WorldWideScience

Sample records for on-site pafc power

  1. 1000kW on-site PAFC power plant development and demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Satomi, Tomohide; Koike, Shunichi [Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA), Osaka (Japan); Ishikawa, Ryou [New Energy and Industrial Technology Development Organization (NEDO), Tokyo (Japan)

    1996-12-31

    Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA) and New Energy and Industrial Technology Development Organization (NEDO) have been conducting a joint project on development of a 5000kW urban energy center type PAFC power plant (pressurized) and a 1000kW on-site PAFC power plant (non-pressurized). The objective of the technical development of 1000kW on-site PAFC power plant is to realize a medium size power plant with an overall efficiency of over 70% and an electrical efficiency of over 36%, that could be installed in a large building as a cogeneration system. The components and system integration development work and the plant design were performed in 1991 and 1992. Manufacturing of the plant and installation at the test site were completed in 1994. PAC test was carried out in 1994, and generation test was started in January 1995. Demonstration test is scheduled for 1995 and 1996.

  2. Development of on-site PAFC stacks

    Energy Technology Data Exchange (ETDEWEB)

    Hotta, K.; Matsumoto, Y. [Kansai Electric Power Co., Amagasaki (Japan); Horiuchi, H.; Ohtani, T. [Mitsubishi Electric Corp., Kobe (Japan)

    1996-12-31

    PAFC (Phosphoric Acid Fuel Cell) has been researched for commercial use and demonstration plants have been installed in various sites. However, PAFC don`t have a enough stability yet, so more research and development must be required in the future. Especially, cell stack needs a proper state of three phases (liquid, gas and solid) interface. It is very difficult technology to keep this condition for a long time. In the small size cell with the electrode area of 100 cm{sup 2}, gas flow and temperature distributions show uniformity. But in the large size cell with the electrode area of 4000 cm{sup 2}, the temperature distributions show non-uniformity. These distributions would cause to be shorten the cell life. Because these distributions make hot-spot and gas poverty in limited parts. So we inserted thermocouples in short-stack for measuring three-dimensional temperature distributions and observed effects of current density and gas utilization on temperature.

  3. Development of a 200kW multi-fuel type PAFC power plant

    Energy Technology Data Exchange (ETDEWEB)

    Take, Tetsuo; Kuwata, Yutaka; Adachi, Masahito; Ogata, Tsutomu [NTT Integrated Information & Energy System Labs., Tokyo (Japan)

    1996-12-31

    Nippon Telegraph and Telephone Corporation (NFT) has been developing a 200 kW multi-fuel type PAFC power plant which can generate AC 200 kW of constant power by switching fuel from pipeline town gas to liquefied propane gas (LPG) and vice versa. This paper describes the outline of the demonstration test plant and test results of its fundamental characteristics.

  4. Demonstration of an on-site PAFC cogeneration system with waste heat utilization by a new gas absorption chiller

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Tatsuo [Tokyo Gas Company, LTD, Tokyo (Japan)

    1996-12-31

    Analysis and cost reduction of fuel cells is being promoted to achieve commercial on-site phosphoric acid fuel cells (on-site FC). However, for such cells to be effectively utilized, a cogeneration system designed to use the heat generated must be developed at low cost. Room heating and hot-water supply are the most simple and efficient uses of the waste heat of fuel cells. However, due to the short room-heating period of about 4 months in most areas in Japan, the sites having demand for waste heat of fuel cells throughout the year will be limited to hotels and hospitals Tokyo Gas has therefore been developing an on-site FC and the technology to utilize tile waste heat of fuel cells for room cooling by means of an absorption refrigerator. The paper describes the results of fuel cell cogeneration tests conducted on a double effect gas absorption chiller heater with auxiliary waste heat recovery (WGAR) that Tokyo Gas developed in its Energy Technology Research Laboratory.

  5. Evaluation of the performance degradation at PAFC effect of catalyst degradation on electrode performance

    Energy Technology Data Exchange (ETDEWEB)

    Nishizaki, K.; Uchida, H.; Watanabe, M. [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    Aiming commercialization of Phosphoric Acid Fuel Cell (PAFC) power plant, many researches and developments have been contributed. Over 20000 hours operations have been demonstrated by many PAFC power plants. But there is no effective method for the estimation of lifetime of electrochemical cells without a practical long-term operation. Conducted by New Energy and Industrial Technology Development Organization (NEDO), cooperative research projects aiming development of PAFC lifetime estimation method have started since 1995 FY in Japan. As part of this project, this work has been performed to clarify basic phenomena of the performance degradation at PAFCs jointly by Yamanashi University, Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA) and PAFC manufacturers (Toshiba Co., Mitsubishi Electric Co, Fuji Electric Co.). Among several main causes of the cell performance degradation, effects of catalyst degradation (reduction in metal surface area, dealloying, changes in catalyst support) on PAFC cathode performances are discussed in this work.

  6. Development of the electric utility dispersed use PAFC stack

    Energy Technology Data Exchange (ETDEWEB)

    Horiuchi, Hiroshi; Kotani, Ikuo [Mitsubishi Electric Co., Kobe (Japan); Morotomi, Isamu [Kansai Electric Power Co., Hyogo (Japan)] [and others

    1996-12-31

    Kansai Electric Power Co. and Mitsubishi Electric Co. have been developing the electric utility dispersed use PAFC stack operated under the ambient pressure. The new cell design have been developed, so that the large scale cell (1 m{sup 2} size) was adopted for the stack. To confirm the performance and the stability of the 1 m{sup 2} scale cell design, the short stack study had been performed.

  7. Influence of impurity gases and operating conditions on PAFC performance

    Energy Technology Data Exchange (ETDEWEB)

    Hirai, K.; Iwasa, N.; Suzuki, M.; Okada, O. [Osaka Gas Co., Ltd. (Japan)] [and others

    1996-12-31

    On-site Phosphoric Acid Fuel Cell (PAFC) Cogeneration system is installed at various test sites, such as at underground parking lot, within chemical plant premises and near urban streets. Since in the current PAFC system, cathode air is supplied to the cell with no particular pretreatment, impurity gases in the air might influence on cell performance. We have investigated the influence of various impurity gases in the cathode gas, on sub-scale single cells, and have found that NO{sub 2}, SO{sub 2} and toluene affect negatively on cell performance. The results of these experiments and the conceivable mechanism of these effects on cell degradation are reported. We have also investigated the influence of other operating parameters, such as temperature, current density, fuel utilization on cell performance. From these experiments, we have found that operating temperature is a significant factor, which mainly determines cell voltage decline rate. The results of sub-scale single cell tests and a short-stack verification test are also reported.

  8. Experiences with on-site power sources at KCB

    Energy Technology Data Exchange (ETDEWEB)

    Heijnen, B. M.A. [Borssele Nuclear Power Station, N.V. P.Z.E.M., Postbus 48, 4330 AA Middleburg (Netherlands)

    1986-02-15

    The design of the nuclear power station is of the late sixties. The experiences with the on-site power sources, signal processing and some of the resulting modifications of the design of the power plant are mentioned. In order to let the design satisfy as much as possible present ideas about safety, it was decided to realize a total new and Independent decay heat removal System. With this system a second independent on-site power System is at disposal in case of accident situations. (author)

  9. On-site tests on the nuclear power plants

    International Nuclear Information System (INIS)

    Morilhat, P.; Favennec, J.M.; Neau, P.; Preudhomme, E.

    1996-01-01

    On-site tests and experiments are performed by EDF Research and Development Division on the nuclear power plants to assess the behaviour of major components submitted to thermal and vibratory solicitations. On-going studies deal with the qualification of new nuclear power plant standard and with the feedback of plants under operation. The tests, particularly the investigation tests, correspond to large investments and entail an important data volume which must ensure the continuity over a long period of the order of magnitude of the in-service plant life (around 40 years). This paper addresses the on-site experimental activities, describes the means to be used, and gives an example: the qualification of SG of new 1450 MW nuclear power plants. (author)

  10. Development of the on-site power supply in German nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Simon, M. [Gesellschaft fuer Reaktorsicherheit - GRS mbH, Schwertnergasse 1, D-5000 Koeln 1, Cologne (Germany)

    1986-02-15

    The design of the on-site power supply is different in German Nuclear Power Plants, depending on age and size of the plant. The cause for this is the evolution of the safety requirements. The general development of the design of safety Systems, which resulted in a strict separation of redundant trains is also reflected in the design of the emergency power system and even the complete on-site power supply System. This will be demonstrated by different examples. The advantages of this design with respect to the availability of on-site power will be explained and verified by means of operating experience. (author)

  11. A proposal on siting counterplan of nuclear power plants

    International Nuclear Information System (INIS)

    Sasao, Hitoshi

    1980-01-01

    As for the nuclear power generation in Japan. 21 plants with 14.95 million kW capacity have started the operation in 14 years. It is equivalent to more than 12% of the total capacity of power stations. But the environment around the development of nuclear power generation becomes more and more strict recently, and the formation of the consensus of residents becomes a very large political problem. The lead time from the proposal of construction to the local community to the commencement of operation was 8 years and 1 month in the case of 10 nuclear power stations in operation, but it is extended to 15 years and 6 months in the case of 4 power stations under construction. The prefectures where nuclear power stations are located were seven at the end of 1970, and only three were added during 9 years thereafter. It shows the difficulty of the location of nuclear power stations in new prefectures. In order to attain 78 million kW of nuclear power generation by 1995, the location of 50 million kW must be decided in coming several years in view of the lead time. The progress of the studies in the Atomic Industrial Forum, the strengthening of security system in the sistricts concerned, the formation of open environment for informations, the improvement of the setup concerning the compensation to fishery and others, and the studies on the law concerning the special measures for the districts where nuclear facilities are located are discussed. (Kako, I.)

  12. On site power generation protects water supply for Ajax, Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Morsy, Mohamed

    2011-01-15

    The Ajax water supply plant treats and distribute water for the town of Ajax and the nearby City of Pickering and the operations staff manages two other treatment plants supplying the City of Oshawa and the Town of Whitby, and a dozen pumping stations, reservoirs and elevated tanks. The plant requires around 2 MW of continuous power to supply its 150,000 customers. Although local utility power is reliable, standby generators are mandated by the Ontario Ministry of the Environment. When power goes out problems can result in the plant and system. To avoid these, the Ajax plant staff selected Cummins Power Generation who delivered one 350 kW and two 1500 kW generator sets with automatic transfer switches and paralleling switchgear. These digital systems parallel and synchronize the generator sets with each other and with the utility, which allows the plant to provide continuous service. The plant is designed for twice its current capacity and is ready to handle future requirements.

  13. On-site power generation for the future

    Energy Technology Data Exchange (ETDEWEB)

    McCarroll, R.L.; Partanen, W.E. [Power Generating, Inc., Fort Worth, TX (United States)

    1993-12-31

    Power Generating, Inc. is developing a direct-fired gas turbine power system designed to operate on solid fuel. This presentation will summarize the results of the development work performed to date and will outline the program currently underway to demonstrate the technical and economic viability of a gas turbine fired on white wood and subsequently on coal. The presentation will describe testing already completed on a pressurized cyclonic burner which forms the external combustion stage for the solid fuel fired gas turbine and the testing that has been done on various fuels categorized as acceptable {open_quotes}fuels of choice{close_quotes} for the demonstration project. Also to be covered will be a discussion of the equipment to be used in the demonstration project, the reasons why specific pieces of equipment have been selected, and how they might be modified for the gas turbine application.

  14. On site selection of thermoelectric power plants in polluted environment

    International Nuclear Information System (INIS)

    Gheorghe, A.V.

    1992-01-01

    This paper discusses the environmental impact of combined heat-power plants. The selection of the site of these plants depends on the spatial distribution law of pollutants and their chemical interaction with environment. The solutions of a diffusion equation describing a system of chemically interacting pollutants are given and discussed. The environmental impacts are described in terms of wind and atmosphere stability, effective and built stack height and the source distance parameters. The optimal constructive solutions are judged upon the concentrations of sulfur and nitrogen oxides at the ground level which must be kept under the maximum admissible limit. (author). 8 figs

  15. Estimation of current density distribution of PAFC by analysis of cell exhaust gas

    Energy Technology Data Exchange (ETDEWEB)

    Kato, S.; Seya, A. [Fuji Electric Co., Ltd., Ichihara-shi (Japan); Asano, A. [Fuji Electric Corporate, Ltd., Yokosuka-shi (Japan)

    1996-12-31

    To estimate distributions of Current densities, voltages, gas concentrations, etc., in phosphoric acid fuel cell (PAFC) stacks, is very important for getting fuel cells with higher quality. In this work, we leave developed a numerical simulation tool to map out the distribution in a PAFC stack. And especially to Study Current density distribution in the reaction area of the cell, we analyzed gas composition in several positions inside a gas outlet manifold of the PAFC stack. Comparing these measured data with calculated data, the current density distribution in a cell plane calculated by the simulation, was certified.

  16. Evaluation of the performance degradation at PAFC effect of electrolyte fill-level on electrode performance

    Energy Technology Data Exchange (ETDEWEB)

    Kitai, Takashi; Uchida, Hiroyuki; Watanabe, Masahiro [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    As a complimentary research project to the demonstration project of 5MW and 1MW PAFC plants, the mechanism and rate of deterioration of the cells and stacks have been studied from 1995 FY, with the objective of establishing an estimation method for the service life-time of the cell stacks. This work has been performed in the Basic Research Project, as part of that project on PAFC`s, selecting four subjects (Electrocatalysts degradation, Electrolyte fill-level, Cell material corrosion, Electrolyte loss) as the essential factors relating to the life-time. In this report, we will exhibit the effect of the electrolyte fill-level on the electrode performances.

  17. Assessment of On-Site Power Opportunities in the Industrial Sector; TOPICAL

    International Nuclear Information System (INIS)

    Bryson, T.

    2001-01-01

    The purpose of this report is to identify the potential for on-site power generation in the U.S. industrial sector with emphasis on nine industrial groups called the ''Industries of the Future'' (IOFs) by the U.S. Department of Energy (DOE). Through its Office of Industrial Technologies (OIT), the DOE has teamed with the IOFs to develop collaborative strategies for improving productivity, global competitiveness, energy usage and environmental performance. Total purchases for electricity and steam for the IOFs are in excess of$27 billion annually. Energy-related costs are very significant for these industries. The nine industrial groups are: (1) Agriculture (SIC 1); (2) Forest products; (3) Lumber and wood products (SIC 24); (4) Paper and allied products (SIC 26); (5) Mining (SIC 11, 12, 14); (6) Glass (SIC 32); (7) Petroleum (SIC 29); (8) Chemicals (SIC 28); and (9) Metals (SIC 33)-Steel, Aluminum, Metal casting. Although not currently part of the IOF program, the food industry is included in this report because of its close relationship to the agricultural industry and its success with on-site power generation. On-site generation provides an alternative means to reduce energy costs, comply with environmental regulations, and ensure a reliable power supply. On-site generation can ease congestion in the local utility's electric grid. Electric market restructuring is exacerbating the price premium for peak electricity use and for reliability, creating considerable market interest in on-site generation

  18. Evolution of the on-site electric power sources on French 900 MWe PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Bera, Jean [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, Departement d' Analyse de Surete, Service d' Analyse Fonctionnelle, Institut de Protection et Surete Nucleaire, B.P. No. 6, 92260 Fontenay-aux-Roses (France)

    1986-02-15

    Additional means have been provided on the French 900 MWe PWRs to improve safety if both the off-site and on-site Power sources are lost, namely: - a primary pump seal water injection device, one for two units; - a gas turbine generator for each site; - supplying any failing unit with electric power from a house load operating unit; - supplying a unit from a diesel generator of another unit. (author)

  19. Integration of a PAFC-Cogeneration Plant into an existing District-Heating-System

    International Nuclear Information System (INIS)

    Wagner, Ulrich; Geiger, Bernd; Grohmann, Juergen

    1999-01-01

    The Studiengesellschaft Brennstoffzellen e. V. assigned in the middle of 1995 the Institutions ''Lehrstuhl fir Energiewirtschaft mid Kraftwerkstechnik (IfE)'' to design a concept to integrate an ONSI-PAFC Model C in an existing district heating system. The fuel cell generates about 200 kW electrical and 215 kW thermal power consuming 500 kW natural gas. In the case of complete use of thermal power the fuel cell surpasses the efficiency of conventional systems by about 30 %. The possibilities to install the fuel cell were investigated at three locations, two housing areas, one with 36.000 m2 the other with 60.000 m2 heated area, and one indoor pool. The heating systems are representative of the Federal Republic of Germany. It turned out that the integration of the fuel cell into the existing heating system might be difficult at each location, either the annual consumption of thermal energy was too low or the heating system was operating at a temperature level reducing the usable thermal power of the fuel cell. After further studies the larger housing area was selected, with the intention of using the thermal power of the fuel cell during the whole year and to get high thermal load factors. Some difficulties are caused by the temperature level of the heating system, which is 70/55 o C. (author)

  20. Design characteristics of EU-APR1400 on-site power system

    International Nuclear Information System (INIS)

    Kim, D.H.; Kim, Y.S.; Kim, Y.S.

    2014-01-01

    In the global nuclear market, US and European design requirements have been largely used to develop the design of nuclear power plants(NPPs). The APR1400 design was developed on the basis of US regulatory guide and EPRI utility requirements document(URD). In order to enlarge the export market of APR1400, KHNP (Korea Hydro & Nuclear Power Co., Ltd) has developed the EU-APR1400 design which complies with the European nuclear design requirements. In this paper, the design characteristics of EU-APR1400 on-site power system developed according to the European design requirements of electrical power system are described. The European main design requirements of electrical power system involve 50 Hz rated frequency, 400/110 kV grid voltage, the application of the diversity and the redundancy, and so on. The EU-APR1400 on-site power system has been developed on the basis of these requirements. The representative designs include the redundancy, diversity, independence design, the emergency power supply design, the design for providing electrical power to the dedicated severe accident systems, and the design for European grid requirements. (author)

  1. Customer adoption of small-scale on-site power generation

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, Afzal S.; Marnay, Chris; Hamachi, Kristina S.; Rubio, F. Javier

    2001-04-01

    The electricity supply system is undergoing major regulatory and technological change with significant implications for the way in which the sector will operate (including its patterns of carbon emissions) and for the policies required to ensure socially and environmentally desirable outcomes. One such change stems from the rapid emergence of viable small-scale (i.e., smaller than 500 kW) generators that are potentially competitive with grid delivered electricity, especially in combined heat and power configurations. Such distributed energy resources (DER) may be grouped together with loads in microgrids. These clusters could operate semi-autonomously from the established power system, or macrogrid, matching power quality and reliability more closely to local end-use requirements. In order to establish a capability for analyzing the effect that microgrids may have on typical commercial customers, such as office buildings, restaurants, shopping malls, and grocery stores, an economic mod el of DER adoption is being developed at Berkeley Lab. This model endeavors to indicate the optimal quantity and type of small on-site generation technologies that customers could employ given their electricity requirements. For various regulatory schemes and general economic conditions, this analysis produces a simple operating schedule for any installed generators. Early results suggest that many commercial customers can benefit economically from on-site generation, even without considering potential combined heat and power and reliability benefits, even though they are unlikely to disconnect from the established power system.

  2. Customer adoption of small-scale on-site power generation

    International Nuclear Information System (INIS)

    Siddiqui, Afzal S.; Marnay, Chris; Hamachi, Kristina S.; Rubio, F. Javier

    2001-01-01

    The electricity supply system is undergoing major regulatory and technological change with significant implications for the way in which the sector will operate (including its patterns of carbon emissions) and for the policies required to ensure socially and environmentally desirable outcomes. One such change stems from the rapid emergence of viable small-scale (i.e., smaller than 500 kW) generators that are potentially competitive with grid delivered electricity, especially in combined heat and power configurations. Such distributed energy resources (DER) may be grouped together with loads in microgrids. These clusters could operate semi-autonomously from the established power system, or macrogrid, matching power quality and reliability more closely to local end-use requirements. In order to establish a capability for analyzing the effect that microgrids may have on typical commercial customers, such as office buildings, restaurants, shopping malls, and grocery stores, an economic mod el of DER adoption is being developed at Berkeley Lab. This model endeavors to indicate the optimal quantity and type of small on-site generation technologies that customers could employ given their electricity requirements. For various regulatory schemes and general economic conditions, this analysis produces a simple operating schedule for any installed generators. Early results suggest that many commercial customers can benefit economically from on-site generation, even without considering potential combined heat and power and reliability benefits, even though they are unlikely to disconnect from the established power system

  3. Evaluation of the performance degradation at PAFC effect of operating conditions on acid loss

    Energy Technology Data Exchange (ETDEWEB)

    Miyoshi, Hideaki; Uchida, Hiroyuki; Watanabe, Masahiro [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    As a complimentary research project to the demonstration project of 5MW and 1 MW PAFC plants, the mechanism and rate of deterioration of the cells and stacks have been studied from 1995 FY conducted by NEDO, with the objective of establishing an estimation method for the service life-time of the cell stacks. As part of this project, this work has been performed to clarify basic phenomena of the performance degradation at PAFCs jointly by Yamanashi University, PAFC-TRA and PAFC manufacturers. The acid loss into exhaust gases is one of life limiting factors in PAFCs. To design the cells of long-life, it is important to estimate the phosphoric acid loss and to contrive ideas eliminating it. With the objective of obtaining basic data for simulating the acid loss in the large size cells, the effect of the operating conditions on the acid loss into exhaust gases has been studied experimentally by using a single cell with an active electrode area of 100 cm{sup 2}.

  4. Recommended criteria for the evaluation of on-site nuclear power plant emergency exercises

    International Nuclear Information System (INIS)

    Lafortune, J.F.

    1997-01-01

    A review of existing Canadian and International emergency exercise evaluation criteria and approaches has been conducted. Based on the results of the review, criteria are proposed for the evaluation of on-site emergency exercises for Canadian nuclear power stations. The proposed criteria are performance-based. They are comprehensive, yet remain adaptable to all stations and accident scenarios. They are primarily aimed at radiological emergency exercises, but are entirely applicable to fire or other conventional exercises. This report also addresses evaluation preparation and methodology. (author). 21 refs., 6 tabs

  5. Operating experience relating to on-site electric power sources. Proceedings of a Specialist Meeting

    International Nuclear Information System (INIS)

    1986-02-01

    The reliability of on-site electric power sources of nuclear power plants usually consisting of diesel generators, gas turbine generators and DC power sources, has been a matter of concern during reactor operations. The frequent recurrence and the important consequences of failures relating to on-site electric power sources have led to a general consensus that they form one of the most significant features influencing the total performance of the safety Systems. This has also been confirmed by surveys performed on the incidents reported through the NEA Incident Reporting System (IRS). Accordingly, a recommendation to organise a Specialist Meeting on the subject was made at the third annual meeting of CSNI Principal Working Group No. 1 (Operating Experience and Human Factors). At the 12. meeting of the CSNI held in November 1984. the Committee endorsed the proposal and accepted an offer by the United Kingdom to host and organise the Specialist Meeting. The Specialist Meeting, sponsored by the CSNI, was held in London, United Kingdom from 16 to 18 October 1985. It was hosted by H.M. Nuclear Installations Inspectorate of the Health and Safety Executive. The purpose of the meeting was to promote the exchange of Information on operating experience relating to on-site electric power sources and to look for measures to further improve their reliability In the areas of design, operation and licensing. The meeting was organised by a Programme Group which included nominated members of CSNI PWG No. 1. the Programme Group met in May and June 1985 in Paris to agree on the programme and practical arrangements for the meeting. As a result of the review of the abstracts which had been contributed in response to the Call for Papers, 28 papers were accepted for presentation during the meeting. Approximately 60 delegates from 13 Member countries, and the NEA Secretariat, attended the meeting. Session summaries prepared by the respective session chairmen are Included prior to the

  6. Operating experience relating to on-site electric power sources. Proceedings of a Specialist Meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-02-15

    The reliability of on-site electric power sources of nuclear power plants usually consisting of diesel generators, gas turbine generators and DC power sources, has been a matter of concern during reactor operations. The frequent recurrence and the important consequences of failures relating to on-site electric power sources have led to a general consensus that they form one of the most significant features influencing the total performance of the safety Systems. This has also been confirmed by surveys performed on the incidents reported through the NEA Incident Reporting System (IRS). Accordingly, a recommendation to organise a Specialist Meeting on the subject was made at the third annual meeting of CSNI Principal Working Group No. 1 (Operating Experience and Human Factors). At the 12. meeting of the CSNI held in November 1984. the Committee endorsed the proposal and accepted an offer by the United Kingdom to host and organise the Specialist Meeting. The Specialist Meeting, sponsored by the CSNI, was held in London, United Kingdom from 16 to 18 October 1985. It was hosted by H.M. Nuclear Installations Inspectorate of the Health and Safety Executive. The purpose of the meeting was to promote the exchange of Information on operating experience relating to on-site electric power sources and to look for measures to further improve their reliability In the areas of design, operation and licensing. The meeting was organised by a Programme Group which included nominated members of CSNI PWG No. 1. the Programme Group met in May and June 1985 in Paris to agree on the programme and practical arrangements for the meeting. As a result of the review of the abstracts which had been contributed in response to the Call for Papers, 28 papers were accepted for presentation during the meeting. Approximately 60 delegates from 13 Member countries, and the NEA Secretariat, attended the meeting. Session summaries prepared by the respective session chairmen are Included prior to the

  7. Operating experience and licensing criteria relating to on-site electric power systems in Italy

    Energy Technology Data Exchange (ETDEWEB)

    Ciattaglia, S.; Grimaldi, G. [ENEA/DISP, Via Vitaliano Brancati, 48, 00144 Roma/Rome (Italy)

    1986-02-15

    The most significant events of on-site electrical power supply degradation in Italian plants took place in coincidence with severe atmospheric conditions or with the propagation of disturbances by lightning stroke inside the plant. Essential instrumentation was lost in two cases so that, for some time, no indication of the plant status was allowed. In both cases the recovery of the plant was achieved by restoration of external power supply. Corrective actions included both improvement in immunity to disturbances, redundancy, capability and physical separation and DG's reliability demonstration. Design and safety analysis of new plants are now carried out with the help of reliability studies and probabilistic risk assessment. As a result, design changes were performed on new plants to improve the reliability of DGs start-up and the independence of the electrical emergency divisions. (authors)

  8. Operating experience and licensing criteria relating to on-site electric power systems in Italy

    International Nuclear Information System (INIS)

    Ciattaglia, S.; Grimaldi, G.

    1986-01-01

    The most significant events of on-site electrical power supply degradation in Italian plants took place in coincidence with severe atmospheric conditions or with the propagation of disturbances by lightning stroke inside the plant. Essential instrumentation was lost in two cases so that, for some time, no indication of the plant status was allowed. In both cases the recovery of the plant was achieved by restoration of external power supply. Corrective actions included both improvement in immunity to disturbances, redundancy, capability and physical separation and DG's reliability demonstration. Design and safety analysis of new plants are now carried out with the help of reliability studies and probabilistic risk assessment. As a result, design changes were performed on new plants to improve the reliability of DGs start-up and the independence of the electrical emergency divisions. (authors)

  9. On-site electric power source facility for Japanese nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Oohara, T. [Incident/Failure Analysis and Evaluation Office, Nuclear Power Safety Information Research Centre, Nuclear Power Engineering Test Centre, 2nd Floor, Shuwa-Kamiyacho Bldg., 3-13, 4-Chome, Toranomon Minato-ku, Tokyo 105 (Japan)

    1986-02-15

    Trends of construction of nuclear power plants in Japan, occurrence rate of incidents/failures of electric facilities, major example of incidents/failures, their countermeasure to prevent recurrence are introduced. Furthermore, safety administration system of the Government, electric utilities and manufacturers, and various countermeasures to prevent incident/ failure of electrical facilities from the hardware and software sides are discussed. (author)

  10. On-site electric power source facility for Japanese nuclear power plant

    International Nuclear Information System (INIS)

    Oohara, T.

    1986-01-01

    Trends of construction of nuclear power plants in Japan, occurrence rate of incidents/failures of electric facilities, major example of incidents/failures, their countermeasure to prevent recurrence are introduced. Furthermore, safety administration system of the Government, electric utilities and manufacturers, and various countermeasures to prevent incident/ failure of electrical facilities from the hardware and software sides are discussed. (author)

  11. Facilities and medical care for on-site nuclear power plant radiological emergencies

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    The operation of a nuclear power plant introduces risks of injury or accidents that could also result in the exposure of personnel to radiation or radioactive materials. It is important in such an event to have adequate first aid and medical facilities, supplies, equipment, transportation capabilities and trained personnel available to provide necessary care. This standard provides guidance for first aid during an emergency and for initial medical care of those overexposed to penetrating radiation or contaminated with radioactive material or radionuclides. Recommendations cover facilities, supplies, equipment and the extent of care on-site, where first aid and initial care may be provided, and off-site at a local hospital, where further medical and surgical care may be provided. Additional recommendations are also provided for the transportation of patients and the training of personnel. A brief discussion of specialized care is provided in an appendix

  12. Enhancing nuclear power plant safety via on-site mental fatigue management

    Directory of Open Access Journals (Sweden)

    Tsai Ming-Kuan

    2017-01-01

    Full Text Available Nuclear incidents and accidents have occurred at various nuclear power plants. Since some of these incidents and accidents caused by human errors might be preventable, numerous researchers argue that fatigue management for on-site workers is the key, especially for mental fatigue. Thus, this study proposes an approach consisting of two mechanisms. A fatigue monitor could identify the mentally fatigued workers by detecting their brain wave rhythms through a brain-computer interface. For such workers, a fatigue alert would awaken them. If the status of the mentally fatigued workers becomes worse, based on a positioning technique (i.e., wireless networks, this mechanism would alert the nearby workers and managers to deal with this condition. The test results indicate that the proposed approach enhanced the capacity to examine the mentally fatigued workers, ensured the accuracy in locating these workers, and avoided possible nuclear incidents. This study is a useful reference for similar applications in the nuclear industry.

  13. Evaluation of reliability of on-site A.C. power systems based on maintenance records

    International Nuclear Information System (INIS)

    Basso, G.; Pia, S.; Fusari, W.; Soressi, G.; Vaccari, G.

    1986-01-01

    To the end of ascertain in what extent the evaluation of reliability of emergency diesel generators (D.G.) can be improved by means of a deeper knowledge of their operating history a study has been carried-out on 21 D.G. sets: 4 D.G. of the Caorso nuclear plant (BWR, 870 MWe) and 17 D.G. in service at 6 steam-electric fossil-fuelled plants. The major points of interest resulting from this study are: 1) reliability assessments of A.C. on-site power Systems, made on the basis of outcomes of surveillance tests, may lead to results which overestimate the real performance. 2) the unreliability of a redundant System of stand-by components is determined in large extent by unavailabilities due to scheduled and unscheduled maintenance, latent failures, tests. (authors)

  14. Evaluation of reliability of on-site A.C. power systems based on maintenance records

    Energy Technology Data Exchange (ETDEWEB)

    Basso, G.; Pia, S. [ENEA/TERM/VAOEC, C.R.E. Casaccla via Anguillarese, 00100 Roma/Rome (Italy); Fusari, W. [ENEL, Rome (Italy); Soressi, G.; Vaccari, G. [ENEL, Centro di Ricerca Termica e Nucl., Via Rubattino, 54, 1-20134 Mllano/Milan (Italy)

    1986-02-15

    To the end of ascertain in what extent the evaluation of reliability of emergency diesel generators (D.G.) can be improved by means of a deeper knowledge of their operating history a study has been carried-out on 21 D.G. sets: 4 D.G. of the Caorso nuclear plant (BWR, 870 MWe) and 17 D.G. in service at 6 steam-electric fossil-fuelled plants. The major points of interest resulting from this study are: 1) reliability assessments of A.C. on-site power Systems, made on the basis of outcomes of surveillance tests, may lead to results which overestimate the real performance. 2) the unreliability of a redundant System of stand-by components is determined in large extent by unavailabilities due to scheduled and unscheduled maintenance, latent failures, tests. (authors)

  15. On-site storage of spent nuclear fuel assemblies in German nuclear power plants

    International Nuclear Information System (INIS)

    Banck, J.

    1999-01-01

    The selection of back-end strategies for spent fuel assemblies is influenced by a number of different factors depending on the given situation in any specific country. In Germany, the back-end strategy implemented in the past was almost exclusively reprocessing. This strategy was required by the German Atomic Energy Act. Since 1994, when the Atomic Energy Act was amended, the option of direct final disposal has been granted the equivalent status by law to that afforded to reprocessing (and reuse of valuable materials). As a result, German utilities may now choose between these two alternatives. Another important condition for optimizing the back-end policy is the fact that fuel cycle costs in Germany are directly dependent on spent fuel volumes (in contrast to the US, for example, such costs are related to the amount of power generated). Another boundary condition for German utilities with respect to spent fuel management is posed by the problems with militant opponents of nuclear energy during transportation of spent fuel to interim storage sites. These facts have given rise to a reconsideration of the fuel cycle back-end, which has resulted in a change in strategy by most German utilities in favour of the following: Preference for long-term storage and maximized use of on-site storage capacity; Reduction in the amount of spent fuel by increasing burnup as much as possible. These decisions have also been driven by the deregulation of energy markets in Europe, where utilities are now permitted to sell electric power to consumers beyond their original supply network and must therefore offer electric power on a very cost competitive basis. (author)

  16. On-site quality assurance during erection of a nuclear power plant

    International Nuclear Information System (INIS)

    Mueller, J.

    1976-01-01

    The paper deals with general quality assurance measures, the quality assurance during on-site production (incoming inspection, inspection of welds and welding equipment) and describes in more detail the quality assurance procedures for the containment. (RW) [de

  17. Evaluation of the performance degradation at PAFC investigation of dealloying process of electrocatalysts with in-situ XRD

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Noriyuki; Uchida, Hiroyuki; Watanabe, Masahiro [Yamanashi Univ., Kofu (Japan)] [and others

    1996-12-31

    As a complementary research project to the demonstration project of 5MW and 1 MW PAFC plants, the mechanism and rate of deterioration of the cells and stacks have been studied from 1995 FY, with the objective of establishing an estimation method for the service life-time of the cell stacks. This work has been performed in the Basic Research Project, as part of that project on PAFC`s, selecting four subjects (Electrocatalysts degradation, Electrolyte fill-level, Cell material corrosion, Electrolyte loss) as the essential factors relating to the life-time. In this study, the effect of temperature and potential on the dealloying process of electrocatalysts was examined in H{sub 3}PO{sub 4} electrolyte with X-ray diffraction measurement.

  18. Guide to purchasing green power. Renewable electricity, renewable energy certificates and on-site renewable generation

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-09-30

    The Guide to Purchasing Green Power is intended for organizations that are considering the merits of buying green power as well as those that have decided to buy it and want help doing so. The Guide was written for a broad audience, including businesses, government agencies, universities, and all organizations wanting to diversify their energy supply and to reduce the environmental impact of their electricity use.The Guide provides an overview of green power markets and describes the necessary steps to buying green power. This section summarizes the Guide to help readers find the information they need.

  19. Proceedings of the symposium on the on-site management of power reactor wastes

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This symposium represents a synthesis of some current practices and research and development work in the field of radioactive waste management at nuclear power plants. It includes the following sessions: radioactive waste management practices at nuclear power plants; waste production and operating experiences; coolant and liquid waste processing; solidification methods; volume reduction methods; solid waste containment

  20. Review of Investigations on Site Selection for Nuclear Power Plants in Croatia

    International Nuclear Information System (INIS)

    Malbasa, N.

    2008-01-01

    A review of site investigation for nuclear facilities in the Republic of Croatia that had been performed from 1964, when investigation started for the first nuclear power plant, to 1994 when the activities were stopped, is presented therein. Brief results of the main investigation were presented including the Tanja site on the Danube upstream of Vukovar. It is the best of all the investigated locations for nuclear power plant in Croatia. The review of results for site selection of low and intermediate level of radioactive waste disposal is also given. The position of nuclear power plants in the strategic documents of the Republic of Croatia was analysed. It is concluded that the status of nuclear facilities in the main strategic documents must be improved because the energy future in Croatia - as almost in all European countries - could hardly be successful without any further development of nuclear energy.(author)

  1. Review of Investigations on Site Selection for Nuclear Power Plants in Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Malbasa, N [Ekonerg, Zagreb (Croatia)

    2008-07-01

    A review of site investigation for nuclear facilities in the Republic of Croatia that had been performed from 1964, when investigation started for the first nuclear power plant, to 1994 when the activities were stopped, is presented therein. Brief results of the main investigation were presented including the Tanja site on the Danube upstream of Vukovar. It is the best of all the investigated locations for nuclear power plant in Croatia. The review of results for site selection of low and intermediate level of radioactive waste disposal is also given. The position of nuclear power plants in the strategic documents of the Republic of Croatia was analysed. It is concluded that the status of nuclear facilities in the main strategic documents must be improved because the energy future in Croatia - as almost in all European countries - could hardly be successful without any further development of nuclear energy.(author)

  2. Stationary power fuel cell commercialization status worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Williams, M.C. [Dept. of Energy, Morgantown, WV (United States)

    1996-12-31

    Fuel cell technologies for stationary power are set to play a role in power generation applications worldwide. The worldwide fuel cell vision is to provide powerplants for the emerging distributed generation and on-site markets. Progress towards commercialization has occurred in all fuel cell development areas. Around 100 ONSI phosphoric acid fuel cell (PAFC) units have been sold, with significant foreign sales in Europe and Japan. Fuji has apparently overcome its PAFC decay problems. Industry-driven molten carbonate fuel cell (MCFC) programs in Japan and the U.S. are conducting megawatt (MW)-class demonstrations, which are bringing the MCFC to the verge of commercialization. Westinghouse Electric, the acknowledged world leader in tubular solid oxide fuel cell (SOFC) technology, continues to set performance records and has completed construction of a 4-MW/year manufacturing facility in the U.S. Fuel cells have also taken a major step forward with the conceptual development of ultra-high efficiency fuel cell/gas turbine plants. Many SOFC developers in Japan, Europe, and North America continue to make significant advances.

  3. Governor stability simulations of Svartisen power plant verified by the installed monitoring system on site

    International Nuclear Information System (INIS)

    Nielsen, T K; Kjeldsen, M

    2010-01-01

    Many Norwegian hydro power plants have complex lay-out with several reservoirs, broke intakes, surge shafts and even air cushion chambers. There are kilometers of excavated tunnels as well as long tail water systems. The stations are often equipped by multiple of turbines, both in series and parallel. A number of operation modes are therefore possible. Doing transient simulations and simulations of governor stability in the design phase, the problem is to find the worst case scenario regarding these operating modes. Svartisen power plant has been of particular interest these days. The power plant is originally designed for two 350 MW Francis turbines, however, only one turbine was installed. When designed, governor stability was regarded as problematic due to the long penstock. A long penstock will give a too high time constant for the hydraulic inertia. The main problem here is, however, the water hammer frequency that interferes with the governor performance. The frequency is in the same range as the cross frequency. Therefore the governor will react on these water hammer waves, which in its nature is notoriously unstable. The common solution is to build an air cushion and thereby increase the water hammer frequency above the cross frequency. The expenses were, however, deemed too high, and it was necessary to seek for other solutions. A pressure feedback on the governor was introduced in order to have stable operation at least for two turbines. With only one turbine installed, the pressure feedback has not been activated because, based on the simulations, it was regarded unnecessary. Even if the original simulations shows good stability margins when only one turbine is running, there has been some indications that the aggregate has suffered from instability. In 2004 Svartisen Power Plant was equipped with a comprehensive monitoring system. Both the turbine and the generator performance have been observed. This gives valuable information on how the hydropower

  4. Governor stability simulations of Svartisen power plant verified by the installed monitoring system on site

    Science.gov (United States)

    Nielsen, T. K.; Kjeldsen, M.

    2010-08-01

    Many Norwegian hydro power plants have complex lay-out with several reservoirs, broke intakes, surge shafts and even air cushion chambers. There are kilometers of excavated tunnels as well as long tail water systems. The stations are often equipped by multiple of turbines, both in series and parallel. A number of operation modes are therefore possible. Doing transient simulations and simulations of governor stability in the design phase, the problem is to find the worst case scenario regarding these operating modes. Svartisen power plant has been of particular interest these days. The power plant is originally designed for two 350 MW Francis turbines, however, only one turbine was installed. When designed, governor stability was regarded as problematic due to the long penstock. A long penstock will give a too high time constant for the hydraulic inertia. The main problem here is, however, the water hammer frequency that interferes with the governor performance. The frequency is in the same range as the cross frequency. Therefore the governor will react on these water hammer waves, which in its nature is notoriously unstable. The common solution is to build an air cushion and thereby increase the water hammer frequency above the cross frequency. The expenses were, however, deemed too high, and it was necessary to seek for other solutions. A pressure feedback on the governor was introduced in order to have stable operation at least for two turbines. With only one turbine installed, the pressure feedback has not been activated because, based on the simulations, it was regarded unnecessary. Even if the original simulations shows good stability margins when only one turbine is running, there has been some indications that the aggregate has suffered from instability. In 2004 Svartisen Power Plant was equipped with a comprehensive monitoring system. Both the turbine and the generator performance have been observed. This gives valuable information on how the hydropower

  5. Long-term commitment of Japanese gas utilities to PAFCs and SOFCs

    Science.gov (United States)

    Matsumoto, Kiyokazu; Kasahara, Komei

    Tokyo Gas and Osaka Gas have been committed to addressing the energy- and environment-related issues of Japan through promotion of natural gas, an energy friendly to the environment. Being aware of the diversifying market needs (e.g. efficient energy utilization, rising demand for electricity, etc.), active efforts have been made in marketing gas-fired air-conditioning and co-generation systems. In this process, a high priority has also been placed on fuel cells, particularly for realizing their market introduction. Since their participation in the TARGET Program in USA in 1972, the two companies have been involved with the field testing and operation of phosphoric acid fuel cells (PAFCs), whose total capacity has amounted to 12.4 MW. The two companies have played a vital role in promoting and accelerating fuel cell development through the following means: (1) giving incentives to manufacturers through purchase of units and testing, (2) giving feedback on required specifications and technical problems in operation, and (3) verifying and realizing long-term operation utilizing their maintenance techniques. It has been expected that the primary goal of the cumulative operation time of 40 000 h shall be achieved in the near future. Work has also been in progress to develop SOFC. In the joint R&D of a 25-kW solid oxide fuel cell (SOFC) with Westinghouse, the record operation time of 13 000 h has been achieved. Though still twice as much as the average price of competing equipment, the commercialization of PAFCs is close at hand. By utilizing government spending and subsidies for field testing, work will be continued to verify reliability and durability of PAFCs installed at users' sites. These activities have been expected to contribute to realizing economically viable systems and enhance market introduction. The superlative advantages of fuel cells, particularly their environment-friendly qualities, should be best taken advantage of at an appropriate time. In

  6. American National Standard: for facilities and medical care for on-site nuclear-power-plant radiological emergencies

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This standard provides guidance for first aid during an emergency and for initial medical care of those persons on-site who are overexposed to penetrating radiation (irradiated). It also provides guidance for medical care of persons contaminated with radioactive material or radionuclides who may also be irradiated or injured as a result of an accident at a nuclear power plant. It provides recommendations for facilities, supplies, equipment, and the extent of care both on-site where first aid and initial care may be provided and off-site at a local hospital where further medical and surgical care may be provided. This initial care continues until either the patient is released or admitted, or referred to another, possibly distant, medical center for definitive care. Recommendations are also provided for the transportation of patients and the training of personnel. Recommendations for specialized care are considered to be beyond the scope of this standard on emergency medical care; however, since emergency and specialized care are related, a brief discussion of specialized care is provided in the Appendix

  7. Recommended criteria for the evaluation of on-site nuclear power plant emergency plans, volume II: criteria

    International Nuclear Information System (INIS)

    1997-01-01

    A critical review of existing Canadian and international nuclear power plant (NPP) emergency plans, evaluation criteria, and approaches has been conducted to provide AECB staff with information which can be used to assess the adequacy of NPP on-site emergency response plans. The results of this work are published in two volumes. Volume I, Basis Document, provides the reasons why certain requirements are in place. It also gives comprehensive references to various standards.Volume II, Criteria, contains the criteria which relate to on-site actions and their integration with control room activities and the roles of off-site responsible organizations. The recommended criteria provide information on what is required, and not on how to accomplish the requirements. The licensees are given the latitude to decide on the methods and processes needed to meet the requirements. The documents do not address NPP off-site plans and response capability, or the control room emergency operating procedures and response capability. This report contains only Volume II: Criteria. 55 refs., 2 tabs., 1 fig

  8. Hinkley Point 'C' power station public inquiry: proof of evidence on on-site radioactive waste management and decommissioning

    International Nuclear Information System (INIS)

    Passant, F.H.

    1988-09-01

    A public inquiry has been set up to examine the planning application made by the Central Electricity Generating Board (CEGB) for the construction of a 1200 MW Pressurized Water Reactor power station at Hinkley Point (Hinkley Point ''C'') in the United Kingdom. The CEGB evidence to the Inquiry presented here provides information on the on-site management of solid, liquid and gaseous radioactive wastes both during station operation and during decommissioning. Estimates are given of current and projected future discharges of liquid and gaseous wastes from the site and packaging and transport arrangements for solid radioactive wastes are described. The framework of waste management policy, disposal strategy and legislation in the United Kingdom which will determine procedure at Hinkley Point ''C'' is given. (UK)

  9. Maximum power output and load matching of a phosphoric acid fuel cell-thermoelectric generator hybrid system

    Science.gov (United States)

    Chen, Xiaohang; Wang, Yuan; Cai, Ling; Zhou, Yinghui

    2015-10-01

    Based on the current models of phosphoric acid fuel cells (PAFCs) and thermoelectric generators (TGs), a new hybrid system is proposed, in which the effects of multi-irreversibilities resulting from the activation, concentration, and ohmic overpotentials in the PAFC, Joule heat and heat leak in the TG, finite-rate heat transfer between the TG and the heat reservoirs, and heat leak from the PAFC to the environment are taken into account. Expressions for the power output and efficiency of the PAFC, TG, and hybrid system are analytically derived and directly used to discuss the performance characteristics of the hybrid system. The optimal relationship between the electric currents in the PAFC and TG is obtained. The maximum power output is numerically calculated. It is found that the maximum power output density of the hybrid system will increase about 150 Wm-2, compared with that of a single PAFC. The problem how to optimally match the load resistances of two subsystems is discussed. Some significant results for practical hybrid systems are obtained.

  10. Development of an on-site measurement method for residual stress in primary system piping of nuclear power plants

    International Nuclear Information System (INIS)

    Maekawa, Akira; Takahashi, Shigeru; Fujiwara, Masaharu

    2014-01-01

    In residual stress measurement for large-scale pipes and vessels in high radiation areas and highly contaminated areas of nuclear plants, it is difficult to bring the radioactivated pipes and vessels out of the areas as they are. If they can brought out, it is very burdensome to handle them for the measurement. Development of an on-site measurement method of residual stress which can be quickly applied and has sufficient measurement accuracy is desirable. In this study, a new method combining an electric discharge skim-cut method with a microscopic strain measurement method using markers was proposed to realize the on-site residual stress measurement on pipes in high radiation areas and highly contaminated areas. In the electric discharge skim-cut method, a boat-type sample is skimmed out of a pipe outer/inner surface using electric discharge machining and released residual stress is measured. The on-site measurement of residual stress by the method can be done using a small, portable electric discharge machine. In the microscopic strain measurement method using markers, the residual stress is estimated by microscopic measurement of the distance between markers after the stress release. The combination of both methods can evaluate the residual stress with the same accuracy as conventional methods offer and it can achieve reduction of radiation exposure in the measurement because the work is done simply and rapidly. In this study, the applicability of the electric discharge skim-cut method was investigated because the applicability of the microscopic strain measurement method using markers was confirmed previously. The experimental examination clarified the applicable conditions for the residual stress measurement with the same accuracy as the conventional methods. Furthermore, the electric discharge machining conditions using pure water as the machining liquid was found to eliminate the amount of liquid radioactive waste completely. (author)

  11. Evaluation of the electrode performance for PAFC by using acid absorption, acceleration and ac-impedance measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang-Soo; Song, Rak-Hyun; Choi, Byung-Woo [Korea Institute of Energy Research, Taejon (Korea, Republic of)] [and others

    1996-12-31

    In PAFC, the degradation on cathode electrode caused by carbon corrosion, platinum dissolution and growth is especially severe. An acceleration test is a good technique for evaluating the degradation of electrode performance, because it does not need long time. Coleman et al used thermal cycling and on-off cycling as an acceleration test. Song et al showed that hydrogen shortage decreased the electrode performance more rapidly than that of air shortage in gas shortage test. Honji et al reported that the rate of coarsening of Pt particle is rapid in open circuit potential and this is one of major causes on the performance degradation of electrode. The cathode performance has been studied by using acid absorption, acceleration and ac-impedance measurements as functions of the polytetrafluoroethylene (PTFE) contents and sintering temperatures of the electrode.

  12. Solar radiation - to - power generation models for one-axis tracking PV system with on-site measurements from Eskisehir, Turkey

    Science.gov (United States)

    Filik, Tansu; Başaran Filik, Ümmühan; Nezih Gerek, Ömer

    2017-11-01

    In this study, new analytic models are proposed for mapping on-site global solar radiation values to electrical power output values in solar photovoltaic (PV) panels. The model extraction is achieved by simultaneously recording solar radiation and generated power from fixed and tracking panels, each with capacity of 3 kW, in Eskisehir (Turkey) region. It is shown that the relation between the solar radiation and the corresponding electric power is not only nonlinear, but it also exhibits an interesting time-varying characteristic in the form of a hysteresis function. This observed radiation-to-power relation is, then, analytically modelled with three piece-wise function parts (corresponding to morning, noon and evening times), which is another novel contribution of this work. The model is determined for both fixed panels and panels with a tracking system. Especially the panel system with a dynamic tracker produces a harmonically richer (with higher values in general) characteristic, so higher order polynomial models are necessary for the construction of analytical solar radiation models. The presented models, characteristics of the hysteresis functions, and differences in the fixed versus solar-tracking panels are expected to provide valuable insight for further model based researches.

  13. Collaborative Russian-US work in nuclear material protection, control and accounting at the Institute of Physics and Power Engineering. 3: Emphasis on site-wide issues

    International Nuclear Information System (INIS)

    Kuzin, V.V.; Pshakin, G.M.; Belov, A.P.

    1997-07-01

    During 1997, collaborative Russian-US nuclear material protection, control, and accounting (MPC and A) tasks at the Institute of Physics and Power Engineering (IPPE) in Obninsk, Russia are focusing increasingly on site-wide issues, though there is continued work at several major facilities: the Fast Critical Facility, the Technological Laboratory for Fuel Fabrication, and the (new and existing) Central Storage Facility. The collaborative work is being done with US Department of Energy National Laboratories. IPPE's emphasis on site-wide issues has resulted in the formation of a separate division for MPC and A. This new division reports directly to the IPPE Chief Engineer. It is a separate scientific and engineering operating division responsible for coordination and harmonization of MPC and A at IPPE, as well as for audit, assessment and inspection. By virtue of the organizational independence of this new division, IPPE has significantly strengthened the role of MPC and A. Two specific site-wide accomplishments are the consolidation of nuclear material from many buildings to a smaller number, and, as a major part of this strategy, the construction of a nuclear island surrounding the Fast Critical Facility and the new Central Storage Facility. Most of IPPE's weapons-grade nuclear materials will be concentrated within the nuclear island. The paper summarizes the following technical elements: computerized accounting, bar coding, weight measurements, gamma-ray measurements, tamper indicating devices, procedures for physical inventory taking and material balance closure, and video monitoring systems for storage and critical assembly areas

  14. Ultra Efficient CHHP Using a High Temperature Fuel Cell to Provide On-Site Process Reducing Gas, Clean Power, and Heat

    Energy Technology Data Exchange (ETDEWEB)

    Jahnke, Fred C. [Fuelcell Energy, Inc., Danbury, CT (United States)

    2015-06-30

    FuelCell Energy and ACuPowder investigated and demonstrated the use of waste anode exhaust gas from a high temperature fuel cell for replacing the reducing gas in a metal processing furnace. Currently companies purchase high pressure or liquefied gases for the reducing gas which requires substantial energy in production, compression/liquefaction, and transportation, all of which is eliminated by on-site use of anode exhaust gas as reducing gas. We performed research on the impact of the gas composition on product quality and then demonstrated at FuelCell Energy’s manufacturing facility in Torrington, Connecticut. This demonstration project continues to operate even though the research program is completed as it provides substantial benefits to the manufacturing facility by supplying power, heat, and hydrogen.

  15. On-site A.C. electric power sources for 900 MWe French nuclear power reactors: reliability and importance for safety

    Energy Technology Data Exchange (ETDEWEB)

    Milhem, J. L.; Gros, G. [Commissariat a l' Energie Atomique, Institut de Protection et Surete Nucleaire, Departement d' Analyse de Surete, B.P. No. 6, 92260 Fontenay-aux-Roses (France)

    1986-02-15

    After presenting briefly the new provisions laid down by the Electricite de France to meet a total electrical power loss, the main elements of the probabilistic study concerning the corresponding risk described: reliability data of internal sources used, results of risk Improvement brought by the new measures, importance for Internal source before and after Implementation of the new measures. (authors)

  16. On-site A.C. electric power sources for 900 MWe french nuclear power reactors: reliability and importances for safety

    International Nuclear Information System (INIS)

    Milhem, J.L.; Gros, G.

    1985-10-01

    After presenting briefly the new provisions laid down by the Electricite de France to meet a total electrical power loss, the main elements of the probabilistic study concerning the corresponding risk are described: reliability data of internal sources used, results of risk improvement brought by the new measures, importance for internal source before and after implementation of the new measures

  17. Woking Park PAFC CHP monitoring. Phase 1: Planning, installation and commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Goulding, P S; Fry, M R

    2003-07-01

    This report covers the planning, installation and commissioning of the first commercially operated fuel cell cogeneration system in the UK. The involvement of Woking Borough Council, its approach to energy efficiency, and the Woking Park site are discussed, and details are given of the PC25/C 200kW fuel cell which is manufactured in the US by UTC Fuel Cells. A description of the Woking Park fuel cell combined heat and power application is presented, and the project economics, specification and tendering are examined. The route taken to planning approval is traced, and installation procedures are outlined. The testing of the phosphoric type PC25 fuel cell cogeneration unit is described, and expected cost and project timescales are noted.

  18. Planning of occupational dose reduction at BWR power plant by past dose record analysis combined with on-site workers' idea analysis

    International Nuclear Information System (INIS)

    Konno, T.; Taira, J.; Hayashida, T.; Suzuki, A.; Hayashi, K.; Kato, S.; Ishikawa, T.; Konno, T.; Hayashi, K.

    2011-01-01

    In order to establish a plan for occupational dose reduction at operating plants, outage inspection works that involve high-dose exposure were selected and a determination of the major causes of high-dose exposure made by plant-by-plant comparison of doses received during inspection works. The comparison was made to investigate the relationship between exposure and the volume of objects to be inspected, working time and man-hour of each work process and ambient dose rates at work areas. In parallel with this, an analysis has also been carried out on 400 data items in a questionnaire survey conducted on relevant individuals, including foremen, radiation safety personnel, on-site workers and plant designers regarding ideas for dose reduction methods. With combination of these two analyses, matters that require improvement will be highlighted, then modification of equipment or revision of work procedures necessary for occupational dose reduction will be planned by plant designers through review. (authors)

  19. 太阳能光伏电站场址选择问题的探讨%Discussion on Site Selection of Solar Photovoitaic Power Station

    Institute of Scientific and Technical Information of China (English)

    毛思禹; 许文年; 侯燕梅; 祝立群; 张成

    2011-01-01

    太阳能是环保、安全的可再生能源,伴随能源危机和环境污染问题的出现受到了越来越广泛的关注.基于太阳能发电的需求,全面认识太阳能光伏发电的原理和光伏发电系统的组成,把握影响光伏电站发电量的因素具有现实意义.结合云南省某光伏电站工程实例,探讨了太阳能光伏电站场址选择的相关技术问题,并对其进行了总结,为太阳能光伏发电场址选择提供借鉴.%As an environmental and safe renewable energy, solar energy attracts extensive attention along with the emergence of energy crisis and environmental pollution. Basing on the demand of solar power generation, it is practically significant to comprehensively understand the principle and system composition of solar photovoltaic power generation, and to grasp the factors affecting output of photovoltaic power station. Combining with an engineering example of photovoltaic power station in Yunnan province, the paper summarizes and probes into the related technical problems of the solar photovoltaic power station's site selection, so as to provide reference for the site selection of solar photovoltaic power generation.

  20. Present on Site

    DEFF Research Database (Denmark)

    Ingemann, Bruno

    Why are exhibitions and museums so important? What can they be used for? Who determines relevance in a transformative process? Transforming exhibitions is not just something you do, it is something that gets better the more you do it. This book looks at the intersection of the visitor or user, who...... gets personal and cultural meaning from their visit and the museum as it appears in the design of the exhibition. It examines on-site communication for intentional and hidden content and messages, and reveals possible relations to the visitor, his or her world and society in general. This investigation...... also focuses on the processes involved in interpretation and design and takes a closer look at the practices of exhibiting rather than the objects on display. The four main themes in the book are: • Constructions – The visitor at an exhibition • Questions – Experience and learning processes...

  1. Mobil laboratory for the evaluation on site of the power electric equipment, second generation; Laboratorio movil para la evaluacion en sitio del equipo electrico de potencia, segunda generacion

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo C, Jaime; Escorsa M, Oscar; Estrada G, Javier A; Iturbe F, Marlene; Robles P, Edgar [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2005-07-01

    To the interior of the Generation of Electrical Equipment (GEE) of the Instituto de Investigaciones Electricas, one of the main activities is the diagnosis of the electrical equipment in service. It is well known that the power equipment represents a strong investment that requires the guarantee that it has been manufactured, installed and operated satisfactorily. The life expectancy of these devices is of thirty years, however, many of them already have surpassed that expectation. The rehabilitation or substitution of the equipment implies new investments that are needed for an evaluation of the real condition of the equipment to carry out such rehabilitation. One of the tools necessary to carry out the diagnosis, is a movable laboratory that facilitates all the necessary tools to perform a meticulous analysis that would allow, the client, to make high cost decisions. The application of the movable laboratory is advisable from the inauguration of the equipment. The electrical mechanisms are factory tested in accordance with standardized protocols; it guarantees the fulfillment of the necessary requirements for a correct operation. Nevertheless, when taking them to the assembly site, these are subjected to a series of processes and mechanical stresses that could alter the equipment conditions and its integrity. [Spanish] Al interior de la Generacion de Equipos Electricos (GEE) del Instituto de Investigaciones Electricas, una de las principales actividades es el diagnostico del equipo electrico en servicio. Es bien sabido que los equipos de potencia representan una fuerte inversion que requiere la garantia de que se ha fabricado, instalado y operado satisfactoriamente. La esperanza de vida de estos dispositivos es de treinta anos, no obstante, muchos de ellos ya han superado esa expectativa. La rehabilitacion o sustitucion de equipos, implica nuevas inversiones que precisan un conocimiento del estado real del equipo para llevarla a cabo. Una de las herramientas

  2. Liability for on-site nuclear property damage

    International Nuclear Information System (INIS)

    Neems, H.J.

    2000-01-01

    Typically, liability for on-site property addressed in contracts between operator and its suppliers. Nuclear power plant operators ordinarily protect themselves against risk of nuclear damage to on-site property by insurance. Nuclear liability laws do not specifically address liability for nuclear damage to on-site property. Nuclear plant owners should address risk of damage to on-site property when developing risk management program

  3. CTBT on-site inspections

    Science.gov (United States)

    Zucca, J. J.

    2014-05-01

    On-site inspection (OSI) is a critical part of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The OSI verification regime provides for international inspectors to make a suite of measurements and observations on site at the location of an event of interest. The other critical component of the verification regime is the International Monitoring System (IMS), which is a globally distributed network of monitoring stations. The IMS along with technical monitoring data from CTBT member countries, as appropriate, will be used to trigger an OSI. After the decision is made to carry out an OSI, it is important for the inspectors to deploy to the field site rapidly to be able to detect short-lived phenomena such as the aftershocks that may be observable after an underground nuclear explosion. The inspectors will be on site from weeks to months and will be working with many tens of tons of equipment. Parts of the OSI regime will be tested in a field exercise in the country of Jordan late in 2014. The build-up of the OSI regime has been proceeding steadily since the CTBT was signed in 1996 and is on track to becoming a deterrent to someone considering conducting a nuclear explosion in violation of the Treaty.

  4. Training Artisans On-Site

    Directory of Open Access Journals (Sweden)

    Edoghogho Ogbeifun

    2011-09-01

    Full Text Available The decline in apprenticeship in both the public and private sectors, the increasing use of sub-contractors as well as the uncoordinated approach in the informal sector are contributing factors to the shortage of skilled artisans in the construction industry. Artisans training can be introduced and implemented through the adoption of progressive implementation of construction processes commencing work from areas requiring low skill demands to areas of high skill demand. The success of this principle hinges on the collaborative effort of the key project stakeholders. The client should be willing to absorb extra cost and delays in the project; the design and contract documentation should facilitate on-site training, and  the consultant actively guide the contractor and the construction processes to achieve the training objectives. The exploratory research method was adopted in this study and research revealed that this principle was used in a project in the UK and in the development of infrastructure in the tourism industry of South Africa .It is being recommended that the principle be adapted by the public sector for the development of small size infrastructures that can be repeated in many places. This will boost the quality and quantity of artisans, enhance employability, reduce rural urban migration and alleviate poverty.Keywords: Skilled artisans, on-site training, progressive construction processes, project stakeholders, contract documentation. 

  5. On-site emergency planning

    International Nuclear Information System (INIS)

    Kueffer, K.

    1981-01-01

    This lecture covers the Emergency Planning of the Operating Organization and does not describe the functions and responsibilities of the Regulatory Body and public authorities. The lecture is based on the Codes of Practice and Safety Guides of the International Atomic Energy Agency (IAEA) and arrangements as in use in the Swiss Nuclear Power Station Beznau. (orig.)

  6. On-site emergency planning

    International Nuclear Information System (INIS)

    Kueffer, K.

    1980-01-01

    This lecture covers the Emergency Planning of the Operating organization and is based on the Code of Practice and Safety Guides of the IAEA as well as on arrangements in use at the Swiss Nuclear Power Station Beznau and - outlines the basis and content of an emergency plan - describes the emergencies postulated for emergency planning purposes - describes the responsibilities, the organization and the procedures of the operating organization to cope with emergency situations and the liaison between the operating organization, the regulatory body and public authorities - describes the facilities and equipment which should be available to cope with emergency sitauations - describes the measures and actions to be taken when an emergency arises in order to correct abnormal plant conditions and to protect the persons on-and off-site - describes the aid to be given to affected personnel - describes the aspects relevant to maintaining the emergency plan and organization in operational readiness. (orig./RW)

  7. On-Site Field Services

    International Nuclear Information System (INIS)

    Rodriguez Aycart, M.; Bobo, E.; Pascual, L.; Merino, A.; Martinez Gozalo, I.; Ruiz, J. T.; Soto, M.; Vilanova, S.

    2013-01-01

    The Spanish nuclear industry has extensive experience in the development of services for nuclear power plants. The moratorium on new projects in the decade of the 1980s led these nuclear industry companies to find and enter new markets. The quality of their services, along with the long experience gained in the support of the Spanish plants, has enabled a significant number of companies to win relevant contracts in competition with leading corporation around the world. European countries are an important market. The first experiments to support the operation in Central and Eastern Europe are being extended with work in neighboring countries. Meanwhile, Latin America is a nearby market for reasons of language and historical proximity, which is also present in the industry. It emphasizes the participation of Spanish companies in projects in countries of the Asia-Pacific region. This article describes the experiences of four Spanish-owned companies and of the services division of Westinghouse in spain. (Author)

  8. Electrochemical Power Sources

    Indian Academy of Sciences (India)

    ) (iv) Solid oxide fuel cells (SOFCs) (v) Poly- ... The advantages of PAFCs are that the phosphoric acid is very .... (as water is the only reaction product), and a thin electrolyte layer. Polymer electrolytes have excellent oxygen solubility and.

  9. On site DNA barcoding by nanopore sequencing.

    Directory of Open Access Journals (Sweden)

    Michele Menegon

    Full Text Available Biodiversity research is becoming increasingly dependent on genomics, which allows the unprecedented digitization and understanding of the planet's biological heritage. The use of genetic markers i.e. DNA barcoding, has proved to be a powerful tool in species identification. However, full exploitation of this approach is hampered by the high sequencing costs and the absence of equipped facilities in biodiversity-rich countries. In the present work, we developed a portable sequencing laboratory based on the portable DNA sequencer from Oxford Nanopore Technologies, the MinION. Complementary laboratory equipment and reagents were selected to be used in remote and tough environmental conditions. The performance of the MinION sequencer and the portable laboratory was tested for DNA barcoding in a mimicking tropical environment, as well as in a remote rainforest of Tanzania lacking electricity. Despite the relatively high sequencing error-rate of the MinION, the development of a suitable pipeline for data analysis allowed the accurate identification of different species of vertebrates including amphibians, reptiles and mammals. In situ sequencing of a wild frog allowed us to rapidly identify the species captured, thus confirming that effective DNA barcoding in the field is possible. These results open new perspectives for real-time-on-site DNA sequencing thus potentially increasing opportunities for the understanding of biodiversity in areas lacking conventional laboratory facilities.

  10. Fuel cell programs in the United States for stationary power applications

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M.

    1996-04-01

    The Department of Energy (DOE), Office of Fossil Energy, is participating with the private sector in sponsoring the development of molten carbonate fuel cell (MCFC) and solid oxide fuel cell (SOFC) technologies for application in the utility, commercial and industrial sectors. Phosphoric acid fuel cell (PAFC) development was sponsored by the Office of Fossil Energy in previous years and is now being commercialized by the private sector. Private sector participants with the Department of Energy include the Electric Power Research Institute (EPRI), the Gas Research institute (GRI), electric and gas utilities, universities, manufacturing companies and their suppliers. through continued government and private sector support, fuel cell systems are emerging power generation technologies which are expected to have significant worldwide impacts. An industry with annual sales of over a billion dollars is envisioned early in the 21st century. PAFC power plants have begun to enter the marketplace and MCFC and SOFC power plants are expected to be ready to enter the marketplace in the late 1990s. In support of the efficient and effective use of our natural resources, the fuel cell program seeks to increase energy efficiency and economic effectiveness of power generation. This is to be accomplished through effectiveness of power generation. This is accomplished through the development and commercialization of cost-effective, efficient and environmentally desirable fuel cell systems which will operate on fossil fuels in multiple and end use sectors.

  11. The transfer function method for the evaluation of short-circuit tests and on-site diagnostics of power transformers; Die Uebertragungsfunktion als Methode zur Beurteilung der Stosskurzschlusspruefung und Vor-Ort-Isolationsdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.; Feser, K. [Stuttgart Univ. (Germany). Inst. fuer Energieuebertragung und Hochspannungstechnik; Leibfried, T. [Siemens AG, Nuernberg (Germany). Geschaeftsgebiet Leistungstransformatoren; Jaeggi, F. [Aare-Tessin AG fuer Elektrizitaet, Olten (Switzerland)

    1999-03-22

    A short circuit test according to IEC 76-5 was performed on a 125 MVA, 245 kV/53 kV power transformer from the Siemens factory in Nuremberg at the Kema high power laboratory (Arnhem, Netherlands) in March 1997. Thereby, the transfer function method was examined as an additional method for evaluating the short-circuit test. The visual inspection of the transformer after returning to the Nuremberg factory carried out by engineers from Atel and Siemens and representatives of Kema showed no changes of the core and coil assembly. At the Flumenthal substation a second transformer of the same type was installed. Before commissioning, the transfer functions of both transformers have been measured. These measurements provide essential information concerning the comparability of measurements from different transformers and are the basis for measurements to be carried out in the future. (orig.) [Deutsch] Im Maerz 1997 wurde ein 125-MVA-Leistungstranformator aus dem Siemens Transformatorenwerk Nuernberg im Hochleistungslabor der Kema, Arnheim einer Stosskurzschlusspruefung unterzogen. Dabei wurde die Analyse der Uebertragungsfunktion des Transformators als zusaetzliche Methode zur Beurteilung der Stosskurzschlusspruefung untersucht. Der Aktivteil wurde danach im Herstellerwerk begutachtet. Dabei ergaben sich keine Beanstandungen. Im Umspannwerk Flumenthal wurde ein zweiter baugleicher Transformator installiert. Vor der Inbetriebnahme wurden zusaetzliche Vergleichsmessungen an den zwei baugleichen Transformatoren durchgefuehrt. (orig.)

  12. DBE on site public relations tasks

    International Nuclear Information System (INIS)

    Krug, H.J.; Meyer, R.

    1998-01-01

    Full text: Thesis: There is no 'golden rule' for an immediate increase in acceptance of nuclear facility sites - this applies to nuclear power plants as well as waste management facilities. The German Company for the Construction and Operation of Repositories for Waste Products (DBE - entrusted on behalf of the Federal Government with the management of all three German waste repository sites (projects), Morsleben, Konrad, Gorleben - concentrates in the field of public relations work on the following: - caring for (and informing) visitors from home and abroad; - cooperation with local and regional authorities and their representatives, press, media, etc. including associate editing of the GORLEBEN-information leaflet which appears monthly or every second month in cooperation with the Federal Board for Radiation Protection (BfS), as well as press releases if required; - responding to inquiries and visit requests of press, radio and TV. Basic work: - early and comprehensive information of the public at the sites about progress of work and possible exceptional events with special involvement of local politicians and representatives as well as press agencies. Close contacts exist to the local paper and to a national paper; - municipal representatives and the media are regularly directly informed on site or sporadically at their own request; - special emphasis is placed on the spoken, explaining word, namely that communication and discussion are valued more highly than written material. Of course, transparencies, films and brochures are available to support the spoken word; - continual availability for discussion and information presentations e.g., also at weekends; - maintenance of casual contacts to opponents of the plant. In Gorleben - the site of further waste management facilities beside the exploration mine - there is close cooperation with representatives of the other important companies and institutions hence, visitors are generally pooled, i.e., the majority

  13. The feasibility of mobile computing for on-site inspection.

    Energy Technology Data Exchange (ETDEWEB)

    Horak, Karl Emanuel; DeLand, Sharon Marie; Blair, Dianna Sue

    2014-09-01

    With over 5 billion cellphones in a world of 7 billion inhabitants, mobile phones are the most quickly adopted consumer technology in the history of the world. Miniaturized, power-efficient sensors, especially video-capable cameras, are becoming extremely widespread, especially when one factors in wearable technology like Apples Pebble, GoPro video systems, Google Glass, and lifeloggers. Tablet computers are becoming more common, lighter weight, and power-efficient. In this report the authors explore recent developments in mobile computing and their potential application to on-site inspection for arms control verification and treaty compliance determination. We examine how such technology can effectively be applied to current and potential future inspection regimes. Use cases are given for both host-escort and inspection teams. The results of field trials and their implications for on-site inspections are discussed.

  14. SICOM: On-site inspection systems

    International Nuclear Information System (INIS)

    Serna, J.J.; Quecedo, M.; Fernandez, J.R.

    2002-01-01

    As the irradiation conditions become more demanding for the fuel than in the past, there is a need for surveillance programs to gather in-reactor operating experience. The data obtained in these programs can be used to assess the performance of current fuel designs and the improvements incorporated to the fuel assembly design, the performance of the advanced cladding alloys, etc. In these regards, valuable data is obtained from on-site fuel inspections. These on-site data comprise fuel assembly dimensional data such as length and distortion (tilt, twist and bow) and fuel rod data such as length and oxide thickness. These data have to be reliable and accurate to be useful thus, demanding a high precision inspection equipment. However, the inspection equipment has to be also robust and flexible enough to operate in the plant spent fuel pool and, sometimes, without interfering in the works carried out during a plant outage. To meet these requirements, during the past years ENUSA and TECNATOM have developed two on-site inspection systems. While the first system can perform most of the typical measurements in a stand-alone manner thus, without interfering with the critical path of the reload, the second one reduces the inspection time but requires using the plant capabilities. The paper describes both equipment for fuel on-site inspection, their characteristics and main features. (author)

  15. Requirements of on-site facilities

    International Nuclear Information System (INIS)

    Burchardt, H.

    1977-01-01

    1) Requirements of on-site facilities: a) brief description of supplying the site with electricity and water; communication facilities, b) necessary facilities for containment and pipeline installation, c) necessary facilities for storage, safety, accommodation of personnel, housing; workshops; 2) Site management: a) Organisation schedules for 'turn-key-jobs' and 'single commission', b) Duties of the supervisory staff. (orig.) [de

  16. Status of small reactor designs without on-site refuelling

    International Nuclear Information System (INIS)

    2007-01-01

    There is an ongoing interest in member states in the development and application of small and medium sized reactors (SMRs). In the near term, most new NPPs are likely to be evolutionary designs building on proven systems while incorporating technological advances and often the economics of scale, resulting from the reactor outputs of up to 1600 MW(e). For the longer term, the focus is on innovative designs aiming to provide increased benefits in the areas of safety and security, non-proliferation, waste management, resource utilization and economy, as well as to offer a variety of energy products and flexibility in design, siting and fuel cycle options. Many innovative designs are reactors within the small-to-medium size range, having an equivalent electric power less than 700 MW(e) or even less than 300 MW(e). A distinct trend in design and technology development, accounting for about half of the SMR concepts developed worldwide, is represented by small reactors without on-site refuelling. Such reactors, also known as battery-type reactors, could operate without reloading and shuffling of fuel in the core over long periods, from 5 to 25 years and beyond. Upon the advice and with the support of IAEA member states, within its Programme 1 'Nuclear Power, Fuel Cycle, and Nuclear Science', the IAEA provides a forum for the exchange of information by experts and policy makers from industrialized and developing countries on the technical, economic, environmental, and social aspects of SMRs development and implementation in the 21st century, and makes this information available to all interested Member States by producing status reports and other publications dedicated to advances in SMR technology. The objective of this report is to provide Member States, including those just considering the initiation of nuclear power programmes and those already having practical experience in nuclear power, with a balanced and objective information on important development trends and

  17. Radioactive waste on-site storage alternative

    International Nuclear Information System (INIS)

    Dufrane, K.H.

    1983-01-01

    The first, most frequently evaluated approach for the large producer is the construction of a relatively expensive storage building. However, with the likely possibility that at least one disposal site will remain available and the building never used, such expenditures are difficult to justify. A low cost, but effective alternative, is the use of ''On-Site Storage Containers'' (OSSC) when and if required. Radwaste is only stored in the OSSC if a disposal site is not available. A small number of OSSC's would be purchased initially just to assure immediate access to storage. Only in the unlikely event of total disposal sites closure would additional OSSC's have to be obtained and even this is cost effective. With two or three months of storage available on site, production lead time is sufficient for the delivery of additional units at a rate faster than the waste can be produced. The recommended OSSC design would be sized and shielding optimized to meet the needs of the waste generator. Normally, this would duplicate the shipping containers (casks or vans) currently in use. The reinforced concrete design presented is suitable for outside storage, contains a leakproof polyethylene liner and has remote sampling capability. Licensing would be under 10CFR50.59 for interim storage with long-term storage under 10CFR30 not an impossibility. Cost comparisons of this approach vs. building construction show that for a typical reactor plant installation, the OSSC offers direct savings even under the worst case assumption that no disposal sites are available and the time value of money is zero

  18. An updated assessment of the prospects for fuel cells in stationary power and CHP. An information paper

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, T.K. [Future Energy Solutions, Harwell (United Kingdom)

    2005-07-01

    This report presents updated conclusions of the Department of Trade and Industry's research and development programme to assess the commercial prospects for advanced fuel cells in stationary power and combined heat and power (CHP) systems. The programme has focussed on low temperature solid polymer fuel cells (SPFCs) for transport and combined heat and power (CHP)/distributed power and high temperature solid oxide fuel cells (SOFCs) for CHP/distributed power. As well as assessing the prospects for SPFCs and SOFCs in stationary power and CHP applications, the report examines those for molten carbonate fuel cells (MCFCs) and phosphoric acid fuel cells (PAFCs). The report provides an assessment of the status of technology development for these different types of fuel cells in terms of applications to stationary power and CHP, and offers estimates of market potential for SOFCs in CHP markets, SPFCs in CHP markets and SOFCs in distributed power generation markets. Both large SPFC and SOFC CHP systems require further development to deliver the necessary cost reductions in materials and manufacturing processes before pre-commercial sales can begin. The routes taken by different manufacturers and their choice of preferred technology are explained. A discussion of the prospects and barriers for fuel cell cars concludes that while cost reduction is a major barrier to the successful commercialisation of fuel cells, there are insufficient data available from operating fuel cells systems (other than PAFC) in stationary power and CHP applications to assess the economic attractiveness of fuel cells compared with existing systems. More field trials are required to confirm energy and environmental performance in such applications and to evaluate operational and economic performance under commercial operating conditions. Such field trials could also provide a focus for the required developments in fuel cells for stationary power/CHP systems.

  19. Power

    DEFF Research Database (Denmark)

    Elmholdt, Claus Westergård; Fogsgaard, Morten

    2016-01-01

    and creativity suggests that when managers give people the opportunity to gain power and explicate that there is reason to be more creative, people will show a boost in creative behaviour. Moreover, this process works best in unstable power hierarchies, which implies that power is treated as a negotiable....... It is thus a central point that power is not necessarily something that breaks down and represses. On the contrary, an explicit focus on the dynamics of power in relation to creativity can be productive for the organisation. Our main focus is to elaborate the implications of this for practice and theory...

  20. Advanced on-site conceptual simulator for Forsmark 3

    International Nuclear Information System (INIS)

    Johansson, G.; Sjoestrand, K.

    1984-01-01

    On-site conceptual simulators have been extensively used at Swedish nuclear power plants. Despite having access to identical replica simulators, both the Swedish State Power Board and the Swedish private power industry have ordered conceptual simulators during 1982. The motivation has been that a complete training programme requires access to both a replica and a conceptual simulator. The replica simulator is perfect for training in control room behaviour but less appropriate for ensuring deeper process understanding. On the other hand, the conceptual simulator is not well suited for getting the personnel acquainted with the control room but is perfect for extending their knowledge of the plant processes. In order to give a realistic description of these processes, the conceptual simulator model must be fairly advanced. The Forsmark 3 conceptual simulator simulates the entire primary system, including the details of the steam and feedwater systems. Considerable attention has also been devoted to the presentation of calculated variables. For example, all the variables in the data base (approx. 6600) can be presented on colour-graphic CRTs as functions of time. (author)

  1. On-site monitoring of plutonium workers

    International Nuclear Information System (INIS)

    Burns, P.A.; Richardson, C.K.; Paulka, S.

    1996-01-01

    Full text: As part of the Maralinga rehabilitation program it is necessary to implement a system of on-site monitoring for the workers in order to ensure that they do not exceed recommended dose limits. The main problem in the rehabilitation work is the inhalation of dusts which contain micron sized plutonium particles. Using the new ICRP lung model and available data derived from measurements on contaminated soils, the intake for a dose of 20 mSv was calculated to be 1200 Bq. Four methods are available for direct measurements on workers; nasal swabs, faecal analysis, urine analysis and lung monitoring. The first two techniques are sensitive but will give varying results depending of the time interval between exposure and sampling. They are also difficult to implement on a routine basis. For the second two techniques, the activity in the lungs and the activity excreted per day in the urine remain relatively constant for several years following an intake, making more accurate dose estimates possible. The ICRP lung model predicts deposition in the lung of the order of 5% of intake and urinary excretion models predict approximately 10 -5 of this will be excreted daily in the urine. Lung monitoring of workers will be performed routinely at Maralinga in a partly enclosed room constructed from 10cm of steel, using two 50 mm diameter germanium detectors shielded with lead collimators. The detectors will measure 241 Am, which has grown in following the decay of 241 Pu, and the minimum detectable activity will be 15 - 20 Bq depending on the chest thickness and chest wall thickness of the individual being measured. Urine will be collected routinely and selected samples will be measured. The minimum detectable activity will be 2001μBq of 239 Pu in a daily urine sample

  2. Decisions on sites by Laender parliaments

    International Nuclear Information System (INIS)

    1977-01-01

    The Vereinigung Deutscher Elektrizitaetswerke (VDEW, Association of German Electricity Utilities) proposes two independent steps in the licensing procedure for each nuclear power plant constuction project: one first phase in which to establish site guarantees, and one licensing phase for construction and operation of the power plant. The first phase should henceforth proceed with the active participation of the public involved within the framework of a plans approval procedure. The novel aspect would be the binding clarification in this procedure not only of the nuclear aspects of the case, as formerly, but of all public aspects relating to the site. The construction and operating permits, which would constitute phase two, could then be handled in the usual procedure without any need for urgency. (orig.) [de

  3. 75 FR 66795 - TTM Technologies, Including On-Site Leased Workers From Kelly Services, Aerotek, and an On-Site...

    Science.gov (United States)

    2010-10-29

    ... follows: ``All workers TTM Technologies, including on-site leased workers from Kelly Services and Aerotek... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-64,993] TTM Technologies, Including On-Site Leased Workers From Kelly Services, Aerotek, and an On-Site Leased Worker From Orbotech...

  4. On-site voltage measurement with capacitive sensors on high voltage systems

    NARCIS (Netherlands)

    Wu, L.; Wouters, P.A.A.F.; Heesch, van E.J.M.; Steennis, E.F.

    2011-01-01

    In Extra/High-Voltage (EHV/HV) power systems, over-voltages occur e.g. due to transients or resonances. At places where no conventional voltage measurement devices can be installed, on-site measurement of these occurrences requires preferably non intrusive sensors, which can be installed with little

  5. Explanation of procedure on site medical emergency response for nuclear accident

    International Nuclear Information System (INIS)

    Liu Yulong; Jiang Zhong

    2012-01-01

    National occupational health standard-Procedure on Site Medical Emergency Response for Nuclear Accident has been approved and issued by the Ministry of Health. This standard is formulated according to the Emergency Response Law of the People's Republic of China, Law of the People 's Republic of China on Prevention and Control of Occupational Diseases, Regulations on Emergency Measures for Nuclear Accidents at Nuclear Power Plants, and Health Emergency Plans for Nuclear and Radiological Accidents of Ministry of Health, supporting the use of On-site Medical Emergency Planning and Preparedness for Nuclear Accidents and Off-site Medical Emergency Planning and Preparedness for Nuclear Accidents. Nuclear accident on-site medical response procedure is a part of the on-site emergency plan. The standard specifies the basic content and requirements of the nuclear accident on-site medical emergency response procedures of nuclear facilities operating units to guide and regulate the work of nuclear accident on-site medical emergency response of nuclear facilities operating units. The criteria-related contents were interpreted in this article. (authors)

  6. Development of emergency response training program for on-site commanders (1)

    International Nuclear Information System (INIS)

    Hikono, Masaru; Matsui, Yuko; Kanayama, Masaki

    2017-01-01

    Since the Great East Japan Earthquake of 2011, there have been increasing calls for developing the leadership capabilities of managers who are in charge of command and control of the on-site emergency response center at nuclear power plants. Training programs to improve non-technical skills are being developed and introduced. The authors developed an active learning exercise that can be repeatedly performed on-site, targeting on-site commander teams in charge of the initial response in an emergency situation. The exercise forms the core element of a non-technical skills training curriculum. This paper outlines the developed exercise, evaluates the stress on the participants caused by the exercise, and identifies any issues before actually introducing it to a site. (author)

  7. On-site energy consumption at softwood sawmills in Montana

    Science.gov (United States)

    Dan Loeffler; Nathaniel Anderson; Todd A. Morgan; Colin B. Sorenson

    2016-01-01

    Total on-site energy requirements for wood product manufacturing are generally not well understood or publicly available, particularly at subregional scales, such as the state level. This article uses a mail survey of softwood sawmills in Montana to develop a profile of all on-site energy consumption. Energy use is delineated by fuel type on a production basis...

  8. 7 CFR 205.403 - On-site inspections.

    Science.gov (United States)

    2010-01-01

    ..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) ORGANIC FOODS PRODUCTION ACT PROVISIONS NATIONAL ORGANIC PROGRAM Certification § 205.403 On-site inspections. (a) On-site inspections. (1... site that produces or handles organic products and that is included in an operation for which...

  9. On-site and off-site activities

    International Nuclear Information System (INIS)

    Martin, H.D.

    1986-01-01

    Design principles for NPP training programs. Effects of NPP contracts. Effects of domestic industrial activities. The role of international bodies. Requirements for on-site training. Training abroad, technical, financial and social aspects. Training center on-site, an evaluation. (orig.)

  10. Application profile and requirements on fuel cell heat-and-power stations; Einsatzprofil und Anforderungen an Brennstoffzellen-HKW

    Energy Technology Data Exchange (ETDEWEB)

    Kruhl, J

    1999-12-31

    In centralized power supply systems, maximum electrical efficiency is required in order to achieve competitiveness with high-efficiency combined-cycle systems. Combined systems of high-temperature fuel cells (MCFC/SOFC) with integrated gas or steam turbine processes are a promising option. In decentralized power supply, low-temperature and medium-temperature fuel cells (PEMFC/PAFC) may be feasible as well provided that the temperature characteristic of the demand side permits the use of the heat generated. In view of the decreasing heat demand of classic cogeneration structures, costly district heating will in the long run be replaced by building-specific cogeneration solutions. In this field, high-efficiency fuel cell systems have advantages over small-scale cogeneration units. If power-specific investments are low, the new technology may be more favourable than separate supply systems with networks and heating boilers and, in consequence, may gain wider acceptance. (orig.) [Deutsch] In der zentralen Stromerzeugung erfordert der Wettbewerb mit hocheffizienten GuD-Anlagen die Maximierung des elektrischen Wirkungsgrades. Hierzu bieten sich Kombianlagen aus Hochtemperatur-Brennstoffzellen (MCFC/SOFC) mit integrierten Dampf- bzw. Gasturbinen-Prozessen an. Im dezentralen Versorgungsbereich bieten zusaetzlich Nieder- und Mitteltemperatur-Brennstoffzellen (PEMFC/PAFC) ein hohes Einsatzpotential, sofern die Temperaturcharakteristik des Bedarfs eine Nutzbarkeit der entstehenden Waerme zulaesst. Unter dem Aspekt des zukuenftig sinkenden Waermebedarfs klassischer KWK-Strukturen wird die kostenintensive Nahwaermeversorgung zunehmend durch gebaeudespezifische KWK-Loesungen verdraengt werden. In diesem Bereich bieten hocheffiziente Brennstoffzellen-Systeme deutliche Vorteile gegenueber motorischen Klein-BHKW. Werden hier geringe leistungsspezifische Investitionen erreicht, kann eine Wirtschaftlichkeit gegenueber der getrennten Versorgung durch Netz und Heizkessel gegeben sein

  11. International Symposium on Site Characterization for CO2Geological Storage

    Energy Technology Data Exchange (ETDEWEB)

    Tsang, Chin-Fu

    2006-02-23

    Several technological options have been proposed to stabilize atmospheric concentrations of CO{sub 2}. One proposed remedy is to separate and capture CO{sub 2} from fossil-fuel power plants and other stationary industrial sources and to inject the CO{sub 2} into deep subsurface formations for long-term storage and sequestration. Characterization of geologic formations for sequestration of large quantities of CO{sub 2} needs to be carefully considered to ensure that sites are suitable for long-term storage and that there will be no adverse impacts to human health or the environment. The Intergovernmental Panel on Climate Change (IPCC) Special Report on Carbon Dioxide Capture and Storage (Final Draft, October 2005) states that ''Site characterization, selection and performance prediction are crucial for successful geological storage. Before selecting a site, the geological setting must be characterized to determine if the overlying cap rock will provide an effective seal, if there is a sufficiently voluminous and permeable storage formation, and whether any abandoned or active wells will compromise the integrity of the seal. Moreover, the availability of good site characterization data is critical for the reliability of models''. This International Symposium on Site Characterization for CO{sub 2} Geological Storage (CO2SC) addresses the particular issue of site characterization and site selection related to the geologic storage of carbon dioxide. Presentations and discussions cover the various aspects associated with characterization and selection of potential CO{sub 2} storage sites, with emphasis on advances in process understanding, development of measurement methods, identification of key site features and parameters, site characterization strategies, and case studies.

  12. Managing the risks of on-site health centers.

    Science.gov (United States)

    Gorman, Kathleen M; Miller, Ross M

    2011-11-01

    This review sought to assess compliance concerns, determine risk management strategies, and identify opportunities for future research to contribute to employers' understanding of the laws and regulations that apply to on-site care. A comprehensive review of databases, professional organizations' websites, and journals resulted in 22 publications reporting on the consequences of noncompliance among on-site health centers accepted for inclusion. None of those studies reported a study design or quantifiable outcome data. Two noncompliance themes were repeated among the publications. First, direct penalties included fines, civil actions, loss of licensure, and, potentially, criminal charges. Second, noncompliance also resulted in indirect costs such as employee mistrust and lowered standards of care, which jeopardize on-site health centers' ability to demonstrate a return on investment. Further research with rigorous methodology is needed to inform employer decisions about on-site health services and associated risk management. Copyright 2011, SLACK Incorporated.

  13. On site clean up with a hazardous waste incinerator

    International Nuclear Information System (INIS)

    Cross, F.L. Jr.; Tessitore, J.L.

    1987-01-01

    The Army Corps of Engineers and the EPA have determined that on-site incineration for the detoxification of soils, sediments, and sludges is a viable, safe, and economic alternative. This paper discusses an approach to on-site incineration as a method of detoxification of soils/sediments contaminated with organic hazardous wastes. Specifically, this paper describes the procedures used to evaluate on-site incineration at a large Superfund site with extensive PCB contaminated soils and sediments. The paper includes the following: (1) a discussion of site waste quantities and properties, (2) a selection of an incineration technology with a resulting concept and design, (3) a discussion of incinerator permitting requirements, (4) discussion and rationale for an incinerator sub-scale testing approach, and (5) analysis of on-site incineration cost

  14. MOLCARE development towards MCFC commercial power plants based on 500 kW standard modules

    Energy Technology Data Exchange (ETDEWEB)

    Torazza, A; Dufour, A; Perfumo, A; Ricerche, A; Gegundez, J; Sanson, F; Moreno, A

    1998-07-01

    Fuel cells technologies for stationary applications are expected to play a remarkable role in the field of next decade energy production systems ranging from some hundreds kW to some MW. The interest in using fuel cells to produce electric energy comes from the advantages that fuel cells offer in terms of high efficiency, good behavior at base and partial load, very low emissions, modularity (easy adjustment of plant capacity to power-demand increase), and reduced time to be spent for plant erection. At least four types of fuel cells can be considered suitable for stationary applications. With reference to their electrolyte they can be classified as: Polymeric Electrolyte Membrane Fuel Cells (PEMFC), Phosphoric Acid Fuel Cells (PAFC), Molten Carbonate Fuel Cells (MCFC) and Solid Oxide Fuel Cells (SOFC). Each of them works at a temperature level that is depending on the type of electrolyte. From a general point of view all the fuel cell technologies present, at various extents, the above listed advantages. Nevertheless specific features of each fuel cell type suggest to identify a specific field of application for each type of solution, in order to stress the potential advantages of any technology and minimize its possible drawbacks. Anyway the different level of maturity for the various fuel cell technologies does not allow an homogeneous comparison of technical and economical key parameters. PAFCs, due to their present commercial availability and operation experience, are well outlined in terms of performance and costs; on the contrary with regard to the other technologies--PEMFC, MCFC and SOFC--which are still under development, their commercialization is expected within a period of 7 to 13 years according to single technology maturity level (MCFC level seems to be more ready), kind of application, competitors, environmental constraints, etc.

  15. Predicting on-site environmental impacts of municipal engineering works

    OpenAIRE

    Gangolells Solanellas, Marta; Casals Casanova, Miquel; Forcada Matheu, Núria; Macarulla Martí, Marcel

    2014-01-01

    The research findings fill a gap in the body of knowledge by presenting an effective way to evaluate the significance of on-site environmental impacts of municipal engineering works prior to the construction stage. First, 42 on-site environmental impacts of municipal engineering works were identified by means of a process-oriented approach. Then, 46 indicators and their corresponding significance limits were determined on the basis of a statistical analysis of 25 new-build and remodelling mun...

  16. On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System Development

    Energy Technology Data Exchange (ETDEWEB)

    Caffrey, Gus J. [Idaho National Laboratory, Idaho Falls, ID (United States); Egger, Ann E. [Idaho National Laboratory, Idaho Falls, ID (United States); Krebs, Kenneth M. [Idaho National Laboratory, Idaho Falls, ID (United States); Milbrath, B. D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jordan, D. V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Warren, G. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wilmer, N. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-01

    We have designed and tested hardware and software for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—Osiris—software filters the spectral data to display only radioisotopic information relevant to CTBT on-site inspections, e.g.,132I. A set of over 100 fission-product spectra was employed for Osiris testing. These spectra were measured, where possible, or generated by modeling. The synthetic test spectral compositions include non-nuclear-explosion scenarios, e.g., a severe nuclear reactor accident, and nuclear-explosion scenarios such as a vented underground nuclear test. Comparing its computer-based analyses to expert visual analyses of the test spectra, Osiris correctly identifies CTBT-relevant fission product isotopes at the 95% level or better.The Osiris gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC Transpec-100, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer was used successfully during the recent 2014 CTBT Integrated Field Exercise in Jordan. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. To date, software development has been the main focus of the Osiris project. In FY2016-17, we plan to modify the Osiris hardware, integrate the Osiris software and hardware, and conduct rigorous field tests to ensure that the Osiris system will function correctly during CTBT on-site inspections. The planned development will raise Osiris to technology readiness level TRL-8; transfer the Osiris technology to a commercial manufacturer, and demonstrate Osiris to potential CTBT on-site inspectors.

  17. On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System Development

    International Nuclear Information System (INIS)

    Caffrey, Gus J.; Egger, Ann E.; Krebs, Kenneth M.; Milbrath, B. D.; Jordan, D. V.; Warren, G. A.; Wilmer, N. G.

    2015-01-01

    We have designed and tested hardware and software for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy-Osiris-software filters the spectral data to display only radioisotopic information relevant to CTBT on-site inspections, e.g.,132I. A set of over 100 fission-product spectra was employed for Osiris testing. These spectra were measured, where possible, or generated by modeling. The synthetic test spectral compositions include non-nuclear-explosion scenarios, e.g., a severe nuclear reactor accident, and nuclear-explosion scenarios such as a vented underground nuclear test. Comparing its computer-based analyses to expert visual analyses of the test spectra, Osiris correctly identifies CTBT-relevant fission product isotopes at the 95% level or better.The Osiris gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC Transpec-100, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer was used successfully during the recent 2014 CTBT Integrated Field Exercise in Jordan. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. To date, software development has been the main focus of the Osiris project. In FY2016-17, we plan to modify the Osiris hardware, integrate the Osiris software and hardware, and conduct rigorous field tests to ensure that the Osiris system will function correctly during CTBT on-site inspections. The planned development will raise Osiris to technology readiness level TRL-8; transfer the Osiris technology to a commercial manufacturer, and demonstrate Osiris to potential CTBT on-site inspectors.

  18. Predicting on-site environmental impacts of municipal engineering works

    International Nuclear Information System (INIS)

    Gangolells, Marta; Casals, Miquel; Forcada, Núria; Macarulla, Marcel

    2014-01-01

    The research findings fill a gap in the body of knowledge by presenting an effective way to evaluate the significance of on-site environmental impacts of municipal engineering works prior to the construction stage. First, 42 on-site environmental impacts of municipal engineering works were identified by means of a process-oriented approach. Then, 46 indicators and their corresponding significance limits were determined on the basis of a statistical analysis of 25 new-build and remodelling municipal engineering projects. In order to ensure the objectivity of the assessment process, direct and indirect indicators were always based on quantitative data from the municipal engineering project documents. Finally, two case studies were analysed and found to illustrate the practical use of the proposed model. The model highlights the significant environmental impacts of a particular municipal engineering project prior to the construction stage. Consequently, preventive actions can be planned and implemented during on-site activities. The results of the model also allow a comparison of proposed municipal engineering projects and alternatives with respect to the overall on-site environmental impact and the absolute importance of a particular environmental aspect. These findings are useful within the framework of the environmental impact assessment process, as they help to improve the identification and evaluation of on-site environmental aspects of municipal engineering works. The findings may also be of use to construction companies that are willing to implement an environmental management system or simply wish to improve on-site environmental performance in municipal engineering projects. -- Highlights: • We present a model to predict the environmental impacts of municipal engineering works. • It highlights significant on-site environmental impacts prior to the construction stage. • Findings are useful within the environmental impact assessment process. • They also

  19. Predicting on-site environmental impacts of municipal engineering works

    Energy Technology Data Exchange (ETDEWEB)

    Gangolells, Marta, E-mail: marta.gangolells@upc.edu; Casals, Miquel, E-mail: miquel.casals@upc.edu; Forcada, Núria, E-mail: nuria.forcada@upc.edu; Macarulla, Marcel, E-mail: marcel.macarulla@upc.edu

    2014-01-15

    The research findings fill a gap in the body of knowledge by presenting an effective way to evaluate the significance of on-site environmental impacts of municipal engineering works prior to the construction stage. First, 42 on-site environmental impacts of municipal engineering works were identified by means of a process-oriented approach. Then, 46 indicators and their corresponding significance limits were determined on the basis of a statistical analysis of 25 new-build and remodelling municipal engineering projects. In order to ensure the objectivity of the assessment process, direct and indirect indicators were always based on quantitative data from the municipal engineering project documents. Finally, two case studies were analysed and found to illustrate the practical use of the proposed model. The model highlights the significant environmental impacts of a particular municipal engineering project prior to the construction stage. Consequently, preventive actions can be planned and implemented during on-site activities. The results of the model also allow a comparison of proposed municipal engineering projects and alternatives with respect to the overall on-site environmental impact and the absolute importance of a particular environmental aspect. These findings are useful within the framework of the environmental impact assessment process, as they help to improve the identification and evaluation of on-site environmental aspects of municipal engineering works. The findings may also be of use to construction companies that are willing to implement an environmental management system or simply wish to improve on-site environmental performance in municipal engineering projects. -- Highlights: • We present a model to predict the environmental impacts of municipal engineering works. • It highlights significant on-site environmental impacts prior to the construction stage. • Findings are useful within the environmental impact assessment process. • They also

  20. On-Site Renewable Energy and Green Buildings: A System-Level Analysis.

    Science.gov (United States)

    Al-Ghamdi, Sami G; Bilec, Melissa M

    2016-05-03

    Adopting a green building rating system (GBRSs) that strongly considers use of renewable energy can have important environmental consequences, particularly in developing countries. In this paper, we studied on-site renewable energy and GBRSs at the system level to explore potential benefits and challenges. While we have focused on GBRSs, the findings can offer additional insight for renewable incentives across sectors. An energy model was built for 25 sites to compute the potential solar and wind power production on-site and available within the building footprint and regional climate. A life-cycle approach and cost analysis were then completed to analyze the environmental and economic impacts. Environmental impacts of renewable energy varied dramatically between sites, in some cases, the environmental benefits were limited despite the significant economic burden of those renewable systems on-site and vice versa. Our recommendation for GBRSs, and broader policies and regulations, is to require buildings with higher environmental impacts to achieve higher levels of energy performance and on-site renewable energy utilization, instead of fixed percentages.

  1. The advancement of fuel cell systems and spin-off battery technology. [PAFC, MCFC, SOFC, AFC, PEMFC, Zn/MnO=2-battery, MnO sub 2 /H sub 2 -battery

    Energy Technology Data Exchange (ETDEWEB)

    Kordesch, K [Technische Univ., Graz (Austria). Inst. fuer Chemische Technologie Anorganischer Stoffe

    1990-09-01

    The possibly large influence of fuel cell technology on several energy conversion and environmental aspects of the future is discussed. Solar energy and other renewable energy sources must have electrochemical storage facilities. Nuclear power can be used efficiently to electrolize water. The replacement of combustion engines in vehicles by fuel cell systems operating on hydrogen is the only way of reducing the increase of CO{sub 2} in the atmosphere if the greenhouse effect is becoming a threat. The fuel cell projects related to the manned space vehicles can provide many important spin-off's for accumulator designs and battery technology. (orig.).

  2. On-site disposal as a decommissioning strategy

    International Nuclear Information System (INIS)

    1999-11-01

    On-site disposal is not a novel decommissioning strategy in the history of the nuclear industry. Several projects based on this strategy have been implemented. Moreover, a number of studies and proposals have explored variations within the strategy, ranging from in situ disposal of entire facilities or portions thereof to disposal within the site boundary of major components such as the reactor pressure vessel or steam generators. Regardless of these initiatives, and despite a significant potential for dose, radioactive waste and cost reduction, on-site disposal has often been disregarded as a viable decommissioning strategy, generally as the result of environmental and other public concerns. Little attention has been given to on-site disposal in previous IAEA publications in the field of decommissioning. The objective of this report is to establish an awareness of technical factors that may or may not favour the adoption of on-site disposal as a decommissioning strategy. In addition, this report presents an overview of relevant national experiences, studies and proposals. The expected end result is to show that, subject to safety and environmental protection assessment, on-site disposal can be a viable decommissioning option and should be taken into consideration in decision making

  3. On-Site Measurements for Voltage Unbalance Studies Associated with the AC Railway Operation

    DEFF Research Database (Denmark)

    Stamatopoulos, Athanasios; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    unbalance with regards to traction loads has been augmented since the decision to expand the electric railway. Towards this direction, and on the occasion of a newly built electrified line, voltage unbalance measurements were carried out and are presented in this paper. The information from the extracted......On-site measurements in Electrical Power Systems can provide valuable information about the performance of the network and also, can be of great assistance to the validation and assessment of simulation models developed for power system studies. Lately, the noticeable increase of non......-conventional types of loads, such as the AC railway, has raised concerns regarding the secure operation of power transmission networks. This renders the monitoring and reporting of various aspects of system’s power quality even more necessary. For the Danish transmission grid, in particular, the relevance of voltage...

  4. Analysis of a fuel cell on-site integrated energy system for a residential complex

    Science.gov (United States)

    Simons, S. N.; Maag, W. L.

    1979-01-01

    The energy use and costs of the on-site integrated energy system (OS/IES) which provides electric power from an on-site power plant and recovers heat that would normally be rejected to the environment is compared to a conventional system purchasing electricity from a utility and a phosphoric acid fuel cell powered system. The analysis showed that for a 500-unit apartment complex a fuel OS/IES would be about 10% more energy conservative in terms of total coal consumption than a diesel OS/IES system or a conventional system. The fuel cell OS/IES capital costs could be 30 to 55% greater than the diesel OS/IES capital costs for the same life cycle costs. The life cycle cost of a fuel cell OS/IES would be lower than that for a conventional system as long as the cost of electricity is greater than $0.05 to $0.065/kWh. An analysis of several parametric combinations of fuel cell power plant and state-of-art energy recovery systems and annual fuel requirement calculations for four locations were made. It was shown that OS/IES component choices are a major factor in fuel consumption, with the least efficient system using 25% more fuel than the most efficient. Central air conditioning and heat pumps result in minimum fuel consumption while individual air conditioning units increase it, and in general the fuel cell of highest electrical efficiency has the lowest fuel consumption.

  5. On-site storage of high level nuclear waste: attitudes and perceptions of local residents.

    Science.gov (United States)

    Bassett, G W; Jenkins-Smith, H C; Silva, C

    1996-06-01

    No public policy issue has been as difficult as high-level nuclear waste. Debates continue regarding Yucca Mountain as a disposal site, and-more generally-the appropriateness of geologic disposal and the need to act quickly. Previous research has focused on possible social, political, and economic consequences of a facility in Nevada. Impacts have been predicted to be potentially large and to emanate mainly from stigmatization of the region due to increased perceptions of risk. Analogous impacts from leaving waste at power plants have been either ignored or assumed to be negligible. This paper presents survey results on attitudes of residents in three counties where nuclear waste is currently stored. Topics include perceived risk, knowledge of nuclear waste and radiation, and impacts on jobs, tourism, and housing values from leaving waste on site. Results are similar to what has been reported for Nevada; the public is concerned about possible adverse effects from on-site storage of waste.

  6. Number of on-site personnel and their functions

    International Nuclear Information System (INIS)

    Recker, M.

    1986-01-01

    After the definition of the general tasks, the development of an organization chart for on-site personnel is shown, the number and qualifications are indicated relating to the specific jobs. The functions of the different people are explained in detail. (orig.)

  7. Local Area Artworks: Collaborative Art Interpretation On-Site

    DEFF Research Database (Denmark)

    Polli, Anna Maria; Korn, Matthias; Klokmose, Clemens Nylandsted

    2013-01-01

    In this paper we present Local Area Artworks, a system enabling collaborative art interpretation on-site deployed during an exhibition in a local art gallery. Through the system, we explore ways to re-connect people to the local place by making use of their personal mobile devices as interfaces...

  8. In-situ and on-site technologies; An overview

    Energy Technology Data Exchange (ETDEWEB)

    Freestone, F J [Technical Support Branch, ORD, RREL, U.S. EPA, Edison, New Jersey (US)

    1990-01-01

    A broad analysis of and perspective on the characteristics and measured performance of in-situ and on-site treatment technologies available for remediation of contaminated soils, groundwater and associated debris at hazardous waste sites. Included in the analysis is information from U.S. and European sources. Available data are appended from nine recently completed field demonstrations from the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) program. The most frequently applied technology areas appear to be on-site thermal treatment for organics, on-site and in-situ solidification/stabilization technologies for most inorganics and metals, traditional on-site water treatment techniques, and soil vapor extraction for volatile organic compounds. Rapidly developing areas include bioremediation technologies, and concentration technologies. Two of the weakest areas include materials handling for such situations as excavating buried drums and soils with volatiles safely, and performing physical and chemical site characterization using technology-sensitive parameters. An area worthy of international cooperatin is that of performing benchscale screening and treatability studies, including the specification of key parameters needing measurement, techniques for such measurement and for interpretation, storage and retrieval of resulting data. We are in the process of evaluating existing treatability study data on soils and debris, and will be installing that data onto an on-line information system available to the public world-wide. (AB) 10 refs.

  9. On-site underground background measurements for the KASKA reactor-neutrino experiment

    International Nuclear Information System (INIS)

    Furuta, H.; Sakuma, K.; Aoki, M.; Fukuda, Y.; Funaki, Y.; Hara, T.; Haruna, T.; Ishihara, N.; Katsumata, M.; Kawasaki, T.; Kuze, M.; Maeda, J.; Matsubara, T.; Matsumoto, T.; Miyata, H.; Nagasaka, Y.; Nakagawa, T.; Nakajima, N.; Nitta, K.; Sakai, K.; Sakamoto, Y.; Suekane, F.; Sumiyoshi, T.; Tabata, H.; Tamura, N.; Tsuchiya, Y.

    2006-01-01

    On-site underground background measurements were performed for the planned reactor-neutrino oscillation experiment KASKA at Kashiwazaki-Kariwa nuclear power station in Niigata, Japan. A small-diameter boring hole was excavated down to 70m underground level, and a detector unit for γ-ray and cosmic-muon measurements was placed at various depths to take data. The data were analyzed to obtain abundance of natural radioactive elements in the surrounding soil and rates of cosmic muons that penetrate the overburden. The results will be reflected in the design of the KASKA experiment

  10. On-Site or Off-Site Renewable Energy Supply Options?

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Heiselberg, Per; Jensen, Rasmus Lund

    2012-01-01

    The concept of a Net Zero Energy Building (Net ZEB) encompasses two options of supplying renewable energy, which can offset energy use of a building, in particular on-site or off-site renewable energy supply. Currently, the on-site options are much more popular than the off-site; however, taking...... into consideration the limited area of roof and/or façade, primarily in the dense city areas, the Danish weather conditions, the growing interest and number of wind turbine co-ops, the off-site renewable energy supply options could become a meaningful solution for reaching ‘zero’ energy goal in the Danish context...... five technologies, i.e., two on-site options: (1) photovoltaic, (2) micro combined heat and power, and three off-site options: (1) off-site windmill, (2) share of a windmill farm and (3) purchase of green energy from the 100% renewable utility grid. The results indicate that in case of the on...

  11. The development of an on-site container

    International Nuclear Information System (INIS)

    Glass, R.E.; McAllaster, M.E.; Jones, P.L.; McKinney, A.L.

    1992-01-01

    Sandia National Laboratories (SNL) has developed a package for the on-site transport of chemical munitions for the US Army. This package was designed to prevent the release of lethal quantities of chemical agents during transportation of munitions to the demilitarization facilities on-site. The packaging prevents auto-ignition of the munitions by limiting the thermal and structural assault on the munitions during an accident. This package, with some modifications to account for contents, may be suitable for the on-site transport of mixed wastes at United States Department of Energy facilities. This paper discusses the design and verification testing of the package. The safety criteria for the package were modeled after the International Atomic Energy Agency (IAEA) hypothetical accident sequence and modified to take credit for operational controls. The modified accident sequence consisted of drop, puncture, and thermal events. The post-accident leak rate was established to prevent harm to an exposed worker. The packaging has a mass of 8600 kg and can accommodate up to 3600 kg of contents. The interior of the package is 188 cm in diameter and 232 cm long. Two sample ports can be used to sample the interior of the package prior to opening the closure and an o-ring test port can be used to determine the leak rates prior to and after transport

  12. Continuous feed, on-site composting of kitchen garbage.

    Science.gov (United States)

    Hwang, Eung-Ju; Shin, Hang-Sik; Tay, Joo-Hwa

    2002-04-01

    Kitchen garbage generated at a school cafeteria was treated and stabilised in a controlled on-site composting unit for volume reduction and on-site utilisation of processed garbage. The on-site composter was fed with the garbage on a daily basis during the two-months experimental period. Compost was not removed from the unit but was entirely reused as a bulking agent in order to minimise the need for additional bulking agent and compost handling. Performance of the composter tinder this condition was investigated. Most of the easily degradable organic matter (EDM) in the garbage was biodegraded rapidly, and the final product had a low content of EDM. Lipids, total sugar, and hemi-cellulose were degraded 96%, 81%, and 66% respectively. Free air space (FAS) was higher than 0.5 all the time, so accumulation of dry matter in the unit was not significant in reducing reaction efficiency. Other reaction parameters such as pH and MC were kept within a suitable range; however, it was advisable to maintain MC at over 46%. As a result, this method of operation was able to stabilise the garbage with low sawdust demand and little compost production.

  13. A method for the rapid on-site assessment of handleability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, D.W.; Atkin, B.P. [University of Nottingham, Nottingham (United Kingdom). School of Chemical, Environmental and Mining Engineering

    2000-07-01

    The handleability monitor has been specifically designed to provide a simple, rapid and on-site assessment of the whole or part consignment of a coal blend in its 'as-prepared' or 'as-received' condition. Evaluation has been carried out at a number of user's coal-handling plants, on both metallurgical and power station coals from a variety of sources world-wide (Australia, South Africa, United Kingdom and USA). The results are used to predict which coals could routinely pass through handling plant at line capacity, without causing blockage or decay, and have also been correlated with the operator's perception of the coal's handling characteristics and problems caused (blockages in chutes, hoppers, etc.) on the coal handling plant. Monitors were located at a coal fired power station and at a coal handling plant at an iron and steel works. 16 refs., 9 figs.

  14. On-site worker-risk calculations using MACCS

    International Nuclear Information System (INIS)

    Peterson, V.L.

    1993-01-01

    We have revised the latest version of MACCS for use with the calculation of doses and health risks to on-site workers for postulated accidents at the Rocky Flats Plant (RFP) in Colorado. The modifications fall into two areas: (1) an improved estimate of shielding offered by buildings to workers that remain indoors; and, (2) an improved treatment of building-wake effects, which affects both indoor and outdoor workers. Because the postulated accident can be anywhere on plant site, user-friendly software has been developed to create those portions of the (revised) MACCS input data files that are specific to the accident site

  15. Design Status and Applications of Small reactors without On-site Refuelling

    International Nuclear Information System (INIS)

    Kuznetsov, V.

    2006-01-01

    Small reactors without on-site refuelling are the reactors that can operate without reloading and shuffling of fuel for a reasonably long period, consistent with plant economy and considerations of energy security, with no fresh or spent fuel being stored at a site during reactor operation. Such reactors could simplify the implementation of safeguards and provide certain guarantees of sovereignty to those countries that would prefer to lease fuel from a foreign vendor or, perhaps, an international fuel cycle centre. About 30 concepts of such reactors are being analyzed or developed in 6 IAEA Member States. They cover all principle reactor lines: water cooled, fast gas cooled, sodium cooled, lead or lead bismuth cooled and molten salt cooled reactors. An increased refuelling interval could be achieved with reduced core power density, burnable absorbers, or high conversion ratio. The design goals for small reactors without on-site refuelling, inter alia, include: difficult unauthorized access to fuel; design provisions to facilitate the implementation of safeguards; capability to survive all postulated accident scenarios without requiring emergency response in the public domain; economic competitiveness for anticipated market conditions and applications; the capability to achieve higher manufacturing quality through factory mass production, design standardization and common basis for design certification; and a flexibility in siting and applications. Such reactors are often considered in conjunction with fuel or NPP leasing Small reactors without on-site refuelling have many common technology development issues related to the provision of lifetime core operation, economic competitiveness, high level of safety and proliferation resistance. Reestablishment of a practice of licensing by test and establishment of legal provisions and the insurance scheme for a transit of fuel loads or factory fabricated reactors through the territory of a third country are mentioned as

  16. Testing the applicability of rapid on-site enzymatic activity detection for surface water monitoring

    Science.gov (United States)

    Stadler, Philipp; Vogl, Wolfgang; Juri, Koschelnik; Markus, Epp; Maximilian, Lackner; Markus, Oismüller; Monika, Kumpan; Peter, Strauss; Regina, Sommer; Gabriela, Ryzinska-Paier; Farnleitner Andreas, H.; Matthias, Zessner

    2015-04-01

    bacteria. Therefore the applicability of on-site enzymatic activity determination as a direct surrogate or proxy parameter for microbiological standard assays and quantification of fecal indicator bacteria (FIB) concentration could not be approved and further research in this field is necessary. Presently we conclude that rapid on-site detection of enzymatic activity is applicable for surface water monitoring and that it constitutes a complementary on-site monitoring parameter with high potential. Selection of the type of measured enzymatic activities has to be done on a catchment-specific basis and further work is needed to learn more about its detailed information characteristics in different habitats. The accomplishment of this method detecting continuous data of enzymatic activity in high temporal resolution caused by a target bacterial member is on the way of becoming a powerful tool for water quality monitoring, health related water quality- and early warning requirements.

  17. The development of an on-site container

    International Nuclear Information System (INIS)

    Glass, R.E.; McAllaster, M.E.; Jones, P.L.; McKinney, A.L.

    1993-01-01

    This paper describes the results of the development of a packaging designed for on-site transportation of chemical munitions. The criteria for the package were patterned after the requirements for Type B packagings, but were modified to take credit for the operational controls that could be applied on-site. The design phase has been completed and a contract has been placed for fabrication of 165 units. In addition to the tests completed during the design phase, a complete sequence of verification tests will be performed on the first fleet unit. This sequence will consist of: (1) a 22,700-kg load placed on the packaging for 24 hours, (2) the flat side free drop, (3) the center-of-gravity over closure joint puncture test, and (4) a 15-min all-engulfing JP-4 pool-fire test. At the completion of the test sequence, the package will be required to meet the less than 1 x 10 -1 std cc/s leak test. (J.P.N.)

  18. Laboratory and On-Site Tests for Rapid Runway Repair

    Directory of Open Access Journals (Sweden)

    Federico Leonelli

    2017-11-01

    Full Text Available The attention to rapid pavement repair has grown fast in recent decades: this topic is strategic for the airport management process for civil purposes and peacekeeping missions. This work presents the results of laboratory and on-site tests for rapid runway repair, in order to analyse and compare technical and mechanical performances of 12 different materials currently used in airport. The study focuses on site repairs, a technique adopted most frequently than repairs with modular elements. After describing mechanical and physical properties of the examined materials (2 bituminous emulsions, 5 cement mortars, 4 cold bituminous mixtures and 1 expanding resin, the study presents the results of carried out mechanical tests. The results demonstrate that the best performing material is a one-component fast setting and hardening cement mortar with graded aggregates. This material allows the runway reopening 6 h after the work. A cold bituminous mixture (bicomponent premixed cold asphalt with water as catalyst and the ordinary cement concrete allow the reopening to traffic after 18 h, but both ensure a lower service life (1000 coverages than the cement mortar (10,000 coverages. The obtained results include important information both laboratory level and field, and they could be used by airport management bodies and road agencies when scheduling and evaluating pavement repairs.

  19. Portable Infrared Laser Spectroscopy for On-site Mycotoxin Analysis

    Science.gov (United States)

    Sieger, Markus; Kos, Gregor; Sulyok, Michael; Godejohann, Matthias; Krska, Rudolf; Mizaikoff, Boris

    2017-03-01

    Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B1 affected peanuts at EU regulatory limits of 1250 μg kg-1 and 8 μg kg-1, respectively.

  20. 37Ar monitoring techniques and on-site inspection system

    International Nuclear Information System (INIS)

    Duan Rongliang; Chen Yinliang; Li Wei; Wang Hongxia; Hao Fanhua

    2001-01-01

    37 Ar is separated, purified and extracted from air sample with a low temperature gas-solid chromatographic purifying method, prepared into a radioactive measurement source and its radioactivity is measured with a proportional counter. Based on the monitoring result, a judgement can be made if an nuclear explosion event has happened recently in a spectabilis area. A series of element techniques that are associated the monitoring of the trace element 37 Ar have been investigated and developed. Those techniques include leaked gas sampling, 37 Ar separation and purification, 37 Ar radioactivity measurement and the on-site inspection of 37 Ar. An advanced 37 Ar monitoring method has been developed, with which 200 liters of air can be treated in 2 hours with sensitivity of 0.01 Bq/L for 37 Ar radioactivity measurement. A practical 37 Ar On-site Inspection system has been developed. This research work may provide technical and equipment support for the verification protection, verification supervision and CTBT verification

  1. The On-Site Analysis of the Cherenkov Telescope Array

    CERN Document Server

    Bulgarelli, Andrea; Zoli, Andrea; Aboudan, Alessio; Rodríguez-Vázquez, Juan José; De Cesare, Giovanni; De Rosa, Adriano; Maier, Gernot; Lyard, Etienne; Bastieri, Denis; Lombardi, Saverio; Tosti, Gino; Bergamaschi, Sonia; Beneventano, Domenico; Lamanna, Giovanni; Jacquemier, Jean; Kosack, Karl; Antonelli, Lucio Angelo; Boisson, Catherine; Borkowski, Jerzy; Buson, Sara; Carosi, Alessandro; Conforti, Vito; Colomé, Pep; Reyes, Raquel de los; Dumm, Jon; Evans, Phil; Fortson, Lucy; Fuessling, Matthias; Gotz, Diego; Graciani, Ricardo; Gianotti, Fulvio; Grandi, Paola; Hinton, Jim; Humensky, Brian; Inoue, Susumu; Knödlseder, Jürgen; Flour, Thierry Le; Lindemann, Rico; Malaguti, Giuseppe; Markoff, Sera; Marisaldi, Martino; Neyroud, Nadine; Nicastro, Luciano; Ohm, Stefan; Osborne, Julian; Oya, Igor; Rodriguez, Jerome; Rosen, Simon; Ribo, Marc; Tacchini, Alessandro; Schüssler, Fabian; Stolarczyk, Thierry; Torresi, Eleonora; Testa, Vincenzo; Wegner, Peter

    2015-01-01

    The Cherenkov Telescope Array (CTA) observatory will be one of the largest ground-based very high-energy gamma-ray observatories. The On-Site Analysis will be the first CTA scientific analysis of data acquired from the array of telescopes, in both northern and southern sites. The On-Site Analysis will have two pipelines: the Level-A pipeline (also known as Real-Time Analysis, RTA) and the level-B one. The RTA performs data quality monitoring and must be able to issue automated alerts on variable and transient astrophysical sources within 30 seconds from the last acquired Cherenkov event that contributes to the alert, with a sensitivity not worse than the one achieved by the final pipeline by more than a factor of 3. The Level-B Analysis has a better sensitivity (not be worse than the final one by a factor of 2) and the results should be available within 10 hours from the acquisition of the data: for this reason this analysis could be performed at the end of an observation or next morning. The latency (in part...

  2. Enhancement of on-site emergency diesel generator reliability

    International Nuclear Information System (INIS)

    Boner, G.L.; Hanners, H.W.

    1979-01-01

    The University of Dayton Research Institute has concluded a program designed to provide NRC/DOR with technical assistance in evaluating the factors leading to improved reliability of on-site emergency diesel generator (DG) units. The program consisted of a comprehensive review of DG maintenance and operating experience and a comparative evaluation of the DG manufacturer's recommendations. This information, will enable the NRC to improve the basis on which it makes regulatory decisions. The primary goal of the program is to better identify the main problem areas which decrease the reliability of the DG units and make recommendations. The report has attained the program objectives by identifying and discussing the more significant problems and presenting the recommended corrective actions. The identified problems have been categorized into three groups as a function of their significance

  3. CTBTO tests its on-site inspection regime in Kazakhstan

    International Nuclear Information System (INIS)

    2003-07-01

    The former Soviet Union's nuclear test site at Semipalatinsk in the east of today's Kazakhstan was closed down after Kazakhstan became an independent State in 1991. This region in the Kazakh steppe is deserted and pockmarked by countless craters, remnants of over 450 nuclear explosions that were detonated there. In September 2008, the area will start brimming with activity. Scientists, diplomats and journalists will arrive from all over the world to witness an endeavour in the Kazakh steppe that is of great significance for the safety of our planet. The organization that monitors the comprehensive ban on nuclear testing will conduct a large scale exercise to test one of the key elements of its global alarm system - on-site inspections.

  4. Utilizing the fluidized bed to initiate water treatment on site

    International Nuclear Information System (INIS)

    Ahmadvand, H.; Germann, G.; Gandee, J.P.; Buehler, V.T.

    1995-01-01

    Escalating wastewater disposal costs coupled with enforcement of stricter regulations push industrial sites previously without water treatment to treat on site. These sites, inexperienced in water treatment, require a treatment technology that is easily installed, operated, and maintained. The aerobic granular activated carbon (GAC) fluidized bed incorporates biological and adsorptive technologies into a simple, cost-effective process capable of meeting strict effluent requirements. Two case studies at industrial sites illustrate the installation and operation of the fluidized bed and emphasize the ability to use the fluidized bed singularly or as an integral component of a treatment system capable of achieving treatment levels that allow surface discharge and reinjection. Attention is focused on BTEX (benzene, toluene, ethylbenzene, and xylenes)

  5. CASDAC system: On-Site Multiplexer user's guide

    International Nuclear Information System (INIS)

    Yamamoto, Yoichi; Koyama, Kinji

    1993-03-01

    The CASDAC (Containment and Surveillance Data Authenticated Communication) system has been developed by JAERI for nuclear safeguards and physical protection of nuclear material. This system is a remote monitoring system for continual verification of security and safeguards status of nuclear material. The CASDAC system consists of two subsystems, one of them is a Grand Command Center (GCC) subsystem and the other is a facility subsystem. This report describes the outline and usage of the On-Site Multiplexer (OSM), which controls all other equipments in a facility subsystem and communicates with the GCC. This work has been carried out in the framework of Japan Support Programme for Agency Safeguards (JASPAS) as a project, JA-1. (author)

  6. Innovative on-site treatment cuts frac flowback water costs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-11-15

    Water is an essential component of the drilling and hydraulic fracturing or fracking process and so the natural gas industry is a heavy user of water. Learning from other industries, gas producers are now employing mobile service providers with the latest integrated treatment systems (ITS) to clean flowback and produced water from fracturing operations at the wellhead. This paper presents a novel on-site treatment for frac water. ITS are pre-fabricated on moveable skids or a truck trailer with all the necessary controls, piping, valves, instrumentation, pumps, mixers and chemical injection modules. They remove oil and other hydrocarbons, suspended solids, and dissolved metals from the frac water using the tightly controlled chemistry, separation and filtration technology. This method can cut the average cost of treating produced water by 50%, simultaneously allowing drillers to maximize their efforts and manpower on generating oil and gas profits, rather than on water treatment.

  7. A risk evaluation model using on-site meteorological data

    International Nuclear Information System (INIS)

    Kang, C.S.

    1979-01-01

    A model is considered in order to evaluate the potential risk from a nuclear facility directly combining the on site meteorological data. The model is utilized to evaluate the environmental consequences from the routine releases during normal plant operation as well as following postulated accidental releases. The doses to individual and risks to the population-at-large are also analyzed in conjunction with design of rad-waste management and safety systems. It is observed that the conventional analysis, which is done in two separate unaffiliated phases of releases and atmospheric dispersion tends to result in unnecessary over-design of the systems because of high resultant doses calculated by multiplication of two extreme values. (author)

  8. Greenhouse gas emissions from on-site wastewater treatment systems

    Science.gov (United States)

    Somlai-Haase, Celia; Knappe, Jan; Gill, Laurence

    2016-04-01

    Nearly one third of the Irish population relies on decentralized domestic wastewater treatment systems which involve the discharge of effluent into the soil via a percolation area (drain field). In such systems, wastewater from single households is initially treated on-site either by a septic tank and an additional packaged secondary treatment unit, in which the influent organic matter is converted into carbon dioxide (CO2) and methane (CH4) by microbial mediated processes. The effluent from the tanks is released into the soil for further treatment in the unsaturated zone where additional CO2 and CH4 are emitted to the atmosphere as well as nitrous oxide (N2O) from the partial denitrification of nitrate. Hence, considering the large number of on-site systems in Ireland and internationally, these are potential significant sources of greenhouse gas (GHG) emissions, and yet have received almost no direct field measurement. Here we present the first attempt to quantify and qualify the production and emissions of GHGs from a septic tank system serving a single house in the County Westmeath, Ireland. We have sampled the water for dissolved CO2, CH4 and N2O and measured the gas flux from the water surface in the septic tank. We have also carried out long-term flux measurements of CO2 from the drain field, using an automated soil gas flux system (LI-8100A, Li-Cor®) covering a whole year semi-continuously. This has enabled the CO2 emissions from the unsaturated zone to be correlated against different meteorological parameters over an annual cycle. In addition, we have integrated an ultraportable GHG analyser (UGGA, Los Gatos Research Inc.) into the automated soil gas flux system to measure CH4 flux. Further, manual sampling has also provided a better understanding of N2O emissions from the septic tank system.

  9. A business case for on-site generation: The BD biosciences pharmingen project

    Energy Technology Data Exchange (ETDEWEB)

    Firestone, Ryan; Creighton, Charles; Bailey, Owen; Marnay, Chris; Stadler, Michael

    2003-09-01

    Deregulation is haltingly changing the United States electricity markets. The resulting uncertainty and/or rising energy costs can be hedged by generating electricity on-site and other benefits, such as use of otherwise wasted heat, can be captured. The Public Utility Regulatory Policy Act (PURPA) of 1978 first invited relatively small-scale generators ({ge} 1 MW) into the electricity market. The advent of efficient and reliable small scale and renewable equipment has spurred an industry that has, in recent years, made even smaller (business scale) electricity generation an economically viable option for some consumers. On-site energy capture and/or conversion, known as distributed energy resources (DER), offers consumers many benefits, such as economic savings and price predictability, improved reliability, control over power quality, and emissions reductions. Despite these benefits, DER adoption can be a daunting move to a customer accustomed to simply paying a monthly utility bill. San Diego is in many ways an attractive location for DER development: It has high electricity prices typical of California and a moderate climate i.e. energy loads are consistent throughout the year. Additionally, the price shock to San Diego Gas and Electric (SDG&E) customers during the summer of 2000 has interested many in alternatives to electricity price vulnerability. This report examines the business case for DER at the San Diego biotechnology supply company, BD Biosciences Pharmingen, which considered DER for a building with 200-300 kW base-load, much of which accommodates the refrigerators required to maintain chemicals. Because of the Mediterranean climate of the San Diego area and the high rate of air changes required due to on-site use of chemicals, modest space heating is required throughout the year. Employees work in the building during normal weekday business hours, and daily peak loads are typically about 500 kW.

  10. On-site emergency preparedness and response PLAN for EDF Nuclear Power Plants

    International Nuclear Information System (INIS)

    BOSSARD, J. L.

    1997-01-01

    Considering nuclear safety concepts applied to reactor design and preventive measures taken by EDF during operation, and although the probability of a nuclear accident, even minor, on a unit is very low, it still cannot be considered nil. Therefore, the operator must be prepared, if such an event should occur, by defining and implementing a 'crisis organisation' in cooperation with the Safety Authorities. The crisis organisation has been set up in order to master and control the accident, i.e. in order to prevent, in real time, the accident developing into a more serious situation and to limit the consequences regarding technical and radiological concerns. EDF crisis organisation is integrated into the current organisation at local level as well as at national level. In addition to the operation team in 'shifts', crisis organisation is based 'on-call' personnel available at home (local level) or within a restricted area (national level). This organisation includes Managers, Experts, Participants EDF (+FRAMATOME), each of the them working, in case of an emergency, in his field of skills

  11. Micro-grid for on-site wind-and-hydrogen powered generation

    Directory of Open Access Journals (Sweden)

    Suskis P.

    2014-02-01

    Full Text Available Rakstā piedāvātā mikrotīkla izpēte ir veikta ar mērķi izstrādāt autonomu, uz vēja un ūdeņraža enerģiju balstītu elektroapgādes sistēmu, kas varētu aizvietot tradicionālās fosilā kurināmā sistēmas, piemēram, mājsaimniecību dīzeļa ģeneratorus, gāzes mikroturbīnas u.c. Mikrotīkla elektroapgādes sistēmā vēja agregāta saražotā elektroenerģija tiek pārveidota atbilstoši standarta maiņsprieguma elektroapgādes parametriem un piegādāta slodzei. Pārpalikusī enerģija tiek pārveidota un uzkrāta ūdeņraža formā, izmantojot elektrolīzes iekārtu un kompozītmateriālu uzkrājēju. Ja pieejamā vēja enerģija nenosedz slodzes enerģijas patēriņu, elektroenerģijas padeves funkciju ar atbilstoša energoelektronikas pārveidotāja palīdzību pārņem ūdeņraža degvielas elements. Ja, savukārt, slodzei nav nepieciešama enerģija, no vēja saražoto enerģiju izmanto elektrolīzes iekārta un tā tiek uzkrāta ūdeņraža formā, atbilstoši uzkrājēja ietilpībai. Piedāvātajā mikrotīklā ir izmantota elektrolīzes iekārta ar netradicionāliem elektrodu pārklājumiem un barošanas bloku, kā arī zemspiediena kompozītmateriālu ūdeņraža uzkrājējs. Galvenie mikrotīkla elektriskās enerģijas pārveidošanas mezgli ir realizēti uz energoefektīvu energoelektronikas pārveidotāju bāzes. Ir izveidoti atsevišķo piedāvātās elektroapgādes sistēmas iekārtu prototipi un veiktas to eksperimantālās pārbaudes, gan atsevišķi, gan darbam kopējā sistēmā.

  12. New concepts for small power reactors without on-site refuelling for non-proliferation

    International Nuclear Information System (INIS)

    Brown, N.W.; Hasberger, J.A.

    2000-01-01

    The report discusses the preliminary requirements and a technical approach for developing small reactors and the rationale for selecting them. It then discusses the four nuclear system technologies and how they might proceed to meet the requirements. Brief discussions are provided on the approaches to stimulating the appropriate international and industrial participation necessary to finance development of a design with improved proliferation resistance that is useful to the developing countries. (author)

  13. On-site storage of high level nuclear waste: Attitudes and perceptions of local residents

    International Nuclear Information System (INIS)

    Bassett, G.W. Jr.; Jenkins-Smith, H.C.; Silva, C.

    1996-01-01

    No public policy issue has been as difficult as high-level nuclear waste. Debates continue regarding Yucca Mountain as a disposal site, and - more generally - the appropriateness of geologic disposal and the need to act quickly. Previous research has focused on possible social, political, and economic consequences of a facility in Nevada. Impacts have been predicted to be potentially large and to emanate mainly from stigmatization of the region due to increased perceptions of risk. Analogous impacts from leaving waste at power plants have been either ignored or assumed to be negligible. This paper presents survey results on attitudes of residents in three countries where nuclear waste is currently stored. Topics include perceived risk, knowledge of nuclear waste and radiation, and impacts on jobs, tourism, and housing values from leaving waste on site. Results are similar to what has been reported for Nevada; the public is concerned about possible adverse effects from on-site storage of waste. 24 refs., 7 figs., 5 tabs

  14. On-site waste storage assuring the success of on-site, low-level nuclear waste storage

    International Nuclear Information System (INIS)

    Preston, E.L.

    1986-01-01

    Waste management has reached paramount importance in recent years. The successful management of radioactive waste is a key ingredient in the successful operation of any nuclear facility. This paper discusses the options available for on-site storage of low-level radioactive waste and those options that have been selected by the Department of Energy facilities operated by Martin Marietta Energy Systems, Inc. in Oak Ridge, Tennessee. The focus of the paper is on quality assurance (QA) features of waste management activities such as accountability and retrievability of waste materials and waste packages, retrievability of data, waste containment, safety and environmental monitoring. Technical performance and careful documentation of that performance are goals which can be achieved only through the cooperation of numerous individuals from waste generating and waste managing organizations, engineering, QA, and environmental management

  15. Experiences in solving the challenges of on-site degree programs

    International Nuclear Information System (INIS)

    Christenson, J.M.; Eckart, L.E.

    1987-01-01

    The University of Cincinnati (UC) Nuclear Engineering Program Faculty has now had six years of experience in delivering on-site educational programs to nuclear power plant technical personnel. Programs of this type present a variety of challenges to the faculty, the management of the client utility and to the students who become involved in a particular program. This paper describes how each of these groups can identify and successfully solve these challenges. The solutions the authors describe are drawn from their own experiences which have been described in some detail elsewhere. Other solutions to those challenges are certainly possible. They make no claim for the particular ones they offer, beyond the fact that they have worked over a sustained period of time and that results they have produced have left all three parties mutually satisfied

  16. Impact of external events on site evaluation: a probabilistic approach

    International Nuclear Information System (INIS)

    Jaccarino, E.; Giuliani, P.; Zaffiro, C.

    1975-01-01

    A probabilistic method is proposed for definition of the reference external events of nuclear sites. The external events taken into account are earthquakes, floods and tornadoes. On the basis of the available historical data for each event it is possible to perform statistical analyses to determine the probability of occurrence on site of events of given characteristics. For earthquakes, the method of analysis takes into consideration both the annual frequency of seismic events in Italy and the probabilistic distribution of areas stricken by each event. For floods, the methods of analysis of hydrological data and the basic criteria for the determination of design events are discussed and the general lines of the hydraulic analysis of a nuclear site are shown. For tornadoes, the statistical analysis has been performed for the events which occurred in Italy during the last 40 years; these events have been classified according to an empirical intensity scale. The probability of each reference event should be a function of the potential radiological damage associated with the particular type of plant which must be installed on the site. Thus the reference event could be chosen such that for the whole of the national territory the risk for safety and environmental protection is the same. (author)

  17. ON-SITE SOLID PHRASE EXTRACTION AND LABORATORY ...

    Science.gov (United States)

    Fragrance materials, such as synthetic musks in aqueous samples, are normally analyzed by GC/MS in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. A I -L sample, however, usually provides too little analyte for full-scan data acquisition. An on-site extraction method for extracting synthetic musks from 60 L of wastewater effluent has been developed. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for various synthetic musk compounds. Quantification of these compounds was conveniently achieved from the full-scan data directly, without preparing SIM descriptors for each compound to acquire SIM data. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Quality. Located In the subtasks are the various research projects being performed in support of this Task and more in-depth coverage of each project. Briefly, each project's objective is stated below.Subtask 1: To integrate state-of-the-art technologies (polar organic chemical integrative samplers, advanced solid-phase extraction methodologies with liquid chromatography/electrospray/mass spectrometry) and apply them to studying the sources and fate of a select list of PPCPs. Application and improvement of analytical methodologies that can detect non-volatile, polar, water-sol

  18. On-site equipment and materials against CBRNE terrorism

    International Nuclear Information System (INIS)

    Yamamoto, Soichiro; Tokita, Kenichi

    2016-01-01

    There is no almighty field service equipment that can handle by itself all CBRNE (Chemical, Biological, Radiological, Nuclear, Explosive) terrorism. Since there is merit and demerit for each of equipment, operation methods and linkage of material/equipment based on detection principle are indispensable. This paper explained the principle and operation method of detection equipment, operation using multiple material/equipment, and system construction to facilitate cooperation with related ministries and agencies. There are six examples as typical material/equipment and detection principle for handling CBRNE as shown below: (1) ion mobility spectrometer, (2) infrared spectroscopy, (3) Raman scattering spectroscopy, (4) gas chromatographic mass spectrometry, (5) fluorescent reactive dye classification method, and (6) antigen antibody reaction method. This paper shows a flowchart that can measure within the duration of a respirator while wearing Level A protective clothing (about 15 to 20 min) by the combination of detector/analyzer based on these methods. The authors developed an information system that allows prompt information exchange between the on-site administrative agencies, research institutes, and other related organizations via network, in the case when substances etc. could not be specified in the above flowchart. (A.O.)

  19. An On-Site Presentation of Invisible Prehistoric Landscapes

    Directory of Open Access Journals (Sweden)

    Jiri Unger

    2017-03-01

    Full Text Available The rapid development of information technology has enabled the creation of entirely new presentation frameworks and this article will attempt to explore the subject of on-site presentation of archaeological sites. The most frequently used environment currently has been in the form of a variety of virtual museums that are accessible on the Internet; in essence these keep their visitors stuck in front of a PC monitor. One option that allows leaving the monitor and stepping directly out-of-doors into a virtual open-air museum is by means of applications for mobile phones. Terms such as 'virtual' or 'augmented reality' no longer represent a million light-years away science-fiction concepts, but rather a new tool for public archaeology and for the preservation of the archaeological heritage. This article presents several projects that have been implemented by the Archaeological Institute in Prague, who, by using mobile applications, built virtual open-air museums directly in the locations of archaeological excavations.

  20. ON-SITE SOLID-PHASE EXTRACTION AND LABORATORY ...

    Science.gov (United States)

    Fragrance materials such as synthetic musks in aqueous samples, are normally determined by gas chromatography/mass spectrometry in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. Full-scan mass spectra are required to verify that a target analyte has been found by comparison with the mass spectra of fragrance compounds in the NIST mass spectral library. A I -L sample usually provides insufficient analyte for full scan data acquisition. This paper describes an on-site extraction method developed at the U.S. Environmental Protection Agency (USEPA)- Las Vegas Nevada - for synthetic musks from 60 L of wastewater effluent. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for a wide array of synthetic musks. Quantification of these compounds was achieved from the full-scan data directly, without the need to acquire SIM data. The detection limits obtained with this method are an order of magnitude lower than those obtained from liquid-liquid and other solid phase extraction methods. This method is highly reproducible, and recoveries ranged from 80 to 97% in spiked sewage treatment plant effluent. The high rate of sorbent-sample mass transfer eliminated the need for a methanolic activation step, which reduced extraction time, labor, and solvent use, More samples could be extracted in the field at lower cost. After swnple extraction, the light- weight cartridges ar

  1. Development of on-site spent fuel transfer system designs

    International Nuclear Information System (INIS)

    Lambert, R.W.; Pennington, C.W.; Guerra, G.V.

    1993-01-01

    The Electric Power Research Institute (EPRI) of the United States has sponsored development of conceptual designs for accomplishing spent fuel transfer from spent fuel pools to casks and from one cask to another. Under an EPRI research contract, transnuclear has developed several concepts for spent fuel transfer systems. (J.P.N.)

  2. 75 FR 3250 - Glaxosmithkline, Including On-Site Temporary and Leased Workers From Kelly Services, Kelly...

    Science.gov (United States)

    2010-01-20

    ... subject firm. The workers are engaged in the production of penicillin-based antibiotics for humans and animals. The company reports that on-site leased workers from Dream Clean, Inc. were employed on-site at...

  3. Project VISION (Very Intensive Scientific Intercurricular On-Site Education

    Science.gov (United States)

    Roig, Gustavo A.

    1999-01-01

    Project VISION (Very Intensive Scientific Intercurricular On-Site Education) is a joint effort among NASA/John F. Kennedy Space Center, Florida International University, Universidad del Turabo, Miami-Dade County Public Schools and the Caguas/Gurabo Public Schools in Puerto Rico. The project's main mission is to institutionalize change among the elementary and middle school science and math teachers at participating schools so that their students receive continuously enriched instruction in the principles of science and math through the use of hands-on and minds-on experiments called learning modules. These leaming modules incorporate the national science and math education standards provided by the National Committee on Science Education Standards and Assessments and the National Council of Teachers of Mathematics, respectively. The use of learning modules that require hands-on and minds-on activities in a classroom setting garners great enthusiasm and motivation on the part of the target students for the understanding of the lesson's underlying math and science principles. With this enthusiasm and motivation, comes acceptance, attention, participation, discipline, acquiescence, and collaboration. Additionally, the use of hands-on activities may also require learning through a gamut of senses. Not only can the student use his/her eyes and ears during these activities, but most times, they can also use their senses of touch, smell, and taste, as well as intuition. Learning is, therefore, achieved using most or all the human senses. The combination of motivation/enthusiasm and the use of multiple senses creates an ideal environment conducive to leaming at a profound level.

  4. 75 FR 879 - National Semiconductor Corporation Arlington Manufacturing Site Including On-Site Leased Workers...

    Science.gov (United States)

    2010-01-06

    ... engaged in activities related to the production of integrated circuits. The company reports that on-site... Corporation Arlington Manufacturing Site Including On-Site Leased Workers From GCA, CMPA (Silverleaf), Custom..., applicable to workers of National Semiconductor Corporation, Arlington Manufacturing Site, including on-site...

  5. 75 FR 41895 - Whirlpool Corporation, Evansville Division, Including On-Site Leased Workers From Andrews...

    Science.gov (United States)

    2010-07-19

    ..., Evansville Division, Including On-Site Leased Workers From Andrews International, Inc., M.H. Equipment, and... 10321). The notice was amended on May 25, 2010 to include on-site leased workers from Andrews... workers of Whirlpool Corporation, Evansville Division, including on-site leased workers from Andrews...

  6. On-site and laboratory evaluations of soundscape quality in recreational urban spaces

    DEFF Research Database (Denmark)

    Bjerre, Lærke Cecilie; Larsen, Thea Mathilde; Sørensen, Anna Josefine

    2017-01-01

    on site. Moreover, the availability of the visual context in the listening experiment had no significant effect on the ratings. The participants were overall more positive toward natural sound sources on site. Conclusion: The full immersion in the on-site nonacoustic context may be important when...

  7. REPORT OF ON-SITE INSPECTION WORKSHOP-16

    Energy Technology Data Exchange (ETDEWEB)

    Sweeney, J J

    2009-07-07

    The central issue addressed by this workshop was the task of making the on-site inspection (OSI) part of the Comprehensive Nuclear-Test-Ban Treaty verification system operationally ready at entry into force of the Treaty. It is recognized, and this was emphasized by the 2008 OSI Integrated Field Exercise (IFE), that it is not possible to develop every part of the OSI regime simultaneously. Therefore, it is necessary to prioritize the approach to OSI readiness. The reviews of the IFE have pointed to many elements of OSI readiness that still need development. The objective of this workshop was to provide priorities for the path forward for Working Group B to consider. Several critical areas have been identified that are related to the development of OSI readiness: (1) Technology development: Priorities are radionuclide and noble gas sampling and analysis, visual observation, multispectral/infrared imaging methods, active seismic methods and the recognition of the importance of signatures. (2) Organizational development: Priorities are health and safety, the Operations Support Centre, the Equipment Storage and Maintenance Facility, information technology data flow and communications. (3) Resources: The expertise to develop key parts of the OSI regime is not available within the current OSI Division staff. To develop these aspects of the regime will require more staff or supplements to the staff with cost-free experts or other means. Aspects of the system that could benefit from more staff include radionuclide and noble gas detection methods, data flow and communications, visual observation, multispectral/infrared methods and health and safety. As the path forward, participants of this workshop recognized a need to optimize the development of OSI priorities. The outcome of this workshop is to suggest for consideration an operational approach to OSI readiness that utilizes results of an evaluation of the relative effectiveness of OSI elements versus their relative

  8. Flamanville 3 EPR, Safety Assessment and On-site Inspections

    International Nuclear Information System (INIS)

    Piedagnel, Corinne; Tarallo, Francois; Monnot, Bernard

    2011-01-01

    As a Technical Support Organisation of the French Safety Authority (ASN), the IRSN carries out the safety assessment of EPR project design and participates in the ASN inspections performed at the construction site and in factories. The design assessment consists in defining the safety functions which should be ensured by civil structures, evaluating the EPR Technical Code for Civil works (ETC-C) in which EdF has defined design criteria and construction rules, and carrying out a detailed assessment of a selection of safety-related structures. Those detailed assessments do not consist of a technical control but of an analysis whose objectives are to ensure that design and demonstrations are robust, in accordance with safety and regulatory rules. Most assessments led IRSN to ask EdF to provide additional justification sometimes involving significant modifications. In the light of those complementary justifications and modifications, IRSN concluded that assessments carried out on design studies were globally satisfactory. The participation of IRSN to the on-site inspections led by ASN is a part of the global control of the compliance of the reactor with its safety objectives. For that purpose IRSN has defined a methodology and an inspection program intended to ASN: based on safety functions associated with civil works (confinement and resistance to aggressions), the corresponding behaviour requirements are identified and linked to a list of main civil works elements. During the inspections, deviations to the project's technical specifications or to the rules of the art were pointed out by IRSN. Those deviations cover various items, such as concrete fabrication, concrete pouring methodology, lack of reinforcement in some structures, unadapted welding procedures of the containment leak-tight steel liner and unsatisfactory treatment of concreting joints. The analysis of those problems has revealed flaws in the organisation of the contractors teams together with an

  9. Perry Nuclear Plant's Plans for on-site storage

    International Nuclear Information System (INIS)

    Ratchen, J.T.

    1993-01-01

    Because of current radwaste disposal legislation and the eventual denial of access to the Barnwell, Richland, and Beatty burial sites, it was imperative for the Perry nuclear power plant to develop alternative means for handling its generated radioactive waste. The previous radwaste facilities at Perry were developed for processing, packaging, short-term storage, and shipment for burial. In order to meet the changing needs, new facilities have been constructed to handle the processing, packaging, and 5-yr interim storage of both dry active waste (DAW) and dewatered or solidified resin, filter media, etc

  10. Development of plant status display system for on-site educational training system

    International Nuclear Information System (INIS)

    Yoshimura, Seiichi; Fujimoto, Junzo; Okamoto, Hisatake; Tsunoda, Ryohei; Watanabe, Takao; Masuko, Jiro.

    1986-01-01

    The purpose of this system is to make easy the comprehension of the facility and dynamics of nuclear power plants. This report describes the tendency and future position of how the educational training system should be, and furthermore describes the experiment. Main results are as follows. 1. The present status and the future tendency of educational training system for nuclear power plant operators. CAI (Computer Assisted Instruction) system has following characteristics. (1) It is easy to introduce plant specific characteristics to the educational training. (2) It is easy to execute the detailed training for the compensation of the full-scale simulator. 2. Plant status display system for on-site educational training system. The fundamental function of the system is as follows. (1) It has 2 CRT displays and voice output devices. (2) It has easy manupulation type of man-machine interface. (3) It has the function for the evaluation of the training results. 3. The effectiveness of this system. The effectiveness evaluation test has been carried out by using this system actually. (1) This system has been proved to be essentially effective and some improvements for the future utilization has been pointed out. (2) It should be faster when the CRT displayes are changed, and it should have the explanation function when the plant transients are displayed. (author)

  11. Activities dedicated to FCPP commercialization at Toshiba

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Shin-ichi; Ozono, Jiro; Sato, Nobuaki [Toshiba Corp., Tokyo (Japan)

    1996-12-31

    The present line-up of fuel cell power plants (FCPPs) at Toshiba consists of 11MW FCPP for pressurized operation, 1000kW on-site FCPP and 200kW on-site FCPP. In these, an 11MW FCPP installed at Goi Power Station of Tokyo Electric Power Company (TEPCO) is providing valuable experience through more than 20,000 cumulative hours of operation. Also, a 1000kW on-site FCPP, which Toshiba manufactured under the joint program of NEDO and PAFC Technology Research Association, has cumulative operation of 7,500 hours. Toshiba, however, believes that the 200kW on-site FCPP is the leader in the commercialization of phosphoric acid FCPP. This paper therefore presents the development status of 200kW power plants and our strategic considerations for full commercialization of PC25 type 200kW FCPP.

  12. Industrial paramedics, out on site but not out of mind.

    Science.gov (United States)

    Acker, Joseph J; Johnston, Tania M; Lazarsfeld-Jensen, Ann

    2014-01-01

    (MOEMS). There is no single definition or comprehensive role description for industrial paramedic practice within the literature. Worldwide, there is little high-quality published evidence to adequately reflect all aspects of industrial paramedic practice. However, based on the literature available, this definition is offered: 'An industrial paramedic is an advanced clinical practitioner in paramedicine with an expanded scope of practice. The industrial paramedic provides emergency response, primary health care, chronic disease management, injury prevention, health promotion, medical referral, and repatriation coordination at remote mining sites, offshore installations, and other isolated industry settings. The industrial paramedic is resourceful, adaptable, and comfortable working independently. Industrial paramedics practice on site with limited resources, remotely located from tertiary care, and use telemedicine to consult with other health professionals as required. Industrial paramedics are experts at rapidly assessing, prioritising, and establishing control in their unpredictable workspace to reduce risks and create an environment conducive to quality patient care. The industrial paramedic preferably holds a specialised tertiary qualification and is committed to maintaining their clinical competency through continuing professional development.' Further research is required to validate, refute, or expand this proposed definition.

  13. Rapid on-site sensing aflatoxin B1 in food and feed via a chromatographic time-resolved fluoroimmunoassay.

    Directory of Open Access Journals (Sweden)

    Zhaowei Zhang

    Full Text Available Aflatoxin B1 poses grave threats to food and feed safety due to its strong carcinogenesis and toxicity, thus requiring ultrasensitive rapid on-site determination. Herein, a portable immunosensor based on chromatographic time-resolved fluoroimmunoassay was developed for sensitive and on-site determination of aflatoxin B1 in food and feed samples. Chromatographic time-resolved fluoroimmunoassay offered a magnified positive signal and low signal-to-noise ratio in time-resolved mode due to the absence of noise interference caused by excitation light sources. Compared with the immunosensing performance in previous studies, this platform demonstrated a wider dynamic range of 0.2-60 μg/kg, lower limit of detection from 0.06 to 0.12 µg/kg, and considerable recovery from 80.5% to 116.7% for different food and feed sample matrices. It was found to be little cross-reactivity with other aflatoxins (B2, G1, G2, and M1. In the case of determination of aflatoxin B1 in peanuts, corn, soy sauce, vegetable oil, and mouse feed, excellent agreement was found when compared with aflatoxin B1 determination via the conversational high-performance liquid chromatography method. The chromatographic time-resolved fluoroimmunoassay affords a powerful alternative for rapid on-site determination of aflatoxin B1 and holds a promise for food safety in consideration of practical food safety and environmental monitoring.

  14. Rapid on-site sensing aflatoxin B1 in food and feed via a chromatographic time-resolved fluoroimmunoassay.

    Science.gov (United States)

    Zhang, Zhaowei; Tang, Xiaoqian; Wang, Du; Zhang, Qi; Li, Peiwu; Ding, Xiaoxia

    2015-01-01

    Aflatoxin B1 poses grave threats to food and feed safety due to its strong carcinogenesis and toxicity, thus requiring ultrasensitive rapid on-site determination. Herein, a portable immunosensor based on chromatographic time-resolved fluoroimmunoassay was developed for sensitive and on-site determination of aflatoxin B1 in food and feed samples. Chromatographic time-resolved fluoroimmunoassay offered a magnified positive signal and low signal-to-noise ratio in time-resolved mode due to the absence of noise interference caused by excitation light sources. Compared with the immunosensing performance in previous studies, this platform demonstrated a wider dynamic range of 0.2-60 μg/kg, lower limit of detection from 0.06 to 0.12 µg/kg, and considerable recovery from 80.5% to 116.7% for different food and feed sample matrices. It was found to be little cross-reactivity with other aflatoxins (B2, G1, G2, and M1). In the case of determination of aflatoxin B1 in peanuts, corn, soy sauce, vegetable oil, and mouse feed, excellent agreement was found when compared with aflatoxin B1 determination via the conversational high-performance liquid chromatography method. The chromatographic time-resolved fluoroimmunoassay affords a powerful alternative for rapid on-site determination of aflatoxin B1 and holds a promise for food safety in consideration of practical food safety and environmental monitoring.

  15. 77 FR 13352 - Exxonmobil Chemical Company Films Business Division Including on-Site Leased Workers From...

    Science.gov (United States)

    2012-03-06

    ..., Take Care Corporation, Conestoga Rovers and Associates, Phillips Engineering, Rockwell Engineering, Excel Logistics, and American Food and Vending, Calhoun Spotting Service, and Job World working on-site...

  16. An accurate on-site calibration system for electronic voltage transformers using a standard capacitor

    Science.gov (United States)

    Hu, Chen; Chen, Mian-zhou; Li, Hong-bin; Zhang, Zhu; Jiao, Yang; Shao, Haiming

    2018-05-01

    Ordinarily electronic voltage transformers (EVTs) are calibrated off-line and the calibration procedure requires complex switching operations, which will influence the reliability of the power grid and induce large economic losses. To overcome this problem, this paper investigates a 110 kV on-site calibration system for EVTs, including a standard channel, a calibrated channel and a PC equipped with the LabView environment. The standard channel employs a standard capacitor and an analogue integrating circuit to reconstruct the primary voltage signal. Moreover, an adaptive full-phase discrete Fourier transform (DFT) algorithm is proposed to extract electrical parameters. The algorithm involves the process of extracting the frequency of the grid, adjusting the operation points, and calculating the results using DFT. In addition, an insulated automatic lifting device is designed to realize the live connection of the standard capacitor, which is driven by a wireless remote controller. A performance test of the capacitor verifies the accurateness of the standard capacitor. A system calibration test shows that the system ratio error is less than 0.04% and the phase error is below 2‧, which meets the requirement of the 0.2 accuracy class. Finally, the developed calibration system was used in a substation, and the field test data validates the availability of the system.

  17. Probabilistic Risk Assessment of Cask Drop Accident during On-site Spent Nuclear Fuel Transportation

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Jae Hyun; Christian, Robby; Momani, Belal Al; Kang, Hyun Gook [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    There are two ways to transfer the SNF from a site to other site, one is land transportation and the other is maritime transportation. Maritime transportation might be used because this way uses more safe route which is far from populated area. The whole transportation process can be divided in two parts: transferring the SNF between SNP and wharf in-Nuclear Power Plant (NPP) site by truck, and transferring the SNF from the wharf to the other wharf by ship. In this research, on-site SNF transportation between SNP and wharf was considered. Two kinds of single accident can occur during this type of SNF transportation, impact and fire, caused by internal events and external events. In this research, PRA of cask drop accident during onsite SNF transportation was done, risk to a person (mSv/person) from a case with specific conditions was calculated. In every 11 FEM simulation drop cases, FDR is 1 even the fuel assemblies are located inside of the cask. It is a quite larger value for all cases than the results with similar drop condition from the reports which covers the PRA on cask storage system. Because different from previous reports, subsequent impact was considered. Like in figure 8, accelerations which are used to calculate the FDR has extremely higher values in subsequent impact than the first impact for all SNF assemblies.

  18. Department of Energy's High Flux Beam Reactor (HFBR), September 15--19, 1980: An independent on-site safety review

    International Nuclear Information System (INIS)

    1981-02-01

    The intent of this on-site safety review was to make a broad management assessment of HFBR operations, rather than conduct a detailed in-depth audit. The result of the review should only be considered as having identified trends or indications. The Team's observations and recommendations for the most part are based upon licensed reactor facility practices used to meet industry standards. These standards form the basis for many of the comments in this report. The Team believes that a uniform minimum standard of performance should be achieved in the operation of DOE reactors. In order to assure that this is accomplished, clear standards are necessary. Consistent with the past AEC and ERDA policy, the team has used the standards of the commercial nuclear power industry. It is recognized that this approach is conservative in that the HFBR reactor has a significantly greater degree of inherent safety (low pressure, temperature, power, etc.) than a licensed reactor

  19. Electrokinetic remediation of plutonium-contaminated nuclear site wastes: Results from a pilot-scale on-site trial

    International Nuclear Information System (INIS)

    Agnew, Kieran; Cundy, Andrew B.; Hopkinson, Laurence; Croudace, Ian W.; Warwick, Phillip E.; Purdie, Philip

    2011-01-01

    This paper examines the field-scale application of a novel low-energy electrokinetic technique for the remediation of plutonium-contaminated nuclear site soils, using soil wastes from the Atomic Weapons Establishment (AWE) Aldermaston site, Berkshire, UK as a test medium. Soils and sediments with varying composition, contaminated with Pu through historical site operations, were electrokinetically treated at laboratory-scale with and without various soil pre-conditioning agents. Results from these bench-scale trials were used to inform a larger on-site remediation trial, using an adapted containment pack with battery power supply. 2.4 m 3 (ca. 4 tonnes) of Pu-contaminated soil was treated for 60 days at a power consumption of 33 kW h/m 3 , and then destructively sampled. Radiochemical data indicate mobilisation of Pu in the treated soil, and migration (probably as a negatively charged Pu-citrate complex) towards the anodic compartment of the treatment cell. Soil in the cathodic zone of the treatment unit was remediated to a level below free-release disposal thresholds (1.7 Bq/g, or <0.4 Bq/g above background activities). The data show the potential of this method as a low-cost, on-site tool for remediation of radioactively contaminated soils and wastes which can be operated remotely on working sites, with minimal disruption to site infrastructure or operations.

  20. 13 CFR 120.1051 - Frequency of on-site reviews and examinations.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Frequency of on-site reviews and examinations. 120.1051 Section 120.1051 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Risk-Based Lender Oversight Supervision § 120.1051 Frequency of on-site reviews and examinations...

  1. 13 CFR 120.1050 - On-site reviews and examinations.

    Science.gov (United States)

    2010-01-01

    ... losses); (3) Management quality (including internal controls, loan portfolio management, and asset... Risk-Based Lender Oversight Supervision § 120.1050 On-site reviews and examinations. (a) On-site... operations management; (3) Credit administration; and (4) Compliance with Loan Program Requirements. (b) On...

  2. 78 FR 28642 - Eastman Kodak Company, Electrographic Print Solutions, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-05-15

    ... Kodak Company, Electrographic Print Solutions, Including On-Site Leased Workers From Adecco and Datrose, Spencerport, New York; Eastman Kodak Company, IPS, Including On-Site Leased Workers From Adecco, Dayton, Ohio... Trade Adjustment Assistance (TAA) filed on behalf of Eastman Kodak Company, Electrographic Print...

  3. 78 FR 19530 - Eastman Kodak Company (GCG), Electrographic Print Solutions, Including On-Site Leased Workers...

    Science.gov (United States)

    2013-04-01

    ... Kodak Company (GCG), Electrographic Print Solutions, Including On-Site Leased Workers From Adecco and Datrose, Spencerport, New York; Eastman Kodak Company, IPS, Including On-Site Leased Workers From Adecco..., 2011, applicable to workers of Eastman Kodak Company (GCG), Electrographic Print Solutions, including...

  4. 78 FR 12358 - UBS Financial Services, Inc., Wealth Management Americas Operations, Including On-Site Leased...

    Science.gov (United States)

    2013-02-22

    ..., Inc., Wealth Management Americas Operations, Including On-Site Leased Workers From Leafstone... Services, Inc., Wealth Management Americas Operations (UBS), Weehawken, New Jersey. The workers are engaged... to include all leased workers on-site at UBS Financial Services, Inc., Wealth Management Americas...

  5. 78 FR 48468 - Delphi Corporation, Electronics and Safety Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-08-08

    ..., Electronics and Safety Division, Including On-Site Leased Workers From Securitas, Bartech, Flint Janitorial... Adjustment Assistance on May 20, 2013, applicable to workers of Delphi Corporation, Electronics and Safety... on- site at the Flint, Michigan location of Delphi Corporation, Electronics and Safety Division. The...

  6. 75 FR 62423 - Barnstead Thermolyne Corporation, a Subsidiary of Thermo Fisher Scientific, Including On-Site...

    Science.gov (United States)

    2010-10-08

    ... related to the production of scientific laboratory equipment. New information shows that workers leased... Corporation, a Subsidiary of Thermo Fisher Scientific, Including On-Site Leased Workers From Sedona Staffing... Scientific, including on- site leased workers from Sedona Staffing, Dubuque, Iowa. The notice was published...

  7. 75 FR 32221 - Whirlpool Corporation, Evansville Division, Including On-Site Leased Workers from Andrews...

    Science.gov (United States)

    2010-06-07

    ..., Evansville Division, Including On-Site Leased Workers from Andrews International, Inc., Evansville, IN... that workers leased from Andrews International, Inc. were employed on-site at the Evansville, Indiana... findings, the Department is amending this certification to include leased workers from Andrews...

  8. 77 FR 4368 - Abbott Laboratories, Diagnostics Division, Including On-Site Leased Workers From Manpower...

    Science.gov (United States)

    2012-01-27

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,201] Abbott Laboratories..., applicable to workers of Abbott Laboratories, Diagnostics Division, including on-site leased workers from... (clerical) were employed on-site at the Irving, Texas location of Abbott Laboratories, Diagnostics Division...

  9. 75 FR 28295 - Cummins Filtration, Including On-Site Leased Workers From Manpower and Spherion Staffing...

    Science.gov (United States)

    2010-05-20

    .... The Department has determined that workers from Spherion Staffing were sufficiently under the control..., Including On-Site Leased Workers From Manpower and Spherion Staffing, Including On-Site Workers From Hagemeyer North America, Lake Mills, IA; Amended Certification Regarding Eligibility To Apply for Worker...

  10. 76 FR 81986 - Honeywell International, Inc., Automation and Control Solutions Division, Including On-Site...

    Science.gov (United States)

    2011-12-29

    ..., Inc., Automation and Control Solutions Division, Including On-Site Leased Workers From Manpower...., Automation and Control Solutions Division. The Department has determined that these workers were sufficiently...., Automation and Control Solutions Division, including on-site leased workers from Manpower, Spherion...

  11. 76 FR 175 - Faurecia Emissions Control Technologies Including On-Site Leased Workers From Adecco Employment...

    Science.gov (United States)

    2011-01-03

    ... Technologies Including On-Site Leased Workers From Adecco Employment Servcies and Emcon Technologies, Troy, MI..., applicable to workers of Faurecia Emissions Control Technologies, Troy, Michigan, including on-site leased workers from Adecco Employment Services, Troy, Michigan. The Department's notice of determination was...

  12. The extent of on-site leakage in selected suburbs of Johannesburg ...

    African Journals Online (AJOL)

    This study investigated on-site leakage on 182 properties with relatively new municipal water meters in well-established suburbs of Johannesburg. A methodology was developed to estimate the on-site leakage rate from readings taken from these municipal water meters, which was then adjusted to account for metering ...

  13. Emergency power systems at nuclear power plants

    International Nuclear Information System (INIS)

    1982-01-01

    This Guide applies to nuclear power plants for which the total power supply comprises normal power supply (which is electric) and emergency power supply (which may be electric or a combination of electric and non-electric). In its present form the Guide provides general guidance for all types of emergency power systems (EPS) - electric and non-electric, and specific guidance (see Appendix A) on the design principles and the features of the emergency electric power system (EEPS). Future editions will include a second appendix giving specific guidance on non-electric power systems. Section 3 of this Safety Guide covers information on considerations that should be taken into account relative to the electric grid, the transmission lines, the on-site electrical supply system, and other alternative power sources, in order to provide high overall reliability of the power supply to the EPS. Since the nuclear power plant operator does not usually control off-site facilities, the discussion of methods of improving off-site reliability does not include requirements for facilities not under the operator's control. Sections 4 to 11 of this Guide provide information, recommendations and requirements that would apply to any emergency power system, be it electric or non-electric

  14. An updated assessment of the prospects for fuel cell-powered buses. An information paper

    Energy Technology Data Exchange (ETDEWEB)

    Sanderson, T.K. [Future Energy Solutions, Harwell (United Kingdom)

    2005-07-01

    This report presents updated conclusions of the Department of Trade and Industry's research and development programme to assess the commercial prospects for advanced fuel cells in buses. The programme has focussed on low temperature solid polymer fuel cells (SPFCs) for transport and combined heat and power (CHP)/distributed power and high temperature solid oxide fuel cells (SOFCs) for CHP/distributed power. As well as assessing the prospects for SPFCs in buses, the report examines those for alkaline fuel cells (AFCs) and phosphoric acid fuel cells (PAFCs) in buses. The report provides an assessment of the status of technology development for different types of fuel cells in terms of applications to buses and offers estimates of market potential. Some fuel-cell powered buses are now available for demonstration purposes but the report concludes that truly commercial sales are unlikely to start before 2010 and widespread deployment is expected to take a further ten years after that. Buses have now slipped behind cars in terms of worldwide deployment. The issue of fuel choice is considered largely resolved with most fleet vehicle/bus manufacturers currently focussing on hydrogen as a fuel. A discussion of the prospects and barriers for fuel cell buses concludes that cost reduction is now the major barrier to the successful commercialisation of fuel cells in buses. More demonstration prototypes and field trials are required to provide information on energy, environmental and economic performance of fuel cell buses. Field trials could also provide information to assist the development of refuelling systems, fuel storage systems, stacks and other system components and to gain experience of building integrated fuel cell systems.

  15. On-Site Detection as a Countermeasure to Chemical Warfare/Terrorism.

    Science.gov (United States)

    Seto, Y

    2014-01-01

    On-site monitoring and detection are necessary in the crisis and consequence management of wars and terrorism involving chemical warfare agents (CWAs) such as sarin. The analytical performance required for on-site detection is mainly determined by the fatal vapor concentration and volatility of the CWAs involved. The analytical performance for presently available on-site technologies and commercially available on-site equipment for detecting CWAs interpreted and compared in this review include: classical manual methods, photometric methods, ion mobile spectrometry, vibrational spectrometry, gas chromatography, mass spectrometry, sensors, and other methods. Some of the data evaluated were obtained from our experiments using authentic CWAs. We concluded that (a) no technologies perfectly fulfill all of the on-site detection requirements and (b) adequate on-site detection requires (i) a combination of the monitoring-tape method and ion-mobility spectrometry for point detection and (ii) a combination of the monitoring-tape method, atmospheric pressure chemical ionization mass spectrometry with counterflow introduction, and gas chromatography with a trap and special detectors for continuous monitoring. The basic properties of CWAs, the concept of on-site detection, and the sarin gas attacks in Japan as well as the forensic investigations thereof, are also explicated in this article. Copyright © 2014 Central Police University.

  16. Phonon transmission and thermal conductance in one-dimensional system with on-site potential disorder

    International Nuclear Information System (INIS)

    Ma Songshan; Xu Hui; Deng Honggui; Yang Bingchu

    2011-01-01

    The role of on-site potential disorder on phonon transmission and thermal conductance of one-dimensional system is investigated. We found that the on-site potential disorder can lead to the localization of phonons, and has great effect on the phonon transmission and thermal conductance of the system. As on-site potential disorder W increases, the transmission coefficients decrease, and approach zero at the band edges. Corresponding, the thermal conductance decreases drastically, and the curves for thermal conductance exhibit a series of steps and plateaus. Meanwhile, when the on-site potential disorder W is strong enough, the thermal conductance decreases dramatically with the increase of system size N. We also found that the efficiency of reducing thermal conductance by increasing the on-site potential disorder strength is much better than that by increasing the on-site potential's amplitude. - Highlights: → We studied the effect of on-site potential disorder on thermal transport. → Increasing disorder will decrease thermal transport. → Increasing system size will also decrease its thermal conductance. → Increasing disorder is more efficient than other in reducing thermal conductance.

  17. Do On-Site Mental Health Professionals Change Pediatricians' Responses to Children's Mental Health Problems?

    Science.gov (United States)

    McCue Horwitz, Sarah; Storfer-Isser, Amy; Kerker, Bonnie D; Szilagyi, Moira; Garner, Andrew S; O'Connor, Karen G; Hoagwood, Kimberly E; Green, Cori M; Foy, Jane M; Stein, Ruth E K

    2016-01-01

    To assess the availability of on-site mental health professionals (MHPs) in primary care; to examine practice/pediatrician characteristics associated with on-site MHPs; and to determine whether the presence of on-site MHPs is related to pediatricians' comanaging or more frequently identifying, treating/managing, or referring mental health (MH) problems. Analyses included American Academy of Pediatrics (AAP) members who participated in an AAP Periodic Survey in 2013 and who practiced general pediatrics (n = 321). Measures included sociodemographics, practice characteristics, questions about on-site MHPs, comanagement of MH problems, and pediatricians' behaviors in response to 5 prevalent MH problems. Weighted univariate, bivariate, and multivariable analyses were performed. Thirty-five percent reported on-site MHPs. Practice characteristics (medical schools, universities, health maintenance organizations, managed, or referred 5 common child MH problems. Among the subset of pediatricians who reported comanaging, there was an association with comanagement when the on-site MHP was a child psychiatrist, substance abuse counselor, or social worker. On-site MHPs are more frequent in settings where low-income children are served and where pediatricians train. Pediatricians who comanage MH problems are more likely to do so when the on-site MHP is a child psychiatrist, substance abuse counselor, or social worker. Overall, on-site MHPs were not associated with comanagement or increased likelihood of pediatricians identifying, treating/managing, or referring children with 5 common child MH problems. Copyright © 2016 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  18. On-site gamma dose rates at the Andreeva Bay shore technical base, northwest Russia.

    Science.gov (United States)

    Reistad, O; Dowdall, M; Standring, W J F; Selnaes, Ø G; Hustveit, S; Steinhusen, F; Sørlie, A

    2008-07-01

    The spent nuclear fuel (SNF) and radioactive waste (RAW) storage facility at Andreeva Bay shore technical base (STB) is one of the largest and most hazardous nuclear legacy sites in northwest Russia. Originally commissioned in the 1960s the facility now stores large amounts of SNF and RAW associated with the Russian Northern Fleet of nuclear powered submarines. The objective of the present study was to map ambient gamma dose rates throughout the facility, in particular at a number of specific sites where SNF and RAW are stored. The data presented here are taken from a Norwegian-Russian collaboration enabling the first publication in the scientific literature of the complete survey of on-site dose rates. Results indicate that elevated gamma dose rates are found primarily at discrete sites within the facility; maximum dose rates of up to 1000 microSv/h close to the ground (0.1m) and up to 3000 microSv/h at 1m above ground were recorded, higher doses at the 1m height being indicative primarily of the presence of contaminated equipment as opposed to ground contamination. Highest dose rates were measured at sites located in the immediate vicinity of buildings used for storing SNF and sites associated with storage of solid and liquid radioactive wastes. Elevated dose rates were also observed near the former channel of a small brook that became heavily contaminated as a result of radioactive leaks from the SNF storage at Building 5 starting in 1982. Isolated patches of elevated dose rates were also observed throughout the STB. A second paper detailing the radioactive soil contamination at the site is published in this issue of Journal of Environmental Radioactivity.

  19. Postulated accident scenarios for the on-site transport of spent nuclear fuel

    International Nuclear Information System (INIS)

    Morandin, G.; Sauve, R.

    2004-01-01

    Once a spent fuel container is loaded with spent fuel it typically travels on-site to a processing building for permanent lid attachment. During on-site transport a lid clamp is utilized to ensure the container lid remains in place. The safe on-site transport of spent nuclear fuel must rely on the structural integrity of the transport container and system of transport. Regard for on-site traffic and safe, efficient travel routes are important and manageable with well thought-out planning. Non-manageable incidences, such as flying debris from tornado force winds or postulated blasts in proximity to the transport container, that may result in high velocity impact and shock loading on the transport system must be considered. This paper consists of simulations that consider these types of postulated accident scenarios using detailed nonlinear finite element techniques

  20. Comparison of conventional vs. modular hydrogen refueling stations and on-site production vs. delivery.

    Energy Technology Data Exchange (ETDEWEB)

    Hecht, Ethan S. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Pratt, Joseph William [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2017-03-01

    To meet the needs of public and private stakeholders involved in the development, construction, and operation of hydrogen fueling stations needed to support the widespread roll-out of hydrogen fuel cell electric vehicles, this work presents publicly available station templates and analyses. These ‘Reference Stations’ help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enable quick assessment of potential sites for a hydrogen station, identify contributors to poor economics, and suggest areas of research. This work presents layouts, bills of materials, piping and instrumentation diagrams, and detailed analyses of five new station designs. In the near term, delivered hydrogen results in a lower cost of hydrogen compared to on-site production via steam methane reforming or electrolysis, although the on-site production methods have other advantages. Modular station concepts including on-site production can reduce lot sizes from conventional assemble-on-site stations.

  1. 76 FR 2144 - Quest Diagnostics, Inc. Information Technology Help Desk Services Including On-Site Leased...

    Science.gov (United States)

    2011-01-12

    .... Information Technology Help Desk Services Including On-Site Leased Workers From Modis, West Norriton, PA..., applicable to workers of Quest Diagnostics, Inc., Information Technology Help Desk Services, West Norriton... Quest Diagnostics, Inc., Information Technology Help Desk [[Page 2145

  2. 75 FR 49526 - Halliburton Company, Duncan Mfg., Including On-Site Leased Workers from Express Personnel...

    Science.gov (United States)

    2010-08-13

    ... Company, Duncan Mfg., Including On-Site Leased Workers from Express Personnel, Clayton Personnel Service, and Manpower Planning, Duncan, OK; Halliburton Company, Technology and Engineering Division, Finance... Halliburton Company, Technology and Engineering Division, and Finance and Administration Division, Duncan...

  3. Wilderness Recreation Demand: A Comparison of Travel Cost and On-Site Cost Models

    Science.gov (United States)

    J.M. Bowker; A. Askew; L. Seymour; J.P. Zhu; D. English; C.M. Starbuck

    2009-01-01

    This study used travel cost and on-site day cost models, coupled with the Forest Service’s National Visitor Use Monitoring data, to examine the demand for and value of recreation access to designated Wilderness.

  4. 76 FR 13666 - Pitney Bowes, Inc., Mailing Solutions Management, Global Engineering Group, Including On-Site...

    Science.gov (United States)

    2011-03-14

    ...., Mailing Solutions Management, Global Engineering Group, Including On-Site Leased Workers From Guidant... workers and former workers of Pitney Bowes, Inc., Mailing Solutions Management Division, Engineering... reviewed the certification to clarify the subject worker group's identity. Additional information revealed...

  5. On-Site Processing and Subsampling of Surface Soil Samples for the Analysis of Explosives

    National Research Council Canada - National Science Library

    Hewitt, Alan D

    2003-01-01

    The on-site implementation of a sampling and analysis plan for the determination of explosives residues exposed a large uncertainty in our ability to quickly obtain representative subsamples from either large (>500 g...

  6. AMCO On-Site Air Monitoring Map Service, Oakland CA, Live 2017, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — This map service contains the following layers: All On-Site Air Monitors, TCE, PCE, and Vinyl Chloride. The layers draws at all scales. Full FGDC metadata for the...

  7. Acoustic-Seismic Coupling in Porous Ground - Measurements and Analysis for On-Site-Inspection Support

    Science.gov (United States)

    Liebsch, Mattes; Gorschlüter, Felix; Altmann, Jürgen

    2014-05-01

    acoustic signals and geophones were buried in different depths to measure the soil velocity. Additionally, a wooden box coated with acoustic damping foam was placed over some acoustic and seismic sensors to reduce the power of incident acoustic signals and thus the locally created seismic vibrations (under the box). The reduced soil velocity measured by geophones under the box corresponds mainly to vibrations created by acoustic-seismic coupling outside the box which travel through the soil and reach the sensor. Under certain conditions of frequency and incident angle of acoustic signals an increased seismic response was observed. This might indicate the excitation of seismic surface waves and is of special interest for the evaluation. The project aims to deliver a better understanding of the interaction of acoustic waves with the ground when hitting the surface. Recommendations for sensitive seismic measurements during CTBTO on-site inspections will be developed to reduce disturbing vibrations caused by airborne sources.

  8. On-site SiH4 generator using hydrogen plasma generated in slit-type narrow gap

    Science.gov (United States)

    Takei, Norihisa; Shinoda, Fumiya; Kakiuchi, Hiroaki; Yasutake, Kiyoshi; Ohmi, Hiromasa

    2018-06-01

    We have been developing an on-site silane (SiH4) generator based on use of the chemical etching reaction between solid silicon (Si) and the high-density H atoms that are generated in high-pressure H2 plasma. In this study, we have developed a slit-type plasma source for high-efficiency SiH4 generation. High-density H2 plasma was generated in a narrow slit-type discharge gap using a 2.45 GHz microwave power supply. The plasma’s optical emission intensity distribution along the slit was measured and the resulting distribution was reflected by both the electric power distribution and the hydrogen gas flow. Because the Si etching rate strongly affects the SiH4 generation rate, the Si etching behavior was investigated with respect to variations in the experimental parameters. The weight etch rate increased monotonically with increasing input microwave power. However, the weight etch rate decreased with increasing H2 pressure and an increasing plasma gap. This reduction in the etch rate appears to be related to shrinkage of the plasma generation area because increased input power is required to maintain a constant plasma area with increasing H2 pressure and the increasing plasma gap. Additionally, the weight etch rate also increases with increasing H2 flow rate. The SiH4 generation rate of the slit-type plasma source was also evaluated using gas-phase Fourier transform infrared absorption spectroscopy and the material utilization efficiencies of both Si and the H2 gas for SiH4 gas formation were discussed. The main etch product was determined to be SiH4 and the developed plasma source achieved a SiH4 generation rate of 10 sccm (standard cubic centimeters per minute) at an input power of 900 W. In addition, the Si utilization efficiency exceeded 60%.

  9. Phosphoric acid fuel cell platinum use study

    Science.gov (United States)

    Lundblad, H. L.

    1983-05-01

    The U.S. Department of Energy is promoting the private development of phosphoric acid fuel cell (PAFC) power plants for terrestrial applications. Current PAFC technology utilizes platinum as catalysts in the power electrodes. The possible repercussions that the platinum demand of PAFC power plant commercialization will have on the worldwide supply and price of platinum from the outset of commercialization to the year 2000 are investigated. The platinum demand of PAFC commercialization is estimated by developing forecasts of platinum use per unit of generating capacity and penetration of PAFC power plants into the electric generation market. The ability of the platinum supply market to meet future demands is gauged by assessing the size of platinum reserves and the capability of platinum producers to extract, refine and market sufficient quantities of these reserves. The size and timing of platinum price shifts induced by the added demand of PAFC commercialization are investigated by several analytical methods. Estimates of these price shifts are then used to calculate the subsequent effects on PAFC power plant capital costs.

  10. Evaluation of the OnSite malaria rapid test performance in Miandrivazo, Madagascar.

    Science.gov (United States)

    Ravaoarisoa, E; Andriamiandranoro, T; Raherinjafy, R; Jahevitra, M; Razanatsiorimalala, S; Andrianaranjaka, V; Randrianarivelojosia, M

    2017-10-01

    The performance of the malaria rapid diagnostic test OnSite-for detecting pan specific pLDH and Plasmodium falciparum specific HRP2 - was assessed during the malaria transmission peak period in Miandrivazo, in the southwestern part of Madagascar from April 20 to May 6, 2010. At the laboratory, the quality control OnSite Malaria Rapid Test according to the WHO/TDR/FIND method demonstrated that the test had good sensitivity. Of the 218 OnSite tests performed at the Miandrivazo Primary Health Center on patients with fever or a recent history of fever, four (1.8%, 95% CI: 0.6-4.9%) were invalid. Ninety four (43,1%) cases of malaria were confirmed by microscopy, of which 90 were P. falciparum malaria and 4 Plasmodium vivax malaria. With a Cohen's kappa coefficient of 0.94, the agreement between microscopy and OnSite is excellent. Compared with the rapid test CareStart™ commonly used within the public health structures in Madagascar, the sensitivity and specificity of the OnSite test were 97.9% and 96.8%.

  11. Slope stability and bearing capacity of landfills and simple on-site test methods.

    Science.gov (United States)

    Yamawaki, Atsushi; Doi, Yoichi; Omine, Kiyoshi

    2017-07-01

    This study discusses strength characteristics (slope stability, bearing capacity, etc.) of waste landfills through on-site tests that were carried out at 29 locations in 19 sites in Japan and three other countries, and proposes simple methods to test and assess the mechanical strength of landfills on site. Also, the possibility of using a landfill site was investigated by a full-scale eccentric loading test. As a result of this, landfills containing more than about 10 cm long plastics or other fibrous materials were found to be resilient and hard to yield. An on-site full scale test proved that no differential settlement occurs. The repose angle test proposed as a simple on-site test method has been confirmed to be a good indicator for slope stability assessment. The repose angle test suggested that landfills which have high, near-saturation water content have considerably poorer slope stability. The results of our repose angle test and the impact acceleration test were related to the internal friction angle and the cohesion, respectively. In addition to this, it was found that the air pore volume ratio measured by an on-site air pore volume ratio test is likely to be related to various strength parameters.

  12. 77 FR 70484 - Preoperational Testing of Onsite Electric Power Systems To Verify Proper Load Group Assignments...

    Science.gov (United States)

    2012-11-26

    ...-1294, ``Preoperational Testing of On-Site Electric Power Systems to Verify Proper Load Group... entitled ``Preoperational Testing of On- Site Electric Power Systems to Verify Proper Load Group... Electric Power Systems to Verify Proper Load Group Assignments, Electrical Separation, and Redundancy...

  13. On-site and laboratory evaluations of soundscape quality in recreational urban spaces

    DEFF Research Database (Denmark)

    Bjerre, Lærke Cecilie; Larsen, Thea Mathilde; Sørensen, Anna Josefine

    2017-01-01

    Regulations for quiet urban areas are typically based on sound level limits alone. However, the nonacoustic context may be crucial for subjective soundscape quality. Aims: This study aimed at comparing the role of sound level and nonacoustic context for subjective urban soundscape assessment...... in the presence of the full on-site context, the visual context only, and without context. Materials and Methods: Soundscape quality was evaluated for three recreational urban spaces by using four subjective attributes: loudness, acceptance, stressfulness, and comfort. The sound level was measured at each site......, the availability of the visual context in the listening experiment had no significant effect on the ratings. The participants were overall more positive toward natural sound sources on site. Conclusion: The full immersion in the on-site nonacoustic context may be important when evaluating overall soundscape...

  14. Effects of Edge on-Site Potential in a Honeycomb Topological Magnon Insulator

    Science.gov (United States)

    Pantaleón, Pierre A.; Xian, Yang

    2018-06-01

    While the deviation of the edge on-site potential from the bulk values in a magnonic topological honeycomb lattice leads to the formation of edge states in a bearded boundary, this is not the case for a zigzag termination, where no edge state is found. In a semi-infinite lattice, the intrinsic on-site interactions along the boundary sites generate an effective defect and this gives rise to Tamm-like edge states. If a nontrivial gap is induced, both Tamm-like and topologically protected edge states appear in the band structure. The effective defect can be strengthened by an external on-site potential, and the dispersion relation, velocity and magnon density of the edge states all become tunable.

  15. 76 FR 19466 - Masco Builder Cabinet Group Including On-Site Leased Workers From Reserves Network, Reliable...

    Science.gov (United States)

    2011-04-07

    ... Builder Cabinet Group Including On-Site Leased Workers From Reserves Network, Reliable Staffing, and Third Dimension Waverly, OH; Masco Builder Cabinet Group Including On-Site Leased Workers From Reserves Network... Group including on-site leased workers from Reserves Network, Jackson, Ohio. The workers produce...

  16. 77 FR 40638 - Syniverse Technologies, Inc., Including On-Site Leased Workers From Insight Global Stone Staffing...

    Science.gov (United States)

    2012-07-10

    ..., Inc., Including On-Site Leased Workers From Insight Global Stone Staffing, and Randstad Formerly Known..., Massachusetts, including on-site leased workers from Insight Global, Stone Staffing, Randstad formerly known as... Insight Global, Stone Staffing, Randstad, formerly known as Sapphire Technologies, were employed on-site...

  17. 77 FR 29362 - Kohler Company, Malvern Division, Including On-Site Leased Workers From Manpower Staffing and Dow...

    Science.gov (United States)

    2012-05-17

    ... Division, Including On-Site Leased Workers From Manpower Staffing and Dow Cleaning Services, Malvern, AR..., and components. The company reports that workers from Dow Cleaning Services were employed on-site at... leased from Dow Cleaning Services working on-site at the Malvern, Arkansas location of Kohler Company...

  18. 75 FR 26793 - Beam Global Spirits & Wine, Including On-Site Leased Workers from Adecco, St. Elizabeth Business...

    Science.gov (United States)

    2010-05-12

    ... & Wine, Including On-Site Leased Workers from Adecco, St. Elizabeth Business Health, Guardsmark, and Lab... 26, 2010, applicable to workers of Beam Global Spirits & Wine, including on-site leased workers from... on-site at the Cincinnati, Ohio location of Beam Global Spirits & Wine. The Department has determined...

  19. Innovative on-site approach to oil based drilling mud waste management

    International Nuclear Information System (INIS)

    Laurell, A.

    1999-01-01

    An innovative system has been developed by Unique Oilfield Technology Services (UNOTEC) for the environmentally safe containment and decomposition of oily drilling residuals. The approach is a complete management system which provides an on-site alternative to off-site disposal. The approach uses the principles of total containment and microbial decomposition of hydrocarbons. The complete management system transforms the waste into an end product suitable for on-site land treatment, in accordance with regulatory guidelines. This paper describes how the approach can eliminate the future environmental risk and economic liability associated with hydrocarbon contaminated materials

  20. Methods for estimating on-site ambient air concentrations at disposal sites

    International Nuclear Information System (INIS)

    Hwang, S.T.

    1987-01-01

    Currently, Gaussian type dispersion modeling and point source approximation are combined to estimate the ambient air concentrations of pollutants dispersed downwind of an areawide emission source, using the approach of virtual point source approximation. This Gaussian dispersion modeling becomes less accurate as the receptor comes closer to the source, and becomes inapplicable for the estimation of on-site ambient air concentrations at disposal sites. Partial differential equations are solved with appropriate boundary conditions for use in estimating the on-site concentrations in the ambient air impacted by emissions from an area source such as land disposal sites. Two variations of solution techniques are presented, and their predictions are compared

  1. Compact solitary waves in linearly elastic chains with non-smooth on-site potential

    Energy Technology Data Exchange (ETDEWEB)

    Gaeta, Giuseppe [Dipartimento di Matematica, Universita di Milano, Via Saldini 50, 20133 Milan (Italy); Gramchev, Todor [Dipartimento di Matematica e Informatica, Universita di Cagliari, Via Ospedale 72, 09124 Cagliari (Italy); Walcher, Sebastian [Lehrstuhl A Mathematik, RWTH Aachen, 52056 Aachen (Germany)

    2007-04-27

    It was recently observed by Saccomandi and Sgura that one-dimensional chains with nonlinear elastic interaction and regular on-site potential can support compact solitary waves, i.e. travelling solitary waves with strictly compact support. In this paper, we show that the same applies to chains with linear elastic interaction and an on-site potential which is continuous but non-smooth at minima. Some different features arise; in particular, the speed of compact solitary waves is not uniquely fixed by the equation. We also discuss several generalizations of our findings.

  2. On site PWR fuel inspection measurements for operational and design verification

    International Nuclear Information System (INIS)

    1996-01-01

    The on-site inspection of irradiated Pressurized Water Reactor (PWR) fuel and Non-Fuel Bearing Components (NFBC) is typically limited to visual inspections during refuelings using underwater TV cameras and is intended primarily to confirm whether the components will continue in operation. These inspections do not normally provide data for design verification nor information to benefit future fuel designs. Japanese PWR utilities and Nuclear Fuel Industries Ltd. designed, built, and performed demonstration tests of on-site inspection equipment that confirms operational readiness of PWR fuel and NFBC and also gathers data for design verification of these components. 4 figs, 3 tabs

  3. TechSolutions 11: An Introduction to Power and Energy

    Science.gov (United States)

    2009-01-01

    facilitate ionic conduction under hydrated conditions. The operating temperature for PEMFCs is relatively cool (70°C). The reactions on the anode and...cathode side of the FC are the same as those shown for PAFCs. Direct methanol fuel cells (DMFCs) are a subset of PEMFCs . These FCs utilize the same...an electrically E58 The AMMTIAC Quarterly, Volume 4, Number 1 Figure 7. Diagram of a PEMFC .[47] 1 Hydrogen fuel is channeled through field flow

  4. Cost-effective on-site screening for anaemia in pregnancy in primary ...

    African Journals Online (AJOL)

    syphilis serology. Results are returned days or weeks later depending on local circumstances.2 For some mobile clinics in rural areas, this delay may be as long as a month. On-site screening for ... probably anaemic still require a diagnostic test to determine ... accurate and cheap screening for and diagnosis of anaemia,.

  5. 76 FR 14101 - Meadwestvaco Corporation, Consumer and Office Products Division, Including On-Site Leased Workers...

    Science.gov (United States)

    2011-03-15

    ... undated planning and organizing products. The review shows that on August 21, 2008, a certification of..., Consumer and Office Products Division, Including On-Site Leased Workers From Pro-Tel People, Sidney, NY; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with...

  6. Test methods for on site measurement of resistivity of concrete. A RILEM TC-154 Technical Recommendation

    NARCIS (Netherlands)

    Polder, R.B.

    2000-01-01

    This paper describes methods to assess concrete resistivity on site for various purposes related to corrosion and protection of reinforcement. It is based on a first draft of a RILEM Technical Recommendation. The electrical resistivity of concrete can be related to the two processes involved in

  7. Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-06-01

    Axillary ultrasonography (AUS) and fine-needle aspiration cytology (FNAC) can establish axillary lymph node status before surgery, although this technique is hampered by poor adequacy rates. To achieve consistently high rates of FNAC adequacy, rapid on-site evaluation (ROSE) of FNAC samples was introduced.

  8. 76 FR 73683 - Whirlpool Corporation, Including On-Site Leased Workers From Career Solutions TEC Staffing...

    Science.gov (United States)

    2011-11-29

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,593] Whirlpool Corporation, Including On-Site Leased Workers From Career Solutions TEC Staffing, Andrews International, IBM Corporation... refrigerators and trash compactors. The notice was published in the Federal Register on October 25, 2010 (75 FR...

  9. 76 FR 72978 - Whirlpool Corporation Including On-Site Leased Workers From Career Solutions TEC Staffing...

    Science.gov (United States)

    2011-11-28

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,593] Whirlpool Corporation Including On-Site Leased Workers From Career Solutions TEC Staffing, Andrews International, IBM Corporation... workers are engaged in the production of refrigerators and trash compactors. The notice was published in...

  10. Solitary heat waves in nonlinear lattices with squared on-site potential

    Indian Academy of Sciences (India)

    A model Hamiltonian is proposed for heat conduction in a nonlinear lattice with squared on-site potential using the second quantized operators and averaging the same using a suitable wave function, equations are derived in discrete form for the field amplitude and the properties of heat transfer are examined theoretically.

  11. Solitary heat waves in nonlinear lattices with squared on-site potential

    Indian Academy of Sciences (India)

    Abstract. A model Hamiltonian is proposed for heat conduction in a nonlinear lattice with squared on-site potential using the second quantized operators and averaging the same using a suitable wave function, equations are derived in discrete form for the field amplitude and the prop- erties of heat transfer are examined ...

  12. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    El Haddad, J. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Villot-Kadri, M.; Ismaël, A.; Gallou, G. [IVEA Solution, Centre Scientifique d' Orsay, Bât 503, 91400 Orsay (France); Michel, K.; Bruyère, D.; Laperche, V. [BRGM, Service Métrologie, Monitoring et Analyse, 3 avenue Claude Guillemin, B.P 36009, 45060 Orléans Cedex (France); Canioni, L. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Bousquet, B., E-mail: bruno.bousquet@u-bordeaux1.fr [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France)

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced.

  13. 75 FR 11922 - Apria Healthcare, Including On-Site Leased Workers From Corestaff, Ultimate Staffing (Roth...

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,054C] Apria Healthcare..., 2009, applicable to workers of Apria Healthcare, including on-site leased workers from Corestaff... subject firm. The workers are engaged in activities related to the information technology and patient...

  14. 40 CFR 266.108 - Small quantity on-site burner exemption.

    Science.gov (United States)

    2010-07-01

    ...) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.108... burn hazardous waste in an on-site boiler or industrial furnace are exempt from the requirements of...

  15. 75 FR 76487 - Haldex Brake Corporation, Commercial Vehicle Systems, Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-08

    ..., Commercial Vehicle Systems, Including On-Site Leased Workers of Johnston Integration Technologies, a... Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974, as amended (``Act''), 19 U.S.C... system components. The company reports that workers leased from Johnston Integration Technologies, a...

  16. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    El Haddad, J.; Villot-Kadri, M.; Ismaël, A.; Gallou, G.; Michel, K.; Bruyère, D.; Laperche, V.; Canioni, L.; Bousquet, B.

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced

  17. Towards sustainable and robust on-site domestic wastewater treatment for all citizens

    NARCIS (Netherlands)

    Mgana, S.

    2003-01-01

    In most developing countries commonly practiced domestic wastewater treatment systems predominantly constitute anaerobic treatment process. The anaerobic treatment units mostly installed are on-site at residential dwellings.

    However the commonly installed units, viz., traditional pit

  18. 77 FR 48550 - Technicolor Creative Services, Post Production Feature Mastering Division Including On-Site...

    Science.gov (United States)

    2012-08-14

    ... Services, Post Production Feature Mastering Division Including On-Site Leased Workers From Ajilon... Services, Post Production Feature Mastering Division, Hollywood, California (subject firm). The worker... the workers meet the eligibility requirements of the Trade Act of 1974. Conclusion After careful...

  19. The interactive on-site inspection system: An information management system to support arms control inspections

    Energy Technology Data Exchange (ETDEWEB)

    DeLand, S.M.; Widney, T.W.; Horak, K.E.; Caudell, R.B.; Grose, E.M.

    1996-12-01

    The increasing use of on-site inspection (OSI) to meet the nation`s obligations with recently signed treaties requires the nation to manage a variety of inspection requirements. This document describes a prototype automated system to assist in the preparation and management of these inspections.

  20. On-site energy consumption and selected emissions at softwood sawmills in the southwestern United States

    Science.gov (United States)

    Dan Loeffler; Nathaniel Anderson; Todd A. Morgan; Colin B. Sorenson

    2016-01-01

    Presently there is a lack of information describing US southwestern energy consumption and emissions generated from the sawmilling industry. This article uses a mail survey of softwood sawmills in the states of Arizona, Colorado, and New Mexico to develop a profile of on-site energy consumption and selected emissions for the industry. Energy consumption is...

  1. Improvement of Endovascular Stroke Treatment: A 24-Hour Neuroradiological On-Site Service Is Not Enough

    Directory of Open Access Journals (Sweden)

    Omid Nikoubashman

    2018-01-01

    Full Text Available Background and Purpose. With the advent of endovascular stroke treatment (EST with mechanical thrombectomy, stroke treatment has also become more challenging. Purpose of this study was to investigate whether a fulltime neuroradiological on-site service and workflow optimization with a structured documentation of the interdisciplinary stroke workflow resulted in improved procedural times. Material and Methods. Procedural times of 322 consecutive patients, who received EST (1 before (n=96 and (2 after (n=126 establishing a 24-hour neuroradiological on-site service as well as (3 after implementation of a structured interdisciplinary workflow documentation (“Stroke Check” (n=100, were analysed. Results. A fulltime neuroradiological on-site service resulted in a nonsignificant improvement of procedural times during out-of-hours admissions (p≥0.204. Working hours and out-of-hours procedural times improved significantly, if additional workflow optimization was realized (p≤0.026. Conclusions. A 24-hour interventional on-site service is a major prerequisite to adequately provide modern reperfusion therapies in patients with acute ischemic stroke. However, simple measures like standardized and focused documentation that affect the entire interdisciplinary pre- and intrahospital stroke rescue chain seem to be important.

  2. Design considerations for on-site spent-fuel transfer systems

    International Nuclear Information System (INIS)

    Jones, R.H.; Jones, C.R.

    1989-06-01

    Studies on spent fuel shipping logistics and operation make it clear that the use of large casks, i.e., 100--125 tons, is superior to smaller casks of similar construction. This superiority manifests itself in both transportation and/or shipping economics and safety as well as reduced personnel exposure in the processing of the casks. An on-site system for the transfer of spent fuel from the storage pool to a large shipping or storage cask, as well as the transfer of spent fuel directly from a storage cask to a shipping cask, could bring the large cask benefits to those restricted reactors. Sensing the need to look more closely at this opportunity, EPRI contracted with S. Levy, Incorporated of Campbell, CA to develop a set of design considerations for such transfer systems. Rather then embark on another design study, EPRI decided to first identify the system considerations that must be factored into any design. The format for this effort presents both the Consideration and the Rationale for the consideration. The resulting work identified thirty-six General Considerations and two Special Considerations. The Considerations are in the form of mandatory requirements and desirable but nonmandatory requirements. Additionally, a brief economic study was performed to get a feel for the cost considerations of on-site transfers. The study results suggest a relatively narrow set of scenarios where on-site transfers are economically superior to alternatives. These scenarios generally involve the use of concrete casks as on-site storage devices

  3. 78 FR 52982 - Regal Beloit Corporation; Springfield, Missouri Division Including On-site Leased Workers From...

    Science.gov (United States)

    2013-08-27

    ... these workers were sufficiently under the control of the subject firm to be considered leased workers...; Springfield, Missouri Division Including On-site Leased Workers From Penmac Personnel Services and GCA Services Group Springfield, Missouri; Amended Certification Regarding Eligibility to Apply for Worker...

  4. 75 FR 77664 - Honeywell International, Inc., Automation and Control Solutions Division, Including On-Site...

    Science.gov (United States)

    2010-12-13

    ..., Inc., Automation and Control Solutions Division, Including On-Site Leased Workers From Manpower... Solutions Division. The Department has determined that these workers were sufficiently under the control of Honeywell International, Inc., Automation and Control Solutions Division to be considered leased workers...

  5. On-Site Enzyme Production by Trichoderma asperellum for the Degradation of Duckweed

    DEFF Research Database (Denmark)

    Bech, Lasse; Herbst, Florian-Alexander; Grell, Morten Nedergaard

    2015-01-01

    The on-site production of cell wall degrading enzymes is an important strategy for the development of sustainable bio-refinery processes. This study concerns the optimization of production of plant cell wall-degrading enzymes produced by Trichoderma asperellum. A comparative secretome analysis...

  6. 76 FR 19467 - Weyerhaeuser Company, Corporate Headquarters Including On-Site Leased Workers From Volt Services...

    Science.gov (United States)

    2011-04-07

    ... employed on-site at the Federal Way, Washington location of Weyerhaeuser Company, Corporate Headquarters... Company, Corporate Headquarters to be considered leased workers. Based on these findings, the Department... Federal Way, Washington location of Weyerhaeuser Company, Corporate Headquarters. The amended notice...

  7. 78 FR 8587 - Thomson Reuters, Finance Operations & Technology Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-02-06

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,755] Thomson Reuters, Finance Operations & Technology Division, Including On-Site Leased Workers From Adecco; Eagan, MN; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974, as amended (`...

  8. Enhanced On-Site Waste Management of Plasterboard in Construction Works: A Case Study in Spain

    Directory of Open Access Journals (Sweden)

    Ana Jiménez-Rivero

    2017-03-01

    Full Text Available On-site management of construction waste commonly determines its destination. In the case of plasterboard (PB, on-site segregation becomes crucial for closed-loop recycling. However, PB is commonly mixed with other wastes in Spain. In this context, the involvement of stakeholders that can contribute to reversing this current situation is needed. This paper analyzes on-site waste management of PB in Spain through a pilot study of a construction site, with the main objective of identifying best practices to increase waste prevention, waste minimization, and the recyclability of the waste. On-site visits and structured interviews were conducted. The results show five management stages: PB distribution (I; PB installation (II; Construction waste storage at the installation area (III; PB waste segregation at the installation area (IV and PB waste transfer to the PB container and storage (V. The proposed practices refer to each stage and include the merging of Stages III and IV. This measure would avoid the mixing of waste fractions in Stage III, maximizing the recyclability of PB. In addition, two requisites for achieving enhanced management are analyzed: ‘Training and commitment’ and ‘fulfilling the requirements established by the current regulation’. The results show that foremen adopted a more pessimistic attitude than installers towards a joint commitment for waste management. Moreover, not all supervisors valued the importance of a site waste management plan, regulated by the Royal Decree 105/2008 in Spain.

  9. Finding New Water: Development of On-Site Non-Potable Water Reuse Systems

    Science.gov (United States)

    By designing our buildings to collect and treat water generated on-site, can be and reused for flushing our toilets and irrigating our landscaping. Several water sources are generated with-in a building including: rainwater, stormwater, graywater, blackwater and foundation drain...

  10. Pathogen Treatment Guidance and Monitoring Approaches fro On-Site Non-Potable Water Reuse

    Science.gov (United States)

    On-site non-potable water reuse is increasingly used to augment water supplies, but traditional fecal indicator approaches for defining and monitoring exposure risks are limited when applied to these decentralized options. This session emphasizes risk-based modeling to define pat...

  11. 2009 Melbourne metropolitan sewerage strategy: a portfolio of decentralised and on-site concept designs.

    Science.gov (United States)

    Brown, V; Jackson, D W; Khalifé, M

    2010-01-01

    The bulk and retail water companies of the greater Melbourne area are developing the 2009 Metropolitan Sewerage Strategy to provide sustainable sewerage services to 2060. The objective of the strategy is to establish long term principles and near term actions to produce a robust sewage management system for Melbourne. Melbourne's existing sewerage system is largely centralised and discharges to two major treatment plants. Several small satellite treatment plants service local urban areas generally more distant from the centralised system. Decentralised and on-site wastewater systems are options for future sewage management and could play a role in local recycling. A portfolio of 18 on-site and decentralised concept designs was developed, applicable to the full range of urban development types in Melbourne. The concepts can be used in evaluation of metropolitan system configurations as part of future integrated water cycle planning. The options included secondary and tertiary treatment systems incorporating re-use of water for non potable uses, urine separation, black and greywater separation and composting toilets. On-site and cluster treatment systems were analysed. Each option is described by its indicative capital and operating costs, energy use and water and nutrient balances. This paper summarises and compares the portfolio mix of decentralized and on-site options in Melbourne's context.

  12. Alternative Wastewater Treatment: On-Site Bio-treatment Wetlands at the Fernald Preserve Visitors Center

    International Nuclear Information System (INIS)

    Homer, J.; Glassmeyer, C.; Sauer, N.; Powell, J.

    2009-01-01

    This paper describes the design and operation of a constructed on-site bio-treatment wetland at the Fernald Preserve Visitors Center. The use of constructed wetlands for treatment of domestic wastewater at the Fernald Preserve contributed to the award of Leadership in Energy and Environmental Design platinum certification from the U.S. Green Building Council. (authors)

  13. Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Hassan Taghipour

    2016-10-01

    Full Text Available Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative.

  14. On-site screening for syphilis at an antenatal clinic | Delport | South ...

    African Journals Online (AJOL)

    Objective. To determine the validity, predictive value and accuracy of the rapid plasma reagin card test performed on site to diagnose active syphilis in pregnant women so that immediate treatment can be offered to prevent congenital syphilis. Design. Open, descriptive study. Setting. Antenatal clinic, Mamelodi Hospital, ...

  15. On-site screening for maternal syphilis in an antenatal clinic

    African Journals Online (AJOL)

    Abstract Study objective. To determine the sensitivity, specificity, negative predictive value and positive predictive value of the rapid plasma reagin (RPR) test as performed on site in an antenatal clinic to facilitate immediate diagnosis and treatment of maternal syphilis. Design. Open, descriptive study. Setting. Antenatal ...

  16. On-site screening for maternal syphilis in an antenatal clinic ...

    African Journals Online (AJOL)

    Study objective. To determine the sensitivity, specificity, negative predictive value and positive predictive value of the rapid plasma reagin (RPR) test as performed on site in an antenatal clinic to facilitate immediate diagnosis and treatment of maternal syphilis. Design. Open, descriptive study. Setting. Antenatal clinic ...

  17. On-site and off-site forensic analysis capabilities for proliferation and terrorism prevention

    International Nuclear Information System (INIS)

    Whipple, R.E.; Nunes, P.J.; Reynolds, J.G.; Alcaraz, A.; Hart, B.R.

    2004-01-01

    Full text: We will present current on-site technologies that can be utilized for the screening of explosives, chemical agents, and environmental contaminants. These techniques must have the capability to detect various hazardous materials at very low levels, since they pose a major challenge for first responders. Specifically, the technology must detect concealed explosives or chemical agents on-site rapidly. Lawrence Livermore National Laboratory (LLNL) is currently developing several different high explosive screening and detection technologies for field use. Two technologies that have demonstrated an ability to screen for explosives at low levels are colorimetric spot tests and thin layer chromatography (TLC). Another technology that has demonstrated usefulness for the on-site analysis of unknowns is portable gas chromatography-mass spectrometry (GC-MS) with solid phase micro-extraction (SPME) sampling. Several examples utilizing these technologies and their usefulness will be presented. In addition to developing on-site screening methods, LLNL is an Organization for the Prohibition of Chemical Weapons (OPCW) designated laboratory and is certified to accept CW suspect samples. Currently, LLNL is expanding its ISO-17025 certification to include nuclear forensics and explosives. These off-site forensic analysis capabilities and certified procedures will support the needs for homeland security. We will highlight some of the ISO-17025 requirements to accredit procedures, handle samples, and reports. Work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract W-7405-ENG-48

  18. On-site and off-site forensic analysis capabilities for proliferation and terrorism prevention

    International Nuclear Information System (INIS)

    Hart, B.R.; Whipple, R.E.; Nunes, P.J.; Reynolds, J.G.; Alcaraz, A.

    2004-01-01

    We present current on-site technologies that can be utilized for the screening of explosives, chemical agents, and environmental contaminants. These techniques must have the capability to detect various hazardous materials at very low levels, since they pose a major challenge for first responders. Specifically, the technology must detect concealed explosives or chemical agents on-site rapidly. Lawrence Livermore National Laboratory (LLNL) is currently developing several different high explosive screening and detection technologies for field use. Two technologies that have demonstrated an ability to screen for explosives at low levels are colorimetric spot tests and thin layer chromatography (TLC). Another technology that has demonstrated usefulness for the on-site analysis of unknowns is portable gas chromatography-mass spectrometry (GC-MS) with solid phase micro-extraction (SPME) sampling. Several examples utilizing these technologies and their usefulness will be presented. In addition to developing on-site screening methods, LLNL is an Organization for the Prohibition of Chemical Weapons (OPCW) designated laboratory and is certified to accept CW suspect samples. Currently, LLNL is expanding its ISO-17025 certification to include nuclear forensics and explosives. These off-site forensic analysis capabilities and certified procedures will support the needs for homeland security. We will highlight some of the ISO-17025 requirements to accredit procedures, handle samples, and reports. Work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract W-7405-ENG-48. (author)

  19. Decision precision or holistic heuristic?: Insights on on-site selection of student nurses and midwives.

    Science.gov (United States)

    Macduff, Colin; Stephen, Audrey; Taylor, Ruth

    2016-01-01

    Concerns about quality of care delivery in the UK have led to more scrutiny of criteria and methods for the selection of student nurses. However few substantive research studies of on-site selection processes exist. This study elicited and interpreted perspectives on interviewing processes and related decision making involved in on-site selection of student nurses and midwives. Individual and focus group interviews were undertaken with 36 lecturers, 5 clinical staff and 72 students from seven Scottish universities. Enquiry focused primarily on interviewing of candidates on-site. Qualitative content analysis was used as a primary strategy, followed by in-depth thematic analysis. Students had very mixed experiences of interview processes. Staff typically took into account a range of candidate attributes that they valued in order to achieve holistic assessments. These included: interpersonal skills, team working, confidence, problem-solving, aptitude for caring, motivations, and commitment. Staff had mixed views of the validity and reliability of interview processes. A holistic heuristic for overall decision making predominated over belief in the precision of, and evidence base for, particular attribute measurement processes. While the development of measurement tools for particular attributes continues apace, tension between holism and precision is likely to persist within on-site selection procedures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. 75 FR 70688 - Actel Corporation, Currently Known as Microsemi Corporation, Including On-Site Leased Workers...

    Science.gov (United States)

    2010-11-18

    ..., Accountants, Inc. and Accountant Temps Mountain View, CA; Amended Certification Regarding Eligibility To Apply... on-site leased workers from ATR International, Accountants, Inc., and Accountant Temps, Mountain View... a separate unemployment insurance (UI) tax account under the name Microsemi Corporation. Accordingly...

  1. Facilitating Employee Recruitment and Retention through On-Site Child Day Care.

    Science.gov (United States)

    Lombardo, Kathy A.

    An early childhood educator at a 360-bed community general hospital implemented a licensed on-site child care program for children between 6 weeks and 10 years of age in order to improve employee recruitment and retention by assisting employees with appropriate child care arrangements. A parent questionnaire was used to assess the degree to which…

  2. GMP-conformant on-site manufacturing of a CD133+ stem cell product for cardiovascular regeneration.

    Science.gov (United States)

    Skorska, Anna; Müller, Paula; Gaebel, Ralf; Große, Jana; Lemcke, Heiko; Lux, Cornelia A; Bastian, Manuela; Hausburg, Frauke; Zarniko, Nicole; Bubritzki, Sandra; Ruch, Ulrike; Tiedemann, Gudrun; David, Robert; Steinhoff, Gustav

    2017-02-10

    CD133 + stem cells represent a promising subpopulation for innovative cell-based therapies in cardiovascular regeneration. Several clinical trials have shown remarkable beneficial effects following their intramyocardial transplantation. Yet, the purification of CD133 + stem cells is typically performed in centralized clean room facilities using semi-automatic manufacturing processes based on magnetic cell sorting (MACS®). However, this requires time-consuming and cost-intensive logistics. CD133 + stem cells were purified from patient-derived sternal bone marrow using the recently developed automatic CliniMACS Prodigy® BM-133 System (Prodigy). The entire manufacturing process, as well as the subsequent quality control of the final cell product (CP), were realized on-site and in compliance with EU guidelines for Good Manufacturing Practice. The biological activity of automatically isolated CD133 + cells was evaluated and compared to manually isolated CD133 + cells via functional assays as well as immunofluorescence microscopy. In addition, the regenerative potential of purified stem cells was assessed 3 weeks after transplantation in immunodeficient mice which had been subjected to experimental myocardial infarction. We established for the first time an on-site manufacturing procedure for stem CPs intended for the treatment of ischemic heart diseases using an automatized system. On average, 0.88 × 10 6 viable CD133 + cells with a mean log 10 depletion of 3.23 ± 0.19 of non-target cells were isolated. Furthermore, we demonstrated that these automatically isolated cells bear proliferation and differentiation capacities comparable to manually isolated cells in vitro. Moreover, the automatically generated CP shows equal cardiac regeneration potential in vivo. Our results indicate that the Prodigy is a powerful system for automatic manufacturing of a CD133 + CP within few hours. Compared to conventional manufacturing processes, future clinical application of

  3. Investigating the potential benefits of on-site food safety training for Folklorama, a temporary food service event.

    Science.gov (United States)

    Mancini, Roberto; Murray, Leigh; Chapman, Benjamin J; Powell, Douglas A

    2012-10-01

    Folklorama in Winnipeg, Manitoba, Canada, is a 14-day temporary food service event that explores the many different cultural realms of food, food preparation, and entertainment. In 2010, the Russian pavilion at Folklorama was implicated in a foodborne outbreak of Escherichia coli O157 that caused 37 illnesses and 18 hospitalizations. The ethnic nature and diversity of foods prepared within each pavilion presents a unique problem for food inspectors, as each culture prepares food in their own very unique way. The Manitoba Department of Health and Folklorama Board of Directors realized a need to implement a food safety information delivery program that would be more effective than a 2-h food safety course delivered via PowerPoint slides. The food operators and event coordinators of five randomly chosen pavilions selling potentially hazardous food were trained on-site, in their work environment, focusing on critical control points specific to their menu. A control group (five pavilions) did not receive on-site food safety training and were assessed concurrently. Public health inspections for all 10 pavilions were performed by Certified Public Health Inspectors employed with Manitoba Health. Critical infractions were assessed by means of standardized food protection inspection reports. The results suggest no statistically significant difference in food inspection scores between the trained and control groups. However, it was found that inspection report results increased for both the control and trained groups from the first inspection to the second, implying that public health inspections are necessary in correcting unsafe food safety practices. The results further show that in this case, the 2-h food safety course delivered via slides was sufficient to pass public health inspections. Further evaluations of alternative food safety training approaches are warranted.

  4. A Comparison of Online versus On-site Training in Health Research Methodology: A Randomized Study

    Directory of Open Access Journals (Sweden)

    Kanchanaraksa Sukon

    2011-06-01

    Full Text Available Abstract Background Distance learning may be useful for building health research capacity. However, evidence that it can improve knowledge and skills in health research, particularly in resource-poor settings, is limited. We compared the impact and acceptability of teaching two distinct content areas, Biostatistics and Research Ethics, through either on-line distance learning format or traditional on-site training, in a randomized study in India. Our objective was to determine whether on-line courses in Biostatistics and Research Ethics could achieve similar improvements in knowledge, as traditional on-site, classroom-based courses. Methods Subjects: Volunteer Indian scientists were randomly assigned to one of two arms. Intervention: Students in Arm 1 attended a 3.5-day on-site course in Biostatistics and completed a 3.5-week on-line course in Research Ethics. Students in Arm 2 attended a 3.5-week on-line course in Biostatistics and 3.5-day on-site course in Research Ethics. For the two course formats, learning objectives, course contents and knowledge tests were identical. Main Outcome Measures: Improvement in knowledge immediately and 3-months after course completion, compared to baseline. Results Baseline characteristics were similar in both arms (n = 29 each. Median knowledge score for Biostatistics increased from a baseline of 49% to 64% (p Conclusion On-line and on-site training formats led to marked and similar improvements of knowledge in Biostatistics and Research Ethics. This, combined with logistical and cost advantages of on-line training, may make on-line courses particularly useful for expanding health research capacity in resource-limited settings.

  5. Experience in verification regimes. United States On-Site Inspection Agency

    International Nuclear Information System (INIS)

    Reppert, J.

    1998-01-01

    Experiences are described of the United States On-site Inspection Agency in verification regimes all over the world where it has been applied in the last 30 years. The challenge for the future is to extend the benefits of the applied tools to all states in all regions to enhance stability and to create conditions for peace at lower levels of armaments than currently exist. The USA need to engage states currently caught in cycles of violence and arms escalation. They must examine technologies which together with on-site aspects of verification or transparency regimes can provide a comprehensive picture at affordable costs. They foresee a growth in combined training with new states entering for the first time into regime that include arms control and transparency measure

  6. Generation, on-site storage; handling and processing of industrial waste of Tehran

    International Nuclear Information System (INIS)

    Abduli, M.A.

    1997-01-01

    This paper describes out the present status of generation, on-site handling, processing and storage of industrial waste in Tehran. In this investigation, 67 large scale factories of different industrial groups were randomly selected. Above cited functional elements of these factories were surveyed. In this investigation a close contact with each factory was required, thus a questionnaire was prepared and distributed among these factories. The relationship between daily weight of the industrial waste (Y) and number of employer of each factory (x) is found to be Y=547.4 + 0.58 x. The relationship between daily volume of industrial waste (V), and daily weight of waste generated in each factory (Y) can be described by V=1.56 + 0.00078 Y. About 68% of the factories have their own interim storage site and the rest of the factories do not possess any on-site storage facility

  7. Procurement Specifications Templates for On-Site Solar Photovoltaic: For Use in Developing Federal Solicitations

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-01-16

    With the increasing adaption of on-site renewable energy systems designed to feed site loads, there is a critical need to develop tools that allow the federal sector to become a mature and sophisticated consumer. This document is intended to reduce project development and operational risks while increasing the speed at which projects are completed; two necessary components to reach the scale required to meet mandates and achieve cost savings for taxpayers. This guide is intended to act as a living document where lessons learned from the increasing number of projects can be incorporated and provide guidance for efforts. While additional guides will be developed to cover other renewable technologies, this guide covers on-site solar photovoltaic systems with an emphasis on third-party designed, financed, owned, and operated systems.

  8. Comparing the Scoring of Human Decomposition from Digital Images to Scoring Using On-site Observations.

    Science.gov (United States)

    Dabbs, Gretchen R; Bytheway, Joan A; Connor, Melissa

    2017-09-01

    When in forensic casework or empirical research in-person assessment of human decomposition is not possible, the sensible substitution is color photographic images. To date, no research has confirmed the utility of color photographic images as a proxy for in situ observation of the level of decomposition. Sixteen observers scored photographs of 13 human cadavers in varying decomposition stages (PMI 2-186 days) using the Total Body Score system (total n = 929 observations). The on-site TBS was compared with recorded observations from digital color images using a paired samples t-test. The average difference between on-site and photographic observations was -0.20 (t = -1.679, df = 928, p = 0.094). Individually, only two observers, both students with human decomposition based on digital images can be substituted for assessments based on observation of the corpse in situ, when necessary. © 2017 American Academy of Forensic Sciences.

  9. Recent chemical engineering requirements as the result of TMI on-site experience

    International Nuclear Information System (INIS)

    Brooksbank, R.E. Sr.

    1980-01-01

    From the experiences gained from the on-site experience at TMI, it is apparent that the role of chemical engineers should increase in order for the nuclear option to proceed in a safe and efficient fashion. It is also obvious that as the results of the reports investigating the causes and effects of the accident come to light and attempts to backfit system designs to prevent a recurrence are studied, more technical demands will be placed on the profession

  10. Rapid on-site detection of Acidovorax citrulli by cross-priming amplification.

    Science.gov (United States)

    Zhang, Jing; Tian, Qian; Zhu, Shui-fang; Zhao, Wen-jun; Liu, Feng-quan

    2012-08-01

    Cross-priming amplification (CPA) for Acidovorax citrulli detection was evaluated in this study. The sensitivity of CPA assay for pure bacterial culture was 3.7 × 10(3) CFU/ml. Bacteria on naturally infected watermelon seeds were detected using CPA assay, suggesting this method is suitable for A. citrulli on-site detection from watermelon seeds. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. On-site interim storage of spent nuclear fuel: Emerging public issues

    International Nuclear Information System (INIS)

    Feldman, D.L.; Tennessee Univ., Knoxville, TN

    1992-01-01

    Failure to consummate plans for a permanent repository or above- ground interim Monitored Retrievable Storage (MRS) facility for spent nuclear fuel has spurred innovative efforts to ensure at-reactor storage in an environmentally safe and secure manner. This article examines the institutional and socioeconomic impacts of Dry Cask Storage Technology (DCST)-an approach to spent fuel management that is emerging as the preferred method of on-site interim spent fuel storage by utilities that exhaust existing storage capacity

  12. Framatome recent developments and application on site in NDE of steam generator tubes

    International Nuclear Information System (INIS)

    Bieth, M.

    1986-01-01

    The increasing needs concerning the follow up and expertise of PWR steam generator (SG) tubing have led Framatome to develop a quick on-site intervention mobile unit, which could implement any current technique and equipment. Besides, Framatome has developed several non destructrive examination methods to solve the specific problems encountered in service on the SG tubes: profilometry of the SG tubes by eddy current. Inside and above the tube sheet, eddy current inspection of tube sleeving by ultrasonic testing and eddy current

  13. Assessment of On-site sanitation system on local groundwater regime in an alluvial aquifer

    Science.gov (United States)

    Quamar, Rafat; Jangam, C.; Veligeti, J.; Chintalapudi, P.; Janipella, R.

    2017-12-01

    The present study is an attempt to study the impact of the On-site sanitation system on the groundwater sources in its vicinity. The study has been undertaken in the Agra city of Yamuna sub-basin. In this context, sampling sites (3 nos) namely Pandav Nagar, Ayodhya Kunj and Laxmi Nagar were selected for sampling. The groundwater samples were analyzed for major cations, anions and faecal coliform. Critical parameters namely chloride, nitrate and Faecal coliform were considered to assess the impact of the On-site sanitation systems. The analytical results shown that except for chloride, most of the samples exceeded the Bureau of Indian Standard limits for drinking water for all the other analyzed parameters, i.e., nitrate and faecal coliform in the first two sites. In Laxmi Nagar, except for faecal coliform, all the samples are below the BIS limits. In all the three sites, faecal coliform was found in majority of the samples. A comparison of present study indicates that the contamination of groundwater in alluvial setting is less as compared to hard rock where On-site sanitation systems have been implemented.

  14. On-Site Chiropractic Care as an Employee Benefit: A Single-Location Case Study.

    Science.gov (United States)

    Minicozzi, Salvatore J; Russell, Brent S

    2017-09-01

    The purpose of this report is to describe the role of on-site chiropractic care in one corporate environment. A part-time chiropractic practice that provides services to a single company on site, 1 day per week, is described. Most care is oriented toward "wellness," is paid for by the employer, and is limited only by the chiropractor's few weekly hours of on-site availability. With approval from the company, the authors conducted an absenteeism analysis after obtaining ethics approval and consent from employee-patients who received care between 2012 and 2014. Comparisons of absenteeism rates of the sample were compared with lost worktime rates from the US Bureau of Labor Statistics' Labor Force Statistics. Of 40 current employees, 35 used chiropractic services; 17 employee-patients met the inclusion criteria. The lost worktime rates of those using chiropractic services (0.72%, 0.55%, and 0.67%, for 2012, 2013, and 2014, respectively) were lower than corresponding rates from Labor Force Statistics (1.5%, 1.2%, and 1.1%). Absenteeism for the employee-patients was lower than equivalent national figures in this sample of workers. Though these results may or may not be related to the chiropractic care, these findings prompt further investigation into this relationship.

  15. Propagation of transition fronts in nonlinear chains with non-degenerate on-site potentials

    Science.gov (United States)

    Shiroky, I. B.; Gendelman, O. V.

    2018-02-01

    We address the problem of transition front propagation in chains with a bi-stable nondegenerate on-site potential and a nonlinear gradient coupling. For generic nonlinear coupling, one encounters a special regime of transitions, characterized by extremely narrow fronts, far supersonic velocities of the front propagation, and long waves in the oscillatory tail. This regime can be qualitatively associated with a shock wave. The front propagation can be described with the help of a simple reduced-order model; the latter delivers a kinetic law, which is almost not sensitive to the fine details of the on-site potential. Besides, it is possible to predict all main characteristics of the transition front, including its velocity, as well as the frequency and the amplitude of the oscillatory tail. Numerical results are in good agreement with the analytical predictions. The suggested approach allows one to consider the effects of an external pre-load, the next-nearest-neighbor coupling and the on-site damping. When the damping is moderate, it is possible to consider the shock propagation in the damped chain as a perturbation of the undamped dynamics. This approach yields reasonable predictions. When the damping is high, the transition front enters a completely different asymptotic regime of a subsonic kink. The gradient nonlinearity generically turns negligible, and the propagating front converges to the regime described by a simple exact solution for a continuous model with linear coupling.

  16. Shielding requirements on-site loading and acceptance testing on the Leksell gamma knife

    International Nuclear Information System (INIS)

    Maitz, A.H.; Lunsford, L.D.; Wu, A.; Lindner, G.; Flickinger, J.C.

    1990-01-01

    On August 14, 1987, the first stereotactic radiosurgical procedure using the gamma knife was performed in North America. Located in a self-contained radiosurgical suite in the basement of Presbyterian-University Hospital in Pittsburgh, Pennsylvania. This device uses 201 highly focused beams 60Co for the single-treatment closed-skull irradiation of brain lesions localized by stereotactic techniques (radiosurgery). One hundred and fifty-two patients with intracranial arteriovenous malformations or brain tumors were treated in the first year of operation. The Presbyterian University Hospital of Pittsburgh gamma knife is the first such unit in which the 60Co sources were loaded on-site. This effort required us to solve some difficult and unusual problems encountered during site preparation, delivery, and loading of the unit in a busy hospital setting. The solutions developed enabled installation and use of the gamma knife with minimal disruption of hospital activities while maintaining acceptable levels of exposure to radiation. Environmental surveys performed during the loading of the 201 radioactive sources (total, 219 TBq) confirmed that on-site loading is possible and practical. Our experience in the design, construction, and implementation of the first North American gamma knife supports the practicality and safety of on-site loading and may be of value in the planning and development of future gamma knife installations

  17. On-site customization of silicone stents: towards optimal palliation of complex airway conditions.

    Science.gov (United States)

    Breen, David P; Dutau, Hervé

    2009-01-01

    Stents may be indicated as treatment of benign and malignant conditions of the central airways. Occasionally, aberrant and/or distorted airways secondary to therapy or surgery may preclude the use of commercially manufactured stents. The customization of stents is well described for nonpulmonary diseases, but to date there are only limited data in the literature on prosthesis customization for airway disease. To review all the different techniques and indications of on-site silicone stent customizations and their related complications. A retrospective study was undertaken to identify all patients who underwent treatment with a silicone stent which was customized on site by the physician. The study included subjects treated during an 8-year period. Forty-nine on-site customizations were performed in 43 patients (34 males, mean age 63 +/- 5.2 years). Stent customization was performed in 5.4% of the cases. Stent customization was performed for malignant and benign disease in 35 (81.3%) and 8 (18.7%) cases, respectively. In all cases, the stent deployed successfully and performed well while in situ. Stent manipulation did not increase complications. Customization of airway stents by the physician can lead to successful stenting of difficult airway lesions with a good short-term safety profile. Standard commercially available stents may have resulted in suboptimal management of complex airway pathologies. A prospective study is warranted to further investigate the safety profile and complications associated with stent customization. Copyright 2009 S. Karger AG, Basel.

  18. A microfabricated, low dark current a-Se detector for measurement of microplasma optical emission in the UV for possible use on-site

    Science.gov (United States)

    Abbaszadeh, Shiva; Karim, Karim S.; Karanassios, Vassili

    2013-05-01

    Traditionally, samples are collected on-site (i.e., in the field) and are shipped to a lab for chemical analysis. An alternative is offered by using portable chemical analysis instruments that can be used on-site (i.e., in the field). Many analytical measurements by optical emission spectrometry require use of light-sources and of spectral lines that are in the Ultra-Violet (UV, ~200 nm - 400 nm wavelength) region of the spectrum. For such measurements, a portable, battery-operated, fiber-optic spectrometer equipped with an un-cooled, linear, solid-state detector may be used. To take full advantage of the advanced measurement capabilities offered by state-of-the-art solid-state detectors, cooling of the detector is required. But cooling and other thermal management hamper portability and use on-site because they add size and weight and they increase electrical power requirements. To address these considerations, an alternative was implemented, as described here. Specifically, a microfabricated solid-state detector for measurement of UV photons will be described. Unlike solid-state detectors developed on crystalline Silicon, this miniaturized and low-cost detector utilizes amorphous Selenium (a-Se) as its photosensitive material. Due to its low dark current, this detector does not require cooling, thus it is better suited for portable use and for chemical measurements on-site. In this paper, a microplasma will be used as a light-source of UV photons for the a-Se detector. For example, spectra acquired using a microplasma as a light-source will be compared with those obtained with a portable, fiber-optic spectrometer equipped with a Si-based 2080-element detector. And, analytical performance obtained by introducing ng-amounts of analytes into the microplasma will be described.

  19. CHP in Switzerland from 1990 to 1998. Thermal power generation including combined heat and power

    International Nuclear Information System (INIS)

    Kaufmann, U.

    1999-01-01

    The results of a study on thermal power generation in Switzerland show that combined heat and power (CHP) systems have grown rapidly. Statistics are presented on the development of CHP-based power and also on thermal power stations without waste heat usage. Figures are given for gas and steam turbine installations, combined gas and steam turbine stations and motor-driven CHP units. Power production is categorised, separating small and large (over 1 Megawatt electrical) power generation facilities. On-site, distributed power generation at consumers' premises and the geographical distribution of plant is described

  20. Application of Thermoelectric Devices to Fuel Cell Power Generation: Demonstration and Evaluation

    National Research Council Canada - National Science Library

    Huston, John; Wyatt, Chris; Nichols, Chris; Binder, Michael J; Holcomb, Franklin H

    2004-01-01

    The Department of Defense (DOD) is concerned with reliable and cost-effective power generation of on-site power generators as well as minimizing the environment impact of these generators. Thermoelectric (TE...

  1. Lessons Learned from the On-Site Disposal Facility at Fernald Closure Project

    International Nuclear Information System (INIS)

    Kumthekar, U.A.; Chiou, J.D.

    2006-01-01

    The On-Site Disposal Facility (OSDF) at the U.S. Department of Energy's (DOE) Fernald Closure Project near Cincinnati, Ohio is an engineered above-grade waste disposal facility being constructed to permanently store low level radioactive waste (LLRW) and treated mixed LLRW generated during Decommissioning and Demolition (D and D) and soil remediation performed in order to achieve the final land use goal at the site. The OSDF is engineered to store 2.93 million cubic yards of waste derived from the remediation activities. The OSDF is intended to isolate its LLRW from the environment for at least 200 years and for up to 1,000 years to the extent practicable and achievable. Construction of the OSDF started in 1997 and waste placement activities will complete by the middle of April 2006 with the final cover (cap) placement over the last open cell by the end of Spring 2006. An on-site disposal alternative is considered critical to the success of many large-scale DOE remediation projects throughout the United States. However, for various reasons this cost effective alternative is not readily available in many cases. Over the last ten years Fluor Fernald Inc. has cumulated many valuable lessons learned through the complex engineering, construction, operation, and closure processes of the OSDF. Also in the last several years representatives from other DOE sites, State agencies, as well as foreign government agencies have visited the Fernald site to look for proven experiences and practices, which may be adapted for their sites. This paper present a summary of the major issues and lessons leaned at the Fernald site related to engineering, construction, operation, and closure processes for the disposal of remediation waste. The purpose of this paper is to share lessons learned and to benefit other projects considering or operating similar on-site disposal facilities from our successful experiences. (authors)

  2. WE-G-BRA-05: IROC Houston On-Site Audits and Parameters That Affect Performance

    Energy Technology Data Exchange (ETDEWEB)

    Kry, S; Dromgoole, L; Alvarez, P; Lowenstein, J; Molineu, A; Taylor, P; Followill, D [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To highlight the IROC Houston on-site dosimetry audit program, and to investigate the impact of clinical conditions on the frequency of errors/recommendations noted by IROC Houston. Methods: The results of IROC Houston on-site audits from 2000-present were abstracted and compared to clinical parameters, this included 409 institutions and 1020 linacs. In particular, we investigated the frequency of recommendations versus year, and the impact of repeat visits on the number of recommendations. We also investigated the impact on the number of recommendations of several clinical parameters: the number and age of the linacs, the linac/TPS combination, and the scope of the QA program. Results: The number of recommendations per institution (3.1 average) has shown decline between 2000 and present, although the number of recommendations per machine (0.89) has not changed. Previous IROC Houston site visits did not Result in fewer recommendations on a repeat visit, but IROC Houston tests have changed substantially during the last 15 years as radiotherapy technology has changed. There was no impact on the number of recommendations based on the number of machines at the institution or the age of a given machine. The fewest recommendations were observed for Varian-Eclipse combinations (0.71 recs/machine), while Elekta- Pinnacle combinations yielded the most (1.62 recs/machine). Finally, in the TG-142 era (post-2010), those institutions that had a QA recommendation (n=77) had significantly more other recommendations (1.83 per institution) than those that had no QA rec (n=12, 1.33 per institution). Conclusion: Establishing and maintaining a successful radiotherapy program is challenging and areas of improvement can routinely be identified. Clinical conditions such as linac-TPS combinations and the establishment of a good QA program impact the frequency of errors/deficiencies identified by IROC Houston during their on-site review process.

  3. WE-G-BRA-05: IROC Houston On-Site Audits and Parameters That Affect Performance

    International Nuclear Information System (INIS)

    Kry, S; Dromgoole, L; Alvarez, P; Lowenstein, J; Molineu, A; Taylor, P; Followill, D

    2015-01-01

    Purpose: To highlight the IROC Houston on-site dosimetry audit program, and to investigate the impact of clinical conditions on the frequency of errors/recommendations noted by IROC Houston. Methods: The results of IROC Houston on-site audits from 2000-present were abstracted and compared to clinical parameters, this included 409 institutions and 1020 linacs. In particular, we investigated the frequency of recommendations versus year, and the impact of repeat visits on the number of recommendations. We also investigated the impact on the number of recommendations of several clinical parameters: the number and age of the linacs, the linac/TPS combination, and the scope of the QA program. Results: The number of recommendations per institution (3.1 average) has shown decline between 2000 and present, although the number of recommendations per machine (0.89) has not changed. Previous IROC Houston site visits did not Result in fewer recommendations on a repeat visit, but IROC Houston tests have changed substantially during the last 15 years as radiotherapy technology has changed. There was no impact on the number of recommendations based on the number of machines at the institution or the age of a given machine. The fewest recommendations were observed for Varian-Eclipse combinations (0.71 recs/machine), while Elekta- Pinnacle combinations yielded the most (1.62 recs/machine). Finally, in the TG-142 era (post-2010), those institutions that had a QA recommendation (n=77) had significantly more other recommendations (1.83 per institution) than those that had no QA rec (n=12, 1.33 per institution). Conclusion: Establishing and maintaining a successful radiotherapy program is challenging and areas of improvement can routinely be identified. Clinical conditions such as linac-TPS combinations and the establishment of a good QA program impact the frequency of errors/deficiencies identified by IROC Houston during their on-site review process

  4. Noble Gas Sampling and Detection Methods for On-Site Inspections in Support of CTBT

    International Nuclear Information System (INIS)

    Wieslander, J.S.E.

    2015-01-01

    The On-Site Inspections (OSI) constitutes the final verification measure under the CTBT, and are conducted to verify States Parties' compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT). An on-site inspection is launched to establish whether or not a nuclear explosion has been carried out and during such an inspection, facts might also be gathered to identify a possible violator of the Treaty. The Treaty lists all activities and techniques that are permitted and one of these is the environmental sampling of noble gases (NG) in the air and underground, which can be deployed at any time during an OSI. The CTBT relevant isotopes are Xe-133, 133m, 131m, 135 and Ar-37. The samples are primarily to be analyzed on-site, although the treaty also allows off-site analysis in designated laboratories if necessary. Stringent procedures ensure the security, integrity and confidentiality of the samples throughout the sampling and analysis process — all taking place in the field. Over the past decade the techniques for NG sampling, processing and analysis of both atmospheric and subsoil NG samples have been developed further in order to fit to the conditions and requirements during an OSI. This has been a major international effort with a global set of collaborators. Especially during the past three years the efforts intensified in order to finalize the scientific and technical developments for the Integrated Field Exercise, November 2014 (IFE14). This presentation will provide an overview of the current status of the OSI NG sampling regime and the OSI NG Field Laboratory to be deployed in IFE14, together with more technical descriptions of methods and equipment as well as a short discussion on potential future developments and alternative applications as applicable. (author)

  5. 75 FR 21353 - Intel Corporation, Fab 20 Division, Including On-Site Leased Workers From Volt Technical...

    Science.gov (United States)

    2010-04-23

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,642] Intel Corporation, Fab 20... of Intel Corporation, Fab 20 Division, including on-site leased workers of Volt Technical Resources... Precision, Inc. were employed on-site at the Hillsboro, Oregon location of Intel Corporation, Fab 20...

  6. 75 FR 76038 - Zach System Corporation a Subdivision of Zambon Company, SPA Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-07

    ... Subdivision of Zambon Company, SPA Including On-Site Leased Workers of Turner Industries and Go Johnson, La..., including on-site leased workers from Turner Industries and Go Johnson, La Porte, Texas. The Department's... investigation revealed that Zach System Corporation is a subdivision of Zambon Company, SPA, not Zach System SPA...

  7. 76 FR 16447 - ETHICON, a Subsidiary of Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary...

    Science.gov (United States)

    2011-03-23

    ... workers of ETHICON, A Johnson and Johnson Company, San Angelo, Texas, separated from employment on or... Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary Services, San Angelo, TX; Amended... of ETHICON, a subsidiary of Johnson & Johnson, including on-site leased workers from Kelly Temporary...

  8. 76 FR 27366 - CEVA Freight, LLC, Dell Logistics Division, Including On-Site Leased Workers From Prologistix...

    Science.gov (United States)

    2011-05-11

    ... Logistics Division, Including On-Site Leased Workers From Prologistix, Including Workers Whose Unemployment..., applicable to workers of CEVA Freight, LLC, Dell Logistics Division, including on-site leased workers from... workers employed at CEVA Freight, LLC, Dell Logistics Division, Winston-Salem, North Carolina who were...

  9. 75 FR 76037 - HAVI Logistics, North America a Subsidiary of HAVI Group, LP Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-07

    ... Logistics, North America a Subsidiary of HAVI Group, LP Including On-Site Leased Workers of Express Personnel Services and the La Salle Network, Bloomingdale, IL; Havi Logistics, North America, Lisle, IL..., applicable to workers of HAVI Logistics, North America, a subsidiary of HAVI Group, LP, including on-site...

  10. 75 FR 38128 - Ceva Freight, LLC, Dell Logistics Division, Including On-Site Leased Workers From Prologistix and...

    Science.gov (United States)

    2010-07-01

    ... Logistics Division, Including On-Site Leased Workers From Prologistix and Employment Staffing Solutions... 19, 2010, applicable to workers of CEVA Freight, LLC, Dell Logistics Division, including on-site..., North Carolina location of CEVA Freight, LLC, Dell Logistics Division. The Department has determined...

  11. 75 FR 55613 - Dupont Teijin Films Including On-Site Leased Workers From Schenkers Logistics, Inc., Florence, SC...

    Science.gov (United States)

    2010-09-13

    ... Including On-Site Leased Workers From Schenkers Logistics, Inc., Florence, SC; Amended Certification... Teijin Films, including on-site leased workers from Schenkers Logistics, Inc., Florence, South Carolina... leased workers of Schenkers Logistics, Inc., Florence, South Carolina, who became totally or partially...

  12. 75 FR 11921 - Heritage Aviation, Ltd., Including On-Site Leased Workers From Global Technical Services and...

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,924] Heritage Aviation, Ltd., Including On-Site Leased Workers From Global Technical Services and Global, Inc. (Global Employment... from Heritage Aviation, Ltd, including on-site leased workers from Global Technical Services, Grand...

  13. 76 FR 61741 - Bmc Software, Inc. Including On-Site Leased Workers From COMSYS ITS Including Remote Workers...

    Science.gov (United States)

    2011-10-05

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,540] Bmc Software, Inc... November 23, 2010, applicable to workers of BMC Software, Inc., including on-site leased workers from... BMC Software, inc., including on-site leased workers from Comsys ITS, and including remote workers...

  14. 76 FR 50272 - West, A Thomson Reuters Business, Thomson Reuters Legal Division, Including On-Site Leased...

    Science.gov (United States)

    2011-08-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,099] West, A Thomson Reuters Business, Thomson Reuters Legal Division, Including On-Site Leased Workers From Adecco, Albuquerque, New... former workers of West, A Thomson Reuters Business, Thomson Reuters Legal Division, including On-Site...

  15. 78 FR 2287 - Daimler Buses North America, Inc., a Subsidiary of Daimler North America Corp, Including On-Site...

    Science.gov (United States)

    2013-01-10

    ... subsidiary of Daimler North America Corp., including on-site leased workers from Noramtec, First Choice... America, Inc., a Subsidiary of Daimler North America Corp, Including On-Site Leased Workers From Noramtec, First Choice Staffing, Staff Works, and Mr. Santo Lamarco From Wurth Revcar Fasteners, Inc., Oriskany...

  16. 75 FR 453 - FLSMidth, Inc., Cement Division, Product Engineering, Including On-Site Leased Workers of Aerotek...

    Science.gov (United States)

    2010-01-05

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,048] FLSMidth, Inc., Cement..., Inc., Cement Division, Product Engineering, including on-site leased workers of Aerotek Contract.... were also employed on-site at FLSmidth, Inc., Cement Division, Product Engineering, Bethlehem...

  17. 75 FR 45166 - Jeld-Wen, Inc., Hawkins Window Division, Including On-Site Leased Workers of Nicolet Staffing...

    Science.gov (United States)

    2010-08-02

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,014] Jeld-Wen, Inc., Hawkins Window Division, Including On-Site Leased Workers of Nicolet Staffing, Hawkins, WI; Notice of Negative...., Hawkins Window Division, including on-site leased workers of Nicolet Staffing, Hawkins, Wisconsin. Signed...

  18. 78 FR 21155 - Eastman Kodak Company, IPS-Dayton Location, Including On-site Leased Workers From Adecco, Dayton...

    Science.gov (United States)

    2013-04-09

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,387] Eastman Kodak Company, IPS--Dayton Location, Including On-site Leased Workers From Adecco, Dayton, Ohio; Notice of... and former workers of Eastman Kodak Company, IPS--Dayton Location, including on-site leased workers...

  19. 77 FR 21588 - Hart and Cooley, Inc., A Subsidiary of Tomkins, PLC Including On-Site Leased Workers from...

    Science.gov (United States)

    2012-04-10

    ... Subsidiary of Tomkins, PLC Including On- Site Leased Workers from Reliable, Masiello Employment Services..., applicable to workers of Hart and Cooley, Inc., a subsidiary of Tomkins, PLC, including on-site leased... workers. Based on these findings, the Department is amending this certification to include workers leased...

  20. 77 FR 3499 - Sony Electronics, Inc., Including On-Site Leased Workers From Selectremedy Park Ridge, NJ...

    Science.gov (United States)

    2012-01-24

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,501M] Sony Electronics, Inc... Electronics, Inc., SEL Headquarters, including on-site leased workers of SelectRemedy, StaffMark, and Payrolling.com , San Diego, California (TA-W-71,501); Sony Electronics, Inc., including on-site leased...

  1. 76 FR 62452 - Avon Products, Inc. Including On-Site Leased Workers From Spherion/Source Right, Springdale, OH...

    Science.gov (United States)

    2011-10-07

    .... Including On-Site Leased Workers From Spherion/Source Right, Springdale, OH; Amended Certification Regarding... workers of the subject firm. The company reports that workers leased from Spherion/Source Right were...., including on-site leased workers from Spherion/Source Right, Springdale, Ohio, who became totally or...

  2. 76 FR 62451 - Avon Products, Inc., Including On-Site Leased Workers From Spherion/Source Right, Springdale...

    Science.gov (United States)

    2011-10-07

    ...., Including On-Site Leased Workers From Spherion/Source Right, Springdale, Ohio; Amended Certification... workers of the subject firm. The company reports that workers leased from Spherion/Source Right were...., including on-site leased workers from Spherion/Source Right, Springdale, Ohio, who became totally or...

  3. 75 FR 5147 - Acushnet Company a Subsidiary of Fortune Brands Including On-Site Leased Workers From Olsten...

    Science.gov (United States)

    2010-02-01

    ...,763B] Acushnet Company a Subsidiary of Fortune Brands Including On-Site Leased Workers From Olsten Staffing Services Fairhaven, MA; Acushnet Company a Subsidiary of Fortune Brands Including On-Site Leased Workers From Olsten Staffing Services New Bedford, MA; Acushnet Company a Subsidiary of Fortune Brands...

  4. 76 FR 2145 - International Paper Company, Franklin Pulp & Paper Mill, Including On-Site Leased Workers From...

    Science.gov (United States)

    2011-01-12

    ... Company, Franklin Pulp & Paper Mill, Including On-Site Leased Workers From Railserve, Franklin, VA..., applicable to workers and former workers of International Paper Company, Franklin Pulp & Paper Mill, Franklin... follows: All workers International Paper Company, Franklin Pulp & Paper Mill, including on-site leased...

  5. 78 FR 8587 - American Showa, Inc.; Blanchester Plant, Including On-Site Leased Workers From Adecco and Sims...

    Science.gov (United States)

    2013-02-06

    ....; Blanchester Plant, Including On-Site Leased Workers From Adecco and Sims Bros., Inc.; Blanchester, OH; Amended... workers from Sims Bros., Inc. were working on-site at the subject firm during the relevant period and that the services supplied by Sims Bros., Inc. were related to the production of gear boxes (and parts...

  6. 78 FR 61389 - Sanyo Solar of Oregon, LLC, Wafer Slicing and Quality Control Operations, Including On-Site...

    Science.gov (United States)

    2013-10-03

    ..., LLC, Wafer Slicing and Quality Control Operations, Including On-Site Leased Workers From Brown and... Quality Control Operations, Salem, Oregon, including on-site leased workers from Brown and Dunton, Inc... and included workers who supplied quality control and support functions. The company reports that...

  7. 78 FR 12358 - Cardinal Health, Financial Shared Services West, Including On-Site Leased Workers From Aerotek...

    Science.gov (United States)

    2013-02-22

    ... office financial services from India and the Philippines. Based on these findings, the Department is..., Financial Shared Services West, Including On- Site Leased Workers From Aerotek, eXcel Staffing, Experis..., applicable to workers of Cardinal Health, Financial Shared Services West, including on-site leased workers...

  8. 77 FR 62535 - Hydro Aluminum North America, Inc., Midwest Region, Including On-Site Leased Workers From...

    Science.gov (United States)

    2012-10-15

    ... Aluminum North America, Inc., Midwest Region, Including On- Site Leased Workers From Employment Group, Aerotek, and Manpower, Kalamazoo, Michigan; Hydro Aluminum North America, Inc., Midwest Region, Including... Aluminum North America, Inc., Kalamazoo, Michigan. The subject worker group includes on-site leased workers...

  9. The use of on-site Project Officers by a nuclear regulatory body

    International Nuclear Information System (INIS)

    Beare, J.W.

    1977-01-01

    In Canada consideration of applications for licensing nuclear installations is entrusted to the Reactor Safety Advisory Committee within the Atomic Energy Control Board (AECB). The licensing procedure is conducted in three stages (site approval, construction licence, operating licence). In order to control construction and operation of nuclear installations Project Officers are assigned to each particular installation. The policy of AECB is to send these officers on site several months before the reactor reaches criticality; and during reactor operation. This system clearly provides great practical advantages. (NEA) [fr

  10. Description of INR-Pitesti own strategy for on site radioactive solid waste storage concepts

    International Nuclear Information System (INIS)

    Tuturici, I.L.; Toma, V.; Bujoreanu, D.; Prava, M.

    1993-01-01

    The Post Irradiation Examination Laboratory (PIEL) produces and will produce the majority of institute's alpha-contaminated solid radioactive waste, generated by the process of examination of irradiated CANDU-600 type nuclear fuel. The wastes will be divided into three categories: low-level, medium-level, and high-level general process trash (LLGPT, MLGPT, and HLGPT). The paper describes the strategy adopted for immobilization, conditioning and on-site long-term storage of these wastes. The proposed strategy is based on the best experience acquired by other nuclear centers, confronted with same problems. (Author)

  11. Droplet-counting Microtitration System for Precise On-site Analysis.

    Science.gov (United States)

    Kawakubo, Susumu; Omori, Taichi; Suzuki, Yasutada; Ueta, Ikuo

    2018-01-01

    A new microtitration system based on the counting of titrant droplets has been developed for precise on-site analysis. The dropping rate was controlled by inserting a capillary tube as a flow resistance in a laboratory-made micropipette. The error of titration was 3% in a simulated titration with 20 droplets. The pre-addition of a titrant was proposed for precise titration within an error of 0.5%. The analytical performances were evaluated for chelate titration, redox titration and acid-base titration.

  12. On-site concrete cask storage system for spent nuclear fuel

    International Nuclear Information System (INIS)

    Craig, P.A.; Haelsig, R.T.; Kent, J.D.; Schmoker, D.S.

    1989-01-01

    A method is described of storing spent nuclear fuel assemblies including the steps of: transferring the fuel assemblies from a spent-fuel pool to a moveable concrete storage cask located outside the spent-fuel pool; maintaining a barrier between the fuel and the concrete in the cask to prevent contamination of the concrete by the fuel; maintaining the concrete storage cask containing the spent-fuel on site at the reactor complex for some predetermined period; transferring the fuel assemblies from the concrete storage cask to a shipping container; and, recycling the concrete storage cask

  13. Study of Some Innovant Reactors without on- Site Refueling with Triso and Cermet Fuel

    OpenAIRE

    A.Chetaine; A. Benchrif; H. Amsil; V. Kuznetsov; Y. Shimazu

    2012-01-01

    The evaluation of unit cell neutronic parameters and lifetime for some innovant reactors without on sit-refuling will be held in this work. the behavior of some small and medium reactors without on site refueling with triso and cermet fuel. For the FBNR long life except we propose to change the enrichment of the Cermet MFE to 9%. For the AFPR reactor we can see that the use of the Cermet MFE can extend the life of this reactor but to maintain the same life period for AFPR...

  14. On-site control of 900 and 1300 MWe nuclear reactors control rod assemblies

    International Nuclear Information System (INIS)

    Lacroix, R.; Lebuffe, C.; Bour, D.; Pasquier, T.

    1990-01-01

    To measure the external wear of clads of the RCCA rodlets in both 900 and 1300 MWe P.W.R., two on site examination tools was developed by FRAGEMA. They have been used in 42 inspections between 1986 and 1989. The examination is performed in two successive phases: - longitudinal detection of wear by eddy currents, - characterization of wear by ultrasonic profilometry. Moreover, at the instance of E.D.F., an equipment is developing by INTERCONTROLE. These measurement tools allow a suitable monitoring system adapted to the phenomenon kinetics [fr

  15. On-site emergency intervention plan for nuclear accident situation at SCN-Pitesti TRIGA Reactor

    International Nuclear Information System (INIS)

    Margeanu, S.; Oprea, I.

    2008-01-01

    A 14 MW TRIGA research reactor is operated on the Institute for Nuclear Research site. In the event of a nuclear accident or radiological emergency that may affect the public the effectiveness of protective actions depends on the adequacy of intervention plans prepared in advance. Considerable planning is necessary to reduce to manageable levels the types of decisions leading to effective responses to protect the public in such an event. The essential structures of our on-site, off-site and county emergency intervention plan and the correlation between emergency intervention plans are presented. (authors)

  16. Estimations of On-site Directional Wave Spectra from Measured Ship Responses

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2006-01-01

    include an quivalence of energy in the governing equations and, as regards the parametric concept, a frequency dependent spreading of the waves is introduced. The paper includes an extensive analysis of full-scale measurements for which the directional wave spectra are estimated by the two ship response......In general, two main concepts can be applied to estimate the on-site directional wave spectrum on the basis of ship response measurements: 1) a parametric method which assumes the wave spectrum to be composed by parameterised wave spectra, or 2) a non-parametric method where the directional wave...

  17. On-Site Fecal Sludge Treatment with the Anaerobic Digestion Pasteurization Latrine

    OpenAIRE

    Forbis-Stokes, Aaron A.; O'Meara, Patrick F.; Mugo, Wangare; Simiyu, Gelas M.; Deshusses, Marc A.

    2016-01-01

    Abstract The Anaerobic Digestion Pasteurization Latrine (ADPL) is a self-contained and energy neutral on-site sanitation system using anaerobic digestion of fecal sludge to generate biogas and then uses the biogas to pasteurize the digester effluent at 65?75?C to produce a safe effluent that can be reused locally as a fertilizer. Two ADPL systems were installed on residential plots with 17 and 35 residents in a peri-urban area outside of Eldoret, Kenya. Each system comprised three toilets bui...

  18. Chemical and microbiological investigations on mineral-oil contaminated soils following on-site regeneration measures

    International Nuclear Information System (INIS)

    Hollerbach, A.; Teschner, M.; Bosecker, K.; Wehner, H.; Kassner, H.

    1992-01-01

    In the site of a former petroleum refinery, where bombing during the second World War has caused in part deep-down contamination of the ground with petroleum and its products, a pilot study with five on-site biological treatment beds was carried through by different firms with the aim to reduce the hydrocarbon content of the soil to 1 gramme per kilogramme of dry weight. Thus, good comparability of the different regeneration measures was given. Sampling was done at the end of the regeneration experiments by obtaining an average sample. (orig.) [de

  19. Do On-site Mental Health Professionals Change Pediatricians’ Responses to Children’s Mental Health Problems?

    Science.gov (United States)

    Horwitz, Sarah McCue; Storfer-Isser, Amy; Kerker, Bonnie D.; Szilagyi, Moira; Garner, Andrew S.; O’Connor, Karen G.; Hoagwood, Kimberly E.; Green, Cori M.; Foy, Jane M.; Stein, Ruth E.K.

    2016-01-01

    Objective The objectives were to: assess the availability of on-site mental health professionals (MHP) in primary care; examine practice/pediatrician characteristics associated with on-site MHPs; and determine whether presence of on-site MHPs is related to pediatricians’ co-managing or more frequently identifying, treat/managing or referring MH problems. Methods Analyses included AAP members who participated in an AAP Periodic Survey in 2013 and who practiced general pediatrics (N=321). Measures included socio-demographics, practice characteristics, questions on about on-site MHPs, co-management of MH problems and pediatricians’ behaviors in response to 5 prevalent MH problems. Weighted univariate, bivariate and multivariable analyses were performed. Results Thirty-five percent reported on-site MHPs. Practice characteristics (medical schools/universities/HMOs, <100 visits/week, <80% of patients privately insured), and interactions of practice location (urban) with visits and patient insurance, were associated with on-site MHPs. There was no overall association between co-location and co-management or whether pediatricians usually identified, treat/managed or referred 5 common child MH problems. Among the subset of pediatricians who reported co-managing there was an association with co-management when the on-site MHP was a child psychiatrist, SA counselor, or social worker. Conclusions On-site MHPs are more frequent in settings where low-income children are served and where pediatricians train. Pediatricians who co-manage MH problems are more likely to do so when the on-site MHP is a child psychiatrist, SA counselor, or social worker. Overall, on-site MHPs were not associated with co-management or increased likelihood of pediatricians identifying, treating/managing, or referring children with 5 common child MH problems. PMID:27064141

  20. Critical management practices influencing on-site waste minimization in construction projects.

    Science.gov (United States)

    Ajayi, Saheed O; Oyedele, Lukumon O; Bilal, Muhammad; Akinade, Olugbenga O; Alaka, Hafiz A; Owolabi, Hakeem A

    2017-01-01

    As a result of increasing recognition of effective site management as the strategic approach for achieving the required performance in construction projects, this study seeks to identify the key site management practices that are requisite for construction waste minimization. A mixed methods approach, involving field study and survey research were used as means of data collection. After confirmation of construct validity and reliability of scale, data analysis was carried out through a combination of Kruskal-Wallis test, descriptive statistics and exploratory factor analysis. The study suggests that site management functions could significantly reduce waste generation through strict adherence to project drawings, and by ensuring fewer or no design changes during construction process. Provision of waste skips for specific materials and maximisation of on-site reuse of materials are also found to be among the key factors for engendering waste minimization. The result of factor analysis suggests four factors underlying on-site waste management practices with 96.093% of total variance. These measures include contractual provisions for waste minimization, waste segregation, maximisation of materials reuse and effective logistic management. Strategies through which each of the underlying measures could be achieved are further discussed in the paper. Findings of this study would assist construction site managers and other site operatives in reducing waste generated by construction activities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. On-site Labour Productivity of New Zealand Construction Industry: Key Constraints and Improvement Measures

    Directory of Open Access Journals (Sweden)

    Serdar Durdyev

    2011-09-01

    Full Text Available Productivity is key to the survival and growth of any organisation, industry or nation. Some factors constrain the achievement of the set project objectives in the New Zealand building and construction industry and are responsible for the reported steady decline of productivity and performance. This study aims to identify the key constraints to on-site labour productivity and improvement measures. Using the descriptive survey method, views of some project managers, contractors and subcontractors in New Zealand were canvassed via pilot interviews and questionnaire surveys at the qualitative and quantity data gathering stages, respectively. Multi-attribute technique was used to analyse the quantitative data. Results showed that the key external constraints to on-site labour productivity comprise, in order of decreasing impact, statutory compliance, unforeseen events and wider external dynamics. The internal constraints, which contribute 67 percent of the onsite productivity issues, comprise reworks, level of skill and experience of the workforce, adequacy of method of construction, buildability issues, and inadequate supervision and coordination. . The factors underlying each broad category of external and internal constraints are reported. The relative levels of impact of the identified constraints are expected to guide the project team in addressing the constraints in a cost-effective manner.

  2. Numerical and on-site experimental dynamic analysis of the Italian PEC fast reactor building

    International Nuclear Information System (INIS)

    Castoldi, A.; Muzzi, F.; Orsi, R.; Panzeri, P.; Pezzoli, P.; Ruggeri, G.; Martelli, A.; Masoni, P.; Brancati, V.

    1988-01-01

    On-site dynamic tests and three-dimensional numerical analysis have been performed by ISMES on behalf of ENEA on the building of the Italian PEC fast reactor test facility. These studies aimed at evaluating the safety margins in the PEC reactor seismic analysis and at providing data for the optimization of the PEC seismic monitoring system. The paper describes the on-site dynamic tests carried out using various excitation methods (two eccentric back-rotating-mass mechanical vibrator, blasting in bore-hole and hydraulic actuators at the building foundations). It highlights the purposes of the four tests campaigns performed at various construction stages and reports the main experimental results. In connection with the experimental tests, a detailed 3D finite element model was set up for fixed base analysis; from the results of the 3D model a simplified equivalent model of the structure was then derived for soil-structure interaction analysis. The mathematical model was validated and calibrated by using the results of the experimental dynamic tests. The main numerical results and the comparisons with the experimental data are presented. (author)

  3. The safeguards on-site laboratory at Sellafield. Five years operational experience

    Energy Technology Data Exchange (ETDEWEB)

    Duinslaeger, L.; Belle, P. van; Mayer, K.; Casteleyn, K.; Abousahl, S.; Daures, P.; Eberle, H.; Enright, T.; Guiot, A.; Hild, M.; Horta Domenech, J.; Lajarge, P.; Laurent, P.; Le Terrier, A.; Lynch, B.; Marucci, M.; Millet, S.; Ottmar, H.; Richir, P.; Street, S.; Vallet, P.; Zuleger, E. [European Commission, Karlsruhe (Germany). Inst. for Transuranium Elements

    2004-06-01

    The start of operation of the large reprocessing facilities led Euratom Safeguards to a new approach for verification analysis of samples taken at the facility: the installation of on-site laboratories. The availability of analytical capabilities for independent verification measurements at the site of these facilities offers obvious advantages in view of timeliness of results. The 'On-Site Laboratory' (OSL) at the BNFL Sellafield site was the first ever and entered into operation in 1999. For almost five years, the Institute for Transuranium Elements (ITU) has been operating the laboratory under routine conditions. During this period, more than one thousand safeguards samples were analysed. The experience gained in the management, logistics and operation of the OSL allow a critical review based on a significant period in time. This includes also aspects of training of staff, maintenance of equipment, flow of information, and improvements in the efficiency. The analytical issues are of key importance: based on the operational experience, the measurement methods were adapted (changing boundary conditions), the distribution of samples according to material type changed (start up of MOS fabrication plant), and the cutback in resources triggered a further streamlining of the analytical efforts. (orig.)

  4. Analytical quality control concept in the Euratom on-site laboratories

    International Nuclear Information System (INIS)

    Mayer, K.; Duinslaeger, L.; Cromboom, O.; Ottmar, H.; Wojnowski, D.; Vegt, H. van der

    2001-01-01

    Full text: Two on-site laboratories have been developed, installed, commissioned and put into routine operation by the Euratom safeguards office (ESO), jointly with the Institute for Transuranium Elements (ITU). These laboratories are operated by ITU staff and provide verification measurement results on samples taken by Euratom inspectors. The analysts work in weekly changing shift teams, manage the laboratories and operate the various analytical techniques. Operating such a laboratory at a remote location, without a senior scientist immediately available in case of problems, The existing boundary conditions challenge the robustness of the entire laboratory, i.e. comprising staff and instrumentation. In order to continuously ensure a high degree of reliability of the measurement results, a stringent quality control system was implemented. The quality control concept for the two on-site laboratories was developed at a very early stage and implemented in the pre-OSL training facility at ITU. This enabled to thoroughly test and develop further the concept. At the same time the analysts get acquainted with the quality control procedures in place and they are instilled with the principles. The quality control concept makes use of a fully computerized data management and data acquisition system. All measurement devices, including balances, density meters, mass spectrometers, passive neutron counter, hybrid K-edge instrument, gamma spectrometers and alpha spectrometers are networked and data exchange is performed on electronic basis. A specifically developed laboratory information management system collects individual measurement data, calculates intermediate and final result and shares the information with a quality control module. In order to ensure the reliability of the results, which are reported to the ESO inspectorate, five levels of quality control were implemented. The present paper describes in detail the different levels of quality control, which check the

  5. A New Tool for Automated Data Collection and Complete On-site Flux Data Processing for Eddy Covariance Measurements

    Science.gov (United States)

    Begashaw, I. G.; Kathilankal, J. C.; Li, J.; Beaty, K.; Ediger, K.; Forgione, A.; Fratini, G.; Johnson, D.; Velgersdyk, M.; Hupp, J. R.; Xu, L.; Burba, G. G.

    2014-12-01

    The eddy covariance method is widely used for direct measurements of turbulent exchange of gases and energy between the surface and atmosphere. In the past, raw data were collected first in the field and then processed back in the laboratory to achieve fully corrected publication-ready flux results. This post-processing consumed significant amount of time and resources, and precluded researchers from accessing near real-time final flux results. A new automated measurement system with novel hardware and software designs was developed, tested, and deployed starting late 2013. The major advancements with this automated flux system include: 1) Enabling logging high-frequency, three-dimensional wind speeds and multiple gas densities (CO2, H2O and CH4), low-frequency meteorological data, and site metadata simultaneously through a specially designed file format 2) Conducting fully corrected, real-time on-site flux computations using conventional as well as user-specified methods, by implementing EddyPro Software on a small low-power microprocessor 3) Providing precision clock control and coordinate information for data synchronization and inter-site data comparison by incorporating a GPS and Precision Time Protocol. Along with these innovations, a data management server application was also developed to chart fully corrected real-time fluxes to assist remote system monitoring, to send e-mail alerts, and to automate data QA/QC, transfer and archiving at individual stations or on a network level. Combination of all of these functions was designed to help save substantial amount of time and costs associated with managing a research site by eliminating the post-field data processing, reducing user errors and facilitating real-time access to fully corrected flux results. The design, functionality, and test results from this new eddy covariance measurement tool will be presented.

  6. Small Reactors without On-site Refuelling: Neutronic Characteristics, Emergency Planning and Development Scenarios. Final Report of an IAEA Coordinated Research Project

    International Nuclear Information System (INIS)

    2010-09-01

    particular research groups but produced results of common interest. Upon the advice and with the support of IAEA Member States, the IAEA provides a forum for the exchange of information by experts and policy makers from industrialized and developing countries on the technical, economic, environmental, and social aspects of SMR development and implementation in the 21st century, and makes this information available to all interested Member States by producing status reports and other publications dedicated to advances in SMR technology. The objective of this report is to document reference points and conclusions achieved through coordinated research conducted within the CRP on 'Small Reactors without On-site Refuelling' and to suggest R and D activities to be furthered after the CRP completion. Being documented, the outputs of this CRP may foster further R and D and increase the capability of Member States to achieve progress in development and deployment of small reactors without on-site refuelling. The report is intended for designers of advanced small and medium sized reactors and officers responsible for planning and implementation of R and D programmes on advanced technology development for nuclear power. Section 2 and Annex I to this report are intended also for regulators in Member States

  7. Recycling of treated domestic effluent from an on-site wastewater treatment system for hydroponics.

    Science.gov (United States)

    Oyama, N; Nair, J; Ho, G E

    2005-01-01

    An alternative method to conserve water and produce crops in arid regions is through hydroponics. Application of treated wastewater for hydroponics will help in stripping off nutrients from wastewater, maximising reuse through reduced evaporation losses, increasing control on quality of water and reducing risk of pathogen contamination. This study focuses on the efficiency of treated wastewater from an on-site aerobic wastewater treatment unit. The experiment aimed to investigate 1) nutrient reduction 2) microbial reduction and 3) growth rate of plants fed on wastewater compared to a commercial hydroponics medium. The study revealed that the chemical and microbial quality of wastewater after hydroponics was safe and satisfactory for irrigation and plant growth rate in wastewater hydroponics was similar to those grown in a commercial medium.

  8. On-site vs off-site management of environmental restoration waste: A cost effectiveness analysis

    International Nuclear Information System (INIS)

    Morse, M.A.; Aamodt, P.L.; Cox, W.B.

    1996-01-01

    The Sandia National Laboratories Environmental Restoration Project is expected to generate relatively large volumes of hazardous waste as a result of cleanup operations. These volumes will exceed the Laboratories existing waste management capacity. This paper presents four options for managing remediation wastes, including three alternatives for on-site waste management utilizing a corrective action management unit (CAMU). Costs are estimated for each of the four options based on current volumetric estimates of hazardous waste. Cost equations are derived for each of the options with the variables being waste volumes, the major unknowns in the analysis. These equations provide a means to update cost estimates as volume estimates change. This approach may be helpful to others facing similar waste management decisions

  9. On-site habitability in the event of an accident at a nuclear facility

    International Nuclear Information System (INIS)

    1989-01-01

    This publication is intended to provide technical guidance and a methodology for regulatory bodies, designers, constructors and operators of nuclear facilities to assist them in assessing the current situation as regards on-site habitability for their specific nuclear facilities. Initially, the aim will be to ensure that the ''vital areas'' of the facility which are necessary for the safe operation and shutdown of the facility will remain habitable, in some cases continuously and in others transiently, in the event of an accident inside or outside the installation. The assessment procedure can be used not only for potential radiation accidents but also to consider the effects on habitability of those probable non-radiological events which, if not correctly and effectively countered, could lead to the development of potentially unsafe conditions in the facility itself. 30 refs, 4 figs, 8 tabs

  10. Development of a portable test device for assessing on-site floor slipperiness: an interim report.

    Science.gov (United States)

    Grönqvist, R; Hirvonen, M; Rajamäki, E

    2001-04-01

    The main objective was to design and construct a prototype portable slipmeter with the capability of measuring static, transitional kinetic and steady-state kinetic coefficient of friction properties of on-site floors. The second objective was to evaluate its operation in the laboratory, using a commercial force platform as reference. The prototype was found to be capable of measuring the described frictional characteristics of floor surfaces, using three different test wheels and two modes of operation, impact and non-impact testing. The results anticipate that the slipmeter may prove to be more valid than any traditional measurement technique. The study continues with biomechanical trials and will be completed during the year 2000.

  11. Heat-flow properties of systems with alternate masses or alternate on-site potentials

    Science.gov (United States)

    Pereira, Emmanuel; Santana, Leonardo M.; Ávila, Ricardo

    2011-07-01

    We address a central issue of phononics: the search of properties or mechanisms to manage the heat flow in reliable materials. We analytically study standard and simple systems modeling the heat flow in solids, namely, the harmonic, self-consistent harmonic and also anharmonic chains of oscillators, and we show an interesting insulating effect: While in the homogeneous models the heat flow decays as the inverse of the particle mass, in the chain with alternate masses it decays as the inverse of the square of the mass difference, that is, it decays essentially as the mass ratio (between the smaller and the larger one) for a large mass difference. A similar effect holds if we alternate on-site potentials instead of particle masses. The existence of such behavior in these different systems, including anharmonic models, indicates that it is a ubiquitous phenomenon with applications in the heat flow control.

  12. On-site treatment and landfilling of MSWI air pollution control residues

    DEFF Research Database (Denmark)

    Lundtorp, Kasper; Jensen, Dorthe Lærke; Sørensen, Mette Abildgaard

    2003-01-01

    the process, collected through the drainage system, contained large concentrations of salts (Cl: 14–30 g/l, Na: 4–9 g/l, K: 5–11 g/l, Ca: 2–12 g/l) but low concentrations of trace metals (e.g. Pb: 14–100 μg/l, Cd: leaching......Air pollution control (APC) residues from municipal solid waste incineration (MSWI) are difficult to landfill due to substantial leaching of trace metals. An on-site pretreatment prior to landfilling of APC-residues was investigated in terms of bench-scale experiments with a semidry APC...... of the leaching, concentrations of trace metals were reduced by up to four orders of magnitude....

  13. A Review of On-Site Wastewater Treatment Systems in Western Australia from 1997 to 2011

    Science.gov (United States)

    Gunady, Maria; Shishkina, Natalia; Tan, Henry; Rodriguez, Clemencia

    2015-01-01

    On-site wastewater treatment systems (OWTS) are widely used in Western Australia (WA) to treat and dispose of household wastewater in areas where centralized sewerage systems are unavailable. Septic tanks, aerobic treatment units (ATUs), and composting toilets with greywater systems are among the most well established and commonly used OWTS. However, there are concerns that some OWTS installed in WA are either performing below expected standards or failing. Poorly performing OWTS are often attributed to inadequate installation, inadequate maintenance, poor public awareness, insufficient local authority resources, ongoing wastewater management issues, or inadequate adoption of standards, procedures, and guidelines. This paper is to review the installations and failures of OWTS in WA. Recommendations to the Department of Health Western Australia (DOHWA) and Local Government (LG) in regard to management strategies and institutional arrangements of OWTS are also highlighted. PMID:25960745

  14. Modeling injury rates as a function of industrialized versus on-site construction techniques.

    Science.gov (United States)

    Rubio-Romero, J C; Suárez-Cebador, M; Abad, Jesús

    2014-05-01

    It is often predicted that the industrialization of building activities will lead to a reduction of accident rates in the construction sector, particularly as a result of switching activities from building sites to factories. However, to date no scientific research has provided objective quantitative results to back up this claim. The aim of this paper is to evaluate how industrialization affects the accident rate in different industrialized building systems in Spain. Our results revealed that the industrialized steel modular system presents the lowest accident rate, while the highest accident rate was recorded in the construction method with cast-in-place concrete. The lightweight construction system also presents a high accident rate. Accordingly, industrialized building systems cannot claim to be safer than traditional ones. The different types of "on-site work" seem to be the main variable which would explain the accident rates recorded in industrialized construction systems. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. NRC perspective on extended on-site storage of low-level radioactive waste after 1993

    International Nuclear Information System (INIS)

    Remick, Forrest J.

    1992-01-01

    The Low-Level Radioactive Waste Policy Amendments Act of 1985 (LLRWPAA) requires that each State, which has not provided for disposal capacity by January 1, 1993, must take title and possession of the low-level radioactive wastes generated in the State. If the states do not take title and possession of the wastes, the rebates to which the states would have been entitled to would be returned to the waste generators. in considering the matter, the Commission solicited comments from States) low-level radioactive waste compacts, local governments, and the general public so that the public's views could be factored into the Commission's deliberations on this issue. This paper addresses the current status of NRC positions on the adequacy of the NRC's existing regulatory framework associated with the title transfer provisions of the LLRWPAA and the Commission's views on extended on-site storage of low-level radioactive wastes after the 1993 and 1996 milestones. (author)

  16. On-site comprehensive analysis of explosives using HPLC-UV-PAED

    Science.gov (United States)

    Marple, Ronita L.; LaCourse, William R.

    2004-03-01

    High-performance liquid chromatography with ultra violet and photo-assisted electrochemical detection (HPLC-UV-PAED) has been developed for the sensitive and selective detection of explosives in ground water and soil extracts. Fractionation and preconcentration of explosives is accomplished with on-line solid phase extraction (SPE), which minimizes sample pretreatment and enables faster and more accurate on-site assessment of a contaminated site. Detection limits are equivalent or superior (i.e., applicable, as it is capable of determining a wider range of organic nitro compounds. Soil samples are extracted using pressurized fluid extraction (PFE), and this technique is automatable, field-compatible, and environmentally friendly, adding to the overall efficiency of the methodology.

  17. Evaluation of gamma-spectrometry equipment for on-site inspection

    International Nuclear Information System (INIS)

    Burnett, J.L.; Milbrath, B.D.; Mueller, W.F.

    2017-01-01

    An On-site Inspection (OSI) is an important component of the verification regime of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), with the objective of gathering evidence of a possible Treaty violation. This includes the use of gamma-spectrometry equipment to identify 17 particulate radionuclides that are indicative of a nuclear explosion. This research provides an evaluation of high- (germanium), medium- (cadmium zinc telluride) and low-resolution (sodium iodide and lanthanum bromide) detectors using modelled radionuclide signatures from a nuclear explosion and Monte Carlo simulations of a detector response. The complex radionuclide signatures are shown to only be distinguishable using a high-resolution system for 1 week and 1 year post-detonation cases. (author)

  18. On-site inspection for the radionuclide observables of an underground nuclear explosion

    International Nuclear Information System (INIS)

    Burnett, J.L.

    2015-01-01

    Under the Comprehensive Nuclear-Test-Ban Treaty an on-site inspection (OSI) may be undertaken to identify signatures from a potential nuclear explosion. This includes the measurement of 17 particulate radionuclides ( 95 Zr, 95 Nb, 99 Mo, 99m Tc, 103 Ru, 106 Rh, 132 Te, 131 I, 132 I, 134 Cs, 137 Cs, 140 Ba, 140 La, 141 Ce, 144 Ce, 144 Pr, 147 Nd). This research provides an assessment of the potential to detect these radionuclides during an OSI within 1 week to 2 years after a nuclear explosion at two locations. A model has been developed that simulates the underground detonation of a 1 kT 235 U nuclear weapon with 1 % venting. This indicates a requirement to minimise the time since detonation with accurate determination of the test location. (author)

  19. User's manual for applicants proposing on-site burial of self-generated radioactive waste

    International Nuclear Information System (INIS)

    Tolbert, M.E.M.; Loretan, P.A.

    1987-01-01

    This document describes, for medical and research institutions as well as industrial generators of low-level radioactive waste, the NRC or state submittal requirements for authorizing the on-site burial of self-generated radioactive waste. An important part of completing the license application for operation justifying this alternative for waste disposal over other alternatives. Reasons that might be considered acceptable might include the need to dispose of large volumes of low activity waste that would otherwise take up valuable space in commercial sites; the ability to demonstrate that this method of disposal will result in reduced exposures to the public; the ability to show that the prohibitive costs of other methods of disposal would be detrimental to the progress of significant research which generates radioactive waste. 19 refs., 3 figs., 4 tabs

  20. Corrosion rate of steel in concrete - Evaluation of confinement techniques for on-site corrosion rate

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica; Elsener, Bernhard

    2009-01-01

    Earlier on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when different commercially available instruments are used. The different confinement techniques, rather than the different electrochemical techniques used in the instruments, are considered...... to be the main reason for the discrepancies. This paper presents a method for the quantitative assessment of confinement techniques based on monitoring the operation of the corrosion rate instrument and the current distribution between the electrode assembly on the concrete surface and a segmented reinforcement...... bar embedded in the concrete. The applicability of the method was demonstrated on two commercially available corrosion rate instruments based on different confinement techniques. The method provided an explanation of the differences in performance of the two instruments. Correlated measurements...

  1. Joint federal initiative for demonstration of on-site innovative technologies

    International Nuclear Information System (INIS)

    Marsh, J.; Munro, J.F.; McKinnon, C.; Coyle, G.J.

    1994-01-01

    The Federal Government needs to develop and implement new technologies to support its environmental and waste management programs. The incentive is threefold: First, new technologies are needed to accomplish many cleanup and waste management tasks. Second, the development and implementation of new technologies is expected to reduce significantly total cleanup costs. Third, the development of new environmental technologies can help secure national economic advantages by making U.S. industry more competitive in terms of global environmental markets. The Federal Advisory Committee to Develop On-Site Innovative Technologies (DOIT) initiative reinvents inter-governmental relations by stressing the solving of environmental problems through partnerships rather than through confrontation. This overview -- which is essentially a shortened and slightly modified version of the recent Coordinating Group Report to the DOIT Committee --describes the waste management challenges facing the Nation, discusses the innovative solutions offered by DOIT, outlines progress of the initiative to date, and identifies critical next steps

  2. Topological phases in the Haldane model with spin–spin on-site interactions

    Science.gov (United States)

    Rubio-García, A.; García-Ripoll, J. J.

    2018-04-01

    Ultracold atom experiments allow the study of topological insulators, such as the non-interacting Haldane model. In this work we study a generalization of the Haldane model with spin–spin on-site interactions that can be implemented on such experiments. We focus on measuring the winding number, a topological invariant, of the ground state, which we compute using a mean-field calculation that effectively captures long-range correlations and a matrix product state computation in a lattice with 64 sites. Our main result is that we show how the topological phases present in the non-interacting model survive until the interactions are comparable to the kinetic energy. We also demonstrate the accuracy of our mean-field approach in efficiently capturing long-range correlations. Based on state-of-the-art ultracold atom experiments, we propose an implementation of our model that can give information about the topological phases.

  3. Validation of on-site job-built guardrails with shoring jack as supports

    Directory of Open Access Journals (Sweden)

    Lan, A.

    2014-06-01

    Full Text Available To protect themselves against fall hazards in a slab-column frame, workers use the row of shoring jacks installed at 1 m from the edge as supports for on-site built guardrails. Inspectors of the Quebec Workers Compensation Board (Commission de la santé et de la sécurité du travail (CSST have expressed concern about the safety and compliance of these on-site built guardrails with the Quebec Safety Code for the Construction Industry (S-2.1, r.4. Some workers have also inquired if the shoring jack can be used as an anchor for a travel restraint system. The present study describes how an evaluation method and a test protocol have been used to verify if guardrails built on-site, with shoring jacks as supports, are safe and comply with the requirements of S-2.1, r.4 and if the shoring jack can be used as an anchor point for a travel restraint system. The results of the study show 1 guardrails built on site with shoring jacks as supports, are safe and comply with S-2.1, r.4 and 2 shoring jacks used as supports for guardrails must not be used as an anchor for a travel restraint system.Para la protección contra el peligro de caída en altura durante la ejecución de la estructura de un edificio, los trabajadores utilizan puntales acodalados a dos forjados y situados a 1 metro del borde de forjado como apoyo de las barandillas de seguridad. Inspectores de la Quebec Workers Compensation Board (Commision de la santé et de la sécurité du travail (CSST han expresado su preocupación por la seguridad y el cumplimiento de estos sistemas de protección en la construcción conforme al Código de Seguridad de Quebec para la industria de la construcción (S-2.1, R.6. Así mismo algunos trabajadores han mostrado su inquietud sobre la utilización de los puntales como sistemas para limitar el desplazamiento. El presente estudio describe un método de evaluación y un procedimiento de ensayo que se han utilizado para verificar si las barandillas de seguridad

  4. The protection of on-site personnel in the event of a radiological accident

    International Nuclear Information System (INIS)

    Morrey, M.; Simister, D.N.

    2003-01-01

    The National Radiological Protection Board (NPRB) is responsible in the UK for advising Government and other responsible bodies on the principles for responding to radiological emergencies. NRPB has published appropriate advice on the off-site protection of the public and on the protection of workers involved in taking mitigating actions to reduce the exposure of others. This paper puts forward a suggested framework for the protection of on-site personnel in the event of a radiological emergency which might include a criticality accident. This framework both dovetails with existing planning for the protection of members of the public off-site, and also takes account of specific differences between the situations on and off-site. (author)

  5. Revaluation of breast cytology with pathologist on-site of lesions with suspicious sonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Capalbo, Emanuela, E-mail: emanuelacapalbo@tiscalinet.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Sajadidehkordi, Farideh, E-mail: faridehit@yahoo.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Colombi, Claudio; Ticha, Vladimira; Moretti, Angela, E-mail: info.radiologia@sancarlo.mi.it [Dipartimento di Scienze Diagnostiche, UOC di Radiologia Diagnostica ed Interventistica, A.O San Carlo Borromeo. Via Pio II, 3, 20153 Milano (Italy); Peli, Michela, E-mail: peli.michela@gmail.com [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Cosentino, Maria, E-mail: maria-cosentino@tiscali.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Lovisatti, Maria, E-mail: marialovisatti@hotmail.com [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Berti, Elisabetta, E-mail: eliberti@hotmail.it [Dipartimento di Scienze Diagnostiche, UOC di Anatomia Patologica, A.O San Carlo Borromeo. Via Pio II, 3, Milano 20153 (Italy); Cariati, Maurizio, E-mail: info.radiologia@sancarlo.mi.it [Dipartimento di Scienze Diagnostiche, UOC di Radiologia Diagnostica ed Interventistica, A.O San Carlo Borromeo. Via Pio II, 3, 20153 Milano (Italy)

    2013-09-15

    Objective: Evaluating correlation estimation between diagnostic ultrasound (U.S.) of breast lesions and fine needle aspiration cytology (FNAC), and the correlation between cytology and histology (I) of these lesions undergo surgery. Materials and methods: In 2010 we performed 1589 ultrasound breast. We identified 210 suspicious lesions to be subjected to FNAC, which was performed with pathologist on site, and extemporaneous analysis of the sample to assess their appropriateness. We classified the lesions in 5 ultrasound (U) classes according to the criteria defined by Echographic BIRADS Lexicon. The results of cytology were classified in 5 classes (C) according to the guidelines of F.O.N.Ca.M. Then we evaluated the diagnostic correlation between U.S. and FNAC, and between FNAC and Histology. Results: The distribution of lesions in U classes was: 57U2, 55U3, 36U4 and 62U5. The diagnostic concordance between U and FNAC was 96.7%, with a sensitivity of 98%, specificity 93%, negative and positive predictive value respectively of 94.9% and 97.3%, and diagnostic accuracy of 96.6%. The 98 patients with C4-C5 lesions were subjected to surgery and the histology confirmed high-grade malignancy of lesions with a concordance of 99.7%. Conclusions: Having achieved high diagnostic concordance between U and FNAC, and then between FNAC and histology, we may say that the FNAC, less invasive and traumatic for the patient than needle biopsy (CB), may be still a valid method when performed with pathologist on-site to assess the adequacy of the sample taken.

  6. Recreational use in dispersed public lands measured using social media data and on-site counts.

    Science.gov (United States)

    Fisher, David M; Wood, Spencer A; White, Eric M; Blahna, Dale J; Lange, Sarah; Weinberg, Alex; Tomco, Michael; Lia, Emilia

    2018-09-15

    Outdoor recreation is one of many important benefits provided by public lands. Data on recreational use are critical for informing management of recreation resources, however, managers often lack actionable information on visitor use for large protected areas that lack controlled access points. The purpose of this study is to explore the potential for social media data (e.g., geotagged images shared on Flickr and trip reports shared on a hiking forum) to provide land managers with useful measures of recreational use to dispersed areas, and to provide lessons learned from comparing several more traditional counting methods. First, we measure daily and monthly visitation rates to individual trails within the Mount Baker-Snoqualmie National Forest (MBSNF) in western Washington. At 15 trailheads, we compare counts of hikers from infrared sensors, timelapse cameras, and manual on-site counts, to counts based on the number of shared geotagged images and trip reports from those locations. Second, we measure visitation rates to each National Forest System (NFS) unit across the US and compare annual measurements derived from the number of geotagged images to estimates from the US Forest Service National Visitor Use Monitoring Program. At both the NFS unit and the individual-trail scales, we found strong correlations between traditional measures of recreational use and measures based on user-generated content shared on the internet. For national forests in every region of the country, correlations between official Forest Service statistics and geotagged images ranged between 55% and 95%. For individual trails within the MBSNF, monthly visitor counts from on-site measurements were strongly correlated with counts from geotagged images (79%) and trip reports (91%). The convenient, cost-efficient and timely nature of collecting and analyzing user-generated data could allow land managers to monitor use over different seasons of the year and at sites and scales never previously

  7. On-site preparation of technetium-99m labeled human serum albumin for clinical application

    International Nuclear Information System (INIS)

    Wang Yuhfeng; Chuang Meihua; Cham Thauming; Chung Meiing; Chiu Jainnshiun

    2007-01-01

    Technetium-99m labeled human serum albumin (Tc-99m HSA) is an important radiopharmaceutical for clinical applications, such as cardiac function tests or protein-losing gastroenteropathy assessment. However, because of transfusion-induced infectious diseases, the safety of serum products is a serious concern. In this context, serum products acquired from patients themselves are the most ideal tracer. However, the development of rapid separation and easy clinical labeling methods is not yet well established. Under such situation, products from the same ethnic group or country are now recommended by the World Health Organization as an alternative preparation. This article describes the on-site preparation of Tc-99m HSA from locally supplied serum products. Different formulations were prepared and the labeling efficiency and stability were examined. Radio-labeling efficiencies were more than 90% in all preparation protocols, except for one that omitted the stannous solution. The most cost-effective protocol contained HSA 0.1 mg, treated with stannous fluoride 0.2 mg, and mixed with Tc-99m pertechnetate 30 mCi. A biodistribution study was performed in rats using a gamma camera immediately after intravenous administration of radiolabeled HSA. Tissue/organ uptake was obtained by measuring the radioactivity in organs after sacrificing the rats at timed intervals. The biologic half-life was about 32 min, determined from sequential venous blood collections. These data indicate that our preparation of Tc-99m HSA is useful and potentially applicable clinically. In addition, this on-site preparation provides the possibility of labeling a patient's own serum for subsequent clinical application. (author)

  8. On-site and off-site emergency planning at Cekmece Nuclear Research and Training Centre

    International Nuclear Information System (INIS)

    Soyberk, O.A.

    1986-01-01

    An emergency plan was prepared for minimizing the consequences of any unforeseen radiation accident in Cekmece Nuclear Research and Training Centre (CNAEM) in Istanbul, Turkey. CNAEM is situated near Kucukcekmece Lake, which is about 30 km to the west of Istanbul. It includes two pool-type research reactors of 1 MW(th) and 5 MW(th). The population in the nearest inhabited areas varies from 1000 to 50,000. Accidents are classified, according to their severity, into three categories at CNAEM: (a) local emergency, (b) on-site emergency, (c) off-site emergency. During local emergency situations evacuation is not necessary. An on-site emergency situation requires the evacuation of personnel from the plant. Personnel hearing the emergency alarm should move directly to the preselected place as soon as possible. An off-site emergency is any accident that leads to widespread contamination outside the boundary. In this situation the Turkish Atomic Energy Authority and governmental authorities are notified immediately. The emergency organization group consists of: (a) Plant Superintendent, (b) Emergency Director, (c) Reactor Supervisor, (d) Senior Health Physicist, (e) Reactor Shift Operator, (f) Health Physicists. The administration building will be used as the Emergency Control Centre. The emergency teams working under the direction of the Emergency Director consist of: (a) Health Physics, (b) Fire and Rescue, (c) First Aid and Decontamination, (d) Transportation, (e) Security and Patrol. The emergency situation is evaluated in three phases at CNAEM. The first phase is the first few hours after the beginning of the accident. The second phase is between 8-10 hours or more following the first phase. The third phase is the recovery phase. The integrated doses over periods of two hours and two days are calculated according to the situation of the core, i.e. total or partial melting, and weather conditions. The results of the calculated parameters can be adapted to possible

  9. Exertional heat illness incidence and on-site medical team preparedness in warm weather.

    Science.gov (United States)

    Hosokawa, Yuri; Adams, William M; Belval, Luke N; Davis, Robert J; Huggins, Robert A; Jardine, John F; Katch, Rachel K; Stearns, Rebecca L; Casa, Douglas J

    2018-03-29

    To investigate the influence of estimated wet bulb globe temperature (WBGT) and the International Institute of Race Medicine (IIRM) activity modification guidelines on the incidence of exertional heat stroke (EHS) and heat exhaustion (HEx) and the ability of an on-site medical team to treat those afflicted. Medical records of EHS and HEx patients over a 17-year period from the New Balance Falmouth Road Race were examined. Climatologic data from nearby weather stations were obtained to calculate WBGT with the Australian Bureau of Meteorology (WBGT A ) and Liljegren (WBGT L ) models. Incidence rate (IR) of EHS, HEx, and combined total of EHS and HEx (COM) were calculated, and linear regression analyses were performed to assess the relationship between IR and WBGT A or WBGT L . One-way ANOVA was performed to compare differences in EHS, HEx, and COM incidence to four alert levels in the IIRM guidelines. Incidence of EHS, HEx, and COM was 2.12, 0.98, and 3.10 cases per 1000 finishers. WBGT A explained 48, 4, and 46% of the variance in EHS, HEx, and COM IR; WBGT L explained 63, 13, and 69% of the variance in EHS, HEx, and COM IR. Main effect of WBGT A and WBGT L on the alert levels were observed in EHS and COM IR (p < 0.05). The cumulative number of EHS patients treated did not exceed the number of cold water immersion tubs available to treat them. EHS IR increased as WBGT and IIRM alert level increased, indicating the need for appropriate risk mitigation strategies and on-site medical treatment.

  10. An overview of the on-site inspection measurements from the non-proliferation experiment

    Energy Technology Data Exchange (ETDEWEB)

    Zucca, J.J. [Lawrence Livermore National Lab., CA (United States)

    1994-12-31

    An on-site inspection (OSI) is an in-person visit to site to collect data and examine evidence in order to determine the source of an ambiguous event detected via remote monitoring systems or other measures. Its purpose is to determine whether the treaty has been violated, to deter violations, and to build confidence. At the time of this writing, it is anticipated that the Comprehensive Test Ban Treaty (CTBT) being developed in the Conference on Disarmament will contain OSI provisions. In an era of testing moratoria, the Non-Proliferation Experiment (NPE) provided a unique opportunity to investigate candidate OSI techniques. On site inspections could occur in three different contexts: after-the-fact inspections based on information from remote monitoring systems; inspections prior to, during, and after large declared chemical explosions (e.g., a large mining explosion); continuous monitoring inspections with unattended sensors at certain agreed-upon sites (e.g., previous test sites). OSI monitoring techniques need to be designed to detect the phenomena and residual effects of nuclear explosions. In the underground case, the primary effects of interest for OSI are the electromagnetic pulse, shock waves, aftershocks, radioactive gas, rubble zone, and apical void. These effects are well known and the basic techniques for their detection well established. We designed our measurement program for the NPE to answer specific issues about these detection technologies. Our measurement program includes the following: zerotime electromagnetic measurements; seismic aftershock survey; before and after electrical soundings; gas tracers introduced into the explosive; before and after multispectral overhead imagery from low-flying aircraft; before and after geological surveys.

  11. Dynamic analysis of the PEC fast reactor vessel: On-site tests and mathematical models

    International Nuclear Information System (INIS)

    Zola, M.; Martelli, A.; Masoni, P.; Scandola, G.

    1988-01-01

    This paper presents the main features and results of the on-site dynamic tests and the related numerical analyses carried out for the PEC reactor vessel. The purpose is to provide an example of on-site testing of large components, stressing the problems encountered during the experiments, as well as in the processing phase of the test results and for the comparisons between calculations and measurements. Tests, performed by ISMES on behalf of ENEA, allowed the dynamic response of the empty vessel to be measured, thus providing data for the verification of the numerical models of the vessel supporting structure adopted in the PEC reactor-block seismic analysis. An axisymmetric model of the vessel, implemented in the NOVAX code, had been developed in the framework of the detailed numerical studies performed by NOVATOME (again on behalf of ENEA), to check the beam schematization with fluid added mass model adopted by ANSALDO in SAP-IV and ANSYS for the reactor-block design calculations. Furthermore, a numerical model, describing vessel supporting structure in detail, was also developed by ANSALDO and implemented in the SAP-IV code. The test conditions were analysed by use of these and the design models. Comparisons between calculations and measurements showed particularly good agreement with regard to first natural frequency of the vessel and rocking stiffness of the vessel supporting structure, i.e. those parameters on which vessel seismic amplification mainly depends: this demonstrated the adequacy of the design analysis to correctly calculate the seismic motion at the PEC core diagrid. (author). 5 refs, 23 figs, 4 tabs

  12. Dynamic analysis of the PEC fast reactor vessel: on-site tests and mathematical models

    International Nuclear Information System (INIS)

    Zola, Maurizio; Martelli, Alessandro; Maresca, Giuseppe; Masoni, Paolo; Scandola, Giani; Descleves, Pierre

    1988-01-01

    This paper presents the main features and results of the on-site dynamic tests and the related numerical analysis carried out for the PEC reactor vessel. The purpose is to provide an example of on-site testing of large components, stressing the problems encountered during the experiments, as well as in the processing phase of the test results and for the comparisons between calculations and measurements. Tests, performed by ISMES on behalf of ENEA, allowed the dynamic response of the empty vessel to be measured, thus providing data for the verification of the numerical models of the vessel supporting structure adopted in the PEC reactor-block seismic analysis. An axisymmetric model of the vessel, implemented in the vessel, implemented in the NOVAK code, had been developed in the framework of the detailed numerical studies performed by NOVATOME (again on behalf of ENEA), to check the beam schematization with fluid added mass model adopted by ANSALDO in SAP-IV and ANSYS for the reactor-block design calculations. Furthermore, a numerical model, describing vessel supporting structure in detail, was also developed by ANSALDO and implemented in the SAP-IV code. The test conditions were analysed by use of these and the design models. Comparisons between calculations and measurements showed particularly good agreement with regard to first natural frequency of the vessel and rocking stiffness of the vessel supporting structure, i.e. those parameters on which vessel seismic amplification mainly depends: this demonstrated the adequacy of the design analysis to correctly calculate the seismic motion at the PEC core diagrid. (author)

  13. Exertional heat illness incidence and on-site medical team preparedness in warm weather

    Science.gov (United States)

    Hosokawa, Yuri; Adams, William M.; Belval, Luke N.; Davis, Robert J.; Huggins, Robert A.; Jardine, John F.; Katch, Rachel K.; Stearns, Rebecca L.; Casa, Douglas J.

    2018-03-01

    To investigate the influence of estimated wet bulb globe temperature (WBGT) and the International Institute of Race Medicine (IIRM) activity modification guidelines on the incidence of exertional heat stroke (EHS) and heat exhaustion (HEx) and the ability of an on-site medical team to treat those afflicted. Medical records of EHS and HEx patients over a 17-year period from the New Balance Falmouth Road Race were examined. Climatologic data from nearby weather stations were obtained to calculate WBGT with the Australian Bureau of Meteorology (WBGTA) and Liljegren (WBGTL) models. Incidence rate (IR) of EHS, HEx, and combined total of EHS and HEx (COM) were calculated, and linear regression analyses were performed to assess the relationship between IR and WBGTA or WBGTL. One-way ANOVA was performed to compare differences in EHS, HEx, and COM incidence to four alert levels in the IIRM guidelines. Incidence of EHS, HEx, and COM was 2.12, 0.98, and 3.10 cases per 1000 finishers. WBGTA explained 48, 4, and 46% of the variance in EHS, HEx, and COM IR; WBGTL explained 63, 13, and 69% of the variance in EHS, HEx, and COM IR. Main effect of WBGTA and WBGTL on the alert levels were observed in EHS and COM IR (p < 0.05). The cumulative number of EHS patients treated did not exceed the number of cold water immersion tubs available to treat them. EHS IR increased as WBGT and IIRM alert level increased, indicating the need for appropriate risk mitigation strategies and on-site medical treatment.

  14. NSTX Electrical Power Systems

    International Nuclear Information System (INIS)

    A. Ilic; E. Baker; R. Hatcher; S. Ramakrishnan; et al

    1999-01-01

    The National Spherical Torus Experiment (NSTX) has been designed and installed in the existing facilities at Princeton Plasma Physic Laboratory (PPPL). Most of the hardware, plant facilities, auxiliary sub-systems, and power systems originally used for the Tokamak Fusion Test Reactor (TFTR) have been used with suitable modifications to reflect NSTX needs. The design of the NSTX electrical power system was tailored to suit the available infrastructure and electrical equipment on site. Components were analyzed to verify their suitability for use in NSTX. The total number of circuits and the location of the NSTX device drove the major changes in the Power system hardware. The NSTX has eleven (11) circuits to be fed as compared to the basic three power loops for TFTR. This required changes in cabling to insure that each cable tray system has the positive and negative leg of cables in the same tray. Also additional power cabling had to be installed to the new location. The hardware had to b e modified to address the need for eleven power loops. Power converters had to be reconnected and controlled in anti-parallel mode for the Ohmic heating and two of the Poloidal Field circuits. The circuit for the Coaxial Helicity Injection (CHI) System had to be carefully developed to meet this special application. Additional Protection devices were designed and installed for the magnet coils and the CHI. The thrust was to making the changes in the most cost-effective manner without compromising technical requirements. This paper describes the changes and addition to the Electrical Power System components for the NSTX magnet systems

  15. Facile on-site detection of substituted aromatic pollutants in water using thin layer chromatography combined with surface-enhanced Raman spectroscopy.

    Science.gov (United States)

    Li, Dawei; Qu, Lulu; Zhai, Wenlei; Xue, Jinqun; Fossey, John S; Long, Yitao

    2011-05-01

    A novel facile method for on-site detection of substituted aromatic pollutants in water using thin layer chromatography (TLC) combined with surface-enhanced Raman spectroscopy (SERS) was explored. Various substituted aromatics in polluted water were separated by a convenient TLC protocol and then detected using a portable Raman spectrometer with the prepared silver colloids serving as SERS-active substrates. The effects of operating conditions on detection efficacy were evaluated, and the application of TLC-SERS to on-site detection of artificial and real-life samples of aromatics/polluted water was systematically investigated. It was shown that commercially available Si 60-F(254) TLC plates were suitable for separation and displayed low SERS background and good separation efficiency, 2 mM silver colloids, 20 mM NaCl (working as aggregating agent), 40 mW laser power, and 50 s intergration time were appropriate for the detection regime. Furthermore, qualitative and quantitative detection of most of substituted aromatic pollutants was found to be readily accomplished using the developed TLC-SERS technique, which compared well with GC-MS in terms of identification ability and detection accuracy, and a limit of detection (LOD) less than 0.2 ppm (even at ppb level for some analytes) could be achieved under optimal conditions. The results reveal that the presented convenient method could be used for the effective separation and detection of the substituted aromatic pollutants of water on site, thus reducing possible influences of sample transportation and contamination while shortening the overall analysis time for emergency and routine monitoring of the substituted aromatics/polluted water.

  16. 28 CFR Appendix C to Part 79 - Radiation Exposure Compensation Act Offset Worksheet-On Site Participants

    Science.gov (United States)

    2010-07-01

    ..., Column 4 “Actuarial Present Value”of past payments = $0.00 NET AMOUNT OWED CLAIMANT ($75,000 less APV... Compensation Act Offset Worksheet—On Site Participants [Present CPI = 185.20] VA paymentsyear Payment Indicated...

  17. 77 FR 14832 - Plumchoice, Inc., Including On-Site Leased Workers From Balance Staffing, Insight Global Staffing...

    Science.gov (United States)

    2012-03-13

    ...., Including On-Site Leased Workers From Balance Staffing, Insight Global Staffing, and Technisource..., Insight Global Staffing, and Technisource, Scarborough, Maine. The workers are engaged in activities... leased workers from Balance Staffing, Insight Global Staffing, and Technisource, Scarborough, Maine, who...

  18. Temperature-dependent thermal conductivities of one-dimensional nonlinear Klein-Gordon lattices with a soft on-site potential.

    Science.gov (United States)

    Yang, Linlin; Li, Nianbei; Li, Baowen

    2014-12-01

    The temperature-dependent thermal conductivities of one-dimensional nonlinear Klein-Gordon lattices with soft on-site potential (soft-KG) are investigated systematically. Similarly to the previously studied hard-KG lattices, the existence of renormalized phonons is also confirmed in soft-KG lattices. In particular, the temperature dependence of the renormalized phonon frequency predicted by a classical field theory is verified by detailed numerical simulations. However, the thermal conductivities of soft-KG lattices exhibit the opposite trend in temperature dependence in comparison with those of hard-KG lattices. The interesting thing is that the temperature-dependent thermal conductivities of both soft- and hard-KG lattices can be interpreted in the same framework of effective phonon theory. According to the effective phonon theory, the exponents of the power-law dependence of the thermal conductivities as a function of temperature are only determined by the exponents of the soft or hard on-site potentials. These theoretical predictions are consistently verified very well by extensive numerical simulations.

  19. Temperature-dependent thermal conductivities of one-dimensional nonlinear Klein-Gordon lattices with a soft on-site potential

    Science.gov (United States)

    Yang, Linlin; Li, Nianbei; Li, Baowen

    2014-12-01

    The temperature-dependent thermal conductivities of one-dimensional nonlinear Klein-Gordon lattices with soft on-site potential (soft-KG) are investigated systematically. Similarly to the previously studied hard-KG lattices, the existence of renormalized phonons is also confirmed in soft-KG lattices. In particular, the temperature dependence of the renormalized phonon frequency predicted by a classical field theory is verified by detailed numerical simulations. However, the thermal conductivities of soft-KG lattices exhibit the opposite trend in temperature dependence in comparison with those of hard-KG lattices. The interesting thing is that the temperature-dependent thermal conductivities of both soft- and hard-KG lattices can be interpreted in the same framework of effective phonon theory. According to the effective phonon theory, the exponents of the power-law dependence of the thermal conductivities as a function of temperature are only determined by the exponents of the soft or hard on-site potentials. These theoretical predictions are consistently verified very well by extensive numerical simulations.

  20. Superconducting correlations in the one-band Hubbard model with intermediate on-site and weak attractive intersite interactions

    International Nuclear Information System (INIS)

    Jain, K.P.; Ramakumar, R.; Chancey, C.C.

    1990-01-01

    In this paper, we analyze a simple extended Hubbard model with an intermediate on-site interaction (both repulsive and attractive) and a weak intersite attractive interaction. Following Hubbard decoupling approximations and introducing Hubbard subband operators, we obtain a generalized gap function for singlet s-wave pairing that explicitly depends on the Hubbard subband energies. For the on-site repulsive-interaction case, we find that the superconductivity is not destroyed in the intermediate-interaction regime, contrary to the prediction of a Hartree-Fock mean-field treatment. The essential consequence of the on-site repulsion is the formation of the Hubbard subbands separated by the Mott-Hubbard gap, and it is within these subbands that pairing induced by the intersite interaction occurs. For the attractive on-site interaction case, the on-site pairing amplitude is found to be proportional to the bandwidth, and the gap function has contributions from both on-site and intersite pairing. The relevance of the model to high-temperature superconductivity is discussed

  1. Millstone nuclear power plant emergency system assessment

    International Nuclear Information System (INIS)

    Akhmad Khusyairi

    2011-01-01

    U.S.NRC determined an obligation to build a nuclear power plant emergency response organization for both on-site and off-site. Millstone Nuclear Power Plants have 3 nuclear reactors and 2 of 3 still in commercial operation. Reactor unit 1, BWR type has been permanently shut down in 1998, while the two others, units 2 and 3 obtain the extended operating license respectively until 2035 and 2045. As a nuclear installation has the high potential radiological impact, Millstone nuclear power plant emergency response organization must establish both on-site or off-site. Emergency response organization that is formed must involve several state agencies, both state agencies and municipality. They have specific duties and functions in a state of emergency, so that protective measures can be undertaken in accordance with the community that has been planned. Meanwhile, NRC conduct their own independent assessment of nuclear power plant emergencies. (author)

  2. On-site investigations of hydrocarbon contaminated soil by the Pollut-Eval methodology

    International Nuclear Information System (INIS)

    Benoit, Y.; Prigent, S.; Haeseler, F.

    2005-01-01

    lack of sample pre-treatment and the adaptation of a cooled auto-sampler, short time analysis suited for light petroleum pollutant such as gasoline and kerosene. The simple protocol applied to the soil appeared rapidly suitable for keeping the track of depollution process efficiency. During its qualification, the analyser has been involved in rehabilitation process evaluation by analysing various contaminated soils before and after clean-up treatment. From 1999, IFP was frequently asked for on-site diagnosis involving Pollut-Eval methodology. So, IFP installed this lab equipment in a mobile van in order to qualify the methodology through real time and on-site diagnosis. In addition to the qualification program, the aim of the project was also to identify the analytical parameters available in the method and sufficient for field contaminated soil characterisation. During 2 years, all over France, IFP, Gester and Vinci Technologies gathered their effort to ensure 10-site diagnosis. The variety of pollutants encountered has enriched a data base that has been included in a user guide. The gathered experience ended by the design of a compact apparatus dedicated to field analyses. Its small size and weight (less than 20 kg) was designed to perform on-site and autonomous characterisations. (authors)

  3. Pragmatic power

    CERN Document Server

    Eccles, William

    2008-01-01

    Pragmatic Power is focused on just three aspects of the AC electrical power system that supplies and moves the vast majority of electrical energy nearly everywhere in the world: three-phase power systems, transformers, and induction motors. The reader needs to have had an introduction to electrical circuits and AC power, although the text begins with a review of the basics of AC power. Balanced three-phase systems are studied by developing their single-phase equivalents. The study includes a look at how the cost of ""power"" is affected by reactive power and power factor. Transformers are cons

  4. [On-site evaluation of raw milk qualities by portable Vis/NIR transmittance technique].

    Science.gov (United States)

    Wang, Jia-Hua; Zhang, Xiao-Wei; Wang, Jun; Han, Dong-Hai

    2014-10-01

    To ensure the material safety of dairy products, visible (Vis)/near infrared (NIR) spectroscopy combined with che- mometrics methods was used to develop models for fat, protein, dry matter (DM) and lactose on-site evaluation. A total of 88 raw milk samples were collected from individual livestocks in different years. The spectral of raw milk were measured by a porta- ble Vis/NIR spectrometer with diffused transmittance accessory. To remove the scatter effect and baseline drift, the diffused transmittance spectra were preprocessed by 2nd order derivative with Savitsky-Golay (polynomial order 2, data point 25). Changeable size moving window partial least squares (CSMWPLS) and genetic algorithms partial least squares (GAPLS) meth- ods were suggested to select informative regions for PLS calibration. The PLS and multiple linear regression (MLR) methods were used to develop models for predicting quality index of raw milk. The prediction performance of CSMWPLS models were similar to GAPLS models for fat, protein, DM and lactose evaluation, the root mean standard errors of prediction (RMSEP) were 0.115 6/0.103 3, 0.096 2/0.113 7, 0.201 3/0.123 7 and 0.077 4/0.066 8, and the relative standard deviations of prediction (RPD) were 8.99/10.06, 3.53/2.99, 5.76/9.38 and 1.81/2.10, respectively. Meanwhile, the MLR models were also cal- ibrated with 8, 10, 9 and 7 variables for fat, protein, DM and lactose, respectively. The prediction performance of MLR models was better than or close to PLS models. The MLR models to predict fat, protein, DM and lactose yielded the RMSEP of 0.107 0, 0.093 0, 0.136 0 and 0.065 8, and the RPD of 9.72, 3.66, 8.53 and 2.13, respectively. The results demonstrated the usefulness of Vis/NIR spectra combined with multivariate calibration methods as an objective and rapid method for the quality evaluation of complicated raw milks. And the results obtained also highlight the potential of portable Vis/NIR instruments for on-site assessing quality indexes of

  5. Studies on site characterization methodologies for high level radioactive waste disposal

    International Nuclear Information System (INIS)

    Wang Ju; Guo Yonghai; Chen Weiming

    2008-01-01

    This paper presents the final achievement of the project 'Studies of Site-specific Geological Environment for High Level Waste Disposal and Performance Assessment Methodology, Part Ⅰ: Studies on Site Characterization Methodologies for High Level Radioactive Waste Disposal', which is a 'Key Scientific and Technological Pre-Research Project for National Defense' during 2001-2005. The study area is Beishan area, Gansu Province, NW China--the most potential site for China's underground research laboratory and high level radioactive waste repository. The boreholes BS01, BS2, BS03 and BS04 drilled in fractured granite media in Beishan are used to conduct comprehensive studies on site characterization methodologies, including: bore hole drilling method, in situ measurement methods of hydrogeological parameters, underground water sampling technology, hydrogeochemical logging method, geo-stress measurement method, acoustic borehole televiewer measurement method, borehole radar measurement method, fault stability evaluation methods and rock joint evaluation method. The execution of the project has resulted in the establishment of an 'Integrated Methodological System for Site Characterization in Granite Site for High Level Radioactive Waste Repository' and the 8 key methodologies for site characterization: bore hole drilling method with minimum disturbance to rock mass, measurement method for hydrogeological parameters of fracture granite mass, in situ groundwater sampling methods from bore holes in fractured granite mass, fracture measurement methods by borehole televiewer and bore radar system, hydrogeochemical logging, low permeability measurement methods, geophysical methods for rock mass evaluation, modeling methods for rock joints. Those methods are comprehensive, advanced, innovative, practical, reliable and of high accuracy. The comprehensive utilization of those methods in granite mass will help to obtain systematic parameters of

  6. On-Site Fecal Sludge Treatment with the Anaerobic Digestion Pasteurization Latrine.

    Science.gov (United States)

    Forbis-Stokes, Aaron A; O'Meara, Patrick F; Mugo, Wangare; Simiyu, Gelas M; Deshusses, Marc A

    2016-11-01

    The Anaerobic Digestion Pasteurization Latrine (ADPL) is a self-contained and energy neutral on-site sanitation system using anaerobic digestion of fecal sludge to generate biogas and then uses the biogas to pasteurize the digester effluent at 65-75°C to produce a safe effluent that can be reused locally as a fertilizer. Two ADPL systems were installed on residential plots with 17 and 35 residents in a peri-urban area outside of Eldoret, Kenya. Each system comprised three toilets built above a floating dome digester and one heat pasteurization system to sanitize the digested effluent. ADPLs are simple systems, with no moving parts and relying on gravity-induced flows. Adoption at the two sites was successful, and residents reported that the systems had little to no odor or flies. ADPLs were monitored for biogas production and temperatures in the pasteurization system. ADPLs serving 17 and 35 residents produced on average 16 and 11 L biogas /person/day (maximum of 20 and 15 L biogas /p/d), respectively. The temperature in the sterilization system was greater than 65°C on 58% and 87% of sampling days during the most stable period of operation. Treated effluent was analyzed periodically for chemical oxygen demand (COD), biochemical oxygen demand (BOD), total ammonia nitrogen (TAN), pH, and fecal coliform (FC). On average, the effluent at the two locations contained 4,540 and 6,450 mg COD/L (an 85% or 89% reduction of the estimated input), 2,050 and 3,970 mg BOD/L, and 2,420 and 4,760 mg NH 3 -N, respectively, and greater than 5 log reductions of FC (nondetectable) in the sterilization tank. Results from this field study show that anaerobic digestion of minimally diluted fecal sludge can provide enough energy to pasteurize digester effluent and that the ADPL may be a suitable option for on-site fecal sludge treatment.

  7. On-Site Fecal Sludge Treatment with the Anaerobic Digestion Pasteurization Latrine

    Science.gov (United States)

    Forbis-Stokes, Aaron A.; O'Meara, Patrick F.; Mugo, Wangare; Simiyu, Gelas M.; Deshusses, Marc A.

    2016-01-01

    Abstract The Anaerobic Digestion Pasteurization Latrine (ADPL) is a self-contained and energy neutral on-site sanitation system using anaerobic digestion of fecal sludge to generate biogas and then uses the biogas to pasteurize the digester effluent at 65–75°C to produce a safe effluent that can be reused locally as a fertilizer. Two ADPL systems were installed on residential plots with 17 and 35 residents in a peri-urban area outside of Eldoret, Kenya. Each system comprised three toilets built above a floating dome digester and one heat pasteurization system to sanitize the digested effluent. ADPLs are simple systems, with no moving parts and relying on gravity-induced flows. Adoption at the two sites was successful, and residents reported that the systems had little to no odor or flies. ADPLs were monitored for biogas production and temperatures in the pasteurization system. ADPLs serving 17 and 35 residents produced on average 16 and 11 Lbiogas/person/day (maximum of 20 and 15 Lbiogas/p/d), respectively. The temperature in the sterilization system was greater than 65°C on 58% and 87% of sampling days during the most stable period of operation. Treated effluent was analyzed periodically for chemical oxygen demand (COD), biochemical oxygen demand (BOD), total ammonia nitrogen (TAN), pH, and fecal coliform (FC). On average, the effluent at the two locations contained 4,540 and 6,450 mg COD/L (an 85% or 89% reduction of the estimated input), 2,050 and 3,970 mg BOD/L, and 2,420 and 4,760 mg NH3-N, respectively, and greater than 5 log reductions of FC (nondetectable) in the sterilization tank. Results from this field study show that anaerobic digestion of minimally diluted fecal sludge can provide enough energy to pasteurize digester effluent and that the ADPL may be a suitable option for on-site fecal sludge treatment. PMID:27924135

  8. A More Sustainable Way for Producing RC Sandwich Panels On-Site and in Developing Countries

    Directory of Open Access Journals (Sweden)

    Lorenzo Graziani

    2017-03-01

    Full Text Available The purpose of this work is to assess if traditionally used welded connectors for joining the two skins of reinforced concrete (RC sandwich panels, used as structural walls and horizontal structural elements, can be substituted with bent ones. In this way, the scope of the effort is to reduce drastically the energy required during manufacturing, thus having a much more sustainable building product. Wire mesh on site production, in fact, requires a large amount of energy for the welding process, as stated by several Environmental Product Declaration (EPD. In addition, the production of sandwich panels with bent connectors requires a low level of automation and no qualified labor allowing the diffusion in developing countries. The procedures used to execute the work were both experimental and numerical. Structural performances were examined by testing full-scale sandwich panels under (axial and eccentric compression and flexural loads. Additionally, a Finite Element (FE study was developed to investigate and to optimize the dimension of welded mesh and the number of connectors. The major findings show that it is possible to substitute welded connectors with bent ones without compromising the structural performance of the tested RC sandwich panels, thus having a more sustainable way for producing these last ones.

  9. Does wine glass size influence sales for on-site consumption? A multiple treatment reversal design

    Directory of Open Access Journals (Sweden)

    Rachel Pechey

    2016-06-01

    Full Text Available Abstract Background Wine glass size can influence both perceptions of portion size and the amount poured, but its impact upon purchasing and consumption is unknown. This study aimed to examine the impact of wine glass size on wine sales for on-site consumption, keeping portion size constant. Methods In one establishment (with separate bar and restaurant areas in Cambridge, England, wine glass size (Standard; Larger; Smaller was changed over eight fortnightly periods. The bar and restaurant differ in wine sales by the glass vs. by the bottle (93 % vs. 63 % by the glass respectively. Results Daily wine volume purchased was 9.4 % (95 % CI: 1.9, 17.5 higher when sold in larger compared to standard-sized glasses. This effect seemed principally driven by sales in the bar area (bar: 14.4 % [3.3, 26.7]; restaurant: 8.2 % [−2.5, 20.1]. Findings were inconclusive as to whether sales were different with smaller vs. standard-sized glasses. Conclusions The size of glasses in which wine is sold, keeping the portion size constant, can affect consumption, with larger glasses increasing consumption. The hypothesised mechanisms for these differential effects need to be tested in a replication study. If replicated, policy implications could include considering glass size amongst alcohol licensing requirements. Trial registration ISRCTN registry: ISRCTN12018175 . Registered 12th May 2015.

  10. Stretchable Tattoo-Like Heater with On-Site Temperature Feedback Control

    Directory of Open Access Journals (Sweden)

    Andrew Stier

    2018-04-01

    Full Text Available Wearable tissue heaters can play many important roles in the medical field. They may be used for heat therapy, perioperative warming and controlled transdermal drug delivery, among other applications. State-of-the-art heaters are too bulky, rigid, or difficult to control to be able to maintain long-term wearability and safety. Recently, there has been progress in the development of stretchable heaters that may be attached directly to the skin surface, but they often use expensive materials or processes and take significant time to fabricate. Moreover, they lack continuously active, on-site, unobstructive temperature feedback control, which is critical for accommodating the dynamic temperatures required for most medical applications. We have developed, fabricated and tested a cost-effective, large area, ultra-thin and ultra-soft tattoo-like heater that has autonomous proportional-integral-derivative (PID temperature control. The device comprises a stretchable aluminum heater and a stretchable gold resistance temperature detector (RTD on a soft medical tape as fabricated using the cost and time effective “cut-and-paste” method. It can be noninvasively laminated onto human skin and can follow skin deformation during flexure without imposing any constraint. We demonstrate the device’s ability to maintain a target temperature typical of medical uses over extended durations of time and to accurately adjust to a new set point in process. The cost of the device is low enough to justify disposable use.

  11. On-Site Decontamination System for Liquid Low Level Radioactive Waste - 13010

    Energy Technology Data Exchange (ETDEWEB)

    OSMANLIOGLU, Ahmet Erdal [Cekmece Nuclear Research and Training Center, Kucukcekmece Istanbul (Turkey)

    2013-07-01

    This study is based on an evaluation of purification methods for liquid low-level radioactive waste (LLLW) by using natural zeolite. Generally the volume of liquid low-level waste is relatively large and the specific activity is rather low when compared to other radioactive waste types. In this study, a pilot scale column was used with natural zeolite as an ion exchanger media. Decontamination and minimization of LLLW especially at the generation site decrease operational cost in waste management operations. Portable pilot scale column was constructed for decontamination of LLW on site. Effect of temperature on the radionuclide adsorption of the zeolite was determined to optimize the waste solution temperature for the plant scale operations. In addition, effect of pH on the radionuclide uptake of the zeolite column was determined to optimize the waste solution pH for the plant scale operations. The advantages of this method used for the processing of LLLW are discussed in this paper. (authors)

  12. Assessment of On-Site Treatment Process of Institutional Building’s Wastewater

    Directory of Open Access Journals (Sweden)

    Motasem N. Saidan

    2018-03-01

    Full Text Available This study is conducted to investigate the characteristics of outflow wastewater of the 1 m3 on-site wastewater treatment unit on the basis of the testing and measurement data of the samples that were taken during the study monitored period (August 2017 to January 2018. For this purpose, samples were taken on a weekly basis from the treated wastewater effluent and five quality parameters (biochemical oxygen demand (BOD, chemical oxygen demand (COD, total suspended solids (TSS, pH, E-coli counts were monitored and measured. The average values of the five parameters were compared with the Jordanian standard maximum values, and water reuse in irrigation of plants classifications have been assessed and investigated. Average values of BOD, COD, TSS, pH, and E-coli in treated wastewater were 11 mg/L, 104 mg/L, 15 mg/L, 7.51, and 387 counts, respectively. The installation of in-line ultraviolet (UV unit in recirculating delivery system played a vital role in the reduction of counts far below the permissible maximum level (1000 counts. Based on national and international standards and criteria, results showed that the treated wastewater is suitable for the irrigation of two classifications of plants: (i Fruit trees, road-green sides outside cities, and green landscape; (ii Crops, commercial crops, and forest trees. Hence, such very low water flow rate treatment system can be utilized in refugees’ camps and water scarce residential areas in Jordan.

  13. Testing in support of on-site storage of residues in the Pipe Overpack Container

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Bobbe, J.G.; Arviso, M.

    1997-02-01

    The disposition of the large back-log of plutonium residues at the Rocky Flats Environmental Technology Site (Rocky Flats) will require interim storage and subsequent shipment to a waste repository. Current plans call for disposal at the Waste Isolation Pilot Plant (WIPP) and the transportation to WIPP in the TRUPACT-II. The transportation phase will require the residues to be packaged in a container that is more robust than a standard 55-gallon waste drum. Rocky Flats has designed the Pipe Overpack Container to meet this need. It is desirable to use this same waste packaging for interim on-site storage in non-hardened buildings. To meet the safety concerns for this storage the Pipe Overpack Container has been subjected to a series of tests at Sandia National Laboratories in Albuquerque, New Mexico. In addition to the tests required to qualify the Pipe Overpack Container as a waste container for shipment in the TRUPACT-II several tests were performed solely for the purpose of qualifying the container for interim storage. This report will describe these tests and the packages response to the tests. 12 figs., 3 tabs

  14. Portsmouth On-Site Disposal Cell High Density Polyethylene Geomembrane Longevity

    International Nuclear Information System (INIS)

    Phifer, M.

    2012-01-01

    It is anticipated that high density polyethylene (HDPE) geomembranes will be utilized within the liner and closure cap of the proposed On-Site Disposal Cell (OSDC) at the Portsmouth Gaseous Diffusion Plant. The likely longevity (i.e. service life) of HDPE geomembranes in OSDC service is evaluated within the following sections of this report: (1) Section 2.0 provides an overview of HDPE geomembranes, (2) Section 3.0 outlines potential HDPE geomembranes degradation mechanisms, (3) Section 4.0 evaluates the applicability of HDPE geomembrane degradation mechanisms to the Portsmouth OSDC, (4) Section 5.0 provides a discussion of the current state of knowledge relative to the longevity (service life) of HDPE geomembranes, including the relation of this knowledge to the Portsmouth OSDC, and (5) Section 6.0 provides summary and conclusions relative to the anticipated service life of HDPE geomembranes in OSDC service. Based upon this evaluation it is anticipated that the service life of HDPE geomembranes in OSDC service would be significantly greater than the 200 year service life assumed for the OSDC closure cap and liner HDPE geomembranes. That is, a 200 year OSDC HDPE geomembrane service life is considered a conservative assumption.

  15. Nitrogen and carbon dynamics beneath on-site wastewater treatment systems in Pitt County, North Carolina.

    Science.gov (United States)

    Del Rosario, Katie L; Humphrey, Charles P; Mitra, Siddhartha; O'Driscoll, Michael A

    2014-01-01

    On-site wastewater treatment systems (OWS) are a potentially significant non-point source of nutrients to groundwater and surface waters, and are extensively used in coastal North Carolina. The goal of this study was to determine the treatment efficiency of four OWS in reducing total dissolved nitrogen (TDN) and dissolved organic carbon (DOC) concentrations before discharge to groundwater and/or adjacent surface water. Piezometers were installed for groundwater sample collection and nutrient analysis at four separate residences that use OWS. Septic tank effluent, groundwater, and surface water samples (from an adjacent stream) were collected four times during 2012 for TDN and DOC analysis and pH, temperature, electrical conductivity, and dissolved oxygen measurements. Treatment efficiencies from the tank to the groundwater beneath the drainfields ranged from 33 to 95% for TDN and 45 to 82% for DOC, although dilution accounted for most of the concentration reductions. There was a significant positive correlation between nitrate concentration and separation distance from trench bottom to water table and a significant negative correlation between DOC concentration and separation distance. The TDN and DOC transport (>15 m) from two OWS with groundwater saturated drainfield trenches was significant.

  16. Cold climate performance analysis of on-site domestic wastewater treatment systems.

    Science.gov (United States)

    Williamson, Eric

    2010-06-01

    Household on-site septic systems with secondary wastewater treatment in Anchorage, Alaska, were sampled and analyzed for performance parameters during the winter to spring months. System types included intermittent dosing sand filters (ISF), three types of recirculating trickling filters (RTF), and suspended-growth aeration tanks. Total nitrogen from the trickling filter and aeration tank effluent was fairly uniform, at approximately 30 mg/L. Total suspended solids (TSS) means were mostly less than 15 mg/L. The 5-day biochemical oxygen demand (BODs) showed considerable variability, with means ranging from 9.2 mg/ L for ISFs up to 39.5 mg/L for one type of RTF, even though this type has shown excellent results in several test programs. The data suggested that effluent temperature within the sample range had almost no effect on effluent concentrations of BOD5 or TSS and only a small effect on the removal of total nitrogen. Non-climatic factors were probably of equal importance to treatment results.

  17. Oxygen profile and clogging in vertical flow sand filters for on-site wastewater treatment.

    Science.gov (United States)

    Petitjean, A; Forquet, N; Boutin, C

    2016-04-01

    13 million people (about 20% of the population) use on-site wastewater treatment in France. Buried vertical sand filters are often built, especially when the soil permeability is not sufficient for septic tank effluent infiltration in undisturbed soil. Clogging is one of the main problems deteriorating the operation of vertical flow filters for wastewater treatment. The extent of clogging is not easily assessed, especially in buried vertical flow sand filters. We suggest examining two possible ways of detecting early clogging: (1) NH4-N/NO3-N outlet concentration ratio, and (2) oxygen measurement within the porous media. Two pilot-scale filters were equipped with probes for oxygen concentration measurements and samples were taken at different depths for pollutant characterization. Influent and effluent grab-samples were taken three times a week. The systems were operated using batch-feeding of septic tank effluent. Qualitative description of oxygen transfer processes under unclogged and clogged conditions is presented. NH4-N outlet concentration appears to be useless for early clogging detection. However, NO3-N outlet concentration and oxygen content allows us to diagnose the early clogging of the system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Engineered ecosystem for on-site wastewater treatment in tropical areas.

    Science.gov (United States)

    de Sá Salomão, André Luis; Marques, Marcia; Severo, Raul Gonçalves; da Cruz Roque, Odir Clécio

    2012-01-01

    There is a worldwide demand for decentralized wastewater treatment options. An on-site engineered ecosystem (EE) treatment plant was designed with a multistage approach for small wastewater generators in tropical areas. The array of treatment units included a septic tank, a submersed aerated filter, and a secondary decanter followed by three vegetated tanks containing aquatic macrophytes intercalated with one tank of algae. During 11 months of operation with a flow rate of 52 L h(-1), the system removed on average 93.2% and 92.9% of the chemical oxygen demand (COD) and volatile suspended solids (VSS) reaching final concentrations of 36.3 ± 12.7 and 13.7 ± 4.2 mg L(-1), respectively. Regarding ammonia-N (NH(4)-N) and total phosphorus (TP), the system removed on average 69.8% and 54.5% with final concentrations of 18.8 ± 9.3 and 14.0 ± 2.5 mg L(-1), respectively. The tanks with algae and macrophytes together contributed to the overall nutrient removal with 33.6% for NH(4)-N and 26.4% for TP. The final concentrations for all parameters except TP met the discharge threshold limits established by Brazilian and EU legislation. The EE was considered appropriate for the purpose for which it was created.

  19. Single house on-site grey water treatment using a submerged membrane bioreactor for toilet flushing.

    Science.gov (United States)

    Fountoulakis, M S; Markakis, N; Petousi, I; Manios, T

    2016-05-01

    Wastewater recycling has been and continues to be practiced all over the world for a variety of reasons including: increasing water availability, combating water shortages and drought, and supporting environmental and public health protection. Nowadays, one of the most interesting issues for wastewater recycling is the on-site treatment and reuse of grey water. During this study the efficiency of a compact Submerged Membrane Bioreactor (SMBR) system to treat real grey water in a single house in Crete, Greece, was examined. In the study, grey water was collected from a bathtub, shower and washing machine containing significant amounts of organic matter and pathogens. Chemical oxygen demand (COD) removal in the system was approximately 87%. Total suspended solids (TSS) were reduced from 95mgL(-1) in the influent to 8mgL(-1) in the effluent. The efficiency of the system to reduce anionic surfactants was about 80%. Fecal and total coliforms decreased significantly using the SMBR system due to rejection, by the membrane, used in the study. Overall, the SMBR treatment produces average effluent values that would satisfy international guidelines for indoor reuse applications such as toilet flushing. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. A uniform approach for on-site training and qualification of health physics technicians

    International Nuclear Information System (INIS)

    Till, J.E.

    1977-01-01

    Estimates show that in the U.S. approx. 75% of the health physics technicians received their training through courses offered by their employer. The quality and the extent of this training vary considerably among nuclear facilities. This paper describes a uniform approach for on-site training and qualification of health physics technicians applicable to all nuclear facilities. The program consists of four levels of qualification: Health Physics Technician Trainee, Technician I, Technician II and Senior Technician. The training is divided into modules that are composed of formal lectures, practical factors, experience, and a comprehensive examination. The minimum time required from hiring of inexperienced trainees to qualification as Senior Technicians is approx. 24 months. A qualification guide lists each step a technician must complete in the training program and provides documentation which facilitates audits by internal and external groups. Although items in the program would differ between facilities, the program provides specific titles for technicians, based on their training and experience, which would be applicable throughout the nuclear industry. (author)

  1. Distributed Energy Resources On-Site Optimization for Commercial Buildings with Electric and Thermal Storage Technologies

    International Nuclear Information System (INIS)

    Lacommare, Kristina S H; Stadler, Michael; Aki, Hirohisa; Firestone, Ryan; Lai, Judy; Marnay, Chris; Siddiqui, Afzal

    2008-01-01

    The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic as well as environmental attractiveness of on-site generation (e.g., PV, fuel cells, reciprocating engines or microturbines operating with or without CHP) and contribute to enhanced demand response. In order to examine the impact of storage technologies on demand response and carbon emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that has the minimization of annual energy costs as its objective function. By implementing this approach in the General Algebraic Modeling System (GAMS), the problem is solved for a given test year at representative customer sites, such as schools and nursing homes, to obtain not only the level of technology investment, but also the optimal hourly operating schedules. This paper focuses on analysis of storage technologies in DER optimization on a building level, with example applications for commercial buildings. Preliminary analysis indicates that storage technologies respond effectively to time-varying electricity prices, i.e., by charging batteries during periods of low electricity prices and discharging them during peak hours. The results also indicate that storage technologies significantly alter the residual load profile, which can contribute to lower carbon emissions depending on the test site, its load profile, and its adopted DER technologies

  2. On site experiments of the slanted soil treatment systems for domestic gray water.

    Science.gov (United States)

    Itayama, Tomoaki; Kiji, Masato; Suetsugu, Aya; Tanaka, Nobuyuki; Saito, Takeshi; Iwami, Norio; Mizuochi, Motoyuki; Inamori, Yuhei

    2006-01-01

    In order to make a breakthrough for the acute problem of water shortage in the world, the key words "decentralization and re-use" are very important for new sustainable sanitation systems that will be developed. Therefore, we focused on a new treatments system called "a slanted soil treatment system" which combines a biotoilet system with a domestic grey water treatment system. Because this system is a low cost and compact system, the system can be easily introduced to homes in urban areas or in the suburbs of cities in many developing countries. In this study, we performed on site experiments carried out on Shikoku Island, Japan, for several years. We obtained the following results. The slanted soil treatment system could remove organic pollutants and total nitrogen and total phosphorus in grey water effectively. Furthermore, the system performance became high in the case of the high concentration of the influent water. The nitrification reaction and denitrification reaction were speculated to exist due to aerobic zones and anaerobic zones present in the slanted soil treatment system. The slanted soil treatment system could perform for approximately 3 years with zero maintenance. The plug flow model of 1st order reaction kinetics could describe the reaction in the slanted soil treatment system. However, it is necessary to improve the system to maintain the performance in all seasons.

  3. BIPM direct on-site Josephson voltage standard comparisons: 20 years of results

    International Nuclear Information System (INIS)

    Solve, Stephane; Stock, Michael

    2012-01-01

    The discovery of the Josephson effect has for the first time given national metrology institutes (NMIs) the possibility of maintaining voltage references which are stable in time. In addition, the introduction in 1990 of a conventional value for the Josephson constant, K J-90 , has greatly improved world-wide consistency among representations of the volt. For 20 years, the Bureau International des Poids et Mesures (BIPM) has conducted an ongoing, direct, on-site key comparison of Josephson voltage standards among NMIs under the denominations BIPM.EM-K10.a (1 V) and BIPM.EM-K10.b (10 V) in the framework of the mutual recognition arrangement (CIPM MRA). The results of 41 comparisons illustrate the consistency among primary voltage standards and have demonstrated that a relative total uncertainty of a few parts in 10 10 is achievable if a few precautions are taken with regard to the measurement set-up. Of particular importance are the grounding, efficient filters and high insulation resistance of the measurement leads, and clean microwave distribution along the propagation line to the Josephson array. This paper reviews the comparison scheme and technical issues that need to be taken into account to achieve a relative uncertainty at the level of a few parts in 10 10 or even a few parts in 10 11 in the best cases. (paper)

  4. Flexible OSSC or the on-site storage alternative and how it grew

    International Nuclear Information System (INIS)

    Dufrane, K.H.

    1986-01-01

    The On-Site Storage Container (OSSC) is an accepted and proven concept currently in widespread use for both operations and the storage of low level radioactive waste. In addition, it represents a very attractive enhancement to a geological low-level waste disposal site. Use of the proven OSSC concept at a site can provide additional safety to the environment by combining the benefits of an engineered storage facility with the proven safety of a sound geological repository. The concept of flexibility which was built into the OSSC concept for the temporary above ground storage of low-level waste is directly applicable to a permanent storage facility. Manufacturing costs, size flexibility, handling systems, and real-world operational advantages are well known and proven. This background provides a high confidence level for adapting this technology to a disposal site while keeping in mind the significance of both operational economics, safety to the environment, and ALARA principles. The development, design and cost effectiveness features of the OSSC as a temporary storage facility are discussed in detail. The flexible OSSC provides significant economic advantages over a permanent storage building. The application of the OSSC to a permanent geological disposal site provides the environmental advantages of an engineered facility while maintaining the inherent operational and economic benefits of the flexible OSSC concept

  5. The UASB reactor as an alternative for the septic tank for on-site sewage treatment.

    Science.gov (United States)

    Coelho, A L S S; do Nascimento, M B H; Cavalcanti, P F F; van Haandel, A C

    2003-01-01

    Although septic tanks are amply used for on site sewage treatment, these units have serious drawbacks: the removal efficiency of organic material and suspended solids is low, the units are costly and occupy a large area and operational cost is high due to the need for periodic desludging. In this paper an innovative variant of the UASB reactor is proposed as an alternative for the septic tank. This alternative has several important advantages in comparison with the conventional septic tank: (1) Although the volume of the UASB reactor was about 4 times smaller than the septic tank, its effluent quality was superior, even though small sludge particles were present, (2) desludging of the UASB reactor is unnecessary and even counterproductive, as the sludge mass guarantees proper performance, (3) the UASB reactor is easily transportable (compact and light) and therefore can be produced in series, strongly reducing construction costs and (4) since the concentration of colloids in the UASB effluent is much smaller than in the ST effluent, it is expected that the infiltration of the effluent will be much less problematic.

  6. Application of On-Site Wastewater Treatment in Ireland and Perspectives on Its Sustainability

    Directory of Open Access Journals (Sweden)

    Donata Dubber

    2014-03-01

    Full Text Available The wastewater of one third of Ireland’s population is treated on-site using domestic treatment systems (DWWTSs that usually consist of a septic tank and soil attenuation system. Within the past four years, the legislative framework for these systems has undergone a major change with a registration and inspection regime being introduced to identify legacy sites that will require remediation work, particularly in areas of the country underlain by subsoils of very low permeability. Against this background this study aims to assess the overall sustainability of existing DWWTSs as well as alternative treatment and disposal options. The results show that main CO2eq emissions are from the methane production in septic tanks. The reduced methane production in mechanically aerated secondary treatment systems was found to counterbalance the related emissions due to the additional energy requirements. In contrast, septic tank systems have the lowest construction and operational costs representing the most economically sustainable solution. Pressurised disposal systems are slightly more expensive but have the potential to reduce environmental impact on surface water and reduce greenhouse gas emissions. Clustered decentralised treatment solutions could be environmentally and economically sustainable but ownership, management and related financial and legal issues will need to be addressed and developed.

  7. Upflow Evapotranspiration System for the Treatment of On-Site Wastewater Effluent

    Directory of Open Access Journals (Sweden)

    Sean Curneen

    2015-05-01

    Full Text Available Full-scale willow evapotranspiration systems fed from the base with septic tank or secondary treated domestic effluent from single houses have been constructed and instrumented in Ireland in order to investigate whether the technology could provide a solution to the problem of on-site effluent disposal in areas with low permeability subsoils. Continuous monitoring of rainfall, reference evapotranspiration, effluent flows and water level in the sealed systems revealed varying evapotranspiration rates across the different seasons. No system managed to achieve zero discharge in any year remaining at maximum levels for much of the winter months, indicating some loss of water by lateral exfiltration at the surface. Water sampling and analysis however, showed that the quality of any surface overflow from the systems was similar to rainfall runoff. The performance results have then been used to formulate design guidelines for such systems in Ireland’s temperate maritime climate. The effect of varying different combinations of design parameters (plan area, soil depth, etc. has been evaluated with respect to the simulated number of overflow days over a five-year period using a water balance model. Design guidelines have then been based upon minimising the amount of runoff, in conjunction with other practical and financial considerations.

  8. PORTSMOUTH ON-SITE DISPOSAL CELL HIGH DENSITY POLYETHYLENE GEOMEMBRANE LONGEVITY

    Energy Technology Data Exchange (ETDEWEB)

    Phifer, M.

    2012-01-31

    It is anticipated that high density polyethylene (HDPE) geomembranes will be utilized within the liner and closure cap of the proposed On-Site Disposal Cell (OSDC) at the Portsmouth Gaseous Diffusion Plant. The likely longevity (i.e. service life) of HDPE geomembranes in OSDC service is evaluated within the following sections of this report: (1) Section 2.0 provides an overview of HDPE geomembranes, (2) Section 3.0 outlines potential HDPE geomembranes degradation mechanisms, (3) Section 4.0 evaluates the applicability of HDPE geomembrane degradation mechanisms to the Portsmouth OSDC, (4) Section 5.0 provides a discussion of the current state of knowledge relative to the longevity (service life) of HDPE geomembranes, including the relation of this knowledge to the Portsmouth OSDC, and (5) Section 6.0 provides summary and conclusions relative to the anticipated service life of HDPE geomembranes in OSDC service. Based upon this evaluation it is anticipated that the service life of HDPE geomembranes in OSDC service would be significantly greater than the 200 year service life assumed for the OSDC closure cap and liner HDPE geomembranes. That is, a 200 year OSDC HDPE geomembrane service life is considered a conservative assumption.

  9. On-site laboratory support of Oak Ridge National Laboratory environmental restoration field activities

    International Nuclear Information System (INIS)

    Burn, J.L.E.

    1995-07-01

    A remedial investigation/feasibility study has been undertaken at Oak Ridge National Laboratory (ORNL). Bechtel National, Inc. and partners CH2M Hill, Ogden Environmental and Energy Services, and PEER Consultants are contracted to Lockheed Martin Energy Systems, performing this work for ORNL's Environmental Restoration (ER) Program. An on-site Close Support Laboratory (CSL) established at the ER Field Operations Facility has evolved into a laboratory where quality analytical screening results can be provided rapidly (e.g., within 24 hours of sampling). CSL capabilities include three basic areas: radiochemistry, chromatography, and wet chemistry. Radiochemical analyses include gamma spectroscopy, tritium and carbon-14 screens using liquid scintillation analysis, and gross alpha and beta counting. Cerenkov counting and crown-ether-based separation are the two rapid methods used for radiostrontium determination in water samples. By extending count times where appropriate, method detection limits can match those achieved by off-site contract laboratories. Volatile organic compounds are detected by means of gas chromatography using either headspace or purge and trap sample introduction (based on EPA 601/602). Ionic content of water samples is determined using ion chromatography and alkalinity measurement. Ion chromatography is used to quantify both anions (based on EPA 300) and cations. Wet chemistry procedures performed at the CSL include alkalinity, pH (water and soil), soil resistivity, and dissolved/suspended solids. Besides environmental samples, the CSL routinely screens health and safety and waste management samples. The cost savings of the CSL are both direct and indirect

  10. An Explosion Aftershock Model with Application to On-Site Inspection

    Science.gov (United States)

    Ford, Sean R.; Labak, Peter

    2016-01-01

    An estimate of aftershock activity due to a theoretical underground nuclear explosion is produced using an aftershock rate model. The model is developed with data from the Nevada National Security Site, formerly known as the Nevada Test Site, and the Semipalatinsk Test Site, which we take to represent soft-rock and hard-rock testing environments, respectively. Estimates of expected magnitude and number of aftershocks are calculated using the models for different testing and inspection scenarios. These estimates can help inform the Seismic Aftershock Monitoring System (SAMS) deployment in a potential Comprehensive Test Ban Treaty On-Site Inspection (OSI), by giving the OSI team a probabilistic assessment of potential aftershocks in the Inspection Area (IA). The aftershock assessment, combined with an estimate of the background seismicity in the IA and an empirically derived map of threshold magnitude for the SAMS network, could aid the OSI team in reporting. We apply the hard-rock model to a M5 event and combine it with the very sensitive detection threshold for OSI sensors to show that tens of events per day are expected up to a month after an explosion measured several kilometers away.

  11. A C. elegans-based foam for rapid on-site detection of residual live virus.

    Energy Technology Data Exchange (ETDEWEB)

    Negrete, Oscar A.; Branda, Catherine; Hardesty, Jasper O. E. (Sandia National Laboratories, Albuquerque, NM); Tucker, Mark David (Sandia National Laboratories, Albuquerque, NM); Kaiser, Julia N. (Global Product Management, Hilden, Germany); Kozina, Carol L.; Chirica, Gabriela S.

    2012-02-01

    In the response to and recovery from a critical homeland security event involving deliberate or accidental release of biological agents, initial decontamination efforts are necessarily followed by tests for the presence of residual live virus or bacteria. Such 'clearance sampling' should be rapid and accurate, to inform decision makers as they take appropriate action to ensure the safety of the public and of operational personnel. However, the current protocol for clearance sampling is extremely time-intensive and costly, and requires significant amounts of laboratory space and capacity. Detection of residual live virus is particularly problematic and time-consuming, as it requires evaluation of replication potential within a eukaryotic host such as chicken embryos. The intention of this project was to develop a new method for clearance sampling, by leveraging Sandia's expertise in the biological and material sciences in order to create a C. elegans-based foam that could be applied directly to the entire contaminated area for quick and accurate detection of any and all residual live virus by means of a fluorescent signal. Such a novel technology for rapid, on-site detection of live virus would greatly interest the DHS, DoD, and EPA, and hold broad commercial potential, especially with regard to the transportation industry.

  12. Risk-Cost Estimation of On-Site Wastewater Treatment System Failures Using Extreme Value Analysis.

    Science.gov (United States)

    Kohler, Laura E; Silverstein, JoAnn; Rajagopalan, Balaji

    2017-05-01

      Owner resistance to increasing regulation of on-site wastewater treatment systems (OWTS), including obligatory inspections and upgrades, moratoriums and cease-and-desist orders in communities around the U.S. demonstrate the challenges associated with managing risks of inadequate performance of owner-operated wastewater treatment systems. As a result, determining appropriate and enforceable performance measures in an industry with little history of these requirements is challenging. To better support such measures, we develop a statistical method to predict lifetime failure risks, expressed as costs, in order to identify operational factors associated with costly repairs and replacement. A binomial logistic regression is used to fit data from public records of reported OWTS failures, in Boulder County, Colorado, which has 14 300 OWTS to determine the probability that an OWTS will be in a low- or high-risk category for lifetime repair and replacement costs. High-performing or low risk OWTS with repairs and replacements below the threshold of $9000 over a 40-year life are associated with more frequent inspections and upgrades following home additions. OWTS with a high risk of exceeding the repair cost threshold of $18 000 are further analyzed in a variation of extreme value analysis (EVA), Points Over Threshold (POT) where the distribution of risk-cost exceedance values are represented by a generalized Pareto distribution. The resulting threshold cost exceedance estimates for OWTS in the high-risk category over a 40-year expected life ranged from $18 000 to $44 000.

  13. Spent-fuel storage - MRS and/or on-site?

    International Nuclear Information System (INIS)

    Fuierer, A.A.

    1991-01-01

    The US government through the Office of Civilian Radioactive Waste Management (OCRWM) is seeking by the use of an authorized negotiator a site for a monitored retrievable storage (MRS) facility. Based on a public information document provided by the office of the negotiator, the MRS will be an integral part of the federal system for safe and permanent disposal of the nation's high-level radioactive wastes. It is planned that the MRS will accept and store spent fuel above ground until a repository opens and spent fuel that has been stored is shipped from the MRS to the repository. Additional spent fuel stored at reactor sites will be shipped to the MRS, which will be used as a staging area to assemble dedicated trains for shipment to the repository. The intent of the MRS is to reduce utilities' needs to expand on-site storage of spent fuel. A utility viewpoint may emphasize an alternate set of priorities. The waste management system must be considered as an overall system involving both the utility and DOE that begins with the first discharge of spent nuclear fuel from a commercial reactor and ends with high-level waste in a final repository. Many studies have been made on individual components of a waste system. This study, with the benefit of past hands-on experience as a guide, looks at costs and reliability for a total system concept with particular emphasis on the interface between the utility and Department of Energy

  14. Bioremediation techniques-classification based on site of application: principles, advantages, limitations and prospects.

    Science.gov (United States)

    Azubuike, Christopher Chibueze; Chikere, Chioma Blaise; Okpokwasili, Gideon Chijioke

    2016-11-01

    Environmental pollution has been on the rise in the past few decades owing to increased human activities on energy reservoirs, unsafe agricultural practices and rapid industrialization. Amongst the pollutants that are of environmental and public health concerns due to their toxicities are: heavy metals, nuclear wastes, pesticides, green house gases, and hydrocarbons. Remediation of polluted sites using microbial process (bioremediation) has proven effective and reliable due to its eco-friendly features. Bioremediation can either be carried out ex situ or in situ, depending on several factors, which include but not limited to cost, site characteristics, type and concentration of pollutants. Generally, ex situ techniques apparently are more expensive compared to in situ techniques as a result of additional cost attributable to excavation. However, cost of on-site installation of equipment, and inability to effectively visualize and control the subsurface of polluted sites are of major concerns when carrying out in situ bioremediation. Therefore, choosing appropriate bioremediation technique, which will effectively reduce pollutant concentrations to an innocuous state, is crucial for a successful bioremediation project. Furthermore, the two major approaches to enhance bioremediation are biostimulation and bioaugmentation provided that environmental factors, which determine the success of bioremediation, are maintained at optimal range. This review provides more insight into the two major bioremediation techniques, their principles, advantages, limitations and prospects.

  15. Lightdrum—Portable Light Stage for Accurate BTF Measurement on Site

    Directory of Open Access Journals (Sweden)

    Vlastimil Havran

    2017-02-01

    Full Text Available We propose a miniaturised light stage for measuring the bidirectional reflectance distribution function (BRDF and the bidirectional texture function (BTF of surfaces on site in real world application scenarios. The main principle of our lightweight BTF acquisition gantry is a compact hemispherical skeleton with cameras along the meridian and with light emitting diode (LED modules shining light onto a sample surface. The proposed device is portable and achieves a high speed of measurement while maintaining high degree of accuracy. While the positions of the LEDs are fixed on the hemisphere, the cameras allow us to cover the range of the zenith angle from 0 ∘ to 75 ∘ and by rotating the cameras along the axis of the hemisphere we can cover all possible camera directions. This allows us to take measurements with almost the same quality as existing stationary BTF gantries. Two degrees of freedom can be set arbitrarily for measurements and the other two degrees of freedom are fixed, which provides a tradeoff between accuracy of measurements and practical applicability. Assuming that a measured sample is locally flat and spatially accessible, we can set the correct perpendicular direction against the measured sample by means of an auto-collimator prior to measuring. Further, we have designed and used a marker sticker method to allow for the easy rectification and alignment of acquired images during data processing. We show the results of our approach by images rendered for 36 measured material samples.

  16. Power corrupts

    International Nuclear Information System (INIS)

    Bacon, H.; Valentine, J.

    1981-01-01

    The subject is covered in chapters, entitled: radiation (hazards associated with nuclear power production); wastes (radioactive wastes); accidents (actual and postulated, resulting in the release of radiation); the FBR and the plutonium cycle; costs (economics of nuclear power); spent fuel transport; civil liberties; doing without nuclear power (UK power demand; low energy strategy; energy policy; government policies; alternative energy sources). (U.K.)

  17. Application of micro-solid-phase extraction for the on-site extraction of heterocyclic aromatic amines in seawater.

    Science.gov (United States)

    Basheer, Chanbasha

    2018-04-01

    An efficient on-site extraction technique to determine carcinogenic heterocyclic aromatic amines in seawater has been reported. A micro-solid-phase extraction device placed inside a portable battery-operated pump was used for the on-site extraction of seawater samples. Before on-site applications, parameters that influence the extraction efficiency (extraction time, type of sorbent materials, suitable desorption solvent, desorption time, and sample volume) were investigated and optimized in the laboratory. The developed method was then used for the on-site sampling of heterocyclic aromatic amines determination in seawater samples close to distillation plant. Once the on-site extraction completed, the small extraction device with the analytes was brought back to the laboratory for analysis using high-performance liquid chromatography with fluorescence detection. Based on the optimized conditions, the calibration curves were linear over the concentration range of 0.05-20 μg/L with correlation coefficients up to 0.996. The limits of detection were 0.004-0.026 μg/L, and the reproducibility values were between 1.3 and 7.5%. To evaluate the extraction efficiency, a comparison was made with conventional solid-phase extraction and it was applied to various fortified real seawater samples. The average relative recoveries obtained from the spiked seawater samples varied in the range 79.9-95.2%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. On-site Destruction of Radioactive Oily Wastes Using Adsorption Coupled with Electrochemical Regeneration - 12221

    Energy Technology Data Exchange (ETDEWEB)

    Brown, N.W. [Arvia Technology Ltd, Daresbury Innovation Centre, Daresbury, WA4 4FS (United Kingdom); Wickenden, D.A. [Magnox Ltd, Berkeley Centre, Gloucestershire, GL13 9PB (United Kingdom); Roberts, E.P.L. [School of Chemical Engineering, University of Manchester, Manchester, M60 1QD (United Kingdom)

    2012-07-01

    Arvia{sup R}, working with Magnox Ltd, has developed the technology of adsorption coupled with electrochemical regeneration for the degradation of orphan radioactive oil wastes. The process results in the complete destruction of the organic phase where the radioactivity is transferred to liquid and solid secondary wastes that can then be processed using existing authorised on-site waste-treatment facilities.. Following on from successful laboratory and pilot scale trials, a full scale, site based demonstrator unit was commissioned at the Magnox Trawsfynydd decommissioning site to destroy 10 l of LLW and ILW radioactive oils. Over 99% of the emulsified oil was removed and destroyed with the majority of activity (80 - 90%) being transferred to the aqueous phase. Secondary wastes were disposed of via existing routes with the majority being disposed of via the sites active effluent treatment plant. The regeneration energy required to destroy a litre of oil was 42.5 kWh/l oil. This on-site treatment approach eliminates the risks and cost associated with transporting the active waste oils off site for incineration or other treatment. The Arvia{sup R} process of adsorption coupled with electrochemical regeneration has successfully demonstrated the removal and destruction of LLW and ILW radioactive oils on a nuclear site. Over 99.9% of the emulsified oil was removed, with the majority of the radioactive species transferred to the aqueous, supernate, phase (typically 80 - 90 %). The exception to this is Cs-137 which appears to be more evenly distributed, with 43% associated with the liquid phase and 33 % with the Nyex, the remainder associated with the electrode bed. The situation with Plutonium may be similar, but this requires confirmation, hence further work is underway to understand the full nature of the electrode bed radioactive burden and its distribution within the body of the electrodes. - Tritium gaseous discharges were negligible; hence no off-gas treatment

  19. Scaled effective on-site Coulomb interaction in the DFT+U method for correlated materials

    Science.gov (United States)

    Nawa, Kenji; Akiyama, Toru; Ito, Tomonori; Nakamura, Kohji; Oguchi, Tamio; Weinert, M.

    2018-01-01

    The first-principles calculation of correlated materials within density functional theory remains challenging, but the inclusion of a Hubbard-type effective on-site Coulomb term (Ueff) often provides a computationally tractable and physically reasonable approach. However, the reported values of Ueff vary widely, even for the same ionic state and the same material. Since the final physical results can depend critically on the choice of parameter and the computational details, there is a need to have a consistent procedure to choose an appropriate one. We revisit this issue from constraint density functional theory, using the full-potential linearized augmented plane wave method. The calculated Ueff parameters for the prototypical transition-metal monoxides—MnO, FeO, CoO, and NiO—are found to depend significantly on the muffin-tin radius RMT, with variations of more than 2-3 eV as RMT changes from 2.0 to 2.7 aB. Despite this large variation in Ueff, the calculated valence bands differ only slightly. Moreover, we find an approximately linear relationship between Ueff(RMT) and the number of occupied localized electrons within the sphere, and give a simple scaling argument for Ueff; these results provide a rationalization for the large variation in reported values. Although our results imply that Ueff values are not directly transferable among different calculation methods (or even the same one with different input parameters such as RMT), use of this scaling relationship should help simplify the choice of Ueff.

  20. The project on site - setting the scene for successful industrial relations

    International Nuclear Information System (INIS)

    Morris, D.; Kershaw, A.R.

    1989-01-01

    The site construction performance at Torness and Heysham 2 has been described in various other papers during the Conference and in common with other large projects undertaken over the last 20 years a final judgement will be made as to whether, in simple terms, they were ''good'' or ''bad'' sites. Although there are many individuals or organisations who may make this judgement, it is unlikely that the basic conclusion will differ. What may differ however is the list of reasons that will be advanced to explain the final result. Looking at the investigations made into past projects, the reasons advanced for their success or otherwise can range from the geographical location of the site to material delivery problems, design changes, safety issues, or even the state of the overall national economic climate during the period under scrutiny. Where industrial relations problems are singled out, they can usually be linked to one or more of the factors mentioned. When looking at the complexity of projects such as Torness and Heysham, it is to be expected that unlooked for difficulties and problems will always arise but it is equally true that there is sufficient experience and expertise available in the industry for many possible problem areas to be anticipated and ''designed'' out before work even commences on site. This paper will be looking at the clients' role in creating a suitable environment for contractors to fully manage all aspects of their site operation and to ensure that acute problems can receive the full attention of all parties and not have to be set against a continuing background of unnecessary irritations. (author)

  1. On site remediation of a fuel spill and soil reuse in Antarctica.

    Science.gov (United States)

    McWatters, R S; Wilkins, D; Spedding, T; Hince, G; Raymond, B; Lagerewskij, G; Terry, D; Wise, L; Snape, I

    2016-11-15

    The first large-scale remediation of fuel contamination in Antarctica treated 10000L of diesel dispersed in 1700t of soil, and demonstrated the efficacy of on-site bioremediation. The project progressed through initial site assessment and natural attenuation, passive groundwater management, then active remediation and the managed reuse of soil. Monitoring natural attenuation for the first 12years showed contaminant levels in surface soil remained elevated, averaging 5000mg/kg. By contrast, in five years of active remediation (excavation and biopile treatment) contaminant levels decreased by a factor of four. Chemical indicators showed hydrocarbon loss was apportioned to both biodegradation and evaporative processes. Hydrocarbon degradation rates were assessed against biopile soil temperatures, showing a phase of rapid degradation (first 100days above soil temperature threshold of 0°C) followed by slower degradation (beyond 100days above threshold). The biopiles operated successfully within constraints typical of harsh climates and remote sites, including limitations on resources, no external energy inputs and short field seasons. Non-native microorganisms (e.g. inoculations) and other organic materials (e.g. bulking agents) are prohibited in Antarctica making this cold region more challenging for remediation than the Arctic. Biopile operations included an initial fertiliser application, biannual mechanical turning of the soil and minimal leachate recirculation. The biopiles are a practical approach to remediate large quantities of contaminated soil in the Antarctic and already 370t have been reused in a building foundation. The findings presented demonstrate that bioremediation is a viable strategy for Antarctica and other cold regions. Operators can potentially use the modelled relationship between days above 0°C (threshold temperature) and the change in degradation rates to estimate how long it would take to remediate other sites using the biopile technology

  2. A small-scale flow alkaline fuel cell for on-site production of hydrogen peroxide

    International Nuclear Information System (INIS)

    Brillas, Enric; Alcaide, Francisco; Cabot, Pere-Lluis

    2002-01-01

    The behavior of a small-scale flow alkaline fuel cell (AFC) built-up for on-site production of HO 2 - using commercial gas-diffusion electrodes has been studied. It produces a spontaneous current due to the oxidation of H 2 to H 2 O at the H 2 -diffusion anode and the reduction of O 2 to HO 2 - at the O 2 -diffusion cathode, while a fresh 1.0-6.0 mol dm -3 KOH electrolyte at 15.0-45.0 deg. C is injected through it. Under circulation of HO 2 - +KOH solutions in open circuit, the flow AFC behaves as a two-electron reversible system. When it is shorted with an external load (R ext ), steady cell voltage-current density curves are found. The use of O 2 /N 2 mixtures to fed the cathode causes a loss of its performance, being required to supply pure O 2 to yield a maximum HO 2 - electrogeneration. The current density and HO 2 - productivity increase with raising OH - concentration, temperature and pressure of O 2 fed. At R ext =0.10 Ω, a current efficiency close to 100% is obtained, and current densities >100 mA cm -2 are achieved for 1.0 mol dm -3 KOH at 45.0 deg. C and for higher KOH concentrations at 25.0 deg. C. The flow AFC can work under optimum conditions up to 6.0 mol dm -3 KOH and 45.0 deg. C for possible industrial applications

  3. A portable bioluminescence engineered cell-based biosensor for on-site applications.

    Science.gov (United States)

    Roda, Aldo; Cevenini, Luca; Michelini, Elisa; Branchini, Bruce R

    2011-04-15

    We have developed a portable biosensing device based on genetically engineered bioluminescent (BL) cells. Cells were immobilized on a 4 × 3 multiwell cartridge using a new biocompatible matrix that preserved their vitality. Using a fiber optic taper, the cartridge was placed in direct contact with a cooled CCD sensor to image and quantify the BL signals. Yeast and bacterial cells were engineered to express recognition elements, whose interaction with the analyte led to luciferase expression, via reporter gene technology. Three different biosensors were developed. The first detects androgenic compounds using yeast cells carrying a green-emitting P. pyralis luciferase regulated by the human androgen receptor and a red mutant of the same species as internal vitality control. The second biosensor detects two classes of compounds (androgens and estrogens) using yeast strains engineered to express green-or red-emitting mutant firefly luciferases in response to androgens or estrogens, respectively. The third biosensor detects lactose analogue isopropyl β-d-1-thiogalactopyranoside using two E. coli strains. One strain exploits the lac operon as recognition element for the expression of P. pyralis luciferase. The other strain serves as a vitality control expressing Gaussia princeps luciferase, which requires a different luciferin substrate. The immobilized cells were stable for up to 1 month. The analytes could be detected at nanomolar levels with good precision and accuracy when the specific signal was corrected using the internal vitality control. This portable device can be used for on-site multiplexed bioassays for different compound classes. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. On-site inspections under the INF Treaty. A post-mortem

    International Nuclear Information System (INIS)

    Russell, J.

    2001-01-01

    Midnight on 31 May 2001 marked the end of all on-site inspections (OSIs) under the Intermediate-range Nuclear Forces (INF) Treaty. Signed by the US and the Soviet Union in 1987, the treaty has now come of age and must survive for the rest of its indefinite duration without the security of regular OSIs. The ending of OSIs provides an opportunity to assess the success of this aspect of the verification regime and how the treaty is to be verified without them. The INF Treaty banned all ground-launched ballistic and cruise missiles with ranges between 500 and 5,500 kilometres. It was the first treaty to eliminate a whole class of nuclear weapons and the first nuclear arms control agreement to provide for OSIs. All 2,692 INF missiles were eliminated by May 1991, within the three-year time limit. A further 10 years of OSIs helped provide reassurance of continuing compliance. The treaty will continue to be verified by so-called national technical means, primarily satellites. The Special Verification Commission, set up under the treaty to resolve issues relating to treaty implementation and compliance, will continue to meet when requested by a treaty party. Universal opinion is that the treaty has been successfully verified to date. However, a number of problems were encountered and lessons learned from the experience. In particular, the treaty negotiators proved to have been overly cautious in envisaging how inspections would actually be conducted. One of the main achievements of OSIs under the INF Treaty has been to create a basic model and procedures for inspections which have been adopted in the more complex arms control and disarmament treaties that have followed

  5. Residential on site solar heating systems: a project evaluation using the capital asset pricing model

    Energy Technology Data Exchange (ETDEWEB)

    Schutz, S.R.

    1978-12-01

    An energy source ready for immediate use on a commercial scale is solar energy in the form of On Site Solar Heating (OSSH) systems. These systems collect solar energy with rooftop panels, store excess energy in water storage tanks and can, in certain circumstances, provide 100% of the space heating and hot water required by the occupants of the residential or commercial structure on which the system is located. Such systems would take advantage of a free and inexhaustible energy source--sunlight. The principal drawback of such systems is the high initial capital cost. The solution would normally be a carefully worked out corporate financing plan. However, at the moment it is individual homeowners and not corporations who are attempting to finance these systems. As a result, the terms of finance are excessively stringent and constitute the main obstacle to the large scale market penetration of OSSH. This study analyzes the feasibility of OSSH as a private utility investment. Such systems would be installed and owned by private utilities and would displace other investment projects, principally electric generating plants. The return on OSSH is calculated on the basis of the cost to the consumer of the equivalent amount of electrical energy that is displaced by the OSSH system. The hurdle rate for investment in OSSH is calculated using the Sharpe--Lintner Capital Asset Pricing Model. The results of this study indicate that OSSH is a low risk investment having an appropriate hurdle rate of 7.9%. At this rate, OSSH investment appears marginally acceptable in northern California and unambiguously acceptable in southern California. The results also suggest that utility investment in OSSH should lead to a higher degree of financial leverage for utility companies without a concurrent deterioration in the risk class of utility equity.

  6. The evaluation of effective criteria on site selection for energy production units from cellulosic biomass in Iran

    Directory of Open Access Journals (Sweden)

    Majid Azizi

    2017-12-01

    Full Text Available Both Analytical Hierarchy Process (AHP and benefits, opportunities, costs and risks (BOCR techniques were used successfully to evaluate the effective criteria on site selection for energy production unit development from cellulosic biomass in Iran. The results showed that the benefits criteria was at the first level while the initial cellulosic raw materials and opportunities with the aim of the local economy had the second position as the most important indices on site selection. In addition, third criterion has been introduced for the costs criteria (transportation cost and social barriers by the experts. However, risks criteria which referred to instability of providing cellulosic raw materials is one of the less important effective indices on site selection to make energy production unit. The results illustrated that the economy and politics as two environmental effective factors affected on the site selection process generally.

  7. ALL-PATHWAYS DOSE ANALYSIS FOR THE PORTSMOUTH ON-SITE WASTE DISPOSAL FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Smith, F.; Phifer, M.

    2014-04-10

    A Portsmouth On-Site Waste Disposal Facility (OSWDF) All-Pathways analysis has been conducted that considers the radiological impacts to a resident farmer. It is assumed that the resident farmer utilizes a farm pond contaminated by the OSWDF to irrigate a garden and pasture and water livestock from which food for the resident farmer is obtained, and that the farmer utilizes groundwater from the Berea sandstone aquifer for domestic purposes (i.e. drinking water and showering). As described by FBP 2014b the Hydrologic Evaluation of Landfill Performance (HELP) model (Schroeder et al. 1994) and the Surface Transport Over Multiple Phases (STOMP) model (White and Oostrom 2000, 2006) were used to model the flow and transport from the OSWDF to the Points of Assessment (POAs) associated with the 680-ft elevation sandstone layer (680 SSL) and the Berea sandstone aquifer. From this modeling the activity concentrations radionuclides were projected over time at the POAs. The activity concentrations were utilized as input to a GoldSimTM (GTG 2010) dose model, described herein, in order to project the dose to a resident farmer over time. A base case and five sensitivity cases were analyzed. The sensitivity cases included an evaluation of the impacts of using a conservative inventory, an uncased well to the Berea sandstone aquifer, a low waste zone uranium distribution coefficient (Kd), different transfer factors, and reference person exposure parameters (i.e. at 95 percentile). The maximum base case dose within the 1,000 year assessment period was projected to be 1.5E-14 mrem/yr, and the maximum base case dose at any time less than 10,000 years was projected to be 0.002 mrem/yr. The maximum projected dose of any sensitivity case was approximately 2.6 mrem/yr associated with the use of an uncased well to the Berea sandstone aquifer. This sensitivity case is considered very unlikely because it assumes leakage from the location of greatest concentration in the 680 SSL in to the

  8. Seismic aftershock monitoring for on-site inspection purposes. Experience from Integrated Field Exercise 2008.

    Science.gov (United States)

    Labak, P.; Arndt, R.; Villagran, M.

    2009-04-01

    One of the sub-goals of the Integrated Field Experiment in 2008 (IFE08) in Kazakhstan was testing the prototype elements of the Seismic aftershock monitoring system (SAMS) for on-site inspection purposes. The task of the SAMS is to collect the facts, which should help to clarify nature of the triggering event. Therefore the SAMS has to be capable to detect and identify events as small as magnitude -2 in the inspection area size up to 1000 km2. Equipment for 30 mini-arrays and 10 3-component stations represented the field equipment of the SAMS. Each mini-array consisted of a central 3-component seismometer and 3 vertical seismometers at the distance about 100 m from the central seismometer. The mini-arrays covered approximately 80% of surrogate inspection area (IA) on the territory of former Semipalatinsk test site. Most of the stations were installed during the first four days of field operations by the seismic sub-team, which consisted of 10 seismologists. SAMS data center comprised 2 IBM Blade centers and 8 working places for data archiving, detection list production and event analysis. A prototype of SAMS software was tested. Average daily amount of collected raw data was 15-30 GB and increased according to the amount of stations entering operation. Routine manual data screening and data analyses were performed by 2-6 subteam members. Automatic screening was used for selected time intervals. Screening was performed using the Sonoview program in frequency domain and using the Geotool and Hypolines programs for screening in time domain. The screening results were merged into the master event list. The master event list served as a basis of detailed analysis of unclear events and events identified to be potentially in the IA. Detailed analysis of events to be potentially in the IA was performed by the Hypoline and Geotool programs. In addition, the Hyposimplex and Hypocenter programs were also used for localization of events. The results of analysis were integrated

  9. NG09 And CTBT On-Site Inspection Noble Gas Sampling and Analysis Requirements

    Science.gov (United States)

    Carrigan, Charles R.; Tanaka, Junichi

    2010-05-01

    A provision of the Comprehensive Test Ban Treaty (CTBT) allows on-site inspections (OSIs) of suspect nuclear sites to determine if the occurrence of a detected event is nuclear in origin. For an underground nuclear explosion (UNE), the potential success of an OSI depends significantly on the containment scenario of the alleged event as well as the application of air and soil-gas radionuclide sampling techniques in a manner that takes into account both the suspect site geology and the gas transport physics. UNE scenarios may be broadly divided into categories involving the level of containment. The simplest to detect is a UNE that vents a significant portion of its radionuclide inventory and is readily detectable at distance by the International Monitoring System (IMS). The most well contained subsurface events will only be detectable during an OSI. In such cases, 37 Ar and radioactive xenon cavity gases may reach the surface through either "micro-seepage" or the barometric pumping process and only the careful siting of sampling locations, timing of sampling and application of the most site-appropriate atmospheric and soil-gas capturing methods will result in a confirmatory signal. The OSI noble gas field tests NG09 was recently held in Stupava, Slovakia to consider, in addition to other field sampling and analysis techniques, drilling and subsurface noble gas extraction methods that might be applied during an OSI. One of the experiments focused on challenges to soil-gas sampling near the soil-atmosphere interface. During withdrawal of soil gas from shallow, subsurface sample points, atmospheric dilution of the sample and the potential for introduction of unwanted atmospheric gases were considered. Tests were designed to evaluate surface infiltration and the ability of inflatable well-packers to seal out atmospheric gases during sample acquisition. We discuss these tests along with some model-based predictions regarding infiltration under different near

  10. Fusion power

    International Nuclear Information System (INIS)

    Hancox, R.

    1981-01-01

    The principles of fusion power, and its advantages and disadvantages, are outlined. Present research programmes and future plans directed towards the development of a fusion power reactor, are summarized. (U.K.)

  11. Power Electronics

    DEFF Research Database (Denmark)

    Iov, Florin; Ciobotaru, Mihai; Blaabjerg, Frede

    2008-01-01

    is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most...... emerging renewable energy sources, wind energy, which by means of power electronics are changing from being a minor energy source to be acting as an important power source in the energy system. Power electronics is the enabling technology and the presentation will cover the development in wind turbine...... technology from kW to MW, discuss which power electronic solutions are most feasible and used today....

  12. Normative Power

    DEFF Research Database (Denmark)

    's normative power than any other academic journal, including a special issue on "What Kind of Power?" in 2006. As the leading journal in the debate, this special issue brings together seven normative power articles published in JEPP since the 2006 special issue, together with Ian Manners' ‘Normative power......The social sciences have many different understandings of ‘normative power', but in European Union (EU) studies normative power has three particular meanings. The first meaning of normative power is its emphasis on normative theory, that is, how we judge and justify truth claims in social science...... effects of EU relations with the world in areas ranging from inter-regional relations, through traditional diplomacy, to environmental politics. Research areas of particular interest include the study of the interplay between physical, material and normative forms of power, as well as the constitutive...

  13. Power marketing

    International Nuclear Information System (INIS)

    Sioshansi, F.P.; Altman, A.M.

    1998-01-01

    One of the most significant developments in the US electric power industry in recent years has been the phenomenal growth of power marketing. What was barely a blimp on the radar screen in 1992 has turned out to be a jumbo jet. This article explains what is power marketing who are power marketers, what role play these players and what will be their longer-term impact on the traditional industry [it

  14. Power program and nuclear power

    International Nuclear Information System (INIS)

    Chernilin, Yu.F.

    1990-01-01

    Main points of the USSR power program and the role of nuclear power in fuel and power complex of the country are considered. Data on dynamics of economic indices of electric power generation at nuclear power plants during 1980-1988 and forecasts till 2000 are presented. It is shown that real cost of 1 kW/h of electric power is equal to 1.3-1.8 cop., and total reduced cost is equal to 1.8-2.4 cop

  15. Safety performance comparation of MOX, nitride and metallic fuel based 25-100 MWe Pb-Bi cooled long life fast reactors without on-site refuelling

    International Nuclear Information System (INIS)

    Su'ud, Zaki

    2008-01-01

    In this paper the safety performance of 25-100 MWe Pb-Bi cooled long life fast reactors based on three types of fuels: MOX, nitride and metal is compared and discussed. In the fourth generation NPP paradigm, especially for Pb-Bi cooled fast reactors, inherent safety capability is necessary against some standard accidents such as unprotected loss of flow (ULOF), unprotected rod run-out transient over power (UTOP), unprotected loss of heat sink (ULOHS). Selection of fuel type will have important impact on the overall system safety performance. The results of safety analysis of long life Pb-Bi cooled fast reactors without on-site fuelling using nitride, MOX and metal fuel have been performed. The reactors show the inherent safety pattern with enough safety margins during ULOF and UTOP accidents. For MOX fuelled reactors, ULOF accident is more severe than UTOP accident while for nitride fuelled cores UTOP accident may push power much higher than that comparable MOX fuelled cores. (author)

  16. Power Electronics

    Indian Academy of Sciences (India)

    They cover a wide spectrum of areas from power supplies to power system ... Ramanarayanan describe the modelling and design of a family of soft transition ... of power when the drive is operating in the braking mode and fast dynamic response. ... time models are extremely important, as they can be included in real time ...

  17. Power Outages

    Science.gov (United States)

    ... Publications Emergency Alerts Preparedness Portal Preparedness Messaging Calendar Social Media Preparedness Toolkits Preparedness News Languages About Us Build a Kit Close Search Enter Search Term(s): Main Content Home Be Informed Power Outages Power Outages Extended power outages may impact ...

  18. 76 FR 2145 - Masco Builder Cabinet Group Including On-Site Leased Workers From Reserves Network, Jackson, OH...

    Science.gov (United States)

    2011-01-12

    ...,287B; TA-W-71,287C] Masco Builder Cabinet Group Including On-Site Leased Workers From Reserves Network, Jackson, OH; Masco Builder Cabinet Group, Waverly, OH; Masco Builder Cabinet Group, Seal Township, OH; Masco Builder Cabinet Group, Seaman, OH; Amended Certification Regarding Eligibility To Apply for Worker...

  19. 75 FR 11920 - General Electric Lighting-Ravenna Lamp Plant, Lighting Division, Including On-Site Leased Workers...

    Science.gov (United States)

    2010-03-12

    ... to the production of high intensity discharge lamps. The review shows that on August 24, 2007, a...-Ravenna Lamp Plant, Lighting Division, Including On-Site Leased Workers from Devore Technologies, Ravenna..., 2009, applicable to workers of General Electric Lighting-Ravenna Lamp Plant, Lighting Division...

  20. 75 FR 28657 - Dell Products LP-Parmer North Location, a Subsidiary of Dell, Inc., Including On-Site Leased...

    Science.gov (United States)

    2010-05-21

    ... Spherion Corporation; Round Rock, TX; Dell Products LP--Parmer North One; Austin, TX; Amended Certification... Products LP--Parmer North Location, a Subsidiary of Dell, Inc., Including On-Site Leased Workers From... Act of 1974, as amended (``Act''), 19 U.S.C. 2273, the Department of Labor issued a Certification of...

  1. 75 FR 38127 - Visteon Systems, LLC North Penn Plant Electronics Products Group Including On-Site Leased Workers...

    Science.gov (United States)

    2010-07-01

    ..., North Penn Plant, Electronics Products Group to be covered by this certification. The intent of the... North Penn Plant Electronics Products Group Including On-Site Leased Workers From Ryder Integrated... Certification Regarding Eligibility To Apply for Worker Adjustment Assistance and Alternative Trade Adjustment...

  2. 75 FR 45160 - Ingersoll-Rand/Harrow Products, Inc., Formerly Known as Locknetics Including On-Site Leased...

    Science.gov (United States)

    2010-08-02

    ... account under the name Harrow Products, Inc. Accordingly, the Department is amending this certification to... Products, Inc., Formerly Known as Locknetics Including On-Site Leased Workers From Monroe Staffing Services, Adecco USA, Inc., and Infinistaff, LLC, Bristol, CT; Amended Certification Regarding Eligibility To Apply...

  3. 75 FR 51845 - Chrysler Group, LLC Manufacturing Division St. Louis North Plant Including On-Site Leased Workers...

    Science.gov (United States)

    2010-08-23

    ... produce performance coating solutions for vehicles. The company reports that workers leased from DuPont Performance Coatings, a wholly-owned subsidiary of E.I. DuPont de Nemours Company, OEM, were employed on-site..., C R Associates, Syncreon, Robinson Solutions and Dupont Performance Coatings Fenton, MO; Amended...

  4. 75 FR 20390 - Robert Bosch LLC, Including On-Site Leased Workers From Bosch Management Services North America...

    Science.gov (United States)

    2010-04-19

    ...-site leased workers of Bosch Management Services North America, South Haven Community Hospital... leased workers of Bosch Management Services North America, South Haven Community Hospital, Huffmaster Inc..., Including On-Site Leased Workers From Bosch Management Services North America, South Haven Community...

  5. 76 FR 27669 - Penske Logistics LLC, a Subsidiary of General Electric/Penske Corporation Including On-Site...

    Science.gov (United States)

    2011-05-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,897] Penske Logistics LLC, a Subsidiary of General Electric/Penske Corporation Including On-Site Leased Workers From Kelly Temporary... workers and former workers of Penske Logistics LLC, a subsidiary of General Electric/Penske Corporation...

  6. 76 FR 17447 - Penske Logistics LLC a Subsidiary of General Electric/Penske Corporation Including On-Site Leased...

    Science.gov (United States)

    2011-03-29

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,897] Penske Logistics LLC a Subsidiary of General Electric/Penske Corporation Including On-Site Leased Workers From Kelly Temporary... (TAA) applicable to workers and former workers of Penske Logistics LLC, a subsidiary of General...

  7. 76 FR 35025 - Nokia, Inc.; a Subsidiary of Nokia Group; Including On-Site Leased Workers From ATC Logistics and...

    Science.gov (United States)

    2011-06-15

    ... of Nokia Group; Including On-Site Leased Workers From ATC Logistics and Electronics and Adecco Fort... workers from ATC Logistics and Electronics, Fort Worth, Texas. The workers supplied planning and materials... ATC Logistics and Electronics, and Adecco, Fort Worth, Texas, who became totally or partially...

  8. 75 FR 11919 - Qimonda 200 MM Facility, Including On-Site Leased Workers From Tokyo Electron America, Nikon...

    Science.gov (United States)

    2010-03-12

    ... Qimonda AG Sandston, VA; Amended Certification Regarding Eligibility To Apply for Worker Adjustment..., Sandston, Virginia. The notice was published in the Federal Register on December 30, 2008 (73 FR 79914... division of Select Staffing were employed on-site at the Sandston, Virginia location of Qimonda 200MM...

  9. 75 FR 49525 - World Color (USA), LLC Formerly Known as Quebecor World World Color Covington Including On-Site...

    Science.gov (United States)

    2010-08-13

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,781] World Color (USA), LLC Formerly Known as Quebecor World World Color Covington Including On-Site Leased Workers From Randstad... Adjustment Assistance on May 14, 2010, applicable to workers of World Color (USA), LLC, formerly known as...

  10. 75 FR 16513 - B&C Corporation, JR Engineering Division, Including B&C Distribution Center, Including On-Site...

    Science.gov (United States)

    2010-04-01

    ... Engineering Division, Including B&C Distribution Center, Including On-Site Leased Workers From B&C Services... occurred during the relevant time period at the B&C Distribution Center, Inc. of the B&C Corporation, JR Engineering Division, Barberton, Ohio. The B&C Distribution Center provides distribution and logistical...

  11. 78 FR 42804 - Whirlpool Corporation, Including On-Site Leased Workers From Aerotek/Tek Systems (Subcontractor...

    Science.gov (United States)

    2013-07-17

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,346] Whirlpool Corporation, Including On-Site Leased Workers From Aerotek/Tek Systems (Subcontractor of IBM Corporation) and Jones Lang... firm. The workers were engaged in production of refrigerators and trash compactors as well as...

  12. 75 FR 77665 - Whirlpool Corporation, Including On-Site Leased Workers From Career Solutions TEC Staffing and...

    Science.gov (United States)

    2010-12-13

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,593] Whirlpool Corporation, Including On-Site Leased Workers From Career Solutions TEC Staffing and Andrews International, Fort Smith... subject firm. The workers are engaged in the production of refrigerators and trash compactors. The company...

  13. 76 FR 27365 - West, A Thomson Reuters Business, Thomson Reuters Legal Division, Including On-Site Leased...

    Science.gov (United States)

    2011-05-11

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,099] West, A Thomson Reuters Business, Thomson Reuters Legal Division, Including On-Site Leased Workers From ADECCO, Albuquerque, NM... Adjustment Assistance (TAA) applicable to workers and former workers of West, A Thomson Reuters Business...

  14. 76 FR 45879 - West, a Thomson Reuters Business, Thomson Reuters Legal, Including On-Site Leased Workers From...

    Science.gov (United States)

    2011-08-01

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,198] West, a Thomson Reuters Business, Thomson Reuters Legal, Including On-Site Leased Workers From Adecco, Including a Teleworker...-W-73,198 is hereby issued as follows: All workers of West, A Thomson Reuters Business, Thomson...

  15. 77 FR 6587 - PHB Die Casting a Subsidiary of PHB, Inc., Including On-Site Leased Workers From Career Concepts...

    Science.gov (United States)

    2012-02-08

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-64,292] PHB Die Casting a... 19, 2008, applicable to workers of PHB Die Casting, a subsidiary of PHB, Inc., including on-site... production of die castings. New information shows that a worker from Burns Industrial Group (BIG Inc) was...

  16. 76 FR 61740 - Geneon Entertainment (USA) Including On-Site Leased Workers From Interplace, Inc., Apple One and...

    Science.gov (United States)

    2011-10-05

    ...) Including On-Site Leased Workers From Interplace, Inc., Apple One and Robert Half Legal Santa Monica, CA...-site leased workers from Interplace, Inc., and Apple One, Santa Monica, California. The workers are... from Interplace, Inc., Apple One and Robert Half Legal, Santa Monica, California, who became totally or...

  17. 76 FR 29274 - Interstate Electronics Corp., a Subsidiary of L-3 Communications Including On-Site Leased Workers...

    Science.gov (United States)

    2011-05-20

    ... Resources, Systems Pros, Total Tech Services, Triple Crown Consulting, and Ingenium Technology, Inc... Resources, PDS Technical Service, Superior Technical Resources, Systems Pros, Total Tech Services, and... subject firm. The company reports that workers leased from Ingenium Technology, Inc. were employed on-site...

  18. 78 FR 40507 - Eastman Kodak Company, IPS, Including On-Site Leased Workers From Adecco, Dayton, Ohio; Notice of...

    Science.gov (United States)

    2013-07-05

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,813A] Eastman Kodak Company... Eastman Kodak Company, IPS, including on-site leased workers from Adecco, Dayton, Ohio (TA-W-74, 813A). At the request of Eastman Kodak Company, the Department reviewed the certification applicable to workers...

  19. 78 FR 66778 - Eastman Kodak Company, IPS-Dayton Location, Including On-Site Leased Workers From Adecco, Dayton...

    Science.gov (United States)

    2013-11-06

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,387] Eastman Kodak Company... workers of Eastman Kodak Company, IPS-Dayton Location, including on-site leased workers from Adecco, Dayton, Ohio (hereafter referred to as ``Eastman Kodak-IPS- Dayton''). On May 18, 2012, the Department...

  20. 76 FR 32227 - DST Systems, Inc., Including On-Site Leased Workers From Comsys Information Technology Services...

    Science.gov (United States)

    2011-06-03

    ..., Inc., Including On-Site Leased Workers From Comsys Information Technology Services, Megaforce, and Kelly Services Kansas City, MO; DST Technologies, a Wholly Owned Subsidiary of DST Systems, Inc., Boston... Information Technology Services, Megaforce, and Kelly Services, Kansas City, Missouri (subject firm). The...

  1. Evaluation of a loop-mediated isothermal amplification (LAMP) method for rapid on-site detection of horse meat

    NARCIS (Netherlands)

    Aartse, Aafke; Scholtens-Toma, Ingrid; A, van der Hans J.G.; Boersma-Greve, Monique M.; Prins, Theo W.; Ginkel, van Leen A.; Kok, Esther J.; Bovee, Toine F.H.

    2017-01-01

    Detection of horse DNA by loop-mediated isothermal amplification (LAMP) seems one of the most promising methods to meet the criteria of fast, robust, cost efficient, specific, and sensitive on-site detection. In the present study an assessment of the specificity and sensitivity of the LAMP horse

  2. 77 FR 17525 - Cinram Distribution, LLC, a Subsidiary of Cinram International Income Fund, Including On-Site...

    Science.gov (United States)

    2012-03-26

    ... International Income Fund had their wages reported through a separate unemployment insurance (UI) tax account..., a Subsidiary of Cinram International Income Fund, Including On-Site Leased Workers From Good People..., 2012, applicable to workers of Cinram Distribution, LLC, a subsidiary of Cinram International Income...

  3. 77 FR 19719 - Whirlpool Corporation Including On-Site Leased Workers From Career Solutions TEC Staffing, IBM...

    Science.gov (United States)

    2012-04-02

    ... Logistics, Eurest, Canteen, Kelly Services, Inc., Prodriver, Arkansas Warehouse, Inc., Andrews International... information shows that workers leased from Andrews International employed on-site at the Fort Smith, Arkansas...) tax account under the name U.S. Security. Accordingly, the Department is amending this certification...

  4. 75 FR 20390 - Senco Brands, Inc., fka Senco Products, Inc., Including the On-Site Leased Workers of Manpower...

    Science.gov (United States)

    2010-04-19

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-70,115] Senco Brands, Inc., fka... workers of Senco Brands, Inc., fka Senco Products, Inc., including the on-site leased workers of Manpower... Brands, Inc., fka Senco Products, Inc. The Department has determined that these workers were sufficiently...

  5. 75 FR 11914 - Chrysler, LLC, Mount Elliott Tool and Die, Including On-Site Leased Workers From Modern...

    Science.gov (United States)

    2010-03-12

    ... Elliott Tool and Die, Including On-Site Leased Workers From Modern Professional Services, TAC Automotive... Certification Regarding Eligibility To Apply for Worker Adjustment Assistance and Alternative Trade Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974 (19 U.S.C. 2273), and Section 246 of the...

  6. 76 FR 2710 - Pitney Bowes, Inc., Mailing Solutions Management Division Including On-Site Leased Workers of...

    Science.gov (United States)

    2011-01-14

    ...., Mailing Solutions Management Division Including On-Site Leased Workers of Guidant Group, and Teleworkers... Bowes, Inc., Mailing Solutions Management Division, Engineering Quality Assurance, Shelton, Connecticut... identity of the subject worker group. The worker group consists of workers of Pitney Bowes, Inc., the...

  7. 76 FR 66328 - Callaway Golf Ball Operations, Inc., Including On-Site Leased Workers From Reliable Temp Services...

    Science.gov (United States)

    2011-10-26

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-80,110] Callaway Golf Ball... Golf Ball Operations, Inc., including on-site leased workers from Reliable Temp Services, Inc., and... production of golf balls. The notice was published in the Federal Register on July 8, 2011 (76 FR 40401). At...

  8. 40 CFR 262.212 - Making the hazardous waste determination at an on-site interim status or permitted treatment...

    Science.gov (United States)

    2010-07-01

    ..., storage or disposal facility. If an eligible academic entity makes the hazardous waste determination... hazardous waste permit or interim status as soon as it arrives in the on-site treatment, storage or disposal... permitted treatment, storage or disposal facility. (e) If the unwanted material is a hazardous waste, the...

  9. 78 FR 42805 - HarperCollins Publishers Distribution Operations Including On-Site Leased Workers From Action...

    Science.gov (United States)

    2013-07-17

    ... Distribution Operations Including On- Site Leased Workers From Action Personnel, CGA Staffing Services, Dynamic... from Action Personnel, CGA Staffing Services, Dynamic Staffing, Kelly Services, and Manpower, Scranton... (Volume 78 FR Pages 28628-28630). At the request of the State Workforce Office, the Department reviewed...

  10. 77 FR 70477 - Verso Paper Corporation, Sartell Mill Division, Including On-Site Leased Workers From Securitas...

    Science.gov (United States)

    2012-11-26

    ..., Sartell Mill Division, Including On-Site Leased Workers From Securitas Security Services, Manpower, Inc..., applicable to workers and former workers of Verso Paper Corporation, Sartell Mill Division, Sartell... to TA-W-81,210 is hereby issued as follows: All workers of Verso Paper Corporation, Sartell Mill...

  11. 75 FR 20386 - Auburn Hosiery Mills, Inc., Currently Known as Delta Galil, Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-04-19

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,321] Auburn Hosiery Mills, Inc... Auburn Hosiery Mills, Inc., including on-site leased workers from Quality Personnel, Auburn, Kentucky... related to apparel. Information shows that Auburn Hosiery Mills was merged into its parent company, Delta...

  12. 77 FR 40637 - Smurfit-Stone Container Corporation, Containerboard Mill, Including On-Site Leased Workers From...

    Science.gov (United States)

    2012-07-10

    ... Corporation, Containerboard Mill, Including On-Site Leased Workers From KMW Enterprises and General Security... Assistance on May 6, 2010, applicable to workers of Smurfit-Stone Container Corporation, Containerboard Mill... Ontonagon, Michigan location of Smurfit-Stone Container Corporation, Containerboard Mill, Ontonagon...

  13. 75 FR 69471 - Smurfit-Stone Container Corporation, Containerboard Mill, Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-11-12

    ... Corporation, Containerboard Mill, Including On-Site Leased Workers From KMW Enterprises, Ontonagon, MI... to workers of Smurfit-Stone Container Corporation, Containerboard Mill, Ontonagon, Michigan. The... Ontonagon, Michigan location of Smurfit-Stone Container Corporation, Containerboard Mill. The Department has...

  14. 75 FR 26794 - International Paper Company Franklin Pulp & Paper Mill Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-05-12

    ... Company Franklin Pulp & Paper Mill Including On-Site Leased Workers From Railserve, Franklin, VA; Amended... workers of International Paper Company, Franklin Pulp & Paper Mill, Franklin, Virginia. The notice was... Pulp & Paper Mill. The Department has determined that these workers were sufficiently under the control...

  15. 77 FR 31643 - AI-Shreveport, LLC A Subsidiary of Android Industries Including On-Site Leased Workers From...

    Science.gov (United States)

    2012-05-29

    ... Subsidiary of Android Industries Including On-Site Leased Workers From Career Adventures, Inc. Shreveport..., 2011, applicable to workers of AI-Shreveport, LLC, a subsidiary of Android Industries, Shreveport...- Shreveport, LLC, a subsidiary of Android Industries. The amended notice applicable to TA-W-80,515 is hereby...

  16. 76 FR 79221 - Android Industries Belvidere, LLC, Including On-Site Leased Workers From QPS Employment Group...

    Science.gov (United States)

    2011-12-21

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,072] Android Industries..., 2010, applicable to workers of Android Industries Belvidere, LLC, including on-site leased workers from... Belvidere, Illinois location of Android Industries Belvidere, LLC. The Department has determined that these...

  17. 75 FR 11920 - Agilent Technologies, Eesof Division, Including On-Site Leased Workers From Volt and Managed...

    Science.gov (United States)

    2010-03-12

    ... workers of the subject firm. The workers are engaged in the production of electronic design automation software and related services including quality assurance and learning products, marketing, product development, marketing and administration. The company reports that on-site leased workers from Managed...

  18. 75 FR 11919 - Smith and Nephew, Inc., Wound Management-Largo Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-70,151] Smith and Nephew, Inc... November 5, 2009, applicable to workers of Smith and Nephew, Inc., Wound Management-Largo Division, Largo... workers leased from Adecco were employed on-site at the Largo, Florida location of Smith and Nephew, Inc...

  19. 77 FR 9969 - Johnson Controls D/B/A Hoover Universal, Inc. Including On-Site Leased Workers from Kelly...

    Science.gov (United States)

    2012-02-21

    ... Johnson Controls, including on-site leased workers from Kelly Services, Sycamore, Illinois. The notice was... amended notice applicable to TA-W-73,074 is hereby issued as follows: ''All workers of Johnston Controls... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,074] Johnson Controls D/B/A...

  20. 77 FR 63873 - Johnson Controls, Inc. Including On-Site Leased Workers of Valley Staffing and AZ Quality Hudson...

    Science.gov (United States)

    2012-10-17

    ... workers of Johnson Controls, Inc., including on-site leased workers from Valley Staffing, Hudson..., Wisconsin location of Johnson Controls, Inc. The Department has determined that these workers were sufficiently under the control of the subject firm to be considered leased workers. Based on these findings...

  1. 75 FR 28295 - Federal-Mogul, Including On-Site Leased Workers From Kelly Services, Summerton, SC; Amended...

    Science.gov (United States)

    2010-05-20

    ... workers were sufficiently under the control of the subject firm to be considered leased workers. Based on... On-Site Leased Workers From Kelly Services, Summerton, SC; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974...

  2. 77 FR 44685 - ConocoPhillips Company, Trainer Refinery, Including On-Site Leased Workers From Shrack, Young...

    Science.gov (United States)

    2012-07-30

    ..., Trainer Refinery, Including On-Site Leased Workers From Shrack, Young, and Associates, Inc., and Project Control Associates, Trainer, PA; Notice of Revised Determination on Reconsideration On April 30, 2012, the... applicable to workers and former workers of ConocoPhillips Company, Trainer Refinery, Trainer, Pennsylvania...

  3. 77 FR 61028 - Hasbro, Inc.; Hasbro Managerial Services, Inc., Including On-Site Leased Workers of Entegee East...

    Science.gov (United States)

    2012-10-05

    ... relevant period and that the subject firm had sufficient control over the leased workers for the Department to determine that there was operational control of the leased workers by the subject firm. The... Managerial Services, Inc., Including On-Site Leased Workers of Entegee East Longmeadow, MA Amended...

  4. 75 FR 66797 - Watts Regulator, Including On-Site Leased Workers From Employment Control, D/B/A Employment...

    Science.gov (United States)

    2010-10-29

    ..., Including On-Site Leased Workers From Employment Control, D/B/A Employment Staffing, Inc., Spindale, NC; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with... a Certification of Eligibility to Apply for Worker Adjustment Assistance on May 27, 2010, applicable...

  5. 75 FR 69470 - JL French Automotive Castings, LLC, Including On-Site Leased Workers From Labor Ready and Seek...

    Science.gov (United States)

    2010-11-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-70,143] JL French Automotive... workers of JL French Automotive Castings LLC, including on-site leased workers Labor Ready, Sheboygan... Sheboygan, Wisconsin location of JL French Automotive Castings LLC. The Department has determined that these...

  6. 75 FR 43556 - Badger Meter, Inc., Including On-Site Leased Workers From Sourcepoint Staffing, Seek, and...

    Science.gov (United States)

    2010-07-26

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,666] Badger Meter, Inc... of Badger Meter, Inc., including on-site leased workers from Sourcepoint Staffing, Milwaukee... workers are engaged in the production of flow measurement devices and automatic meter reading equipment...

  7. 77 FR 70478 - RG Steel Wheeling, LLC, Wheeling Office, A Division Of RG Steel, LLC, Including On-Site Leased...

    Science.gov (United States)

    2012-11-26

    ... Unlimited and Green Energy Initiatives LLC, Including Workers Whose Wages Were Reported Through Severstal..., Wheeling Office, a division of RG Steel, LLC, including on-site leased workers from Pro Unlimited and Green Energy Initiatives, LLC, Wheeling, West Virginia (TA-W-81,880) and Mountain State Carbon, LLC, including...

  8. 75 FR 20382 - Chrysler LLC, St. Louis North Assembly Plant, Including On-Site Leased Workers From HAAS TCM, Inc...

    Science.gov (United States)

    2010-04-19

    ...., Diversified Contract Service, Inc. 639, and Logistics Management Services, Inc., Fenton, MO; Amended... Logistics Management Services, Inc. worked on-site at the Chrysler LLC, Fenton, Missouri plant (Logistics... Department is amending this certification to include workers leased from Logistics Management Services, Inc...

  9. 75 FR 20384 - Chrysler LLC, St. Louis North Assembly Plant, Including On-Site Leased Workers From Haas TCM, Inc...

    Science.gov (United States)

    2010-04-19

    .... Diversified Contract Service, Inc. 639, and Logistics Management Services, Inc. Fenton, MO; Amended... Logistics Management Services, Inc. worked on-site at the Chrysler LLC, Fenton, Missouri plant (Logistics... Department is amending this certification to include workers leased from Logistics Management Services, Inc...

  10. 75 FR 22627 - Chrysler LLC, St. Louis North Assembly Plant Including On-Site Leased Workers From HAAS TCM, Inc...

    Science.gov (United States)

    2010-04-29

    ... North Assembly Plant Including On-Site Leased Workers From HAAS TCM, Inc., Logistics Services, Inc., Robinson Solutions, Logistics Management Services, Inc., Corrigan Company and Murphy Company, Fenton, MO... workers from HAAS TCM, Inc., Logistics Services, Inc., Robinson Solutions, Logistics Management Services...

  11. 75 FR 11918 - General Electric Kentucky Glass Plant, Lighting, LLC, Including On-Site Leased Workers From the...

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,011] General Electric Kentucky Glass Plant, Lighting, LLC, Including On-Site Leased Workers From the Patty Tipton Company, Aetna Building Maintenance, and Concentra, Lexington, KY; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordanc...

  12. 76 FR 16447 - Lafarge North America, Inc., a Subsidiary of Lafarge, Including On-Site Leased Workers From...

    Science.gov (United States)

    2011-03-23

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,880] Lafarge North America, Inc., a Subsidiary of Lafarge, Including On-Site Leased Workers From Industrial Services, Incorporated and Summit Building Maintenance, Seattle, WA; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance...

  13. A Study on the Reliability of an On-Site Oral Fluid Drug Test in a Recreational Context

    Directory of Open Access Journals (Sweden)

    Stefano Gentili

    2016-01-01

    Full Text Available The reliability of DrugWipe 5A on site test for principal drugs of abuse (cannabis, amphetamines, cocaine, and opiates detection in oral fluid was assessed by comparing the on-site results with headspace solid-phase microextraction (HS-SPME gas chromatography-mass spectrometry (GC-MS analysis on samples extracted by the device collection pad. Oral fluid samples were collected at recreational settings (e.g., discos, pubs, and music bars of Rome metropolitan area. Eighty-three club goers underwent the on-site drug screening test with one device. Independently from the result obtained, a second device was used just to collect another oral fluid sample subsequently extracted and analyzed in the laboratory following HS-SPME procedure, gas chromatographic separation by a capillary column, and MS detection by electron impact ionization. DrugWipe 5A on-site test showed 54 samples (65.1% positive to one or more drugs of abuse, whereas 75 samples (90.4% tested positive for one or more substances following GC-MS assay. Comparing the obtained results, the device showed sensitivity, specificity, and accuracy around 80% for amphetamines class. Sensitivity (67 and 50% was obtained for cocaine and opiates, while both sensitivity and accuracy were unsuccessful (29 and 53%, resp. for cannabis, underlying the limitation of the device for this latter drug class.

  14. 78 FR 37586 - TE Connectivity, CIS-Appliances Division, Including On-Site Leased Workers From Kelly Services...

    Science.gov (United States)

    2013-06-21

    ... supply of administrative support services (in support of production). The worker group includes on-site... components produced by the subject workers. Further, aggregate imports of articles like or directly... reconsideration, the worker supplied new information regarding a possible shift in the production of like or...

  15. 78 FR 21151 - Boise White Paper, LLC, A Subsidiary of Boise Paper Holdings, LLC, Including On-Site Leased...

    Science.gov (United States)

    2013-04-09

    ... Paper, LLC, A Subsidiary of Boise Paper Holdings, LLC, Including On-Site Leased Workers From Guardsmark.... Helens, OR; Boise White Paper, LLC, A Subsidiary of Boise Paper Holdings, LLC, Vancouver, WA; Amended... workers and former workers of Boise White Paper, LLC, a subsidiary of Boise Paper Holdings, LLC, St...

  16. 75 FR 38129 - Freescale Semiconductor, Inc., Hardware/Software Design and Manufacturing A Including On-Site...

    Science.gov (United States)

    2010-07-01

    ... Manufacturing A, Austin, Texas. The notice was published in the Federal Register on May 28, 2010 (75 FR 30070...Logic, Inc., Austin, TX; Amended Certification Regarding Eligibility To Apply for Worker Adjustment..., Design Solutions, Inc., Veriseo, SilconElite and MicroLogic, Inc. were employed on-site at the Austin...

  17. 77 FR 19718 - Ford Motor Company Twin Cities Assembly Plant Vehicle Operations Division Including On-Site...

    Science.gov (United States)

    2012-04-02

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,038] Ford Motor Company Twin... February 9, 2012, applicable to workers of Ford Motor Company, Twin Cities Assembly Plant, Vehicle..., and Pacer International were employed on-site at the St. Paul, Minnesota location of Ford Motor...

  18. Design/licensing of on-site package for core component

    International Nuclear Information System (INIS)

    Ogasawara, K.; Chohzuka, T.; Shimura, T.; Kikuchi, T.; Fujiwara, R.; Karigome, S.; Takani, M.

    1993-01-01

    For storage of used core components which are produced from reactors, Tohoku EPCO decided to construct a site bunker at Onagawa site. It was also decided to develop and fabricate one packaging to transport core components from the reactor buildings to the site bunker. The packaging will be used within the power station; therefore, it shall comply with 'The Law for the Business of Electric Power' and relevant Notification. The main requirements of the packaging are as follows: 1) The number of contents, such as channel boxes and control rods, shall be as large as possible. 2) The weight and the outer dimensions of the packaging shall be within the limitation of the reactor building and the site bunker. 3) Materials shall be selected from those which have been already applied for existing packagings and utilized without any problems. 4) It shall be considered during design of trunnions that handling equipment, such as lifting beam, can be used for not only this packaging but also for existing spent fuel packagings. The design of the packaging is completed and has been licensed. The packaging is scheduled to be utilized from November, 1993. (J.P.N.)

  19. The future for distributed power in Asia

    International Nuclear Information System (INIS)

    Kanwarpal, Vishvjeet

    2000-01-01

    The substantial potential market opportunities for on-site tailor-made cogeneration units in Asia generally is discussed. The article also looks at India, Australia, Japan and Indonesia in particular. The article is presented under the sub-headings of (i) Asian power and IPP developments; (ii) captive capacity and rationale; (iii) Asian captive capacity; (iv) captive power plants; (v) key drivers of CPPs in Asia; (vi) cogeneration plants; (vii) cogeneration application industries; (viii) biomass power for Asia (ix) key hurdles in cogeneration development; (x) future potential of cogeneration and (xi) country snapshots

  20. Georgia Power Company's college degree program

    International Nuclear Information System (INIS)

    Coggin, C.L.

    1988-01-01

    The purpose of this paper is to describe Georgia Power Company's on-site college degree program for nuclear power plant personnel. In February 1986, the US Nuclear Regulatory Commission issued a policy statement concerning engineering expertise on shift (Generic Letter 86-04), which appeared in Volume 50, Number 208 of the October 28, 1985 Federal Register. One of the options available to nuclear power plant personnel to meet the requirement was the combined senior reactor operator/shift technical adviser position. One of the methods for meeting the option included a bachelor's degree in engineering technology for an accredited institution, including course work in the physical, mathematical, or engineering sciences

  1. Thin layer chromatography coupled with surface-enhanced Raman scattering as a facile method for on-site quantitative monitoring of chemical reactions.

    Science.gov (United States)

    Zhang, Zong-Mian; Liu, Jing-Fu; Liu, Rui; Sun, Jie-Fang; Wei, Guo-Hua

    2014-08-05

    By coupling surface-enhanced Raman spectroscopy (SERS) with thin layer chromatography (TLC), a facile and powerful method was developed for on-site monitoring the process of chemical reactions. Samples were preseparated on a TLC plate following a common TLC procedure, and then determined by SERS after fabricating a large-area, uniform SERS substrate on the TLC plate by spraying gold nanoparticles (AuNPs). Reproducible and strong SERS signals were obtained with substrates prepared by spraying 42-nm AuNPs at a density of 5.54 × 10(10) N/cm(2) on the TLC plate. The capacity of this TLC-SERS method was evaluated by monitoring a typical Suzuki coupling reaction of phenylboronic acid and 2-bromopyridine as a model. Results showed that this proposed method is able to identify reaction product that is invisible to the naked eye, and distinguish the reactant 2-bromopyridine and product 2-phenylpyridine, which showed almost the same retention factors (R(f)). Under the optimized conditions, the peak area of the characteristic Raman band (755 cm(-1)) of the product 2-phenylpyridine showed a good linear correlation with concentration in the range of 2-200 mg/L (R(2) = 0.9741), the estimated detection limit (1 mg/L 2-phenylpyridine) is much lower than the concentration of the chemicals in the common organic synthesis reaction system, and the product yield determined by the proposed TLC-SERS method agreed very well with that by UPLC-MS/MS. In addition, a new byproduct in the reaction system was found and identified through continuous Raman detection from the point of sample to the solvent front. This facile TLC-SERS method is quick, easy to handle, low-cost, sensitive, and can be exploited in on-site monitoring the processes of chemical reactions, as well as environmental and biological processes.

  2. The Potential in Water Supply and Sanitation Services of the On Site Production of Sodium Hypochlorite (OSEC Driven by PV Solar Source

    Directory of Open Access Journals (Sweden)

    Andrea Micangeli

    2013-12-01

    Full Text Available This study aims at evaluating the impact of an On Site Electro Chlorination (OSEC device, a system for the sodium hypochlorite production, on the improvement of health and hygienic standards in Mesoamerica focusing on Chiapas-Mexico and Costa Rica, as well as in Africa, Western Sahara (Refugees Camp and Tanzania. The threat of infectious diseases and the importance of cleaned and treated water with the consequent high impact on the vulnerable population have been studied in each of the above countries. In this framework the production of low cost sodium hypochlorite through a stand-alone system powered by PV solar source could be a good starting point in improving sanitation conditions, assuring the disinfection of water and clothes, and improve food safety. The cost analysis shows that producing sodium hypochlorite with an OSEC solar system could lead to 10 to 15 times saving with respect to the purchasing of it at market price, above all in developing countries. Furthermore, the LCA study highlights the low environmental impact of the on-site production of sodium hypochlorite through qualitative and quantitative data that demonstrate how this system has pollutant emissions from 14 to 56 times lower than the equivalent industrial process (N factor. The paper describes as well possible practical applications of the sodium hypochlorite in the African and Latin American context. Additionally, it demonstrates the potential to create an impact on the social context and microenterprises specialised in the production of hygiene and sanitation products, managed by local people selling at affordable prices and reaching the poorest villages of developing countries.

  3. Nuclear Power

    International Nuclear Information System (INIS)

    Douglas-Hamilton, J.; Home Robertson, J.; Beith, A.J.

    1987-01-01

    In this debate the Government's policy on nuclear power is discussed. Government policy is that nuclear power is the safest and cleanest way of generating electricity and is cheap. Other political parties who do not endorse a nuclear energy policy are considered not to be acting in the people's best interests. The debate ranged over the risks from nuclear power, the UK safety record, safety regulations, and the environmental effects of nuclear power. The Torness nuclear power plant was mentioned specifically. The energy policy of the opposition parties is strongly criticised. The debate lasted just over an hour and is reported verbatim. (UK)

  4. Lessons learned -- a comparison of the proposed on-site waste management facilities at the various Department of Energy sites

    International Nuclear Information System (INIS)

    Ciocco, J.; Singh, D.; Survochak, S.; Elo, M.

    1996-01-01

    The Department of Energy Sites (DOE) are faced with the challenge of managing several categories of waste generated from past or future cleanup activities, such as 11(e)2 byproduct material, low-level radioactive (LL), low-level radioactive mixed (LLM), transuranic (TRU), high level radioactive (HL), and hazardous waste (HW). DOE must ensure safe and efficient management of these wastes while complying with all applicable federal and state laws. Proposed waste management strategies for the EM-40 Environmental Restoration (ER) program at these sites indicate that on-site disposal is becoming a viable option. For purposes of this paper, on-site disposal cells managed by the EM-40 program at Hanford, Weldon Spring, Fernald Environmental Management Project (FEMP) and Rocky Flats were compared. Programmatic aspects and design features were evaluated to determine what comparisons can be made, and to identify benefits lessons learned that may be applicable to other sites. Based on comparative analysis, it can be concluded that the DOE EM-40 disposal cells are very unique. Stakeholders played a major role in the decision to locate the various DOE on-site disposal facilities. The disposal cells will be used to manage 11(e)2 by-product materials, LL, LLM, and/or HLW. The analysis further suggests that the design criteria are comparable. Lessons learned relative to the public involvement activities at Weldon Spring, and the design approach at Hanford should be considered when planning future on-site disposal facilities at DOE sites. Further, a detailed analysis of progress made at Hanford should be evaluated for application at sites such as Rocky Flats that are currently planning on-site disposal facilities

  5. Training courses on neutron detection systems on the ISIS research reactor: on-site and through internet training

    Energy Technology Data Exchange (ETDEWEB)

    Lescop, B.; Badeau, G.; Ivanovic, S.; Foulon, F. [National Institute for Nuclear science and Technology French Atomic Energy and Alternative Energies Commission (CEA), Saclay Research Center, 91191 Gif-sur-Yvette (France)

    2015-07-01

    Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. The facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10{sup 12} n/cm{sup 2}.s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also

  6. Training courses on neutron detection systems on the ISIS research reactor: on-site and through internet training

    International Nuclear Information System (INIS)

    Lescop, B.; Badeau, G.; Ivanovic, S.; Foulon, F.

    2015-01-01

    Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. The facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10 12 n/cm 2 .s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also modify the

  7. Primer on Use of Multi-Spectral and Infra Red Imaging for On-Site Inspections

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, J R

    2010-10-26

    The purpose of an On-Site Inspection (OSI) is to determine whether a nuclear explosion has occurred in violation of the Comprehensive Nuclear Test Ban Treaty (CTBT), and to gather information which might assist in identifying the violator (CTBT, Article IV, Paragraph 35) Multi-Spectral and Infra Red Imaging (MSIR) is allowed by the treaty to detect observables which might help reduce the search area and thus expedite an OSI and make it more effective. MSIR is permitted from airborne measurements, and at and below the surface to search for anomalies and artifacts (CTBT, Protocol, Part II, Paragraph 69b). The three broad types of anomalies and artifacts MSIR is expected to be capable of observing are surface disturbances (disturbed earth, plant stress or anomalous surface materials), human artifacts (man-made roads, buildings and features), and thermal anomalies. The purpose of this Primer is to provide technical information on MSIR relevant to its use for OSI. It is expected that this information may be used for general background information, to inform decisions about the selection and testing of MSIR equipment, to develop operational guidance for MSIR use during an OSI, and to support the development of a training program for OSI Inspectors. References are provided so readers can pursue a topic in more detail than the summary information provided here. The following chapters will provide more information on how MSIR can support an OSI (Section 2), a short summary what Multi-Spectral Imaging and Infra Red Imaging is (Section 3), guidance from the CTBT regarding the use of MSIR (Section 4), and a description of several nuclear explosion scenarios (Section 5) and consequent observables (Section 6). The remaining sections focus on practical aspects of using MSIR for an OSI, such as specification and selection of MSIR equipment, operational considerations for deployment of MISR equipment from an aircraft, and the conduct of field exercises to mature MSIR for an OSI

  8. Influence of Palythoa caribaeorum (Anthozoa, Cnidaria zonation on site-attached reef fishes

    Directory of Open Access Journals (Sweden)

    José P. Mendonça-Neto

    2008-09-01

    Full Text Available This work aimed to test the influence of Palythoa caribeorum, a widely distributed zoanthid in the Atlantic, on site-attached reef fish in a subtropical rocky shore. Density, richness and vertical distribution of reef fish inside (ID and outside (OD previously chosen P. caribaeorum dominance patches were compared through stationary visual censuses along three different periods. Fishes were grouped in different trophic guilds to evidence differences in resources uses in both treatments. A complexity index was estimated by the chain link method and percentage covering of benthic organisms was obtained analyzing random points from replicated photo-quadrats. We observed thirty-eight species of fishes, belonging to twenty-five families. Reef fish communities between studied patches were similar,both in terms of species composition and vertical distribution. Considering only the most site-attached fishes, which were the most frequent and abundant species, data showed that ID sustains higher diversity and abundance than OD. Results showed that benthic composition differ significantly among patches whereas complexity remained without differences. Otherwise, results indicated that these areas might play an important role in space limitation, structuring neighboring benthic community and consequently reef fish assemblages.Este estudo visou testar a influência de Palythoa caribeorum, um zoantídeo amplamente distribuído no Atlântico, na estruturação da comunidade de peixes recifais associados a um costão rochoso de uma região subtropical. A densidade, a riqueza e a distribuição vertical de peixes recifais em áreas previamente selecionadas com e sem a dominância de Palythoa caribaeorum foram comparadas através de censos visuais estacionários em três períodos distintos de tempo. Os peixes foram agrupados em guildas tróficas a fim de evidenciar diferenças nos usos dos recursos nas diferentes áreas analisadas. Foram analisados também

  9. International workshop on site investigation and evaluation based on the siting process in Sweden

    International Nuclear Information System (INIS)

    Andersson, Johan; Stroem, A.

    2001-06-01

    SKB's goal is to commence surface based site investigations in 2002. Extensive preparations are now being made for this transition to the next phase in the siting process for the deep repository for spent nuclear fuel. The purpose of the international workshop on site characterisation held at Aespoe April 2001 was to: present the SKB site investigation and evaluation programme to a group of international experts; discuss whether the available toolbox of investigation methods for surface based site investigations is appropriate and state-of-the-art in an international perspective; and by working group sessions discuss the level of ambition in the programme for site investigation for each discipline. This report summarises the conclusions of the workshop in general terms. Many of the detailed comments and ideas obtained at the workshop have already inspired and will also directly inspire the on-going planning work for site characterisation. The core activity at the workshop was the work performed by working groups. They addressed what should be considered for a site characterisation programme, based on the generic planning made so far by SKB. The working groups also outlined site specific characterisation programmes for the sites suggested by SKB. The tasks were strictly confined to technical and scientific modelling issues. The working group chairmen presented the working group results at the workshop and have also submitted short memos to SKB. The present document is a compilation of these memos. The SKB generic programme as presented in the existing top level documents, 'Requirements and Criteria and Overall Programme', received general endorsement and was appreciated for being comprehensive and systematic. For example, it contains comprehensive lists of parameters to be measured. However, there is need for prioritisation and sequencing. This is actually included in the current planning process at SKB where the generic programme later this year will be adapted to

  10. Power Talk

    DEFF Research Database (Denmark)

    Angjelichinoski, Marko; Stefanovic, Cedomir; Popovski, Petar

    2016-01-01

    A standard way to realize communication in microgrid control is to use an external communication network, such as modems for wireless or power-line communication, whose implementation may be inefficient in terms of deployment cost, complexity, and system stability. In this chapter we present......, while its reliability and availability draw on the reliability and availability of the microgrid power transmission system....... a communication solution, denoted as power talk, which is solely based on the use of the existing microgrid power equipment (i.e., power electronics and buses). The pivotal idea is to modulate information in the power-related parameters of the microgrid buses by use of the flexibility of power electronic...

  11. Nuclear power

    International Nuclear Information System (INIS)

    Porter, Arthur.

    1980-01-01

    This chapter of the final report of the Royal Commission on Electric Power Planning in Ontario updates its interim report on nuclear power in Ontario (1978) in the light of the Three Mile Island accident and presents the commission's general conclusions and recommendations relating to nuclear power. The risks of nuclear power, reactor safety with special reference to Three Mile Island and incidents at the Bruce generating station, the environmental effects of uranium mining and milling, waste management, nuclear power economics, uranium supplies, socio-political issues, and the regulation of nuclear power are discussed. Specific recommendations are made concerning the organization and public control of Ontario Hydro, but the commission concluded that nuclear power is acceptable in Ontario as long as satisfactory progress is made in the disposal of uranium mill tailings and spent fuel wastes. (LL)

  12. Stockholm Power Tech. Power systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The proceedings from this symposium is presented in six volumes: Invited speakers` sessions; Power systems; Power electronics; High-voltage technology; Electrical machines and drives; and Information and control systems. This report covers the power systems volume. Separate abstracts have been prepared for 141 of the 145 papers in this volume

  13. Stockholm Power Tech. Power systems

    International Nuclear Information System (INIS)

    1995-01-01

    The proceedings from this symposium is presented in six volumes: Invited speakers' sessions; Power systems; Power electronics; High-voltage technology; Electrical machines and drives; and Information and control systems. This report covers the power systems volume. Separate abstracts have been prepared for 141 of the 145 papers in this volume

  14. Application of ultra-sons to on-site spent fuel assemblies metrology

    International Nuclear Information System (INIS)

    Gondard, C.; Saglio, R.; Vouillot, M.; Delaroche, P.; Vaubert, Y.; Van Craeynest, J.C.

    1983-12-01

    Fuel assemblies inspection on the site of a power reactor, between two irradiation campaigns, allows to estimate the behaviour of prototype fuel assemblies and to permit their refueling for the continuation of the irradiation; the utilization of non-destructive, reliable and high-performance techniques, is of a great interest in the application. For, this reason, the C.E.A. has been led to carry out new techniques allowing the visual examination and the dimensional inspection of spent fuel assemblies of 900 MWe French pressurized water reactors, with a transportable Fuel Examination Module (MEC) on every reactor site. This module includes a television camera, and uses for the first time as ''position sensor'' the properties offered by a set of ultrasonic transducers. The main principle of the design, of the operation way of the module, of the measuring methods, and, of the data acquisition and processing, are presented [fr

  15. Evaluation of Approaches for Managing Nitrate Loading from On-Site Wastewater Systems near La Pine, Oregon

    Science.gov (United States)

    Morgan, David S.; Hinkle, Stephen R.; Weick, Rodney J.

    2007-01-01

    This report presents the results of a study by the U.S. Geological Survey, done in cooperation with the Oregon Department of Environmental Quality and Deschutes County, to develop a better understanding of the effects of nitrogen from on-site wastewater disposal systems on the quality of ground water near La Pine in southern Deschutes County and northern Klamath County, Oregon. Simulation models were used to test the conceptual understanding of the system and were coupled with optimization methods to develop the Nitrate Loading Management Model, a decision-support tool that can be used to efficiently evaluate alternative approaches for managing nitrate loading from on-site wastewater systems. The conceptual model of the system is based on geologic, hydrologic, and geochemical data collected for this study, as well as previous hydrogeologic and water quality studies and field testing of on-site wastewater systems in the area by other agencies. On-site wastewater systems are the only significant source of anthropogenic nitrogen to shallow ground water in the study area. Between 1960 and 2005 estimated nitrate loading from on-site wastewater systems increased from 3,900 to 91,000 pounds of nitrogen per year. When all remaining lots are developed (in 2019 at current building rates), nitrate loading is projected to reach nearly 150,000 pounds of nitrogen per year. Low recharge rates (2-3 inches per year) and ground-water flow velocities generally have limited the extent of nitrate occurrence to discrete plumes within 20-30 feet of the water table; however, hydraulic-gradient and age data indicate that, given sufficient time and additional loading, nitrate will migrate to depths where many domestic wells currently obtain water. In 2000, nitrate concentrations greater than 4 milligrams nitrogen per liter (mg N/L) were detected in 10 percent of domestic wells sampled by Oregon Department of Environmental Quality. Numerical simulation models were constructed at transect (2

  16. Local sharing of cogeneration energy through individually prioritized controls for increased on-site energy utilization

    International Nuclear Information System (INIS)

    Hirvonen, Janne; Kayo, Genku; Hasan, Ala; Sirén, Kai

    2014-01-01

    Highlights: • Sharing of surplus heat and electricity produced by CHP plants in different types of buildings. • Individually prioritized control of CHP plants with direct local sharing and minimal storage capacity. • Energy sharing reduced primary energy consumption by 1–9% with biogas. • Excess energy minimized by thermal tracking. - Abstract: All over the world, including Japan, there are targets to decrease building energy consumption and increase renewable energy utilization. Combined heat and power (CHP) plants increase energy efficiency and are becoming popular in Japan. CHP plants produce both heat and power simultaneously, but there is not always a need for both. A cluster of several different buildings can increase total efficiency and reduce primary energy (PE) consumption by sharing excess heat and electricity between neighboring buildings. If the generated energy comes from renewable sources, energy sharing makes it easier to reach the net zero energy balance. By adjusting CHP sizes and operation patterns, the wasted heat and primary energy consumption can be minimized. Energy sharing has been explored in situations with identical buildings and centrally administered energy systems before, but not with different building types with separate systems. In this study, a cluster of Japanese office and residential buildings were combined to allow heat and electricity sharing based on cogeneration, using individually prioritized control (IPC) systems. TRNSYS simulation was used to match energy generation with pregenerated demand profiles. Absorption cooling was utilized to increase the benefits of local heat generation. Different CHP operation modes and plant sizes were tested. The benefit of surplus energy sharing depends on the CHP capacities and the fuel type. When using biogas, larger CHP plants provided lower total primary energy consumption, in the most extreme case lowering it by 71%, compared to the conventional case. Using natural gas

  17. Nuclear power

    International Nuclear Information System (INIS)

    King, P.

    1990-01-01

    Written from the basis of neutrality, neither for nor against nuclear power this book considers whether there are special features of nuclear power which mean that its development should be either promoted or restrained by the State. The author makes it dear that there are no easy answers to the questions raised by the intervention of nuclear power but calls for openness in the nuclear decision making process. First, the need for energy is considered; most people agree that energy is the power to progress. Then the historicalzed background to the current position of nuclear power is given. Further chapters consider the fuel cycle, environmental impacts including carbon dioxide emission and the greenhouse effect, the costs, safety and risks and waste disposal. No conclusion either for or against nuclear power is made. The various shades of opinion are outlined and the arguments presented so that readers can come to their own conclusions. (UK)

  18. Cyber Power

    Science.gov (United States)

    2010-05-01

    government. Another way of looking at power in the cyber domain is to consider the three faces or aspects of relational power. 1st Face: (A induces B do...power. For example, on the February 2010 anniversary of the Iranian Revolution, the government slowed the internet to prevent protesters sending films ...all but a few government controlled Web sites. The damage to business and tourism was significant, but the Chinese government was more concerned

  19. Star power

    International Nuclear Information System (INIS)

    Kennedy, Tom

    2003-01-01

    Discusses the fight over the diminishing supply of fossil fuels and how there could be an unlimited, clean and politically free source of power just over the horizon. Fusion was discovered as a much better, inexhaustable supply of power, it only takes a few atoms to fuse for fusion to take off. Fusion once started will continue until all the fuel is exhausted. It is expected, that with the current rate of progess, in fifty years time scientists will achieve practical fusion power

  20. Verification of criticality safety in on-site spent fuel storage systems

    International Nuclear Information System (INIS)

    Rasmussen, R.W.

    1989-01-01

    On February 15, 1984, Duke Power Company received approval for a two-region, burnup credit, spent fuel storage rack design at both Units 1 and 2 of the McGuire Nuclear Station. Duke also hopes to obtain approval by January of 1990 for a dry spent fuel storage system at the Oconee Nuclear Station, which will incorporate the use of burnup credit in the criticality analysis governing the design of the individual storage units. While experiences in burnup verification for criticality safety for their dry storage system at Oconee are in the future, the methods proposed for burnup verification will be similar to those currently used at the McGuire Nuclear Station in the two-region storage racks installed in both pools. In conclusion, the primary benefit of the McGuire rerack effort has obviously been the amount of storage expansion it provided. A total increase of about 2,000 storage cells was realized, 1,000 of which were the result of pursuing the two-region rather than the conventional poison rack design. Less impacting, but equally as important, however, has been the experience gained during the planning, installation, and operation of these storage racks. This experience should prove useful for future rerack efforts likely to occur at Duke's Catawba Nuclear Station as well as for the current dry storage effort underway for the Oconee Nuclear Station

  1. On-site installation and shielding of a mobile electron accelerator for radiation processing

    International Nuclear Information System (INIS)

    Catana, D.; Panaitescu, J.; Axinescu, S.; Manolache, D.; Matei, C.; Corcodel, C.; Ulmeanu, M..; Bestea, V.

    1995-01-01

    The development of radiation processing of some bulk products, e.g. grains or potatoes, would be sustained if the irradiation had been carried out at the place of storage, i.e. silo. A promising solution is proposed consisting of a mobile electron accelerator, installed on a couple of trucks and traveling from one customer to another. The energy of the accelerated electrons was chosen at 5 MeV, with 10 to 50 kW beam power. The irradiation is possible either with electrons or with bremsstrahlung. A major problem of the above solution is the provision of adequate shielding at the customer, with a minimum investment cost. Plans for a bunker are presented, which houses the truck carrying the radiation head. The beam is vertical downwards, through the truck floor, through a transport pipe and a scanning horn. The irradiation takes place in a pit, where the products are transported through a belt. The belt path is so chosen as to minimize openings in the shielding. Shielding calculations are presented supposing a working regime with 5 MeV bremsstrahlung. Leakage and scattered radiation are taken into account. (orig.)

  2. On-site installation and shielding of a mobile electron accelerator for radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Catana, D. [Institutul de Fizica Atomica, Bucharest (Romania); Panaitescu, J. [Institutul de Fizica Atomica, Bucharest (Romania); Axinescu, S. [Institutul de Fizica Atomica, Bucharest (Romania); Manolache, D. [Institutul de Fizica Atomica, Bucharest (Romania); Matei, C. [Institutul de Fizica Atomica, Bucharest (Romania); Corcodel, C. [Institutul de Fizica Atomica, Bucharest (Romania); Ulmeanu, M.. [Institutul de Fizica Atomica, Bucharest (Romania); Bestea, V. [Institutul de Fizica Atomica, Bucharest (Romania)

    1995-05-01

    The development of radiation processing of some bulk products, e.g. grains or potatoes, would be sustained if the irradiation had been carried out at the place of storage, i.e. silo. A promising solution is proposed consisting of a mobile electron accelerator, installed on a couple of trucks and traveling from one customer to another. The energy of the accelerated electrons was chosen at 5 MeV, with 10 to 50 kW beam power. The irradiation is possible either with electrons or with bremsstrahlung. A major problem of the above solution is the provision of adequate shielding at the customer, with a minimum investment cost. Plans for a bunker are presented, which houses the truck carrying the radiation head. The beam is vertical downwards, through the truck floor, through a transport pipe and a scanning horn. The irradiation takes place in a pit, where the products are transported through a belt. The belt path is so chosen as to minimize openings in the shielding. Shielding calculations are presented supposing a working regime with 5 MeV bremsstrahlung. Leakage and scattered radiation are taken into account. (orig.).

  3. Proposal for the award of a contract for the construction of an on-site hostel at CERN

    CERN Document Server

    2006-01-01

    This document concerns the award of a contract for the construction of an on-site hostel at CERN. The Finance Committee is invited to agree to the negotiation of a contract with the consortium BATIFLEX (GB) - BATINEG (CH), the lowest bidder, for the construction of an on-site hostel at CERN for a total amount of 5 290 000 Swiss francs, not subject to revision. However, for the reasons explained in this document, the Management wishes to request the Finance Committee to give consideration to the approval of a variant to the original specification to allow use to be made of part of an existing building for the reasons detailed in this document, at an additional cost of 350 000 Swiss francs, not subject to revision, bringing the total construction cost to 5 640 000 Swiss francs.

  4. A comparison of the suitability of different willow varieties to treat on-site wastewater effluent in an Irish climate.

    Science.gov (United States)

    Curneen, S J; Gill, L W

    2014-01-15

    Short rotation coppiced willow trees can be used to treat on-site wastewater effluent with the advantage that, if planted in a sealed basin and sized correctly, they produce no effluent discharge. This paper has investigated the evapotranspiration rate of four different willow varieties while also monitoring the effects of three different effluent types on each variety. The willow varieties used are all cultivars of Salix viminalis. The effluents applied were primary (septic tank) effluent, secondary treated effluent and rain water (control). The results obtained showed that the addition of effluent had a positive effect on the evapotranspiration. The willows were also found to uptake a high proportion of the nitrogen and phosphorus from the primary and secondary treated effluents added during the first year. The effect of the different effluents on the evapotranspiration rate has been used to design ten full scale on-site treatment systems which are now being monitored. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Implementing solutions to barriers to on-site HIV testing in substance abuse treatment: a tale of three facilities.

    Science.gov (United States)

    Hood, Kristina B; Robertson, Angela A; Baird-Thomas, Connie

    2015-04-01

    Due to the scarcity of resources for implementing rapid on-site HIV testing, many substance abuse treatment programs do not offer these services. This study sought to determine whether addressing previously identified implementation barriers to integrating on-site rapid HIV testing into the treatment admissions process would increase offer and acceptance rates. Results indicate that it is feasible to integrate rapid HIV testing into existing treatment programs for substance abusers when resources are provided. Addressing barriers such as providing start-up costs for HIV testing, staff training, addressing staffing needs to reduce competing job responsibilities, and helping treatment staff members overcome their concerns about clients' reactions to positive test results is paramount for the integration and maintenance of such programs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Evaluation of advanced gas chromatographs for on-site analysis. Final CRADA report for number Y-1295-0374

    Energy Technology Data Exchange (ETDEWEB)

    Wise, M.B.; Guerin, M.R.; Palausky, A.; Merriweather, R. [Lockheed Martin Energy Research, Oak Ridge, TN (United States); Forsberg, R.E. [Mine Safety Appliances-Baseline Industries, Lyons, CO (United States)

    1997-02-21

    The EKHO gas chromatography (GC) is being marketed by Mine Safety Appliances as an instrument for on-site environmental analysis and for process applications. This GC utilizes a unique bundled capillary column produced in Russia that provides very fast analysis and a wide linear dynamic range. Oak Ridge National Laboratory (ORNL) has been involved in a CRADA with Mine Safety Appliances in order to evaluate the analytical performance of the EKHO GC and is suitability for on-site environmental applications. Tests that were performed at ORNL included the analysis of air, water, and soil samples for aromatic hydrocarbons including benzene, toluene, xylene, and ethylbenzene (BTEX). These compounds were selected in order to simulate contamination by gasoline and other petroleum fuels. Performance factors that were studied included the instrument detection limits, the linearity, dynamic range, and precision for replicate samples. Other factors that were evaluated include the ease of set-up and operation.

  7. Perceptions of on-site hunters: Environmental concerns, future land use, and cleanup options at the Savannah River Site

    International Nuclear Information System (INIS)

    Burger, J.; Sanchez, J.

    1999-01-01

    The Department of Energy owns land in 34 states, and most of these lands have been off limits to the public for over 50 years. Although some parts of each site are contaminated, most of many sites are not. With the ending of the Cold War, the department is considering alternative land uses. In this article, the perceptions of hunters and fishermen allowed on site for a limited time were examined, about environmental concerns, future land use, and cleanup options. Although loss of jobs was the foremost concern, preserving parts of the site had more support as a future land use than continuing the nuclear mission, and nearly three-quarters of the sample supported cleanup, regardless of cost. On-site employment was a significant indicator of lower concern about safety and environmental issues, less support for designating the site for research, and more concern for maintaining jobs

  8. On-site audits to investigate the quality of radiation physics of radiation therapy institutions in the Republic of Korea.

    Science.gov (United States)

    Park, Jong Min; Park, So-Yeon; Chun, Minsoo; Kim, Sang-Tae

    2017-08-01

    To investigate and improve the domestic standard of radiation therapy in the Republic of Korea. On-site audits were performed for 13 institutions in the Republic of Korea. Six items were investigated by on-site visits of each radiation therapy institution, including collimator, gantry, and couch rotation isocenter check; coincidence between light and radiation fields; photon beam flatness and symmetry; electron beam flatness and symmetry; physical wedge transmission factors; and photon beam and electron beam outputs. The average deviations of mechanical collimator, gantry, and couch rotation isocenter were less than 1mm. Those of radiation isocenter were also less than 1mm. The average difference between light and radiation fields was 0.9±0.6mm for the field size of 20cm×20cm. The average values of flatness and symmetry of the photon beams were 2.9%±0.6% and 1.1%±0.7%, respectively. Those of electron beams were 2.5%±0.7% and 0.6%±1.0%, respectively. Every institutions showed wedge transmission factor deviations less than 2% except one institution. The output deviations of both photon and electron beams were less than ±3% for every institution. Through the on-site audit program, we could effectively detect an inappropriately operating linacs and provide some recommendations. The standard of radiation therapy in Korea is expected to improve through such on-site audits. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. A Study on Site Selecting for National Project including High Level Radioactive Waste Disposal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kilyoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Many national projects are stopped since sites for the projects are not determined. The sites selections are hold by NIMBY for unpleasant facilities or by PYMFY for preferable facilities among local governments. The followings are the typical ones; NIMBY projects: high level radioactive waste disposal, THAAD, Nuclear power plant(NPP), etc. PIMFY projects: South-east new airport, KTX station, Research center for NPP decommission, etc. The site selection for high level radioactive waste disposal is more difficult problem, and thus government did not decide and postpone to a dead end street. Since it seems that there is no solution for site selection for high level radioactive waste disposal due to NIMBY among local governments, a solution method is proposed in this paper. To decide a high level radioactive waste disposal, the first step is to invite a bid by suggesting a package deal including PIMFY projects such as Research Center for NPP decommission. Maybe potential host local governments are asked to submit sealed bids indicating the minimum compensation sum that they would accept the high level radioactive waste disposal site. If there are more than one local government put in a bid, then decide an adequate site by considering both the accumulated PESS point and technical evaluation results. By considering how fairly preferable national projects and unpleasant national projects are distributed among local government, sites selection for NIMBY or PIMFY facilities is suggested. For NIMBY national projects, risk, cost benefit analysis is useful and required since it generates cost value to be used in the PESS. For many cases, the suggested method may be not adequate. However, similar one should be prepared, and be basis to decide sites for NIMBY or PIMFY national projects.

  10. An on-site dosimetry audit for high-energy electron beams

    Directory of Open Access Journals (Sweden)

    Leon de Prez

    2018-01-01

    Full Text Available Background and purpose: External dosimetry audits are powerful quality assurance instruments for radiotherapy. The aim of this study was to implement an electron dosimetry audit based on a contemporary code of practice within the requirements for calibration laboratories performing proficiency tests. This involved the determination of suitable acceptance criteria based on thorough uncertainty analyses. Materials and methods: Subject of the audit was the determination of absorbed dose to water, Dw, and the beam quality specifier, R50,dos. Fifteen electron beams were measured in four institutes according to the Belgian-Dutch code of practice for high-energy electron beams. The expanded uncertainty (k = 2 for the Dw values was 3.6% for a Roos chamber calibrated in 60Co and 3.2% for a Roos chamber cross-calibrated against a Farmer chamber. The expanded uncertainty for the beam quality specifier, R50,dos, was 0.14 cm. The audit acceptance levels were based on the expanded uncertainties for the comparison results and estimated to be 2.4%. Results: The audit was implemented and validated successfully. All Dw audit results were satisfactory with differences in Dw values mostly smaller than 0.5% and always smaller than 1%. Except for one, differences in R50,dos were smaller than 0.2 cm and always smaller than 0.3 cm. Conclusions: An electron dosimetry audit based on absorbed dose to water and present-day requirements for calibration laboratories performing proficiency tests was successfully implemented. It proved international traceability of the participants value with an uncertainty better than 3.6% (k = 2. Keywords: Absorbed dose to water, Audit, Code of practice, Dosimetry, Electron beam, Radiation therapy

  11. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    Science.gov (United States)

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. On-Site Detection of Aflatoxin B1 in Grains by a Palm-Sized Surface Plasmon Resonance Sensor

    Directory of Open Access Journals (Sweden)

    Jeong Moon

    2018-02-01

    Full Text Available Aflatoxins (AFs are highly toxic compounds that can cause both acute and chronic toxicity in humans. Aflatoxin B1 (AFB1 is considered the most toxic of AFs. Therefore, the rapid and on-site detection of AFB1 is critical for food safety management. Here, we report the on-site detection of AFB1 in grains by a portable surface plasmon resonance (SPR sensor. For the detection of AFB1, the surface of an SPR Au chip was sequentially modified by cysteine-protein G, AFB1 antibody, and bovine serum albumin (BSA. Then, the sample solution and AFB1-BSA conjugate were flowed onto the Au chip in serial order. In the absence of AFB1, the SPR response greatly increased due to the binding of AFB1-BSA on the Au chip. In the presence of AFB1, the SPR response showed little change because the small AFB1 molecule binds on the Au chip instead of the large AFB1-BSA molecule. By using this portable SPR-based competitive immunoassay, the sensor showed low limits of detection (2.51 ppb and quantification (16.32 ppb. Furthermore, we successfully detected AFB1 in rice, peanut, and almond samples, which suggests that the proposed sensing method can potentially be applied to the on-site monitoring of mycotoxins in food.

  13. Risks and mitigation options for on-site storage of wastewater from shale gas and tight oil development

    International Nuclear Information System (INIS)

    Kuwayama, Yusuke; Roeshot, Skyler; Krupnick, Alan; Richardson, Nathan; Mares, Jan

    2017-01-01

    We provide a critical review of existing research and information regarding the sources of risk associated with on-site shale gas and tight oil wastewater storage in the United States, the gaps that exist in knowledge regarding these risks, policy and technology options for addressing the risks, and the relative merits of those options. Specifically, we (a) identify the potential risks to human and ecological health associated with on-site storage of shale gas and tight oil wastewater via a literature survey and analysis of data on wastewater spills and regulatory violations, (b) provide a detailed description of government regulations or industry actions that may mitigate these risks to human and ecological health, and (c) provide a critical review of this information to help generate progress toward concrete action to make shale gas and tight oil development more sustainable and more acceptable to a skeptical public, while keeping costs down. - Highlights: • We review current research/information on shale gas and tight oil wastewater storage. • Pit overflows, tank overfills, and liner malfunctions are common spill causes. • Tanks lead to smaller and less frequent spills than pits, but are not a magic bullet. • State regulations for on-site oil and gas wastewater storage are very heterogeneous.

  14. On-Site Molecular Detection of Soil-Borne Phytopathogens Using a Portable Real-Time PCR System.

    Science.gov (United States)

    DeShields, Joseph B; Bomberger, Rachel A; Woodhall, James W; Wheeler, David L; Moroz, Natalia; Johnson, Dennis A; Tanaka, Kiwamu

    2018-02-23

    On-site diagnosis of plant diseases can be a useful tool for growers for timely decisions enabling the earlier implementation of disease management strategies that reduce the impact of the disease. Presently in many diagnostic laboratories, the polymerase chain reaction (PCR), particularly real-time PCR, is considered the most sensitive and accurate method for plant pathogen detection. However, laboratory-based PCRs typically require expensive laboratory equipment and skilled personnel. In this study, soil-borne pathogens of potato are used to demonstrate the potential for on-site molecular detection. This was achieved using a rapid and simple protocol comprising of magnetic bead-based nucleic acid extraction, portable real-time PCR (fluorogenic probe-based assay). The portable real-time PCR approach compared favorably with a laboratory-based system, detecting as few as 100 copies of DNA from Spongospora subterranea. The portable real-time PCR method developed here can serve as an alternative to laboratory-based approaches and a useful on-site tool for pathogen diagnosis.

  15. European Council of Legal Medicine (ECLM) principles for on-site forensic and medico-legal scene and corpse investigation.

    Science.gov (United States)

    Cusack, D; Ferrara, S D; Keller, E; Ludes, B; Mangin, P; Väli, M; Vieira, N

    2017-07-01

    Forensic medical practitioners need to define the general principles governing procedures to be used for the on-site examination of a body where the death has occurred in unnatural, violent or suspicious circumstances. These principles should be followed whenever a medical expert is required to perform an on-site corpse inspection and should be utilised as a set of general guidelines to be adapted to the specific situation in hand and interpreted using common sense and scientific knowledge of the relevant procedures and facts of the case. The aim of these principles is to ensure that forensic evidence at the scene of a death is properly observed and assessed and all necessary relevant evidence gathered in order to ensure that a comprehensive report is available to the judicial authority (investigating judge or coroner) in the justice system. The on-site corpse inspection by a forensic practitioner is a mandatory and essential stage of the forensic and medico-legal autopsy, as it may provide important information for subsequent investigation stages.

  16. The use of modern on-site bioremediation systems to reduce crude oil contamination on oilfield properties

    International Nuclear Information System (INIS)

    Hildebrandt, W.W.; Wilson, S.B.

    1991-01-01

    Oil-field properties frequently have areas in which the soil has been degraded with crude oil. Soil contaminated in this manner is often considered either a hazardous waste or designated waste under regulatory guidelines. As a result, there is often concern about an owner's liabilities and the financial institution's liabilities whenever oilfield properties are transferred to new operators, abandoned, or converted to other uses such as real estate. There is also concern about the methods and relative costs to remediate soil which has been contaminated with crude oil. Modern, well-designed, soil bioremediation systems are cost effective for the treatment of crude oil contamination, and these systems can eliminate an owner's subsequent liabilities. Compared to traditional land-farming practices, a modern on-site bioremediation system (1) requires significantly less surface area, (2) results in lower operating costs, and (3) provides more expeditious results. Compared to excavation and off-site disposal of the contaminated soil, on-site bioremediation will eliminate subsequent liabilities and is typically more cost effective. Case studies indicate that o-site bioremediation systems have been successful at reducing the crude oil contamination in soil to levels which are acceptable to regulatory agencies in less than 10 weeks. Total costs for on-site bioremediation has ranged from $35 to $40 per cubic yard of treated soil, including excavation

  17. Power Talk

    DEFF Research Database (Denmark)

    Liu, Hongpeng; Yang, Yongheng; Loh, Poh Chiang

    2016-01-01

    In this paper, a novel communication strategy called Power Talk is introduced to realize the power line communication among the Voltage Source Converters (VSC) of DC MicroGrids (MGs). Each VSC transmits information by changing the control parameters, and receives information by observing the local...

  18. Power Talk

    DEFF Research Database (Denmark)

    Stefanovic, Cedomir; Popovski, Petar; Angjelichinoski, Marko

    2015-01-01

    We introduce a novel communication strategy for DC Micro Grids (MGs), termed power talk, in which the devices communicate by modulating the power levels in the DC bus. The information is transmitted by varying the parameters that the MG units use to control the level of the common bus voltage...

  19. Nuclear power

    International Nuclear Information System (INIS)

    Abd Khalik Wood

    2003-01-01

    This chapter discuss on nuclear power and its advantages. The concept of nucleus fission, fusion, electric generation are discussed in this chapter. Nuclear power has big potential to become alternative energy to substitute current conventional energy from coal, oil and gas

  20. Power Electronics

    Indian Academy of Sciences (India)

    Such real time models are extremely important, as they can be included in real time simulation of sys- tems to evolve control schemes for the converters as well as to study the effect on the power system. In view of the control possibilities offered by the use of power converters and the newly emerging applications, there has ...