional judgment.

  12. Pi-EEWS: a low cost prototype for on-site earthquake early warning system

    Science.gov (United States)

    Pazos, Antonio; Vera, Angel; Morgado, Arturo; Rioja, Carlos; Davila, Jose Martin; Cabieces, Roberto

    2017-04-01

    The Royal Spanish Navy Observatory (ROA), with the participation of the Cadiz University (UCA), have been developed the ALERTES-SC3 EEWS (regional approach) based on the SeisComP3 software package. This development has been done in the frame of the Spanish ALERT-ES (2011-2013) and ALERTES-RIM (2014-2016) projects, and now a days it is being tested in real time for south Iberia. Additionally, the ALERTES-SC3 system integrates an on-site EEWS software, developed by ROA-UCA, which is running for testing in real time in some seismic broad band stations of the WM network. Regional EEWS are not able to provide alerts in the area closet to the epicentre (blind zone), so a dense on-site EEWS is necessary. As it was mentioned, ALERTES-SC3 inludes the on-site software running on several WM stations but a more dense on-site stations are necessary to cover the blind zones. In order to densify this areas, inside of the "blind zones", a low cost on-site prototype "Pi-EEWS", based on a Raspberry Pi card and low cost acelerometers. In this work the main design ideas, the components and its capabilities will be shown.

  13. 77 FR 21588 - Hart and Cooley, Inc., A Subsidiary of Tomkins, PLC Including On-Site Leased Workers from...

    Science.gov (United States)

    2012-04-10

    ... Employment and Training Administration Hart and Cooley, Inc., A Subsidiary of Tomkins, PLC Including On- Site... subsidiary of Tomkins, PLC, including on-site leased workers from Reliable, Masiello Employment Services... workers from Hart and Cooley, Inc., a subsidiary of Tomkins, PLC, including on-site leased workers...

  14. 75 FR 11921 - Heritage Aviation, Ltd., Including On-Site Leased Workers From Global Technical Services and...

    Science.gov (United States)

    2010-03-12

    ... Employment and Training Administration Heritage Aviation, Ltd., Including On-Site Leased Workers From Global... workers of Heritage Aviation, including on-site leased workers from Heritage Aviation, Ltd, including on... leased from Global Inc., were employed on-site at the Grand Prairie, Texas location of Heritage...

  15. 75 FR 453 - FLSMidth, Inc., Cement Division, Product Engineering, Including On-Site Leased Workers of Aerotek...

    Science.gov (United States)

    2010-01-05

    ...., Cement Division, Product Engineering, Including On-Site Leased Workers of Aerotek Contract Engineering..., applicable to workers of FLSmidth, Inc., Cement Division, Product Engineering, including on-site leased...-site leased workers from Clarke Consulting, Inc. were also employed on-site at FLSmidth, Inc.,...

  16. Power Outages

    Science.gov (United States)

    ... Thunderstorms & Lightning Tornadoes Tsunamis Volcanoes Wildfires Main Content Power Outages This page provides basic safety tips and ... during and after a power outage. Before a Power Outage Build or restock your emergency preparedness kit , ...

  17. Wind Power

    OpenAIRE

    Makhalas, Kharsan Al; Alsehlli, Faisal

    2015-01-01

    This Bachelor thesis has been written at the Blekinge Institute of Technology. This thesis concentrates on the wind power and their components, also the large wind farm is studied. The electrical power is generated by using the power in wind to drive a wind turbine to produce mechanical power. This mechanical power can be converted into electrical power by using electrical induction generators. There are two types of the wind turbines, the horizontal axis and vertical axis wind turbine, where...

  18. On-site real-time evaluation of an air-conditioning direct-fired double-effect absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Torrella, E.; Larumbe, J.A. [Polytechnic University of Valencia, Department of Applied Thermodynamics, Camino de Vera 14, E-46022 Valencia (Spain); Sanchez, D.; Cabello, R.; Llopis, R. [Jaume I University, Department of Mechanical Engineering and Construction, Campus de Riu Sec s/n, E-12071 Castellon (Spain)

    2009-06-15

    This work presents a procedure for calculating the COP and heat transfer rates, based on on-site experimental temperature measurements, of a lithium-bromide/water direct-fired double-effect absorption chiller in reverse parallel flow configuration, running on natural gas. The chiller was equipped with a set of thermocouples which allowed measuring its working temperature levels through all its operating stages. The chiller analysed in this work is the central cooling system of the air-conditioning installation of the Principe Felipe Science Museum, located at the Valencia's City of Arts and Sciences (Spain). This installation is capable of providing a cooling capacity of 4.5 millions of kcal/h (5.2 MW), by means of three direct-fired double-effect absorption chillers. From the experimental measurements a calculation procedure, based on energy and mass balances, has been developed, which allows estimating the specific powers by unit of mass flow rate through the evaporator. From these power values the instantaneous COP of the chiller could be obtained. Additionally, the paper analyzes different aspects that were not possible to be considered and details the actions taken in order to take them into account. (author)

  19. Transient responses of phosphoric acid fuel cell power plant system. Ph.D. Thesis

    Science.gov (United States)

    Lu, Cheng-Yi

    1983-01-01

    An analytical and computerized study of the steady state and transient response of a phosphoric acid fuel cell (PAFC) system was completed. Parametric studies and sensitivity analyses of the PAFC system's operation were accomplished. Four non-linear dynamic models of the fuel cell stack, reformer, shift converters, and heat exchangers were developed based on nonhomogeneous non-linear partial differential equations, which include the material, component, energy balance, and electrochemical kinetic features. Due to a lack of experimental data for the dynamic response of the components only the steady state results were compared with data from other sources, indicating reasonably good agreement. A steady state simulation of the entire system was developed using, nonlinear ordinary differential equations. The finite difference method and trial-and-error procedures were used to obtain a solution. Using the model, a PAFC system, that was developed under NASA Grant, NCC3-17, was improved through the optimization of the heat exchanger network. Three types of cooling configurations for cell plates were evaluated to obtain the best current density and temperature distributions. The steady state solutions were used as the initial conditions in the dynamic model. The transient response of a simplified PAFC system, which included all of the major components, subjected to a load change was obtained. Due to the length of the computation time for the transient response calculations, analysis on a real-time computer was not possible. A simulation of the real-time calculations was developed on a batch type computer. The transient response characteristics are needed for the optimization of the design and control of the whole PAFC system. All of the models, procedures and simulations were programmed in Fortran and run on IBM 370 computers at Cleveland State University and the NASA Lewis Research Center.

  20. Pragmatic power

    CERN Document Server

    Eccles, William

    2008-01-01

    Pragmatic Power is focused on just three aspects of the AC electrical power system that supplies and moves the vast majority of electrical energy nearly everywhere in the world: three-phase power systems, transformers, and induction motors. The reader needs to have had an introduction to electrical circuits and AC power, although the text begins with a review of the basics of AC power. Balanced three-phase systems are studied by developing their single-phase equivalents. The study includes a look at how the cost of ""power"" is affected by reactive power and power factor. Transformers are cons

  1. Integrated airlift bioreactor system for on-site small wastewater treatment.

    Science.gov (United States)

    Chen, S L; Li, F; Qiao, Y; Yang, H G; Ding, F X

    2005-01-01

    An integrated airlift bioreactor system was developed, which mainly consists of a multi-stage loop reactor and a gas-liquid-solid separation baffle and possesses dual functions as bioreactor and settler. This integrated system was used for on-site treatment of industrial glycol wastewater in lab-scale. The strategy of gradually increasing practical wastewater concentration while maintaining the co-substrate glucose wastewater concentration helped to accelerate the microbial acclimation process. Investigation of microbial acclimation, operation parameters evaluation and microbial observation has demonstrated the economical and technical feasibility of this integrated airlift bioreactor system for on-site small industrial wastewater treatment.

  2. Study for highly functional resin (macroporous resin) superior in removing micro particles in PWR primary circuit: on-site test

    Energy Technology Data Exchange (ETDEWEB)

    Itou, A.; Kondo, K.; Kouzuma, Y., E-mail: ayumu_itou@kyuden.co.jp [Kyusyu Electric Power Co., Inc., Minami-ku, Fukuoka (Japan); Umehara, R.; Shimizu, Y., E-mail: Ruyji_Umehara@mhi.co.jp [Mitsubishi Heavy Industries, Ltd., Hyogo-ku, Kobe (Japan); Kogawa, N.; Nagamine, K., E-mail: nkogawa@ndc.hq.mhi.co.jp [Nuclear Development Corp., Tokaimura, Ibaraki (Japan)

    2010-07-01

    In Japanese PWR plants, efforts to remove particulate constituents containing radioactive cobalt which provides a source of radiation exposure, are needed. Performance evaluation study was conducted for macroporous resin which was said to possess excellent performance in removing particulate constituents and whose practical accomplishment at plants in USA was reported to be good. As one of the means for radiation exposure reduction in PWR, a study for application of crud removing resin to actual plant was executed by laboratory experiments using simulated crud (Fe{sub 3}O{sub 4} particle). In this study, following two mechanisms were demonstrated as the particle capturing mechanism of macroporous resin; physical trapping by fine pores on resin surface; electrical adsorption onto resin surface. In addition, in parallel to the study for application of macroporous resin to actual PWR plant, on-site study was planned to investigate the primary system water chemistry during various stages of actual plant operation and to research performance of particle capturing in detail. As the on-site study, column experiments, there water was let pass through the column, were planned for various operation stage (startup period, power operation period and shutdown period). A kind of conventional gel-type resin and three kinds of macroporous resin were examined for onsite tests. As to particulate capturing, basic knowledge regarding capturing efficiency and influence of water chemistry on capturing performance were ordered. Capturing performance of each resin tested became clear and was ordered by comparison. Effectiveness of macroporous resin with regard to crud removal in primary coolant was confirmed. (author)

  3. GMP-conformant on-site manufacturing of a CD133(+) stem cell product for cardiovascular regeneration.

    Science.gov (United States)

    Skorska, Anna; Müller, Paula; Gaebel, Ralf; Große, Jana; Lemcke, Heiko; Lux, Cornelia A; Bastian, Manuela; Hausburg, Frauke; Zarniko, Nicole; Bubritzki, Sandra; Ruch, Ulrike; Tiedemann, Gudrun; David, Robert; Steinhoff, Gustav

    2017-02-10

    CD133(+) stem cells represent a promising subpopulation for innovative cell-based therapies in cardiovascular regeneration. Several clinical trials have shown remarkable beneficial effects following their intramyocardial transplantation. Yet, the purification of CD133(+) stem cells is typically performed in centralized clean room facilities using semi-automatic manufacturing processes based on magnetic cell sorting (MACS®). However, this requires time-consuming and cost-intensive logistics. CD133(+) stem cells were purified from patient-derived sternal bone marrow using the recently developed automatic CliniMACS Prodigy® BM-133 System (Prodigy). The entire manufacturing process, as well as the subsequent quality control of the final cell product (CP), were realized on-site and in compliance with EU guidelines for Good Manufacturing Practice. The biological activity of automatically isolated CD133(+) cells was evaluated and compared to manually isolated CD133(+) cells via functional assays as well as immunofluorescence microscopy. In addition, the regenerative potential of purified stem cells was assessed 3 weeks after transplantation in immunodeficient mice which had been subjected to experimental myocardial infarction. We established for the first time an on-site manufacturing procedure for stem CPs intended for the treatment of ischemic heart diseases using an automatized system. On average, 0.88 × 10(6) viable CD133(+) cells with a mean log10 depletion of 3.23 ± 0.19 of non-target cells were isolated. Furthermore, we demonstrated that these automatically isolated cells bear proliferation and differentiation capacities comparable to manually isolated cells in vitro. Moreover, the automatically generated CP shows equal cardiac regeneration potential in vivo. Our results indicate that the Prodigy is a powerful system for automatic manufacturing of a CD133(+) CP within few hours. Compared to conventional manufacturing processes, future clinical

  4. Phosphoric acid fuel cell platinum use study

    Science.gov (United States)

    Lundblad, H. L.

    1983-01-01

    The U.S. Department of Energy is promoting the private development of phosphoric acid fuel cell (PAFC) power plants for terrestrial applications. Current PAFC technology utilizes platinum as catalysts in the power electrodes. The possible repercussions that the platinum demand of PAFC power plant commercialization will have on the worldwide supply and price of platinum from the outset of commercialization to the year 2000 are investigated. The platinum demand of PAFC commercialization is estimated by developing forecasts of platinum use per unit of generating capacity and penetration of PAFC power plants into the electric generation market. The ability of the platinum supply market to meet future demands is gauged by assessing the size of platinum reserves and the capability of platinum producers to extract, refine and market sufficient quantities of these reserves. The size and timing of platinum price shifts induced by the added demand of PAFC commercialization are investigated by several analytical methods. Estimates of these price shifts are then used to calculate the subsequent effects on PAFC power plant capital costs.

  5. 77 FR 59986 - General Motors Vehicle Manufacturing Including On-Site Leased Workers from Aerotek, Kelly...

    Science.gov (United States)

    2012-10-01

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration General Motors Vehicle Manufacturing Including On-Site Leased Workers from Aerotek, Kelly Services, Voith Industrial Services, Shreveport Ramp Services, Dana Holding Corporation, The Landing of GM, Filtration Services...

  6. 77 FR 62535 - General Motors Vehicle Manufacturing Including On-Site Leased Workers From Aerotek, Kelly...

    Science.gov (United States)

    2012-10-15

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration General Motors Vehicle Manufacturing Including On-Site Leased Workers From Aerotek, Kelly Services, Voith Industrial Services, Shreveport Ramp Services, Dana Holding Corporation, the Landing Of GM, Filtration Services...

  7. The interactive on-site inspection system: An information management system to support arms control inspections

    Energy Technology Data Exchange (ETDEWEB)

    DeLand, S.M.; Widney, T.W.; Horak, K.E.; Caudell, R.B.; Grose, E.M.

    1996-12-01

    The increasing use of on-site inspection (OSI) to meet the nation`s obligations with recently signed treaties requires the nation to manage a variety of inspection requirements. This document describes a prototype automated system to assist in the preparation and management of these inspections.

  8. 75 FR 76487 - Haldex Brake Corporation, Commercial Vehicle Systems, Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-08

    ...-Site Leased Workers of Johnston Integration Technologies, a Subsidiary of Johnston Companies, Iola, KS... company reports that workers leased from Johnston Integration Technologies, a subsidiary of Johnston... from Johnston Integration Technologies, a subsidiary of Johnston Companies working on-site at the...

  9. 2009 Melbourne metropolitan sewerage strategy: a portfolio of decentralised and on-site concept designs.

    Science.gov (United States)

    Brown, V; Jackson, D W; Khalifé, M

    2010-01-01

    The bulk and retail water companies of the greater Melbourne area are developing the 2009 Metropolitan Sewerage Strategy to provide sustainable sewerage services to 2060. The objective of the strategy is to establish long term principles and near term actions to produce a robust sewage management system for Melbourne. Melbourne's existing sewerage system is largely centralised and discharges to two major treatment plants. Several small satellite treatment plants service local urban areas generally more distant from the centralised system. Decentralised and on-site wastewater systems are options for future sewage management and could play a role in local recycling. A portfolio of 18 on-site and decentralised concept designs was developed, applicable to the full range of urban development types in Melbourne. The concepts can be used in evaluation of metropolitan system configurations as part of future integrated water cycle planning. The options included secondary and tertiary treatment systems incorporating re-use of water for non potable uses, urine separation, black and greywater separation and composting toilets. On-site and cluster treatment systems were analysed. Each option is described by its indicative capital and operating costs, energy use and water and nutrient balances. This paper summarises and compares the portfolio mix of decentralized and on-site options in Melbourne's context.

  10. 40 CFR 266.108 - Small quantity on-site burner exemption.

    Science.gov (United States)

    2010-07-01

    ...) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.108... burn hazardous waste in an on-site boiler or industrial furnace are exempt from the requirements of...

  11. 75 FR 35901 - On-Site Completion of Construction of Manufactured Homes

    Science.gov (United States)

    2010-06-23

    ... Manufactured Homes; Proposed Rule #0;#0;Federal Register / Vol. 75 , No. 120 / Wednesday, June 23, 2010... On-Site Completion of Construction of Manufactured Homes AGENCY: Office of the Assistant Secretary... establishing uniform procedures by which manufacturers could complete construction of their homes at the...

  12. Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran

    Science.gov (United States)

    Taghipour, Hassan; Alizadeh, Mina; Dehghanzadeh, Reza; Farshchian, Mohammad Reza; Ganbari, Mohammad; Shakerkhatibi, Mohammad

    2016-01-01

    Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment) was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests) indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative.

  13. On-Site Enzyme Production by Trichoderma asperellum for the Degradation of Duckweed

    DEFF Research Database (Denmark)

    Bech, Lasse; Herbst, Florian-Alexander; Grell, Morten Nedergaard

    2015-01-01

    The on-site production of cell wall degrading enzymes is an important strategy for the development of sustainable bio-refinery processes. This study concerns the optimization of production of plant cell wall-degrading enzymes produced by Trichoderma asperellum. A comparative secretome analysis...

  14. On-Site Enzyme Production by Trichoderma asperellum for the Degradation of Duckweed

    DEFF Research Database (Denmark)

    Bech, Lasse; Herbst, Florian-Alexander; Grell, Morten Nedergaard

    2015-01-01

    The on-site production of cell wall degrading enzymes is an important strategy for the development of sustainable bio-refinery processes. This study concerns the optimization of production of plant cell wall-degrading enzymes produced by Trichoderma asperellum. A comparative secretome analysis...

  15. 76 FR 14101 - Commercial Furniture Group, Inc., Including On-Site Leased Workers From Staffing Solutions...

    Science.gov (United States)

    2011-03-15

    ... commercial wood furniture. The Department's Notice was published in the Federal Register on May 28, 2010 (75... Employment and Training Administration Commercial Furniture Group, Inc., Including On-Site Leased Workers From Staffing Solutions; Morristown, TN; Commercial Furniture Group, Inc., Chicago, IL;...

  16. 78 FR 8586 - PEPSICO, Inc., Business & Information Solutions (BIS) Division Including On-Site Leased Workers...

    Science.gov (United States)

    2013-02-06

    ... Including On-Site Leased Workers From Procurestaff, Cognizant, Infosys, Wipro, and TCS; Plano, TX; PEPSICO... workers of PepsiCo, Inc., Business & Information Solutions (BIS) Division, Plano, Texas (PepsiCo-BIS-Plano... reviewed the certification for workers and former workers of PepsiCo-BIS-Plano. The Department has...

  17. 40 CFR 279.23 - On-site burning in space heaters.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false On-site burning in space heaters. 279... burning in space heaters. Generators may burn used oil in used oil-fired space heaters provided that: (a) The heater burns only used oil that the owner or operator generates or used oil received from...

  18. Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Hassan Taghipour

    2016-10-01

    Full Text Available Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative.

  19. 78 FR 54487 - Abbott Laboratories; Diagnostic-Hematology; Including On-Site Leased Workers From Manpower...

    Science.gov (United States)

    2013-09-04

    ... Workers From Manpower Service Group and ATR International; Santa Clara, California; Amended Certification..., Santa Clara, California. The Department's notice of determination was published in the Federal Register... from ATR International were employed on-site at the Santa Clara, California location of...

  20. Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran.

    Science.gov (United States)

    Taghipour, Hassan; Alizadeh, Mina; Dehghanzadeh, Reza; Farshchian, Mohammad Reza; Ganbari, Mohammad; Shakerkhatibi, Mohammad

    2016-01-01

    Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment) was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests) indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative.

  1. Large-scale tomo-PIV for on-site drag analysis in speed sports

    NARCIS (Netherlands)

    Terra, W.; Sciacchitano, A.; Scarano, F.

    2015-01-01

    Large-scale tomographic Particle Image Velocimetry is proposed as a tool for the on-site aerodynamic investigation in speed sports. The ring-of-fire concept is presented, which relies upon a tomographic PIV system used during the training of athletes in speed sports. The system consists of a short t

  2. 76 FR 72978 - Whirlpool Corporation Including On-Site Leased Workers From Career Solutions TEC Staffing...

    Science.gov (United States)

    2011-11-28

    ... Canteen, Fort Smith, AR; Amended Certification Regarding Eligibility To Apply for Worker Adjustment..., and Canteen were employed on-site at the Fort Smith, Arkansas location of Whirlpool Corporation. The... to include workers leased from IBM Corporation, TEK Systems, Penske Logistics, Eurest, and...

  3. Pathogen Treatment Guidance and Monitoring Approaches fro On-Site Non-Potable Water Reuse

    Science.gov (United States)

    On-site non-potable water reuse is increasingly used to augment water supplies, but traditional fecal indicator approaches for defining and monitoring exposure risks are limited when applied to these decentralized options. This session emphasizes risk-based modeling to define pat...

  4. Guidance for characterizing explosives contaminated soils: Sampling and selecting on-site analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Crockett, A.B. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Craig, H.D. [Environmental Protection Agency, Portland, OR (United States). Oregon Operations Office; Jenkins, T.F. [Army Cold Regions Research and Engineering Lab., Hanover, NH (United States); Sisk, W.E. [Army Environmental Center, Aberdeen Proving Grounds, MD (United States)

    1996-09-01

    A large number of defense-related sites are contaminated with elevated levels of secondary explosives. Levels of contamination range from barely detectable to levels above 10% that need special handling due to the detonation potential. Characterization of explosives-contaminated sites is particularly difficult due to the very heterogeneous distribution of contamination in the environment and within samples. To improve site characterization, several options exist including collecting more samples, providing on-site analytical data to help direct the investigation, compositing samples, improving homogenization of samples, and extracting larger samples. On-site analytical methods are essential to more economical and improved characterization. On-site methods might suffer in terms of precision and accuracy, but this is more than offset by the increased number of samples that can be run. While verification using a standard analytical procedure should be part of any quality assurance program, reducing the number of samples analyzed by the more expensive methods can result in significantly reduced costs. Often 70 to 90% of the soil samples analyzed during an explosives site investigation do not contain detectable levels of contamination. Two basic types of on-site analytical methods are in wide use for explosives in soil, calorimetric and immunoassay. Calorimetric methods generally detect broad classes of compounds such as nitroaromatics or nitramines, while immunoassay methods are more compound specific. Since TNT or RDX is usually present in explosive-contaminated soils, the use of procedures designed to detect only these or similar compounds can be very effective.

  5. Enhanced On-Site Waste Management of Plasterboard in Construction Works: A Case Study in Spain

    Directory of Open Access Journals (Sweden)

    Ana Jiménez-Rivero

    2017-03-01

    Full Text Available On-site management of construction waste commonly determines its destination. In the case of plasterboard (PB, on-site segregation becomes crucial for closed-loop recycling. However, PB is commonly mixed with other wastes in Spain. In this context, the involvement of stakeholders that can contribute to reversing this current situation is needed. This paper analyzes on-site waste management of PB in Spain through a pilot study of a construction site, with the main objective of identifying best practices to increase waste prevention, waste minimization, and the recyclability of the waste. On-site visits and structured interviews were conducted. The results show five management stages: PB distribution (I; PB installation (II; Construction waste storage at the installation area (III; PB waste segregation at the installation area (IV and PB waste transfer to the PB container and storage (V. The proposed practices refer to each stage and include the merging of Stages III and IV. This measure would avoid the mixing of waste fractions in Stage III, maximizing the recyclability of PB. In addition, two requisites for achieving enhanced management are analyzed: ‘Training and commitment’ and ‘fulfilling the requirements established by the current regulation’. The results show that foremen adopted a more pessimistic attitude than installers towards a joint commitment for waste management. Moreover, not all supervisors valued the importance of a site waste management plan, regulated by the Royal Decree 105/2008 in Spain.

  6. 75 FR 41895 - Whirlpool Corporation, Evansville Division, Including On-Site Leased Workers From Andrews...

    Science.gov (United States)

    2010-07-19

    ... Workers From Andrews International, Inc., M.H. Equipment, and Kenco Logistics Services, LLC, Evansville..., Evansville Division, including on-site leased workers from Andrews International, Inc., Kenco Logistics... notice was published in the Federal Register on March 5, 2010 (75 FR 10321). The notice was amended...

  7. 75 FR 63508 - Warner Chilcott Pharmaceuticals, Inc. Including On-Site Leased Workers From Adecco Engineering...

    Science.gov (United States)

    2010-10-15

    ... Employment and Training Administration Warner Chilcott Pharmaceuticals, Inc. Including On-Site Leased Workers... Pharmaceuticals, Inc., Norwich, New York. The notice was published in the Federal Register on September 23, 2010... of the subject firm. The workers were engaged in employment related to the supply of...

  8. On-site energy consumption and selected emissions at softwood sawmills in the southwestern United States

    Science.gov (United States)

    Dan Loeffler; Nathaniel Anderson; Todd A. Morgan; Colin B. Sorenson

    2016-01-01

    Presently there is a lack of information describing US southwestern energy consumption and emissions generated from the sawmilling industry. This article uses a mail survey of softwood sawmills in the states of Arizona, Colorado, and New Mexico to develop a profile of on-site energy consumption and selected emissions for the industry. Energy consumption is...

  9. Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-06-01

    Axillary ultrasonography (AUS) and fine-needle aspiration cytology (FNAC) can establish axillary lymph node status before surgery, although this technique is hampered by poor adequacy rates. To achieve consistently high rates of FNAC adequacy, rapid on-site evaluation (ROSE) of FNAC samples was introduced.

  10. Technology development for phosphoric acid fuel cell powerplant (phase 2). [on site integrated energy systems

    Science.gov (United States)

    Christner, L.

    1980-01-01

    Progress is reported in the development of material, cell components, and reformers for on site integrated energy systems. Internal resistance and contact resistance were improved. Dissolved gases (O2, N2, and CO2) were found to have no effect on the electrochemical corrosion of phenolic composites. Stack performance was increased by 100 mV over the average 1979 level.

  11. Utilization of Online Training for On-Site Clinical Supervisors: One University's Approach.

    Science.gov (United States)

    Getz, Hildy G.; Schnurman-Crook, Abrina

    2001-01-01

    The need to train on-site clinical supervisors often clashes with the practicality of time constraints of a variety of counseling professionals, as well as a significant geographical separation. This article is an overview of how one university developed online training to provide supervision training to clinical supervisors unable to attend live…

  12. Limitations of on-site dairy farm regulatory debits as milk quality predictors.

    Science.gov (United States)

    Borneman, Darand L; Stiegert, Kyle; Ingham, Steve

    2015-03-01

    In the United States, compliance with grade A raw fluid milk regulatory standards is assessed via laboratory milk quality testing and by on-site inspection of producers (farms). This study evaluated the correlation between on-site survey debits being marked and somatic cell count (SCC) or standard plate count (SPC) laboratory results for 1,301 Wisconsin grade A dairy farms in 2012. Debits recorded on the survey form were tested as predictors of laboratory results utilizing ordinary least squares regression to determine if results of the current method for on-site evaluation of grade A dairy farms accurately predict SCC and SPC test results. Such a correlation may indicate that current methods of on-site inspection serve the primary intended purpose of assuring availability of high-quality milk. A model for predicting SCC was estimated using ordinary least squares regression methods. Step-wise selected regressors of grouped debit items were able to predict SCC levels with some degree of accuracy (adjusted R2=0.1432). Specific debit items, seasonality, and farm size were the best predictors of SCC levels. The SPC data presented an analytical challenge because over 75% of the SPC observations were at or below a 25,000 cfu/mL threshold but were recorded by testing laboratories as at the threshold value. This classic censoring problem necessitated the use of a Tobit regression approach. Even with this approach, prediction of SPC values based on on-site survey criteria was much less successful (adjusted R2=0.034) and provided little support for the on-site survey system as a way to inform farmers about making improvements that would improve SPC. The lower level of correlation with SPC may indicate that factors affecting SPC are more varied and differ from those affecting SCC. Further, unobserved deficiencies in postmilking handling and storage sanitation could enhance bacterial growth and increase SPC, whereas postmilking sanitation will have no effect on SCC because

  13. A Comparison of Online versus On-site Training in Health Research Methodology: A Randomized Study

    Directory of Open Access Journals (Sweden)

    Kanchanaraksa Sukon

    2011-06-01

    Full Text Available Abstract Background Distance learning may be useful for building health research capacity. However, evidence that it can improve knowledge and skills in health research, particularly in resource-poor settings, is limited. We compared the impact and acceptability of teaching two distinct content areas, Biostatistics and Research Ethics, through either on-line distance learning format or traditional on-site training, in a randomized study in India. Our objective was to determine whether on-line courses in Biostatistics and Research Ethics could achieve similar improvements in knowledge, as traditional on-site, classroom-based courses. Methods Subjects: Volunteer Indian scientists were randomly assigned to one of two arms. Intervention: Students in Arm 1 attended a 3.5-day on-site course in Biostatistics and completed a 3.5-week on-line course in Research Ethics. Students in Arm 2 attended a 3.5-week on-line course in Biostatistics and 3.5-day on-site course in Research Ethics. For the two course formats, learning objectives, course contents and knowledge tests were identical. Main Outcome Measures: Improvement in knowledge immediately and 3-months after course completion, compared to baseline. Results Baseline characteristics were similar in both arms (n = 29 each. Median knowledge score for Biostatistics increased from a baseline of 49% to 64% (p Conclusion On-line and on-site training formats led to marked and similar improvements of knowledge in Biostatistics and Research Ethics. This, combined with logistical and cost advantages of on-line training, may make on-line courses particularly useful for expanding health research capacity in resource-limited settings.

  14. A comparison of online versus on-site training in health research methodology: a randomized study.

    Science.gov (United States)

    Aggarwal, Rakesh; Gupte, Nikhil; Kass, Nancy; Taylor, Holly; Ali, Joseph; Bhan, Anant; Aggarwal, Amita; Sisson, Stephen D; Kanchanaraksa, Sukon; McKenzie-White, Jane; McGready, John; Miotti, Paolo; Bollinger, Robert C

    2011-06-17

    Distance learning may be useful for building health research capacity. However, evidence that it can improve knowledge and skills in health research, particularly in resource-poor settings, is limited. We compared the impact and acceptability of teaching two distinct content areas, Biostatistics and Research Ethics, through either on-line distance learning format or traditional on-site training, in a randomized study in India. Our objective was to determine whether on-line courses in Biostatistics and Research Ethics could achieve similar improvements in knowledge, as traditional on-site, classroom-based courses. Volunteer Indian scientists were randomly assigned to one of two arms. Students in Arm 1 attended a 3.5-day on-site course in Biostatistics and completed a 3.5-week on-line course in Research Ethics. Students in Arm 2 attended a 3.5-week on-line course in Biostatistics and 3.5-day on-site course in Research Ethics. For the two course formats, learning objectives, course contents and knowledge tests were identical. Improvement in knowledge immediately and 3-months after course completion, compared to baseline. Baseline characteristics were similar in both arms (n = 29 each). Median knowledge score for Biostatistics increased from a baseline of 49% to 64% (p platforms for both Biostatistics (16% vs. 12%; p = 0.59) and Research Ethics (17% vs. 13%; p = 0.14). On-line and on-site training formats led to marked and similar improvements of knowledge in Biostatistics and Research Ethics. This, combined with logistical and cost advantages of on-line training, may make on-line courses particularly useful for expanding health research capacity in resource-limited settings.

  15. A positively charged silver nanowire membrane for rapid on-site swabbing extraction and detection of trace inorganic explosives using a portable Raman spectrometer

    Institute of Scientific and Technical Information of China (English)

    Yu-e Shi; Wenshou Wang; Jinhua Zhan

    2016-01-01

    The sensitive and on-site detection of inorganic explosives has raised serious concerns regarding public safety.However,high stability and non-volatility features currently limit their rapid on-site detection.Surface-enhanced Raman spectroscopy (SERS) is emerging as a powerful technique for the trace-level detection of different molecules.Plasmonic Ag nanowires were produced by a hydrothermal synthesis method using polyvinylpyrrolidone (PVP) as a negatively charged stabilizer.Here,we report a rapid detection method for inorganic explosives based on a simple surface swab with a positively charged diethyldithiocarbamate-modified Ag nanowire membrane coupled with SERS.This membrane,serving as an excellent SERS substrate with high uniformity,stability,and reusability,can capture both typical oxidizers in inorganic explosives and organic nitro-explosives,via electrostatic interaction.The detection level of perchlorates (ClO4-),chlorates (ClO3-),nitrates (NO3-),picric acid,and 2,4-dinitrophenol is as high as 2.0,1.7,0.1,45.8,and 36.6 ng,respectively.In addition,simulated typical inorganic explosives such as black powders,firecrackers,and match heads could also be detected.We believe that this membrane represents an attractive alternative for rapid on-site detection of inorganic explosives with high efficiency.

  16. Assessment of solar photocatalysis to purify on-site rinse waters from tractor cisterns used in grapevine pest control: field experimentation.

    Science.gov (United States)

    Pichat, P; Vannier, S; Dussaud, J; Rubis, J P

    2005-01-01

    The aim of this study was to assess in a vineyard the effect of purifying by solar photocatalysis the title rinse waters (currently most often rejected) in terms of efficacy and on-site practicality for the wine grower. The on-site, self-functioning, solar purifying unit included a corrugated-steel inclined plate of area S = 1 m2 onto which a TiO2-coated thin material had been slightly pressed, a tank, and an aquarium-type pump powered by a photovoltaic panel (appropriate for isolated locations). For a vineyard of area A = 0.15 km2, the rinse water (about 90 L) corresponding to each of four typical vine treatments in summer was analysed (major pesticides for each treatment, TOC, Microtox test and, in one case, BOD5) by independent laboratories, before and after purification for 8 days. The S/A ratio tested was found insufficient even if the photocatalytic treatment markedly improved the quality of the rinse waters. From the relatively low final organic content reached in one case, it is calculated that a three-time higher S/A ratio might suffice, but new trials are necessary to determine whether it is valid for other typical cases. Inferred contribution of inorganic ions to the post-photocatalytic treatment toxicity points to the need for an additional detoxification. These field experiments have also demonstrated that the purifying prototype is robust, and easy to install and use on site by the wine grower.

  17. Wind power in power systems

    CERN Document Server

    Ackermann, Thomas

    2012-01-01

    The second edition of the highly acclaimed Wind Power in Power Systems has been thoroughly revised and expanded to reflect the latest challenges associated with increasing wind power penetration levels. Since its first release, practical experiences with high wind power penetration levels have significantly increased. This book presents an overview of the lessons learned in integrating wind power into power systems and provides an outlook of the relevant issues and solutions to allow even higher wind power penetration levels. This includes the development of standard wind turbine sim

  18. Power Electronics

    DEFF Research Database (Denmark)

    Iov, Florin; Ciobotaru, Mihai; Blaabjerg, Frede

    2008-01-01

    energy at the end-user should also be set up. Deregulation of energy has in the past lowered the investment in larger power plants, which means the need for new electrical power sources will be high in the near future. Two major technologies will play important roles to solve the future problems. One...... is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most...... emerging renewable energy sources, wind energy, which by means of power electronics are changing from being a minor energy source to be acting as an important power source in the energy system. Power electronics is the enabling technology and the presentation will cover the development in wind turbine...

  19. Analysis of acoustic-seismic coupling behaviour for CTBT on-site inspection performance improvement

    Energy Technology Data Exchange (ETDEWEB)

    Liebsch, Mattes; Knoop, Jan-Frederik [Technische Univ. Dortmund (Germany)

    2013-07-01

    After teleseismic detection of a big underground explosion, during on-site inspections under the Comprehensive Nuclear Test-Ban Treaty (CTBT) weak seismic signals from aftershocks are to be detected. These, however, can be masked by soil vibrations which are caused by acoustic waves which couple to the ground. To analyse the coupling behaviour between acoustic waves and soil vibrations several experiments with different acoustic sources (helicopters, firecrackers, loudspeaker) were performed. Of special interest is the influence of surface waves, excited in a larger area around the sensor, which can superpose constructively at the position of the sensor and can increase the measured seismic signal. A better understanding of the acoustic-seismic coupling can be used to develop guidelines for seismic aftershock measurements, such as a suitable sensor setup, with the goal of reducing or even preventing disturbing signals to improve the performance of on-site inspections for the CTBT.

  20. Field sampling and selecting on-site analytical methods for explosives in soil

    Energy Technology Data Exchange (ETDEWEB)

    Crockett, A.B.; Craig, H.D.; Jenkins, T.F.; Sisk, W.E.

    1996-12-01

    A large number of defense-related sites are contaminated with elevated levels of secondary explosives. Levels of contamination range from barely detectable to levels above 10% that need special handling because of the detonation potential. Characterization of explosives-contaminated sites is particularly difficult because of the very heterogeneous distribution of contamination in the environment and within samples. To improve site characterization, several options exist including collecting more samples, providing on-site analytical data to help direct the investigation, compositing samples, improving homogenization of the samples, and extracting larger samples. This publication is intended to provide guidance to Remedial Project Managers regarding field sampling and on-site analytical methods for detecting and quantifying secondary explosive compounds in soils, and is not intended to include discussions of the safety issues associated with sites contaminated with explosive residues.

  1. Coexistence and competition of on-site and intersite Coulomb interactions in Mott-molecular-dimers

    Science.gov (United States)

    Juliano, R. C.; de Arruda, A. S.; Craco, L.

    2016-02-01

    We reveal the interplay between on-site (U) and intersite (V) Coulomb interactions in the extended two-site Hubbard model. Due to its atomic-like form quantum correlations intrinsic to Mott-molecular-dimers are exactly computed. Our results for physical quantities such as double occupancy and specific heat are consistent with those obtained for the one-band Hubbard model, suggesting that a two-site dimer model is able to capture the essential thermodynamic properties of strongly interacting electron systems. It is noted that intersite Coulomb interactions promote the formation of doublons, which compete with the spin-singlet state induced by the on-site Coulomb repulsion. Our results are expected to be relevant for understanding electronic and thermodynamical properties of interacting electrons in systems with strongly coupled magnetic atoms.

  2. On-Site or Off-Site Renewable Energy Supply Options?

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Heiselberg, Per; Jensen, Rasmus Lund;

    2012-01-01

    The concept of a Net Zero Energy Building (Net ZEB) encompasses two options of supplying renewable energy, which can offset energy use of a building, in particular on-site or off-site renewable energy supply. Currently, the on-site options are much more popular than the off-site; however, taking...... into consideration the limited area of roof and/or façade, primarily in the dense city areas, the Danish weather conditions, the growing interest and number of wind turbine co-ops, the off-site renewable energy supply options could become a meaningful solution for reaching ‘zero’ energy goal in the Danish context....... Therefore, this paper deploys the life cycle cost analysis and takes the private economy perspective to investigate the life cycle cost of different renewable energy supply options, and to identify the costoptimal combination between energy efficiency and renewable energy generation. The analysis includes...

  3. Rapid On-Site Formation of a Free-Standing Flexible Optical Link for Sensing Applications

    Directory of Open Access Journals (Sweden)

    Carlos Angulo Barrios

    2016-10-01

    Full Text Available An optical link, based on a conventional Scotch tape waveguide, for sensing applications requiring rapid on-site assembly is proposed and demonstrated. The flexible waveguide contains an integrated aluminum one-dimensional grating coupler that, when stuck on the radiative surface of a light emitting device, allows light to be coupled in and transmitted through the tape, whose tip end is, in turn, adhered onto the photosensitive surface of a photodetector. The (decoupling approaches exhibit high alignment tolerances that permit the formation of a free-standing flexible optical connection between surface-normal optoelectronic devices without the need of specialized equipment. As the first demonstration of a sensing application, the proposed optical link is easily configured as a cost-effective intensity-based refractometric sensor for liquid detection, which can be applicable to on-site quality and process control of, for example, beverages.

  4. Rapid On-Site Formation of a Free-Standing Flexible Optical Link for Sensing Applications

    Science.gov (United States)

    Barrios, Carlos Angulo

    2016-01-01

    An optical link, based on a conventional Scotch tape waveguide, for sensing applications requiring rapid on-site assembly is proposed and demonstrated. The flexible waveguide contains an integrated aluminum one-dimensional grating coupler that, when stuck on the radiative surface of a light emitting device, allows light to be coupled in and transmitted through the tape, whose tip end is, in turn, adhered onto the photosensitive surface of a photodetector. The (de)coupling approaches exhibit high alignment tolerances that permit the formation of a free-standing flexible optical connection between surface-normal optoelectronic devices without the need of specialized equipment. As the first demonstration of a sensing application, the proposed optical link is easily configured as a cost-effective intensity-based refractometric sensor for liquid detection, which can be applicable to on-site quality and process control of, for example, beverages. PMID:27782049

  5. Procurement Specifications Templates for On-Site Solar Photovoltaic: For Use in Developing Federal Solicitations

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-01-16

    With the increasing adaption of on-site renewable energy systems designed to feed site loads, there is a critical need to develop tools that allow the federal sector to become a mature and sophisticated consumer. This document is intended to reduce project development and operational risks while increasing the speed at which projects are completed; two necessary components to reach the scale required to meet mandates and achieve cost savings for taxpayers. This guide is intended to act as a living document where lessons learned from the increasing number of projects can be incorporated and provide guidance for efforts. While additional guides will be developed to cover other renewable technologies, this guide covers on-site solar photovoltaic systems with an emphasis on third-party designed, financed, owned, and operated systems.

  6. Electric Power

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ China Council for the Promotion of International Trade Electric Power Industry Office (CCPIT Electric Power), one of the pro-fessional industrial branches of China Council for the Promotion of International Trade (CCPIT), was established in 2006.

  7. Power Electronics

    DEFF Research Database (Denmark)

    Iov, Florin; Ciobotaru, Mihai; Blaabjerg, Frede

    2008-01-01

    is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most...... emerging renewable energy sources, wind energy, which by means of power electronics are changing from being a minor energy source to be acting as an important power source in the energy system. Power electronics is the enabling technology and the presentation will cover the development in wind turbine...... technology from kW to MW, discuss which power electronic solutions are most feasible and used today....

  8. Normative Power

    DEFF Research Database (Denmark)

    The social sciences have many different understandings of ‘normative power', but in European Union (EU) studies normative power has three particular meanings. The first meaning of normative power is its emphasis on normative theory, that is, how we judge and justify truth claims in social science....... The second meaning of normative power is as a form of power that is ideational rather than material or physical. The third meaning of normative power is as a characterisation of an ideal type of international actor. Empirical studies of normative forms of power have analysed both the causal and constitutive...... effects of EU relations with the world in areas ranging from inter-regional relations, through traditional diplomacy, to environmental politics. Research areas of particular interest include the study of the interplay between physical, material and normative forms of power, as well as the constitutive...

  9. Power Talk

    DEFF Research Database (Denmark)

    Angjelichinoski, Marko; Stefanovic, Cedomir; Popovski, Petar

    2016-01-01

    A standard way to realize communication in microgrid control is to use an external communication network, such as modems for wireless or power-line communication, whose implementation may be inefficient in terms of deployment cost, complexity, and system stability. In this chapter we present...... a communication solution, denoted as power talk, which is solely based on the use of the existing microgrid power equipment (i.e., power electronics and buses). The pivotal idea is to modulate information in the power-related parameters of the microgrid buses by use of the flexibility of power electronic...... interfaces. The focus of the chapter is on the design of power talk solutions for DC microgrids with droop control. Specifically, the chapter presents the power talk implementation through modification of the droop parameters of the primary control loop, and investigates the design of modulation schemes...

  10. Supervisors' perceptions of productivity of employees with preschool children in workplace on-site child care

    OpenAIRE

    Marickovich, Patricia Pesut

    1989-01-01

    Corporate leaders at Dominion Bankshares Corporation established an on-site child care facility at its operations center for its Roanoke, Virginia employees. The immediate supervisors of parents of children enrolled in the Dominion Child Development Center were surveyed to determine the factors they believed affected worker productivity and their perceptions of how employees' work habits had changed as a result of the opening of the child care center. A description of ...

  11. Feasibility Evaluation of an On-site Generator Network by the Cooperative Game Theory

    Science.gov (United States)

    Komiyama, Ryoichi; Hayashi, Taketo; Fujii, Yasumasa; Yamaji, Kenji

    On-site generator, such as CGS (cogeneration system), is allegedly considered to be an effective end-use energy system in order to accomplish primary energy conservation, CO2 emission mitigation and system cost reduction, which characteristics eventually improve the whole performance of an existing energy system for the future. Considering the drawback of installing an end-use CGS into the customer with small or middle scale floor space, however, it is difficult to achieve those distinctive features because the thermal-electricity ratio of CGS does not always be in agreement with that of customer energy demand. In order to overcome that matching deficiency, it is hence better to organize an on-site generator network based on mutual electricity and heating transmission. But focusing on some cogenerators underlying their behaviors on maximizing their own profits, this on-site network, which situation corresponds to a grand coalition, is not necessarily established because of each cogenerator’s motivation to form a partial coalition and acquire its own profit as much as possible. In this paper, we attempt to analyze the optimal operation of an on-site generator network and identify by applying the nucleolus of the cooperative game theory the optimal benefit allocation strategy in order for the cogenerators to construct the network. Regarding the installation site of this network, the center of Tokyo area is assumed, which locational information includes floor space and so forth through a GIS (geographic information system) database. The results from the nucleolus suggest that all districts should impartially obtain the benefit from organizing network for the purpose of jointly attaining the system total cost reduction.

  12. Training of medical teams on-site for individual and coordinated response in emergency management

    DEFF Research Database (Denmark)

    Andersen, Verner

    2003-01-01

    involved in the complete preparedness: fire brigade, police, medical team, civil defence, etc. All these modules will in the end be integrated on a common integration platform, either to a fully-fledged system covering all aspects of training for the complete preparedness, or for creating a dedicated...... system for specific training set-ups for specific groups of trainees. The first module completed as a commercial system, "Training of medical teams on site", will be presented....

  13. On-Site Surface Functionalization for Titanium Dental Implant with Nanotopography: Review and Outlook

    OpenAIRE

    Byung Gyu Kim; Seog-Jin Seo; Jung-Hwan Lee; Hae-Won Kim

    2016-01-01

    Titanium (Ti) has been the first choice of material for dental implant due to bonding ability to natural bone and great biocompatibility. Various types of surface roughness modification in nanoscale have been made as promising strategy for accelerating osseointegration of Ti dental implant. To have synergetic effect with nanotopography oriented favors in cell attachment, on-site surface functionalization with reproducibility of nanotopography is introduced as next strategy to further enhance ...

  14. Reliability of on-site greywater treatment systems in Mediterranean and arid environments - a case study.

    Science.gov (United States)

    Alfiya, Y; Gross, A; Sklarz, M; Friedler, E

    2013-01-01

    On-site greywater (GW) treatment and reuse is gaining popularity. However, a main point of concern is that inadequate treatment of such water may lead to negative environmental and health effects. Maintenance of single-family home GW systems is usually performed by home owners with limited professional support. Therefore, unless GW systems are reliable, environmental and public health might be compromised. This study is aimed at investigating the reliability of on-site recirculated vertical flow constructed wetlands (RVFCW) in 20 single-family homes. In order to ensure reliability, the failure-tree approach was adopted during the design and construction of the systems. The performance of the systems was monitored for 1.5 years, by evaluating treated GW flow and quality, and by recording all malfunctions and maintenance work. Only 39 failures occurred during this period, of which four caused irrigation with impaired quality GW, while the rest led to no irrigation. The mean time between failures (MTBF) was 305 days; two out of the 20 systems suffered from seven malfunctions (each), while nine systems did not fail at all. Thus, it can be postulated that if on-site GW treatment systems are designed with the right controls, and if scheduled (basic and relatively infrequent) maintenance is performed, GW reuse can be safe to the environment and human health.

  15. Membrane preconcentration of iron in seawater samples and on-site determination in spectrophotometry

    Institute of Scientific and Technical Information of China (English)

    PENG Yuanzhen; YUAN Dongxing; HUANG Yongming; JIANG Tao; LIU Baomin

    2012-01-01

    A novel method for on-site determination of trace iron was developed using membrane preconcentration and spectrophotometric detection.Fe(Ⅱ)-ferrozine complex was reacted with cetyltrimethylammonium bromide (CTAB) to form a Fe(Ⅱ)-ferrozine-CTAB paired compound,which was collected on a membrane by filtration under vacuum.The membrane was immersed in 2 mL of ethanol-nitric acid and the absorbance of the solution measured for quantitative analysis.Various factors affecting the iron collection and determination were investigated.With different sample preconcentration volumes,the range of determination was broadened to 0.5-120 μg/L.The detection limit of this method reached 0.19 μg/L and the recoveries were between 97.2 and 109% when the concentration enrichment was about 45.The relative standard deviation (n =7) was 1.9% for samples containing 10 μg/L Fe.Twelve seawater samples were analyzed on-site using the proposed method,and two were also analyzed in inductively coupled plasma mass spectrometry.No significant difference was shown between the two methods by the Student's t-test.The method has also been used on-site for iron enrichment experiments with phytoplankton and concluded to be simple,accurate and inexpensive.

  16. Assessment of On-site sanitation system on local groundwater regime in an alluvial aquifer

    Science.gov (United States)

    Quamar, Rafat; Jangam, C.; Veligeti, J.; Chintalapudi, P.; Janipella, R.

    2017-06-01

    The present study is an attempt to study the impact of the On-site sanitation system on the groundwater sources in its vicinity. The study has been undertaken in the Agra city of Yamuna sub-basin. In this context, sampling sites (3 nos) namely Pandav Nagar, Ayodhya Kunj and Laxmi Nagar were selected for sampling. The groundwater samples were analyzed for major cations, anions and faecal coliform. Critical parameters namely chloride, nitrate and Faecal coliform were considered to assess the impact of the On-site sanitation systems. The analytical results shown that except for chloride, most of the samples exceeded the Bureau of Indian Standard limits for drinking water for all the other analyzed parameters, i.e., nitrate and faecal coliform in the first two sites. In Laxmi Nagar, except for faecal coliform, all the samples are below the BIS limits. In all the three sites, faecal coliform was found in majority of the samples. A comparison of present study indicates that the contamination of groundwater in alluvial setting is less as compared to hard rock where On-site sanitation systems have been implemented.

  17. On-site analysis of heavy metal contaminated areas by means of total reflection X-ray fluorescence analysis (TXRF)

    Science.gov (United States)

    Stosnach, Hagen

    2006-11-01

    In this paper the possibilities and restriction for applying the low power TXRF spectrometer PicoTAX for the one-site analysis of heavy metal contaminated soils and sediments are evaluated. Basis for this evaluation is the Superfund Innovative Technology Evaluation (SITE) program, conducted by the U.S. Environmental Protection Protection Agency (US EPA). During a measurement campaign, performed under realistic conditions, 320 soil and sediment samples were analyzed. The task was the fast analysis of the main target elements antimony, arsenic, cadmium, chromium, copper, iron, lead, mercury, nickel, selenium, silver, vanadium, and zinc. These elements were present in wide ranging concentrations. Out of a set of seven primary and five secondary objectives the method detection limits, accuracy and precision of the TXRF measurements are discussed. In addition to the on-site measurements, the application of TXRF analysis for the analysis of soil- and sediment samples after complete microwave assisted acid digestion is reported. Recent instrument improvements have distinctly increased the quality of measurement results. A detailed description of these new developments and new measurement results are discussed

  18. 76 FR 27365 - West, A Thomson Reuters Business, Thomson Reuters Legal Division, Including On-Site Leased...

    Science.gov (United States)

    2011-05-11

    ..., Including On-Site Leased Workers From ADECCO, Albuquerque, NM; Notice of Affirmative Determination Regarding... former workers of West, A Thomson Reuters Business, Thomson Reuters Legal Division, Albuquerque,...

  19. Department of Energy's High Flux Beam Reactor (HFBR), September 15--19, 1980: An independent on-site safety review

    Energy Technology Data Exchange (ETDEWEB)

    1981-02-01

    The intent of this on-site safety review was to make a broad management assessment of HFBR operations, rather than conduct a detailed in-depth audit. The result of the review should only be considered as having identified trends or indications. The Team's observations and recommendations for the most part are based upon licensed reactor facility practices used to meet industry standards. These standards form the basis for many of the comments in this report. The Team believes that a uniform minimum standard of performance should be achieved in the operation of DOE reactors. In order to assure that this is accomplished, clear standards are necessary. Consistent with the past AEC and ERDA policy, the team has used the standards of the commercial nuclear power industry. It is recognized that this approach is conservative in that the HFBR reactor has a significantly greater degree of inherent safety (low pressure, temperature, power, etc.) than a licensed reactor.

  20. ALERTES-SC3 Early Warning System prototype for South Iberian Peninsula: on-site approach.

    Science.gov (United States)

    Pazos, Antonio; Lopez de Mesa, Mireya; Gallego Carrasco, Javier; Martín Davila, José; Rioja del Rio, Carlos; Morgado, Arturo; Vera, Angel; Ciberia, Angel; Cabieces, Roberto; Strollo, Angelo; Hanka, Winfried; Carranza, Marta

    2016-04-01

    In recent years several Earthquake Early Warning Systems (EEWS) have been developed for different parts of the world. The area between SW Cape St. Vicente and the Strait of Gibraltar is one of the most seismically active zones in the Ibero-Maghrebian region, with predominantly moderate and superficial seismicity, but also big events with associated tsunamis are well documented in the area, like the 1755 Lisbon earthquake. In the frame of the ALERT-ES (2011-2013) and ALERTES-RIM (2014-2016) Spanish projects, the ALERTES-SC3 EEWS, regional approach, prototype has been developed at the Royal Spanish Navy Observatory (ROA) and is being tested in near real time for south Iberia. This prototype, based on the SeisComP3 software package, is largely based on algorithms derived from the analysis of the first seconds of the P wave records. Calculation of several parameters are carried out, mainly the characteristic period (τc) and the displacement peak (Pd), but also the velocity peak (Pv), the maximum period (τPmáx), among others. In order to warm the areas closest to the hypocentre, places located inside the "blind zone", a on-site EEWS has also been developed by ROA and integrated in the ALERTES-SC3 prototype. From the on-site approach, a warm level is declared from one station as a function of the estimated characteristic period (τc) and the displacement Peak (Pd), although the earthquake location and therefore the lead time available remains unknown. This on-site EEWS is being tested in several Western Mediterranean net (WM) stations as ARNO (Arenosillo, Huelva,Spain) or CHAS (Chafarinas island, North Africa, Spain). Also an on-site low cost station is being developed based in low cost accelerometers. In this work the current state of the on-site EEWS developed, its integration in the ALERTES-SC3 EEWS system and the low cost seismic stations are shown.

  1. Flower power; Flower-Power

    Energy Technology Data Exchange (ETDEWEB)

    Wiedemann, Karsten

    2010-08-15

    Scientists of Kassel university developed a concept for producing heat and electric power from grassland biomass. This strategy of decentral heat and power supply will also contribute to conservation goals. (orig.)

  2. Stockholm Power Tech. Power systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The proceedings from this symposium is presented in six volumes: Invited speakers` sessions; Power systems; Power electronics; High-voltage technology; Electrical machines and drives; and Information and control systems. This report covers the power systems volume. Separate abstracts have been prepared for 141 of the 145 papers in this volume

  3. Molten Carbonate and Phosphoric Acid Stationary Fuel Cells: Overview and Gap Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Remick, R.; Wheeler, D.

    2010-09-01

    This report describes the technical and cost gap analysis performed to identify pathways for reducing the costs of molten carbonate fuel cell (MCFC) and phosphoric acid fuel cell (PAFC) stationary fuel cell power plants.

  4. 76 FR 35025 - Nokia, Inc.; a Subsidiary of Nokia Group; Including On-Site Leased Workers From ATC Logistics and...

    Science.gov (United States)

    2011-06-15

    ... Employment and Training Administration Nokia, Inc.; a Subsidiary of Nokia Group; Including On-Site Leased... to Apply for Worker Adjustment Assistance on February 15, 2011, applicable to workers of Nokia, Inc., a subsidiary of Nokia Group, including on-site leased workers from ATC Logistics and...

  5. 77 FR 3499 - Sony Electronics, Inc., Including On-Site Leased Workers From Selectremedy Park Ridge, NJ...

    Science.gov (United States)

    2012-01-24

    ...] Sony Electronics, Inc., Including On-Site Leased Workers From Selectremedy Park Ridge, NJ; Amended... of Sony Electronics, Inc., SEL Headquarters, including on-site leased workers of SelectRemedy, StaffMark, and Payrolling.com , San Diego, California (TA-W-71,501); Sony Electronics, Inc., including...

  6. 76 FR 16447 - ETHICON, a Subsidiary of Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary...

    Science.gov (United States)

    2011-03-23

    ... Employment and Training Administration ETHICON, a Subsidiary of Johnson & Johnson Including On-Site Leased... Johnson & Johnson, including on-site leased workers from Kelly Temporary Services, San Angelo, Texas. The... certification of eligibility to apply for adjustment assistance was issued for all workers of ETHICON, A Johnson...

  7. 75 FR 11919 - Smith and Nephew, Inc., Wound Management-Largo Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-03-12

    ... Employment and Training Administration Smith and Nephew, Inc., Wound Management-Largo Division, Including On... workers of Smith and Nephew, Inc., Wound Management-Largo Division, Largo, Florida, including on-site... were employed on-site at the Largo, Florida location of Smith and Nephew, Inc., Wound...

  8. 75 FR 76038 - Zach System Corporation a Subdivision of Zambon Company, SPA Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-07

    ... On-Site Leased Workers of Turner Industries and Go Johnson, La Porte, TX; Amended Certification... Corporation, a subdivision of Zach System SPA, La Porte, Texas, including on-site leased workers from Turner Industries and Go Johnson, La Porte, Texas. The Department's notice of determination was published in...

  9. 78 FR 66779 - CTS Automotive LLC, a Subsidiary of CTS Corporation Including On-Site Leased Workers From Metro...

    Science.gov (United States)

    2013-11-06

    ... Employment and Training Administration CTS Automotive LLC, a Subsidiary of CTS Corporation Including On- Site... for Worker Adjustment Assistance on September 5, 2013, applicable to workers of CTS Automotive LLC, a subsidiary of CTS Corporation, including on-site leased workers from Metro Staff, Inc., and Aerotek,...

  10. 77 FR 12081 - Comscope, Inc., Catawba Facility, A Subsidiary of the Carlyle Group Including On-Site Leased...

    Science.gov (United States)

    2012-02-28

    ... Carolina. The workers are engaged in activities related to the production of coaxial cable and coax products for the cable television industry. The notice was published in the Federal Register on October 26... Including On-Site Leased Workers From Staffmasters, Including On- Site Workers from Cable Transport,...

  11. 40 CFR 262.212 - Making the hazardous waste determination at an on-site interim status or permitted treatment...

    Science.gov (United States)

    2010-07-01

    ....212 Making the hazardous waste determination at an on-site interim status or permitted treatment... hazardous waste permit or interim status as soon as it arrives in the on-site treatment, storage or disposal... permitted treatment, storage or disposal facility. (e) If the unwanted material is a hazardous waste, the...

  12. 76 FR 29274 - Superior Technical Resources and Bestway, Inc., Leased Workers Working On-Site at OSRAM Sylvania...

    Science.gov (United States)

    2011-05-20

    ... Employment and Training Administration Superior Technical Resources and Bestway, Inc., Leased Workers Working..., applicable to workers of Superior Technical Resources, leased workers working on-site at OSRAM Sylvania... workers of Superior Technical Resources and Bestway, Inc. working on-site at OSRAM Sylvania, Consumer...

  13. 75 FR 45158 - Holcim (US) Inc. Corporate Division Including On-Site Leased Workers From Manpower, Office Team...

    Science.gov (United States)

    2010-08-02

    ... Employment and Training Administration Holcim (US) Inc. Corporate Division Including On-Site Leased Workers... to Apply for Worker Adjustment Assistance on May 20, 2010, applicable to workers of Holcim (US) Inc... Services were employed on-site at the Dundee, Michigan location of Holcim (US) Inc., Corporate...

  14. 75 FR 38128 - Ceva Freight, LLC, Dell Logistics Division, Including On-Site Leased Workers From Prologistix and...

    Science.gov (United States)

    2010-07-01

    ... Employment and Training Administration Ceva Freight, LLC, Dell Logistics Division, Including On-Site Leased..., LLC, Dell Logistics Division, including on-site leased workers from Prologistix, Winston-Salem, North..., Dell Logistics Division. The Department has determined that these workers were sufficiently under...

  15. 76 FR 73684 - Tiger Drylac USA, Inc., Including On-Site Leased Workers From Berks and Beyond Employment...

    Science.gov (United States)

    2011-11-29

    ... Employment and Training Administration Tiger Drylac USA, Inc., Including On-Site Leased Workers From Berks... Adjustment Assistance on October 19, 2011, applicable to workers of Tiger Drylac USA, Inc., Reading.../Robert Half International were employed on- site at the Reading, Pennsylvania location of Tiger...

  16. 75 FR 41522 - Novell, Inc., Including On-Site Leased Workers From Affiliated Computer Services, Inc., (ACS...

    Science.gov (United States)

    2010-07-16

    ... Computer Services, Inc., (ACS), Provo, UT; Amended Certification Regarding Eligibility To Apply for Worker... reports that workers leased from Affiliated Computer Services, Inc., (ACS) were employed on-site at the...., (ACS) working on-site at the Provo, Utah location of Novell, Inc. The amended notice applicable to...

  17. 77 FR 75447 - Worley Parsons, Accounts Payable, a Subsidiary of Worley Parsons Corporation, Including On-Site...

    Science.gov (United States)

    2012-12-20

    ... Employment and Training Administration Worley Parsons, Accounts Payable, a Subsidiary of Worley Parsons...; Worley Parsons, Accounts Payable, a Subsidiary of Worley Parsons Corporation, Including On-Site Leased..., Accounts Payable, a subsidiary of Worley Parsons Corporation, including on-site leased workers from...

  18. 77 FR 3499 - FCI USA, LLC Corporate Administrative Division Including On-Site Leased Workers From JFC...

    Science.gov (United States)

    2012-01-24

    ... Employment and Training Administration FCI USA, LLC Corporate Administrative Division Including On-Site Leased Workers From JFC Including Teleworkers Located Throughout the United States Reporting to Etters..., applicable to workers of FCI USA, LLC, Corporate Administrative Division, including on-site leased...

  19. 75 FR 20386 - Trane a Subsidiary of Ingersoll Rand Including On-Site Leased Workers From Aerotek, Express...

    Science.gov (United States)

    2010-04-19

    ... Employment and Training Administration Trane a Subsidiary of Ingersoll Rand Including On-Site Leased Workers..., 2010, applicable to workers of Trane, a subsidiary of Ingersoll Rand, including on-site leased workers... subsidiary of Ingersoll Rand. The Department has determined that these workers were sufficiently under...

  20. 75 FR 26793 - Beam Global Spirits & Wine, Including On-Site Leased Workers from Adecco, St. Elizabeth Business...

    Science.gov (United States)

    2010-05-12

    ... Global Spirits & Wine, Including On-Site Leased Workers from Adecco, St. Elizabeth Business Health... Assistance on March 26, 2010, applicable to workers of Beam Global Spirits & Wine, including on-site leased... company reports that workers leased from St. Elizabeth Business Health, Guardsmark, and Lab Support...

  1. 76 FR 45879 - Cinram Manufacturing, LLC, a Subsidiary of Cinram International, Including On-Site Leased Workers...

    Science.gov (United States)

    2011-08-01

    ..., Including On-Site Leased Workers From OneSource Staffing Solutions, Canteen, Division of Compass Group and... Canteen, a division of Compass Group. The Department's amended Notice was published in the Federal... Cinram International, including on-site leased workers from OneSource Staffing Solutions, Canteen,...

  2. 76 FR 13668 - Cinram Manufacturing, LLC, a Subsidiary of Cinram International, Including On-Site Leased Workers...

    Science.gov (United States)

    2011-03-14

    ..., Including On-Site Leased Workers From Onesource Staffing Solutions and Canteen, Division of Compass Group... of the subject firm. The company reports that workers leased from Canteen, a division of Compass... certification to include workers leased from Canteen, a division of Compass Group working on-site at...

  3. 75 FR 69470 - JL French Automotive Castings, LLC, Including On-Site Leased Workers From Labor Ready and Seek...

    Science.gov (United States)

    2010-11-12

    ... Employment and Training Administration JL French Automotive Castings, LLC, Including On-Site Leased Workers... Worker Adjustment Assistance on November 4, 2009, applicable to workers of JL French Automotive Castings... workers leased from Seek Staffing, were employed on-site at the Sheboygan, Wisconsin location of JL...

  4. 77 FR 6587 - PHB Die Casting a Subsidiary of PHB, Inc., Including On-Site Leased Workers From Career Concepts...

    Science.gov (United States)

    2012-02-08

    ... Workers From Career Concepts and Volt Services, Including a Contract Worker From Burns Industrial Group... subsidiary of PHB, Inc., including on-site leased workers from Career Concepts and Volt Services, Fairview... Casting, a subsidiary of PHB, Inc., Fairview, Pennsylvania, including on-site leased workers from...

  5. 75 FR 21663 - Maysteel, LLC Including On-Site Leased Workers From Staff One, Badger Tech, Boyd Hunter, Seek...

    Science.gov (United States)

    2010-04-26

    ... Tech, Boyd Hunter, Seek, QPS, and Service First, Menomonee Falls, WI; Amended Certification Regarding..., including on-site leased workers from Staff One, Badger Tech, Boyd Hunter, Seek, and QPS, Menomonee Falls... Maysteel, LLC, including on-site leased workers from Staff One, Badger Tech, Boyd Hunter, Seek, QPS,...

  6. 76 FR 79221 - Android Industries Belvidere, LLC, Including On-Site Leased Workers From QPS Employment Group...

    Science.gov (United States)

    2011-12-21

    ... Employment and Training Administration Android Industries Belvidere, LLC, Including On-Site Leased Workers... Android Industries Belvidere, LLC, including on-site leased workers from QPS Employment Group and Spherion... Android Industries Belvidere, LLC. The Department has determined that these workers were sufficiently...

  7. 75 FR 34180 - Paris Accessories, Inc., Including On-Site Leased Workers From Job Connections, New Smithsville...

    Science.gov (United States)

    2010-06-16

    ... Register on April 23, 2010 (75 FR 21363). In the request for reconsideration, the petitioner stated that... Employment and Training Administration Paris Accessories, Inc., Including On-Site Leased Workers From Job... determine that workers of Paris Accessories, Inc., New Smithsville, Pennsylvania, including on-site...

  8. Field demonstration of on-site analytical methods for TNT and RDX in ground water

    Energy Technology Data Exchange (ETDEWEB)

    Craig, H. [Environmental Protection Agency Region 10, Portland, OR (United States); Ferguson, G.; Markos, A. [Black and Veatch Special Projects Corp., Tacoma, WA (United States); Kusterbeck, A.; Shriver-Lake, L. [Naval Research Lab., Washington, DC (United States). Center for Bio/Molecular Science and Engineering; Jenkins, T.; Thorne, P. [Army Corps of Engineers, Hanover, NH (United States). Cold Regions Research and Engineering Lab.

    1996-12-31

    A field demonstration was conducted to assess the performance of eight commercially-available and emerging colorimetric, immunoassay, and biosensor on-site analytical methods for explosives 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in ground water and leachate at the Umatilla Army Depot Activity, Hermiston, Oregon and US Naval Submarine Base, Bangor, Washington, Superfund sites. Ground water samples were analyzed by each of the on-site methods and results compared to laboratory analysis using high performance liquid chromatography (HPLC) with EPA SW-846 Method 8330. The commercial methods evaluated include the EnSys, Inc., TNT and RDX colorimetric test kits (EPA SW-846 Methods 8515 and 8510) with a solid phase extraction (SPE) step, the DTECH/EM Science TNT and RDX immunoassay test kits (EPA SW-846 Methods 4050 and 4051), and the Ohmicron TNT immunoassay test kit. The emerging methods tested include the antibody-based Naval Research Laboratory (NRL) Continuous Flow Immunosensor (CFI) for TNT and RDX, and the Fiber Optic Biosensor (FOB) for TNT. Accuracy of the on-site methods were evaluated using linear regression analysis and relative percent difference (RPD) comparison criteria. Over the range of conditions tested, the colorimetric methods for TNT and RDX showed the highest accuracy of the emerging methods for TNT and RDX. The colorimetric method was selected for routine ground water monitoring at the Umatilla site, and further field testing on the NRL CFI and FOB biosensors will continue at both Superfund sites.

  9. Solitary heat waves in nonlinear lattices with squared on-site potential

    Indian Academy of Sciences (India)

    Rovinita Perseus; M M Latha

    2013-06-01

    A model Hamiltonian is proposed for heat conduction in a nonlinear lattice with squared on-site potential using the second quantized operators and averaging the same using a suitable wave function, equations are derived in discrete form for the field amplitude and the properties of heat transfer are examined theoretically. Numerical analysis shows that the propagation of heat is in the form of solitons. Furthermore, a systemized version of tanh method is carried out to extract solutions for the resulting nonlinear equations in the continuum case and the effect of inhomogeneity is studied for different temperatures.

  10. Estimations of On-site Directional Wave Spectra from Measured Ship Responses

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2006-01-01

    include an quivalence of energy in the governing equations and, as regards the parametric concept, a frequency dependent spreading of the waves is introduced. The paper includes an extensive analysis of full-scale measurements for which the directional wave spectra are estimated by the two ship response......In general, two main concepts can be applied to estimate the on-site directional wave spectrum on the basis of ship response measurements: 1) a parametric method which assumes the wave spectrum to be composed by parameterised wave spectra, or 2) a non-parametric method where the directional wave...

  11. The risk analysis of dust electrostatic based on on-site survey of polypropylene plant

    Science.gov (United States)

    Wu, Xiumin; He, Mingjun; Yu, Haibo

    2013-03-01

    The dust electrostatic explosion accidents in polypropylene plant are mainly caused by the interaction of combustible gas, dust and static electricity. This paper analyses the key parts easy to produce dust and the risks of dust electrostatic by on-site survey of polypropylene plant, and proposes corresponding safety protection measures. The analysis results indicate that any careless mistakes and deviation in every step of process control may lead to electrostatic explosion in the silo. And if the equipment has some inherent defects and there are some careless mistakes in the process control, it will be easier to cause dust electrostatic explosion accidents.

  12. Estimations of On-site Directional Wave Spectra from Measured Ship Responses

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2006-01-01

    include an quivalence of energy in the governing equations and, as regards the parametric concept, a frequency dependent spreading of the waves is introduced. The paper includes an extensive analysis of full-scale measurements for which the directional wave spectra are estimated by the two ship response......In general, two main concepts can be applied to estimate the on-site directional wave spectrum on the basis of ship response measurements: 1) a parametric method which assumes the wave spectrum to be composed by parameterised wave spectra, or 2) a non-parametric method where the directional wave...

  13. On-site comprehensive analysis of explosives using HPLC-UV-PAED

    Science.gov (United States)

    Marple, Ronita L.; LaCourse, William R.

    2004-03-01

    High-performance liquid chromatography with ultra violet and photo-assisted electrochemical detection (HPLC-UV-PAED) has been developed for the sensitive and selective detection of explosives in ground water and soil extracts. Fractionation and preconcentration of explosives is accomplished with on-line solid phase extraction (SPE), which minimizes sample pretreatment and enables faster and more accurate on-site assessment of a contaminated site. Detection limits are equivalent or superior (i.e., organic nitro compounds. Soil samples are extracted using pressurized fluid extraction (PFE), and this technique is automatable, field-compatible, and environmentally friendly, adding to the overall efficiency of the methodology.

  14. Feasibility of on-site bioremediation of loam soil contaminated by diesel oil.

    Science.gov (United States)

    Rubin, H; Narkis, N

    2001-09-01

    This study originated from an accidental event of diesel oil contamination in a loam soil area of 7,000 m2. Approximately a volume of 1,300 m3 of diesel oil was released into the environment. Reclamation of the contaminated soil by on-site bioremediation was selected as the most appropriate treatment method. A major concern was associated with the nature of the local loam soil. Loam has a very low hydraulic conductivity and very quickly becomes impermeable after its contact with water. The bioremediation approach incorporated excavation of the contaminated soil, mixing it with an agent, which increased its permeability. Following this preliminary treatment came the construction of bioreactors as a suitable environment of nutrients, moisture, dissolved oxygen, and enriched culture of microorganisms, which enabled breakdown of the diesel oil. This case study indicated that the target of 99% of diesel oil clean up could be achieved by using the technology of on-site bioremediation. The selected treatment method was found to be technologically and economically feasible. However, some improvement in the application of the basic treatment approach might increase the bioremediation efficiency.

  15. Waste of Felling and On-Site Production of Teak Squarewood of the Community Forest

    Directory of Open Access Journals (Sweden)

    Ahmad Budiaman

    2012-12-01

    Full Text Available Major suppliers of teak wood for the raw material of furniture industry in Indonesia are Perum Perhutani, community forests, and private forests.  Community teak forest management produce roundwood or squarewood, in which squarewood is produced on the felling site by the use of chainsaw after felling and bucking activities. Utilization of teak wood from community forest has been practiced for decades, however information on the extent of utilization and the quantity of wood waste have not been published to a greater extent. The present research was intended to determine and analyze the extent of utilization and teak wood waste produced from felling and bucking, and on-site squarewood production of community forests.  Quantification of wood waste from felling and bucking was based on the whole tree method, while that of squarewood production was based on the percentage of yield. It was found that the quantity of teak felling and bucking wood waste in community forest was reaching 28% of felled wood volume that consisted of branch and twig (46.15%, upper trunk (30.77%, short cut off (15.38%, and stumps (7.69%. The largest part of the wood waste of teak felling and bucking satisfied the requirement as raw material of wood working industry according to Indonesian National Standard. On-site production of squarewood increased the quantity of wood waste in the forests (in the form of slabs and sawdust.Keywords: wood waste, felling, bucking, squarewood, community forest

  16. Nitrogen removal pathway of anaerobic ammonium oxidation in on-site aged refuse bioreactor.

    Science.gov (United States)

    Wang, Chao; Zhao, Youcai; Xie, Bing; Peng, Qing; Hassan, Muhammad; Wang, Xiaoyuan

    2014-05-01

    The nitrogen removal pathways and nitrogen-related functional genes in on-site three-stage aged refuse bioreactor (ARB) treating landfill leachate were investigated. It was found that on average 90.0% of CODCr, 97.6% of BOD5, 99.3% of NH4(+)-N, and 81.0% of TN were removed with initial CODCr, BOD5, NH4(+)-N, and TN concentrations ranging from 2323 to 2754, 277 to 362, 1237 to 1506, and 1251 to 1580 mg/L, respectively. Meanwhile, the functional genes amoA, nirS and anammox 16S rRNA gene were found to coexist in every bioreactor, and their relative proportions in each bioreactor were closely related to the pollutant removal performance of the corresponding bioreactor, which indicated the coexistence of multiple nitrogen removal pathways in the ARB. Detection of anammox expression proved the presence of the anammox nitrogen removal pathway during the process of recirculating mature leachate to the on-site ARB, which provides important information for nitrogen management in landfills.

  17. Critical management practices influencing on-site waste minimization in construction projects.

    Science.gov (United States)

    Ajayi, Saheed O; Oyedele, Lukumon O; Bilal, Muhammad; Akinade, Olugbenga O; Alaka, Hafiz A; Owolabi, Hakeem A

    2017-01-01

    As a result of increasing recognition of effective site management as the strategic approach for achieving the required performance in construction projects, this study seeks to identify the key site management practices that are requisite for construction waste minimization. A mixed methods approach, involving field study and survey research were used as means of data collection. After confirmation of construct validity and reliability of scale, data analysis was carried out through a combination of Kruskal-Wallis test, descriptive statistics and exploratory factor analysis. The study suggests that site management functions could significantly reduce waste generation through strict adherence to project drawings, and by ensuring fewer or no design changes during construction process. Provision of waste skips for specific materials and maximisation of on-site reuse of materials are also found to be among the key factors for engendering waste minimization. The result of factor analysis suggests four factors underlying on-site waste management practices with 96.093% of total variance. These measures include contractual provisions for waste minimization, waste segregation, maximisation of materials reuse and effective logistic management. Strategies through which each of the underlying measures could be achieved are further discussed in the paper. Findings of this study would assist construction site managers and other site operatives in reducing waste generated by construction activities.

  18. On-site Labour Productivity of New Zealand Construction Industry: Key Constraints and Improvement Measures

    Directory of Open Access Journals (Sweden)

    Serdar Durdyev

    2011-09-01

    Full Text Available Productivity is key to the survival and growth of any organisation, industry or nation. Some factors constrain the achievement of the set project objectives in the New Zealand building and construction industry and are responsible for the reported steady decline of productivity and performance. This study aims to identify the key constraints to on-site labour productivity and improvement measures. Using the descriptive survey method, views of some project managers, contractors and subcontractors in New Zealand were canvassed via pilot interviews and questionnaire surveys at the qualitative and quantity data gathering stages, respectively. Multi-attribute technique was used to analyse the quantitative data. Results showed that the key external constraints to on-site labour productivity comprise, in order of decreasing impact, statutory compliance, unforeseen events and wider external dynamics. The internal constraints, which contribute 67 percent of the onsite productivity issues, comprise reworks, level of skill and experience of the workforce, adequacy of method of construction, buildability issues, and inadequate supervision and coordination. . The factors underlying each broad category of external and internal constraints are reported. The relative levels of impact of the identified constraints are expected to guide the project team in addressing the constraints in a cost-effective manner.

  19. Analytical evaluation of four on-site oral fluid drug testing devices.

    Science.gov (United States)

    Vanstechelman, Sylvie; Isalberti, Cristina; Van der Linden, Trudy; Pil, Kristof; Legrand, Sara-Ann; Verstraete, Alain G

    2012-03-01

    The use of oral fluid (OF) as an alternative matrix for the detection of drugs of abuse has increased over the last decade, leading to the need for a rapid, simple, and reliable on-site OF testing device. Four on-site OF drug testing devices (Dräger DrugTest 5000, Cozart DDS, Mavand Rapid STAT, and Innovacon OrAlert) were evaluated on 408 volunteers at drug treatment centers. UPLC-MS-MS results were used as reference to determine sensitivity, specificity and accuracy for each device, applying Belgian legal confirmation cutoffs for benzoylecgonine, cocaine, and THC (10 ng/mL); morphine and 6-acetylmorphine (5 ng/mL); and amphetamine and 3,4-methylenedioxymethylamphetamine (25 ng/mL). Sensitivity for cocaine was 50%, 50%, 27%, and 11% for DrugTest, OrAlert, Rapid STAT, and DDS 806, respectively. For opiates, sensitivities were 84%, 73%, 77%, and 65%, respectively. For THC, the sensitivities were 81%, 23%, 43%, and 28%, respectively. For amphetamines, the sensitivities were 75%, 33%, 17%, and 67%, respectively. Specificity was >88% for opiates and THC, > 90% for amphetamines, and > 97% for cocaine. All tests showed good specificity. DrugTest had the highest sensitivity, although it was still low for some analytes.

  20. Reassessing Power

    Institute of Scientific and Technical Information of China (English)

    CHARLES; K.EBINGER; JOHN; P.BANKS

    2011-01-01

    Fukushima accident increases global concern over nuclear safety The accident at the Fukushima Daiichi Nuclear Power Plant in Japan has had an immediate impact on resurgent interest in nuclear power worldwide.Numerous governments have announced plans to re-examine nuclear energy policy and review the safety of their reactors and the adequacy of their regulatory frameworks.

  1. Power Drain

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Rising coal prices mean dwindling profits for China’s power plants. In some cases,they have forced plants to close their doors If electricity prices were not raised together with fuel prices, the country’spower plants could not survive. This isthe common voice of China’s power plants now.

  2. Power Source

    Science.gov (United States)

    Schooley, Michael L.

    2010-01-01

    Principals are powerful: They are the primary catalysts for creating a lasting foundation for learning, driving school and student performance, and shaping the long-term impact of school improvement efforts. Yet few principals would characterize themselves as powerful. Rather, they're self-effacing, adaptable, pragmatic, and quick to share credit…

  3. Diastatic power

    Science.gov (United States)

    diastatic power: Diastatic power, abbreviated DP, is the total activity of malt starch degrading enzymes that hydrolyze starch to fermentable sugars. The starch degrading enzymes contributing to this process are a-amylase, ß-amylase, limit dextrinase, and a-glucosidase. The driving force for DP a...

  4. Power system

    Science.gov (United States)

    Hickam, Christopher Dale

    2008-03-18

    A power system includes a prime mover, a transmission, and a fluid coupler having a selectively engageable lockup clutch. The fluid coupler may be drivingly connected between the prime mover and the transmission. Additionally, the power system may include a motor/generator drivingly connected to at least one of the prime mover and the transmission. The power-system may also include power-system controls configured to execute a control method. The control method may include selecting one of a plurality of modes of operation of the power system. Additionally, the control method may include controlling the operating state of the lockup clutch dependent upon the mode of operation selected. The control method may also include controlling the operating state of the motor/generator dependent upon the mode of operation selected.

  5. Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions.

    Science.gov (United States)

    Izumo, Takehiro; Matsumoto, Yuji; Sasada, Shinji; Chavez, Christine; Nakai, Toshiyuki; Tsuchida, Takaaki

    2017-03-01

    The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath. A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths. Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary.

  6. Evaluation of Gas-Cooled Pressurized Phosphoric Acid Fuel Cells for Electric Utility Power Generation

    Science.gov (United States)

    Faroque, M.

    1983-01-01

    Gas cooling is a more reliable, less expensive and a more simple alternative to conventional liquid cooling for heat removal from the phosphoric acid fuel cell (PAFC). The feasibility of gas-cooling was already demonstrated in atmospheric pressure stacks. Theoretical and experimental investigations of gas-cooling for pressurized PAFC are presented. Two approaches to gas cooling, Distributed Gas-Cooling (DIGAS) and Separated Gas-Cooling (SGC) were considered, and a theoretical comparison on the basis of cell performance indicated SGC to be superior to DIGAS. The feasibility of SGC was experimentally demonstrated by operating a 45-cell stack for 700 hours at pressure, and determining thermal response and the effect of other related parameters.

  7. Power Talk

    DEFF Research Database (Denmark)

    Liu, Hongpeng; Yang, Yongheng; Loh, Poh Chiang

    2016-01-01

    In this paper, a novel communication strategy called Power Talk is introduced to realize the power line communication among the Voltage Source Converters (VSC) of DC MicroGrids (MGs). Each VSC transmits information by changing the control parameters, and receives information by observing the local...... output power. By using common coding schemes, which transform the DC MGs in some familiar communication channels, some important communication challenges can be addressed, such as random load variations and VSCs switching, as it do not need a separate communication channel. For this purpose, two multiple...

  8. Temperature-dependent thermal conductivities of one-dimensional nonlinear Klein-Gordon lattices with a soft on-site potential.

    Science.gov (United States)

    Yang, Linlin; Li, Nianbei; Li, Baowen

    2014-12-01

    The temperature-dependent thermal conductivities of one-dimensional nonlinear Klein-Gordon lattices with soft on-site potential (soft-KG) are investigated systematically. Similarly to the previously studied hard-KG lattices, the existence of renormalized phonons is also confirmed in soft-KG lattices. In particular, the temperature dependence of the renormalized phonon frequency predicted by a classical field theory is verified by detailed numerical simulations. However, the thermal conductivities of soft-KG lattices exhibit the opposite trend in temperature dependence in comparison with those of hard-KG lattices. The interesting thing is that the temperature-dependent thermal conductivities of both soft- and hard-KG lattices can be interpreted in the same framework of effective phonon theory. According to the effective phonon theory, the exponents of the power-law dependence of the thermal conductivities as a function of temperature are only determined by the exponents of the soft or hard on-site potentials. These theoretical predictions are consistently verified very well by extensive numerical simulations.

  9. Temperature-dependent thermal conductivities of one-dimensional nonlinear Klein-Gordon lattices with a soft on-site potential

    Science.gov (United States)

    Yang, Linlin; Li, Nianbei; Li, Baowen

    2014-12-01

    The temperature-dependent thermal conductivities of one-dimensional nonlinear Klein-Gordon lattices with soft on-site potential (soft-KG) are investigated systematically. Similarly to the previously studied hard-KG lattices, the existence of renormalized phonons is also confirmed in soft-KG lattices. In particular, the temperature dependence of the renormalized phonon frequency predicted by a classical field theory is verified by detailed numerical simulations. However, the thermal conductivities of soft-KG lattices exhibit the opposite trend in temperature dependence in comparison with those of hard-KG lattices. The interesting thing is that the temperature-dependent thermal conductivities of both soft- and hard-KG lattices can be interpreted in the same framework of effective phonon theory. According to the effective phonon theory, the exponents of the power-law dependence of the thermal conductivities as a function of temperature are only determined by the exponents of the soft or hard on-site potentials. These theoretical predictions are consistently verified very well by extensive numerical simulations.

  10. A Review of On-Site Wastewater Treatment Systems in Western Australia from 1997 to 2011

    Directory of Open Access Journals (Sweden)

    Maria Gunady

    2015-01-01

    Full Text Available On-site wastewater treatment systems (OWTS are widely used in Western Australia (WA to treat and dispose of household wastewater in areas where centralized sewerage systems are unavailable. Septic tanks, aerobic treatment units (ATUs, and composting toilets with greywater systems are among the most well established and commonly used OWTS. However, there are concerns that some OWTS installed in WA are either performing below expected standards or failing. Poorly performing OWTS are often attributed to inadequate installation, inadequate maintenance, poor public awareness, insufficient local authority resources, ongoing wastewater management issues, or inadequate adoption of standards, procedures, and guidelines. This paper is to review the installations and failures of OWTS in WA. Recommendations to the Department of Health Western Australia (DOHWA and Local Government (LG in regard to management strategies and institutional arrangements of OWTS are also highlighted.

  11. A review of on-site wastewater treatment systems in Western Australia from 1997 to 2011.

    Science.gov (United States)

    Gunady, Maria; Shishkina, Natalia; Tan, Henry; Rodriguez, Clemencia

    2015-01-01

    On-site wastewater treatment systems (OWTS) are widely used in Western Australia (WA) to treat and dispose of household wastewater in areas where centralized sewerage systems are unavailable. Septic tanks, aerobic treatment units (ATUs), and composting toilets with greywater systems are among the most well established and commonly used OWTS. However, there are concerns that some OWTS installed in WA are either performing below expected standards or failing. Poorly performing OWTS are often attributed to inadequate installation, inadequate maintenance, poor public awareness, insufficient local authority resources, ongoing wastewater management issues, or inadequate adoption of standards, procedures, and guidelines. This paper is to review the installations and failures of OWTS in WA. Recommendations to the Department of Health Western Australia (DOHWA) and Local Government (LG) in regard to management strategies and institutional arrangements of OWTS are also highlighted.

  12. Corrosion rate of steel in concrete - Evaluation of confinement techniques for on-site corrosion rate

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica; Elsener, Bernhard

    2009-01-01

    Earlier on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when different commercially available instruments are used. The different confinement techniques, rather than the different electrochemical techniques used in the instruments, are considered...... to be the main reason for the discrepancies. This paper presents a method for the quantitative assessment of confinement techniques based on monitoring the operation of the corrosion rate instrument and the current distribution between the electrode assembly on the concrete surface and a segmented reinforcement...... bar embedded in the concrete. The applicability of the method was demonstrated on two commercially available corrosion rate instruments based on different confinement techniques. The method provided an explanation of the differences in performance of the two instruments. Correlated measurements...

  13. Case reports of on-site investigations of auger-related farm injuries.

    Science.gov (United States)

    Ingram, M W; Crowe, T G; Wassermann, J; Hagel, L M; Dosman, J A

    2003-05-01

    Previous reports have indicated that injuries involving augers (screw conveyors) are a serious problem in agriculture, but to date on-site engineering inspections linking injuries to mechanical and procedural aspects have not been available. This article details four events involving injuries as the result of being entangled in auger flighting. In each report, the circumstances surrounding the injury event are outlined, and the machinery involved is evaluated in terms of its compliance with current safety standards. In three of the four instances, the machinery did not conform to current guarding standards or to safety sign standards. In these three cases, injuries were preventable with improved guarding according to ASAE Standards. In the other case, the machine complied with ASAE Standards, but the injury could have been prevented with improved guarding of the auger flighting.

  14. Rapid Analytical Methods for On-Site Triage for Traumatic Brain Injury

    Science.gov (United States)

    North, Stella H.; Shriver-Lake, Lisa C.; Taitt, Chris R.; Ligler, Frances S.

    2012-07-01

    Traumatic brain injury (TBI) results from an event that causes rapid acceleration and deceleration of the brain or penetration of the skull with an object. Responses to stimuli and questions, loss of consciousness, and altered behavior are symptoms currently used to justify brain imaging for diagnosis and therapeutic guidance. Tests based on such symptoms are susceptible to false-positive and false-negative results due to stress, fatigue, and medications. Biochemical markers of neuronal damage and the physiological response to that damage are being identified. Biosensors capable of rapid measurement of such markers in the circulation offer a solution for on-site triage, as long as three criteria are met: (a) Recognition reagents can be identified that are sufficiently sensitive and specific, (b) the biosensor can provide quantitative assessment of multiple markers rapidly and simultaneously, and (c) both the sensor and reagents are designed for use outside the laboratory.

  15. Recycling of treated domestic effluent from an on-site wastewater treatment system for hydroponics.

    Science.gov (United States)

    Oyama, N; Nair, J; Ho, G E

    2005-01-01

    An alternative method to conserve water and produce crops in arid regions is through hydroponics. Application of treated wastewater for hydroponics will help in stripping off nutrients from wastewater, maximising reuse through reduced evaporation losses, increasing control on quality of water and reducing risk of pathogen contamination. This study focuses on the efficiency of treated wastewater from an on-site aerobic wastewater treatment unit. The experiment aimed to investigate 1) nutrient reduction 2) microbial reduction and 3) growth rate of plants fed on wastewater compared to a commercial hydroponics medium. The study revealed that the chemical and microbial quality of wastewater after hydroponics was safe and satisfactory for irrigation and plant growth rate in wastewater hydroponics was similar to those grown in a commercial medium.

  16. Modelling of moving bed biofilm membrane reactors (MBBMR) for on-site greywater treatment.

    Science.gov (United States)

    Jabornig, Simon; Rauch, Wolfgang

    2015-01-01

    The study evaluates with a mechanistic model the pilot plant results of a combined moving bed biofilm process and membrane filtration (MBBMR) treating single household greywater. It mainly includes the simulation of reactor hydraulics, degradation of pollutants, development of biomass and settlement of sludge. Iterative calibration was made with steady-state results of a 10-month pilot test. The model shows good predictions of readily biodegradable chemical oxygen demand and ammonium removal, as well as biomass concentration on carriers and in suspension. Also, a sensitivity analysis was made which calculates the relative significance factor of each model coefficient and by this provides comparability with other studies. Simulation data and actually measured parameters show that the suggested process was rather independent of ambient temperatures and short-term load fluctuations. Obtained datasets and model structure could be of use for future designers, as well as sellers and users of this process for on-site greywater reclamation.

  17. On-site field test on groundwater re-flooding (2)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-02-01

    A mini-dome (an underground structure to be closed; ground level: - 50 m to - 82.5 m) situated on a diluvium along the Sagami River, Kanagawa prefecture, Japan, was used to perform an on-site field tests on groundwater re-flooding for 11 months after the mini-dome was filled up with sand, mortar, and fluidized soil consisting of cement and mudwater. The present report includes monitoring data of the environmental groundwater at the surrounding bed rocks and of the groundwater in the deep mudstone beneath the site. Change with time at various test points in water pressure, water temperature, pH, electric conductivity, and the temperature of the wall of the structure making the mini-dome is reported. Furthermore, some isotopic abundance and the monitoring results on chemical analysis were also included. (S. Ohno)

  18. On-site and laboratory evaluations of soundscape quality in recreational urban spaces

    DEFF Research Database (Denmark)

    Bjerre, Lærke Cecilie; Larsen, Thea Mathilde; Sørensen, Anna Josefine

    2017-01-01

    assessment in the presence of the full on-site context, the visual context only, and without context. Materials and Methods: Soundscape quality was evaluated for three recreational urban spaces by using four subjective attributes: loudness, acceptance, stressfulness, and comfort. The sound level was measured......Context: Regulations for quiet urban areas are typically based on sound level limits alone. However, the nonacoustic context may be crucial for subjective soundscape quality. Aims: This study aimed at comparing the role of sound level and nonacoustic context for subjective urban soundscape...... evaluating overall soundscape quality in urban recreational areas. Laboratory evaluations may not fully reflect how subjective loudness, acceptance, stressfulness, and comfort are affected by sound level....

  19. On-site and laboratory evaluations of soundscape quality in recreational urban spaces

    DEFF Research Database (Denmark)

    Bjerre, Lærke Cecilie; Larsen, Thea Mathilde; Sørensen, Anna Josefine

    2017-01-01

    in the presence of the full on-site context, the visual context only, and without context. Materials and Methods: Soundscape quality was evaluated for three recreational urban spaces by using four subjective attributes: loudness, acceptance, stressfulness, and comfort. The sound level was measured at each site......Regulations for quiet urban areas are typically based on sound level limits alone. However, the nonacoustic context may be crucial for subjective soundscape quality. Aims: This study aimed at comparing the role of sound level and nonacoustic context for subjective urban soundscape assessment...... quality in urban recreational areas. Laboratory evaluations may not fully reflect how subjective loudness, acceptance, stressfulness, and comfort are affected by sound level....

  20. Methods and apparatus for the on-site production of hydrogen peroxide

    Science.gov (United States)

    Buschmann, Wayne E. (Inventor); James, Patrick I. (Inventor)

    2010-01-01

    Methods, apparatus, and applications for the on-site production of hydrogen peroxide are described. An embodiment of the apparatus comprises at least one anolyte chamber coupled to at least one anode, at least one catholyte chamber, wherein the at least one catholyte chamber is coupled to at least one cathode, at least one anode membrane and at least one cathode membrane, wherein the anode membrane is adjacent to the at least one anode, wherein the cathode membrane is adjacent to the at least one cathode, at least one central chamber disposed between the at least one anolyte chamber and the at least one catholyte chamber. Hydrogen peroxide is produced by reduction of an oxygen-containing gas at the cathode.

  1. Modeling injury rates as a function of industrialized versus on-site construction techniques.

    Science.gov (United States)

    Rubio-Romero, J C; Suárez-Cebador, M; Abad, Jesús

    2014-05-01

    It is often predicted that the industrialization of building activities will lead to a reduction of accident rates in the construction sector, particularly as a result of switching activities from building sites to factories. However, to date no scientific research has provided objective quantitative results to back up this claim. The aim of this paper is to evaluate how industrialization affects the accident rate in different industrialized building systems in Spain. Our results revealed that the industrialized steel modular system presents the lowest accident rate, while the highest accident rate was recorded in the construction method with cast-in-place concrete. The lightweight construction system also presents a high accident rate. Accordingly, industrialized building systems cannot claim to be safer than traditional ones. The different types of "on-site work" seem to be the main variable which would explain the accident rates recorded in industrialized construction systems.

  2. Assessing occupational mercury exposures during the on-site processing of spent fluorescent lamps.

    Science.gov (United States)

    Lucas, Alan; Emery, Robert

    2006-03-01

    On-site processing of spent fluorescent lamps reduces storage space requirements and prevents mercury-containing lamp contents from entering the municipal waste stream, but such processing activities are typically not carried out in facilities specifically designed for the operation. This circumstance is of particular concern because lamp-handling and -crushing operations can release mercury vapors and aerosols that constitute an occupational exposure risk. In the study reported here, sampling for airborne mercury was performed during the processing of fluorescent lamps in an enclosed work area and in an open, outdoor work environment. In both enclosed and open work environments, exposures in excess of the established mercury exposure limit were detected. Simple interventions to prevent this possible unanticipated source of mercury exposure are described.

  3. Validation of on-site job-built guardrails with shoring jack as supports

    Directory of Open Access Journals (Sweden)

    Lan, A.

    2014-06-01

    Full Text Available To protect themselves against fall hazards in a slab-column frame, workers use the row of shoring jacks installed at 1 m from the edge as supports for on-site built guardrails. Inspectors of the Quebec Workers Compensation Board (Commission de la santé et de la sécurité du travail (CSST have expressed concern about the safety and compliance of these on-site built guardrails with the Quebec Safety Code for the Construction Industry (S-2.1, r.4. Some workers have also inquired if the shoring jack can be used as an anchor for a travel restraint system. The present study describes how an evaluation method and a test protocol have been used to verify if guardrails built on-site, with shoring jacks as supports, are safe and comply with the requirements of S-2.1, r.4 and if the shoring jack can be used as an anchor point for a travel restraint system. The results of the study show 1 guardrails built on site with shoring jacks as supports, are safe and comply with S-2.1, r.4 and 2 shoring jacks used as supports for guardrails must not be used as an anchor for a travel restraint system.Para la protección contra el peligro de caída en altura durante la ejecución de la estructura de un edificio, los trabajadores utilizan puntales acodalados a dos forjados y situados a 1 metro del borde de forjado como apoyo de las barandillas de seguridad. Inspectores de la Quebec Workers Compensation Board (Commision de la santé et de la sécurité du travail (CSST han expresado su preocupación por la seguridad y el cumplimiento de estos sistemas de protección en la construcción conforme al Código de Seguridad de Quebec para la industria de la construcción (S-2.1, R.6. Así mismo algunos trabajadores han mostrado su inquietud sobre la utilización de los puntales como sistemas para limitar el desplazamiento. El presente estudio describe un método de evaluación y un procedimiento de ensayo que se han utilizado para verificar si las barandillas de seguridad

  4. Corrosion rate of steel in concrete - Evaluation of confinement techniques for on-site corrosion rate

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica; Elsener, Bernhard

    2009-01-01

    Earlier on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when different commercially available instruments are used. The different confinement techniques, rather than the different electrochemical techniques used in the instruments, are considered...... to be the main reason for the discrepancies. This paper presents a method for the quantitative assessment of confinement techniques based on monitoring the operation of the corrosion rate instrument and the current distribution between the electrode assembly on the concrete surface and a segmented reinforcement...... bar embedded in the concrete. The applicability of the method was demonstrated on two commercially available corrosion rate instruments based on different confinement techniques. The method provided an explanation of the differences in performance of the two instruments. Correlated measurements...

  5. Power Preservation

    DEFF Research Database (Denmark)

    Galster, Kjeld

    Power Preservation (Abstract) In the 17th century, just as today, coalitions needed ‘lead nations’. This was assumed to be a power with great military and economic potentials, and Denmark endeavoured to act as such a leader in the Thirty Years War from 1626 to 28. The results were not encouraging...... in the military field and they were disastrous as far as fiscal matters were concerned. Sweden took over the leadership of the protestant side and she took over Denmark’s place amongst the great powers of the Baltic Region. From that time onwards, Danish influence and options on the international stage gradually...... declined. Thus, Denmark of the 17th century is not to be counted amongst the great powers, but since Christian V’s accession to the throne in 1670 Denmark-Norway has developed into one of Europe’s most highly militarised states. Apart from a permanently combat ready navy, the country maintains a standing...

  6. Evaluating indigenous grass species as on-site sediment trapping measures, northwest Ethiopian highlands

    Science.gov (United States)

    Mekonnen, Mulatie; Keesstra, Saskia; Ritsema, Coen; Stroosnijder, Leo; Baartman, Jantiene

    2016-04-01

    Although many studies have been conducted to evaluate the sediment trapping efficacy (STE) of grass species as an on-site sediment trapping measure, still a lot of grass species are availab1e of which their STE is unknown. Lack of information on the STE of such grass species has a negative influence on their acceptance and practical application by the users. Therefore, this study was conducted at Debre Mewi watershed, northwestern Ethiopian highlands, to evaluate the STE of four locally dominant indigenous grass species (Desho, Senbelet, Akirma and Sebez) and one exotic species (Vetiver) using plot experiments. On average, the annual runoff produced was found to be 79; 64; 69; 71; 74; 75 l m-2, which resulted in 7; 1.7; 2.9; 3.6; 4.5 and 5.6 kg m-2 yr-1 of sediment yield on the Control, Desho, Vetiver, Senbelet, Akirma and Sebez plots, respectively. Desho had a trapping efficacy of 76 % because of its fast growth and lateral spreading nature. Vetiver and Senbelet reduced the transported sediment with 59 % and 49 % STE, respectively. Because of their slow growth nature, Akirma and Sebez showed low STEs, 36 % and 20 %, respectively. The grass species were found to be important sources of livestock feed in addition to trapping sediment and reducing soil loss. Desho, Senbelet, Akirma, Vetiver and Sebez provided 132, 106, 76, 69 and 51 t ha-1 yr-1 fresh biomass, respectively. The indigenous grass species provided a practical means to reduce sediment yield, therefore, it can be concluded that such indigenous grass species can be used as an on-site sediment trapping measure in the northwestern highlands of Ethiopia.

  7. Revaluation of breast cytology with pathologist on-site of lesions with suspicious sonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Capalbo, Emanuela, E-mail: emanuelacapalbo@tiscalinet.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Sajadidehkordi, Farideh, E-mail: faridehit@yahoo.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Colombi, Claudio; Ticha, Vladimira; Moretti, Angela, E-mail: info.radiologia@sancarlo.mi.it [Dipartimento di Scienze Diagnostiche, UOC di Radiologia Diagnostica ed Interventistica, A.O San Carlo Borromeo. Via Pio II, 3, 20153 Milano (Italy); Peli, Michela, E-mail: peli.michela@gmail.com [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Cosentino, Maria, E-mail: maria-cosentino@tiscali.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Lovisatti, Maria, E-mail: marialovisatti@hotmail.com [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Berti, Elisabetta, E-mail: eliberti@hotmail.it [Dipartimento di Scienze Diagnostiche, UOC di Anatomia Patologica, A.O San Carlo Borromeo. Via Pio II, 3, Milano 20153 (Italy); Cariati, Maurizio, E-mail: info.radiologia@sancarlo.mi.it [Dipartimento di Scienze Diagnostiche, UOC di Radiologia Diagnostica ed Interventistica, A.O San Carlo Borromeo. Via Pio II, 3, 20153 Milano (Italy)

    2013-09-15

    Objective: Evaluating correlation estimation between diagnostic ultrasound (U.S.) of breast lesions and fine needle aspiration cytology (FNAC), and the correlation between cytology and histology (I) of these lesions undergo surgery. Materials and methods: In 2010 we performed 1589 ultrasound breast. We identified 210 suspicious lesions to be subjected to FNAC, which was performed with pathologist on site, and extemporaneous analysis of the sample to assess their appropriateness. We classified the lesions in 5 ultrasound (U) classes according to the criteria defined by Echographic BIRADS Lexicon. The results of cytology were classified in 5 classes (C) according to the guidelines of F.O.N.Ca.M. Then we evaluated the diagnostic correlation between U.S. and FNAC, and between FNAC and Histology. Results: The distribution of lesions in U classes was: 57U2, 55U3, 36U4 and 62U5. The diagnostic concordance between U and FNAC was 96.7%, with a sensitivity of 98%, specificity 93%, negative and positive predictive value respectively of 94.9% and 97.3%, and diagnostic accuracy of 96.6%. The 98 patients with C4-C5 lesions were subjected to surgery and the histology confirmed high-grade malignancy of lesions with a concordance of 99.7%. Conclusions: Having achieved high diagnostic concordance between U and FNAC, and then between FNAC and histology, we may say that the FNAC, less invasive and traumatic for the patient than needle biopsy (CB), may be still a valid method when performed with pathologist on-site to assess the adequacy of the sample taken.

  8. An on-site alert level early warning system for Italy

    Science.gov (United States)

    Caruso, Alessandro; Colombelli, Simona; Elia, Luca; Zollo, Aldo

    2017-04-01

    An Earthquake Early Warning (EEW) system is a real-time seismic monitoring infrastructure that has the capability to provide warnings to target cities before the arrival of the strongest shaking waves. In order to provide a rapid alert when targets are very close to the epicenter of the events, we developed an on-site EEW approach and evaluated its performance at the nation-wide scale of Italy. We use a single-station, P-wave based method that measures in real-time two ground motion quantities along the early P-wave signal: the initial Peak Displacement (Pd) and the average period parameter (τc). In output, the system provides the predicted ground shaking intensity at the monitored site, the alert level (as defined by Zollo et al., 2010) and a qualitative classification of both earthquake magnitude and source-to-receiver distance. We applied the on-site EEW methodology to a dataset of Italian earthquakes, recorded by the Italian accelerometric network, with magnitude ranging from 3.8 to 6, and evaluated the performance of the system in terms of correct warning and lead-times (i.e., time available for security actions at the target). The results of this retrospective analysis show that, for the large majority of the analyzed cases, the method is able to deliver a correct warning shortly after the P-wave detection, with more than 80% of successful intensity predictions at the target site. The lead-times increase with distance, with a value of 2-6 seconds at 30 km, 8-10 seconds at 50 km and 15-18 seconds at 100 km.

  9. Introduction to electrical power and power electronics

    CERN Document Server

    Patel, Mukund R

    2012-01-01

    Power Generation, Distribution, and Utilization AC Power Fundamentals Common Aspects of Power Equipments AC Generator AC and DC Motors Transformer Power Cable Power Distribution Fault Current Analysis System ProtectionEconomic Use of PowerElectrochemical BatteryPower Electronics and Motor Drives Power Electronics Devices DC-DC Converters AC-DC-AC Converters Variable-Frequency Drives Quality of Power Power Converter CoolingAppendixIndex

  10. 76 FR 32227 - DST Systems, Inc., Including On-Site Leased Workers From Comsys Information Technology Services...

    Science.gov (United States)

    2011-06-03

    ... information processing, computer software services, and business solutions, to the financial services... Employment and Training Administration DST Systems, Inc., Including On-Site Leased Workers From Comsys Information Technology Services, Megaforce, and Kelly Services Kansas City, MO; DST Technologies, a...

  11. 77 FR 40638 - Alternative Staffing, Formerly Known as First Choice Staffing, Working On-Site at Ametek...

    Science.gov (United States)

    2012-07-10

    ... On-Site at Ametek Nationals Controls Corporation, Instrumentation and Speciality Controls Division..., Instrumentation and Specialty Control Division, West Chicago, Illinois. The Department's notice of determination...) controls and stand-alone timers, industrial process controls, controls for industrial air filters,...

  12. 77 FR 14832 - Plumchoice, Inc., Including On-Site Leased Workers From Balance Staffing, Insight Global Staffing...

    Science.gov (United States)

    2012-03-13

    ... Staffing, Insight Global Staffing, and Technisource, Scarborough, ME; Amended Certification Regarding..., Inc., including on-site leased workers from Balance Staffing, Insight Global Staffing, and... from Balance Staffing, Insight Global Staffing, and Technisource, Scarborough, Maine, who...

  13. 77 FR 31643 - Siltronic Corporation FAB1 Plant Including On-Site Leased Workers From Express Temporaries...

    Science.gov (United States)

    2012-05-29

    ... on April 27, 2012 (77 FR 25201). The workers were engaged in the production of silicon wafers. At the... workers leased from the afore-mentioned agencies who work(ed) on-site at subject firm. The amended...

  14. 75 FR 67770 - Sara Lee Corporation Including On-Site Leased Workers From EDS, Hewitt Packard, Sapphire...

    Science.gov (United States)

    2010-11-03

    ..., Cash Applications, Deductions, Collections, Call Center, Information Technology, Accounts Payable, General Accounts, Financial Accounts, Payroll, and Employee Master Data Departments Including On-Site... Payable, General Accounts, Financial Accounts, Payroll, and Employee Master Data Departments, including...

  15. 75 FR 22627 - Chrysler LLC, St. Louis North Assembly Plant Including On-Site Leased Workers From HAAS TCM, Inc...

    Science.gov (United States)

    2010-04-29

    ... Workers From HAAS TCM, Inc., Logistics Services, Inc., Robinson Solutions, Logistics Management Services..., including on-site leased workers from HAAS TCM, Inc., Logistics Services, Inc., Robinson Solutions, Logistics Management Services, Inc., Corrigan Company and Murphy Company, Fenton, Missouri, who...

  16. 78 FR 48467 - Delphi Automotive Systems, LLC, Products and Service Solutions Division, Including On-Site Leased...

    Science.gov (United States)

    2013-08-08

    ... Employment and Training Administration Delphi Automotive Systems, LLC, Products and Service Solutions... workers of Delphi Automotive Systems, LLC, Product and Service Solutions Division, Original Equipment... of ] Delphi Automotive Systems, LLC, Product and Service Solutions Division, including on-site...

  17. Use of On-Site GC/MS Analysis to Distinguish between Vapor Intrusion and Indoor Sources of VOC

    Science.gov (United States)

    2013-12-01

    ER-201119) Use of On-Site GC/MS Analysis to Distinguish between Vapor Intrusion and Indoor Sources of VOC December 2013 This document...SUBTITLE Use of On-Site GC/MS Analysis to Distinguish between Vapor Intrusion and Indoor Sources of VOC 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...ANALYSIS TO EVALUATE VAPOR INTRUSION ........................ 21 6.3.1 Site-by-Site Analysis of Results: Building VI Classifications ................. 21

  18. High Power Factor Power Design

    Directory of Open Access Journals (Sweden)

    Zhang Jing-yi

    2013-07-01

    Full Text Available The PFC circuit takes UCC28019 made by TI Company as the core of system control, realize the power factor correction circuit functions, and the circuit power factor can be measured. Through a variety of detection circuit, with the support SCM control. And 30V~36V output voltage regulator can be set; with over-current protection circuits function, and be able to automatically back. Output current, voltage, and little significant value are displayed by display modules.

  19. Cocaine and benzoylecgonine oral fluid on-site screening and confirmation.

    Science.gov (United States)

    Ellefsen, Kayla N; Concheiro, Marta; Pirard, Sandrine; Gorelick, David A; Huestis, Marilyn A

    2016-01-01

    Accurate on-site devices to screen for drug intake are critical for establishing whether an individual is driving under the influence of drugs (DUID); however, on-site oral fluid (OF) cocaine device performance is variable. We evaluated the performance of a newly developed benzoylecgonine (BE) test-strip for the Draeger® DrugTest 5000 device (20 µg/L cut-off) with equivalent cross reactivity for cocaine and BE. Ten cocaine users provided OF, collected with the Draeger cassette and Oral-Eze® and StatSure Saliva Sampler(TM) devices, up to 69 h following 25 mg intravenous cocaine administration. All screening results were confirmed by a validated two-dimensional-gas chromatography-mass spectrometry (2D-GC-MS) method for cocaine and/or BE. Cocaine test-strip median Tlast for screening only results was 6.5 h, and 6.5 h with Oral-Eze® and 4 h for StatSure OF confirmation for cocaine and/or BE at 1, 8, and 10 µg/L; sensitivity, specificity, and efficiency ranged from 85.5 to 100% and 83.3 to 100% for cocaine only confirmation at 8 and 10 µg/L. For the BE test-strip, median Tlast was 12.5 h for screening only and confirmation for cocaine and/or BE at all three cut-offs; sensitivity, specificity, and efficiency ranged from 85.5 to 97.5% and 78.4 to 97.4% with cocaine and/or BE confirmation at 8 and 10 µg/L cut-offs, respectively. The Draeger cocaine test-strip with cocaine only confirmation offers a useful option for monitoring the acute intoxication phase of DUID; additionally the BE test-strip with cocaine and/or BE confirmation increases the length of detection of cocaine intake for workplace drug testing, drug court, parole, pain management, drug treatment programs and both the acute cocaine intoxication and cocaine crash/fatigue phase of DUID. Copyright © 2016 John Wiley & Sons, Ltd.

  20. A P-wave based, on-site method for Earthquake Early Warning

    Science.gov (United States)

    Zollo, Aldo

    2016-04-01

    Can we rapidly predict the potential damage of earthquakes by-passing the estimation of its location and magnitude? One possible approach is to predict the expected peak ground shaking at the site and the earthquake magnitude from the initial P-peak amplitude and characteristic period, respectively. The idea, first developed by Wu and Kanamori (2005), is to combine the two parameters for declaring the alert once the real-time measured quantities have passed pre-defined thresholds. Our proposed on-site early warning method generalized this approach, based on the analysis of strong motion data from modern accelerograph networks in Japan, Taiwan and Italy (Zollo et al., 2010). It is based on the real-time measurement of the period (τc) and peak displacement (Pd) parameters at one or more co-located stations at a given target site to be protected against the earthquake effects. By converting these real-time proxies in predicted values of Peak Ground Velocity (PGV) or instrumental intensity (IMM) and magnitude, an alert level is issued at the recording site based on a decisional table with four entries defined upon threshold values of the parameters Pd and Tc. The latter ones are set according to the error bounds estimated on the derived prediction equations. A near-source network of stations running the onsite method can provide the event location and transmit the information about the alert levels recorded at near-source stations to more distant sites, before the arrival of the most destructive phase. The network-based approach allows for the rapid and robust estimation of the Potential Damage Zone (PDZ), that is the area where most of earthquake damage is expected (Colombelli et al., 2012). A new strategy for a P-wave based, on-site earthquake early warning system has been developed and tested on Japanese strong motion data and under testing on Italian data. The key elements are the real-time, continuous measurement of three peak amplitude parameters and their

  1. Power Down

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ Cai Wending and his colleague Xie Changsheng have been living out of a suitcase for the past two months.The pair,managers at a coal-fired power plant in Hunan Province,have been staying in a modest three-star hotel in Jincheng,a small city in Shanxi Province.They are not the only long-term residents of the hotel.Numerous power plant officials have been drawn to Jincheng from across China,all for the same purpose-to buy coal.

  2. Application of On-Site Wastewater Treatment in Ireland and Perspectives on Its Sustainability

    Directory of Open Access Journals (Sweden)

    Donata Dubber

    2014-03-01

    Full Text Available The wastewater of one third of Ireland’s population is treated on-site using domestic treatment systems (DWWTSs that usually consist of a septic tank and soil attenuation system. Within the past four years, the legislative framework for these systems has undergone a major change with a registration and inspection regime being introduced to identify legacy sites that will require remediation work, particularly in areas of the country underlain by subsoils of very low permeability. Against this background this study aims to assess the overall sustainability of existing DWWTSs as well as alternative treatment and disposal options. The results show that main CO2eq emissions are from the methane production in septic tanks. The reduced methane production in mechanically aerated secondary treatment systems was found to counterbalance the related emissions due to the additional energy requirements. In contrast, septic tank systems have the lowest construction and operational costs representing the most economically sustainable solution. Pressurised disposal systems are slightly more expensive but have the potential to reduce environmental impact on surface water and reduce greenhouse gas emissions. Clustered decentralised treatment solutions could be environmentally and economically sustainable but ownership, management and related financial and legal issues will need to be addressed and developed.

  3. Rapid one-step assays for on-site monitoring of mouse and rat urinary allergens.

    Science.gov (United States)

    Koets, Marjo; Renström, Anne; Zahradnik, Eva; Bogdanovic, Jelena; Wouters, Inge M; van Amerongen, Aart

    2011-12-01

    Allergy to rodent proteins is common among laboratory animal workers. Sensitive methods to measure exposure to these allergens have been developed. These assays are, however, expensive, time-consuming, and require a laboratory facility and methodological expertise. A simple method to screen for allergen spread, or to test whether hygiene standards are maintained, would be useful. Lateral flow immunoassays (LFIAs) are especially suited for field settings; the tests are simple and results are visible within minutes. LFIAs were developed for detection of the rodent urinary allergens Mus m 1 and Rat n 1. Pilot studies were performed in animal facilities in three countries using both extracts from airborne dust samples and samples collected by wiping surfaces. For comparison and determination of sensitivity, the concentrations of rodent urinary allergens in the samples were also measured using enzyme immunoassays (EIAs). The LFIAs for rat and mouse urinary allergens had a detection limit of 31 pg allergen per mL in a buffer system with purified allergen standards. Results of environmental dust extracts tested in LFIAs correlated well with levels obtained using EIAs. Spread of rodent allergens, or non-adherence to hygiene around laboratory animal facilities, may aggravate rodent allergy. Using a simple, sensitive one-step assay, allergens can be detected to prevent allergen exposure. The results reveal that the rapid assays are suited for on-site demonstration of exposure to rodent allergens, and thus, useful in occupational hygiene practice.

  4. Estimated costs of implementation of membrane processes for on-site greywater recycling.

    Science.gov (United States)

    Humeau, P; Hourlier, F; Bulteau, G; Massé, A; Jaouen, P; Gérente, C; Faur, C; Le Cloirec, P

    2011-01-01

    Greywater reuse inside buildings is a possible way to preserve water resources and face up to water scarcity. This study is focused on a technical-economic analysis of greywater treatment by a direct nanofiltration (NF) process or by a submerged membrane bioreactor (SMBR) for on-site recycling. The aim of this paper is to analyse the cost of recycled water for two different configurations (50 and 500 inhabitants) in order to demonstrate the relevance of the implementation of membrane processes for greywater recycling, depending on the production capacity of the equipment and the price of drinking water. The first step was to define a method to access the description of the cost of producing recycled water. The direct costs were defined as a sum of fixed costs due to equipment, maintenance and depreciation, and variable costs generated by chemical products and electricity consumptions. They were estimated from an experimental approach and from data found in literature, enabling operating conditions for greywater recycling to be determined. The cost of treated water by a SMBR unit with a processing capacity of 500 persons is close to 4.40 euros m(-3), while the cost is 4.81 euros m(-3) with a NF process running in the same conditions. These costs are similar to the price of drinking water in some European countries.

  5. Au dotted magnetic network nanostructure and its application for on-site monitoring femtomolar level pesticide.

    Science.gov (United States)

    Yang, Tianxi; Guo, Xiaoyu; Wang, Hui; Fu, Shuyue; Yu, Jie; Wen, Ying; Yang, Haifeng

    2014-04-09

    A novel magnetically responsive and surface-enhanced Raman spectroscopy (SERS) active nanocomposite is designed and prepared by direct grafting of Au nanoparticles onto the surface of magnetic network nanostructure (MNN) with the help of a nontoxic and environmentally friendly reagent of inositol hexakisphosphate shortly named as IP6. The presence of IP6 as a stabilizer and a bridging agent could weave Fe3O4 nanoparticles (NPs) into magnetic network nanostructure, which is easily dotted with Au nanoparticles (Au NPs). It has been shown firstly that the huge Raman enhancement of Au-MNN is reached by an external magnetic collection. Au-MNN presenting the large surface and high detection sensitivity enables it to exhibit multifunctional applications involving sufficient adsorption of dissolved chemical species for enrichment, separation, as well as a Raman amplifier for the analysis of trace pesticide residues at femtomolar level by a portable Raman spectrometer. Therefore, such multifunctional nanocomposites can be developed as a smart and promising nanosystem that integrates SERS approach with an easy assay for concentration by an external magnet for the effective on-site assessments of agricultural and environmental safety.

  6. The Cherenkov Telescope Array On-Site integral sensitivity: observing the Crab

    CERN Document Server

    Fioretti, Valentina; Schussler, Fabian

    2016-01-01

    The Cherenkov Telescope Array (CTA) is the future large observatory in the very high energy (VHE) domain. Operating from 20 GeV to 300 TeV, it will be composed of tens of Imaging Air Cherenkov Telescopes (IACTs) displaced in a large area of a few square kilometers in both the southern and northern hemispheres. The CTA/DATA On-Site Analysis (OSA) is the system devoted to the development of dedicated pipelines and algorithms to be used at the CTA site for the reconstruction, data quality monitoring, science monitoring and realtime science alerting during observations. The OSA integral sensitivity is computed here for the most studied source at Gamma-rays, the Crab Nebula, for a set of exposures ranging from 1000 seconds to 50 hours, using the full CTA Southern array. The reason for the Crab Nebula selection as the first example of OSA integral sensitivity is twofold: (i) this source is characterized by a broad spectrum covering the entire CTA energy range; (ii) it represents, at the time of writing, the standar...

  7. On-site variety discrimination of tomato plant using visible-near infrared reflectance spectroscopy

    Institute of Scientific and Technical Information of China (English)

    Hui-rong XU; Peng YU; Xia-ping FU; Yi-bin YING

    2009-01-01

    The use of visible-near infrared (NIR) spectroscopy was explored as a tool to discriminate two new tomato plant varieties in China (Zheza205 and Zheza207).In this study,82 top-canopy leaves of Zheza205 and 86 top-canopy leaves of Zheza207 were measured in visible-NIR reflectance mode.Discriminant models were developed using principal component analysis (PCA),discriminant analysis (DA),and discriminant partial least squares (DPLS) regression methods.After outliers detection,the samples were randomly split into two sets,one used as a calibration set (n=82) and the remaining samples as a validation set (n=82).When predicting the variety of the samples in validation set,the classification correctness of the DPLS model after optimizing spectral pretreatment was up to 93%.The DPLS model with raw spectra after multiplicative scatter correction and Savitzky-Golay filter smoothing pretreatments had the best satisfactory calibration and prediction abilities (correlation coefficient of calibration (Rc)=0.920,root mean square errors of calibration=0.196,and root mean square errors of prediction=0.216).The results show that visible-NIR spectroscopy might be a suitable alternative tool to discriminate tomato plant varieties on-site.

  8. Bioremediation techniques-classification based on site of application: principles, advantages, limitations and prospects.

    Science.gov (United States)

    Azubuike, Christopher Chibueze; Chikere, Chioma Blaise; Okpokwasili, Gideon Chijioke

    2016-11-01

    Environmental pollution has been on the rise in the past few decades owing to increased human activities on energy reservoirs, unsafe agricultural practices and rapid industrialization. Amongst the pollutants that are of environmental and public health concerns due to their toxicities are: heavy metals, nuclear wastes, pesticides, green house gases, and hydrocarbons. Remediation of polluted sites using microbial process (bioremediation) has proven effective and reliable due to its eco-friendly features. Bioremediation can either be carried out ex situ or in situ, depending on several factors, which include but not limited to cost, site characteristics, type and concentration of pollutants. Generally, ex situ techniques apparently are more expensive compared to in situ techniques as a result of additional cost attributable to excavation. However, cost of on-site installation of equipment, and inability to effectively visualize and control the subsurface of polluted sites are of major concerns when carrying out in situ bioremediation. Therefore, choosing appropriate bioremediation technique, which will effectively reduce pollutant concentrations to an innocuous state, is crucial for a successful bioremediation project. Furthermore, the two major approaches to enhance bioremediation are biostimulation and bioaugmentation provided that environmental factors, which determine the success of bioremediation, are maintained at optimal range. This review provides more insight into the two major bioremediation techniques, their principles, advantages, limitations and prospects.

  9. On-site monitoring of fish spoilage using vanadium pentoxide xerogel modified interdigitated gold electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Helali, S.; Abdelghani, A. [Unite de Recherche de Physique des Semiconducteurs et Capteurs, IPEST (Tunisia); Jaffrezic-Renault, N. [Laboratoire de Sciences Analytiques, Universite de Claude Bernard, Lyon (France); Trikalitis, P.N. [Department of Chemistry, University of Crete, 71 003, Heraklion Crete (Greece); Efstathiou, C.E. [Department of Chemistry, University of Athens, 157 71, Athens (Greece); Prodromidis, M.I., E-mail: mprodrom@cc.uoi.g [Department of Chemistry, University of Ioannina, 45 110, Ioannina (Greece)

    2010-05-30

    The development of a vanadium pentoxide xerogel (VXG)-based sensor for the detection of volatile inorganic (ammonia) and organic (dimethylamine, etc.) amines is described. The xerogel film was deposited on interdigitated gold electrodes by dip-coating using an aqueous solution of VXG. The morphology of the sensing layer, its interaction with ammonia, which was used as a model analyte throughout this work, as well as the regeneration of the surface of the sensor electrodes with vapors of HCl were examined with scanning electron microscopy and FTIR spectroscopy. Signal changes, due to changes of the RC-product of the electrochemical cell (Au-VXG-Au), as a result of its interactions with ammonia vapors, were probed with a portable, homemade charge meter, the Multipulser. Exposing the sensor electrodes to various concentrations of ammonia vapors resulted in proportional changes in the signal output. Finally, the proposed sensors were successfully used for on-site, real-time monitoring of fish spoilage in ambient conditions.

  10. Distributed Energy Resources On-Site Optimization for Commercial Buildings with Electric and Thermal Storage Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Lacommare, Kristina S H; Stadler, Michael; Aki, Hirohisa; Firestone, Ryan; Lai, Judy; Marnay, Chris; Siddiqui, Afzal

    2008-05-15

    The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic as well as environmental attractiveness of on-site generation (e.g., PV, fuel cells, reciprocating engines or microturbines operating with or without CHP) and contribute to enhanced demand response. In order to examine the impact of storage technologies on demand response and carbon emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that has the minimization of annual energy costs as its objective function. By implementing this approach in the General Algebraic Modeling System (GAMS), the problem is solved for a given test year at representative customer sites, such as schools and nursing homes, to obtain not only the level of technology investment, but also the optimal hourly operating schedules. This paper focuses on analysis of storage technologies in DER optimization on a building level, with example applications for commercial buildings. Preliminary analysis indicates that storage technologies respond effectively to time-varying electricity prices, i.e., by charging batteries during periods of low electricity prices and discharging them during peak hours. The results also indicate that storage technologies significantly alter the residual load profile, which can contribute to lower carbon emissions depending on the test site, its load profile, and its adopted DER technologies.

  11. A More Sustainable Way for Producing RC Sandwich Panels On-Site and in Developing Countries

    Directory of Open Access Journals (Sweden)

    Lorenzo Graziani

    2017-03-01

    Full Text Available The purpose of this work is to assess if traditionally used welded connectors for joining the two skins of reinforced concrete (RC sandwich panels, used as structural walls and horizontal structural elements, can be substituted with bent ones. In this way, the scope of the effort is to reduce drastically the energy required during manufacturing, thus having a much more sustainable building product. Wire mesh on site production, in fact, requires a large amount of energy for the welding process, as stated by several Environmental Product Declaration (EPD. In addition, the production of sandwich panels with bent connectors requires a low level of automation and no qualified labor allowing the diffusion in developing countries. The procedures used to execute the work were both experimental and numerical. Structural performances were examined by testing full-scale sandwich panels under (axial and eccentric compression and flexural loads. Additionally, a Finite Element (FE study was developed to investigate and to optimize the dimension of welded mesh and the number of connectors. The major findings show that it is possible to substitute welded connectors with bent ones without compromising the structural performance of the tested RC sandwich panels, thus having a more sustainable way for producing these last ones.

  12. Lightdrum-Portable Light Stage for Accurate BTF Measurement on Site.

    Science.gov (United States)

    Havran, Vlastimil; Hošek, Jan; Němcová, Šárka; Čáp, Jiří; Bittner, Jiří

    2017-02-23

    We propose a miniaturised light stage for measuring the bidirectional reflectance distribution function (BRDF) and the bidirectional texture function (BTF) of surfaces on site in real world application scenarios. The main principle of our lightweight BTF acquisition gantry is a compact hemispherical skeleton with cameras along the meridian and with light emitting diode (LED) modules shining light onto a sample surface. The proposed device is portable and achieves a high speed of measurement while maintaining high degree of accuracy. While the positions of the LEDs are fixed on the hemisphere, the cameras allow us to cover the range of the zenith angle from 0 ∘ to 75 ∘ and by rotating the cameras along the axis of the hemisphere we can cover all possible camera directions. This allows us to take measurements with almost the same quality as existing stationary BTF gantries. Two degrees of freedom can be set arbitrarily for measurements and the other two degrees of freedom are fixed, which provides a tradeoff between accuracy of measurements and practical applicability. Assuming that a measured sample is locally flat and spatially accessible, we can set the correct perpendicular direction against the measured sample by means of an auto-collimator prior to measuring. Further, we have designed and used a marker sticker method to allow for the easy rectification and alignment of acquired images during data processing. We show the results of our approach by images rendered for 36 measured material samples.

  13. Lightdrum—Portable Light Stage for Accurate BTF Measurement on Site

    Directory of Open Access Journals (Sweden)

    Vlastimil Havran

    2017-02-01

    Full Text Available We propose a miniaturised light stage for measuring the bidirectional reflectance distribution function (BRDF and the bidirectional texture function (BTF of surfaces on site in real world application scenarios. The main principle of our lightweight BTF acquisition gantry is a compact hemispherical skeleton with cameras along the meridian and with light emitting diode (LED modules shining light onto a sample surface. The proposed device is portable and achieves a high speed of measurement while maintaining high degree of accuracy. While the positions of the LEDs are fixed on the hemisphere, the cameras allow us to cover the range of the zenith angle from 0 ∘ to 75 ∘ and by rotating the cameras along the axis of the hemisphere we can cover all possible camera directions. This allows us to take measurements with almost the same quality as existing stationary BTF gantries. Two degrees of freedom can be set arbitrarily for measurements and the other two degrees of freedom are fixed, which provides a tradeoff between accuracy of measurements and practical applicability. Assuming that a measured sample is locally flat and spatially accessible, we can set the correct perpendicular direction against the measured sample by means of an auto-collimator prior to measuring. Further, we have designed and used a marker sticker method to allow for the easy rectification and alignment of acquired images during data processing. We show the results of our approach by images rendered for 36 measured material samples.

  14. An Explosion Aftershock Model with Application to On-Site Inspection

    Science.gov (United States)

    Ford, Sean R.; Labak, Peter

    2016-01-01

    An estimate of aftershock activity due to a theoretical underground nuclear explosion is produced using an aftershock rate model. The model is developed with data from the Nevada National Security Site, formerly known as the Nevada Test Site, and the Semipalatinsk Test Site, which we take to represent soft-rock and hard-rock testing environments, respectively. Estimates of expected magnitude and number of aftershocks are calculated using the models for different testing and inspection scenarios. These estimates can help inform the Seismic Aftershock Monitoring System (SAMS) deployment in a potential Comprehensive Test Ban Treaty On-Site Inspection (OSI), by giving the OSI team a probabilistic assessment of potential aftershocks in the Inspection Area (IA). The aftershock assessment, combined with an estimate of the background seismicity in the IA and an empirically derived map of threshold magnitude for the SAMS network, could aid the OSI team in reporting. We apply the hard-rock model to a M5 event and combine it with the very sensitive detection threshold for OSI sensors to show that tens of events per day are expected up to a month after an explosion measured several kilometers away.

  15. Risk-Cost Estimation of On-Site Wastewater Treatment System Failures Using Extreme Value Analysis.

    Science.gov (United States)

    Kohler, Laura E; Silverstein, JoAnn; Rajagopalan, Balaji

    2017-05-01

      Owner resistance to increasing regulation of on-site wastewater treatment systems (OWTS), including obligatory inspections and upgrades, moratoriums and cease-and-desist orders in communities around the U.S. demonstrate the challenges associated with managing risks of inadequate performance of owner-operated wastewater treatment systems. As a result, determining appropriate and enforceable performance measures in an industry with little history of these requirements is challenging. To better support such measures, we develop a statistical method to predict lifetime failure risks, expressed as costs, in order to identify operational factors associated with costly repairs and replacement. A binomial logistic regression is used to fit data from public records of reported OWTS failures, in Boulder County, Colorado, which has 14 300 OWTS to determine the probability that an OWTS will be in a low- or high-risk category for lifetime repair and replacement costs. High-performing or low risk OWTS with repairs and replacements below the threshold of $9000 over a 40-year life are associated with more frequent inspections and upgrades following home additions. OWTS with a high risk of exceeding the repair cost threshold of $18 000 are further analyzed in a variation of extreme value analysis (EVA), Points Over Threshold (POT) where the distribution of risk-cost exceedance values are represented by a generalized Pareto distribution. The resulting threshold cost exceedance estimates for OWTS in the high-risk category over a 40-year expected life ranged from $18 000 to $44 000.

  16. PORTSMOUTH ON-SITE DISPOSAL CELL HIGH DENSITY POLYETHYLENE GEOMEMBRANE LONGEVITY

    Energy Technology Data Exchange (ETDEWEB)

    Phifer, M.

    2012-01-31

    It is anticipated that high density polyethylene (HDPE) geomembranes will be utilized within the liner and closure cap of the proposed On-Site Disposal Cell (OSDC) at the Portsmouth Gaseous Diffusion Plant. The likely longevity (i.e. service life) of HDPE geomembranes in OSDC service is evaluated within the following sections of this report: (1) Section 2.0 provides an overview of HDPE geomembranes, (2) Section 3.0 outlines potential HDPE geomembranes degradation mechanisms, (3) Section 4.0 evaluates the applicability of HDPE geomembrane degradation mechanisms to the Portsmouth OSDC, (4) Section 5.0 provides a discussion of the current state of knowledge relative to the longevity (service life) of HDPE geomembranes, including the relation of this knowledge to the Portsmouth OSDC, and (5) Section 6.0 provides summary and conclusions relative to the anticipated service life of HDPE geomembranes in OSDC service. Based upon this evaluation it is anticipated that the service life of HDPE geomembranes in OSDC service would be significantly greater than the 200 year service life assumed for the OSDC closure cap and liner HDPE geomembranes. That is, a 200 year OSDC HDPE geomembrane service life is considered a conservative assumption.

  17. The attenuation of microorganisms in on-site wastewater effluent discharged into highly permeable subsoils

    Science.gov (United States)

    O'Luanaigh, N. D.; Gill, L. W.; Misstear, B. D. R.; Johnston, P. M.

    2012-11-01

    An extensive field study on percolation areas receiving both septic tank and secondary treated on-site effluents from single houses in Ireland was carried out to investigate the attenuation capacity of highly permeable subsoils with respect to E. coli bacteria and spiked bacteriophages (MS2, ΦX174 and PR772). The development of biomats across the percolation areas receiving the secondary effluent was restricted compared to the percolation area receiving septic tank effluent, promoting a much higher areal hydraulic loading which created significant differences in the potential microbiological loading to groundwater. Greatest E. coli removal in the subsoil occurred within the first 0.35 m of unsaturated subsoil for all effluent types. Analysis showed, however, that more evidence of faecal contamination occurred at depth in the subsoils receiving secondary treated effluents than that receiving septic tank effluent, despite the lower bacterial influent load. All three bacteriophages were reduced to their minimum detection limit (septic tank effluent, although isolated incidences of ΦX174 and PR772 were measured below one trench. However again, slightly higher breakthroughs of MS2 and PR772 contamination were detected at the same depth under the trenches receiving secondary treated effluent.

  18. A C. elegans-based foam for rapid on-site detection of residual live virus.

    Energy Technology Data Exchange (ETDEWEB)

    Negrete, Oscar A.; Branda, Catherine; Hardesty, Jasper O. E. (Sandia National Laboratories, Albuquerque, NM); Tucker, Mark David (Sandia National Laboratories, Albuquerque, NM); Kaiser, Julia N. (Global Product Management, Hilden, Germany); Kozina, Carol L.; Chirica, Gabriela S.

    2012-02-01

    In the response to and recovery from a critical homeland security event involving deliberate or accidental release of biological agents, initial decontamination efforts are necessarily followed by tests for the presence of residual live virus or bacteria. Such 'clearance sampling' should be rapid and accurate, to inform decision makers as they take appropriate action to ensure the safety of the public and of operational personnel. However, the current protocol for clearance sampling is extremely time-intensive and costly, and requires significant amounts of laboratory space and capacity. Detection of residual live virus is particularly problematic and time-consuming, as it requires evaluation of replication potential within a eukaryotic host such as chicken embryos. The intention of this project was to develop a new method for clearance sampling, by leveraging Sandia's expertise in the biological and material sciences in order to create a C. elegans-based foam that could be applied directly to the entire contaminated area for quick and accurate detection of any and all residual live virus by means of a fluorescent signal. Such a novel technology for rapid, on-site detection of live virus would greatly interest the DHS, DoD, and EPA, and hold broad commercial potential, especially with regard to the transportation industry.

  19. Powering up

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    China building the world’s first third-generation nuclear power plants based on American technology Almost 30 years ago, a partial core meltdown occurred in one of the two nuclear reactors at Three Mile llsland Nuclear Generating Station in

  20. Comic Power

    DEFF Research Database (Denmark)

    Tønder, Lars

    2014-01-01

    by skepticism about the enduring contributions of comic acts, and it then goes on to suggest that we turn to an alternative trajectory in democratic theory, one that encourages us to focus on the empowering and pluralizing potential embedded in what I name “comic power.” The wager is that attention...

  1. Power Play

    Institute of Scientific and Technical Information of China (English)

    BRADLEY GARDNER

    2008-01-01

    @@ Bill Emmott's new book,Rivals:How the Power Struggle Between China,India and Japan Will Shape Our Next Decade,is an investigation of the problematic relationship between China,India,and Japan,as two of those countries begin to assert themselves on the world stage,and how the situation could result in all-out conflict.

  2. Power Talk

    DEFF Research Database (Denmark)

    Stefanovic, Cedomir; Popovski, Petar; Angjelichinoski, Marko

    2015-01-01

    , while it is received by processing the bus measurements that units perform. This implies that the communication does not require a dedicated modem, but instead it is piggybacked on top of the power electronics. The communication is challenged by the random fluctuations of the voltage level due...

  3. Power semiconductors

    CERN Document Server

    Kubát, M

    1984-01-01

    The book contains a summary of our knowledge of power semiconductor structures. It presents first a short historic introduction (Chap. I) as well as a brief selection of facts from solid state physics, in particular those related to power semiconductors (Chap. 2). The book deals with diode structures in Chap. 3. In addition to fundamental facts in pn-junction theory, the book covers mainly the important processes of power structures. It describes the emitter efficiency and function of microleaks (shunts). the p +p and n + n junctions, and in particular the recent theory of the pin, pvn and p1tn junctions, whose role appears to be decisive for the forward mode not only of diode structures but also of more complex ones. For power diode structures the reverse mode is the decisive factor in pn-junction breakdown theory. The presentation given here uses engineering features (the multiplication factor M and the experimentally detected laws for the volume and surface of crystals), which condenses the presentation an...

  4. POWER FUNCTIONS

    Institute of Scientific and Technical Information of China (English)

    王雷

    2008-01-01

    <正>A power function of degree n is a function of the form f(x)=ax~n.For large n,it appears that the graph coincide with the x-axis near the origin,but it does not;the graph actually touches the x—axis only at the origin.

  5. Power Shift

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    @@ "We are entering a new era of world history: the end of Western domination and the arrival of the Asian century. The question is: will Washington wake up to this reality?" This is the central premise of Kishore Mahbubani's provocative new book The New Asian Hemisphere: The Irresistible Shift of Global Power to the East.

  6. Power branding

    Energy Technology Data Exchange (ETDEWEB)

    Chambers, A.

    1998-12-31

    For most of its century-long history, electricity was a natural monopoly, due in part to the excessive cost of the necessary infrastructure. In the past decade, however, politics have pushed the industry toward competition and consumer choice. At the same time, technology has been developed that allows consumers to choose their electricity supplier and to track the flow of power through the various grids and lines. In her new book, Power Branding, author and industry expert Ann Chambers examines marketing and branding of electricity -- what it is, how it`s done, what its benefits are for electric utilities, marketers, and even natural gas companies allied with the utilities. She surveys industry leaders who have already taken a dive into the ocean of marketing and offers lessons drawn from their experiences. She also takes a look at other formerly regulated industries -- airlines, telephone, natural gas -- and describes how their rebirth as free-market industries may affect the course of the electric utility industry`s experience. The contents include: Introduction; Basics of branding: Brand image; Value-added services; Southern Company; Duke Energy; UtiliCorp/EnergyOne/Aquila--big and brand; Engage energy; Florida Power and Light Co.; Enron; Convergence; Lessons from the natural gas industry; Lessons from other industries; Conclusion; Resources; Glossary of branding, marketing and Btu convergence; and Major federal legislation affecting the electric power industry.

  7. Grid-Tied Photovoltaic Power System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2011-01-01

    A grid-tied photovoltaic (PV) power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. Operating costs of a PV power system are low compared to conventional power technologies. This method can displace the highest-cost electricity during times of peak demand in most climatic regions, and thus reduce grid loading. Net metering is often used, in which independent power producers such as PV power systems are connected to the utility grid via the customers main service panels and meters. When the PV power system is generating more power than required at that location, the excess power is provided to the utility grid. The customer pays the net of the power purchased when the on-site power demand is greater than the onsite power production, and the excess power is returned to the utility grid. Power generated by the PV system reduces utility demand, and the surplus power aids the community. Modern PV panels are readily available, reliable, efficient, and economical, with a life expectancy of at least 25 years. Modern electronics have been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy equal to the modern PV panels. The grid-tied PV power system was successfully designed and developed, and this served to validate the basic principles developed, and the theoretical work that was performed. Grid-tied PV power systems are reliable, maintenance- free, long-life power systems, and are of significant value to NASA and the community. Of particular value are the analytical tools and capabilities that have been successfully developed. Performance predictions can be made confidently for grid-tied PV systems of various scales. The work was done under the NASA Hybrid Power Management (HPM

  8. Progress and prospects for phosphoric acid fuel cell power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bonville, L.J.; Scheffler, G.W.; Smith, M.J. [International Fuel Cells Corp., South Windsor, CT (United States)

    1996-12-31

    International Fuel Cells (IFC) has developed the fuel cell power plant as a new, on-site power generation source. IFC`s commercial fuel cell product is the 200-kW PC25{trademark} power plant. To date over 100 PC25 units have been manufactured. Fleet operating time is in excess of one million hours. Individual units of the initial power plant model, the PC25 A, have operated for more than 30,000 hours. The first model {open_quotes}C{close_quotes} power plant has over 10,000 hours of operation. The manufacturing, application and operation of this power plant fleet has established a firm base for design and technology development in terms of a clear understanding of the requirements for power plant reliability and durability. This fleet provides the benchmark against which power plant improvements must be measured.

  9. New advanced electrochemical techniques for on site measurements of reinforcement corrosion

    Directory of Open Access Journals (Sweden)

    Andrade, C.

    2001-12-01

    Full Text Available Measurement techniques of reinforcement corrosion are scarcely researched if compared with the increasing number of publications in the subject. However, numerous possibilities and challenges remain without being explored. In present paper mention is made to some of the present possibilities of electrochemical techniques, either on-site or in the laboratory. Concerning on-site techniques it is commented the possibilities and limitations of present methods of measuring Polarization Resistance, Rp. Particular attention is given to the need to use a modulated guardring with sensors controlling this modulation to obtain accurate values of the corrosion rate. After, description of the basis of new techniques related to the measurements of the passivation state in cathodically protected structures, is made. The basis of a new method of measuring corrosion without the need to touch the metal is also presented. Regarding the use of embedded sensors, the experience until now shows the difficulty of interpretation of the data collected, due to the important influence of ambient temperature. Finally, some comments are presented on the need of joint work of material and structural specialists.

    Las técnicas de medida de la corrosión en hormigón armado se investigan muy poco en comparación con el creciente número de publicaciones sobre este tema. Sin embargo, existen muchas posibilidades y retos que todavía no han sido exploradas. En el presente artículo se descubren algunas de las presentes posibilidades de las técnicas electroquímicas, tanto in-situ como en laboratorio. En cuanto a las técnicas in situ se refiere, se comentan las posibilidades y limitaciones de los métodos actuales de medida de la Resistencia de Polarización, Rp. Se presta particular atención ante la necesidad de utilizar un anillo de guarda modulado con sensores que controlen esta modulación para obtener valores adecuados de velocidad de corrosión. Después se

  10. ADVANTAGES AND DISADVANTAGES TO OPERATING AN ON-SITE LABORATORY AT THE SANDIA NATIONAL LABORATORIES CHEMICAL WASTE LANDFILL

    Energy Technology Data Exchange (ETDEWEB)

    Young, S.G.; Creech, M.N.

    2003-02-27

    During the excavation of the Sandia National Laboratories, New Mexico (SNL/NM) Chemical Waste Landfill (CWL), operations were realized by the presence of URS' (formerly known as United Research Services) On-site Mobile Laboratory (OSML) and the close proximity of the SNL/NM Environmental Restoration Chemical Laboratory (ERCL). The laboratory was located adjacent to the landfill in order to provide soil characterization, health and safety support, and waste management data. Although the cost of maintaining and operating an analytical laboratory can be higher than off-site analysis, there are many benefits to providing on site analytical services. This paper describes the synergies between the laboratory, as well as the advantages and disadvantages to having a laboratory on-site during the excavation of SNL/NM CWL.

  11. OSIRIS—Gamma-ray spectroscopy software for on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty

    Energy Technology Data Exchange (ETDEWEB)

    Caffrey, A.J., E-mail: Gus.Caffrey@inl.gov [Idaho National Laboratory, Idaho Falls, ID (United States); Bowyer, T.W. [Pacific Northwest National Laboratory, Richland, WA (United States); Egger, A.E. [Idaho National Laboratory, Idaho Falls, ID (United States); Hall, J.C. [Pacific Northwest National Laboratory, Richland, WA (United States); Kelly, S.M.; Krebs, K.M. [Idaho National Laboratory, Idaho Falls, ID (United States); Kreek, S.A. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Jordan, D.V.; Milbrath, B.D. [Pacific Northwest National Laboratory, Richland, WA (United States); Padgett, S.W. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Wharton, C.J. [Idaho National Laboratory, Idaho Falls, ID (United States); Wimer, N.G. [Lawrence Livermore National Laboratory, Livermore, CA (United States)

    2015-06-01

    We have designed and tested software for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—OSIRIS—software filters the spectral data to display only radioisotopic information relevant to CTBT on-site inspections, e.g.,{sup 131}I. A set of over 100 fission-product spectra was employed for OSIRIS testing. These spectra were measured where possible, or generated by modeling. The test spectral compositions include non-nuclear-explosion scenarios, e.g., a severe nuclear reactor accident, and nuclear-explosion scenarios such as a vented underground nuclear test. Comparing its computer-based analyses to expert visual analyses of the test spectra, OSIRIS correctly identifies CTBT-relevant fission product isotopes at the 95% level or better.

  12. Residential on site solar heating systems: a project evaluation using the capital asset pricing model

    Energy Technology Data Exchange (ETDEWEB)

    Schutz, S.R.

    1978-12-01

    An energy source ready for immediate use on a commercial scale is solar energy in the form of On Site Solar Heating (OSSH) systems. These systems collect solar energy with rooftop panels, store excess energy in water storage tanks and can, in certain circumstances, provide 100% of the space heating and hot water required by the occupants of the residential or commercial structure on which the system is located. Such systems would take advantage of a free and inexhaustible energy source--sunlight. The principal drawback of such systems is the high initial capital cost. The solution would normally be a carefully worked out corporate financing plan. However, at the moment it is individual homeowners and not corporations who are attempting to finance these systems. As a result, the terms of finance are excessively stringent and constitute the main obstacle to the large scale market penetration of OSSH. This study analyzes the feasibility of OSSH as a private utility investment. Such systems would be installed and owned by private utilities and would displace other investment projects, principally electric generating plants. The return on OSSH is calculated on the basis of the cost to the consumer of the equivalent amount of electrical energy that is displaced by the OSSH system. The hurdle rate for investment in OSSH is calculated using the Sharpe--Lintner Capital Asset Pricing Model. The results of this study indicate that OSSH is a low risk investment having an appropriate hurdle rate of 7.9%. At this rate, OSSH investment appears marginally acceptable in northern California and unambiguously acceptable in southern California. The results also suggest that utility investment in OSSH should lead to a higher degree of financial leverage for utility companies without a concurrent deterioration in the risk class of utility equity.

  13. The CTBT's International Monitoring System and On-Site Inspection Capabilities: a Status Report

    Science.gov (United States)

    Zerbo, Lassina

    2017-01-01

    At its 20th anniversary the Comprehensive Nuclear-Test-Ban Treaty has now gathered 183 State Signatories, of which 166 have ratified. But 8 States remain to ratify before we reach entry into force. In the meantime the CTBT verification regime has accumulated two decades worth of experience, and has achieved proven results. The regime includes a global system for monitoring the earth, the oceans and the atmosphere and an on-site inspection (OSI) capability. It uses seismic, hydroacoustic, infrasound and radionuclide technologies to do so. More than 90% of the 337 facilities of the International Monitoring System (IMS) have been installed and are sending data to the International Data Centre (IDC) in Vienna, Austria for processing. These IMS data along with IDC processed and reviewed products are available to all States that have signed the Treaty. The monitoring system has been put to test and demonstrated its effectiveness by detecting, locating and reporting on the DPRK announced nuclear tests in 2006, 2009, 2013 and twice in 2016. In addition to detecting radioxenon consistent with the nuclear tests in 2006 and 2013 the IMS radionuclide network also added value in the response to the tragic events in Fukushima in 2011. We continue to find new civil and scientific applications of the IMS that are made available to the international community to deal with major societal issues such as sustainable development, disaster risk reduction and climate change. OSI capabilities continue to be developed and tested. The Integrated Field Exercise in Jordan in 2014 demonstrated that they have reached a high level of operational readiness. The CTBT has been a catalyst for the development of new scientific fields in particular in the noble gas monitoring technology. CTBTO seeks to continuously improve its technologies and methods through interaction with the scientific community.

  14. Using on-site liver 3-D reconstruction and volumetric calculations in split liver transplantation

    Institute of Scientific and Technical Information of China (English)

    Trevor W Reichman; Brittan Y Fiorello; Ian Carmody; Humberto Bohorquez; Ari Cohen; John Seal; David Bruce; George E Loss

    2016-01-01

    BACKGROUND: Split liver transplantation increases the number of grafts available for transplantation. Pre-recovery assessment of liver graft volume is essential for selecting suit-able recipients. The purpose of this study was to determine the ability and feasibility of constructing a 3-D model to aid in surgical planning and to predict graft weight prior to anin situ division of the donor liver. METHODS: Over 11 months, 3-D volumetric reconstruction of 4 deceased donors was performed using Pathifnder Scout© liver volumetric software. Demographic, laboratory, operative, perioperative and survival data for these patients along with donor demographic data were collected prospectively and analyzed retrospectively. RESULTS: The average predicted weight of the grafts from the adult donors obtained from anin situ split procedure were 1130 g (930-1458 g) for the extended right lobe donors and 312 g (222-396 g) for left lateral segment grafts. Actual adult graft weight was 92% of the predicted weight for both the ex-tended right grafts and the left lateral segment grafts. The pre-dicted and actual graft weights for the pediatric donors were 176 g and 210 g for the left lateral segment grafts and 308 g and 280 g for the extended right lobe grafts, respectively. All grafts were transplanted except for the right lobe from the pediatric donors due to the small graft weight. CONCLUSIONS: On-site volumetric assessment of donors provides useful information for the planning of anin situ split and for selection of recipients. This information may expand the donor pool to recipients previously felt to be unsuitable due to donor and/or recipient weight.

  15. Balloon Coating with Rapamycin Using an On-site Coating Device

    Energy Technology Data Exchange (ETDEWEB)

    Schmehl, Joerg, E-mail: joerg.schmehl@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen (Germany); Ruhr, Juergen von der [Institute of Anatomy, University of Tuebingen (Germany); Dobratz, Markus; Kehlbach, Rainer [Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen (Germany); Braun, Isabelle [Translumina GmbH (Germany); Greiner, Tim-Oliver [Clinic of Thoracic and Cardiovascular Surgery, University Hospital of Tuebingen (Germany); Claussen, Claus D. [Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen (Germany); Behnisch, Boris [Translumina GmbH (Germany)

    2013-06-15

    Purpose. The efficacy of drug-eluting balloons has been demonstrated in clinical trials. The drug predominantly used is paclitaxel because of its lipophilic properties and the rapid onset of action. The aim of the investigation was to evaluate the feasibility and efficacy of an alternative balloon coating with rapamycin that can be applied on site.MethodsThe balloon coating (3.0/18 and 3.0/12 mm, Cathy No. 4, Translumina GmbH) with rapamycin was conducted with a coating machine (Translumina GmbH). Concentrations were 2, 2 Multiplication-Sign 2, 3, and 4 %. Measurements regarding the amount of substance released to the vessel wall were carried out on explanted porcine coronaries by means of ultraviolet and visible-light spectroscopy. Inflation time varied between 30 and 120 s. The biological effect of the coating was evaluated in a porcine peripheral overstretch and stent implantation model. Results. The amount of rapamycin on the balloon surface ranged from 558 {+-} 108 {mu}g for the 2 % solution to 1,441 {+-} 228 {mu}g in the 4 % solution. An amount of 95 {+-} 63-193 {+-} 113 {mu}g was released into the vessel wall. The quantitative measurements of the angiographic examinations 4 weeks after treatment revealed a reduction of diameter stenosis from 20.6 {+-} 17.4 % in the control group to 11.6 {+-} 5.5 % in the drug-eluting balloon group. Conclusion. A balloon coating with rapamycin omitting an excipient is possible with a dose-adjustable coating machine. However, the biological effects are moderate, which make further optimization of the coating process and evaluation of appropriate excipients necessary.

  16. Modeling effluent distribution and nitrate transport through an on-site wastewater system.

    Science.gov (United States)

    Hassan, G; Reneau, R B; Hagedorn, C; Jantrania, A R

    2008-01-01

    Properly functioning on-site wastewater systems (OWS) are an integral component of the wastewater system infrastructure necessary to renovate wastewater before it reaches surface or ground waters. There are a large number of factors, including soil hydraulic properties, effluent quality and dispersal, and system design, that affect OWS function. The ability to evaluate these factors using a simulation model would improve the capability to determine the impact of wastewater application on the subsurface soil environment. An existing subsurface drip irrigation system (SDIS) dosed with sequential batch reactor effluent (SBRE) was used in this study. This system has the potential to solve soil and site problems that limit OWS and to reduce the potential for environmental degradation. Soil water potentials (Psi(s)) and nitrate (NO(3)) migration were simulated at 55- and 120-cm depths within and downslope of the SDIS using a two-dimensional code in HYDRUS-3D. Results show that the average measured Psi(s) were -121 and -319 cm, whereas simulated values were -121 and -322 cm at 55- and 120-cm depths, respectively, indicating unsaturated conditions. Average measured NO(3) concentrations were 0.248 and 0.176 mmol N L(-1), whereas simulated values were 0.237 and 0.152 mmol N L(-1) at 55- and 120-cm depths, respectively. Observed unsaturated conditions decreased the potential for NO(3) to migrate in more concentrated plumes away from the SDIS. The agreement (high R(2) values approximately 0.97) between the measured and simulated Psi(s) and NO(3) concentrations indicate that HYDRUS-3D adequately simulated SBRE flow and NO(3) transport through the soil domain under a range of environmental and effluent application conditions.

  17. Balloon coating with rapamycin using an on-site coating device.

    Science.gov (United States)

    Schmehl, Jörg; von der Ruhr, Jürgen; Dobratz, Markus; Kehlbach, Rainer; Braun, Isabelle; Greiner, Tim-Oliver; Claussen, Claus D; Behnisch, Boris

    2013-06-01

    The efficacy of drug-eluting balloons has been demonstrated in clinical trials. The drug predominantly used is paclitaxel because of its lipophilic properties and the rapid onset of action. The aim of the investigation was to evaluate the feasibility and efficacy of an alternative balloon coating with rapamycin that can be applied on site. The balloon coating (3.0/18 and 3.0/12 mm, Cathy No. 4, Translumina GmbH) with rapamycin was conducted with a coating machine (Translumina GmbH). Concentrations were 2, 2 × 2, 3, and 4 %. Measurements regarding the amount of substance released to the vessel wall were carried out on explanted porcine coronaries by means of ultraviolet and visible-light spectroscopy. Inflation time varied between 30 and 120 s. The biological effect of the coating was evaluated in a porcine peripheral overstretch and stent implantation model. The amount of rapamycin on the balloon surface ranged from 558 ± 108 μg for the 2 % solution to 1,441 ± 228 μg in the 4 % solution. An amount of 95 ± 63-193 ± 113 μg was released into the vessel wall. The quantitative measurements of the angiographic examinations 4 weeks after treatment revealed a reduction of diameter stenosis from 20.6 ± 17.4 % in the control group to 11.6 ± 5.5 % in the drug-eluting balloon group. A balloon coating with rapamycin omitting an excipient is possible with a dose-adjustable coating machine. However, the biological effects are moderate, which make further optimization of the coating process and evaluation of appropriate excipients necessary.

  18. Portable, fully autonomous, ion chromatography system for on-site analyses.

    Science.gov (United States)

    Elkin, Kyle R

    2014-07-25

    The basic operating principles of a portable, fully autonomous, ion chromatography system are described. The system affords the user the ability to collect and analyze samples continuously for 27 days, or about 1930 injections before needing any user intervention. Within the 13 kg system, is a fully computer controlled autosampling, chromatography and data acquisition system. An eluent reflux device (ERD), which integrates eluent suppression and generation in a single multi-chambered device, is used to minimize eluent consumption. During operation, about 1 μL of water per minute is lost to waste while operating standard-bore chromatography at 0.5 mL min(-1) due to eluent refluxing. Over the course of 27 days, about 100mL of rinse water is consumed, effectively eliminating waste production. Data showing the reproducibility (below 1% relative standard deviation over 14 days) of the device is also presented. Chromatographic analyses of common anions (Cl(-), NO3(-), SO4(2-), PO4(3-)), is accomplished in under 15 min using a low backpressure guard column with ∼ 25 mM KOH isocratic elution. For detection, a small capacitively-coupled contactless conductivity detector (C4D) is employed, able to report analytes in the sub to low micromolar range. Preconcentration of the injected samples gives a 50-fold decrease in detection limits, primarily utilized for in-situ detection of phosphate (LOQ 10 μg L(-1)). Field analyses are shown for multiple on-site analyses of stream water indifferent weather conditions. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Poultry power

    Energy Technology Data Exchange (ETDEWEB)

    Loram, G.

    2000-02-01

    This article gives details of the world's largest power plant fired by poultry litter and forestry waste fired in Thetford, UK. The processing of the waste, the injection of the waste by air, the plant operation, and the cleaning of the flue gas are described. The low levels of odour and noise, and the environmental benefits of the plant which produces no methane or carbon dioxide emissions are noted. (uk)

  20. Cyber Power

    Science.gov (United States)

    2010-05-01

    attributed to “patriotic hackers” in Russia who were offended by Estonia’s movement of a World War II monument to Soviet soldiers. In 2008, shortly...internet to mobilize Chinese students to demonstrate against Japan when its officials took positions that offended Chinese views of the 1930s...reduction of power differentials among them. Anyone from a teen age hacker to a major modern government can do damage in cyber space, and as the famous New

  1. Suntech Power

    Institute of Scientific and Technical Information of China (English)

    BRAKLEY GARDNER

    2008-01-01

    @@ Why the new US president could provide a boost for China's largest solar firm Back in the glory days of China investing, Suntech Power (尚德太阳能电力), China's largest solar com-pany, benefited from both inves-tor interest during China's stock market boom, and the growing demand for solar technologies worldwide, as governments be-gan implementing a raft of new measures providing assistance to renewable energy companies.

  2. BRICS Power

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    When Goldman Sachs economist Jim O’Neill coined the acronym BRIC to describe collectively Brazil,Russia,India and China,the world mainly regarded it as one of the easy-come,easy-go terms in economics.A decade later,O’Neill’s concept is not forgotten.It is successfully playing an historic role in representing the shift in global economic power away

  3. A preliminary design and BOP cost analysis of M-C Power`s MCFC commerical unit

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T.P. [Bechtel Corp, San Francisco, CA (United States)

    1996-12-31

    M-C Power Corporation plans to introduce its molten carbonate fuel cell (MCFC) market entry unit in the year 2000 for distributed and on-site power generation. Extensive efforts have been made to analyze the cell stack manufacturing costs. The major objective of this study is to conduct a detailed analysis of BOP costs based on an initial design of the market entry unit.

  4. The Potential in Water Supply and Sanitation Services of the On Site Production of Sodium Hypochlorite (OSEC Driven by PV Solar Source

    Directory of Open Access Journals (Sweden)

    Andrea Micangeli

    2013-12-01

    Full Text Available This study aims at evaluating the impact of an On Site Electro Chlorination (OSEC device, a system for the sodium hypochlorite production, on the improvement of health and hygienic standards in Mesoamerica focusing on Chiapas-Mexico and Costa Rica, as well as in Africa, Western Sahara (Refugees Camp and Tanzania. The threat of infectious diseases and the importance of cleaned and treated water with the consequent high impact on the vulnerable population have been studied in each of the above countries. In this framework the production of low cost sodium hypochlorite through a stand-alone system powered by PV solar source could be a good starting point in improving sanitation conditions, assuring the disinfection of water and clothes, and improve food safety. The cost analysis shows that producing sodium hypochlorite with an OSEC solar system could lead to 10 to 15 times saving with respect to the purchasing of it at market price, above all in developing countries. Furthermore, the LCA study highlights the low environmental impact of the on-site production of sodium hypochlorite through qualitative and quantitative data that demonstrate how this system has pollutant emissions from 14 to 56 times lower than the equivalent industrial process (N factor. The paper describes as well possible practical applications of the sodium hypochlorite in the African and Latin American context. Additionally, it demonstrates the potential to create an impact on the social context and microenterprises specialised in the production of hygiene and sanitation products, managed by local people selling at affordable prices and reaching the poorest villages of developing countries.

  5. The Cherenkov Telescope array on-site integral sensitivity: observing the Crab

    Science.gov (United States)

    Fioretti, Valentina; Bulgarelli, Andrea; Schüssler, Fabian

    2016-07-01

    The Cherenkov Telescope Array (CTA) is the future large observatory in the very high energy (VHE) domain. Operating from 20 GeV to 300 TeV, it will be composed of tens of Imaging Air Cherenkov Telescopes (IACTs) displaced in a large area of a few square kilometers in both the southern and northern hemispheres. Thanks to the wide energy coverage and the tremendous boost in effective area (10 times better than the current IACTs), for the first time a VHE observatory will be able to detect transient phenomena in short exposures. The CTA/DATA On-Site Analysis (OSA) is the system devoted to the development of dedicated pipelines and algorithms to be used at the CTA site for the reconstruction, data quality monitoring, science monitoring and realtime science alerting during observations. The minimum exposure required to issue a science alert is not a general requirement of the observatory but is a function of the astrophysical object under study, because the ability to detect a given source is determined by the integral sensitivity which, in addition to the CTA Monte Carlo simulations, providing the energy-dependent instrument response (e.g. the effective area and the background rate), requires the spectral distribution of the science target. The OSA integral sensitivity is computed here for the most studied source at Gamma-rays, the Crab Nebula, for a set of exposures ranging from 1000 seconds to 50 hours, using the full CTA Southern array. The reason for the Crab Nebula selection as the first example of OSA integral sensitivity is twofold: (i) this source is characterized by a broad spectrum covering the entire CTA energy range; (ii) it represents, at the time of writing, the standard candle in VHE and it is often used as unit for the IACTs sensitivity. The effect of different Crab Nebula emission models on the CTA integral sensitivity is evaluated, to emphasize the need for representative spectra of the CTA science targets in the evaluation of the OSA use cases. Using

  6. Evaluation of snow-glide risk by modelling and on-site assessment

    Science.gov (United States)

    Leitinger, Georg; Meusburger, Katrin; Rüdisser, Johannes; Tasser, Erich; Höller, Peter

    2015-04-01

    Abandonment of agricultural practices on alpine grasslands lead to increasing snow-glide intensities due to lower surface roughness of the vegetation. Beneath the danger of snow-glide avalanches snow gliding leads to soil erosion and damaging of young trees at afforested sites. Especially in high altitudes afforestation is important to protect settlements and infrastructure against snow-gliding and glide avalanches. Snow-glide damages are therefore of particular danger for these afforestation sites. In the light of future climate change and warmer winter periods, studies already state increasing snow-glide risk and the occurrence of glide avalanches. This study presents an approach to evaluate snow-glide risk by combining the refined Spatial Snow Glide Model (SSGM) first published by Leitinger et al. (2008) and the Guidelines to Identify Snow-Glide Areas (GISGA) proposed by Höller (2012), an on-site risk analyses approach. First, GISGA was validated on the basis of corresponding snow-glide measurements. Second, a potential snow-glide map for an area in the Eastern Alps covering 20000 km² was modelled. The results revealed considerable areas of high snow-glide risk. Using the average amount of winter precipitation between 1990 and 2010 in the SSGM shows higher vulnerability for the northern part of the study area (Tyrol, Austria) than in the southern part (South Tyrol, Italy) because of lower winter precipitation. However, running the SSGM based on the highest winter precipitation registered in the study area between 1801 and 2003 exhibits the possibility of very high snow-glide risk for most parts of the study area with significant increasing risk in the southern part. Given the very probable future climate during winter periods with increasing temperatures but uncertain development of precipitation patterns, snow-glide activity and linked glide avalanches might further increase at least in areas and altitudes with solid precipitation. In combination with the

  7. A Threshold-based, on-site earthquake early warning approach for Italy

    Science.gov (United States)

    Caruso, Alessandro; Colombelli, Simona; Zollo, Aldo; Kanamori, Hiroo

    2017-04-01

    A real-time strategy for a P-wave based, on-site earthquake early warning system has been developed and tested using the database of Italian earthquakes. The key elements of the proposed methodology are: 1) the real-time, continuous measurement of three peak amplitude parameters (the initial peak of displacement, Pd, velocity, Pv, and acceleration, Pa) along the vertical component of the P-wave signal and 2) their empirical combination to predict the ensuing Peak Ground Velocity at the same site. The observed parameters are compared to prior established threshold values and then converted into a single, dimensionless variable. A local alert level is issued at the recording site as soon as the empirical combination overcomes a given threshold. The three parameters are continuously measured along the recorded signals, starting from the P-wave arrival time, and progressively expanding the time window. A possible risk when using this approach is the inclusion of the S-waves in the analyzed P-wave signal portion, which may lead to an overestimation of the predicted ground shaking level. To minimize the S-wave contamination, an efficient algorithm for the automatic detection of the S-wave arrival time has been included. The algorithm is based on the real-time polarization analysis of the three-component seismogram and on the Singular Value Decomposition (SVD) (Rosenberger, 2010; Amoroso et al., 2012) and is able to distinguish variations in the polarization of the original signal, and to discriminate the dominant P-wave signal from the arrival of later S-wave phases. The performance of the method has been evaluated by defining successful, missed and false alarms, and counting the relative percentage, after applying the approach to a testing catalog of Italian earthquake records. The database we used for the system testing and calibration consists of more than 200 Italian events in a magnitude range 3.5 SVD filtering. The proposed methodology provides more reliable

  8. Comparative study of the microbial quality of greywater treated by three on-site treatment systems.

    Science.gov (United States)

    Friedler, E; Kovalio, R; Ben-Zvi, A

    2006-06-01

    This paper analyses the performance of a pilot scale treatment plant, treating light domestic greywater. The treatment included three parallel treatment units: stand-alone sand filtration (SFEB), RBC followed by sand filtration (SFRBC), and an MBR equipped with UF membranes (MBR). The performance of the SFEB unit was rather poor. The RBC and MBR units produced effluent of excellent quality, with COD of 42 and 40 mg l(-1), BOD of 1.8 and 1.1 mg l(-1), and turbidity of 0.6 and 0.2 NTU respectively. The SFEB failed to remove heterotrophic microorganisms (HPC), while the SFRBC and the MBR exhibited 2.1 and 3.6 logs removal, leading to effluent concentrations of 1.1 x 10(3) and 8.8 x 10(3) cfu ml(-1) respectively. Faecal coliforms (FC) counts were 3.4 x 10(5) 1.4 x 10(5) 1.1 x 10(3) and 3.5 x 10(2) cfu 100 ml(-1) in raw greywater, and in the SFEB, SFRBC and MBR effluents respectively. Further, in 60% of the samples no FC were detected in the MBR effluent. In order to simulate residence times in full scale systems, effluents were disinfected and stored for 0.5 h, 3 h, 6 h (normal operation), and one week (extreme event). The average chlorine demand was 8.1, 3.8 and 2.9 mg l(-1) for SFEB, SFRBC and MBR effluents respectively. Low residual chlorine (0.15-0.22 mg l(-1)) remained in all effluents even after a week-long storage. Disinfection reduced HPC by 5, 2 and 2 orders of magnitude in the SFEB, SFRBC and MBR effluents respectively, with no regrowth in short contact times (up to 6 hours). Some regrowth was observed after a week-long storage leading to 10(6), 10(4) and 10(3) cfu ml(-1) (SFEB SFRBC and MBR respectively). Disinfection reduced FC counts in all three types of effluent to 0 cfu 100 ml(-1), whilst no FC regrowth was observed after week-long storage. The results show that both RBC and MBR treatment units are viable options for on-site greywater reuse. The disinfection experiments strongly indicate that the health risk associated with the reuse of these effluents

  9. Dynamic telecytopathology of on site rapid cytology diagnoses for pancreatic carcinoma

    Directory of Open Access Journals (Sweden)

    Kim Burton

    2006-12-01

    Full Text Available Abstract Background Diagnosis of pancreatic lesions can be accurately performed by endoscopic ultrasound guided fine needle aspiration (EUS-FNA with onsite cytopathologists to assess specimen adequacy and to determine a preliminary diagnosis. Considerable time is needed to perform on-site assessments. This takes away work time of cytopathologists and prohibits them from serving remote locations. It is therefore logical to ask if real-time telecytopathology could be used to assess specimen adequacy and if telecytopathology diagnosis has the same level of agreement to the final diagnosis as that of onsite evaluation. In this study, we compare agreement between cytodiagnoses rendered using telecytopathology with onsite and final interpretations. Method 40 Diff-Quik-stained EUS-FNA were re-evaluated retrospectively (patient ages 31–62, 19:21 male:female, 15 non-malignant lesions, 25 malignant lesions as classified by final diagnosis. Each previously assessed by a cytopathologist and finally reviewed by the same or different cytopathologist. Blinded to the final diagnosis, a resident pathologist re-screened all slides for each case, selected a slide and marked the diagnostic cells most representative of the lesion. Blinded to the diagnosis, one cytopathologist assessed the marked cells through a real time remotely operated telecytopathology system (MedMicroscopy. Diagnosis and time spent were recorded. Kappa statistic was used to compare agreements between telecytopathology vs. original onsite vs. final diagnoses. Results Time spent for prescreening ranged from 1 to 5 minutes (mean 2.6 +/- 1.3 minutes and time spent for telecytopathology diagnosis ranged from 2–20 minutes (mean 7.5 +/- 4.5 minutes. Kappa statistics, K, was as follows: telecytopathology versus onsite diagnosis K, 95% CI = 0.65, 0.41–0.88, for telecytopathology versus final K, 95% CI = 0.61, 0.37–0.85 and for onsite diagnosis versus final K, 95% CI = 0.79, 0.61–0.98. There is

  10. ALL-PATHWAYS DOSE ANALYSIS FOR THE PORTSMOUTH ON-SITE WASTE DISPOSAL FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Smith, F.; Phifer, M.

    2014-04-10

    A Portsmouth On-Site Waste Disposal Facility (OSWDF) All-Pathways analysis has been conducted that considers the radiological impacts to a resident farmer. It is assumed that the resident farmer utilizes a farm pond contaminated by the OSWDF to irrigate a garden and pasture and water livestock from which food for the resident farmer is obtained, and that the farmer utilizes groundwater from the Berea sandstone aquifer for domestic purposes (i.e. drinking water and showering). As described by FBP 2014b the Hydrologic Evaluation of Landfill Performance (HELP) model (Schroeder et al. 1994) and the Surface Transport Over Multiple Phases (STOMP) model (White and Oostrom 2000, 2006) were used to model the flow and transport from the OSWDF to the Points of Assessment (POAs) associated with the 680-ft elevation sandstone layer (680 SSL) and the Berea sandstone aquifer. From this modeling the activity concentrations radionuclides were projected over time at the POAs. The activity concentrations were utilized as input to a GoldSimTM (GTG 2010) dose model, described herein, in order to project the dose to a resident farmer over time. A base case and five sensitivity cases were analyzed. The sensitivity cases included an evaluation of the impacts of using a conservative inventory, an uncased well to the Berea sandstone aquifer, a low waste zone uranium distribution coefficient (Kd), different transfer factors, and reference person exposure parameters (i.e. at 95 percentile). The maximum base case dose within the 1,000 year assessment period was projected to be 1.5E-14 mrem/yr, and the maximum base case dose at any time less than 10,000 years was projected to be 0.002 mrem/yr. The maximum projected dose of any sensitivity case was approximately 2.6 mrem/yr associated with the use of an uncased well to the Berea sandstone aquifer. This sensitivity case is considered very unlikely because it assumes leakage from the location of greatest concentration in the 680 SSL in to the

  11. Thyroid fine needle aspiration biopsy: Do we really need an on-site cytopathologist?

    Energy Technology Data Exchange (ETDEWEB)

    Cengic, Ismet, E-mail: ismetcengic@yahoo.com [Department of Radiology, Marmara University, School of Medicine, Fevzi Cakmak Mahallesi Mimar Sinan Caddesi No: 41, 34899 Ust Kaynarca Pendik, Istanbul (Turkey); Tureli, Derya, E-mail: deryatureli@yahoo.com [Department of Radiology, Marmara University, School of Medicine, Fevzi Cakmak Mahallesi Mimar Sinan Caddesi No: 41, 34899 Ust Kaynarca Pendik, Istanbul (Turkey); Ahiskali, Rengin, E-mail: renginiara@gmail.com [Department of Pathology, Marmara University, School of Medicine, Fevzi Cakmak Mahallesi Mimar Sinan Caddesi No: 41, 34899 Ust Kaynarca Pendik, Istanbul (Turkey); Bugdayci, Onur, E-mail: onurbug@hotmail.com [Department of Radiology, Marmara University, School of Medicine, Fevzi Cakmak Mahallesi Mimar Sinan Caddesi No: 41, 34899 Ust Kaynarca Pendik, Istanbul (Turkey); Aydin, Hilal, E-mail: hilalaltasaydin@gmail.com [Department of Radiology, Marmara University, School of Medicine, Fevzi Cakmak Mahallesi Mimar Sinan Caddesi No: 41, 34899 Ust Kaynarca Pendik, Istanbul (Turkey); Aribal, Erkin, E-mail: earibal@gmail.com [Department of Radiology, Marmara University, School of Medicine, Fevzi Cakmak Mahallesi Mimar Sinan Caddesi No: 41, 34899 Ust Kaynarca Pendik, Istanbul (Turkey)

    2014-04-15

    Purpose: The aim of this single center study is to evaluate the effectiveness of performing ultrasound-guided thyroid fine-needle aspiration biopsies (FNAB) performed by the radiologist alone without an on-site cytopathologist. Materials and methods: In this prospective randomized study, 203 patients with single nodules measuring 10 mm or more underwent ultrasound-guided FNAB: 102 patients underwent FNAB performed by the radiologist accompanied by a cytopathologist (control group); 101 patients underwent FNAB by the radiologist alone (study group). In both groups biopsy time, specimen adequacy ratio, total aspiration number, cytopathologist's cytological diagnosis time (t1), cytopathologist's total time consumption (t2) were evaluated. Results: Mean total biopsy time was 8.74 ± 2.31 min in the study group and was significantly shorter than the control group's 11.97 ± 6.75 min (p = 0.004). The average number of aspirations per patient in the study group was 4.00 ± 0; compared to the control group's 3.56 ± 1.23 this was significantly higher (p = 0.001). t1 of the study group was 307.48 ± 226.32 s; compared to 350.14 ± 247.64 s in the control group, there was no statistically significant difference (p = 0.137). t2 of the study group was 672.93 ± 270.45 s; compared to the control group (707.03 ± 258.78 s) there was no statistically significant difference (p = 0.360). Diagnostic adequacy of aspirated specimens was reassessed in the pathology laboratory. In the study group, 84 out of 101 aspirations and in the control group 89 out of 102 aspirations was determined as adequate with no statistically significant difference (p = 0.302). Conclusions: We believe that in centers where a cytopathologist is not available, ultrasound-guided thyroid FNAB can be adequately performed by an experienced radiologist who was effectively trained in smear preparation.

  12. Training courses on neutron detection systems on the ISIS research reactor: on-site and through internet training

    Energy Technology Data Exchange (ETDEWEB)

    Lescop, B.; Badeau, G.; Ivanovic, S.; Foulon, F. [National Institute for Nuclear science and Technology French Atomic Energy and Alternative Energies Commission (CEA), Saclay Research Center, 91191 Gif-sur-Yvette (France)

    2015-07-01

    Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. The facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10{sup 12} n/cm{sup 2}.s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also

  13. 75 FR 76038 - General Motors Corporation, Powertrain Flint North, Including On-Site Leased Workers From Allegis...

    Science.gov (United States)

    2010-12-07

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration General Motors Corporation, Powertrain Flint North, Including On- Site Leased Workers From Allegis Group Services, Securitas and Knight Management, Flint, MI; Amended Certification Regarding Eligibility To Apply for...

  14. 75 FR 76037 - General Motors Corporation Grand Rapids Metal Center Metal Fabricating Division Including On-Site...

    Science.gov (United States)

    2010-12-07

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration General Motors Corporation Grand Rapids Metal Center Metal Fabricating Division Including On-Site Leased Workers From Securitas, Premier, EDS and Quaker Chemical Grand Rapids, MI; Amended Certification Regarding...

  15. 76 FR 13666 - General Motors Corporation; Powertrain Flint North; Including On-Site Leased Workers From Allegis...

    Science.gov (United States)

    2011-03-14

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration General Motors Corporation; Powertrain Flint North; Including On- Site Leased Workers From Allegis Group Services, Securitas, Knight Management and URS Corporation, Flint, MI; Amended Certification Regarding Eligibilit...

  16. A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context

    Directory of Open Access Journals (Sweden)

    Stefano Gentili

    2016-01-01

    Full Text Available The reliability of DrugWipe 5A on site test for principal drugs of abuse (cannabis, amphetamines, cocaine, and opiates detection in oral fluid was assessed by comparing the on-site results with headspace solid-phase microextraction (HS-SPME gas chromatography-mass spectrometry (GC-MS analysis on samples extracted by the device collection pad. Oral fluid samples were collected at recreational settings (e.g., discos, pubs, and music bars of Rome metropolitan area. Eighty-three club goers underwent the on-site drug screening test with one device. Independently from the result obtained, a second device was used just to collect another oral fluid sample subsequently extracted and analyzed in the laboratory following HS-SPME procedure, gas chromatographic separation by a capillary column, and MS detection by electron impact ionization. DrugWipe 5A on-site test showed 54 samples (65.1% positive to one or more drugs of abuse, whereas 75 samples (90.4% tested positive for one or more substances following GC-MS assay. Comparing the obtained results, the device showed sensitivity, specificity, and accuracy around 80% for amphetamines class. Sensitivity (67 and 50% was obtained for cocaine and opiates, while both sensitivity and accuracy were unsuccessful (29 and 53%, resp. for cannabis, underlying the limitation of the device for this latter drug class.

  17. 75 FR 22629 - Kenco Logistic Services, LLC, Electrolux Webster City, Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-04-29

    ... Employment and Training Administration Kenco Logistic Services, LLC, Electrolux Webster City, Including On... of Kenco Logistic Services, LLC, Electrolux Webster City, including on-site leased workers of... certification for workers of the subject firm. The workers provided third party logistic services for...

  18. 76 FR 61749 - SpectraWatt, Inc. Including On-Site Leased Workers From Kelly Services Hopewell Junction, NY...

    Science.gov (United States)

    2011-10-05

    ... the subject firm were engaged in employment related to the production of solar cells for their application in solar panels. The worker group includes on-site leased workers from Kelly Services. During the... articles like or directly competitive with solar cells produced by the subject firm have increased,...

  19. 77 FR 3500 - Reading Powder Coatings, Inc., Including On-Site Leased Workers From Berks and Beyond Employment...

    Science.gov (United States)

    2012-01-24

    ...] Reading Powder Coatings, Inc., Including On-Site Leased Workers From Berks and Beyond Employment Services and Gage Personnel Reading, PA; Amended Certification Regarding Eligibility To Apply for Worker... Assistance and Alternative Trade Adjustment Assistance on October 19, 2011, applicable to workers of...

  20. 76 FR 66328 - Callaway Golf Ball Operations, Inc., Including On-Site Leased Workers From Reliable Temp Services...

    Science.gov (United States)

    2011-10-26

    ... From Reliable Temp Services, Inc., Johnson & Hill Staffing and Apollo Security, Chicopee, MA; Amended... from Reliable Temp Services, Inc., and Johnson and Hill Staffing, Chicopee, Massachusetts. The workers... Operations, Inc., including on-site leased workers from Reliable Temp Services, Inc., Johnson & Hill Staffing...

  1. 75 FR 3250 - The Boeing Company Commercial Aircraft Group, Including On-Site Leased Workers From Comforce...

    Science.gov (United States)

    2010-01-20

    ... Workers From Comforce Corporation, Adecco, Multax, Inconen, CTS, Hi-Tec, Woods, Ciber, Kelly Services... On-Site Leased Workers From Comforce Corporation, Adecco, Multax, Inconen, CTS, Hi-Tec, Woods, Ciber..., Adecco, Multax, Inconen, CTS, Hi-Tec, Woods, Ciber, Kelly Services, Analysts International Corp,...

  2. 75 FR 16514 - Bayer Material Science, LLC, Formally Known as Sheffield Plastics, Including On-Site Leased...

    Science.gov (United States)

    2010-04-01

    ... Employment and Training Administration Bayer Material Science, LLC, Formally Known as Sheffield Plastics... Material Science, LLC, formally known as Sheffield Plastics, including on-site leased workers from... that Bayer Material Science, LLC was formally known as Sheffield Plastics. Some workers separated...

  3. Training Teachers On-Site: The Spring Semester 1974 at Sanostee and Toadlena. Navajo Reading Study Progress Report No. 25.

    Science.gov (United States)

    New Mexico Univ., Albuquerque. Navajo Reading Study.

    During the 1974 spring semester, the Sanostee-Toadlena Title VII Bilingual Education Project focused on "how and what to teach Navajo children". The on-site program included courses in human and growth development, classroom learning, production of materials, social studies, science methods, mathematics methods, developmental reading,…

  4. 75 FR 5637 - Bureau of Educational and Cultural Affairs; Secondary School Student Sponsor On-Site Reviews

    Science.gov (United States)

    2010-02-03

    ... of Educational and Cultural Affairs; Secondary School Student Sponsor On-Site Reviews ACTION: Notice... about America through these Secondary School Student programs. Educational and cultural exchanges are the cornerstone of U.S. public diplomacy and an integral component of American foreign policy...

  5. 75 FR 43562 - FANUC Robotics America, Inc., Including On-Site Leased Workers From Right Angle Staffing, Inc...

    Science.gov (United States)

    2010-07-26

    ... Employment and Training Administration FANUC Robotics America, Inc., Including On-Site Leased Workers From... period, Fanuc Robotics America neither imported articles like or directly competitive with the robotic... Robotics America, Inc., Rochester Hills, Michigan. Signed in Washington, DC, this 13th day of July...

  6. 75 FR 38125 - Fanuc Robotics America, Inc. Including On-Site Leased Workers From Right Angle Staffing, Inc...

    Science.gov (United States)

    2010-07-01

    ... Employment and Training Administration Fanuc Robotics America, Inc. Including On-Site Leased Workers From... based on the finding that, during the relevant period, Fanuc Robotics America neither imported articles... production of robotic systems to a foreign country. Furthermore, the Department surveyed Fanuc...

  7. 75 FR 26794 - International Paper Company Franklin Pulp & Paper Mill Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-05-12

    ...] International Paper Company Franklin Pulp & Paper Mill Including On-Site Leased Workers From Railserve, Franklin..., 2009, applicable to workers of International Paper Company, Franklin Pulp & Paper Mill, Franklin... workers are engaged in the production of uncoated freesheet paper and coated paperboard. The company...

  8. 78 FR 66780 - Salter Labs, a Subsidiary of Roundtable Healthcare Partners Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-11-06

    ... Employment and Training Administration Salter Labs, a Subsidiary of Roundtable Healthcare Partners Including..., applicable to workers of Salter Labs, a subsidiary of RoundTable Healthcare Partners, including on-site... of Salter Labs, a subsidiary of RoundTable Healthcare Partners. The Department has determined...

  9. 75 FR 20390 - Robert Bosch LLC, Including On-Site Leased Workers From Bosch Management Services North America...

    Science.gov (United States)

    2010-04-19

    ... Management Services North America, South Haven Community Hospital, Huffmaster Inc., and Williamson Employment... Management Services North America, South Haven Community Hospital, Huffmaster Inc., and Williamson Employment..., including on-site leased workers of Bosch Management Services North America, South Haven Community...

  10. 76 FR 50272 - West, A Thomson Reuters Business, Thomson Reuters Legal Division, Including On-Site Leased...

    Science.gov (United States)

    2011-08-12

    ... Employment and Training Administration West, A Thomson Reuters Business, Thomson Reuters Legal Division... Reuters Business, Thomson Reuters Legal Division, including On-Site Leased Workers from Adecco... applicable to workers and former workers of West, A Thomson Reuters Business, Thomson Reuters...

  11. 77 FR 44685 - ConocoPhillips Company, Trainer Refinery, Including On-Site Leased Workers From Shrack, Young...

    Science.gov (United States)

    2012-07-30

    ... Employment and Training Administration ConocoPhillips Company, Trainer Refinery, Including On-Site Leased Workers From Shrack, Young, and Associates, Inc., and Project Control Associates, Trainer, PA; Notice of... of ConocoPhillips Company, Trainer Refinery, Trainer, Pennsylvania (subject firm). The subject...

  12. 75 FR 57505 - Dell Products LP, Winston-Salem (WS-1) Division, Including On-Site Leased Workers From Adecco...

    Science.gov (United States)

    2010-09-21

    ... of desktop computers. New information shows that workers leased from Omni Resources and Recovery were...) Division. The Department has determined that on-site workers from Omni Resources and Recovery were... Leased Workers From Adecco, Spherion, Patriot Staffing, Manpower, Teksystems, APN, ICONMA,...

  13. 75 FR 56564 - Dell Products LP, Winston-Salem (WS-1) Division Including On-Site Leased Workers From Adecco...

    Science.gov (United States)

    2010-09-16

    ... of desktop computers. New information shows that workers leased from Omni Resources and Recovery were...) Division. The Department has determined that on-site workers from Omni Resources and Recovery were... Leased Workers From Adecco, Spherion, Patriot Staffing, Manpower, Teksystems, APN, Iconma,...

  14. 75 FR 55614 - Dell Products LP, Winston-Salem (WS-1) Division, Including On-Site Leased Workers From Adecco...

    Science.gov (United States)

    2010-09-13

    ... of desktop computers. New information shows that workers leased from Omni Resources and Recovery were...) Division. The Department has determined that on-site workers from Omni Resources and Recovery were... Leased Workers From Adecco, Spherion, Patriot Staffing, Manpower, Teksystems, APN, Iconma,...

  15. 77 FR 70478 - RG Steel Wheeling, LLC, Wheeling Office, A Division Of RG Steel, LLC, Including On-Site Leased...

    Science.gov (United States)

    2012-11-26

    ..., Including On-Site Leased Workers From Pro Unlimited and Green Energy Initiatives LLC, Including Workers...-site leased workers from Pro Unlimited and Green Energy Initiatives, LLC, Wheeling, West Virginia (TA-W... their wages reported through a separate unemployment insurance (UI) tax account under the name...

  16. On-site observations of physical work demands of train conductors and service electricians in the Netherlands.

    NARCIS (Netherlands)

    Botje, D.; Zoer, I.; Ruitenburg, M.M.; Frings-Dresen, H.W.; Sluiter, J.K.

    2010-01-01

    The objective of the present study was to assess the exposure to physical work demands of train conductors and service electricians at a railway company in the Netherlands. On-site observations were performed using the Task Recording and Analysis on Computer observation system to identify the mean

  17. 75 FR 9442 - AK Steel Corporation, Mansfield Works Division, Including On-Site Leased Workers From Time...

    Science.gov (United States)

    2010-03-02

    ... Employment and Training Administration TA-W-71,375 AK Steel Corporation, Mansfield Works Division, Including... impacted employment at AK Steel Corporation, Mansfield Works Division, Mansfield, Ohio. The survey of the... Corporation, Mansfield Works Division, including on-site leased workers from Time Customized...

  18. 77 FR 17525 - Cinram Distribution, LLC, a Subsidiary of Cinram International Income Fund, Including On-Site...

    Science.gov (United States)

    2012-03-26

    ... Employment and Training Administration Cinram Distribution, LLC, a Subsidiary of Cinram International Income... Distribution, LLC, a subsidiary of Cinram International Income Fund, including on-site leased workers from Good... Distribution, LLC, a subsidiary of Cinram International Income Fund had their wages reported through a...

  19. 75 FR 34172 - Rexam Closure Systems, Inc., a Subsidiary of Rexam PLC, Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-06-16

    ... Unemployment Insurance (UI) Wages Are Paid Through Owens Illinois Manufacturing, Hamlet, NC; Amended... workers of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC, Hamlet, North Carolina. The notice was... from Olston Staffing were employed on-site at the Hamlet, North Carolina location of Rexam Closure...

  20. An analytical evaluation of eight on-site oral fluid drug screening devices using laboratory confirmation results from oral fluid.

    NARCIS (Netherlands)

    Blencowe, T. Pehrsson, A. Lillsunde, P. Vimpari, K. Houwing, S. Smink, B. Mathijssen, R. Linden, T. van der Legrand, S.A. Pil, K. & Verstraete, A.

    2011-01-01

    The performance of eight on-site oral fluid drug screening devices was studied in Belgium, Finland and the Netherlands as a part of the EU-project DRUID. The main objective of the study was to evaluate the reliability of the devices for testing drivers suspected of driving under the influence of dru

  1. 77 FR 56870 - New Process Gear, a Division of Magna Powertrain, Including On-Site Leased Workers From ABM...

    Science.gov (United States)

    2012-09-14

    ... Employment and Training Administration New Process Gear, a Division of Magna Powertrain, Including On- Site... of New Process Gear, a division of Magna Powertrain, East Syracuse, New York, The workers produce... Syracuse, New York location of New Process Gear, a division of Magna Powertrain. The Department...

  2. Applying the 5 WHYs to Identify Root Causes to Non-completions in On-Site Construction

    DEFF Research Database (Denmark)

    Lindhard, Søren Munch

    2014-01-01

    In on-site production, mass-customized subproducts are assembled through standardized processes. The production is pushing mass customization to the edge by producing unique and complex products. Due to the project structure, it has proven difficult to avoid repetitions of problems and to learn f...

  3. 76 FR 16446 - Delphi Corporation Electronics And Safety Division Including On-Site Leased Workers From Acro...

    Science.gov (United States)

    2011-03-23

    ... Employment and Training Administration Delphi Corporation Electronics And Safety Division Including On- Site... Alternative Trade Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974 (19 U.S.C. 2273), and Section 246 of the Trade Act of 1974 (26 U.S.C. 2813), as amended, the Department of...

  4. 75 FR 20391 - Agrium U.S., Inc., Kenai Nitrogen Operation, Including On-Site Leased Workers From NMS (Nana...

    Science.gov (United States)

    2010-04-19

    ... Workers From NMS (Nana Management Systems) and Heat & Frost Insulation, Inc., Kenai, AK; Amended Notice of... October 22, 2008 to include on- site leased workers from NMS (Nana Management Systems). The notice was... leased workers from NMS (Nana Management Systems) and Heat & Frost Insulation, Inc., Kenai, Alaska,...

  5. 78 FR 15049 - The Evercare Company Including On-Site Leased Workers From Global Personnel Solutions and...

    Science.gov (United States)

    2013-03-08

    ... Personnel Solutions and Manpower Waynesboro, Georgia; Amended Certification Regarding Eligibility To Apply... workers from Global Personnel Solutions. In response to an inquiry by the State of Georgia, the Department... Company, including on-site leased workers from Global Personnel Solutions and Manpower,...

  6. 75 FR 65515 - NRC Corporation, USPS Help Desk of Customer Care Center, Including On-Site Leased Workers of Volt...

    Science.gov (United States)

    2010-10-25

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration NRC Corporation, USPS Help Desk of Customer Care Center, Including On-Site Leased Workers of Volt Consulting, West Columbia, SC; Notice of Affirmative...

  7. 75 FR 21353 - Intel Corporation, Fab 20 Division, Including On-Site Leased Workers From Volt Technical...

    Science.gov (United States)

    2010-04-23

    ... Employment and Training Administration Intel Corporation, Fab 20 Division, Including On-Site Leased Workers... for Worker Adjustment Assistance on March 10, 2010, applicable to workers of Intel Corporation, Fab 20... the Hillsboro, Oregon location of Intel Corporation, Fab 20 Division. The Department has...

  8. 77 FR 29362 - Kohler Company, Malvern Division, Including On-Site Leased Workers From Manpower Staffing and Dow...

    Science.gov (United States)

    2012-05-17

    ... From Manpower Staffing and Dow Cleaning Services, Malvern, AR; Amended Certification Regarding... reports that workers from Dow Cleaning Services were employed on-site at the Malvern, Arkansas location of... Department is amending this certification to include workers leased from Dow Cleaning Services working...

  9. 75 FR 20382 - Chrysler LLC, St. Louis North Assembly Plant, Including On-Site Leased Workers From HAAS TCM, Inc...

    Science.gov (United States)

    2010-04-19

    ... Logistics Management Services, Inc., Fenton, MO; Amended Certification Regarding Eligibility To Apply for... Adjustment Assistance petition (TA-W-72,679) that workers of Logistics Management Services, Inc. worked on-site at the Chrysler LLC, Fenton, Missouri plant (Logistics Management Services, Inc....

  10. 75 FR 20384 - Chrysler LLC, St. Louis North Assembly Plant, Including On-Site Leased Workers From Haas TCM, Inc...

    Science.gov (United States)

    2010-04-19

    ... Logistics Management Services, Inc. Fenton, MO; Amended Certification Regarding Eligibility To Apply for... Adjustment Assistance petition (TA-W-72,679) that workers of Logistics Management Services, Inc. worked on-site at the Chrysler LLC, Fenton, Missouri plant (Logistics Management Services, Inc....

  11. Coupling shell-isolated nanoparticle enhanced Raman spectroscopy with paper chromatography for multi-components on-site analysis.

    Science.gov (United States)

    Zhang, Kun; Qing, Jiang; Gao, Han; Ji, Ji; Liu, Baohong

    2017-01-01

    By coupling shell-isolated nanoparticle-enhanced Raman spectroscopy (SHINERS) with paper chromatography, two birds with one stone method were developed for simultaneous on-site separation and optical detection of multiple components. The established method features high sensitivity of plasmon-enhanced sensing strategies and sufficient temporal and spatial resolution of planar chromatographic techniques.

  12. 75 FR 49525 - World Color (USA), LLC Formerly Known as Quebecor World World Color Covington Including On-Site...

    Science.gov (United States)

    2010-08-13

    ... Employment and Training Administration World Color (USA), LLC Formerly Known as Quebecor World World Color... to workers of World Color (USA), LLC, formerly known as Quebecor World, World Color Covington... IH Services were employed on-site at the Covington, Tennessee, location of World Color (USA),...

  13. Simple on-site assembled blower-mister device provides sufficient humidification and visualization in off-pump surgery.

    Science.gov (United States)

    Wippermann, Jens; Albes, Johannes M; Liebing, Kai; Breuer, Martin; Kaluza, Mirko; Strauch, Justus; Wahlers, Thorsten

    2006-09-01

    To effectively perform an anastomosis on a coronary artery under beating heart conditions, the anastomotic site must be cleared of blood to allow visualization for accurate suturing. We describe a simple, cost effective, on-site assembled blower-mister system.

  14. Does on-site chaplaincy enhance the health and well being of fly-in, fly-out (FIFO) personnel?

    Science.gov (United States)

    Ebert, Angela; Strehlow, Karin

    2016-10-06

    Issue addressed: The fly-in, fly-out (FIFO) work style has been linked to mental-health and interpersonal issues and a need for strategies that maintain a healthy workforce. This study investigated whether 24/7 on-site chaplains deliver a service that promotes the health and well being of FIFO personnel.Methods: A phenomenological approach was used to explore the perceptions of FIFO personnel working in different roles and organisational sections on a remote mine site in Western Australia. Multi-pronged strategies recruited 29 participants who represented management, supervisors, workers and support staff. Participants took part in semistructured interviews conducted either one-on-one or in pairs.Results: Chaplains were described as making a valuable contribution to the physical and mental health of FIFO personnel. Specific aspects of the service such as active outreach, effective trust building and the on-site availability were identified as central to the service being accessed and overcoming barriers embedded in mining culture and masculinity.Conclusions: On-site chaplaincy appears to be effective in promoting the physical and mental health of FIFO personnel working at a remote mine site.So what?: This promising model of active on-site outreach offered by chaplains is set apart from existing FIFO support structures. We recommend further exploration of its potential to become part of an integrated health-support system in the mining sector and other industries.

  15. 75 FR 45160 - SKF Aeroengine Falconer a Subsidiary of AB SKF Including On-Site Leased Workers From Manpower...

    Science.gov (United States)

    2010-08-02

    ..., Falconer, New York. The notice was published in the Federal Register on March 12, 2010 (75 FR 11924). At... Employment and Training Administration SKF Aeroengine Falconer a Subsidiary of AB SKF Including On-Site... February 4, 2010, applicable to workers of SKF Aeroengine Falconer, a subsidiary of AB SKF, including...

  16. 76 FR 46852 - Workers From Kelly Services, Working On-Site at Delphi Automotive Systems, LLC, Powertrain...

    Science.gov (United States)

    2011-08-03

    ... workers from Kelly Services working on-site at Delphi Automotive Systems, LLC, El Paso, Texas. The workers...-site at Delphi Automotive Systems, LLC, Powertrain Division, El Paso, Texas. The amended notice...-site at Delphi Automotive Systems, LLC, Powertrain Division, El Paso, Texas, who became totally...

  17. 28 CFR Appendix C to Part 79 - Radiation Exposure Compensation Act Offset Worksheet-On Site Participants

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Radiation Exposure Compensation Act Offset Worksheet-On Site Participants C Appendix C to Part 79 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) CLAIMS UNDER THE RADIATION EXPOSURE COMPENSATION ACT Pt. 79, App. C Appendix C to...

  18. 76 FR 62452 - Avon Products, Inc. Including On-Site Leased Workers From Spherion/Source Right, Springdale, OH...

    Science.gov (United States)

    2011-10-07

    .../Source Right, Springdale, OH; Amended Certification Regarding Eligibility To Apply for Worker Adjustment... that workers leased from Spherion/Source Right were employed on-site at the Springdale, Ohio location... Department is amending this certification to include workers leased from Spherion/Source Right working on...

  19. 76 FR 62451 - Avon Products, Inc., Including On-Site Leased Workers From Spherion/Source Right, Springdale...

    Science.gov (United States)

    2011-10-07

    .../Source Right, Springdale, Ohio; Amended Certification Regarding Eligibility To Apply for Worker... company reports that workers leased from Spherion/Source Right were employed on-site at the Springdale... leased workers from Spherion/Source Right, Springdale, Ohio, who became totally or partially separated...

  20. 78 FR 31593 - Aleris Recycling Bens Run, LLC, Including On-Site Leased Workers From Winans Extras Support...

    Science.gov (United States)

    2013-05-24

    ... Bens Run, LLC, Including On-Site Leased Workers From Winans Extras Support Staffing and CDI Corporation... (TAA) applicable to workers and former workers of Aleris Recycling Bens Run, LLC, Friendly, West... resulting in an affirmative finding of serious injury, market disruption, or material injury, or...

  1. 77 FR 75448 - Welded Tube-Berkeley Including On-Site Leased Workers From Snelling, Aerotek and Express...

    Science.gov (United States)

    2012-12-20

    ... Employment and Training Administration Welded Tube--Berkeley Including On-Site Leased Workers From Snelling... Worker Adjustment Assistance on October 10, 2012, applicable to workers of Welded Tube--Berkeley... Welded Tube-- Berkeley. The Department has determined that these workers were sufficiently under...

  2. 76 FR 21033 - Core Industries, Inc., DBA Star Trac, Including On-Site Leased Workers From Aerotek, Helpmates...

    Science.gov (United States)

    2011-04-14

    ... Employment and Training Administration Core Industries, Inc., DBA Star Trac, Including On-Site Leased Workers From Aerotek, Helpmates, Mattson, and Empire Staffing, Irvine, CA and Core Industries, Inc., DBA Star..., 2011, applicable to workers of Core Industries, Inc., DBA Star Trac, Irvine, California. The notice...

  3. 75 FR 879 - Sanford, Including On-Site Leased Workers From Holland Employment and Willstaff, Lewisburg, TN...

    Science.gov (United States)

    2010-01-06

    ... Employment and Training Administration Sanford, Including On-Site Leased Workers From Holland Employment and...-site leased workers from Holland Employment, Lewisburg, Tennessee. The notice was published in the... leased workers from Holland Employment and Willstaff, Lewisburg, Tennessee, who became totally...

  4. 75 FR 41531 - Hewlett Packard (HP) Global Product Development, Working On-Site at General Motors Corporation...

    Science.gov (United States)

    2010-07-16

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration Hewlett Packard (HP) Global Product Development, Working On-Site at General Motors Corporation, Milford, MI; Notice of Revised Termination of Investigation Pursuant to...

  5. 76 FR 13665 - Cambridge Tool & Die, Including On-Site Leased Workers From Action Total Staffing, Cambridge, OH...

    Science.gov (United States)

    2011-03-14

    ... Register on January 26, 2011 (76 FR 4731). At the request of the State agency, the Department reviewed the... Employment and Training Administration Cambridge Tool & Die, Including On-Site Leased Workers From Action Total Staffing, Cambridge, OH; Amended Certification Regarding Eligibility To Apply for...

  6. 76 FR 61740 - Geneon Entertainment (USA) Including On-Site Leased Workers From Interplace, Inc., Apple One and...

    Science.gov (United States)

    2011-10-05

    ... Interplace, Inc., Apple One and Robert Half Legal Santa Monica, CA; Amended Certification Regarding..., applicable to workers of Geneon Entertainment (USA), including on-site leased workers from Interplace, Inc., and Apple One, Santa Monica, California. The workers are engaged in activities related to...

  7. 75 FR 41523 - Paris Accessories, Inc., Including On-Site Leased Workers From Job Connections, New Smithville...

    Science.gov (United States)

    2010-07-16

    ... on May 27, 2010. The Notice was published in the Federal Register on June 16, 2010 (75 FR 34180). The... Employment and Training Administration Paris Accessories, Inc., Including On-Site Leased Workers From Job Connections, New Smithville, PA; Paris Accessories, Inc., Allentown, PA; Amended Certification...

  8. Power curve measurement with Spinner Anemometer according to IEC 61400-12-2

    DEFF Research Database (Denmark)

    Demurtas, Giorgio

    In wind industry power performance measurements on site is an increasing challenge due to the larger and larger rotors. An IEC standard on power performance verification with nacelle anemometry, IEC61400-12-2 [1], has been developed and was published 2013. However, nacelle anemometry has a number...

  9. Power optics

    Energy Technology Data Exchange (ETDEWEB)

    Apollonov, V V [A M Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2014-02-28

    By using the theory we developed in the early 1970s, a broad range of phenomena is considered for an optical surface of a solid body that is exposed to radiation arbitrarily varying in time and producing temperature fields, thermoelastic stresses and thermal deformations on the surface layer. The examination is based on the relations (which are similar to Duhamel's integral formula from the theory of heat conduction) between the quantities characterising the thermal stress state in any nonstationary regimes of energy input into a solid. A peculiar feature of the analysis of the thermal stress state in this case consists in the fact that this relation comprises time as a parameter, which in turn is a consequence of incoherence of the quasi-stationary problem of thermoelasticity. This phenomenon is particularly important for the optics of high-power, high-pulse repetition rate lasers, which are being actively developed. In the review, we have recently published in Laser Physics, the thermal stress state of a solid is analysed. In this state, time is treated as an independent variable used in differentiation. Such an approach greatly reduces the applicability of the method. The review published contains data on the use of capillary porous structures made of various materials with different degrees of the surface development. Moreover, such structures can be efficiently employed to increase the heat exchange at a temperature below the boiling point of the coolant. In the present review we discuss the dependences of the limiting laser intensities on the duration of a pulse or a pulse train, corresponding to the three stages of the state of the reflecting surface and leading to unacceptable elastic deformations of the surface, to the plastic yield of the material accompanied by the formation of residual stresses and to the melting of the surface layer. We also analyse the problem of heat exchange in the surface layer with a liquid metal coolant pumped through it

  10. Power optics

    Science.gov (United States)

    Apollonov, V. V.

    2014-02-01

    By using the theory we developed in the early 1970s, a broad range of phenomena is considered for an optical surface of a solid body that is exposed to radiation arbitrarily varying in time and producing temperature fields, thermoelastic stresses and thermal deformations on the surface layer. The examination is based on the relations (which are similar to Duhamel's integral formula from the theory of heat conduction) between the quantities characterising the thermal stress state in any nonstationary regimes of energy input into a solid. A peculiar feature of the analysis of the thermal stress state in this case consists in the fact that this relation comprises time as a parameter, which in turn is a consequence of incoherence of the quasi-stationary problem of thermoelasticity. This phenomenon is particularly important for the optics of high-power, high-pulse repetition rate lasers, which are being actively developed. In the review, we have recently published in Laser Physics, the thermal stress state of a solid is analysed. In this state, time is treated as an independent variable used in differentiation. Such an approach greatly reduces the applicability of the method. The review published contains data on the use of capillary porous structures made of various materials with different degrees of the surface development. Moreover, such structures can be efficiently employed to increase the heat exchange at a temperature below the boiling point of the coolant. In the present review we discuss the dependences of the limiting laser intensities on the duration of a pulse or a pulse train, corresponding to the three stages of the state of the reflecting surface and leading to unacceptable elastic deformations of the surface, to the plastic yield of the material accompanied by the formation of residual stresses and to the melting of the surface layer. We also analyse the problem of heat exchange in the surface layer with a liquid metal coolant pumped through it. The

  11. Mapping and Imaging Methodologies within the Comprehensive Test Ban Treaty's On-Site Inspection Framework

    Science.gov (United States)

    Hawkins, W.; Sussman, A. J.; Kelley, R. E.; Wohletz, K. H.; Schultz-Fellenz, E. S.

    2013-12-01

    On-site inspection (OSI) is the final verification measure of the Comprehensive Nuclear Test Ban Treaty (CTBT). OSIs rely heavily on geologic and geophysical investigations. The objective is to apply methods that are effective, efficient and minimally intrusive. We present a general overview of the OSI as provisioned in the CTBT, specifying the allowed techniques and the timeline for their application. A CTBT OSI relies on many geological, geophysical and radiological methods. The search area for an OSI is mostly defined by uncertainty in the location of a suspect event detected by the International Monitoring System (IMS) and reported through the International Data Center and can be as large as 1000 km2. Thus OSI methods are fundamentally divided into general survey methods that narrow the search area and more focused, detailed survey methods to look for evidence of a potential underground explosion and try to find its location within an area of several km2. The purpose and goal of a CTBT OSI, as specified in the Article IV of the Treaty, is 'to clarify whether a nuclear explosion has been carried out in violation of the Treaty' and to 'gather any facts which might assist in identifying any possible violator.' Through the use of visual, geophysical, and radiological techniques, OSIs can detect and characterize anomalies and artifacts related to the event that triggered the inspection. In the context of an OSI, an 'observable' is a physical property that is important to recognize and document because of its relevance to the purpose of the inspection. Potential observables include: (1) visual observables such as ground/environmental disturbances and manmade features, (2) geophysical techniques that provide measurements of altered and damaged ground and buried artifacts, and (3) radiological measurements on samples. Information provided in this presentation comes from observations associated with historical testing activities that were not intended to go undetected

  12. Primer on Use of Multi-Spectral and Infra Red Imaging for On-Site Inspections

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, J R

    2010-10-26

    The purpose of an On-Site Inspection (OSI) is to determine whether a nuclear explosion has occurred in violation of the Comprehensive Nuclear Test Ban Treaty (CTBT), and to gather information which might assist in identifying the violator (CTBT, Article IV, Paragraph 35) Multi-Spectral and Infra Red Imaging (MSIR) is allowed by the treaty to detect observables which might help reduce the search area and thus expedite an OSI and make it more effective. MSIR is permitted from airborne measurements, and at and below the surface to search for anomalies and artifacts (CTBT, Protocol, Part II, Paragraph 69b). The three broad types of anomalies and artifacts MSIR is expected to be capable of observing are surface disturbances (disturbed earth, plant stress or anomalous surface materials), human artifacts (man-made roads, buildings and features), and thermal anomalies. The purpose of this Primer is to provide technical information on MSIR relevant to its use for OSI. It is expected that this information may be used for general background information, to inform decisions about the selection and testing of MSIR equipment, to develop operational guidance for MSIR use during an OSI, and to support the development of a training program for OSI Inspectors. References are provided so readers can pursue a topic in more detail than the summary information provided here. The following chapters will provide more information on how MSIR can support an OSI (Section 2), a short summary what Multi-Spectral Imaging and Infra Red Imaging is (Section 3), guidance from the CTBT regarding the use of MSIR (Section 4), and a description of several nuclear explosion scenarios (Section 5) and consequent observables (Section 6). The remaining sections focus on practical aspects of using MSIR for an OSI, such as specification and selection of MSIR equipment, operational considerations for deployment of MISR equipment from an aircraft, and the conduct of field exercises to mature MSIR for an OSI

  13. Influence of Palythoa caribaeorum (Anthozoa, Cnidaria zonation on site-attached reef fishes

    Directory of Open Access Journals (Sweden)

    José P. Mendonça-Neto

    2008-09-01

    Full Text Available This work aimed to test the influence of Palythoa caribeorum, a widely distributed zoanthid in the Atlantic, on site-attached reef fish in a subtropical rocky shore. Density, richness and vertical distribution of reef fish inside (ID and outside (OD previously chosen P. caribaeorum dominance patches were compared through stationary visual censuses along three different periods. Fishes were grouped in different trophic guilds to evidence differences in resources uses in both treatments. A complexity index was estimated by the chain link method and percentage covering of benthic organisms was obtained analyzing random points from replicated photo-quadrats. We observed thirty-eight species of fishes, belonging to twenty-five families. Reef fish communities between studied patches were similar,both in terms of species composition and vertical distribution. Considering only the most site-attached fishes, which were the most frequent and abundant species, data showed that ID sustains higher diversity and abundance than OD. Results showed that benthic composition differ significantly among patches whereas complexity remained without differences. Otherwise, results indicated that these areas might play an important role in space limitation, structuring neighboring benthic community and consequently reef fish assemblages.Este estudo visou testar a influência de Palythoa caribeorum, um zoantídeo amplamente distribuído no Atlântico, na estruturação da comunidade de peixes recifais associados a um costão rochoso de uma região subtropical. A densidade, a riqueza e a distribuição vertical de peixes recifais em áreas previamente selecionadas com e sem a dominância de Palythoa caribaeorum foram comparadas através de censos visuais estacionários em três períodos distintos de tempo. Os peixes foram agrupados em guildas tróficas a fim de evidenciar diferenças nos usos dos recursos nas diferentes áreas analisadas. Foram analisados também

  14. Fatigue analyses of the prototype Francis runners based on site measurements and simulations

    Science.gov (United States)

    Huang, X.; Chamberland-Lauzon, J.; Oram, C.; Klopfer, A.; Ruchonnet, N.

    2014-03-01

    With the increasing development of solar power and wind power which give an unstable output to the electrical grid, hydropower is required to give a rapid and flexible compensation, and the hydraulic turbines have to operate at off-design conditions frequently. Prototype Francis runners suffer from strong vibrations induced by high pressure pulsations at part load, low part load, speed-no-load and during start-stops and load rejections. Fatigue and damage may be caused by the alternating stress on the runner blades. Therefore, it becomes increasingly important to carry out fatigue analysis and life time assessment of the prototype Francis runners, especially at off-design conditions. This paper presents the fatigue analyses of the prototype Francis runners based on the strain gauge site measurements and numerical simulations. In the case of low part load, speed-no-load and transient events, since the Francis runners are subjected to complex hydraulic loading, which shows a stochastic characteristic, the rainflow counting method is used to obtain the number of cycles for various dynamic amplitude ranges. From middle load to full load, pressure pulsations caused by Rotor-stator- Interaction become the dominant hydraulic excitation of the runners. Forced response analysis is performed to calculate the maximum dynamic stress. The agreement between numerical and experimental stresses is evaluated using linear regression method. Taking into account the effect of the static stress on the S-N curve, the Miner's rule, a linear cumulative fatigue damage theory, is employed to calculate the damage factors of the prototype Francis runners at various operating conditions. The relative damage factors of the runners at different operating points are compared and discussed in detail.

  15. Evaluation of Approaches for Managing Nitrate Loading from On-Site Wastewater Systems near La Pine, Oregon

    Science.gov (United States)

    Morgan, David S.; Hinkle, Stephen R.; Weick, Rodney J.

    2007-01-01

    This report presents the results of a study by the U.S. Geological Survey, done in cooperation with the Oregon Department of Environmental Quality and Deschutes County, to develop a better understanding of the effects of nitrogen from on-site wastewater disposal systems on the quality of ground water near La Pine in southern Deschutes County and northern Klamath County, Oregon. Simulation models were used to test the conceptual understanding of the system and were coupled with optimization methods to develop the Nitrate Loading Management Model, a decision-support tool that can be used to efficiently evaluate alternative approaches for managing nitrate loading from on-site wastewater systems. The conceptual model of the system is based on geologic, hydrologic, and geochemical data collected for this study, as well as previous hydrogeologic and water quality studies and field testing of on-site wastewater systems in the area by other agencies. On-site wastewater systems are the only significant source of anthropogenic nitrogen to shallow ground water in the study area. Between 1960 and 2005 estimated nitrate loading from on-site wastewater systems increased from 3,900 to 91,000 pounds of nitrogen per year. When all remaining lots are developed (in 2019 at current building rates), nitrate loading is projected to reach nearly 150,000 pounds of nitrogen per year. Low recharge rates (2-3 inches per year) and ground-water flow velocities generally have limited the extent of nitrate occurrence to discrete plumes within 20-30 feet of the water table; however, hydraulic-gradient and age data indicate that, given sufficient time and additional loading, nitrate will migrate to depths where many domestic wells currently obtain water. In 2000, nitrate concentrations greater than 4 milligrams nitrogen per liter (mg N/L) were detected in 10 percent of domestic wells sampled by Oregon Department of Environmental Quality. Numerical simulation models were constructed at transect (2

  16. Wind Power - A Power Source Enabled by Power Electronics

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Chen, Zhe

    2004-01-01

    . The deregulation of energy has lowered the investment in bigger power plants, which means the need for new electrical power sources may be very high in the near future. Two major technologies will play important roles to solve the future problems. One is to change the electrical power production sources from...... electronics is changing from being a minor energy source to be acting as an important power source. By that wind power is also getting an added value....

  17. Power management system

    Science.gov (United States)

    Algrain, Marcelo C.; Johnson, Kris W.; Akasam, Sivaprasad; Hoff, Brian D.

    2007-10-02

    A method of managing power resources for an electrical system of a vehicle may include identifying enabled power sources from among a plurality of power sources in electrical communication with the electrical system and calculating a threshold power value for the enabled power sources. A total power load placed on the electrical system by one or more power consumers may be measured. If the total power load exceeds the threshold power value, then a determination may be made as to whether one or more additional power sources is available from among the plurality of power sources. At least one of the one or more additional power sources may be enabled, if available.

  18. On-site gamma-ray spectroscopic measurements of fission gas release in irradiated nuclear fuel.

    Science.gov (United States)

    Matsson, I; Grapengiesser, B; Andersson, B

    2007-01-01

    An experimental, non-destructive in-pool, method for measuring fission gas release (FGR) in irradiated nuclear fuel has been developed. Using the method, a significant number of experiments have been performed in-pool at several nuclear power plants of the BWR type. The method utilises the 514 keV gamma-radiation from the gaseous fission product (85)Kr captured in the fuel rod plenum volume. A submergible measuring device (LOKET) consisting of an HPGe-detector and a collimator system was utilised allowing for single rod measurements on virtually all types of BWR fuel. A FGR database covering a wide range of burn-ups (up to average rod burn-up well above 60 MWd/kgU), irradiation history, fuel rod position in cross section and fuel designs has been compiled and used for computer code benchmarking, fuel performance analysis and feedback to reactor operators. Measurements clearly indicate the low FGR in more modern fuel designs in comparison to older fuel types.

  19. Bioremediation demonstration on Kwajalein Island: Site characterization and on-site biotreatability studies

    Energy Technology Data Exchange (ETDEWEB)

    Siegrist, R.L.; Korte, N.E.; Pickering, D.A. (Oak Ridge National Lab., TN (United States)); Phelps, T.J. (Tennessee Univ., Knoxville, TN (United States))

    1991-09-01

    An environmental study was conducted during February 1991 on Kwajalein Island, a US Army Kwajalein Atoll (USAKA) Base in the Republic of the Marshall Islands (RMI). This study was undertaken for the US Department of Energy (DOE) Hazardous Waste Remedial Actions Program (HAZWRAP) acting in behalf of USAKA. The purpose of the study was to determine if selected locations for new construction on Kwajalein Island were contaminated by petroleum hydrocarbons as suspected and, if so, whether bioremediation appeared to be a feasible technology for environmental restoration. Two different sites were evaluated: (1) the site planned freshwater production facility and (2) a site adjacent to an aboveground diesel fuel storage tank. Within the proposed construction zone for the freshwater production facility (a.k.a desalination plant), total petroleum hydrocarbons (TPH) where either absent or at low levels. Characterization data for another potential construction site adjacent to an aboveground diesel fuel storage tank southeast of the old diesel power plant revealed high concentrations of diesel fuel in the soil and groundwater beneath the site. Results of this investigation indicate that there are petroleum-contaminated soils on Kwajalein Island and bioremediation appears to be a viable environmental restoration technique. Further experimentation and field demonstration are required to determine the design and operating conditions that provide for optimum biodegradation and restoration of the petroleum-contaminated soils. 17 refs., 7 figs., 26 figs.

  20. Use of on-site high performance liquid chromatography to evaluate the magnitude and extent of organic contaminants in aquifers

    Science.gov (United States)

    Goerlitz, D.F.; Franks, B.J.

    1989-01-01

    Appraisal of ground water contaminated by organic substances raises problems of difficult sample collection and timely chemical analysis. High-performance liquid chromatography was evaluated for on-site determination of specific organic contaminants in ground water samples and was used at three study sites. Organic solutes were determined directly in water samples, with little or no preparation, and usually in less than an hour after collection. This information improved sampling efficiency and was useful in screening for subsequent laboratory analysis. On two occasions, on-site analysis revealed that samples were undergoing rapid change, with major solutes being upgraded and alteration products being formed. In addition to sample stability, this technique proved valuable for monitoring other sampling factors such as compositional changes with respect to pumping, filtration, and cross contamination. -Authors

  1. On-site solid-phase extraction and application to in situ preconcentration of heavy metals in surface water.

    Science.gov (United States)

    Jiao, Fang; Gao, Hong-Wen

    2013-01-01

    An on-site solid-phase extraction, consisting of the sorption, the separation and the elution function units, was designed for in situ preconcentration of heavy metals ions. The D401 resin powder was employed as sorbent to capture Pb(2+), Cu(2+), Zn(2+), Cd(2+), Co(2+), and Ni(2+), and then they desorbed with 2 mol/L nitric acid as eluent. Under the optimized conditions, these heavy metals ions in West Lake, Taihu Lake, and Yangtze River of China were captured and then determined by ICP-OES with the recovery of 92.5% to 111.5%. The on-site solid-phase extraction achieved a quick preconcentration of heavy metals to avoid the transport and storage of a large volume water sample. It is suitable for in situ monitoring of water quality in mountains, tablelands or other remote areas.

  2. Superfluid-insulator transition in a disordered two-dimensional quantum rotor model with random on-site interactions

    Science.gov (United States)

    An, Taeyang; Cha, Min-Chul

    2013-03-01

    We study the superfluid-insulator quantum phase transition in a disordered two-dimensional quantum rotor model with random on-site interactions in the presence of particle-hole symmetry. Via worm-algorithm Monte Carlo calculations of superfluid density and compressibility, we find the dynamical critical exponent z ~ 1 . 13 (2) and the correlation length critical exponent 1 / ν ~ 1 . 1 (1) . These exponents suggest that the insulating phase is a incompressible Mott glass rather than a Bose glass.

  3. Evaluation of shallow-placed low pressure distribution systems in soils marginally suited for on-site waste treatment

    OpenAIRE

    Ijzerman, M. Marian

    1990-01-01

    Two shallow-placed low pressure distribution (LPD) systems were evaluated in soils that were marginally suited for a conventional on-site wastewater disposal system (OSWDS) because of low hydraulic conductivity and shallow depth of soil to bedrock. The soils used for this study were Edom (fine, illitic, mesic, Typic Hapludult) and Penn-Bucks soil (fine-loamy, mixed, mesic, ultic Hapludult). In the Edam soil, the LPD system was installed with four subsystem designs operating: a ...

  4. [On-site detection of bioterrorism-relevant agents : Rapid detection methods for viruses, bacteria and toxins - capabilities and limitations].

    Science.gov (United States)

    Stern, Daniel; Richter, Martin; Schrick, Livia; Lasch, Peter; Keeren, Kathrin; Polleichtner, Angela; Lemmer, Karin; Nitsche, Andreas; Grunow, Roland; Herzog, Christian; Dorner, Brigitte G; Schaade, Lars

    2016-12-01

    In Europe, besides the threat of terrorist attacks involving conventional methods such as explosive devices and automatic weapons, there is also a potential threat of terrorist groups using non-conventional material like biological agents in the scope of future attacks. Consequently, rapid and reliable detection systems for biological agents are being developed and tested continuously to inform crisis management. For environmental detection, a broad spectrum of different laboratory-based techniques has been developed for relevant biological agents. However for environmental samples, fast and reliable on-site detection methods are desired by first responders for rapid assessment.Based on different functional principles, generic, immunological and nucleic-acid-based on-site detection methods can be distinguished. Those should be facile, fast, sensitive, and specific. However, commercially available kits usually have limited sensitivity and often have not been validated independently. Furthermore in this context, the multitude of relevant biological agents that potentially have to be considered present in complex environmental matrices poses a serious challenge for reliable detection. Therefore, detailed knowledge of the specific scope of applications and the limitations of different analytical systems is necessary to evaluate the results obtained purposefully.The aim of this article is to provide an overview of the analytical principles, benefits and limitations of prevailing on-site environmental detection systems for bioterrorism-relevant viruses, bacteria and toxins. Despite promising developments the informative value of currently available on-site tests is still limited. Thus, expert laboratories have to conduct confirmatory testing.

  5. Efficient on-site degradation of high concentration of spent deicing fluids: A laboratory study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Strong, J.M. [Oak Ridge National Lab., TN (United States); Waltz, M. [REMTECH, Bridgeville, PA (United States)

    1997-10-01

    The on-site treatment of antifreeze compounds and aircraft deicing fluids (ethylene glycol and propylene glycol) will reduce disposal costs, decrease environmental impact, minimize the potential for additional spills/contamination and meet the goals of pollution prevention by reducing the amount of hazardous materials generated. The authors have identified bacteria that can degrade 1-10% glycol waste at room temperatures of ca. 23C. A second subculture was isolated that could degrade glycol waste at ca. 4C.

  6. Performance of a rapid, on-site human immunodeficiency virus antibody assay in a public health setting.

    OpenAIRE

    Kassler, W J; Haley, C; Jones, W. K.; Gerber, A R; E. J. Kennedy; George, J R

    1995-01-01

    Rapid, on-site human immunodeficiency virus (HIV) testing has the potential to improve the delivery of prevention services in publicly funded counseling and testing sites. The Single Use Diagnostic System (SUDS) HIV-1 is the only rapid enzyme immunoassay (EIA) approved for diagnostic use in the United States. To evaluate the feasibility of using SUDS in public clinics and to validate the test's performance in a public health laboratory, we conducted blinded SUDS testing on plasma sent for HIV...

  7. On-site and in situ remediation technologies applicable to petroleum hydrocarbon contaminated sites in the Antarctic and Arctic

    Directory of Open Access Journals (Sweden)

    Danielle Camenzuli

    2015-09-01

    Full Text Available Petroleum hydrocarbon contaminated sites, associated with the contemporary and legacy effects of human activities, remain a serious environmental problem in the Antarctic and Arctic. The management of contaminated sites in these regions is often confounded by the logistical, environmental, legislative and financial challenges associated with operating in polar environments. In response to the need for efficient and safe methods for managing contaminated sites, several technologies have been adapted for on-site or in situ application in these regions. This article reviews six technologies which are currently being adapted or developed for the remediation of petroleum hydrocarbon contaminated sites in the Antarctic and Arctic. Bioremediation, landfarming, biopiles, phytoremediation, electrokinetic remediation and permeable reactive barriers are reviewed and discussed with respect to their advantages, limitations and potential for the long-term management of soil and groundwater contaminated with petroleum hydrocarbons in the Antarctic and Arctic. Although these technologies demonstrate potential for application in the Antarctic and Arctic, their effectiveness is dependent on site-specific factors including terrain, soil moisture and temperature, freeze–thaw processes and the indigenous microbial population. The importance of detailed site assessment prior to on-site or in situ implementation is emphasized, and it is argued that coupling of technologies represents one strategy for effective, long-term management of petroleum hydrocarbon contaminated sites in the Antarctic and Arctic.

  8. European Council of Legal Medicine (ECLM) principles for on-site forensic and medico-legal scene and corpse investigation.

    Science.gov (United States)

    Cusack, D; Ferrara, S D; Keller, E; Ludes, B; Mangin, P; Väli, M; Vieira, N

    2017-07-01

    Forensic medical practitioners need to define the general principles governing procedures to be used for the on-site examination of a body where the death has occurred in unnatural, violent or suspicious circumstances. These principles should be followed whenever a medical expert is required to perform an on-site corpse inspection and should be utilised as a set of general guidelines to be adapted to the specific situation in hand and interpreted using common sense and scientific knowledge of the relevant procedures and facts of the case. The aim of these principles is to ensure that forensic evidence at the scene of a death is properly observed and assessed and all necessary relevant evidence gathered in order to ensure that a comprehensive report is available to the judicial authority (investigating judge or coroner) in the justice system. The on-site corpse inspection by a forensic practitioner is a mandatory and essential stage of the forensic and medico-legal autopsy, as it may provide important information for subsequent investigation stages.

  9. MACSTOR, an on-site, dry, spent-fuel storage system developed by AECL for use by U. S. utilities

    Energy Technology Data Exchange (ETDEWEB)

    Durante, R.; Feinroth, H.; Pattanyus, P. (AECL Technologies, Bethesda, MD (United States))

    1992-01-01

    The continuing delay in the U.S. Department of Energy's Yucca Mountain and monitored retrievable storage spent-fuel disposal and storage programs has prompted U.S. utilities to consider expanding on-site storage of spent reactor fuel. Long-term, on-site storage has certain advantages to U.S. utilities since it eliminates the need for costly and difficult shipping and puts control of the spent fuel completely under the direction of the owner-utility. AECL Technologies (AECL), through its research company and Canada deuterium uranium (CANDU) engineering services division, has been developing on-site storage for Canadian heavy water nuclear plants for almost 20 yr. AECL has developed a design for a dry storage unit, designated MACSTOR (modular air-cooled storage), that can accommodate U.S. light water reactor (LWR) fuel elements and could become a candidate for the U.S. market. This paper describes MACSTOR and its evolution from the original silos and CANSTOR system that was developed and used in Canada. These systems are subject to regulatory controls by the Atomic Energy Control Board of Canada and have proven to be safe, convenient, and cost effective.

  10. On-site veterinary medical evaluation and care of working dogs and horses at the 2012 Republican National Convention.

    Science.gov (United States)

    Chatfield, Jenifer A; Dewell, Reneé; Miranda, Astrid J; Wilcox, Stefania; Vannieuwenhoven, Ty J

    2015-09-01

    To describe on-site veterinary medical care for working dogs and horses deployed for the 2012 Republican National Convention (RNC) in Tampa, Fla, August 24 to 30, 2012. Retrospective case series. 130 dogs and 45 horses. Data collected included breed, age, history, task assignment, reason for evaluation, and physical examination findings. A patient encounter report was recorded each time an animal was seen by veterinary staff for a physical evaluation. 46 of the 130 (35%) dogs and all 45 (100%) horses underwent at least 1 on-site veterinary evaluation, for a total of 478 patient encounters. The most common reason for an on-site veterinary evaluation was a wellness check (446 patient encounters). On the basis of veterinary recommendations, 1 dog and 4 horses were removed from continued service for the duration of the event. In addition, 1 dog and 1 horse were removed from active service for 12 to 24 hours but allowed to return to service for the duration of the event following a veterinary reevaluation. Results suggested that working dogs and horses deployed for large planned events face different health concerns, compared with concerns previously reported for animals deployed following disasters. Pre-event planning and training of handlers and riders may have helped reduce the number of health concerns, particularly health concerns related to high heat.

  11. Power Sources for Ultra Low Power Electronics

    Science.gov (United States)

    2000-06-12

    DARPA asked JASON to examine the issue of power sources for low power electronics with a specific emphasis on the properties of nuclear batteries and...integrated power sources combining power and electronics. During the 1998 Summer Study a workshop was held to provide background for the study, with

  12. Power theories for improved power quality

    CERN Document Server

    Pasko, Marian

    2012-01-01

    Power quality describes a set of parameters of electric power and the load’s ability to function properly under specific conditions. It is estimated that problems relating to power quality costs the European industry hundreds of billions of Euros annually. In contrast, financing for the prevention of these problems amount to fragments of these costs. Power Theories for Improved Power Quality addresses this imbalance by presenting and assessing a range of methods and problems related to improving the quality of electric power supply. Focusing particularly on active compensators and the DSP based control algorithms, Power Theories for Improved Power Quality introduces the fundamental problems of electrical power. This introduction is followed by chapters which discuss: •‘Power theories’ including their historical development and application to practical problems, •operational principles of active compensator’s DSP control based algorithms using examples and results from laboratory research, and •t...

  13. Women, Power, and Libraries.

    Science.gov (United States)

    Schuman, Patricia Glass

    1984-01-01

    Discusses the concept of power in the context of women and the library profession, citing views of power by Max Weber, John Kenneth Galbraith, Letty Cottin Pogrebin, and Rosabeth Moss Kantor. Male power and female submission, defining power, organizing for power, and sharing power are highlighted. A 12-item bibliography is included. (EJS)

  14. Wind power - a power source now enabled by power electronics

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Iov, Florin

    2007-01-01

    energy at the end-user should be set up. Deregulation of energy has lowered the investment in larger power plants, which means the need for new electrical power sources may be increased in the near future. Two major technologies will play important roles to solve the future problems. One is to change...... the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. Another is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most emerging...... renewable energy sources, wind energy, which by means of power electronics are changing from being minor energy sources to be acting as important power sources in the energy system....

  15. Wind power - a power source now enabled by power electronics

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Iov, Florin

    2007-01-01

    energy at the end-user should be set up. Deregulation of energy has lowered the investment in larger power plants, which means the need for new electrical power sources may be increased in the near future. Two major technologies will play important roles to solve the future problems. One is to change...... renewable energy sources, wind energy, which by means of power electronics are changing from being minor energy sources to be acting as important power sources in the energy system....

  16. Dynamic power flow controllers

    Science.gov (United States)

    Divan, Deepakraj M.; Prasai, Anish

    2017-03-07

    Dynamic power flow controllers are provided. A dynamic power flow controller may comprise a transformer and a power converter. The power converter is subject to low voltage stresses and not floated at line voltage. In addition, the power converter is rated at a fraction of the total power controlled. A dynamic power flow controller controls both the real and the reactive power flow between two AC sources having the same frequency. A dynamic power flow controller inserts a voltage with controllable magnitude and phase between two AC sources; thereby effecting control of active and reactive power flows between two AC sources.

  17. 78 FR 48468 - M/A-Com Technology Solutions, Including On-Site Leased Workers of Kelly Temps and Aerotek CE...

    Science.gov (United States)

    2013-08-08

    ... Kelly Temps and Aerotek CE, Torrance, California; M/A-Com Technology Solutions, Including On-Site Leased Workers of Kelly Temps and Aerotek CE, Long Beach, California; Amended Certification Regarding Eligibility... Solutions, including on-site leased workers of Kelly Temps and Aerotek CE, Torrance, California. The...

  18. Frequent brief on-site simulation training and reduction in 24-h neonatal mortality--an educational intervention study.

    Science.gov (United States)

    Mduma, Estomih; Ersdal, Hege; Svensen, Erling; Kidanto, Hussein; Auestad, Bjørn; Perlman, Jeffrey

    2015-08-01

    "Helping Babies Breathe" (HBB) is a simulation-based educational program developed to help reduce perinatal mortality worldwide. A one-day HBB training course did not improve clinical management of neonates. The objective was to assess the impact of frequent brief (3-5 min weekly) on-site HBB simulation training on newborn resuscitation practices in the delivery room and the potential impact on 24-h neonatal mortality. Before/after educational intervention study in a rural referral hospital in Northern Tanzania. Baseline data was collected from 01.02.2010 to 31.01.2011 and post-intervention data from 01.02.2011 to 31.01.2012. All deliveries were observed by research assistants who recorded information about labor, newborn delivery room management, perinatal characteristics, and neonatal outcomes. A newborn simulator was placed in the labor ward and frequent brief HBB simulation training was implemented on-site; 3-min of weekly paired practice, assisted by local-trainers. Local-trainers also facilitated 40-min monthly re-trainings. Outcome measures were; delivery room management of newborns and 24-h neonatal outcomes (normal, admitted to a neonatal area, death, or stillbirths). There were 4894 deliveries pre and 4814 post-implementation of frequent brief simulation training. The number of stimulated neonates increased from 712(14.5%) to 785(16.3%) (p = 0.016), those suctioned increased from 634(13.0%) to 762(15.8%) (p ≤ 0.0005). Neonates receiving bag mask ventilation decreased from 357(7.3%) to 283(5.9%) (p = 0.005). Mortality at 24-h decreased from 11.1/1000 to 7.2/1000 (p = 0.040). On-site, brief and frequent HBB simulation training appears to facilitate transfer of new knowledge and skills into clinical practice and to be accompanied by a decrease in neonatal mortality. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    Science.gov (United States)

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  20. Environmental Assessment and Finding of No Significant Impact: On-Site Treatment of Low Level Mixed Waste

    Energy Technology Data Exchange (ETDEWEB)

    N/A

    1999-03-22

    The Department of Energy (DOE) has prepared an environmental assessment (EA) (DOE/EA-1292) to evaluate the proposed treatment of low level mixed waste (LLMW) at the Rocky Flats Environmental Technology Site (Site). The purpose of the action is to treat LLMW in order to meet the Land Disposal Restrictions specified by the Resource Conservation and Recovery Act and the waste acceptance criteria of the planned disposal site(s). Approximately 17,000 cubic meters (m{sup 3}) of LLMW are currently stored at the Site. Another 65,000 m{sup 3}of LLMW are likely to be generated by Site closure activities (a total of 82,000 m{sup 3} of LLMW). About 35,000 m{sup 3} can be directly disposed of off-site without treatment, and most of the remaining 47,000 m{sup 3} of LLMW can be treated at off-site treatment, storage, and disposal facilities. However, some LLMW will require treatment on-site, either because it does not meet shipping requirements or because off-site treatment is not available for these particular types of LLMW. Currently, this LLMW is stored at the Site pending the development and implementation of effective treatment processes. The Site needs to treat this LLMW on-site prior to shipment to off-site disposal facilities, in order to meet the DOE long-term objective of clean up and closure of the Site. All on-site treatment of LLMW would comply with applicable Federal and State laws designed to protect public health and safety and to enhance protection of the environment. The EA describes and analyzes the environmental effects of the proposed action (using ten mobile treatment processes to treat waste on-site), and the alternatives of treating waste onsite (using two fixed treatment processes), and of taking no action. The EA was the subject of a public comment period from February 3 to 24, 1999. No written or other comments regarding the EA were received.

  1. Advancing family health through the Garden of Eatin': on-site food gardens in early childhood education.

    Science.gov (United States)

    Chaufan, Claudia; Yeh, Jarmin; Sigal, Byron

    2015-04-01

    Nutritional practices develop over the life course. Developing healthy habits at an early age can contribute to combating increasing child obesity rates. Through a range of activities that rely on the presence of an on-site food garden, North Bay Children's Center (NBCC), an early childhood education program, has enacted a "culture of health" into all aspects of the curriculum to promote healthy eating practices among children, families, teachers and staff. NBCC's garden program serves as a model in early childhood education and as a community-based intervention to improve family health and prevent child obesity.

  2. Test methods for on-site measurement of resistivity of concrete: a RILEM TC-154 Technical recommendation

    Energy Technology Data Exchange (ETDEWEB)

    Polder, R. B. [TNO Building and Construction Research (Netherlands)

    2000-07-01

    Based on a first draft of a RILEM Technical Recommendation, this paper describes methods to assess concrete resistivity on site for purposes of corrosion and protection of reinforcement. The theoretical background of concrete resistivity, a geometry-dependent material property that describes the electrical resistance, is explained. Various arrangements that can be used to measure electrical resistivity non-destructively are described, and their practical aspects are discussed. Procedures for calibration are proposed and guidelines for the interpretation of results and reference values for various exposures and concrete compositions are given. 29 refs., 1 tab., 4 figs.

  3. Heat and particle transport in a one-dimensional hard-point gas model with on-site potential

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2015-05-01

    Full Text Available Heat and particle transport in a one-dimensional hard-point gas of elastically colliding particles are studied. In the nonequal mass case, due to the presence of on-site potential, the heat conduction of the model obeys the Fourier law and all the transport coefficients asymptotically approach constants in the thermodynamic limit. The thermoelectric figure of merit ZT increases slowly with the system length L and is proportional to the height of the potential barriers H in high H regime. These findings may serve as a guide for future theoretical and experimental studies.

  4. Performance evaluation of on-site oral fluid drug screening devices in normal police procedure in Germany.

    Science.gov (United States)

    Musshoff, Frank; Hokamp, Eva Große; Bott, Ulrich; Madea, Burkhard

    2014-05-01

    There is a need for quick and reliable methods for rapid screening of drug-influenced drivers on the roadside by police. Because the window of detection in oral fluid is more similar to blood than to urine, this matrix should therefore be appropriate for screening procedures. The performance of the Rapid STAT(®) (Mavand Solution GmbH, Mössingen, Germany), DrugWipe5/5+(®) (Securetec Detektions-Systeme AG, Brunnthal, Germany) and Dräger DrugTest(®) 5000 (Draeger Safety AG & Co. KGaA, Luebeck, Germany) on-site oral fluid devices was evaluated with random oral fluid specimens from car drivers in North Rhine-Westphalia (Germany). Additionally, some drivers were checked using an on-site urine device (DrugScreen(®), NAL von Minden, Regensburg, Germany). During a 11-month period, 1.212 drivers were tested. Both OF and urine on-site tests were compared to serum results. The following sensitivities were obtained by the oral fluid devices: THC 71% (DrugWipe(®)), 87% (Dräger), 91% (RapidSTAT); opiates 95% (Dräger), 100% (DrugWipe(®), RapidSTAT(®)); amphetamine 84% (DrugTest(®) 5000), 90% (RapidSTAT(®)), 100% (DrugTest(®) 5000); methamphetamine 50% (DrugTest(®) 5000), 100% (RapidSTAT(®)); cocaine 76% (DrugTest(®) 5000), 100% (DrugWipe(®), RapidSTAT(®)); methadone 33-63%, and benzodiazepines 0-33% (both with a low number of positives). THC specificity was especially low (29% [DrugWipe(®)] and 47% [DrugTest(®) 5000]) due to low cut-off concentrations. These data were similar to those obtained from the literature (e.g., DRUID project). The urine screening device showed a good sensitivity (THC 93%, opiate 94%, amphetamine 94%, methamphetamine 75% (low number of positives), cocaine 100%) and also an acceptable specificity (39%, 86%, 63%, 77%, 47%, respectively). Although oral fluid may be a useful matrix for on-site testing of drugged drivers, it is evident that oral fluid devices still show a lack of sensitivity (methamphetamine, benzodiazepines) and

  5. Power electronics for low power arcjets

    Science.gov (United States)

    Hamley, John A.; Hill, Gerald M.

    1991-01-01

    In anticipation of the needs of future light-weight low-power spacecraft, arcjet power electronics in the 100- to 400-W operating range were developed. Power topologies similar to those in the higher 2-kW and 5- to 30-kW power range were implemented, including a four-transistor bridge-switching circuit, current-mode pulse-width modulated control, and an output current averaging inductor with an integral pulse generation winding. Reduction of switching transients was accomplished using a low inductance power distribution network, and no passive snubber circuits were necessary for power switch protection. Phase shift control of the power bridge was accomplished using an improved pulse width modulation to phase shift converter circuit. These features, along with conservative magnetics designs, allowed power conversion efficiencies of greater than 92.5 percent to be achieved into resistive loads over the entire operating range of the converter.

  6. Cost Benefit Analysis of the Power Storage System Considering Outage Cost in the Deregulated Power Market

    Science.gov (United States)

    Tsuru, Hirokazu; Fujii, Yasumasa

    In this paper, the authors propose the mathematical model which derives the optimal operation strategies of an on-site power storage system through the use of stochastic dynamic programming technique. The model takes account of the variations and uncertainties of electricity market prices as well as the outage costs of power grid failures. The market price fluctuation is modeled with stochastic differential equation. The stochastic state transitions between normal and failed systems are modeled with exponential density functions. The derived optimal operation indicates that the economic value of the storage system may be increased substantially, if the avoided outage costs are explicitly taken into account. The results of the sensitivity analysis indicate that the most influential parameters are the magnitude of outage cost and the mean time to failure of power grid.

  7. Hardware Accelerated Power Estimation

    CERN Document Server

    Coburn, Joel; Raghunathan, Anand

    2011-01-01

    In this paper, we present power emulation, a novel design paradigm that utilizes hardware acceleration for the purpose of fast power estimation. Power emulation is based on the observation that the functions necessary for power estimation (power model evaluation, aggregation, etc.) can be implemented as hardware circuits. Therefore, we can enhance any given design with "power estimation hardware", map it to a prototyping platform, and exercise it with any given test stimuli to obtain power consumption estimates. Our empirical studies with industrial designs reveal that power emulation can achieve significant speedups (10X to 500X) over state-of-the-art commercial register-transfer level (RTL) power estimation tools.

  8. Switching power converters medium and high power

    CERN Document Server

    Neacsu, Dorin O

    2013-01-01

    An examination of all of the multidisciplinary aspects of medium- and high-power converter systems, including basic power electronics, digital control and hardware, sensors, analog preprocessing of signals, protection devices and fault management, and pulse-width-modulation (PWM) algorithms, Switching Power Converters: Medium and High Power, Second Edition discusses the actual use of industrial technology and its related subassemblies and components, covering facets of implementation otherwise overlooked by theoretical textbooks. The updated Second Edition contains many new figures, as well as

  9. Electrical Power Converter

    NARCIS (Netherlands)

    Ferreira, J.A.

    2014-01-01

    Electrical power converter for converting electrical power of a power source connected or connectable at an input to electrical DC-power at an output, wherein between the input and the output a first circuit of submodules is provided, wherein said first circuit of submodules and the power source for

  10. Power flow controller

    NARCIS (Netherlands)

    Ferreira, J.A.; Yuan, Z.; De Haan, S.W.H.

    2008-01-01

    The invention relates to a power flow controller, comprising at least one first converter coupled with a power transmission line, and at least one second converter coupled with a power source, wherein said power source operates at a predeter-mined first frequency and connects to the power transmissi

  11. Solar Powered Radioactive Air Monitoring Stations

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, J. Matthew; Bisping, Lynn E.; Gervais, Todd L.

    2013-10-30

    Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

  12. Rapid on-site TLC-SERS detection of four antidiabetes drugs used as adulterants in botanical dietary supplements.

    Science.gov (United States)

    Zhu, Qingxia; Cao, Yongbing; Cao, Yingying; Chai, Yifeng; Lu, Feng

    2014-03-01

    A novel facile method has been established for rapid on-site detection of antidiabetes chemicals used to adulterate botanical dietary supplements (BDS) for diabetes. Analytes and components of pharmaceutical matrices were separated by thin-layer chromatography (TLC) then surface-enhanced Raman spectroscopy (SERS) was used for qualitative identification of trace substances on the HPTLC plate. Optimization and standardization of the experimental conditions, for example the method used for preparation of silver colloids, the mobile phase, and the concentration of colloidal silver, resulted in a very robust and highly sensitive method which enabled successful detection when the amount of adulteration was as low as 0.001 % (w/w). The method was also highly selective, enabling successful identification of some chemicals in extremely complex herbal matrices. The established TLC-SERS method was used for analysis of real BDS used to treat diabetes, and the results obtained were verified by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS). The study showed that TLC-SERS could be used for effective separation and detection of four chemicals used to adulterate BDS, and would have good prospects for on-site qualitative screening of BDS for adulterants.

  13. Short-term microbial release during rain events from on-site sewers and cattle in a surface water source.

    Science.gov (United States)

    Aström, Johan; Pettersson, Thomas J R; Reischer, Georg H; Hermansson, Malte

    2013-09-01

    The protection of drinking water from pathogens such as Cryptosporidium and Giardia requires an understanding of the short-term microbial release from faecal contamination sources in the catchment. Flow-weighted samples were collected during two rainfall events in a stream draining an area with on-site sewers and during two rainfall events in surface runoff from a bovine cattle pasture. Samples were analysed for human (BacH) and ruminant (BacR) Bacteroidales genetic markers through quantitative polymerase chain reaction (qPCR) and for sorbitol-fermenting bifidobacteria through culturing as a complement to traditional faecal indicator bacteria, somatic coliphages and the parasitic protozoa Cryptosporidium spp. and Giardia spp. analysed by standard methods. Significant positive correlations were observed between BacH, Escherichia coli, intestinal enterococci, sulphite-reducing Clostridia, turbidity, conductivity and UV254 in the stream contaminated by on-site sewers. For the cattle pasture, no correlation was found between any of the genetic markers and the other parameters. Although parasitic protozoa were not detected, the analysis for genetic markers provided baseline data on the short-term faecal contamination due to these potential sources of parasites. Background levels of BacH and BacR makers in soil emphasise the need to including soil reference samples in qPCR-based analyses for Bacteroidales genetic markers.

  14. On-site tests to estimate aquifer permeability of drainage area of south caisson anchorage construction of Taizhou Bridge

    Institute of Scientific and Technical Information of China (English)

    Feng Zhaoxiang; Zhao Yanrong

    2011-01-01

    During the construction of the south caisson anchorage of Taizhou Bridge, the drainage area is located in the lower reaches of the Yangtze River and the permeability of stratums there is considerable. In order to maintain progress and guarantee safety during the sinking of the caisson, water should be drained in the initial period. Subsequently, detailed information about the aquifer permeability is required to make sure that the drainage will proceed successfully,which consequently necessitates the on-site estimation of the aquifer permeability in the drainage area. Therefore, the traditional pumping test and slug test are implemented respectively on site. The comparison of computational results of these two tests indicates that they are consistent overall. Notwithstanding, as slug test can be conducted with portable facilities in a short time and the manipulation is easy and few people need to be involved, the advantages of slug test is conspicuous compared with the traditional pumping test. It could be speculated that slug test will gain a prevalent application in the measurement of aquifer permeability in the future.

  15. On-site residence time in a driven diffusive system: violation and recovery of mean-field

    CERN Document Server

    Messelink, Joris J B; Vahabi, Mahsa; MacKintosh, Fred C; Sharma, Abhinav

    2016-01-01

    We investigate simple one-dimensional driven diffusive systems with open boundaries. We are interested in the average on-site residence time defined as the time a particle spends on a given site before moving on to the next site. Using mean-field theory, we obtain an analytical expression for the on-site residence times. By comparing the analytic predictions with numerics, we demonstrate that the mean-field significantly underestimates the residence time due to the neglect of time correlations in the local density of particles. The temporal correlations are particularly long-lived near the average shock position, where the density changes abruptly from low to high. By using Domain wall theory (DWT), we obtain highly accurate estimates of the residence time for different boundary conditions. We apply our analytical approach to residence times in a totally asymmetric exclusion process (TASEP), TASEP coupled to Langmuir kinetics (TASEP + LK), and TASEP coupled to mutually interactive LK (TASEP + MILK). The high ...

  16. An aptamer based lateral flow strip for on-site rapid detection of ochratoxin A in Astragalus membranaceus.

    Science.gov (United States)

    Zhou, Weilu; Kong, Weijun; Dou, Xiaowen; Zhao, Ming; Ouyang, Zhen; Yang, Meihua

    2016-06-01

    An aptamer based lateral flow strip based on competitive format was developed for on-site rapid detection of ochratoxin A (OTA) in Astragalus membranaceus. Some crucial parameters that might influence the sensitive detection, such as the characterization of the colloidal gold, size and shape of gold nanoparticles (AuNPs), amount of AuNPs-aptamer conjugate, migration rate and the addition amount of methanol, were investigated to provide the optimum assay performance. To perform the test, 1g sample was extracted with 2.5mL of methanol-water (80:20, v/v) and diluted by 4-fold running buffer to eliminate the matrix and methanol interferences. Under optimized conditions, the aptamer-based assay showed a visual limit of detection (LOD) of 1ngmL(-1), and with no significant cross-reactivity with several homologous toxins. The whole detection could be completed within 15min without special equipment because of available visual results. One out of nine A. membranaceus samples was found to be positive of OTA, which was in a good agreement with those obtained from LC-MS/MS analysis. The results demonstrated that the aptamer-based lateral flow assay could be used as a rapid, reliable, cost-effective and robust on-site screening technique for mycotoxins at trace level in complex matrices without special instrumentation.

  17. Rapid, on-site identification of explosives in nanoliter droplets using a UV reflected fiber optic sensor.

    Science.gov (United States)

    Li, Xin; Li, Qiang; Zhou, Hong; Hao, Hongxia; Wang, Tongzhou; Zhao, Songmin; Lu, Ying; Huang, Guoliang

    2012-11-02

    A portable UV (190-400 nm) spectrophotometric based reflected fiber optic sensor system is presented for the on-site detection and identification of explosives. A reflected fiber optic sensor for explosives analysis was developed, with low sample consumption (20-100 nL) and a wide concentration quantification range (1.1-250 mg L(-1)). Seven common explosives [pentaerythritol tetranitrate (PETN), trinitrophenylmethylnitramine (CE), trinitrotoluene (TNT), dinitrotoluene (DNT), picric acid (PA), cyclotetramethylenetetranitramine (HMX), cyclotrimethylenetrinitramine (RDX)] and a PETN-RDX mixture (to simulate the Semtex used in many terrorist bombings) were quantitatively analyzed and identified by the proposed system in less than 3s per test, with limits of detection (LOD) of 0.3 mg L(-1). Due to chemical interference problems in the UV wavelengths range, a novel feature matching algorithm (FMA) was proposed for explosive identification, which was proved to have higher specificity and better anti-interference ability. Real post-blast debris samples were analyzed by the proposed method, and the results were validated against an LC/MS/MS method. The rapid, cost-effective detection with low sample consumption and wide applicability achieved by this system is highly suitable for homeland security on-site applications, such as rapid sample screening in post-blast debris. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Paper-based analytical device for sampling, on-site preconcentration and detection of ppb lead in water.

    Science.gov (United States)

    Satarpai, Thiphol; Shiowatana, Juwadee; Siripinyanond, Atitaya

    2016-07-01

    A simple and cost effectiveness procedure based on a paper based analytical device (PAD) for sampling, on-site preconcentration and determination of Pb(II) in water samples was developed. The inkjet printing method was used for patterning of PAD. Colorimetric assay was developed on a PAD for Pb(II) detection in µgL(-1) level. This µgL(-1) level detection limit was achieved by in situ- and on-site preconcentration of Pb(II) onto adsorption filter paper disc with a home-made holder before color development. Water sample was loaded onto a circular filter paper coated with zirconium silicate in 3% sodium carboxymethylcellulose for Pb(II) preconcentration. Subsequently, sodium rhodizonate in tartrate buffer solution (pH 2.8) was used as colorimetric reagent for direct Pb(II) detection on a PAD. Detection was achieved by measuring the pink color and recorded by scanner or digital camera. ImageJ software was used for measuring grey scale values. The calibration curve was linear in the range of 10µgL(-1) and 100µgL(-1), with a detection limit of 10µgL(-1). The developed method was successfully applied to the determination of Pb(II) in drinking water, tap water and surface water near electronic waste storage and the results were compared with those by graphite furnace atomic absorption spectroscopy (GF-AAS) with good agreement.

  19. The influence of UV aging of a styrene/butadiene/styrene modified bitumen: comparison between laboratory and on site aging

    Energy Technology Data Exchange (ETDEWEB)

    Francoise Durrieu; Fabienne Farcas; Virginie Mouillet [Service Physico-chimie des Materiaux, Paris (France). Laboratoire Central des Ponts et Chaussees

    2007-07-15

    During the service life in a pavement, neat bitumen and modified bitumen age as the result of the mixing with aggregates, the process of laying, the climatic conditions and the traffic. Laboratory methods for simulating the short-term and long-term ageing (RTFOT and PAV, respectively) are standardized. None of them takes into account the influence of UV radiations. In the particular case of a pavement located in south France, a comparison is drawn through Fourier Transformed InfraRed (FTIR) analysis. Three types of ageing are compared: the standard simulated ageings, the actual on site ageing after 12 and 26 months of road service and the ageing when UV exposure in a weathering oven follows RTFOT simulation. According to carbonyle function evolution by FTIR spectroscopy, this work shows that for all tested binders, the same ageing level as the one simulated by PAV is reached in a few hours when a thin film of binder is submitted to UV exposure after RTFOT. It is also to be noted that the level of the on site ageing of a SBS Polymer modified Bitumen (PmB) reaches the simulated PAV ageing after 12 months of pavement life. 23 refs., 7 figs., 4 tabs.

  20. Integrated Smartphone-App-Chip System for On-Site Parts-Per-Billion-Level Colorimetric Quantitation of Aflatoxins.

    Science.gov (United States)

    Li, Xiaochun; Yang, Fan; Wong, Jessica X H; Yu, Hua-Zhong

    2017-09-05

    We demonstrate herein an integrated, smartphone-app-chip (SPAC) system for on-site quantitation of food toxins, as demonstrated with aflatoxin B1 (AFB1), at parts-per-billion (ppb) level in food products. The detection is based on an indirect competitive immunoassay fabricated on a transparent plastic chip with the assistance of a microfluidic channel plate. A 3D-printed optical accessory attached to a smartphone is adapted to align the assay chip and to provide uniform illumination for imaging, with which high-quality images of the assay chip are captured by the smartphone camera and directly processed using a custom-developed Android app. The performance of this smartphone-based detection system was tested using both spiked and moldy corn samples; consistent results with conventional enzyme-linked immunosorbent assay (ELISA) kits were obtained. The achieved detection limit (3 ± 1 ppb, equivalent to μg/kg) and dynamic response range (0.5-250 ppb) meet the requested testing standards set by authorities in China and North America. We envision that the integrated SPAC system promises to be a simple and accurate method of food toxin quantitation, bringing much benefit for rapid on-site screening.

  1. Wind Power - A Power Source Enabled by Power Electronics

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Chen, Zhe

    2004-01-01

    The global electrical energy consumption is still rising and there is a steady demand to increase the power capacity. The production, distribution and the use of the energy should be as technological efficient as possible and incentives to save energy at the end-user should be set up. The deregul......The global electrical energy consumption is still rising and there is a steady demand to increase the power capacity. The production, distribution and the use of the energy should be as technological efficient as possible and incentives to save energy at the end-user should be set up....... The deregulation of energy has lowered the investment in bigger power plants, which means the need for new electrical power sources may be very high in the near future. Two major technologies will play important roles to solve the future problems. One is to change the electrical power production sources from...... the conventional, fossil (and short term) based energy sources to renewable energy sources. The other is to use high efficient power electronics in power systems, power production and end-user application. This paper discuss the most emerging renewable energy source, wind energy, which by means of power...

  2. Wind power in modern power systems

    DEFF Research Database (Denmark)

    Chen, Zhe

    2013-01-01

    In recent years, wind power is experiencing a rapid growth, and large-scale wind turbines/wind farms have been developed and connected to power systems. However, the traditional power system generation units are centralized located synchronous generators with different characteristics compared...... with wind turbines. This paper presents an overview of the issues about integrating large-scale wind power plants into modern power systems. Firstly, grid codes are introduced. Then, the main technical problems and challenges are presented. Finally, some possible technical solutions are discussed....

  3. Kansas Power Plants

    Data.gov (United States)

    Kansas Data Access and Support Center — The Kansas Power Plants database depicts, as point features, the locations of the various types of power plant locations in Kansas. The locations of the power plants...

  4. Efficiency in reducing lost-time injuries of a nurse-based and a first-aid-based on-site medical facility.

    Science.gov (United States)

    Spangenberg, Søren; Mikkelsen, Kim L; Kines, Pete; Dyreborg, Johnny

    2005-01-01

    The purpose of the study was to evaluate the efficiency of two standards for on-site medical facilities in reducing lost-time injuries during the construction of the link across the Oresund sound between Sweden and Denmark. One medical facility employed licensed nurses, who had advanced medical assistance at their disposal. The other medical facility utilized first-aid-trained watchmen. The on-site medical facilities aimed both at providing immediate medical assistance to workers subjected to occupational injuries and at reducing lost worktime. The distributions of injuries treated on-site (the worker resumed work after treatment) and injuries sent to hospitals or to specialists were compared for each type of injury and for each category of injured body part. The on-site medical facilities dealt, in particular, with the treatment of ocular injuries (21%), wounds (21%), and sprains or strains (15%). The study showed a statistically significant on-site treatment (and resume work) rate ratio of 3.3 between the nurse-based (76%) and the first-aid-based (23%) medical facility. The construction of the Oresund Link shows a need for on-site medical facilities, particularly at remote construction sites, and that it is essential that the medical personnel have both the qualifications and authorization to treat site-specific workplace injuries effectively in order to obtain high on-site treatment rates.

  5. Power and Control in Kathmandu: A Comparison of Attempted Power, Actual Power, and Achieved Power.

    Science.gov (United States)

    Emery, Clifton R; Thapa, Sirjana; Wu, Shali

    2016-05-05

    We argue that the concept of power has been inadvertently sidelined in recent theory and research on husband violence. Three types of relationship power may matter with respect to husband violence: attempted power, actual power, and achieved power. Analyses of a randomly selected representative sample of 270 married or partnered women in Kathmandu showed that actual power was related to husband violence prevalence, severity, and injury. Achieved power was related to husband violence prevalence and severity, and attempted power was related to husband violence injury. Implications are discussed.

  6. Power Service Shops

    Data.gov (United States)

    Federal Laboratory Consortium — TVA's Power Service Shops provides expert repair and maintenance of power system components and large industrial equipment. With world-class maintenance facilities...

  7. Development of a thermoelectric self-powered residential heating system

    Science.gov (United States)

    Qiu, K.; Hayden, A. C. S.

    Self-powered heating equipment has the potential for high overall energy efficiency and can provide an effective means of providing on site power and energy security in residential homes. It is also attractive for remote communities where connection to the grid is not cost effective. Self-powered residential heating systems operate entirely on fuel combustion and do not need externally generated electricity. Excess power can be provided for other electrical loads. To realize this concept, one must develop a reliable and low maintenance means of generating electricity and integrate it into fuel-fired heating equipment. In the present work, a self-powered residential heating system was developed using thermoelectric power generation technology. A thermoelectric module with a power generation capacity of 550 W was integrated into a fuel-fired furnace. The thermoelectric module has a radial configuration that fits well with the heating equipment. The electricity generated is adequate to power all electrical components for a residential central heating system. The performance of the thermoelectric module was examined under various operating conditions. The effects of heat transfer conditions were studied in order to maximize electric power output. A mathematical model was established and used to look into the influence of heat transfer coefficients and other parameters on electric power output and efficiency.

  8. Rapid extraction of three instantaneous attributes in the application of high-density on-site seismic acquisition data quality control

    Science.gov (United States)

    Zhang, Y.; Tong, S.; Wang, L.; Li, L.

    2015-12-01

    It is very important to evaluate the quality of the acquired high-density seismic data on-site acquisition. Fast、quantitative data analysis method can help on-site quality control personnel to monitor the quality of data conveniently. It can also estimate the distribution characteristics of abnormal data. We can adjust the construction parameters in time and guide the on-site acquisition work based on the results of the analysis.Mass data have been acquired by high-density seismic acquisition. Work-load of on-site data analysis and process is increasing because of mass data. We need to analyze the quality of the data quickly and improve the accuracy of the result. In normal seismic data on-site acquisition, on-site quality control personnel usually use qualitative method to analyze seismic data so the analyzing result is affected by the experience of quality control personnel. On-site seismic data analysis method gradually develops from qualitative to quantitative. Now we estimate the quality of seismic data by statistical characters instead of experience. The result of estimate is more reliable.On-site processing software has some analysis method like amplitude analysis, frequency analysis, autocorrelation analysis, F-K analysis and so on. We can estimate the quality of seismic data based on the quantitative process. We can also use a simple method to get the three instantaneous attributes if we transform seismic data to complex domain. On-site seismic data can be analyzed and estimated by applicable attributes (e.g. instantaneous amplitude can be used to find out abnormal trace; quality control personnel can analyze the propagation of the wave field by instantaneous phase because both strong and weak signal can be displayed on the instantaneous phase diagram; Instantaneous frequency could reflect the frequency values of every moment, it can estimate the distribution of on-site seismic data's frequency characteristics quantitative). Transforming seismic data to

  9. Innovative AE and NDT techniques for on-site measurement of concrete and masonry structures state-of-the-art report of the RILEM technical committee 239-MCM

    CERN Document Server

    2016-01-01

    This volume, in which on-site measurements of concrete and masonry structures by NDT techniques are comprehensively summarized, focuses on the visualization procedure of the results measured. The research and its outcomes presented in this book treat applications of NDT techniques to on-site measurements. These on-site measurements have been marginally successful as each technique requires a particular analysis. In this regard, visualization and imaging of results are in great demand for practitioners and engineers for inspection. The book will therefore be of great value to the field. .

  10. Real-time and on-site γ-ray radiation response testing system for semiconductor devices and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Yifei, E-mail: Y.Mu@student.liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Zhao, Ce Zhou, E-mail: cezhou.zhao@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Qi, Yanfei, E-mail: yanfei.qi01@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Lam, Sang, E-mail: s.lam@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Zhao, Chun, E-mail: garyzhao@ust.hk [Nano and Advanced Materials Institute, Hong Kong University of Science and Technology, Kowloon (Hong Kong); Lu, Qifeng, E-mail: qifeng@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Cai, Yutao, E-mail: yutao.cai@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Mitrovic, Ivona Z., E-mail: ivona@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Taylor, Stephen, E-mail: s.taylor@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Chalker, Paul R., E-mail: pchalker@liverpool.ac.uk [Center for Materials and Structures, School of Engineering, University of Liverpool, Liverpool L69 3GH (United Kingdom)

    2016-04-01

    The construction of a turnkey real-time and on-site radiation response testing system for semiconductor devices is reported. Components of an on-site radiation response probe station, which contains a 1.11 GBq Cs{sup 137} gamma (γ)-ray source, and equipment of a real-time measurement system are described in detail for the construction of the whole system. The real-time measurement system includes a conventional capacitance–voltage (C–V) and stress module, a pulse C–V and stress module, a conventional current–voltage (I–V) and stress module, a pulse I–V and stress module, a DC on-the-fly (OTF) module and a pulse OTF module. Electrical characteristics of MOS capacitors or MOSFET devices are measured by each module integrated in the probe station under continuous γ-ray exposure and the measurement results are presented. The dose rates of different gate dielectrics are calculated by a novel calculation model based on the Cs{sup 137} γ-ray source placed in the probe station. For the sake of operators’ safety, an equivalent dose rate of 70 nSv/h at a given operation distance is indicated by a dose attenuation model in the experimental environment. HfO{sub 2} thin films formed by atomic layer deposition are employed to investigate the radiation response of the high-κ material by using the conventional C–V and pulse C–V modules. The irradiation exposure of the sample is carried out with a dose rate of 0.175 rad/s and ±1 V bias in the radiation response testing system. Analysis of flat-band voltage shifts (ΔV{sub FB}) of the MOS capacitors suggests that the on-site and real-time/pulse measurements detect more serious degradation of the HfO{sub 2} thin films compared with the off-site irradiation and conventional measurement techniques.

  11. Scaling up kangaroo mother care in South Africa: 'on-site' versus 'off-site' educational facilitation

    Directory of Open Access Journals (Sweden)

    van Rooyen Elise

    2008-07-01

    Full Text Available Abstract Background Scaling up the implementation of new health care interventions can be challenging and demand intensive training or retraining of health workers. This paper reports on the results of testing the effectiveness of two different kinds of face-to-face facilitation used in conjunction with a well-designed educational package in the scaling up of kangaroo mother care. Methods Thirty-six hospitals in the Provinces of Gauteng and Mpumalanga in South Africa were targeted to implement kangaroo mother care and participated in the trial. The hospitals were paired with respect to their geographical location and annual number of births. One hospital in each pair was randomly allocated to receive either 'on-site' facilitation (Group A or 'off-site' facilitation (Group B. Hospitals in Group A received two on-site visits, whereas delegates from hospitals in Group B attended one off-site, 'hands-on' workshop at a training hospital. All hospitals were evaluated during a site visit six to eight months after attending an introductory workshop and were scored by means of an existing progress-monitoring tool with a scoring scale of 0–30. Successful implementation was regarded as demonstrating evidence of practice (score >10 during the site visit. Results There was no significant difference between the scores of Groups A and B (p = 0.633. Fifteen hospitals in Group A and 16 in Group B demonstrated evidence of practice. The median score for Group A was 16.52 (range 00.00–23.79 and that for Group B 14.76 (range 07.50–23.29. Conclusion A previous trial illustrated that the implementation of a new health care intervention could be scaled up by using a carefully designed educational package, combined with face-to-face facilitation by respected resource persons. This study demonstrated that the site of facilitation, either on site or at a centre of excellence, did not influence the ability of a hospital to implement KMC. The choice of outreach

  12. Rapid Estimation of Macroseismic Intensity for On-site Earthquake Early Warning in Italy from Early Radiated Energ

    Science.gov (United States)

    Emolo, A.; Zollo, A.; Brondi, P.; Picozzi, M.; Mucciarelli, M.

    2015-12-01

    Earthquake Early Warning System (EEWS) are effective tools for the risk mitigation in active seismic regions. Recently, a feasibility study of a nation-wide earthquake early warning systems has been conducted for Italy considering the RAN Network and the EEW software platform PRESTo. This work showed that a reliable estimations in terms of magnitude and epicentral localization would be available within 3-4 seconds after the first P-wave arrival. On the other hand, given the RAN's density, a regional EEWS approach would result in a Blind Zone (BZ) of 25-30 km in average. Such BZ dimension would provide lead-times greater than zero only for events having magnitude larger than 6.5. Considering that in Italy also smaller events are capable of generating great losses both in human and economic terms, as dramatically experienced during the recent 2009 L'Aquila (ML 5.9) and 2012 Emilia (ML 5.9) earthquakes, it has become urgent to develop and test on-site approaches. The present study is focused on the development of a new on-site EEW metodology for the estimation of the macroseismic intensity at a target site or area. In this analysis we have used a few thousands of accelerometric traces recorded by RAN related to the largest earthquakes (ML>4) occurred in Italy in the period 1997-2013. The work is focused on the integral EW parameter Squared Velocity Integral (IV2) and on its capability to predict the peak ground velocity PGV and the Housner Intensity IH, as well as from these latters we parameterized a new relation between IV2 and the Macroseismic Intensity. To assess the performance of the developed on-site EEW relation, we used data of the largest events occurred in Italy in the last 6 years recorded by the Osservatorio Sismico delle Strutture, as well as on the recordings of the moderate earthquake reported by INGV Strong Motion Data. The results shows that the macroseismic intensity values predicted by IV2 and the one estimated by PGV and IH are in good agreement.

  13. Performance of a rapid, on-site human immunodeficiency virus antibody assay in a public health setting.

    Science.gov (United States)

    Kassler, W J; Haley, C; Jones, W K; Gerber, A R; Kennedy, E J; George, J R

    1995-11-01

    Rapid, on-site human immunodeficiency virus (HIV) testing has the potential to improve the delivery of prevention services in publicly funded counseling and testing sites. The Single Use Diagnostic System (SUDS) HIV-1 is the only rapid enzyme immunoassay (EIA) approved for diagnostic use in the United States. To evaluate the feasibility of using SUDS in public clinics and to validate the test's performance in a public health laboratory, we conducted blinded SUDS testing on plasma sent for HIV testing. From 19 March through 30 June 1993, 1,923 consecutive samples from a sexually transmitted diseases clinic and an HIV counseling and testing clinic were tested on site with SUDS. Tests done in the first two weeks with a malfunctioning centrifuge n = 402) and those done when there were excessively high temperatures in the laboratory (n = 53) were analyzed separately. Of 1,466 tests, 39 were positive by both SUDS and EIA (with Western blot [immunoblot] confirmation) and 7 were SUDS positive and EIA negative. Western blotting was used as the "gold standard" to adjudicate these discrepancies. There were no SUDS-negative and EIA-positive tests. Compared with that of EIA (with Western blot confirmation), the sensitivity of SUDS was 100% (95% confidence interval, 88.8 to 100%) and the specificity was 99.5% (95% confidence interval, 98.9 to 99.8%). The positive predictive value of SUDS was 88% in the STD clinic and 81% in the HIV counseling and testing clinic. There was a 7.7-fold increase in false positives, from 0.48 to 3.7%, when there was inadequate centrifugation and when the temperature exceeded the manufacturer's recommendations. Rapid, on-site HIV testing by the SUDS assay is feasible and practical in public health settings. The test can be performed accurately, at reasonable cost, and within the time frame of a typical clinic visit. Caution should be used, however, as two conditions adversely affected the accuracy of this test: inadequate specimen preparation and

  14. Present on Site

    DEFF Research Database (Denmark)

    Ingemann, Bruno

    Why are exhibitions and museums so important? What can they be used for? Who determines relevance in a transformative process? Transforming exhibitions is not just something you do, it is something that gets better the more you do it. This book looks at the intersection of the visitor or user, wh...

  15. Development of a gas-cylinder-free plasma desorption/ionization system for on-site detection of chemical warfare agents.

    Science.gov (United States)

    Iwai, Takahiro; Kakegawa, Ken; Aida, Mari; Nagashima, Hisayuki; Nagoya, Tomoki; Kanamori-Kataoka, Mieko; Miyahara, Hidekazu; Seto, Yasuo; Okino, Akitoshi

    2015-06-02

    A gas-cylinder-free plasma desorption/ionization system was developed to realize a mobile on-site analytical device for detection of chemical warfare agents (CWAs). In this system, the plasma source was directly connected to the inlet of a mass spectrometer. The plasma can be generated with ambient air, which is drawn into the discharge region by negative pressure in the mass spectrometer. High-power density pulsed plasma of 100 kW could be generated by using a microhollow cathode and a laboratory-built high-intensity pulsed power supply (pulse width: 10-20 μs; repetition frequency: 50 Hz). CWAs were desorbed and protonated in the enclosed space adjacent to the plasma source. Protonated sample molecules were introduced to the mass spectrometer by airflow through the discharge region. To evaluate the analytical performance of this device, helium and air plasma were directly irradiated to CWAs in the gas-cylinder-free plasma desorption/ionization system and the protonated molecules were analyzed by using an ion-trap mass spectrometer. A blister agent (nitrogen mustard 3) and nerve gases [cyclohexylsarin (GF), tabun (GA), and O-ethyl S-2-N,N-diisopropylaminoethyl methylphosphonothiolate (VX)] in solution in n-hexane were applied to the Teflon rod and used as test samples, after solvent evaporation. As a result, protonated molecules of CWAs were successfully observed as the characteristic ion peaks at m/z 204, 181, 163, and 268, respectively. In air plasma, the limits of detection were estimated to be 22, 20, 4.8, and 1.0 pmol, respectively, which were lower than those obtained with helium plasma. To achieve quantitative analysis, calibration curves were made by using CWA stimulant dipinacolyl methylphosphonate as an internal standard; straight correlation lines (R(2) = 0.9998) of the peak intensity ratios (target per internal standard) were obtained. Remarkably, GA and GF gave protonated dimer ions, and the ratios of the protonated dimer ions to the protonated

  16. A novel fixed fibre biofilm membrane process for on-site greywater reclamation requiring no fouling control.

    Science.gov (United States)

    Jabornig, Simon; Podmirseg, Sabine Marie

    2015-03-01

    On-site greywater treatment and reuse in urban areas bears the potential to reduce huge quantities of wastewater and lower freshwater shortages. Until now dissemination of small, single household applications has been rather limited as simple and high quality water producing, but also cost-effective treatment units have not been developed so far. This paper proposes a new process, based on a concurrently working hollow-fibre membrane as fixed biofilm support and filtration device. Bioreactor characteristics, influence of different aeration rates, membrane flux development, as well as structure and composition of biofilm were monitored to evaluate the performance of the tested pilot unit. The introduced process achieved international water reuse guidelines, worked soundly and could, compared to conventional micro MBR, significantly reduce energy demand (greywater treatment and provides valuable design data for future optimization and systematic analysis.

  17. Design and field-scale implementation of an "on site" bioremediation treatment in PAH-polluted soil.

    Science.gov (United States)

    Pelaez, A I; Lores, I; Sotres, A; Mendez-Garcia, C; Fernandez-Velarde, C; Santos, J A; Gallego, J L R; Sanchez, J

    2013-10-01

    An "on site" bioremediation program was designed and implemented in soil polluted with polycyclic aromatic hydrocarbons (PAHs), especially naphthalene. We began by characterizing the soil's physical and chemical properties. A microbiological screening corroborated the presence of microorganisms capable of metabolizing PAHs. We then analyzed the viability of bioremediation by developing laboratory microcosms and pilot scale studies, to optimize the costs and time associated with remediation. The treatment assays were based on different types of biostimulants, such as a slow or fast-release fertilizer, combined with commercial surfactants. Once the feasibility of the biostimulation was confirmed, a real-scale bioremediation program was undertaken in 900 m(3) of contaminated soil. The three-step design reduced PAH contamination by 94.4% at the end of treatment (161 days). The decrease in pollutants was concomitant with the selection of autochthonous bacteria capable of degrading PAHs, with Bacillus and Pseudomonas the most abundant genera.

  18. Measurement of 37Ar to support technology for On-Site Inspection under the Comprehensive Nuclear-Test-BanTreaty

    Science.gov (United States)

    Aalseth, C. E.; Day, A. R.; Haas, D. A.; Hoppe, E. W.; Hyronimus, B. J.; Keillor, M. E.; Mace, E. K.; Orrell, J. L.; Seifert, A.; Woods, V. T.

    2011-10-01

    On-Site Inspection (OSI) is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclide isotopes created by an underground nuclear explosion are a valuable signature of a Treaty violation. Argon-37 is produced by neutron interaction with calcium in soil, 40Ca( n, α) 37Ar. For OSI, the 35-day half-life of 37Ar provides both high specific activity and sufficient time for completion of an inspection before decay limits sensitivity. This paper presents a low-background internal-source gas proportional counter with an 37Ar measurement sensitivity level equivalent to 45 mBq/SCM in wholeair.

  19. Measurement of 37Ar to support technology for On-site Inspection under the Comprehensive Nuclear-Test-Ban Treaty

    CERN Document Server

    Aalseth, C E; Haas, D A; Hoppe, E W; Hyronimus, B J; Keillor, M E; Mace, E K; Orrell, J L; Seifert, A; Woods, V T

    2010-01-01

    On-Site Inspection (OSI) is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclide isotopes created by an underground nuclear explosion are a valuable signature of a Treaty violation. Argon-37 is produced from neutron interaction with calcium in soil, 40Ca(n,{\\alpha})37Ar. For OSI, the 35-day half-life of 37Ar provides both high specific activity and sufficient time for completion of an inspection before decay limits sensitivity. This paper presents a low-background internal-source gas proportional counter with an 37Ar measurement sensitivity level equivalent to 45.1 mBq/SCM in whole air.

  20. On-site measurement of trace-level sulfide in natural waters by vapor generation and microchannel collection.

    Science.gov (United States)

    Toda, Kei; Kuwahara, Haruka; Ohira, Shin-Ichi

    2011-07-01

    Aqueous sulfide plays an important role in the environment even at low concentrations. However, it is unstable, which means field samples cannot be transported to the laboratory for analysis without fixation. In this work, a novel method was developed to determine trace levels of sulfide on site. This method is based on vapor generation and collection in a special microchannel device followed by fluorescence measurement (VG-μGAS). The microchannel scrubber gave a high enrichment factor, and a high sensitivity was achieved, which allowed measurement of nanomolar (nM) levels of sulfide. The theoretical approach to vapor generation for several compounds is discussed to evaluate the applicability of the method to these analytes, and compounds having a low Henry's law constant (Ariake Sea and Lake Baikal.

  1. A Discussion of Procedures and Equipment for the Comprehensive Test Ban Treaty On-Site Inspection Environmental Sampling and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wogman, Ned A.; Milbrath, Brian D.; Payne, Rosara F.; Seifert, Carolyn E.; Friese, Judah I.; Miley, Harry S.; Bowyer, Ted W.; Hanlen, Richard C.; Onishi, Yasuo; Hayes, James C.; Wigmosta, Mark S.

    2011-02-01

    This paper is intended to serve as a scientific basis to start discussions of the available environmental sampling techniques and equipment that have been used in the past that could be considered for use within the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) on-site inspections (OSI). This work contains information on the techniques, equipment, costs, and some operational procedures associated with environmental sampling that have actually been used in the past by the United States for the detection of nuclear explosions. This paper also includes a discussion of issues, recommendations, and questions needing further study within the context of the sampling and analysis of aquatic materials, atmospheric gases, atmospheric particulates, vegetation, sediments and soils, fauna, and drill-back materials.

  2. The organization and on-site follow-up of the electrical installation work for the LHC

    CERN Document Server

    Vairo, A

    2003-01-01

    The activity of the EL-WO section has two main purposes: manage the on-site installation works and carry out complete commissioning tests for all the new electrical installations, including those for the LHC accelerator. The management of installation works covers several aspects as: logistic, safety, coordination with other non-electrical works, follow-up of the planning. The testing of all the installation before the commissioning involves a close collaboration with the exploitation service and with the project leaders. This document describes the way of operating of the section and how these activities are carried out within the mainframe of the global ST division organization. It also describes the interfaces to the others actors of the LHC installation, such as: the contractors, the LHC installation working group, the ST/EL project leaders and the exploitation service of the electrical network.

  3. US DOE-EM On-Site Disposal Cell Working Group - Fostering Communication On Performance Assessment Challenges

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, Roger R. [Savannah River Site (SRS), Aiken, SC (United States); Suttora, Linda C. [U.S. Department of Energy, Office of Site Restoration, Germantown, MD (United States); Phifer, Mark [Savannah River Site (SRS), Aiken, SC (United States)

    2014-03-01

    On-site disposal cells are in use and being considered at several U.S. Department of Energy (USDOE) sites as the final disposition for large amounts of waste associated with cleanup of contaminated areas and facilities. These facilities are typically developed with regulatory oversight from States and/or the US Environmental Protection Agency (USEPA) in addition to USDOE. The facilities are developed to meet design standards for disposal of hazardous waste as well as the USDOE performance based standards for disposal of radioactive waste. The involvement of multiple and different regulators for facilities across separate sites has resulted in some differences in expectations for performance assessments and risk assessments (PA/RA) that are developed for the disposal facilities. The USDOE-EM Office of Site Restoration formed a working group to foster improved communication and sharing of information for personnel associated with these Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) disposal cells and work towards more consistent assumptions, as appropriate, for technical and policy considerations related to performance and risk assessments in support of a Record of Decision and Disposal Authorization Statement. The working group holds teleconferences, as needed, focusing on specific topics of interest. The topics addressed to date include an assessment of the assumptions used for performance assessments and risk assessments (PA/RAs) for on-site disposal cells, requirements and assumptions related to assessment of inadvertent intrusion, DOE Manual 435.1-1 requirements, and approaches for consideration of the long-term performance of liners and covers in the context of PAs. The working group has improved communication among the staff and oversight personnel responsible for onsite disposal cells and has provided a forum to identify and resolve common concerns.

  4. Evaluation of the Pavement Quality Indicator (PQI for the on-site density measurement of asphalt emulsion mixes

    Directory of Open Access Journals (Sweden)

    Martínez-Echevarría, M. J.

    2013-03-01

    Full Text Available The Pavement Quality Indicator (PQI is a non-nuclear gauge used for the on-site density measurement of asphalt pavements without the need to extract core samples. Previous studies of hot asphalt mixes found that PQI density readings were very similar to laboratory density measurements of pavement cores. This paper describes the first stage of a research project whose objective is to analyze PQI density measurements of mixes manufactured with an asphalt emulsion binder. The PQI density variability for such mixes was verified and compared with the results obtained with other on-site methods for measuring pavement density.

    El equipo Pavement Quality Indicator es un dispositivo para la determinación de densidad in situ en pavimentos asfálticos sin extracción de testigos. Las experiencias con este equipo en mezclas bituminosas en caliente, recogidas en diferentes fuentes bibliográficas, muestran que las densidades medidas in situ con el PQI son muy similares a las obtenidas mediante la extracción de testigos. En este artículo se expone la primera etapa de un proyecto de investigación que tiene por objeto analizar los resultados de mediciones efectuadas con PQI en mezclas bituminosas donde se utiliza emulsión asfáltica como ligante. Se comprueba la variabilidad de la densidad obtenida con el equipo para este tipo de mezclas, y se comparan los resultados con otros métodos de medida de densidad in situ.

  5. Orientations and other features of the Neolithic 'giants' churches' of Finland from on-site and lidar observations

    Science.gov (United States)

    Ridderstad, M. P.

    2015-07-01

    The orientations and placement of 52 Neolithic stone enclosures in Finland known as 'Giants' Churches' were analysed. In addition, other characteristic features, such as cairns and standing stones in or near the Giants' Churches, were investigated. The axis and gate orientations of the structures were measured using both on-site and airborne laser scanning (lidar) observations. The results showed lidar observations to be useful in archaeoastronomical analysis as a complementary tool to be used with on-site measurements and observations. The Giants' Churches were found to be orientations towards certain solar and lunar events that could have acted as 'seasonal pointers'. The orientations of the gates of the GCs were found to replicate the axis orientations to a large degree. The majority (over 90%) of the GCs were positioned on the eastern or southeastern side of the ridge they were built on, indicating the interest of the builders in the eastern horizon and possibly the rising of celestial bodies. The orientations of large (>35-m long) Giants' Churches and small (≤35-m long) ones were compared. The observed differences in the orientations of these two groups suggested that the structures traditionally known as Giants' Churches may be a heterogeneous group consisting of at least two types of structures represented in this study by the two selected size groups. Many large GCs were found to have been oriented towards the solstices, while the smaller ones did not show this feature. It is possible that the smaller Giants' Churches were oriented towards the Moon, while the larger ones were associated to solar events. The smaller Giants' Churches could be the remains of large houses or otherwise belong to a different tradition of construction.

  6. Electronic couplings and on-site energies for hole transfer in DNA: Systematic quantum mechanical/molecular dynamic study

    Science.gov (United States)

    Voityuk, Alexander A.

    2008-03-01

    The electron hole transfer (HT) properties of DNA are substantially affected by thermal fluctuations of the π stack structure. Depending on the mutual position of neighboring nucleobases, electronic coupling V may change by several orders of magnitude. In the present paper, we report the results of systematic QM/molecular dynamic (MD) calculations of the electronic couplings and on-site energies for the hole transfer. Based on 15ns MD trajectories for several DNA oligomers, we calculate the average coupling squares ⟨V2⟩ and the energies of basepair triplets XG +Y and XA +Y, where X, Y =G, A, T, and C. For each of the 32 systems, 15 000 conformations separated by 1ps are considered. The three-state generalized Mulliken-Hush method is used to derive electronic couplings for HT between neighboring basepairs. The adiabatic energies and dipole moment matrix elements are computed within the INDO/S method. We compare the rms values of V with the couplings estimated for the idealized B-DNA structure and show that in several important cases the couplings calculated for the idealized B-DNA structure are considerably underestimated. The rms values for intrastrand couplings G-G, A-A, G-A, and A-G are found to be similar, ˜0.07eV, while the interstrand couplings are quite different. The energies of hole states G+ and A+ in the stack depend on the nature of the neighboring pairs. The XG +Y are by 0.5eV more stable than XA +Y. The thermal fluctuations of the DNA structure facilitate the HT process from guanine to adenine. The tabulated couplings and on-site energies can be used as reference parameters in theoretical and computational studies of HT processes in DNA.

  7. Passive Fluidic Chip Composed of Integrated Vertical Capillary Tubes Developed for On-Site SPR Immunoassay Analysis Targeting Real Samples

    Directory of Open Access Journals (Sweden)

    Tsuneyuki Haga

    2012-05-01

    Full Text Available We have successfully developed a surface plasmon resonance (SPR measurement system for the on-site immunoassay of real samples. The system is composed of a portable SPR instrument (290 mm(W x 160 mm(D x 120 mm(H and a microfluidic immunoassay chip (16 mm(W x 16 mm(D x 4 mm(H that needs no external pump system. An integrated vertical capillary tube functions as a large volume (150 μL passive pump and a waste reservoir that has sufficient capacity for several refill operations. An immunoassay was carried out that employed the direct injection of a buffer and a test sample in sequence into a microfluidic chip that included 9 antibody bands and 10 reference reagent bands immobilized in the flow channel. By subtracting a reliable averaged reference sensorgram from the antibody, we effectively reduced the influence of the non-specific binding, and then our chip successfully detected the specific binding of spiked IgG in non-homogeneous milk. IgG is a model antigen that is certain not to be present in non-homogeneous milk, and non-homogeneous milk is a model of real sample that includes many interfering foreign substances that induce non-specific binding. The direct injection of a real sample with no pretreatment enabled us to complete the entire immunoassay in several minutes. This ease of operation and short measuring time are acceptable for on-site agricultural, environmentaland medical testing.

  8. Characterization and remediation of soil prior to construction of an on-site disposal facility at Fernald

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Jones, G. [Fluor Daniel Fernald, Inc., Cincinnati, OH (United States). Fernald Environmental Management Project; Janke, R. [Dept. of Energy (United States); Nelson, K. [Jacobs Engineering (United States)

    1998-03-01

    During the production years at the Feed Materials Production Center (FMPC), the soil of the site and the surrounding areas was surficially impacted by airborne contamination. The volume of impacted soil is estimated at 2.2 million cubic yards. During site remediation, this contamination will be excavated, characterized, and disposed of. In 1986 the US Environmental Protection Agency (EPA) and the Department of Energy (DOE) entered into a Federal Facility Compliance Agreement (FFCA) covering environmental impacts associated with the FMPC. A site wide Remedial Investigation/Feasibility Study (RI/FS) was initiated pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act, as amended by the Superfund Amendments and Reauthorization Act (CERCLA). The DOE has completed the RI/FS process and has received approval of the final Records of Decision. The name of the facility was changed to the Fernald Environmental Management Project (FEMP) to emphasize the change in mission to environmental restoration. Remedial actions which address similar scopes of work or types of contaminated media have been grouped into remedial projects for the purpose of managing the remediation of the FEMP. The Soil Characterization and Excavation Project (SCEP) will address the remediation of FEMP soils, certain waste units, at- and below-grade material, and will certify attainment of the final remedial limits (FRLs) for the FEMP. The FEMP will be using an on-site facility for low level radioactive waste disposal. The facility will be an above-ground engineered structure constructed of geological material. The area designated for construction of the base of the on-site disposal facility (OSDF) is referred to as the footprint. Contaminated soil within the footprint must be identified and remediated. Excavation of Phase 1, the first of seven remediation areas, is complete.

  9. Electronic couplings and on-site energies for hole transfer in DNA: systematic quantum mechanical/molecular dynamic study.

    Science.gov (United States)

    Voityuk, Alexander A

    2008-03-21

    The electron hole transfer (HT) properties of DNA are substantially affected by thermal fluctuations of the pi stack structure. Depending on the mutual position of neighboring nucleobases, electronic coupling V may change by several orders of magnitude. In the present paper, we report the results of systematic QM/molecular dynamic (MD) calculations of the electronic couplings and on-site energies for the hole transfer. Based on 15 ns MD trajectories for several DNA oligomers, we calculate the average coupling squares V(2) and the energies of basepair triplets XG(+)Y and XA(+)Y, where X, Y=G, A, T, and C. For each of the 32 systems, 15,000 conformations separated by 1 ps are considered. The three-state generalized Mulliken-Hush method is used to derive electronic couplings for HT between neighboring basepairs. The adiabatic energies and dipole moment matrix elements are computed within the INDO/S method. We compare the rms values of V with the couplings estimated for the idealized B-DNA structure and show that in several important cases the couplings calculated for the idealized B-DNA structure are considerably underestimated. The rms values for intrastrand couplings G-G, A-A, G-A, and A-G are found to be similar, approximately 0.07 eV, while the interstrand couplings are quite different. The energies of hole states G(+) and A(+) in the stack depend on the nature of the neighboring pairs. The XG(+)Y are by 0.5 eV more stable than XA(+)Y. The thermal fluctuations of the DNA structure facilitate the HT process from guanine to adenine. The tabulated couplings and on-site energies can be used as reference parameters in theoretical and computational studies of HT processes in DNA.

  10. Development of Rapid Immune-gold Strip Kit for On-Site Diagnosis of Tomato spotted wilt virus

    Directory of Open Access Journals (Sweden)

    Ju-Yeon Yoon

    2014-03-01

    Full Text Available A rapid, user-friendly and simple immune-chromatographic dipstick kit named ‘rapid immune-gold strip’ (RIGS kit was developed in a novel single strip format to detect on-site detection of Tomato spotted wilt virus (TSWV. Immunoglobulin G (IgG from polyclonal antisera raised in rabbits against TSWV was purified through protein- A affinity chromatography and then the purified TSWV-IgG was conjugated to colloidal gold nano-particles which served as a test line on nitrocellulose membrane. Protein A that non-specifically binds to TSWV antibody was used as a control line on the same strip. The diagnosis process with the TSWV-RIGS involves simply grinding the suspect plant sample in a bag that contains the extraction buffer and inserting the strip the bag. Results can be seen in 2-5 minutes. The flow of the complexes of gold particles coated with TSWV-IgG and a crude sap from TSWV-infected pepper, tobacco and tomato plants resulted in intensive color formed on the test lines proportional to the concentrations of TSWV. The RIGS-TSWV kit did not show any cross-reactions against other tomato-infecting viruses unrelated to TSWV. These results indicate that the TSWV-RIGS kit is highly sensitive and is not required for laboratory training and experience prior to testing. The TSWV-RIGS kit is suitable for on-site detection of suspect TSWV-infected plants as well as for laboratory diagnosis.

  11. Human Power Empirically Explored

    NARCIS (Netherlands)

    Jansen, A.J.

    2011-01-01

    Harvesting energy from the users’ muscular power to convert this into electricity is a relatively unknown way to power consumer products. It nevertheless offers surprising opportunities for product designers; human-powered products function independently from regular power infrastructure, are conven

  12. Wind Power Now!

    Science.gov (United States)

    Inglis, David Rittenhouse

    1975-01-01

    The government promotes and heavily subsidizes research in nuclear power plants. Federal development of wind power is slow in comparison even though much research with large wind-electric machines has already been conducted. Unless wind power programs are accelerated it will not become a major energy alternative to nuclear power. (MR)

  13. Wind Power Now!

    Science.gov (United States)

    Inglis, David Rittenhouse

    1975-01-01

    The government promotes and heavily subsidizes research in nuclear power plants. Federal development of wind power is slow in comparison even though much research with large wind-electric machines has already been conducted. Unless wind power programs are accelerated it will not become a major energy alternative to nuclear power. (MR)

  14. Distributed Power Flow Controller

    NARCIS (Netherlands)

    Yuan, Z.

    2010-01-01

    In modern power systems, there is a great demand to control the power flow actively. Power flow controlling devices (PFCDs) are required for such purpose, because the power flow over the lines is the nature result of the impedance of each line. Due to the control capabilities of different types of P

  15. Distributed Power Flow Controller

    NARCIS (Netherlands)

    Yuan, Z.

    2010-01-01

    In modern power systems, there is a great demand to control the power flow actively. Power flow controlling devices (PFCDs) are required for such purpose, because the power flow over the lines is the nature result of the impedance of each line. Due to the control capabilities of different types of P

  16. Power oscillation damping controller

    DEFF Research Database (Denmark)

    2012-01-01

    A power oscillation damping controller is provided for a power generation device such as a wind turbine device. The power oscillation damping controller receives an oscillation indicating signal indicative of a power oscillation in an electricity network and provides an oscillation damping control...

  17. Optimal Power Flow with Power Flow Routers

    OpenAIRE

    2016-01-01

    Power flow routing is an emerging control paradigm for the dynamic control of electric power flows. In this paper, we propose a generic model of a power flow router (PFR) and incorporate it into the optimal power flow (OPF) problem. First, a generic PFR architecture is proposed to encapsulate the desired functions of PFRs. Then, the load flow model of PFRs is developed and incorporated into the OPF framework. To pursue global optimality of the non-convex PFR-incorporated OPF (PFR-OPF) problem...

  18. The electric power engineering handbook power systems

    CERN Document Server

    2012-01-01

    Power Systems, Third Edition (part of the five-volume set, The Electric Power Engineering Handbook) covers all aspects of power system protection, dynamics, stability, operation, and control. Under the editorial guidance of L.L. Grigsby, a respected and accomplished authority in power engineering, and section editors Andrew Hanson, Pritindra Chowdhuri, Gerry Sheble, and Mark Nelms, this carefully crafted reference includes substantial new and revised contributions from worldwide leaders in the field. This content provides convenient access to overviews and detailed information on a diverse arr

  19. Combined Heat and Power

    Science.gov (United States)

    CHP is on-site electricity generation that captures the heat that would otherwise be wasted to provide useful thermal energy such as steam or hot water than can be used for space heating, cooling, domestic hot water and industrial processes.

  20. Atmosphere: Power, Critique, Politics

    DEFF Research Database (Denmark)

    Albertsen, Niels

    2016-01-01

    This paper hans three interrelated parts. First, atmosphere is approached through the concept of power. Atmospheres 'grip' us directly or mediate power indirectly by manipulating moods and evoking emotions. How does atmosphere relate to different conceptions of power? Second, atmospheric powers m...... be critiqued. Which conception of critique can be involved? Third, critiquing atmospheric powers can generate political conflict. How does atmospheric disputes relate to conceptions of politics and the political?...

  1. Powering Future Naval Forces

    Science.gov (United States)

    2010-11-01

    Ground Renewable Expeditionary Energy System Bulk Heterojunction Solar Cell 9  Long endurance fuel cell power (26hr flight Nov 2009)  Low noise...Near Mid Long EMRG Solid State Lights for Submarines Power Node Switching Center Perovskite - based Pyroelectrics 3 Power & Energy Technologies...Fuel Power Generation Energy Storage Distribution& Control Power Loads Fuels Chemistry Alternative Fuels Gas Turbine Generators Fuel Cells Aircraft

  2. Mobile Uninterruptible Power Supply

    Science.gov (United States)

    Mears, Robert L.

    1990-01-01

    Proposed mobile unit provides 20 kVA of uninterruptible power. Used with mobile secondary power-distribution centers to provide power to test equipment with minimal cabling, hazards, and obstacles. Wheeled close to test equipment and system being tested so only short cable connections needed. Quickly moved and set up in new location. Uninterruptible power supply intended for tests which data lost or equipment damaged during even transient power failure.

  3. Exercise Intensity During Power Wheelchair Soccer.

    Science.gov (United States)

    Barfield, J P; Newsome, Laura; Malone, Laurie A

    2016-11-01

    To determine exercise intensity during power wheelchair soccer among a sample of persons with mobility impairments. Cross-sectional descriptive. On-site training facilities of multiple power wheelchair soccer teams. Participants with severe mobility impairments (N=30) (mean ± SD, age: 29.40±15.51y, body mass index: 24.11±6.47kg/m(2), power soccer experience: 7.91±3.93y, disability sport experience: 12.44±9.73y) were recruited from multiple power wheelchair soccer teams. Portable metabolic carts were used to collect oxygen consumption (V˙o2) data during resting and game play conditions. Average V˙o2 (expressed in metabolic equivalent tasks [METs]) during resting and game play conditions and rating of perceived exertion for game play. V˙o2 increased from 1.35±0.47 METs at rest to 1.81±0.65 METs during game play. This 34% increase in exercise intensity was significant (Pfunctional capacity and performance of daily living activities (ie, 1.5 METs). Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Experimental Verification and Integration of a Next Generation Smart Power Management System

    Science.gov (United States)

    Clemmer, Tavis B.

    With the increase in energy demand by the residential community in this country and the diminishing fossil fuel resources being used for electric energy production there is a need for a system to efficiently manage power within a residence. The Smart Green Power Node (SGPN) is a next generation energy management system that automates on-site energy production, storage, consumption, and grid usage to yield the most savings for both the utility and the consumer. Such a system automatically manages on-site distributed generation sources such as a PhotoVoltaic (PV) input and battery storage to curtail grid energy usage when the price is high. The SGPN high level control features an advanced modular algorithm that incorporates weather data for projected PV generation, battery health monitoring algorithms, user preferences for load prioritization within the home in case of an outage, Time of Use (ToU) grid power pricing, and status of on-site resources to intelligently schedule and manage power flow between the grid, loads, and the on-site resources. The SGPN has a scalable, modular architecture such that it can be customized for user specific applications. This drove the topology for the SGPN which connects on-site resources at a low voltage DC microbus; a two stage bi-directional inverter/rectifier then couples the AC load and residential grid connect to on-site generation. The SGPN has been designed, built, and is undergoing testing. Hardware test results obtained are consistent with the design goals set and indicate that the SGPN is a viable system with recommended changes and future work.

  5. Electric power. Avoiding a new accident as on the Drac river; Electricite. Pour eviter un nouvel accient du Drac

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    A new inter-ministerial decree has been prescribed in France, in order to avoid any repetition of an accident where school children were drowned on a riverside, following a water release from an upstream hydraulic plant: risk analysis on every plant of this type, regulation on site access and utilization, regulation on hydraulic plant operation conditions. Other news concern power transmission de-concentration, domestic equipment regulations, EDF international strategy, rural electric power management, researches on electric power storage

  6. Power in Households: Disentangling Bargaining Power

    NARCIS (Netherlands)

    R. Mabsout (Ramzi); I.P. van Staveren (Irene)

    2009-01-01

    textabstractIntroduction Within the household bargaining literature, bargaining power is generally understood in terms of economic resources, such as income or assets. Empirical analyses of women’s bargaining power in households in developed and developing countries find that, in general, higher fem

  7. Power, stability of power, and creativity

    NARCIS (Netherlands)

    Sligte, Daniel J.; de Dreu, Carsten K. W.; Nijstad, Bernard A.

    2011-01-01

    Power hierarchies are an essential aspect of social organization, create stability and social order, and provide individuals with incentives to climb the hierarchical ladder. Extending previous work on power and creativity, we put forward that this relationship critically depends on both the stabili

  8. Power barges ease Philippines power shortage

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1996-02-01

    The Navotas barge project has been a cornerstone in helping the Philippines through the power crisis that almost brought the economy to a standstill. Van der Horst`s stake in the project recently reached more than 240 MW with the delivery of the latest of its four power barges. (author)

  9. Green Power Partnership 100 Green Power Users

    Science.gov (United States)

    EPA's Green Power Partnership is a voluntary program designed to reduce the environmental impact of electricity generation by promoting renewable energy. Partners on this list use green power to meet 100 of their U.S. organization-wide electricity use.

  10. Man-entry grid and power substations in Germany; Begehbare Netz- und Uebergabestationen in Deutschland

    Energy Technology Data Exchange (ETDEWEB)

    Primus, Illo-Frank

    2010-11-15

    Since the first publication of an electrotechnical standard for factory-assembled stations in 1997, grid and power substations in Germany as a rule are not constructed on site - with some exceptions, e.g. large-scale switching stations - but as prefabricated, factory-assembled concrete structures. There are two types of stations depending on the producer.

  11. Power and revenge.

    Science.gov (United States)

    Strelan, Peter; Weick, Mario; Vasiljevic, Milica

    2014-09-01

    We took an individual differences approach to explain revenge tendencies in powerholders. Across four experimental studies, chronically powerless individuals sought more revenge than chronically powerful individuals following a high power episode (Studies 1 and 2), when striking a powerful pose (Study 3), and when making a powerful hand gesture (Study 4). This relationship vanished when participants were not exposed to incidental power. A meta-analysis revealed that, relative to a lack of power or a neutral context, exposure to incidental power increased vengeance among the chronically powerless and reduced vengeance among the chronically powerful. These findings add to previous research on relations between power and aggression, and underscore the role of individual differences as a determinant of powerholders' destructive responses.

  12. Interaction of on-site and near real time measured turbidity and enzyme activity in stream water.

    Science.gov (United States)

    Stadler, Philipp; Farnleitner, Andreas H.; Zessner, Matthias

    2013-04-01

    On-site and on-line systems that provide an integrated surveillance of physicochemical and microbiological parameters gain significance in water quality monitoring. Particular relating to diffuse pollution from agricultural areas and use-orientated protection of waters the detection of faecal pollution is a fundamental part. For the near real time and on-site detection of microbiological faecal pollution of water, the beta-D- Glucuronidase (GLUC) enzymatic activity has been suggested as a surrogate parameter. Due to possible short measure intervals of three hours, this method has high potential as a water quality monitoring tool. While cultivation based standard determination takes more than one working day (Cabral 2010) the potential advantage of detecting the GLUC activity is the high temporal measuring resolution. Yet, there is still a big gap of knowledge on the sensitivity and specificity concerning the faecal indication capacity of GLUC in relation to standard assays (Cabral 2010). Interference effects of physicochemical parameters on the enzymatic activity respectively fluorescence have been discussed (Molina-Munoz et al. 2007; Tryland and Fiksdal 1998, Biswal et al. 2003). Results from a monitoring of a rivulet in an agricultural catchment in Lower Austria (HOAL - Hydrological Open Air Laboratory) are presented here. The HOAL offers technical resources that allow measurements at high temporal and spatial resolution and to apply various hydrological methods in one catchment. Two automated enzymatic measuring devices (Coliguard, mbOnline, Austria) and physicochemical in-stream measurements are used, as well as in-stream spectroscopy (spectrolyser, s::can, Austria). Accuracy of both enzymatic measuring devices is compared through diverse hydrological and seasonal conditions. Reference analyses by cultivation based determination were performed. Data from Coliguard devices is combined with physicochemical and spectroscopy data to gain information about the

  13. Power Electronics for Microgrids

    DEFF Research Database (Denmark)

    Dragicevic, Tomislav; Blaabjerg, Frede

    2016-01-01

    A microgrid (MG) is a stand-alone or grid-connected hybrid renewable system that uses distributed renewable and nonrenewable energy sources and energy storage systems (ESSs) to supply power to local loads. The system is ordinarily based on power electronics, with interface converters allowing...... a continuous supply of power in the presence of variable RES production. This chapter describes some specific features of DC MGs in terms of power architecture, control, and protection. It also reviews several uncommon power electronic interfaces. Regarding control, operation without critical communication...... are explained in this chapter. The chapter concludes with a review of power electronic intensive protection solutions for DC MGs....

  14. Electric power systems

    CERN Document Server

    Weedy, B M; Jenkins, N; Ekanayake, J B; Strbac, G

    2012-01-01

    The definitive textbook for Power Systems students, providing a grounding in essential power system theory while also focusing on practical power engineering applications. Electric Power Systems has been an essential book in power systems engineering for over thirty years. Bringing the content firmly up-to-date whilst still retaining the flavour of Weedy's extremely popular original, this Fifth Edition has been revised by experts Nick Jenkins, Janaka Ekanayake and Goran Strbac. This wide-ranging text still covers all of the fundamental power systems subjects but is now e

  15. Small scale power production

    Energy Technology Data Exchange (ETDEWEB)

    Muoniovaara, M. [IVO International Ltd, Vantaa (Finland)

    1996-12-31

    IVO International is a major constructor of biomass power plants in Finland and abroad. As a subsidiary of Imatran Voima Oy, the largest power utility in Finland, it has designed and constructed ten power plants owned by IVO Group or others capable of burning biomasses. Sizes of the plants vary from the world`s largest condensing peat-fired power plant of 155 MWe to a 6 MWe combined heat and power producing unit. This article describes the biomass power plants designed and constructed by IVO Group 3 refs.

  16. Shipboard electrical power systems

    CERN Document Server

    Patel, Mukund R

    2011-01-01

    Shipboard Electrical Power Systems addresses new developments in this growing field. Focused on the trend toward electrification to power commercial shipping, naval, and passenger vessels, this book helps new or experienced engineers master cutting-edge methods for power system design, control, protection, and economic use of power. Provides Basic Transferable Skills for Managing Electrical Power on Ships or on LandThis groundbreaking book is the first volume of its kind to illustrate optimization of all aspects of shipboard electrical power systems. Applying author Mukund Patel's rare combina

  17. Diagnostic difficulties and pitfalls in rapid on-site evaluation of endobronchial ultrasound guided fine needle aspiration

    Directory of Open Access Journals (Sweden)

    Monaco Sara

    2010-01-01

    Full Text Available Background: One of the novel techniques utilizing fine needle aspiration (FNA in the diagnosis of mediastinal and lung lesions is the endobronchial ultrasound (EBUS-guided FNA. In this study, we describe five cases which had a discrepancy between on-site evaluation and final diagnosis, or a diagnostic dilemma when rendering the preliminary diagnosis, in order to illustrate some of the diagnostic difficulties and pitfalls that can occur in EBUS FNA. Methods: A total of five EBUS FNA cases from five patients were identified in our records with a discrepancy between the rapid on-site evaluation (ROSE and final diagnosis, or that addressed a diagnostic dilemma. All of the cases had histological confirmation or follow-up. The cytomorphology in the direct smears, cell block, and immunohistochemical stains were reviewed, along with the clinical history and other available information. Results: Two cases were identified with a nondefinitive diagnosis at ROSE that were later diagnosed as malignant (metastatic signet-ring cell adenocarcinoma and metastatic renal cell carcinoma (RCC on the final cytological diagnosis. Three additional cases were identified with a ROSE and final diagnosis of malignant (large cell neuroendocrine carcinoma (LCNEC and two squamous cell carcinomas, but raised important diagnostic dilemmas. These cases highlight the importance of recognizing discohesive malignant cells and bland neoplasms on EBUS FNA, which may lead to a negative or a nondefinitive preliminary diagnosis. Neuroendocrine tumors can also be difficult due to the wide range of entities in the differential diagnosis, including benign lymphocytes, lymphomas, small and nonsmall cell carcinomas, and the lack of immunohistochemical stains at the time of ROSE. Finally, the background material in EBUS FNAs may be misleading and unrelated to the cells of interest. Conclusions: This study illustrates the cytomorphology of five EBUS FNA cases that address some of the

  18. On-site phytoremediation applicability assessment in Alur Ilmu, Universiti Kebangsaan Malaysia based on spatial and pollution removal analyses.

    Science.gov (United States)

    Mahmud, Mohd Hafiyyan; Lee, Khai Ern; Goh, Thian Lai

    2017-09-14

    The present paper aims to assess the phytoremediation performance based on pollution removal efficiency of the highly polluted region of Alur Ilmu urban river for its applicability of on-site treatment. Thirteen stations along Alur Ilmu were selected to produce thematic maps through spatial distribution analysis based on six water quality parameters of Malaysia's Water Quality Index (WQI) for dry and raining seasons. The maps generated were used to identify the highly polluted region for phytoremediation applicability assessment. Four free-floating plants were tested in treating water samples from the highly polluted region under three different conditions, namely controlled, aerated and normal treatments. The selected free-floating plants were water hyacinth (Eichhornia crassipes), water lettuce (Pistia stratiotes), rose water lettuce (Pistia sp.) and pennywort (Centella asiatica). The results showed that Alur Ilmu was more polluted during dry season compared to raining season based on the water quality analysis. During dry season, four parameters were marked as polluted along Alur Ilmu, namely dissolve oxygen (DO), 4.72 mg/L (class III); ammoniacal nitrogen (NH3-N), 0.85 mg/L (class IV); total suspended solid (TSS), 402 mg/L (class V) and biological oxygen demand (BOD), 3.89 mg/L (class III), whereas, two parameters were classed as polluted during raining season, namely total suspended solid (TSS), 571 mg/L (class V) and biological oxygen demand (BOD), 4.01 mg/L (class III). The thematic maps generated from spatial distribution analysis using Kriging gridding method showed that the highly polluted region was recorded at station AL 5. Hence, water samples were taken from this station for pollution removal analysis. All the free-floating plants were able to reduce TSS and COD in less than 14 days. However, water hyacinth showed the least detrimental effect from the phytoremediation process compared to other free-floating plants, thus made it a suitable free

  19. A partnership approach to providing on-site HIV services for probationers and parolees: a pilot study from Alabama, USA

    Directory of Open Access Journals (Sweden)

    Bronwen Lichtenstein

    2016-07-01

    Full Text Available Introduction: HIV in the United States is concentrated in the South, an impoverished region with marked health disparities and high rates of incarceration, particularly among African Americans. In the Deep South state of Alabama, a policy directive to reduce prison overcrowding has diverted large numbers of convicted felons to community supervision. Probation and parole offices have yet to provide the HIV education and testing services that are offered in state prisons. This study sought to implement on-site HIV services for probationers and parolees through an intersectoral programme involving law enforcement, university and HIV agency employees. The three main objectives were to (1 involve probation/parole officers in planning, execution and assessment of the programme, (2 provide HIV education to the officers and (3 offer voluntary pretest HIV counselling and testing to probationers and parolees. Methods: The partnered programme was conducted between October and December 2015. Offenders who were recently sentenced to probation (“new offenders”, received HIV education during orientation. Offenders already under supervision prior to the programme (“current offenders” learned about the on-site services during scheduled office visits. Outcomes were measured through officer assessments, informal feedback and uptake of HIV services among offenders. Results: A total of 86 new and 249 current offenders reported during the programme (N=335. Almost one-third (31.4% of new offenders sought HIV testing, while only 3.2% of current offenders were screened for HIV. Refusals among current offenders invoked monogamy, time pressures, being tested in prison, fear of positive test results and concerns about being labelled as gay or unfaithful to women partners. Officers rated the programme as worthwhile and feasible to implement at other offices. Conclusions: The partnership approach ensured support from law enforcement and intersectoral cooperation

  20. Applicability of rapid and on-site measured enzyme activity for surface water quality monitoring in an agricultural catchment

    Science.gov (United States)

    Stadler, Philipp; Farnleitner, Andreas H.; Sommer, Regina; Kumpan, Monika; Zessner, Matthias

    2014-05-01

    For the near real time and on-site detection of microbiological fecal pollution of water, the measurement of beta-D- Glucuronidase (GLUC) enzymatic activity has been suggested as a surrogate parameter and has been already successfully operated for water quality monitoring of ground water resources (Ryzinska-Paier et al. 2014). Due to possible short measure intervals of three hours, this method has high potential as a water quality monitoring tool. While cultivation based standard determination takes more than one working day (Cabral 2010) the potential advantage of detecting the GLUC activity is the high temporal measuring resolution. Yet, there is still a big gap of knowledge on the fecal indication capacity of GLUC (specificity, sensitivity, persistence, etc.) in relation to potential pollution sources and catchment conditions (Cabral 2010, Ryzinska-Paier et al. 2014). Furthermore surface waters are a big challenge for automated detection devices in a technical point of view due to the high sediment load during event conditions. This presentation shows results gained form two years of monitoring in an experimental catchment (HOAL) dominated by agricultural land use. Two enzymatic measurement devices are operated parallel at the catchment outlet to test the reproducibility and precision of the method. Data from continuous GLUC monitoring under both base flow and event conditions is compared with reference samples analyzed by standardized laboratory methods for fecal pollution detection (e.g. ISO 16649-1, Colilert18). It is shown that rapid enzymatic on-site GLUC determination can successfully be operated from a technical point of view for surface water quality monitoring under the observed catchment conditions. The comparison of enzyme activity with microbiological standard analytics reveals distinct differences in the dynamic of the signals during event conditions. Cabral J. P. S. (2010) "Water Microbiology. Bacterial Pathogens and Water" International Journal of