WorldWideScience

Sample records for on-site integrated total

  1. Analysis of a fuel cell on-site integrated energy system for a residential complex

    Science.gov (United States)

    Simons, S. N.; Maag, W. L.

    1979-01-01

    The energy use and costs of the on-site integrated energy system (OS/IES) which provides electric power from an on-site power plant and recovers heat that would normally be rejected to the environment is compared to a conventional system purchasing electricity from a utility and a phosphoric acid fuel cell powered system. The analysis showed that for a 500-unit apartment complex a fuel OS/IES would be about 10% more energy conservative in terms of total coal consumption than a diesel OS/IES system or a conventional system. The fuel cell OS/IES capital costs could be 30 to 55% greater than the diesel OS/IES capital costs for the same life cycle costs. The life cycle cost of a fuel cell OS/IES would be lower than that for a conventional system as long as the cost of electricity is greater than $0.05 to $0.065/kWh. An analysis of several parametric combinations of fuel cell power plant and state-of-art energy recovery systems and annual fuel requirement calculations for four locations were made. It was shown that OS/IES component choices are a major factor in fuel consumption, with the least efficient system using 25% more fuel than the most efficient. Central air conditioning and heat pumps result in minimum fuel consumption while individual air conditioning units increase it, and in general the fuel cell of highest electrical efficiency has the lowest fuel consumption.

  2. Imaging Total Stations - Modular and Integrated Concepts

    Science.gov (United States)

    Hauth, Stefan; Schlüter, Martin

    2010-05-01

    Keywords: 3D-Metrology, Engineering Geodesy, Digital Image Processing Initialized in 2009, the Institute for Spatial Information and Surveying Technology i3mainz, Mainz University of Applied Sciences, forces research towards modular concepts for imaging total stations. On the one hand, this research is driven by the successful setup of high precision imaging motor theodolites in the near past, on the other hand it is pushed by the actual introduction of integrated imaging total stations to the positioning market by the manufacturers Topcon and Trimble. Modular concepts for imaging total stations are manufacturer independent to a large extent and consist of a particular combination of accessory hardware, software and algorithmic procedures. The hardware part consists mainly of an interchangeable eyepiece adapter offering opportunities for digital imaging and motorized focus control. An easy assembly and disassembly in the field is possible allowing the user to switch between the classical and the imaging use of a robotic total station. The software part primarily has to ensure hardware control, but several level of algorithmic support might be added and have to be distinguished. Algorithmic procedures allow to reach several levels of calibration concerning the geometry of the external digital camera and the total station. We deliver insight in our recent developments and quality characteristics. Both the modular and the integrated approach seem to have its individual strengths and weaknesses. Therefore we expect that both approaches might point at different target applications. Our aim is a better understanding of appropriate applications for robotic imaging total stations. First results are presented. Stefan Hauth, Martin Schlüter i3mainz - Institut für Raumbezogene Informations- und Messtechnik FH Mainz University of Applied Sciences Lucy-Hillebrand-Straße 2, 55128 Mainz, Germany

  3. Seismic aftershock monitoring for on-site inspection purposes. Experience from Integrated Field Exercise 2008.

    Science.gov (United States)

    Labak, P.; Arndt, R.; Villagran, M.

    2009-04-01

    One of the sub-goals of the Integrated Field Experiment in 2008 (IFE08) in Kazakhstan was testing the prototype elements of the Seismic aftershock monitoring system (SAMS) for on-site inspection purposes. The task of the SAMS is to collect the facts, which should help to clarify nature of the triggering event. Therefore the SAMS has to be capable to detect and identify events as small as magnitude -2 in the inspection area size up to 1000 km2. Equipment for 30 mini-arrays and 10 3-component stations represented the field equipment of the SAMS. Each mini-array consisted of a central 3-component seismometer and 3 vertical seismometers at the distance about 100 m from the central seismometer. The mini-arrays covered approximately 80% of surrogate inspection area (IA) on the territory of former Semipalatinsk test site. Most of the stations were installed during the first four days of field operations by the seismic sub-team, which consisted of 10 seismologists. SAMS data center comprised 2 IBM Blade centers and 8 working places for data archiving, detection list production and event analysis. A prototype of SAMS software was tested. Average daily amount of collected raw data was 15-30 GB and increased according to the amount of stations entering operation. Routine manual data screening and data analyses were performed by 2-6 subteam members. Automatic screening was used for selected time intervals. Screening was performed using the Sonoview program in frequency domain and using the Geotool and Hypolines programs for screening in time domain. The screening results were merged into the master event list. The master event list served as a basis of detailed analysis of unclear events and events identified to be potentially in the IA. Detailed analysis of events to be potentially in the IA was performed by the Hypoline and Geotool programs. In addition, the Hyposimplex and Hypocenter programs were also used for localization of events. The results of analysis were integrated

  4. Total Site Heat Integration Considering Pressure Drops

    Directory of Open Access Journals (Sweden)

    Kew Hong Chew

    2015-02-01

    Full Text Available Pressure drop is an important consideration in Total Site Heat Integration (TSHI. This is due to the typically large distances between the different plants and the flow across plant elevations and equipment, including heat exchangers. Failure to consider pressure drop during utility targeting and heat exchanger network (HEN synthesis may, at best, lead to optimistic energy targets, and at worst, an inoperable system if the pumps or compressors cannot overcome the actual pressure drop. Most studies have addressed the pressure drop factor in terms of pumping cost, forbidden matches or allowable pressure drop constraints in the optimisation of HEN. This study looks at the implication of pressure drop in the context of a Total Site. The graphical Pinch-based TSHI methodology is extended to consider the pressure drop factor during the minimum energy requirement (MER targeting stage. The improved methodology provides a more realistic estimation of the MER targets and valuable insights for the implementation of the TSHI design. In the case study, when pressure drop in the steam distribution networks is considered, the heating and cooling duties increase by 14.5% and 4.5%.

  5. TOWARDS TOTAL INTEGRATION IN DESIGN STUDIO

    Directory of Open Access Journals (Sweden)

    Shireesh A Deshpande

    2010-07-01

    Full Text Available Transmission of knowledge has been defined as “bringing the right knowledge by the right route at the right time to the right places.” In this context there is need to analyze the various pedagogical shifts associated with the decisive process of transmission and transaction of knowledge in design studio. Critical understanding of the importance of tangential knowledge and its integration within the design studio, leading to a comprehensive whole, is a significant aspect to be properly evolved and nourished in the studio. It can be argued that knowledge is not a substitute for architectural imagination but inadequate knowledge would handicap the general level of design. Being satisfied to manipulate formal configurations does not provide insights into the human experience. If the different types of knowledge that architecture requires are ignored, the profession will lose its credibility in the eyes of society. With the body of knowledge expanding diversely with the escalating wants of the user, and to further sustain the built environment with further progression, it’s quite certain to have an innovative design process that has a feel of antecedents yet is nourished by rationalism. Architectural Design is to an extent the yield of a creative process brought out through a refined approach, skill, and dexterity to suit the purpose. The assessors, the jury, or the teacher has created an aura of mystique around good design, without much explaining what good design is. Architectural education involves application of a theory of knowledge – what is known and how it is to be known. Nothing is taught unless it is learnt (Bono. Does the key to these issues lie in shifting from conventional mode to Total Integration Mode of Education?

  6. Total Ore Processing Integration and Management

    Energy Technology Data Exchange (ETDEWEB)

    Leslie Gertsch

    2006-05-15

    This report outlines the technical progress achieved for project DE-FC26-03NT41785 (Total Ore Processing Integration and Management) during the period 01 January through 31 March of 2006. (1) Work in Progress: Minntac Mine--Graphical analysis of drill monitor data moved from two-dimensional horizontal patterns to vertical variations in measured and calculated parameters. The rock quality index and the two dimensionless ({pi}) indices developed by Kewen Yin of the University of Minnesota are used by Minntac Mine to design their blasts, but the drill monitor data from any given pattern is obviously not available for the design of that shot. Therefore, the blast results--which are difficult to quantify in a short time--must be back-analyzed for comparison with the drill monitor data to be useful for subsequent blast designs. {pi}{sub 1} indicates the performance of the drill, while {pi}{sub 2} is a measure of the rock resistance to drilling. As would be expected, since a drill tends to perform better in rock that offers little resistance, {pi}{sub 1} and {pi}{sub 2} are strongly inversely correlated; the relationship is a power function rather than simply linear. Low values of each Pi index tend to be quantized, indicating that these two parameters may be most useful above certain minimum magnitudes. (2) Work in Progress: Hibtac Mine--Statistical examination of a data set from Hibtac Mine (Table 1) shows that incorporating information on the size distribution of material feeding from the crusher to the autogenous mills improves the predictive capability of the model somewhat (43% vs. 44% correlation coefficient), but a more important component is production data from preceding days (26% vs. 44% correlation coefficient), determined using exponentially weighted moving average predictive variables. This lag effect likely reflects the long and varied residence times of the different size fragments in the grinding mills. The rock sizes are also correlated with the geologic

  7. Implementation of an Integrated, Portable Transformer Condition Monitoring Instrument in the Classroom and On-Site

    Science.gov (United States)

    Chatterjee, B.; Dey, D.; Chakravorti, S.

    2010-01-01

    The development of integrated, portable, transformer condition monitoring (TCM) equipment for classroom demonstrations as well as for student exercises conducted in the field is discussed. Demonstrations include experimentation with real-world transformers to illustrate concepts such as polarization and depolarization current through oil-paper…

  8. Total Site Integration and paper machine technologies; Total site integration ja paperikoneteknologia - PMST 02

    Energy Technology Data Exchange (ETDEWEB)

    Puumalainen, T; Kaijaluoto, S; Tervonen, P; Edelmann, K [VTT Energy, Jyvaeskylae (Finland)

    1999-12-31

    During the last 30 years the production capacity of a paper machine has tripled. The fastest machines of today run over about 1600 m/min, the web width being around 10 m. The desire to further increase the production capacity is leading to more expensive paper machines and to larger buildings, if current pressing and drying techniques are used. New pressing and drying techniques will decrease the need of thermal energy. Closed water cycles reduce the need of secondary heat abundantly available from the dryer section based on cylinder drying. Total Site Integration studies are required when the effect of new process concepts are to be evaluated against energy efficiency and environmental impacts. A proto type tool has been developed and the effect of new paper machine concepts on energy consumption have been analysed. The utilisation possibilities of the surplus energy will be studied later in the course of this project. (orig.)

  9. Total Site Integration and paper machine technologies; Total site integration ja paperikoneteknologia - PMST 02

    Energy Technology Data Exchange (ETDEWEB)

    Puumalainen, T.; Kaijaluoto, S.; Tervonen, P.; Edelmann, K. [VTT Energy, Jyvaeskylae (Finland)

    1998-12-31

    During the last 30 years the production capacity of a paper machine has tripled. The fastest machines of today run over about 1600 m/min, the web width being around 10 m. The desire to further increase the production capacity is leading to more expensive paper machines and to larger buildings, if current pressing and drying techniques are used. New pressing and drying techniques will decrease the need of thermal energy. Closed water cycles reduce the need of secondary heat abundantly available from the dryer section based on cylinder drying. Total Site Integration studies are required when the effect of new process concepts are to be evaluated against energy efficiency and environmental impacts. A proto type tool has been developed and the effect of new paper machine concepts on energy consumption have been analysed. The utilisation possibilities of the surplus energy will be studied later in the course of this project. (orig.)

  10. One Team, One Fight, One Future, Total Army Integration

    National Research Council Canada - National Science Library

    1998-01-01

    ...; and, most important, our vision for maintaining a trained and ready force. As the ideas in One Team, One Fight, One Future unfold, you will find the key themes of Total Army integration emerging again and again...

  11. Integrated Communications at America's Leading Total Quality Management Corporations.

    Science.gov (United States)

    Gronstedt, Anders

    1996-01-01

    Examines how to create organizational processes that allow communication professionals with a variety of expertise to support each other through coordination and integration. Studies eight of America's leading total quality management corporations, including AT&T, Federal Express, Saturn, and Xerox. Explores how various total quality…

  12. Integrating total quality management in a library setting

    CERN Document Server

    Jurow, Susan

    2013-01-01

    Improve the delivery of library services by implementing total quality management (TQM), a system of continuous improvement employing participative management and centered on the needs of customers. Although TQM was originally designed for and successfully applied in business and manufacturing settings, this groundbreaking volume introduces strategies for translating TQM principles from the profit-based manufacturing sector to the library setting. Integrating Total Quality Management in a Library Setting shows librarians how to improve library services by implementing strategies such as employ

  13. Relative Hom-Hopf modules and total integrals

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Shuangjian [School of Mathematics and Statistics, Guizhou University of Finance and Economics, Guiyang 550025 (China); Zhang, Xiaohui [Department of Mathematics, Southeast University, Nanjing 210096 (China); Wang, Shengxiang, E-mail: wangsx-math@163.com [School of Mathematics and Finance, Chuzhou University, Chuzhou 239000 (China); Department of Mathematics, Nanjing University, Nanjing 210093 (China)

    2015-02-15

    Let (H, α) be a monoidal Hom-Hopf algebra and (A, β) a right (H, α)-Hom-comodule algebra. We first investigate the criterion for the existence of a total integral of (A, β) in the setting of monoidal Hom-Hopf algebras. Also, we prove that there exists a total integral ϕ : (H, α) → (A, β) if and only if any representation of the pair (H, A) is injective in a functorial way, as a corepresentation of (H, α), which generalizes Doi’s result. Finally, we define a total quantum integral γ : H → Hom(H, A) and prove the following affineness criterion: if there exists a total quantum integral γ and the canonical map ψ : A⊗{sub B}A → A ⊗ H, a⊗{sub B}b ↦ β{sup −1}(a) b{sub [0]} ⊗ α(b{sub [1]}) is surjective, then the induction functor A⊗{sub B}−:ℋ{sup ~}(ℳ{sub k}){sub B}→ℋ{sup ~}(ℳ{sub k}){sub A}{sup H} is an equivalence of categories.

  14. Relative Hom-Hopf modules and total integrals

    International Nuclear Information System (INIS)

    Guo, Shuangjian; Zhang, Xiaohui; Wang, Shengxiang

    2015-01-01

    Let (H, α) be a monoidal Hom-Hopf algebra and (A, β) a right (H, α)-Hom-comodule algebra. We first investigate the criterion for the existence of a total integral of (A, β) in the setting of monoidal Hom-Hopf algebras. Also, we prove that there exists a total integral ϕ : (H, α) → (A, β) if and only if any representation of the pair (H, A) is injective in a functorial way, as a corepresentation of (H, α), which generalizes Doi’s result. Finally, we define a total quantum integral γ : H → Hom(H, A) and prove the following affineness criterion: if there exists a total quantum integral γ and the canonical map ψ : A⊗ B A → A ⊗ H, a⊗ B b ↦ β −1 (a) b [0] ⊗ α(b [1] ) is surjective, then the induction functor A⊗ B −:ℋ ~ (ℳ k ) B →ℋ ~ (ℳ k ) A H is an equivalence of categories

  15. Total Correlation Function Integrals and Isothermal Compressibilities from Molecular Simulations

    DEFF Research Database (Denmark)

    Wedberg, Rasmus; Peters, Günther H.j.; Abildskov, Jens

    2008-01-01

    Generation of thermodynamic data, here compressed liquid density and isothermal compressibility data, using molecular dynamics simulations is investigated. Five normal alkane systems are simulated at three different state points. We compare two main approaches to isothermal compressibilities: (1...... in approximately the same amount of time. This suggests that computation of total correlation function integrals is a route to isothermal compressibility, as accurate and fast as well-established benchmark techniques. A crucial step is the integration of the radial distribution function. To obtain sensible results...

  16. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    Science.gov (United States)

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  17. Total Dose Effects on Bipolar Integrated Circuits at Low Temperature

    Science.gov (United States)

    Johnston, A. H.; Swimm, R. T.; Thorbourn, D. O.

    2012-01-01

    Total dose damage in bipolar integrated circuits is investigated at low temperature, along with the temperature dependence of the electrical parameters of internal transistors. Bandgap narrowing causes the gain of npn transistors to decrease far more at low temperature compared to pnp transistors, due to the large difference in emitter doping concentration. When irradiations are done at temperatures of -140 deg C, no damage occurs until devices are warmed to temperatures above -50 deg C. After warm-up, subsequent cooling shows that damage is then present at low temperature. This can be explained by the very strong temperature dependence of dispersive transport in the continuous-time-random-walk model for hole transport. For linear integrated circuits, low temperature operation is affected by the strong temperature dependence of npn transistors along with the higher sensitivity of lateral and substrate pnp transistors to radiation damage.

  18. Development of a totally integrated severe accident training system

    International Nuclear Information System (INIS)

    Kim, Ko Ryu; Park, Sun Hee; Choi, Young; Kim, Dong Ha

    2006-01-01

    Recently KAERI has developed the severe accident management guidance to establish the Korea standard severe accident management system. On the other hand the PC-based severe accident training simulator SATS has been developed, which uses the MELCOR code as the simulation engine. The simulator SATS graphically displays and simulates the severe accidents with interactive user commands. Especially the control capability of SATS could make a severe accident training course more interesting and effective. In this paper we will describe the development and functions of the electrical guidance module, HyperKAMG, and the SATS-HyperKAMG linkage system designed for a totally integrated and automated severe accident training. (author)

  19. Total quality through computer integrated manufacturing in the pharmaceutical industry.

    Science.gov (United States)

    Ufret, C M

    1995-01-01

    The role of Computer Integrated Manufacturing (CIM) in the pursue of total quality in pharmaceutical manufacturing is assessed. CIM key objectives, design criteria, and performance measurements, in addition to its scope and implementation in a hierarchical structure, are explored in detail. Key elements for the success of each phase in a CIM project and a brief status of current CIM implementations in the pharmaceutical industry are presented. The role of World Class Manufacturing performance standards and other key issues to achieve full CIM benefits are also addressed.

  20. Integral bounds for N-body total cross sections

    International Nuclear Information System (INIS)

    Osborn, T.A.; Bolle, D.

    1979-01-01

    We study the behavior of the total cross sections in the three- and N-body scattering problem. Working within the framework of the time-dependent two-Hilbert space scattering theory, we give a simple derivation of integral bounds for the total cross section for all processes initiated by the collision of two clusters. By combining the optical theorem with a trace identity derived by Jauch, Sinha, and Misra, we find, roughly speaking, that if the local pairwise interaction falls off faster than r -3 , then sigma/sub tot/(E) must decrease faster than E/sup -1/2/ at high energy. This conclusion is unchanged if one introduces a class of well-behaved three-body interactions

  1. Industrial implementation issues of Total Site Heat Integration

    International Nuclear Information System (INIS)

    Chew, Kew Hong; Klemeš, Jiří Jaromír; Wan Alwi, Sharifah Rafidah; Abdul Manan, Zainuddin

    2013-01-01

    Heat Integration has been a well-established energy conservation strategy in the industry. Total Site Heat Integration (TSHI) has received growing interest since its inception in the 90s. The methodology has been used with certain simplifications to solve TSHI problems. This paper investigates the main issues that can influence the practical implementation of TSHI in the industry. The main aim is to provide an assessment and possible guidance for future development and extension of the TSHI methodology from the industrial perspective. Several key issues have been identified as being of vital importance for the industries: design, operation, reliability/availability/maintenance, regulatory/policy and economics. Design issues to consider include plant layout, pressure drop, etc. For operation, issues such as startup and shutdown need to be considered. Reliability, availability and maintenance (RAM) are important as they directly affect the production. Relevant government policy and incentives are also important when considering the options for TSHI. Finally, a TSHI system needs to be economically viable. This paper highlights the key issues to be considered for a successful implementation of TSHI. The impacts of these issues on TS integration are summarised in a matrix, which forms a basis for an improved and closer-to-real-life implementation of the TSHI methodology. Highlights: ► Current TSHI methodology has been used for solving models with certain simplifications. ► Several issues that can influence practical implementation of TSHI are identified. ► Impacts of these issues on safety, environment and economics are evaluated. ► The findings form a basis for an improved and practical implementation of TSHI

  2. Methods of assessing total doses integrated across pathways

    International Nuclear Information System (INIS)

    Grzechnik, M.; Camplin, W.; Clyne, F.; Allott, R.; Webbe-Wood, D.

    2006-01-01

    Calculated doses for comparison with limits resulting from discharges into the environment should be summed across all relevant pathways and food groups to ensure adequate protection. Current methodology for assessments used in the radioactivity in Food and the Environment (R.I.F.E.) reports separate doses from pathways related to liquid discharges of radioactivity to the environment from those due to gaseous releases. Surveys of local inhabitant food consumption and occupancy rates are conducted in the vicinity of nuclear sites. Information has been recorded in an integrated way, such that the data for each individual is recorded for all pathways of interest. These can include consumption of foods, such as fish, crustaceans, molluscs, fruit and vegetables, milk and meats. Occupancy times over beach sediments and time spent in close proximity to the site is also recorded for inclusion of external and inhalation radiation dose pathways. The integrated habits survey data may be combined with monitored environmental radionuclide concentrations to calculate total dose. The criteria for successful adoption of a method for this calculation were: Reproducibility can others easily use the approach and reassess doses? Rigour and realism how good is the match with reality?Transparency a measure of the ease with which others can understand how the calculations are performed and what they mean. Homogeneity is the group receiving the dose relatively homogeneous with respect to age, diet and those aspects that affect the dose received? Five methods of total dose calculation were compared and ranked according to their suitability. Each method was labelled (A to E) and given a short, relevant name for identification. The methods are described below; A) Individual doses to individuals are calculated and critical group selection is dependent on dose received. B) Individual Plus As in A, but consumption and occupancy rates for high dose is used to derive rates for application in

  3. Effects of total dose of ionizing radiation on integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marcilei A.G.; Cirne, K.H.; Gimenez, S.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Added, N.; Barbosa, M.D.L.; Medina, N.H.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de; Seixas Junior, L.E.; Melo, W. [Centro de Tecnologia da Informacao Paulo Archer, Sao Paulo, SP (Brazil)

    2011-07-01

    Full text: The study of ionizing radiation effects on materials used in electronic devices is of great relevance for the progress of global technological development and, particularly, it is a necessity in some strategic areas in Brazil. Electronic circuits are strongly influenced by radiation and the need for IC's featuring radiation hardness is largely growing to meet the stringent environment in space electronics. On the other hand, aerospace agencies are encouraging both scientific community and semiconductors industry to develop hardened-by-design components using standard manufacturing processes to achieve maximum performance, while significantly reducing costs. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them alpha particles, protons, gamma and X-rays. Radiation effects on the integrated circuits are usually divided into two categories: total ionizing dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; single events effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits. TID is one of the most common effects and may generate degradation in some parameters of the CMOS electronic devices, such as the threshold voltage oscillation, increase of the sub-threshold slope and increase of the off-state current. The effects of ionizing radiation are the creation of electron-hole pairs in the oxide layer changing operation mode parameters of the electronic device. Indirectly, there will be also changes in the device due to the formation of secondary electrons from the interaction of electromagnetic radiation with the material, since the charge carriers can be trapped both in the oxide layer and in the interface with the oxide. In this work we have investigated the behavior of MOSFET devices fabricated with

  4. A system and approach for total pipeline integrity management

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Todd; Neidhardt, Dietmar [Tuboscope Pipeline Services, Houston, TX (United States); Gonzalez, Oscar [Tuboscope Mexico S.A. de C.V., Mexico, D.F. (Mexico)

    2005-07-01

    Pipeline rehabilitation and maintenance decisions are made using a wide variety of data, criteria, and expertise. The goal is to arrive at an optimal plan that considers risk and best return on Repair and Maintenance (R and M) expenditures for aging pipeline systems in both regulated and non-regulated environments. In order to achieve these goals, historical, operations, and assessment data is gathered, aligned and integrated as part of a baseline assessment. Integrity threats are identified based on operations and industry experience, and combined with potential consequences to public safety, the environment, and business to clearly delineate high risk exposure segments in the system. Integrity assessments are conducted in a prioritized manner, using the most appropriate technology and methods to address the threats. These include In Line Inspection technologies: MFL, Deformation, UT, INS (combinations thereof), Direct Assessment for EC and SCC threats, Hydro testing, and other indirect methods. From these results, decisions are made and R and M plans developed. To arrive at an optimal R and M plan, proper use of existing data, new integrity assessment data, and decision risk models is required. This paper presentation will detail the tactical aspect of an effective integrity management platform. Experience in decision support, operations priorities and execution of a rehabilitation plan using LinaView Pro{sup TM} integrity management system with risk-based integrity tools and maintenance planning will be presented. A process overview, results, and benefits will be given using these examples from operating oil and gas transmission pipelines. (author)

  5. Integration of virtual control units in the total vehicle simulation; Integration virtueller Steuergeraete in die Gesamtfahrzeugsimulation

    Energy Technology Data Exchange (ETDEWEB)

    Soppa, Andreas; Lund, Christoph [Volkswagen AG, Wolfsburg (Germany)

    2012-11-01

    In this article the simulation of information and energetics of vehicles with model-integration of electronic control units (ECU) in a simulation, based on the coupling of physical and control components of the total vehicle are investigated. For that simplified models of ECU's, simulating the functionally of the real ECU's, were used. The integration of virtual EUC's in models of full vehicles makes it possible to simulate the energetics for different driving cycles in a realistic way. By better simulation results an evaluation of physical components and the amount of functions are possible. In the area of the thermal management of vehicles by this analyses and optimizations of functions become possible. This article shows the advantages of embedding virtual ECU's in simulations of full vehicles. (orig.)

  6. Total site integration of light hydrocarbons separation process

    OpenAIRE

    Ulyev, L.; Vasilyev, M.; Maatouk, A.; Duic, Neven; Khusanovc, Alisher

    2016-01-01

    Ukraine is the largest consumer of hydrocarbons per unit of production in Europe (Ukraine policy review, 2006). The most important point is a reduction of energy consumption in chemical and metallurgical industries as a biggest consumer. This paper deals with energy savings potential of light hydrocarbons separation process. Energy consumption of light hydrocarbons separation process processes typical of Eastern European countries were analysed. Process Integration (PI) was used to perform a ...

  7. Micro Total Analysis Systems: Microfluidic aspects, integration concept and applications

    NARCIS (Netherlands)

    van den Berg, Albert; Lammerink, Theodorus S.J.

    1997-01-01

    In this contribution three aspects of miniaturized total analysis systems (µTAS) are described and discussed in detail. First, an overview of microfabricated components for fluid handling is given. A description of the importance of sampling- and fluid-handling techniques is followed by details of

  8. Employee satisfaction: an integral component of total quality.

    Science.gov (United States)

    Gvazdinskas, L C; Maffetone, M A

    1995-01-01

    As part of the Total Quality Management process, the leadership of Rush Medical Laboratories, with a staff of 400, made an initial commitment to focus on their own employees as the most important customers. Only after the employees' development, their help, their support, and their empowerment could Rush Medical Laboratories make the improvements in customer relationships and obtain the operations improvement, cost savings, and productivity necessary to maintain a competitive edge. This article outlines the numerous employee initiatives that have resulted from this commitment. All of these initiatives were successful at some point during the 5 or more years since the incorporation of TQM within Rush Medical Laboratories. In the spirit of continuous improvement, some have been modified or discontinued and replaced by others. This article provides an overview of the many improvements that are possible when employees are provided a forum in which to voice their needs, and it challenges the management and employees of all laboratories to focus on this vital component of total quality.

  9. Integrating Total Quality Management (TQM) and hazardous waste management

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, Nancy [Colorado State Univ., Fort Collins, CO (United States)

    1993-11-01

    The Resource Conservation and Recovery Act (RCRA) of 1976 and its subsequent amendments have had a dramatic impact on hazardous waste management for business and industry. The complexity of this law and the penalties for noncompliance have made it one of the most challenging regulatory programs undertaken by the Environmental Protection Agency (EPA). The fundamentals of RCRA include ``cradle to grave`` management of hazardous waste, covering generators, transporters, and treatment, storage, and disposal facilities. The regulations also address extensive definitions and listing/identification mechanisms for hazardous waste along with a tracking system. Treatment is favored over disposal and emphasis is on ``front-end`` treatment such as waste minimization and pollution prevention. A study of large corporations such as Xerox, 3M, and Dow Chemical, as well as the public sector, has shown that well known and successful hazardous waste management programs emphasize pollution prevention and employment of techniques such as proactive environmental management, environmentally conscious manufacturing, and source reduction. Nearly all successful hazardous waste programs include some aspects of Total Quality Management, which begins with a strong commitment from top management. Hazardous waste management at the Rocky Flats Plant is further complicated by the dominance of ``mixed waste`` at the facility. The mixed waste stems from the original mission of the facility, which was production of nuclear weapons components for the Department of Energy (DOE). A Quality Assurance Program based on the criterion in DOE Order 5700.6C has been implemented at Rocky Flats. All of the elements of the Quality Assurance Program play a role in hazardous waste management. Perhaps one of the biggest waste management problems facing the Rocky Flats Plant is cleaning up contamination from a forty year mission which focused on production of nuclear weapon components.

  10. Integrating Total Quality Management (TQM) and hazardous waste management

    International Nuclear Information System (INIS)

    Kirk, N.

    1993-01-01

    The Resource Conservation and Recovery Act (RCRA) of 1976 and its subsequent amendments have had a dramatic impact on hazardous waste management for business and industry. The complexity of this law and the penalties for noncompliance have made it one of the most challenging regulatory programs undertaken by the Environmental Protection Agency (EPA). The fundamentals of RCRA include ''cradle to grave'' management of hazardous waste, covering generators, transporters, and treatment, storage, and disposal facilities. The regulations also address extensive definitions and listing/identification mechanisms for hazardous waste along with a tracking system. Treatment is favored over disposal and emphasis is on ''front-end'' treatment such as waste minimization and pollution prevention. A study of large corporations such as Xerox, 3M, and Dow Chemical, as well as the public sector, has shown that well known and successful hazardous waste management programs emphasize pollution prevention and employment of techniques such as proactive environmental management, environmentally conscious manufacturing, and source reduction. Nearly all successful hazardous waste programs include some aspects of Total Quality Management, which begins with a strong commitment from top management. Hazardous waste management at the Rocky Flats Plant is further complicated by the dominance of ''mixed waste'' at the facility. The mixed waste stems from the original mission of the facility, which was production of nuclear weapons components for the Department of Energy (DOE). A Quality Assurance Program based on the criterion in DOE Order 5700.6C has been implemented at Rocky Flats. All of the elements of the Quality Assurance Program play a role in hazardous waste management. Perhaps one of the biggest waste management problems facing the Rocky Flats Plant is cleaning up contamination from a forty year mission which focused on production of nuclear weapon components

  11. A Notion of Total Dual Integrality for Convex, Semidefinite, and Extended Formulations

    OpenAIRE

    Silva, Marcel K. de Carli; Tunçel, Levent

    2018-01-01

    Total dual integrality is a powerful and unifying concept in polyhedral combinatorics and integer programming that enables the refinement of geometric min-max relations given by linear programming Strong Duality into combinatorial min-max theorems. The definition of total dual integrality (TDI) revolves around the existence of optimal dual solutions that are integral, and thus naturally applies to a host of combinatorial optimization problems that are cast as integer programs whose LP relaxat...

  12. A multilayered integrated sensor for three-dimensional, micro total analysis systems

    International Nuclear Information System (INIS)

    Xiao, Jing; Song, Fuchuan; Seo, Sang-Woo

    2013-01-01

    This paper presents a layer-by-layer integration approach of different functional devices and demonstrates a heterogeneously integrated optical sensor featuring a micro-ring resonator and a high-speed thin-film InGaAs-based photodetector co-integrated with a microfluidic droplet generation device. A thin optical device structure allows a seamless integration with other polymer-based devices on a silicon platform. The integrated sensor successfully demonstrates its transient measurement capability of two-phase liquid flow in a microfluidic droplet generation device. The proposed approach represents an important step toward fully integrated micro total analysis systems. (paper)

  13. Optimal solution of full fuzzy transportation problems using total integral ranking

    Science.gov (United States)

    Sam’an, M.; Farikhin; Hariyanto, S.; Surarso, B.

    2018-03-01

    Full fuzzy transportation problem (FFTP) is a transportation problem where transport costs, demand, supply and decision variables are expressed in form of fuzzy numbers. To solve fuzzy transportation problem, fuzzy number parameter must be converted to a crisp number called defuzzyfication method. In this new total integral ranking method with fuzzy numbers from conversion of trapezoidal fuzzy numbers to hexagonal fuzzy numbers obtained result of consistency defuzzyfication on symmetrical fuzzy hexagonal and non symmetrical type 2 numbers with fuzzy triangular numbers. To calculate of optimum solution FTP used fuzzy transportation algorithm with least cost method. From this optimum solution, it is found that use of fuzzy number form total integral ranking with index of optimism gives different optimum value. In addition, total integral ranking value using hexagonal fuzzy numbers has an optimal value better than the total integral ranking value using trapezoidal fuzzy numbers.

  14. Three-tiered integration of PACS and HIS toward next generation total hospital information system.

    Science.gov (United States)

    Kim, J H; Lee, D H; Choi, J W; Cho, H I; Kang, H S; Yeon, K M; Han, M C

    1998-01-01

    The Seoul National University Hospital (SNUH) started a project to innovate the hospital information facilities. This project includes installation of high speed hospital network, development of new HIS, OCS (order communication system), RIS and PACS. This project aims at the implementation of the first total hospital information system by seamlessly integrating these systems together. To achieve this goal, we took three-tiered systems integration approach: network level, database level, and workstation level integration. There are 3 loops of networks in SNUH: proprietary star network for host computer based HIS, Ethernet based hospital LAN for OCS and RIS, and ATM based network for PACS. They are linked together at the backbone level to allow high speed communication between these systems. We have developed special communication modules for each system that allow data interchange between different databases and computer platforms. We have also developed an integrated workstation in which both the OCS and PACS application programs run on a single computer in an integrated manner allowing the clinical users to access and display radiological images as well as textual clinical information within a single user environment. A study is in progress toward a total hospital information system in SNUH by seamlessly integrating the main hospital information resources such as HIS, OCS, and PACS. With the three-tiered systems integration approach, we could successfully integrate the systems from the network level to the user application level.

  15. An Integrated Multimodal Sensor for the On-site Monitoring of the Water Content and Nutrient Concentration of Soil by Measuring the Phase and Electrical Conductivity

    Directory of Open Access Journals (Sweden)

    Masato FUTAGAWA

    2012-03-01

    Full Text Available We have fabricated a new multimodal sensor chip which is capable of simultaneous on-site measurements of the water content and nutrient concentration. Until now, in agriculture, water content sensors, such as TDR sensors, have been unable to provide accurate measurements, since these sensors are affected by the nutrient concentration in the soil solution. Therefore, tensiometers have generally been used. However, these are large-scale sensors and are not suitable for the precise measurements required in agriculture. Our proposed sensors are the world’s first to enable independent measurements of the water content and nutrient concentration.

  16. Total Quality Management and Organizational Behavior Management: An Integration for Continual Improvement.

    Science.gov (United States)

    Mawhinney, Thomas C.

    1992-01-01

    The history and main features of organizational behavior management (OBM) are compared and integrated with those of total quality management (TQM), with emphasis on W.E. Deming's 14 points and OBM's operant-based approach to performance management. Interventions combining OBM, TQM, and statistical process control are recommended. (DB)

  17. Integration of electrochemistry in micro-total analysis systems for biochemical assays: recent developments.

    Science.gov (United States)

    Xu, Xiaoli; Zhang, Song; Chen, Hui; Kong, Jilie

    2009-11-15

    Micro-total analysis systems (microTAS) integrate different analytical operations like sample preparation, separation and detection into a single microfabricated device. With the outstanding advantages of low cost, satisfactory analytical efficiency and flexibility in design, highly integrated and miniaturized devices from the concept of microTAS have gained widespread applications, especially in biochemical assays. Electrochemistry is shown to be quite compatible with microanalytical systems for biochemical assays, because of its attractive merits such as simplicity, rapidity, high sensitivity, reduced power consumption, and sample/reagent economy. This review presents recent developments in the integration of electrochemistry in microdevices for biochemical assays. Ingenious microelectrode design and fabrication methods, and versatility of electrochemical techniques are involved. Practical applications of such integrated microsystem in biochemical assays are focused on in situ analysis, point-of-care testing and portable devices. Electrochemical techniques are apparently suited to microsystems, since easy microfabrication of electrochemical elements and a high degree of integration with multi-analytical functions can be achieved at low cost. Such integrated microsystems will play an increasingly important role for analysis of small volume biochemical samples. Work is in progress toward new microdevice design and applications.

  18. Total and Direct Correlation Function Integrals from Molecular Simulation of Binary Systems

    DEFF Research Database (Denmark)

    Wedberg, Nils Hejle Rasmus Ingemar; O’Connell, John P.; Peters, Günther H.J.

    2011-01-01

    The possibility for obtaining derivative properties for mixtures from integrals of spatial total and direct correlation functions obtained from molecular dynamics simulations is explored. Theoretically well-supported methods are examined to extend simulation radial distribution functions to long...... are consistent with an excess Helmholtz energy model fitted to available simulations. In addition, simulations of water/methanol and water/t-butanol mixtures have been carried out. The method yields results for partial molar volumes, activity coefficient derivatives, and individual correlation function integrals...... in reasonable agreement with smoothed experimental data. The proposed method for obtaining correlation function integrals is shown to perform at least as well as or better than two previously published approaches....

  19. QUALITY MANAGEMENT AND INTEGRATED TOTAL QUALITY IN SPANISH MINING: RESULTS OF AN EMPIRICAL STUDY

    OpenAIRE

    ESCANCIANO, CARMEN; IGLESIAS-RODRÍGUEZ, FRANCISCO-JAVIER

    2012-01-01

    This paper presents the results of an empirical study conducted in Spain among mining companies that hold ISO 9001 certification. This study aimed at reflecting upon quality management in Spanish mining; and discovering whether the certification of a quality management system provides companies with a framework for integrating total quality management with other management systems, such as environmental management or occupational health and safety management. En este artículo se presentan ...

  20. Test methods of total dose effects in very large scale integrated circuits

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; He Baoping; Yao Yujuan; Li Yonghong; Peng Honglun; Lin Dongsheng; Zhou Hui; Chen Yusheng

    2004-01-01

    A kind of test method of total dose effects (TDE) is presented for very large scale integrated circuits (VLSI). The consumption current of devices is measured while function parameters of devices (or circuits) are measured. Then the relation between data errors and consumption current can be analyzed and mechanism of TDE in VLSI can be proposed. Experimental results of 60 Co γ TDEs are given for SRAMs, EEPROMs, FLASH ROMs and a kind of CPU

  1. Present on Site

    DEFF Research Database (Denmark)

    Ingemann, Bruno

    Why are exhibitions and museums so important? What can they be used for? Who determines relevance in a transformative process? Transforming exhibitions is not just something you do, it is something that gets better the more you do it. This book looks at the intersection of the visitor or user, who...... gets personal and cultural meaning from their visit and the museum as it appears in the design of the exhibition. It examines on-site communication for intentional and hidden content and messages, and reveals possible relations to the visitor, his or her world and society in general. This investigation...... also focuses on the processes involved in interpretation and design and takes a closer look at the practices of exhibiting rather than the objects on display. The four main themes in the book are: • Constructions – The visitor at an exhibition • Questions – Experience and learning processes...

  2. A smartphone colorimetric reader integrated with an ambient light sensor and a 3D printed attachment for on-site detection of zearalenone.

    Science.gov (United States)

    Chen, Yuan; Fu, Qiangqiang; Li, Dagang; Xie, Jun; Ke, Dongxu; Song, Qifang; Tang, Yong; Wang, Hong

    2017-11-01

    Smartphone biosensors could be cost-effective, portable instruments to be used for the readout of liquid colorimetric assays. However, current reported smartphone colorimetric readers have relied on photos of liquid assays captured using a camera, and then analyzed using software programs. This approach results in a relatively low accuracy and low generality. In this work, we reported a novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays. The portable and low-cost ($0.15) reader utilized a simplified electronic and light path design. Furthermore, our reported smartphone colorimetric reader can be compatible with different smartphones. As a proof of principle, the utility of this device was demonstrated using it in conjunction with an enzyme-linked immunosorbent assay to detect zearalenone. Results were consistent with those obtained using a professional microplate reader. The developed smartphone colorimetric reader was capable of providing scalable, cost-effective, and accurate results for liquid colorimetric assays that related to clinical diagnoses, environment pollution, and food testing. Graphical abstract A novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays.

  3. Pigging the unpiggable: a total integrated maintenance approach of the Progreso Process Pipelines in Yucatan, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Graciano, Luis [PEMEX Refinacion, Mexico, MX (Mexico); Gonzalez, Oscar L. [NDT Systems and Services, Stutensee (Germany)

    2009-07-01

    Pemex Refinacion and NDT Systems and Services, executed a Total Integrated Maintenance Program of the Process Pipeline System in the Yucatan Peninsula in Mexico, in order to modernize, enhance and bring the pipeline system up to the best industry standards and ensure the integrity, reliability and safe operation of the system. This approach consisted in using multi-diameter ultrasonic inspection technology to determine the current status of the pipelines, repair every 'integrity diminishing' feature present on the system and establish a Certified Maintenance Program to ensure the future reliability and safety of the pipelines. Due to the complex nature of the pipeline construction, dated from 1984, several special modifications, integrations and solutions were necessary to improve the in line inspection survey as for all traditionally unpiggable systems. The Progreso Pipeline System consists in 3 major pipelines which transport diesel, jet fuel and gasoline respectively. The outside diameter of two pipelines varies along its length between 12 inches - 14 inches - 16 inches, making the inspection survey more difficult and particularly demanding an Inspection Tool solution. It is located on the coast of the Yucatan Peninsula, at the Mexican Caribbean, and its main purpose is to transport the product from the docked tanker ships to the Pemex Storage and Distribution Terminal. (author)

  4. Integrated and Total HIV-1 DNA Predict Ex Vivo Viral Outgrowth.

    Directory of Open Access Journals (Sweden)

    Maja Kiselinova

    2016-03-01

    Full Text Available The persistence of a reservoir of latently infected CD4 T cells remains one of the major obstacles to cure HIV. Numerous strategies are being explored to eliminate this reservoir. To translate these efforts into clinical trials, there is a strong need for validated biomarkers that can monitor the reservoir over time in vivo. A comprehensive study was designed to evaluate and compare potential HIV-1 reservoir biomarkers. A cohort of 25 patients, treated with suppressive antiretroviral therapy was sampled at three time points, with median of 2.5 years (IQR: 2.4-2.6 between time point 1 and 2; and median of 31 days (IQR: 28-36 between time point 2 and 3. Patients were median of 6 years (IQR: 3-12 on ART, and plasma viral load (<50 copies/ml was suppressed for median of 4 years (IQR: 2-8. Total HIV-1 DNA, unspliced (us and multiply spliced HIV-1 RNA, and 2LTR circles were quantified by digital PCR in peripheral blood, at 3 time points. At the second time point, a viral outgrowth assay (VOA was performed, and integrated HIV-1 DNA and relative mRNA expression levels of HIV-1 restriction factors were quantified. No significant change was found for long- and short-term dynamics of all HIV-1 markers tested in peripheral blood. Integrated HIV-1 DNA was associated with total HIV-1 DNA (p<0.001, R² = 0.85, us HIV-1 RNA (p = 0.029, R² = 0.40, and VOA (p = 0.041, R2 = 0.44. Replication-competent virus was detected in 80% of patients by the VOA and it correlated with total HIV-1 DNA (p = 0.039, R² = 0.54. The mean quantification difference between Alu-PCR and VOA was 2.88 log10, and 2.23 log10 between total HIV-1 DNA and VOA. The levels of usHIV-1 RNA were inversely correlated with mRNA levels of several HIV-1 restriction factors (TRIM5α, SAMHD1, MX2, SLFN11, pSIP1. Our study reveals important correlations between the viral outgrowth and total and integrated HIV-1 DNA measures, suggesting that the total pool of HIV-1 DNA may predict the size of the

  5. Total luminous flux measurement for flexible surface sources with an integrating sphere photometer

    International Nuclear Information System (INIS)

    Yu, Hsueh-Ling; Liu, Wen-Chun

    2014-01-01

    Applying an integrating sphere photometer for total luminous flux measurement is a widely used method. However, the measurement accuracy depends on the spatial uniformity of the integrating sphere, especially when the test sample has a different light distribution from that of the standard source. Therefore, spatial correction is needed to eliminate the effect caused by non-uniformity. To reduce the inconvenience of spatial correction but retain the measurement accuracy, a new type of working standard is designed for flexible and curved surface sources. Applying this new type standard source, the measurement deviation due to different orientations is reduced by an order of magnitude compared with using a naked incandescent lamp as the standard source. (paper)

  6. Enchanced total dose damage in junction field effect transistors and related linear integrated circuits

    International Nuclear Information System (INIS)

    Flament, O.; Autran, J.L.; Roche, P.; Leray, J.L.; Musseau, O.

    1996-01-01

    Enhanced total dose damage of Junction Field-effect Transistors (JFETs) due to low dose rate and/or elevated temperature has been investigated for elementary p-channel structures fabricated on bulk and SOI substrates as well as for related linear integrated circuits. All these devices were fabricated with conventional junction isolation (field oxide). Large increases in damage have been revealed by performing high temperature and/or low dose rate irradiations. These results are consistent with previous studies concerning bipolar field oxides under low-field conditions. They suggest that the transport of radiation-induced holes through the oxide is the underlying mechanism. Such an enhanced degradation must be taken into account for low dose rate effects on linear integrated circuits

  7. Total integrated performance excellence system (TIPES): A true north direction for a clinical trial support center.

    Science.gov (United States)

    Sather, Mike R; Parsons, Sherry; Boardman, Kathy D; Warren, Stuart R; Davis-Karim, Anne; Griffin, Kevin; Betterton, Jane A; Jones, Mark S; Johnson, Stanley H; Vertrees, Julia E; Hickey, Jan H; Salazar, Thelma P; Huang, Grant D

    2018-03-01

    This paper presents the quality journey taken by a Federal organization over more than 20 years. These efforts have resulted in the implementation of a Total Integrated Performance Excellence System (TIPES) that combines key principles and practices of established quality systems. The Center has progressively integrated quality system frameworks including the Malcom Baldrige National Quality Award (MBNQA) Framework and Criteria for Performance Excellence, ISO 9001, and the Organizational Project Management Maturity Model (OPM3), as well as supplemental quality systems of ISO 15378 (packaging for medicinal products) and ISO 21500 (guide to project management) to systematically improve all areas of operations. These frameworks were selected for applicability to Center processes and systems, consistency and reinforcement of complimentary approaches, and international acceptance. External validations include the MBNQA, the highest quality award in the US, continued registration and conformance to ISO standards and guidelines, and multiple VA and state awards. With a focus on a holistic approach to quality involving processes, systems and personnel, this paper presents activities and lessons that were critical to building TIPES and establishing the quality environment for conducting clinical research in support of Veterans and national health care.

  8. Total integrated performance excellence system (TIPES: A true north direction for a clinical trial support center

    Directory of Open Access Journals (Sweden)

    Mike R. Sather

    2018-03-01

    Full Text Available This paper presents the quality journey taken by a Federal organization over more than 20 years. These efforts have resulted in the implementation of a Total Integrated Performance Excellence System (TIPES that combines key principles and practices of established quality systems. The Center has progressively integrated quality system frameworks including the Malcom Baldrige National Quality Award (MBNQA Framework and Criteria for Performance Excellence, ISO 9001, and the Organizational Project Management Maturity Model (OPM3, as well as supplemental quality systems of ISO 15378 (packaging for medicinal products and ISO 21500 (guide to project management to systematically improve all areas of operations. These frameworks were selected for applicability to Center processes and systems, consistency and reinforcement of complimentary approaches, and international acceptance. External validations include the MBNQA, the highest quality award in the US, continued registration and conformance to ISO standards and guidelines, and multiple VA and state awards. With a focus on a holistic approach to quality involving processes, systems and personnel, this paper presents activities and lessons that were critical to building TIPES and establishing the quality environment for conducting clinical research in support of Veterans and national health care.

  9. Integrating total quality management principles with the requirements of DOE Order 5700.6C

    Energy Technology Data Exchange (ETDEWEB)

    Hedges, D. [Scientific Ecology Group, Inc. (United States)

    1993-03-01

    The Department of Energy has recently required its field offices, contractors, and subcontractors to implement DOE Order 5700.6C, ``Quality Assurance,`` for all work on waste management contracts. The order restructures the 18 criteria of NQA-1 and focuses on the role of management in achieving and assuring quality, performance of activities to achieve and assure quality, and management`s assessment of its performance for the purpose of identifying improvements to be made. The DOE order also introduces elements of the total quality management (TQM) philosophy, which were not present in DOE Order 5700.6B. The research community within DOE has recently issued a document entitled DOE Order 5700.6C Implementation Guide, which is more explicit about the integration of TQM principles with the implementation of DOE Order 5700.6C in research facilities. The Environmental Protection Agency is sponsoring a quality assurance standard (ANSI/ASQC E-4) to replace EPA`s QAMS 005/80. The new standard is consistent with DOE Order 5700.6C, and it also stresses the integration of TQM principles within the quality assurance process. This paper discusses the intent and philosophy of the 10 criteria of the new DOE order, the status of ANSI/ASQC E-4, and how to effectively integrate TQM principles into the quality assurance process as the conversion is made from NQA-1 to DOE Order 5700.6C. The purpose and value of DOE Order 5700.6C Implementation Guide for research will also be discussed.

  10. Maximized liquid radwaste volume reduction through a total integrated process: A new technology success story

    International Nuclear Information System (INIS)

    Rae, G.A.

    1996-01-01

    A fundamental nuclear industry goal is the minimization of the generation of radioactive waste. This goal has been dramatically reinforced over the past few years due to the spiraling increased costs of both commercial and DOE disposal. To assist in meeting these goals and reducing the industry's costs, NUKEM initiated a new technology program to maximize the reduction of liquid radwaste through the use of a systematic approach or TIPS (Total Integrated Process System). This concept evaluates the total life cycle of various technologies in a combination that results in the final waste form being minimized to the pure solids content of the waste stream. Additionally, it allows for a final waste form that maximizes the utilization of the waste package and is conditioned to be readily acceptable to additional processing to meet new waste form requirements at future disposal sites, should interim storage of the waste be required. The TIPS, although first introduced at commercial facilities, has broad applications for DOE's liquid waste streams

  11. Integral elastic, electronic-state, ionization, and total cross sections for electron scattering with furfural

    Science.gov (United States)

    Jones, D. B.; da Costa, R. F.; Varella, M. T. do N.; Bettega, M. H. F.; Lima, M. A. P.; Blanco, F.; García, G.; Brunger, M. J.

    2016-04-01

    We report absolute experimental integral cross sections (ICSs) for electron impact excitation of bands of electronic-states in furfural, for incident electron energies in the range 20-250 eV. Wherever possible, those results are compared to corresponding excitation cross sections in the structurally similar species furan, as previously reported by da Costa et al. [Phys. Rev. A 85, 062706 (2012)] and Regeta and Allan [Phys. Rev. A 91, 012707 (2015)]. Generally, very good agreement is found. In addition, ICSs calculated with our independent atom model (IAM) with screening corrected additivity rule (SCAR) formalism, extended to account for interference (I) terms that arise due to the multi-centre nature of the scattering problem, are also reported. The sum of those ICSs gives the IAM-SCAR+I total cross section for electron-furfural scattering. Where possible, those calculated IAM-SCAR+I ICS results are compared against corresponding results from the present measurements with an acceptable level of accord being obtained. Similarly, but only for the band I and band II excited electronic states, we also present results from our Schwinger multichannel method with pseudopotentials calculations. Those results are found to be in good qualitative accord with the present experimental ICSs. Finally, with a view to assembling a complete cross section data base for furfural, some binary-encounter-Bethe-level total ionization cross sections for this collision system are presented.

  12. Integral elastic, electronic-state, ionization, and total cross sections for electron scattering with furfural

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D. B. [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001 (Australia); Costa, R. F. da [Instituto de Física “Gleb Wataghin,” Universidade Estadual de Campinas, Campinas, 13083-859 São Paulo (Brazil); Departamento de Física, Universidade Federal do Espírito Santo, 29075-910, Vitória, Espírito Santo (Brazil); Varella, M. T. do N. [Instituto de Física, Universidade de São Paulo, CP 66318, 05315-970 São Paulo (Brazil); Bettega, M. H. F. [Departamento de Física, Universidade Federal do Paraná, CP 19044, 81531-990 Curitiba, Paraná (Brazil); Lima, M. A. P. [Instituto de Física “Gleb Wataghin,” Universidade Estadual de Campinas, Campinas, 13083-859 São Paulo (Brazil); Blanco, F. [Departamento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid E-28040 (Spain); García, G. [Instituto de Física Fundamental, CSIC, Serrano 113-bis, 28006 Madrid (Spain); Brunger, M. J., E-mail: Michael.Brunger@flinders.edu.au [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, South Australia 5001 (Australia); Institute of Mathematical Sciences, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2016-04-14

    We report absolute experimental integral cross sections (ICSs) for electron impact excitation of bands of electronic-states in furfural, for incident electron energies in the range 20–250 eV. Wherever possible, those results are compared to corresponding excitation cross sections in the structurally similar species furan, as previously reported by da Costa et al. [Phys. Rev. A 85, 062706 (2012)] and Regeta and Allan [Phys. Rev. A 91, 012707 (2015)]. Generally, very good agreement is found. In addition, ICSs calculated with our independent atom model (IAM) with screening corrected additivity rule (SCAR) formalism, extended to account for interference (I) terms that arise due to the multi-centre nature of the scattering problem, are also reported. The sum of those ICSs gives the IAM-SCAR+I total cross section for electron–furfural scattering. Where possible, those calculated IAM-SCAR+I ICS results are compared against corresponding results from the present measurements with an acceptable level of accord being obtained. Similarly, but only for the band I and band II excited electronic states, we also present results from our Schwinger multichannel method with pseudopotentials calculations. Those results are found to be in good qualitative accord with the present experimental ICSs. Finally, with a view to assembling a complete cross section data base for furfural, some binary-encounter-Bethe-level total ionization cross sections for this collision system are presented.

  13. Integral elastic, electronic-state, ionization, and total cross sections for electron scattering with furfural

    International Nuclear Information System (INIS)

    Jones, D. B.; Costa, R. F. da; Varella, M. T. do N.; Bettega, M. H. F.; Lima, M. A. P.; Blanco, F.; García, G.; Brunger, M. J.

    2016-01-01

    We report absolute experimental integral cross sections (ICSs) for electron impact excitation of bands of electronic-states in furfural, for incident electron energies in the range 20–250 eV. Wherever possible, those results are compared to corresponding excitation cross sections in the structurally similar species furan, as previously reported by da Costa et al. [Phys. Rev. A 85, 062706 (2012)] and Regeta and Allan [Phys. Rev. A 91, 012707 (2015)]. Generally, very good agreement is found. In addition, ICSs calculated with our independent atom model (IAM) with screening corrected additivity rule (SCAR) formalism, extended to account for interference (I) terms that arise due to the multi-centre nature of the scattering problem, are also reported. The sum of those ICSs gives the IAM-SCAR+I total cross section for electron–furfural scattering. Where possible, those calculated IAM-SCAR+I ICS results are compared against corresponding results from the present measurements with an acceptable level of accord being obtained. Similarly, but only for the band I and band II excited electronic states, we also present results from our Schwinger multichannel method with pseudopotentials calculations. Those results are found to be in good qualitative accord with the present experimental ICSs. Finally, with a view to assembling a complete cross section data base for furfural, some binary-encounter-Bethe-level total ionization cross sections for this collision system are presented.

  14. Total integrated energy system (TIES) feasibility analysis for the downtown redevelopment project, Pasadena, California

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-04-01

    The purpose of this study is to determine the most desirable method of serving the energy needs of a commercial development to be constructed in Pasadena, California. The factors that determine maximum desirability consist of the following: (1) maximum economic benefit to the energy user and to the surrounding community; (2) minimum usage of energy by both the energy user and the surrounding community; and (3) minimum introduction of pollutants into the community. The methods studied were the Total Integrated Energy System (TIES) concept in several configurations. The TIES concept differs from the ''total energy concept'' in the respect that the electric power output of the local power generation plant goes into the utility company distribution grid, rather than to the user. The user is served power from the grid, as with a conventional system, but also receives heating and cooling media produced from power generation by-product heat from the TIES plant. The effect of this concept is that a very large source-sink for electric energy is provided by the utility company grid. This, in turn, permits the plant to operate in response to instantaneous thermal demand, rather than instantaneous power demand. No auxiliary firing is ever required. No waste of unneeded by-product energy to atmosphere ever occurs. Balance is achieved by either delivering excess power into the grid or by withdrawing power production deficiency from the grid. Near-optimum efficiency is achieved during all operating conditions. There is no need whatsoever for the power-generating plant to be sized to meet the power demand, since it seldom, if ever, tracks the power demand. Sizing of the electric generation is solely a function of economics and the demand for waste heat.

  15. Redesigning the work system of rubber industries based on total ergonomics and ergo-micmac integration

    Science.gov (United States)

    Setiawan, H.

    2018-01-01

    The factory capacity achievement and the bottleneck reduction of production process at wet-blanket workstations are influenced by the balance of life quality rates and worker’s productivity, along with the worker’s ability and limitations, tasks, organization and work environment. The life quality of workers is indicated by: the reduction of workload, and fatigue. Meanwhile, work productivity is measured by increasing production results per work shift. The optimization of the quality of life and productivity of workers is achieved by redesigning the system and workstations based on ergonomics integrating Total Ergonomics with Ergo-MicMac (Micro Ergonomics and Macro Ergonomics), which includes redesigning wet-blanket folding worktable, regulating the system pattern of working in pairs, giving official break time, giving extra nutritious intakes such as sweet tea and snack Pempek, giving personal protective equipments, and redesigning physical working environments.This study was an experimental study, with treatment by subject design involving 30 workers sampled at a workstation condition before and after Ergonomics based redesign. The findings and conclusions of the study were derived from the reduction of the workload by 16.06%, fatigue by 18.84% and the increase of production results per work shift by 20.29%.

  16. STEAM GENERATOR TUBE INTEGRITY ANALYSIS OF A TOTAL LOSS OF ALL HEAT SINKS ACCIDENT FOR WOLSONG NPP UNIT 1

    Directory of Open Access Journals (Sweden)

    HEOK-SOON LIM

    2014-02-01

    Full Text Available A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS and the steam generator (SG secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident.

  17. Steam Generator Tube Integrity Analysis of A Total Loss of all Heat Sinks Accident for Wolsong NPP Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Heoksoon; Song, Taeyoung; Chi, Moongoo [Korea Htydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of); Kim, Seoungrae [Nuclear Engineering Service and Solution, Daejeon (Korea, Republic of)

    2014-02-15

    A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV) become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS) and the steam generator (SG) secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident.

  18. Steam Generator Tube Integrity Analysis of A Total Loss of all Heat Sinks Accident for Wolsong NPP Unit 1

    International Nuclear Information System (INIS)

    Lim, Heoksoon; Song, Taeyoung; Chi, Moongoo; Kim, Seoungrae

    2014-01-01

    A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV) become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS) and the steam generator (SG) secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident

  19. Optimization of total arc degree for stereotactic radiotherapy by using integral biologically effective dose and irradiated volume

    International Nuclear Information System (INIS)

    Lim, Do Hoon; Kim, Dae Yong; Lee, Myung Za; Chun, Ha Chung

    2001-01-01

    To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. With Xknife-3 planning system and 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, 100 deg, 200 deg, 300 deg, 400 deg, 500 deg, 600 deg, of total arc degrees, and 30 deg or 45 deg of arc intervals were used. After the completion of planning, the plans were compared each other using V 50 (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. At 30 deg of arc interval, the values of V 50 had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval, up to 400 deg of total arc degree, the values of V 50 decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. At 30 deg of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with 50 and 60 mm of collimator diameters, up to 400 deg of total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. In the stereotactic radiotherapy planning for brain lesions, planning with 400 deg of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of 500 deg and 600 deg of total arc degrees make the increase of V 50 and integral biologically effective dose, Therefore stereotactic radiotherapy planning using 400 deg of total arc degree can increase the therapeutic ratio and produce the effective outcome

  20. Dynamic integration of residential building design and green energies : the Bireth approach : building integrated renewable energy total harvest approach

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, K.P. [Hong Kong Univ., Hong Kong (China). Dept. of Architecture; Luk, C.L.P. [Chu Hai College of Higher Education, Hong Kong (China). Dept. of Architecture; Wong, S.T. [Hong Kong Univ., Hong Kong (China). Div. of Arts and Humanities, SPACE; Chung, S.L.; Fung, K.S.; Leung, M.F. [Hong Kong Inst. of Vocational Education, Hong Kong (China)

    2006-07-01

    Renewable energy sources that are commonly used in buildings include solar energy, wind energy and rainwater collection. High quality environmentally responsive residential buildings are designed to provide good insulation in winter and solar shading in summer. However, this study demonstrated that the green energy design in residential buildings is not usually well integrated. For example, windows with clear double or triple glazed glass, allow good penetration of sunlight during the day in winter, but are not further dynamically insulated for when the sun goes down to avoid heat loss from the building. Additionally, good solar static shading devices often block much needed daylight on cloudy winter days. These examples emphasize the lack of an integrated approach to gain the best advantage of green energies and to minimize energy costs in residential buildings. This study addressed issues facing the integrated approach with particular reference to the design of a small residential building in rural Beijing. The design included a new approach for interpreting a traditional Beijing court yard house in the modern Beijing rural context, while integrating multi-responding innovative green energy applications derived from first principles. This paper also presented a proposal for a village house in Hong Kong to harvest as much renewable energies as possible, primarily wind energy and solar energy, that come into contact with the building. The purpose was to work towards a renewable energy approach for buildings, namely the Bireth approach, which will benefit practically all houses by making them zero energy houses. The paper described the feasibility of integrating renewable energies in buildings to fulfill performance requirements such improving ventilation, providing warm interiors, drying clothes, or storing solar and wind energies into power batteries. The challenges facing the development of a proposed micro solar hot air turbine were also presented. 15 refs., 6

  1. Is Yang-Mills equation a totally integrable system. Lecture III

    International Nuclear Information System (INIS)

    Chau Wang, L.L.

    1981-01-01

    Topics covered include: loop-space formulation of gauge theory - loop-space chiral equation; two dimensional chiral equation - conservation laws, linear system and integrability; and parallel development for the loop-space chiral equation - subtlety

  2. Integrated Data Fusion and Mining Techniques for Monitoring Total Organic Carbon Concentrations in a Lake

    Science.gov (United States)

    Total organic carbon (TOC) in surface waters, markedly of seasonal variations, is a known precursor of disinfection byproducts such as Total Trihalomethanes (TTHM) in drinking water treatment. Real-time knowledge of TOC distribution in source water can help treatment operation to...

  3. On-site energy consumption at softwood sawmills in Montana

    Science.gov (United States)

    Dan Loeffler; Nathaniel Anderson; Todd A. Morgan; Colin B. Sorenson

    2016-01-01

    Total on-site energy requirements for wood product manufacturing are generally not well understood or publicly available, particularly at subregional scales, such as the state level. This article uses a mail survey of softwood sawmills in Montana to develop a profile of all on-site energy consumption. Energy use is delineated by fuel type on a production basis...

  4. Application of the integrated analysis of safety (ISA) to sequences of Total loss of feed water in a PWR Reactor

    International Nuclear Information System (INIS)

    Moreno Chamorro, P.; Gallego Diaz, C.

    2011-01-01

    The main objective of this work is to show the current status of the implementation of integrated analysis of safety (ISA) methodology and its SCAIS associated tool (system of simulation codes for ISA) to the sequence analysis of total loss of feedwater in a PWR reactor model Westinghouse of three loops with large, dry containment.

  5. Integrated Autopilot/Autothrottle Based on a Total Energy Control Concept: Design and Evaluation of Additional Autopilot Modes

    Science.gov (United States)

    Bruce, Kevin R.

    1988-01-01

    An integrated autopilot/autothrottle system was designed using a total energy control design philosophy. This design ensures that the system can differentiate between maneuvers requiring a change in thrust to accomplish a net energy change, and those maneuvers which only require elevator control to redistribute energy. The system design, the development of the system, and a summary of simulation results are defined.

  6. La auditoría integral o total informe final del proyecto

    OpenAIRE

    Casal, Armando Miguel

    1999-01-01

    Se propone dar una perspectiva de conjunto de la auditoría integral, considerando que dicha expresión no está todavía comprendida en forma adecuada. Dicha auditoría representa un concepto en evolución a lo largo del tiempo, que incluye sus diferentes enfoques y la necesidad de su aplicación en los distintos sectores de la economía, tanto públicos, como privados o mixtos.La auditoría integral fue desarrollada originalmente en el sector público, para que los auditores independientes, proporcion...

  7. CTBT on-site inspections

    Science.gov (United States)

    Zucca, J. J.

    2014-05-01

    On-site inspection (OSI) is a critical part of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The OSI verification regime provides for international inspectors to make a suite of measurements and observations on site at the location of an event of interest. The other critical component of the verification regime is the International Monitoring System (IMS), which is a globally distributed network of monitoring stations. The IMS along with technical monitoring data from CTBT member countries, as appropriate, will be used to trigger an OSI. After the decision is made to carry out an OSI, it is important for the inspectors to deploy to the field site rapidly to be able to detect short-lived phenomena such as the aftershocks that may be observable after an underground nuclear explosion. The inspectors will be on site from weeks to months and will be working with many tens of tons of equipment. Parts of the OSI regime will be tested in a field exercise in the country of Jordan late in 2014. The build-up of the OSI regime has been proceeding steadily since the CTBT was signed in 1996 and is on track to becoming a deterrent to someone considering conducting a nuclear explosion in violation of the Treaty.

  8. On integrating modeling software for application to total-system performance assessment

    International Nuclear Information System (INIS)

    Lewis, L.C.; Wilson, M.L.

    1994-05-01

    We examine the processes and methods used to facilitate collaboration in software development between two organizations at separate locations -- Lawrence Livermore National Laboratory (LLNL) in California and Sandia National Laboratories (SNL) in New Mexico. Our software development process integrated the efforts of these two laboratories. Software developed at LLNL to model corrosion and failure of waste packages and subsequent releases of radionuclides was incorporated as a source term into SNLs computer models for fluid flow and radionuclide transport through the geosphere

  9. Integrating a Social Behavior Intervention during Small Group Academic Instruction Using a Total Group Criterion Intervention

    Science.gov (United States)

    Rodriguez, Billie Jo; Anderson, Cynthia M.

    2014-01-01

    Total group contingencies, a variation of interdependent group contingencies, provide educators with an efficient and effective mechanism to improve social behavior and increase academic skills. Their utility has not been examined in small educational groups. This is unfortunate as supplemental instruction frequently is delivered in small group…

  10. Total elimination of sampling errors in polarization imagery obtained with integrated microgrid polarimeters.

    Science.gov (United States)

    Tyo, J Scott; LaCasse, Charles F; Ratliff, Bradley M

    2009-10-15

    Microgrid polarimeters operate by integrating a focal plane array with an array of micropolarizers. The Stokes parameters are estimated by comparing polarization measurements from pixels in a neighborhood around the point of interest. The main drawback is that the measurements used to estimate the Stokes vector are made at different locations, leading to a false polarization signature owing to instantaneous field-of-view (IFOV) errors. We demonstrate for the first time, to our knowledge, that spatially band limited polarization images can be ideally reconstructed with no IFOV error by using a linear system framework.

  11. TotalReCaller: improved accuracy and performance via integrated alignment and base-calling.

    Science.gov (United States)

    Menges, Fabian; Narzisi, Giuseppe; Mishra, Bud

    2011-09-01

    Currently, re-sequencing approaches use multiple modules serially to interpret raw sequencing data from next-generation sequencing platforms, while remaining oblivious to the genomic information until the final alignment step. Such approaches fail to exploit the full information from both raw sequencing data and the reference genome that can yield better quality sequence reads, SNP-calls, variant detection, as well as an alignment at the best possible location in the reference genome. Thus, there is a need for novel reference-guided bioinformatics algorithms for interpreting analog signals representing sequences of the bases ({A, C, G, T}), while simultaneously aligning possible sequence reads to a source reference genome whenever available. Here, we propose a new base-calling algorithm, TotalReCaller, to achieve improved performance. A linear error model for the raw intensity data and Burrows-Wheeler transform (BWT) based alignment are combined utilizing a Bayesian score function, which is then globally optimized over all possible genomic locations using an efficient branch-and-bound approach. The algorithm has been implemented in soft- and hardware [field-programmable gate array (FPGA)] to achieve real-time performance. Empirical results on real high-throughput Illumina data were used to evaluate TotalReCaller's performance relative to its peers-Bustard, BayesCall, Ibis and Rolexa-based on several criteria, particularly those important in clinical and scientific applications. Namely, it was evaluated for (i) its base-calling speed and throughput, (ii) its read accuracy and (iii) its specificity and sensitivity in variant calling. A software implementation of TotalReCaller as well as additional information, is available at: http://bioinformatics.nyu.edu/wordpress/projects/totalrecaller/ fabian.menges@nyu.edu.

  12. Training Artisans On-Site

    Directory of Open Access Journals (Sweden)

    Edoghogho Ogbeifun

    2011-09-01

    Full Text Available The decline in apprenticeship in both the public and private sectors, the increasing use of sub-contractors as well as the uncoordinated approach in the informal sector are contributing factors to the shortage of skilled artisans in the construction industry. Artisans training can be introduced and implemented through the adoption of progressive implementation of construction processes commencing work from areas requiring low skill demands to areas of high skill demand. The success of this principle hinges on the collaborative effort of the key project stakeholders. The client should be willing to absorb extra cost and delays in the project; the design and contract documentation should facilitate on-site training, and  the consultant actively guide the contractor and the construction processes to achieve the training objectives. The exploratory research method was adopted in this study and research revealed that this principle was used in a project in the UK and in the development of infrastructure in the tourism industry of South Africa .It is being recommended that the principle be adapted by the public sector for the development of small size infrastructures that can be repeated in many places. This will boost the quality and quantity of artisans, enhance employability, reduce rural urban migration and alleviate poverty.Keywords: Skilled artisans, on-site training, progressive construction processes, project stakeholders, contract documentation. 

  13. QUALITY MANAGEMENT AND INTEGRATED TOTAL QUALITY IN SPANISH MINING: RESULTS OF AN EMPIRICAL STUDY

    OpenAIRE

    CARMEN ESCANCIANO; FRANCISCO-JAVIER IGLESIAS-RODRÍGUEZ

    2012-01-01

    En este artículo se presentan y analizan los resultados de un estudio empírico realizado en España entre empresas mineras certificadas ISO 9001. El objetivo perseguido es doble: en primer lugar, reflexionar sobre la situación de la gestión de calidad en la minería española; en segundo término, valorar en qué medida la posesión de un sistema de gestión de calidad constituye un pilar a partir del cual iniciar la andadura hacia la calidad total integrada con otros sistemas de gestión tan importa...

  14. QUALITY MANAGEMENT AND INTEGRATED TOTAL QUALITY IN SPANISH MINING: RESULTS OF AN EMPIRICAL STUDY

    Directory of Open Access Journals (Sweden)

    CARMEN ESCANCIANO

    2012-01-01

    Full Text Available En este artículo se presentan y analizan los resultados de un estudio empírico realizado en España entre empresas mineras certificadas ISO 9001. El objetivo perseguido es doble: en primer lugar, reflexionar sobre la situación de la gestión de calidad en la minería española; en segundo término, valorar en qué medida la posesión de un sistema de gestión de calidad constituye un pilar a partir del cual iniciar la andadura hacia la calidad total integrada con otros sistemas de gestión tan importantes en este sector industrial como el de la gestión ambiental o la gestión de la seguridad y salud laboral.

  15. Simulation of worst-case operating conditions for integrated circuits operating in a total dose environment

    International Nuclear Information System (INIS)

    Bhuva, B.L.

    1987-01-01

    Degradations in the circuit performance created by the radiation exposure of integrated circuits are so unique and abnormal that thorough simulation and testing of VLSI circuits is almost impossible, and new ways to estimate the operating performance in a radiation environment must be developed. The principal goal of this work was the development of simulation techniques for radiation effects on semiconductor devices. The mixed-mode simulation approach proved to be the most promising. The switch-level approach is used to identify the failure mechanisms and critical subcircuits responsible for operational failure along with worst-case operating conditions during and after irradiation. For precise simulations of critical subcircuits, SPICE is used. The identification of failure mechanisms enables the circuit designer to improve the circuit's performance and failure-exposure level. Identification of worst-case operating conditions during and after irradiation reduces the complexity of testing VLSI circuits for radiation environments. The results of test circuits for failure simulations using a conventional simulator and the new simulator showed significant time savings using the new simulator. The savings in simulation time proved to be circuit topology-dependent. However, for large circuits, the simulation time proved to be orders of magnitude smaller than simulation time for conventional simulators

  16. Estimation of Total Glomerular Number Using an Integrated Disector Method in Embryonic and Postnatal Kidneys

    Directory of Open Access Journals (Sweden)

    Michel G Arsenault

    2014-06-01

    Full Text Available Congenital Anomalies of the Kidney and Urinary Tract (CAKUT are a polymorphic group of clinical disorders comprising the major cause of renal failure in children. Included within CAKUT is a wide spectrum of developmental malformations ranging from renal agenesis, renal hypoplasia and renal dysplasia (maldifferentiation of renal tissue, each characterized by varying deficits in nephron number. First presented in the Brenner Hypothesis, low congenital nephron endowment is becoming recognized as an antecedent cause of adult-onset hypertension, a leading cause of coronary heart disease, stroke, and renal failure in North America. Genetic mouse models of impaired nephrogenesis and nephron endowment provide a critical framework for understanding the origins of human kidney disease. Current methods to quantitate nephron number include (i acid maceration (ii estimation of nephron number from a small number of tissue sections (iii imaging modalities such as MRI and (iv the gold standard physical disector/fractionator method. Despite its accuracy, the physical disector/fractionator method is rarely employed because it is labour-intensive, time-consuming and costly to perform. Consequently, less rigourous methods of nephron estimation are routinely employed by many laboratories. Here we present an updated, digitized version of the physical disector/fractionator method using free open source Fiji software, which we have termed the integrated disector method. This updated version of the gold standard modality accurately, rapidly and cost-effectively quantitates nephron number in embryonic and post-natal mouse kidneys, and can be easily adapted for stereological measurements in other organ systems.

  17. Integration of Public Finance Administration into ISO 9001 Total Quality Management

    Directory of Open Access Journals (Sweden)

    Hakan KİTAPÇI

    2012-06-01

    Full Text Available In Chronology; although they show different progress from each others, today Total Quality Management (TQM and Internal Auditing are two management concepts that are in mutual interaction and provide help for development of each other. TQM is a human based management concept that aims to increase customer satisfaction and enhance quality with decreasing cost in organizations. Internal Auditing is an independent, objective assurance and consultancy action on organization’s efficiency, productivity and accordance with laws and regulations. In this study; interrelation of public financial administration and TQM, how they interact each other and their size are displayed with searching lots of related scientific resources and a sample from public is given about application. In this study internal auditing is accepted as a management philosophy which has an important in TQM, and also which Exhausted risk, IT systems, internal Auditing Process, relationship with environment, performance and quality. At the end of study we can easily say that the new financial system realizes the ISO 9001 standards a high degree.

  18. Integration into plant biology and soil science has provided insights into the total environment.

    Science.gov (United States)

    Shao, Hongbo; Lu, Haiying; Xu, Gang; Marian, Brestic

    2017-02-01

    The total environment includes 5 closely-linking circles, in which biosphere and lithosphere are the active core. As global population increases and urbanization process accelerates, arable land is gradually decreasing under global climate change and the pressure of various types of environmental pollution. This case is especially for China. Land is the most important resources for human beings' survival. How to increase and manage arable land is the key for sustainable agriculture development. China has extensive marshy land that can be reclamated for the better potential land resources under the pre- condition of protecting the environment, which will be a good way for enlarging globally and managing arable land. Related studies have been conducted in China for the past 30years and now many results with obvious practical efficiency have been obtained. For summarizing these results, salt-soil will be the main target and related contents such as nutrient transport, use types, biodiversity and interactions with plants from molecular biology to ecology will be covered, in which the interactions among biosphere, lithosphere, atmosphere and anthroposphere will be focused on. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. A totally heat-integrated distillation column (THIDiC) - the effect of feed pre-heating by distillate

    Energy Technology Data Exchange (ETDEWEB)

    Huang Kejin [School of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029 (China)], E-mail: huangkj@mail.buct.edu.cn; Shan Lan; Zhu Qunxiong [School of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029 (China); Qian Jixin [School of Information Science and Technology, Zhejiang University, Zhejiang 300027 (China)

    2008-06-15

    An ideal heat-integrated distillation column (ideal HIDiC) is characterized by external zero-reflux and zero-reboil ratio operation. Since the distillate is a high-pressure vapor phase flow, it can be used to pre-heat the feed to be separated, thereby giving rise to a totally heat-integrated distillation column (THIDiC). Although the THIDiC is more thermodynamically efficient than the ideal HIDiC, it is found that the heat integration between the distillate and feed turns it into an open-loop integrating process and poses additional difficulties to process operation. Therefore, a careful decision must be made on the selection between the ideal HIDiC and the THIDiC during process development. In this paper, separation of a binary equimolar mixture of benzene and toluene is selected as an illustrative example. Both process design and operability analysis are conducted, with special emphasis focused on the characteristics of feed pre-heating with distillate. The results obtained show deep insight into the design and operation of the THIDiC.

  20. A totally heat-integrated distillation column (THIDiC) - the effect of feed pre-heating by distillate

    International Nuclear Information System (INIS)

    Huang Kejin; Shan Lan; Zhu Qunxiong; Qian Jixin

    2008-01-01

    An ideal heat-integrated distillation column (ideal HIDiC) is characterized by external zero-reflux and zero-reboil ratio operation. Since the distillate is a high-pressure vapor phase flow, it can be used to pre-heat the feed to be separated, thereby giving rise to a totally heat-integrated distillation column (THIDiC). Although the THIDiC is more thermodynamically efficient than the ideal HIDiC, it is found that the heat integration between the distillate and feed turns it into an open-loop integrating process and poses additional difficulties to process operation. Therefore, a careful decision must be made on the selection between the ideal HIDiC and the THIDiC during process development. In this paper, separation of a binary equimolar mixture of benzene and toluene is selected as an illustrative example. Both process design and operability analysis are conducted, with special emphasis focused on the characteristics of feed pre-heating with distillate. The results obtained show deep insight into the design and operation of the THIDiC

  1. 75 FR 879 - National Semiconductor Corporation Arlington Manufacturing Site Including On-Site Leased Workers...

    Science.gov (United States)

    2010-01-06

    ... engaged in activities related to the production of integrated circuits. The company reports that on-site... Corporation Arlington Manufacturing Site Including On-Site Leased Workers From GCA, CMPA (Silverleaf), Custom..., applicable to workers of National Semiconductor Corporation, Arlington Manufacturing Site, including on-site...

  2. Total Integrative Evolutionary Communication

    DEFF Research Database (Denmark)

    Nedergaard Thomsen, Ole; Brier, Søren

    2014-01-01

    ) instinctual-motivational-emotional sign plays (a level which is shared with other animals and is the domain of ethology), and (3) premeditated, intentional symbol-based language games (specifically human unitary thinking-speaking-gesturing, the domain of pragmatics-based functional linguistics...

  3. Prismatic TIR (total internal reflection) low-concentration PV (photovoltaics)-integrated façade for low latitudes

    International Nuclear Information System (INIS)

    Sabry, Mohamed

    2016-01-01

    Low-concentration Façade-integrated Photovoltaic system in the form of TIR (total internal reflection) prismatic segmented façade could play an effective role in reducing the direct component of solar radiation transmitting through buildings, hence reducing both cooling and artificial lighting load on such buildings. A prismatic segmented façade is capable of allowing diffused skylight to transmit through it to the building interior, while preventing most of the direct solar radiation and converting it into clean energy by means of the integrated PV (​photovoltaics) cells. A range of prismatic TIR segmented façades with different head angles has been designed based on the geographical latitude of the chosen location. Each façade configuration is simulated by ray-tracing technique and its performance is investigated against realistic direct solar radiation data in two clear sky days representing summer and winter of the targeted location. Ray tracing simulations revealed that all of the selected configurations could collect most of the direct solar radiation in summer. In contrary, larger head angle of the segmented façade could collect wider intervals around the noon time till reaching a head angle of 23° at which most of the incident direct solar radiation could be collected. - Highlights: • 5 different head angles of prismatic segmented PV-integrated Façade are ray-traced. • Transmitted and PV-collected solar radiation percentages are determined. • DNI daily profiles with associated solar altitudes and azimuth data are simulated. • Expected transmitted and PV collected solar radiation are calculated for the proposed segments.

  4. Radioactive waste on-site storage alternative

    International Nuclear Information System (INIS)

    Dufrane, K.H.

    1983-01-01

    The first, most frequently evaluated approach for the large producer is the construction of a relatively expensive storage building. However, with the likely possibility that at least one disposal site will remain available and the building never used, such expenditures are difficult to justify. A low cost, but effective alternative, is the use of ''On-Site Storage Containers'' (OSSC) when and if required. Radwaste is only stored in the OSSC if a disposal site is not available. A small number of OSSC's would be purchased initially just to assure immediate access to storage. Only in the unlikely event of total disposal sites closure would additional OSSC's have to be obtained and even this is cost effective. With two or three months of storage available on site, production lead time is sufficient for the delivery of additional units at a rate faster than the waste can be produced. The recommended OSSC design would be sized and shielding optimized to meet the needs of the waste generator. Normally, this would duplicate the shipping containers (casks or vans) currently in use. The reinforced concrete design presented is suitable for outside storage, contains a leakproof polyethylene liner and has remote sampling capability. Licensing would be under 10CFR50.59 for interim storage with long-term storage under 10CFR30 not an impossibility. Cost comparisons of this approach vs. building construction show that for a typical reactor plant installation, the OSSC offers direct savings even under the worst case assumption that no disposal sites are available and the time value of money is zero

  5. Application of the integrated analysis of safety (IAS) to sequences of Total loss of feed water in a PWR Reactor; Aplicacion del Analisis Integrado de Seguridad (ISA) a Secuencias de Perdidas Total de Agua de Alimentacion en un Reactor PWR

    Energy Technology Data Exchange (ETDEWEB)

    Moreno Chamorro, P.; Gallego Diaz, C.

    2011-07-01

    The main objective of this work is to show the current status of the implementation of integrated analysis of safety (IAS) methodology and its SCAIS associated tool (system of simulation codes for IAS) to the sequence analysis of total loss of feedwater in a PWR reactor model Westinghouse of three loops with large, dry containment.

  6. Experiences with on-site power sources at KCB

    Energy Technology Data Exchange (ETDEWEB)

    Heijnen, B. M.A. [Borssele Nuclear Power Station, N.V. P.Z.E.M., Postbus 48, 4330 AA Middleburg (Netherlands)

    1986-02-15

    The design of the nuclear power station is of the late sixties. The experiences with the on-site power sources, signal processing and some of the resulting modifications of the design of the power plant are mentioned. In order to let the design satisfy as much as possible present ideas about safety, it was decided to realize a total new and Independent decay heat removal System. With this system a second independent on-site power System is at disposal in case of accident situations. (author)

  7. Effects of total integrated solar radiation on radial fruit cracking in tomato [Lycopersicon esculentum] cultivation under rain shelter in cool uplands

    International Nuclear Information System (INIS)

    Suzuki, T.; Yanase, S.; Enya, T.; Shimazu, T.; Tanaka, I.

    2007-01-01

    This study investigated the cause of radial fruit cracking in tomato cultivation under rain shelter in the cool uplands in Gifu Prefecture. The effect of total integrated radiation using two types of training methods was determined over a three-year period. The percentage of refused radial fruit cracking associated with increased total integrated solar radiation from the young fruit stage to the mature green stage. Fruit cracking occurred in the training method which foliage and fruits received a large amount of light-interception. Also, as for fruits that undergo vigorous enlargement, the frequency of the radial fruit cracking increased

  8. From heat integration targets toward implementation – A TSA (total site analysis)-based design approach for heat recovery systems in industrial clusters

    International Nuclear Information System (INIS)

    Hackl, Roman; Harvey, Simon

    2015-01-01

    The European process industry is facing major challenges to decrease production costs. One strategy to achieve this is by increasing energy efficiency. Single chemical processes are often well-integrated and the tools to target and design such measures are well developed. Site-wide heat integration based on total site analysis tools can be used to identify opportunities to further increase energy efficiency. However, the methodology has to be developed further in order to enable identification of practical heat integration measures in a systematic way. Designing site-wide heat recovery systems across an industrial cluster is complex and involves aspects apart from thermal process and utility flows. This work presents a method for designing a roadmap of heat integration investments based on total site analysis. The method is applied to a chemical cluster in Sweden. The results of the case study show that application of the proposed method can achieve up to 42% of the previously targeted hot utility savings of 129 MW. A roadmap of heat integration systems is suggested, ranging from less complex systems that achieve a minor share of the heat recovery potential to sophisticated, strongly interdependent systems demanding large investments and a high level of collaboration. - Highlights: • Methodology focused on the practical implementation of site-wide heat recovery. • Algorithm to determine a roadmap of heat integration investments. • Case study: 42% hot utility savings potential at a pay-back period of 3.9y.

  9. SICOM: On-site inspection systems

    International Nuclear Information System (INIS)

    Serna, J.J.; Quecedo, M.; Fernandez, J.R.

    2002-01-01

    As the irradiation conditions become more demanding for the fuel than in the past, there is a need for surveillance programs to gather in-reactor operating experience. The data obtained in these programs can be used to assess the performance of current fuel designs and the improvements incorporated to the fuel assembly design, the performance of the advanced cladding alloys, etc. In these regards, valuable data is obtained from on-site fuel inspections. These on-site data comprise fuel assembly dimensional data such as length and distortion (tilt, twist and bow) and fuel rod data such as length and oxide thickness. These data have to be reliable and accurate to be useful thus, demanding a high precision inspection equipment. However, the inspection equipment has to be also robust and flexible enough to operate in the plant spent fuel pool and, sometimes, without interfering in the works carried out during a plant outage. To meet these requirements, during the past years ENUSA and TECNATOM have developed two on-site inspection systems. While the first system can perform most of the typical measurements in a stand-alone manner thus, without interfering with the critical path of the reload, the second one reduces the inspection time but requires using the plant capabilities. The paper describes both equipment for fuel on-site inspection, their characteristics and main features. (author)

  10. Requirements of on-site facilities

    International Nuclear Information System (INIS)

    Burchardt, H.

    1977-01-01

    1) Requirements of on-site facilities: a) brief description of supplying the site with electricity and water; communication facilities, b) necessary facilities for containment and pipeline installation, c) necessary facilities for storage, safety, accommodation of personnel, housing; workshops; 2) Site management: a) Organisation schedules for 'turn-key-jobs' and 'single commission', b) Duties of the supervisory staff. (orig.) [de

  11. Total water, phosphorus relaxation and inter-atomic organic to inorganic interface are new determinants of trabecular bone integrity.

    Directory of Open Access Journals (Sweden)

    Ratan Kumar Rai

    Full Text Available Bone is the living composite biomaterial having unique structural property. Presently, there is a considerable gap in our understanding of bone structure and composition in the native state, particularly with respect to the trabecular bone, which is metabolically more active than cortical bones, and is readily lost in post-menopausal osteoporosis. We used solid-state nuclear magnetic resonance (NMR to compare trabecular bone structure and composition in the native state between normal, bone loss and bone restoration conditions in rat. Trabecular osteopenia was induced by lactation as well as prolonged estrogen deficiency (bilateral ovariectomy, Ovx. Ovx rats with established osteopenia were administered with PTH (parathyroid hormone, trabecular restoration group, and restoration was allowed to become comparable to sham Ovx (control group using bone mineral density (BMD and µCT determinants. We used a technique combining (1H NMR spectroscopy with (31P and (13C to measure various NMR parameters described below. Our results revealed that trabecular bones had diminished total water content, inorganic phosphorus NMR relaxation time (T1 and space between the collagen and inorganic phosphorus in the osteopenic groups compared to control, and these changes were significantly reversed in the bone restoration group. Remarkably, bound water was decreased in both osteopenic and bone restoration groups compared to control. Total water and T1 correlated strongly with trabecular bone density, volume, thickness, connectivity, spacing and resistance to compression. Bound water did not correlate with any of the microarchitectural and compression parameters. We conclude that total water, T1 and atomic space between the crystal and organic surface are altered in the trabecular bones of osteopenic rats, and PTH reverses these parameters. Furthermore, from these data, it appears that total water and T1 could serve as trabecular surrogates of micro-architecture and

  12. Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma rays

    Science.gov (United States)

    Dantas, A. R. V.; Gauthier, M. K.; Coss, J. R.

    1985-01-01

    The total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).

  13. Role of integrated approach of yoga therapy in a failed post-total knee replacement of bilateral knees

    Directory of Open Access Journals (Sweden)

    John Ebnezar

    2014-01-01

    Full Text Available OA Knee is the most common arthritis. Knee replacement Surgeries are being done increasingly in the present times. This has led to the violation of the standard indications and when knees are replaced ignoring other co - musculoskeletal conditions it results in the surgery failing early. This is about a patient who encountered a failed TKR due to improper selection as patient had bilateral OA Hip that was ignored in the initial stages. To overcome the problem she was advised bilateral hip replacement which would leave her with four replacements in the lower limb. She refused surgery and was told there are no alternative treatment options. This patient underwent a 3 week integrated course of IAYT at our center and she made a remarkable recovery. IAYT is a good non-surgical treatment that can be affective both before and after knee replacement and it should be considered as the first choice of treatment before surgery.

  14. Continuous feed, on-site composting of kitchen garbage.

    Science.gov (United States)

    Hwang, Eung-Ju; Shin, Hang-Sik; Tay, Joo-Hwa

    2002-04-01

    Kitchen garbage generated at a school cafeteria was treated and stabilised in a controlled on-site composting unit for volume reduction and on-site utilisation of processed garbage. The on-site composter was fed with the garbage on a daily basis during the two-months experimental period. Compost was not removed from the unit but was entirely reused as a bulking agent in order to minimise the need for additional bulking agent and compost handling. Performance of the composter tinder this condition was investigated. Most of the easily degradable organic matter (EDM) in the garbage was biodegraded rapidly, and the final product had a low content of EDM. Lipids, total sugar, and hemi-cellulose were degraded 96%, 81%, and 66% respectively. Free air space (FAS) was higher than 0.5 all the time, so accumulation of dry matter in the unit was not significant in reducing reaction efficiency. Other reaction parameters such as pH and MC were kept within a suitable range; however, it was advisable to maintain MC at over 46%. As a result, this method of operation was able to stabilise the garbage with low sawdust demand and little compost production.

  15. Economic Impacts of Total Water Use Control in the Heihe River Basin in Northwestern China—An Integrated CGE-BEM Modeling Approach

    Directory of Open Access Journals (Sweden)

    Na Li

    2015-03-01

    Full Text Available This paper develops an integrated modeling approach combined with a top-down dynamic computable general equilibrium (CGE model and a bottom-up bio-economic model (BEM to study the economic impact of a total water use control policy in the Heihe river basin, northwestern China. The integrated CGE-BEM model is regionally disaggregated with a variety of crops and livestock, and includes the responses of farmers and consequent feedback effects in the regional economic system. The results show that under the total water use control scenario, the water use structure is changed and water use efficiency is improved. The total water use control policy has limited negative impact on the regional economic growth with only a slightly lower growth rate of 13.38% compared with a growth rate of 14% by 2020 under a business as usual water use scenario. However, the total water use control policy has significant negative impacts on several sectors, especially agriculture and food processing. It is expected cropping systems will change through a replacement of water-intensive crops with water-efficient crops. Farmers’ incomes will decrease by 3.14%. In order to alleviate farmers’ income loss and deal with water use conflicts across different sectors and regions, the promotion of migration of surplus labor from agriculture to non-agricultural sectors and the improvement of water use efficiency in agriculture are needed.

  16. Integrated batch production and maintenance scheduling for multiple items processed on a deteriorating machine to minimize total production and maintenance costs with due date constraint

    Directory of Open Access Journals (Sweden)

    Zahedi Zahedi

    2016-04-01

    Full Text Available This paper discusses an integrated model of batch production and maintenance scheduling on a deteriorating machine producing multiple items to be delivered at a common due date. The model describes the trade-off between total inventory cost and maintenance cost as the increase of production run length. The production run length is a time bucket between two consecutive preventive maintenance activities. The objective function of the model is to minimize total cost consisting of in process and completed part inventory costs, setup cost, preventive and corrective maintenance costs and rework cost. The problem is to determine the optimal production run length and to schedule the batches obtained from determining the production run length in order to minimize total cost.

  17. Un enfoque basado en ontología para la gestión integrada del medio ambiente y de la seguridad y la salud en obra An ontology-based approach for on-site integrated environmental and health and safety management

    Directory of Open Access Journals (Sweden)

    Marta Gangolells

    2012-12-01

    Full Text Available Este artículo tiene como objetivo favorecer la implementación de sistemas integrados de gestión ambiental, de seguridad y salud en empresas constructoras, centrándose en el subsistema de control de los impactos ambientales y los riesgos de seguridad y salud en obra. La gran compatibilidad que presentan los requerimientos vinculados al control operacional establecidos en la normas ISO 14001:2004 y OHSAS 18001:2007 así como las interacciones existentes entre impactos ambientales y riesgos de seguridad y salud (Gangolells et al., 2009, Gangolells et al., 2010 han motivado el desarrollo de una ontología que permite construir un modelo integrado para el control operacional en obras de construcción. El enfoque desarrollado está fuertemente influenciado por la metodología de Noy y McGuiness (2001 y modela los conceptos clave y las relaciones del campo de forma estructurada, extensibe, flexible, reutilizable y compartible. Este enfoque basado en ontologías ha sido implementado mediante Protégé 3.4 beta y correctamente evaluado utilizando preguntas de competencia, verificaciones internas y entrevistas de validación con expertos. Este artículo desarrolla el primer enfoque que permite representar, compartir, reutilizar y gestionar el conocimiento relacionado con el control operacional integrado en obra de las incidencias medioambientales, de seguridad y salud y sienta las bases para poder superar la mayoría de las barreras que las empresas constructoras deben afrontar durante el proceso de implementación de un sistema de gestión integrada.This paper presents an innovative approach to implementing integrated environmental and health and safety management systems in construction companies. It focuses on the sub-system for operational control of on-site environmental impacts and health and safety risks. The high compatibility between the operational control requirements that are stated in ISO 14001:2004 and OHSAS 18001:2007 and the

  18. Analysis of integrated animal-fish production system under subtropical hill agro ecosystem in India: growth performance of animals, total biomass production and monetary benefit.

    Science.gov (United States)

    Kumaresan, A; Pathak, K A; Bujarbaruah, K M; Vinod, K

    2009-03-01

    The present study assessed the benefits of integration of animals with fish production in optimizing the bio mass production from unit land in subtropical hill agro ecosystem. Hampshire pigs and Khaki Campbell ducks were integrated with composite fish culture. The pig and duck excreta were directly allowed into the pond and no supplementary feed was given to fish during the period of study. The average levels of N, P and K in dried pig and duck manure were 0.9, 0.7 and 0.6 per cent and 1.3, 0.6 and 0.5 per cent, respectively. The average body weight of pig and duck at 11 months age was 90 and 1.74 kg with an average daily weight gain of 333.33 and 6.44 g, respectively. The fish production in pig-fish and duck-fish systems were 2209 and 2964 kg/ha, respectively while the fish productivity in control pond was only 820 kg/ha. The total biomass (animal and fish) production was higher (pfeeding system compared to the traditional system, however the input/output ratio was 1:1.2 and 1:1.55 for commercial and traditional systems, respectively. It was inferred that the total biomass production per unit land was high (pfish were integrated together.

  19. 75 FR 76487 - Haldex Brake Corporation, Commercial Vehicle Systems, Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-08

    ..., Commercial Vehicle Systems, Including On-Site Leased Workers of Johnston Integration Technologies, a... Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974, as amended (``Act''), 19 U.S.C... system components. The company reports that workers leased from Johnston Integration Technologies, a...

  20. Atmospheric Dust in the Upper Colorado River Basin: Integrated Analysis of Digital Imagery, Total Suspended Particulate, and Meteorological Data

    Science.gov (United States)

    Urban, F. E.; Reynolds, R. L.; Neff, J. C.; Fernandez, D. P.; Reheis, M. C.; Goldstein, H.; Grote, E.; Landry, C.

    2012-12-01

    Improved measurement and observation of dust emission and deposition in the American west would advance understanding of (1) landscape conditions that promote or suppress dust emission, (2) dynamics of dryland and montane ecosystems, (3) premature melting of snow cover that provides critical water supplies, and (4) possible effects of dust on human health. Such understanding can be applied to issues of land management, water-resource management, as well as the safety and well-being of urban and rural inhabitants. We have recently expanded the scope of particulate measurement in the Upper Colorado River basin through the establishment of total-suspended-particulate (TSP) measurement stations located in Utah and Colorado with bi-weekly data (filter) collection, along with protocols for characterizing dust-on-snow (DOS) layers in Colorado mountains. A sub-network of high-resolution digital cameras has been co-located with several of the TSP stations, as well as at other strategic locations. These real-time regional dust-event detection cameras are internet-based and collect digital imagery every 6-15 minutes. Measurements of meteorological conditions to support these collections and observations are provided partly by CLIM-MET stations, four of which were deployed in 1998 in the Canyonlands (Utah) region. These stations provide continuous, near real-time records of the complex interaction of wind, precipitation, vegetation, as well as dust emission and deposition, in different land-use settings. The complementary datasets of dust measurement and observation enable tracking of individual regional dust events. As an example, the first DOS event of water year 2012 (Nov 5, 2011), as documented at Senator Beck Basin, near Silverton, Colorado, was also recorded by the camera at Island-in-the-Sky (200 km to the northwest), as well as in aeolian activity and wind data from the Dugout Ranch CLIM-MET station (170 km to the west-northwest). At these sites, strong winds and the

  1. From a single encapsulated detector to the spectrometer for INTEGRAL satellite: predicting the peak-to-total ratio at high gamma-energies

    OpenAIRE

    Kshetri, Ritesh

    2012-01-01

    In two recent papers (R. Kshetri, JINST 2012 7 P04008; ibid., P07006), a probabilistic formalism was introduced to predict the response of encapsulated type composite germanium detectors like the SPI (spectrometer for INTEGRAL satellite). Predictions for the peak-to-total and peak-to-background ratios are given at 1.3 MeV for the addback mode of operation. The application of the formalism to clover germanium detector is discussed in two separate papers (R. Kshetri, JINST 2012 7 P07008; ibid.,...

  2. The electromagnetic α3 contributions to e+e--annihilation into fermions in the electroweak theory. Total cross section σT and integrated asymmetry AFB

    International Nuclear Information System (INIS)

    Bardin, D.Yu.; Bilenky, S.M.; Riemann, T.

    1988-01-01

    Analytic expressions are obtained for the integrated α 3 QED contributions to the total cross section σ T and the forward-backward asymmtery A FB in the process e + e - → f + f - γ. Photons from soft and hard bremsstrahlung are assumed not to be observed. The calculations are performed in the ultrarelativistic approximation in fermion masses, m f 2 Z 2 , M Z I Z , but the mass M Z and width Γ Z of the neutral weak gauge boson Z are treated without any further approximations

  3. Nondestructive measurement of total volatile basic nitrogen (TVB-N) in pork meat by integrating near infrared spectroscopy, computer vision and electronic nose techniques.

    Science.gov (United States)

    Huang, Lin; Zhao, Jiewen; Chen, Quansheng; Zhang, Yanhua

    2014-02-15

    Total volatile basic nitrogen (TVB-N) content is an important reference index for evaluating pork freshness. This paper attempted to measure TVB-N content in pork meat using integrating near infrared spectroscopy (NIRS), computer vision (CV), and electronic nose (E-nose) techniques. In the experiment, 90 pork samples with different freshness were collected for data acquisition by three different techniques, respectively. Then, the individual characteristic variables were extracted from each sensor. Next, principal component analysis (PCA) was used to achieve data fusion based on these characteristic variables from 3 different sensors data. Back-propagation artificial neural network (BP-ANN) was used to construct the model for TVB-N content prediction, and the top principal components (PCs) were extracted as the input of model. The result of the model was achieved as follows: the root mean square error of prediction (RMSEP) = 2.73 mg/100g and the determination coefficient (R(p)(2)) = 0.9527 in the prediction set. Compared with single technique, integrating three techniques, in this paper, has its own superiority. This work demonstrates that it has the potential in nondestructive detection of TVB-N content in pork meat using integrating NIRS, CV and E-nose, and data fusion from multi-technique could significantly improve TVB-N prediction performance. Copyright © 2013. Published by Elsevier Ltd.

  4. Utilizing the fluidized bed to initiate water treatment on site

    International Nuclear Information System (INIS)

    Ahmadvand, H.; Germann, G.; Gandee, J.P.; Buehler, V.T.

    1995-01-01

    Escalating wastewater disposal costs coupled with enforcement of stricter regulations push industrial sites previously without water treatment to treat on site. These sites, inexperienced in water treatment, require a treatment technology that is easily installed, operated, and maintained. The aerobic granular activated carbon (GAC) fluidized bed incorporates biological and adsorptive technologies into a simple, cost-effective process capable of meeting strict effluent requirements. Two case studies at industrial sites illustrate the installation and operation of the fluidized bed and emphasize the ability to use the fluidized bed singularly or as an integral component of a treatment system capable of achieving treatment levels that allow surface discharge and reinjection. Attention is focused on BTEX (benzene, toluene, ethylbenzene, and xylenes)

  5. Innovative on-site treatment cuts frac flowback water costs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-11-15

    Water is an essential component of the drilling and hydraulic fracturing or fracking process and so the natural gas industry is a heavy user of water. Learning from other industries, gas producers are now employing mobile service providers with the latest integrated treatment systems (ITS) to clean flowback and produced water from fracturing operations at the wellhead. This paper presents a novel on-site treatment for frac water. ITS are pre-fabricated on moveable skids or a truck trailer with all the necessary controls, piping, valves, instrumentation, pumps, mixers and chemical injection modules. They remove oil and other hydrocarbons, suspended solids, and dissolved metals from the frac water using the tightly controlled chemistry, separation and filtration technology. This method can cut the average cost of treating produced water by 50%, simultaneously allowing drillers to maximize their efforts and manpower on generating oil and gas profits, rather than on water treatment.

  6. From a single encapsulated detector to the spectrometer for INTEGRAL satellite: predicting the peak-to-total ratio at high γ-energies

    International Nuclear Information System (INIS)

    Kshetri, R

    2012-01-01

    In two recent papers (R. Kshetri, JINST 2012 7 P04008; ibid., P07006), a probabilistic formalism was introduced to predict the response of encapsulated type composite germanium detectors like the SPI (spectrometer for INTEGRAL satellite). Predictions for the peak-to-total and peak-to-background ratios are given at 1.3 MeV for the addback mode of operation. The application of the formalism to clover germanium detector is discussed in two separate papers (R. Kshetri, JINST 2012 7 P07008; ibid., P08015). Using the basic approach developed in those papers, for the first time we present a procedure for calculating the peak-to-total ratio of the cluster detector for γ-energies up to 8 MeV. Results are shown for both bare and suppressed detectors as well as for the single crystal and addback modes of operation. We have considered the experimental data of (i) peak-to-total ratio at 1.3 MeV, and (ii) single detector efficiency and addback factor for other energies up to 8 MeV. Using this data, an approximate method of calculating the peak-to-total ratio of other composite detectors, is shown. Experimental validation of our approach (for energies up to 8 MeV) has been confirmed considering the data of the SPI spectrometer. We have discussed about comparisons between various modes of operation and suppression cases. The present paper is the fifth in the series of papers on composite germanium detectors and for the first time discusses about the change in fold distribution and peak-to-total ratio for sophisticated detectors consisting of several modules of miniball, cluster and SPI detectors. Our work could provide a guidance in designing new composite detectors and in performing experimental studies with the existing detectors for high energy gamma-rays.

  7. From a single encapsulated detector to the spectrometer for INTEGRAL satellite: predicting the peak-to-total ratio at high γ-energies

    Science.gov (United States)

    Kshetri, R.

    2012-12-01

    In two recent papers (R. Kshetri, JINST 2012 7 P04008; ibid., P07006), a probabilistic formalism was introduced to predict the response of encapsulated type composite germanium detectors like the SPI (spectrometer for INTEGRAL satellite). Predictions for the peak-to-total and peak-to-background ratios are given at 1.3 MeV for the addback mode of operation. The application of the formalism to clover germanium detector is discussed in two separate papers (R. Kshetri, JINST 2012 7 P07008; ibid., P08015). Using the basic approach developed in those papers, for the first time we present a procedure for calculating the peak-to-total ratio of the cluster detector for γ-energies up to 8 MeV. Results are shown for both bare and suppressed detectors as well as for the single crystal and addback modes of operation. We have considered the experimental data of (i) peak-to-total ratio at 1.3 MeV, and (ii) single detector efficiency and addback factor for other energies up to 8 MeV. Using this data, an approximate method of calculating the peak-to-total ratio of other composite detectors, is shown. Experimental validation of our approach (for energies up to 8 MeV) has been confirmed considering the data of the SPI spectrometer. We have discussed about comparisons between various modes of operation and suppression cases. The present paper is the fifth in the series of papers on composite germanium detectors and for the first time discusses about the change in fold distribution and peak-to-total ratio for sophisticated detectors consisting of several modules of miniball, cluster and SPI detectors. Our work could provide a guidance in designing new composite detectors and in performing experimental studies with the existing detectors for high energy gamma-rays.

  8. Integration

    DEFF Research Database (Denmark)

    Emerek, Ruth

    2004-01-01

    Bidraget diskuterer de forskellige intergrationsopfattelse i Danmark - og hvad der kan forstås ved vellykket integration......Bidraget diskuterer de forskellige intergrationsopfattelse i Danmark - og hvad der kan forstås ved vellykket integration...

  9. On site DNA barcoding by nanopore sequencing.

    Directory of Open Access Journals (Sweden)

    Michele Menegon

    Full Text Available Biodiversity research is becoming increasingly dependent on genomics, which allows the unprecedented digitization and understanding of the planet's biological heritage. The use of genetic markers i.e. DNA barcoding, has proved to be a powerful tool in species identification. However, full exploitation of this approach is hampered by the high sequencing costs and the absence of equipped facilities in biodiversity-rich countries. In the present work, we developed a portable sequencing laboratory based on the portable DNA sequencer from Oxford Nanopore Technologies, the MinION. Complementary laboratory equipment and reagents were selected to be used in remote and tough environmental conditions. The performance of the MinION sequencer and the portable laboratory was tested for DNA barcoding in a mimicking tropical environment, as well as in a remote rainforest of Tanzania lacking electricity. Despite the relatively high sequencing error-rate of the MinION, the development of a suitable pipeline for data analysis allowed the accurate identification of different species of vertebrates including amphibians, reptiles and mammals. In situ sequencing of a wild frog allowed us to rapidly identify the species captured, thus confirming that effective DNA barcoding in the field is possible. These results open new perspectives for real-time-on-site DNA sequencing thus potentially increasing opportunities for the understanding of biodiversity in areas lacking conventional laboratory facilities.

  10. Postulated accident scenarios for the on-site transport of spent nuclear fuel

    International Nuclear Information System (INIS)

    Morandin, G.; Sauve, R.

    2004-01-01

    Once a spent fuel container is loaded with spent fuel it typically travels on-site to a processing building for permanent lid attachment. During on-site transport a lid clamp is utilized to ensure the container lid remains in place. The safe on-site transport of spent nuclear fuel must rely on the structural integrity of the transport container and system of transport. Regard for on-site traffic and safe, efficient travel routes are important and manageable with well thought-out planning. Non-manageable incidences, such as flying debris from tornado force winds or postulated blasts in proximity to the transport container, that may result in high velocity impact and shock loading on the transport system must be considered. This paper consists of simulations that consider these types of postulated accident scenarios using detailed nonlinear finite element techniques

  11. Electron collisions with phenol: Total, integral, differential, and momentum transfer cross sections and the role of multichannel coupling effects on the elastic channel

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Romarly F. da [Instituto de Física “Gleb Wataghin,” Universidade Estadual de Campinas, 13083-859 Campinas, São Paulo (Brazil); Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, 09210-580 Santo André, São Paulo (Brazil); Oliveira, Eliane M. de; Lima, Marco A. P. [Instituto de Física “Gleb Wataghin,” Universidade Estadual de Campinas, 13083-859 Campinas, São Paulo (Brazil); Bettega, Márcio H. F. [Departamento de Física, Universidade Federal do Paraná, CP 19044, 81531-990 Curitiba, Paraná (Brazil); Varella, Márcio T. do N. [Instituto de Física, Universidade de São Paulo, CP 66318, 05315-970 São Paulo, São Paulo (Brazil); Jones, Darryl B. [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide SA 5001 (Australia); Brunger, Michael J. [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide SA 5001 (Australia); Institute of Mathematical Sciences, University of Malaya, 50603 Kuala Lumpur (Malaysia); Blanco, Francisco [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, Ciudad Universitaria, 2840 Madrid (Spain); Colmenares, Rafael [Hospital Ramón y Cajal, 28034 Madrid (Spain); and others

    2015-03-14

    We report theoretical and experimental total cross sections for electron scattering by phenol (C{sub 6}H{sub 5}OH). The experimental data were obtained with an apparatus based in Madrid and the calculated cross sections with two different methodologies, the independent atom method with screening corrected additivity rule (IAM-SCAR), and the Schwinger multichannel method with pseudopotentials (SMCPP). The SMCPP method in the N{sub open}-channel coupling scheme, at the static-exchange-plus-polarization approximation, is employed to calculate the scattering amplitudes at impact energies ranging from 5.0 eV to 50 eV. We discuss the multichannel coupling effects in the calculated cross sections, in particular how the number of excited states included in the open-channel space impacts upon the convergence of the elastic cross sections at higher collision energies. The IAM-SCAR approach was also used to obtain the elastic differential cross sections (DCSs) and for correcting the experimental total cross sections for the so-called forward angle scattering effect. We found a very good agreement between our SMCPP theoretical differential, integral, and momentum transfer cross sections and experimental data for benzene (a molecule differing from phenol by replacing a hydrogen atom in benzene with a hydroxyl group). Although some discrepancies were found for lower energies, the agreement between the SMCPP data and the DCSs obtained with the IAM-SCAR method improves, as expected, as the impact energy increases. We also have a good agreement among the present SMCPP calculated total cross section (which includes elastic, 32 inelastic electronic excitation processes and ionization contributions, the latter estimated with the binary-encounter-Bethe model), the IAM-SCAR total cross section, and the experimental data when the latter is corrected for the forward angle scattering effect [Fuss et al., Phys. Rev. A 88, 042702 (2013)].

  12. DBE on site public relations tasks

    International Nuclear Information System (INIS)

    Krug, H.J.; Meyer, R.

    1998-01-01

    Full text: Thesis: There is no 'golden rule' for an immediate increase in acceptance of nuclear facility sites - this applies to nuclear power plants as well as waste management facilities. The German Company for the Construction and Operation of Repositories for Waste Products (DBE - entrusted on behalf of the Federal Government with the management of all three German waste repository sites (projects), Morsleben, Konrad, Gorleben - concentrates in the field of public relations work on the following: - caring for (and informing) visitors from home and abroad; - cooperation with local and regional authorities and their representatives, press, media, etc. including associate editing of the GORLEBEN-information leaflet which appears monthly or every second month in cooperation with the Federal Board for Radiation Protection (BfS), as well as press releases if required; - responding to inquiries and visit requests of press, radio and TV. Basic work: - early and comprehensive information of the public at the sites about progress of work and possible exceptional events with special involvement of local politicians and representatives as well as press agencies. Close contacts exist to the local paper and to a national paper; - municipal representatives and the media are regularly directly informed on site or sporadically at their own request; - special emphasis is placed on the spoken, explaining word, namely that communication and discussion are valued more highly than written material. Of course, transparencies, films and brochures are available to support the spoken word; - continual availability for discussion and information presentations e.g., also at weekends; - maintenance of casual contacts to opponents of the plant. In Gorleben - the site of further waste management facilities beside the exploration mine - there is close cooperation with representatives of the other important companies and institutions hence, visitors are generally pooled, i.e., the majority

  13. On-site monitoring of plutonium workers

    International Nuclear Information System (INIS)

    Burns, P.A.; Richardson, C.K.; Paulka, S.

    1996-01-01

    Full text: As part of the Maralinga rehabilitation program it is necessary to implement a system of on-site monitoring for the workers in order to ensure that they do not exceed recommended dose limits. The main problem in the rehabilitation work is the inhalation of dusts which contain micron sized plutonium particles. Using the new ICRP lung model and available data derived from measurements on contaminated soils, the intake for a dose of 20 mSv was calculated to be 1200 Bq. Four methods are available for direct measurements on workers; nasal swabs, faecal analysis, urine analysis and lung monitoring. The first two techniques are sensitive but will give varying results depending of the time interval between exposure and sampling. They are also difficult to implement on a routine basis. For the second two techniques, the activity in the lungs and the activity excreted per day in the urine remain relatively constant for several years following an intake, making more accurate dose estimates possible. The ICRP lung model predicts deposition in the lung of the order of 5% of intake and urinary excretion models predict approximately 10 -5 of this will be excreted daily in the urine. Lung monitoring of workers will be performed routinely at Maralinga in a partly enclosed room constructed from 10cm of steel, using two 50 mm diameter germanium detectors shielded with lead collimators. The detectors will measure 241 Am, which has grown in following the decay of 241 Pu, and the minimum detectable activity will be 15 - 20 Bq depending on the chest thickness and chest wall thickness of the individual being measured. Urine will be collected routinely and selected samples will be measured. The minimum detectable activity will be 2001μBq of 239 Pu in a daily urine sample

  14. [Integrity].

    Science.gov (United States)

    Gómez Rodríguez, Rafael Ángel

    2014-01-01

    To say that someone possesses integrity is to claim that that person is almost predictable about responses to specific situations, that he or she can prudentially judge and to act correctly. There is a closed interrelationship between integrity and autonomy, and the autonomy rests on the deeper moral claim of all humans to integrity of the person. Integrity has two senses of significance for medical ethic: one sense refers to the integrity of the person in the bodily, psychosocial and intellectual elements; and in the second sense, the integrity is the virtue. Another facet of integrity of the person is la integrity of values we cherish and espouse. The physician must be a person of integrity if the integrity of the patient is to be safeguarded. The autonomy has reduced the violations in the past, but the character and virtues of the physician are the ultimate safeguard of autonomy of patient. A field very important in medicine is the scientific research. It is the character of the investigator that determines the moral quality of research. The problem arises when legitimate self-interests are replaced by selfish, particularly when human subjects are involved. The final safeguard of moral quality of research is the character and conscience of the investigator. Teaching must be relevant in the scientific field, but the most effective way to teach virtue ethics is through the example of the a respected scientist.

  15. Liability for on-site nuclear property damage

    International Nuclear Information System (INIS)

    Neems, H.J.

    2000-01-01

    Typically, liability for on-site property addressed in contracts between operator and its suppliers. Nuclear power plant operators ordinarily protect themselves against risk of nuclear damage to on-site property by insurance. Nuclear liability laws do not specifically address liability for nuclear damage to on-site property. Nuclear plant owners should address risk of damage to on-site property when developing risk management program

  16. Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index.

    Science.gov (United States)

    Nalewajko-Sieliwoniuk, Edyta; Iwanowicz, Magdalena; Kalinowski, Sławomir; Kojło, Anatol

    2016-03-10

    In this work, we present a novel chemiluminescence (CL) method based on direct-injection detector (DID) integrated with the multi-pumping flow system (MPFS) to chemiluminescence determination of the total polyphenol index. In this flow system, the sample and the reagents are injected directly into the cone-shaped detection cell placed in front of the photomultiplier window. Such construction of the detection chamber allows for fast measurement of the CL signal in stopped-flow conditions immediately after mixing the reagents. The proposed DID-CL-MPFS method is based on the chemiluminescence of nanocolloidal manganese(IV)-hexametaphosphate-ethanol system. The application of ethanol as a sensitizer, eliminated the use of carcinogenic formaldehyde. Under the optimized experimental conditions, the chemiluminescence intensities are proportional to the concentration of gallic acid in the range from 5 to 350 ng mL(-1). The DID-CL-MPFS method offers a number of advantages, including low limit of detection (0.80 ng mL(-1)), high precision (RSD = 3.3%) and high sample throughput (144 samples h(-1)) as well as low consumption of reagents, energy and low waste generation. The proposed method has been successfully applied to determine the total polyphenol index (expressed as gallic acid equivalent) in a variety of plant-derived food samples (wine, tea, coffee, fruit and vegetable juices, herbs, spices). Copyright © 2016 Elsevier B.V. All rights reserved.

  17. On-site and off-site emergency planning at Cekmece Nuclear Research and Training Centre

    International Nuclear Information System (INIS)

    Soyberk, O.A.

    1986-01-01

    An emergency plan was prepared for minimizing the consequences of any unforeseen radiation accident in Cekmece Nuclear Research and Training Centre (CNAEM) in Istanbul, Turkey. CNAEM is situated near Kucukcekmece Lake, which is about 30 km to the west of Istanbul. It includes two pool-type research reactors of 1 MW(th) and 5 MW(th). The population in the nearest inhabited areas varies from 1000 to 50,000. Accidents are classified, according to their severity, into three categories at CNAEM: (a) local emergency, (b) on-site emergency, (c) off-site emergency. During local emergency situations evacuation is not necessary. An on-site emergency situation requires the evacuation of personnel from the plant. Personnel hearing the emergency alarm should move directly to the preselected place as soon as possible. An off-site emergency is any accident that leads to widespread contamination outside the boundary. In this situation the Turkish Atomic Energy Authority and governmental authorities are notified immediately. The emergency organization group consists of: (a) Plant Superintendent, (b) Emergency Director, (c) Reactor Supervisor, (d) Senior Health Physicist, (e) Reactor Shift Operator, (f) Health Physicists. The administration building will be used as the Emergency Control Centre. The emergency teams working under the direction of the Emergency Director consist of: (a) Health Physics, (b) Fire and Rescue, (c) First Aid and Decontamination, (d) Transportation, (e) Security and Patrol. The emergency situation is evaluated in three phases at CNAEM. The first phase is the first few hours after the beginning of the accident. The second phase is between 8-10 hours or more following the first phase. The third phase is the recovery phase. The integrated doses over periods of two hours and two days are calculated according to the situation of the core, i.e. total or partial melting, and weather conditions. The results of the calculated parameters can be adapted to possible

  18. ON-SITE SOLID PHRASE EXTRACTION AND LABORATORY ...

    Science.gov (United States)

    Fragrance materials, such as synthetic musks in aqueous samples, are normally analyzed by GC/MS in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. A I -L sample, however, usually provides too little analyte for full-scan data acquisition. An on-site extraction method for extracting synthetic musks from 60 L of wastewater effluent has been developed. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for various synthetic musk compounds. Quantification of these compounds was conveniently achieved from the full-scan data directly, without preparing SIM descriptors for each compound to acquire SIM data. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Quality. Located In the subtasks are the various research projects being performed in support of this Task and more in-depth coverage of each project. Briefly, each project's objective is stated below.Subtask 1: To integrate state-of-the-art technologies (polar organic chemical integrative samplers, advanced solid-phase extraction methodologies with liquid chromatography/electrospray/mass spectrometry) and apply them to studying the sources and fate of a select list of PPCPs. Application and improvement of analytical methodologies that can detect non-volatile, polar, water-sol

  19. 75 FR 66795 - TTM Technologies, Including On-Site Leased Workers From Kelly Services, Aerotek, and an On-Site...

    Science.gov (United States)

    2010-10-29

    ... follows: ``All workers TTM Technologies, including on-site leased workers from Kelly Services and Aerotek... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-64,993] TTM Technologies, Including On-Site Leased Workers From Kelly Services, Aerotek, and an On-Site Leased Worker From Orbotech...

  20. Greenhouse gas emissions from on-site wastewater treatment systems

    Science.gov (United States)

    Somlai-Haase, Celia; Knappe, Jan; Gill, Laurence

    2016-04-01

    Nearly one third of the Irish population relies on decentralized domestic wastewater treatment systems which involve the discharge of effluent into the soil via a percolation area (drain field). In such systems, wastewater from single households is initially treated on-site either by a septic tank and an additional packaged secondary treatment unit, in which the influent organic matter is converted into carbon dioxide (CO2) and methane (CH4) by microbial mediated processes. The effluent from the tanks is released into the soil for further treatment in the unsaturated zone where additional CO2 and CH4 are emitted to the atmosphere as well as nitrous oxide (N2O) from the partial denitrification of nitrate. Hence, considering the large number of on-site systems in Ireland and internationally, these are potential significant sources of greenhouse gas (GHG) emissions, and yet have received almost no direct field measurement. Here we present the first attempt to quantify and qualify the production and emissions of GHGs from a septic tank system serving a single house in the County Westmeath, Ireland. We have sampled the water for dissolved CO2, CH4 and N2O and measured the gas flux from the water surface in the septic tank. We have also carried out long-term flux measurements of CO2 from the drain field, using an automated soil gas flux system (LI-8100A, Li-Cor®) covering a whole year semi-continuously. This has enabled the CO2 emissions from the unsaturated zone to be correlated against different meteorological parameters over an annual cycle. In addition, we have integrated an ultraportable GHG analyser (UGGA, Los Gatos Research Inc.) into the automated soil gas flux system to measure CH4 flux. Further, manual sampling has also provided a better understanding of N2O emissions from the septic tank system.

  1. 75 FR 55613 - Dupont Teijin Films Including On-Site Leased Workers From Schenkers Logistics, Inc., Florence, SC...

    Science.gov (United States)

    2010-09-13

    ... Including On-Site Leased Workers From Schenkers Logistics, Inc., Florence, SC; Amended Certification... Teijin Films, including on-site leased workers from Schenkers Logistics, Inc., Florence, South Carolina... leased workers of Schenkers Logistics, Inc., Florence, South Carolina, who became totally or partially...

  2. 76 FR 62452 - Avon Products, Inc. Including On-Site Leased Workers From Spherion/Source Right, Springdale, OH...

    Science.gov (United States)

    2011-10-07

    .... Including On-Site Leased Workers From Spherion/Source Right, Springdale, OH; Amended Certification Regarding... workers of the subject firm. The company reports that workers leased from Spherion/Source Right were...., including on-site leased workers from Spherion/Source Right, Springdale, Ohio, who became totally or...

  3. 76 FR 62451 - Avon Products, Inc., Including On-Site Leased Workers From Spherion/Source Right, Springdale...

    Science.gov (United States)

    2011-10-07

    ...., Including On-Site Leased Workers From Spherion/Source Right, Springdale, Ohio; Amended Certification... workers of the subject firm. The company reports that workers leased from Spherion/Source Right were...., including on-site leased workers from Spherion/Source Right, Springdale, Ohio, who became totally or...

  4. EPICO 4.0. 'Total quality' in the management of invasive candidiasis in critically ill patients by analysing the integrated process.

    Science.gov (United States)

    Zaragoza, Rafael; Ferrer, Ricard; Llinares, Pedro; Maseda, Emilio; Rodríguez, Alejandro; Grau, Santiago; Quindós, Guillermo

    A high quality integrated process in the clinical setting of non-neutropenic critically ill patients at risk for invasive candidiasis is a necessary tool to improve the management of these patients. To identify the key points on invasive candidiasis in order to develop a set of recommendations with a high level of consensus required for the creation of a total quality integrated process for the management of non-neutropenic critically ill patients at risk of invasive candidiasis. After a thorough review of the literature of the previous five years, a Spanish prospective questionnaire, which measured consensus by the Delphi technique, was anonymously conducted by e-mail, including 31 national multidisciplinary experts with extensive experience in invasive fungal infections, from six national scientific societies. The experts included a specialist in intensive care medicine, anesthetists, microbiologists, pharmacologists, and specialists in infectious diseases that responded 27 questions prepared by the coordination group. The educational objectives considered six processes that included knowledge of the local epidemiology, the creation and development of multidisciplinary teams, the definitions of the process, protocols, and indicators (KPI), an educational phase, hospital implementation, and the measurement of outcomes. The level of agreement among experts in each category to be selected should exceed 70%. In a second phase, after drawing up the recommendations of the selected processes, a face to face meeting with more than 60 specialists was held. The specialists were asked to validate the pre-selected recommendations. Firstly, 20 recommendations from all the sections were pre-selected: Knowledge of local epidemiology (3 recommendations), creation and development of multidisciplinary teams (3), definition of the process, protocols and indicators (1), educational phase (3), hospital implementation (3), and measurement of outcomes (7). After the second phase, 18

  5. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  6. Prediction of total organic carbon content in shale reservoir based on a new integrated hybrid neural network and conventional well logging curves

    Science.gov (United States)

    Zhu, Linqi; Zhang, Chong; Zhang, Chaomo; Wei, Yang; Zhou, Xueqing; Cheng, Yuan; Huang, Yuyang; Zhang, Le

    2018-06-01

    There is increasing interest in shale gas reservoirs due to their abundant reserves. As a key evaluation criterion, the total organic carbon content (TOC) of the reservoirs can reflect its hydrocarbon generation potential. The existing TOC calculation model is not very accurate and there is still the possibility for improvement. In this paper, an integrated hybrid neural network (IHNN) model is proposed for predicting the TOC. This is based on the fact that the TOC information on the low TOC reservoir, where the TOC is easy to evaluate, comes from a prediction problem, which is the inherent problem of the existing algorithm. By comparing the prediction models established in 132 rock samples in the shale gas reservoir within the Jiaoshiba area, it can be seen that the accuracy of the proposed IHNN model is much higher than that of the other prediction models. The mean square error of the samples, which were not joined to the established models, was reduced from 0.586 to 0.442. The results show that TOC prediction is easier after logging prediction has been improved. Furthermore, this paper puts forward the next research direction of the prediction model. The IHNN algorithm can help evaluate the TOC of a shale gas reservoir.

  7. First series of total robotic hysterectomy (TRH) using new integrated table motion for the da Vinci Xi: feasibility, safety and efficacy.

    Science.gov (United States)

    Giannini, Andrea; Russo, Eleonora; Mannella, Paolo; Palla, Giulia; Pisaneschi, Silvia; Cecchi, Elena; Maremmani, Michele; Morelli, Luca; Perutelli, Alessandra; Cela, Vito; Melfi, Franca; Simoncini, Tommaso

    2017-08-01

    To present the first case series of total robotic hysterectomy (TRH), using integrated table motion (ITM), which is a new feature comprising a unique operating table by Trumpf Medical that communicates wirelessly with the da Vinci Xi surgical system. ITM has been specifically developed to improve multiquadrant robotic surgery such as that conducted in colorectal surgery. Between May and October 2015, a prospective post-market study was conducted on ITM in the EU in 40 cases from different specialties. The gynecological study group comprised 12 patients. Primary endpoints were ITM feasibility, safety and efficacy. Ten patients underwent TRH. Mean number of ITM moves was three during TRH; there were 31 instances of table moves in the ten procedures. Twenty-eight of 31 ITM moves were made to gain internal exposure. The endoscope remained inserted during 29 of the 31 table movements (94%), while the instruments remained inserted during 27 of the 31 moves (87%). No external instrument collisions or other problems related to the operating table were noted. There were no ITM safety-related observations and no adverse events. This preliminary study demonstrated the feasibility, safety and efficacy of ITM for the da Vinci Xi surgical system in TRH. ITM was safe, with no adverse events related to its use. Further studies will be useful to define the real role and potential benefit of ITM in gynecological surgery.

  8. First Zenith Total Delay and Integrated Water Vapour Estimates from the Near Real-Time GNSS Data Processing Systems at the University of Luxembourg

    Science.gov (United States)

    Ahmed, F.; Teferle, F. N.; Bingley, R. M.

    2012-04-01

    Since September 2011 the University of Luxembourg in collaboration with the University of Nottingham has been setting up two near real-time processing systems for ground-based GNSS data for the provision of zenith total delay (ZTD) and integrated water vapour (IWV) estimates. Both systems are based on Bernese v5.0, use the double-differenced network processing strategy and operate with a 1-hour (NRT1h) and 15-minutes (NRT15m) update cycle. Furthermore, the systems follow the approach of the E-GVAP METO and IES2 systems in that the normal equations for the latest data are combined with those from the previous four updates during the estimation of the ZTDs. NRT1h currently takes the hourly data from over 130 GNSS stations in Europe whereas NRT15m is primarily using the real-time streams of EUREF-IP. Both networks include additional GNSS stations in Luxembourg, Belgium and France. The a priori station coordinates for all of these stem from a moving average computed over the last 20 to 50 days and are based on the precise point positioning processing strategy. In this study we present the first ZTD and IWV estimates obtained from the NRT1h and NRT15m systems in development at the University of Luxembourg. In a preliminary evaluation we compare their performance to the IES2 system at the University of Nottingham and find the IWV estimates to agree at the sub-millimetre level.

  9. Spent-fuel storage - MRS and/or on-site?

    International Nuclear Information System (INIS)

    Fuierer, A.A.

    1991-01-01

    The US government through the Office of Civilian Radioactive Waste Management (OCRWM) is seeking by the use of an authorized negotiator a site for a monitored retrievable storage (MRS) facility. Based on a public information document provided by the office of the negotiator, the MRS will be an integral part of the federal system for safe and permanent disposal of the nation's high-level radioactive wastes. It is planned that the MRS will accept and store spent fuel above ground until a repository opens and spent fuel that has been stored is shipped from the MRS to the repository. Additional spent fuel stored at reactor sites will be shipped to the MRS, which will be used as a staging area to assemble dedicated trains for shipment to the repository. The intent of the MRS is to reduce utilities' needs to expand on-site storage of spent fuel. A utility viewpoint may emphasize an alternate set of priorities. The waste management system must be considered as an overall system involving both the utility and DOE that begins with the first discharge of spent nuclear fuel from a commercial reactor and ends with high-level waste in a final repository. Many studies have been made on individual components of a waste system. This study, with the benefit of past hands-on experience as a guide, looks at costs and reliability for a total system concept with particular emphasis on the interface between the utility and Department of Energy

  10. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of

  11. On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System Development

    Energy Technology Data Exchange (ETDEWEB)

    Caffrey, Gus J. [Idaho National Laboratory, Idaho Falls, ID (United States); Egger, Ann E. [Idaho National Laboratory, Idaho Falls, ID (United States); Krebs, Kenneth M. [Idaho National Laboratory, Idaho Falls, ID (United States); Milbrath, B. D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jordan, D. V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Warren, G. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wilmer, N. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-01

    We have designed and tested hardware and software for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—Osiris—software filters the spectral data to display only radioisotopic information relevant to CTBT on-site inspections, e.g.,132I. A set of over 100 fission-product spectra was employed for Osiris testing. These spectra were measured, where possible, or generated by modeling. The synthetic test spectral compositions include non-nuclear-explosion scenarios, e.g., a severe nuclear reactor accident, and nuclear-explosion scenarios such as a vented underground nuclear test. Comparing its computer-based analyses to expert visual analyses of the test spectra, Osiris correctly identifies CTBT-relevant fission product isotopes at the 95% level or better.The Osiris gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC Transpec-100, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer was used successfully during the recent 2014 CTBT Integrated Field Exercise in Jordan. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. To date, software development has been the main focus of the Osiris project. In FY2016-17, we plan to modify the Osiris hardware, integrate the Osiris software and hardware, and conduct rigorous field tests to ensure that the Osiris system will function correctly during CTBT on-site inspections. The planned development will raise Osiris to technology readiness level TRL-8; transfer the Osiris technology to a commercial manufacturer, and demonstrate Osiris to potential CTBT on-site inspectors.

  12. On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System Development

    International Nuclear Information System (INIS)

    Caffrey, Gus J.; Egger, Ann E.; Krebs, Kenneth M.; Milbrath, B. D.; Jordan, D. V.; Warren, G. A.; Wilmer, N. G.

    2015-01-01

    We have designed and tested hardware and software for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy-Osiris-software filters the spectral data to display only radioisotopic information relevant to CTBT on-site inspections, e.g.,132I. A set of over 100 fission-product spectra was employed for Osiris testing. These spectra were measured, where possible, or generated by modeling. The synthetic test spectral compositions include non-nuclear-explosion scenarios, e.g., a severe nuclear reactor accident, and nuclear-explosion scenarios such as a vented underground nuclear test. Comparing its computer-based analyses to expert visual analyses of the test spectra, Osiris correctly identifies CTBT-relevant fission product isotopes at the 95% level or better.The Osiris gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC Transpec-100, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer was used successfully during the recent 2014 CTBT Integrated Field Exercise in Jordan. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. To date, software development has been the main focus of the Osiris project. In FY2016-17, we plan to modify the Osiris hardware, integrate the Osiris software and hardware, and conduct rigorous field tests to ensure that the Osiris system will function correctly during CTBT on-site inspections. The planned development will raise Osiris to technology readiness level TRL-8; transfer the Osiris technology to a commercial manufacturer, and demonstrate Osiris to potential CTBT on-site inspectors.

  13. 7 CFR 205.403 - On-site inspections.

    Science.gov (United States)

    2010-01-01

    ..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) ORGANIC FOODS PRODUCTION ACT PROVISIONS NATIONAL ORGANIC PROGRAM Certification § 205.403 On-site inspections. (a) On-site inspections. (1... site that produces or handles organic products and that is included in an operation for which...

  14. On-site and off-site activities

    International Nuclear Information System (INIS)

    Martin, H.D.

    1986-01-01

    Design principles for NPP training programs. Effects of NPP contracts. Effects of domestic industrial activities. The role of international bodies. Requirements for on-site training. Training abroad, technical, financial and social aspects. Training center on-site, an evaluation. (orig.)

  15. Innovative on-site approach to oil based drilling mud waste management

    International Nuclear Information System (INIS)

    Laurell, A.

    1999-01-01

    An innovative system has been developed by Unique Oilfield Technology Services (UNOTEC) for the environmentally safe containment and decomposition of oily drilling residuals. The approach is a complete management system which provides an on-site alternative to off-site disposal. The approach uses the principles of total containment and microbial decomposition of hydrocarbons. The complete management system transforms the waste into an end product suitable for on-site land treatment, in accordance with regulatory guidelines. This paper describes how the approach can eliminate the future environmental risk and economic liability associated with hydrocarbon contaminated materials

  16. REPORT OF ON-SITE INSPECTION WORKSHOP-16

    Energy Technology Data Exchange (ETDEWEB)

    Sweeney, J J

    2009-07-07

    The central issue addressed by this workshop was the task of making the on-site inspection (OSI) part of the Comprehensive Nuclear-Test-Ban Treaty verification system operationally ready at entry into force of the Treaty. It is recognized, and this was emphasized by the 2008 OSI Integrated Field Exercise (IFE), that it is not possible to develop every part of the OSI regime simultaneously. Therefore, it is necessary to prioritize the approach to OSI readiness. The reviews of the IFE have pointed to many elements of OSI readiness that still need development. The objective of this workshop was to provide priorities for the path forward for Working Group B to consider. Several critical areas have been identified that are related to the development of OSI readiness: (1) Technology development: Priorities are radionuclide and noble gas sampling and analysis, visual observation, multispectral/infrared imaging methods, active seismic methods and the recognition of the importance of signatures. (2) Organizational development: Priorities are health and safety, the Operations Support Centre, the Equipment Storage and Maintenance Facility, information technology data flow and communications. (3) Resources: The expertise to develop key parts of the OSI regime is not available within the current OSI Division staff. To develop these aspects of the regime will require more staff or supplements to the staff with cost-free experts or other means. Aspects of the system that could benefit from more staff include radionuclide and noble gas detection methods, data flow and communications, visual observation, multispectral/infrared methods and health and safety. As the path forward, participants of this workshop recognized a need to optimize the development of OSI priorities. The outcome of this workshop is to suggest for consideration an operational approach to OSI readiness that utilizes results of an evaluation of the relative effectiveness of OSI elements versus their relative

  17. Heat recovery subsystem and overall system integration of fuel cell on-site integrated energy systems

    Science.gov (United States)

    Mougin, L. J.

    1983-01-01

    The best HVAC (heating, ventilating and air conditioning) subsystem to interface with the Engelhard fuel cell system for application in commercial buildings was determined. To accomplish this objective, the effects of several system and site specific parameters on the economic feasibility of fuel cell/HVAC systems were investigated. An energy flow diagram of a fuel cell/HVAC system is shown. The fuel cell system provides electricity for an electric water chiller and for domestic electric needs. Supplemental electricity is purchased from the utility if needed. An excess of electricity generated by the fuel cell system can be sold to the utility. The fuel cell system also provides thermal energy which can be used for absorption cooling, space heating and domestic hot water. Thermal storage can be incorporated into the system. Thermal energy is also provided by an auxiliary boiler if needed to supplement the fuel cell system output. Fuel cell/HVAC systems were analyzed with the TRACE computer program.

  18. 'Integration'

    DEFF Research Database (Denmark)

    Olwig, Karen Fog

    2011-01-01

    , while the countries have adopted disparate policies and ideologies, differences in the actual treatment and attitudes towards immigrants and refugees in everyday life are less clear, due to parallel integration programmes based on strong similarities in the welfare systems and in cultural notions...... of equality in the three societies. Finally, it shows that family relations play a central role in immigrants’ and refugees’ establishment of a new life in the receiving societies, even though the welfare society takes on many of the social and economic functions of the family....

  19. Assessment of On-Site Power Opportunities in the Industrial Sector; TOPICAL

    International Nuclear Information System (INIS)

    Bryson, T.

    2001-01-01

    The purpose of this report is to identify the potential for on-site power generation in the U.S. industrial sector with emphasis on nine industrial groups called the ''Industries of the Future'' (IOFs) by the U.S. Department of Energy (DOE). Through its Office of Industrial Technologies (OIT), the DOE has teamed with the IOFs to develop collaborative strategies for improving productivity, global competitiveness, energy usage and environmental performance. Total purchases for electricity and steam for the IOFs are in excess of$27 billion annually. Energy-related costs are very significant for these industries. The nine industrial groups are: (1) Agriculture (SIC 1); (2) Forest products; (3) Lumber and wood products (SIC 24); (4) Paper and allied products (SIC 26); (5) Mining (SIC 11, 12, 14); (6) Glass (SIC 32); (7) Petroleum (SIC 29); (8) Chemicals (SIC 28); and (9) Metals (SIC 33)-Steel, Aluminum, Metal casting. Although not currently part of the IOF program, the food industry is included in this report because of its close relationship to the agricultural industry and its success with on-site power generation. On-site generation provides an alternative means to reduce energy costs, comply with environmental regulations, and ensure a reliable power supply. On-site generation can ease congestion in the local utility's electric grid. Electric market restructuring is exacerbating the price premium for peak electricity use and for reliability, creating considerable market interest in on-site generation

  20. Totally James

    Science.gov (United States)

    Owens, Tom

    2006-01-01

    This article presents an interview with James Howe, author of "The Misfits" and "Totally Joe". In this interview, Howe discusses tolerance, diversity and the parallels between his own life and his literature. Howe's four books in addition to "The Misfits" and "Totally Joe" and his list of recommended books with lesbian, gay, bisexual, transgender,…

  1. International Symposium on Site Characterization for CO2Geological Storage

    Energy Technology Data Exchange (ETDEWEB)

    Tsang, Chin-Fu

    2006-02-23

    Several technological options have been proposed to stabilize atmospheric concentrations of CO{sub 2}. One proposed remedy is to separate and capture CO{sub 2} from fossil-fuel power plants and other stationary industrial sources and to inject the CO{sub 2} into deep subsurface formations for long-term storage and sequestration. Characterization of geologic formations for sequestration of large quantities of CO{sub 2} needs to be carefully considered to ensure that sites are suitable for long-term storage and that there will be no adverse impacts to human health or the environment. The Intergovernmental Panel on Climate Change (IPCC) Special Report on Carbon Dioxide Capture and Storage (Final Draft, October 2005) states that ''Site characterization, selection and performance prediction are crucial for successful geological storage. Before selecting a site, the geological setting must be characterized to determine if the overlying cap rock will provide an effective seal, if there is a sufficiently voluminous and permeable storage formation, and whether any abandoned or active wells will compromise the integrity of the seal. Moreover, the availability of good site characterization data is critical for the reliability of models''. This International Symposium on Site Characterization for CO{sub 2} Geological Storage (CO2SC) addresses the particular issue of site characterization and site selection related to the geologic storage of carbon dioxide. Presentations and discussions cover the various aspects associated with characterization and selection of potential CO{sub 2} storage sites, with emphasis on advances in process understanding, development of measurement methods, identification of key site features and parameters, site characterization strategies, and case studies.

  2. Managing the risks of on-site health centers.

    Science.gov (United States)

    Gorman, Kathleen M; Miller, Ross M

    2011-11-01

    This review sought to assess compliance concerns, determine risk management strategies, and identify opportunities for future research to contribute to employers' understanding of the laws and regulations that apply to on-site care. A comprehensive review of databases, professional organizations' websites, and journals resulted in 22 publications reporting on the consequences of noncompliance among on-site health centers accepted for inclusion. None of those studies reported a study design or quantifiable outcome data. Two noncompliance themes were repeated among the publications. First, direct penalties included fines, civil actions, loss of licensure, and, potentially, criminal charges. Second, noncompliance also resulted in indirect costs such as employee mistrust and lowered standards of care, which jeopardize on-site health centers' ability to demonstrate a return on investment. Further research with rigorous methodology is needed to inform employer decisions about on-site health services and associated risk management. Copyright 2011, SLACK Incorporated.

  3. On site clean up with a hazardous waste incinerator

    International Nuclear Information System (INIS)

    Cross, F.L. Jr.; Tessitore, J.L.

    1987-01-01

    The Army Corps of Engineers and the EPA have determined that on-site incineration for the detoxification of soils, sediments, and sludges is a viable, safe, and economic alternative. This paper discusses an approach to on-site incineration as a method of detoxification of soils/sediments contaminated with organic hazardous wastes. Specifically, this paper describes the procedures used to evaluate on-site incineration at a large Superfund site with extensive PCB contaminated soils and sediments. The paper includes the following: (1) a discussion of site waste quantities and properties, (2) a selection of an incineration technology with a resulting concept and design, (3) a discussion of incinerator permitting requirements, (4) discussion and rationale for an incinerator sub-scale testing approach, and (5) analysis of on-site incineration cost

  4. Predicting on-site environmental impacts of municipal engineering works

    OpenAIRE

    Gangolells Solanellas, Marta; Casals Casanova, Miquel; Forcada Matheu, Núria; Macarulla Martí, Marcel

    2014-01-01

    The research findings fill a gap in the body of knowledge by presenting an effective way to evaluate the significance of on-site environmental impacts of municipal engineering works prior to the construction stage. First, 42 on-site environmental impacts of municipal engineering works were identified by means of a process-oriented approach. Then, 46 indicators and their corresponding significance limits were determined on the basis of a statistical analysis of 25 new-build and remodelling mun...

  5. Predicting on-site environmental impacts of municipal engineering works

    International Nuclear Information System (INIS)

    Gangolells, Marta; Casals, Miquel; Forcada, Núria; Macarulla, Marcel

    2014-01-01

    The research findings fill a gap in the body of knowledge by presenting an effective way to evaluate the significance of on-site environmental impacts of municipal engineering works prior to the construction stage. First, 42 on-site environmental impacts of municipal engineering works were identified by means of a process-oriented approach. Then, 46 indicators and their corresponding significance limits were determined on the basis of a statistical analysis of 25 new-build and remodelling municipal engineering projects. In order to ensure the objectivity of the assessment process, direct and indirect indicators were always based on quantitative data from the municipal engineering project documents. Finally, two case studies were analysed and found to illustrate the practical use of the proposed model. The model highlights the significant environmental impacts of a particular municipal engineering project prior to the construction stage. Consequently, preventive actions can be planned and implemented during on-site activities. The results of the model also allow a comparison of proposed municipal engineering projects and alternatives with respect to the overall on-site environmental impact and the absolute importance of a particular environmental aspect. These findings are useful within the framework of the environmental impact assessment process, as they help to improve the identification and evaluation of on-site environmental aspects of municipal engineering works. The findings may also be of use to construction companies that are willing to implement an environmental management system or simply wish to improve on-site environmental performance in municipal engineering projects. -- Highlights: • We present a model to predict the environmental impacts of municipal engineering works. • It highlights significant on-site environmental impacts prior to the construction stage. • Findings are useful within the environmental impact assessment process. • They also

  6. Predicting on-site environmental impacts of municipal engineering works

    Energy Technology Data Exchange (ETDEWEB)

    Gangolells, Marta, E-mail: marta.gangolells@upc.edu; Casals, Miquel, E-mail: miquel.casals@upc.edu; Forcada, Núria, E-mail: nuria.forcada@upc.edu; Macarulla, Marcel, E-mail: marcel.macarulla@upc.edu

    2014-01-15

    The research findings fill a gap in the body of knowledge by presenting an effective way to evaluate the significance of on-site environmental impacts of municipal engineering works prior to the construction stage. First, 42 on-site environmental impacts of municipal engineering works were identified by means of a process-oriented approach. Then, 46 indicators and their corresponding significance limits were determined on the basis of a statistical analysis of 25 new-build and remodelling municipal engineering projects. In order to ensure the objectivity of the assessment process, direct and indirect indicators were always based on quantitative data from the municipal engineering project documents. Finally, two case studies were analysed and found to illustrate the practical use of the proposed model. The model highlights the significant environmental impacts of a particular municipal engineering project prior to the construction stage. Consequently, preventive actions can be planned and implemented during on-site activities. The results of the model also allow a comparison of proposed municipal engineering projects and alternatives with respect to the overall on-site environmental impact and the absolute importance of a particular environmental aspect. These findings are useful within the framework of the environmental impact assessment process, as they help to improve the identification and evaluation of on-site environmental aspects of municipal engineering works. The findings may also be of use to construction companies that are willing to implement an environmental management system or simply wish to improve on-site environmental performance in municipal engineering projects. -- Highlights: • We present a model to predict the environmental impacts of municipal engineering works. • It highlights significant on-site environmental impacts prior to the construction stage. • Findings are useful within the environmental impact assessment process. • They also

  7. 2009 Melbourne metropolitan sewerage strategy: a portfolio of decentralised and on-site concept designs.

    Science.gov (United States)

    Brown, V; Jackson, D W; Khalifé, M

    2010-01-01

    The bulk and retail water companies of the greater Melbourne area are developing the 2009 Metropolitan Sewerage Strategy to provide sustainable sewerage services to 2060. The objective of the strategy is to establish long term principles and near term actions to produce a robust sewage management system for Melbourne. Melbourne's existing sewerage system is largely centralised and discharges to two major treatment plants. Several small satellite treatment plants service local urban areas generally more distant from the centralised system. Decentralised and on-site wastewater systems are options for future sewage management and could play a role in local recycling. A portfolio of 18 on-site and decentralised concept designs was developed, applicable to the full range of urban development types in Melbourne. The concepts can be used in evaluation of metropolitan system configurations as part of future integrated water cycle planning. The options included secondary and tertiary treatment systems incorporating re-use of water for non potable uses, urine separation, black and greywater separation and composting toilets. On-site and cluster treatment systems were analysed. Each option is described by its indicative capital and operating costs, energy use and water and nutrient balances. This paper summarises and compares the portfolio mix of decentralized and on-site options in Melbourne's context.

  8. Comparing the Scoring of Human Decomposition from Digital Images to Scoring Using On-site Observations.

    Science.gov (United States)

    Dabbs, Gretchen R; Bytheway, Joan A; Connor, Melissa

    2017-09-01

    When in forensic casework or empirical research in-person assessment of human decomposition is not possible, the sensible substitution is color photographic images. To date, no research has confirmed the utility of color photographic images as a proxy for in situ observation of the level of decomposition. Sixteen observers scored photographs of 13 human cadavers in varying decomposition stages (PMI 2-186 days) using the Total Body Score system (total n = 929 observations). The on-site TBS was compared with recorded observations from digital color images using a paired samples t-test. The average difference between on-site and photographic observations was -0.20 (t = -1.679, df = 928, p = 0.094). Individually, only two observers, both students with human decomposition based on digital images can be substituted for assessments based on observation of the corpse in situ, when necessary. © 2017 American Academy of Forensic Sciences.

  9. 76 FR 29274 - Interstate Electronics Corp., a Subsidiary of L-3 Communications Including On-Site Leased Workers...

    Science.gov (United States)

    2011-05-20

    ... Resources, Systems Pros, Total Tech Services, Triple Crown Consulting, and Ingenium Technology, Inc... Resources, PDS Technical Service, Superior Technical Resources, Systems Pros, Total Tech Services, and... subject firm. The company reports that workers leased from Ingenium Technology, Inc. were employed on-site...

  10. On-site disposal as a decommissioning strategy

    International Nuclear Information System (INIS)

    1999-11-01

    On-site disposal is not a novel decommissioning strategy in the history of the nuclear industry. Several projects based on this strategy have been implemented. Moreover, a number of studies and proposals have explored variations within the strategy, ranging from in situ disposal of entire facilities or portions thereof to disposal within the site boundary of major components such as the reactor pressure vessel or steam generators. Regardless of these initiatives, and despite a significant potential for dose, radioactive waste and cost reduction, on-site disposal has often been disregarded as a viable decommissioning strategy, generally as the result of environmental and other public concerns. Little attention has been given to on-site disposal in previous IAEA publications in the field of decommissioning. The objective of this report is to establish an awareness of technical factors that may or may not favour the adoption of on-site disposal as a decommissioning strategy. In addition, this report presents an overview of relevant national experiences, studies and proposals. The expected end result is to show that, subject to safety and environmental protection assessment, on-site disposal can be a viable decommissioning option and should be taken into consideration in decision making

  11. Mosses as an integrating tool for monitoring PAH atmospheric deposition: comparison with total deposition and evaluation of bioconcentration factors. A year-long case-study.

    Science.gov (United States)

    Foan, Louise; Domercq, Maria; Bermejo, Raúl; Santamaría, Jesús Miguel; Simon, Valérie

    2015-01-01

    Polycyclic aromatic hydrocarbon (PAH) atmospheric deposition was evaluated at a remote site in Northern Spain using moss biomonitoring with Hylocomium splendens (Hedw.) Schimp., and by measuring the total deposition fluxes of PAHs. The year-long study allowed seasonal variations of PAH content in mosses to be observed, and these followed a similar trend to those of PAH fluxes in total deposition. Generally, atmospheric deposition of PAHs is greater in winter than in summer, due to more PAH emissions from domestic heating, less photoreactivity of the compounds, and intense leaching of the atmosphere by wet deposition. However, fractionation of these molecules between the environmental compartments occurs: PAH fluxes in total deposition and PAH concentrations in mosses are correlated with their solubility (r=0.852, pPAH fluxes can be estimated with moss biomonitoring data if the bioconcentration or 'enriching' factors are known. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Total quality in spent fuel pool reracking

    International Nuclear Information System (INIS)

    Cranston, J.S.; Bradbury, R.B.; Cacciapouti, R.J.

    1993-01-01

    The nuclear utility environment is one of strict cost control under prescriptive regulations and increasing public scrutiny. This paper presents the results of A Total Quality approach, by a dedicated team, that addresses the need for increased on-site spent fuel storage in this environment. Innovations to spent fuel pool reracking, driven by utilities' specific technical needs and shrinking budgets, have resulted in both product improvements and lower prices. A Total Quality approach to the entire turnkey project is taken, thereby creating synergism and process efficiency in each of the major phases of the project: design and analysis, licensing, fabrication, installation and disposal. Specific technical advances and the proven quality of the team members minimizes risk to the utility and its shareholders and provides a complete, cost effective service. Proper evaluation of spent fuel storage methods and vendors requires a full understanding of currently available customer driven initiatives that reduce cost while improving quality. In all phases of a spent fuel reracking project, from new rack design and analysis through old rack disposal, the integration of diverse experts, at all levels and throughout all phases of a reracking project, better serves utility needs. This Total Quality environment in conjunction with many technical improvements results in a higher quality product at a lower cost

  13. 1000kW on-site PAFC power plant development and demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Satomi, Tomohide; Koike, Shunichi [Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA), Osaka (Japan); Ishikawa, Ryou [New Energy and Industrial Technology Development Organization (NEDO), Tokyo (Japan)

    1996-12-31

    Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA) and New Energy and Industrial Technology Development Organization (NEDO) have been conducting a joint project on development of a 5000kW urban energy center type PAFC power plant (pressurized) and a 1000kW on-site PAFC power plant (non-pressurized). The objective of the technical development of 1000kW on-site PAFC power plant is to realize a medium size power plant with an overall efficiency of over 70% and an electrical efficiency of over 36%, that could be installed in a large building as a cogeneration system. The components and system integration development work and the plant design were performed in 1991 and 1992. Manufacturing of the plant and installation at the test site were completed in 1994. PAC test was carried out in 1994, and generation test was started in January 1995. Demonstration test is scheduled for 1995 and 1996.

  14. Number of on-site personnel and their functions

    International Nuclear Information System (INIS)

    Recker, M.

    1986-01-01

    After the definition of the general tasks, the development of an organization chart for on-site personnel is shown, the number and qualifications are indicated relating to the specific jobs. The functions of the different people are explained in detail. (orig.)

  15. Local Area Artworks: Collaborative Art Interpretation On-Site

    DEFF Research Database (Denmark)

    Polli, Anna Maria; Korn, Matthias; Klokmose, Clemens Nylandsted

    2013-01-01

    In this paper we present Local Area Artworks, a system enabling collaborative art interpretation on-site deployed during an exhibition in a local art gallery. Through the system, we explore ways to re-connect people to the local place by making use of their personal mobile devices as interfaces...

  16. In-situ and on-site technologies; An overview

    Energy Technology Data Exchange (ETDEWEB)

    Freestone, F J [Technical Support Branch, ORD, RREL, U.S. EPA, Edison, New Jersey (US)

    1990-01-01

    A broad analysis of and perspective on the characteristics and measured performance of in-situ and on-site treatment technologies available for remediation of contaminated soils, groundwater and associated debris at hazardous waste sites. Included in the analysis is information from U.S. and European sources. Available data are appended from nine recently completed field demonstrations from the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) program. The most frequently applied technology areas appear to be on-site thermal treatment for organics, on-site and in-situ solidification/stabilization technologies for most inorganics and metals, traditional on-site water treatment techniques, and soil vapor extraction for volatile organic compounds. Rapidly developing areas include bioremediation technologies, and concentration technologies. Two of the weakest areas include materials handling for such situations as excavating buried drums and soils with volatiles safely, and performing physical and chemical site characterization using technology-sensitive parameters. An area worthy of international cooperatin is that of performing benchscale screening and treatability studies, including the specification of key parameters needing measurement, techniques for such measurement and for interpretation, storage and retrieval of resulting data. We are in the process of evaluating existing treatability study data on soils and debris, and will be installing that data onto an on-line information system available to the public world-wide. (AB) 10 refs.

  17. 75 FR 38127 - Visteon Systems, LLC North Penn Plant Electronics Products Group Including On-Site Leased Workers...

    Science.gov (United States)

    2010-07-01

    ..., North Penn Plant, Electronics Products Group to be covered by this certification. The intent of the... North Penn Plant Electronics Products Group Including On-Site Leased Workers From Ryder Integrated... Certification Regarding Eligibility To Apply for Worker Adjustment Assistance and Alternative Trade Adjustment...

  18. Total Thyroidectomy

    Directory of Open Access Journals (Sweden)

    Lopez Moris E

    2016-06-01

    Full Text Available Total thyroidectomy is a surgery that removes all the thyroid tissue from the patient. The suspect of cancer in a thyroid nodule is the most frequent indication and it is presume when previous fine needle puncture is positive or a goiter has significant volume increase or symptomes. Less frequent indications are hyperthyroidism when it is refractory to treatment with Iodine 131 or it is contraindicated, and in cases of symptomatic thyroiditis. The thyroid gland has an important anatomic relation whith the inferior laryngeal nerve and the parathyroid glands, for this reason it is imperative to perform extremely meticulous dissection to recognize each one of these elements and ensure their preservation. It is also essential to maintain strict hemostasis, in order to avoid any postoperative bleeding that could lead to a suffocating neck hematoma, feared complication that represents a surgical emergency and endangers the patient’s life.It is essential to run a formal technique, without skipping steps, and maintain prudence and patience that should rule any surgical act.

  19. A study of integrated learning and the value of science in remote education: using the Internet to relay the total solar eclipse of 2001 June 11 in Africa

    Science.gov (United States)

    Takahashi, N.; Agata, H.; Maeda, K.; Okyudo, M..; Yamazaki, Y.

    A total solar eclipse was observed on 2001 June 21 in Angola, Zambia, and Zimbabwe in Africa. For the purpose of promotion of science education using a solar eclipse as an educational project, the whole image and an enlarged image of the Sun, that showed the process of an eclipse and how things went in the observation area, were broadcast to the world through the Internet (Live Eclipse). Such images were distributed to four primary schools in Hiroshima and the Science and Technology Museum in Tokyo to give a remote lecture through computers. To find the effectiveness of the lecture, the learning effect on the participating children was examined two times before and after the remote lecture on the solar eclipse.

  20. Integration of In-Flight and Post-Flight Water Monitoring Resources in Addressing the U.S. Water Processor Assembly Total Organic Carbon (TOC) Anomaly

    Science.gov (United States)

    Straub, John E., II; McCly, J. Torin

    2011-01-01

    Beginning in June of 2010, the total organic carbon (TOC) concentration in the U.S. Water Processor Assembly (WPA) product water started to increase. A surprisingly consistent upward TOC trend was observed through weekly ISS total organic carbon analyzer (TOCA) monitoring. As TOC is a general organic compound indicator, return of water archive samples was needed to make better-informed crew health decisions on the specific compounds of concern and to aid in WPA troubleshooting. TOCA-measured TOC was more than halfway to the health-based screening limit of 3,000 g/L before archive samples were returned. Archive samples were returned on 22 Soyuz in September 2010 and on ULF5 in November of 2010. The samples were subjected to extensive analysis. Although TOC was confirmed to be elevated, somewhat surprisingly, none of the typical target compounds were detected at high levels. After some solid detective work, it was confirmed that the TOC was associated with a compound known as dimethylsilanediol (DMSD). DMSD is believed to be a breakdown product of siloxanes which are thought to be ubiquitous in the ISS atmosphere. A toxicological limit was set for DMSD and a forward plan was developed for conducting operations in the context of understanding the composition of the TOC measured in flight. This required careful consideration of existing ISS flight rules, coordination with ISS stakeholders, and development of a novel approach for the blending of inflight TOCA data with archive results to protect crew health. Among other challenges, team members had to determine how to utilize TOCA readings when making decisions about crew consumption of WPA water. This involved balancing very real concerns associated with the assumption that TOC would continue to be comprised of only DMSD. Demonstrated teamwork, multidisciplinary awareness, and innovative problem-solving were required to respond effectively to this anomaly.

  1. The feasibility of mobile computing for on-site inspection.

    Energy Technology Data Exchange (ETDEWEB)

    Horak, Karl Emanuel; DeLand, Sharon Marie; Blair, Dianna Sue

    2014-09-01

    With over 5 billion cellphones in a world of 7 billion inhabitants, mobile phones are the most quickly adopted consumer technology in the history of the world. Miniaturized, power-efficient sensors, especially video-capable cameras, are becoming extremely widespread, especially when one factors in wearable technology like Apples Pebble, GoPro video systems, Google Glass, and lifeloggers. Tablet computers are becoming more common, lighter weight, and power-efficient. In this report the authors explore recent developments in mobile computing and their potential application to on-site inspection for arms control verification and treaty compliance determination. We examine how such technology can effectively be applied to current and potential future inspection regimes. Use cases are given for both host-escort and inspection teams. The results of field trials and their implications for on-site inspections are discussed.

  2. On-site tests on the nuclear power plants

    International Nuclear Information System (INIS)

    Morilhat, P.; Favennec, J.M.; Neau, P.; Preudhomme, E.

    1996-01-01

    On-site tests and experiments are performed by EDF Research and Development Division on the nuclear power plants to assess the behaviour of major components submitted to thermal and vibratory solicitations. On-going studies deal with the qualification of new nuclear power plant standard and with the feedback of plants under operation. The tests, particularly the investigation tests, correspond to large investments and entail an important data volume which must ensure the continuity over a long period of the order of magnitude of the in-service plant life (around 40 years). This paper addresses the on-site experimental activities, describes the means to be used, and gives an example: the qualification of SG of new 1450 MW nuclear power plants. (author)

  3. The development of an on-site container

    International Nuclear Information System (INIS)

    Glass, R.E.; McAllaster, M.E.; Jones, P.L.; McKinney, A.L.

    1992-01-01

    Sandia National Laboratories (SNL) has developed a package for the on-site transport of chemical munitions for the US Army. This package was designed to prevent the release of lethal quantities of chemical agents during transportation of munitions to the demilitarization facilities on-site. The packaging prevents auto-ignition of the munitions by limiting the thermal and structural assault on the munitions during an accident. This package, with some modifications to account for contents, may be suitable for the on-site transport of mixed wastes at United States Department of Energy facilities. This paper discusses the design and verification testing of the package. The safety criteria for the package were modeled after the International Atomic Energy Agency (IAEA) hypothetical accident sequence and modified to take credit for operational controls. The modified accident sequence consisted of drop, puncture, and thermal events. The post-accident leak rate was established to prevent harm to an exposed worker. The packaging has a mass of 8600 kg and can accommodate up to 3600 kg of contents. The interior of the package is 188 cm in diameter and 232 cm long. Two sample ports can be used to sample the interior of the package prior to opening the closure and an o-ring test port can be used to determine the leak rates prior to and after transport

  4. Implementing solutions to barriers to on-site HIV testing in substance abuse treatment: a tale of three facilities.

    Science.gov (United States)

    Hood, Kristina B; Robertson, Angela A; Baird-Thomas, Connie

    2015-04-01

    Due to the scarcity of resources for implementing rapid on-site HIV testing, many substance abuse treatment programs do not offer these services. This study sought to determine whether addressing previously identified implementation barriers to integrating on-site rapid HIV testing into the treatment admissions process would increase offer and acceptance rates. Results indicate that it is feasible to integrate rapid HIV testing into existing treatment programs for substance abusers when resources are provided. Addressing barriers such as providing start-up costs for HIV testing, staff training, addressing staffing needs to reduce competing job responsibilities, and helping treatment staff members overcome their concerns about clients' reactions to positive test results is paramount for the integration and maintenance of such programs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. 76 FR 35025 - Nokia, Inc.; a Subsidiary of Nokia Group; Including On-Site Leased Workers From ATC Logistics and...

    Science.gov (United States)

    2011-06-15

    ... of Nokia Group; Including On-Site Leased Workers From ATC Logistics and Electronics and Adecco Fort... workers from ATC Logistics and Electronics, Fort Worth, Texas. The workers supplied planning and materials... ATC Logistics and Electronics, and Adecco, Fort Worth, Texas, who became totally or partially...

  6. 76 FR 61740 - Geneon Entertainment (USA) Including On-Site Leased Workers From Interplace, Inc., Apple One and...

    Science.gov (United States)

    2011-10-05

    ...) Including On-Site Leased Workers From Interplace, Inc., Apple One and Robert Half Legal Santa Monica, CA...-site leased workers from Interplace, Inc., and Apple One, Santa Monica, California. The workers are... from Interplace, Inc., Apple One and Robert Half Legal, Santa Monica, California, who became totally or...

  7. Shielding requirements on-site loading and acceptance testing on the Leksell gamma knife

    International Nuclear Information System (INIS)

    Maitz, A.H.; Lunsford, L.D.; Wu, A.; Lindner, G.; Flickinger, J.C.

    1990-01-01

    On August 14, 1987, the first stereotactic radiosurgical procedure using the gamma knife was performed in North America. Located in a self-contained radiosurgical suite in the basement of Presbyterian-University Hospital in Pittsburgh, Pennsylvania. This device uses 201 highly focused beams 60Co for the single-treatment closed-skull irradiation of brain lesions localized by stereotactic techniques (radiosurgery). One hundred and fifty-two patients with intracranial arteriovenous malformations or brain tumors were treated in the first year of operation. The Presbyterian University Hospital of Pittsburgh gamma knife is the first such unit in which the 60Co sources were loaded on-site. This effort required us to solve some difficult and unusual problems encountered during site preparation, delivery, and loading of the unit in a busy hospital setting. The solutions developed enabled installation and use of the gamma knife with minimal disruption of hospital activities while maintaining acceptable levels of exposure to radiation. Environmental surveys performed during the loading of the 201 radioactive sources (total, 219 TBq) confirmed that on-site loading is possible and practical. Our experience in the design, construction, and implementation of the first North American gamma knife supports the practicality and safety of on-site loading and may be of value in the planning and development of future gamma knife installations

  8. Noble Gas Sampling and Detection Methods for On-Site Inspections in Support of CTBT

    International Nuclear Information System (INIS)

    Wieslander, J.S.E.

    2015-01-01

    The On-Site Inspections (OSI) constitutes the final verification measure under the CTBT, and are conducted to verify States Parties' compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT). An on-site inspection is launched to establish whether or not a nuclear explosion has been carried out and during such an inspection, facts might also be gathered to identify a possible violator of the Treaty. The Treaty lists all activities and techniques that are permitted and one of these is the environmental sampling of noble gases (NG) in the air and underground, which can be deployed at any time during an OSI. The CTBT relevant isotopes are Xe-133, 133m, 131m, 135 and Ar-37. The samples are primarily to be analyzed on-site, although the treaty also allows off-site analysis in designated laboratories if necessary. Stringent procedures ensure the security, integrity and confidentiality of the samples throughout the sampling and analysis process — all taking place in the field. Over the past decade the techniques for NG sampling, processing and analysis of both atmospheric and subsoil NG samples have been developed further in order to fit to the conditions and requirements during an OSI. This has been a major international effort with a global set of collaborators. Especially during the past three years the efforts intensified in order to finalize the scientific and technical developments for the Integrated Field Exercise, November 2014 (IFE14). This presentation will provide an overview of the current status of the OSI NG sampling regime and the OSI NG Field Laboratory to be deployed in IFE14, together with more technical descriptions of methods and equipment as well as a short discussion on potential future developments and alternative applications as applicable. (author)

  9. Scattering angle-integrated (total) and magnetic sublevel cross-sections and degree of linear polarization for electron and proton induced excitation [HeI (1snp) sup 1 P sup 0 (n=2-5)] of helium

    CERN Document Server

    Merabet, H; Hanni, J; Bailey, M; Godunov, A L; McGuire, J H; Fursa, D V; Bray, I; Bartschat, K; Tseng, H C; Lin, C D

    2003-01-01

    Experimental scattering-angle-integrated (total) cross-sections sigma-bar, (scattering) angle-integrated magnetic sublevel cross-sections sigma-bar sub M sub sub L , and degree of linear polarization data have been measured in the extreme ultraviolet (EUV) wavelength region following decay of HeI (1snp) sup 1 P sup 0 (n=2-5) states induced by electron and proton impact on a neutral helium target. These measurements are compared with a first Born approach as well as more sophisticated theoretical calculations. Specifically, theoretical values for electron impact include convergent close-coupling (CCC) and R-matrix with pseudo states (RMPS) methods in addition to first Born (Born 1) approximation while proton induced excitation cross-sections are compared with atomic-orbital close-coupling (AOCC) and first Born predictions.

  10. On-site worker-risk calculations using MACCS

    International Nuclear Information System (INIS)

    Peterson, V.L.

    1993-01-01

    We have revised the latest version of MACCS for use with the calculation of doses and health risks to on-site workers for postulated accidents at the Rocky Flats Plant (RFP) in Colorado. The modifications fall into two areas: (1) an improved estimate of shielding offered by buildings to workers that remain indoors; and, (2) an improved treatment of building-wake effects, which affects both indoor and outdoor workers. Because the postulated accident can be anywhere on plant site, user-friendly software has been developed to create those portions of the (revised) MACCS input data files that are specific to the accident site

  11. Total Product Life Cycle (TPLC)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Total Product Life Cycle (TPLC) database integrates premarket and postmarket data about medical devices. It includes information pulled from CDRH databases...

  12. The development of an on-site container

    International Nuclear Information System (INIS)

    Glass, R.E.; McAllaster, M.E.; Jones, P.L.; McKinney, A.L.

    1993-01-01

    This paper describes the results of the development of a packaging designed for on-site transportation of chemical munitions. The criteria for the package were patterned after the requirements for Type B packagings, but were modified to take credit for the operational controls that could be applied on-site. The design phase has been completed and a contract has been placed for fabrication of 165 units. In addition to the tests completed during the design phase, a complete sequence of verification tests will be performed on the first fleet unit. This sequence will consist of: (1) a 22,700-kg load placed on the packaging for 24 hours, (2) the flat side free drop, (3) the center-of-gravity over closure joint puncture test, and (4) a 15-min all-engulfing JP-4 pool-fire test. At the completion of the test sequence, the package will be required to meet the less than 1 x 10 -1 std cc/s leak test. (J.P.N.)

  13. Laboratory and On-Site Tests for Rapid Runway Repair

    Directory of Open Access Journals (Sweden)

    Federico Leonelli

    2017-11-01

    Full Text Available The attention to rapid pavement repair has grown fast in recent decades: this topic is strategic for the airport management process for civil purposes and peacekeeping missions. This work presents the results of laboratory and on-site tests for rapid runway repair, in order to analyse and compare technical and mechanical performances of 12 different materials currently used in airport. The study focuses on site repairs, a technique adopted most frequently than repairs with modular elements. After describing mechanical and physical properties of the examined materials (2 bituminous emulsions, 5 cement mortars, 4 cold bituminous mixtures and 1 expanding resin, the study presents the results of carried out mechanical tests. The results demonstrate that the best performing material is a one-component fast setting and hardening cement mortar with graded aggregates. This material allows the runway reopening 6 h after the work. A cold bituminous mixture (bicomponent premixed cold asphalt with water as catalyst and the ordinary cement concrete allow the reopening to traffic after 18 h, but both ensure a lower service life (1000 coverages than the cement mortar (10,000 coverages. The obtained results include important information both laboratory level and field, and they could be used by airport management bodies and road agencies when scheduling and evaluating pavement repairs.

  14. Portable Infrared Laser Spectroscopy for On-site Mycotoxin Analysis

    Science.gov (United States)

    Sieger, Markus; Kos, Gregor; Sulyok, Michael; Godejohann, Matthias; Krska, Rudolf; Mizaikoff, Boris

    2017-03-01

    Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B1 affected peanuts at EU regulatory limits of 1250 μg kg-1 and 8 μg kg-1, respectively.

  15. 37Ar monitoring techniques and on-site inspection system

    International Nuclear Information System (INIS)

    Duan Rongliang; Chen Yinliang; Li Wei; Wang Hongxia; Hao Fanhua

    2001-01-01

    37 Ar is separated, purified and extracted from air sample with a low temperature gas-solid chromatographic purifying method, prepared into a radioactive measurement source and its radioactivity is measured with a proportional counter. Based on the monitoring result, a judgement can be made if an nuclear explosion event has happened recently in a spectabilis area. A series of element techniques that are associated the monitoring of the trace element 37 Ar have been investigated and developed. Those techniques include leaked gas sampling, 37 Ar separation and purification, 37 Ar radioactivity measurement and the on-site inspection of 37 Ar. An advanced 37 Ar monitoring method has been developed, with which 200 liters of air can be treated in 2 hours with sensitivity of 0.01 Bq/L for 37 Ar radioactivity measurement. A practical 37 Ar On-site Inspection system has been developed. This research work may provide technical and equipment support for the verification protection, verification supervision and CTBT verification

  16. The On-Site Analysis of the Cherenkov Telescope Array

    CERN Document Server

    Bulgarelli, Andrea; Zoli, Andrea; Aboudan, Alessio; Rodríguez-Vázquez, Juan José; De Cesare, Giovanni; De Rosa, Adriano; Maier, Gernot; Lyard, Etienne; Bastieri, Denis; Lombardi, Saverio; Tosti, Gino; Bergamaschi, Sonia; Beneventano, Domenico; Lamanna, Giovanni; Jacquemier, Jean; Kosack, Karl; Antonelli, Lucio Angelo; Boisson, Catherine; Borkowski, Jerzy; Buson, Sara; Carosi, Alessandro; Conforti, Vito; Colomé, Pep; Reyes, Raquel de los; Dumm, Jon; Evans, Phil; Fortson, Lucy; Fuessling, Matthias; Gotz, Diego; Graciani, Ricardo; Gianotti, Fulvio; Grandi, Paola; Hinton, Jim; Humensky, Brian; Inoue, Susumu; Knödlseder, Jürgen; Flour, Thierry Le; Lindemann, Rico; Malaguti, Giuseppe; Markoff, Sera; Marisaldi, Martino; Neyroud, Nadine; Nicastro, Luciano; Ohm, Stefan; Osborne, Julian; Oya, Igor; Rodriguez, Jerome; Rosen, Simon; Ribo, Marc; Tacchini, Alessandro; Schüssler, Fabian; Stolarczyk, Thierry; Torresi, Eleonora; Testa, Vincenzo; Wegner, Peter

    2015-01-01

    The Cherenkov Telescope Array (CTA) observatory will be one of the largest ground-based very high-energy gamma-ray observatories. The On-Site Analysis will be the first CTA scientific analysis of data acquired from the array of telescopes, in both northern and southern sites. The On-Site Analysis will have two pipelines: the Level-A pipeline (also known as Real-Time Analysis, RTA) and the level-B one. The RTA performs data quality monitoring and must be able to issue automated alerts on variable and transient astrophysical sources within 30 seconds from the last acquired Cherenkov event that contributes to the alert, with a sensitivity not worse than the one achieved by the final pipeline by more than a factor of 3. The Level-B Analysis has a better sensitivity (not be worse than the final one by a factor of 2) and the results should be available within 10 hours from the acquisition of the data: for this reason this analysis could be performed at the end of an observation or next morning. The latency (in part...

  17. Status of small reactor designs without on-site refuelling

    International Nuclear Information System (INIS)

    2007-01-01

    There is an ongoing interest in member states in the development and application of small and medium sized reactors (SMRs). In the near term, most new NPPs are likely to be evolutionary designs building on proven systems while incorporating technological advances and often the economics of scale, resulting from the reactor outputs of up to 1600 MW(e). For the longer term, the focus is on innovative designs aiming to provide increased benefits in the areas of safety and security, non-proliferation, waste management, resource utilization and economy, as well as to offer a variety of energy products and flexibility in design, siting and fuel cycle options. Many innovative designs are reactors within the small-to-medium size range, having an equivalent electric power less than 700 MW(e) or even less than 300 MW(e). A distinct trend in design and technology development, accounting for about half of the SMR concepts developed worldwide, is represented by small reactors without on-site refuelling. Such reactors, also known as battery-type reactors, could operate without reloading and shuffling of fuel in the core over long periods, from 5 to 25 years and beyond. Upon the advice and with the support of IAEA member states, within its Programme 1 'Nuclear Power, Fuel Cycle, and Nuclear Science', the IAEA provides a forum for the exchange of information by experts and policy makers from industrialized and developing countries on the technical, economic, environmental, and social aspects of SMRs development and implementation in the 21st century, and makes this information available to all interested Member States by producing status reports and other publications dedicated to advances in SMR technology. The objective of this report is to provide Member States, including those just considering the initiation of nuclear power programmes and those already having practical experience in nuclear power, with a balanced and objective information on important development trends and

  18. Enhancement of on-site emergency diesel generator reliability

    International Nuclear Information System (INIS)

    Boner, G.L.; Hanners, H.W.

    1979-01-01

    The University of Dayton Research Institute has concluded a program designed to provide NRC/DOR with technical assistance in evaluating the factors leading to improved reliability of on-site emergency diesel generator (DG) units. The program consisted of a comprehensive review of DG maintenance and operating experience and a comparative evaluation of the DG manufacturer's recommendations. This information, will enable the NRC to improve the basis on which it makes regulatory decisions. The primary goal of the program is to better identify the main problem areas which decrease the reliability of the DG units and make recommendations. The report has attained the program objectives by identifying and discussing the more significant problems and presenting the recommended corrective actions. The identified problems have been categorized into three groups as a function of their significance

  19. CTBTO tests its on-site inspection regime in Kazakhstan

    International Nuclear Information System (INIS)

    2003-07-01

    The former Soviet Union's nuclear test site at Semipalatinsk in the east of today's Kazakhstan was closed down after Kazakhstan became an independent State in 1991. This region in the Kazakh steppe is deserted and pockmarked by countless craters, remnants of over 450 nuclear explosions that were detonated there. In September 2008, the area will start brimming with activity. Scientists, diplomats and journalists will arrive from all over the world to witness an endeavour in the Kazakh steppe that is of great significance for the safety of our planet. The organization that monitors the comprehensive ban on nuclear testing will conduct a large scale exercise to test one of the key elements of its global alarm system - on-site inspections.

  20. CASDAC system: On-Site Multiplexer user's guide

    International Nuclear Information System (INIS)

    Yamamoto, Yoichi; Koyama, Kinji

    1993-03-01

    The CASDAC (Containment and Surveillance Data Authenticated Communication) system has been developed by JAERI for nuclear safeguards and physical protection of nuclear material. This system is a remote monitoring system for continual verification of security and safeguards status of nuclear material. The CASDAC system consists of two subsystems, one of them is a Grand Command Center (GCC) subsystem and the other is a facility subsystem. This report describes the outline and usage of the On-Site Multiplexer (OSM), which controls all other equipments in a facility subsystem and communicates with the GCC. This work has been carried out in the framework of Japan Support Programme for Agency Safeguards (JASPAS) as a project, JA-1. (author)

  1. A risk evaluation model using on-site meteorological data

    International Nuclear Information System (INIS)

    Kang, C.S.

    1979-01-01

    A model is considered in order to evaluate the potential risk from a nuclear facility directly combining the on site meteorological data. The model is utilized to evaluate the environmental consequences from the routine releases during normal plant operation as well as following postulated accidental releases. The doses to individual and risks to the population-at-large are also analyzed in conjunction with design of rad-waste management and safety systems. It is observed that the conventional analysis, which is done in two separate unaffiliated phases of releases and atmospheric dispersion tends to result in unnecessary over-design of the systems because of high resultant doses calculated by multiplication of two extreme values. (author)

  2. 76 FR 13665 - Cambridge Tool & Die, Including On-Site Leased Workers From Action Total Staffing, Cambridge, OH...

    Science.gov (United States)

    2011-03-14

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,605] Cambridge Tool & Die... Eligibility To Apply for Worker Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974... of Cambridge Tool & Die, Cambridge, Ohio. The workers are engaged in the production of plastic...

  3. Integration of Demilitarization Contractors and Recyclers - Collateral Benefits of On-Site Training of Recyclers

    Science.gov (United States)

    2010-07-01

    item Spherical? Wedge Shaped? Cylindrical? These items are potentially very dangerous 29 Spherical = Not Good If found in a recycling yard, don’t...touch! Call 9-1-1 BLU-63 30 Wedge Shape = Not Good If found in a recycling yard, don’t touch! Call 9-1-1 M72M43 31 Cylindrical = Not Good If found in a

  4. TOTAL PERFORMANCE SCORECARD

    Directory of Open Access Journals (Sweden)

    Anca ȘERBAN

    2013-06-01

    Full Text Available The purpose of this paper is to present the evolution of the Balanced Scorecard from a measurement instrument to a strategic performance management tool and to highlight the advantages of implementing the Total Performance Scorecard, especially for Human Resource Management. The study has been accomplished using the methodology of bibliographic study and various secondary sources. Implementing the classical Balanced Scorecard indicated over the years, repeatedly failure. It can be indicated that the crucial level is determined by the learning and growth perspective. It has been developed from a human perspective, which focused on staff satisfaction, innovation perspective with focus on future developments. Integrating the Total Performance Scorecard in an overall framework assures the company’s success, by keeping track of the individual goals, the company’s objectives and strategic directions. Like this, individual identity can be linked to corporate brand, individual aspirations to business goals and individual learning objectives to needed organizational capabilities.

  5. On-site waste storage assuring the success of on-site, low-level nuclear waste storage

    International Nuclear Information System (INIS)

    Preston, E.L.

    1986-01-01

    Waste management has reached paramount importance in recent years. The successful management of radioactive waste is a key ingredient in the successful operation of any nuclear facility. This paper discusses the options available for on-site storage of low-level radioactive waste and those options that have been selected by the Department of Energy facilities operated by Martin Marietta Energy Systems, Inc. in Oak Ridge, Tennessee. The focus of the paper is on quality assurance (QA) features of waste management activities such as accountability and retrievability of waste materials and waste packages, retrievability of data, waste containment, safety and environmental monitoring. Technical performance and careful documentation of that performance are goals which can be achieved only through the cooperation of numerous individuals from waste generating and waste managing organizations, engineering, QA, and environmental management

  6. Impact of external events on site evaluation: a probabilistic approach

    International Nuclear Information System (INIS)

    Jaccarino, E.; Giuliani, P.; Zaffiro, C.

    1975-01-01

    A probabilistic method is proposed for definition of the reference external events of nuclear sites. The external events taken into account are earthquakes, floods and tornadoes. On the basis of the available historical data for each event it is possible to perform statistical analyses to determine the probability of occurrence on site of events of given characteristics. For earthquakes, the method of analysis takes into consideration both the annual frequency of seismic events in Italy and the probabilistic distribution of areas stricken by each event. For floods, the methods of analysis of hydrological data and the basic criteria for the determination of design events are discussed and the general lines of the hydraulic analysis of a nuclear site are shown. For tornadoes, the statistical analysis has been performed for the events which occurred in Italy during the last 40 years; these events have been classified according to an empirical intensity scale. The probability of each reference event should be a function of the potential radiological damage associated with the particular type of plant which must be installed on the site. Thus the reference event could be chosen such that for the whole of the national territory the risk for safety and environmental protection is the same. (author)

  7. On-site equipment and materials against CBRNE terrorism

    International Nuclear Information System (INIS)

    Yamamoto, Soichiro; Tokita, Kenichi

    2016-01-01

    There is no almighty field service equipment that can handle by itself all CBRNE (Chemical, Biological, Radiological, Nuclear, Explosive) terrorism. Since there is merit and demerit for each of equipment, operation methods and linkage of material/equipment based on detection principle are indispensable. This paper explained the principle and operation method of detection equipment, operation using multiple material/equipment, and system construction to facilitate cooperation with related ministries and agencies. There are six examples as typical material/equipment and detection principle for handling CBRNE as shown below: (1) ion mobility spectrometer, (2) infrared spectroscopy, (3) Raman scattering spectroscopy, (4) gas chromatographic mass spectrometry, (5) fluorescent reactive dye classification method, and (6) antigen antibody reaction method. This paper shows a flowchart that can measure within the duration of a respirator while wearing Level A protective clothing (about 15 to 20 min) by the combination of detector/analyzer based on these methods. The authors developed an information system that allows prompt information exchange between the on-site administrative agencies, research institutes, and other related organizations via network, in the case when substances etc. could not be specified in the above flowchart. (A.O.)

  8. Advanced on-site conceptual simulator for Forsmark 3

    International Nuclear Information System (INIS)

    Johansson, G.; Sjoestrand, K.

    1984-01-01

    On-site conceptual simulators have been extensively used at Swedish nuclear power plants. Despite having access to identical replica simulators, both the Swedish State Power Board and the Swedish private power industry have ordered conceptual simulators during 1982. The motivation has been that a complete training programme requires access to both a replica and a conceptual simulator. The replica simulator is perfect for training in control room behaviour but less appropriate for ensuring deeper process understanding. On the other hand, the conceptual simulator is not well suited for getting the personnel acquainted with the control room but is perfect for extending their knowledge of the plant processes. In order to give a realistic description of these processes, the conceptual simulator model must be fairly advanced. The Forsmark 3 conceptual simulator simulates the entire primary system, including the details of the steam and feedwater systems. Considerable attention has also been devoted to the presentation of calculated variables. For example, all the variables in the data base (approx. 6600) can be presented on colour-graphic CRTs as functions of time. (author)

  9. An On-Site Presentation of Invisible Prehistoric Landscapes

    Directory of Open Access Journals (Sweden)

    Jiri Unger

    2017-03-01

    Full Text Available The rapid development of information technology has enabled the creation of entirely new presentation frameworks and this article will attempt to explore the subject of on-site presentation of archaeological sites. The most frequently used environment currently has been in the form of a variety of virtual museums that are accessible on the Internet; in essence these keep their visitors stuck in front of a PC monitor. One option that allows leaving the monitor and stepping directly out-of-doors into a virtual open-air museum is by means of applications for mobile phones. Terms such as 'virtual' or 'augmented reality' no longer represent a million light-years away science-fiction concepts, but rather a new tool for public archaeology and for the preservation of the archaeological heritage. This article presents several projects that have been implemented by the Archaeological Institute in Prague, who, by using mobile applications, built virtual open-air museums directly in the locations of archaeological excavations.

  10. ON-SITE SOLID-PHASE EXTRACTION AND LABORATORY ...

    Science.gov (United States)

    Fragrance materials such as synthetic musks in aqueous samples, are normally determined by gas chromatography/mass spectrometry in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. Full-scan mass spectra are required to verify that a target analyte has been found by comparison with the mass spectra of fragrance compounds in the NIST mass spectral library. A I -L sample usually provides insufficient analyte for full scan data acquisition. This paper describes an on-site extraction method developed at the U.S. Environmental Protection Agency (USEPA)- Las Vegas Nevada - for synthetic musks from 60 L of wastewater effluent. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for a wide array of synthetic musks. Quantification of these compounds was achieved from the full-scan data directly, without the need to acquire SIM data. The detection limits obtained with this method are an order of magnitude lower than those obtained from liquid-liquid and other solid phase extraction methods. This method is highly reproducible, and recoveries ranged from 80 to 97% in spiked sewage treatment plant effluent. The high rate of sorbent-sample mass transfer eliminated the need for a methanolic activation step, which reduced extraction time, labor, and solvent use, More samples could be extracted in the field at lower cost. After swnple extraction, the light- weight cartridges ar

  11. Critical management practices influencing on-site waste minimization in construction projects.

    Science.gov (United States)

    Ajayi, Saheed O; Oyedele, Lukumon O; Bilal, Muhammad; Akinade, Olugbenga O; Alaka, Hafiz A; Owolabi, Hakeem A

    2017-01-01

    As a result of increasing recognition of effective site management as the strategic approach for achieving the required performance in construction projects, this study seeks to identify the key site management practices that are requisite for construction waste minimization. A mixed methods approach, involving field study and survey research were used as means of data collection. After confirmation of construct validity and reliability of scale, data analysis was carried out through a combination of Kruskal-Wallis test, descriptive statistics and exploratory factor analysis. The study suggests that site management functions could significantly reduce waste generation through strict adherence to project drawings, and by ensuring fewer or no design changes during construction process. Provision of waste skips for specific materials and maximisation of on-site reuse of materials are also found to be among the key factors for engendering waste minimization. The result of factor analysis suggests four factors underlying on-site waste management practices with 96.093% of total variance. These measures include contractual provisions for waste minimization, waste segregation, maximisation of materials reuse and effective logistic management. Strategies through which each of the underlying measures could be achieved are further discussed in the paper. Findings of this study would assist construction site managers and other site operatives in reducing waste generated by construction activities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Proposal for the award of a contract for the construction of an on-site hostel at CERN

    CERN Document Server

    2006-01-01

    This document concerns the award of a contract for the construction of an on-site hostel at CERN. The Finance Committee is invited to agree to the negotiation of a contract with the consortium BATIFLEX (GB) - BATINEG (CH), the lowest bidder, for the construction of an on-site hostel at CERN for a total amount of 5 290 000 Swiss francs, not subject to revision. However, for the reasons explained in this document, the Management wishes to request the Finance Committee to give consideration to the approval of a variant to the original specification to allow use to be made of part of an existing building for the reasons detailed in this document, at an additional cost of 350 000 Swiss francs, not subject to revision, bringing the total construction cost to 5 640 000 Swiss francs.

  13. 75 FR 3250 - Glaxosmithkline, Including On-Site Temporary and Leased Workers From Kelly Services, Kelly...

    Science.gov (United States)

    2010-01-20

    ... subject firm. The workers are engaged in the production of penicillin-based antibiotics for humans and animals. The company reports that on-site leased workers from Dream Clean, Inc. were employed on-site at...

  14. Project VISION (Very Intensive Scientific Intercurricular On-Site Education

    Science.gov (United States)

    Roig, Gustavo A.

    1999-01-01

    Project VISION (Very Intensive Scientific Intercurricular On-Site Education) is a joint effort among NASA/John F. Kennedy Space Center, Florida International University, Universidad del Turabo, Miami-Dade County Public Schools and the Caguas/Gurabo Public Schools in Puerto Rico. The project's main mission is to institutionalize change among the elementary and middle school science and math teachers at participating schools so that their students receive continuously enriched instruction in the principles of science and math through the use of hands-on and minds-on experiments called learning modules. These leaming modules incorporate the national science and math education standards provided by the National Committee on Science Education Standards and Assessments and the National Council of Teachers of Mathematics, respectively. The use of learning modules that require hands-on and minds-on activities in a classroom setting garners great enthusiasm and motivation on the part of the target students for the understanding of the lesson's underlying math and science principles. With this enthusiasm and motivation, comes acceptance, attention, participation, discipline, acquiescence, and collaboration. Additionally, the use of hands-on activities may also require learning through a gamut of senses. Not only can the student use his/her eyes and ears during these activities, but most times, they can also use their senses of touch, smell, and taste, as well as intuition. Learning is, therefore, achieved using most or all the human senses. The combination of motivation/enthusiasm and the use of multiple senses creates an ideal environment conducive to leaming at a profound level.

  15. Joint federal initiative for demonstration of on-site innovative technologies

    International Nuclear Information System (INIS)

    Marsh, J.; Munro, J.F.; McKinnon, C.; Coyle, G.J.

    1994-01-01

    The Federal Government needs to develop and implement new technologies to support its environmental and waste management programs. The incentive is threefold: First, new technologies are needed to accomplish many cleanup and waste management tasks. Second, the development and implementation of new technologies is expected to reduce significantly total cleanup costs. Third, the development of new environmental technologies can help secure national economic advantages by making U.S. industry more competitive in terms of global environmental markets. The Federal Advisory Committee to Develop On-Site Innovative Technologies (DOIT) initiative reinvents inter-governmental relations by stressing the solving of environmental problems through partnerships rather than through confrontation. This overview -- which is essentially a shortened and slightly modified version of the recent Coordinating Group Report to the DOIT Committee --describes the waste management challenges facing the Nation, discusses the innovative solutions offered by DOIT, outlines progress of the initiative to date, and identifies critical next steps

  16. 75 FR 41895 - Whirlpool Corporation, Evansville Division, Including On-Site Leased Workers From Andrews...

    Science.gov (United States)

    2010-07-19

    ..., Evansville Division, Including On-Site Leased Workers From Andrews International, Inc., M.H. Equipment, and... 10321). The notice was amended on May 25, 2010 to include on-site leased workers from Andrews... workers of Whirlpool Corporation, Evansville Division, including on-site leased workers from Andrews...

  17. On-site and laboratory evaluations of soundscape quality in recreational urban spaces

    DEFF Research Database (Denmark)

    Bjerre, Lærke Cecilie; Larsen, Thea Mathilde; Sørensen, Anna Josefine

    2017-01-01

    on site. Moreover, the availability of the visual context in the listening experiment had no significant effect on the ratings. The participants were overall more positive toward natural sound sources on site. Conclusion: The full immersion in the on-site nonacoustic context may be important when...

  18. Optical technologies applied alongside on-site and remote approaches for climate gas emission quantification at a wastewater treatment plant

    DEFF Research Database (Denmark)

    Samuelsson, Jerker; Delre, Antonio; Tumlin, Susanne

    2018-01-01

    Plant-integrated and on-site gas emissions were quantified from a Swedish wastewater treatment plant by applying several optical analytical techniques and measurement methods. Plant-integrated CH4 emission rates, measured using mobile ground-based remote sensing methods, varied between 28.5 and 33.......5 kg CH4 h−1, corresponding to an average emission factor of 5.9% as kg CH4 (kg CH4production) −1, whereas N2O emissions varied between 4.0 and 6.4 kg h−1, corresponding to an average emission factor of 1.5% as kg N2O-N (kg TN influent) −1. Plant-integrated NH3 emissions were around 0.4 kg h−1...... quantifications were approximately two-thirds of the plant-integrated emission quantifications, which may be explained by the different timeframes of the approaches and that not all emission sources were identified during on-site investigation. Off-site gas emission quantifications, using ground-based remote...

  19. Flamanville 3 EPR, Safety Assessment and On-site Inspections

    International Nuclear Information System (INIS)

    Piedagnel, Corinne; Tarallo, Francois; Monnot, Bernard

    2011-01-01

    As a Technical Support Organisation of the French Safety Authority (ASN), the IRSN carries out the safety assessment of EPR project design and participates in the ASN inspections performed at the construction site and in factories. The design assessment consists in defining the safety functions which should be ensured by civil structures, evaluating the EPR Technical Code for Civil works (ETC-C) in which EdF has defined design criteria and construction rules, and carrying out a detailed assessment of a selection of safety-related structures. Those detailed assessments do not consist of a technical control but of an analysis whose objectives are to ensure that design and demonstrations are robust, in accordance with safety and regulatory rules. Most assessments led IRSN to ask EdF to provide additional justification sometimes involving significant modifications. In the light of those complementary justifications and modifications, IRSN concluded that assessments carried out on design studies were globally satisfactory. The participation of IRSN to the on-site inspections led by ASN is a part of the global control of the compliance of the reactor with its safety objectives. For that purpose IRSN has defined a methodology and an inspection program intended to ASN: based on safety functions associated with civil works (confinement and resistance to aggressions), the corresponding behaviour requirements are identified and linked to a list of main civil works elements. During the inspections, deviations to the project's technical specifications or to the rules of the art were pointed out by IRSN. Those deviations cover various items, such as concrete fabrication, concrete pouring methodology, lack of reinforcement in some structures, unadapted welding procedures of the containment leak-tight steel liner and unsatisfactory treatment of concreting joints. The analysis of those problems has revealed flaws in the organisation of the contractors teams together with an

  20. Cold climate performance analysis of on-site domestic wastewater treatment systems.

    Science.gov (United States)

    Williamson, Eric

    2010-06-01

    Household on-site septic systems with secondary wastewater treatment in Anchorage, Alaska, were sampled and analyzed for performance parameters during the winter to spring months. System types included intermittent dosing sand filters (ISF), three types of recirculating trickling filters (RTF), and suspended-growth aeration tanks. Total nitrogen from the trickling filter and aeration tank effluent was fairly uniform, at approximately 30 mg/L. Total suspended solids (TSS) means were mostly less than 15 mg/L. The 5-day biochemical oxygen demand (BODs) showed considerable variability, with means ranging from 9.2 mg/ L for ISFs up to 39.5 mg/L for one type of RTF, even though this type has shown excellent results in several test programs. The data suggested that effluent temperature within the sample range had almost no effect on effluent concentrations of BOD5 or TSS and only a small effect on the removal of total nitrogen. Non-climatic factors were probably of equal importance to treatment results.

  1. Industrial paramedics, out on site but not out of mind.

    Science.gov (United States)

    Acker, Joseph J; Johnston, Tania M; Lazarsfeld-Jensen, Ann

    2014-01-01

    (MOEMS). There is no single definition or comprehensive role description for industrial paramedic practice within the literature. Worldwide, there is little high-quality published evidence to adequately reflect all aspects of industrial paramedic practice. However, based on the literature available, this definition is offered: 'An industrial paramedic is an advanced clinical practitioner in paramedicine with an expanded scope of practice. The industrial paramedic provides emergency response, primary health care, chronic disease management, injury prevention, health promotion, medical referral, and repatriation coordination at remote mining sites, offshore installations, and other isolated industry settings. The industrial paramedic is resourceful, adaptable, and comfortable working independently. Industrial paramedics practice on site with limited resources, remotely located from tertiary care, and use telemedicine to consult with other health professionals as required. Industrial paramedics are experts at rapidly assessing, prioritising, and establishing control in their unpredictable workspace to reduce risks and create an environment conducive to quality patient care. The industrial paramedic preferably holds a specialised tertiary qualification and is committed to maintaining their clinical competency through continuing professional development.' Further research is required to validate, refute, or expand this proposed definition.

  2. Operating experience relating to on-site electric power sources. Proceedings of a Specialist Meeting

    International Nuclear Information System (INIS)

    1986-02-01

    The reliability of on-site electric power sources of nuclear power plants usually consisting of diesel generators, gas turbine generators and DC power sources, has been a matter of concern during reactor operations. The frequent recurrence and the important consequences of failures relating to on-site electric power sources have led to a general consensus that they form one of the most significant features influencing the total performance of the safety Systems. This has also been confirmed by surveys performed on the incidents reported through the NEA Incident Reporting System (IRS). Accordingly, a recommendation to organise a Specialist Meeting on the subject was made at the third annual meeting of CSNI Principal Working Group No. 1 (Operating Experience and Human Factors). At the 12. meeting of the CSNI held in November 1984. the Committee endorsed the proposal and accepted an offer by the United Kingdom to host and organise the Specialist Meeting. The Specialist Meeting, sponsored by the CSNI, was held in London, United Kingdom from 16 to 18 October 1985. It was hosted by H.M. Nuclear Installations Inspectorate of the Health and Safety Executive. The purpose of the meeting was to promote the exchange of Information on operating experience relating to on-site electric power sources and to look for measures to further improve their reliability In the areas of design, operation and licensing. The meeting was organised by a Programme Group which included nominated members of CSNI PWG No. 1. the Programme Group met in May and June 1985 in Paris to agree on the programme and practical arrangements for the meeting. As a result of the review of the abstracts which had been contributed in response to the Call for Papers, 28 papers were accepted for presentation during the meeting. Approximately 60 delegates from 13 Member countries, and the NEA Secretariat, attended the meeting. Session summaries prepared by the respective session chairmen are Included prior to the

  3. Operating experience relating to on-site electric power sources. Proceedings of a Specialist Meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-02-15

    The reliability of on-site electric power sources of nuclear power plants usually consisting of diesel generators, gas turbine generators and DC power sources, has been a matter of concern during reactor operations. The frequent recurrence and the important consequences of failures relating to on-site electric power sources have led to a general consensus that they form one of the most significant features influencing the total performance of the safety Systems. This has also been confirmed by surveys performed on the incidents reported through the NEA Incident Reporting System (IRS). Accordingly, a recommendation to organise a Specialist Meeting on the subject was made at the third annual meeting of CSNI Principal Working Group No. 1 (Operating Experience and Human Factors). At the 12. meeting of the CSNI held in November 1984. the Committee endorsed the proposal and accepted an offer by the United Kingdom to host and organise the Specialist Meeting. The Specialist Meeting, sponsored by the CSNI, was held in London, United Kingdom from 16 to 18 October 1985. It was hosted by H.M. Nuclear Installations Inspectorate of the Health and Safety Executive. The purpose of the meeting was to promote the exchange of Information on operating experience relating to on-site electric power sources and to look for measures to further improve their reliability In the areas of design, operation and licensing. The meeting was organised by a Programme Group which included nominated members of CSNI PWG No. 1. the Programme Group met in May and June 1985 in Paris to agree on the programme and practical arrangements for the meeting. As a result of the review of the abstracts which had been contributed in response to the Call for Papers, 28 papers were accepted for presentation during the meeting. Approximately 60 delegates from 13 Member countries, and the NEA Secretariat, attended the meeting. Session summaries prepared by the respective session chairmen are Included prior to the

  4. Exertional heat illness incidence and on-site medical team preparedness in warm weather.

    Science.gov (United States)

    Hosokawa, Yuri; Adams, William M; Belval, Luke N; Davis, Robert J; Huggins, Robert A; Jardine, John F; Katch, Rachel K; Stearns, Rebecca L; Casa, Douglas J

    2018-03-29

    To investigate the influence of estimated wet bulb globe temperature (WBGT) and the International Institute of Race Medicine (IIRM) activity modification guidelines on the incidence of exertional heat stroke (EHS) and heat exhaustion (HEx) and the ability of an on-site medical team to treat those afflicted. Medical records of EHS and HEx patients over a 17-year period from the New Balance Falmouth Road Race were examined. Climatologic data from nearby weather stations were obtained to calculate WBGT with the Australian Bureau of Meteorology (WBGT A ) and Liljegren (WBGT L ) models. Incidence rate (IR) of EHS, HEx, and combined total of EHS and HEx (COM) were calculated, and linear regression analyses were performed to assess the relationship between IR and WBGT A or WBGT L . One-way ANOVA was performed to compare differences in EHS, HEx, and COM incidence to four alert levels in the IIRM guidelines. Incidence of EHS, HEx, and COM was 2.12, 0.98, and 3.10 cases per 1000 finishers. WBGT A explained 48, 4, and 46% of the variance in EHS, HEx, and COM IR; WBGT L explained 63, 13, and 69% of the variance in EHS, HEx, and COM IR. Main effect of WBGT A and WBGT L on the alert levels were observed in EHS and COM IR (p < 0.05). The cumulative number of EHS patients treated did not exceed the number of cold water immersion tubs available to treat them. EHS IR increased as WBGT and IIRM alert level increased, indicating the need for appropriate risk mitigation strategies and on-site medical treatment.

  5. Exertional heat illness incidence and on-site medical team preparedness in warm weather

    Science.gov (United States)

    Hosokawa, Yuri; Adams, William M.; Belval, Luke N.; Davis, Robert J.; Huggins, Robert A.; Jardine, John F.; Katch, Rachel K.; Stearns, Rebecca L.; Casa, Douglas J.

    2018-03-01

    To investigate the influence of estimated wet bulb globe temperature (WBGT) and the International Institute of Race Medicine (IIRM) activity modification guidelines on the incidence of exertional heat stroke (EHS) and heat exhaustion (HEx) and the ability of an on-site medical team to treat those afflicted. Medical records of EHS and HEx patients over a 17-year period from the New Balance Falmouth Road Race were examined. Climatologic data from nearby weather stations were obtained to calculate WBGT with the Australian Bureau of Meteorology (WBGTA) and Liljegren (WBGTL) models. Incidence rate (IR) of EHS, HEx, and combined total of EHS and HEx (COM) were calculated, and linear regression analyses were performed to assess the relationship between IR and WBGTA or WBGTL. One-way ANOVA was performed to compare differences in EHS, HEx, and COM incidence to four alert levels in the IIRM guidelines. Incidence of EHS, HEx, and COM was 2.12, 0.98, and 3.10 cases per 1000 finishers. WBGTA explained 48, 4, and 46% of the variance in EHS, HEx, and COM IR; WBGTL explained 63, 13, and 69% of the variance in EHS, HEx, and COM IR. Main effect of WBGTA and WBGTL on the alert levels were observed in EHS and COM IR (p < 0.05). The cumulative number of EHS patients treated did not exceed the number of cold water immersion tubs available to treat them. EHS IR increased as WBGT and IIRM alert level increased, indicating the need for appropriate risk mitigation strategies and on-site medical treatment.

  6. On-site fuel cell field test support program

    Science.gov (United States)

    Staniunas, J. W.; Merten, G. P.

    1982-01-01

    In order to assess the impact of grid connection on the potential market for fuel cell service, applications studies were conducted to identify the fuel cell operating modes and corresponding fuel cell sizing criteria which offer the most potential for initial commercial service. The market for grid-connected fuel cell service was quantified using United's market analysis program and computerized building data base. Electric and gas consumption data for 268 buildings was added to our surveyed building data file, bringing the total to 407 buildings. These buildings were analyzed for grid-isolated and grid-connected fuel cell service. The results of the analyses indicated that the nursing home, restaurant and health club building sectors offer significant potential for fuel cell service.

  7. On-site detection of packaged squid freshness

    Science.gov (United States)

    Ahmad, Noor Azizah; Heng, Lee Yook; Salam, Faridah; Hanifah, Sharina Abu

    2018-04-01

    The development of indicator label for detection of total volatile basic nitrogen (TVB-N) is described. Dye extract from edible plants containing anthocyanins was immobilized onto iota-carrageenan as polymer matrix. TVB-N detection worked based on pH increase as the basic deterioration volatile amines generated in the package headspace. Results showed that the indicator label has changed color from blue to green after 12 hours of storage at ambient conditions. The TVB-N value was 38.9648 mg /100 g which is exceeded of acceptability level for seafood products. The pH value of squid flesh has also increased during storage. The colour values of L * and a * negative increases while b* negative decrease with increasing storage time. The indicator label is potentially used as freshness indicator for squid at ambient conditions.

  8. Effect of an integrated intervention package of preventive chemotherapy, community-led total sanitation and health education on the prevalence of helminth and intestinal protozoa infections in Côte d'Ivoire.

    Science.gov (United States)

    Hürlimann, Eveline; Silué, Kigbafori D; Zouzou, Fabien; Ouattara, Mamadou; Schmidlin, Thomas; Yapi, Richard B; Houngbedji, Clarisse A; Dongo, Kouassi; Kouadio, Bernadette A; Koné, Siaka; Bonfoh, Bassirou; N'Goran, Eliézer K; Utzinger, Jürg; Acka-Douabélé, Cinthia A; Raso, Giovanna

    2018-02-27

    Preventive chemotherapy with donated anthelminthic drugs is the cornerstone for the control of helminthiases. However, reinfection can occur rapidly in the absence of clean water and sanitation coupled with unhygienic behaviour. The purpose of this study was to assess the effect of an integrated package of interventions, consisting of preventive chemotherapy, community-led total sanitation (CLTS) and health education, on the prevalence of helminth and intestinal protozoa infections and on participants' knowledge, attitude, practice and beliefs (KAPB) towards these diseases including water, sanitation and hygiene (WASH). A cross-sectional survey was carried out in nine communities of south-central Côte d'Ivoire to assess people's infection with helminths and intestinal protozoa and KAPB. Subsequently, interventions were targeted to five communities, while the remaining communities served as control. The intervention encouraged latrine construction and an evaluation was done 6-7 months later to determine open defecation status of the respective communities. Anthelminthic treatment was provided to all community members. A follow-up cross-sectional survey was conducted approximately one year later, using the same procedures. Overall, 810 people had complete baseline and follow-up data and were given anthelminthic treatment. The baseline prevalence of hookworm, Schistosoma haematobium, Trichuris trichiura, Schistosoma mansoni and Ascaris lumbricoides was 31.1%, 7.0%, 2.0%, 1.0% and 0.3%, respectively. Four of the five intervention communities were classified open-defecation free. For hookworm infection, we observed higher negative changes in terms of proportion of decrease (-0.10; 95% confidence interval (CI): - 0.16, -0.04) and higher egg reduction rate (64.9 vs 15.2%) when comparing intervention with control communities. For intestinal protozoa, prevalence reduction was higher in intervention compared to control communities (8.2 vs 2.6%) and WASH indicators and

  9. Evaluation of Approaches for Managing Nitrate Loading from On-Site Wastewater Systems near La Pine, Oregon

    Science.gov (United States)

    Morgan, David S.; Hinkle, Stephen R.; Weick, Rodney J.

    2007-01-01

    .4 square miles) and study-area (247 square miles) scales to test the conceptual model and evaluate processes controlling nitrate concentrations in ground water and potential ground-water discharge of nitrate to streams. Simulation of water-quality conditions for a projected future build-out (base) scenario in which all existing lots are developed using conventional on-site wastewater systems indicates that, at equilibrium, average nitrate concentrations near the water table will exceed 10 mg N/L over areas totaling 9,400 acres. Other scenarios were simulated where future nitrate loading was reduced using advanced treatment on-site systems and a development transfer program. Seven other scenarios were simulated with total nitrate loading reductions ranging from 15 to 94 percent; simulated reductions in the area where average nitrate concentrations near the water table exceed 10 mg N/L range from 22 to 99 percent at equilibrium. Simulations also show that the ground-water system responds slowly to changes in nitrate loading due to low recharge rates and ground-water flow velocity. Consequently, reductions in nitrate loading will not immediately reduce average nitrate concentrations and the average concentration in the aquifer will continue to increase for 25-50 years depending on the level and timing of loading reduction. The capacity of the ground-water system to receive on-site wastewater system effluent, which is related to the density of homes, presence of upgradient residential development, ground-water recharge rate, ground-water flow velocity, and thickness of the oxic part of the aquifer, varies within the study area. Optimization capability was added to the study-area simulation model and the combined simulation-optimization model was used to evaluate alternative approaches to management of nitrate loading from on-site wastewater systems to the shallow alluvial aquifer. The Nitrate Loading Management Model (NLMM) was formulated to find the minimum red

  10. Single house on-site grey water treatment using a submerged membrane bioreactor for toilet flushing.

    Science.gov (United States)

    Fountoulakis, M S; Markakis, N; Petousi, I; Manios, T

    2016-05-01

    Wastewater recycling has been and continues to be practiced all over the world for a variety of reasons including: increasing water availability, combating water shortages and drought, and supporting environmental and public health protection. Nowadays, one of the most interesting issues for wastewater recycling is the on-site treatment and reuse of grey water. During this study the efficiency of a compact Submerged Membrane Bioreactor (SMBR) system to treat real grey water in a single house in Crete, Greece, was examined. In the study, grey water was collected from a bathtub, shower and washing machine containing significant amounts of organic matter and pathogens. Chemical oxygen demand (COD) removal in the system was approximately 87%. Total suspended solids (TSS) were reduced from 95mgL(-1) in the influent to 8mgL(-1) in the effluent. The efficiency of the system to reduce anionic surfactants was about 80%. Fecal and total coliforms decreased significantly using the SMBR system due to rejection, by the membrane, used in the study. Overall, the SMBR treatment produces average effluent values that would satisfy international guidelines for indoor reuse applications such as toilet flushing. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. On site experiments of the slanted soil treatment systems for domestic gray water.

    Science.gov (United States)

    Itayama, Tomoaki; Kiji, Masato; Suetsugu, Aya; Tanaka, Nobuyuki; Saito, Takeshi; Iwami, Norio; Mizuochi, Motoyuki; Inamori, Yuhei

    2006-01-01

    In order to make a breakthrough for the acute problem of water shortage in the world, the key words "decentralization and re-use" are very important for new sustainable sanitation systems that will be developed. Therefore, we focused on a new treatments system called "a slanted soil treatment system" which combines a biotoilet system with a domestic grey water treatment system. Because this system is a low cost and compact system, the system can be easily introduced to homes in urban areas or in the suburbs of cities in many developing countries. In this study, we performed on site experiments carried out on Shikoku Island, Japan, for several years. We obtained the following results. The slanted soil treatment system could remove organic pollutants and total nitrogen and total phosphorus in grey water effectively. Furthermore, the system performance became high in the case of the high concentration of the influent water. The nitrification reaction and denitrification reaction were speculated to exist due to aerobic zones and anaerobic zones present in the slanted soil treatment system. The slanted soil treatment system could perform for approximately 3 years with zero maintenance. The plug flow model of 1st order reaction kinetics could describe the reaction in the slanted soil treatment system. However, it is necessary to improve the system to maintain the performance in all seasons.

  12. Advances in speed and performance of on-site bioremediation

    International Nuclear Information System (INIS)

    Shearon, M.S.; Autry, A.R.; Archer, B.

    1991-01-01

    SafeSoil is a proprietary additive and ex-situ treatment process which mediates and enhances biodegradation of environmental pollutants. The additive itself contains natural surfactants, organic and inorganic nutrients, and enzymes (primarily oxygenases). The treatment is an ex-situ process involving excavation and stockpiling of contaminated soil, mixing of the excavated soil with the authors proprietary additive in a mixer, and then the placement of the treated soil in curing piles, during which time biodegradation is actively occurring. SafeSoil was proven effective at treating approximately 35,000 cubic yards of soil contaminated with gasoline, diesel fuel, kerosene, motor oil, and transmission fluid to below specified action levels (50 ppm for TFH, and five ppm for total BTEX) in a full-scale remedial action for the channel Gateway Development project at Marina del Rey, California, within 15 days for 70 to 75% of the soil mass treated. More time was required for successful bioremediation of some of the more recalcitrant (persistent) contaminants, principally longer chain aliphatic hydrocarbons

  13. A proposal on siting counterplan of nuclear power plants

    International Nuclear Information System (INIS)

    Sasao, Hitoshi

    1980-01-01

    As for the nuclear power generation in Japan. 21 plants with 14.95 million kW capacity have started the operation in 14 years. It is equivalent to more than 12% of the total capacity of power stations. But the environment around the development of nuclear power generation becomes more and more strict recently, and the formation of the consensus of residents becomes a very large political problem. The lead time from the proposal of construction to the local community to the commencement of operation was 8 years and 1 month in the case of 10 nuclear power stations in operation, but it is extended to 15 years and 6 months in the case of 4 power stations under construction. The prefectures where nuclear power stations are located were seven at the end of 1970, and only three were added during 9 years thereafter. It shows the difficulty of the location of nuclear power stations in new prefectures. In order to attain 78 million kW of nuclear power generation by 1995, the location of 50 million kW must be decided in coming several years in view of the lead time. The progress of the studies in the Atomic Industrial Forum, the strengthening of security system in the sistricts concerned, the formation of open environment for informations, the improvement of the setup concerning the compensation to fishery and others, and the studies on the law concerning the special measures for the districts where nuclear facilities are located are discussed. (Kako, I.)

  14. 77 FR 13352 - Exxonmobil Chemical Company Films Business Division Including on-Site Leased Workers From...

    Science.gov (United States)

    2012-03-06

    ..., Take Care Corporation, Conestoga Rovers and Associates, Phillips Engineering, Rockwell Engineering, Excel Logistics, and American Food and Vending, Calhoun Spotting Service, and Job World working on-site...

  15. Stretchable Tattoo-Like Heater with On-Site Temperature Feedback Control

    Directory of Open Access Journals (Sweden)

    Andrew Stier

    2018-04-01

    Full Text Available Wearable tissue heaters can play many important roles in the medical field. They may be used for heat therapy, perioperative warming and controlled transdermal drug delivery, among other applications. State-of-the-art heaters are too bulky, rigid, or difficult to control to be able to maintain long-term wearability and safety. Recently, there has been progress in the development of stretchable heaters that may be attached directly to the skin surface, but they often use expensive materials or processes and take significant time to fabricate. Moreover, they lack continuously active, on-site, unobstructive temperature feedback control, which is critical for accommodating the dynamic temperatures required for most medical applications. We have developed, fabricated and tested a cost-effective, large area, ultra-thin and ultra-soft tattoo-like heater that has autonomous proportional-integral-derivative (PID temperature control. The device comprises a stretchable aluminum heater and a stretchable gold resistance temperature detector (RTD on a soft medical tape as fabricated using the cost and time effective “cut-and-paste” method. It can be noninvasively laminated onto human skin and can follow skin deformation during flexure without imposing any constraint. We demonstrate the device’s ability to maintain a target temperature typical of medical uses over extended durations of time and to accurately adjust to a new set point in process. The cost of the device is low enough to justify disposable use.

  16. An accurate on-site calibration system for electronic voltage transformers using a standard capacitor

    Science.gov (United States)

    Hu, Chen; Chen, Mian-zhou; Li, Hong-bin; Zhang, Zhu; Jiao, Yang; Shao, Haiming

    2018-05-01

    Ordinarily electronic voltage transformers (EVTs) are calibrated off-line and the calibration procedure requires complex switching operations, which will influence the reliability of the power grid and induce large economic losses. To overcome this problem, this paper investigates a 110 kV on-site calibration system for EVTs, including a standard channel, a calibrated channel and a PC equipped with the LabView environment. The standard channel employs a standard capacitor and an analogue integrating circuit to reconstruct the primary voltage signal. Moreover, an adaptive full-phase discrete Fourier transform (DFT) algorithm is proposed to extract electrical parameters. The algorithm involves the process of extracting the frequency of the grid, adjusting the operation points, and calculating the results using DFT. In addition, an insulated automatic lifting device is designed to realize the live connection of the standard capacitor, which is driven by a wireless remote controller. A performance test of the capacitor verifies the accurateness of the standard capacitor. A system calibration test shows that the system ratio error is less than 0.04% and the phase error is below 2‧, which meets the requirement of the 0.2 accuracy class. Finally, the developed calibration system was used in a substation, and the field test data validates the availability of the system.

  17. The use of modern on-site bioremediation systems to reduce crude oil contamination on oilfield properties

    International Nuclear Information System (INIS)

    Hildebrandt, W.W.; Wilson, S.B.

    1991-01-01

    Oil-field properties frequently have areas in which the soil has been degraded with crude oil. Soil contaminated in this manner is often considered either a hazardous waste or designated waste under regulatory guidelines. As a result, there is often concern about an owner's liabilities and the financial institution's liabilities whenever oilfield properties are transferred to new operators, abandoned, or converted to other uses such as real estate. There is also concern about the methods and relative costs to remediate soil which has been contaminated with crude oil. Modern, well-designed, soil bioremediation systems are cost effective for the treatment of crude oil contamination, and these systems can eliminate an owner's subsequent liabilities. Compared to traditional land-farming practices, a modern on-site bioremediation system (1) requires significantly less surface area, (2) results in lower operating costs, and (3) provides more expeditious results. Compared to excavation and off-site disposal of the contaminated soil, on-site bioremediation will eliminate subsequent liabilities and is typically more cost effective. Case studies indicate that o-site bioremediation systems have been successful at reducing the crude oil contamination in soil to levels which are acceptable to regulatory agencies in less than 10 weeks. Total costs for on-site bioremediation has ranged from $35 to $40 per cubic yard of treated soil, including excavation

  18. Studies on site characterization methodologies for high level radioactive waste disposal

    International Nuclear Information System (INIS)

    Wang Ju; Guo Yonghai; Chen Weiming

    2008-01-01

    This paper presents the final achievement of the project 'Studies of Site-specific Geological Environment for High Level Waste Disposal and Performance Assessment Methodology, Part Ⅰ: Studies on Site Characterization Methodologies for High Level Radioactive Waste Disposal', which is a 'Key Scientific and Technological Pre-Research Project for National Defense' during 2001-2005. The study area is Beishan area, Gansu Province, NW China--the most potential site for China's underground research laboratory and high level radioactive waste repository. The boreholes BS01, BS2, BS03 and BS04 drilled in fractured granite media in Beishan are used to conduct comprehensive studies on site characterization methodologies, including: bore hole drilling method, in situ measurement methods of hydrogeological parameters, underground water sampling technology, hydrogeochemical logging method, geo-stress measurement method, acoustic borehole televiewer measurement method, borehole radar measurement method, fault stability evaluation methods and rock joint evaluation method. The execution of the project has resulted in the establishment of an 'Integrated Methodological System for Site Characterization in Granite Site for High Level Radioactive Waste Repository' and the 8 key methodologies for site characterization: bore hole drilling method with minimum disturbance to rock mass, measurement method for hydrogeological parameters of fracture granite mass, in situ groundwater sampling methods from bore holes in fractured granite mass, fracture measurement methods by borehole televiewer and bore radar system, hydrogeochemical logging, low permeability measurement methods, geophysical methods for rock mass evaluation, modeling methods for rock joints. Those methods are comprehensive, advanced, innovative, practical, reliable and of high accuracy. The comprehensive utilization of those methods in granite mass will help to obtain systematic parameters of

  19. 13 CFR 120.1051 - Frequency of on-site reviews and examinations.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Frequency of on-site reviews and examinations. 120.1051 Section 120.1051 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Risk-Based Lender Oversight Supervision § 120.1051 Frequency of on-site reviews and examinations...

  20. 13 CFR 120.1050 - On-site reviews and examinations.

    Science.gov (United States)

    2010-01-01

    ... losses); (3) Management quality (including internal controls, loan portfolio management, and asset... Risk-Based Lender Oversight Supervision § 120.1050 On-site reviews and examinations. (a) On-site... operations management; (3) Credit administration; and (4) Compliance with Loan Program Requirements. (b) On...

  1. 78 FR 28642 - Eastman Kodak Company, Electrographic Print Solutions, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-05-15

    ... Kodak Company, Electrographic Print Solutions, Including On-Site Leased Workers From Adecco and Datrose, Spencerport, New York; Eastman Kodak Company, IPS, Including On-Site Leased Workers From Adecco, Dayton, Ohio... Trade Adjustment Assistance (TAA) filed on behalf of Eastman Kodak Company, Electrographic Print...

  2. 78 FR 19530 - Eastman Kodak Company (GCG), Electrographic Print Solutions, Including On-Site Leased Workers...

    Science.gov (United States)

    2013-04-01

    ... Kodak Company (GCG), Electrographic Print Solutions, Including On-Site Leased Workers From Adecco and Datrose, Spencerport, New York; Eastman Kodak Company, IPS, Including On-Site Leased Workers From Adecco..., 2011, applicable to workers of Eastman Kodak Company (GCG), Electrographic Print Solutions, including...

  3. 78 FR 12358 - UBS Financial Services, Inc., Wealth Management Americas Operations, Including On-Site Leased...

    Science.gov (United States)

    2013-02-22

    ..., Inc., Wealth Management Americas Operations, Including On-Site Leased Workers From Leafstone... Services, Inc., Wealth Management Americas Operations (UBS), Weehawken, New Jersey. The workers are engaged... to include all leased workers on-site at UBS Financial Services, Inc., Wealth Management Americas...

  4. 78 FR 48468 - Delphi Corporation, Electronics and Safety Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-08-08

    ..., Electronics and Safety Division, Including On-Site Leased Workers From Securitas, Bartech, Flint Janitorial... Adjustment Assistance on May 20, 2013, applicable to workers of Delphi Corporation, Electronics and Safety... on- site at the Flint, Michigan location of Delphi Corporation, Electronics and Safety Division. The...

  5. 75 FR 62423 - Barnstead Thermolyne Corporation, a Subsidiary of Thermo Fisher Scientific, Including On-Site...

    Science.gov (United States)

    2010-10-08

    ... related to the production of scientific laboratory equipment. New information shows that workers leased... Corporation, a Subsidiary of Thermo Fisher Scientific, Including On-Site Leased Workers From Sedona Staffing... Scientific, including on- site leased workers from Sedona Staffing, Dubuque, Iowa. The notice was published...

  6. 75 FR 32221 - Whirlpool Corporation, Evansville Division, Including On-Site Leased Workers from Andrews...

    Science.gov (United States)

    2010-06-07

    ..., Evansville Division, Including On-Site Leased Workers from Andrews International, Inc., Evansville, IN... that workers leased from Andrews International, Inc. were employed on-site at the Evansville, Indiana... findings, the Department is amending this certification to include leased workers from Andrews...

  7. 77 FR 4368 - Abbott Laboratories, Diagnostics Division, Including On-Site Leased Workers From Manpower...

    Science.gov (United States)

    2012-01-27

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,201] Abbott Laboratories..., applicable to workers of Abbott Laboratories, Diagnostics Division, including on-site leased workers from... (clerical) were employed on-site at the Irving, Texas location of Abbott Laboratories, Diagnostics Division...

  8. 75 FR 28295 - Cummins Filtration, Including On-Site Leased Workers From Manpower and Spherion Staffing...

    Science.gov (United States)

    2010-05-20

    .... The Department has determined that workers from Spherion Staffing were sufficiently under the control..., Including On-Site Leased Workers From Manpower and Spherion Staffing, Including On-Site Workers From Hagemeyer North America, Lake Mills, IA; Amended Certification Regarding Eligibility To Apply for Worker...

  9. 76 FR 81986 - Honeywell International, Inc., Automation and Control Solutions Division, Including On-Site...

    Science.gov (United States)

    2011-12-29

    ..., Inc., Automation and Control Solutions Division, Including On-Site Leased Workers From Manpower...., Automation and Control Solutions Division. The Department has determined that these workers were sufficiently...., Automation and Control Solutions Division, including on-site leased workers from Manpower, Spherion...

  10. 76 FR 175 - Faurecia Emissions Control Technologies Including On-Site Leased Workers From Adecco Employment...

    Science.gov (United States)

    2011-01-03

    ... Technologies Including On-Site Leased Workers From Adecco Employment Servcies and Emcon Technologies, Troy, MI..., applicable to workers of Faurecia Emissions Control Technologies, Troy, Michigan, including on-site leased workers from Adecco Employment Services, Troy, Michigan. The Department's notice of determination was...

  11. The extent of on-site leakage in selected suburbs of Johannesburg ...

    African Journals Online (AJOL)

    This study investigated on-site leakage on 182 properties with relatively new municipal water meters in well-established suburbs of Johannesburg. A methodology was developed to estimate the on-site leakage rate from readings taken from these municipal water meters, which was then adjusted to account for metering ...

  12. Assessment of On-Site Treatment Process of Institutional Building’s Wastewater

    Directory of Open Access Journals (Sweden)

    Motasem N. Saidan

    2018-03-01

    Full Text Available This study is conducted to investigate the characteristics of outflow wastewater of the 1 m3 on-site wastewater treatment unit on the basis of the testing and measurement data of the samples that were taken during the study monitored period (August 2017 to January 2018. For this purpose, samples were taken on a weekly basis from the treated wastewater effluent and five quality parameters (biochemical oxygen demand (BOD, chemical oxygen demand (COD, total suspended solids (TSS, pH, E-coli counts were monitored and measured. The average values of the five parameters were compared with the Jordanian standard maximum values, and water reuse in irrigation of plants classifications have been assessed and investigated. Average values of BOD, COD, TSS, pH, and E-coli in treated wastewater were 11 mg/L, 104 mg/L, 15 mg/L, 7.51, and 387 counts, respectively. The installation of in-line ultraviolet (UV unit in recirculating delivery system played a vital role in the reduction of counts far below the permissible maximum level (1000 counts. Based on national and international standards and criteria, results showed that the treated wastewater is suitable for the irrigation of two classifications of plants: (i Fruit trees, road-green sides outside cities, and green landscape; (ii Crops, commercial crops, and forest trees. Hence, such very low water flow rate treatment system can be utilized in refugees’ camps and water scarce residential areas in Jordan.

  13. Nitrogen and carbon dynamics beneath on-site wastewater treatment systems in Pitt County, North Carolina.

    Science.gov (United States)

    Del Rosario, Katie L; Humphrey, Charles P; Mitra, Siddhartha; O'Driscoll, Michael A

    2014-01-01

    On-site wastewater treatment systems (OWS) are a potentially significant non-point source of nutrients to groundwater and surface waters, and are extensively used in coastal North Carolina. The goal of this study was to determine the treatment efficiency of four OWS in reducing total dissolved nitrogen (TDN) and dissolved organic carbon (DOC) concentrations before discharge to groundwater and/or adjacent surface water. Piezometers were installed for groundwater sample collection and nutrient analysis at four separate residences that use OWS. Septic tank effluent, groundwater, and surface water samples (from an adjacent stream) were collected four times during 2012 for TDN and DOC analysis and pH, temperature, electrical conductivity, and dissolved oxygen measurements. Treatment efficiencies from the tank to the groundwater beneath the drainfields ranged from 33 to 95% for TDN and 45 to 82% for DOC, although dilution accounted for most of the concentration reductions. There was a significant positive correlation between nitrate concentration and separation distance from trench bottom to water table and a significant negative correlation between DOC concentration and separation distance. The TDN and DOC transport (>15 m) from two OWS with groundwater saturated drainfield trenches was significant.

  14. Engineered ecosystem for on-site wastewater treatment in tropical areas.

    Science.gov (United States)

    de Sá Salomão, André Luis; Marques, Marcia; Severo, Raul Gonçalves; da Cruz Roque, Odir Clécio

    2012-01-01

    There is a worldwide demand for decentralized wastewater treatment options. An on-site engineered ecosystem (EE) treatment plant was designed with a multistage approach for small wastewater generators in tropical areas. The array of treatment units included a septic tank, a submersed aerated filter, and a secondary decanter followed by three vegetated tanks containing aquatic macrophytes intercalated with one tank of algae. During 11 months of operation with a flow rate of 52 L h(-1), the system removed on average 93.2% and 92.9% of the chemical oxygen demand (COD) and volatile suspended solids (VSS) reaching final concentrations of 36.3 ± 12.7 and 13.7 ± 4.2 mg L(-1), respectively. Regarding ammonia-N (NH(4)-N) and total phosphorus (TP), the system removed on average 69.8% and 54.5% with final concentrations of 18.8 ± 9.3 and 14.0 ± 2.5 mg L(-1), respectively. The tanks with algae and macrophytes together contributed to the overall nutrient removal with 33.6% for NH(4)-N and 26.4% for TP. The final concentrations for all parameters except TP met the discharge threshold limits established by Brazilian and EU legislation. The EE was considered appropriate for the purpose for which it was created.

  15. BIPM direct on-site Josephson voltage standard comparisons: 20 years of results

    International Nuclear Information System (INIS)

    Solve, Stephane; Stock, Michael

    2012-01-01

    The discovery of the Josephson effect has for the first time given national metrology institutes (NMIs) the possibility of maintaining voltage references which are stable in time. In addition, the introduction in 1990 of a conventional value for the Josephson constant, K J-90 , has greatly improved world-wide consistency among representations of the volt. For 20 years, the Bureau International des Poids et Mesures (BIPM) has conducted an ongoing, direct, on-site key comparison of Josephson voltage standards among NMIs under the denominations BIPM.EM-K10.a (1 V) and BIPM.EM-K10.b (10 V) in the framework of the mutual recognition arrangement (CIPM MRA). The results of 41 comparisons illustrate the consistency among primary voltage standards and have demonstrated that a relative total uncertainty of a few parts in 10 10 is achievable if a few precautions are taken with regard to the measurement set-up. Of particular importance are the grounding, efficient filters and high insulation resistance of the measurement leads, and clean microwave distribution along the propagation line to the Josephson array. This paper reviews the comparison scheme and technical issues that need to be taken into account to achieve a relative uncertainty at the level of a few parts in 10 10 or even a few parts in 10 11 in the best cases. (paper)

  16. [On-site evaluation of raw milk qualities by portable Vis/NIR transmittance technique].

    Science.gov (United States)

    Wang, Jia-Hua; Zhang, Xiao-Wei; Wang, Jun; Han, Dong-Hai

    2014-10-01

    To ensure the material safety of dairy products, visible (Vis)/near infrared (NIR) spectroscopy combined with che- mometrics methods was used to develop models for fat, protein, dry matter (DM) and lactose on-site evaluation. A total of 88 raw milk samples were collected from individual livestocks in different years. The spectral of raw milk were measured by a porta- ble Vis/NIR spectrometer with diffused transmittance accessory. To remove the scatter effect and baseline drift, the diffused transmittance spectra were preprocessed by 2nd order derivative with Savitsky-Golay (polynomial order 2, data point 25). Changeable size moving window partial least squares (CSMWPLS) and genetic algorithms partial least squares (GAPLS) meth- ods were suggested to select informative regions for PLS calibration. The PLS and multiple linear regression (MLR) methods were used to develop models for predicting quality index of raw milk. The prediction performance of CSMWPLS models were similar to GAPLS models for fat, protein, DM and lactose evaluation, the root mean standard errors of prediction (RMSEP) were 0.115 6/0.103 3, 0.096 2/0.113 7, 0.201 3/0.123 7 and 0.077 4/0.066 8, and the relative standard deviations of prediction (RPD) were 8.99/10.06, 3.53/2.99, 5.76/9.38 and 1.81/2.10, respectively. Meanwhile, the MLR models were also cal- ibrated with 8, 10, 9 and 7 variables for fat, protein, DM and lactose, respectively. The prediction performance of MLR models was better than or close to PLS models. The MLR models to predict fat, protein, DM and lactose yielded the RMSEP of 0.107 0, 0.093 0, 0.136 0 and 0.065 8, and the RPD of 9.72, 3.66, 8.53 and 2.13, respectively. The results demonstrated the usefulness of Vis/NIR spectra combined with multivariate calibration methods as an objective and rapid method for the quality evaluation of complicated raw milks. And the results obtained also highlight the potential of portable Vis/NIR instruments for on-site assessing quality indexes of

  17. On-Site Fecal Sludge Treatment with the Anaerobic Digestion Pasteurization Latrine.

    Science.gov (United States)

    Forbis-Stokes, Aaron A; O'Meara, Patrick F; Mugo, Wangare; Simiyu, Gelas M; Deshusses, Marc A

    2016-11-01

    The Anaerobic Digestion Pasteurization Latrine (ADPL) is a self-contained and energy neutral on-site sanitation system using anaerobic digestion of fecal sludge to generate biogas and then uses the biogas to pasteurize the digester effluent at 65-75°C to produce a safe effluent that can be reused locally as a fertilizer. Two ADPL systems were installed on residential plots with 17 and 35 residents in a peri-urban area outside of Eldoret, Kenya. Each system comprised three toilets built above a floating dome digester and one heat pasteurization system to sanitize the digested effluent. ADPLs are simple systems, with no moving parts and relying on gravity-induced flows. Adoption at the two sites was successful, and residents reported that the systems had little to no odor or flies. ADPLs were monitored for biogas production and temperatures in the pasteurization system. ADPLs serving 17 and 35 residents produced on average 16 and 11 L biogas /person/day (maximum of 20 and 15 L biogas /p/d), respectively. The temperature in the sterilization system was greater than 65°C on 58% and 87% of sampling days during the most stable period of operation. Treated effluent was analyzed periodically for chemical oxygen demand (COD), biochemical oxygen demand (BOD), total ammonia nitrogen (TAN), pH, and fecal coliform (FC). On average, the effluent at the two locations contained 4,540 and 6,450 mg COD/L (an 85% or 89% reduction of the estimated input), 2,050 and 3,970 mg BOD/L, and 2,420 and 4,760 mg NH 3 -N, respectively, and greater than 5 log reductions of FC (nondetectable) in the sterilization tank. Results from this field study show that anaerobic digestion of minimally diluted fecal sludge can provide enough energy to pasteurize digester effluent and that the ADPL may be a suitable option for on-site fecal sludge treatment.

  18. On-Site Fecal Sludge Treatment with the Anaerobic Digestion Pasteurization Latrine

    Science.gov (United States)

    Forbis-Stokes, Aaron A.; O'Meara, Patrick F.; Mugo, Wangare; Simiyu, Gelas M.; Deshusses, Marc A.

    2016-01-01

    Abstract The Anaerobic Digestion Pasteurization Latrine (ADPL) is a self-contained and energy neutral on-site sanitation system using anaerobic digestion of fecal sludge to generate biogas and then uses the biogas to pasteurize the digester effluent at 65–75°C to produce a safe effluent that can be reused locally as a fertilizer. Two ADPL systems were installed on residential plots with 17 and 35 residents in a peri-urban area outside of Eldoret, Kenya. Each system comprised three toilets built above a floating dome digester and one heat pasteurization system to sanitize the digested effluent. ADPLs are simple systems, with no moving parts and relying on gravity-induced flows. Adoption at the two sites was successful, and residents reported that the systems had little to no odor or flies. ADPLs were monitored for biogas production and temperatures in the pasteurization system. ADPLs serving 17 and 35 residents produced on average 16 and 11 Lbiogas/person/day (maximum of 20 and 15 Lbiogas/p/d), respectively. The temperature in the sterilization system was greater than 65°C on 58% and 87% of sampling days during the most stable period of operation. Treated effluent was analyzed periodically for chemical oxygen demand (COD), biochemical oxygen demand (BOD), total ammonia nitrogen (TAN), pH, and fecal coliform (FC). On average, the effluent at the two locations contained 4,540 and 6,450 mg COD/L (an 85% or 89% reduction of the estimated input), 2,050 and 3,970 mg BOD/L, and 2,420 and 4,760 mg NH3-N, respectively, and greater than 5 log reductions of FC (nondetectable) in the sterilization tank. Results from this field study show that anaerobic digestion of minimally diluted fecal sludge can provide enough energy to pasteurize digester effluent and that the ADPL may be a suitable option for on-site fecal sludge treatment. PMID:27924135

  19. On-Site Detection as a Countermeasure to Chemical Warfare/Terrorism.

    Science.gov (United States)

    Seto, Y

    2014-01-01

    On-site monitoring and detection are necessary in the crisis and consequence management of wars and terrorism involving chemical warfare agents (CWAs) such as sarin. The analytical performance required for on-site detection is mainly determined by the fatal vapor concentration and volatility of the CWAs involved. The analytical performance for presently available on-site technologies and commercially available on-site equipment for detecting CWAs interpreted and compared in this review include: classical manual methods, photometric methods, ion mobile spectrometry, vibrational spectrometry, gas chromatography, mass spectrometry, sensors, and other methods. Some of the data evaluated were obtained from our experiments using authentic CWAs. We concluded that (a) no technologies perfectly fulfill all of the on-site detection requirements and (b) adequate on-site detection requires (i) a combination of the monitoring-tape method and ion-mobility spectrometry for point detection and (ii) a combination of the monitoring-tape method, atmospheric pressure chemical ionization mass spectrometry with counterflow introduction, and gas chromatography with a trap and special detectors for continuous monitoring. The basic properties of CWAs, the concept of on-site detection, and the sarin gas attacks in Japan as well as the forensic investigations thereof, are also explicated in this article. Copyright © 2014 Central Police University.

  20. Phonon transmission and thermal conductance in one-dimensional system with on-site potential disorder

    International Nuclear Information System (INIS)

    Ma Songshan; Xu Hui; Deng Honggui; Yang Bingchu

    2011-01-01

    The role of on-site potential disorder on phonon transmission and thermal conductance of one-dimensional system is investigated. We found that the on-site potential disorder can lead to the localization of phonons, and has great effect on the phonon transmission and thermal conductance of the system. As on-site potential disorder W increases, the transmission coefficients decrease, and approach zero at the band edges. Corresponding, the thermal conductance decreases drastically, and the curves for thermal conductance exhibit a series of steps and plateaus. Meanwhile, when the on-site potential disorder W is strong enough, the thermal conductance decreases dramatically with the increase of system size N. We also found that the efficiency of reducing thermal conductance by increasing the on-site potential disorder strength is much better than that by increasing the on-site potential's amplitude. - Highlights: → We studied the effect of on-site potential disorder on thermal transport. → Increasing disorder will decrease thermal transport. → Increasing system size will also decrease its thermal conductance. → Increasing disorder is more efficient than other in reducing thermal conductance.

  1. Do On-Site Mental Health Professionals Change Pediatricians' Responses to Children's Mental Health Problems?

    Science.gov (United States)

    McCue Horwitz, Sarah; Storfer-Isser, Amy; Kerker, Bonnie D; Szilagyi, Moira; Garner, Andrew S; O'Connor, Karen G; Hoagwood, Kimberly E; Green, Cori M; Foy, Jane M; Stein, Ruth E K

    2016-01-01

    To assess the availability of on-site mental health professionals (MHPs) in primary care; to examine practice/pediatrician characteristics associated with on-site MHPs; and to determine whether the presence of on-site MHPs is related to pediatricians' comanaging or more frequently identifying, treating/managing, or referring mental health (MH) problems. Analyses included American Academy of Pediatrics (AAP) members who participated in an AAP Periodic Survey in 2013 and who practiced general pediatrics (n = 321). Measures included sociodemographics, practice characteristics, questions about on-site MHPs, comanagement of MH problems, and pediatricians' behaviors in response to 5 prevalent MH problems. Weighted univariate, bivariate, and multivariable analyses were performed. Thirty-five percent reported on-site MHPs. Practice characteristics (medical schools, universities, health maintenance organizations, managed, or referred 5 common child MH problems. Among the subset of pediatricians who reported comanaging, there was an association with comanagement when the on-site MHP was a child psychiatrist, substance abuse counselor, or social worker. On-site MHPs are more frequent in settings where low-income children are served and where pediatricians train. Pediatricians who comanage MH problems are more likely to do so when the on-site MHP is a child psychiatrist, substance abuse counselor, or social worker. Overall, on-site MHPs were not associated with comanagement or increased likelihood of pediatricians identifying, treating/managing, or referring children with 5 common child MH problems. Copyright © 2016 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  2. Proposal for the award of a contract for provision of on-site welding inspections for the LHC

    CERN Document Server

    European Organization for Nuclear Research

    2004-01-01

    This document concerns the award of a contract for the provision of on-site welding inspections for the LHC magnets and their interconnections. Following a market survey MS-3207/TIS carried out among 82 firms in twelve Member States, a call for tenders (IT-3276/AT/LHC) was sent on 27 January 2004 to twelve firms, in seven Member States. By the closing date, CERN had received five tenders from four firms and one consortium in three Member States. The Finance Committee is invited to agree to the negotiation of a contract with IS SERVICES (FR), the lowest bidder for the provision of on-site welding inspections for the LHC for a total amount not exceeding 710 197 euros (1 121 543 Swiss francs) covering a period of three years starting on 1 July 2004 with an option for additional work for an amount of 89 677 euros (141 619 Swiss francs) bringing the total amount to 799 874 euros (1 263 162 Swiss francs) not subject to revision. The rate of exchange used is that stipulated in the tender. The firm has indicated the ...

  3. [Analysis on on-site rescue and traumatic features of victims involved in gas explosion accident in Hangzhou].

    Science.gov (United States)

    Wang, X G; Jin, R H; Liu, F P; Han, C M

    2017-10-20

    Objective: To investigate the situations of on-site rescue and traumatic features of victims involved in gas explosion accident in Hangzhou, so as to provide more data support for emergency medical rescues of the similar incidents of massive casualty. Methods: Two medical workers with a certain clinical experience were sent to Hangzhou 120 emergency medical centers to collect data of the on-site rescue on 21st July, 2017, including ambulance call-outs, on-site command and traffic conditions, and on-site triage and evacuation of the victims. They were then sent to the hospitals receiving the victims to investigate the situations of these victims including the general information (such as gender, age, admitted hospitals, and number of admission, discharge, and transferring in the first two weeks after the accident) and injury assessment [such as injury position and type, injury severity evaluation by New Injury Severity Scoring (NISS), and burn severity evaluation for victims with burns]. Results: (1) A total of 15 ambulances reached the accident site for rescue. The traffic and transportation were jammed and interrupted after this accident. On-site triage and distribution were disorderly conducted. (2) Clinical data of 53 victims were collected, including 24 males and 29 females, with the age of 8 to 70 (34±14) years old. They were sent into 6 hospitals in Hangzhou. Two victims died on the day of accident. Up to two weeks after this accident, 28 (52.8%) victims were discharged from the hospitals and received follow-up in outpatient department. Five victims with severe injuries were transferred to the other hospitals. (3) Based on the results of NISS, the injury severities were mild in 29 (54.7%) cases, moderate in 9 (17.0%) cases, serious in 3 (5.7%) cases, and severe in 12 (22.6%) cases. Those 2 dead victims were classified into the severe category due to the highest NISS score of 75. For all of the victims, skin and soft tissue defects were most common. Six (11

  4. Development of the on-site power supply in German nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Simon, M. [Gesellschaft fuer Reaktorsicherheit - GRS mbH, Schwertnergasse 1, D-5000 Koeln 1, Cologne (Germany)

    1986-02-15

    The design of the on-site power supply is different in German Nuclear Power Plants, depending on age and size of the plant. The cause for this is the evolution of the safety requirements. The general development of the design of safety Systems, which resulted in a strict separation of redundant trains is also reflected in the design of the emergency power system and even the complete on-site power supply System. This will be demonstrated by different examples. The advantages of this design with respect to the availability of on-site power will be explained and verified by means of operating experience. (author)

  5. Total parenteral nutrition - infants

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007239.htm Total parenteral nutrition - infants To use the sharing features on this page, please enable JavaScript. Total parenteral nutrition (TPN) is a method of feeding that bypasses ...

  6. Total parenteral nutrition

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000177.htm Total parenteral nutrition To use the sharing features on this page, please enable JavaScript. Total parenteral nutrition (TPN) is a method of feeding that bypasses ...

  7. Technique of total thyroidectomy

    International Nuclear Information System (INIS)

    Rao, R.S.

    1999-01-01

    It is essential to define the various surgical procedures that are carried out for carcinoma of the thyroid gland. They are thyroid gland, subtotal lobectomy, total thyroidectomy and near total thyroidectomy

  8. Total iron binding capacity

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003489.htm Total iron binding capacity To use the sharing features on this page, please enable JavaScript. Total iron binding capacity (TIBC) is a blood test to ...

  9. Total well dominated trees

    DEFF Research Database (Denmark)

    Finbow, Arthur; Frendrup, Allan; Vestergaard, Preben D.

    cardinality then G is a total well dominated graph. In this paper we study composition and decomposition of total well dominated trees. By a reversible process we prove that any total well dominated tree can both be reduced to and constructed from a family of three small trees....

  10. Comparison of conventional vs. modular hydrogen refueling stations and on-site production vs. delivery.

    Energy Technology Data Exchange (ETDEWEB)

    Hecht, Ethan S. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Pratt, Joseph William [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2017-03-01

    To meet the needs of public and private stakeholders involved in the development, construction, and operation of hydrogen fueling stations needed to support the widespread roll-out of hydrogen fuel cell electric vehicles, this work presents publicly available station templates and analyses. These ‘Reference Stations’ help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enable quick assessment of potential sites for a hydrogen station, identify contributors to poor economics, and suggest areas of research. This work presents layouts, bills of materials, piping and instrumentation diagrams, and detailed analyses of five new station designs. In the near term, delivered hydrogen results in a lower cost of hydrogen compared to on-site production via steam methane reforming or electrolysis, although the on-site production methods have other advantages. Modular station concepts including on-site production can reduce lot sizes from conventional assemble-on-site stations.

  11. 76 FR 2144 - Quest Diagnostics, Inc. Information Technology Help Desk Services Including On-Site Leased...

    Science.gov (United States)

    2011-01-12

    .... Information Technology Help Desk Services Including On-Site Leased Workers From Modis, West Norriton, PA..., applicable to workers of Quest Diagnostics, Inc., Information Technology Help Desk Services, West Norriton... Quest Diagnostics, Inc., Information Technology Help Desk [[Page 2145

  12. 75 FR 49526 - Halliburton Company, Duncan Mfg., Including On-Site Leased Workers from Express Personnel...

    Science.gov (United States)

    2010-08-13

    ... Company, Duncan Mfg., Including On-Site Leased Workers from Express Personnel, Clayton Personnel Service, and Manpower Planning, Duncan, OK; Halliburton Company, Technology and Engineering Division, Finance... Halliburton Company, Technology and Engineering Division, and Finance and Administration Division, Duncan...

  13. Wilderness Recreation Demand: A Comparison of Travel Cost and On-Site Cost Models

    Science.gov (United States)

    J.M. Bowker; A. Askew; L. Seymour; J.P. Zhu; D. English; C.M. Starbuck

    2009-01-01

    This study used travel cost and on-site day cost models, coupled with the Forest Service’s National Visitor Use Monitoring data, to examine the demand for and value of recreation access to designated Wilderness.

  14. 76 FR 13666 - Pitney Bowes, Inc., Mailing Solutions Management, Global Engineering Group, Including On-Site...

    Science.gov (United States)

    2011-03-14

    ...., Mailing Solutions Management, Global Engineering Group, Including On-Site Leased Workers From Guidant... workers and former workers of Pitney Bowes, Inc., Mailing Solutions Management Division, Engineering... reviewed the certification to clarify the subject worker group's identity. Additional information revealed...

  15. On-Site Processing and Subsampling of Surface Soil Samples for the Analysis of Explosives

    National Research Council Canada - National Science Library

    Hewitt, Alan D

    2003-01-01

    The on-site implementation of a sampling and analysis plan for the determination of explosives residues exposed a large uncertainty in our ability to quickly obtain representative subsamples from either large (>500 g...

  16. AMCO On-Site Air Monitoring Map Service, Oakland CA, Live 2017, US EPA Region 9

    Data.gov (United States)

    U.S. Environmental Protection Agency — This map service contains the following layers: All On-Site Air Monitors, TCE, PCE, and Vinyl Chloride. The layers draws at all scales. Full FGDC metadata for the...

  17. On-site quality assurance during erection of a nuclear power plant

    International Nuclear Information System (INIS)

    Mueller, J.

    1976-01-01

    The paper deals with general quality assurance measures, the quality assurance during on-site production (incoming inspection, inspection of welds and welding equipment) and describes in more detail the quality assurance procedures for the containment. (RW) [de

  18. Accidental Release of Chlorine from a Storage Facility and an On-Site Emergency Mock Drill: A Case Study

    Directory of Open Access Journals (Sweden)

    Ambalathumpara Raman Soman

    2015-01-01

    Full Text Available In the current industrial scenario there is a serious need for formulating strategies to handle hazardous substances in the safest way. Manufacture, storage, and use of hazardous substances pose a serious risk to industry, people, and the environment. Accidental release of toxic chemicals can lead to emergencies. An emergency response plan (ERP is inevitable to minimize the adverse effects of such releases. The on-site emergency plan is an integral component of any process safety and risk management system. This paper deals with an on-site emergency response plan for a chlorine manufacturing industry. It was developed on the basis of a previous study on chlorine release and a full scale mock drill has been conducted for testing the plan. Results indicated that properly trained personnel can effectively handle each level of incidents occurring in the process plant. As an extensive guideline to the district level government authorities for off-site emergency planning, risk zone has also been estimated with reference to a chlorine exposure threshold of 3 ppm.

  19. Recommended criteria for the evaluation of on-site nuclear power plant emergency plans, volume II: criteria

    International Nuclear Information System (INIS)

    1997-01-01

    A critical review of existing Canadian and international nuclear power plant (NPP) emergency plans, evaluation criteria, and approaches has been conducted to provide AECB staff with information which can be used to assess the adequacy of NPP on-site emergency response plans. The results of this work are published in two volumes. Volume I, Basis Document, provides the reasons why certain requirements are in place. It also gives comprehensive references to various standards.Volume II, Criteria, contains the criteria which relate to on-site actions and their integration with control room activities and the roles of off-site responsible organizations. The recommended criteria provide information on what is required, and not on how to accomplish the requirements. The licensees are given the latitude to decide on the methods and processes needed to meet the requirements. The documents do not address NPP off-site plans and response capability, or the control room emergency operating procedures and response capability. This report contains only Volume II: Criteria. 55 refs., 2 tabs., 1 fig

  20. Explanation of procedure on site medical emergency response for nuclear accident

    International Nuclear Information System (INIS)

    Liu Yulong; Jiang Zhong

    2012-01-01

    National occupational health standard-Procedure on Site Medical Emergency Response for Nuclear Accident has been approved and issued by the Ministry of Health. This standard is formulated according to the Emergency Response Law of the People's Republic of China, Law of the People 's Republic of China on Prevention and Control of Occupational Diseases, Regulations on Emergency Measures for Nuclear Accidents at Nuclear Power Plants, and Health Emergency Plans for Nuclear and Radiological Accidents of Ministry of Health, supporting the use of On-site Medical Emergency Planning and Preparedness for Nuclear Accidents and Off-site Medical Emergency Planning and Preparedness for Nuclear Accidents. Nuclear accident on-site medical response procedure is a part of the on-site emergency plan. The standard specifies the basic content and requirements of the nuclear accident on-site medical emergency response procedures of nuclear facilities operating units to guide and regulate the work of nuclear accident on-site medical emergency response of nuclear facilities operating units. The criteria-related contents were interpreted in this article. (authors)

  1. Creating the Total Quality Effective School.

    Science.gov (United States)

    Lezotte, Lawrence W.

    This book shows how Deming's Total Quality Management (TQM) theory for organizational management can be integrated with the effective-schools literature. Part 1 compares the 14 principles of TQM with the tenets of effective-schools research. The second part develops a blueprint for creating the total quality effective school. The conceptual…

  2. Total Removals Reporting

    Data.gov (United States)

    Department of Homeland Security — Data used to report on ICE statistics are obtained through the ICE Integrated Decision Support (IIDS) system data warehouse. The records in this system are refreshed...

  3. Risk-adapted monitoring is not inferior to extensive on-site monitoring: Results of the ADAMON cluster-randomised study.

    Science.gov (United States)

    Brosteanu, Oana; Schwarz, Gabriele; Houben, Peggy; Paulus, Ursula; Strenge-Hesse, Anke; Zettelmeyer, Ulrike; Schneider, Anja; Hasenclever, Dirk

    2017-12-01

    Background According to Good Clinical Practice, clinical trials must protect rights and safety of patients and make sure that the trial results are valid and interpretable. Monitoring on-site has an important role in achieving these objectives; it controls trial conduct at trial sites and informs the sponsor on systematic problems. In the past, extensive on-site monitoring with a particular focus on formal source data verification often lost sight of systematic problems in study procedures that endanger Good Clinical Practice objectives. ADAMON is a prospective, stratified, cluster-randomised, controlled study comparing extensive on-site monitoring with risk-adapted monitoring according to a previously published approach. Methods In all, 213 sites from 11 academic trials were cluster-randomised between extensive on-site monitoring (104) and risk-adapted monitoring (109). Independent post-trial audits using structured manuals were performed to determine the frequency of major Good Clinical Practice findings at the patient level. The primary outcome measure is the proportion of audited patients with at least one major audit finding. Analysis relies on logistic regression incorporating trial and monitoring arm as fixed effects and site as random effect. The hypothesis was that risk-adapted monitoring is non-inferior to extensive on-site monitoring with a non-inferiority margin of 0.60 (logit scale). Results Average number of monitoring visits and time spent on-site was 2.1 and 2.7 times higher in extensive on-site monitoring than in risk-adapted monitoring, respectively. A total of 156 (extensive on-site monitoring: 76; risk-adapted monitoring: 80) sites were audited. In 996 of 1618 audited patients, a total of 2456 major audit findings were documented. Depending on the trial, findings were identified in 18%-99% of the audited patients, with no marked monitoring effect in any of the trials. The estimated monitoring effect is -0.04 on the logit scale with two-sided 95

  4. Study on Distribution Reliability with Parallel and On-site Distributed Generation Considering Protection Miscoordination and Tie Line

    Science.gov (United States)

    Chaitusaney, Surachai; Yokoyama, Akihiko

    In distribution system, Distributed Generation (DG) is expected to improve the system reliability as its backup generation. However, DG contribution in fault current may cause the loss of the existing protection coordination, e.g. recloser-fuse coordination and breaker-breaker coordination. This problem can drastically deteriorate the system reliability, and it is more serious and complicated when there are several DG sources in the system. Hence, the above conflict in reliability aspect unavoidably needs a detailed investigation before the installation or enhancement of DG is done. The model of composite DG fault current is proposed to find the threshold beyond which existing protection coordination is lost. Cases of protection miscoordination are described, together with their consequences. Since a distribution system may be tied with another system, the issues of tie line and on-site DG are integrated into this study. Reliability indices are evaluated and compared in the distribution reliability test system RBTS Bus 2.

  5. Total Quality Leadership

    Science.gov (United States)

    1991-01-01

    More than 750 NASA, government, contractor, and academic representatives attended the Seventh Annual NASA/Contractors Conference on Quality and Productivity. The panel presentations and Keynote speeches revolving around the theme of total quality leadership provided a solid base of understanding of the importance, benefits, and principles of total quality management (TQM). The presentations from the conference are summarized.

  6. Genoptraening efter total knaealloplastik

    DEFF Research Database (Denmark)

    Holm, Bente; Kehlet, Henrik

    2009-01-01

    The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty...

  7. Evaluation of the OnSite malaria rapid test performance in Miandrivazo, Madagascar.

    Science.gov (United States)

    Ravaoarisoa, E; Andriamiandranoro, T; Raherinjafy, R; Jahevitra, M; Razanatsiorimalala, S; Andrianaranjaka, V; Randrianarivelojosia, M

    2017-10-01

    The performance of the malaria rapid diagnostic test OnSite-for detecting pan specific pLDH and Plasmodium falciparum specific HRP2 - was assessed during the malaria transmission peak period in Miandrivazo, in the southwestern part of Madagascar from April 20 to May 6, 2010. At the laboratory, the quality control OnSite Malaria Rapid Test according to the WHO/TDR/FIND method demonstrated that the test had good sensitivity. Of the 218 OnSite tests performed at the Miandrivazo Primary Health Center on patients with fever or a recent history of fever, four (1.8%, 95% CI: 0.6-4.9%) were invalid. Ninety four (43,1%) cases of malaria were confirmed by microscopy, of which 90 were P. falciparum malaria and 4 Plasmodium vivax malaria. With a Cohen's kappa coefficient of 0.94, the agreement between microscopy and OnSite is excellent. Compared with the rapid test CareStart™ commonly used within the public health structures in Madagascar, the sensitivity and specificity of the OnSite test were 97.9% and 96.8%.

  8. Slope stability and bearing capacity of landfills and simple on-site test methods.

    Science.gov (United States)

    Yamawaki, Atsushi; Doi, Yoichi; Omine, Kiyoshi

    2017-07-01

    This study discusses strength characteristics (slope stability, bearing capacity, etc.) of waste landfills through on-site tests that were carried out at 29 locations in 19 sites in Japan and three other countries, and proposes simple methods to test and assess the mechanical strength of landfills on site. Also, the possibility of using a landfill site was investigated by a full-scale eccentric loading test. As a result of this, landfills containing more than about 10 cm long plastics or other fibrous materials were found to be resilient and hard to yield. An on-site full scale test proved that no differential settlement occurs. The repose angle test proposed as a simple on-site test method has been confirmed to be a good indicator for slope stability assessment. The repose angle test suggested that landfills which have high, near-saturation water content have considerably poorer slope stability. The results of our repose angle test and the impact acceleration test were related to the internal friction angle and the cohesion, respectively. In addition to this, it was found that the air pore volume ratio measured by an on-site air pore volume ratio test is likely to be related to various strength parameters.

  9. Laparoscopic total pancreatectomy

    Science.gov (United States)

    Wang, Xin; Li, Yongbin; Cai, Yunqiang; Liu, Xubao; Peng, Bing

    2017-01-01

    Abstract Rationale: Laparoscopic total pancreatectomy is a complicated surgical procedure and rarely been reported. This study was conducted to investigate the safety and feasibility of laparoscopic total pancreatectomy. Patients and Methods: Three patients underwent laparoscopic total pancreatectomy between May 2014 and August 2015. We reviewed their general demographic data, perioperative details, and short-term outcomes. General morbidity was assessed using Clavien–Dindo classification and delayed gastric emptying (DGE) was evaluated by International Study Group of Pancreatic Surgery (ISGPS) definition. Diagnosis and Outcomes: The indications for laparoscopic total pancreatectomy were intraductal papillary mucinous neoplasm (IPMN) (n = 2) and pancreatic neuroendocrine tumor (PNET) (n = 1). All patients underwent laparoscopic pylorus and spleen-preserving total pancreatectomy, the mean operative time was 490 minutes (range 450–540 minutes), the mean estimated blood loss was 266 mL (range 100–400 minutes); 2 patients suffered from postoperative complication. All the patients recovered uneventfully with conservative treatment and discharged with a mean hospital stay 18 days (range 8–24 days). The short-term (from 108 to 600 days) follow up demonstrated 3 patients had normal and consistent glycated hemoglobin (HbA1c) level with acceptable quality of life. Lessons: Laparoscopic total pancreatectomy is feasible and safe in selected patients and pylorus and spleen preserving technique should be considered. Further prospective randomized studies are needed to obtain a comprehensive understanding the role of laparoscopic technique in total pancreatectomy. PMID:28099344

  10. Estonian total ozone climatology

    Directory of Open Access Journals (Sweden)

    K. Eerme

    Full Text Available The climatological characteristics of total ozone over Estonia based on the Total Ozone Mapping Spectrometer (TOMS data are discussed. The mean annual cycle during 1979–2000 for the site at 58.3° N and 26.5° E is compiled. The available ground-level data interpolated before TOMS, have been used for trend detection. During the last two decades, the quasi-biennial oscillation (QBO corrected systematic decrease of total ozone from February–April was 3 ± 2.6% per decade. Before 1980, a spring decrease was not detectable. No decreasing trend was found in either the late autumn ozone minimum or in the summer total ozone. The QBO related signal in the spring total ozone has an amplitude of ± 20 DU and phase lag of 20 months. Between 1987–1992, the lagged covariance between the Singapore wind and the studied total ozone was weak. The spring (April–May and summer (June–August total ozone have the best correlation (coefficient 0.7 in the yearly cycle. The correlation between the May and August total ozone is higher than the one between the other summer months. Seasonal power spectra of the total ozone variance show preferred periods with an over 95% significance level. Since 1986, during the winter/spring, the contribution period of 32 days prevails instead of the earlier dominating 26 days. The spectral densities of the periods from 4 days to 2 weeks exhibit high interannual variability.

    Key words. Atmospheric composition and structure (middle atmosphere – composition and chemistry; volcanic effects – Meteorology and atmospheric dynamics (climatology

  11. Total photon absorption

    International Nuclear Information System (INIS)

    Carlos, P.

    1985-06-01

    The present discussion is limited to a presentation of the most recent total photonuclear absorption experiments performed with real photons at intermediate energy, and more precisely in the region of nucleon resonances. The main sources of real photons are briefly reviewed and the experimental procedures used for total photonuclear absorption cross section measurements. The main results obtained below 140 MeV photon energy as well as above 2 GeV are recalled. The experimental study of total photonuclear absorption in the nuclear resonance region (140 MeV< E<2 GeV) is still at its beginning and some results are presented

  12. [Total artificial heart].

    Science.gov (United States)

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  13. Total 2004 results

    International Nuclear Information System (INIS)

    2005-02-01

    This document presents the 2004 results of Total Group: consolidated account, special items, number of shares, market environment, adjustment for amortization of Sanofi-Aventis merger-related intangibles, 4. quarter 2004 results (operating and net incomes, cash flow), upstream (results, production, reserves, recent highlights), downstream (results, refinery throughput, recent highlights), chemicals (results, recent highlights), Total's full year 2004 results (operating and net income, cash flow), 2005 sensitivities, Total SA parent company accounts and proposed dividend, adoption of IFRS accounting, summary and outlook, main operating information by segment for the 4. quarter and full year 2004: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refined product sales by region, chemicals), Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  14. Total synthesis of ciguatoxin.

    Science.gov (United States)

    Hamajima, Akinari; Isobe, Minoru

    2009-01-01

    Something fishy: Ciguatoxin (see structure) is one of the principal toxins involved in ciguatera poisoning and the target of a total synthesis involving the coupling of three segments. The key transformations in this synthesis feature acetylene-dicobalthexacarbonyl complexation.

  15. Total 2004 results

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-02-01

    This document presents the 2004 results of Total Group: consolidated account, special items, number of shares, market environment, adjustment for amortization of Sanofi-Aventis merger-related intangibles, 4. quarter 2004 results (operating and net incomes, cash flow), upstream (results, production, reserves, recent highlights), downstream (results, refinery throughput, recent highlights), chemicals (results, recent highlights), Total's full year 2004 results (operating and net income, cash flow), 2005 sensitivities, Total SA parent company accounts and proposed dividend, adoption of IFRS accounting, summary and outlook, main operating information by segment for the 4. quarter and full year 2004: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refined product sales by region, chemicals), Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  16. Genoptraening efter total knaealloplastik

    DEFF Research Database (Denmark)

    Holm, Bente; Kehlet, Henrik

    2009-01-01

    The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty rehabilitat......The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty...... rehabilitation. Since hospital stay duration has decreased considerably, the need for post-discharge physiotherapy may also have changed. Thus, the indication for and types of rehabilitation programmes need to be studied within the context of fast-track knee arthroplasty....

  17. Genoptraening efter total knaealloplastik

    DEFF Research Database (Denmark)

    Holm, Bente; Kehlet, Henrik

    2009-01-01

    The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty rehabilitat......The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty...... rehabilitation. Since hospital stay duration has decreased considerably, the need for post-discharge physiotherapy may also have changed. Thus, the indication for and types of rehabilitation programmes need to be studied within the context of fast-track knee arthroplasty. Udgivelsesdato: 2009-Feb-23...

  18. On-site and laboratory evaluations of soundscape quality in recreational urban spaces

    DEFF Research Database (Denmark)

    Bjerre, Lærke Cecilie; Larsen, Thea Mathilde; Sørensen, Anna Josefine

    2017-01-01

    Regulations for quiet urban areas are typically based on sound level limits alone. However, the nonacoustic context may be crucial for subjective soundscape quality. Aims: This study aimed at comparing the role of sound level and nonacoustic context for subjective urban soundscape assessment...... in the presence of the full on-site context, the visual context only, and without context. Materials and Methods: Soundscape quality was evaluated for three recreational urban spaces by using four subjective attributes: loudness, acceptance, stressfulness, and comfort. The sound level was measured at each site......, the availability of the visual context in the listening experiment had no significant effect on the ratings. The participants were overall more positive toward natural sound sources on site. Conclusion: The full immersion in the on-site nonacoustic context may be important when evaluating overall soundscape...

  19. Development of emergency response training program for on-site commanders (1)

    International Nuclear Information System (INIS)

    Hikono, Masaru; Matsui, Yuko; Kanayama, Masaki

    2017-01-01

    Since the Great East Japan Earthquake of 2011, there have been increasing calls for developing the leadership capabilities of managers who are in charge of command and control of the on-site emergency response center at nuclear power plants. Training programs to improve non-technical skills are being developed and introduced. The authors developed an active learning exercise that can be repeatedly performed on-site, targeting on-site commander teams in charge of the initial response in an emergency situation. The exercise forms the core element of a non-technical skills training curriculum. This paper outlines the developed exercise, evaluates the stress on the participants caused by the exercise, and identifies any issues before actually introducing it to a site. (author)

  20. Effects of Edge on-Site Potential in a Honeycomb Topological Magnon Insulator

    Science.gov (United States)

    Pantaleón, Pierre A.; Xian, Yang

    2018-06-01

    While the deviation of the edge on-site potential from the bulk values in a magnonic topological honeycomb lattice leads to the formation of edge states in a bearded boundary, this is not the case for a zigzag termination, where no edge state is found. In a semi-infinite lattice, the intrinsic on-site interactions along the boundary sites generate an effective defect and this gives rise to Tamm-like edge states. If a nontrivial gap is induced, both Tamm-like and topologically protected edge states appear in the band structure. The effective defect can be strengthened by an external on-site potential, and the dispersion relation, velocity and magnon density of the edge states all become tunable.

  1. Supravaginal eller total hysterektomi?

    DEFF Research Database (Denmark)

    Edvardsen, L; Madsen, E M

    1994-01-01

    There has been a decline in the rate of hysterectomies in Denmark in general over the last thirteen years, together with a rise in the number of supravaginal operations over the last two years. The literature concerning the relative merits of the supravaginal and the total abdominal operation is ...... indicate a reduced frequency of orgasm after the total hysterectomy compared with the supravaginal operation. When there are technical problems peroperatively with an increased urologic risk the supravaginal operation is recommended....

  2. Total lymphoid irradiation

    International Nuclear Information System (INIS)

    Sutherland, D.E.; Ferguson, R.M.; Simmons, R.L.; Kim, T.H.; Slavin, S.; Najarian, J.S.

    1983-01-01

    Total lymphoid irradiation by itself can produce sufficient immunosuppression to prolong the survival of a variety of organ allografts in experimental animals. The degree of prolongation is dose-dependent and is limited by the toxicity that occurs with higher doses. Total lymphoid irradiation is more effective before transplantation than after, but when used after transplantation can be combined with pharmacologic immunosuppression to achieve a positive effect. In some animal models, total lymphoid irradiation induces an environment in which fully allogeneic bone marrow will engraft and induce permanent chimerism in the recipients who are then tolerant to organ allografts from the donor strain. If total lymphoid irradiation is ever to have clinical applicability on a large scale, it would seem that it would have to be under circumstances in which tolerance can be induced. However, in some animal models graft-versus-host disease occurs following bone marrow transplantation, and methods to obviate its occurrence probably will be needed if this approach is to be applied clinically. In recent years, patient and graft survival rates in renal allograft recipients treated with conventional immunosuppression have improved considerably, and thus the impetus to utilize total lymphoid irradiation for its immunosuppressive effect alone is less compelling. The future of total lymphoid irradiation probably lies in devising protocols in which maintenance immunosuppression can be eliminated, or nearly eliminated, altogether. Such protocols are effective in rodents. Whether they can be applied to clinical transplantation remains to be seen

  3. Totally optimal decision rules

    KAUST Repository

    Amin, Talha

    2017-11-22

    Optimality of decision rules (patterns) can be measured in many ways. One of these is referred to as length. Length signifies the number of terms in a decision rule and is optimally minimized. Another, coverage represents the width of a rule’s applicability and generality. As such, it is desirable to maximize coverage. A totally optimal decision rule is a decision rule that has the minimum possible length and the maximum possible coverage. This paper presents a method for determining the presence of totally optimal decision rules for “complete” decision tables (representations of total functions in which different variables can have domains of differing values). Depending on the cardinalities of the domains, we can either guarantee for each tuple of values of the function that totally optimal rules exist for each row of the table (as in the case of total Boolean functions where the cardinalities are equal to 2) or, for each row, we can find a tuple of values of the function for which totally optimal rules do not exist for this row.

  4. Totally optimal decision rules

    KAUST Repository

    Amin, Talha M.; Moshkov, Mikhail

    2017-01-01

    Optimality of decision rules (patterns) can be measured in many ways. One of these is referred to as length. Length signifies the number of terms in a decision rule and is optimally minimized. Another, coverage represents the width of a rule’s applicability and generality. As such, it is desirable to maximize coverage. A totally optimal decision rule is a decision rule that has the minimum possible length and the maximum possible coverage. This paper presents a method for determining the presence of totally optimal decision rules for “complete” decision tables (representations of total functions in which different variables can have domains of differing values). Depending on the cardinalities of the domains, we can either guarantee for each tuple of values of the function that totally optimal rules exist for each row of the table (as in the case of total Boolean functions where the cardinalities are equal to 2) or, for each row, we can find a tuple of values of the function for which totally optimal rules do not exist for this row.

  5. 76 FR 19466 - Masco Builder Cabinet Group Including On-Site Leased Workers From Reserves Network, Reliable...

    Science.gov (United States)

    2011-04-07

    ... Builder Cabinet Group Including On-Site Leased Workers From Reserves Network, Reliable Staffing, and Third Dimension Waverly, OH; Masco Builder Cabinet Group Including On-Site Leased Workers From Reserves Network... Group including on-site leased workers from Reserves Network, Jackson, Ohio. The workers produce...

  6. 77 FR 40638 - Syniverse Technologies, Inc., Including On-Site Leased Workers From Insight Global Stone Staffing...

    Science.gov (United States)

    2012-07-10

    ..., Inc., Including On-Site Leased Workers From Insight Global Stone Staffing, and Randstad Formerly Known..., Massachusetts, including on-site leased workers from Insight Global, Stone Staffing, Randstad formerly known as... Insight Global, Stone Staffing, Randstad, formerly known as Sapphire Technologies, were employed on-site...

  7. 77 FR 29362 - Kohler Company, Malvern Division, Including On-Site Leased Workers From Manpower Staffing and Dow...

    Science.gov (United States)

    2012-05-17

    ... Division, Including On-Site Leased Workers From Manpower Staffing and Dow Cleaning Services, Malvern, AR..., and components. The company reports that workers from Dow Cleaning Services were employed on-site at... leased from Dow Cleaning Services working on-site at the Malvern, Arkansas location of Kohler Company...

  8. 75 FR 26793 - Beam Global Spirits & Wine, Including On-Site Leased Workers from Adecco, St. Elizabeth Business...

    Science.gov (United States)

    2010-05-12

    ... & Wine, Including On-Site Leased Workers from Adecco, St. Elizabeth Business Health, Guardsmark, and Lab... 26, 2010, applicable to workers of Beam Global Spirits & Wine, including on-site leased workers from... on-site at the Cincinnati, Ohio location of Beam Global Spirits & Wine. The Department has determined...

  9. Manejo do cateter venoso central totalmente implantado em pacientes oncológicos: revisão integrative Manejo del catéter venoso central totalmente implantado en pacientes oncológicos: revisión integrativa Management of totally implanted catheter in patients with cancer: an integrative review

    Directory of Open Access Journals (Sweden)

    Christiane Inocêncio Vasques

    2009-10-01

    patients with cancer. Thus, the goal of this study was to identify the nursing actions regarding the manipulation and management of totally implanted catheter in patients with cancer. An integrative literature review was conducted. A final sample of 15 articles was evaluated. Findings indicated that nursing actions are directed to the catheter dwelling time, the catheter-related complications, the manipulation and management of the catheter, the patients' perception of the catheter, and the education of patients regarding the catheter care. These findings show the complexities of nursing actions regarding the management of totally implanted catheters. In addition, the findings can be useful for professionals who do not work in oncology who may need to apply this knowledge in their clinical practice.

  10. Methods for estimating on-site ambient air concentrations at disposal sites

    International Nuclear Information System (INIS)

    Hwang, S.T.

    1987-01-01

    Currently, Gaussian type dispersion modeling and point source approximation are combined to estimate the ambient air concentrations of pollutants dispersed downwind of an areawide emission source, using the approach of virtual point source approximation. This Gaussian dispersion modeling becomes less accurate as the receptor comes closer to the source, and becomes inapplicable for the estimation of on-site ambient air concentrations at disposal sites. Partial differential equations are solved with appropriate boundary conditions for use in estimating the on-site concentrations in the ambient air impacted by emissions from an area source such as land disposal sites. Two variations of solution techniques are presented, and their predictions are compared

  11. Compact solitary waves in linearly elastic chains with non-smooth on-site potential

    Energy Technology Data Exchange (ETDEWEB)

    Gaeta, Giuseppe [Dipartimento di Matematica, Universita di Milano, Via Saldini 50, 20133 Milan (Italy); Gramchev, Todor [Dipartimento di Matematica e Informatica, Universita di Cagliari, Via Ospedale 72, 09124 Cagliari (Italy); Walcher, Sebastian [Lehrstuhl A Mathematik, RWTH Aachen, 52056 Aachen (Germany)

    2007-04-27

    It was recently observed by Saccomandi and Sgura that one-dimensional chains with nonlinear elastic interaction and regular on-site potential can support compact solitary waves, i.e. travelling solitary waves with strictly compact support. In this paper, we show that the same applies to chains with linear elastic interaction and an on-site potential which is continuous but non-smooth at minima. Some different features arise; in particular, the speed of compact solitary waves is not uniquely fixed by the equation. We also discuss several generalizations of our findings.

  12. On site PWR fuel inspection measurements for operational and design verification

    International Nuclear Information System (INIS)

    1996-01-01

    The on-site inspection of irradiated Pressurized Water Reactor (PWR) fuel and Non-Fuel Bearing Components (NFBC) is typically limited to visual inspections during refuelings using underwater TV cameras and is intended primarily to confirm whether the components will continue in operation. These inspections do not normally provide data for design verification nor information to benefit future fuel designs. Japanese PWR utilities and Nuclear Fuel Industries Ltd. designed, built, and performed demonstration tests of on-site inspection equipment that confirms operational readiness of PWR fuel and NFBC and also gathers data for design verification of these components. 4 figs, 3 tabs

  13. Carbon and nutrient removal from on-site wastewater using extended-aeration activated sludge and ion exchange.

    Science.gov (United States)

    Safferman, Steven I; Burks, Bennette D; Parker, Robert A

    2004-01-01

    The need to improve on-site wastewater treatment processes is being realized as populations move into more environmentally sensitive regions and regulators adopt the total maximum daily load approach to watershed management. Under many conditions, septic systems do not provide adequate treatment; therefore, advanced systems are required. These systems must remove significant amounts of biochemical oxygen demand (BOD) and suspended solids, and substantially nitrify, denitrify, and remove phosphorus. Many existing advanced on-site wastewater systems effectively remove BOD, suspended solids, and ammonia, but few substantially denitrify and uptake phosphorus. The purpose of this research was to design and test modifications to an existing on-site wastewater treatment system to improve denitrification and phosphorus removal. The Nayadic (Consolidated Treatment Systems, Inc., Franklin, Ohio), an established, commercially available, extended-aeration, activated sludge process, was used to represent a typical existing system. Several modifications were considered based on a literature review, and the option with the best potential was tested. To improve denitrification, a supplemental treatment tank was installed before the Nayadic and a combination flow splitter, sump, and pump box with a recirculation system was installed after it. A recirculation pump returned a high proportion of the system effluent back to the supplemental treatment tank. Two supplemental treatment tank sizes, three flowrates, and three recirculation rates were tested. Actual wastewater was dosed as brief slugs to the system in accordance with a set schedule. Several ion-exchange resins housed in a contact column were tested on the effluent for their potential to remove phosphorus. Low effluent levels of five-day biochemical oxygen demand, suspended solids, and total nitrogen were achieved and substantial phosphorous removal was also achieved using a 3780-L supplemental treatment tank, a recirculation

  14. Total volume versus bouts

    DEFF Research Database (Denmark)

    Chinapaw, Mai; Klakk, Heidi; Møller, Niels Christian

    2018-01-01

    BACKGROUND/OBJECTIVES: Examine the prospective relationship of total volume versus bouts of sedentary behaviour (SB) and moderate-to-vigorous physical activity (MVPA) with cardiometabolic risk in children. In addition, the moderating effects of weight status and MVPA were explored. SUBJECTS....../METHODS: Longitudinal study including 454 primary school children (mean age 10.3 years). Total volume and bouts (i.e. ≥10 min consecutive minutes) of MVPA and SB were assessed by accelerometry in Nov 2009/Jan 2010 (T1) and Aug/Oct 2010 (T2). Triglycerides, total cholesterol/HDL cholesterol ratio (TC:HDLC ratio......, with or without mutual adjustments between MVPA and SB. The moderating effects of weight status and MVPA (for SB only) were examined by adding interaction terms. RESULTS: Children engaged daily in about 60 min of total MVPA and 0-15 min/week in MVPA bouts. Mean total sedentary time was around 7 h/day with over 3...

  15. Integrity at CERN

    CERN Document Server

    Department, HR

    2015-01-01

    In the fulfillment of its mission, CERN relies upon the trust and material support of its Member States and partners, and is committed to exercising exemplary stewardship of the resources with which it is entrusted. Accordingly, CERN expects the highest level of integrity from all its contributors (whether members of the personnel, consultants, contractors working on site, or persons engaged in any other capacity at or on behalf of CERN). Integrity is a core value of CERN, defined in the Code of Conduct as “behaving ethically, with intellectual honesty and being accountable for one’s own actions”.

  16. Total versus subtotal hysterectomy

    DEFF Research Database (Denmark)

    Gimbel, Helga; Zobbe, Vibeke; Andersen, Anna Birthe

    2005-01-01

    The aim of this study was to compare total and subtotal abdominal hysterectomy for benign indications, with regard to urinary incontinence, postoperative complications, quality of life (SF-36), constipation, prolapse, satisfaction with sexual life, and pelvic pain at 1-year postoperative. Eighty...... women chose total and 105 women chose subtotal abdominal hysterectomy. No significant differences were found between the 2 operation methods in any of the outcome measures at 12 months. Fourteen women (15%) from the subtotal abdominal hysterectomy group experienced vaginal bleeding and three women had...

  17. Qualità totale e mobilità totale Total Quality and Total Mobility

    Directory of Open Access Journals (Sweden)

    Giuseppe Trieste

    2010-05-01

    Full Text Available FIABA ONLUS (Italian Fund for Elimination of Architectural Barriers was founded in 2000 with the aim of promoting a culture of equal opportunities and, above all, it has as its main goal to involve public and private institutions to create a really accessible and usable environment for everyone. Total accessibility, Total usability and Total mobility are key indicators to define quality of life within cities. A supportive environment that is free of architectural, cultural and psychological barriers allows everyone to live with ease and universality. In fact, people who access to goods and services in the urban context can use to their advantage time and space, so they can do their activities and can maintain relationships that are deemed significant for their social life. The main aim of urban accessibility is to raise the comfort of space for citizens, eliminating all barriers that discriminate people, and prevent from an equality of opportunity. “FIABA FUND - City of ... for the removal of architectural barriers” is an idea of FIABA that has already affected many regions of Italy as Lazio, Lombardy, Campania, Abruzzi and Calabria. It is a National project which provides for opening a bank account in the cities of referring, in which for the first time, all together, individuals and private and public institutions can make a donation to fund initiatives for the removal of architectural barriers within its own territory for a real and effective total accessibility. Last February the fund was launched in Rome with the aim of achieving a Capital without barriers and a Town European model of accessibility and usability. Urban mobility is a prerequisite to access to goods and services, and to organize activities related to daily life. FIABA promotes the concept of sustainable mobility for all, supported by the European Commission’s White Paper. We need a cultural change in management and organization of public means, which might focus on

  18. Ranking of energy resources within the analysis of total costs for the IRP (Integrated Resources Planning for Energy Resources); Ranqueamento de recursos energeticos dentro da analise de custos completos para o PIR (Planejamento Integrado de Recursos Energeticos)

    Energy Technology Data Exchange (ETDEWEB)

    Reinig, Alexandre Orrico; Cicone Junior, Decio; Galvao, Luiz Claudio Ribeiro [Universidade de Sao Paulo (USP), SP (Brazil). Dept. de Energia e Automacao Eletricas. Grupo de Energia; Udaeta, Miguel Edgar Morales [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2008-07-01

    The objective of this work is to demonstrate the application of the Analytic Hierarchy Process (PAH) with the support of computational tools in the Complete Costs Evaluation (ACC) to classify energy resources, emphasizing as this important method of decision making can be used with the ACC inside of the integrated resources planning for energy resources (PIR). The use of the methodology in question inside of the PIR has as permanent goal to interrelate the complete technical valuation of the resources and its qualitative valuation carried through by the involved and interested (En-In) of the PIR, as well as the evaluation of the resources inside of multidimensional criteria of the ACC. For this the way is presented the way as the evaluation of the social dimension of the ACC in the PIR in the Aracatuba's Administrative Region (RAA) was made and ranking generated with the application of the PAH inside of the ACC. The main result is the validation of the AHP with the use of the Decision Lens for the ACC in the PIR, and from that conclude that the ranking of many energy resources using Decision Lens facilitates the process of PIR in the posterior Wallet of Resources and preferential plan determination. (author)

  19. Cost-effective on-site screening for anaemia in pregnancy in primary ...

    African Journals Online (AJOL)

    syphilis serology. Results are returned days or weeks later depending on local circumstances.2 For some mobile clinics in rural areas, this delay may be as long as a month. On-site screening for ... probably anaemic still require a diagnostic test to determine ... accurate and cheap screening for and diagnosis of anaemia,.

  20. 76 FR 14101 - Meadwestvaco Corporation, Consumer and Office Products Division, Including On-Site Leased Workers...

    Science.gov (United States)

    2011-03-15

    ... undated planning and organizing products. The review shows that on August 21, 2008, a certification of..., Consumer and Office Products Division, Including On-Site Leased Workers From Pro-Tel People, Sidney, NY; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with...

  1. Test methods for on site measurement of resistivity of concrete. A RILEM TC-154 Technical Recommendation

    NARCIS (Netherlands)

    Polder, R.B.

    2000-01-01

    This paper describes methods to assess concrete resistivity on site for various purposes related to corrosion and protection of reinforcement. It is based on a first draft of a RILEM Technical Recommendation. The electrical resistivity of concrete can be related to the two processes involved in

  2. Rapid on-site evaluation of axillary fine-needle aspiration cytology in breast cancer.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-06-01

    Axillary ultrasonography (AUS) and fine-needle aspiration cytology (FNAC) can establish axillary lymph node status before surgery, although this technique is hampered by poor adequacy rates. To achieve consistently high rates of FNAC adequacy, rapid on-site evaluation (ROSE) of FNAC samples was introduced.

  3. 76 FR 73683 - Whirlpool Corporation, Including On-Site Leased Workers From Career Solutions TEC Staffing...

    Science.gov (United States)

    2011-11-29

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,593] Whirlpool Corporation, Including On-Site Leased Workers From Career Solutions TEC Staffing, Andrews International, IBM Corporation... refrigerators and trash compactors. The notice was published in the Federal Register on October 25, 2010 (75 FR...

  4. 76 FR 72978 - Whirlpool Corporation Including On-Site Leased Workers From Career Solutions TEC Staffing...

    Science.gov (United States)

    2011-11-28

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,593] Whirlpool Corporation Including On-Site Leased Workers From Career Solutions TEC Staffing, Andrews International, IBM Corporation... workers are engaged in the production of refrigerators and trash compactors. The notice was published in...

  5. Solitary heat waves in nonlinear lattices with squared on-site potential

    Indian Academy of Sciences (India)

    A model Hamiltonian is proposed for heat conduction in a nonlinear lattice with squared on-site potential using the second quantized operators and averaging the same using a suitable wave function, equations are derived in discrete form for the field amplitude and the properties of heat transfer are examined theoretically.

  6. Solitary heat waves in nonlinear lattices with squared on-site potential

    Indian Academy of Sciences (India)

    Abstract. A model Hamiltonian is proposed for heat conduction in a nonlinear lattice with squared on-site potential using the second quantized operators and averaging the same using a suitable wave function, equations are derived in discrete form for the field amplitude and the prop- erties of heat transfer are examined ...

  7. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    El Haddad, J. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Villot-Kadri, M.; Ismaël, A.; Gallou, G. [IVEA Solution, Centre Scientifique d' Orsay, Bât 503, 91400 Orsay (France); Michel, K.; Bruyère, D.; Laperche, V. [BRGM, Service Métrologie, Monitoring et Analyse, 3 avenue Claude Guillemin, B.P 36009, 45060 Orléans Cedex (France); Canioni, L. [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France); Bousquet, B., E-mail: bruno.bousquet@u-bordeaux1.fr [Univ. Bordeaux, LOMA, UMR 5798, F-33400 Talence (France); CNRS, LOMA, UMR 5798, F-33400 Talence (France)

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced.

  8. 75 FR 11922 - Apria Healthcare, Including On-Site Leased Workers From Corestaff, Ultimate Staffing (Roth...

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,054C] Apria Healthcare..., 2009, applicable to workers of Apria Healthcare, including on-site leased workers from Corestaff... subject firm. The workers are engaged in activities related to the information technology and patient...

  9. 40 CFR 266.108 - Small quantity on-site burner exemption.

    Science.gov (United States)

    2010-07-01

    ...) SOLID WASTES (CONTINUED) STANDARDS FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Hazardous Waste Burned in Boilers and Industrial Furnaces § 266.108... burn hazardous waste in an on-site boiler or industrial furnace are exempt from the requirements of...

  10. Artificial neural network for on-site quantitative analysis of soils using laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    El Haddad, J.; Villot-Kadri, M.; Ismaël, A.; Gallou, G.; Michel, K.; Bruyère, D.; Laperche, V.; Canioni, L.; Bousquet, B.

    2013-01-01

    Nowadays, due to environmental concerns, fast on-site quantitative analyses of soils are required. Laser induced breakdown spectroscopy is a serious candidate to address this challenge and is especially well suited for multi-elemental analysis of heavy metals. However, saturation and matrix effects prevent from a simple treatment of the LIBS data, namely through a regular calibration curve. This paper details the limits of this approach and consequently emphasizes the advantage of using artificial neural networks well suited for non-linear and multi-variate calibration. This advanced method of data analysis is evaluated in the case of real soil samples and on-site LIBS measurements. The selection of the LIBS data as input data of the network is particularly detailed and finally, resulting errors of prediction lower than 20% for aluminum, calcium, copper and iron demonstrate the good efficiency of the artificial neural networks for on-site quantitative LIBS of soils. - Highlights: ► We perform on-site quantitative LIBS analysis of soil samples. ► We demonstrate that univariate analysis is not convenient. ► We exploit artificial neural networks for LIBS analysis. ► Spectral lines other than the ones from the analyte must be introduced

  11. Towards sustainable and robust on-site domestic wastewater treatment for all citizens

    NARCIS (Netherlands)

    Mgana, S.

    2003-01-01

    In most developing countries commonly practiced domestic wastewater treatment systems predominantly constitute anaerobic treatment process. The anaerobic treatment units mostly installed are on-site at residential dwellings.

    However the commonly installed units, viz., traditional pit

  12. 77 FR 48550 - Technicolor Creative Services, Post Production Feature Mastering Division Including On-Site...

    Science.gov (United States)

    2012-08-14

    ... Services, Post Production Feature Mastering Division Including On-Site Leased Workers From Ajilon... Services, Post Production Feature Mastering Division, Hollywood, California (subject firm). The worker... the workers meet the eligibility requirements of the Trade Act of 1974. Conclusion After careful...

  13. The interactive on-site inspection system: An information management system to support arms control inspections

    Energy Technology Data Exchange (ETDEWEB)

    DeLand, S.M.; Widney, T.W.; Horak, K.E.; Caudell, R.B.; Grose, E.M.

    1996-12-01

    The increasing use of on-site inspection (OSI) to meet the nation`s obligations with recently signed treaties requires the nation to manage a variety of inspection requirements. This document describes a prototype automated system to assist in the preparation and management of these inspections.

  14. On-site energy consumption and selected emissions at softwood sawmills in the southwestern United States

    Science.gov (United States)

    Dan Loeffler; Nathaniel Anderson; Todd A. Morgan; Colin B. Sorenson

    2016-01-01

    Presently there is a lack of information describing US southwestern energy consumption and emissions generated from the sawmilling industry. This article uses a mail survey of softwood sawmills in the states of Arizona, Colorado, and New Mexico to develop a profile of on-site energy consumption and selected emissions for the industry. Energy consumption is...

  15. Improvement of Endovascular Stroke Treatment: A 24-Hour Neuroradiological On-Site Service Is Not Enough

    Directory of Open Access Journals (Sweden)

    Omid Nikoubashman

    2018-01-01

    Full Text Available Background and Purpose. With the advent of endovascular stroke treatment (EST with mechanical thrombectomy, stroke treatment has also become more challenging. Purpose of this study was to investigate whether a fulltime neuroradiological on-site service and workflow optimization with a structured documentation of the interdisciplinary stroke workflow resulted in improved procedural times. Material and Methods. Procedural times of 322 consecutive patients, who received EST (1 before (n=96 and (2 after (n=126 establishing a 24-hour neuroradiological on-site service as well as (3 after implementation of a structured interdisciplinary workflow documentation (“Stroke Check” (n=100, were analysed. Results. A fulltime neuroradiological on-site service resulted in a nonsignificant improvement of procedural times during out-of-hours admissions (p≥0.204. Working hours and out-of-hours procedural times improved significantly, if additional workflow optimization was realized (p≤0.026. Conclusions. A 24-hour interventional on-site service is a major prerequisite to adequately provide modern reperfusion therapies in patients with acute ischemic stroke. However, simple measures like standardized and focused documentation that affect the entire interdisciplinary pre- and intrahospital stroke rescue chain seem to be important.

  16. Design considerations for on-site spent-fuel transfer systems

    International Nuclear Information System (INIS)

    Jones, R.H.; Jones, C.R.

    1989-06-01

    Studies on spent fuel shipping logistics and operation make it clear that the use of large casks, i.e., 100--125 tons, is superior to smaller casks of similar construction. This superiority manifests itself in both transportation and/or shipping economics and safety as well as reduced personnel exposure in the processing of the casks. An on-site system for the transfer of spent fuel from the storage pool to a large shipping or storage cask, as well as the transfer of spent fuel directly from a storage cask to a shipping cask, could bring the large cask benefits to those restricted reactors. Sensing the need to look more closely at this opportunity, EPRI contracted with S. Levy, Incorporated of Campbell, CA to develop a set of design considerations for such transfer systems. Rather then embark on another design study, EPRI decided to first identify the system considerations that must be factored into any design. The format for this effort presents both the Consideration and the Rationale for the consideration. The resulting work identified thirty-six General Considerations and two Special Considerations. The Considerations are in the form of mandatory requirements and desirable but nonmandatory requirements. Additionally, a brief economic study was performed to get a feel for the cost considerations of on-site transfers. The study results suggest a relatively narrow set of scenarios where on-site transfers are economically superior to alternatives. These scenarios generally involve the use of concrete casks as on-site storage devices

  17. 78 FR 52982 - Regal Beloit Corporation; Springfield, Missouri Division Including On-site Leased Workers From...

    Science.gov (United States)

    2013-08-27

    ... these workers were sufficiently under the control of the subject firm to be considered leased workers...; Springfield, Missouri Division Including On-site Leased Workers From Penmac Personnel Services and GCA Services Group Springfield, Missouri; Amended Certification Regarding Eligibility to Apply for Worker...

  18. 75 FR 77664 - Honeywell International, Inc., Automation and Control Solutions Division, Including On-Site...

    Science.gov (United States)

    2010-12-13

    ..., Inc., Automation and Control Solutions Division, Including On-Site Leased Workers From Manpower... Solutions Division. The Department has determined that these workers were sufficiently under the control of Honeywell International, Inc., Automation and Control Solutions Division to be considered leased workers...

  19. On-Site Enzyme Production by Trichoderma asperellum for the Degradation of Duckweed

    DEFF Research Database (Denmark)

    Bech, Lasse; Herbst, Florian-Alexander; Grell, Morten Nedergaard

    2015-01-01

    The on-site production of cell wall degrading enzymes is an important strategy for the development of sustainable bio-refinery processes. This study concerns the optimization of production of plant cell wall-degrading enzymes produced by Trichoderma asperellum. A comparative secretome analysis...

  20. 76 FR 19467 - Weyerhaeuser Company, Corporate Headquarters Including On-Site Leased Workers From Volt Services...

    Science.gov (United States)

    2011-04-07

    ... employed on-site at the Federal Way, Washington location of Weyerhaeuser Company, Corporate Headquarters... Company, Corporate Headquarters to be considered leased workers. Based on these findings, the Department... Federal Way, Washington location of Weyerhaeuser Company, Corporate Headquarters. The amended notice...

  1. On-Site Renewable Energy and Green Buildings: A System-Level Analysis.

    Science.gov (United States)

    Al-Ghamdi, Sami G; Bilec, Melissa M

    2016-05-03

    Adopting a green building rating system (GBRSs) that strongly considers use of renewable energy can have important environmental consequences, particularly in developing countries. In this paper, we studied on-site renewable energy and GBRSs at the system level to explore potential benefits and challenges. While we have focused on GBRSs, the findings can offer additional insight for renewable incentives across sectors. An energy model was built for 25 sites to compute the potential solar and wind power production on-site and available within the building footprint and regional climate. A life-cycle approach and cost analysis were then completed to analyze the environmental and economic impacts. Environmental impacts of renewable energy varied dramatically between sites, in some cases, the environmental benefits were limited despite the significant economic burden of those renewable systems on-site and vice versa. Our recommendation for GBRSs, and broader policies and regulations, is to require buildings with higher environmental impacts to achieve higher levels of energy performance and on-site renewable energy utilization, instead of fixed percentages.

  2. 78 FR 8587 - Thomson Reuters, Finance Operations & Technology Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-02-06

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,755] Thomson Reuters, Finance Operations & Technology Division, Including On-Site Leased Workers From Adecco; Eagan, MN; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In accordance with Section 223 of the Trade Act of 1974, as amended (`...

  3. Enhanced On-Site Waste Management of Plasterboard in Construction Works: A Case Study in Spain

    Directory of Open Access Journals (Sweden)

    Ana Jiménez-Rivero

    2017-03-01

    Full Text Available On-site management of construction waste commonly determines its destination. In the case of plasterboard (PB, on-site segregation becomes crucial for closed-loop recycling. However, PB is commonly mixed with other wastes in Spain. In this context, the involvement of stakeholders that can contribute to reversing this current situation is needed. This paper analyzes on-site waste management of PB in Spain through a pilot study of a construction site, with the main objective of identifying best practices to increase waste prevention, waste minimization, and the recyclability of the waste. On-site visits and structured interviews were conducted. The results show five management stages: PB distribution (I; PB installation (II; Construction waste storage at the installation area (III; PB waste segregation at the installation area (IV and PB waste transfer to the PB container and storage (V. The proposed practices refer to each stage and include the merging of Stages III and IV. This measure would avoid the mixing of waste fractions in Stage III, maximizing the recyclability of PB. In addition, two requisites for achieving enhanced management are analyzed: ‘Training and commitment’ and ‘fulfilling the requirements established by the current regulation’. The results show that foremen adopted a more pessimistic attitude than installers towards a joint commitment for waste management. Moreover, not all supervisors valued the importance of a site waste management plan, regulated by the Royal Decree 105/2008 in Spain.

  4. Finding New Water: Development of On-Site Non-Potable Water Reuse Systems

    Science.gov (United States)

    By designing our buildings to collect and treat water generated on-site, can be and reused for flushing our toilets and irrigating our landscaping. Several water sources are generated with-in a building including: rainwater, stormwater, graywater, blackwater and foundation drain...

  5. Pathogen Treatment Guidance and Monitoring Approaches fro On-Site Non-Potable Water Reuse

    Science.gov (United States)

    On-site non-potable water reuse is increasingly used to augment water supplies, but traditional fecal indicator approaches for defining and monitoring exposure risks are limited when applied to these decentralized options. This session emphasizes risk-based modeling to define pat...

  6. Alternative Wastewater Treatment: On-Site Bio-treatment Wetlands at the Fernald Preserve Visitors Center

    International Nuclear Information System (INIS)

    Homer, J.; Glassmeyer, C.; Sauer, N.; Powell, J.

    2009-01-01

    This paper describes the design and operation of a constructed on-site bio-treatment wetland at the Fernald Preserve Visitors Center. The use of constructed wetlands for treatment of domestic wastewater at the Fernald Preserve contributed to the award of Leadership in Energy and Environmental Design platinum certification from the U.S. Green Building Council. (authors)

  7. Performance of on-site Medical waste disinfection equipment in hospitals of Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Hassan Taghipour

    2016-10-01

    Full Text Available Background: The number of studies available on the performance of on-site medical waste treatment facilities is rare, to date. The aim of this study was to evaluate the performance of onsite medical waste treatment equipment in hospitals of Tabriz, Iran. Methods: A various range of the on-site medical waste disinfection equipment (autoclave, chemical disinfection, hydroclave, and dry thermal treatment was considered to select 10 out of 22 hospitals in Tabriz to be included in the survey. The apparatus were monitored mechanically, chemically, and biologically for a six months period in all of the selected hospitals. Results: The results of the chemical monitoring (Bowie-Dick tests indicated that 38.9% of the inspected autoclaves had operational problems in pre-vacuum, air leaks, inadequate steam penetration into the waste, and/or vacuum pump. The biological indicators revealed that about 55.55% of the samples were positive. The most of applied devices were not suitable for treating anatomical, pharmaceutical, cytotoxic, and chemical waste. Conclusion: Although on-site medical waste treating facilities have been installed in all the hospitals, the most of infectious-hazardous medical waste generated in the hospitals were deposited into a municipal solid waste landfill, without enough disinfection. The responsible authorities should stringently inspect and evaluate the operation of on-site medical waste treating equipment. An advanced off-site central facility with multi-treatment and disinfection equipment and enough capacity is recommended as an alternative.

  8. On-site screening for syphilis at an antenatal clinic | Delport | South ...

    African Journals Online (AJOL)

    Objective. To determine the validity, predictive value and accuracy of the rapid plasma reagin card test performed on site to diagnose active syphilis in pregnant women so that immediate treatment can be offered to prevent congenital syphilis. Design. Open, descriptive study. Setting. Antenatal clinic, Mamelodi Hospital, ...

  9. On-site screening for maternal syphilis in an antenatal clinic

    African Journals Online (AJOL)

    Abstract Study objective. To determine the sensitivity, specificity, negative predictive value and positive predictive value of the rapid plasma reagin (RPR) test as performed on site in an antenatal clinic to facilitate immediate diagnosis and treatment of maternal syphilis. Design. Open, descriptive study. Setting. Antenatal ...

  10. On-site screening for maternal syphilis in an antenatal clinic ...

    African Journals Online (AJOL)

    Study objective. To determine the sensitivity, specificity, negative predictive value and positive predictive value of the rapid plasma reagin (RPR) test as performed on site in an antenatal clinic to facilitate immediate diagnosis and treatment of maternal syphilis. Design. Open, descriptive study. Setting. Antenatal clinic ...

  11. On-site and off-site forensic analysis capabilities for proliferation and terrorism prevention

    International Nuclear Information System (INIS)

    Whipple, R.E.; Nunes, P.J.; Reynolds, J.G.; Alcaraz, A.; Hart, B.R.

    2004-01-01

    Full text: We will present current on-site technologies that can be utilized for the screening of explosives, chemical agents, and environmental contaminants. These techniques must have the capability to detect various hazardous materials at very low levels, since they pose a major challenge for first responders. Specifically, the technology must detect concealed explosives or chemical agents on-site rapidly. Lawrence Livermore National Laboratory (LLNL) is currently developing several different high explosive screening and detection technologies for field use. Two technologies that have demonstrated an ability to screen for explosives at low levels are colorimetric spot tests and thin layer chromatography (TLC). Another technology that has demonstrated usefulness for the on-site analysis of unknowns is portable gas chromatography-mass spectrometry (GC-MS) with solid phase micro-extraction (SPME) sampling. Several examples utilizing these technologies and their usefulness will be presented. In addition to developing on-site screening methods, LLNL is an Organization for the Prohibition of Chemical Weapons (OPCW) designated laboratory and is certified to accept CW suspect samples. Currently, LLNL is expanding its ISO-17025 certification to include nuclear forensics and explosives. These off-site forensic analysis capabilities and certified procedures will support the needs for homeland security. We will highlight some of the ISO-17025 requirements to accredit procedures, handle samples, and reports. Work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract W-7405-ENG-48

  12. On-site and off-site forensic analysis capabilities for proliferation and terrorism prevention

    International Nuclear Information System (INIS)

    Hart, B.R.; Whipple, R.E.; Nunes, P.J.; Reynolds, J.G.; Alcaraz, A.

    2004-01-01

    We present current on-site technologies that can be utilized for the screening of explosives, chemical agents, and environmental contaminants. These techniques must have the capability to detect various hazardous materials at very low levels, since they pose a major challenge for first responders. Specifically, the technology must detect concealed explosives or chemical agents on-site rapidly. Lawrence Livermore National Laboratory (LLNL) is currently developing several different high explosive screening and detection technologies for field use. Two technologies that have demonstrated an ability to screen for explosives at low levels are colorimetric spot tests and thin layer chromatography (TLC). Another technology that has demonstrated usefulness for the on-site analysis of unknowns is portable gas chromatography-mass spectrometry (GC-MS) with solid phase micro-extraction (SPME) sampling. Several examples utilizing these technologies and their usefulness will be presented. In addition to developing on-site screening methods, LLNL is an Organization for the Prohibition of Chemical Weapons (OPCW) designated laboratory and is certified to accept CW suspect samples. Currently, LLNL is expanding its ISO-17025 certification to include nuclear forensics and explosives. These off-site forensic analysis capabilities and certified procedures will support the needs for homeland security. We will highlight some of the ISO-17025 requirements to accredit procedures, handle samples, and reports. Work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract W-7405-ENG-48. (author)

  13. On-site voltage measurement with capacitive sensors on high voltage systems

    NARCIS (Netherlands)

    Wu, L.; Wouters, P.A.A.F.; Heesch, van E.J.M.; Steennis, E.F.

    2011-01-01

    In Extra/High-Voltage (EHV/HV) power systems, over-voltages occur e.g. due to transients or resonances. At places where no conventional voltage measurement devices can be installed, on-site measurement of these occurrences requires preferably non intrusive sensors, which can be installed with little

  14. Decision precision or holistic heuristic?: Insights on on-site selection of student nurses and midwives.

    Science.gov (United States)

    Macduff, Colin; Stephen, Audrey; Taylor, Ruth

    2016-01-01

    Concerns about quality of care delivery in the UK have led to more scrutiny of criteria and methods for the selection of student nurses. However few substantive research studies of on-site selection processes exist. This study elicited and interpreted perspectives on interviewing processes and related decision making involved in on-site selection of student nurses and midwives. Individual and focus group interviews were undertaken with 36 lecturers, 5 clinical staff and 72 students from seven Scottish universities. Enquiry focused primarily on interviewing of candidates on-site. Qualitative content analysis was used as a primary strategy, followed by in-depth thematic analysis. Students had very mixed experiences of interview processes. Staff typically took into account a range of candidate attributes that they valued in order to achieve holistic assessments. These included: interpersonal skills, team working, confidence, problem-solving, aptitude for caring, motivations, and commitment. Staff had mixed views of the validity and reliability of interview processes. A holistic heuristic for overall decision making predominated over belief in the precision of, and evidence base for, particular attribute measurement processes. While the development of measurement tools for particular attributes continues apace, tension between holism and precision is likely to persist within on-site selection procedures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. 75 FR 70688 - Actel Corporation, Currently Known as Microsemi Corporation, Including On-Site Leased Workers...

    Science.gov (United States)

    2010-11-18

    ..., Accountants, Inc. and Accountant Temps Mountain View, CA; Amended Certification Regarding Eligibility To Apply... on-site leased workers from ATR International, Accountants, Inc., and Accountant Temps, Mountain View... a separate unemployment insurance (UI) tax account under the name Microsemi Corporation. Accordingly...

  16. Facilitating Employee Recruitment and Retention through On-Site Child Day Care.

    Science.gov (United States)

    Lombardo, Kathy A.

    An early childhood educator at a 360-bed community general hospital implemented a licensed on-site child care program for children between 6 weeks and 10 years of age in order to improve employee recruitment and retention by assisting employees with appropriate child care arrangements. A parent questionnaire was used to assess the degree to which…

  17. Real-time and on-site γ-ray radiation response testing system for semiconductor devices and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Yifei, E-mail: Y.Mu@student.liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Zhao, Ce Zhou, E-mail: cezhou.zhao@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Qi, Yanfei, E-mail: yanfei.qi01@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Lam, Sang, E-mail: s.lam@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Zhao, Chun, E-mail: garyzhao@ust.hk [Nano and Advanced Materials Institute, Hong Kong University of Science and Technology, Kowloon (Hong Kong); Lu, Qifeng, E-mail: qifeng@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Cai, Yutao, E-mail: yutao.cai@xjtlu.edu.cn [Department of Electrical and Electronic Engineering, Xi’an Jiaotong-Liverpool University, Suzhou 215123 (China); Mitrovic, Ivona Z., E-mail: ivona@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Taylor, Stephen, E-mail: s.taylor@liverpool.ac.uk [Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool L69 3GJ (United Kingdom); Chalker, Paul R., E-mail: pchalker@liverpool.ac.uk [Center for Materials and Structures, School of Engineering, University of Liverpool, Liverpool L69 3GH (United Kingdom)

    2016-04-01

    The construction of a turnkey real-time and on-site radiation response testing system for semiconductor devices is reported. Components of an on-site radiation response probe station, which contains a 1.11 GBq Cs{sup 137} gamma (γ)-ray source, and equipment of a real-time measurement system are described in detail for the construction of the whole system. The real-time measurement system includes a conventional capacitance–voltage (C–V) and stress module, a pulse C–V and stress module, a conventional current–voltage (I–V) and stress module, a pulse I–V and stress module, a DC on-the-fly (OTF) module and a pulse OTF module. Electrical characteristics of MOS capacitors or MOSFET devices are measured by each module integrated in the probe station under continuous γ-ray exposure and the measurement results are presented. The dose rates of different gate dielectrics are calculated by a novel calculation model based on the Cs{sup 137} γ-ray source placed in the probe station. For the sake of operators’ safety, an equivalent dose rate of 70 nSv/h at a given operation distance is indicated by a dose attenuation model in the experimental environment. HfO{sub 2} thin films formed by atomic layer deposition are employed to investigate the radiation response of the high-κ material by using the conventional C–V and pulse C–V modules. The irradiation exposure of the sample is carried out with a dose rate of 0.175 rad/s and ±1 V bias in the radiation response testing system. Analysis of flat-band voltage shifts (ΔV{sub FB}) of the MOS capacitors suggests that the on-site and real-time/pulse measurements detect more serious degradation of the HfO{sub 2} thin films compared with the off-site irradiation and conventional measurement techniques.

  18. Hybrid model predictive control of a residential HVAC system with on-site thermal energy generation and storage

    International Nuclear Information System (INIS)

    Fiorentini, Massimo; Wall, Josh; Ma, Zhenjun; Braslavsky, Julio H.; Cooper, Paul

    2017-01-01

    Highlights: • A comprehensive approach to managing thermal energy in residential buildings. • Solar-assisted HVAC system with on-site energy generation and storage. • Mixed logic-dynamical building model identified using experimental data. • Design and implementation of a logic-dynamical model predictive control strategy. • MPC applied to the Net-Zero Energy house winner of the Solar Decathlon China 2013. - Abstract: This paper describes the development, implementation and experimental investigation of a Hybrid Model Predictive Control (HMPC) strategy to control solar-assisted heating, ventilation and air-conditioning (HVAC) systems with on-site thermal energy generation and storage. A comprehensive approach to the thermal energy management of a residential building is presented to optimise the scheduling of the available thermal energy resources to meet a comfort objective. The system has a hybrid nature with both continuous variables and discrete, logic-driven operating modes. The proposed control strategy is organized in two hierarchical levels. At the high-level, an HMPC controller with a 24-h prediction horizon and a 1-h control step is used to select the operating mode of the HVAC system. At the low-level, each operating mode is optimised using a 1-h rolling prediction horizon with a 5-min control step. The proposed control strategy has been practically implemented on the Building Management and Control System (BMCS) of a Net Zero-Energy Solar Decathlon house. This house features a sophisticated HVAC system comprising of an air-based photovoltaic thermal (PVT) collector and a phase change material (PCM) thermal storage integrated with the air-handling unit (AHU) of a ducted reverse-cycle heat pump system. The simulation and experimental results demonstrated the high performance achievable using an HMPC approach to optimising complex multimode HVAC systems in residential buildings, illustrating efficient selection of the appropriate operating modes

  19. A method for the on-site determination of prestressing forces using long-gauge fiber optic strain sensors

    International Nuclear Information System (INIS)

    Abdel-Jaber, H; Glisic, B

    2014-01-01

    Structural health monitoring (SHM) consists of the continuous or periodic measurement of structural parameters and their analysis with the aim of deducing information about the performance and health condition of a structure. The significant increase in the construction of prestressed concrete bridges motivated this research on an SHM method for the on-site determination of the distribution of prestressing forces along prestressed concrete beam structures. The estimation of the distribution of forces is important as it can give information regarding the overall performance and structural integrity of the bridge. An inadequate transfer of the designed prestressing forces to the concrete cross-section can lead to a reduced capacity of the bridge and consequently malfunction or failure at lower loads than predicted by design. This paper researches a universal method for the determination of the distribution of prestressing forces along concrete beam structures at the time of transfer of the prestressing force (e.g., at the time of prestressing or post-tensioning). The method is based on the use of long-gauge fiber optic sensors, and the sensor network is similar (practically identical) to the one used for damage identification. The method encompasses the determination of prestressing forces at both healthy and cracked cross-sections, and for the latter it can yield information about the condition of the cracks. The method is validated on-site by comparison to design forces through the application to two structures: (1) a deck-stiffened arch and (2) a curved continuous girder. The uncertainty in the determination of prestressing forces was calculated and the comparison with the design forces has shown very good agreement in most of the structures’ cross-sections, but also helped identify some unusual behaviors. The method and its validation are presented in this paper. (papers)

  20. CSF total protein

    Science.gov (United States)

    CSF total protein is a test to determine the amount of protein in your spinal fluid, also called cerebrospinal fluid (CSF). ... The normal protein range varies from lab to lab, but is typically about 15 to 60 milligrams per deciliter (mg/dL) ...

  1. Total body irradiation

    International Nuclear Information System (INIS)

    Novack, D.H.; Kiley, J.P.

    1987-01-01

    The multitude of papers and conferences in recent years on the use of very large megavoltage radiation fields indicates an increased interest in total body, hemibody, and total nodal radiotherapy for various clinical situations. These include high dose total body irradiation (TBI) to destroy the bone marrow and leukemic cells and provide immunosuppression prior to a bone marrow transplant, high dose total lymphoid irradiation (TLI) prior to bone marrow transplantation in severe aplastic anemia, low dose TBI in the treatment of lymphocytic leukemias or lymphomas, and hemibody irradiation (HBI) in the treatment of advanced multiple myeloma. Although accurate provision of a specific dose and the desired degree of dose homogeneity are two of the physicist's major considerations for all radiotherapy techniques, these tasks are even more demanding for large field radiotherapy. Because most large field radiotherapy is done at an extended distance for complex patient geometries, basic dosimetry data measured at the standard distance (isocenter) must be verified or supplemented. This paper discusses some of the special dosimetric problems of large field radiotherapy, with specific examples given of the dosimetry of the TBI program for bone marrow transplant at the authors' hospital

  2. Total design of participation

    DEFF Research Database (Denmark)

    Munch, Anders V.

    2016-01-01

    The idea of design as an art made not only for the people, but also by the people is an old dream going back at least to William Morris. It is, however, reappearing vigoriously in many kinds of design activism and grows out of the visions of a Total Design of society. The ideas of participation b...

  3. Total Quality Management Simplified.

    Science.gov (United States)

    Arias, Pam

    1995-01-01

    Maintains that Total Quality Management (TQM) is one method that helps to monitor and improve the quality of child care. Lists four steps for a child-care center to design and implement its own TQM program. Suggests that quality assurance in child-care settings is an ongoing process, and that TQM programs help in providing consistent, high-quality…

  4. Total Quality Management Seminar.

    Science.gov (United States)

    Massachusetts Career Development Inst., Springfield.

    This booklet is one of six texts from a workplace literacy curriculum designed to assist learners in facing the increased demands of the workplace. The booklet contains seven sections that cover the following topics: (1) meaning of total quality management (TQM); (2) the customer; (3) the organization's culture; (4) comparison of management…

  5. Total photon absorption

    International Nuclear Information System (INIS)

    Carlos, P.

    1985-01-01

    Experimental methods using real photon beams for measurements of total photonuclear absorption cross section σ(Tot : E/sub γ/) are recalled. Most recent σ(Tot : E/sub γ/)results for complex nuclei and in the nucleon resonance region are presented

  6. Total 2004 annual report

    International Nuclear Information System (INIS)

    2004-01-01

    This annual report of the Group Total brings information and economic data on the following topics, for the year 2004: the corporate governance, the corporate social responsibility, the shareholder notebook, the management report, the activities, the upstream (exploration and production) and downstream (refining and marketing) operating, chemicals and other matters. (A.L.B.)

  7. Total Water Management - Report

    Science.gov (United States)

    There is a growing need for urban water managers to take a more holistic view of their water resource systems as population growth, urbanization, and current operations put different stresses on the environment and urban infrastructure. Total Water Management (TWM) is an approac...

  8. A Comparison of Online versus On-site Training in Health Research Methodology: A Randomized Study

    Directory of Open Access Journals (Sweden)

    Kanchanaraksa Sukon

    2011-06-01

    Full Text Available Abstract Background Distance learning may be useful for building health research capacity. However, evidence that it can improve knowledge and skills in health research, particularly in resource-poor settings, is limited. We compared the impact and acceptability of teaching two distinct content areas, Biostatistics and Research Ethics, through either on-line distance learning format or traditional on-site training, in a randomized study in India. Our objective was to determine whether on-line courses in Biostatistics and Research Ethics could achieve similar improvements in knowledge, as traditional on-site, classroom-based courses. Methods Subjects: Volunteer Indian scientists were randomly assigned to one of two arms. Intervention: Students in Arm 1 attended a 3.5-day on-site course in Biostatistics and completed a 3.5-week on-line course in Research Ethics. Students in Arm 2 attended a 3.5-week on-line course in Biostatistics and 3.5-day on-site course in Research Ethics. For the two course formats, learning objectives, course contents and knowledge tests were identical. Main Outcome Measures: Improvement in knowledge immediately and 3-months after course completion, compared to baseline. Results Baseline characteristics were similar in both arms (n = 29 each. Median knowledge score for Biostatistics increased from a baseline of 49% to 64% (p Conclusion On-line and on-site training formats led to marked and similar improvements of knowledge in Biostatistics and Research Ethics. This, combined with logistical and cost advantages of on-line training, may make on-line courses particularly useful for expanding health research capacity in resource-limited settings.

  9. Total Analysis System for Ship Structural Strength

    OpenAIRE

    Takuya, Yoneya; Hiroyuki, Kobayashi; Abdul M., Rahim; Yoshimichi, Sasaki; Masaki, Irisawa; Technical Investigation and Information Department, Research Center; Technical Investigation and Information Department, Research Center; Singapore Office; Technical Investigation and Information Department, Research Center; Technical Investigation and Information Department, Research Center

    2001-01-01

    This paper outlines a total analysis system for ship hull structures, which integrates a wide variety of analysis functions to realise practical applications of rational methods for assessing ship structural strength. It is based on direct calculation of wave-induced loads as well as three-dimensional structural analysis of an entire-ship or hold structure. Three major analysis functions of the total system are ship motion and wave load analysis, ship structural analysis and statistical analy...

  10. Total 2003 Results

    International Nuclear Information System (INIS)

    2003-01-01

    This document presents the 2003 results of Total Group: consolidated account, special items, number of shares, market environment, 4. quarter 2003 results, full year 2003 results, upstream (key figures, proved reserves), downstream key figures, chemicals key figures, parent company accounts and proposed dividends, 2004 sensitivities, summary and outlook, operating information by segment for the 4. quarter and full year 2003: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refinery throughput by region, refined product sales by region, chemicals), impact of allocating contribution of Cepsa to net operating income by business segment: equity in income (loss) and affiliates and other items, Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  11. Totally parallel multilevel algorithms

    Science.gov (United States)

    Frederickson, Paul O.

    1988-01-01

    Four totally parallel algorithms for the solution of a sparse linear system have common characteristics which become quite apparent when they are implemented on a highly parallel hypercube such as the CM2. These four algorithms are Parallel Superconvergent Multigrid (PSMG) of Frederickson and McBryan, Robust Multigrid (RMG) of Hackbusch, the FFT based Spectral Algorithm, and Parallel Cyclic Reduction. In fact, all four can be formulated as particular cases of the same totally parallel multilevel algorithm, which are referred to as TPMA. In certain cases the spectral radius of TPMA is zero, and it is recognized to be a direct algorithm. In many other cases the spectral radius, although not zero, is small enough that a single iteration per timestep keeps the local error within the required tolerance.

  12. Total space in resolution

    Czech Academy of Sciences Publication Activity Database

    Bonacina, I.; Galesi, N.; Thapen, Neil

    2016-01-01

    Roč. 45, č. 5 (2016), s. 1894-1909 ISSN 0097-5397 R&D Projects: GA ČR GBP202/12/G061 EU Projects: European Commission(XE) 339691 - FEALORA Institutional support: RVO:67985840 Keywords : total space * resolution random CNFs * proof complexity Subject RIV: BA - General Mathematics Impact factor: 1.433, year: 2016 http://epubs.siam.org/doi/10.1137/15M1023269

  13. MFTF TOTAL benchmark

    International Nuclear Information System (INIS)

    Choy, J.H.

    1979-06-01

    A benchmark of the TOTAL data base management system as applied to the Mirror Fusion Test Facility (MFTF) data base was implemented and run in February and March of 1979. The benchmark was run on an Interdata 8/32 and involved the following tasks: (1) data base design, (2) data base generation, (3) data base load, and (4) develop and implement programs to simulate MFTF usage of the data base

  14. Total - annual report 2005

    International Nuclear Information System (INIS)

    2006-01-01

    This annual report presents the activities and results of TOTAL S.A., french society on oil and gas. It deals with statistics, the managers, key information on financial data and risk factors, information on the Company, unresolved Staff Comments, employees, major Shareholders, consolidated statements, markets, security, financial risks, defaults dividend arrearages and delinquencies, controls and procedures, code of ethics and financial statements. (A.L.B.)

  15. Total Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Rubio, B.; Gelletly, W.

    2007-01-01

    The problem of determining the distribution of beta decay strength (B(GT)) as a function of excitation energy in the daughter nucleus is discussed. Total Absorption Spectroscopy is shown to provide a way of determining the B(GT) precisely. A brief history of such measurements and a discussion of the advantages and disadvantages of this technique, is followed by examples of two recent studies using the technique. (authors)

  16. Sobredentadura total superior implantosoportada

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.

  17. International workshop on site investigation and evaluation based on the siting process in Sweden

    International Nuclear Information System (INIS)

    Andersson, Johan; Stroem, A.

    2001-06-01

    SKB's goal is to commence surface based site investigations in 2002. Extensive preparations are now being made for this transition to the next phase in the siting process for the deep repository for spent nuclear fuel. The purpose of the international workshop on site characterisation held at Aespoe April 2001 was to: present the SKB site investigation and evaluation programme to a group of international experts; discuss whether the available toolbox of investigation methods for surface based site investigations is appropriate and state-of-the-art in an international perspective; and by working group sessions discuss the level of ambition in the programme for site investigation for each discipline. This report summarises the conclusions of the workshop in general terms. Many of the detailed comments and ideas obtained at the workshop have already inspired and will also directly inspire the on-going planning work for site characterisation. The core activity at the workshop was the work performed by working groups. They addressed what should be considered for a site characterisation programme, based on the generic planning made so far by SKB. The working groups also outlined site specific characterisation programmes for the sites suggested by SKB. The tasks were strictly confined to technical and scientific modelling issues. The working group chairmen presented the working group results at the workshop and have also submitted short memos to SKB. The present document is a compilation of these memos. The SKB generic programme as presented in the existing top level documents, 'Requirements and Criteria and Overall Programme', received general endorsement and was appreciated for being comprehensive and systematic. For example, it contains comprehensive lists of parameters to be measured. However, there is need for prioritisation and sequencing. This is actually included in the current planning process at SKB where the generic programme later this year will be adapted to

  18. On-Site Pilot Study - Removal of Uranium, Radium-226 and Arsenic from Impacted Leachate by Reverse Osmosis - 13155

    Energy Technology Data Exchange (ETDEWEB)

    McMurray, Allan; Everest, Chris; Rilling, Ken [Conestoga-Rovers and Associates, 651 Colby Dr, Waterloo, ON (Canada); Vandergaast, Gary [Atomic Energy of Canada Ltd, 115 Toronto Road, Port Hope, ON (Canada); LaMonica, David [RoChem Membrane Systems Inc., 430 30th Street, Hermosa Beach, CA (United States)

    2013-07-01

    Conestoga-Rovers and Associates (CRA-LTD) performed an on-site pilot study at the Welcome Waste Management Facility in Port Hope, Ontario, Canada, to evaluate the effectiveness of a unique leachate treatment process for the removal of radioactive contaminants from leachate impacted by low-level radioactive waste. Results from the study also provided the parameters needed for the design of the CRA-LTD full scale leachate treatment process design. The final effluent water quality discharged from the process to meet the local surface water discharge criteria. A statistical software package was utilized to obtain the analysis of variance (ANOVA) for the results from design of experiment applied to determine the effect of the evaluated factors on the measured responses. The factors considered in the study were: percent of reverse osmosis permeate water recovery, influent coagulant dosage, and influent total dissolved solids (TDS) dosage. The measured responses evaluated were: operating time, average specific flux, and rejection of radioactive contaminants along with other elements. The ANOVA for the design of experiment results revealed that the operating time is affected by the percent water recovery to be achieved and the flocculant dosage over the range studied. The average specific flux and rejection for the radioactive contaminants were not affected by the factors evaluated over the range studied. The 3 month long on-site pilot testing on the impacted leachate revealed that the CRA-LTD leachate treatment process was robust and produced an effluent water quality that met the surface water discharge criteria mandated by the Canadian Nuclear Safety Commission and the local municipality. (authors)

  19. On-Site Pilot Study - Removal of Uranium, Radium-226 and Arsenic from Impacted Leachate by Reverse Osmosis - 13155

    International Nuclear Information System (INIS)

    McMurray, Allan; Everest, Chris; Rilling, Ken; Vandergaast, Gary; LaMonica, David

    2013-01-01

    Conestoga-Rovers and Associates (CRA-LTD) performed an on-site pilot study at the Welcome Waste Management Facility in Port Hope, Ontario, Canada, to evaluate the effectiveness of a unique leachate treatment process for the removal of radioactive contaminants from leachate impacted by low-level radioactive waste. Results from the study also provided the parameters needed for the design of the CRA-LTD full scale leachate treatment process design. The final effluent water quality discharged from the process to meet the local surface water discharge criteria. A statistical software package was utilized to obtain the analysis of variance (ANOVA) for the results from design of experiment applied to determine the effect of the evaluated factors on the measured responses. The factors considered in the study were: percent of reverse osmosis permeate water recovery, influent coagulant dosage, and influent total dissolved solids (TDS) dosage. The measured responses evaluated were: operating time, average specific flux, and rejection of radioactive contaminants along with other elements. The ANOVA for the design of experiment results revealed that the operating time is affected by the percent water recovery to be achieved and the flocculant dosage over the range studied. The average specific flux and rejection for the radioactive contaminants were not affected by the factors evaluated over the range studied. The 3 month long on-site pilot testing on the impacted leachate revealed that the CRA-LTD leachate treatment process was robust and produced an effluent water quality that met the surface water discharge criteria mandated by the Canadian Nuclear Safety Commission and the local municipality. (authors)

  20. Profiling a multiplex short tandem repeat loci from human urine with use of low cost on-site technology for verification of sample authenticity.

    Science.gov (United States)

    Pires, Nuno M M; Tao Dong; Berntzen, Lasse; Lonningdal, Torill

    2017-07-01

    This work focuses on the development of a sophisticated technique via STR typing to unequivocally verify the authenticity of urine samples before sent to laboratories. STR profiling was conducted with the CSF1PO, TPOX, TH01 Multiplex System coupled with a smartphone-based detection method. The promising capability of the method to identify distinct STR profiles from urine of different persons opens the possibility to conduct sample authenticity tests. On-site STR profiling could be realized with a self-contained autonomous device with an integrated PCR microchip shown hereby.

  1. Anaerobic on-site treatment of black water and dairy parlour wastewater in UASB-septic tanks at low temperatures.

    Science.gov (United States)

    Luostarinen, Sari A; Rintala, Jukka A

    2005-01-01

    Anaerobic on-site treatment of synthetic black water (BW) and dairy parlour wastewater (DPWW) was studied in two-phased upflow anaerobic sludge blanket (UASB)-septic tanks at low temperatures (10-20 degrees C). At all temperatures, total chemical oxygen demand (COD(t)) removal was above 90% with BW and above 80% with DPWW and removal of total suspended solids (TSS) above 90% with both wastewaters. Moreover, dissolved COD (COD(dis)) removal was approx. 70% with both wastewaters indicating good biological activity of the sludges. With BW, a single-phased reactor was found sufficient for good COD removals, while with DPWW, a two-phased process was required. Temperature optimum of reactor sludges was still 35 degrees C after long (398d) operation. Most of the nutrients from BW were removed with TSS, while with DPWW nutrient removal was low. In conclusion, UASB-septic tank was found feasible for (pre)treatment of BW and DPWW at low temperatures.

  2. Nutrient loading on subsoils from on-site wastewater effluent, comparing septic tank and secondary treatment systems.

    Science.gov (United States)

    Gill, L W; O'Luanaigh, N; Johnston, P M; Misstear, B D R; O'Suilleabhain, C

    2009-06-01

    The performance of six separate percolation areas was intensively monitored to ascertain the attenuation effects of unsaturated subsoils with respect to on-site wastewater effluent: three sites receiving septic tank effluent, the other three sites receiving secondary treated effluent. The development of a biomat across the percolation areas receiving secondary treated effluent was restricted on these sites compared to those sites receiving septic tank effluent and this created significant differences in terms of the potential nitrogen loading to groundwater. The average nitrogen loading per capita at 1.0m depth of unsaturated subsoil equated to 3.9 g total-N/d for the sites receiving secondary treated effluent, compared to 2.1 g total-N/d for the sites receiving septic tank effluent. Relatively high nitrogen loading was, however, found on the septic tank sites discharging effluent into highly permeable subsoil that counteracted any significant denitrification. Phosphorus removal was generally very good on all of the sites although a clear relationship to the soil mineralogy was determined.

  3. Total Synthesis of Hyperforin.

    Science.gov (United States)

    Ting, Chi P; Maimone, Thomas J

    2015-08-26

    A 10-step total synthesis of the polycyclic polyprenylated acylphloroglucinol (PPAP) natural product hyperforin from 2-methylcyclopent-2-en-1-one is reported. This route was enabled by a diketene annulation reaction and an oxidative ring expansion strategy designed to complement the presumed biosynthesis of this complex meroterpene. The described work enables the preparation of a highly substituted bicyclo[3.3.1]nonane-1,3,5-trione motif in only six steps and thus serves as a platform for the construction of easily synthesized, highly diverse PPAPs modifiable at every position.

  4. Total quality is people

    International Nuclear Information System (INIS)

    Vogel, C.E.

    1991-01-01

    Confronted by changing market conditions and increased global competition, in 1983 the Commercial Nuclear Fuel Division (CNFD) of Westinghouse Electric embarked on an ambitious plan to make total quality the centerpiece of its long-term business strategy. Five years later, the division's efforts in making continuous quality improvement a way of life among its more than 2,000 employees gained national recognition when it was named a charter recipient of the Malcolm Baldridge National Quality Award. What CNFD achieved during the 1980s was a cultural transformation, characterized by an empowered work force committed to a common vision. The company's quality program development strategy is described

  5. Total quality accounting

    Directory of Open Access Journals (Sweden)

    Andrijašević Maja

    2008-01-01

    Full Text Available The focus of competitive "battle" shifted from the price towards non-price instruments, above all, towards quality that became the key variable for profitability increase and achievement of better comparative position of a company. Under such conditions, management of a company, which, according to the established and certified system of total quality, strives towards achieving of a better market position, faces the problem of quality cost measurement and determination. Management, above all, cost accounting can help in solving of this problem, but the question is how much of its potential is being used for that purpose.

  6. Total_Aktion

    DEFF Research Database (Denmark)

    Søndergaard, Morten

    2008-01-01

    digitale medier er registreringen og muligheden for at opbevare og håndtere digital data uden begrænsninger. Oplevelse, registrering og bevaring knyttes sammen i en ny museal virkelighed, hvor samlingens særlige dokumentariske karakter og fokus, som er unikt for Museet for Samtidskunst, er i centrum...... at mikse deres personlige drinks. TOTAL_AKTION viser Hørbar#3, som er en videreudvikling af den første version. METASYN af Carl Emil Carlsen: Metadata er centralt for Carl Emil Carlsens projekt, der betragter museets samling som et ”univers” af værker (analoge og digitale), beskrivelser og relationer. I...

  7. Total Logistic Plant Solutions

    Directory of Open Access Journals (Sweden)

    Dusan Dorcak

    2016-02-01

    Full Text Available The Total Logistics Plant Solutions, plant logistics system - TLPS, based on the philosophy of advanced control processes enables complex coordination of business processes and flows and the management and scheduling of production in the appropriate production plans and planning periods. Main attributes of TLPS is to create a comprehensive, multi-level, enterprise logistics information system, with a certain degree of intelligence, which accepts the latest science and research results in the field of production technology and logistics. Logistic model of company understands as a system of mutually transforming flows of materials, energy, information, finance, which is realized by chain activities and operations

  8. Total Factbook 2003

    International Nuclear Information System (INIS)

    2003-01-01

    This report presents the activities and results of the Group Total-Fina-Elf for the year 2003. It brings information and economic data on the following topics: the corporate and business; the upstream activities with the reserves, the costs, standardized measure and changes of discounted future net cash flow,oil and gas acreage, drilling, liquefied natural gas, pipelines; downstream activities with refining and marketing maps, refinery, petroleum products, sales, retail gasoline outlets; chemicals with sales and operating income by sector, major applications, base chemicals and polymers, intermediates and performance polymers. (A.L.B.)

  9. Total 2004 fact book

    International Nuclear Information System (INIS)

    2004-01-01

    This report presents the activities and results of the Group Total-Fina-Elf for the year 2004. It brings information and economic data on the following topics: the corporate and business; the upstream activities with the reserves, the costs, standardized measure and changes of discounted future net cash flow,oil and gas acreage, drilling, liquefied natural gas, pipelines; downstream activities with refining and marketing maps, refinery, petroleum products, sales, retail gasoline outlets; chemicals with sales and operating income by sector, major applications, base chemicals and polymers, intermediates and performance polymers. (A.L.B.)

  10. TOTAL annual report 2003

    International Nuclear Information System (INIS)

    2004-01-01

    This 2003 annual report of the Group Total provides economical results and information of the society on the following topics: keys data, the corporate governance (Directors charter, board of directors, audit committee, nomination and remuneration committee, internal control procedures, compensation of directors and executive officers), the corporate social responsibility (environmental stewardship, the future of energy management, the safety enhancement, the human resources, ethics and local development), the investor relations, the management report, the upstream exploration and production, the downstream refining, marketing, trading and shipping, the chemicals and financial and legal information. (A.L.B.)

  11. Total knee arthroplasty

    DEFF Research Database (Denmark)

    Schrøder, Henrik M.; Petersen, Michael M.

    2016-01-01

    Total knee arthroplasty (TKA) is a successful treatment of the osteoarthritic knee, which has increased dramatically over the last 30 years. The indication is a painful osteoarthritic knee with relevant radiographic findings and failure of conservative measures like painkillers and exercise...... surgeon seems to positively influence the rate of surgical complications and implant survival. The painful TKA knee should be thoroughly evaluated, but not revised except if a relevant indication can be established. The most frequent indications for revision are: aseptic loosening, instability, infection...

  12. Integral or integrated marketing

    Directory of Open Access Journals (Sweden)

    Davčik Nebojša

    2006-01-01

    Full Text Available Marketing theorists and experts try to develop business efficient organization and to get marketing performance at higher, business integrated level since its earliest beginnings. The core issue in this paperwork is the dialectic and practical approach dilemma should we develop integrated or integral marketing approach in the organization. The presented company cases as well as dialectic and functional explanations of this dilemma clearly shows that integrated marketing is narrower approach than integral marketing if we take as focal point new, unique and completed entity. In the integration the essence is in getting different parts together, which do not have to make necessary the new entity. The key elements in the definition of the integral marketing are necessity and holistic, e.g. necessity to develop new, holistic entity.

  13. Experience in verification regimes. United States On-Site Inspection Agency

    International Nuclear Information System (INIS)

    Reppert, J.

    1998-01-01

    Experiences are described of the United States On-site Inspection Agency in verification regimes all over the world where it has been applied in the last 30 years. The challenge for the future is to extend the benefits of the applied tools to all states in all regions to enhance stability and to create conditions for peace at lower levels of armaments than currently exist. The USA need to engage states currently caught in cycles of violence and arms escalation. They must examine technologies which together with on-site aspects of verification or transparency regimes can provide a comprehensive picture at affordable costs. They foresee a growth in combined training with new states entering for the first time into regime that include arms control and transparency measure

  14. Generation, on-site storage; handling and processing of industrial waste of Tehran

    International Nuclear Information System (INIS)

    Abduli, M.A.

    1997-01-01

    This paper describes out the present status of generation, on-site handling, processing and storage of industrial waste in Tehran. In this investigation, 67 large scale factories of different industrial groups were randomly selected. Above cited functional elements of these factories were surveyed. In this investigation a close contact with each factory was required, thus a questionnaire was prepared and distributed among these factories. The relationship between daily weight of the industrial waste (Y) and number of employer of each factory (x) is found to be Y=547.4 + 0.58 x. The relationship between daily volume of industrial waste (V), and daily weight of waste generated in each factory (Y) can be described by V=1.56 + 0.00078 Y. About 68% of the factories have their own interim storage site and the rest of the factories do not possess any on-site storage facility

  15. Procurement Specifications Templates for On-Site Solar Photovoltaic: For Use in Developing Federal Solicitations

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-01-16

    With the increasing adaption of on-site renewable energy systems designed to feed site loads, there is a critical need to develop tools that allow the federal sector to become a mature and sophisticated consumer. This document is intended to reduce project development and operational risks while increasing the speed at which projects are completed; two necessary components to reach the scale required to meet mandates and achieve cost savings for taxpayers. This guide is intended to act as a living document where lessons learned from the increasing number of projects can be incorporated and provide guidance for efforts. While additional guides will be developed to cover other renewable technologies, this guide covers on-site solar photovoltaic systems with an emphasis on third-party designed, financed, owned, and operated systems.

  16. On-site storage of high level nuclear waste: attitudes and perceptions of local residents.

    Science.gov (United States)

    Bassett, G W; Jenkins-Smith, H C; Silva, C

    1996-06-01

    No public policy issue has been as difficult as high-level nuclear waste. Debates continue regarding Yucca Mountain as a disposal site, and-more generally-the appropriateness of geologic disposal and the need to act quickly. Previous research has focused on possible social, political, and economic consequences of a facility in Nevada. Impacts have been predicted to be potentially large and to emanate mainly from stigmatization of the region due to increased perceptions of risk. Analogous impacts from leaving waste at power plants have been either ignored or assumed to be negligible. This paper presents survey results on attitudes of residents in three counties where nuclear waste is currently stored. Topics include perceived risk, knowledge of nuclear waste and radiation, and impacts on jobs, tourism, and housing values from leaving waste on site. Results are similar to what has been reported for Nevada; the public is concerned about possible adverse effects from on-site storage of waste.

  17. Evolution of the on-site electric power sources on French 900 MWe PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Bera, Jean [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, Departement d' Analyse de Surete, Service d' Analyse Fonctionnelle, Institut de Protection et Surete Nucleaire, B.P. No. 6, 92260 Fontenay-aux-Roses (France)

    1986-02-15

    Additional means have been provided on the French 900 MWe PWRs to improve safety if both the off-site and on-site Power sources are lost, namely: - a primary pump seal water injection device, one for two units; - a gas turbine generator for each site; - supplying any failing unit with electric power from a house load operating unit; - supplying a unit from a diesel generator of another unit. (author)

  18. Recent chemical engineering requirements as the result of TMI on-site experience

    International Nuclear Information System (INIS)

    Brooksbank, R.E. Sr.

    1980-01-01

    From the experiences gained from the on-site experience at TMI, it is apparent that the role of chemical engineers should increase in order for the nuclear option to proceed in a safe and efficient fashion. It is also obvious that as the results of the reports investigating the causes and effects of the accident come to light and attempts to backfit system designs to prevent a recurrence are studied, more technical demands will be placed on the profession

  19. Rapid on-site detection of Acidovorax citrulli by cross-priming amplification.

    Science.gov (United States)

    Zhang, Jing; Tian, Qian; Zhu, Shui-fang; Zhao, Wen-jun; Liu, Feng-quan

    2012-08-01

    Cross-priming amplification (CPA) for Acidovorax citrulli detection was evaluated in this study. The sensitivity of CPA assay for pure bacterial culture was 3.7 × 10(3) CFU/ml. Bacteria on naturally infected watermelon seeds were detected using CPA assay, suggesting this method is suitable for A. citrulli on-site detection from watermelon seeds. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. On-site interim storage of spent nuclear fuel: Emerging public issues

    International Nuclear Information System (INIS)

    Feldman, D.L.; Tennessee Univ., Knoxville, TN

    1992-01-01

    Failure to consummate plans for a permanent repository or above- ground interim Monitored Retrievable Storage (MRS) facility for spent nuclear fuel has spurred innovative efforts to ensure at-reactor storage in an environmentally safe and secure manner. This article examines the institutional and socioeconomic impacts of Dry Cask Storage Technology (DCST)-an approach to spent fuel management that is emerging as the preferred method of on-site interim spent fuel storage by utilities that exhaust existing storage capacity

  1. Framatome recent developments and application on site in NDE of steam generator tubes

    International Nuclear Information System (INIS)

    Bieth, M.

    1986-01-01

    The increasing needs concerning the follow up and expertise of PWR steam generator (SG) tubing have led Framatome to develop a quick on-site intervention mobile unit, which could implement any current technique and equipment. Besides, Framatome has developed several non destructrive examination methods to solve the specific problems encountered in service on the SG tubes: profilometry of the SG tubes by eddy current. Inside and above the tube sheet, eddy current inspection of tube sleeving by ultrasonic testing and eddy current

  2. TOTAL user manual

    Science.gov (United States)

    Johnson, Sally C.; Boerschlein, David P.

    1994-01-01

    Semi-Markov models can be used to analyze the reliability of virtually any fault-tolerant system. However, the process of delineating all of the states and transitions in the model of a complex system can be devastatingly tedious and error-prone. Even with tools such as the Abstract Semi-Markov Specification Interface to the SURE Tool (ASSIST), the user must describe a system by specifying the rules governing the behavior of the system in order to generate the model. With the Table Oriented Translator to the ASSIST Language (TOTAL), the user can specify the components of a typical system and their attributes in the form of a table. The conditions that lead to system failure are also listed in a tabular form. The user can also abstractly specify dependencies with causes and effects. The level of information required is appropriate for system designers with little or no background in the details of reliability calculations. A menu-driven interface guides the user through the system description process, and the program updates the tables as new information is entered. The TOTAL program automatically generates an ASSIST input description to match the system description.

  3. Assessment of On-site sanitation system on local groundwater regime in an alluvial aquifer

    Science.gov (United States)

    Quamar, Rafat; Jangam, C.; Veligeti, J.; Chintalapudi, P.; Janipella, R.

    2017-12-01

    The present study is an attempt to study the impact of the On-site sanitation system on the groundwater sources in its vicinity. The study has been undertaken in the Agra city of Yamuna sub-basin. In this context, sampling sites (3 nos) namely Pandav Nagar, Ayodhya Kunj and Laxmi Nagar were selected for sampling. The groundwater samples were analyzed for major cations, anions and faecal coliform. Critical parameters namely chloride, nitrate and Faecal coliform were considered to assess the impact of the On-site sanitation systems. The analytical results shown that except for chloride, most of the samples exceeded the Bureau of Indian Standard limits for drinking water for all the other analyzed parameters, i.e., nitrate and faecal coliform in the first two sites. In Laxmi Nagar, except for faecal coliform, all the samples are below the BIS limits. In all the three sites, faecal coliform was found in majority of the samples. A comparison of present study indicates that the contamination of groundwater in alluvial setting is less as compared to hard rock where On-site sanitation systems have been implemented.

  4. On-Site or Off-Site Renewable Energy Supply Options?

    DEFF Research Database (Denmark)

    Marszal, Anna Joanna; Heiselberg, Per; Jensen, Rasmus Lund

    2012-01-01

    The concept of a Net Zero Energy Building (Net ZEB) encompasses two options of supplying renewable energy, which can offset energy use of a building, in particular on-site or off-site renewable energy supply. Currently, the on-site options are much more popular than the off-site; however, taking...... into consideration the limited area of roof and/or façade, primarily in the dense city areas, the Danish weather conditions, the growing interest and number of wind turbine co-ops, the off-site renewable energy supply options could become a meaningful solution for reaching ‘zero’ energy goal in the Danish context...... five technologies, i.e., two on-site options: (1) photovoltaic, (2) micro combined heat and power, and three off-site options: (1) off-site windmill, (2) share of a windmill farm and (3) purchase of green energy from the 100% renewable utility grid. The results indicate that in case of the on...

  5. On-Site Chiropractic Care as an Employee Benefit: A Single-Location Case Study.

    Science.gov (United States)

    Minicozzi, Salvatore J; Russell, Brent S

    2017-09-01

    The purpose of this report is to describe the role of on-site chiropractic care in one corporate environment. A part-time chiropractic practice that provides services to a single company on site, 1 day per week, is described. Most care is oriented toward "wellness," is paid for by the employer, and is limited only by the chiropractor's few weekly hours of on-site availability. With approval from the company, the authors conducted an absenteeism analysis after obtaining ethics approval and consent from employee-patients who received care between 2012 and 2014. Comparisons of absenteeism rates of the sample were compared with lost worktime rates from the US Bureau of Labor Statistics' Labor Force Statistics. Of 40 current employees, 35 used chiropractic services; 17 employee-patients met the inclusion criteria. The lost worktime rates of those using chiropractic services (0.72%, 0.55%, and 0.67%, for 2012, 2013, and 2014, respectively) were lower than corresponding rates from Labor Force Statistics (1.5%, 1.2%, and 1.1%). Absenteeism for the employee-patients was lower than equivalent national figures in this sample of workers. Though these results may or may not be related to the chiropractic care, these findings prompt further investigation into this relationship.

  6. Propagation of transition fronts in nonlinear chains with non-degenerate on-site potentials

    Science.gov (United States)

    Shiroky, I. B.; Gendelman, O. V.

    2018-02-01

    We address the problem of transition front propagation in chains with a bi-stable nondegenerate on-site potential and a nonlinear gradient coupling. For generic nonlinear coupling, one encounters a special regime of transitions, characterized by extremely narrow fronts, far supersonic velocities of the front propagation, and long waves in the oscillatory tail. This regime can be qualitatively associated with a shock wave. The front propagation can be described with the help of a simple reduced-order model; the latter delivers a kinetic law, which is almost not sensitive to the fine details of the on-site potential. Besides, it is possible to predict all main characteristics of the transition front, including its velocity, as well as the frequency and the amplitude of the oscillatory tail. Numerical results are in good agreement with the analytical predictions. The suggested approach allows one to consider the effects of an external pre-load, the next-nearest-neighbor coupling and the on-site damping. When the damping is moderate, it is possible to consider the shock propagation in the damped chain as a perturbation of the undamped dynamics. This approach yields reasonable predictions. When the damping is high, the transition front enters a completely different asymptotic regime of a subsonic kink. The gradient nonlinearity generically turns negligible, and the propagating front converges to the regime described by a simple exact solution for a continuous model with linear coupling.

  7. On-site customization of silicone stents: towards optimal palliation of complex airway conditions.

    Science.gov (United States)

    Breen, David P; Dutau, Hervé

    2009-01-01

    Stents may be indicated as treatment of benign and malignant conditions of the central airways. Occasionally, aberrant and/or distorted airways secondary to therapy or surgery may preclude the use of commercially manufactured stents. The customization of stents is well described for nonpulmonary diseases, but to date there are only limited data in the literature on prosthesis customization for airway disease. To review all the different techniques and indications of on-site silicone stent customizations and their related complications. A retrospective study was undertaken to identify all patients who underwent treatment with a silicone stent which was customized on site by the physician. The study included subjects treated during an 8-year period. Forty-nine on-site customizations were performed in 43 patients (34 males, mean age 63 +/- 5.2 years). Stent customization was performed in 5.4% of the cases. Stent customization was performed for malignant and benign disease in 35 (81.3%) and 8 (18.7%) cases, respectively. In all cases, the stent deployed successfully and performed well while in situ. Stent manipulation did not increase complications. Customization of airway stents by the physician can lead to successful stenting of difficult airway lesions with a good short-term safety profile. Standard commercially available stents may have resulted in suboptimal management of complex airway pathologies. A prospective study is warranted to further investigate the safety profile and complications associated with stent customization. Copyright 2009 S. Karger AG, Basel.

  8. Total process surveillance: (TOPS)

    International Nuclear Information System (INIS)

    Millar, J.H.P.

    1992-01-01

    A Total Process Surveillance system is under development which can provide, in real-time, additional process information from a limited number of raw measurement signals. This is achieved by using a robust model based observer to generate estimates of the process' internal states. The observer utilises the analytical reduncancy among a diverse range of transducers and can thus accommodate off-normal conditions which lead to transducer loss or damage. The modular hierarchical structure of the system enables the maximum amount of information to be assimilated from the available instrument signals no matter how diverse. This structure also constitutes a data reduction path thus reducing operator cognitive overload from a large number of varying, and possibly contradictory, raw plant signals. (orig.)

  9. Total and EDF invest

    International Nuclear Information System (INIS)

    Signoret, St.

    2008-01-01

    So as to prepare the future of their industrial sector,the Total company plans to invest (14 billion Euros in 2008) to increase its production capacities and strengthen in of other activities as the liquefied natural gas and the renewable energies; EDF plans to inject 35 billion Euros over three years to multiply the new projects of power plants (wind turbines, coal in Germany, gas in Great Britain and nuclear power in Flamanville). EDF wants to exploit its knowledge of leader to run more than ten E.P.R.(European pressurized water reactor) in the world before 2020, projects are in examination with China, Great Britain, South Africa and United States. (N.C.)

  10. Total quality at source

    International Nuclear Information System (INIS)

    Chiandone, A.C.

    1990-01-01

    The Total Quality at Source philosophy is based on optimizing the effectiveness of people in achieving ZERO-DEFECT results. In this paper a philosophy of what, I have come to perceive, it takes to get people to perform to the very best of their abilities and thereby achieve the best results they can, is presented. In the examples I shall describe I have played an instrumental role since it has become my belief that any job can always be done better provided that the people doing it can themselves become convinced that they can do better. Clearly there are many ideas on how to do this. The philosophy that I am presenting in this paper is based on my own experience, where I have both participated and observed it being applied; its effectiveness may be judged by the results. (author)

  11. Total ankle joint replacement.

    Science.gov (United States)

    2016-02-01

    Ankle arthritis results in a stiff and painful ankle and can be a major cause of disability. For people with end-stage ankle arthritis, arthrodesis (ankle fusion) is effective at reducing pain in the shorter term, but results in a fixed joint, and over time the loss of mobility places stress on other joints in the foot that may lead to arthritis, pain and dysfunction. Another option is to perform a total ankle joint replacement, with the aim of giving the patient a mobile and pain-free ankle. In this article we review the efficacy of this procedure, including how it compares to ankle arthrodesis, and consider the indications and complications. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Design Status and Applications of Small reactors without On-site Refuelling

    International Nuclear Information System (INIS)

    Kuznetsov, V.

    2006-01-01

    Small reactors without on-site refuelling are the reactors that can operate without reloading and shuffling of fuel for a reasonably long period, consistent with plant economy and considerations of energy security, with no fresh or spent fuel being stored at a site during reactor operation. Such reactors could simplify the implementation of safeguards and provide certain guarantees of sovereignty to those countries that would prefer to lease fuel from a foreign vendor or, perhaps, an international fuel cycle centre. About 30 concepts of such reactors are being analyzed or developed in 6 IAEA Member States. They cover all principle reactor lines: water cooled, fast gas cooled, sodium cooled, lead or lead bismuth cooled and molten salt cooled reactors. An increased refuelling interval could be achieved with reduced core power density, burnable absorbers, or high conversion ratio. The design goals for small reactors without on-site refuelling, inter alia, include: difficult unauthorized access to fuel; design provisions to facilitate the implementation of safeguards; capability to survive all postulated accident scenarios without requiring emergency response in the public domain; economic competitiveness for anticipated market conditions and applications; the capability to achieve higher manufacturing quality through factory mass production, design standardization and common basis for design certification; and a flexibility in siting and applications. Such reactors are often considered in conjunction with fuel or NPP leasing Small reactors without on-site refuelling have many common technology development issues related to the provision of lifetime core operation, economic competitiveness, high level of safety and proliferation resistance. Reestablishment of a practice of licensing by test and establishment of legal provisions and the insurance scheme for a transit of fuel loads or factory fabricated reactors through the territory of a third country are mentioned as

  13. Testing the applicability of rapid on-site enzymatic activity detection for surface water monitoring

    Science.gov (United States)

    Stadler, Philipp; Vogl, Wolfgang; Juri, Koschelnik; Markus, Epp; Maximilian, Lackner; Markus, Oismüller; Monika, Kumpan; Peter, Strauss; Regina, Sommer; Gabriela, Ryzinska-Paier; Farnleitner Andreas, H.; Matthias, Zessner

    2015-04-01

    On-site detection of enzymatic activities has been suggested as a rapid surrogate for microbiological pollution monitoring of water resources (e.g. using glucuronidases, galactosidases, esterases). Due to the possible short measuring intervals enzymatic methods have high potential as near-real time water quality monitoring tools. This presentation describes results from a long termed field test. For twelve months, two ColiMinder devices (Vienna Water Monitoring, Austria) for on-site determination of enzymatic activity were tested for stream water monitoring at the experimental catchment HOAL (Hydrological Open Air Laboratory, Center for Water Resource Systems, Vienna University of Technology). The devices were overall able to follow and reflect the diverse hydrological and microbiological conditions of the monitored stream during the test period. Continuous data in high temporal resolution captured the course of enzymatic activity in stream water during diverse rainfall events. The method also proofed sensitive enough to determine diurnal fluctuations of enzymatic activity in stream water during dry periods. The method was able to capture a seasonal trend of enzymatic activity in stream water that matches the results gained from Colilert18 analysis for E. coli and coliform bacteria of monthly grab samples. Furthermore the comparison of ColiMinder data with measurements gained at the same test site with devices using the same method but having different construction design (BACTcontrol, microLAN) showed consistent measuring results. Comparative analysis showed significant differences between measured enzymatic activity (modified fishman units and pmol/min/100ml) and cultivation based analyses (most probable number, colony forming unit). Methods of enzymatic activity measures are capable to detect ideally the enzymatic activity caused by all active target bacteria members, including VBNC (viable but nonculturable) while cultivation based methods cannot detect VBNC

  14. On-site phytoremediation applicability assessment in Alur Ilmu, Universiti Kebangsaan Malaysia based on spatial and pollution removal analyses.

    Science.gov (United States)

    Mahmud, Mohd Hafiyyan; Lee, Khai Ern; Goh, Thian Lai

    2017-10-01

    The present paper aims to assess the phytoremediation performance based on pollution removal efficiency of the highly polluted region of Alur Ilmu urban river for its applicability of on-site treatment. Thirteen stations along Alur Ilmu were selected to produce thematic maps through spatial distribution analysis based on six water quality parameters of Malaysia's Water Quality Index (WQI) for dry and raining seasons. The maps generated were used to identify the highly polluted region for phytoremediation applicability assessment. Four free-floating plants were tested in treating water samples from the highly polluted region under three different conditions, namely controlled, aerated and normal treatments. The selected free-floating plants were water hyacinth (Eichhornia crassipes), water lettuce (Pistia stratiotes), rose water lettuce (Pistia sp.) and pennywort (Centella asiatica). The results showed that Alur Ilmu was more polluted during dry season compared to raining season based on the water quality analysis. During dry season, four parameters were marked as polluted along Alur Ilmu, namely dissolve oxygen (DO), 4.72 mg/L (class III); ammoniacal nitrogen (NH 3 -N), 0.85 mg/L (class IV); total suspended solid (TSS), 402 mg/L (class V) and biological oxygen demand (BOD), 3.89 mg/L (class III), whereas, two parameters were classed as polluted during raining season, namely total suspended solid (TSS), 571 mg/L (class V) and biological oxygen demand (BOD), 4.01 mg/L (class III). The thematic maps generated from spatial distribution analysis using Kriging gridding method showed that the highly polluted region was recorded at station AL 5. Hence, water samples were taken from this station for pollution removal analysis. All the free-floating plants were able to reduce TSS and COD in less than 14 days. However, water hyacinth showed the least detrimental effect from the phytoremediation process compared to other free-floating plants, thus made it a suitable

  15. Maximizing biofuel production in a thermochemical biorefinery by adding electrolytic hydrogen and by integrating torrefaction with entrained flow gasification

    DEFF Research Database (Denmark)

    Clausen, Lasse Røngaard

    2015-01-01

    double the biofuel production per biomass input by converting almost all of the carbon in the biomass feed to carbon stored in the biofuel product. Water or steam electrolysis can supply the hydrogen to the biorefinery and also the oxygen for the gasifier. This paper presents the design and thermodynamic...... analysis of two biorefineries integrating water electrolysis for the production of methanol. In both plants, torrefied woody biomass is supplied to an entrained flow gasifier, but in one of the plants, the torrefaction process occurs on-site, as it is integrated with the entrained flow gasification process....... The analysis shows that the biorefinery with integrated torrefaction has a higher biomass to methanol energy ratio (136% vs. 101%) as well as higher total energy efficiency (62% vs. 56%). By comparing with two identical biorefineries without electrolysis, it is concluded that the biorefinery with integrated...

  16. Total lymphoid irradiation

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    An outline review notes recent work on total lymphoid irradiation (TLI) as a means of preparing patients for grafts and particularly for bone-marrow transplantation. T.L.I. has proved immunosuppressive in rats, mice, dogs, monkeys and baboons; when given before bone-marrow transplantation, engraftment took place without, or with delayed rejection or graft-versus-host disease. Work with mice has indicated that the thymus needs to be included within the irradiation field, since screening of the thymus reduced skin-graft survival from 50 to 18 days, though irradiation of the thymus alone has proved ineffective. A more lasting tolerance has been observed when T.L.I. is followed by an injection of donor bone marrow. 50% of mice treated in this way accepted allogenic skin grafts for more than 100 days, the animals proving to be stable chimeras with 50% of their peripheral blood lymphocytes being of donor origin. Experiments of a similar nature with dogs and baboons were not so successful. (U.K.)

  17. The total artificial heart.

    Science.gov (United States)

    Cook, Jason A; Shah, Keyur B; Quader, Mohammed A; Cooke, Richard H; Kasirajan, Vigneshwar; Rao, Kris K; Smallfield, Melissa C; Tchoukina, Inna; Tang, Daniel G

    2015-12-01

    The total artificial heart (TAH) is a form of mechanical circulatory support in which the patient's native ventricles and valves are explanted and replaced by a pneumatically powered artificial heart. Currently, the TAH is approved for use in end-stage biventricular heart failure as a bridge to heart transplantation. However, with an increasing global burden of cardiovascular disease and congestive heart failure, the number of patients with end-stage heart failure awaiting heart transplantation now far exceeds the number of available hearts. As a result, the use of mechanical circulatory support, including the TAH and left ventricular assist device (LVAD), is growing exponentially. The LVAD is already widely used as destination therapy, and destination therapy for the TAH is under investigation. While most patients requiring mechanical circulatory support are effectively treated with LVADs, there is a subset of patients with concurrent right ventricular failure or major structural barriers to LVAD placement in whom TAH may be more appropriate. The history, indications, surgical implantation, post device management, outcomes, complications, and future direction of the TAH are discussed in this review.

  18. Education on Risk Management with Gender Equity: Experiences in United Nations Development Programme (UNDP) courses using on-site education and synchronous technologies for distance education

    Science.gov (United States)

    Cepeda, J.; Marroquín, W.; Villar, Y.

    2009-04-01

    The experiences in two Risk Management courses organised by the Universidad Centroamericana "José Simeón Cañas" (UCA) and the "América Latina Genera" project of the BCPR-UNDP (Bureau for Crisis Prevention and Recovery of the United Nations Development Programme) are presented focusing on the design of teaching material and the selection and use of information-communication technologies (ICT) during the learning process. The organisation of these courses has posed three main challenges: the integration of a gender-equity approach in a subject that has traditionally lacked of it, the preparation of specialised teaching material for an audience with varied backgrounds and experience, and a widespread distribution of students and lecturers in different countries and with significant differences in ICT resources. These courses have combined tutorials, video-conferences, forums, chats, a media centre with video and podcast, and other resources to allow a close follow-up of the students' progress and strengthen the learning process. A specialised database of information within the "América Latina Genera" project has also been used intensively. Even though the building of capacity has been important, the emphasis of the courses has been on the practical application of projects in the students' work environment and in other real situations. The first course took place between June and December 2008 and consisted of a combination of on-site and distance education. The 15 students that registered the course included officials of local and central government institutions, private consultants, university staff and members of non-governmental organisations. Lecturers from the United States Geological Survey and the International Centre for Geohazards broadcasted videoconferences from the United States and Norway, respectively. The second course started in November 2008 and is scheduled to finish in February 2009. This course has been fully developed using distance education

  19. Total System Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yong Soo; Kang, Chul Hyung; Lee, Youn Myoung; Han, Ji Woong; Choi, Jong Won; Hahn, Pil Soo; Park, Jeong Hwa; Jeong, Mi Seon

    2007-06-15

    Based on the KAERI FEP list developed through the previous studies, the KAERI FEP Encyclopedia has been developed. Current version is 1.0 which includes all relevant FEPs to compose of two references and all alternative scenarios. Many interaction FEPs between scenario defining FEP(SDF) are created throughout the study. FEPs are classified into many Integrated FEP(IFEP) which eventually become the elements of the RES matrix. The FEAS program one of the component of the KAERI's CYPRUS information system is added to develop the FEP, RES, AC, AMF and finally scenarios. It assists to create transparent way to deal with assessment from the stage of the planning of the R and D to the final stage of the external audit and regulatory body review. Even though MASCOT-K and compartment analysis codes such as AMBER, GoldSim and Ecolego are excellent for TSPA they by in heritage possess a certain limitation especially to identify a proper migration cross sectional area when a relatively big component intersects with a tiny one such as a fracture. It is truly 3D phenomena in nature. MDPSA code is developed which is expected to overcome limitations in compartment models while successfully deals with natural disruptive events. The R and D target for the TSPA is to develop the sufficient scenarios and their variation cases to understand the safety of KRS in every possible aspect. For this, reference scenarios, alternative scenarios covering engineered barrier failure and natural events are developed and assessed respectively for around 100 cases. The stylized template to assess the Korean reference biosphere is developed using the AMBER. Three critical groups, agricultural, freshwater and marine water fishing groups are identified to assess the DCF following the guidelines of ICRP. Based on the QA principles of T2R3, the web based QA system is developed using the procedures in the USNRC 10CFR50 Appendix B. The QA system is combined with the PAID and FEAS to create the comprehensive

  20. Total System Performance Assessment

    International Nuclear Information System (INIS)

    Hwang, Yong Soo; Kang, Chul Hyung; Lee, Youn Myoung; Han, Ji Woong; Choi, Jong Won; Hahn, Pil Soo; Park, Jeong Hwa; Jeong, Mi Seon

    2007-06-01

    Based on the KAERI FEP list developed through the previous studies, the KAERI FEP Encyclopedia has been developed. Current version is 1.0 which includes all relevant FEPs to compose of two references and all alternative scenarios. Many interaction FEPs between scenario defining FEP(SDF) are created throughout the study. FEPs are classified into many Integrated FEP(IFEP) which eventually become the elements of the RES matrix. The FEAS program one of the component of the KAERI's CYPRUS information system is added to develop the FEP, RES, AC, AMF and finally scenarios. It assists to create transparent way to deal with assessment from the stage of the planning of the R and D to the final stage of the external audit and regulatory body review. Even though MASCOT-K and compartment analysis codes such as AMBER, GoldSim and Ecolego are excellent for TSPA they by in heritage possess a certain limitation especially to identify a proper migration cross sectional area when a relatively big component intersects with a tiny one such as a fracture. It is truly 3D phenomena in nature. MDPSA code is developed which is expected to overcome limitations in compartment models while successfully deals with natural disruptive events. The R and D target for the TSPA is to develop the sufficient scenarios and their variation cases to understand the safety of KRS in every possible aspect. For this, reference scenarios, alternative scenarios covering engineered barrier failure and natural events are developed and assessed respectively for around 100 cases. The stylized template to assess the Korean reference biosphere is developed using the AMBER. Three critical groups, agricultural, freshwater and marine water fishing groups are identified to assess the DCF following the guidelines of ICRP. Based on the QA principles of T2R3, the web based QA system is developed using the procedures in the USNRC 10CFR50 Appendix B. The QA system is combined with the PAID and FEAS to create the comprehensive

  1. Total System Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yong Soo; Kang, Chul Hyung; Lee, Youn Myoung; Han, Ji Woong; Choi, Jong Won; Hahn, Pil Soo; Park, Jeong Hwa; Jeong, Mi Seon

    2007-06-15

    Based on the KAERI FEP list developed through the previous studies, the KAERI FEP Encyclopedia has been developed. Current version is 1.0 which includes all relevant FEPs to compose of two references and all alternative scenarios. Many interaction FEPs between scenario defining FEP(SDF) are created throughout the study. FEPs are classified into many Integrated FEP(IFEP) which eventually become the elements of the RES matrix. The FEAS program one of the component of the KAERI's CYPRUS information system is added to develop the FEP, RES, AC, AMF and finally scenarios. It assists to create transparent way to deal with assessment from the stage of the planning of the R and D to the final stage of the external audit and regulatory body review. Even though MASCOT-K and compartment analysis codes such as AMBER, GoldSim and Ecolego are excellent for TSPA they by in heritage possess a certain limitation especially to identify a proper migration cross sectional area when a relatively big component intersects with a tiny one such as a fracture. It is truly 3D phenomena in nature. MDPSA code is developed which is expected to overcome limitations in compartment models while successfully deals with natural disruptive events. The R and D target for the TSPA is to develop the sufficient scenarios and their variation cases to understand the safety of KRS in every possible aspect. For this, reference scenarios, alternative scenarios covering engineered barrier failure and natural events are developed and assessed respectively for around 100 cases. The stylized template to assess the Korean reference biosphere is developed using the AMBER. Three critical groups, agricultural, freshwater and marine water fishing groups are identified to assess the DCF following the guidelines of ICRP. Based on the QA principles of T2R3, the web based QA system is developed using the procedures in the USNRC 10CFR50 Appendix B. The QA system is combined with the PAID and FEAS to create the

  2. The Total Force: Cultural Considerations for the Future of the Total Force Integration

    Science.gov (United States)

    2017-03-31

    address TFI as an organizational process or structure problem in which people, qualifications, and equipment, are objects that can be manipulated in...Merger and Cultural Change for Better Outcomes: The First Five Years of the New York State Office of Children and Family Services.” Child Welfare Vol...will take on the culture of the commander, [and therefore the commander must] make doing the right things easy and wrong [or] stupid things hard.”19

  3. Integral-preserving integrators

    International Nuclear Information System (INIS)

    McLaren, D I; Quispel, G R W

    2004-01-01

    Ordinary differential equations having a first integral may be solved numerically using one of several methods, with the integral preserved to machine accuracy. One such method is the discrete gradient method. It is shown here that the order of the method can be bootstrapped repeatedly to higher orders of accuracy. The method is illustrated using the Henon-Heiles system. (letter to the editor)

  4. Total quality management program planning

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, P.T.; Spence, K.

    1994-05-01

    As government funding grows scarce, competition between the national laboratories is increasing dramatically. In this era of tougher competition, there is no for resistance to change. There must instead be a uniform commitment to improving the overall quality of our products (research and technology) and an increased focus on our customers` needs. There has been an ongoing effort to bring the principles of total quality management (TQM) to all Energy Systems employees to help them better prepare for future changes while responding to the pressures on federal budgets. The need exists for instituting a vigorous program of education and training to an understanding of the techniques needed to improve and initiate a change in organizational culture. The TQM facilitator is responsible for educating the work force on the benefits of self-managed work teams, designing a program of instruction for implementation, and thus getting TQM off the ground at the worker and first-line supervisory levels so that the benefits can flow back up. This program plan presents a conceptual model for TQM in the form of a hot air balloon. In this model, there are numerous factors which can individually and collectively impede the progress of TQM within the division and the Laboratory. When these factors are addressed and corrected, the benefits of TQM become more visible. As this occurs, it is hoped that workers and management alike will grasp the ``total quality`` concept as an acceptable agent for change and continual improvement. TQM can then rise to the occasion and take its rightful place as an integral and valid step in the Laboratory`s formula for survival.

  5. Integrating the "TDA Army" into the "Total Army"

    National Research Council Canada - National Science Library

    Kubik, Doris

    1999-01-01

    .... Focusing primarily on the lack of management and control of TDA organizations, this paper identifies weaknesses in the current method of accounting for these units, reviews initiatives designed...

  6. Renin secretion and total body sodium: Pathways of integrative control

    DEFF Research Database (Denmark)

    Bie, Peter; Damkjaer, Mads

    2009-01-01

    to a spring/shock absorber set-up: Non-adaptive RAAS functions determine the new steady state position while TGF controls the rate of change. Recruitment of renin-secreting cells during sustained stimulation may be essential for chronic adaptation, although details of this afferent arteriolar cell plasticity...

  7. An Analysis of Total Force Integration in RED HORSE Organizations

    Science.gov (United States)

    2014-03-27

    limits the external validity—the ability to generalize findings (Shadish, Cook, and Campbell, 2002). Another relevant sampling technique is snowball ... sampling , which is acquiring new subjects from the recommendations of previous subjects. Snowball sampling is one type of purposive sampling because...31 Interview Sampling

  8. Integration of total quality management in the management of ...

    African Journals Online (AJOL)

    This study was occasioned by the phenomenon that the existential environment calls for improved managerial effectiveness and a qualitative transformation of the academy. Hence the author set out to examine this stance at Makerere University, Mbarara University of Science and Technology and Uganda Martyrs University ...

  9. A business case for on-site generation: The BD biosciences pharmingen project

    Energy Technology Data Exchange (ETDEWEB)

    Firestone, Ryan; Creighton, Charles; Bailey, Owen; Marnay, Chris; Stadler, Michael

    2003-09-01

    Deregulation is haltingly changing the United States electricity markets. The resulting uncertainty and/or rising energy costs can be hedged by generating electricity on-site and other benefits, such as use of otherwise wasted heat, can be captured. The Public Utility Regulatory Policy Act (PURPA) of 1978 first invited relatively small-scale generators ({ge} 1 MW) into the electricity market. The advent of efficient and reliable small scale and renewable equipment has spurred an industry that has, in recent years, made even smaller (business scale) electricity generation an economically viable option for some consumers. On-site energy capture and/or conversion, known as distributed energy resources (DER), offers consumers many benefits, such as economic savings and price predictability, improved reliability, control over power quality, and emissions reductions. Despite these benefits, DER adoption can be a daunting move to a customer accustomed to simply paying a monthly utility bill. San Diego is in many ways an attractive location for DER development: It has high electricity prices typical of California and a moderate climate i.e. energy loads are consistent throughout the year. Additionally, the price shock to San Diego Gas and Electric (SDG&E) customers during the summer of 2000 has interested many in alternatives to electricity price vulnerability. This report examines the business case for DER at the San Diego biotechnology supply company, BD Biosciences Pharmingen, which considered DER for a building with 200-300 kW base-load, much of which accommodates the refrigerators required to maintain chemicals. Because of the Mediterranean climate of the San Diego area and the high rate of air changes required due to on-site use of chemicals, modest space heating is required throughout the year. Employees work in the building during normal weekday business hours, and daily peak loads are typically about 500 kW.

  10. Lessons Learned from the On-Site Disposal Facility at Fernald Closure Project

    International Nuclear Information System (INIS)

    Kumthekar, U.A.; Chiou, J.D.

    2006-01-01

    The On-Site Disposal Facility (OSDF) at the U.S. Department of Energy's (DOE) Fernald Closure Project near Cincinnati, Ohio is an engineered above-grade waste disposal facility being constructed to permanently store low level radioactive waste (LLRW) and treated mixed LLRW generated during Decommissioning and Demolition (D and D) and soil remediation performed in order to achieve the final land use goal at the site. The OSDF is engineered to store 2.93 million cubic yards of waste derived from the remediation activities. The OSDF is intended to isolate its LLRW from the environment for at least 200 years and for up to 1,000 years to the extent practicable and achievable. Construction of the OSDF started in 1997 and waste placement activities will complete by the middle of April 2006 with the final cover (cap) placement over the last open cell by the end of Spring 2006. An on-site disposal alternative is considered critical to the success of many large-scale DOE remediation projects throughout the United States. However, for various reasons this cost effective alternative is not readily available in many cases. Over the last ten years Fluor Fernald Inc. has cumulated many valuable lessons learned through the complex engineering, construction, operation, and closure processes of the OSDF. Also in the last several years representatives from other DOE sites, State agencies, as well as foreign government agencies have visited the Fernald site to look for proven experiences and practices, which may be adapted for their sites. This paper present a summary of the major issues and lessons leaned at the Fernald site related to engineering, construction, operation, and closure processes for the disposal of remediation waste. The purpose of this paper is to share lessons learned and to benefit other projects considering or operating similar on-site disposal facilities from our successful experiences. (authors)

  11. WE-G-BRA-05: IROC Houston On-Site Audits and Parameters That Affect Performance

    Energy Technology Data Exchange (ETDEWEB)

    Kry, S; Dromgoole, L; Alvarez, P; Lowenstein, J; Molineu, A; Taylor, P; Followill, D [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To highlight the IROC Houston on-site dosimetry audit program, and to investigate the impact of clinical conditions on the frequency of errors/recommendations noted by IROC Houston. Methods: The results of IROC Houston on-site audits from 2000-present were abstracted and compared to clinical parameters, this included 409 institutions and 1020 linacs. In particular, we investigated the frequency of recommendations versus year, and the impact of repeat visits on the number of recommendations. We also investigated the impact on the number of recommendations of several clinical parameters: the number and age of the linacs, the linac/TPS combination, and the scope of the QA program. Results: The number of recommendations per institution (3.1 average) has shown decline between 2000 and present, although the number of recommendations per machine (0.89) has not changed. Previous IROC Houston site visits did not Result in fewer recommendations on a repeat visit, but IROC Houston tests have changed substantially during the last 15 years as radiotherapy technology has changed. There was no impact on the number of recommendations based on the number of machines at the institution or the age of a given machine. The fewest recommendations were observed for Varian-Eclipse combinations (0.71 recs/machine), while Elekta- Pinnacle combinations yielded the most (1.62 recs/machine). Finally, in the TG-142 era (post-2010), those institutions that had a QA recommendation (n=77) had significantly more other recommendations (1.83 per institution) than those that had no QA rec (n=12, 1.33 per institution). Conclusion: Establishing and maintaining a successful radiotherapy program is challenging and areas of improvement can routinely be identified. Clinical conditions such as linac-TPS combinations and the establishment of a good QA program impact the frequency of errors/deficiencies identified by IROC Houston during their on-site review process.

  12. WE-G-BRA-05: IROC Houston On-Site Audits and Parameters That Affect Performance

    International Nuclear Information System (INIS)

    Kry, S; Dromgoole, L; Alvarez, P; Lowenstein, J; Molineu, A; Taylor, P; Followill, D

    2015-01-01

    Purpose: To highlight the IROC Houston on-site dosimetry audit program, and to investigate the impact of clinical conditions on the frequency of errors/recommendations noted by IROC Houston. Methods: The results of IROC Houston on-site audits from 2000-present were abstracted and compared to clinical parameters, this included 409 institutions and 1020 linacs. In particular, we investigated the frequency of recommendations versus year, and the impact of repeat visits on the number of recommendations. We also investigated the impact on the number of recommendations of several clinical parameters: the number and age of the linacs, the linac/TPS combination, and the scope of the QA program. Results: The number of recommendations per institution (3.1 average) has shown decline between 2000 and present, although the number of recommendations per machine (0.89) has not changed. Previous IROC Houston site visits did not Result in fewer recommendations on a repeat visit, but IROC Houston tests have changed substantially during the last 15 years as radiotherapy technology has changed. There was no impact on the number of recommendations based on the number of machines at the institution or the age of a given machine. The fewest recommendations were observed for Varian-Eclipse combinations (0.71 recs/machine), while Elekta- Pinnacle combinations yielded the most (1.62 recs/machine). Finally, in the TG-142 era (post-2010), those institutions that had a QA recommendation (n=77) had significantly more other recommendations (1.83 per institution) than those that had no QA rec (n=12, 1.33 per institution). Conclusion: Establishing and maintaining a successful radiotherapy program is challenging and areas of improvement can routinely be identified. Clinical conditions such as linac-TPS combinations and the establishment of a good QA program impact the frequency of errors/deficiencies identified by IROC Houston during their on-site review process

  13. 75 FR 21353 - Intel Corporation, Fab 20 Division, Including On-Site Leased Workers From Volt Technical...

    Science.gov (United States)

    2010-04-23

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-73,642] Intel Corporation, Fab 20... of Intel Corporation, Fab 20 Division, including on-site leased workers of Volt Technical Resources... Precision, Inc. were employed on-site at the Hillsboro, Oregon location of Intel Corporation, Fab 20...

  14. 75 FR 76038 - Zach System Corporation a Subdivision of Zambon Company, SPA Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-07

    ... Subdivision of Zambon Company, SPA Including On-Site Leased Workers of Turner Industries and Go Johnson, La..., including on-site leased workers from Turner Industries and Go Johnson, La Porte, Texas. The Department's... investigation revealed that Zach System Corporation is a subdivision of Zambon Company, SPA, not Zach System SPA...

  15. 76 FR 16447 - ETHICON, a Subsidiary of Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary...

    Science.gov (United States)

    2011-03-23

    ... workers of ETHICON, A Johnson and Johnson Company, San Angelo, Texas, separated from employment on or... Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary Services, San Angelo, TX; Amended... of ETHICON, a subsidiary of Johnson & Johnson, including on-site leased workers from Kelly Temporary...

  16. 76 FR 27366 - CEVA Freight, LLC, Dell Logistics Division, Including On-Site Leased Workers From Prologistix...

    Science.gov (United States)

    2011-05-11

    ... Logistics Division, Including On-Site Leased Workers From Prologistix, Including Workers Whose Unemployment..., applicable to workers of CEVA Freight, LLC, Dell Logistics Division, including on-site leased workers from... workers employed at CEVA Freight, LLC, Dell Logistics Division, Winston-Salem, North Carolina who were...

  17. 75 FR 76037 - HAVI Logistics, North America a Subsidiary of HAVI Group, LP Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-07

    ... Logistics, North America a Subsidiary of HAVI Group, LP Including On-Site Leased Workers of Express Personnel Services and the La Salle Network, Bloomingdale, IL; Havi Logistics, North America, Lisle, IL..., applicable to workers of HAVI Logistics, North America, a subsidiary of HAVI Group, LP, including on-site...

  18. 75 FR 38128 - Ceva Freight, LLC, Dell Logistics Division, Including On-Site Leased Workers From Prologistix and...

    Science.gov (United States)

    2010-07-01

    ... Logistics Division, Including On-Site Leased Workers From Prologistix and Employment Staffing Solutions... 19, 2010, applicable to workers of CEVA Freight, LLC, Dell Logistics Division, including on-site..., North Carolina location of CEVA Freight, LLC, Dell Logistics Division. The Department has determined...

  19. 75 FR 11921 - Heritage Aviation, Ltd., Including On-Site Leased Workers From Global Technical Services and...

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,924] Heritage Aviation, Ltd., Including On-Site Leased Workers From Global Technical Services and Global, Inc. (Global Employment... from Heritage Aviation, Ltd, including on-site leased workers from Global Technical Services, Grand...

  20. 76 FR 61741 - Bmc Software, Inc. Including On-Site Leased Workers From COMSYS ITS Including Remote Workers...

    Science.gov (United States)

    2011-10-05

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-74,540] Bmc Software, Inc... November 23, 2010, applicable to workers of BMC Software, Inc., including on-site leased workers from... BMC Software, inc., including on-site leased workers from Comsys ITS, and including remote workers...

  1. 76 FR 50272 - West, A Thomson Reuters Business, Thomson Reuters Legal Division, Including On-Site Leased...

    Science.gov (United States)

    2011-08-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,099] West, A Thomson Reuters Business, Thomson Reuters Legal Division, Including On-Site Leased Workers From Adecco, Albuquerque, New... former workers of West, A Thomson Reuters Business, Thomson Reuters Legal Division, including On-Site...

  2. 78 FR 2287 - Daimler Buses North America, Inc., a Subsidiary of Daimler North America Corp, Including On-Site...

    Science.gov (United States)

    2013-01-10

    ... subsidiary of Daimler North America Corp., including on-site leased workers from Noramtec, First Choice... America, Inc., a Subsidiary of Daimler North America Corp, Including On-Site Leased Workers From Noramtec, First Choice Staffing, Staff Works, and Mr. Santo Lamarco From Wurth Revcar Fasteners, Inc., Oriskany...

  3. 75 FR 453 - FLSMidth, Inc., Cement Division, Product Engineering, Including On-Site Leased Workers of Aerotek...

    Science.gov (United States)

    2010-01-05

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,048] FLSMidth, Inc., Cement..., Inc., Cement Division, Product Engineering, including on-site leased workers of Aerotek Contract.... were also employed on-site at FLSmidth, Inc., Cement Division, Product Engineering, Bethlehem...

  4. 75 FR 45166 - Jeld-Wen, Inc., Hawkins Window Division, Including On-Site Leased Workers of Nicolet Staffing...

    Science.gov (United States)

    2010-08-02

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,014] Jeld-Wen, Inc., Hawkins Window Division, Including On-Site Leased Workers of Nicolet Staffing, Hawkins, WI; Notice of Negative...., Hawkins Window Division, including on-site leased workers of Nicolet Staffing, Hawkins, Wisconsin. Signed...

  5. 78 FR 21155 - Eastman Kodak Company, IPS-Dayton Location, Including On-site Leased Workers From Adecco, Dayton...

    Science.gov (United States)

    2013-04-09

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,387] Eastman Kodak Company, IPS--Dayton Location, Including On-site Leased Workers From Adecco, Dayton, Ohio; Notice of... and former workers of Eastman Kodak Company, IPS--Dayton Location, including on-site leased workers...

  6. 77 FR 21588 - Hart and Cooley, Inc., A Subsidiary of Tomkins, PLC Including On-Site Leased Workers from...

    Science.gov (United States)

    2012-04-10

    ... Subsidiary of Tomkins, PLC Including On- Site Leased Workers from Reliable, Masiello Employment Services..., applicable to workers of Hart and Cooley, Inc., a subsidiary of Tomkins, PLC, including on-site leased... workers. Based on these findings, the Department is amending this certification to include workers leased...

  7. 77 FR 3499 - Sony Electronics, Inc., Including On-Site Leased Workers From Selectremedy Park Ridge, NJ...

    Science.gov (United States)

    2012-01-24

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-71,501M] Sony Electronics, Inc... Electronics, Inc., SEL Headquarters, including on-site leased workers of SelectRemedy, StaffMark, and Payrolling.com , San Diego, California (TA-W-71,501); Sony Electronics, Inc., including on-site leased...

  8. 75 FR 5147 - Acushnet Company a Subsidiary of Fortune Brands Including On-Site Leased Workers From Olsten...

    Science.gov (United States)

    2010-02-01

    ...,763B] Acushnet Company a Subsidiary of Fortune Brands Including On-Site Leased Workers From Olsten Staffing Services Fairhaven, MA; Acushnet Company a Subsidiary of Fortune Brands Including On-Site Leased Workers From Olsten Staffing Services New Bedford, MA; Acushnet Company a Subsidiary of Fortune Brands...

  9. 76 FR 2145 - International Paper Company, Franklin Pulp & Paper Mill, Including On-Site Leased Workers From...

    Science.gov (United States)

    2011-01-12

    ... Company, Franklin Pulp & Paper Mill, Including On-Site Leased Workers From Railserve, Franklin, VA..., applicable to workers and former workers of International Paper Company, Franklin Pulp & Paper Mill, Franklin... follows: All workers International Paper Company, Franklin Pulp & Paper Mill, including on-site leased...

  10. 78 FR 8587 - American Showa, Inc.; Blanchester Plant, Including On-Site Leased Workers From Adecco and Sims...

    Science.gov (United States)

    2013-02-06

    ....; Blanchester Plant, Including On-Site Leased Workers From Adecco and Sims Bros., Inc.; Blanchester, OH; Amended... workers from Sims Bros., Inc. were working on-site at the subject firm during the relevant period and that the services supplied by Sims Bros., Inc. were related to the production of gear boxes (and parts...

  11. 78 FR 61389 - Sanyo Solar of Oregon, LLC, Wafer Slicing and Quality Control Operations, Including On-Site...

    Science.gov (United States)

    2013-10-03

    ..., LLC, Wafer Slicing and Quality Control Operations, Including On-Site Leased Workers From Brown and... Quality Control Operations, Salem, Oregon, including on-site leased workers from Brown and Dunton, Inc... and included workers who supplied quality control and support functions. The company reports that...

  12. 78 FR 12358 - Cardinal Health, Financial Shared Services West, Including On-Site Leased Workers From Aerotek...

    Science.gov (United States)

    2013-02-22

    ... office financial services from India and the Philippines. Based on these findings, the Department is..., Financial Shared Services West, Including On- Site Leased Workers From Aerotek, eXcel Staffing, Experis..., applicable to workers of Cardinal Health, Financial Shared Services West, including on-site leased workers...

  13. 77 FR 62535 - Hydro Aluminum North America, Inc., Midwest Region, Including On-Site Leased Workers From...

    Science.gov (United States)

    2012-10-15

    ... Aluminum North America, Inc., Midwest Region, Including On- Site Leased Workers From Employment Group, Aerotek, and Manpower, Kalamazoo, Michigan; Hydro Aluminum North America, Inc., Midwest Region, Including... Aluminum North America, Inc., Kalamazoo, Michigan. The subject worker group includes on-site leased workers...

  14. The use of on-site Project Officers by a nuclear regulatory body

    International Nuclear Information System (INIS)

    Beare, J.W.

    1977-01-01

    In Canada consideration of applications for licensing nuclear installations is entrusted to the Reactor Safety Advisory Committee within the Atomic Energy Control Board (AECB). The licensing procedure is conducted in three stages (site approval, construction licence, operating licence). In order to control construction and operation of nuclear installations Project Officers are assigned to each particular installation. The policy of AECB is to send these officers on site several months before the reactor reaches criticality; and during reactor operation. This system clearly provides great practical advantages. (NEA) [fr

  15. Description of INR-Pitesti own strategy for on site radioactive solid waste storage concepts

    International Nuclear Information System (INIS)

    Tuturici, I.L.; Toma, V.; Bujoreanu, D.; Prava, M.

    1993-01-01

    The Post Irradiation Examination Laboratory (PIEL) produces and will produce the majority of institute's alpha-contaminated solid radioactive waste, generated by the process of examination of irradiated CANDU-600 type nuclear fuel. The wastes will be divided into three categories: low-level, medium-level, and high-level general process trash (LLGPT, MLGPT, and HLGPT). The paper describes the strategy adopted for immobilization, conditioning and on-site long-term storage of these wastes. The proposed strategy is based on the best experience acquired by other nuclear centers, confronted with same problems. (Author)

  16. Droplet-counting Microtitration System for Precise On-site Analysis.

    Science.gov (United States)

    Kawakubo, Susumu; Omori, Taichi; Suzuki, Yasutada; Ueta, Ikuo

    2018-01-01

    A new microtitration system based on the counting of titrant droplets has been developed for precise on-site analysis. The dropping rate was controlled by inserting a capillary tube as a flow resistance in a laboratory-made micropipette. The error of titration was 3% in a simulated titration with 20 droplets. The pre-addition of a titrant was proposed for precise titration within an error of 0.5%. The analytical performances were evaluated for chelate titration, redox titration and acid-base titration.

  17. On-site concrete cask storage system for spent nuclear fuel

    International Nuclear Information System (INIS)

    Craig, P.A.; Haelsig, R.T.; Kent, J.D.; Schmoker, D.S.

    1989-01-01

    A method is described of storing spent nuclear fuel assemblies including the steps of: transferring the fuel assemblies from a spent-fuel pool to a moveable concrete storage cask located outside the spent-fuel pool; maintaining a barrier between the fuel and the concrete in the cask to prevent contamination of the concrete by the fuel; maintaining the concrete storage cask containing the spent-fuel on site at the reactor complex for some predetermined period; transferring the fuel assemblies from the concrete storage cask to a shipping container; and, recycling the concrete storage cask

  18. Study of Some Innovant Reactors without on- Site Refueling with Triso and Cermet Fuel

    OpenAIRE

    A.Chetaine; A. Benchrif; H. Amsil; V. Kuznetsov; Y. Shimazu

    2012-01-01

    The evaluation of unit cell neutronic parameters and lifetime for some innovant reactors without on sit-refuling will be held in this work. the behavior of some small and medium reactors without on site refueling with triso and cermet fuel. For the FBNR long life except we propose to change the enrichment of the Cermet MFE to 9%. For the AFPR reactor we can see that the use of the Cermet MFE can extend the life of this reactor but to maintain the same life period for AFPR...

  19. On-site control of 900 and 1300 MWe nuclear reactors control rod assemblies

    International Nuclear Information System (INIS)

    Lacroix, R.; Lebuffe, C.; Bour, D.; Pasquier, T.

    1990-01-01

    To measure the external wear of clads of the RCCA rodlets in both 900 and 1300 MWe P.W.R., two on site examination tools was developed by FRAGEMA. They have been used in 42 inspections between 1986 and 1989. The examination is performed in two successive phases: - longitudinal detection of wear by eddy currents, - characterization of wear by ultrasonic profilometry. Moreover, at the instance of E.D.F., an equipment is developing by INTERCONTROLE. These measurement tools allow a suitable monitoring system adapted to the phenomenon kinetics [fr

  20. On-site emergency intervention plan for nuclear accident situation at SCN-Pitesti TRIGA Reactor

    International Nuclear Information System (INIS)

    Margeanu, S.; Oprea, I.

    2008-01-01

    A 14 MW TRIGA research reactor is operated on the Institute for Nuclear Research site. In the event of a nuclear accident or radiological emergency that may affect the public the effectiveness of protective actions depends on the adequacy of intervention plans prepared in advance. Considerable planning is necessary to reduce to manageable levels the types of decisions leading to effective responses to protect the public in such an event. The essential structures of our on-site, off-site and county emergency intervention plan and the correlation between emergency intervention plans are presented. (authors)

  1. Estimations of On-site Directional Wave Spectra from Measured Ship Responses

    DEFF Research Database (Denmark)

    Nielsen, Ulrik Dam

    2006-01-01

    include an quivalence of energy in the governing equations and, as regards the parametric concept, a frequency dependent spreading of the waves is introduced. The paper includes an extensive analysis of full-scale measurements for which the directional wave spectra are estimated by the two ship response......In general, two main concepts can be applied to estimate the on-site directional wave spectrum on the basis of ship response measurements: 1) a parametric method which assumes the wave spectrum to be composed by parameterised wave spectra, or 2) a non-parametric method where the directional wave...

  2. On-Site Fecal Sludge Treatment with the Anaerobic Digestion Pasteurization Latrine

    OpenAIRE

    Forbis-Stokes, Aaron A.; O'Meara, Patrick F.; Mugo, Wangare; Simiyu, Gelas M.; Deshusses, Marc A.

    2016-01-01

    Abstract The Anaerobic Digestion Pasteurization Latrine (ADPL) is a self-contained and energy neutral on-site sanitation system using anaerobic digestion of fecal sludge to generate biogas and then uses the biogas to pasteurize the digester effluent at 65?75?C to produce a safe effluent that can be reused locally as a fertilizer. Two ADPL systems were installed on residential plots with 17 and 35 residents in a peri-urban area outside of Eldoret, Kenya. Each system comprised three toilets bui...

  3. Chemical and microbiological investigations on mineral-oil contaminated soils following on-site regeneration measures

    International Nuclear Information System (INIS)

    Hollerbach, A.; Teschner, M.; Bosecker, K.; Wehner, H.; Kassner, H.

    1992-01-01

    In the site of a former petroleum refinery, where bombing during the second World War has caused in part deep-down contamination of the ground with petroleum and its products, a pilot study with five on-site biological treatment beds was carried through by different firms with the aim to reduce the hydrocarbon content of the soil to 1 gramme per kilogramme of dry weight. Thus, good comparability of the different regeneration measures was given. Sampling was done at the end of the regeneration experiments by obtaining an average sample. (orig.) [de

  4. Recommended criteria for the evaluation of on-site nuclear power plant emergency exercises

    International Nuclear Information System (INIS)

    Lafortune, J.F.

    1997-01-01

    A review of existing Canadian and International emergency exercise evaluation criteria and approaches has been conducted. Based on the results of the review, criteria are proposed for the evaluation of on-site emergency exercises for Canadian nuclear power stations. The proposed criteria are performance-based. They are comprehensive, yet remain adaptable to all stations and accident scenarios. They are primarily aimed at radiological emergency exercises, but are entirely applicable to fire or other conventional exercises. This report also addresses evaluation preparation and methodology. (author). 21 refs., 6 tabs

  5. On-site underground background measurements for the KASKA reactor-neutrino experiment

    International Nuclear Information System (INIS)

    Furuta, H.; Sakuma, K.; Aoki, M.; Fukuda, Y.; Funaki, Y.; Hara, T.; Haruna, T.; Ishihara, N.; Katsumata, M.; Kawasaki, T.; Kuze, M.; Maeda, J.; Matsubara, T.; Matsumoto, T.; Miyata, H.; Nagasaka, Y.; Nakagawa, T.; Nakajima, N.; Nitta, K.; Sakai, K.; Sakamoto, Y.; Suekane, F.; Sumiyoshi, T.; Tabata, H.; Tamura, N.; Tsuchiya, Y.

    2006-01-01

    On-site underground background measurements were performed for the planned reactor-neutrino oscillation experiment KASKA at Kashiwazaki-Kariwa nuclear power station in Niigata, Japan. A small-diameter boring hole was excavated down to 70m underground level, and a detector unit for γ-ray and cosmic-muon measurements was placed at various depths to take data. The data were analyzed to obtain abundance of natural radioactive elements in the surrounding soil and rates of cosmic muons that penetrate the overburden. The results will be reflected in the design of the KASKA experiment

  6. Field study of the composition of greywater and comparison of microbiological indicators of water quality in on-site systems.

    Science.gov (United States)

    Leonard, Margaret; Gilpin, Brent; Robson, Beth; Wall, Katrina

    2016-08-01

    Thirty on-site greywater systems were sampled to determine greywater characteristics and practices in the field. Kitchen greywater was present at eight sites and urine was included at seven sites. These non-traditional sources resulted in significantly higher concentrations of enterococci and 5-day biochemical oxygen demand (BOD5) in greywater. Even with the removal of these sources, the concentrations of microbial indicators indicated high levels of contamination could occur across all greywater sources, including "light" greywater. Using multiple microbial indicators showed that all samples had the potential for faecal contamination. Bacteroidales markers were confirmed in treated greywater and in each greywater source, highlighting the potential for human faecal contamination. Although Escherichia coli was absent in treated greywater recycled to the house, other microbial indicators were present; hence, caution is required in using E. coli concentrations as the sole indicator of microbiological water quality. High BOD5 or total suspended solid concentrations exceeded the levels recommended for effective disinfection. Subsurface irrigation, which is assumed to provide a five-log reduction in exposure, is a suitable reuse option for non-disinfected greywater. Only half the occupants had a good understanding of their greywater systems and 25 % of systems were poorly maintained. Elevated microbial indicator contamination of greywater sludge is a potential hazard during maintenance.

  7. Assessment of surgical and obstetrical care at 10 district hospitals in Ghana using on-site interviews.

    Science.gov (United States)

    Abdullah, Fizan; Choo, Shelly; Hesse, Afua A J; Abantanga, Francis; Sory, Elias; Osen, Hayley; Ng, Julie; McCord, Colin W; Cherian, Meena; Fleischer-Djoleto, Charles; Perry, Henry

    2011-12-01

    For most of the population in Africa, district hospitals represent the first level of access for emergency and essential surgical services. The present study documents the number and availability of surgical and obstetrical care providers as well as the types of surgical and obstetrical procedures being performed at 10 first-referral district hospitals in Ghana. After institutional review board and governmental approval, a study team composed of Ghanaian and American surgeons performed on-site surveys at 10 district hospitals in 10 different regions of Ghana in August 2009. Face-to-face interviews were conducted documenting the numbers and availability of surgical and obstetrical personnel as well as gathering data relating to the number and types of procedures being performed at the facilities. A total of 68 surgical and obstetrical providers were interviewed. Surgical and obstetrical care providers consisted of Medical Officers (8.5%), nurse anesthetists (6%), theatre nurses (33%), midwives (50.7%), and others (4.5%). Major surgical cases represented 37% of overall case volumes with cesarean section as the most common type of major surgical procedure performed. The most common minor surgical procedures performed were suturing of lacerations or episiotomies. The present study demonstrates that there is a substantial shortage of adequately trained surgeons who can perform surgical and obstetrical procedures at first-referral facilities. Addressing human resource needs and further defining practice constraints at the district hospital level are important facets of future planning and policy implementation. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Agreement between self-reports and on-site inspections of compliance with a workplace smoking ban.

    Science.gov (United States)

    Verdonk-Kleinjan, Wendy M I; Rijswijk, Pieter C P; Candel, Math J J M; de Vries, Hein; Knibbe, Ronald A

    2012-09-01

    This study compares self-reports on compliance with a workplace smoking ban with on-site inspections of the same workplace, in the Netherlands, to assess the validity of self-reported compliance by employees. A total of 360 companies had participated in the telephone survey (in October and November 2006) and were also visited by inspectors directly after the survey to establish compliance. The sampling frame included companies with 5 or more employees, stratified according to the number of employees and type of economic activity. We calculated the agreement, the under- or overestimation and the predictive values, and explored nonresponse research. The percent agreement on compliance between the two measures was 77.5%, the McNemar test was not significant, and the agreement coefficient with first order correction was .68, indicating moderately strong agreement. Furthermore, the results indicate a slight overestimation of compliance. Concerning the predictive values, we found most variance among the self-reported noncompliance: 55.2% of those reporting noncompliance did in fact comply. This study allows to conclude that self-reports on compliance with a workplace smoking ban are largely valid and that social desirability is negligible. For agencies enforcing the workplace smoking ban, these results indicate that a strategy to identify noncompliance among responding companies might be useful. Moreover, such a strategy reduces the burden of inspecting among complying companies.

  9. Do On-site Mental Health Professionals Change Pediatricians’ Responses to Children’s Mental Health Problems?

    Science.gov (United States)

    Horwitz, Sarah McCue; Storfer-Isser, Amy; Kerker, Bonnie D.; Szilagyi, Moira; Garner, Andrew S.; O’Connor, Karen G.; Hoagwood, Kimberly E.; Green, Cori M.; Foy, Jane M.; Stein, Ruth E.K.

    2016-01-01

    Objective The objectives were to: assess the availability of on-site mental health professionals (MHP) in primary care; examine practice/pediatrician characteristics associated with on-site MHPs; and determine whether presence of on-site MHPs is related to pediatricians’ co-managing or more frequently identifying, treat/managing or referring MH problems. Methods Analyses included AAP members who participated in an AAP Periodic Survey in 2013 and who practiced general pediatrics (N=321). Measures included socio-demographics, practice characteristics, questions on about on-site MHPs, co-management of MH problems and pediatricians’ behaviors in response to 5 prevalent MH problems. Weighted univariate, bivariate and multivariable analyses were performed. Results Thirty-five percent reported on-site MHPs. Practice characteristics (medical schools/universities/HMOs, <100 visits/week, <80% of patients privately insured), and interactions of practice location (urban) with visits and patient insurance, were associated with on-site MHPs. There was no overall association between co-location and co-management or whether pediatricians usually identified, treat/managed or referred 5 common child MH problems. Among the subset of pediatricians who reported co-managing there was an association with co-management when the on-site MHP was a child psychiatrist, SA counselor, or social worker. Conclusions On-site MHPs are more frequent in settings where low-income children are served and where pediatricians train. Pediatricians who co-manage MH problems are more likely to do so when the on-site MHP is a child psychiatrist, SA counselor, or social worker. Overall, on-site MHPs were not associated with co-management or increased likelihood of pediatricians identifying, treating/managing, or referring children with 5 common child MH problems. PMID:27064141

  10. Interaction of on-site and near real time measured turbidity and enzyme activity in stream water.

    Science.gov (United States)

    Stadler, Philipp; Farnleitner, Andreas H.; Zessner, Matthias

    2013-04-01

    On-site and on-line systems that provide an integrated surveillance of physicochemical and microbiological parameters gain significance in water quality monitoring. Particular relating to diffuse pollution from agricultural areas and use-orientated protection of waters the detection of faecal pollution is a fundamental part. For the near real time and on-site detection of microbiological faecal pollution of water, the beta-D- Glucuronidase (GLUC) enzymatic activity has been suggested as a surrogate parameter. Due to possible short measure intervals of three hours, this method has high potential as a water quality monitoring tool. While cultivation based standard determination takes more than one working day (Cabral 2010) the potential advantage of detecting the GLUC activity is the high temporal measuring resolution. Yet, there is still a big gap of knowledge on the sensitivity and specificity concerning the faecal indication capacity of GLUC in relation to standard assays (Cabral 2010). Interference effects of physicochemical parameters on the enzymatic activity respectively fluorescence have been discussed (Molina-Munoz et al. 2007; Tryland and Fiksdal 1998, Biswal et al. 2003). Results from a monitoring of a rivulet in an agricultural catchment in Lower Austria (HOAL - Hydrological Open Air Laboratory) are presented here. The HOAL offers technical resources that allow measurements at high temporal and spatial resolution and to apply various hydrological methods in one catchment. Two automated enzymatic measuring devices (Coliguard, mbOnline, Austria) and physicochemical in-stream measurements are used, as well as in-stream spectroscopy (spectrolyser, s::can, Austria). Accuracy of both enzymatic measuring devices is compared through diverse hydrological and seasonal conditions. Reference analyses by cultivation based determination were performed. Data from Coliguard devices is combined with physicochemical and spectroscopy data to gain information about the

  11. Incapacidad laboral total

    Directory of Open Access Journals (Sweden)

    Orlando Díaz Tabares

    1997-04-01

    Full Text Available Se realizó un estudio longitudinal, descriptivo y retrospectivo con el objetivo de conocer el comportamiento de la incapacidad permanente para el trabajo en el municipio "San Cristóbal" durante el decenio 1982-1991, y se aplicó el método de encuesta por el que se recogieron datos que fueron extraídos del modelo oficial de peritaje médico laboral y de la entrevista con el peritado. Los resultados fueron plasmados en tablas de contingencias donde se relacionan las variables por cada año estudiado, y se aplicó la prueba estadística de chi cuadrado. El número de individuos dictaminados con incapacidad laboral total fue de 693; predominó en reportes el año 1988 con 114 casos y muy discretamente el sexo femenino sobre el masculino, el grupo etáreo de 45 a 54 años con 360 casos y la artrosis como entidad valorada por ortopedia, con análisis estadísticos significativos. No resultó estadísticamente significativo, el predominio de la hipertensión arterial sistémica entre las entidades valoradas por la especialidad de medicina interna como causas de incapacidad laboral. Fue muy significativa la variación del número de dictaminados por la comisión en cada uno de los años estudiados y que el porcentaje de ellos que se encontraban realizando trabajos que demandan esfuerzo físico de moderado a intenso al momento de aplicar la encuesta, ascendió al 64,9.A longitudinal, descriptive and retrospective study was conducted in order to know the behavior of permanent labor disability at the municipality of San Cristóbal during 1982-1991. A survey was done to collect data taken from the official model of medical inspections and from the interview with the disabled worker. The results were shown in contingency tables where the variables are related by every year studied. The chi square statistical test was applied. The number of individuals with labor disability was 693. As for reports, the year 1988 predominated with 114. There was a discreet

  12. Design characteristics of EU-APR1400 on-site power system

    International Nuclear Information System (INIS)

    Kim, D.H.; Kim, Y.S.; Kim, Y.S.

    2014-01-01

    In the global nuclear market, US and European design requirements have been largely used to develop the design of nuclear power plants(NPPs). The APR1400 design was developed on the basis of US regulatory guide and EPRI utility requirements document(URD). In order to enlarge the export market of APR1400, KHNP (Korea Hydro & Nuclear Power Co., Ltd) has developed the EU-APR1400 design which complies with the European nuclear design requirements. In this paper, the design characteristics of EU-APR1400 on-site power system developed according to the European design requirements of electrical power system are described. The European main design requirements of electrical power system involve 50 Hz rated frequency, 400/110 kV grid voltage, the application of the diversity and the redundancy, and so on. The EU-APR1400 on-site power system has been developed on the basis of these requirements. The representative designs include the redundancy, diversity, independence design, the emergency power supply design, the design for providing electrical power to the dedicated severe accident systems, and the design for European grid requirements. (author)

  13. On-site Labour Productivity of New Zealand Construction Industry: Key Constraints and Improvement Measures

    Directory of Open Access Journals (Sweden)

    Serdar Durdyev

    2011-09-01

    Full Text Available Productivity is key to the survival and growth of any organisation, industry or nation. Some factors constrain the achievement of the set project objectives in the New Zealand building and construction industry and are responsible for the reported steady decline of productivity and performance. This study aims to identify the key constraints to on-site labour productivity and improvement measures. Using the descriptive survey method, views of some project managers, contractors and subcontractors in New Zealand were canvassed via pilot interviews and questionnaire surveys at the qualitative and quantity data gathering stages, respectively. Multi-attribute technique was used to analyse the quantitative data. Results showed that the key external constraints to on-site labour productivity comprise, in order of decreasing impact, statutory compliance, unforeseen events and wider external dynamics. The internal constraints, which contribute 67 percent of the onsite productivity issues, comprise reworks, level of skill and experience of the workforce, adequacy of method of construction, buildability issues, and inadequate supervision and coordination. . The factors underlying each broad category of external and internal constraints are reported. The relative levels of impact of the identified constraints are expected to guide the project team in addressing the constraints in a cost-effective manner.

  14. On-site storage of high level nuclear waste: Attitudes and perceptions of local residents

    International Nuclear Information System (INIS)

    Bassett, G.W. Jr.; Jenkins-Smith, H.C.; Silva, C.

    1996-01-01

    No public policy issue has been as difficult as high-level nuclear waste. Debates continue regarding Yucca Mountain as a disposal site, and - more generally - the appropriateness of geologic disposal and the need to act quickly. Previous research has focused on possible social, political, and economic consequences of a facility in Nevada. Impacts have been predicted to be potentially large and to emanate mainly from stigmatization of the region due to increased perceptions of risk. Analogous impacts from leaving waste at power plants have been either ignored or assumed to be negligible. This paper presents survey results on attitudes of residents in three countries where nuclear waste is currently stored. Topics include perceived risk, knowledge of nuclear waste and radiation, and impacts on jobs, tourism, and housing values from leaving waste on site. Results are similar to what has been reported for Nevada; the public is concerned about possible adverse effects from on-site storage of waste. 24 refs., 7 figs., 5 tabs

  15. Customer adoption of small-scale on-site power generation

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, Afzal S.; Marnay, Chris; Hamachi, Kristina S.; Rubio, F. Javier

    2001-04-01

    The electricity supply system is undergoing major regulatory and technological change with significant implications for the way in which the sector will operate (including its patterns of carbon emissions) and for the policies required to ensure socially and environmentally desirable outcomes. One such change stems from the rapid emergence of viable small-scale (i.e., smaller than 500 kW) generators that are potentially competitive with grid delivered electricity, especially in combined heat and power configurations. Such distributed energy resources (DER) may be grouped together with loads in microgrids. These clusters could operate semi-autonomously from the established power system, or macrogrid, matching power quality and reliability more closely to local end-use requirements. In order to establish a capability for analyzing the effect that microgrids may have on typical commercial customers, such as office buildings, restaurants, shopping malls, and grocery stores, an economic mod el of DER adoption is being developed at Berkeley Lab. This model endeavors to indicate the optimal quantity and type of small on-site generation technologies that customers could employ given their electricity requirements. For various regulatory schemes and general economic conditions, this analysis produces a simple operating schedule for any installed generators. Early results suggest that many commercial customers can benefit economically from on-site generation, even without considering potential combined heat and power and reliability benefits, even though they are unlikely to disconnect from the established power system.

  16. Numerical and on-site experimental dynamic analysis of the Italian PEC fast reactor building

    International Nuclear Information System (INIS)

    Castoldi, A.; Muzzi, F.; Orsi, R.; Panzeri, P.; Pezzoli, P.; Ruggeri, G.; Martelli, A.; Masoni, P.; Brancati, V.

    1988-01-01

    On-site dynamic tests and three-dimensional numerical analysis have been performed by ISMES on behalf of ENEA on the building of the Italian PEC fast reactor test facility. These studies aimed at evaluating the safety margins in the PEC reactor seismic analysis and at providing data for the optimization of the PEC seismic monitoring system. The paper describes the on-site dynamic tests carried out using various excitation methods (two eccentric back-rotating-mass mechanical vibrator, blasting in bore-hole and hydraulic actuators at the building foundations). It highlights the purposes of the four tests campaigns performed at various construction stages and reports the main experimental results. In connection with the experimental tests, a detailed 3D finite element model was set up for fixed base analysis; from the results of the 3D model a simplified equivalent model of the structure was then derived for soil-structure interaction analysis. The mathematical model was validated and calibrated by using the results of the experimental dynamic tests. The main numerical results and the comparisons with the experimental data are presented. (author)

  17. The safeguards on-site laboratory at Sellafield. Five years operational experience

    Energy Technology Data Exchange (ETDEWEB)

    Duinslaeger, L.; Belle, P. van; Mayer, K.; Casteleyn, K.; Abousahl, S.; Daures, P.; Eberle, H.; Enright, T.; Guiot, A.; Hild, M.; Horta Domenech, J.; Lajarge, P.; Laurent, P.; Le Terrier, A.; Lynch, B.; Marucci, M.; Millet, S.; Ottmar, H.; Richir, P.; Street, S.; Vallet, P.; Zuleger, E. [European Commission, Karlsruhe (Germany). Inst. for Transuranium Elements

    2004-06-01

    The start of operation of the large reprocessing facilities led Euratom Safeguards to a new approach for verification analysis of samples taken at the facility: the installation of on-site laboratories. The availability of analytical capabilities for independent verification measurements at the site of these facilities offers obvious advantages in view of timeliness of results. The 'On-Site Laboratory' (OSL) at the BNFL Sellafield site was the first ever and entered into operation in 1999. For almost five years, the Institute for Transuranium Elements (ITU) has been operating the laboratory under routine conditions. During this period, more than one thousand safeguards samples were analysed. The experience gained in the management, logistics and operation of the OSL allow a critical review based on a significant period in time. This includes also aspects of training of staff, maintenance of equipment, flow of information, and improvements in the efficiency. The analytical issues are of key importance: based on the operational experience, the measurement methods were adapted (changing boundary conditions), the distribution of samples according to material type changed (start up of MOS fabrication plant), and the cutback in resources triggered a further streamlining of the analytical efforts. (orig.)

  18. Customer adoption of small-scale on-site power generation

    International Nuclear Information System (INIS)

    Siddiqui, Afzal S.; Marnay, Chris; Hamachi, Kristina S.; Rubio, F. Javier

    2001-01-01

    The electricity supply system is undergoing major regulatory and technological change with significant implications for the way in which the sector will operate (including its patterns of carbon emissions) and for the policies required to ensure socially and environmentally desirable outcomes. One such change stems from the rapid emergence of viable small-scale (i.e., smaller than 500 kW) generators that are potentially competitive with grid delivered electricity, especially in combined heat and power configurations. Such distributed energy resources (DER) may be grouped together with loads in microgrids. These clusters could operate semi-autonomously from the established power system, or macrogrid, matching power quality and reliability more closely to local end-use requirements. In order to establish a capability for analyzing the effect that microgrids may have on typical commercial customers, such as office buildings, restaurants, shopping malls, and grocery stores, an economic mod el of DER adoption is being developed at Berkeley Lab. This model endeavors to indicate the optimal quantity and type of small on-site generation technologies that customers could employ given their electricity requirements. For various regulatory schemes and general economic conditions, this analysis produces a simple operating schedule for any installed generators. Early results suggest that many commercial customers can benefit economically from on-site generation, even without considering potential combined heat and power and reliability benefits, even though they are unlikely to disconnect from the established power system

  19. Counterterrorism and cybersecurity total information awareness

    CERN Document Server

    Lee, Newton

    2013-01-01

    Provides a broad survey of the United States' counterterrorism history, the use of artificial intelligence in data mining, social media and privacy, cyber attacks and prevention, and longstanding issues of war and peace Closely examines how Total Information Awareness, a governmental data mining project focused on scanning public and private data, plays an integral role in cybersecurity Analyzes recent cyberattacks across the globe orchestrated by 'hacktivist' groups, such as Anonymous

  20. Total fact-book 2000-2005

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    TOTAL S.A., a French society incorporated in France on March 28, 1924, together with its subsidiaries and affiliates, is the fourth largest publicly-traded integrated oil and gas company in the world. This document provides statistical data and information on the corporate (highlights, statements), upstream (production, costs,main producing fields, drilling), upstream maps, downstream (refining, distillation, retail gasoline outlets) and chemicals (sales, specialities). (A.L.B.)

  1. Total fact-book 2000-2005

    International Nuclear Information System (INIS)

    2005-01-01

    TOTAL S.A., a French society incorporated in France on March 28, 1924, together with its subsidiaries and affiliates, is the fourth largest publicly-traded integrated oil and gas company in the world. This document provides statistical data and information on the corporate (highlights, statements), upstream (production, costs,main producing fields, drilling), upstream maps, downstream (refining, distillation, retail gasoline outlets) and chemicals (sales, specialities). (A.L.B.)

  2. Analytical quality control concept in the Euratom on-site laboratories

    International Nuclear Information System (INIS)

    Mayer, K.; Duinslaeger, L.; Cromboom, O.; Ottmar, H.; Wojnowski, D.; Vegt, H. van der

    2001-01-01

    Full text: Two on-site laboratories have been developed, installed, commissioned and put into routine operation by the Euratom safeguards office (ESO), jointly with the Institute for Transuranium Elements (ITU). These laboratories are operated by ITU staff and provide verification measurement results on samples taken by Euratom inspectors. The analysts work in weekly changing shift teams, manage the laboratories and operate the various analytical techniques. Operating such a laboratory at a remote location, without a senior scientist immediately available in case of problems, The existing boundary conditions challenge the robustness of the entire laboratory, i.e. comprising staff and instrumentation. In order to continuously ensure a high degree of reliability of the measurement results, a stringent quality control system was implemented. The quality control concept for the two on-site laboratories was developed at a very early stage and implemented in the pre-OSL training facility at ITU. This enabled to thoroughly test and develop further the concept. At the same time the analysts get acquainted with the quality control procedures in place and they are instilled with the principles. The quality control concept makes use of a fully computerized data management and data acquisition system. All measurement devices, including balances, density meters, mass spectrometers, passive neutron counter, hybrid K-edge instrument, gamma spectrometers and alpha spectrometers are networked and data exchange is performed on electronic basis. A specifically developed laboratory information management system collects individual measurement data, calculates intermediate and final result and shares the information with a quality control module. In order to ensure the reliability of the results, which are reported to the ESO inspectorate, five levels of quality control were implemented. The present paper describes in detail the different levels of quality control, which check the

  3. One-pot strategy for on-site enzyme production, biomass hydrolysis, and ethanol production using the whole solid-state fermentation medium of mixed filamentous fungi.

    Science.gov (United States)

    Maehara, Larissa; Pereira, Sandra C; Silva, Adilson J; Farinas, Cristiane S

    2018-02-01

    The efficient use of renewable lignocellulosic feedstocks to obtain biofuels and other bioproducts is a key requirement for a sustainable biobased economy. This requires novel and effective strategies to reduce the cost contribution of the cellulolytic enzymatic cocktails needed to convert the carbohydrates into simple sugars, in order to make large-scale commercial processes economically competitive. Here, we propose the use of the whole solid-state fermentation (SSF) medium of mixed filamentous fungi as an integrated one-pot strategy for on-site enzyme production, biomass hydrolysis, and ethanol production. Ten different individual and mixed cultivations of commonly used industrial filamentous fungi (Aspergillus niger, Aspergillus oryzae, Trichoderma harzianum, and Trichoderma reesei) were performed under SSF and the whole media (without the extraction step) were used in the hydrolysis of pretreated sugarcane bagasse. The cocultivation of T. reesei with A. oryzae increased the amount of glucose released by around 50%, compared with individual cultivations. The release of glucose and reducing sugars achieved using the whole SSF medium was around 3-fold higher than obtained with the enzyme extract. The addition of soybean protein (0.5% w/w) during the hydrolysis reaction further significantly improved the saccharification performance by blocking the lignin and avoiding unproductive adsorption of enzymes. The results of the alcoholic fermentation validated the overall integrated process, with a volumetric ethanol productivity of 4.77 g/L.h, representing 83.5% of the theoretical yield. These findings demonstrate the feasibility of the proposed one-pot integrated strategy using the whole SSF medium of mixed filamentous fungi for on-site enzymes production, biomass hydrolysis, and ethanol production. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018. © 2018 American Institute of Chemical Engineers.

  4. Recycling of treated domestic effluent from an on-site wastewater treatment system for hydroponics.

    Science.gov (United States)

    Oyama, N; Nair, J; Ho, G E

    2005-01-01

    An alternative method to conserve water and produce crops in arid regions is through hydroponics. Application of treated wastewater for hydroponics will help in stripping off nutrients from wastewater, maximising reuse through reduced evaporation losses, increasing control on quality of water and reducing risk of pathogen contamination. This study focuses on the efficiency of treated wastewater from an on-site aerobic wastewater treatment unit. The experiment aimed to investigate 1) nutrient reduction 2) microbial reduction and 3) growth rate of plants fed on wastewater compared to a commercial hydroponics medium. The study revealed that the chemical and microbial quality of wastewater after hydroponics was safe and satisfactory for irrigation and plant growth rate in wastewater hydroponics was similar to those grown in a commercial medium.

  5. On-site vs off-site management of environmental restoration waste: A cost effectiveness analysis

    International Nuclear Information System (INIS)

    Morse, M.A.; Aamodt, P.L.; Cox, W.B.

    1996-01-01

    The Sandia National Laboratories Environmental Restoration Project is expected to generate relatively large volumes of hazardous waste as a result of cleanup operations. These volumes will exceed the Laboratories existing waste management capacity. This paper presents four options for managing remediation wastes, including three alternatives for on-site waste management utilizing a corrective action management unit (CAMU). Costs are estimated for each of the four options based on current volumetric estimates of hazardous waste. Cost equations are derived for each of the options with the variables being waste volumes, the major unknowns in the analysis. These equations provide a means to update cost estimates as volume estimates change. This approach may be helpful to others facing similar waste management decisions

  6. On-site habitability in the event of an accident at a nuclear facility

    International Nuclear Information System (INIS)

    1989-01-01

    This publication is intended to provide technical guidance and a methodology for regulatory bodies, designers, constructors and operators of nuclear facilities to assist them in assessing the current situation as regards on-site habitability for their specific nuclear facilities. Initially, the aim will be to ensure that the ''vital areas'' of the facility which are necessary for the safe operation and shutdown of the facility will remain habitable, in some cases continuously and in others transiently, in the event of an accident inside or outside the installation. The assessment procedure can be used not only for potential radiation accidents but also to consider the effects on habitability of those probable non-radiological events which, if not correctly and effectively countered, could lead to the development of potentially unsafe conditions in the facility itself. 30 refs, 4 figs, 8 tabs

  7. Facilities and medical care for on-site nuclear power plant radiological emergencies

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    The operation of a nuclear power plant introduces risks of injury or accidents that could also result in the exposure of personnel to radiation or radioactive materials. It is important in such an event to have adequate first aid and medical facilities, supplies, equipment, transportation capabilities and trained personnel available to provide necessary care. This standard provides guidance for first aid during an emergency and for initial medical care of those overexposed to penetrating radiation or contaminated with radioactive material or radionuclides. Recommendations cover facilities, supplies, equipment and the extent of care on-site, where first aid and initial care may be provided, and off-site at a local hospital, where further medical and surgical care may be provided. Additional recommendations are also provided for the transportation of patients and the training of personnel. A brief discussion of specialized care is provided in an appendix

  8. A method for the rapid on-site assessment of handleability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, D.W.; Atkin, B.P. [University of Nottingham, Nottingham (United Kingdom). School of Chemical, Environmental and Mining Engineering

    2000-07-01

    The handleability monitor has been specifically designed to provide a simple, rapid and on-site assessment of the whole or part consignment of a coal blend in its 'as-prepared' or 'as-received' condition. Evaluation has been carried out at a number of user's coal-handling plants, on both metallurgical and power station coals from a variety of sources world-wide (Australia, South Africa, United Kingdom and USA). The results are used to predict which coals could routinely pass through handling plant at line capacity, without causing blockage or decay, and have also been correlated with the operator's perception of the coal's handling characteristics and problems caused (blockages in chutes, hoppers, etc.) on the coal handling plant. Monitors were located at a coal fired power station and at a coal handling plant at an iron and steel works. 16 refs., 9 figs.

  9. Development of a portable test device for assessing on-site floor slipperiness: an interim report.

    Science.gov (United States)

    Grönqvist, R; Hirvonen, M; Rajamäki, E

    2001-04-01

    The main objective was to design and construct a prototype portable slipmeter with the capability of measuring static, transitional kinetic and steady-state kinetic coefficient of friction properties of on-site floors. The second objective was to evaluate its operation in the laboratory, using a commercial force platform as reference. The prototype was found to be capable of measuring the described frictional characteristics of floor surfaces, using three different test wheels and two modes of operation, impact and non-impact testing. The results anticipate that the slipmeter may prove to be more valid than any traditional measurement technique. The study continues with biomechanical trials and will be completed during the year 2000.

  10. Heat-flow properties of systems with alternate masses or alternate on-site potentials

    Science.gov (United States)

    Pereira, Emmanuel; Santana, Leonardo M.; Ávila, Ricardo

    2011-07-01

    We address a central issue of phononics: the search of properties or mechanisms to manage the heat flow in reliable materials. We analytically study standard and simple systems modeling the heat flow in solids, namely, the harmonic, self-consistent harmonic and also anharmonic chains of oscillators, and we show an interesting insulating effect: While in the homogeneous models the heat flow decays as the inverse of the particle mass, in the chain with alternate masses it decays as the inverse of the square of the mass difference, that is, it decays essentially as the mass ratio (between the smaller and the larger one) for a large mass difference. A similar effect holds if we alternate on-site potentials instead of particle masses. The existence of such behavior in these different systems, including anharmonic models, indicates that it is a ubiquitous phenomenon with applications in the heat flow control.

  11. On-site treatment and landfilling of MSWI air pollution control residues

    DEFF Research Database (Denmark)

    Lundtorp, Kasper; Jensen, Dorthe Lærke; Sørensen, Mette Abildgaard

    2003-01-01

    the process, collected through the drainage system, contained large concentrations of salts (Cl: 14–30 g/l, Na: 4–9 g/l, K: 5–11 g/l, Ca: 2–12 g/l) but low concentrations of trace metals (e.g. Pb: 14–100 μg/l, Cd: leaching......Air pollution control (APC) residues from municipal solid waste incineration (MSWI) are difficult to landfill due to substantial leaching of trace metals. An on-site pretreatment prior to landfilling of APC-residues was investigated in terms of bench-scale experiments with a semidry APC...... of the leaching, concentrations of trace metals were reduced by up to four orders of magnitude....

  12. Enhancing nuclear power plant safety via on-site mental fatigue management

    Directory of Open Access Journals (Sweden)

    Tsai Ming-Kuan

    2017-01-01

    Full Text Available Nuclear incidents and accidents have occurred at various nuclear power plants. Since some of these incidents and accidents caused by human errors might be preventable, numerous researchers argue that fatigue management for on-site workers is the key, especially for mental fatigue. Thus, this study proposes an approach consisting of two mechanisms. A fatigue monitor could identify the mentally fatigued workers by detecting their brain wave rhythms through a brain-computer interface. For such workers, a fatigue alert would awaken them. If the status of the mentally fatigued workers becomes worse, based on a positioning technique (i.e., wireless networks, this mechanism would alert the nearby workers and managers to deal with this condition. The test results indicate that the proposed approach enhanced the capacity to examine the mentally fatigued workers, ensured the accuracy in locating these workers, and avoided possible nuclear incidents. This study is a useful reference for similar applications in the nuclear industry.

  13. A Review of On-Site Wastewater Treatment Systems in Western Australia from 1997 to 2011

    Science.gov (United States)

    Gunady, Maria; Shishkina, Natalia; Tan, Henry; Rodriguez, Clemencia

    2015-01-01

    On-site wastewater treatment systems (OWTS) are widely used in Western Australia (WA) to treat and dispose of household wastewater in areas where centralized sewerage systems are unavailable. Septic tanks, aerobic treatment units (ATUs), and composting toilets with greywater systems are among the most well established and commonly used OWTS. However, there are concerns that some OWTS installed in WA are either performing below expected standards or failing. Poorly performing OWTS are often attributed to inadequate installation, inadequate maintenance, poor public awareness, insufficient local authority resources, ongoing wastewater management issues, or inadequate adoption of standards, procedures, and guidelines. This paper is to review the installations and failures of OWTS in WA. Recommendations to the Department of Health Western Australia (DOHWA) and Local Government (LG) in regard to management strategies and institutional arrangements of OWTS are also highlighted. PMID:25960745

  14. Evaluation of reliability of on-site A.C. power systems based on maintenance records

    International Nuclear Information System (INIS)

    Basso, G.; Pia, S.; Fusari, W.; Soressi, G.; Vaccari, G.

    1986-01-01

    To the end of ascertain in what extent the evaluation of reliability of emergency diesel generators (D.G.) can be improved by means of a deeper knowledge of their operating history a study has been carried-out on 21 D.G. sets: 4 D.G. of the Caorso nuclear plant (BWR, 870 MWe) and 17 D.G. in service at 6 steam-electric fossil-fuelled plants. The major points of interest resulting from this study are: 1) reliability assessments of A.C. on-site power Systems, made on the basis of outcomes of surveillance tests, may lead to results which overestimate the real performance. 2) the unreliability of a redundant System of stand-by components is determined in large extent by unavailabilities due to scheduled and unscheduled maintenance, latent failures, tests. (authors)

  15. Operating experience and licensing criteria relating to on-site electric power systems in Italy

    Energy Technology Data Exchange (ETDEWEB)

    Ciattaglia, S.; Grimaldi, G. [ENEA/DISP, Via Vitaliano Brancati, 48, 00144 Roma/Rome (Italy)

    1986-02-15

    The most significant events of on-site electrical power supply degradation in Italian plants took place in coincidence with severe atmospheric conditions or with the propagation of disturbances by lightning stroke inside the plant. Essential instrumentation was lost in two cases so that, for some time, no indication of the plant status was allowed. In both cases the recovery of the plant was achieved by restoration of external power supply. Corrective actions included both improvement in immunity to disturbances, redundancy, capability and physical separation and DG's reliability demonstration. Design and safety analysis of new plants are now carried out with the help of reliability studies and probabilistic risk assessment. As a result, design changes were performed on new plants to improve the reliability of DGs start-up and the independence of the electrical emergency divisions. (authors)

  16. Evaluation of reliability of on-site A.C. power systems based on maintenance records

    Energy Technology Data Exchange (ETDEWEB)

    Basso, G.; Pia, S. [ENEA/TERM/VAOEC, C.R.E. Casaccla via Anguillarese, 00100 Roma/Rome (Italy); Fusari, W. [ENEL, Rome (Italy); Soressi, G.; Vaccari, G. [ENEL, Centro di Ricerca Termica e Nucl., Via Rubattino, 54, 1-20134 Mllano/Milan (Italy)

    1986-02-15

    To the end of ascertain in what extent the evaluation of reliability of emergency diesel generators (D.G.) can be improved by means of a deeper knowledge of their operating history a study has been carried-out on 21 D.G. sets: 4 D.G. of the Caorso nuclear plant (BWR, 870 MWe) and 17 D.G. in service at 6 steam-electric fossil-fuelled plants. The major points of interest resulting from this study are: 1) reliability assessments of A.C. on-site power Systems, made on the basis of outcomes of surveillance tests, may lead to results which overestimate the real performance. 2) the unreliability of a redundant System of stand-by components is determined in large extent by unavailabilities due to scheduled and unscheduled maintenance, latent failures, tests. (authors)

  17. Modeling injury rates as a function of industrialized versus on-site construction techniques.

    Science.gov (United States)

    Rubio-Romero, J C; Suárez-Cebador, M; Abad, Jesús

    2014-05-01

    It is often predicted that the industrialization of building activities will lead to a reduction of accident rates in the construction sector, particularly as a result of switching activities from building sites to factories. However, to date no scientific research has provided objective quantitative results to back up this claim. The aim of this paper is to evaluate how industrialization affects the accident rate in different industrialized building systems in Spain. Our results revealed that the industrialized steel modular system presents the lowest accident rate, while the highest accident rate was recorded in the construction method with cast-in-place concrete. The lightweight construction system also presents a high accident rate. Accordingly, industrialized building systems cannot claim to be safer than traditional ones. The different types of "on-site work" seem to be the main variable which would explain the accident rates recorded in industrialized construction systems. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. NRC perspective on extended on-site storage of low-level radioactive waste after 1993

    International Nuclear Information System (INIS)

    Remick, Forrest J.

    1992-01-01

    The Low-Level Radioactive Waste Policy Amendments Act of 1985 (LLRWPAA) requires that each State, which has not provided for disposal capacity by January 1, 1993, must take title and possession of the low-level radioactive wastes generated in the State. If the states do not take title and possession of the wastes, the rebates to which the states would have been entitled to would be returned to the waste generators. in considering the matter, the Commission solicited comments from States) low-level radioactive waste compacts, local governments, and the general public so that the public's views could be factored into the Commission's deliberations on this issue. This paper addresses the current status of NRC positions on the adequacy of the NRC's existing regulatory framework associated with the title transfer provisions of the LLRWPAA and the Commission's views on extended on-site storage of low-level radioactive wastes after the 1993 and 1996 milestones. (author)

  19. Experiences in solving the challenges of on-site degree programs

    International Nuclear Information System (INIS)

    Christenson, J.M.; Eckart, L.E.

    1987-01-01

    The University of Cincinnati (UC) Nuclear Engineering Program Faculty has now had six years of experience in delivering on-site educational programs to nuclear power plant technical personnel. Programs of this type present a variety of challenges to the faculty, the management of the client utility and to the students who become involved in a particular program. This paper describes how each of these groups can identify and successfully solve these challenges. The solutions the authors describe are drawn from their own experiences which have been described in some detail elsewhere. Other solutions to those challenges are certainly possible. They make no claim for the particular ones they offer, beyond the fact that they have worked over a sustained period of time and that results they have produced have left all three parties mutually satisfied

  20. Operating experience and licensing criteria relating to on-site electric power systems in Italy

    International Nuclear Information System (INIS)

    Ciattaglia, S.; Grimaldi, G.

    1986-01-01

    The most significant events of on-site electrical power supply degradation in Italian plants took place in coincidence with severe atmospheric conditions or with the propagation of disturbances by lightning stroke inside the plant. Essential instrumentation was lost in two cases so that, for some time, no indication of the plant status was allowed. In both cases the recovery of the plant was achieved by restoration of external power supply. Corrective actions included both improvement in immunity to disturbances, redundancy, capability and physical separation and DG's reliability demonstration. Design and safety analysis of new plants are now carried out with the help of reliability studies and probabilistic risk assessment. As a result, design changes were performed on new plants to improve the reliability of DGs start-up and the independence of the electrical emergency divisions. (authors)

  1. On-site comprehensive analysis of explosives using HPLC-UV-PAED

    Science.gov (United States)

    Marple, Ronita L.; LaCourse, William R.

    2004-03-01

    High-performance liquid chromatography with ultra violet and photo-assisted electrochemical detection (HPLC-UV-PAED) has been developed for the sensitive and selective detection of explosives in ground water and soil extracts. Fractionation and preconcentration of explosives is accomplished with on-line solid phase extraction (SPE), which minimizes sample pretreatment and enables faster and more accurate on-site assessment of a contaminated site. Detection limits are equivalent or superior (i.e., applicable, as it is capable of determining a wider range of organic nitro compounds. Soil samples are extracted using pressurized fluid extraction (PFE), and this technique is automatable, field-compatible, and environmentally friendly, adding to the overall efficiency of the methodology.

  2. Evaluation of gamma-spectrometry equipment for on-site inspection

    International Nuclear Information System (INIS)

    Burnett, J.L.; Milbrath, B.D.; Mueller, W.F.

    2017-01-01

    An On-site Inspection (OSI) is an important component of the verification regime of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), with the objective of gathering evidence of a possible Treaty violation. This includes the use of gamma-spectrometry equipment to identify 17 particulate radionuclides that are indicative of a nuclear explosion. This research provides an evaluation of high- (germanium), medium- (cadmium zinc telluride) and low-resolution (sodium iodide and lanthanum bromide) detectors using modelled radionuclide signatures from a nuclear explosion and Monte Carlo simulations of a detector response. The complex radionuclide signatures are shown to only be distinguishable using a high-resolution system for 1 week and 1 year post-detonation cases. (author)

  3. On-site inspection for the radionuclide observables of an underground nuclear explosion

    International Nuclear Information System (INIS)

    Burnett, J.L.

    2015-01-01

    Under the Comprehensive Nuclear-Test-Ban Treaty an on-site inspection (OSI) may be undertaken to identify signatures from a potential nuclear explosion. This includes the measurement of 17 particulate radionuclides ( 95 Zr, 95 Nb, 99 Mo, 99m Tc, 103 Ru, 106 Rh, 132 Te, 131 I, 132 I, 134 Cs, 137 Cs, 140 Ba, 140 La, 141 Ce, 144 Ce, 144 Pr, 147 Nd). This research provides an assessment of the potential to detect these radionuclides during an OSI within 1 week to 2 years after a nuclear explosion at two locations. A model has been developed that simulates the underground detonation of a 1 kT 235 U nuclear weapon with 1 % venting. This indicates a requirement to minimise the time since detonation with accurate determination of the test location. (author)

  4. User's manual for applicants proposing on-site burial of self-generated radioactive waste

    International Nuclear Information System (INIS)

    Tolbert, M.E.M.; Loretan, P.A.

    1987-01-01

    This document describes, for medical and research institutions as well as industrial generators of low-level radioactive waste, the NRC or state submittal requirements for authorizing the on-site burial of self-generated radioactive waste. An important part of completing the license application for operation justifying this alternative for waste disposal over other alternatives. Reasons that might be considered acceptable might include the need to dispose of large volumes of low activity waste that would otherwise take up valuable space in commercial sites; the ability to demonstrate that this method of disposal will result in reduced exposures to the public; the ability to show that the prohibitive costs of other methods of disposal would be detrimental to the progress of significant research which generates radioactive waste. 19 refs., 3 figs., 4 tabs

  5. On-Site Measurements for Voltage Unbalance Studies Associated with the AC Railway Operation

    DEFF Research Database (Denmark)

    Stamatopoulos, Athanasios; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    unbalance with regards to traction loads has been augmented since the decision to expand the electric railway. Towards this direction, and on the occasion of a newly built electrified line, voltage unbalance measurements were carried out and are presented in this paper. The information from the extracted......On-site measurements in Electrical Power Systems can provide valuable information about the performance of the network and also, can be of great assistance to the validation and assessment of simulation models developed for power system studies. Lately, the noticeable increase of non......-conventional types of loads, such as the AC railway, has raised concerns regarding the secure operation of power transmission networks. This renders the monitoring and reporting of various aspects of system’s power quality even more necessary. For the Danish transmission grid, in particular, the relevance of voltage...

  6. Corrosion rate of steel in concrete - Evaluation of confinement techniques for on-site corrosion rate

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica; Elsener, Bernhard

    2009-01-01

    Earlier on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when different commercially available instruments are used. The different confinement techniques, rather than the different electrochemical techniques used in the instruments, are considered...... to be the main reason for the discrepancies. This paper presents a method for the quantitative assessment of confinement techniques based on monitoring the operation of the corrosion rate instrument and the current distribution between the electrode assembly on the concrete surface and a segmented reinforcement...... bar embedded in the concrete. The applicability of the method was demonstrated on two commercially available corrosion rate instruments based on different confinement techniques. The method provided an explanation of the differences in performance of the two instruments. Correlated measurements...

  7. Topological phases in the Haldane model with spin–spin on-site interactions

    Science.gov (United States)

    Rubio-García, A.; García-Ripoll, J. J.

    2018-04-01

    Ultracold atom experiments allow the study of topological insulators, such as the non-interacting Haldane model. In this work we study a generalization of the Haldane model with spin–spin on-site interactions that can be implemented on such experiments. We focus on measuring the winding number, a topological invariant, of the ground state, which we compute using a mean-field calculation that effectively captures long-range correlations and a matrix product state computation in a lattice with 64 sites. Our main result is that we show how the topological phases present in the non-interacting model survive until the interactions are comparable to the kinetic energy. We also demonstrate the accuracy of our mean-field approach in efficiently capturing long-range correlations. Based on state-of-the-art ultracold atom experiments, we propose an implementation of our model that can give information about the topological phases.

  8. Validation of on-site job-built guardrails with shoring jack as supports

    Directory of Open Access Journals (Sweden)

    Lan, A.

    2014-06-01

    Full Text Available To protect themselves against fall hazards in a slab-column frame, workers use the row of shoring jacks installed at 1 m from the edge as supports for on-site built guardrails. Inspectors of the Quebec Workers Compensation Board (Commission de la santé et de la sécurité du travail (CSST have expressed concern about the safety and compliance of these on-site built guardrails with the Quebec Safety Code for the Construction Industry (S-2.1, r.4. Some workers have also inquired if the shoring jack can be used as an anchor for a travel restraint system. The present study describes how an evaluation method and a test protocol have been used to verify if guardrails built on-site, with shoring jacks as supports, are safe and comply with the requirements of S-2.1, r.4 and if the shoring jack can be used as an anchor point for a travel restraint system. The results of the study show 1 guardrails built on site with shoring jacks as supports, are safe and comply with S-2.1, r.4 and 2 shoring jacks used as supports for guardrails must not be used as an anchor for a travel restraint system.Para la protección contra el peligro de caída en altura durante la ejecución de la estructura de un edificio, los trabajadores utilizan puntales acodalados a dos forjados y situados a 1 metro del borde de forjado como apoyo de las barandillas de seguridad. Inspectores de la Quebec Workers Compensation Board (Commision de la santé et de la sécurité du travail (CSST han expresado su preocupación por la seguridad y el cumplimiento de estos sistemas de protección en la construcción conforme al Código de Seguridad de Quebec para la industria de la construcción (S-2.1, R.6. Así mismo algunos trabajadores han mostrado su inquietud sobre la utilización de los puntales como sistemas para limitar el desplazamiento. El presente estudio describe un método de evaluación y un procedimiento de ensayo que se han utilizado para verificar si las barandillas de seguridad

  9. The protection of on-site personnel in the event of a radiological accident

    International Nuclear Information System (INIS)

    Morrey, M.; Simister, D.N.

    2003-01-01

    The National Radiological Protection Board (NPRB) is responsible in the UK for advising Government and other responsible bodies on the principles for responding to radiological emergencies. NRPB has published appropriate advice on the off-site protection of the public and on the protection of workers involved in taking mitigating actions to reduce the exposure of others. This paper puts forward a suggested framework for the protection of on-site personnel in the event of a radiological emergency which might include a criticality accident. This framework both dovetails with existing planning for the protection of members of the public off-site, and also takes account of specific differences between the situations on and off-site. (author)

  10. Revaluation of breast cytology with pathologist on-site of lesions with suspicious sonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Capalbo, Emanuela, E-mail: emanuelacapalbo@tiscalinet.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Sajadidehkordi, Farideh, E-mail: faridehit@yahoo.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Colombi, Claudio; Ticha, Vladimira; Moretti, Angela, E-mail: info.radiologia@sancarlo.mi.it [Dipartimento di Scienze Diagnostiche, UOC di Radiologia Diagnostica ed Interventistica, A.O San Carlo Borromeo. Via Pio II, 3, 20153 Milano (Italy); Peli, Michela, E-mail: peli.michela@gmail.com [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Cosentino, Maria, E-mail: maria-cosentino@tiscali.it [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Lovisatti, Maria, E-mail: marialovisatti@hotmail.com [Scuola di Specializzazione di Radiologia Diagnostica ed Interventistica, Università degli Studi di Milano Via Di Rudinì, Milano, 20142 Italy (Italy); Berti, Elisabetta, E-mail: eliberti@hotmail.it [Dipartimento di Scienze Diagnostiche, UOC di Anatomia Patologica, A.O San Carlo Borromeo. Via Pio II, 3, Milano 20153 (Italy); Cariati, Maurizio, E-mail: info.radiologia@sancarlo.mi.it [Dipartimento di Scienze Diagnostiche, UOC di Radiologia Diagnostica ed Interventistica, A.O San Carlo Borromeo. Via Pio II, 3, 20153 Milano (Italy)

    2013-09-15

    Objective: Evaluating correlation estimation between diagnostic ultrasound (U.S.) of breast lesions and fine needle aspiration cytology (FNAC), and the correlation between cytology and histology (I) of these lesions undergo surgery. Materials and methods: In 2010 we performed 1589 ultrasound breast. We identified 210 suspicious lesions to be subjected to FNAC, which was performed with pathologist on site, and extemporaneous analysis of the sample to assess their appropriateness. We classified the lesions in 5 ultrasound (U) classes according to the criteria defined by Echographic BIRADS Lexicon. The results of cytology were classified in 5 classes (C) according to the guidelines of F.O.N.Ca.M. Then we evaluated the diagnostic correlation between U.S. and FNAC, and between FNAC and Histology. Results: The distribution of lesions in U classes was: 57U2, 55U3, 36U4 and 62U5. The diagnostic concordance between U and FNAC was 96.7%, with a sensitivity of 98%, specificity 93%, negative and positive predictive value respectively of 94.9% and 97.3%, and diagnostic accuracy of 96.6%. The 98 patients with C4-C5 lesions were subjected to surgery and the histology confirmed high-grade malignancy of lesions with a concordance of 99.7%. Conclusions: Having achieved high diagnostic concordance between U and FNAC, and then between FNAC and histology, we may say that the FNAC, less invasive and traumatic for the patient than needle biopsy (CB), may be still a valid method when performed with pathologist on-site to assess the adequacy of the sample taken.

  11. Recreational use in dispersed public lands measured using social media data and on-site counts.

    Science.gov (United States)

    Fisher, David M; Wood, Spencer A; White, Eric M; Blahna, Dale J; Lange, Sarah; Weinberg, Alex; Tomco, Michael; Lia, Emilia

    2018-09-15

    Outdoor recreation is one of many important benefits provided by public lands. Data on recreational use are critical for informing management of recreation resources, however, managers often lack actionable information on visitor use for large protected areas that lack controlled access points. The purpose of this study is to explore the potential for social media data (e.g., geotagged images shared on Flickr and trip reports shared on a hiking forum) to provide land managers with useful measures of recreational use to dispersed areas, and to provide lessons learned from comparing several more traditional counting methods. First, we measure daily and monthly visitation rates to individual trails within the Mount Baker-Snoqualmie National Forest (MBSNF) in western Washington. At 15 trailheads, we compare counts of hikers from infrared sensors, timelapse cameras, and manual on-site counts, to counts based on the number of shared geotagged images and trip reports from those locations. Second, we measure visitation rates to each National Forest System (NFS) unit across the US and compare annual measurements derived from the number of geotagged images to estimates from the US Forest Service National Visitor Use Monitoring Program. At both the NFS unit and the individual-trail scales, we found strong correlations between traditional measures of recreational use and measures based on user-generated content shared on the internet. For national forests in every region of the country, correlations between official Forest Service statistics and geotagged images ranged between 55% and 95%. For individual trails within the MBSNF, monthly visitor counts from on-site measurements were strongly correlated with counts from geotagged images (79%) and trip reports (91%). The convenient, cost-efficient and timely nature of collecting and analyzing user-generated data could allow land managers to monitor use over different seasons of the year and at sites and scales never previously

  12. On-site preparation of technetium-99m labeled human serum albumin for clinical application

    International Nuclear Information System (INIS)

    Wang Yuhfeng; Chuang Meihua; Cham Thauming; Chung Meiing; Chiu Jainnshiun

    2007-01-01

    Technetium-99m labeled human serum albumin (Tc-99m HSA) is an important radiopharmaceutical for clinical applications, such as cardiac function tests or protein-losing gastroenteropathy assessment. However, because of transfusion-induced infectious diseases, the safety of serum products is a serious concern. In this context, serum products acquired from patients themselves are the most ideal tracer. However, the development of rapid separation and easy clinical labeling methods is not yet well established. Under such situation, products from the same ethnic group or country are now recommended by the World Health Organization as an alternative preparation. This article describes the on-site preparation of Tc-99m HSA from locally supplied serum products. Different formulations were prepared and the labeling efficiency and stability were examined. Radio-labeling efficiencies were more than 90% in all preparation protocols, except for one that omitted the stannous solution. The most cost-effective protocol contained HSA 0.1 mg, treated with stannous fluoride 0.2 mg, and mixed with Tc-99m pertechnetate 30 mCi. A biodistribution study was performed in rats using a gamma camera immediately after intravenous administration of radiolabeled HSA. Tissue/organ uptake was obtained by measuring the radioactivity in organs after sacrificing the rats at timed intervals. The biologic half-life was about 32 min, determined from sequential venous blood collections. These data indicate that our preparation of Tc-99m HSA is useful and potentially applicable clinically. In addition, this on-site preparation provides the possibility of labeling a patient's own serum for subsequent clinical application. (author)

  13. An overview of the on-site inspection measurements from the non-proliferation experiment

    Energy Technology Data Exchange (ETDEWEB)

    Zucca, J.J. [Lawrence Livermore National Lab., CA (United States)

    1994-12-31

    An on-site inspection (OSI) is an in-person visit to site to collect data and examine evidence in order to determine the source of an ambiguous event detected via remote monitoring systems or other measures. Its purpose is to determine whether the treaty has been violated, to deter violations, and to build confidence. At the time of this writing, it is anticipated that the Comprehensive Test Ban Treaty (CTBT) being developed in the Conference on Disarmament will contain OSI provisions. In an era of testing moratoria, the Non-Proliferation Experiment (NPE) provided a unique opportunity to investigate candidate OSI techniques. On site inspections could occur in three different contexts: after-the-fact inspections based on information from remote monitoring systems; inspections prior to, during, and after large declared chemical explosions (e.g., a large mining explosion); continuous monitoring inspections with unattended sensors at certain agreed-upon sites (e.g., previous test sites). OSI monitoring techniques need to be designed to detect the phenomena and residual effects of nuclear explosions. In the underground case, the primary effects of interest for OSI are the electromagnetic pulse, shock waves, aftershocks, radioactive gas, rubble zone, and apical void. These effects are well known and the basic techniques for their detection well established. We designed our measurement program for the NPE to answer specific issues about these detection technologies. Our measurement program includes the following: zerotime electromagnetic measurements; seismic aftershock survey; before and after electrical soundings; gas tracers introduced into the explosive; before and after multispectral overhead imagery from low-flying aircraft; before and after geological surveys.

  14. Dynamic analysis of the PEC fast reactor vessel: On-site tests and mathematical models

    International Nuclear Information System (INIS)

    Zola, M.; Martelli, A.; Masoni, P.; Scandola, G.

    1988-01-01

    This paper presents the main features and results of the on-site dynamic tests and the related numerical analyses carried out for the PEC reactor vessel. The purpose is to provide an example of on-site testing of large components, stressing the problems encountered during the experiments, as well as in the processing phase of the test results and for the comparisons between calculations and measurements. Tests, performed by ISMES on behalf of ENEA, allowed the dynamic response of the empty vessel to be measured, thus providing data for the verification of the numerical models of the vessel supporting structure adopted in the PEC reactor-block seismic analysis. An axisymmetric model of the vessel, implemented in the NOVAX code, had been developed in the framework of the detailed numerical studies performed by NOVATOME (again on behalf of ENEA), to check the beam schematization with fluid added mass model adopted by ANSALDO in SAP-IV and ANSYS for the reactor-block design calculations. Furthermore, a numerical model, describing vessel supporting structure in detail, was also developed by ANSALDO and implemented in the SAP-IV code. The test conditions were analysed by use of these and the design models. Comparisons between calculations and measurements showed particularly good agreement with regard to first natural frequency of the vessel and rocking stiffness of the vessel supporting structure, i.e. those parameters on which vessel seismic amplification mainly depends: this demonstrated the adequacy of the design analysis to correctly calculate the seismic motion at the PEC core diagrid. (author). 5 refs, 23 figs, 4 tabs

  15. Dynamic analysis of the PEC fast reactor vessel: on-site tests and mathematical models

    International Nuclear Information System (INIS)

    Zola, Maurizio; Martelli, Alessandro; Maresca, Giuseppe; Masoni, Paolo; Scandola, Giani; Descleves, Pierre

    1988-01-01

    This paper presents the main features and results of the on-site dynamic tests and the related numerical analysis carried out for the PEC reactor vessel. The purpose is to provide an example of on-site testing of large components, stressing the problems encountered during the experiments, as well as in the processing phase of the test results and for the comparisons between calculations and measurements. Tests, performed by ISMES on behalf of ENEA, allowed the dynamic response of the empty vessel to be measured, thus providing data for the verification of the numerical models of the vessel supporting structure adopted in the PEC reactor-block seismic analysis. An axisymmetric model of the vessel, implemented in the vessel, implemented in the NOVAK code, had been developed in the framework of the detailed numerical studies performed by NOVATOME (again on behalf of ENEA), to check the beam schematization with fluid added mass model adopted by ANSALDO in SAP-IV and ANSYS for the reactor-block design calculations. Furthermore, a numerical model, describing vessel supporting structure in detail, was also developed by ANSALDO and implemented in the SAP-IV code. The test conditions were analysed by use of these and the design models. Comparisons between calculations and measurements showed particularly good agreement with regard to first natural frequency of the vessel and rocking stiffness of the vessel supporting structure, i.e. those parameters on which vessel seismic amplification mainly depends: this demonstrated the adequacy of the design analysis to correctly calculate the seismic motion at the PEC core diagrid. (author)

  16. Water-chemistry and on-site sulfur-speciation data for selected springs in Yellowstone National Park, Wyoming, 1994-1995

    Science.gov (United States)

    Ball, James W.; Nordstrom, D. Kirk; Cunningham, Kirk M.; Schoonen, Martin A.; Xu, Yong; DeMonge, Jennifer M.

    1998-01-01

    Forty-two water analyses are reported for samples collected at 8 hot springs and their overflow drainages, two geysers, and two ambient-temperature acid streams in Yellowstone National Park during 1994-95. These water samples were collected and analyzed as part of the initial research investigations on sulfur redox speciation in the hot springs of Yellowstone and to document chemical changes in overflows that affect major ions, redox species, and trace elements. The sulfur redox speciation research is a collaboration between the State University of New York (SUNY) at Stony Brook and the U.S. Geological Survey (USGS). Four hot springs, Ojo Caliente, Azure, Frying Pan, and Angel Terrace, were studied in detail. Analyses were performed adjacent to the sampling site or in an on-site mobile lab truck constructed by the USGS, or later in a USGS laboratory. Water temperature, specific conductance, pH, Eh, D.O., and dissolved H2S were determined adjacent to the sample source at the time of sampling. Alkalinity and F- were determined on-site on the day of sample collection. Thiosulfate and polythionates were determined as soon as possible (minutes to hours later) by ion chromatography (IC). Other major anions (Cl-, SO4 2-, Br-) also were determined on-site by IC within two days of sample collection. Ammonium, Fe(II), and Fe(total) were determined on-site by ultraviolet/visible spectrophotometry within two days of sample collection. Later in the USGS laboratory, densities were determined. Concentrations of Ca, Mg, Li, Na, and K were determined by flame atomic absorption and emission (Na, K) spectrometry. Concentrations of Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe(total), K, Mg, Mn, Na, Ni, Pb, Si, Sr, V, and Zn were determined by inductively-coupled plasma optical emission spectrometry. Trace concentrations of Al and Mg were determined by Zeeman-corrected graphite furnace atomic absorption spectrometry. Three important conclusions from the sampling and analyses are: (1

  17. 28 CFR Appendix C to Part 79 - Radiation Exposure Compensation Act Offset Worksheet-On Site Participants

    Science.gov (United States)

    2010-07-01

    ..., Column 4 “Actuarial Present Value”of past payments = $0.00 NET AMOUNT OWED CLAIMANT ($75,000 less APV... Compensation Act Offset Worksheet—On Site Participants [Present CPI = 185.20] VA paymentsyear Payment Indicated...

  18. 77 FR 14832 - Plumchoice, Inc., Including On-Site Leased Workers From Balance Staffing, Insight Global Staffing...

    Science.gov (United States)

    2012-03-13

    ...., Including On-Site Leased Workers From Balance Staffing, Insight Global Staffing, and Technisource..., Insight Global Staffing, and Technisource, Scarborough, Maine. The workers are engaged in activities... leased workers from Balance Staffing, Insight Global Staffing, and Technisource, Scarborough, Maine, who...

  19. evaluation of total annual costs of heat exchanger networks using

    African Journals Online (AJOL)

    user

    after solving the first problem using RPA based heat integration gave a minimum total annual cost (TAC) of $237, ... mathematical programming and non-RPA based Hint software. ... The concept of pinch analysis evolved over the years.

  20. Superconducting correlations in the one-band Hubbard model with intermediate on-site and weak attractive intersite interactions

    International Nuclear Information System (INIS)

    Jain, K.P.; Ramakumar, R.; Chancey, C.C.

    1990-01-01

    In this paper, we analyze a simple extended Hubbard model with an intermediate on-site interaction (both repulsive and attractive) and a weak intersite attractive interaction. Following Hubbard decoupling approximations and introducing Hubbard subband operators, we obtain a generalized gap function for singlet s-wave pairing that explicitly depends on the Hubbard subband energies. For the on-site repulsive-interaction case, we find that the superconductivity is not destroyed in the intermediate-interaction regime, contrary to the prediction of a Hartree-Fock mean-field treatment. The essential consequence of the on-site repulsion is the formation of the Hubbard subbands separated by the Mott-Hubbard gap, and it is within these subbands that pairing induced by the intersite interaction occurs. For the attractive on-site interaction case, the on-site pairing amplitude is found to be proportional to the bandwidth, and the gap function has contributions from both on-site and intersite pairing. The relevance of the model to high-temperature superconductivity is discussed