WorldWideScience

Sample records for on-line sample processing

  1. On-line sample processing methods in flow analysis

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2008-01-01

    In this chapter, the state of the art of flow injection and related approaches thereof for automation and miniaturization of sample processing regardless of the aggregate state of the sample medium is overviewed. The potential of the various generation of flow injection for implementation of in......-line dilution, derivatization, separation and preconcentration methods encompassing solid reactors, solvent extraction, sorbent extraction, precipitation/coprecipitation, hydride/vapor generation and digestion/leaching protocols as hyphenated to a plethora of detection devices is discussed in detail...

  2. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K. [Oulu Univ. (Finland)

    1998-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  3. On-line sample processing involving microextraction techniques as a front-end to atomic spectrometric detection for trace metal assays: A review

    Energy Technology Data Exchange (ETDEWEB)

    Miró, Manuel, E-mail: manuel.miro@uib.es [FI-TRACE Group, Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, E-07122 Palma de Mallorca, Illes Balears (Spain); Hansen, Elo Harald [Granåsen 93, DK-2800 Kgs. Lyngby (Denmark)

    2013-06-11

    Graphical abstract: -- Highlights: •Role of flow injection in automation of microextraction techniques for metal assays. •On-line coupling of liquid phase microextraction (LPME) to atomic spectrometry. •Critical evaluation of on-line single drop and dispersive LPME. •On-line coupling of micro-solid phase extraction (μSPE) to atomic spectrometry. •Critical appraisal of magnetic/carbon nanoparticles and biomass for on-line μSPE. -- Abstract: Within the last decade, liquid-phase microextraction (LPME) and micro-solid phase extraction (μSPE) approaches have emerged as substitutes for conventional sample processing procedures for trace metal assays within the framework of green chemistry. This review surveys the progress of the state of the art in simplification and automation of microextraction approaches by harnessing to the various generations of flow injection (FI) as a front end to atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS) or inductively coupled plasma atomic emission spectrometry or mass spectrometry (ICP-AES/MS). It highlights the evolution of flow injection analysis and related techniques as vehicles for appropriate sample presentation to the detector and expedient on-line matrix separation and pre-concentration of trace levels of metals in troublesome matrices. Rather than being comprehensive this review is aimed at outlining the pros and cons via representative examples of recent attempts in automating green sample preparation procedures in an FI or sequential injection (SI) mode capitalizing on single-drop microextraction, dispersive liquid-phase microextraction and advanced sorptive materials including carbon and metal oxide nanoparticles, ion imprinted polymers, superparamagnetic nanomaterials and biological/biomass sorbents. Current challenges in the field are identified and the synergetic combination of flow analysis, nanotechnology and metal-tagged biomolecule detection is envisaged.

  4. 7 CFR 52.38b - Statistical sampling procedures for on-line inspection by attributes of processed fruits and...

    Science.gov (United States)

    2010-01-01

    ... PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1... by attributes of processed fruits and vegetables. 52.38b Section 52.38b Agriculture Regulations of...-line inspection by attributes of processed fruits and vegetables. (a) General. The Cumulative...

  5. Looking into individual coffee beans during the roasting process: direct micro-probe sampling on-line photo-ionisation mass spectrometric analysis of coffee roasting gases.

    Science.gov (United States)

    Hertz-Schünemann, Romy; Streibel, Thorsten; Ehlert, Sven; Zimmermann, Ralf

    2013-09-01

    A micro-probe (μ-probe) gas sampling device for on-line analysis of gases evolving in confined, small objects by single-photon ionisation time-of-flight mass spectrometry (SPI-TOFMS) was developed. The technique is applied for the first time in a feasibility study to record the formation of volatile and flavour compounds during the roasting process within (inside) or in the direct vicinity (outside) of individual coffee beans. A real-time on-line analysis of evolving volatile and semi-volatile organic compounds (VOC and SVOC) as they are formed under the mild pyrolytic conditions of the roasting process was performed. The soft-ionisation mass spectra depict a molecular ion signature, which is well corresponding with the existing knowledge of coffee roasting and evolving compounds. Additionally, thereby it is possible to discriminate between Coffea arabica (Arabica) and Coffea canephora (Robusta). The recognized differences in the roasting gas profiles reflect the differences in the precursor composition of the coffee cultivars very well. Furthermore, a well-known set of marker compounds for Arabica and Robusta, namely the lipids kahweol and cafestol (detected in their dehydrated form at m/z 296 and m/z 298, respectively) were observed. If the variation in time of different compounds is observed, distinctly different evolution behaviours were detected. Here, phenol (m/z 94) and caffeine (m/z 194) are exemplary chosen, whereas phenol shows very sharp emission peaks, caffeine do not have this highly transient behaviour. Finally, the changes of the chemical signature as a function of the roasting time, the influence of sampling position (inside, outside) and cultivar (Arabica, Robusta) is investigated by multivariate statistics (PCA). In summary, this pilot study demonstrates the high potential of the measurement technique to enhance the fundamental knowledge of the formation processes of volatile and semi-volatile flavour compounds inside the individual coffee bean.

  6. On-line sample treatment - Capillary gas chromatography

    NARCIS (Netherlands)

    Goosens, EC; de Jong, D; de Jong, GJ; Brinkman, UAT

    1998-01-01

    Sample pretreatment is often the bottleneck of a trace level analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of procedu

  7. On-line characterization of a hybridoma cell culture process.

    Science.gov (United States)

    Zhou, W; Hu, W S

    1994-06-20

    The on-line determination of the physiological state of a cell culture process requires reliable on-line measurements of various parameters and calculations of specific rates from these measurements. The cell concentration of a hybridoma culture was estimated on-line by measuring optical density (OD) with a laser turbidity probe. The oxygen uptake rate (OUR) was determined by monitoring dynamically dissolved oxygen concentration profiles and closing oxygen balances in the culture. The base addition for neutralizing lactate produced by cells was also monitored on-line via a balance. Using OD and OUR measurements, the specific growth and specific oxygen consumption rates were determined on-line. By combining predetermined stoichiometric relationships among oxygen and glucose consumption and lactate production, the specific glucose consumption and lactate production rates were also calculated on-line. Using these on-line measurements and calculations, the hybridoma culture process was characterized on-line by identifying the physiological states. They will also facilitate the implementation of nutrient feeding strategies for fed-batch and perfusion cultures. (c) 1994 John Wiley & Sons, Inc.

  8. The Efficiency of the On-line Samplings

    Directory of Open Access Journals (Sweden)

    Ileana Gabriela NICULESCU-ARON

    2006-01-01

    Full Text Available The rapid growth of the technology from the last decades led to the collateral development of many other sciences. One of the most important inventions was the Internet and the web technologies with a tremendous impact on the society. Statistics, as a social science, at its turn in ongoing development has only to gain from that. Lately, the on line sampling technique greatly developed. Each web site of a certain importance includes in various forms of the questionnaires. These vary from a mere question to lengthy ones and are a part of daily life of those who access the World Wide Web. The main question is how feasible are the results derived from these samplings as the main issue is the representativiness. A nonrepresentative sampling is a futile one. It is a more convenient solution to post a question on the web page and to wait for an answer from the page’s visitors? But how representative is this answer for the target audience? The present paper aims to list the on-lone methodology as well as analyze their efficiency through presenting their advantages and drawbacks.

  9. Semi-on-line analysis for fast and precise monitoring of bioreaction processes

    DEFF Research Database (Denmark)

    Christensen, L.H.; Marcher, J.; Schulze, Ulrik

    1996-01-01

    Monitoring of substrates and products during fermentation processes can be achieved either by on-line, in situ sensors or by semi-on-line analysis consisting of an automatic sampling step followed by an ex situ analysis of the retrieved sample. The potential risk of introducing time delays...... and signal bias during sampling makes it necessary to distinguish between real-time, on-line, in situ methods and semi-on-line analysis. In addition, semi-on-line analyzers are often mechanically complex-a circumstance which has to be given special attention during their industrial use on a routine basis....... This review on semi-on-line analysis will focus both on the dynamics and precision of aseptic sampling devices and on the performance of flow injection analysis (FIA) and sequential injection analysis (SIA), especially with regard to their robustness when used in industry. (C) 1996 John Wiley & Sons, Inc....

  10. ADAPTIVE CONTEXT PROCESSING IN ON-LINE HANDWRITTEN CHARACTER RECOGNITION

    NARCIS (Netherlands)

    Iwayama, N.; Ishigaki, K.

    2004-01-01

    We propose a new approach to context processing in on-line handwritten character recognition (OLCR). Based on the observation that writers often repeat the strings that they input, we take the approach of adaptive context processing. (ACP). In ACP, the strings input by a writer are automatically

  11. Robust on-line monitoring of biogas processes; Robusta maettekniker on-line foer optimerad biogasproduktion

    Energy Technology Data Exchange (ETDEWEB)

    Nordberg, Aake; Hansson, Mikael; Kanerot, Mija; Krozer, Anatol; Loefving, Bjoern; Sahlin, Eskil

    2010-03-15

    project showed that pH-adjustment with Na{sub 3}PO{sub 4} can be a way of compensating for the losses of volatile compounds (up to 20% of VS), which occurs when standardized reference methods are used. This is a fundamental problem and requires further research. Monitoring of a laboratory-scale anaerobic digester with NIR showed that a previously developed multivariate model could predict propionate concentrations (R2= 0,92; RMSEP 0,39 g/L) in the interval 0-5 g/L, which is a relevant interval for inhibition (limit ca 3 g/L). A commercial FT-NIR instrument was subsequently installed at the production plant. However, the organic loading was decreased during the evaluation period due to process disturbances, at which the dynamic of the process was not in the range needed for prediction of e.g. propionate. Measurements and evaluation will continue during normal conditions after the completion of this project. Evaluation of a potentiometric sensor for ammonia with potential for on-line application showed low stability and a need for daily calibration, which therefore did not fulfill the requested demand. The project has demonstrated technologies with significant potential for on-line monitoring at production scale facilities, thus improving the knowledge base for making important decisions. Knowledge about on-line implementation has increased, and important insights into the limitations of standardized reference methods and substrate characteristics have been achieved. Instrument suppliers have in general a limited insight in the conditions at a biogas plant, which suggests that this type of WR-financed project is important for development in the area

  12. Specialization processes in on-line unsupervised learning

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Reents, G.; Schlösser, E.

    1998-01-01

    From the recent analysis of supervised learning by on-line gradient descent in multilayered neural networks it is known that the necessary process of student specialization can be delayed significantly. We demonstrate that this phenomenon also occurs in various models of unsupervised learning. A sol

  13. On-line sample treatment and FT-IR determination of doxylamine succinate in pharmaceuticals.

    Science.gov (United States)

    Ventura-Gayete, Josep F; de la Guardia, Miguel; Garrigues, Salvador

    2006-12-15

    A low solvent consumption method for Fourier transform infrared spectroscopy (FT-IR) determination of doxylamine succinate in pharmaceuticals has been developed. The analyte was continuous and selectively extracted with a 13% (v/v) ethanol:chloroform solvent mixture, recirculating the solvent through the sample and monitoring the process by FT-IR. Doxylamine succinate was determined by on-line standard addition measuring the peak area in the regions 1730-1710 and 1485-1462cm(-1) corrected with a two-point baseline established between 2000 and 1800cm(-1). This new method implies low volumes of chloroformic solvent mixture, only 2.6mL per sample, in front of classical batch FT-IR methods, improving analytical efficiency and reducing waste generation. The on-line extraction and standard addition determination of doxylamine succinate allowed a throughput of 10h(-1).

  14. On-line estimation of concentration parameters in fermentation processes

    Institute of Scientific and Technical Information of China (English)

    XIONG Zhi-hua; HUANG Guo-hong; SHAO Hui-he

    2005-01-01

    It has long been thought that bioprocess, with their inherent measurement difficulties and complex dynamics, posed almost insurmountable problems to engineers. A novel software sensor is proposed to make more effective use of those measurements that are already available, which enable improvement in fermentation process control. The proposed method is based on mixtures of Gaussian processes (GP) with expectation maximization (EM) algorithm employed for parameter estimation of mixture of models. The mixture model can alleviate computational complexity of GP and also accord with changes of operating condition in fermentation processes, i.e., it would certainly be able to examine what types of process-knowledge would be most relevant for local models' specific operating points of the process and then combine them into a global one. Demonstrated by on-line estimate of yeast concentration in fermentation industry as an example, it is shown that soft sensor based state estimation is a powerful technique for both enhancing automatic control performance of biological systems and implementing on-line monitoring and optimization.

  15. Process Analytical Technology and On-Line Spectroscopic Measurements of Chemical Meat Quality

    DEFF Research Database (Denmark)

    Sørensen, Klavs Martin

    This thesis deals with process analytical technology and how it can be implemented in the meat industry through on-line grading of chemical meat quality. The focus will be on two applications, namely the rapid quality control of fat quality and the development of a method for on-line detection of...... quality, but also with environmental issues such as energy and water use and animal welfare. Future research into the technologies will ultimately allow broad on-line screening of biomarkers, leading to on-line metabolomics......This thesis deals with process analytical technology and how it can be implemented in the meat industry through on-line grading of chemical meat quality. The focus will be on two applications, namely the rapid quality control of fat quality and the development of a method for on-line detection...... of boar taint. The chemical makeup of fat has a large effect on meat cut quality. Fat quality has traditionally been determined by methylation of a tissue sample followed by chromatography on a GC-MS system, elucidating the composition of the individual fatty acids. As this procedure typically takes far...

  16. Process Analytical Technology and On-Line Spectroscopic Measurements of Chemical Meat Quality

    DEFF Research Database (Denmark)

    Sørensen, Klavs Martin

    This thesis deals with process analytical technology and how it can be implemented in the meat industry through on-line grading of chemical meat quality. The focus will be on two applications, namely the rapid quality control of fat quality and the development of a method for on-line detection...... of boar taint. The chemical makeup of fat has a large effect on meat cut quality. Fat quality has traditionally been determined by methylation of a tissue sample followed by chromatography on a GC-MS system, elucidating the composition of the individual fatty acids. As this procedure typically takes far...... on surgical castration will be in effect starting 2018. With the ban, the risk of meat products with the malodorous taint reaching the consumer is highly increased, and thus, detection of boar taint is a necessity. No current on-line detection system is available; the only alternative is chemical extraction...

  17. Automation and integration of multiplexed on-line sample preparation with capillary electrophoresis for DNA sequencing

    Energy Technology Data Exchange (ETDEWEB)

    Tan, H.

    1999-03-31

    The purpose of this research is to develop a multiplexed sample processing system in conjunction with multiplexed capillary electrophoresis for high-throughput DNA sequencing. The concept from DNA template to called bases was first demonstrated with a manually operated single capillary system. Later, an automated microfluidic system with 8 channels based on the same principle was successfully constructed. The instrument automatically processes 8 templates through reaction, purification, denaturation, pre-concentration, injection, separation and detection in a parallel fashion. A multiplexed freeze/thaw switching principle and a distribution network were implemented to manage flow direction and sample transportation. Dye-labeled terminator cycle-sequencing reactions are performed in an 8-capillary array in a hot air thermal cycler. Subsequently, the sequencing ladders are directly loaded into a corresponding size-exclusion chromatographic column operated at {approximately} 60 C for purification. On-line denaturation and stacking injection for capillary electrophoresis is simultaneously accomplished at a cross assembly set at {approximately} 70 C. Not only the separation capillary array but also the reaction capillary array and purification columns can be regenerated after every run. DNA sequencing data from this system allow base calling up to 460 bases with accuracy of 98%.

  18. A least mean squares CUBIC algorithm for on-line differential of sampled analog signals

    Science.gov (United States)

    Allum, J. H. J.

    1975-01-01

    A digital computer algorithm is developed for on-line time differentiation of sampled analog voltage signals. The derivative is obtained by employing a least mean squares technique. The recursive algorithm results in a considerable reduction in computer time compared to a complete new solution of the normal equations each time a new data point is accepted. Implementation of the algorithm on a digital computer is discussed. Examples are simulated on a DEC PDP-8 computer.

  19. The Process Controller for the LHCb On-LIne Farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2007-01-01

    The Process Controller is a tool of the LHCb FMC (Farm Monitoring and Control System) in charge of keeping a list of applications up and running on the farm nodes. It tipically runs on a few control PCs each one watching ~200 farm nodes and performs its task by maintaining the list of scheduled applications for each controlled farm node and by interacting with the Task Manager Servers running on the farm nodes to start processes, to obtain the notification of process termination, to re-spawn the terminated processes (if requested) and to stop processes. Processes can be added to or removed from the scheduled application list for one or more nodes by means of DIM commands, while DIM services provide the list of scheduled applications for each controlled farm node together with their properties, the number of re-spawns and the re-spawn times.

  20. Quantitative on-line concentration for capillary electrophoresis with inkjet sample introduction technique.

    Science.gov (United States)

    Rang, Ying; Zeng, Hulie; Nakajima, Hizuru; Kato, Shungo; Uchiyama, Katsumi

    2015-08-01

    A quantitative sample introduction method based upon inkjet injection was applied to capillary electrophoresis coupled with stacking and sweeping on-line concentration techniques. Methylxanthines were used as model compounds for the proof-of-concept of the method. The volume of injected sample could be easily manipulated by controlling the number of ejected droplets in the injection procedure. Under optimized conditions, a linear relationship between the ejected droplet number and peak area was obtained when the droplet number introduced into the capillary was less than 100. Under optimized quantitative on-line concentration conditions, the limits of detection for theobromine, caffeine, and theophylline were 1.0, 2.0, and 1.0 μM, respectively. The inkjet injection system was evaluated by comparing it with conventional injection methods. The electropherogram of the inkjet injection mode was the same as that for hydrodynamic injection mode, and no sample discrimination was observed compared with the electrokinetic injection mode. The established method was applied to the determination of methylxanthines in bottled green tea. The recoveries of theobromine, caffeine, and theophylline were 94.1, 110.6, and 86.8%, respectively. We conclude that proposed method can be used for quantitative concentration for capillary electrophoresis, thus resulting in an improved accuracy.

  1. On-Line Monitoring of Fermentation Processes by Near Infrared and Fluorescence Spectroscopy

    DEFF Research Database (Denmark)

    Svendsen, Carina

    Monitoring and control of fermentation processes is important to ensure high product yield, product quality and product consistency. More knowledge on on-line analytical techniques such as near infrared and fluorescence spectroscopy is desired in the fermentation industry to increase the efficiency...... of on-line monitoring systems. The primary aim of this thesis is to elucidate and explore the dynamics in fermentation processes by spectroscopy. Though a number of successful on-line lab-scale monitoring systems have been reported, it seems that several challenges are still met, which limits the number...... for on-line monitoring if corrections or preventive measures during the quantification are carried out. The findings presented in this thesis have enabled the possibility of obtaining a better process understanding and to ease monitoring and controlling of fermentation processes....

  2. On-line spheroidization process of medium-carbon low-alloyed cold heading steel

    Institute of Scientific and Technical Information of China (English)

    Yu Fu; Hao Yu; Pan Tao

    2014-01-01

    Conventionally manufactured 35CrMo cold heading steel must undergo spheroidization annealing before the cold heading process. In this paper, different types of deformation processes with various controlled cooling periods were operated to achieve on-line spheroidal cementite using the Gleeble-3500 simulation technique. According to the measured dynamic ferrite transformation temperature (Ad3), the deformation could be divided into two types:low temperature deformation at 810 and 780°C;“deformation-induced ferrite transformation”(DIFT) deformation at 750 and 720°C. Compared with the low temperature deformation, the DIFT deformation followed by accelerated cooling to 680°C is beneficial for the formation of spheroidal cementite. Samples subjected to both the low-temperature deformation and DIFT deformation can obtain granular bainite by accelerated cooling to 640°C;the latter may contribute to the formation of a fine dispersion of secondary constituents. Granular bainite can transform into globular pearlite rapidly during subcritical annealing, and the more the dis-perse phase, the more homogeneously distributed globular cementite can be obtained.

  3. On-Line Sentence Processing in Swedish: Cross-Linguistic Developmental Comparisons with French

    Science.gov (United States)

    Kail, Michele; Kihlstedt, Maria; Bonnet, Philippe

    2012-01-01

    This study examined on-line processing of Swedish sentences in a grammaticality-judgement experiment within the framework of the Competition Model. Three age groups from 6 to 11 and an adult group were asked to detect grammatical violations as quickly as possible. Three factors concerning cue cost were studied: violation position (early vs. late),…

  4. Extending Practical Pre-Aggregation in On-Line Analytical Processing

    DEFF Research Database (Denmark)

    Pedersen, Torben Bach; Jensen, Christian Søndergaard; Dyreson, Curtis E.

    On-Line Analytical Processing (OLAP) based on a dimensional view of data is being used increasingly in traditional business applications as well as in applications such as health care for the purpose of analyzing very large amounts of data. Pre-aggregation, the prior materialization of aggregate...

  5. On-line monitoring of fermentation processes using multi-wavelength fluorescence

    DEFF Research Database (Denmark)

    Odman, Peter; Petersen, Nanna; Johansen, Claus Lindvald

    2007-01-01

    Fermentation processes often suffer from a lack of real-time methods for on-line determination of variables like the concentrations of nutrients and products. This work aims at investigating the possibilities of implementing an on-line fermentation monitoring system based on multi....... The model system considered in this work is the antibiotic production by Streptomyces coelicolor, a filamentous bacterium. In addition to predicting concentrations of biomass in the fermentation broth, the data allowed detection of different physiological states, i.e. growth phase and phosphate limitation...

  6. Process Identification in On-line Optimizing Control, an Application to a Heat Pump

    Directory of Open Access Journals (Sweden)

    Morten C. Svensson

    1996-10-01

    Full Text Available The objective of this paper is to focus on on-line state and parameter estimation in connection with on-line model-based optimizing control of continuous processes. A nonlinear programming approach is used to estimate unmeasured state variables and parameters in systems modelled by nonlinear differential-algebraic equations. The nonlinear dynamic model is discretized by orthogonal collocation on finite elements, and the moving-horizon approach is used to reduce the dimension of the final optimization problem.

  7. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples

    Directory of Open Access Journals (Sweden)

    Maria Espina-Benitez

    2017-07-01

    Full Text Available A new analytical method coupling a (off-line solid-phase microextraction with an on-line capillary electrophoresis (CE sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE using ultraviolet diode array detection (DAD. Further enhancement of concentration sensitivity detection was achieved by on-line CE “acetonitrile stacking” preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L−1 and 2.91 and 3.86 µg∙L−1, respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers.

  8. On-line coupling of macroporous resin column chromatography with direct analysis in real time mass spectrometry utilizing a surface flowing mode sample holder.

    Science.gov (United States)

    Zeng, Shanshan; Wang, Lu; Chen, Teng; Qu, Haibin

    2014-02-06

    A surface flowing mode sample holder was designed as an alternative sampling strategy for direct analysis in real time mass spectrometry (DART-MS). With the sample holder, the on-line coupling of macroporous resin column chromatography with DART-MS was explored and the new system was employed to monitor the column chromatography elution process of Panax notoginseng. The effluent from macroporous resin column was first diluted and mixed with a derivatization reagent on-line, and the mixture was then directly transferred into the ionization region of DART-MS by the sample holder. Notoginsenosides were methylated and ionized in a metastable helium gas stream, and was introduced into MS for detection. The on-line system showed reasonable repeatability with a relative standard deviation of 12.3% for the peak area. Three notoginsenosides, i.e. notoginsenoside R1, ginsenoside Rb1 and ginsenoside Rg1, were simultaneously determined during the eluting process. The alteration of the chemical composition in the effluent was accurately identified in 9 min, agreeing well with the off-line analysis. The presented technique is more convenient compared to the traditional UPLC method. These results suggest that the surface flowing mode DART-MS has a good potential for the on-line process monitoring in the pharmaceutical industry.

  9. [Analysis of phthalate esters in plastic-packaging bags on-line sample stacking-microemulsion electrokinetic chromatography].

    Science.gov (United States)

    Xiao, Jia; Huang, Ying; Wang, Minyi; Chen, Guonan

    2012-09-01

    Two convenient, effective, and reproducible methods using microemulsion electrokinetic chromatography (MEEKC)-normal stacking mode (NSM) and reversed electrode polarity stacking mode (REPSM) were developed for the on-line sample stacking of phthalate esters (PAEs). REPSM coupled with MEEKC increased the sensitivity of 937.5 to 7,143 times for four PAEs compared to the conventional MEEKC. The separating conditions in the MEEKC method were studied, and many factors influencing the two sample stacking processes were investigated in detail. The optimum sample matrices for the two stacking methods were as follows: 30 mmol/L sodium cholate (SC) and 30.0 mmol/L borate (pH 8.5). Additionally, sample injections as large as 3.45 kPa x 40 s and 3.45 kPa x 90 s were applied for NSM-MEEKC and REPSM-MEEKC, respectively. The linear relationship and reproducibility were also examined. Under the optimum conditions, the detection limits (S/N = 3) of the PAEs were in the ranges of 0.021 - 0.33 mg/L and 0.7 - 4 microg/L for NSM-MEEKC and REPSM-MEEKC, respectively. The proposed REPSM-MEEKC has been successfully applied to determine PAEs in plastic-packaging bags, and the spiked recoveries were in the range of 89.1% - 105.6% with satisfactory results.

  10. On-line monitoring of pharmaceutical production processes using Hidden Markov Model.

    Science.gov (United States)

    Zhang, Hui; Jiang, Zhuangde; Pi, J Y; Xu, H K; Du, R

    2009-04-01

    This article presents a new method for on-line monitoring of pharmaceutical production process, especially the powder blending process. The new method consists of two parts: extracting features from the Near Infrared (NIR) spectroscopy signals and recognizing patterns from the features. Features are extracted from spectra by using Partial Least Squares method (PLS). The pattern recognition is done by using Hidden Markov Model (HMM). A series of experiments are conducted to evaluate the effectiveness of this new method. In the experiments, wheat powder and corn powder are blended together at a set concentration. The proposed method can effectively detect the blending uniformity (the success rate is 99.6%). In comparison to the conventional Moving Block of Standard Deviation (MBSD), the proposed method has a number of advantages, including higher reliability, higher robustness and more transparent decision making. It can be used for effective on-line monitoring of pharmaceutical production processes.

  11. On-line calibration of process instrumentation channels in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hashemian, H.M.; Farmer, J.P. [Analysis and Measurement Services Corp., Knoxville, TN (United States)

    1995-04-01

    An on-line instrumentation monitoring system was developed and validated for use in nuclear power plants. This system continuously monitors the calibration status of instrument channels and determines whether or not they require manual calibrations. This is accomplished by comparing the output of each instrument channel to an estimate of the process it is monitoring. If the deviation of the instrument channel from the process estimate is greater than an allowable limit, then the instrument is said to be {open_quotes}out of calibration{close_quotes} and manual adjustments are made to correct the calibration. The success of the on-line monitoring system depends on the accuracy of the process estimation. The system described in this paper incorporates both simple intercomparison techniques as well as analytical approaches in the form of data-driven empirical modeling to estimate the process. On-line testing of the calibration of process instrumentation channels will reduce the number of manual calibrations currently performed, thereby reducing both costs to utilities and radiation exposure to plant personnel.

  12. [Research on quality parameters of scutellariae radix (formula particles) using on-line NIR in pilot with different extraction process].

    Science.gov (United States)

    Li, Yang; Wu, Zhi-Sheng; Shi, Xin-Yuan; Pan, Xiao-Ning; Zhang, Qiao; Qiao, Yan-Jiang

    2014-10-01

    The on-line monitor for the changes in the content of baicalin in Scutellariae Radix formula particles during the extraction process was conducted by using near infrared spectroscopy (NIR). High performance liquid chromatography (HPLC) was used as a reference method. Kennard-Stone (KS) was used to divide sample sets, so as to compare different pretreatment methods. The synergy interval partial least squares (SiPLS) was used to screen out modeling wave band to establish partial least-squares models. The relative error method was applied to predict forecast set samples of Scutellariae Radix in three extraction phases. The results showed that the model established by Savitzky-Golay smoothing with 11 points (SG11 points) was the best, with the root mean square with cross validation (RMSECV), root mean square error of correction (RMSEC) and root mean square error of prediction (RMSEP) of baicalin of 0.092 7, 0.134 4 and 0.114 8, respectively, the determination coefficient R2 of greater than 0.99, and the relative error of baicalin content of less than 5%. This indicates that the on-line near infrared reflectance spectroscopy could be applied in on-line monitor and quality control of the extraction process of Scutellariae Radix formula particles.

  13. An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation

    NARCIS (Netherlands)

    Wagner, K.; Miliotis, T.; Marko-Varga, G; Bischoff, Rainer; Unger, K.K.

    2002-01-01

    A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary techniqu

  14. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments...

  15. On-line Batch Process Monitoring and Diagnosing Based on Fisher Discriminant Analysis

    Institute of Scientific and Technical Information of China (English)

    ZHAO Xu; SHAO Hui-he

    2006-01-01

    A new on-line batch process monitoring and diagnosing approach based on Fisher discriminant analysis (FDA) was proposed. This method does not need to predict the future observations of variables, so it is more sensitive to fault detection and stronger implement for monitoring. In order to improve the monitoring performance,the variables trajectories of batch process are separated into several blocks. The key to the proposed approach for on-line monitoring is to calculate the distance of block data that project to low-dimension Fisher space between new batch and reference batch. Comparing the distance with the predefine threshold, it can be considered whether the batch process is normal or abnormal. Fault diagnosis is performed based on the weights in fault direction calculated by FDA. The proposed method was applied to the simulation model of fed-batch penicillin fermentation and the results were compared with those obtained using MPCA. The simulation results clearly show that the on-line monitoring method based on FDA is more efficient than the MPCA.

  16. On-line monitoring of the crystallization process: relationship between crystal size and electrical impedance spectra

    Science.gov (United States)

    Zhao, Yanlin; Yao, Jun; Wang, Mi

    2016-07-01

    On-line monitoring of crystal size in the crystallization process is crucial to many pharmaceutical and fine-chemical industrial applications. In this paper, a novel method is proposed for the on-line monitoring of the cooling crystallization process of L-glutamic acid (LGA) using electrical impedance spectroscopy (EIS). The EIS method can be used to monitor the growth of crystal particles relying on the presence of an electrical double layer on the charged particle surface and the polarization of double layer under the excitation of alternating electrical field. The electrical impedance spectra and crystal size were measured on-line simultaneously by an impedance analyzer and focused beam reflectance measurement (FBRM), respectively. The impedance spectra were analyzed using the equivalent circuit model and the equivalent circuit elements in the model can be obtained by fitting the experimental data. Two equivalent circuit elements, including capacitance (C 2) and resistance (R 2) from the dielectric polarization of the LGA solution and crystal particle/solution interface, are in relation with the crystal size. The mathematical relationship between the crystal size and the equivalent circuit elements can be obtained by a non-linear fitting method. The function can be used to predict the change of crystal size during the crystallization process.

  17. On-line Batch Process Monitoring with Improved Multi-way Independent Component Analysis

    Institute of Scientific and Technical Information of China (English)

    GUO Hui; LI Hongguang

    2013-01-01

    In the past decades,on-line monitoring of batch processes using multi-way independent component analysis (MICA) has received considerable attention in both academia and industry.This paper focuses on two troublesome issues concerning selecting dominant independent components without a standard criterion and determining the control limits of monitoring statistics in the presence of non-Gaussian distribution.To optimize the number of key independent components,we introduce a novel concept of system deviation,which is able to evaluate the reconstructed observations with different independent components.The monitored statistics are transformed to Gaussian distribution data by means of Box-Cox transformation,which helps readily determine the control limits.The proposed method is applied to on-line monitoring of a fed-batch penicillin fermentation simulator,and the experimental results indicate the advantages of the improved MICA monitoring compared to the conventional methods.

  18. Rapid, one-pot derivatization and distillation of chlorophenols from solid samples with their on-line enrichment.

    Science.gov (United States)

    Ganeshjeevan, R; Chandrasekar, Raghavan; Kadigachalam, Parasuraman; Radhakrishnan, Ganga

    2007-01-26

    A microwave-assisted steam distillation (MASD) sample preparation technique for extracting chlorophenols from solid samples was studied. This open vessel microwave system based study developed as an integrated method since it has incorporated extractive distillation, derivatization and on-line enrichment. Gas chromatography (GC) with electron-capture detection was used for the analysis. The study involved optimization of MASD parameters and on-line enrichments using spiked solid samples. MASD achieved recoveries for spiked soil samples in the range of 94-101% within 20min with a collection of only 20ml distillate facilitating on-line enrichment. Some real samples were analyzed that included soil, wood, leather, textiles, dyes and certified reference materials of soil and wood samples. Limit of detection values of 12ng/g for pentachlorophenol and 194ng/g for monochlorophenol were found. Recoveries of 96.6% in the case of soil certified reference material (CRM) with RSD 2.7% and 80.6% in the case of wood CRM with RSD 3.3% were observed in this study. MASD studied found to produce very clean extracts in comparison to reference techniques.

  19. On-line Dynamic Model Correction Based Fault Diagnosis in Chemical Processes

    Institute of Scientific and Technical Information of China (English)

    田文德; 孙素莉

    2007-01-01

    A novel fault detection and diagnosis method was proposed,using dynamic simulation to monitor chemical process and identify faults when large tracking deviations occur.It aims at parameter failures,and the parameters are updated via on-line correction.As it can predict the trend of process and determine the existence of malfunctions simultaneously,this method does not need to design problem-specific observer to estimate unmeasured state variables.Application of the proposed method is presented on one water tank and one aromatization reactor,and the results are compared with those from the traditional method.

  20. Analysis of hexavalent chromium in Colla corii asini with on-line sample pretreatment valve-switching ion chromatography.

    Science.gov (United States)

    Yang, Yuling; He, Jie; Huang, Zhongping; Zhong, Naifei; Zhu, Zuoyi; Jiang, Renyu; You, Jinghua; Lu, Xiuyang; Zhu, Yan; He, Shiwei

    2013-08-30

    An ion chromatography (IC) system with on-line sample pretreatment using valve-switching technique was developed for the determination of hexavalent chromium (Cr(VI)) in Colla corii asini. Colla corii asini is a complicated sample with organics as main matrix. In this work, a polymer-based reversed-phase column was used as a pretreatment column. Via valve-switching technique, sample solution with target ions were eluted from a collection loop to analytical columns, with matrix eliminated on-line. Under the optimized separation conditions, the method showed good linearity (r=0.9998) in the range of 0.004-1.0mg/L and satisfactory repeatability (RSD<3%, n=6). The limit of detection (LOD) was 1.4μg/L (S/N=3). The average spiked recoveries of Cr(VI) were 93.4-102.0%. The result showed that the on-line sample pretreatment IC system was convenient and practical for the determination of trace Cr(VI) in Colla corii asini samples.

  1. Validation of a high performance liquid chromatography analysis for the determination of noradrenaline and adrenaline in human urine with an on-line sample purification

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Kristiansen, J; Nielsen, J L

    1999-01-01

    A high performance liquid chromatography (HPLC) method with fluorescence detection including an on-line purification was established for determination of catecholamines in human urine. The method was evaluated using samples of pooled urine spiked with catecholamines and validated for measurements...... deviation of the method was sufficiently low to distinguish between persons working with two different processes of garbage collection, i.e. collection using four wheeled containers versus collection using bins....

  2. Web Data Cube Construction in Multidimensional On-line Analytical Processing Environment

    Institute of Scientific and Technical Information of China (English)

    ZHU Yan

    2007-01-01

    This paper investigates how to integrate Web data into a multidimensional data warehouse (cube) for comprehensive on-line analytical processing (OLAP) and decision making. An approach for Web data-based cube construction is proposed, which includes Web data modeling based on MIX (Metadata based Integration model for data X-change), generic and specific mapping rules design, and a transformation algorithm for mapping Web data to a multidimensional array. Besides, the structure and implementation of the prototype of a Web data base cube are discussed.

  3. Virtual Sensors for On-line Wheel Wear and Part Roughness Measurement in the Grinding Process

    Directory of Open Access Journals (Sweden)

    Ander Arriandiaga

    2014-05-01

    Full Text Available Grinding is an advanced machining process for the manufacturing of valuable complex and accurate parts for high added value sectors such as aerospace, wind generation, etc. Due to the extremely severe conditions inside grinding machines, critical process variables such as part surface finish or grinding wheel wear cannot be easily and cheaply measured on-line. In this paper a virtual sensor for on-line monitoring of those variables is presented. The sensor is based on the modelling ability of Artificial Neural Networks (ANNs for stochastic and non-linear processes such as grinding; the selected architecture is the Layer-Recurrent neural network. The sensor makes use of the relation between the variables to be measured and power consumption in the wheel spindle, which can be easily measured. A sensor calibration methodology is presented, and the levels of error that can be expected are discussed. Validation of the new sensor is carried out by comparing the sensor’s results with actual measurements carried out in an industrial grinding machine. Results show excellent estimation performance for both wheel wear and surface roughness. In the case of wheel wear, the absolute error is within the range of microns (average value 32 μm. In the case of surface finish, the absolute error is well below Ra 1 μm (average value 0.32 μm. The present approach can be easily generalized to other grinding operations.

  4. 7 CFR 42.140 - Operating Characteristic (OC) curves for on-line sampling and inspection.

    Science.gov (United States)

    2010-01-01

    ... defects in the sample. (e) The next plan that is listed in the column headed 6 for an AQL of 0.25 is a... total sample, the lot will be rejected. The other double sampling plans operate in a similar manner with... AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF...

  5. Improving science literacy: The knowledge-transforming process within an on-line professional development project

    Science.gov (United States)

    Sherwood, Susan A.

    2008-10-01

    This study examined connections between science literacy and writing. Science e-mails were written as content-oriented professional development materials for K-8 teachers. E-mail drafts underwent multiple revisions. The study data included drafts, final e-mails, and feedback from the supervising scientist and the e-mails' teacher audience. The analyses, informed by Bereiter & Scardamalia's knowledge-transforming process (1987), Schindler's audience theories (2001), and Johnson and Aragon's on-line instruction framework (2003), sought connections among three components: the writer's struggle between content and discourse, audience, and format. The e-mail drafts indicated a large percentage of text changes involving two or more of the components, primarily concerning discourse. Redundancies surfaced among the components, indicating Bereiter and Scardamalia's knowledge-transforming process sufficiently explained the e-mail project; additional format and audience models were unnecessary. Recommendations for extending the knowledge-transforming process specifically for science are included.

  6. On-line Fault Diagnosis in Industrial Processes Using Variable Moving Window and Hidden Markov Model

    Institute of Scientific and Technical Information of China (English)

    周韶园; 谢磊; 王树青

    2005-01-01

    An integrated framework is presented to represent and classify process data for on-line identifying abnormal operating conditions. It is based on pattern recognition principles and consists of a feature extraction step, by which wavelet transform and principal component analysis are used to capture the inherent characteristics from process measurements, followed by a similarity assessment step using hidden Markov model (HMM) for pattern comparison. In most previous cases, a fixed-length moving window was employed to track dynamic data, and often failed to capture enough information for each fault and sometimes even deteriorated the diagnostic performance. A variable moving window, the length of which is modified with time, is introduced in this paper and case studies on the Tennessee Eastman process illustrate the potential of the proposed method.

  7. Combining On-Line Characterization Tools with Modern Software Environments for Optimal Operation of Polymerization Processes

    Directory of Open Access Journals (Sweden)

    Navid Ghadipasha

    2016-02-01

    Full Text Available This paper discusses the initial steps towards the formulation and implementation of a generic and flexible model centric framework for integrated simulation, estimation, optimization and feedback control of polymerization processes. For the first time it combines the powerful capabilities of the automatic continuous on-line monitoring of polymerization system (ACOMP, with a modern simulation, estimation and optimization software environment towards an integrated scheme for the optimal operation of polymeric processes. An initial validation of the framework was performed for modelling and optimization using literature data, illustrating the flexibility of the method to apply under different systems and conditions. Subsequently, off-line capabilities of the system were fully tested experimentally for model validations, parameter estimation and process optimization using ACOMP data. Experimental results are provided for free radical solution polymerization of methyl methacrylate.

  8. Automated analysis of heterogeneous carbon nanostructures by high-resolution electron microscopy and on-line image processing

    Energy Technology Data Exchange (ETDEWEB)

    Toth, P., E-mail: toth.pal@uni-miskolc.hu [Department of Chemical Engineering, University of Utah, 50 S. Central Campus Drive, Salt Lake City, UT 84112-9203 (United States); Farrer, J.K. [Department of Physics and Astronomy, Brigham Young University, N283 ESC, Provo, UT 84602 (United States); Palotas, A.B. [Department of Combustion Technology and Thermal Energy, University of Miskolc, H3515, Miskolc-Egyetemvaros (Hungary); Lighty, J.S.; Eddings, E.G. [Department of Chemical Engineering, University of Utah, 50 S. Central Campus Drive, Salt Lake City, UT 84112-9203 (United States)

    2013-06-15

    High-resolution electron microscopy is an efficient tool for characterizing heterogeneous nanostructures; however, currently the analysis is a laborious and time-consuming manual process. In order to be able to accurately and robustly quantify heterostructures, one must obtain a statistically high number of micrographs showing images of the appropriate sub-structures. The second step of analysis is usually the application of digital image processing techniques in order to extract meaningful structural descriptors from the acquired images. In this paper it will be shown that by applying on-line image processing and basic machine vision algorithms, it is possible to fully automate the image acquisition step; therefore, the number of acquired images in a given time can be increased drastically without the need for additional human labor. The proposed automation technique works by computing fields of structural descriptors in situ and thus outputs sets of the desired structural descriptors in real-time. The merits of the method are demonstrated by using combustion-generated black carbon samples. - Highlights: ► The HRTEM analysis of heterogeneous nanostructures is a tedious manual process. ► Automatic HRTEM image acquisition and analysis can improve data quantity and quality. ► We propose a method based on on-line image analysis for the automation of HRTEM image acquisition. ► The proposed method is demonstrated using HRTEM images of soot particles.

  9. Sample Data Processing.

    Science.gov (United States)

    1982-08-01

    the relative practicality of compensating the channel with an approach of predistorting the masking sequence, by processing in a filter that...replicates the channel response, with a conventional approach of equal- izing the channel with an inverse filter. The predistortion method demonstrated a...compensate for the channel distortion is to predistort the encryption stream in the receiver by means of a fil- ter which replicates the impulse response of

  10. 7 CFR 42.143 - Operating Characteristic (OC) curves for on-line sampling and inspection.

    Science.gov (United States)

    2010-01-01

    ... AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE... plans provided in subpart D. The OC curve and the corresponding cumulative sum sampling plans are listed by AQL. (b) Different plan parameters used to make acceptance and rejection decisions are...

  11. Automated Protein Biomarker Analysis: on-line extraction of clinical samples by Molecularly Imprinted Polymers

    Science.gov (United States)

    Rossetti, Cecilia; Świtnicka-Plak, Magdalena A.; Grønhaug Halvorsen, Trine; Cormack, Peter A. G.; Sellergren, Börje; Reubsaet, Léon

    2017-03-01

    Robust biomarker quantification is essential for the accurate diagnosis of diseases and is of great value in cancer management. In this paper, an innovative diagnostic platform is presented which provides automated molecularly imprinted solid-phase extraction (MISPE) followed by liquid chromatography-mass spectrometry (LC-MS) for biomarker determination using ProGastrin Releasing Peptide (ProGRP), a highly sensitive biomarker for Small Cell Lung Cancer, as a model. Molecularly imprinted polymer microspheres were synthesized by precipitation polymerization and analytical optimization of the most promising material led to the development of an automated quantification method for ProGRP. The method enabled analysis of patient serum samples with elevated ProGRP levels. Particularly low sample volumes were permitted using the automated extraction within a method which was time-efficient, thereby demonstrating the potential of such a strategy in a clinical setting.

  12. Automated Protein Biomarker Analysis: on-line extraction of clinical samples by Molecularly Imprinted Polymers

    Science.gov (United States)

    Rossetti, Cecilia; Świtnicka-Plak, Magdalena A.; Grønhaug Halvorsen, Trine; Cormack, Peter A.G.; Sellergren, Börje; Reubsaet, Léon

    2017-01-01

    Robust biomarker quantification is essential for the accurate diagnosis of diseases and is of great value in cancer management. In this paper, an innovative diagnostic platform is presented which provides automated molecularly imprinted solid-phase extraction (MISPE) followed by liquid chromatography-mass spectrometry (LC-MS) for biomarker determination using ProGastrin Releasing Peptide (ProGRP), a highly sensitive biomarker for Small Cell Lung Cancer, as a model. Molecularly imprinted polymer microspheres were synthesized by precipitation polymerization and analytical optimization of the most promising material led to the development of an automated quantification method for ProGRP. The method enabled analysis of patient serum samples with elevated ProGRP levels. Particularly low sample volumes were permitted using the automated extraction within a method which was time-efficient, thereby demonstrating the potential of such a strategy in a clinical setting. PMID:28303910

  13. Automated on-line preconcentration of palladium on different sorbents and its determination in environmental samples.

    Science.gov (United States)

    Sánchez Rojas, Fuensanta; Bosch Ojeda, Catalina; Cano Pavón, José Manuel

    2007-01-01

    The determination of noble metals in environmental samples is of increasing importance. Palladium is often employed as a catalyst in chemical industry and is also used with platinum and rhodium in motor car catalytic converters which might cause environmental pollution problems. Two different sorbents for palladium preconcentration in different samples were investigated: silica gel functionalized with 1,5-bis(di-2-pyridyl)methylene tbiocarbohydrazide (DPTH-gel) and [1,5-Bis(2-pyridyl)-3-sulphophenyI methylene thiocarbonohydrazide (PSTH) immobilised on an anion-exchange resin (Dowex lx8-200)]. The sorbents were tested in a micro-column, placed in the auto-sampler arm, at the flow rate 2.8 mL min(-1). Elution was performed with 4 M HCl and 4 M HNO3, respectively. Satisfactory results were obtained for two sorbents.

  14. IWTU Process Sample Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Nick Soelberg

    2013-04-01

    CH2M-WG Idaho (CWI) requested that Battelle Energy Alliance (BEA) analyze various samples collected during June – August 2012 at the Integrated Waste Treatment Facility (IWTU). Samples of IWTU process materials were collected from various locations in the process. None of these samples were radioactive. These samples were collected and analyzed to provide more understanding of the compositions of various materials in the process during the time of the process shutdown that occurred on June 16, 2012, while the IWTU was in the process of nonradioactive startup.

  15. A Novel Multi-Secret Sharing Approach for Secure Data Warehousing and On-Line Analysis Processing in the Cloud

    OpenAIRE

    Attasena, Varunya; Harbi, Nouria; Darmont, Jérôme

    2015-01-01

    International audience; Cloud computing helps reduce costs, increase business agility and deploy solutions with a high return on investment for many types of applications, including data warehouses and on-line analytical processing. However, storing and transferring sensitive data into the cloud raises legitimate security concerns. In this paper, we propose a new multi-secret sharing approach for deploying data warehouses in the cloud and allowing on-line analysis processing, while enforcing ...

  16. A Novel Multi-Secret Sharing Approach for Secure Data Warehousing and On-Line Analysis Processing in the Cloud

    OpenAIRE

    Attasena, Varunya; Harbi, Nouria; Darmont, Jérôme

    2017-01-01

    Cloud computing helps reduce costs, increase business agility and deploy solutions with a high return on investment for many types of applications, including data warehouses and on-line analytical processing. However, storing and transferring sensitive data into the cloud raises legitimate security concerns. In this paper, we propose a new multi-secret sharing approach for deploying data warehouses in the cloud and allowing on-line analysis processing, while enforcing data privacy, integrity ...

  17. Continuous on-line determination of methyl tert-butyl ether in water samples using ion mobility spectrometry.

    Science.gov (United States)

    Borsdorf, H; Rämmler, A

    2005-04-22

    A rapid analytical procedure for the on-line determination of methyl tert-butyl ether (MTBE) in water samples was developed. A new membrane extraction unit was used to extract the MTBE from water samples. The concentration of MTBE was determined using ion mobility spectrometry with 63Ni ionization and corona discharge ionization without chromatographic separation. Both ionization methods permit the sensitive determination of MTBE. A detection limit of 100 microg/L was established for the on-line procedure. Neither the inorganic compounds, humic substances nor gasoline were found to exert a significant influence on the peak intensity of the MTBE. The screening procedure can be used for concentrations of monoaromatic compounds (benzene, toluene, xylene) up to 600 microg/L. No sample preparation is required and the analysis results are available within 5 min. In order to determine concentrations between 10 microg/L and 100 microg/L, a discontinuous procedure was developed on the basis of the same experimental set-up.

  18. On-line digital holographic measurement of size and shape of microparticles for crystallization processes

    Science.gov (United States)

    Khanam, Taslima; Darakis, Emmanouil; Rajendran, Arvind; Kariwala, Vinay; Asundi, Anand K.; Naughton, Thomas J.

    2008-09-01

    Crystallization is a widely used chemical process that finds applications in pharmaceutical industries. In an industrial crystallization process, it is not only important to produce pure crystals but also to control the shape and size of the crystals, as they affect the efficiency of downstream processes and the dissolution property of the drug. The effectiveness of control algorithms depend on the availability of on-line, real-time information about these critical properties. In this paper, we investigate the use of lens-less in-line digital holographic microscopy for size and shape measurements for crystallization processes. For this purpose, we use non-crystalline spherical microparticles and carbon fibers with known sizes present in a liquid suspension as test systems. We propose an algorithm to extract size and shape information for a population of microparticles from the experimentally recorded digital holograms. The measurements obtained from the proposed method show good agreement with the corresponding known size and shape of the particles.

  19. Using mark–recapture distance sampling methods on line transect surveys

    Science.gov (United States)

    Burt, Louise M.; Borchers, David L.; Jenkins, Kurt J.; Marques, Tigao A

    2014-01-01

    Mark–recapture distance sampling (MRDS) methods are widely used for density and abundance estimation when the conventional DS assumption of certain detection at distance zero fails, as they allow detection at distance zero to be estimated and incorporated into the overall probability of detection to better estimate density and abundance. However, incorporating MR data in DS models raises survey and analysis issues not present in conventional DS. Conversely, incorporating DS assumptions in MR models raises issues not present in conventional MR. As a result, being familiar with either conventional DS methods or conventional MR methods does not on its own put practitioners in good a position to apply MRDS methods appropriately. This study explains the sometimes subtly different varieties of MRDS survey methods and the associated concepts underlying MRDS models. This is done as far as possible without giving mathematical details – in the hope that this will make the key concepts underlying the methods accessible to a wider audience than if we were to present the concepts via equations.

  20. Evolutionary Control and On-Line Optimization of a MSWC Energy Process

    Directory of Open Access Journals (Sweden)

    Mauro Annunziato

    2006-08-01

    Full Text Available The extensive use of energy generation processes presents a severe challenge to the environment and makes indispensable to focus the research on the maximization of the energy efficiency and minimization of environmental impact like NOx and CO emissions. The proposed idea describes an approach, based on an artificial life environment, for on-line optimization of complex processes for energy production. Such an approach is based on the evolutionary control methodology which, by emulating the mechanism of the biological evolution, composes the capability of sophisticated models with the continuous learning. In order to work with MSWC (Municipal Solid Waste Combustion it was necessary to improve the stability of the optimizer to obtain a good compromise between stability and reactivity. In this way, a specific MSWI performance function has been properly defined in order to quantitatively characterize the current status of the process. The evolutionary control approach has been successfully tested on a MSWC simulator and subsequently installed on a real MWSC plant which produce electricity and heat for a small Italian town (Ferrara. The paper reports the first promising experimental tests on the real plant for optimization of energetic efficiency and pollutant emission reduction.

  1. Evolutionary Control and On-Line Optimization of a MSWC Energy Process

    Directory of Open Access Journals (Sweden)

    Mauro Annunziato

    2006-08-01

    Full Text Available The extensive use of energy generation processes presents a severe challenge to the environment and makes indispensable to focus the research on the maximization of the energy efficiency and minimization of environmental impact like NOx and CO emissions. The proposed idea describes an approach, based on an artificial life environment, for on-line optimization of complex processes for energy production. Such an approach is based on the evolutionary control methodology which, by emulating the mechanism of the biological evolution, composes the capability of sophisticated models with the continuous learning. In order to work with MSWC (Municipal Solid Waste Combustion it was necessary to improve the stability of the optimizer to obtain a good compromise between stability and reactivity. In this way, a specific MSWI performance function has been properly defined in order to quantitatively characterize the current status of the process. The evolutionary control approach has been successfully tested on a MSWC simulator and subsequently installed on a real MWSC plant which produce electricity and heat for a small Italian town (Ferrara. The paper reports the first promising experimental tests on the real plant for optimization of energetic efficiency and pollutant emission reduction.

  2. Determination of triazine herbicide residues in water samples by on-line sweeping concentration in micellar electrokinetic chromatography

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A new method for the determination of atrazine, simazine and prometryn in water samples by on-line sweeping concentration technique in micellar electrokinetic chromatography (MEKC) was developed. Various parameters affecting sample enrichment and separation efficiency were systematically studied. Compared with the conventional MEKC method, up to 60-200-fold improve-merit in concentration sensitivity was achieved in terms of peak height by using this sweeping injection technique. The compound strychnine was used as the internal standard for the improvement of the experimental reproducibility. The limits of detection (S/ N = 3:1) for atrazine, simazine and prometryn were 9, 10 and 0.5 ng mL-1, respectively. This method has been successfully applied to the analysis of atrazine, simazine and prometryn in lake, steam and ground water.

  3. Processing of situational information in story problem texts. An analysis from on-line measures.

    Science.gov (United States)

    Orrantia, Josetxu; Muñez, David; Vicente, Santiago; Verschaffel, Lieven; Rosales, Javier

    2014-01-01

    In three experiments, we investigated the extent to which readers process information related to the construction of a situation model when they are confronted with solving word problems. Considering that generation of inferences to match actions with particular goals is part of constructing of the situation model, we constructed "rich story problems", that is, word problems included in the context of a story, in which the characters propose goals, and then these goals are followed by actions to achieve it. In Experiments 1 and 2 the story problems were designed so that the character's goal was related to the activation of a problem schema, either explicitly (Experiment 1) or implicitly (Experiment 2). In Experiment 3 the problem schema activation was clearly separated from the goal information. In all three experiments, goal information availability was assessed by on-line measures. The results showed that participants processed situational information by keeping track of characters' goals. These results fit nicely with those studies that emphasize the role of situation model construction in word problem solving.

  4. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... a sample liquid comprising the sample and the first preparation system is adapted to receive a receiving liquid. In a particular embodiment, a magnetic sample transport component, such as a permanent magnet or an electromagnet, is arranged to move magnetic beads in between the first and second substrates....

  5. Representative process sampling - in practice

    DEFF Research Database (Denmark)

    Esbensen, Kim; Friis-Pedersen, Hans Henrik; Julius, Lars Petersen

    2007-01-01

    Didactic data sets representing a range of real-world processes are used to illustrate "how to do" representative process sampling and process characterisation. The selected process data lead to diverse variogram expressions with different systematics (no range vs. important ranges; trends and....../or periodicity; different nugget effects and process variations ranging from less than one lag to full variogram lag). Variogram data analysis leads to a fundamental decomposition into 0-D sampling vs. 1-D process variances, based on the three principal variogram parameters: range, sill and nugget effect...

  6. On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples.

    Science.gov (United States)

    Anthemidis, Aristidis N; Ioannou, Kallirroy-Ioanna G

    2009-06-30

    A simple, sensitive and powerful on-line sequential injection (SI) dispersive liquid-liquid microextraction (DLLME) system was developed as an alternative approach for on-line metal preconcentration and separation, using extraction solvent at microlitre volume. The potentials of this novel schema, coupled to flame atomic absorption spectrometry (FAAS), were demonstrated for trace copper and lead determination in water samples. The stream of methanol (disperser solvent) containing 2.0% (v/v) xylene (extraction solvent) and 0.3% (m/v) ammonium diethyldithiophosphate (chelating agent) was merged on-line with the stream of sample (aqueous phase), resulting a cloudy mixture, which was consisted of fine droplets of the extraction solvent dispersed entirely into the aqueous phase. By this continuous process, metal chelating complexes were formed and extracted into the fine droplets of the extraction solvent. The hydrophobic droplets of organic phase were retained into a microcolumn packed with PTFE-turnings. A portion of 300 microL isobutylmethylketone was used for quantitative elution of the analytes, which transported directly to the nebulizer of FAAS. All the critical parameters of the system such as type of extraction solvent, flow-rate of disperser and sample, extraction time as well as the chemical parameters were studied. Under the optimum conditions the enhancement factor for copper and lead was 560 and 265, respectively. For copper, the detection limit and the precision (R.S.D.) were 0.04 microg L(-1) and 2.1% at 2.0 microg L(-1) Cu(II), respectively, while for lead were 0.54 microg L(-1) and 1.9% at 30.0 microg L(-1) Pb(II), respectively. The developed method was evaluated by analyzing certified reference material and applied successfully to the analysis of environmental water samples.

  7. Application of laser ultrasonic method for on-line monitoring of friction stir spot welding process.

    Science.gov (United States)

    Zhang, Kuanshuang; Zhou, Zhenggan; Zhou, Jianghua

    2015-09-01

    Application of a laser ultrasonic method is developed for on-line monitoring of the friction stir spot welding (FSSW) process. Based on the technology of FSSW, laser-generated ultrasonic waves in a good weld and nonweld area are simulated by a finite element method. The reflected and transmitted waves are analyzed to disclose the properties of the welded interface. The noncontact-laser ultrasonic-inspection system was established to verify the numerical results. The reflected waves in the good-weld and nonweld area can be distinguished by time-of-flight. The transmitted waves evidently attenuate in the nonweld area in contrast to signal amplitude in the good weld area because of interfacial impedance difference. Laser ultrasonic C-scan images can sufficiently evaluate the intrinsic character of the weld area in comparison with traditional water-immersion ultrasonic testing results. The research results confirm that laser ultrasonics would be an effective method to realize the characterization of FSSW defects.

  8. Representative process sampling - in practice

    DEFF Research Database (Denmark)

    Esbensen, Kim; Friis-Pedersen, Hans Henrik; Julius, Lars Petersen

    2007-01-01

    /or periodicity; different nugget effects and process variations ranging from less than one lag to full variogram lag). Variogram data analysis leads to a fundamental decomposition into 0-D sampling vs. 1-D process variances, based on the three principal variogram parameters: range, sill and nugget effect......Didactic data sets representing a range of real-world processes are used to illustrate "how to do" representative process sampling and process characterisation. The selected process data lead to diverse variogram expressions with different systematics (no range vs. important ranges; trends and...... presented cases of variography either solved the initial problems or served to understand the reasons and causes behind the specific process structures revealed in the variograms. Process Analytical Technologies (PAT) are not complete without process TOS....

  9. On-line Determination of Zinc in Water and Biological Samples after Its Preconcentration onto Zincon Anchored Polyurethane Foam.

    Science.gov (United States)

    Azeem, Sami M Abdel; Hanafi, Hassan A; El-Shahat, M F

    2015-01-01

    A fast and sensitive on-line procedure for the determination of zinc in water and biological samples was developed. Zinc was preconcentrated in a mini-column packed with polyurethane foam (PUF) chemically modified with zincon via -N=N- bonding. The optimal conditions for preconcentration were pH 8.5 and sample flow rate of 4.0 mL min(-1). Quantitative desorption of Zn(II) was obtained by 0.1 mol L(-1) hydrochloric acid and subsequent spectrophotmetric determination using 4-(2-pyridylazo)-resorcinol at 498 nm. The obtained detection limit was found to be 3.0 ng mL(-1), precision (RSD) was 4.8 and 6.7% at 20 and 110 ng mL(-1), respectively, for 60 s preconcentration time and enrichment factor was 31. The linearity range was from 10 to 120 ng mL(-1) and maximum sample throughput was 20 h(-1). Finally, the method was successfully applied to the determination of zinc in tap water, Nile River water and human urine samples with RSD in the range of 1.1 - 8.3%.

  10. On-line technique for preparingand measuring stable carbon isotopeof total dissolved inorganic carbonin water samples ( d13CTDIC

    Directory of Open Access Journals (Sweden)

    S. Inguaggiato

    2005-06-01

    Full Text Available A fast and completely automated procedure is proposed for the preparation and determination of d13C of total inorganic carbon dissolved in water ( d13CTDIC. This method is based on the acidification of water samples transforming the whole dissolved inorganic carbon species into CO2. Water samples are directly injected by syringe into 5.9 ml vials with screw caps which have a pierciable rubber septum. An Analytical Precision «Carbonate Prep System» was used both to flush pure helium into the vials and to automatically dispense a fixed amount of H3PO4. Full-equilibrium conditions between produced CO2 and water are reached at a temperature of 70°C (± 0.1°C in less than 24 h. Carbon isotope ratios (13C/ 12C were measured on an AP 2003 continuous flow mass spectrometer, connected on-line with the injection system. The precision and reproducibility of the proposed method was tested both on aqueous standard solutions prepared using Na2CO3 with d13C=-10.78 per mil versus PDB (1 s= 0.08, n = 11, and at five different concentrations (2, 3, 4, 5 and 20 mmol/l and on more than thirty natural samples. Mean d13CTDIC on standard solution samples is ?10.89 < per mil versus PDB (1 s= 0.18, n = 50, thus revealing both a good analytical precision and reproducibility. A comparison between average d13CTDIC values on a quadruplicate set of natural samples and those obtained following the chemical and physical stripping method highlights a good agreement between the two analytical methods.

  11. Multivariate detection limits of on-line NIR model for extraction process of chlorogenic acid from Lonicera japonica.

    Science.gov (United States)

    Wu, Zhisheng; Sui, Chenglin; Xu, Bing; Ai, Lu; Ma, Qun; Shi, Xinyuan; Qiao, Yanjiang

    2013-04-15

    A methodology is proposed to estimate the multivariate detection limits (MDL) of on-line near-infrared (NIR) model in Chinese Herbal Medicines (CHM) system. In this paper, Lonicera japonica was used as an example, and its extraction process was monitored by on-line NIR spectroscopy. Spectra of on-line NIR could be collected by two fiber optic probes designed to transmit NIR radiation by a 2mm-flange. High performance liquid chromatography (HPLC) was used as a reference method to determine the content of chlorogenic acid in the extract solution. Multivariate calibration models were carried out including partial least squares regression (PLS) and interval partial least-squares (iPLS). The result showed improvement of model performance: compared with PLS model, the root mean square errors of prediction (RMSEP) of iPLS model decreased from 0.111mg to 0.068mg, and the R(2) parameter increased from 0.9434 to 0.9801. Furthermore, MDL values were determined by a multivariate method using the type of errors and concentration ranges. The MDL of iPLS model was about 14ppm, which confirmed that on-line NIR spectroscopy had the ability to detect trace amounts of chlorogenic acid in L. japonica. As a result, the application of on-line NIR spectroscopy for monitoring extraction process in CHM could be very encouraging and reliable.

  12. On-Line Processing of Tense and Temporality in Agrammatic Aphasia

    Science.gov (United States)

    Faroqi-Shah, Yasmeen; Dickey, Michael Walsh

    2009-01-01

    Agrammatic aphasic individuals exhibit marked production deficits for tense morphology. This paper presents three experiments examining whether a group of English-speaking agrammatic individuals (n = 10) exhibit parallel deficits in their comprehension of tense. Results from two comprehension experiments (on-line grammaticality judgment studies)…

  13. Using an On-Line Tool To Investigate Chemical Engineering Seniors' Concept of the Design Process.

    Science.gov (United States)

    Streveler, Ruth A.; Miller, Ronald L.; Boyd, Thomas M.

    In this study, multidimensional scaling (MDS) was used to measure how 23 chemical engineering seniors categorized key design terms at the beginning and end of a capstone design course. An on-line method was developed to collect the MDS data. The results suggest that some important design concepts were not well understood, even at the end of the…

  14. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    for on-line matrix separation and pre-concentration of trace levels of metals with detection by ICP-MS. It highlights some of the frequently applied on-line, sample-pre-treatment schemes, including solid phase extraction (SPE), on-wall molecular sorption and precipitate/(co)-precipitate retention using...... a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn...

  15. On-line monitoring of food fermentation processes using electronic noses and electronic tongues: a review.

    Science.gov (United States)

    Peris, Miguel; Escuder-Gilabert, Laura

    2013-12-04

    Fermentation processes are often sensitive to even slight changes of conditions that may result in unacceptable end-product quality. Thus, close follow-up of this type of processes is critical for detecting unfavorable deviations as early as possible in order to save downtime, materials and resources. Nevertheless the use of traditional analytical techniques is often hindered by the need for expensive instrumentation and experienced operators and complex sample preparation. In this sense, one of the most promising ways of developing rapid and relatively inexpensive methods for quality control in fermentation processes is the use of chemical multisensor systems. In this work we present an overview of the most important contributions dealing with the monitoring of fermentation processes using electronic noses and electronic tongues. After a brief description of the fundamentals of both types of devices, the different approaches are critically commented, their strengths and weaknesses being highlighted. Finally, future trends in this field are also mentioned in the last section of the article.

  16. Laser mass spectrometry as on-line sensor for industrial process analysis: process control of coffee roasting.

    Science.gov (United States)

    Dorfner, Ralph; Ferge, Thomas; Yeretzian, Chahan; Kettrup, Antonius; Zimmermann, Ralf

    2004-03-01

    The objective of the project is to develop on-line, real-time, and noninvasive process control tools of coffee roasting that help deliver a consistent and high-quality coffee aroma. The coffee roasting process was analyzed by direct injection of the roaster gas into a time-of-flight mass spectrometer and ionized either by resonance enhanced multiphoton ionization (REMPI) at 266 and 248 nm or vacuum ultraviolet single-photon ionization (VUV-SPI) at 118 nm. The VUV ionization scheme allows detecting mainly the most volatile and abundant compounds of molecular mass below 100 m/z, while REMPI ionizes mainly aromatic compounds of molecular mass larger than 100 m/z. Combining the compounds ionized by resonant and single-photon ionization, approximately 30 volatile organic compounds are monitored in real time. Time-intensity profiles of 10 important volatile coffee compounds were discussed in connection with their formation chemistry during roasting. Applying multivariate statistics (principle component analysis) on time-intensity traces of nine volatile coffee compounds, the roasting degree could be traced as a consistent path in the score plot of the two most significant principle components (including 68% of the total variance), for a range of roasting temperatures (200-250 degrees C).

  17. NON-INVASIVE SPECTROSCOPIC ON-LINE METHODS TO MONITOR INDUSTRIAL PROCESSES

    DEFF Research Database (Denmark)

    Brooker, M. H.; Berg, Rolf W.

    2003-01-01

    Vibrational spectroscopy can be used to identify and establish concentrations of many common molecules and complex ions over a wide range of concentrations and conditions. Advances in CCD detection devices, notch-filters, lasers, micro- and fiber-optics have made it possible to use infrared and R......, studied with non-invasive Raman spectroscopy), and finally a discussion of some recent advances in experimental methods that make it possible to use Raman and infrared spectroscopy for on line analyses in some industrial applications.......Vibrational spectroscopy can be used to identify and establish concentrations of many common molecules and complex ions over a wide range of concentrations and conditions. Advances in CCD detection devices, notch-filters, lasers, micro- and fiber-optics have made it possible to use infrared...

  18. FPGA implementation of a hybrid on-line process monitoring in PC based real-time systems

    Directory of Open Access Journals (Sweden)

    Jovanović Bojan

    2011-01-01

    Full Text Available This paper presents one way of FPGA implementation of hybrid (hardware-software based on-line process monitoring in Real-Time systems (RTS. The reasons for RTS monitoring are presented at the beginning. The summary of different RTS monitoring approaches along with its advantages and drawbacks are also exposed. Finally, monitoring module is described in details. Also, FPGA implementation results and some useful monitoring system applications are mentioned.

  19. On-line elemental analysis of fossil fuel process streams by inductively coupled plasma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chisholm, W.P.

    1995-06-01

    METC is continuing development of a real-time, multi-element plasma based spectrometer system for application to high temperature and high pressure fossil fuel process streams. Two versions are under consideration for development. One is an Inductively Coupled Plasma system that has been described previously, and the other is a high power microwave system. The ICP torch operates on a mixture of argon and helium with a conventional annular swirl flow plasma gas, no auxiliary gas, and a conventional sample stream injection through the base of the plasma plume. A new, demountable torch design comprising three ceramic sections allows bolts passing the length of the torch to compress a double O-ring seal. This improves the reliability of the torch. The microwave system will use the same data acquisition and reduction components as the ICP system; only the plasma source itself is different. It will operate with a 750-Watt, 2.45 gigahertz microwave generator. The plasma discharge will be contained within a narrow quartz tube one quarter wavelength from a shorted waveguide termination. The plasma source will be observed via fiber optics and a battery of computer controlled monochromators. To extract more information from the raw spectral data, a neural net computer program is being developed. This program will calculate analyte concentrations from data that includes analyte and interferant spectral emission intensity. Matrix effects and spectral overlaps can be treated more effectively by this method than by conventional spectral analysis.

  20. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Kai-Ta; Liu, Pei-Han [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Urban, Pawel L. [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Institute of Molecular Science, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China)

    2015-09-24

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h{sup −1}). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates

  1. Automated column liquid chromatographic determination of amoxicillin and cefadroxil in bovine serum and muscle tissue using on-line dialysis for sample preparation

    NARCIS (Netherlands)

    Snippe, N; van de Merbel, N C; Ruiter, F P; Steijger, O M; Lingeman, H; Brinkman, U A

    1994-01-01

    A fully automated method is described for the determination of amoxicillin and cefadroxil in bovine serum and muscle tissue. The method is based on the on-line combination of dialysis and solid-phase extraction for sample preparation, and column liquid chromatography with ultraviolet detection. In o

  2. A LC/UV/Vis method for determination of cyanocobalamin in multivitamin dietary supplements with on-line sample clean-up

    Science.gov (United States)

    A HPLC-UV method using a two-column strategy with a switching valve for on-line sample clean-up was developed for the determination of cyanocobalamin (CN-CBL-vitamin B12, in dietary supplements. The method uses two columns, an Agilent Zorbax C8 (150 mm x 4.6 mm, 5 um particle) reversed-phase column...

  3. Combination Method of Principal Component Analysis and Support Vector Machine for On-line Process Monitoring and Fault Diagnosis

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    On-line monitoring and fault diagnosis of chemical process is extremely important for operation safety and product quality. Principal component analysis (PCA) has been widely used in multivariate statistical process monitoring for its ability to reduce processes dimensions. PCA and other statistical techniques, however, have difficulties in differentiating faults correctly in complex chemical process.Support vector machine (SVM) is a novel approach based on statistical learning theory, which has emerged for feature identification and classification. In this paper, an integrated method is applied for process monitoring and fault diagnosis, which combines PCA for fault feature extraction and multiple SVMs for identification of different fault sources. This approach is verified and illustrated on the Tennessee Eastman benchmark process as a case study.Results show that the proposed PCA-SVMs method has good diagnosis capability and overall diagnosis correctness rate.

  4. Microstructure and Mechanical Properties of J55ERW Steel Pipe Processed by On-Line Spray Water Cooling

    Directory of Open Access Journals (Sweden)

    Zejun Chen

    2017-04-01

    Full Text Available An on-line spray water cooling (OSWC process for manufacturing electric resistance welded (ERW steel pipes is presented to enhance their mechanical properties and performances. This technique reduces the processing needed for the ERW pipe and overcomes the weakness of the conventional manufacturing technique. Industrial tests for J55 ERW steel pipe were carried out to validate the effectiveness of the OSWC process. The microstructure and mechanical properties of the J55 ERW steel pipe processed by the OSWC technology were investigated. The optimized OSWC technical parameters are presented based on the mechanical properties and impact the performance of steel pipes. The industrial tests show that the OSWC process can be used to efficiently control the microstructure, enhance mechanical properties, and improve production flexibility of steel pipes. The comprehensive mechanical properties of steel pipes processed by the OSWC are superior to those of other published J55 grade steels.

  5. Markov Decision Process Based Energy-Efficient On-Line Scheduling for Slice-Parallel Video Decoders on Multicore Systems

    CERN Document Server

    Mastronarde, Nicholas; Atienza, David; Frossard, Pascal; van der Schaar, Mihaela

    2011-01-01

    We consider the problem of energy-efficient on-line scheduling for slice-parallel video decoders on multicore systems. We assume that each of the processors are Dynamic Voltage Frequency Scaling (DVFS) enabled such that they can independently trade off performance for power, while taking the video decoding workload into account. In the past, scheduling and DVFS policies in multi-core systems have been formulated heuristically due to the inherent complexity of the on-line multicore scheduling problem. The key contribution of this report is that we rigorously formulate the problem as a Markov decision process (MDP), which simultaneously takes into account the on-line scheduling and per-core DVFS capabilities; the separate power consumption of the processor cores and caches; and the loss tolerant and dynamic nature of the video decoder's traffic. In particular, we model the video traffic using a Direct Acyclic Graph (DAG) to capture the precedence constraints among frames in a Group of Pictures (GOP) structure, ...

  6. On-Line Monitoring of Fermentation Processes by Near Infrared and Fluorescence Spectroscopy

    DEFF Research Database (Denmark)

    Svendsen, Carina

    physical and chemical changes appearing in a lactic fermentation process. The physical changes were associated with the textural transformation appearing during the gel formation and chemical changes were associated with the biological conversion reactions, which take place during the fermentation process...

  7. On-line testing of calibration of process instrumentation channels in nuclear power plants. Phase 2, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hashemian, H.M. [Analysis and Measurement Services Corp., Knoxville, TN (United States)

    1995-11-01

    The nuclear industry is interested in automating the calibration of process instrumentation channels; this report provides key results of one of the sponsored projects to determine the validity of automated calibrations. Conclusion is that the normal outputs of instrument channels in nuclear plants can be monitored over a fuel cycle while the plant is operating to determine calibration drift in the field sensors and associated signal conversion and signal conditioning equipment. The procedure for on-line calibration tests involving calculating the deviation of each instrument channel from the best estimate of the process parameter that the instrument is measuring. Methods were evaluated for determining the best estimate. Deviation of each signal from the best estimate is updated frequently while the plant is operating and plotted vs time for entire fuel cycle, thereby providing time history plots that can reveal channel drift and other anomalies. Any instrument channel that exceeds allowable drift or channel accuracy band is then scheduled for calibration during a refueling outage or sooner. This provides calibration test results at the process operating point, one of the most critical points of the channel operation. This should suffice for most narrow-range instruments, although the calibration of some instruments can be verified at other points throughout their range. It should be pointed out that the calibration of some process signals such as the high pressure coolant injection flow in BWRs, which are normally off- scale during plant operation, can not be tested on-line.

  8. On-line, real-time monitoring for petrochemical and pipeline process control applications

    Energy Technology Data Exchange (ETDEWEB)

    Kane, Russell D.; Eden, D.C.; Cayard, M.S.; Eden, D.A.; Mclean, D.T. [InterCorr International, Inc., 14503 Bammel N. Houston, Suite 300, Houston Texas 77014 (United States); Kintz, J. [BASF Corporation, 602 Copper Rd., Freeport, Texas 77541 (United States)

    2004-07-01

    Corrosion problems in petroleum and petrochemical plants and pipeline may be inherent to the processes, but costly and damaging equipment losses are not. With the continual drive to increase productivity, while protecting both product quality, safety and the environment, corrosion must become a variable that can be continuously monitored and assessed. This millennium has seen the introduction of new 'real-time', online measurement technologies and vast improvements in methods of electronic data handling. The 'replace when it fails' approach is receding into a distant memory; facilities management today is embracing new technology, and rapidly appreciating the value it has to offer. It has offered the capabilities to increase system run time between major inspections, reduce the time and expense associated with turnaround or in-line inspections, and reduce major upsets which cause unplanned shut downs. The end result is the ability to know on a practical basis of how 'hard' facilities can be pushed before excessive corrosion damage will result, so that process engineers can understand the impact of their process control actions and implement true asset management. This paper makes reference to use of a online, real-time electrochemical corrosion monitoring system - SmartCET 1- in a plant running a mostly organic process media. It also highlights other pertinent examples where similar systems have been used to provide useful real-time information to detect system upsets, which would not have been possible otherwise. This monitoring/process control approach has operators and engineers to see, for the first time, changes in corrosion behavior caused by specific variations in process parameters. Process adjustments have been identified that reduce corrosion rates while maintaining acceptable yields and quality. The monitoring system has provided a new window into the chemistry of the process, helping chemical engineers improve their process

  9. On-line method of determining utilization factor in Hg-196 photochemical separation process

    Science.gov (United States)

    Grossman, Mark W.; Moskowitz, Philip E.

    1992-01-01

    The present invention is directed to a method for determining the utilization factor [U] in a photochemical mercury enrichment process (.sup.196 Hg) by measuring relative .sup.196 Hg densities using absorption spectroscopy.

  10. Children’s and Adults’ On-Line Processing of Syntactically Ambiguous Sentences during Reading

    Science.gov (United States)

    Joseph, Holly S. S. L.; Liversedge, Simon P.

    2013-01-01

    While there has been a fair amount of research investigating children’s syntactic processing during spoken language comprehension, and a wealth of research examining adults’ syntactic processing during reading, as yet very little research has focused on syntactic processing during text reading in children. In two experiments, children and adults read sentences containing a temporary syntactic ambiguity while their eye movements were monitored. In Experiment 1, participants read sentences such as, ‘The boy poked the elephant with the long stick/trunk from outside the cage’ in which the attachment of a prepositional phrase was manipulated. In Experiment 2, participants read sentences such as, ‘I think I’ll wear the new skirt I bought tomorrow/yesterday. It’s really nice’ in which the attachment of an adverbial phrase was manipulated. Results showed that adults and children exhibited similar processing preferences, but that children were delayed relative to adults in their detection of initial syntactic misanalysis. It is concluded that children and adults have the same sentence-parsing mechanism in place, but that it operates with a slightly different time course. In addition, the data support the hypothesis that the visual processing system develops at a different rate than the linguistic processing system in children. PMID:23349807

  11. Neural network model for the on-line monitoring of a crystallization process

    Directory of Open Access Journals (Sweden)

    Guardani R.

    2001-01-01

    Full Text Available This paper presents the results of the application of a recently developed technique, based on Neural Networks (NN, in the recognition of angular distribution patterns of light scattered by particles in suspension, for the purpose of estimating concentration and crystal size distribution (CSD in a precipitation process based on the addition of antisolvent (a model system consisting of sodium chloride, water and ethanol. In the first step, in NN model was fitted, using particles with different size distributions and concentrations. Then the model was used to monitor the process, thus enabling a fast and reliable estimation of supersaturation and CSD. Such information, which is difficult to obtain by any other means, can be used in the study of fundamental aspects of crystallization and precipitation processes.

  12. A miniature condensed-phase membrane introduction mass spectrometry (CP-MIMS) probe for direct and on-line measurements of pharmaceuticals and contaminants in small, complex samples.

    Science.gov (United States)

    Duncan, Kyle D; Willis, Megan D; Krogh, Erik T; Gill, Christopher G

    2013-06-15

    High-throughput, automated analytical measurements are desirable in many analytical scenarios, as are rapid sample pre-screening techniques to identify 'positive' samples for subsequent measurements using more time-consuming conventional methodologies (e.g., liquid chromatography/mass spectrometry (LC/MS)). A miniature condensed-phase membrane introduction mass spectrometry (CP-MIMS) probe for the direct and continuous, on-line measurement of pharmaceuticals and environmental contaminants in small, complex samples is presented. A miniature polydimethylsiloxane hollow fibre membrane (PDMS-HFM) probe is coupled with an electrospray ionization (ESI) triple quadrupole mass spectrometer. Analytes are transported from the probe to the ESI source by a methanol acceptor phase. The probe can be autosampler mounted and directly inserted in small samples (≥400 μL) allowing continuous and simultaneous pptr-ppb level detection of target analytes (chlorophenols, triclosan, gemfibrozil, nonylphenol) in complex samples (artificial urine, beer, natural water, waste water, plant tissue). The probe has been characterized and optimized for acceptor phase flow rate, sample mixing and probe washing. Signal response times, detection limits and calibration data are given for selected ion monitoring (SIM) and tandem mass spectrometry (MS/MS) measurements of target analytes at trace levels. Comparisons with flow cell type CP-MIMS systems are given. Analyte depletion effects are evaluated for small samples (≥400 μL). On-line measurements in small volumes of complex samples, temporally resolved reaction monitoring and in situ/in vivo demonstrations are presented. The miniature CP-MIMS probe developed was successfully used for the direct, on-line detection of target analytes in small volumes (40 mL to 400 μL) of complex samples at pptr to low ppb levels. The probe can be readily automated as well as deployed for in situ/in vivo monitoring, including reaction monitoring, small sample

  13. Young children with ASD use lexical and referential information during on-line sentence processing

    Directory of Open Access Journals (Sweden)

    Edith L. Bavin

    2016-02-01

    Full Text Available Research with adults and older children indicates that verb biases are strong influences on listeners’ interpretations when processing sentences, but they can be overruled. In this paper we ask two questions: (i are children with ASD who are high functioning sensitive to verb biases like their same age typically developing peers?, and (ii do young children with ASD and young children with typical development override strong verb biases to consider alternative interpretations of ambiguous sentences? Participants were aged 5-9 years (mean age 6.65 years: children with ASD who were high functioning and children with typical development. In task 1 biasing and neutral verbs were included (e.g., eat cake versus move cake. In task 2 the focus was on whether the prepositional phrase occurring with an instrument biasing verb (e.g. ‘chop the tree with the axe’ was interpreted as an instrument even if the named item was an implausible instrument (e.g. candle in ‘Cut the cake with the candle’. Overall, the results showed similarities between groups but the ASD group was generally slower. In task 1, both groups looked at the named object faster in the biasing than the non-biasing condition, and in the biasing condition the ASD group looked away from the target more quickly than the TD group. In task 2, both groups identified the target in the prepositional phrase. They were more likely to override the verb instrument bias and consider the alternative (modification interpretation in the implausible condition (e.g., looking at the picture of a cake with a candle on it’. Our findings indicate that children of age 5 years and above can use context to override verb biases. Additionally, an important component of the sentence processing mechanism is largely intact for young children with ASD who are high functioning. Like children with typical development, they draw on verb semantics and plausibility in integrating information. However, they are likely

  14. Study on on-line processing of the chaos laser radar using FPGA

    OpenAIRE

    2005-01-01

    Today, a car industry puts effort into making intelligent car to realize a safe and comfortable car society. As one of the sensing technology, laser radar is widely studied as in-car radar. The received signal in the laser radar becomes to be buried in noise with increasing distance. When the long distance is measured, it needs a high power laser, or the repetitive process that uses multiplication and integration. Therefore, a new type of the chaos laser radar has been studied. This laser rad...

  15. On-line SPE sample treatment as a tool for method automatization and detection limits reduction: Quantification of 25-hydroxyvitamin D3/D2.

    Science.gov (United States)

    Palaiogiannis, Dimitrios; Bekou, Evangelia; Pazaitou-Panayiotou, Kalliopi; Samanidou, Victoria; Tsakalof, Andreas

    2017-02-01

    The development and approbation of new, automated UHPLC-DAD method for the quantification of 25-hydroxyvitamin D3/D2 (25OH-D3/D2) metabolites in plasma/serum for the evaluation of patient's vitamin D status are presented. The method was developed on the Ultimate 3000 UHPLC dual gradient system supplied with the on-line SPE-concentration column coupled through six port switching valve to analytical column. This configuration and materials selected enable large volume sample injection (500μL) and on-line sample preconcentration, clean up and subsequent selective metabolites transfer onto the analytical column. The new method abrogates main conventional time consuming and error source off-line steps of analysis and thus simplifies analysis. The large volume injection increases the sensitivity of instrumental analysis by about ten-fold on-line pre-concentration of metabolites. The instrument response is linear (R>0.99) in the investigated concentration range 10-100ngmL(-1) which covers all the possible vitamin D status from serious deficiency (D3)=0.94ngmL(-1) and LOD (25OH-D2)=2.4ngmL(-1). The method performance was assessed with the use of certified reference samples and perfect agreement between certified and measured values is demonstrated. The method was applied to human samples previously analyzed for total vitamin D by Competitive Protein-binding assay and findings of the two methods are compared.

  16. Continuous Flow Liquid Microjunction Surface Sampling Probe Connected On-line with HPLC/MS for Spatially Resolved Analysis of Small Molecules and Proteins

    Energy Technology Data Exchange (ETDEWEB)

    Van Berkel, Gary J [ORNL; Kertesz, Vilmos [ORNL

    2013-01-01

    RATIONALE: A continuous flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by MS. Demonstrated here is the on-line coupling of such a probe with HPLC/MS enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. Methods: A continuous flow liquid microjunction surface sampling probe was connected to a 6-port, 2-position valve for extract collection and injection to an HPLC column. A QTRAP 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V ion source operated in positive ESI mode was used for all experiments. System operation was tested with extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues and proteins from dried sheep blood spots on paper. Results: Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s extractions). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin and chains. Conclusions: Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection.

  17. On-Line GIS Analysis and Image Processing for Geoportal Kielce/poland Development

    Science.gov (United States)

    Hejmanowska, B.; Głowienka, E.; Florek-Paszkowski, R.

    2016-06-01

    GIS databases are widely available on the Internet, but mainly for visualization with limited functionality; very simple queries are possible i.e. attribute query, coordinate readout, line and area measurements or pathfinder. A little more complex analysis (i.e. buffering or intersection) are rare offered. Paper aims at the concept of Geoportal functionality development in the field of GIS analysis. Multi-Criteria Evaluation (MCE) is planned to be implemented in web application. OGC Service is used for data acquisition from the server and results visualization. Advanced GIS analysis is planned in PostGIS and Python programming. In the paper an example of MCE analysis basing on Geoportal Kielce is presented. Other field where Geoportal can be developed is implementation of processing new available satellite images free of charge (Sentinel-2, Landsat 8, ASTER, WV-2). Now we are witnessing a revolution in access to the satellite imagery without charge. This should result in an increase of interest in the use of these data in various fields by a larger number of users, not necessarily specialists in remote sensing. Therefore, it seems reasonable to expand the functionality of Internet's tools for data processing by non-specialists, by automating data collection and prepared predefined analysis.

  18. On-line process analysis innovation: DiComp (tm) shunting dielectric sensor technology

    Science.gov (United States)

    Davis, Craig R.; Waldman, Frank A.

    1993-01-01

    The DiComp Shunting Dielectric Sensor (SDS) is a new patent-pending technology developed under the Small Business Innovation Research Program (SBIR) for NASA's Kennedy Space Center. The incorporation of a shunt electrode into a conventional fringing field dielectric sensor makes the SDS uniquely sensitive to changes in material dielectric properties in the KHz to MHz range which were previously detectable only at GHz measurement frequencies. The initial NASA application of the SDS for Nutrient Delivery Control has demonstrated SDS capabilities for thickness and concentration measurement of Hoagland nutrient solutions. The commercial introduction of DiComp SDS technology for concentration and percent solids measurements in dispersions, emulsions and solutions represents a new technology for process measurements for liquids in a variety of industries.

  19. Polymer monolithic capillary microextraction on-line coupled with inductively coupled plasma-mass spectrometry for the determination of trace Au and Pd in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaolan; He, Man; Chen, Beibei; Hu, Bin, E-mail: binhu@whu.edu.cn

    2014-11-01

    A novel method based on on-line polymer monolithic capillary microextraction (CME)-inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Au and Pd in biological samples. For this purpose, poly(glycidyl methacrylate-ethylene dimethacrylate) monolith was prepared and functionalized with mercapto groups. The prepared monolith exhibited good selectivity to Au and Pd, and good resistance to strong acid with a long life span. Factors affecting the extraction efficiency of CME, such as sample acidity, sample flow rate, eluent conditions and coexisting ion interference were investigated in detail. Under the optimal conditions, the limits of detection (LODs, 3σ) were 5.9 ng L{sup −1} for Au and 8.3 ng L{sup −1} for Pd, and the relative standard deviations (RSDs, c = 50 ng L{sup −1}, n = 7) were 6.5% for Au and 1.1% for Pd, respectively. The developed method was successfully applied to the determination of Au and Pd in human urine and serum samples with the recovery in the range of 84–118% for spiked samples. The developed on-line polymer monolithic CME-ICP-MS method has the advantages of rapidity, simplicity, low sample/reagent consumption, high sensitivity and is suitable for the determination of trace Au and Pd in biological samples with limited amount available and complex matrix. - Highlights: • An on-line CME-ICP-MS method was developed for Au and Pd analysis in human fluids. • Poly(GMA-EDMA-SH) monolith exhibited good selectivity for Au/Pd and acid-resistance. • The method is rapid, simple, and sensitive with low sample/reagents consumption.

  20. On-line surveillance of a dynamic process by a moving system based on pulsed digital holographic interferometry.

    Science.gov (United States)

    Pedrini, Giancarlo; Alexeenko, Igor; Osten, Wolfgang; Schnars, Ulf

    2006-02-10

    A method based on pulsed digital holographic interferometry for the measurement of dynamic deformations of a surface by using a moving system is presented. The measuring system may move with a speed of several meters per minute and can measure deformation of the surface with an accuracy of better than 50 nm. The deformation is obtained by comparison of the wavefronts recorded at different times with different laser pulses produced by a Nd:YAG laser. The effect due to the movement of the measuring system is compensated for by digital processing of the different holograms. The system is well suited for on-line surveillance of a dynamic process such as laser welding and friction stir welding. Experimental results are presented, and the advantages of the method are discussed.

  1. Application of a Mechanistic Model as a Tool for On-line Monitoring of Pilot Scale Filamentous Fungal Fermentation Processes - The Importance of Evaporation Effects

    DEFF Research Database (Denmark)

    Mears, Lisa; Stocks, Stuart M.; Albæk, Mads Orla

    2017-01-01

    block models the changing rates of formation of product, biomass, and water, and the rate of consumption of feed using standard, available on-line measurements. This parameter estimation block, is coupled to a mechanistic process model, which solves the current states of biomass, product, substrate...... a historical dataset of eleven batches from the fermentation pilot plant (550L) at Novozymes A/S. The model is then implemented on-line in 550L fermentation processes operated at Novozymes A/S in order to validate the state estimator model on fourteen new batches utilizing a new strain. The product...... of the input data. Parameter estimation uncertainty is also carried out. The application of this on-line state estimator allows for on-line monitoring of pilot scale batches, including real-time estimates of multiple parameters which are not able to be monitored on-line. With successful application of a soft...

  2. Monitoring of an esterification reaction by on-line direct liquid sampling mass spectrometry and in-line mid infrared spectrometry with an attenuated total reflectance probe

    Energy Technology Data Exchange (ETDEWEB)

    Owen, Andrew W.; McAulay, Edith A.J. [WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL (United Kingdom); Nordon, Alison, E-mail: alison.nordon@strath.ac.uk [WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL (United Kingdom); Littlejohn, David, E-mail: d.littlejohn@strath.ac.uk [WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL (United Kingdom); Lynch, Thomas P. [WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL (United Kingdom); Lancaster, J. Steven [Hull Research and Technology Centre, BP Chemicals, Hull, HU12 8DS (United Kingdom); Wright, Robert G. [Thermo Fisher Scientific, Winsford, Cheshire, CW7 3GA (United Kingdom)

    2014-11-07

    Highlights: • High efficiency thermal vaporiser designed and used for on-line reaction monitoring. • Concentration profiles of all reactants and products obtained from mass spectra. • By-product formed from the presence of an impurity detected by MS but not MIR. • Mass spectrometry can detect trace and bulk components unlike molecular spectrometry. - Abstract: A specially designed thermal vaporiser was used with a process mass spectrometer designed for gas analysis to monitor the esterification of butan-1-ol and acetic anhydride. The reaction was conducted at two scales: in a 150 mL flask and a 1 L jacketed batch reactor, with liquid delivery flow rates to the vaporiser of 0.1 and 1.0 mL min{sup −1}, respectively. Mass spectrometry measurements were made at selected ion masses, and classical least squares multivariate linear regression was used to produce concentration profiles for the reactants, products and catalyst. The extent of reaction was obtained from the butyl acetate profile and found to be 83% and 76% at 40 °C and 20 °C, respectively, at the 1 L scale. Reactions in the 1 L reactor were also monitored by in-line mid-infrared (MIR) spectrometry; off-line gas chromatography (GC) was used as a reference technique when building partial least squares (PLS) multivariate calibration models for prediction of butyl acetate concentrations from the MIR spectra. In validation experiments, good agreement was achieved between the concentration of butyl acetate obtained from in-line MIR spectra and off-line GC. In the initial few minutes of the reaction the profiles for butyl acetate derived from on-line direct liquid sampling mass spectrometry (DLSMS) differed from those of in-line MIR spectrometry owing to the 2 min transfer time between the reactor and mass spectrometer. As the reaction proceeded, however, the difference between the concentration profiles became less noticeable. DLSMS had advantages over in-line MIR spectrometry as it was easier to

  3. Automatic On-line Solid-phase Extraction-Electrothermal Atomic Absorption Spectrometry Exploiting Sequential Injection Analysis for Trace Vanadium, Cadmium and Lead Determination in Human Urine Samples.

    Science.gov (United States)

    Giakisikli, Georgia; Ayala Quezada, Alejandro; Tanaka, Junpei; Anthemidis, Aristidis N; Murakami, Hiroya; Teshima, Norio; Sakai, Tadao

    2015-01-01

    A fully automated sequential injection column preconcentration method for the on-line determination of trace vanadium, cadmium and lead in urine samples was successfully developed, utilizing electrothermal atomic absorption spectrometry (ETAAS). Polyamino-polycarboxylic acid chelating resin (Nobias chelate PA-1) packed into a handmade minicolumn was used as a sorbent material. Effective on-line retention of chelate complexes of analytes was achieved at pH 6.0, while the highest elution effectiveness was observed with 1.0 mol L(-1) HNO3 in the reverse phase. Several analytical parameters, like the sample acidity, concentration and volume of the eluent as well as the loading/elution flow rates, have been studied, regarding the efficiency of the method, providing appropriate conditions for the analysis of real samples. For a 4.5 mL sample volume, the sampling frequency was 27 h(-1). The detection limits were found to be 3.0, 0.06 and 2.0 ng L(-1) for V(V), Cd(II) and Pb(II), respectively, with the relative standard deviations ranging between 1.9 - 3.7%. The accuracy of the proposed method was evaluated by analyzing a certified reference material (Seronorm(TM) trace elements urine) and spiked urine samples.

  4. Fast response filter module with plug flow of filtrate for on-line sampling from submerged cultures of filamentous fungi

    NARCIS (Netherlands)

    Poulsen, B.R.; Ruijter, G.J.G.; Panneman, H.; Iversen, J.J.L.; Visser, J.

    2004-01-01

    Automatic and accurate sampling is both convenient and sometimes necessary to obtain detailed information about cell cultures. We developed an autoclavable sampling system in which culture broth was pumped through an ultrafiltration cross-flow module with a novel filtrate collecting principle and a

  5. On-line application of near-infrared spectroscopy for monitoring water levels in parts per million in a manufacturing-scale distillation process.

    Science.gov (United States)

    Lambertus, Gordon; Shi, Zhenqi; Forbes, Robert; Kramer, Timothy T; Doherty, Steven; Hermiller, James; Scully, Norma; Wong, Sze Wing; LaPack, Mark

    2014-01-01

    An on-line analytical method based on transmission near-infrared spectroscopy (NIRS) for the quantitative determination of water concentrations (in parts per million) was developed and applied to the manufacture of a pharmaceutical intermediate. Calibration models for water analysis, built at the development site and applied at the manufacturing site, were successfully demonstrated during six manufacturing runs at a 250-gallon scale. The water measurements will be used as a forward-processing control point following distillation of a toluene product solution prior to use in a Grignard reaction. The most significant impact of using this NIRS-based process analytical technology (PAT) to replace off-line measurements is the significant reduction in the risk of operator exposure through the elimination of sampling of a severely lachrymatory and mutagenic compound. The work described in this report illustrates the development effort from proof-of-concept phase to manufacturing implementation.

  6. On-line near infrared spectroscopy as a Process Analytical Technology (PAT) tool to control an industrial seeded API crystallization.

    Science.gov (United States)

    Schaefer, C; Lecomte, C; Clicq, D; Merschaert, A; Norrant, E; Fotiadu, F

    2013-09-01

    The final step of an active pharmaceutical ingredient (API) manufacturing synthesis process consists of a crystallization during which the API and residual solvent contents have to be quantified precisely in order to reach a predefined seeding point. A feasibility study was conducted to demonstrate the suitability of on-line NIR spectroscopy to control this step in line with new version of the European Medicines Agency (EMA) guideline [1]. A quantitative method was developed at laboratory scale using statistical design of experiments (DOE) and multivariate data analysis such as principal component analysis (PCA) and partial least squares (PLS) regression. NIR models were built to quantify the API in the range of 9-12% (w/w) and to quantify the residual methanol in the range of 0-3% (w/w). To improve the predictive ability of the models, the development procedure encompassed: outliers elimination, optimum model rank definition, spectral range and spectral pre-treatment selection. Conventional criteria such as, number of PLS factors, R(2), root mean square errors of calibration, cross-validation and prediction (RMSEC, RMSECV, RMSEP) enabled the selection of three model candidates. These models were tested in the industrial pilot plant during three technical campaigns. Results of the most suitable models were evaluated against to the chromatographic reference methods. Maximum relative bias of 2.88% was obtained about API target content. Absolute bias of 0.01 and 0.02% (w/w) respectively were achieved at methanol content levels of 0.10 and 0.13% (w/w). The repeatability was assessed as sufficient for the on-line monitoring of the 2 analytes. The present feasibility study confirmed the possibility to use on-line NIR spectroscopy as a PAT tool to monitor in real-time both the API and the residual methanol contents, in order to control the seeding of an API crystallization at industrial scale. Furthermore, the successful scale-up of the method proved its capability to be

  7. Heat Transfer Modeling of an Annular On-Line Spray Water Cooling Process for Electric-Resistance-Welded Steel Pipe.

    Science.gov (United States)

    Chen, Zejun; Han, Huiquan; Ren, Wei; Huang, Guangjie

    2015-01-01

    On-line spray water cooling (OSWC) of electric-resistance-welded (ERW) steel pipes can replace the conventional off-line heat treatment process and become an important and critical procedure. The OSWC process improves production efficiency, decreases costs, and enhances the mechanical properties of ERW steel pipe, especially the impact properties of the weld joint. In this paper, an annular OSWC process is investigated based on an experimental simulation platform that can obtain precise real-time measurements of the temperature of the pipe, the water pressure and flux, etc. The effects of the modes of annular spray water cooling and related cooling parameters on the mechanical properties of the pipe are investigated. The temperature evolutions of the inner and outer walls of the pipe are measured during the spray water cooling process, and the uniformity of mechanical properties along the circumferential and longitudinal directions is investigated. A heat transfer coefficient model of spray water cooling is developed based on measured temperature data in conjunction with simulation using the finite element method. Industrial tests prove the validity of the heat transfer model of a steel pipe undergoing spray water cooling. The research results can provide a basis for the industrial application of the OSWC process in the production of ERW steel pipes.

  8. Heat Transfer Modeling of an Annular On-Line Spray Water Cooling Process for Electric-Resistance-Welded Steel Pipe

    Science.gov (United States)

    Chen, Zejun; Han, Huiquan; Ren, Wei; Huang, Guangjie

    2015-01-01

    On-line spray water cooling (OSWC) of electric-resistance-welded (ERW) steel pipes can replace the conventional off-line heat treatment process and become an important and critical procedure. The OSWC process improves production efficiency, decreases costs, and enhances the mechanical properties of ERW steel pipe, especially the impact properties of the weld joint. In this paper, an annular OSWC process is investigated based on an experimental simulation platform that can obtain precise real-time measurements of the temperature of the pipe, the water pressure and flux, etc. The effects of the modes of annular spray water cooling and related cooling parameters on the mechanical properties of the pipe are investigated. The temperature evolutions of the inner and outer walls of the pipe are measured during the spray water cooling process, and the uniformity of mechanical properties along the circumferential and longitudinal directions is investigated. A heat transfer coefficient model of spray water cooling is developed based on measured temperature data in conjunction with simulation using the finite element method. Industrial tests prove the validity of the heat transfer model of a steel pipe undergoing spray water cooling. The research results can provide a basis for the industrial application of the OSWC process in the production of ERW steel pipes. PMID:26201073

  9. On-line sensor monitoring for chemical contaminant attenuation during UV/H2O2 advanced oxidation process.

    Science.gov (United States)

    Yu, Hye-Weon; Anumol, Tarun; Park, Minkyu; Pepper, Ian; Scheideler, Jens; Snyder, Shane A

    2015-09-15

    A combination of surrogate parameters and indicator compounds were measured to predict the removal efficiency of trace organic compounds (TOrCs) using low pressure (LP)-UV/H2O2 advanced oxidation process (AOP), engaged with online sensor-based monitoring system. Thirty-nine TOrCs were evaluated in two distinct secondary wastewater effluents in terms of estimated photochemical reactivity, as a function of the rate constants of UV direct photolysis (kUV) and hydroxyl radical (OH) oxidation (kOH). The selected eighteen TOrCs were classified into three groups that served as indicator compounds: Group 1 for photo-susceptible TOrCs but with minor degradation by OH oxidation (diclofenac, fluoxetine, iohexol, iopamidol, iopromide, simazine and sulfamethoxazole); Group 2 for TOrCs susceptible to both direct photolysis and OH oxidation (benzotriazole, diphenhydramine, ibuprofen, naproxen and sucralose); and Group 3 for photo-resistant TOrCs showing dominant degradation by OH oxidation (atenolol, carbamazepine, DEET, gemfibrozil, primidone and trimethoprim). The results indicate that TOC (optical-based measurement), UVA254 or UVT254 (UV absorbance or transmittance at 254 nm), and total fluorescence can all be used as suitable on-line organic surrogate parameters to predict the attenuation of TOrCs. Furthermore, the automated real-time monitoring via on-line surrogate sensors and equipped with the developed degradation profiles between sensor response and a group of TOrCs removal can provide a diagnostic tool for process control during advanced treatment of reclaimed waters.

  10. On Processing Hexagonally Sampled Images

    Science.gov (United States)

    2011-07-01

    Definition Addition Negation Subtraction Scalar Multiplication                  2121 2121 21 2 aacc aarr aa pp1...coordinate system for addressing a hexagonal grid that provides support for efficient image processing • Efficient ASA methods were shown for gradient

  11. Fast determination of the relative elemental and organic carbon content of aerosol samples by on-line single-particle aerosol time-of-flight mass spectrometry.

    Science.gov (United States)

    Ferge, T; Karg, E; Schröppel, A; Coffee, K R; Tobias, H J; Frank, M; Gard, E E; Zimmermann, R

    2006-05-15

    Different particulate matter (PM) samples were investigated by on-line single-particle aerosol time-of-flight mass spectrometry (ATOFMS). The samples consist of soot particulates made by a diffusion flame soot generator (combustion aerosol standard, CAST), industrially produced soot material (printex), soot from a diesel passenger car as well as ambient particulates (urban dust (NIST) and road tunnel dust). Five different CAST soot particle samples were generated with different elemental carbon (EC) and organic carbon (OC) content. The samples were reaerosolized and on-line analyzed by ATOFMS, as well as precipitated on quartz filters for conventional EC/OC analysis. For each sample ca. 1000 ATOFMS single-particle mass spectra were recorded and averaged. A typical averaged soot ATOFMS mass spectrum shows characteristic carbon cluster peak progressions (Cn+) as well as hydrogen-poor carbon cluster peaks (CnH(1-3)+). These peaks are originated predominately from the elemental carbon (EC) content of the particles. Often additional peaks, which are not due to carbon clusters, are observed, which either are originated from organic compounds (OC-organic carbon), or from the non-carbonaceous inorganic content of the particles. By classification of the mass spectral peaks as elemental carbon (i.e., the carbon cluster progression peaks) or as peaks originated from organic compounds (i.e., molecular and fragment ions), the relative abundance of elemental (EC) and organic carbon (OC) can be determined. The dimensionless TC/EC values, i.e., the ratio of total carbon content (TC, TC = OC + EC) to elemental carbon (EC), were derived from the ATOFMS single-particle aerosol mass spectrometry data. The EC/TC values measured by ATOFMS were compared with the TC/EC values determined by the thermal standard techniques (thermooptical and thermocoulometric method). A good agreement between the EC/TC values obtained by on-line ATOFMS and the offline standard method was found.

  12. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  13. [Determination of trace and ultra-trace level bromate in water by large volume sample injection with enrichment column for on-line preconcentration coupled with ion chromatography].

    Science.gov (United States)

    Liu, Jing; He, Qingqing; Yang, Lili; Hu, Enyu; Wang, Meifei

    2015-10-01

    A method for the determination of trace and ultra-trace level bromate in water by ion chromatography with large volume sample injection for on-line preconcentration was established. A high capacity Dionex IonPac AG23 guard column was simply used as the enrichment column instead of the loop for the preconcentration of bromate. High purity KOH solution used as eluent for gradient elution was on-line produced by an eluent generator automatically. The results showed that a good linear relationship of bromate was exhibited in the range of 0.05-51.2 μg/L (r ≥ 0.999 5), and the method detection limit was 0.01 μg/L. Compared with conventional sample injection, the injection volume was up to 5 mL, and the enrichment factor of this method was about 240 times. This method was successfully applied for several real samples of pure water which were purchased in the supermarket, and the recoveries of bromate were between 90%-100% with the RSDs (n = 6) of 2.1%-6.4% at two spiked levels. This method without pretreatment is simple, and of high accuracy and precision. The preconcentration can be achieved by large volume sample injection. It is suitable for the analysis of trace and ultra-trace level bromate.

  14. Generic on-line solid phase extraction sample preparation strategies for the analysis of drugs in biological matrices by LC-MS/MS.

    Science.gov (United States)

    Bourgogne, Emmanuel; Grivet, Chantal; Varesio, Emmanuel; Hopfgartner, Gérard

    2015-01-01

    In the present work we investigate the integration of a single hardware platform (Prospekt-2) allowing on-line SPE with pre-/post-trapping dilution and direct injection of plasma extracts, and also compare the benefits and challenges of the different approaches for pharmaceutical drugs with heterogeneous physicochemical properties. In the first part, the generic use of on-line SPE with direct plasma injection or after protein precipitation was investigated for the quantitative analysis of talinolol. In the second part, pre-trapping and post-trapping dilution for on-line SPE is discussed for generic method development on an oxadiazole and its major metabolite. Finally, the difference of performance between direct plasma injection vs. off-line liquid-liquid extraction is also described for the quantification of buprenorphine and naltrexone down to 50 and 100 pg/ml using a 0.25 ml plasma aliquot. All assays were in human plasma and detection was performed by mass spectrometry detection either on simple or triple stage quadrupoles. Regardless of the tested strategy, assays were found linear, with precision and accuracy with <15% for all quality controls samples and <20% for lower limit of quantitation.

  15. Automatized flow-batch method for fluorescent determination of free glycerol in biodiesel samples using on-line extraction.

    Science.gov (United States)

    Lima, Marcelo B; Insausti, Matías; Domini, Claudia E; Pistonesi, Marcelo F; de Araújo, Mário C Ugulino; Band, Beatriz S Fernández

    2012-01-30

    An automatic method, based on flow-batch (FB), for determining glycerol in biodiesel was developed. The FB systems draw upon the useful features of flow, batch and multi-commutation approaches. The standards and samples preparation, as well as, derivatization and analysis were fully automated. For that purpose, a homemade chamber was built. The proposed method is based on liquid-liquid extraction of glycerol and simultaneous oxidation with periodate, generating formaldehyde that reacts with acetylacetone. A fluorescent product of 3,5-diacetyl-1,4-dihydrolutidine was obtained. The fluorescence signal was recorded at λ(ex) =417 nm and λ(em) = 514 nm. A linear response was observed from 0.10 to 5.00 mg L(-1) glycerol, variation coefficient 1.5%, sampling rate 14 h(-1) and detection limit 0.036 mg L(-1) glycerol. The procedure was successfully applied to the analysis of biodiesel samples, and the results agreed with the reference method (ASTM D6584-07) at 95% confidence level. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Measurement of viscosity and shear wave velocity of a liquid or slurry for on-line process control.

    Science.gov (United States)

    Greenwood, Margaret Stautberg; Bamberger, Judith Ann

    2002-08-01

    An on-line sensor to measure the density of a liquid or slurry, based on longitudinal wave reflection at the solid-fluid interface, has been developed by the staff at Pacific Northwest National Laboratory. The objective of this research is to employ shear wave reflection at the solid-fluid interface to provide an on-line measurement of viscosity as well. Both measurements are of great interest for process control in many industries. Shear wave reflection measurements were conducted for a variety of liquids. By analyzing multiple reflections within the solid (only 0.63 cm thick-similar to pipe wall thickness) we increased the sensitivity of the measurement. At the sixth echo, sensitivity was increased sufficiently and this echo was used for fluid interrogation. Shear wave propagation of ultrasound in liquids is dependent upon the viscosity and the shear modulus. The data are analyzed using the theory for light liquids (such as water and sugar water solutions) and also using the theory for highly viscous liquids (such as silicone oils). The results show that, for light liquids, the shear wave reflection measurements interrogate the viscosity. However, for highly viscous liquids, it is the shear wave modulus that dominates the shear wave reflection. Since the density is known, the shear wave velocity in the liquid can be determined from the shear wave modulus. The results show that shear wave velocities in silicone oils are very small and range from 315 to 2389 cm/s. Shear wave reflection measurements are perhaps the only way that shear wave velocity in liquids can be determined, because the shear waves in liquids are highly attenuated. These results show that, depending on the fluid characteristics, either the viscosity or the shear wave velocity can be used for process control. There are several novel features of this sensor: (1) The sensor can be mounted as part of the wall of a pipeline or tank or submerged in a tank. (2) The sensor is very compact and can be

  17. Gender stereotypes across the ages: On-line processing in school-age children, young and older adults.

    Science.gov (United States)

    Siyanova-Chanturia, Anna; Warren, Paul; Pesciarelli, Francesca; Cacciari, Cristina

    2015-01-01

    Most research to date on implicit gender stereotyping has been conducted with one age group - young adults. The mechanisms that underlie the on-line processing of stereotypical information in other age groups have received very little attention. This is the first study to investigate real time processing of gender stereotypes at different age levels. We investigated the activation of gender stereotypes in Italian in four groups of participants: third- and fifth-graders, young and older adults. Participants heard a noun that was stereotypically associated with masculine (preside "headmaster") or feminine roles (badante "social care worker"), followed by a male (padre "father") or female kinship term (madre "mother"). The task was to decide if the two words - the role noun and the kinship term - could describe the same person. Across all age groups, participants were significantly faster to respond, and significantly more likely to press 'yes,' when the gender of the target was congruent with the stereotypical gender use of the preceding prime. These findings suggest that information about the stereotypical gender associated with a role noun is incorporated into the mental representation of this word and is activated as soon as the word is heard. In addition, our results show differences between male and female participants of the various age groups, and between male- and female-oriented stereotypes, pointing to important gender asymmetries.

  18. On-line parallel reversed phase two-dimensional liquid chromatography for high-throughput analysis of complex proteomic samples

    Institute of Scientific and Technical Information of China (English)

    WANG Zhicong; ZHANG Qinghe; LI Tong; ZHAO Zhongyi; ZHANG Weibing

    2006-01-01

    A comprehensive two-dimensional liquid chromatographic system (2D SCX/RP) is constructed with a 10-port-2-way valve using strong cation exchange chromatography (Hypersil SCX, 100 mm×4.6 mm I.D.) followed by reversed phase chromatography (Hypersil BDS C18, 15 mm×4.6 mm I.D.) to separate the complex peptides from globin peptic hydrolysate. After the sample was loaded on the SCX column, the phosphate buffer (pH 4.0) was used to elute the peptides. Then, elutes flowed through the interface and the peptides focused on the head of the trapping columns (Hypersil BDS C18, 15 mm×4.6 mm I.D.) but salt passed into the waste. After the valve was switched, the samples were flushed with a backward flow into the RP analytical column. The peptides on the SCX were eluted with 12 discontinuous steps linearly increasing salt concentrations. The peptides enriched on the trapping column were desalted and separated by the RP columns. The resolution and the resolved peaks of the 2D SCX/RP system were greatly increased and the total peak capacity reached as high as 2280.

  19. Investigations of on-line process analysis in batchwise and continuous ethanol production using Zymomonas mobilis. Untersuchungen zur on-line Prozessanalyse bei der satzweisen und kontinuierlichen Ethanolproduktion mit Zymomonas mobilis

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, W.

    1985-01-01

    A fermentation unit was connected to a process computer for on-line data acquisition, process observation and SPC control. The continuous measurement of relevant process parameters was to enable off-line modelling of growth and product formation of the bacterium Zymomonas mobilis. A continuous analysis of substrate and product concentrations beyond the conventional instrumentation of bioreactors was made possible by using membrane separation processes with subsequent detection of components. A glucose detection method adaptable to glucose was developed. Exhaust gas, dissolved gas and volatile components were measured using a mass spectrometer convected to the reactor. Data acquisition, data analysis and system control were carried out using the process computer system CASFA (= Computer Automation System for Fermentation Systems on the Laboratory Scale).

  20. Application of multiwall carbon nanotubes impregnated with 5-dodecylsalicylaldoxime for on-line copper preconcentration and determination in water samples by flame atomic absorption spectrometry.

    Science.gov (United States)

    Tobiasz, Anna; Walas, Stanisław; Soto Hernández, Arlene; Mrowiec, Halina

    2012-07-15

    The paper presents application of multiwall carbon nanotubes (MWCNTs) modified with 5-dodecylsalicylaldoxime to copper(II) flow-injection on-line preconcentration and flame atomic absorption spectrometric (FAAS) determination. Two new sorbents were obtained by impregnation of MWCNTs with Cu(II)-LIX 622(®) complex, however in the first case modification was preceded by carbon wall activation via oxidization (Cu-LIX-CNT-A sorbent), and in the second one no surface activation was performed (Cu-LIX-CNT sorbent). It was found that effective leaching of initially introduced copper and Cu(II) retained in preconcentration process could be realized with the use 7% and 5% (v/v) nitric acid, for particular sorbents. Testing the influence of loading solution pH and rate of loading on sorption it was found out that optimal range of loading solution pH was about 4.5-6.3 for activated and 6.15-6.25 for non-activated CNT. Investigation of sorption kinetics showed that the process can be described by pseudo-second order reaction model. Sorption equilibrium conditions (90% sorption) for LIX-CNT-A and LIX-CNT were obtained after 8-15min, respectively and maximum sorption capacity for the new sorbents amounted to 18.1mgg(-1) and 31.6mgg(-1), respectively. For the examined sorbents enrichment factors increased with extension of loading time up to 180s: linearly for activated and non-linearly for non-activated MWCNTs. Influence of potential interferents such as Cd(II), Zn(II), Fe(III), Mg(II) and Ca(II) ions on copper(II) sorption on the new CNT materials was examined individually and with the use of 2(5-2) factorial design. The study revealed significant interference from iron, magnesium and calcium ions at relatively high concentrations. Applicability of the proposed sorbents was tested for Cu(II) determination in various kinds of water samples and the results were compared with those obtained with the use of ICP MS as a reference technique. Copper(II) determination in two certified

  1. Probabilistic sampling of finite renewal processes

    CERN Document Server

    Antunes, Nelson; 10.3150/10-BEJ321

    2012-01-01

    Consider a finite renewal process in the sense that interrenewal times are positive i.i.d. variables and the total number of renewals is a random variable, independent of interrenewal times. A finite point process can be obtained by probabilistic sampling of the finite renewal process, where each renewal is sampled with a fixed probability and independently of other renewals. The problem addressed in this work concerns statistical inference of the original distributions of the total number of renewals and interrenewal times from a sample of i.i.d. finite point processes obtained by sampling finite renewal processes. This problem is motivated by traffic measurements in the Internet in order to characterize flows of packets (which can be seen as finite renewal processes) and where the use of packet sampling is becoming prevalent due to increasing link speeds and limited storage and processing capacities.

  2. An On-Line Modeling Based Kalman Filtering Process for Time-Interval-Variable Sequences with Application to Astronomic Surveying

    Institute of Scientific and Technical Information of China (English)

    韩建国; 孙才红; 李彦琴

    2003-01-01

    The problem of variable sampling time interval which appears in application of Kalman Filtering is analyzed and the corresponding filtering process with or without present transition matrix is suggested, then an application experiment for astronomical surveying is introduced. In this process, the known stochastically variable sampling time intervals play the roles as deterministic input sequences of the state-space description, and the corresponding matrix and (if needed) state transition matrix can be established by performing real-time and structure-linear system identification.

  3. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  4. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples.

  5. Representative process sampling for reliable data analysis

    DEFF Research Database (Denmark)

    Julius, Lars Petersen; Esbensen, Kim

    2005-01-01

    Process sampling of moving streams of particulate matter, fluids and slurries (over time or space) or stationary one-dimensional (1-D) lots is often carried out according to existing tradition or protocol not taking the theory of sampling (TOS) into account. In many situations, sampling errors (s...

  6. How and When Accentuation Influences Temporally Selective Attention and Subsequent Semantic Processing during On-Line Spoken Language Comprehension: An ERP Study

    Science.gov (United States)

    Li, Xiao-qing; Ren, Gui-qin

    2012-01-01

    An event-related brain potentials (ERP) experiment was carried out to investigate how and when accentuation influences temporally selective attention and subsequent semantic processing during on-line spoken language comprehension, and how the effect of accentuation on attention allocation and semantic processing changed with the degree of…

  7. Application of a Mechanistic Model as a Tool for On-line Monitoring of Pilot Scale Filamentous Fungal Fermentation Processes - The Importance of Evaporation Effects

    DEFF Research Database (Denmark)

    Mears, Lisa; Stocks, Stuart M.; Albæk, Mads Orla

    2017-01-01

    block models the changing rates of formation of product, biomass, and water, and the rate of consumption of feed using standard, available on-line measurements. This parameter estimation block, is coupled to a mechanistic process model, which solves the current states of biomass, product, substrate......, dissolved oxygen and mass, as well as other process parameters including kLa, viscosity and partial pressure of CO2. State estimation at this scale requires a robust mass model including evaporation, which is a factor not often considered at smaller scales of operation.The model is developed using...... sensor at this scale, this allows for improved process monitoring, as well as opening up further possibilities for on-line control algorithms, utilizing these on-line model outputs. This article is protected by copyright. All rights reserved...

  8. On-line characterization of emulsions aiming equipment sizing and definition of primary processing conditions; Caracterizacao em tempo real de emulsoes visando o dimensionamento de equipamentos e a definicao das condicoes de processamento primario

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, Gloria M.S. [Fundacao Gorceix, Ouro Preto, MG (Brazil); Oliveira, Roberto C.G. de [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    In this work are presented the results of the test of emulsion generation, carried out in the Experimental Nucleus of PETROBRAS in Atalaia city Brazil, in which equipment for on-line measurement of droplet size distribution was tested, whose operation principle is of acoustic attenuation. One of the objectives of this study was the validation of this technology for on-line characterization of petroleum emulsions, aiming at the optimization of the sub sea or top side processing equipment. The emulsions had been on-line monitored by the acoustic spectrometer, installed downstream of a choke valve. Samples of generated emulsions had been collected in different points of the circuit and characterized off-line how much its stability, droplet size distribution (DSD), water cut and viscosity. Moreover, in some stages of the test a demulsifier was injected so as to verify the behavior of emulsions. The acoustic spectrometry technique demonstrated to be efficient in the on-line characterization of the droplet size distributions of emulsions generated in different operational conditions. The acoustic technique presented satisfactory performance, in view of the comparison of the values of median gotten on-line and off-line. (author)

  9. Discrete Equilibrium Sampling with Arbitrary Nonequilibrium Processes

    CERN Document Server

    Hamze, Firas

    2015-01-01

    We present a novel framework for performing statistical sampling, expectation estimation, and partition function approximation using \\emph{arbitrary} heuristic stochastic processes defined over discrete state spaces. Using a highly parallel construction we call the \\emph{sequential constraining process}, we are able to simultaneously generate states with the heuristic process and accurately estimate their probabilities, even when they are far too small to be realistically inferred by direct counting. After showing that both theoretically correct importance sampling and Markov chain Monte Carlo are possible using the sequential constraining process, we integrate it into a methodology called \\emph{state space sampling}, extending the ideas of state space search from computer science to the sampling context. The methodology comprises a dynamic data structure that constructs a robust Bayesian model of the statistics generated by the heuristic process subject to an accuracy constraint, the posterior Kullback-Leibl...

  10. An integrated sample pretreatment platform for quantitative N-glycoproteome analysis with combination of on-line glycopeptide enrichment, deglycosylation and dimethyl labeling

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Yejing; Qu, Yanyan; Jiang, Hao; Wu, Qi [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Zhang, Lihua, E-mail: lihuazhang@dicp.ac.cn [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); Yuan, Huiming [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); Zhou, Yuan [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Zhang, Xiaodan; Zhang, Yukui [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China)

    2014-06-23

    Highlights: • An integrated platform for quantitative N-glycoproteome analysis was established. • On-line enrichment, deglycosylation and labeling could be achieved within 160 min. • A N{sub 2}-assisted interface was applied to improve the compatibility of the platform. • The platform exhibited improved quantification accuracy, precision and throughput. - Abstract: Relative quantification of N-glycoproteomes shows great promise for the discovery of candidate biomarkers and therapeutic targets. The traditional protocol for quantitative analysis of glycoproteomes is usually off-line performed, and suffers from long sample preparation time, and the risk of sample loss or contamination due to manual manipulation. In this study, a novel integrated sample preparation platform for quantitative N-glycoproteome analysis was established, with combination of online N-glycopeptide capture by a HILIC column, sample buffer exchange by a N{sub 2}-assisted HILIC–RPLC interface, deglycosylation by a hydrophilic PNGase F immobilized enzymatic reactor (hIMER) and solid dimethyl labeling on a C18 precolumn. To evaluate the performance of such a platform, two equal aliquots of immunoglobulin G (IgG) digests were sequentially pretreated, followed by MALDI-TOF MS analysis. The signal intensity ratio of heavy/light (H/L) labeled deglycosylated peptides with the equal aliquots was 1.00 (RSD = 6.2%, n = 3), much better than those obtained by the offline protocol, with H/L ratio as 0.76 (RSD = 11.6%, n = 3). Additionally, the total on-line sample preparation time was greatly shortened to 160 min, much faster than that of offline approach (24 h). Furthermore, such an integrated pretreatment platform was successfully applied to analyze the two kinds of hepatocarcinoma ascites syngeneic cell lines with high (Hca-F) and low (Hca-P) lymph node metastasis rates. For H/L labeled Hca-P lysates with the equal aliquots, 99.6% of log 2 ratios (H/L) of quantified glycopeptides ranged from −1

  11. Representative process sampling for reliable data analysis

    DEFF Research Database (Denmark)

    Julius, Lars Petersen; Esbensen, Kim

    2005-01-01

    (sampling variances) can be reduced greatly however, and sampling biases can be eliminated completely, by respecting a simple set of rules and guidelines provided by TOS. A systematic approach for description of process heterogeneity furnishes in-depth knowledge about the specific variability of any 1-D lot...... of any hidden cycle, eliminating the risk of underestimating process variation. A brief description of selected hardware for extraction of samples from 1-D lots is provided in order to illustrate the key issues to consider when installing new, or optimizing existing sampling devices and procedures...

  12. Accelerated solvent extraction followed by on-line solid-phase extraction coupled to ion trap LC/MS/MS for analysis of benzalkonium chlorides in sediment samples

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2002-01-01

    Benzalkonium chlorides (BACs) were successfully extracted from sediment samples using a new methodology based on accelerated solvent extraction (ASE) followed by an on-line cleanup step. The BACs were detected by liquid chromatography/ion trap mass spectrometry (LC/MS) or tandem mass spectrometry (MS/MS) using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the high sensitivity offered by the ion trap MS/MS. The effects of solvent type and ASE operational variables, such as temperature and pressure, were evaluated. After optimization, a mixture of acetonitrile/water (6:4 or 7:3) was found to be most efficient for extracting BACs from the sediment samples. Extraction recoveries ranged from 95 to 105% for C12 and C14 homologues, respectively. Total method recoveries from fortified sediment samples, using a cleanup step followed by ASE, were 85% for C12BAC and 79% for C14-BAC. The methodology developed in this work provides detection limits in the subnanogram per gram range. Concentrations of BAC homologues ranged from 22 to 206 ??g/kg in sediment samples from different river sites downstream from wastewater treatment plants. The high affinity of BACs for soil suggests that BACs preferentially concentrate in sediment rather than in water.

  13. Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies

    Directory of Open Access Journals (Sweden)

    Katty Wan

    2010-05-01

    Full Text Available A fully automated 96-well On-Line Solid Phase Extraction (SPE followed by High Performance Liquid Chromatography (HPLC-Tandem Mass Spectrometric (MS/MS method for the determination of ABT-925 (2-{3-[4-(2-tert-Butyl-6-trifluoromethyl-pyrimidin-4-yl-piperazin-1-yl-propyl-sulfanyl}-3H-pyrimidin-4-one fumarate in human plasma was developed, validated and utilized in Phase II clinical studies. 50 µL of plasma sample was fortified with internal standard (IS, d8-ABT-925 and extracted on-line with Cohesive Turbo Flow Cyclone P HTLC column. The chromatographic separation was performed on Aquasil C18 (3 μm 50 × 3 mm HPLC column with a mobile phase consisting of 50/50/0.1 (v/v/v ACN/H2O/formic acid. The mass spectrometric measurement was conducted under positive ion mode using multiple reaction monitoring (MRM of m/z 457.4 → 329.4 for analyte and m/z 465.5 → 337.5 for IS.The peak area ratio (analyte/IS was used to quantitate ABT-925. A dynamic range of 0.0102 μg/mL to 5.24 μg/mL was established after the validation. The validated method was then used for two Phase II studies. To demonstrate the method reproducibility, approximately 10% of the incurred samples from one study were repeated in singlet. The repeated values were compared to the initial values. All repeated values agreed within ±15% of the mean values.

  14. Quantitative Determination of ABT-925 in Human Plasma by On-Line SPE and LC-MS/MS: Validation and Sample Analysis in Phase II Studies.

    Science.gov (United States)

    Wan, Katty; Rieser, Matthew; El-Shourbagy, Tawakol

    2010-05-04

    A fully automated 96-well On-Line Solid Phase Extraction (SPE) followed by High Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometric (MS/MS) method for the determination of ABT-925 (2-{3-[4-(2-tert-Butyl-6-trifluoromethyl-pyrimidin-4-yl)-piperazin-1-yl)-propyl-sulfanyl}-3H-pyrimidin-4-one fumarate) in human plasma was developed, validated and utilized in Phase II clinical studies. 50 µL of plasma sample was fortified with internal standard (IS, d8-ABT-925) and extracted on-line with Cohesive Turbo Flow Cyclone P HTLC column. The chromatographic separation was performed on Aquasil C18 (3 μm 50 × 3 mm) HPLC column with a mobile phase consisting of 50/50/0.1 (v/v/v) ACN/H₂O/formic acid. The mass spectrometric measurement was conducted under positive ion mode using multiple reaction monitoring (MRM) of m/z 457.4 → 329.4 for analyte and m/z 465.5 → 337.5 for IS.The peak area ratio (analyte/IS) was used to quantitate ABT-925. A dynamic range of 0.0102 μg/mL to 5.24 μg/mL was established after the validation. The validated method was then used for two Phase II studies. To demonstrate the method reproducibility, approximately 10% of the incurred samples from one study were repeated in singlet. The repeated values were compared to the initial values. All repeated values agreed within ±15% of the mean values.

  15. Sometimes Children Are as Good as Adults: The Pragmatic Use of Prosody in Children's On-Line Sentence Processing

    Science.gov (United States)

    Zhou, Peng; Crain, Stephen; Zhan, Likan

    2012-01-01

    This study examined 4-year-old Mandarin-speaking children's sensitivity to prosodic cues in resolving speech act ambiguities, using eye-movement recordings. Most previous on-line studies have focused on children's use of prosody in resolving structural ambiguities. Although children have been found to be sensitive to prosodic information, they use…

  16. Determination of palladium by on-line flow-injection direct spectrophotometry in environmental samples using 2,2'-furyldioxime as a chelator.

    Science.gov (United States)

    Saçmacı, Serife; Kartal, Senol

    2013-05-15

    A new, sensitive, and accurate on-line spectrophotometric method for the determination of palladium was developed. The method is based on the reaction between Pd(II) and 2,2'-furyldioxime in nitric acid medium. The absorbance of the complex is spectrophotometrically measured at 410 nm with a diode-array detector. Several factors that influence the analytical performance of the method such as acidity, flow rates of the reagent and sample solutions, concentration of the reagent, and effect of interfering ions were investigated. The calibration curve was obtained in the range of 0.01-10.0 mg L(-1) Pd(II). The detection limit was 0.1 µg L(-1) while the relative standard deviation of the method was found to be 1.2% (n=13) at 4.0 mg L(-1) Pd(II) level. The sample throughput was 275 h(-1). The method was successfully applied to the determination of palladium in catalytic converter, anodic slime, road sediment, ore, and water samples.

  17. On-line solid-phase extraction coupled to ultra-performance liquid chromatography with tandem mass spectrometry detection for the determination of benzotriazole UV stabilizers in coastal marine and wastewater samples

    Energy Technology Data Exchange (ETDEWEB)

    Montesdeoca-Esponda, Sarah; Sosa-Ferrera, Zoraida; Santana-Rodriguez, Jose Juan [Universidad de Las Palmas de Gran Canaria, Departamento de Quimica, Las Palmas de Gran Canaria (Spain)

    2012-05-15

    Benzotriazoles are a group of UV absorbing compounds considered emerging contaminants that are used in different personal care products, and therefore, it is of high interest to develop sensitive and fast methods for investigating their presence in the environment. In this work, we present the development and application of a novel method based on on-line solid-phase extraction coupled to ultra-performance liquid chromatography with tandem mass spectrometry detection (SPE-UPLC-MS/MS) for the determination of seven benzotriazole UV stabilizers (BUVSs) in coastal marine and wastewater samples. This process is compared with a conventional off-line SPE procedure followed by UPLC-MS/MS. The parameters affecting the performance of the sample preparation and determination processes were evaluated. The results indicate that the on-line procedure provides for better sensitivity and reproducibility and is faster and easier than the off-line procedure. The detection limits and quantification limits achieved were in the range of 0.6-4.1 ng circle L{sup -1} and 2.1-14 ng circle L{sup -1} and relative standard deviation between 6.2 and 10 %. The developed method was applied to coastal marine and wastewater samples from Gran Canaria Island (Spain). All of the BUVSs studied were detected in the samples from wastewater treatment plants and two were found in the seawater samples (UV P in the range of 2.8-4.4 ng circle L{sup -1} and UV 360 between 3.6 and 5.2 ng circle L{sup -1}). (orig.)

  18. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, Mirna, E-mail: msigrist@fiq.unl.edu.ar [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Albertengo, Antonela; Beldomenico, Horacio [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Tudino, Mabel [Laboratorio de Analisis de Trazas, Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE, Facultad de Ciencias Exactas y Naturales, Pabellon II, Ciudad Universitaria (1428), Buenos Aires (Argentina)

    2011-04-15

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH{sub 3} generation using 3.5 mol L{sup -1} HCl as carrier solution and 0.35% (m/v) NaBH{sub 4} in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, HPO{sub 4}{sup 2-}, HCO{sub 3}{sup -} on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C{sub 6}H{sub 8}O{sub 6} solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 {mu}g L{sup -1} and 0.6 {mu}g L{sup -1} for As(III) and inorganic total As, respectively, were obtained for a 500 {mu}L sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h{sup -1}. The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species

  19. Theoretical and experimental comparison of one dimensional versus on-line comprehensive two dimensional liquid chromatography for optimized sub-hour separations of complex peptide samples.

    Science.gov (United States)

    Sarrut, Morgan; Rouvière, Florent; Heinisch, Sabine

    2017-05-19

    This study was devoted to the search for conditions leading to highly efficient sub-hour separations of complex peptide samples with the objective of coupling to mass spectrometry. In this context, conditions for one dimensional reversed phase liquid chromatography (1D-RPLC) were optimized on the basis of a kinetic approach while conditions for on-line comprehensive two-dimensional liquid chromatography using reversed phase in both dimensions (on-line RPLCxRPLC) were optimized on the basis of a Pareto-optimal approach. Maximizing the peak capacity while minimizing the dilution factor for different analysis times (down to 5min) were the two objectives under consideration. For gradient times between 5 and 60min, 15cm was found to be the best column length in RPLC with sub-2μm particles under 800bar as system pressure. In RPLCxRPLC, for less than one hour as first dimension gradient time, the sampling rate was found to be a key parameter in addition to conventional parameters including column dimension, particle size, flow-rate and gradient conditions in both dimensions. It was shown that the optimum sampling rate was as low as one fraction per peak for very short gradient times (i.e. below 10min). The quality descriptors obtained under optimized RPLCxRPLC conditions were compared to those obtained under optimized RPLC conditions. Our experimental results for peptides, obtained with state of the art instrumentation, showed that RPLCxRPLC could outperform 1D-RPLC for gradient times longer than 5min. In 60min, the same peak intensity (same dilution) was observed with both techniques but with a 3-fold lower injected amount in RPLCxRPLC. A significant increase of the signal-to-noise ratio mainly due to a strong noise reduction was observed in RPLCxRPLC-MS compared to the one in 1D-RPLC-MS making RPLCxRPLC-MS a promising technique for peptide identification in complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Determination of Se in biological samples by axial view inductively coupled plasma optical emission spectrometry after digestion with aqua regia and on-line chemical vapor generation

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Eder Jose dos [Instituto de Tecnologia do Parana (TECPAR), 81350-010 Curitiba, PR (Brazil)], E-mail: eder@tecpar.br; Herrmann, Amanda Beatriz; Kulik de Caires, Suzete [Instituto de Tecnologia do Parana (TECPAR), 81350-010 Curitiba, PR (Brazil); Azzolin Frescura, Vera Lucia; Curtius, Adilson Jose [Departamento de Quimica, Universidade Federal de Santa Catarina (UFSC), 880400-900 Florianopolis, SC (Brazil)

    2009-06-15

    A simple and fast method for the determination of Se in biological samples, including food, by axial view inductively coupled plasma optical emission spectrometry using on-line chemical vapor generation (CVG-ICP OES) is proposed. The concentrations of HCl and NaBH{sub 4}, used in the chemical vapor generation were optimized by factorial analysis. Six certified materials (non-fat milk powder, lobster hepatopancreas, human hair, whole egg powder, oyster tissue, and lyophilised pig kidney) were treated with 10 mL of aqua regia in a microwave system under reflux for 15 min followed by additional 15 min in an ultrasonic bath. The solutions were transferred to a 100 mL volumetric flask and the final volume was made up with water. The Se was determined directly in these solutions by CVG-ICP OES, using the analytical line at 196.026 nm. Calibration against aqueous standards in 10% v/v aqua regia in the concentration range of 0.5-10.0 {mu}g L{sup -} {sup 1} Se(IV) was used for the analysis. The quantification limit, considering a 0.5 g sample weight in a final volume of 100 mL{sup -} {sup 1} was 0.10 {mu}g g{sup -} {sup 1}. The obtained concentration values were in agreement with the total certified concentrations, according to the t-test for a 95% confidence level.

  1. Capture and identification of the volatile components in crude and processed herbal medicines through on-line purge and trap technique coupled with GC × GC-TOF MS.

    Science.gov (United States)

    Cao, Gang; Xu, Zhiwei; Wu, Xin; Li, Qingli; Chen, Xiaocheng

    2014-01-01

    This work aimed to investigate the volatile components in crude and processed herbal medicines (HMs). Using Atractylodis Macrocephalae Rhizoma (AMR) as a model HM, the volatile components were captured through on-line purge and trap technique and identified by using comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC × GC-TOF MS) system. A total of 224 and 171 volatile compounds were identified in crude and processed AMR samples, respectively. After frying with honey-bran, 52 compounds which were found in crude AMR samples disappeared in processed AMR samples, and 15 compounds were newly generated in processed AMR. The established method can be applied in different research areas such as HM and food processing.

  2. Pierre Gy's sampling theory and sampling practice heterogeneity, sampling correctness, and statistical process control

    CERN Document Server

    Pitard, Francis F

    1993-01-01

    Pierre Gy's Sampling Theory and Sampling Practice, Second Edition is a concise, step-by-step guide for process variability management and methods. Updated and expanded, this new edition provides a comprehensive study of heterogeneity, covering the basic principles of sampling theory and its various applications. It presents many practical examples to allow readers to select appropriate sampling protocols and assess the validity of sampling protocols from others. The variability of dynamic process streams using variography is discussed to help bridge sampling theory with statistical process control. Many descriptions of good sampling devices, as well as descriptions of poor ones, are featured to educate readers on what to look for when purchasing sampling systems. The book uses its accessible, tutorial style to focus on professional selection and use of methods. The book will be a valuable guide for mineral processing engineers; metallurgists; geologists; miners; chemists; environmental scientists; and practit...

  3. On-line near-infrared spectroscopy optimizing and monitoring biotransformation process of γ-aminobutyric acid

    Directory of Open Access Journals (Sweden)

    Guoyu Ding

    2016-06-01

    Full Text Available Near-infrared spectroscopy (NIRS with its fast and nondestructive advantages can be qualified for the real-time quantitative analysis. This paper demonstrates that NIRS combined with partial least squares (PLS regression can be used as a rapid analytical method to simultaneously quantify l-glutamic acid (l-Glu and γ-aminobutyric acid (GABA in a biotransformation process and to guide the optimization of production conditions when the merits of NIRS are combined with response surface methodology. The high performance liquid chromatography (HPLC reference analysis was performed by the o-phthaldialdehyde pre-column derivatization. NIRS measurements of two batches of 141 samples were firstly analyzed by PLS with several spectral pre-processing methods. Compared with those of the HPLC reference analysis, the resulting determination coefficients (R2, root mean square error of prediction (RMSEP and residual predictive deviation (RPD of the external validation for the l-Glu concentration were 99.5%, 1.62 g/L, and 11.3, respectively. For the GABA concentration, R2, RMSEP, and RPD were 99.8%, 4.00 g/L, and 16.4, respectively. This NIRS model was then used to optimize the biotransformation process through a Box-Behnken experimental design. Under the optimal conditions without pH adjustment, 200 g/L l-Glu could be catalyzed by 7148 U/L glutamate decarboxylase (GAD to GABA, reaching 99% conversion at the fifth hour. NIRS analysis provided timely information on the conversion from l-Glu to GABA. The results suggest that the NIRS model can not only be used for the routine profiling of enzymatic conversion, providing a simple and effective method of monitoring the biotransformation process of GABA, but also be considered to be an optimal tool to guide the optimization of production conditions.

  4. On-line near-infrared spectroscopy optimizing and monitoring biotransformation process ofγ-aminobutyric acid$

    Institute of Scientific and Technical Information of China (English)

    Guoyu Ding; Yuanyuan Hou; Jiamin Peng; Yunbing Shen; Min Jiang; Gang Bai

    2016-01-01

    Near-infrared spectroscopy (NIRS) with its fast and nondestructive advantages can be qualified for the real-time quantitative analysis. This paper demonstrates that NIRS combined with partial least squares (PLS) regression can be used as a rapid analytical method to simultaneously quantify L-glutamic acid (L-Glu) andγ-aminobutyric acid (GABA) in a biotransformation process and to guide the optimization of production conditions when the merits of NIRS are combined with response surface methodology. The high performance liquid chromatography (HPLC) reference analysis was performed by the o-phthaldialdehyde pre-column derivatization. NIRS measurements of two batches of 141 samples were firstly analyzed by PLS with several spectral pre-processing methods. Compared with those of the HPLC reference analysis, the resulting determination coefficients (R2), root mean square error of prediction (RMSEP) and residual predictive deviation (RPD) of the external validation for the L-Glu concentration were 99.5%, 1.62 g/L, and 11.3, respectively. For the GABA concentration, R2, RMSEP, and RPD were 99.8%, 4.00 g/L, and 16.4, re-spectively. This NIRS model was then used to optimize the biotransformation process through a Box-Behnken experimental design. Under the optimal conditions without pH adjustment, 200 g/L L-Glu could be catalyzed by 7148 U/L glutamate decarboxylase (GAD) to GABA, reaching 99%conversion at the fifth hour. NIRS analysis provided timely information on the conversion from L-Glu to GABA. The results suggest that the NIRS model can not only be used for the routine profiling of enzymatic conversion, providing a simple and effective method of monitoring the biotransformation process of GABA, but also be considered to be an optimal tool to guide the optimization of production conditions.

  5. On-line analysis of secondary ozonides from cyclohexene and D-limonene ozonolysis using atmospheric sampling townsend discharge ionization mass spectrometry

    Science.gov (United States)

    Nøjgaard, J. K.; Nørgaard, A. W.; Wolkoff, P.

    An on-line technique has been developed for analysis of gas-phase oxidation products formed in a reaction flow tube using different reaction times, concentrations and humidities. Products of ozonolysis, including thermally labile secondary ozonides (SOZ), were directly introduced into an atmospheric sampling townsend discharge ionization (ASTDI) source coupled to a triple quadrupole mass spectrometer (MS). Instant changes in the product composition were monitored in the total-ion chromatogram, or by fragment ions in the collision activated dissociation mass spectra by use of MS/MS scan techniques. Assignment of the individual ions was accomplished by inspection of the products' mass spectra obtained by pre-concentration of the gas phase on a dedicated short column followed by chromatographic analysis. The observed reaction products correspond to those identified with other techniques. Of relevance for future mechanistic modelling, is the point that conditions of excess D-limonene favoured the formation of the D-limonene SOZ (major product), which was observed to be quite stable in dry and humid air, without oxidants. The D-limonene/ozone ratio was observed to be crucial for the stability of the SOZ, because it is prone to ozonolysis, and no SOZ could be detected in completely reacted 1:1 mixtures.

  6. On-line hydrogen-isotope measurements of organic samples using elemental chromium: An extension for high temperature elemental-analyzer techniques

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B.; Meijer, Harro A.J.; Brand, Willi A.; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ2H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ2H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  7. Surface studies of plasma processed Nb samples

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, Puneet V. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Doleans, Marc [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Hannah, Brian S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Afanador, Ralph [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Stewart, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Mammosser, John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Howell, Matthew P [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Saunders, Jeffrey W [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Degraff, Brian D [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS); Kim, Sang-Ho [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Spallation Neutron Source (SNS)

    2015-01-01

    Contaminants present at top surface of superconducting radio frequency (SRF) cavities can act as field emitters and restrict the cavity accelerating gradient. A room temperature in-situ plasma processing technology for SRF cavities aiming to clean hydrocarbons from inner surface of cavities has been recently developed at the Spallation Neutron Source (SNS). Surface studies of the plasma-processed Nb samples by Secondary ion mass spectrometry (SIMS) and Scanning Kelvin Probe (SKP) showed that the NeO2 plasma processing is very effective to remove carbonaceous contaminants from top surface and improves the surface work function by 0.5 to 1.0 eV.

  8. Combining high-performance liquid chromatography with on-line microdialysis sampling for the simultaneous determination of ascorbyl glucoside, kojic acid, and niacinamide in bleaching cosmetics.

    Science.gov (United States)

    Lin, Cheng-Hui; Wu, Hsin-Lung; Huang, Yeou-Lih

    2007-01-02

    We have used on-line microdialysis sampling coupled with high-performance liquid chromatography and UV-vis detection to simultaneously determine the contents of ascorbyl glucoside (AA-2G), kojic acid (KA), and niacinamide (VitB(3)) in commercial bleaching cosmetics. Our results indicate that AA-2G, KA, and VitB(3) separated well within 4.5 min on a reverse-phase Hypersil Fluophase PFP column when eluting with 0.020 M phosphate buffer solution in 40% (v/v) methanol at pH 5.5. The calibration curves were linear over the ranges 0.068-304, 0.071-284, and 0.024-488 microg mL(-1) for AA-2G, KA, and VitB(3), respectively, with correlation coefficients for the linear regression analyses falling within the range 0.9982-0.9999. The detection limits for AA-2G, KA, and VitB(3) were 0.01, 0.01, and 0.007 microg mL(-1), respectively. The detection wavelength was robust when the levels of the analytes in the samples were high (0.1-2%). The analytes were all detected using ultraviolet light (254 nm). The compounds diffuse through the membrane more readily when KA and VitB(3) are in their molecular forms and AA-2G is ionized. The recoveries were in the range 92-106% with good reproducibility (R.S.D.=3.9-8.7%). We used this procedure to assay six commercially available bleaching cosmetics; our results confirmed not only the precision of the method but also the claims made on the labels of the cosmetics. This approach provides a very simple means to determine the contents of AA-2G, KA, and VitB(3) in various dosages in bleaching cosmetics.

  9. Cloud point extraction with/without chelating agent on-line coupled with inductively coupled plasma optical emission spectrometry for the determination of trace rare earth elements in biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Li Yingjie [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu Bin, E-mail: binhu@whu.edu.cn [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2010-02-15

    The on-line incorporation of cloud point extraction (CPE) with/without 8-hydroxyquinoline (8-Ox) as chelating agent into flow injection analysis associated with inductively coupled plasma optical emission spectrometry (ICP-OES) for determining trace rare earth elements (REEs) is presented and evaluated. The significant parameters affecting on-line cloud point extraction of REEs such as sample pH, flow rate, 8-Ox concentration, Triton X-114 concentration were systematically studied. Under the optimized conditions, with the consumption of 3.0 mL sample solution, the limits of detection (3{sigma}) were ranged from 41.4 pg mL{sup -1} (Yb) to 448 pg mL{sup -1} (Gd) with relative standard deviations (RSDs) of 1.0% (Eu)-5.9% (Sm) for on-line CPE-ICP-OES with 8-Ox as chelating agent, and 69.0 pg mL{sup -1} (Sc) to 509.5 pg mL{sup -1} (Sm) with RSDs of 2.9% (Yb)-7.5% (Ho) for on-line CPE-ICP-OES without 8-Ox as chelating agent, respectively. The sample throughput of 17 samples h{sup -1} was obtained for both systems. The developed methods of on-line CPE-ICP-OES were validated by the analysis of certified reference material (GBW07605, tea leaves) and real biological samples of pig liver, Auricularia auricula and mushroom.

  10. On-line monitoring the extract process of Fu-fang Shuanghua oral solution using near infrared spectroscopy and different PLS algorithms

    Science.gov (United States)

    Kang, Qian; Ru, Qingguo; Liu, Yan; Xu, Lingyan; Liu, Jia; Wang, Yifei; Zhang, Yewen; Li, Hui; Zhang, Qing; Wu, Qing

    2016-01-01

    An on-line near infrared (NIR) spectroscopy monitoring method with an appropriate multivariate calibration method was developed for the extraction process of Fu-fang Shuanghua oral solution (FSOS). On-line NIR spectra were collected through two fiber optic probes, which were designed to transmit NIR radiation by a 2 mm flange. Partial least squares (PLS), interval PLS (iPLS) and synergy interval PLS (siPLS) algorithms were used comparatively for building the calibration regression models. During the extraction process, the feasibility of NIR spectroscopy was employed to determine the concentrations of chlorogenic acid (CA) content, total phenolic acids contents (TPC), total flavonoids contents (TFC) and soluble solid contents (SSC). High performance liquid chromatography (HPLC), ultraviolet spectrophotometric method (UV) and loss on drying methods were employed as reference methods. Experiment results showed that the performance of siPLS model is the best compared with PLS and iPLS. The calibration models for AC, TPC, TFC and SSC had high values of determination coefficients of (R2) (0.9948, 0.9992, 0.9950 and 0.9832) and low root mean square error of cross validation (RMSECV) (0.0113, 0.0341, 0.1787 and 1.2158), which indicate a good correlation between reference values and NIR predicted values. The overall results show that the on line detection method could be feasible in real application and would be of great value for monitoring the mixed decoction process of FSOS and other Chinese patent medicines.

  11. Determination of 2-propanol in surface cleaning solutions used for copper continuous casting process by flow injection-spectrophotometric detection with on-line column separation.

    Science.gov (United States)

    Hayashibe, Yutaka; Tokuda, Masahiro; Takeya, Minoru

    2003-09-01

    A flow-injection system has been developed for the determination of 2-propanol in the surface cleaning solutions used in the copper continuous cast rod making system. Adsorption chromatography in nitric acid medium was used for the on-line separation of oily substances in the sample solution. Cerium(IV) diammonium nitrate was utilized as the chromogenic reagent for the spectrophotometric detection of 2-propanol. The system permits a throughput of one sample per hour for the oily sample, and of 12 samples per hour for the none-oily sample. The reproducibility has been proven to be satisfactory with a relative standard deviation of less than 6.0% (2.2%(V/V) 2-propanol level, n = 23). The detection limit is 0.01% (V/V).

  12. Separation and quantification of {sup 238}U, {sup 232}Th and rare earths in monazite samples by ion chromatography coupled with on-line flow scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Borai, E.H.; Mady, A.S

    2002-10-01

    An alternative procedure has been described for efficient separation and quantitative determination of uranium (U), thorium (Th) and rare earth elements (REEs) in monazite mineral by high performance ion chromatographic system (IC). Different variables affecting the distribution coefficient, the retention and hence separation efficiency such as eluent flow rate and concentrations of HCl and ammonium sulfate (NH{sub 4}){sub 2}SO{sub 4} containing the mobile phase were studied. The developed separation protocol of U, Th and REEs was optimized using an Ion Pac CS5 separation column followed by post-column derivatization reaction with Arsenaso III and UV-VIS spectrophotometeric detection. Comparative evaluation of U, Th and REEs concentration in monazite mineral was demonstrated using two different on-line detection modes including flow through cell scintillation detector (FSD) and UV-VIS spectrophotometer. Response of the FSD was found to be linear over the full range of activities investigated (4-100 Bq). The lower limits of detection (LLD) for the investigated radionuclides were 3.0{+-}0.1 Bq for {sup 238}U and 6.0{+-}0.1 Bq for {sup 232}Th. The detection of {sup 238}U and {sup 232}Th by FSD shows good agreement with the corresponding determination by UV-VIS spectrophotometer. The content of ThO{sub 2} and U{sub 3}O{sub 8} in monazite sample were found to be 4.7{+-}0.1% and 0.42{+-}0.04% using UV-VIS detector and 4.3{+-}0.1% and 0.45{+-}0.1% using FSD, respectively.

  13. On-line cloud point extraction combined with electrothermal vaporization inductively coupled plasma atomic emission spectrometry for the speciation of inorganic antimony in environmental and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Li Yingjie [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Hu Bin [Department of Chemistry, Wuhan University, Wuhan 430072 (China)]. E-mail: binhu@whu.edu.cn; Jiang Zucheng [Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2006-08-25

    A new method for the determination of inorganic Sb species by on-line cloud point extraction combined with electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES) is presented and evaluated. The method is based on the complexation of Sb(III) with pyrrolidine dithiocarbamate (PDC) which form an hydrophobic complex at pH 5.5 and subsequently enter surfactant-rich phase at pH 5.5, whereas Sb(V) remained in aqueous solutions. The preconcentration step is mediated by micelles of the non-ionic surfactant Triton X-114 with ammonium pyrrolidine dithiocarbamate (APDC). The micellar system containing the complex was loaded into the FIA manifold at a flow rate of 2.5 mL min{sup -1}, and the surfactant-rich phase was retained in a microcolumn packed with absorbent cotton, at pH 5.5. After the surfactant-rich phase was eluted with 100 {mu}L acetonitrile, it was determined by ETV-ICP-AES. Sb(V) is reduced to Sb(III) by L-cysteine prior to determined total Sb, and its assay is based on subtracting Sb(III) from total antimony. The main factors affecting separation/preconcentration and the vaporization behavior of analyte in graphite tube were investigated in detail. Under the optimized conditions, the precision relative standard deviation (R.S.D.) for eight replicate measurements of 0.2 {mu}g mL{sup -1} Sb(III) was 4.3%. The apparent concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for ETV-ICP-AES detection and in the initial solution, was 872 for Sb(III). The limit of detection (LOD) for Sb(III) was 0.09 {mu}g L{sup -1}. The proposed method was successfully applied for the speciation of inorganic antimony in different water samples and urine sample with satisfactory results.

  14. Using eye-tracking to study the on-line processing of case-marking information among intermediate L2 learners of German

    Science.gov (United States)

    Jackson, Carrie N.; Dussias, Paola E.; Hristova, Adelina

    2012-01-01

    This study uses eye-tracking to examine the processing of case-marking information in ambiguous subject- and object-first wh-questions in German. The position of the lexical verb was also manipulated via verb tense to investigate whether verb location influences how intermediate L2 learners process L2 sentences. Results show that intermediate L2 German learners were sensitive to case-marking information, exhibiting longer processing times on subject-first than object-first sentences, regardless of verb location. German native speakers exhibited the opposite word order preference, with longer processing times on object-first than subject-first sentences, replicating previous findings. These results are discussed in light of current L2 processing research, highlighting how methodological constraints influence researchers’ abilities to measure the on-line processing of morphosyntactic information among intermediate L2 learners. PMID:23493761

  15. Determination of thromboxanes, leukotrienes and lipoxins using high-temperature capillary liquid chromatography-tandem mass spectrometry and on-line sample preparation

    DEFF Research Database (Denmark)

    Dahl, Sandra Rinne; Kleiveland, Charlotte Ramstad; Kassem, Moustapha

    2009-01-01

    An on-line strong cation-exchange (SCX)-reversed-phase (RP) capillary liquid chromatographic (cLC) method with ion-trap tandem mass spectrometric (IT-MS/MS) detection for the simultaneous determination of thromboxane (TX) B(2), TXB(3), leukotriene (LT) B(4), LTD(4) and lipoxin (LX) A(4) in cell...

  16. On-line Sweeping Sample Concentration in Micellar Electrokinetic Chromatography with Enhanced Sensitivity for the Determination of Carbamazepine in Human Serum

    Institute of Scientific and Technical Information of China (English)

    Dan Dan HAN; Chun WANG; Zhi WANG; Qiu Hua WU; Xiao Huan ZANG

    2006-01-01

    A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodiode array detection. Under the optimal conditions, the method has been successfully applied to the analysis of CBZ in human serum.

  17. Static sampling of dynamic processes - a paradox?

    Science.gov (United States)

    Mälicke, Mirko; Neuper, Malte; Jackisch, Conrad; Hassler, Sibylle; Zehe, Erwin

    2017-04-01

    Environmental systems monitoring aims at its core at the detection of spatio-temporal patterns of processes and system states, which is a pre-requisite for understanding and explaining their baffling heterogeneity. Most observation networks rely on distributed point sampling of states and fluxes of interest, which is combined with proxy-variables from either remote sensing or near surface geophysics. The cardinal question on the appropriate experimental design of such a monitoring network has up to now been answered in many different ways. Suggested approaches range from sampling in a dense regular grid using for the so-called green machine, transects along typical catenas, clustering of several observations sensors in presumed functional units or HRUs, arrangements of those cluster along presumed lateral flow paths to last not least a nested, randomized stratified arrangement of sensors or samples. Common to all these approaches is that they provide a rather static spatial sampling, while state variables and their spatial covariance structure dynamically change in time. It is hence of key interest how much of our still incomplete understanding stems from inappropriate sampling and how much needs to be attributed to an inappropriate analysis of spatial data sets. We suggest that it is much more promising to analyze the spatial variability of processes, for instance changes in soil moisture values, than to investigate the spatial variability of soil moisture states themselves. This is because wetting of the soil, reflected in a soil moisture increase, is causes by a totally different meteorological driver - rainfall - than drying of the soil. We hence propose that the rising and the falling limbs of soil moisture time series belong essentially to different ensembles, as they are influenced by different drivers. Positive and negative temporal changes in soil moisture need, hence, to be analyzed separately. We test this idea using the CAOS data set as a benchmark

  18. GEM-AQ, an on-line global multiscale chemical weather system: model description and evaluation of gas phase chemistry processes

    Directory of Open Access Journals (Sweden)

    J. W. Kaminski

    2007-10-01

    Full Text Available Tropospheric chemistry and air quality processes were implemented on-line in the Global Environmental Multiscale model. The integrated model, GEM-AQ, has been developed as a platform to investigate chemical weather at scales from global to urban. The model was exercised for five years (2001–2005 to evaluate its ability to simulate seasonal variations and regional distributions of trace gases such as ozone, nitrogen dioxide and carbon monoxide on the global scale. The model results presented are compared with observations from satellites, aircraft measurement campaigns and balloon sondes.

  19. On-line monitoring of extraction process of Flos Lonicerae Japonicae using near infrared spectroscopy combined with synergy interval PLS and genetic algorithm

    Science.gov (United States)

    Yang, Yue; Wang, Lei; Wu, Yongjiang; Liu, Xuesong; Bi, Yuan; Xiao, Wei; Chen, Yong

    2017-07-01

    There is a growing need for the effective on-line process monitoring during the manufacture of traditional Chinese medicine to ensure quality consistency. In this study, the potential of near infrared (NIR) spectroscopy technique to monitor the extraction process of Flos Lonicerae Japonicae was investigated. A new algorithm of synergy interval PLS with genetic algorithm (Si-GA-PLS) was proposed for modeling. Four different PLS models, namely Full-PLS, Si-PLS, GA-PLS, and Si-GA-PLS, were established, and their performances in predicting two quality parameters (viz. total acid and soluble solid contents) were compared. In conclusion, Si-GA-PLS model got the best results due to the combination of superiority of Si-PLS and GA. For Si-GA-PLS, the determination coefficient (Rp2) and root-mean-square error for the prediction set (RMSEP) were 0.9561 and 147.6544 μg/ml for total acid, 0.9062 and 0.1078% for soluble solid contents, correspondingly. The overall results demonstrated that the NIR spectroscopy technique combined with Si-GA-PLS calibration is a reliable and non-destructive alternative method for on-line monitoring of the extraction process of TCM on the production scale.

  20. Formal and informal contracting processes in the competitive dialogue procedure: a multiple case-study (on-line)

    NARCIS (Netherlands)

    Hoezen, M.E.L.; Voordijk, J.T.; Dewulf, G.P.M.R.

    2012-01-01

    The competitive dialogue (CD) procedure aims to align the complex demands of principals with possible solutions that contractors have to offer. It is, however, unclear how formal and informal structures and processes in the CD are interrelated and how they determine its effectiveness. The major ques

  1. Near-Infrared Spectroscopy as an Analytical Process Technology for the On-Line Quantification of Water Precipitation Processes during Danhong Injection

    Directory of Open Access Journals (Sweden)

    Xuesong Liu

    2015-01-01

    Full Text Available This paper used near-infrared (NIR spectroscopy for the on-line quantitative monitoring of water precipitation during Danhong injection. For these NIR measurements, two fiber optic probes designed to transmit NIR radiation through a 2 mm flow cell were used to collect spectra in real-time. Partial least squares regression (PLSR was developed as the preferred chemometrics quantitative analysis of the critical intermediate qualities: the danshensu (DSS, (R-3, 4-dihydroxyphenyllactic acid, protocatechuic aldehyde (PA, rosmarinic acid (RA, and salvianolic acid B (SAB concentrations. Optimized PLSR models were successfully built and used for on-line detecting of the concentrations of DSS, PA, RA, and SAB of water precipitation during Danhong injection. Besides, the information of DSS, PA, RA, and SAB concentrations would be instantly fed back to site technical personnel for control and adjustment timely. The verification experiments determined that the predicted values agreed with the actual homologic value.

  2. Replication methods and tools in high-throughput cultivation processes - recognizing potential variations of growth and product formation by on-line monitoring

    Directory of Open Access Journals (Sweden)

    Luft Karina

    2010-03-01

    Full Text Available Abstract Background High-throughput cultivations in microtiter plates are the method of choice to express proteins from recombinant clone libraries. Such processes typically include several steps, whereby some of them are linked by replication steps: transformation, plating, colony picking, preculture, main culture and induction. In this study, the effects of conventional replication methods and replication tools (8-channel pipette, 96-pin replicators: steel replicator with fixed or spring-loaded pins, plastic replicator with fixed pins on growth kinetics of Escherichia coli SCS1 pQE-30 pSE111 were observed. Growth was monitored with the BioLector, an on-line monitoring technique for microtiter plates. Furthermore, the influence of these effects on product formation of Escherichia coli pRhotHi-2-EcFbFP was investigated. Finally, a high-throughput cultivation process was simulated with Corynebacterium glutamicum pEKEx2-phoD-GFP, beginning at the colony picking step. Results Applying different replication tools and methods for one single strain resulted in high time differences of growth of the slowest and fastest growing culture. The shortest time difference (0.3 h was evaluated for the 96 cultures that were transferred with an 8-channel pipette from a thawed and mixed cryoculture and the longest time difference (6.9 h for cultures that were transferred with a steel replicator with fixed pins from a frozen cryoculture. The on-line monitoring of a simulated high-throughput cultivation process revealed strong variances in growth kinetics and a twofold difference in product formation. Another experiment showed that varying growth kinetics, caused by varying initial biomass concentrations (OD600 of 0.0125 to 0.2 led to strongly varying product formation upon induction at a defined point of time. Conclusions To improve the reproducibility of high-throughput cultivation processes and the comparability between different applied cultures, it is strongly

  3. A Rapid Filtration Sampling Probe for Fermentation Broth On-line Measurement%在线测量发酵液葡萄糖浓度的过滤取样探头的研制

    Institute of Scientific and Technical Information of China (English)

    高学金; 薛吉星; 张鹏; 王普

    2014-01-01

    设计了一种罐内快速过滤取样探头,以解决在线测量发酵参数过程中的发酵液连续取样问题。此探头由支撑体、旋塞阀、O 型圈、过滤膜管、管盖组成,可以直接插入发酵罐内,能够承受发酵前期的灭菌高温,并能避免取样时杂菌入侵发酵液。过滤膜采用筒状陶瓷膜,罐内发酵液经错流过滤,可由蠕动泵抽取适量无菌的渗透液给分析仪。利用此装置对葡萄糖溶液进行了取样测试,结果表明,此装置适用于发酵液在线取样,取样速率为3.0 mL/ min,葡萄糖透过率保持100%,探头引起的时间延迟约为2 min。%An inner-bioreactor rapid filtration sampling probe was designed to resolve the problems of continuous sampling the fermentation broth in on-line measurement the fermentation process. The probe consists of a support, a plug valve, an O-ring, a filter membrane and a pipe cover. It can be inserted directly into the bio-reactor withstanding high-temperature sterilization before fermentation, or preventing the bacteria's invasion during sampling. Fermentation broth in tank is cross-flow filtrated by a cylindrical ceramic membrane which is used as filtration membrane, and then the sterile permeated liquid is transported to the analyzer by a peristaltic pump. The sampling experiments using this device was described for sampling glucose solution indicating it is suitable for fermentation online sampling. The sampling rate is up to 3. 0 mL/ min, glucose permeability maintains 100% , and the delay time caused by the probe is about 2 min.

  4. Development of a simple extraction cell with bi-directional continuous flow coupled on-line to ICP-MS for assessment of elemental associations in solid samples

    DEFF Research Database (Denmark)

    Buanuam, Janya; Tiptanasup, Kasipa; Shiowatana, Juwadee

    2006-01-01

    A continuous-flow system comprising a novel, custom-built extraction module and hyphenated with inductively coupled plasma-mass spectrometric (ICP-MS) detection is proposed for assessing metal mobilities and geochemical associations in soil compartments as based on using the three step BCR (now...... to discretely introduce appropriate extract volumes to the detector at a given time and with a given dilution factor. The proposed hyphenated method demonstrates excellent performance for on-line monitoring of major and trace elements (Ca, Mn, Fe, Ni, Pb, Zn and Cd) released when applying the various extracting...... the extraction time. Thus, the intimate elemental association between Cd and Zn in contaminated soils could be assessed....

  5. Trace analysis of anions in organic matrices by ion chromatography coupled with a novel reversed-phase column for on-line sample pretreatment

    Institute of Scientific and Technical Information of China (English)

    Ying Ying Zhong; Wen Fang Zhou; Xue Ling Zeng; Ming Li Ye; Yan Zhu

    2011-01-01

    An ion chromatography (IC) system coupled with on-line column-switching technique was used to determine anions of μg/g levels in organic chemicals of analytical reagent grade. A novel polystyrene-divinylbenzene-carbon nanotube (PS-DVB-CNT) stationary phase was utilized for matrix elimination. A calibration study was conducted by preparing and analyzing eight concentrations (between 10 and 5000 μg/L) of eight standards in deionized water. The linearity was between 0.9978 and 1. And the detection limits ranged from 1.54 μg/L to 10.02 μg/L. A spiking study was performed on two representative organic chemicals. The recoveries were between 84.3% and 119.6%.

  6. NIR technology for on-line determination of superficial a(w) and moisture content during the drying process of fermented sausages.

    Science.gov (United States)

    Collell, Carles; Gou, Pere; Arnau, Jacint; Muñoz, Israel; Comaposada, Josep

    2012-12-01

    Three different NIR equipment were evaluated based on their ability to predict superficial water activity (a(w)) and moisture content in two types of fermented sausages (with and without moulds on surface), using partial least squares (PLS) regression models. The instruments differed mainly in wavelength range, resolution and measurement configuration. The most accurate equipment was used in a new experiment to achieve robust models in sausages with different salt contents and submitted to different drying conditions. The models developed showed determination coefficients (R(2)(P)) values of 0.990, 0.910 and 0.984, and RMSEP values of 1.560%, 0.220% and 0.007% for moisture, salt and a(w) respectively. It was demonstrated that NIR spectroscopy could be a suitable non-destructive method for on-line monitoring and control of the drying process in fermented sausages.

  7. Dynamic liquid-liquid-solid microextraction based on molecularly imprinted polymer filaments on-line coupling to high performance liquid chromatography for direct analysis of estrogens in complex samples.

    Science.gov (United States)

    Zhong, Qisheng; Hu, Yufei; Hu, Yuling; Li, Gongke

    2012-06-08

    A novel sample preparation technique termed dynamic liquid-liquid-solid microextraction (DLLSME) was developed and on-line coupled to high performance liquid chromatography (HPLC) for direct extraction, desorption, and analysis of trace estrogens in complex samples. The DLLSME consists of the aqueous donor phase, the organic medium phase and the molecularly imprinted polymer filaments (MIPFs) as solid acceptor phase. The organic solvent with lesser density was directly added on top of the aqueous sample, and the dynamic extraction was performed by circulating the organic solvent through the MIPFs inserted into a PEEK tube which served as an extraction and desorption chamber. Afterwards, the extracted analytes on the MIPFs were on-line desorbed and then introduced into the HPLC for analysis. To evaluate the feasibility of the on-line system, a new DLLSME-HPLC method was developed for the analysis of five estrogens in aqueous samples by using 17β-estradiol MIPFs as the solid phase. Under the optimized conditions, the enrichment factors of 51-70, limits of detection of 0.08-0.25 μg/L and precision within 4.5-6.9% were achieved. Furthermore, the proposed method was applied to the analysis of real samples including urine, milk and skin toner, satisfactory recovery (81.9-99.8%) and reproducibility (4.1-7.9%) were obtained. Especially, 0.59 μg/L of 17β-estradiol was determined in female urine sample. The DLLSME offers an attractive alternative for direct analysis of trace analytes in aqueous samples and could potentially be extended to other adsorptive materials.

  8. Multi-Sensor Distributive On-Line Processing, Visualization, and Analysis Infrastructure for an Agricultural Information System at the NASA Goddard Earth Sciences DAAC

    Science.gov (United States)

    Teng, William; Berrick, Steve; Leptuokh, Gregory; Liu, Zhong; Rui, Hualan; Pham, Long; Shen, Suhung; Zhu, Tong

    2004-01-01

    The Goddard Space Flight Center Earth Sciences Data and Information Services Center (GES DISC) Distributed Active Center (DAAC) is developing an Agricultural Information System (AIS), evolved from an existing TRMM On-line Visualization and Analysis System precipitation and other satellite data products and services. AIS outputs will be ,integrated into existing operational decision support system for global crop monitoring, such as that of the U.N. World Food Program. The ability to use the raw data stored in the GES DAAC archives is highly dependent on having a detailed understanding of the data's internal structure and physical implementation. To gain this understanding is a time-consuming process and not a productive investment of the user's time. This is an especially difficult challenge when users need to deal with multi-sensor data that usually are of different structures and resolutions. The AIS has taken a major step towards meeting this challenge by incorporating an underlying infrastructure, called the GES-DISC Interactive Online Visualization and Analysis Infrastructure or "Giovanni," that integrates various components to support web interfaces that ,allow users to perform interactive analysis on-line without downloading any data. Several instances of the Giovanni-based interface have been or are being created to serve users of TRMM precipitation, MODIS aerosol, and SeaWiFS ocean color data, as well as agricultural applications users. Giovanni-based interfaces are simple to use but powerful. The user selects geophysical ,parameters, area of interest, and time period; and the system generates an output ,on screen in a matter of seconds.

  9. Optimum yields of dibenzylbutyrolactone-type lignans from Cynareae fruits, during their ripening, germination and enzymatic hydrolysis processes, determined by on-line chromatographic methods.

    Science.gov (United States)

    Szokol-Borsodi, Lilla; Sólyomváry, Anna; Molnár-Perl, Ibolya; Boldizsár, Imre

    2012-01-01

    Dibenzylbutyrolactone-type lignans are the physiologically active constituents of the achene fruits of Cynareae. These lignans occur in glycoside/aglycone forms: in the highest quantity of the arctiin/arctigenin, matairesinoside/matairesinol and tracheloside/trachelogenin pairs found in the fruits of Arctium lappa L., Centaurea scabiosa L. and Cirsium arvense (L.) Scop. To optimise the extraction yield of the arctiin/arctigenin, matairesinoside/matairesinol and tracheloside/trachelogenin glycoside/aglycone pairs, from the fruits of Arctium lappa, Centaurea scabiosa and Cirsium arvense, under the ripening, germination and enzymatic hydrolysis processes of the fruits. Identification and quantification of lignans were performed with on-line gas chromatography-mass spectrometry (GC-MS) and with high performance liquid chromatography (HPLC), both with UV and mass selective detections (HPLC-UV/MS). As novelties to the field it was confirmed that: (i) the unripe fruits provide a high amount of lignans, similar to the ripe fruit; (ii) the fruits of Arctium lappa and Cirsium arvense do have glycosidase activity to hydrolyse their lignan glycosides into free lignans; (iii) the glycosidase of Centaurea scabiosa fruit becomes activated under its germination process only; and (iv) the overwhelming part of the fruits lignan contents (80-94%) in all three species are accumulated in the embryo. The best sources of (i) lignan aglycones are the enzyme-hydrolysed embryos, separating spontaneously during the germination process, and (ii) lignan glycosides are the unripe fruits. Copyright © 2012 John Wiley & Sons, Ltd.

  10. Design and development of a miniaturised total chemical analysis system for on-line lactate and glucose monitoring in biological samples

    NARCIS (Netherlands)

    Dempsey, Eithne; Diamond, Dermot; Smyth, Malcolm R.; Urban, Gerald; Jobst, Gerhard; Moser, Isabella; Verpoorte, Elisabeth M.J.; Manz, Andreas; Widmer, H. Michael; Rabenstein, Kai; Freaney, Rosemarie

    1997-01-01

    A miniaturised Total chemical Analysis System (μTAS) for glucose and lactate measurement in biological samples constructed based on an integrated microdialysis sampling and detection system. The complete system incorporates a microdialysis probe for intravascular monitoring in an ex vivo mini-shunt

  11. High throughput sample processing and automated scoring

    Directory of Open Access Journals (Sweden)

    Gunnar eBrunborg

    2014-10-01

    Full Text Available The comet assay is a sensitive and versatile method for assessing DNA damage in cells. In the traditional version of the assay, there are many manual steps involved and few samples can be treated in one experiment. High throughput modifications have been developed during recent years, and they are reviewed and discussed. These modifications include accelerated scoring of comets; other important elements that have been studied and adapted to high throughput are cultivation and manipulation of cells or tissues before and after exposure, and freezing of treated samples until comet analysis and scoring. High throughput methods save time and money but they are useful also for other reasons: large-scale experiments may be performed which are otherwise not practicable (e.g., analysis of many organs from exposed animals, and human biomonitoring studies, and automation gives more uniform sample treatment and less dependence on operator performance. The high throughput modifications now available vary largely in their versatility, capacity, complexity and costs. The bottleneck for further increase of throughput appears to be the scoring.

  12. Metrology Sampling Strategies for Process Monitoring Applications

    KAUST Repository

    Vincent, Tyrone L.

    2011-11-01

    Shrinking process windows in very large scale integration semiconductor manufacturing have already necessitated the development of control systems capable of addressing sub-lot-level variation. Within-wafer control is the next milestone in the evolution of advanced process control from lot-based and wafer-based control. In order to adequately comprehend and control within-wafer spatial variation, inline measurements must be performed at multiple locations across the wafer. At the same time, economic pressures prompt a reduction in metrology, for both capital and cycle-time reasons. This paper explores the use of modeling and minimum-variance prediction as a method to select the sites for measurement on each wafer. The models are developed using the standard statistical tools of principle component analysis and canonical correlation analysis. The proposed selection method is validated using real manufacturing data, and results indicate that it is possible to significantly reduce the number of measurements with little loss in the information obtained for the process control systems. © 2011 IEEE.

  13. Sequential-injection on-line preconcentration using chitosan resin functionalized with 2-amino-5-hydroxy benzoic acid for the determination of trace elements in environmental water samples by inductively coupled plasma-atomic emission spectrometry.

    Science.gov (United States)

    Sabarudin, Akhmad; Lenghor, Narong; Oshima, Mitsuko; Hakim, Lukman; Takayanagi, Toshio; Gao, Yun-Hua; Motomizu, Shoji

    2007-07-31

    A new chelating resin using chitosan as a base material was synthesized. Functional moiety of 2-amino-5-hydroxy benzoic acid (AHBA) was chemically bonded to the amino group of cross-linked chitosan (CCTS) through the arm of chloromethyloxirane (CCTS-AHBA resin). Several elements, such as Ag, Be, Cd, Co, Cu, Ni, Pb, U, V, and rare earth elements (REEs), could be adsorbed on the resin. To use the resin for on-line pretreatment, the resin was packed in a mini-column and installed into a sequential-injection/automated pretreatment system (Auto-Pret System) coupled with inductively coupled plasma-atomic emission spectrometry (ICP-AES). The sequential-injection/automated pretreatment system was a laboratory-assembled, and the program was written using Visual Basic software. This system can provide easy operation procedures, less reagent consumption, as well as less waste production. Experimental variables considered as effective factors in the improvement sensitivity, such as an eluent concentration, a sample and an eluent flow rate, pH of samples, and air-sandwiched eluent were carefully optimized. The proposed system provides excellent on-line collection efficiency, as well as high concentration factors of analytes in water samples, which results in highly sensitive detection of ultra-trace and trace analysis. Under the optimal conditions, the detection limits of 24 elements examined are in the range from ppt to sub-ppb levels. The proposed method was validated by using the standard reference material of a river water, SLRS-4, and the applicability was further demonstrated to the on-line collection/concentration of trace elements, such as Ag, Be, Cd, Co, Cu, Ni, Pb, U, V, and REEs in water samples.

  14. On-line restricted access molecularly imprinted solid phase extraction of ivermectin in meat samples followed by HPLC-UV analysis.

    Science.gov (United States)

    de Lima, Marcela Marília; Vieira, André Coutinho; Martins, Isarita; Boralli, Vanessa Bergamin; Borges, Keyller Bastos; Figueiredo, Eduardo Costa

    2016-04-15

    A new restricted access molecularly imprinted polymer coated with bovine serum albumin (RAMIP-BSA) was synthesized, characterized and used for direct analysis of ivermectin from bovine meat samples, in a two-dimensional liquid chromatography system with UV detection. Ivermectin, 4-vynilpiridine and ethylene glycol dimethacrylate were employed as template, functional monomer and cross-linker, respectively. A BSA layer was cross-linked around the polymer, resulting in a biocompatible chemical barrier able to eliminate about 100% of protein from the samples. Ivermectin was extracted from the minced meat samples through a solvent extraction using methanol:water (70:30, v:v), and the extracts were directly injected into the two-dimensional liquid chromatography system, without any other treatment. Samples, fortified with ivermectin from 50 to 500 μg kg(-1), were used to build the analytical calibration curve (r=0.996). The limit of quantification was 50 μg kg(-1). Precision and accuracy presented variation coefficients, as well as relative errors lower than 17.0% and within -18.5% and 22.0%, respectively.

  15. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    as substitutes for labor-intensive, manual, sample-pre-treatment and/or solution-handling procedures prior to analyte detection by inductively coupled plasma mass spectrometry (ICP-MS). The present review presents and discusses the progress of the state of the art in implementing miniaturized FI/SI systems...

  16. On-Line Hydrogen-Isotope Measurements of Organic Samples Using Elemental Chromium : An Extension for High Temperature Elemental-Analyzer Techniques

    NARCIS (Netherlands)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B.; Meijer, Harro A. J.; Brand, Willi A.; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-rati

  17. On-line simultaneous and rapid separation of anions and cations from a single sample using dual-capillary sequential injection-capillary electrophoresis.

    Science.gov (United States)

    Gaudry, Adam J; Guijt, Rosanne M; Macka, Mirek; Hutchinson, Joseph P; Johns, Cameron; Hilder, Emily F; Dicinoski, Greg W; Nesterenko, Pavel N; Haddad, Paul R; Breadmore, Michael C

    2013-06-05

    A novel capillary electrophoresis (CE) approach has been developed for the simultaneous rapid separation and identification of common environmental inorganic anions and cations from a single sample injection. The method utilised a sequential injection-capillary electrophoresis instrument (SI-CE) with capacitively-coupled contactless conductivity detection (C(4)D) constructed in-house from commercial-off-the-shelf components. Oppositely charged analytes from a single sample plug were simultaneously injected electrokinetically onto two separate capillaries for independent separation and detection. Injection was automated and may occur from a syringe or be directly coupled to an external source in a continuous manner. Software control enabled high sample throughput (17 runs per hour for the target analyte set) and the inclusion of an isolation valve allowed the separation capillaries to be flushed, increasing throughput by removing slow migrating species as well as improving repeatability. Various environmental and industrial samples (subjected only to filtering) were analysed in the laboratory with a 3 min analysis time which allowed the separation of 23 inorganic and small organic anions and cations. Finally, the system was applied to an extended automated analysis of Hobart Southern Water tap water for a period of 48 h. The overall repeatability of the migration times of a 14 analyte standard sample was less than 0.74% under laboratory conditions. LODs ranged from 5 to 61 μg L(-1). The combination of automation, high confidence of peak identification, and low limits of detection make this a useful system for the simultaneous identification of a range of common inorganic anions and cations for discrete or continuous monitoring applications.

  18. Simultaneous speciation of inorganic arsenic and antimony in water samples by hydride generation-double channel atomic fluorescence spectrometry with on-line solid-phase extraction using single-walled carbon nanotubes micro-column

    Energy Technology Data Exchange (ETDEWEB)

    Wu Hong, E-mail: wuhong1968@hotmail.com; Wang Xuecui; Liu Bing; Liu Yueling; Li Shanshan; Lu Jusheng; Tian Jiuying; Zhao Wenfeng; Yang Zonghui

    2011-01-15

    A new method was developed for the simultaneous speciation of inorganic arsenic and antimony in water by on-line solid-phase extraction coupled with hydride generation-double channel atomic fluorescence spectrometry (HG-DC-AFS). The speciation scheme involved the on-line formation and retention of the ammonium pyrrolidine dithiocarbamate complexes of As(III) and Sb(III) on a single-walled carbon nanotubes packed micro-column, followed by on-line elution and simultaneous detection of As(III) and Sb(III) by HG-DC-AFS; the total As and total Sb were determined by the same protocol after As(V) and Sb(V) were reduced by thiourea, with As(V) and Sb(V) concentrations obtained by subtraction. Various experimental parameters affecting the on-line solid-phase extraction and determination of the analytes species have been investigated in detail. With 180 s preconcentration time, the enrichment factors were found to be 25.4 for As(III) and 24.6 for Sb(III), with the limits of detection (LODs) of 3.8 ng L{sup -1} for As(III) and 2.1 ng L{sup -1} for Sb(III). The precisions (RSD) for five replicate measurements of 0.5 {mu}g L{sup -1} of As(III) and 0.2 {mu}g L{sup -1} of Sb(III) were 4.2 and 4.8%, respectively. The developed method was validated by the analysis of standard reference materials (NIST SRM 1640a), and was applied to the speciation of inorganic As and Sb in natural water samples.

  19. Application of off/on line sequential injection system with high resolution ICP-MS to measurement radionuclides in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Chang-Kyu Kim (IAEA, Physics, Chemistry and Instrumentation Lab., Agency' s Laboratories, Seibersdorf (Austria))

    2010-03-15

    A sequential injection system was developed, which can be widely used for the separation and preconcentration of analytes from diverse environmental samples. The system enables the separation time to be shortened by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in a chromatographic column. The SI system was successfully applied to the separation of 237Np and Pu isotopes in IAEA reference materials and environmental samples, and to the sequential separation of 210Po and 210Pb in a phosphogypsum candidate reference material. The replicate analysis results of 237Np, 239+240Pu 210Po and 210Pb in some IAEA reference materials using the SI system associated with HR-ICP-MS, alpha-spectrometry and LSC are in good agreement with the recommended value within 5% of standard deviation. The SI system enabled a halving of the separation time required for radionuclides. (author)

  20. Rapid Screening of Carboxylic Acids from Waste and Surface Waters by ESI-MS/MS Using Barium Ion Chemistry and On-Line Membrane Sampling.

    Science.gov (United States)

    Duncan, Kyle D; Volmer, Dietrich A; Gill, Chris G; Krogh, Erik T

    2016-03-01

    Negative ion tandem mass spectrometric analysis of aliphatic carboxylic acids often yields only non-diagnostic ([M - H](-)) ions with limited selective fragmentation. However, carboxylates cationized with Ba(2+) have demonstrated efficient dissociation in positive ion mode, providing structurally diagnostic product ions. We report the application of barium adducts followed by collision induced dissociation (CID), to improve selectivity for rapid screening of carboxylic acids in complex aqueous samples. The quantitative MS/MS method presented utilizes common product ions of [M - H + Ba](+) precursor ions. The mechanism of product ion formation is investigated using isotopically labeled standards and a series of structurally related carboxylic acids. The results suggest that hydrogen atoms in the β and γ positions yield common product ions ([BaH](+) and [BaOH](+)). Furthermore, the diagnostic product ion at m/z 196 serves as a qualifying ion for carboxylate species. This methodology has been successfully used in conjunction with condensed phase membrane introduction mass spectrometry (CP-MIMS), with barium acetate added directly to the methanol acceptor phase. The combination enables rapid screening of carboxylic acids directly from acidified water samples (wastewater effluent, spiked natural waters) using a capillary hollow fiber PDMS membrane immersion probe. We have applied this technique for the direct analysis of complex naphthenic acid mixtures spiked into natural surface waters using CP-MIMS. Selectivity at the ionization and tandem mass spectrometry level eliminate isobaric interferences from hydroxylated species present within the samples, which have been observed in negative electrospray ionization.

  1. Rapid Screening of Carboxylic Acids from Waste and Surface Waters by ESI-MS/MS Using Barium Ion Chemistry and On-Line Membrane Sampling

    Science.gov (United States)

    Duncan, Kyle D.; Volmer, Dietrich A.; Gill, Chris G.; Krogh, Erik T.

    2016-03-01

    Negative ion tandem mass spectrometric analysis of aliphatic carboxylic acids often yields only non-diagnostic ([M - H]-) ions with limited selective fragmentation. However, carboxylates cationized with Ba2+ have demonstrated efficient dissociation in positive ion mode, providing structurally diagnostic product ions. We report the application of barium adducts followed by collision induced dissociation (CID), to improve selectivity for rapid screening of carboxylic acids in complex aqueous samples. The quantitative MS/MS method presented utilizes common product ions of [M - H + Ba]+ precursor ions. The mechanism of product ion formation is investigated using isotopically labeled standards and a series of structurally related carboxylic acids. The results suggest that hydrogen atoms in the β and γ positions yield common product ions ([BaH]+ and [BaOH]+). Furthermore, the diagnostic product ion at m/z 196 serves as a qualifying ion for carboxylate species. This methodology has been successfully used in conjunction with condensed phase membrane introduction mass spectrometry (CP-MIMS), with barium acetate added directly to the methanol acceptor phase. The combination enables rapid screening of carboxylic acids directly from acidified water samples (wastewater effluent, spiked natural waters) using a capillary hollow fiber PDMS membrane immersion probe. We have applied this technique for the direct analysis of complex naphthenic acid mixtures spiked into natural surface waters using CP-MIMS. Selectivity at the ionization and tandem mass spectrometry level eliminate isobaric interferences from hydroxylated species present within the samples, which have been observed in negative electrospray ionization.

  2. Coupling on-line preconcentration by ion-exchange with ETAAS. A novel flow injection approach based on the use of a renewable microcolumn as demonstrated for the determination of nickel in environmental and biological samples

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2000-01-01

    A novel way of exploiting flow injection/sequential injection (FIA/SIA) on-line ion-exchange preconcentration with detection by electrothermal atomic absorption spectrometry (ETAAS) is described and demonstrated for the determination of trace-levels of nickel. Based on the use of a renewable...... microcolumn incorporated within an integrated micro FI-system, the column is loaded with a defined volume of small beads of an SP Sephadex C-25 cation-exchange resin and subsequently exposed to a metered amount of sample solution. However, instead of eluting the retained analyte from the organic ion-exchange...

  3. Development of molecular imprinted column-on line-two dimensional liquid chromatography for selective determination of clenbuterol residues in biological samples.

    Science.gov (United States)

    Guo, Pengqi; Luo, Zhimin; Xu, Xinya; Zhou, Yulan; Zhang, Bilin; Chang, Ruimiao; Du, Wei; Chang, Chun; Fu, Qiang

    2017-02-15

    A novel method coupling molecular imprinted monolithic column with two-dimensional liquid chromatography was developed and validated for the analysis of clenbuterol in pork liver and swine urine samples. The polymers were characterized by using Fourier transform infrared spectroscopy, nitrogen adsorption desorption analyses, frontal analysis and the adsorption of selectivity. The results indicated that the imprinted columns were well prepared and possessed high selectivity adsorption capacity. Subsequently, the MIMC-2D-LC (molecular imprinted monolithic column-two dimensional liquid chromatography) method was developed for the selective analysis of clenbuterol in practical samples. The accuracy ranged from 94.3% to 99.7% and from 93.7% to 99.6% for liver and urine, respectively. The relative standard deviation (RSD) of repeatability was lower than 8.6% for both analyses. The limit of detections was 16ng·mL(-1) for liver and 25ng·mL(-1) for urine, respectively. Compared with the reported methods, the disturbance of endogenous impurity could be avoided by the 2D-LC method.

  4. On-line capillary electrophoresis enrichment by combining chitosan trapping with surfactant assisted sample stacking for the ultratrace determination of organic acids in Plateau alfalfa roots.

    Science.gov (United States)

    Li, Xi; Ju, Yuyun; Xu, Yinyin; Wang, Weifeng; Dong, Yalei; Ma, Yanhua; Chen, Xingguo

    2013-07-30

    In this paper, four organic acids constituents of Plateau alfalfa roots have been identified and detected by a novel capillary electrophoresis (CE) strategy which combined chitosan (CS) trapping and cetyltrimethyl ammonium bromide (CTAB) assisted sample stacking. Under the optimized condition, organic acids, i.e., aconitic acid, gallic acid, citric acid and l-malic acid were concentrated and separated within 3 min. Validation parameters of this method (such as detection limits, linearity and precision) were also investigated and the limit of detection (LOD) was 2.41-53.9 ng mL(-1). Linearity was obtained over the magnitude range of 5-4000 ng mL(-1) approximately for different organic acids and 3×10(2)-1.5×10(4) folds enrichment was achieved. The method has been applied to the determination of organic acids in roots of normal grown Plateau alfalfa and stressing affected Plateau alfalfa. Satisfactory results and recoveries were obtained in the analysis without costly and complicated sample pretreatment.

  5. An on-line spectrophotometric determination of trace amounts of thiourea in tap water, orange juice, and orange peel samples using multi-channel flow injection analysis.

    Science.gov (United States)

    Arab Chamjangali, M; Goudarzi, N; Ghochani Moghadam, A; Amin, A H

    2015-01-01

    In this work, a flow injection analysis (FIA) method was introduced for the determination of trace amounts of thiourea in tap water. This method is based upon the inhibition effect of thiourea on the reaction between meta-cresol purple (MCP) and potassium bromate catalyzed by bromide ions in a sulfuric acid medium. In the presence of thiourea, an induction period appears in the reaction system, and as a result, the absorbance of MCP increases at 525 nm in the FIA manifold. The chemical and FIA variables are studied and optimized using the univariate and Simplex optimization methods. Under the optimum conditions, thiourea can be determined in the range of 0.100-13.0 μg mL(-1). The limit of detection (3σ) for thiourea was found to be 0.0310 μg mL(-1). The relative standard deviations (RSDs) for six replicate determinations of 0.500, 5.00, and 12.0 μg mL(-1) of thiourea were 4.0%, 1.8%, and 1.2%, respectively. The proposed method was also applied for the determination of thiourea in orange juice and orange peel samples with recoveries in the range of 98.0-101%. The analytical speed of the method was calculated to be about 120 sample per hour.

  6. On-Line Organic Solvent Field Enhanced Sample Injection in Capillary Zone Electrophoresis for Analysis of Quetiapine in Beagle Dog Plasma.

    Science.gov (United States)

    Cao, Yuqing; Wen, Jun; Zhou, Tingting; Fan, Guorong

    2016-01-21

    A rapid and sensitive capillary zone electrophoresis (CZE) method with field enhanced sample injection (FESI) was developed and validated for the determination of quetiapine fumarate in beagle dog plasma, with a sample pretreatment by LLE in 96-well deep format plate. The optimum separation was carried out in an uncoated 31.2 cm × 75 μm fused-silica capillary with an applied voltage of 13 kV. The electrophoretic analysis was performed by 50 mM phosphate at pH 2.5. The detection wavelength was 210 nm. Under these optimized conditions, FESI with acetonitrile enhanced the sensitivity of quetiapine about 40-50 folds in total. The method was suitably validated with respect to stability, specificity, linearity, lower limit of quantitation, accuracy, precision and extraction recovery. Using mirtazapine as an internal standard (100 ng/mL), the response of quetiapine was linear over the range of 1-1000 ng/mL. The lower limit of quantification was 1 ng/mL. The intra- and inter-day precisions for the assay were within 4.8% and 12.7%, respectively. The method represents the first application of FESI-CZE to the analysis of quetiapine fumarate in beagle dog plasma after oral administration.

  7. On-Line Organic Solvent Field Enhanced Sample Injection in Capillary Zone Electrophoresis for Analysis of Quetiapine in Beagle Dog Plasma

    Directory of Open Access Journals (Sweden)

    Yuqing Cao

    2016-01-01

    Full Text Available A rapid and sensitive capillary zone electrophoresis (CZE method with field enhanced sample injection (FESI was developed and validated for the determination of quetiapine fumarate in beagle dog plasma, with a sample pretreatment by LLE in 96-well deep format plate. The optimum separation was carried out in an uncoated 31.2 cm × 75 μm fused-silica capillary with an applied voltage of 13 kV. The electrophoretic analysis was performed by 50 mM phosphate at pH 2.5. The detection wavelength was 210 nm. Under these optimized conditions, FESI with acetonitrile enhanced the sensitivity of quetiapine about 40–50 folds in total. The method was suitably validated with respect to stability, specificity, linearity, lower limit of quantitation, accuracy, precision and extraction recovery. Using mirtazapine as an internal standard (100 ng/mL, the response of quetiapine was linear over the range of 1–1000 ng/mL. The lower limit of quantification was 1 ng/mL. The intra- and inter-day precisions for the assay were within 4.8% and 12.7%, respectively. The method represents the first application of FESI-CZE to the analysis of quetiapine fumarate in beagle dog plasma after oral administration.

  8. On-line preconcentration of ultra-trace thallium(I in water samples with titanium dioxide nanoparticles and determination by graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Saeid Asadpour

    2016-11-01

    Full Text Available A new method has been developed for the determination of Tl(I based on simultaneous sorption and preconcentration with a microcolumn packed with TiO2 nanoparticle with a high specific surface area prepared by Sonochemical synthesis prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS. The optimum experimental parameters for preconcentration of thallium, such as elution condition, pH, and sample volume and flow rate have been investigated. Tl(I can be quantitatively retained by TiO2 nanoparticles at pH 9.0, then eluted completely with 1.0 mol L−1 HCl. The adsorption capacity of TiO2 nanoparticles for Tl(I was found to be 25 mg g−1. Also detection limit, precision (RSD, n = 8 and enrichment factor for Tl(I were 87 ng L−1, 6.4% and 100, respectively. The method has been applied for the determination of trace amounts of Tl(I in some environmental water samples with satisfactory results.

  9. Grafting 3-mercaptopropyl trimethoxysilane on multi-walled carbon nanotubes surface for improving on-line cadmium(II) preconcentration from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Corazza, Marcela Zanetti; Somera, Bruna Fabrin; Segatelli, Mariana Gava [Departamento de Quimica, Universidade Estadual de Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Campus Universitario, Londrina-PR, CEP 86051-990 (Brazil); Tarley, Cesar Ricardo Teixeira, E-mail: tarley@uel.br [Departamento de Quimica, Universidade Estadual de Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Campus Universitario, Londrina-PR, CEP 86051-990 (Brazil); Instituto Nacional de Ciencia e Tecnologia (INCT) de Bioanalitica, Universidade Estadual de Campinas (UNICAMP), Instituto de Quimica, Departamento de Quimica Analitica, Cidade Universitaria Zeferino, Vaz, s/n, CEP 13083-970, Campinas-SP (Brazil)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer 3-Mercaptopropyl trimethoxysilane grafted on MWCNT surface was prepared. Black-Right-Pointing-Pointer The material promoted an increase on performance of MWCNT for Cd{sup 2+} adsorption. Black-Right-Pointing-Pointer The life time of adsorbent was very high. Black-Right-Pointing-Pointer An improvement of 84% on the sensitivity was achieved. - Abstract: In the present study, the performance of multi-walled carbon nanotubes (MWCNTs) grafted with 3-mercaptopropyltrimethoxysilane (3-MPTMS), used as a solid phase extractor for Cd{sup 2+} preconcentration in a flow injection system coupled to flame atomic absorption spectrometry (FAAS), was evaluated. The procedure involved the preconcentration of 20.0 mL of Cd{sup 2+} solution at pH 7.5 (0.1 mol L{sup -1} buffer phosphate) through 70 mg of 3-MPTMS-grafted MWCNTs packed into a minicolumn at 6.0 mL min{sup -1}. The elution step was carried out with 1.0 mol L{sup -1} HCl. Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to estimate the extent of the MWCNT chemical modification. The 3-MPTMS-grafted MWCNTs provided a 1.68 times improvement in the sensitivity of the Cd{sup 2+} FAAS determination compared to the unsilanized oxidized MWCNTs. The following parameters were obtained: preconcentration factor of 31.5, consumptive index of 0.635 mL, sample throughput of 14 h{sup -1}, and concentration efficiency of 9.46 min{sup -1}. The analytical curve was constructed in the range of 1.0-60.0 {mu}g L{sup -1} (r = 0.9988), and the detection and quantification limits were found to be 0.15 {mu}g L{sup -1} and 0.62 {mu}g L{sup -1}, respectively. Different types of water samples and cigarette sample were successfully analyzed, and the results were compared using electrothermal atomic absorption spectrometry (ETAAS) as reference technique. In addition, the accuracy of proposed method was also checked by analysis of

  10. Simple and Excellent Selective Chemiluminescence-Based CS2 On-Line Detection System for Rapid Analysis of Sulfur-Containing Compounds in Complex Samples.

    Science.gov (United States)

    Zhang, Runkun; Li, Gongke; Hu, Yufei

    2015-06-02

    To study the interesting chemical reaction phenomenon can greatly contribute to the development of an innovative analytical method. In this paper, a simple CL reaction cell was constructed to study the chemiluminescence (CL) emission from the thermal oxidation of carbon disulfide (CS2). We found that the CL detection of CS2 exhibits unique characteristics of excellent selectivity and rapid response capacity. Experimental investigations together with theoretical calculation were performed to study the mechanism behind the CL reaction. The results revealed that the main luminous intermediates generated during the thermal degradation of CS2 are SO2* and CO2*. Significantly, this CL emission phenomenon has a wide application due to many sulfur-containing compounds that can convert to CS2 under special conditions. On the basis of this scheme, a CS2-generating and detection system was developed for rapid measurement of CS2 or other compounds that can convert to CS2. The usefulness of the system was demonstrated by measuring dithiocarbamate (DTC) pesticides (selected mancozeb as a representative analyte) based on the evolution of CS2 in spiked agricultural products. Results showed that the system allows online and large volume detection of CS2 under nonequilibrium condition, which greatly reduces the analytical time. The concentrations of mancozeb in the spiked samples were well-quantified with satisfied recoveries of 76.9-97.3%. The system not only addresses the urgent need for rapid in-field screening of DTC residues in foodstuffs but also opens a new opportunity for the fast, convenient, and cost-effective detection of CS2 and some other sulfur-containing compounds in complex samples.

  11. A fully automated and fast method using direct sample injection combined with fused-core column on-line SPE-HPLC for determination of ochratoxin A and citrinin in lager beers.

    Science.gov (United States)

    Lhotská, Ivona; Šatínský, Dalibor; Havlíková, Lucie; Solich, Petr

    2016-05-01

    A new fast and sensitive method based on on-line solid-phase extraction on a fused-core precolumn coupled to liquid chromatography with fluorescence detection has been developed for ochratoxin A (OTA) and citrinin (CIT) determination in lager beer samples. Direct injection of 100 μL filtered beer samples into an on-line SPE-HPLC system enabled fast and effective sample extraction including separation in less than 6 min. Preconcentration of OTA and CIT from beer samples was performed on an Ascentis Express RP C18 guard column (5 × 4.6 mm), particle size 2.7 μm, with a mobile phase of methanol/0.5% aqueous acetic acid pH 2.8 (30:70, v/v) at a flow rate of 2.0 mL min(-1). The flow switch from extraction column to analytical column in back-flush mode was set at 2.0 min and the separation was performed on the fused-core column Ascentis Express Phenyl-Hexyl (100 × 4.6 mm), particle size 2.7 μm, with a mobile phase acetonitrile/0.5% aqueous acetic acid pH 2.8 in a gradient elution at a flow rate of 1.0 mL min(-1) and temperature of 50 °C. Fluorescence excitation/emission detection wavelengths were set at 335/497 nm. The accuracy of the method, defined as the mean recoveries of OTA and CIT from light and dark beer samples, was in the range 98.3-102.1%. The method showed high sensitivity owing to on-line preconcentration; LOQ values were found to be 10 and 20 ng L(-1) for OTA and CIT, respectively. The found values of OTA and CIT in all tested light, dark and wheat beer samples were significantly below the maximum tolerable limits (3.0 μg kg(-1) for OTA and 2000 μg kg(-1) for CIT) set by the European Union.

  12. Special filter samples of Hanford process effluent gases

    Energy Technology Data Exchange (ETDEWEB)

    Soldat, J.K.

    1957-01-22

    This document contains information on special filter samples of Hanford Process Effluent Gases. The filters are identified by code numbers only. Included in this paper are tables explaining the sample code numbers, sampling locations, and process conditions during sampling. Also included, is a copy of the monthly and quarterly average results for Regional Monitoring's routine stack program for the fourth quarter of 1956.

  13. Multi-Sensor Distributive On-line Processing, Visualization, and Analysis Infrastructure for an Agricultural Information System at the NASA Goddard Earth Sciences DAAC

    Science.gov (United States)

    Teng, W.; Berrick, S.; Leptoukh, G.; Liu, Z.; Rui, H.; Pham, L.; Shen, S.; Zhu, T.

    2004-12-01

    The Goddard Space Flight Center Earth Sciences Data and Information Services Center (GES DISC) Distributed Active Archive Center (DAAC) is developing an Agricultural Information System (AIS), evolved from an existing TRMM Online Visualization and Analysis System (TOVAS), which will operationally provide precipitation and other satellite data products and services. AIS outputs will be integrated into existing operational decision support systems for global crop monitoring, such as that of the U.N. World Food Program. The ability to use the raw data stored in the GES DAAC archives is highly dependent on having a detailed understanding of the data's internal structure and physical implementation. To gain this understanding is a time-consuming process and not a productive investment of the user's time. This is an especially difficult challenge when users need to deal with multi-sensor data that usually are of different structures and resolutions. The AIS has taken a major step towards meeting this challenge by incorporating an underlying infrastructure, called the GES-DISC Interactive Online Visualization and Analysis Infrastructure or "Giovanni," that integrates various components to support web interfaces that allow users to perform interactive analysis on-line without downloading any data. Several instances of the Giovanni-based interface have been or are being created to serve users of TRMM precipitation, MODIS aerosol, and SeaWiFS ocean color data, as well as agricultural applications users. Giovanni-based interfaces are simple to use but powerful. The user selects geophysical parameters, area of interest, and time period; and the system generates an output on screen in a matter of seconds. The currently available output options are (1) area plot - averaged or accumulated over any available data period for any rectangular area; (2) time plot - time series averaged over any rectangular area; (3) Hovmoller plots - longitude-time and latitude-time plots; (4) ASCII

  14. Controle on-line da taxa média de defeitos por item produzido numa produção finita on-line process control of the average number of defects per item in a short run production

    Directory of Open Access Journals (Sweden)

    Carla Simone de Lima Teixeira

    2013-01-01

    Markov chain is used to determine the transitory probabilities, which will be considered in terms of cost, to determine the optimal strategy for monitoring, obtained by optimizing three parameters: sampling interval (m, retrospective sample size (r, and control limit (cl. These parameters are obtained computationally by direct search to minimize the expression of the average cost per item produced. A numerical example illustrates the proposal.

  15. On-line Estimation of Biomass in Fermentation Process Using Support Vector Machine%基于支持向量机的发酵过程生物量在线估计

    Institute of Scientific and Technical Information of China (English)

    王建林; 于涛; 金翠云

    2006-01-01

    Biomass is a key factor in fermentation process, directly influencing the performance of the fermentation system as well as the quality and yield of the targeted product. Therefore, the on-line estimation of biomass is indispensable. The soft-sensor based on support vector machine (SVM) for an on-line biomass estimation was analyzed in detail, and the improved SVM called the weighted least squares support vector machine was presented to follow the dynamic feature of fermentation process. The model based on the modified SVM was developed and demonstrated using simulation experiments.

  16. On-line chemical composition analyzer development

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, M.J.; Garrison, A.A.; Muly, E.C.; Moore, C.F.

    1992-02-01

    The energy consumed in distillation processes in the United States represents nearly three percent of the total national energy consumption. If effective control of distillation columns can be accomplished, it has been estimated that it would result in a reduction in the national energy consumption of 0.3%. Real-time control based on mixture composition could achieve these savings. However, the major distillation processes represent diverse applications and at present there does not exist a proven on-line chemical composition sensor technology which can be used to control these diverse processes in real-time. This report presents a summary of the findings of the second phase of a three phase effort undertaken to develop an on-line real-time measurement and control system utilizing Raman spectroscopy. A prototype instrument system has been constructed utilizing a Perkin Elmer 1700 Spectrometer, a diode pumped YAG laser, two three axis positioning systems, a process sample cell land a personal computer. This system has been successfully tested using industrially supplied process samples to establish its performance. Also, continued application development was undertaken during this Phase of the program using both the spontaneous Raman and Surface-enhanced Raman modes of operation. The study was performed for the US Department of Energy, Office of Industrial Technologies, whose mission is to conduct cost-shared R D for new high-risk, high-payoff industrial energy conservation technologies. Although this document contains references to individual manufacturers and their products, the opinions expressed on the products reported do not necessarily reflect the position of the Department of Energy.

  17. PROCESS MODELLING OF ROCK SAMPLE HANDLING IN PETROPHYSICAL LABORATORY

    Directory of Open Access Journals (Sweden)

    Adaleta Perković

    2010-12-01

    Full Text Available Everyday procedures carried out in petrophysical laboratory can be defined as a complete cycle of business processes. Sample handling process is one of the most significant and demanding procedures. It starts with sample receiving in laboratory and then subsequently, series of analyses and measurements are carrying out resulting in petrophysical parameters. Sample handling process ends with sample storage and archiving of obtained measurement data. Process model is used for description of repeating activities. Sample handling process is presented by graphical method and use of eEPC diagram (extended Event-Driven Process Chain which describe process based on events. Created process model jointly binds static laboratory resources (measuring instruments, computers and data, speeds up process with increasing the user’s efficiency and with improvements of data and information exchange. Besides flow of activity, model of data sample handling includes information about system components (laboratory equipment and software applications that carry out activities. Described model, with minor modifications and adaptations, can be used in any laboratory that is dealing with samples (the paper is published in Croatian.

  18. A study on sampling strategies in the figure cognitive process

    Institute of Scientific and Technical Information of China (English)

    曹立人; 苏昊; 曹珍副

    2004-01-01

    This study was aimed at investigating the sampling strategies for 2 types of figures: 3-D cubes and human faces. The research was focused on: (a) from where the sampling process started; (b) in what order the figures' features were sampled. The study consisted of 2 experiments: (a) sampling strategies for 3-D cubes; (b) sampling strategies for human faces. The results showed that: (a), for 3-D cubes, the first sampling was mostly located at the outline parts, rarely at the center part; while for human faces, the first sampling was mostly located at the hair and outline parts, rarely at the mouth or cheek parts, in most cases, the first sampling-position had no significant effects on cognitive performance and that (b), the sampling order, both for 3-D cubes and for human faces, was determined by the degree of difference among the sampled-features.

  19. A study on sampling strategies in the figure cognitive process

    Institute of Scientific and Technical Information of China (English)

    曹立人; 苏昊; 曹珍副

    2004-01-01

    This study was aimed at investigating the sampling strategies for 2 types of figures: 3-D cubes and human faces.The research was focused on: (a) from where the sampling process started; (b) in what order the figures' features were sampled. The study consisted of 2 experiments: (a) sampling strategies for 3-D cubes; (b) sampling strategies for human faces. The results showed that: (a), for 3-D cubes, the first sampling was mostly located at the outline parts, rarely at the center part; while for human faces, the first sampling was mostly located at the hair and outline parts, rarely at the mouth or cheek parts, in most cases, the first sampling-position had no significant effects on cognitive performance and that (b), the sampling order, both for 3-D cubes and for human faces, was determined by the degree of difference among the sampled-features.

  20. Revised sampling campaigns to provide sludge for treatment process testing

    Energy Technology Data Exchange (ETDEWEB)

    PETERSEN, C.A.

    1999-02-18

    The purpose of this document is to review the impact to the sludge sampling campaigns planned for FY 1999 given the recent decision to delete any further sludge sampling in the K West Basin. Requirements for Sludge sample material for Sludge treatment process testing are reviewed. Options are discussed for obtaining the volume sample material required and an optimized plan for obtaining this sludge is summarized.

  1. PHENIX on-line systems

    Energy Technology Data Exchange (ETDEWEB)

    Adler, S.S.; Allen, M.; Alley, G.; Amirikas, R.; Arai, Y.; Awes, T.C.; Barish, K.N.; Barta, F.; Batsouli, S.; Belikov, S.; Bennett, M.J.; Bobrek, M.; Boissevain, J.G.; Boose, S.; Britton, C.; Britton, L.; Bryan, W.L.; Cafferty, M.M.; Carey, T.A.; Chang, W.C.; Chi, C.Y.; Chiu, M.; Cianciolo, V.; Cole, B.A.; Constantin, P.; Cook, K.C.; Cunitz, H.; Desmond, E.J.; Ebisu, K.; Efremenko, Y.V.; El Chenawi, K.; Emery, M.S.; Engo, D.; Ericson, N.; Fields, D.E.; Frank, S.; Frantz, J.E.; Franz, A.; Frawley, A.D.; Fried, J.; Gannon, J.; Gee, T.F.; Gentry, R.; Giannotti, P.; Gustafsson, H.-A.; Haggerty, J.S.; Hahn, S.; Halliwell, J.; Hamagaki, H.; Hansen, A.G.; Hara, H.; Harder, J.; He, X.; Heistermann, F.; Hemmick, T.K.; Hibino, M.; Hill, J.C. E-mail: jhill@iastate.edu; Homma, K.; Jacak, B.V.; Jagadish, U.; Jia, J.; Kajihara, F.; Kametani, S.; Kamyshkov, Y.; Kandasamy, A.; Kang, J.H.; Kapustinsky, J.; Katou, K.; Kelley, M.A.; Kelly, S.; Kikuchi, J.; Kim, S.Y.; Kim, Y.G.; Kistenev, E.; Kotchetkov, D.; Kurita, K.; Lajoie, J.G.; Lenz, M.; Lenz, W.; Li, X.H.; Lin, S.; Liu, M.X.; Markacs, S.; Matathias, F.; Matsumoto, T.; Mead, J.; Mischke, R.E.; Mishra, G.C.; Moore, A.; Muniruzzamann, M.; Musrock, M.; Nagle, J.L.; Nandi, B.K.; Newby, J.; Nystrand, J.; O' Brien, E.; O' Connor, P.; Ohnishi, H.; Oskarsson, A.; Osterman, L.; Oyama, K.; Paffrath, L.; Pancake, C.E.; Pantuev, V.S.; Petridis, A.N.; Pisani, R.P.; Plagge, T.; Plasil, F.; Purschke, M.L.; Rankowitz, S.; Rao, R.; Rau, M.; Read, K.F.; Ryu, S.S.; Sakaguchi, T.; Sato, H.D.; Seto, R.; Shiina, T.; Silvermyr, D.; Simon-Gillo, J.; Simpson, M.; Sippach, W.; Skank, H.D.; Skutnik, S.; Sleege, G.A.; Smith, G.D.; Smith, M.; Stankus, P.W.; Steinberg, P.; Sugitate, T.; Sullivan, J.P.; Taketani, A.; Tamai, M.; Tanaka, Y.; Thomas, W.D.; Todd, R.; Toldo, F.; Turner, G.; Ushiroda, T.; Velkovska, J.; Hecke, H.W. van; Lith, M. van; Villatte, L.; Achen, W. von; Walker, J.W.; Wang, H.Q.; White, S.N.; Wintenberg, A.L.; Witzig, C.; Wood, L.[and others

    2003-03-01

    The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each detector subsystem for the purpose of generating events for physics analysis. Processing of event data begins when the Data Collection Modules (DCM) receive data via fiber-optic links from the FEMs. The DCMs format and zero suppress the data and generate data packets. These packets go to the Event Builders (EvB) that assemble the events in final form. The Level-1 trigger (LVL1) generates a decision for each beam crossing and eliminates uninteresting events. The FEMs carry out all detector processing of the data so that it is delivered to the DCMs using a standard format. The FEMs also provide buffering for LVL1 trigger processing and DCM data collection. This is carried out using an architecture that is pipelined and deadtimeless. All of this is controlled by the Master Timing System (MTS) that distributes the RHIC clocks. A Level-2 trigger (LVL2) gives additional discrimination. A description of the components and operation of the PHENIX On-Line system is given and the solution to a number of electronic infrastructure problems are discussed.

  2. Low power and high accuracy spike sorting microprocessor with on-line interpolation and re-alignment in 90 nm CMOS process.

    Science.gov (United States)

    Chen, Tung-Chien; Ma, Tsung-Chuan; Chen, Yun-Yu; Chen, Liang-Gee

    2012-01-01

    Accurate spike sorting is an important issue for neuroscientific and neuroprosthetic applications. The sorting of spikes depends on the features extracted from the neural waveforms, and a better sorting performance usually comes with a higher sampling rate (SR). However for the long duration experiments on free-moving subjects, the miniaturized and wireless neural recording ICs are the current trend, and the compromise on sorting accuracy is usually made by a lower SR for the lower power consumption. In this paper, we implement an on-chip spike sorting processor with integrated interpolation hardware in order to improve the performance in terms of power versus accuracy. According to the fabrication results in 90nm process, if the interpolation is appropriately performed during the spike sorting, the system operated at the SR of 12.5 k samples per second (sps) can outperform the one not having interpolation at 25 ksps on both accuracy and power.

  3. Enantioselective analysis of pheniramine in urine by charged CD-mediated CZE provided with a fiber-based DAD and an on-line sample pretreatment by capillary ITP.

    Science.gov (United States)

    Marák, Jozef; Mikus, Peter; Maráková, Katarína; Kaniansky, Dusan; Valásková, Iva; Havránek, Emil

    2007-08-01

    Application potentialities of CZE on-line coupled with capillary ITP and DAD to the identification and determination of trace concentration levels (microg/L) of pheniramine (PHM) enantiomers and their metabolites present in complex ionic matrices of biological origin (urine) are shown. An enhanced (enantio)selectivity of the CZE separation system obtained by the addition of carboxyethyl-beta-CD (CE-beta-CD) to the carrier electrolyte provided CZE conditions for a reliable identification of similar/identical DAD spectra of structurally related compounds (PHM enantiomers and their metabolites) in clinical urine samples differing in qualitative and quantitative composition of sample matrix constituents. A high sample loadability (a 30 microL sample injection volume), partial sample clean-up (removing macroconstituents from the sample), and preconcentration of the analytes in ITP stage resulted in the decrease of concentration LOD for PHM enantiomers in urine to 5.2 and 6.8 microg/L (2.2 x 10(-8) and 2.8 x 10(-8) mol/L), without using any sample pretreatment technique. The background correction and smoothing procedure applied to the raw DAD spectra provided analytically relevant DAD spectra of PHM enantiomers and their metabolites also when they were present in urine sample (30 microL injection volumes of ten-times diluted urine sample) at a 9 x 10(-) (8) mol/L concentration. DAD spectra of PHM enantiomers present in urine samples matched their reference spectra with reasonable certainties. DAD spectra of PHM metabolites were compared with the reference spectra of PHM enantiomers and a good match was found which indicates the similarities in the structures of enantiomers and their metabolites detected in the urine samples. This fact allows performing the quantitative analyses of PHM metabolites in the urine samples by applying the calibration parameters of PHM enantiomers also for PHM metabolites and the results show the possibilities of using the ITP

  4. Non-Contact Conductivity Measurement for Automated Sample Processing Systems

    Science.gov (United States)

    Beegle, Luther W.; Kirby, James P.

    2012-01-01

    A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

  5. On-line preconcentration using a resin functionalized with 3,4-dihydroxybenzoic acid for the determination of trace elements in biological samples by thermospray flame furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lemos, Valfredo A. [Universidade Estadual do Sudoeste da Bahia, Laboratorio de Quimica Analitica, Campus de Jequie, 45206-190 Jequie, Bahia (Brazil)], E-mail: vlemos@uesb.br; Bezerra, Marcos A. [Universidade Estadual do Sudoeste da Bahia, Laboratorio de Quimica Analitica, Campus de Jequie, 45206-190 Jequie, Bahia (Brazil); Universidade Federal da Bahia, Instituto de Quimica, Campus Universitario Ondina, 40170-290 Salvador, Bahia (Brazil); Amorim, Fabio A.C. [Universidade Federal da Bahia, Instituto de Quimica, Campus Universitario Ondina, 40170-290 Salvador, Bahia (Brazil); Universidade Federal da Bahia, Instituto de Ciencias Ambientais e Desenvolvimento Sustentavel, Campus de Barreiras, 40805-100 Barreiras, Bahia (Brazil)

    2008-09-15

    In the present paper, an on-line preconcentration procedure for determination of cadmium, copper and zinc by thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) is proposed. Amberlite XAD-4 functionalized with 3,4-dihydroxybenzoic acid (XAD4-DHB) packed in a minicolumn was used as sorbent material. The metals were retained on the XAD-DHB resin, from which it could be eluted directly to the thermospray flame furnace system. The detection limits were 28 (Cd), 100 (Cu) and 77 ng L{sup -1} (Zn) for 60 s preconcentration time, at a sample flow rate of 7.0 mL min{sup -1}. Enrichment factors were 102, 91 and 62, for cadmium, copper and zinc, respectively. The procedure has been applied successfully to metal determination in biological standard reference materials.

  6. Sample Handling and Processing on Mars for Future Astrobiology Missions

    Science.gov (United States)

    Beegle, Luther; Kirby, James P.; Fisher, Anita; Hodyss, Robert; Saltzman, Alison; Soto, Juancarlos; Lasnik, James; Roark, Shane

    2011-01-01

    In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes especially when detecting low concentration organic molecules that may identify extraterrestrial life. Sample processing for analytical instruments is time, resource and manpower consuming in terrestrial laboratories. Every step in this laborious process will have to be automated for in situ life detection. We have developed, and are currently demonstrating, an automated wet chemistry preparation system that can operate autonomously on Earth and is designed to operate under Martian ambient conditions. This will enable a complete wet chemistry laboratory as part of future missions. Our system, namely the Automated Sample Processing System (ASPS) receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species and delivers sample to multiple instruments for analysis (including for non-organic soluble species).

  7. Sample Handling and Processing on Mars for Future Astrobiology Missions

    Science.gov (United States)

    Beegle, Luther; Kirby, James P.; Fisher, Anita; Hodyss, Robert; Saltzman, Alison; Soto, Juancarlos; Lasnik, James; Roark, Shane

    2011-01-01

    In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes especially when detecting low concentration organic molecules that may identify extraterrestrial life. Sample processing for analytical instruments is time, resource and manpower consuming in terrestrial laboratories. Every step in this laborious process will have to be automated for in situ life detection. We have developed, and are currently demonstrating, an automated wet chemistry preparation system that can operate autonomously on Earth and is designed to operate under Martian ambient conditions. This will enable a complete wet chemistry laboratory as part of future missions. Our system, namely the Automated Sample Processing System (ASPS) receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species and delivers sample to multiple instruments for analysis (including for non-organic soluble species).

  8. Double Shell Tank (DST) Process Waste Sampling Subsystem Specification

    Energy Technology Data Exchange (ETDEWEB)

    RASMUSSEN, J.H.

    2000-05-03

    This specification establishes the performance requirements and provides references to the requisite codes and standards to be applied to the Double-Shell Tank (DST) Process Waste Sampling Subsystem which supports the first phase of Waste Feed Delivery.

  9. On-line coupling of flow field-flow fractionation and multiangle laser light scattering for the characterization of macromolecules in aqueous solution as illustrated by sulfonated polystyrene samples.

    Science.gov (United States)

    Thielking, H; Kulicke, W M

    1996-04-01

    Seven sulfonated polystyrene standards (18 000-3 000 000 g/mol), taken as model substances for macromolecular polyelectrolytes, were dissolved in aqueous 0.1 M sodium nitrate solution and characterized by multiangle laser light scattering coupled on-line to flow field-flow fractionation. The distributions of molar mass and root mean square radius and the diffusion coefficients were obtained for each sample using a constant field of force for separation. Relationships between molar mass and root mean square radius [〈R(G)(2)〉(z)(0.5) = (2.71 × 10(-)(2))M(w)(0.56)] or diffusion coefficient [D = (7.10 × 10(-)(8))M(w)(-)(0.68)] were calculated. To investigate the static analytical range of this novel hyphenated technique a mixture of all seven samples was fractionated applying a programmed field. The relationship obtained between root mean square radius and molar mass was used to calculate a Mark-Houwink equation [[η]calcd = (2.99 × 10(-)(2))M(w)(0.68)]. To verify this result, the intrinsic viscosities for all samples were measured at low shear rate and found to be in good agreement [[η]calcd = (2.77 × 10(-)(2))M(w)(0.67)].

  10. Preparation and characterization of magnetic nanoparticles for the on-line determination of gold, palladium, and platinum in mine samples based on flow injection micro-column preconcentration coupled with graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Ye, Juanjuan; Liu, Shuxia; Tian, Miaomiao; Li, Wanjun; Hu, Bin; Zhou, Weihong; Jia, Qiong

    2014-01-01

    A simple and highly selective procedure for on-line determination of trace levels of Au, Pd, and Pt in mine samples has been developed using flow injection-column adsorption preconcentration coupled with graphite furnace atomic absorption spectrophotometry (FI-column-GFAAS). The precious metals were adsorbed on the as-synthesized magnetic nanoparticles functionalized with 4'-aminobenzo-15-crown-5-ether packed into a micro-column and then eluted with 2% thiourea + 0.1 mol L(-1) HCl solution prior to the determination by GFAAS. The properties of the magnetic adsorbents were investigated by scanning electron microscope (SEM), X-ray diffraction (XRD), and vibrating sample magnetometer (VSM). Various experimental parameters affecting the preconcentration of Au, Pd, and Pt were investigated and optimized. Under the optimal experimental conditions, the detection limits of the developed technique were 0.16 ng mL(-1) for Au, 0.28 ng mL(-1) for Pd, and 1.01 ng mL(-1) for Pt, with enrichment factors of 24.3, 13.9, and 17.8, respectively. Precisions, evaluated as repeatability of results, were 1.1%, 3.9%, and 4.4% respectively for Au, Pd, and Pt. The developed method was validated by the analysis of Au, Pd, and Pt in certified reference materials and mine samples with satisfactory results. © 2013 Published by Elsevier B.V.

  11. On-Line Acquisitions by LOLITA

    Directory of Open Access Journals (Sweden)

    Frances G. Spigai

    1970-12-01

    Full Text Available The on-line acquisition program (LOLITA in use at the Oregon State University Library is described in terms of development costs, equipment requirements, and overall design philosophy. In particular, the record format and content of records in the on-order file, and the on-line processing of these records (input, search, correction, output using a cathode ray tube display terminal are detailed.

  12. Data Set for the manuscript entitled, "Sample Processing Approach for Detection of Ricin in Surface Samples."

    Data.gov (United States)

    U.S. Environmental Protection Agency — Figure. This dataset is associated with the following publication: Shah, S., S. Kane, A.M. Erler, and T. Alfaro. Sample Processing Approach for Detection of Ricin in...

  13. Mars Science Laboratory Sample Acquisition, Sample Processing and Handling: Subsystem Design and Test Challenges

    Science.gov (United States)

    Jandura, Louise

    2010-01-01

    The Sample Acquisition/Sample Processing and Handling subsystem for the Mars Science Laboratory is a highly-mechanized, Rover-based sampling system that acquires powdered rock and regolith samples from the Martian surface, sorts the samples into fine particles through sieving, and delivers small portions of the powder into two science instruments inside the Rover. SA/SPaH utilizes 17 actuated degrees-of-freedom to perform the functions needed to produce 5 sample pathways in support of the scientific investigation on Mars. Both hardware redundancy and functional redundancy are employed in configuring this sampling system so some functionality is retained even with the loss of a degree-of-freedom. Intentional dynamic environments are created to move sample while vibration isolators attenuate this environment at the sensitive instruments located near the dynamic sources. In addition to the typical flight hardware qualification test program, two additional types of testing are essential for this kind of sampling system: characterization of the intentionally-created dynamic environment and testing of the sample acquisition and processing hardware functions using Mars analog materials in a low pressure environment. The overall subsystem design and configuration are discussed along with some of the challenges, tradeoffs, and lessons learned in the areas of fault tolerance, intentional dynamic environments, and special testing

  14. Influence of volume of sample processed on detection of Chlamydia trachomatis in urogenital samples by PCR.

    OpenAIRE

    Goessens, Wil; Kluytmans, Jan; Toom, N.; van Rijsoort-Vos, T H; Stolz, Ernst; Verbrugh, Henri; Quint, Wim; Niesters, Bert

    1995-01-01

    textabstractIn the present study, it was demonstrated that the sensitivity of the PCR for the detection of Chlamydia trachomatis is influenced by the volume of the clinical sample which is processed in the PCR. An adequate sensitivity for PCR was established by processing at least 4%, i.e., 80 microliters, of the clinical sample volume per PCR. By using this preparation procedure, 1,110 clinical samples were evaluated by PCR and by cell culture, and results were compared. After discordant ana...

  15. On-line Ultrasound-Assisted Dispersive Micro-Solid-Phase Extraction Based on Amino Bimodal Mesoporous Silica Nanoparticles for the Preconcentration and Determination of Cadmium in Human Biological Samples.

    Science.gov (United States)

    Shirkhanloo, H; Falahnejad, M; Zavvar Mousavi, H

    2016-06-01

    On-line ultrasound-assisted dispersive micro-solid-phase extraction (USA-DμSPE) has been developed for preconcentration and separation of trace amounts of Cd(II) ions in 0.5 mL of human biological samples. In a syringe with a nylon membrane, new synthetic bulky amino bimodal mesoporous silica nanoparticles (NH2-UVM7) were dispersed as a nanoadsorbent in 5 mL of diluted serum sample (1:10), and after ultrasonic shaking, the liquid phase was separated from the solid phase. At the optimized pH, the chemical and physical adsorption of cadmium ions occurred, respectively, based on complexation with amine groups of UVM7 (Cd:NH2-UVM7) and silica nanoparticles. The analyte was then back-extracted from the sorbent with nitric acid solution (0.2 M), and its concentration was determined by electrothermal atomic absorption spectrometry (ETAAS). Under the optimized conditions, the linear range, limit of detection (LOD), and preconcentration factor (PF) were obtained as 0.01-0.56 μg L(-1), 0.002 μg L(-1), and 25, respectively. The adsorption capacity of NH2-UVM7 was found to be 108.6 mg g(-1) of cadmium. The validation of the methodology was performed by the human standard reference material (HSRM).

  16. Chemiluminescence determination of cefotaxime sodium with flow-injection analysis of cerium (IV)-rhodamine 6G system and its application to the binding study of cefotaxime sodium to protein with on-line microdialysis sampling

    Science.gov (United States)

    Chen, Dinglong; Wang, Huiying; Zhang, Zhujun; Ci, Lijie; Zhang, Xuehong

    2011-01-01

    A simple, sensitive and rapid flow-injection chemiluminescence (CL) method has been developed for the determination of cefotaxime sodium based on the chemiluminescence reaction of cefotaxime sodium with ceric sulfate and rhodamine 6G in nitric acid solution. The concentration of cefotaxime sodium was proportional with the CL intensity in the range of 4 × 10 -8 - 8 × 10 -6 mol L -1. The detection limit (signal-to-noise ratio = 3) was 1 × 10 -8 mol L -1. Coupled to the technique of on-line microdialysis sampling, this method was successfully applied to study cefotaxime sodium-protein interaction. The drug and protein were mixed in different molar ratios in Ringer's solution, pH 7.4, and incubated at 37 °C in a water bath. The microdialysis probe was utilized to sample the mixed solution at a perfusion rate of 5 μL min -1 and the recovery of cefotaxime sodium under experimental condition was 16.2%. The data obtained by the present Microdialysis-Flow Injection Analysis-CL method was analyzed with the Scatchard analysis and Klotz plot. The estimated association constant ( K) and the number of the binding sites ( n) on one of BSA molecule were 5.94 × 10 4 M -1 and 1.29 (Klotz equation), respectively.

  17. Sampling state and process variables on coral reefs.

    Science.gov (United States)

    Green, Roger H; McArdle, Brian A; van Woesik, Robert

    2011-07-01

    Contemporary coral reefs are forced to survive through and recover from disturbances at a variety of spatial and temporal scales. Understanding disturbances in the context of ecological processes may lead to accurate predictive models of population trajectories. Most coral-reef studies and monitoring programs examine state variables, which include the percentage coverage of major benthic organisms, but few studies examine the key ecological processes that drive the state variables. Here we outline a sampling strategy that captures both state and process variables, at a spatial scale of tens of kilometers. Specifically, we are interested in (1) examining spatial and temporal patterns in coral population size-frequency distributions, (2) determining major population processes, including rates of recruitment and mortality, and (3) examining relationships between processes and state variables. Our effective sampling units are randomly selected 75 × 25 m stations, spaced approximately 250-500 m apart, representing a 10(3) m spatial scale. Stations are nested within sites, spaced approximately 2 km apart, representing a 10(4) m spatial scale. Three randomly selected 16 m(2) quadrats placed in each station and marked for relocation are used to assess processes across time, while random belt-transects, re-randomized at each sampling event, are used to sample state variables. Both quadrats and belt-transects are effectively sub-samples from which we will derive estimates of means for each station at each sampling event. This nested sampling strategy allows us to determine critical stages in populations, examine population performance, and compare processes through disturbance events and across regions.

  18. Influence of volume of sample processed on detection of Chlamydia trachomatis in urogenital samples by PCR

    NARCIS (Netherlands)

    Goessens, W H; Kluytmans, J A; den Toom, N; van Rijsoort-Vos, T H; Niesters, B G; Stolz, E; Verbrugh, H A; Quint, W G

    In the present study, it was demonstrated that the sensitivity of the PCR for the detection of Chlamydia trachomatis is influenced by the volume of the clinical sample which is processed in the PCR. An adequate sensitivity for PCR was established by processing at least 4%, i.e., 80 microliters, of

  19. Influence of volume of sample processed on detection of Chlamydia trachomatis in urogenital samples by PCR

    NARCIS (Netherlands)

    Goessens, W H; Kluytmans, J A; den Toom, N; van Rijsoort-Vos, T H; Niesters, B G; Stolz, E; Verbrugh, H A; Quint, W G

    1995-01-01

    In the present study, it was demonstrated that the sensitivity of the PCR for the detection of Chlamydia trachomatis is influenced by the volume of the clinical sample which is processed in the PCR. An adequate sensitivity for PCR was established by processing at least 4%, i.e., 80 microliters, of t

  20. Influence of volume of sample processed on detection of Chlamydia trachomatis in urogenital samples by PCR

    NARCIS (Netherlands)

    W.H.F. Goessens (Wil); J.A.J.W. Kluytmans (Jan); N. den Toom; T.H. van Rijsoort-Vos; E. Stolz (Ernst); H.A. Verbrugh (Henri); W.G.V. Quint (Wim); H.G.M. Niesters (Bert)

    1995-01-01

    textabstractIn the present study, it was demonstrated that the sensitivity of the PCR for the detection of Chlamydia trachomatis is influenced by the volume of the clinical sample which is processed in the PCR. An adequate sensitivity for PCR was established by processing at least

  1. On-line focusing of 5-hydroxy-tryptamine type 3 receptor antagonists via the combination of field-enhanced sample injection and dynamic pH junction in capillary electrophoresis with amperometric detection.

    Science.gov (United States)

    Li, Libo; Xu, Lei; Huang, Jianshe; You, Tianyan

    2014-02-28

    In the present work, an on-line dual focusing technique based on field-enhance sample injection (FASI) and dynamic pH junction (DypH) was developed for the analysis of two 5-hydroxy-tryptamine type 3 receptor (5-HT3) antagonists ondansetron (Ond) and tropisetron (Tro) by capillary electrophoresis with amperometric detection (CE-AD) system. By preparing the sample in a lower conductivity (FASI condition) and lower pH value (DypH condition) matrix relative to the background electrolyte (BGE) solution, a simple and effective dual focusing approach, FASI-DypH was achieved. In this stacking mode, a large amount of analytes could be electrokinetically injected into the capillary and stacked at the boundary of the sample and the BGE zone as a result of deprotonation and decrease in the electric field. Effects of separation, detection and FASI-DypH focusing conditions were investigated in detail. Under the optimum conditions, good separation for Ond and Tro was achieved within 8min. In comparison with the conventional CE-AD analysis method, the present dual focusing technique enabled the enhancement factors in terms of peak heights to reach 357-fold and 345-fold for Ond and Tro, respectively. The limits of detection (LODs) (S/N=3) for Ond and Tro were 2nM and 5nM, respectively. The intraday and interday repeatabilities (RSDs) were less than 4.5% and 2.9% for peak height and migration time, respectively. The proposed method was successfully applied for the analysis of Ond and Tro in human urine sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. 基于支持向量机MPLS的间歇过程故障诊断方法%On-line Fault Detection Using SVM-based Dynamic MPLS for Batch Processes

    Institute of Scientific and Technical Information of China (English)

    李运锋; 汪志锋; 袁景淇

    2006-01-01

    In this article, a nonlinear dynamic multiway partial least squares (MPLS) based on support vector machines (SVM) is developed for on-line fault detection in batch processes. The approach, referred to as SVM-based DMPLS, integrates the SVM with the MPLS model. Process data from normal historical batches are used to develop the MPLS model, and a series of single-input-single-output SVM networks are adopted to approximate nonlinear inner relationship between input and output variables. In addition, the application of a time-lagged window technique not only makes the complementarities of unmeasured data of the monitored batch unnecessary, but also significantly reduces the computation and storage requirements in comparison with the traditional MPLS. The proposed approach is validated by a simulation study of on-line fault detection for a fed-batch penicillin production.

  3. Determination of Cr (Ⅵ) in Water Sample After Preconcentration by On-line Ion Exchange FLAAS%在线离子交换预富集-FLAAS测定环境水样中的铬(Ⅵ)

    Institute of Scientific and Technical Information of China (English)

    李丹; 俞晓峰; 寿淼钧; 叶华俊; 韩双来

    2013-01-01

    采用在线离子交换预富集-火焰原子吸收光谱法(FLAAS)测定环境水样中痕量铬(Ⅵ).通过试验考察样品溶液pH、洗脱剂浓度、离子交换树脂用量及共存离子对离子交换树脂富集效果的影响.结果表明,当交换树脂用量为0.50 g,样品溶液pH值为6.0时,用0.60 mol/L盐酸-10%抗坏血酸进行洗脱具有良好效果.铬(Ⅵ)的质量浓度在0~20.0μg/L之间与吸光度呈良好的线性关系,线性相关系数大于0.9998.该方法用于在线分离和富集环境水样中的铬(Ⅵ),灵敏度提高了100倍,加标回收率为96%~104%.%Trace amount of Cr( VI) was determined by using on-line ion-exchange column preconcentration flame atomic absorption spectroscopy system (IE-FLAAS). The effects of experimental variables such as the pH of sample, the concentration of eluent, the content of ion-exchange resin and coexisting ions on the recovery of Cr( VI) were inspected. The optimum operation conditions were as follows:the content of ion-exchange resin was 0.50 g, the pH of solution was 6.0, the eluent was 0.60 mol/L HCl-10% ascorbic acid. The mass concentration of Cr( VI) was linear with absorbance in the range of 0-20.0 μl g/L, the correlation coefficient was more than 0.999. The proposed method was used for on-line separation and preconcentration of Cr( VI) in water sample, the sensitivity of IE-FLAAS was 100 times higher than that of FLAAS and recovery was in the range of 96%-104%.

  4. Membrane Extraction and Flow Injection for On-Line Sample Preparation%膜萃取和流动注射在线样品前处理技术

    Institute of Scientific and Technical Information of China (English)

    刘景富; 江桂斌

    2003-01-01

    The objective of this dissertation is to develop on-line sample preparation procedures based on membrane extraction and flow injection (FI) techniques. A novel sample pretreatment technique, which we termed continuous flow liquid membrane extraction(CFLME), was developed for trace-enrichment of polar organic pollutants. The principle and parameters of CFLME were investigated by using sulfonylurea herbicides and bisphenol A as model compounds. At the optimum conditions and with an enrichment time of 120 min and 40 min, metsulfuron methyl and bisphenol A were enriched with an enrichment factor of 1000 and 200, respectively, and the enrichment efficiencies of bisphenol A and the five studied sulfonylurea herbicides were 3.5 ~ 200 fold of that of supported liquid membrane extraction (SLM). Then,an on-line coupled CFLME-HPLC system, with detection limits of 0.05 ~ 0.1 μg/L after 10min of enrichment, was developed for the determination of sulfonylurea herbicides. Futhermore, an on-line coupled CFLME-C18 precolumn-HPLC system was developed for the trace analysis of sulfonylurea herbicides in surface waters at ng/L level. The detection limit of this proposed CFLME-C18 precolumn-HPLC system is 200 fold lower than that of the original C18SPE preconcentration-HPLC detection method. Experiments show that the proposed CFLME technique has the advantages of high selectivity, high enrichment efficiency, low-cost, longterm stability and convenience for coupling on-line with other analytical instruments.On-line sample pretreatment procedures based on FI technique were also studied and approaches for the application of FI technique in routine analysis were proposed. A FI-micropore membrane liquid-liquid system was developed for the routine analysis of anionic surfactants in detergents, and a FI high temperature reaction system was developed for the determination of total inorganic phosphates in detergents and the total reducing sugars in tobacco. To simplify the manifold

  5. ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T.; Hera, K.; Coleman, C.; Jones, M.; Wiedenman, B.

    2011-12-05

    Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1). This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from

  6. Importance sampling for jump processes and applications to finance

    OpenAIRE

    Badouraly Kassim, Laetitia; Lelong, Jérôme; Loumrhari, Imane

    2013-01-01

    International audience; Adaptive importance sampling techniques are widely known for the Gaussian setting of Brownian driven diffusions. In this work, we want to extend them to jump processes. Our approach relies on a change of the jump intensity combined with the standard exponential tilting for the Brownian motion. The free parameters of our framework are optimized using sample average approximation techniques. We illustrate the efficiency of our method on the valuation of financial derivat...

  7. Determination of Cd in biological samples by flame AAS following on-line preconcentration by complexation with O,O-diethyldithiophosphate and solid phase extraction with Amberlite XAD-4.

    Science.gov (United States)

    Santos, Eder José Dos; Herrmann, Amanda Beatriz; Ribeiro, Anderson Schwingel; Curtius, Adilson José

    2005-01-30

    A method for the on-line preconcentration of Cd based on its complex formation with the ammonium salt of O,O-diethylditiophosphate (DDTP) and using the Amberlite XAD-4 resin as a solid support in a column is proposed. Cadmium was detected by flame atomic absorption spectrometry. Different conditions, such as complexing agent concentration, preconcentration time, solutions flow rates and nature and concentration of the eluent were optimized. Different detection limits (LODs) could be established by using different preconcentration times, between 30s and 5min, with corresponding LODs from 5 to 1mugL(-1), respectively. The method was validated by analyzing five biological certified samples. The relative standard deviation was usually around 3%, indicating a very good precision. The found concentrations values are in agreement with the certified ones, according to the t-test, for a confidence level of 95%. Enriched seawaters were also analyzed, and the recoveries were between 93 and 108%. The FI method is very simple and probably can be coupled to other measuring analytical techniques.

  8. Proteome sampling by the HLA class I antigen processing pathway.

    Directory of Open Access Journals (Sweden)

    Ilka Hoof

    Full Text Available The peptide repertoire that is presented by the set of HLA class I molecules of an individual is formed by the different players of the antigen processing pathway and the stringent binding environment of the HLA class I molecules. Peptide elution studies have shown that only a subset of the human proteome is sampled by the antigen processing machinery and represented on the cell surface. In our study, we quantified the role of each factor relevant in shaping the HLA class I peptide repertoire by combining peptide elution data, in silico predictions of antigen processing and presentation, and data on gene expression and protein abundance. Our results indicate that gene expression level, protein abundance, and rate of potential binding peptides per protein have a clear impact on sampling probability. Furthermore, once a protein is available for the antigen processing machinery in sufficient amounts, C-terminal processing efficiency and binding affinity to the HLA class I molecule determine the identity of the presented peptides. Having studied the impact of each of these factors separately, we subsequently combined all factors in a logistic regression model in order to quantify their relative impact. This model demonstrated the superiority of protein abundance over gene expression level in predicting sampling probability. Being able to discriminate between sampled and non-sampled proteins to a significant degree, our approach can potentially be used to predict the sampling probability of self proteins and of pathogen-derived proteins, which is of importance for the identification of autoimmune antigens and vaccination targets.

  9. MIS On-Line.

    Science.gov (United States)

    Thomson, Nancy S.; Echeverria, Donna Rose; Mills, Bob

    This paper describes the resources, processes and outcomes involved in the development of an introductory Management Information Systems (MIS) course designed to utilize as many of the technologies as possible to redefine the teaching/learning paradigm. The MIS-Online project at Northwest Missouri State University encompasses the available campus…

  10. Development of an automated data processing method for sample to sample comparison of seized methamphetamines.

    Science.gov (United States)

    Choe, Sanggil; Lee, Jaesin; Choi, Hyeyoung; Park, Yujin; Lee, Heesang; Pyo, Jaesung; Jo, Jiyeong; Park, Yonghoon; Choi, Hwakyung; Kim, Suncheun

    2012-11-30

    The information about the sources of supply, trafficking routes, distribution patterns and conspiracy links can be obtained from methamphetamine profiling. The precursor and synthetic method for the clandestine manufacture can be estimated from the analysis of minor impurities contained in methamphetamine. Also, the similarity between samples can be evaluated using the peaks that appear in chromatograms. In South Korea, methamphetamine was the most popular drug but the total seized amount of methamphetamine whole through the country was very small. Therefore, it would be more important to find the links between samples than the other uses of methamphetamine profiling. Many Asian countries including Japan and South Korea have been using the method developed by National Research Institute of Police Science of Japan. The method used gas chromatography-flame ionization detector (GC-FID), DB-5 column and four internal standards. It was developed to increase the amount of impurities and minimize the amount of methamphetamine. After GC-FID analysis, the raw data have to be processed. The data processing steps are very complex and require a lot of time and effort. In this study, Microsoft Visual Basic Application (VBA) modules were developed to handle these data processing steps. This module collected the results from the data into an Excel file and then corrected the retention time shift and response deviation generated from the sample preparation and instruments analysis. The developed modules were tested for their performance using 10 samples from 5 different cases. The processed results were analyzed with Pearson correlation coefficient for similarity assessment and the correlation coefficient of the two samples from the same case was more than 0.99. When the modules were applied to 131 seized methamphetamine samples, four samples from two different cases were found to have the common origin and the chromatograms of the four samples were appeared visually identical

  11. On-Line Tests

    Directory of Open Access Journals (Sweden)

    Florentina Anica Pintea

    2007-01-01

    Full Text Available This paper presents an interactive implementation which makes the link between a human operator and a system of an administration of relational databases MySQL. This application conceived as a multimedia presentations is illustrative for the way in which the transfer and the remaking of the information between the human operator, the module of data processing and the database which stores the information can be solved (with help of the PHP language and the web use.

  12. Challenging genosensors in food samples: The case of gluten determination in highly processed samples.

    Science.gov (United States)

    Martín-Fernández, Begoña; de-los-Santos-Álvarez, Noemí; Martín-Clemente, Juan Pedro; Lobo-Castañón, María Jesús; López-Ruiz, Beatriz

    2016-01-01

    Electrochemical genosensors have undergone an enormous development in the last decades, but only very few have achieved a quantification of target content in highly processed food samples. The detection of allergens, and particularly gluten, is challenging because legislation establishes a threshold of 20 ppm for labeling as gluten-free but most genosensors expresses the results in DNA concentration or DNA copies. This paper describes the first attempt to correlate the genosensor response and the wheat content in real samples, even in the case of highly processed food samples. A sandwich-based format, comprising a capture probe immobilized onto the screen-printed gold electrode, and a signaling probe functionalized with fluorescein isothiocyanate (FITC), both hybridizing with the target was used. The hybridization event was electrochemically monitored by adding an anti-FITC peroxidase (antiFITC-HRP) and its substrate, tetramethylbenzidine. Binary model mixtures, as a reference material, and real samples have been analyzed. DNA from food was extracted and a fragment encoding the immunodominant peptide of α2-gliadin amplified by a tailored PCR. The sensor was able to selectively detect toxic cereals for celiac patients, such as different varieties of wheat, barley, rye and oats, from non-toxic plants. As low as 0.001% (10 mg/kg) of wheat flour in an inert matrix was reliably detected, which directly compete with the current method of choice for DNA detection, the real-time PCR. A good correlation with the official immunoassay was found in highly processed food samples.

  13. Low sampling frequency processing for ultra-wideband signals

    Science.gov (United States)

    Wan, Yonglun; Si, Qiang; Lu, Youxin; Wang, Hong; Wang, Xuegang

    2005-11-01

    Ultra-wideband (UWB) signals are widely used in radar, navigation and satellite communications. It is rather difficult to process UWB signals. In this paper we adopt dechirp pulse compression method to process the received UWB linear frequency modulated (LFM) signals. UWB signals are converted into signals with frequency components that are proportional to the relative range between the target and the reference target. It means to select low-speed analog-to-digital converters (ADC) for sampling UWB signals. The simulation results show that LFM signal with 600MHz center frequency, 200MHz bandwidth and 30usec pulse width can be processed under 70MHz sampling frequency by means of the method.

  14. ACTINIDE REMOVAL PROCESS SAMPLE ANALYSIS, CHEMICAL MODELING, AND FILTRATION EVALUATION

    Energy Technology Data Exchange (ETDEWEB)

    Martino, C.; Herman, D.; Pike, J.; Peters, T.

    2014-06-05

    Filtration within the Actinide Removal Process (ARP) currently limits the throughput in interim salt processing at the Savannah River Site. In this process, batches of salt solution with Monosodium Titanate (MST) sorbent are concentrated by crossflow filtration. The filtrate is subsequently processed to remove cesium in the Modular Caustic Side Solvent Extraction Unit (MCU) followed by disposal in saltstone grout. The concentrated MST slurry is washed and sent to the Defense Waste Processing Facility (DWPF) for vitrification. During recent ARP processing, there has been a degradation of filter performance manifested as the inability to maintain high filtrate flux throughout a multi-batch cycle. The objectives of this effort were to characterize the feed streams, to determine if solids (in addition to MST) are precipitating and causing the degraded performance of the filters, and to assess the particle size and rheological data to address potential filtration impacts. Equilibrium modelling with OLI Analyzer{sup TM} and OLI ESP{sup TM} was performed to determine chemical components at risk of precipitation and to simulate the ARP process. The performance of ARP filtration was evaluated to review potential causes of the observed filter behavior. Task activities for this study included extensive physical and chemical analysis of samples from the Late Wash Pump Tank (LWPT) and the Late Wash Hold Tank (LWHT) within ARP as well as samples of the tank farm feed from Tank 49H. The samples from the LWPT and LWHT were obtained from several stages of processing of Salt Batch 6D, Cycle 6, Batch 16.

  15. Formación on line On line learning

    Directory of Open Access Journals (Sweden)

    O. Grau-Perejoan

    2008-09-01

    Full Text Available La formación on line es una modalidad de enseñanza a distancia basada en las nuevas tecnologías. En este artículo se pretende hacer una introducción a base de describir a grandes rasgos sus características principales: asincronía, no presencialidad, comunicación escrita, función del profesor on line, así como los retos, los riesgos, las ventajas y los inconvenientes que plantea. Se exponen las diferencias entre la formación on line y la formación presencial, de manera que los docentes puedan adaptar de la mejor manera posible sus propuestas formativas a la modalidad on line. Se introduce el importantísimo papel de la planificación y de la fase de diseño y, finalmente, se repasan conceptos útiles para comprender mejor el mundo de la formación on line como son los conceptos entorno virtual de aprendizaje (EVA o Blended Learning (B-Learning.On line learning is a type of distance education based on new technologies. This article's aim is to introduce its main characteristics -asynchrony, non-presentiality, written communication, e-teacher role- as well as its challenges, risks, advantages and limitations. Differences between on line learning and face-to-face learning are presented in order to enable educational professionals to adapt their courses to the on line methodology. Planning and designing are introduced as key phases and, finally, useful concepts such as Virtual Learning Environment (VLE or Blended Learning (B-Learning are reviewed in order to achieve a better understanding of the on line learning field.

  16. Designing a Repetitive Group Sampling Plan for Weibull Distributed Processes

    Directory of Open Access Journals (Sweden)

    Aijun Yan

    2016-01-01

    Full Text Available Acceptance sampling plans are useful tools to determine whether the submitted lots should be accepted or rejected. An efficient and economic sampling plan is very desirable for the high quality levels required by the production processes. The process capability index CL is an important quality parameter to measure the product quality. Utilizing the relationship between the CL index and the nonconforming rate, a repetitive group sampling (RGS plan based on CL index is developed in this paper when the quality characteristic follows the Weibull distribution. The optimal plan parameters of the proposed RGS plan are determined by satisfying the commonly used producer’s risk and consumer’s risk at the same time by minimizing the average sample number (ASN and then tabulated for different combinations of acceptance quality level (AQL and limiting quality level (LQL. The results show that the proposed plan has better performance than the single sampling plan in terms of ASN. Finally, the proposed RGS plan is illustrated with an industrial example.

  17. Tracking Evolutionary Processes with Large Samples of Galaxy Pairs

    CERN Document Server

    Barton, Elizabeth J; Bullock, James S; Wright, Shelley A

    2009-01-01

    Modern redshift surveys enable the identification of large samples of galaxies in pairs, taken from many different environments. Meanwhile, cosmological simulations allow a detailed understanding of the statistical properties of the selected pair samples. Using these tools in tandem leads to a quantitative understanding of the effects of galaxy-galaxy interactions and, separately, the effects quenching processes in the environments of even very small groups. In the era of the next generation of large telescopes, detailed studies of interactions will be enabled to much higher redshifts.

  18. Remote operation of Defense Waste Processing Facility sampling stations

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, D E; Gunnels, D L

    1985-01-01

    A full-scale liquid sampling station mockup for the Defense Waste Processing Facility (DWPF) at the Savannah River Laboratory (SRL) demonstrated successful remote operation and replacement of all valves and instruments using master/slave manipulators in a clean atmosphere before similar stations are placed in a radioactive cell. Testing of the sample stations demonstrated the limitations of the manipulators which resulted in minor design changes that were easily accomplished in a clean cell. These same changes would have been difficult and very costly to make in a radioactive environment. 6 figs.

  19. Preliminary results on the determination of ultratrace amounts of cadmium in tea samples using a flow injection on-line solid phase extraction separation and preconcentration technique to couple with a sequential injection hydride generation atomic fluorescence spectrometry.

    Science.gov (United States)

    Duan, Taicheng; Song, Xuejie; Jin, Dan; Li, Hongfei; Xu, Jingwei; Chen, Hangting

    2005-10-31

    In this work, a method was developed for determination of ultra-trace levels of Cd in tea samples by atomic fluorescence spectrometry (AFS). A flow injection solid phase extraction (FI-SPE) separation and preconcentration technique, to on-line couple with a sequential injection hydride generation (SI-HG) technique is employed in this study. Cd was preconcentrated on the SPE column, which was made from a neutral extractant named Cyanex 923, while other matrix ions or interfering ions were completely or mostly separated off. Conditions for the SPE separation and preconcentration, as well as conditions for the HG technique, were studied. Due to the separation of interfering elements, Cd hydride generation efficiency could be greatly enhanced with the sole presence of Co(2+) with a concentration of 200mugL(-1), which is much lower than those in other works previously reported. Interferences on both the Cd separation and preconcentration, and Cd hydride generation (HG) were investigated; it showed that both the separation and preconcentration system, and the HG system had a strong anti-interference ability. The SPE column could be repeatedly used at least 400 times, a R.S.D. of 0.97% was obtained for 6 measurements of Cd with 0.2mugL(-1) and a correlation coefficiency of 1.0000 was obtained for the measurement of a series of solutions with Cd concentrations from 0.1 to 2mugL(-1). The method has a low detection limit of 10.8ngL(-1) for a 25mL solution and was successfully validated by using two tea standard reference materials (GBW08513 and GBW07605).

  20. Eigenvalue distribution of large sample covariance matrices of linear processes

    CERN Document Server

    Pfaffel, Oliver

    2012-01-01

    We derive the distribution of the eigenvalues of a large sample covariance matrix when the data is dependent in time. More precisely, the dependence for each variable $i=1,...,p$ is modelled as a linear process $(X_{i,t})_{t=1,...,n}=(\\sum_{j=0}^\\infty c_j Z_{i,t-j})_{t=1,...,n}$, where $\\{Z_{i,t}\\}$ are assumed to be independent random variables with finite fourth moments. If the sample size $n$ and the number of variables $p=p_n$ both converge to infinity such that $y=\\lim_{n\\to\\infty}{n/p_n}>0$, then the empirical spectral distribution of $p^{-1}\\X\\X^T$ converges to a non\\hyp{}random distribution which only depends on $y$ and the spectral density of $(X_{1,t})_{t\\in\\Z}$. In particular, our results apply to (fractionally integrated) ARMA processes, which we illustrate by some examples.

  1. Properties of large-scale melt-processed YBCO samples

    Science.gov (United States)

    Gauss, S.; Elschner, S.; Bestgen, H.

    Magnetic bearings and superconducting permanent magnets are some of the first possible applications of bulk high Tc superconductors. Large samples were prepared by a new melt process starting from reacted YBCO 123 and 211 powders. The addition of PtO 2 to the mixture led to reduced 211 inclusion size and better homogeneity. Simultaneously the density of microcracks dividing the a- b basal plane was reduced. For testing the overall magnetic properties of these samples magnetization and levitation force measurements were performed. In comparison to samples without PtO 2 addition a strong increase in the magnetization M and the repulsion force from a magnet were observed. The maximum in the field dependence of M increased to more than 1000 G. According to the time dependence of the trapped field after a field cooling experiment an acceptable flux creep at 77 K for a long-term application was achieved.

  2. Using Eye-Tracking to Study the On-Line Processing of Case-Marking Information among Intermediate L2 Learners of German

    Science.gov (United States)

    Jackson, Carrie N.; Dussias, Paola E.; Hristova, Adelina

    2012-01-01

    This study uses eye-tracking to examine the processing of case-marking information in ambiguous subject- and object-first wh-questions in German. The position of the lexical verb was also manipulated via verb tense to investigate whether verb location influences how intermediate L2 learners process L2 sentences. Results show that intermediate L2…

  3. Bimeasures and Sampling Theorems for Weakly Harmonizable Processes.

    Science.gov (United States)

    1982-09-27

    representation theorem and then such a measure has a unique extension of being a Radon measure by the standard theory of Bourbaki (1], one refers to each such...nontrivial, and this approach has other drawbacks. We therefore do not consider this set in the general format of the sampling theory of random processes...for a more general Cramer class. To carry out this analysis, it is neces- sary to use the properties of bimeasures. Some aspects of the bimeasure theory

  4. ON-LINE DOCUMENTS CONTENT MANAGEMENT

    Directory of Open Access Journals (Sweden)

    VASILESCU RAMONA VIOLETA

    2010-05-01

    Full Text Available This paper outlines the steps and technologies used in developing an on-line application server with many desktop clients, and with high power processing for a wide range of input documents to obtain searchable documents on the highest portability standards, PDF and PDF /A.

  5. On-line Monitoring for Phosphorus Removal Process and Bacterial Community in Sequencing Batch Reactor%SBR工艺除磷过程与种群结构在线监测

    Institute of Scientific and Technical Information of China (English)

    崔有为; 王淑莹; 李晶

    2009-01-01

    For efficient energy consumption and control of effluent quality, the cycle duration for a sequencing batch reactor (SBR) needs to be adjusted by real-time control according to the characteristics and loading of waste-water. In this study, an on-line information system for phosphorus removal processes was established. Based on the analysis for four systems with different ecological community structures and two operation modes, anaerobic-aerobic process and anaerobic-anaerobic process, the characteristic patterns of oxidation-reduction potential (ORP) and pH were related to phosphorous dynamics in the anaerobic, anoxic and aerobic phases, for determination of the end of phosphorous removal. In the operation mode of anaerobic-aerobic process, the pH profile in the anaerobic phase was used to estimate the relative amount of phosphorous accumulating organisms (PAOs) and glycogen accumulat- ing organisms (GAOs), which is beneficial to early detection of ecology community shifts. The on-line sensor val-ue of pH and ORP may be used as the parameters to adjust the duration for phosphorous removal and community shifts to cope with influent variations and maintain appropriate operation conditions.

  6. Sediment sampling and processing methods in Hungary, and possible improvements

    Science.gov (United States)

    Tamas, Eniko Anna; Koch, Daniel; Varga, Gyorgy

    2016-04-01

    The importance of the monitoring of sediment processes is unquestionable: sediment balance of regulated rivers suffered substantial alterations in the past century, affecting navigation, energy production, fish habitats and floodplain ecosystems alike; infiltration times to our drinking water wells have shortened, exposing them to an eventual pollution event and making them vulnerable; and sediment-attached contaminants accumulate in floodplains and reservoirs, threatening our healthy environment. The changes in flood characteristics and rating curves of our rivers are regularly being researched and described, involving state-of-the-art measurement methods, modeling tools and traditional statistics. Sediment processes however, are much less known. Unlike the investigation of flow processes, sediment-related research is scarce, which is partly due to the outdated methodology and poor database background in the specific field. Sediment-related data, information and analyses form an important and integral part of Civil engineering in relation to rivers all over the world. In relation to the second largest river of Europe, the Danube, it is widely known in expert community and for long discussed at different expert forums that the sediment balance of the river Danube has changed drastically over the past century. Sediment monitoring on the river Danube started as early as the end of the 19th century, with scattered measurements carried out. Regular sediment sampling was developed in the first half of the 20th century all along the river, with different station density and monitoring frequencies in different countries. After the first few decades of regular sampling, the concept of (mainly industrial) development changed along the river and data needs changed as well, furthermore the complicated and inexact methods of sampling bed load on the alluvial reach of the river were not developed further. Frequency of suspended sediment sampling is very low along the river

  7. On line routing per mobile phone

    DEFF Research Database (Denmark)

    Bieding, Thomas; Görtz, Simon; Klose, Andreas

    2009-01-01

    . Additionally it is of utmost importance that the employed communication system is suitable integrated with the firm’s enterprise application system and business processes. On basis of a case study, we describe in this paper a system that is cheap and easy to implement due to the use of simple mobile phones......On-line routing is concerned with building vehicle routes in an ongoing fashion in such a way that customer requests arriving dynamically in time are efficiently and effectively served. An indispensable prerequisite for applying on-line routing methods is mobile communication technology...

  8. Preparation of an epitope-imprinted polymer with antibody-like selectivity for beta2-microglobulin and application in serum sample analysis with a facile method of on-line solid-phase extraction coupling with high performance liquid chromatography.

    Science.gov (United States)

    Yang, Fangfang; Deng, Dandan; Dong, Xiangchao; Lin, Shen

    2017-03-09

    Molecularly imprinted polymers (MIPs) for protein recognition have great application potential in the biological analysis. However, preparation of protein imprinted polymer is still facing challenge. Beta2-microglobulin (β2m) is a protein biomarker that can be used in diagnosis of different diseases. In this research, a novel MIP with ability of β2m recognition has been developed by epitope and surface-confined imprinting approaches. A peptide with sequence of MIQRTPKIQ was selected as template. A strategy of combination of hierarchical imprinting and template immobilization was employed in the β2m-MIP synthesis. Imprinted binding sites with open-entrance have been created that have good accessibility for β2m and facilitated fast reversible binding kinetics. The experimental results demonstrated that the MIP has good selectivity. It can differentiate the template from peptide with different sequence and distinguish the β2m from other proteins with similar size and pI values. After binding property study of the β2m-MIP, a method of β2m determination in serum was established in which β2m was on-line extracted by MIP and analyzed by HPLC process. The recoveries for spiked serum was ≥83% with RSD <1.1%, indicating that the method has good accuracy and precisions. The LOD and LOQ were 0.058 and 0.195mgL(-1) respectively, which meet the requirements of the β2m analysis. The successful application of the β2m-MIP demonstrated that β2m has reversible binding on the MIP with a kinetics that can meet the requirements of the HPLC analysis. It also indicated that the β2m-MIP has good mechanical strength and reusability that can be applied reliably in the practical analysis. As a synthetic antibody, β2m-MIP is advantageous compared to the biological molecules.

  9. On-line in-situ diagnostics of processes within PEM fuel cells by the application of a Raman fiber technique

    Energy Technology Data Exchange (ETDEWEB)

    Bettermann, Hans; Fischer, Peter [Duesseldorf Univ. (Germany). Inst. fuer Physikalische Chemie

    2010-07-01

    This contribution presents two experimental setups that make use of such components. The first setup that first demonstrates the feasibility of applying Raman spectroscopy for studying processes inside fuel cells combines a self-constructed Raman microscope with a suitable model fuel cell. The first concept of looking inside the fuel cell was then extended to an approach which allows the simultaneous detection of Raman spectra from seven points of a flow field canal. The issue of this experimental approach is to provide long-time measurements for pursuing local and global processes. (orig.)

  10. The Role of Explicit Information in Instructed SLA: An On-Line Study with Processing Instruction and German Accusative Case Inflections

    Science.gov (United States)

    Culman, Hillah; Henry, Nicholas; VanPatten, Bill

    2009-01-01

    The present study reports the findings of an experiment on the effects of explicit information on the learning of German case markings. Fifty-nine learners of first- and second-year German received computer-based processing instruction on German accusative case marking and word order. These learners were divided into two groups: one received…

  11. Tar formation in a steam-O2 blown CFB gasifier and a steam blown PBFB gasifier (BabyHPR): Comparison between different on-line measurement techniques and the off-line SPA sampling and analysis method

    NARCIS (Netherlands)

    Meng, X.; Mitsakis, P.; Mayerhofen, M.; De Jong, W.; Gaderer, M.; Verkooijen, A.H.M.; Spliethoff, H.

    2012-01-01

    Two on-line tar measurement campaigns were carried out using an atmospheric pressure 100 “”kWth steam-O2 blown circulating fluidized bed (CFB) gasifier at the Delft University of Technology (TUD) and a 30–40kWth steam blown pressurized bubbling fluidized bed (PBFB) gasifier BabyHPR (Heatpipe Reforme

  12. On-line Fault Diagnosis in Industrial Processes Using Variable Moving Window and Hidden Markov Model%基于变长度移动窗口和HMM的工业过程故障在线诊断

    Institute of Scientific and Technical Information of China (English)

    周韶园; 谢磊; 王树青

    2005-01-01

    An integrated framework is presented to represent and classify process data for on-line identifying abnormal operating conditions. It is based on pattern recognition principles and consists of a feature extraction step, by which wavelet transform and principal component analysis are used to capture the inherent characteristics from process measurements, followed by a similarity assessment step using hidden Markov model (HMM) for pattern comparison. In most previous cases, a fixed-length moving window was employed to track dynamic data, and often failed to capture enough information for each fault and sometimes even deteriorated the diagnostic performance. A variable moving window, the length of which is modified with time, is introduced in this paper and case studies on the Tennessee Eastman process illustrate the potential of the proposed method.

  13. Sol-gel zirconia coating capillary microextraction on-line hyphenated with inductively coupled plasma mass spectrometry for the determination of Cr, Cu, Cd and Pb in biological samples.

    Science.gov (United States)

    Wu, Yiwei; Hu, Bin; Jiang, Zucheng; Feng, Yuqi; Lu, Peng; Li, Boyangzi

    2006-01-01

    A sol-gel zirconia coating was developed for the preconcentration/separation of trace Cr, Cu, Cd and Pb by capillary microextraction, and the adsorbed analytes were on-line eluted for detection using inductively coupled plasma mass spectrometry (ICP-MS). By immobilizing sol-gel zirconia on the inner surface of a fused-silica capillary, the sol-gel zirconia coating was simply prepared. Its adsorption properties, stability and the factors affecting the adsorption behaviors of Cr, Cu, Cd and Pb were investigated in detail. In the pH range from 7.8 to 10, the zirconia-coated capillary (35 cm x 0.15 mm) is selective towards Cr, Cu, Cd and Pb, and the analyzed ions could be desorbed quantitatively with 0.2 mL of 0.5 mol/L HNO(3) at a rate of 0.2 mL/min. With a consumption of 1.25 mL sample solution, an enrichment factor of 6.25, and detection limits (3sigma) of 9.9 pg/mL Cr, 17.9 pg/mL Cu, 4.5 pg/mL Cd and 3.7 pg/mL Pb were obtained. The precisions for nine replicate measurements of 1 ng/mL Cr, Cu, Cd and Pb were 4.9% Cr, 2.2% Cu, 2.0% Cd and 3.2% Pb (RSD), respectively. The proposed procedure has been applied to the determination of Cr, Cu, Cd and Pb in human urine, which was subjected to microwave-assisted digestion prior to analysis, and the recoveries for these elements were 89.2-101.8%. In order to validate the developed procedure, a NIES No.10-a Rice Flour-Unpolished certified reference material and a BCR No. 184 Bovine Muscle certified reference material were analyzed, and the results are in good agreement with the certified values. Copyright (c) 2006 John Wiley & Sons, Ltd.

  14. New Trends in on-line Marketing

    OpenAIRE

    Palkovič, Lukáš

    2011-01-01

    This bachelor thesis deals with new trend of internet marketing, it focuses especially on viral marketing. The theoretical part charasterizes the process of viral campaigns, furthermore deals with the components and aspects of on-line environment. Another separated chapter presents social networks, their place in viral marketing and at last but not least the viral video making process. The practical part contains different analyses of specific viral campaigns. The next and equally the last pa...

  15. Empirical likelihood estimation of discretely sampled processes of OU type

    Institute of Scientific and Technical Information of China (English)

    SUN ShuGuang; ZHANG XinSheng

    2009-01-01

    This paper presents an empirical likelihood estimation procedure for parameters of the discretely sampled process of Ornstein-Uhlenbeck type. The proposed procedure is based on the condi-tional characteristic function, and the maximum empirical likelihood estimator is proved to be consistent and asymptotically normal. Moreover, this estimator is shown to be asymptotically efficient under some tensity parameter can be exactly recovered, and we study the maximum empirical likelihood estimator with the plug-in estimated intensity parameter. Testing procedures based on the empirical likelihood ratio statistic are developed for parameters and for estimating equations, respectively. Finally, Monte Carlo simulations are conducted to demonstrate the performance of proposed estimators.

  16. Empirical likelihood estimation of discretely sampled processes of OU type

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    This paper presents an empirical likelihood estimation procedure for parameters of the discretely sampled process of Ornstein-Uhlenbeck type. The proposed procedure is based on the condi- tional characteristic function, and the maximum empirical likelihood estimator is proved to be consistent and asymptotically normal. Moreover, this estimator is shown to be asymptotically efficient under some mild conditions. When the background driving Lévy process is of type A or B, we show that the intensity parameter can be exactly recovered, and we study the maximum empirical likelihood estimator with the plug-in estimated intensity parameter. Testing procedures based on the empirical likelihood ratio statistic are developed for parameters and for estimating equations, respectively. Finally, Monte Carlo simulations are conducted to demonstrate the performance of proposed estimators.

  17. Adaptive Sampling for Learning Gaussian Processes Using Mobile Sensor Networks

    Directory of Open Access Journals (Sweden)

    Yunfei Xu

    2011-03-01

    Full Text Available This paper presents a novel class of self-organizing sensing agents that adaptively learn an anisotropic, spatio-temporal Gaussian process using noisy measurements and move in order to improve the quality of the estimated covariance function. This approach is based on a class of anisotropic covariance functions of Gaussian processes introduced to model a broad range of spatio-temporal physical phenomena. The covariance function is assumed to be unknown a priori. Hence, it is estimated by the maximum a posteriori probability (MAP estimator. The prediction of the field of interest is then obtained based on the MAP estimate of the covariance function. An optimal sampling strategy is proposed to minimize the information-theoretic cost function of the Fisher Information Matrix. Simulation results demonstrate the effectiveness and the adaptability of the proposed scheme.

  18. Dimensional Description of On-line Wear Debris Images for Wear Characterization

    Institute of Scientific and Technical Information of China (English)

    WU Tonghai; PENG Yeping; DU Ying; WANG Junqun

    2014-01-01

    As one of the most wear monitoring indicator, dimensional feature of individual particles has been studied mostly focusing on off-line analytical ferrograph. Recent development in on-line wear monitoring with wear debris images shows that merely wear debris concentration has been extracted from on-line ferrograph images. It remains a bottleneck of obtaining the dimension of on-line particles due to the low resolution, high contamination and particle’s chain pattern of an on-line image sample. In this work, statistical dimension of wear debris in on-line ferrograph images is investigated. A two-step procedure is proposed as follows. First, an on-line ferrograph image is decomposed into four component images with different frequencies. By doing this, the size of each component image is reduced by one fourth, which will increase the efficiency of subsequent processing. The low-frequency image is used for extracting the area of wear debris, and the high-frequency image is adopted for extracting contour. Second, a statistical equivalent circle dimension is constructed by equaling the overall wear debris in the image into equivalent circles referring to the extracted total area and premeter of overall wear debris. The equivalent circle dimension, reflecting the statistical dimension of larger wear debris in an on-line image, is verified by manual measurement. Consequently, two preliminary applications are carried out in gasoline engine bench tests of durability and running-in. Evidently, the equivalent circle dimension, together with the previously developed concentration index, index of particle coverage area (IPCA), show good performances in characterizing engine wear conditions. The proposed dimensional indicator provides a new statistical feature of on-line wear particles for on-line wear monitoring. The new dimensional feature conveys profound information about wear severity.

  19. DEVELOPMENT OF AN ON-LINE COAL WASHABILITY ANALYZER

    Energy Technology Data Exchange (ETDEWEB)

    J.D. Miller; C.L. Lin; G.H. Luttrell; G.T. Adel; Barbara Marin

    2001-06-26

    Washability analysis is the basis for nearly all coal preparation plant separations. Unfortunately, there are no on- line techniques for determining this most fundamental of all coal cleaning information. In light of recent successes at the University of Utah, it now appears possible to determine coal washability on-line through the use of x-ray computed tomography (CT) analysis. The successful development of such a device is critical to the establishment of process control and automated coal blending systems. In this regard, Virginia Tech, Terra Tek Inc., and U.S. coal producers have joined with the University of Utah and to undertake the development of an X-ray CT-based on- line coal washability analyzer with financial assistance from DOE. Each project participant brought special expertise to the project in order to create a new dimension in coal cleaning technology. The project involves development of appropriate software and extensive testing/evaluation of well-characterized coal samples from operating coal preparation plants. Data collected to date suggest that this new technology is capable of serving as a universal analyzer that can not only provide washability analysis, but also particle size distribution analysis, ash analysis, and perhaps pyritic sulfur analysis.

  20. DEVELOPMENT OF AN ON-LINE COAL WASHABILITY ANALYZER

    Energy Technology Data Exchange (ETDEWEB)

    J.D. Miller

    1999-09-30

    Washability analysis is the basis for nearly all coal preparation plant separations. Unfortunately, there are no on-line techniques for determining this most fundamental of all coal cleaning information. In light of recent successes at the University of Utah, it now appears possible to determine coal washability on-line through the use of x-ray computed tomography (CT) analysis. The successful development of such a device is critical to the establishment of process control and automated coal blending systems. In this regard, Virginia Tech, Terra Tek Inc., and several eastern coal companies have joined with the University of Utah and agreed to undertake the development of a x-ray CT-based on-line coal washability analyzer with financial assistance from DOE. The three-year project will cost $594,571, of which 33% ($194,575) will be cost-shared by the participants. The project involves development of appropriate software and extensive testing/evaluation of well-characterized coal samples from operating coal preparation plants. Each project participant brings special expertise to the project which is expected to create a new dimension in coal cleaning technology. Finally, it should be noted that the analyzer may prove to be a universal analyzer capable of providing not only washability analysis, but also particle size distribution analysis, ash analysis and perhaps pyritic sulfur analysis.

  1. Sample processing for earth science studies at ANTARES

    Science.gov (United States)

    Child, D.; Elliott, G.; Mifsud, C.; Smith, A. M.; Fink, D.

    2000-10-01

    AMS studies in earth sciences at ANTARES, ANSTO created a need for the processing of mineral and ice samples for 10Be, 26Al and 36Cl target preparation. Published procedures have been adapted to our requirements and improved upon where necessary. In particular, new methods to isolate Be with reproducible, high recoveries in the presence of excess Al and Ti were achieved. An existing elution scheme for a cation exchange column procedure was modified to incorporate the use of a 0.25 M H2SO4+0.015% H 2O2 washing step to elute the Ti peroxide complex formed. Problems with dust contamination in ice contributing to measured 10Be signals are also addressed and a procedure developed for its removal.

  2. CERN Video News on line

    CERN Multimedia

    2003-01-01

    The latest CERN video news is on line. In this issue : an interview with the Director General and reports on the new home for the DELPHI barrel and the CERN firemen's spectacular training programme. There's also a vintage video news clip from 1954. See: www.cern.ch/video or Bulletin web page

  3. Automated force volume image processing for biological samples.

    Directory of Open Access Journals (Sweden)

    Pavel Polyakov

    Full Text Available Atomic force microscopy (AFM has now become a powerful technique for investigating on a molecular level, surface forces, nanomechanical properties of deformable particles, biomolecular interactions, kinetics, and dynamic processes. This paper specifically focuses on the analysis of AFM force curves collected on biological systems, in particular, bacteria. The goal is to provide fully automated tools to achieve theoretical interpretation of force curves on the basis of adequate, available physical models. In this respect, we propose two algorithms, one for the processing of approach force curves and another for the quantitative analysis of retraction force curves. In the former, electrostatic interactions prior to contact between AFM probe and bacterium are accounted for and mechanical interactions operating after contact are described in terms of Hertz-Hooke formalism. Retraction force curves are analyzed on the basis of the Freely Jointed Chain model. For both algorithms, the quantitative reconstruction of force curves is based on the robust detection of critical points (jumps, changes of slope or changes of curvature which mark the transitions between the various relevant interactions taking place between the AFM tip and the studied sample during approach and retraction. Once the key regions of separation distance and indentation are detected, the physical parameters describing the relevant interactions operating in these regions are extracted making use of regression procedure for fitting experiments to theory. The flexibility, accuracy and strength of the algorithms are illustrated with the processing of two force-volume images, which collect a large set of approach and retraction curves measured on a single biological surface. For each force-volume image, several maps are generated, representing the spatial distribution of the searched physical parameters as estimated for each pixel of the force-volume image.

  4. Automated Force Volume Image Processing for Biological Samples

    Science.gov (United States)

    Duan, Junbo; Duval, Jérôme F. L.; Brie, David; Francius, Grégory

    2011-01-01

    Atomic force microscopy (AFM) has now become a powerful technique for investigating on a molecular level, surface forces, nanomechanical properties of deformable particles, biomolecular interactions, kinetics, and dynamic processes. This paper specifically focuses on the analysis of AFM force curves collected on biological systems, in particular, bacteria. The goal is to provide fully automated tools to achieve theoretical interpretation of force curves on the basis of adequate, available physical models. In this respect, we propose two algorithms, one for the processing of approach force curves and another for the quantitative analysis of retraction force curves. In the former, electrostatic interactions prior to contact between AFM probe and bacterium are accounted for and mechanical interactions operating after contact are described in terms of Hertz-Hooke formalism. Retraction force curves are analyzed on the basis of the Freely Jointed Chain model. For both algorithms, the quantitative reconstruction of force curves is based on the robust detection of critical points (jumps, changes of slope or changes of curvature) which mark the transitions between the various relevant interactions taking place between the AFM tip and the studied sample during approach and retraction. Once the key regions of separation distance and indentation are detected, the physical parameters describing the relevant interactions operating in these regions are extracted making use of regression procedure for fitting experiments to theory. The flexibility, accuracy and strength of the algorithms are illustrated with the processing of two force-volume images, which collect a large set of approach and retraction curves measured on a single biological surface. For each force-volume image, several maps are generated, representing the spatial distribution of the searched physical parameters as estimated for each pixel of the force-volume image. PMID:21559483

  5. On-line structure-lossless digital mammogram image compression

    Science.gov (United States)

    Wang, Jun; Huang, H. K.

    1996-04-01

    This paper proposes a novel on-line structure lossless compression method for digital mammograms during the film digitization process. The structure-lossless compression segments the breast and the background, compresses the former with a predictive lossless coding method and discards the latter. This compression scheme is carried out during the film digitization process and no additional time is required for the compression. Digital mammograms are compressed on-the-fly while they are created. During digitization, lines of scanned data are first acquired into a small temporary buffer in the scanner, then they are transferred to a large image buffer in an acquisition computer which is connected to the scanner. The compression process, running concurrently with the digitization process in the acquisition computer, constantly checks the image buffer and compresses any newly arrived data. Since compression is faster than digitization, data compression is completed as soon as digitization is finished. On-line compression during digitization does not increase overall digitizing time. Additionally, it reduces the mammogram image size by a factor of 3 to 9 with no loss of information. This algorithm has been implemented in a film digitizer. Statistics were obtained based on digitizing 46 mammograms at four sampling distances from 50 to 200 microns.

  6. Sequential-injection on-line preconcentration using chitosan resin functionalized with 2-amino-5-hydroxy benzoic acid for the determination of trace elements in environmental water samples by inductively coupled plasma-atomic emission spectrometry

    OpenAIRE

    2007-01-01

    A new chelating resin using chitosan as a base material was synthesized. Functional moiety of 2-amino-5-hydroxy benzoic acid (AHBA) was chemically bonded to the amino group of cross-linked chitosan (CCTS) through the arm of chloromethyloxirane (CCTS-AHBA resin). Several elements, such as Ag, Be, Cd, Co, Cu, Ni, Ph, U, V, and rare earth elements (REEs), could be adsorbed on the resin. To use the resin for on-line pretreatment, the resin was packed in a mini-column and installed into a sequenti...

  7. Hyphenating multisyringe flow injection lab-on-valve analysis with atomic fluorescence spectrometry for on-line bead-injection preconcentration and determination of trace levels of hydride-forming elements in environmental samples

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald;

    2006-01-01

    of the functional moieties, so that maximum benefit can be taken from the application of the bead renewal strategy. The proposed procedure is characterized by a high tolerance to metal species and interfering hydride forming elements. In fact, ratios of Se(IV) to As ≤ 5000 and Sb(V) to As ≤ 500 are tolerated...... feasible by interfacing the micromachined LOV-module with AFS by a multisyringe flowing stream network for on-line post column derivatization of the eluate aimed at the generation of hydride species. The potential of this new hyphenated technique for environmental assays was ascertained via...

  8. Sampling Designs in Qualitative Research: Making the Sampling Process More Public

    Science.gov (United States)

    Onwuegbuzie, Anthony J.; Leech, Nancy L.

    2007-01-01

    The purpose of this paper is to provide a typology of sampling designs for qualitative researchers. We introduce the following sampling strategies: (a) parallel sampling designs, which represent a body of sampling strategies that facilitate credible comparisons of two or more different subgroups that are extracted from the same levels of study;…

  9. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  10. On-Line Wavelength Calibration of Pulsed Laser for CO2 Differential Absorption LIDAR

    Science.gov (United States)

    Xiang, Chengzhi; Ma, Xin; Han, Ge; Liang, Ailin; Gong, Wei

    2016-06-01

    Differential absorption lidar (DIAL) remote sensing is a promising technology for atmospheric CO2 detection. However, stringent wavelength accuracy and stability are required in DIAL system. Accurate on-line wavelength calibration is a crucial procedure for retrieving atmospheric CO2 concentration using the DIAL, particularly when pulsed lasers are adopted in the system. Large fluctuations in the intensities of a pulsed laser pose a great challenge for accurate on-line wavelength calibration. In this paper, a wavelength calibration strategy based on multi-wavelength scanning (MWS) was proposed for accurate on-line wavelength calibration of a pulsed laser for CO2 detection. The MWS conducted segmented sampling across the CO2 absorption line with appropriate number of points and range of widths by using a tunable laser. Complete absorption line of CO2 can be obtained through a curve fitting. Then, the on-line wavelength can be easily found at the peak of the absorption line. Furthermore, another algorithm called the energy matching was introduced in the MWS to eliminate the backlash error of tunable lasers during the process of on-line wavelength calibration. Finally, a series of tests was conducted to elevate the calibration precision of MWS. Analysis of tests demonstrated that the MWS proposed in this paper could calibrate the on-line wavelength of pulsed laser accurately and steadily.

  11. Clean Air OnLine

    Energy Technology Data Exchange (ETDEWEB)

    Finney, D. [Environment Canada, Gatineau, PQ (Canada). Air Pollution Prevention Directorate

    2004-04-07

    This presentation describes Clean Air OnLine, a multi-tiered website dedicated to providing Canadians with information on air quality. The website is under development to support action to reduce air emissions, demonstrate the links between air emissions and environmental impacts, and enhance the understanding of sustainable community development issues such as health, energy, and urban sprawl. Partners in the Clean Air OnLine (CAOL) initiative include Environment Canada and the Clean Air Partnership which includes the Greater Toronto Area pilot project. The audience for CAOL includes municipal decision makers, local decision makers, community leaders, and the general public. The project provides Canadians with air pollution contextual information on pollution sources, pollutants, and related issues. It also provides information on health, environmental and economic impacts and the interrelationships with climate change issues and energy use. tabs., figs.

  12. THE SAMPLING PROCESS IN THE FINANCIAL AUDIT .TECHNICAL PRACTICE APPROACH

    Directory of Open Access Journals (Sweden)

    GRIGORE MARIAN

    2014-07-01

    “Audit sampling” (sampling assumes appliancing audit procedures for less than 100% of the elements within an account or a trasaction class balance, such that all the samples will be selected. This will allow the auditor to obtain and to evaluate the audit evidence on some features for the selected elements, in purpose to assist or to express a conclusion regardind the population within the sample was extracted. The sampling in audit can use both a statistical or a non-statistical approach. (THE AUDIT INTERNATIONAl STANDARD 530 –THE SAMPLING IN AUDIT AND OTHER SELECTIVE TESTING PROCEDURES

  13. THE SAMPLING PROCESS IN THE FINANCIAL AUDIT .TECHNICAL PRACTICE APPROACH

    Directory of Open Access Journals (Sweden)

    Cardos Vasile-Daniel

    2014-12-01

    “Audit sampling” (sampling assumes appliancing audit procedures for less than 100% of the elements within an account or a trasaction class balance, such that all the samples will be selected. This will allow the auditor to obtain and to evaluate the audit evidence on some features for the selected elements, in purpose to assist or to express a conclusion regardind the population within the sample was extracted. The sampling in audit can use both a statistical or a non-statistical approach. (THE AUDIT INTERNATIONAl STANDARD 530 –THE SAMPLING IN AUDIT AND OTHER SELECTIVE TESTING PROCEDURES

  14. Recent Results of the Investigation of a Microfluidic Sampling Chip and Sampling System for Hot Cell Aqueous Processing Streams

    Energy Technology Data Exchange (ETDEWEB)

    Julia Tripp; Jack Law; Tara Smith

    2013-10-01

    A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and microfluidics sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The microfluidic-based robotic sampling system’s mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of microfluidic sampling chips.

  15. Algorithms for semi on-line multiprocessor scheduling problems

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In the classical multiprocessor scheduling problems, it is assumed that the problems are considered in off-line or on-line environment. But in practice, problems are often not really off-line or on-line but somehow in between. This means that, with respect to the on-line problem, some further information about the tasks is available, which allows the improvement of the performance of the best possible algorithms. Problems of this class are called semi on-line ones. The authors studied two semi on-line multiprocessor scheduling problems, in which, the total processing time of all tasks is known in advance, or all processing times lie in a given interval. They proposed approximation algorithms for minimizing the makespan and analyzed their performance guarantee. The algorithms improve the known results for 3 or more processor cases in the literature.

  16. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H.; Saerme, T.; Kotiaho, T.; Hiissa, T.; Savolahti, P.; Komppa, V. [VTT Chemical Technology, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  17. Research of on-line detection system for power capacitor

    Science.gov (United States)

    Yao, Junda; Qian, Zheng; Yu, Hao; Xia, Jiuyun

    2016-01-01

    The hidden danger exists in the power capacitor of power system due to long-time operation under the environment of high voltage. Thus, it is possible to induce serious fault, and the on-line detection system is urgently required. In this paper, two methods of the on-line detection system are compared in order to realize the better real-time condition detection. The first method is based on the STM microprocessor with an internal 12 bit A/D converter, which converts analog signals which is arrived from the sample circuit into digital signals, and then the FFT algorithm is used to accomplish the measurement of the voltage and current values of the capacitor. The second method is based on the special electric energy metering IC, which can obtain RMS (Root Mean Square) of voltage and current by processing the sampled data of the voltage and current, and store RMS of voltage and current in its certain registers. The operating condition of the capacitor can be obtained after getting the values of voltage and current. By comparing the measuring results of two methods, the second method could achieve a higher measurement accuracy and more simple construction.

  18. Single photon ionization (SPI) via incoherent VUV-excimer light: robust and compact time-of-flight mass spectrometer for on-line, real-time process gas analysis.

    Science.gov (United States)

    Mühlberger, F; Wieser, J; Ulrich, A; Zimmermann, R

    2002-08-01

    Fast on-line detection of organic compounds from complex mixtures, such as industrial process gas streams, require selective and sensitive analytical methods. One feasible approach for this purpose is the use of mass spectrometry (MS) with a selective and soft (fragment-free) ionization technique, such as chemical ionization (CI) or photo ionization (PI). Single photon ionization (SPI) with vacuum ultraviolet (VUV) light is a particularly sof tionization technique, well-suited for detection of both aromatic and aliphatic species. Problematic, however, is the generation of the VUV light. In general, the vacuum ultraviolet (VUV) light sources for SPI-MS are based either on lasers (e.g., 118-nm radiation generated by frequency-tripling of the third harmonic of a Nd:YAG laser) or on conventional VUV lamps, such as deuterium lamps. Althoughthe laser-based techniques are very sophisticated and expensive, the conventional lamps have serious drawbacks regarding their optical parameters, such as low-output power, low spectral power density, and broad emission bands. In this work, a novel excimer VUV light source, in which an electron beam is used to form rare gas excimer species, is used. The excimer VUV light sourceproduces brilliant and intense VUV light. The novel VUV light source was coupled to a compact and mobile time-of-flight mass spectrometer (TOFMS). A special interface design, including optical (VUV optics) as well as electronic measures (e.g., pulsed ion extraction) was realized. The use of the excimer VUV lamp for SPI will allow the realization of very compact, rugged, and sensitive SPI-TOFMS devices, which preferably will be adapted for process analytical application or monitoring issues (e.g., chemical warfare detection). The excimer VUV-lamp technology delivers VUV light with a good beam quality and high-output power at low costs. Furthermore, it allows changing the emitted wavelength as well as the bandwidth of the excimer VUV lamp in t he 100-200-nm region

  19. Optimization of enrichment processes of pentachlorophenol (PCP) from water samples

    Institute of Scientific and Technical Information of China (English)

    LI Ping; LIU Jun-xin

    2004-01-01

    The method of enriching PCP (pentachlorophenol) from aquatic environment by solid phase extraction (SPE) was studied.Several factors affecting the recoveries of PCP, including sample pH, eluting solvent, eluting volume and flow rate of water sample, were optimized by orthogonal array design(OAD). The optimized results were sample pH 4; eluting solvent, 100% methanol; eluting solvent volume, 2 mi and flow rate of water sample, 4 mi/min. A comparison is made between SPE and liquid-liquid extraction(LLE) method. The recoveries of PCP were in the range of 87.6 % 133.6 % and 79 %- 120.3 % for S PE and LLE, respectively. Important advantages of the SPE compared with the LLE include the short extraction time and reduced consumption of organic solvents. SPE can replace LLE for isolating and concentrating PCP from water samples.

  20. Academic Design of On-line Radiation Monitoring Instrument for Gaseous Radioactive Waste Processing System%核电站废气处理系统在线辐射监测仪理论设计

    Institute of Scientific and Technical Information of China (English)

    王洪; 刘春雨; 罗鹏; 陈祥磊

    2013-01-01

    针对核电站废气处理系统对所排含氢废气的放射性监测要求,提出了一种在线监测方案,有效地解决了废气处理系统含氢废气中85 Kr、133 Xe核素放射性监测的问题。并利用模拟程序对监测仪的探测效率、环境γ本底影响等进行了蒙特卡罗模拟计算,为设备的研制生产提供了重要的理论参考和依据。计算结果表明:采用尺寸为φ15 mm ×0.5 mm的圆形薄片塑料闪烁体,基于在线监测方案,在理论设计上可满足AP1000核电站废气处理系统对所排含氢废气的放射性监测要求,在γ环境本底小于10μGy/h条件下无需增加铅屏蔽体。%According to the radioactivity monitoring requirements for exhaust air with the hydrogen waste gas from the waste gas processing system of the nuclear power plant , a kind of on-line monitoring scheme is de-signed to efficiently solve the problem of radiation monitoring of 85 Kr and 133 Xe in waste gas containing hydro-gen.The detection efficiency and the influences of the environmental gamma background for the monitor have been calculated by Monte Carlo code .Thereby , important theoretical references are provided for the equipment development and production .The calculated results show that plastic scintillator with the size of φ10 ×0.5mm that is based on the on -line monitoring scheme fully meets the radioactivity monitoring requirements for exhaust air with the hydrogen waste gas from the waste gas processing system of AP 1000 nuclear power plant .If the gamma environmental background is smaller than 10μGy/h, the lead shielding is not needed .

  1. sampling plans for monitoring quality control process at a plastic ...

    African Journals Online (AJOL)

    Dr Obe

    managing these -activities in an intercultural environment will be of increasing ... adoption of new managerial concepts and .techniques among ... sample for both monitoring and quality control purposes. Prybrutok, et al. 7 observed that the.

  2. Technical Evaluation of Sample-Processing, Collection, and Preservation Methods

    Science.gov (United States)

    2014-07-01

    this study included both filter-based and bead-based DNA isolation technologies. In addition to this initial evaluation, soil samples ( clay and...precipitation. The resultant DNA pellet was resuspended in 35 µL of TE buffer. 8. Epicentre SoilMaster DNA Extraction Kit; Epicentre Biotechnologies...precipitated DNA was pelleted and resuspended in 35 µL TE buffer. 9. IT 1-2-3 Platinum Path Sample-Purification Kit; BioFire Diagnostics, Inc

  3. CLASSIFICATION OF BAUMANN SAMPLES THROUGH DIGITAL IMAGE PROCESSING

    Directory of Open Access Journals (Sweden)

    Luciene Coelho Lopez Queiroz

    2013-06-01

    Full Text Available The method Baumann, or sulphur print as it is also known, is one of the tools used to evaluate the operating conditions of continuous casting machine and quality control of material produced. The internal defects analyzed in sulphur print are traditionally classified manually by comparing sample results with predefined patterns. This paper presents an alternative to the traditional classification of internal defects, making use of digital images of samples generated during Baumann method.

  4. High frequency sampling of a continuous-time ARMA process

    CERN Document Server

    Brockwell, Peter J; Klüppelberg, Claudia

    2011-01-01

    Continuous-time autoregressive moving average (CARMA) processes have recently been used widely in the modeling of non-uniformly spaced data and as a tool for dealing with high-frequency data of the form $Y_{n\\Delta}, n=0,1,2,...$, where $\\Delta$ is small and positive. Such data occur in many fields of application, particularly in finance and the study of turbulence. This paper is concerned with the characteristics of the process $(Y_{n\\Delta})_{n\\in\\bbz}$, when $\\Delta$ is small and the underlying continuous-time process $(Y_t)_{t\\in\\bbr}$ is a specified CARMA process.

  5. Total on-line purchasing system (TOPS)

    Energy Technology Data Exchange (ETDEWEB)

    Collins, N.

    1995-11-01

    The Information Management Division (IMD) at LLNL is developing a new purchasing system for the Procurement Department. The first major development of this new system is called, {open_quotes}Total On-Line Purchasing System{close_quotes} (TOPS). TOPS will help speed up the requisitioning process by having requisitions electronically entered by requesters and electronically sent to buyers to be put on Purchase Orders. The new purchasing system will use Electronic Commerce (EC)/Electronic Data Interchange (EDI), to help increase transaction flows for shipping notices, RFQs, Quotes, Purchase Orders, and Invoices. ANSI X.12 is the EDI standard that this new EC will use.

  6. Development of sampling systems and special analyses for pressurized gasification processes; Paineistettujen kaasutusprosessien naeytteenottomenetelmien ja erityisanalytiikan kehittaeminen

    Energy Technology Data Exchange (ETDEWEB)

    Staahlberg, P.; Oesch, P.; Leppaemaeki, E.; Moilanen, A.; Nieminen, M.; Korhonen, J. [VTT Energy, Espoo (Finland)

    1996-12-01

    The reliability of sampling methods used for measuring impurities contained in gasification gas were studied, and new methods were developed for sampling and sample analyses. The aim of the method development was to improve the representativeness of the samples and to speed up the analysis of gas composition. The study focused on tar, nitrogen and sulphur compounds contained in the gasification gas. In the study of the sampling reliability, the effects of probe and sampling line materials suitable for high temperatures and of the solids deposited in the sampling devices on gas samples drawn from the process were studied. Measurements were carried out in the temperature range of 250 - 850 deg C both in real conditions and in conditions simulating gasification gas. The durability of samples during storage was also studied. The other main aim of the study was to increase the amount of quick-measurable gas components by developing on-line analytical methods based on GC, FTIR and FI (flow injection) techniques for the measurements of nitrogen and sulphur compounds in gasification gas. As these methods are suitable only for the gases that do not contain condensing gas components disturbing the operation of analysers (heavy tar compounds, water), a sampling system operating in dilution principle was developed. The system operates at high pressures and temperatures and is suitable for gasification gases containing heavy tar compounds. The capabilities of analysing heavy tar compounds (mole weight >200 g mol) was improved by adding the amount of compounds identified and calibrated by model substances and by developing analytical methods based on the high-temperature-GC analysis and the thermogravimetric method. (author)

  7. Signal sampling techniques for data acquisition in process control

    NARCIS (Netherlands)

    Laan, Marten Derk van der

    1995-01-01

    In computing sytems employed for data acquisition and process control, communication with the controlled processes is mainly taking place via analog signal lines. In this situation, the quality of data acquired by A/D-converters and the generation of analog control signals by D/A-converters is of

  8. Signal sampling techniques for data acquisition in process control

    OpenAIRE

    Laan, Marten Derk van der

    1995-01-01

    In computing sytems employed for data acquisition and process control, communication with the controlled processes is mainly taking place via analog signal lines. In this situation, the quality of data acquired by A/D-converters and the generation of analog control signals by D/A-converters is of major importance for the overall performance of a system. ... Zie: Summary

  9. Signal sampling techniques for data acquisition in process control

    NARCIS (Netherlands)

    Laan, Marten Derk van der

    1995-01-01

    In computing sytems employed for data acquisition and process control, communication with the controlled processes is mainly taking place via analog signal lines. In this situation, the quality of data acquired by A/D-converters and the generation of analog control signals by D/A-converters is of ma

  10. Full quantification of selenium species by RP and AF-ICP-qMS with on-line isotope dilution in serum samples from mercury-exposed people supplemented with selenium-enriched yeast

    DEFF Research Database (Denmark)

    Li, Yu-Feng; Hu, Liang; Li, Bai

    2011-01-01

    Accurate determination of selenium (Se) species in biological samples is a critical issue because Se commonly occurs at low levels and in diverse species. The method for the full quantification of Se species in serum samples was proposed through combined ion-pair reverse-phase (RP) chromatography...

  11. 多核处理器上的并行联机分析处理算法研究%Parallel On-Line Analysis Processing Algorithms Research on Multi-Core CPUs

    Institute of Scientific and Technical Information of China (English)

    周国亮; 王桂兰; 朱永利

    2013-01-01

    Computer hardware technology has greatly developed, especially large memory and multi-core, but the algorithm efficiency dose not improve with the development of hardware. The fundamental reason is the insufficient utilization of CPU cache and the limitation of single-thread programming. In the field of OLAP (on-line analysis processing), data cube computation is an important and time-consuming operation, so how to improve the perfor-mance of data cube computation is a difficult research point in this field. Based on the characteristics of multi-core CPUs, this paper proposes two parallel algorithms, MT-Multi-Way (multi-threading multi-way) and MT-BUC (multi-threading bottom-up computation), which utilize data partition and multi-thread cooperation. All these algo-rithms avoid cache contentions between threads and keep loading balance, so obtain near-linear speedup. Based on these algorithms, this paper suggests one unified framework for cube computation on multi-core CPUs, including how to partition data and resolve recursive program on multi-core CPUs for guiding cube computation parallelization.

  12. Sampling from Determinantal Point Processes for Scalable Manifold Learning.

    Science.gov (United States)

    Wachinger, Christian; Golland, Polina

    2015-01-01

    High computational costs of manifold learning prohibit its application for large datasets. A common strategy to overcome this problem is to perform dimensionality reduction on selected landmarks and to successively embed the entire dataset with the Nyström method. The two main challenges that arise are: (i) the landmarks selected in non-Euclidean geometries must result in a low reconstruction error, (ii) the graph constructed from sparsely sampled landmarks must approximate the manifold well. We propose to sample the landmarks from determinantal distributions on non-Euclidean spaces. Since current determinantal sampling algorithms have the same complexity as those for manifold learning, we present an efficient approximation with linear complexity. Further, we recover the local geometry after the sparsification by assigning each landmark a local covariance matrix, estimated from the original point set. The resulting neighborhood selection .based on the Bhattacharyya distance improves the embedding of sparsely sampled manifolds. Our experiments show a significant performance improvement compared to state-of-the-art landmark selection techniques on synthetic and medical data.

  13. Communication Barriers in Quality Process: Sakarya University Sample

    Science.gov (United States)

    Yalcin, Mehmet Ali

    2012-01-01

    Communication has an important role in life and especially in education. Nowadays, lots of people generally use technology for communication. When technology uses in education and other activities, there may be some communication barriers. And also, quality process has an important role in higher education institutes. If a higher education…

  14. Gap processing for adaptive maximal Poisson-disk sampling

    KAUST Repository

    Yan, Dongming

    2013-09-01

    In this article, we study the generation of maximal Poisson-disk sets with varying radii. First, we present a geometric analysis of gaps in such disk sets. This analysis is the basis for maximal and adaptive sampling in Euclidean space and on manifolds. Second, we propose efficient algorithms and data structures to detect gaps and update gaps when disks are inserted, deleted, moved, or when their radii are changed.We build on the concepts of regular triangulations and the power diagram. Third, we show how our analysis contributes to the state-of-the-art in surface remeshing. © 2013 ACM.

  15. Automated sequential injection-microcolumn approach with on-line flame atomic absorption spectrometric detection for implementing metal fractionation schemes of homogeneous and non-homogeneous solid samples of environmental interest

    DEFF Research Database (Denmark)

    Chomchoei, Roongrat; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    An automated sequential injection (SI) system incorporating a dual-conical microcolumn is proposed as a versatile approach for the accommodation of both single and sequential extraction schemes for metal fractionation of solid samples of environmental concern. Coupled to flame atomic absorption...... spectrometric detection and used for the determination of Cu as a model analyte, the potentials of this novel hyphenated approach are demonstrated by the ability of handling up to 300 mg sample of a nonhomogeneous sewage amended soil (viz., CRM 483). The three steps of the endorsed Standards, Measurements...

  16. Order–disorder–reorder process in thermally treated dolomite samples

    DEFF Research Database (Denmark)

    Zucchini, Azzurra; Comodi, Paola; Katerinopoulou, Anna;

    2012-01-01

    A combined powder and single-crystal X-ray diffraction analysis of dolomite [CaMg(CO3)2] heated to 1,200oC at 3 GPa was made to study the order–disorder–reorder process. The order/disorder transition is inferred to start below 1,100oC, and complete disorder is attained at approximately 1,200o...

  17. Automated sampling and data processing derived from biomimetic membranes

    DEFF Research Database (Denmark)

    Perry, Mark; Vissing, Thomas; Boesen, P.

    2009-01-01

    Recent advances in biomimetic membrane systems have resulted in an increase in membrane lifetimes from hours to days and months. Long-lived membrane systems demand the development of both new automated monitoring equipment capable of measuring electrophysiological membrane characteristics and new....... The combined solution provides a cost efficient and fast way to acquire, process and administrate large amounts of voltage clamp data that may be too laborious and time consuming to handle manually....

  18. Implementation of suitable flow injection/sequential injection on-line sample pretreatment schemes. Separation and preconcentration procedures for the determination of trace metal concentrations by ETAAS and/or ICPMS

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Wang, Jianhua

    Despite their excellent analytical chemical capacities, ETAAS and ICPMS, nevertheless, often require suitable pretreatment of the sample material in order to obtain the necessary sensitivity and selectivity. Either in order to separate/preconcentrate the analyte material, or because of the presen...

  19. Incremental Sampling Methodology (ISM). Part 2, Section 6: Laboratory Processing

    Science.gov (United States)

    2012-03-01

    Pick the wrong option • Poor and unknown bias 4 Include Lab Processing in Project Planning Lab ITRC, ISM-1, Section 6.1.1 5 Define the Analytes...Disaggregation and sieving • Nugget effect expected to be small  Contaminant exposure sprayed as a liquid  Mill • Puck mill  Comparison study planned 16 Lab...Subsampling 22 Dry Splitting Options  Rotary sectorial splitter ITRC, ISM-1, Section 6.2.2.7 23 Subsampling Options  2-Dimensional Japanese Slabcake

  20. Parametric estimation of discretely sampled Gamma-OU processes

    Institute of Scientific and Technical Information of China (English)

    ZHANG Shibin; ZHANG Xinsheng; SUN Shuguang

    2006-01-01

    The stationary Gamma-OU processes are recommended to be the volatility of the financial assets. A parametric estimation for the Gamma-OU processes based on the discrete observations is considered in this paper. The estimator of an intensity parameter λ and its convergence result are given, and the simulations show that the estimation is quite accurate. Assuming that the parameter λ is estimated, the maximum likelihood estimation of shape parameter c and scale parameter α, whose likelihood function is not explicitly computable, is considered. By means of the Gaver-Stehfest algorithm, we construct an explicit sequence of approximations to the likelihood function and show that it converges the true (but unkown) one. Maximizing the sequence results in an estimator that converges to the true maximum likelihood estimator and the approximation shares the asymptotic properties of the true maximum likelihood estimator. Some simulation experiments reveal that this method is still quite accurate in most of rational situations for the background of volatility.

  1. A Brief Introduction of On-Line Analytical Processing Based On Data Warehouse of Gas Card Data%面向加油卡数据仓库的联机分析处理的探讨

    Institute of Scientific and Technical Information of China (English)

    陆瑞明

    2015-01-01

    对于石油销售企业来说,每天企业下属各加油站加油卡的使用都在不断产生交易数据,如何对这些海量数据进行有效挖掘处理成了目前业界的研究热点。本文则为关于加油卡大数据应用提供了一种业界最流行的方法:首先搭建一个数据存储系统,称为数据仓库,能存储海量历史数据;然后,在数据仓库的基础上,引入联机分析处理(OLAP),根据业务部门的不同需求给出各自所需的结果,也供企业高层管理人员进行决策使用。%Transaction data from gas cards are being created and collected continuously everyday at every gas station, which makes it very important to study on how to manage those massive data efficiently. This paper proposes a popular application of big data analysis on massive gas card transaction data: at first, building a data storage system, called Data Warehouse, to store large amounts of historical transaction data; secondly, introducing the On-Line Analytical Processing (OLAP) based on the Data Warehouse. OLAP allows users to extract different kinds of information from the raw data that meets their own needs for either research studies or enterprise decision making purpose.

  2. 21 CFR 211.110 - Sampling and testing of in-process materials and drug products.

    Science.gov (United States)

    2010-04-01

    ... PHARMACEUTICALS Production and Process Controls § 211.110 Sampling and testing of in-process materials and drug... production process, e.g., at commencement or completion of significant phases or after storage for long... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sampling and testing of in-process materials...

  3. On-line micro column preconcentration system based on amino bimodal mesoporous silica nanoparticles as a novel adsorbent for removal and speciation of chromium (III, VI) in environmental samples.

    Science.gov (United States)

    Shirkhanloo, Hamid; Khaligh, Aisan; Golbabaei, Farideh; Sadeghi, Zargham; Vahid, Amir; Rashidi, Alimorad

    2015-01-01

    Chromium (VI) has toxic and carcinogenic effects. So, determination and speciation of chromium in environmental samples is very important in view of health hazards. In this study, solid phase extraction (SPE) based on bulky amine-functionalized bimodal mesoporous silica nanoparticles (NH2-UVM-7) as a novel nanoadsorbent was applied for preconcentration and speciation of chromium (III, VI) in water samples. UVM-7 was synthesized via atrane route and subsequently functionalized with amino silane via grafting method. In SPE procedure, polymer tubing as a micro-column was filled with NH2-UVM-7 adsorbent. Preconcentration and speciation of Cr (III) and Cr (VI) ions with NH2-UVM-7 were obtained in water samples due to the fact that only Cr (VI) ions can be complexed with-NH2 groups at optimized pH. Finally, chromium concentration was determined by flame atomic absorption spectrometry (F-AAS). TEM, XRD, and SEM results confirmed the beneficial properties of NH2-UVM-7 as the adsorbent for chromium extraction. Under the optimal conditions, linear calibration curve, detection limit and preconcentration factor were obtained 6-320 μg/ L, 1.2 μg/L and 66.7, respectively (RSD < 5 %). The efficiency of nanoadsorbent for preconcentration and extraction of Cr (VI) was 96 %, whereas it was less than 5 % for Cr (III). The developed NH2-UVM7-based SPE/F-AAS method has enough sensitively and simplicity for speciation and determination of Cr (VI) and Cr (III) ions in real water samples. Good recoveries, with low detection limits and good preconcentration factors are the main advantages of this procedure.

  4. Simultaneous analysis of theanine, chlorogenic acid, purine alkaloids and catechins in tea samples with the help of multi-dimension information of on-line high performance liquid chromatography/electrospray-mass spectrometry.

    Science.gov (United States)

    Zhu, Xiaolan; Chen, Bo; Ma, Ming; Luo, Xubiao; Zhang, Fei; Yao, Shouzhuo; Wan, Zutian; Yang, Dajin; Hang, Hongwei

    2004-02-18

    A reverse phase high performance liquid chromatography (RP-HPLC) separation coupled with photo diode array detection (DAD) and electrospray ionization mass spectrometry (ESI-MS) detection was established for the analyzing of multiple bioactive compounds in tea and tea extracts. Theanine, chlorogenic acid, purine alkaloids and catechins were identified with authentic standard compounds and with MS-spectra. The content of theanine and catechins was measured by employing DAD and caffeine, chlorogenic acid, theobromine and theopylline by protonated molecular ion on selective ion recording (SIR) mode. The unity of LC/ESI-MS provides more qualitative and quantitative information comparing with general HPLC in the analysis of multi-components in tea, and complex extraction or sample pretreatment is unnecessary. The chromatogram acquired by using this method can be used as a bioactive components fingerprint for the quality control of tea and its extracts. With the help of multi-dimension information of HPLC-DAD-ESIMS, the compounds owning different chemical structure such as amino acid, catechins, etc. in tea and its extracts could be identified and determined in one run successfully.

  5. An on-line remote supervisory system for microparticles based on image analysis

    Science.gov (United States)

    Liu, Wei-Hua; Jiang, Ming-Shun; Sui, Qing-Mei

    2011-11-01

    A new on-line remote particle analysis system based on image processing has been developed to measure microparticles. The system is composed of particle collector sensor (PCS), particle image sensor (PIS), image remote transmit module and image processing system. Then some details of image processing are discussed. The main advantage of this system is more convenient in particle sample collection and particle image acquisition. The particle size can be obtained using the system with a deviation abot less than 1 μm, and the particle number can be obtained without deviation. The developed system is also convenient and versatile for other analyses of microparticle for academic and industrial application.

  6. Independent Sampling vs Interitem Dependencies in Whole Report Processing: Contributions of Processing Architecture and Variable Attention.

    Science.gov (United States)

    Busey, Thomas A.; Townsend, James T.

    2001-04-01

    All current models of visual whole report processing assume perceptual independence among the displayed items in which the perceptual processing of individual items is not affected by other items in the display. However, models proposed by Townsend (1981, Acta Psychologica 47, 149-173), Shibuya and Bundesen (1988, Journal of Experimental Psychology: Human Perception and Performance 14, 591-600), and Bundesen (1990, Psychological Review 97, 523-547) contain postperceptual buffers that must predict negative dependencies. The perceptual-independence assumption forms what we term the modal model class. A recent example of a model that assumes perceptual independence is the Independent Sampling Model of Loftus, Busey, and Senders (1993, Perception and Psychophysics 54, 535-554). The fundamental independence assumption has only been directly tested once before, where tests revealed no dependencies except those produced by guessing. The present study tests the independence assumption using several different statistics and, contrary to most extant models of whole report, finds significant positive dependence. Poisson models do predict a positive dependence and we develop a succinctly parameterized version, the Weighted Path Poisson Model, which allows the finishing order to be a weighted probabilistic mechanism. However, it does not predict the data quite as well as a new model, the Variable Attention Model, which allows independence within trials (unlike the Poisson models). This model assumes that attention (or, potentially, other aspects such as signal quality) varies widely across trials, thus predicting an overall positive dependence. Intuitions for and against the competing models are discussed. In addition, we show, through mimicking formulae, that models which contain the proper qualitative type of dependence structure can be cast in either serial or parallel form. Copyright 2001 Academic Press.

  7. QC of sampling processes- a first overview: from field to test portion.

    Science.gov (United States)

    Esbensen, Kim H; Ramsey, Charles A

    2015-01-01

    Quality control (QC) is a systematic approach for estimating and minimizing significant error contributions to the measurement uncertainty from the full sampling and analysis process. Many types of QC measures can be implemented; the three dealt with here are primary sampling reproducibility, sample processing reproducibility, and contamination. Sampling processes can be subject to QC by applying a replication experiment, used either from the top by replication of the entire sampling/ preparation/analysis process, or in a hierarchical fashion successively at each subsequent sampling stage. The analytical repeatability is necessarily always included in either alternative. The replication experiment results in a quality index, the Relative Sampling Variability, which is used to assess the total error associated with the full field-to-analysis pathway. Contamination can occur at essentially all locations in the sampling regimen in the food/feed realm, affecting sample containers, sampling tools, sample processing equipment, environmental conditions, and sampling personnel. QC events to determine contamination should always be included where appropriate, but is of most concern for low concentration and/or volatile analytes. It is also of key importance in the development of new sampling protocols or carried-over protocols intended for use on new types of materials/lots than the ones for which they were originally developed. We here establish a first practical framework for QC as applied to the sampling context.

  8. On-line Monitoring of Extraction Process for Schisandrachinensis Using Near-Infrared Spectroscopy%基于近红外光谱的五味子提取过程在线检测方法研究

    Institute of Scientific and Technical Information of China (English)

    仲怿; 潘万芳; 朱捷强; 范骁辉; 康立源; 李正

    2014-01-01

    目的:利用近红外(NIR)光谱法,建立定量模型,实现五味子提取过程中关键指标的快速检测。方法:在线采集五味子提取液的近红外光谱,以高效液相色谱法和差重法获取参照,采用最小二乘回归法(PLSR)分别建立五味子醇甲、果糖、葡萄糖和可溶性固形物的定量模型。结果:定量模型的校正集相关系数R、校正均方根误差RMSEC、预测均方根误差RMSEP分别为:五味子醇甲0.99792、1.41、8.76,果糖0.99246、0.0919、0.333,葡萄糖0.99371、0.0954、0.448,可溶性固形物0.98723、3.07、11.2。结论:该方法快速、便捷,结果准确,适用于五味子提取过程的快速检测。%It is the objective of this study to establish quantitative models to detect quality indicators rapidly during theextraction process of Schisandrachinensis using using near-infrared (NIR) spectroscopy. NIR spectrum was collected on-line and PLSR models were developed for the contents of schisandrin , fructose, glucose and soluble solids, which were measured with HPLC and weight loss methods. For the cross validation of contents of schisandrin, fructose, glucose and soluble solids, the correlation coefficients were 0.99792, 0.99246, 0.99371 and 0.98723; RMSEC were 1.41, 0.0919, 0.0954 and 3.07; RMSEP were 8.76, 0.333, 0.448 and 11.2, respectively. In conclusion, NIR models were developed successfully to determine the quality indicators including the contents of schisandrin, fructose, glucose and soluble solids rapidly and accurately.

  9. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  10. Are on-line currencies virtual banknotes?

    OpenAIRE

    Stephen F. Quinn; William Roberds

    2003-01-01

    The history of money is marked by innovations that have expanded the role of "inside money"-money created by the private sector. For instance, the past few years have seen the development of several types of on-line payment arrangements, some of which have been dubbed "on-line currencies." ; This article examines the likely success or failure of on-line currencies by means of a historical analogy. The discussion compares the introduction of on-line currencies to the debut of the bearer bankno...

  11. Metrological Characterization of an Improved DSP-Based On-line Integrator for Magnetic Measurements at CERN

    CERN Document Server

    Arpaia, P; Spiezia, G

    2007-01-01

    An improved on-line version of the self-calibrating digital instrument for flux measurements on superconductive magnets for particle accelerators, prototyped at the European Organization for Nuclear Research (CERN) in cooperation with the University of Sannio, is proposed. The instrument acquires voltage arising from rotating coils transducers. Then, the samples are online integrated and suitably processed in order to achieve flux analysis time down to 2.0 ìs, with resolution of 50 ns. Details about hardware and firmware conception, on-line measurement principle, and preliminary results of metrological characterization of the prototype are provided.

  12. On-line multidimensional separation systems for peptide analysis

    NARCIS (Netherlands)

    Stroink, T.

    2005-01-01

    Today, there is an increasing interest in selective and sensitive analysis of proteins and peptides with a relatively high speed. The first chapter of this thesis describes several strategies for the on-line multidimensional analysis of peptides and proteins in biological samples. This overview of t

  13. 活化法测量中子活化在线分析系统样品处的中子能谱%Neutron Spectrum Measurement with Activation Method in Sample Place of On-line Neutron Activation Analysis System

    Institute of Scientific and Technical Information of China (English)

    王松林; 孔祥忠; 邓勇军; 拓飞; 王琦; 位金锋; 李永明

    2009-01-01

    用多箔活化法测定了由Am-Be中子源慢化屏蔽系统构成的中子活化在线分析系统样品处的中子能谱.根据待测场点的中子注量率水平,选用了5种非裂变核材料箔,其中4种是中能区和热区的,1种是快区的,给出了各箔片的特性参数.通过在待测场点对箔片进行辐照,并测量其生成放射性核的γ放射性,计算出了各箔片的活化率.运用SAND-II和MSIT迭代方法,解出了待测场点的中子能谱.详细分析了数据处理过程中群截面的加工处理以及由于自屏蔽效应引起的群截面修正问题;研究了影响解谱精度的主要因素;对解谱结果作了一定的分析讨论;并用蒙特卡罗(MC)方法对最后的中子能谱做了不确定度分析.%The neutron spectrum in sample place of on-line neutron activation analysis system was measured with multiple foil activation technique. According to the neutron fluence level of measuring request, 5 kinds of non-fission nuclear material foils were selected, of which 4 were sensitive to thermal energy region and intermediate energy region, and 1 was sensitive to fast energy region. By measuring the foil activity, the neutron spectrum that was needed to measured was unfolded with the iterative methods SAND-II and MSIT. Meanwhile, the process of producing and modifying group cross section were analysed amply. The main factors which have influence on the accuracy of the solution were studied. The discussion for solution was done simply, and the uncertainty of solution was analysed by using the Monte Carlo method.

  14. On line routing per mobile phone

    DEFF Research Database (Denmark)

    Bieding, Thomas; Görtz, Simon; Klose, Andreas

    2009-01-01

    On-line routing is concerned with building vehicle routes in an ongoing fashion in such a way that customer requests arriving dynamically in time are efficiently and effectively served. An indispensable prerequisite for applying on-line routing methods is mobile communication technology. Addition...

  15. On-line high speed lipid extraction for nanoflow liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lee, Ju Yong; Yang, Joon Seon; Park, Se Mi; Byeon, Seul Kee; Moon, Myeong Hee

    2016-09-16

    An on-line lipid extraction method is introduced by utilizing a short capillary extraction column using HILIC and C4 particles prior to nanoflow liquid chromatography-tandem mass spectrometry (nLC-MS/MS). The on-line extraction using a urine sample spiked with PL standards showed similar or slightly higher recovery values (86%-96%) of phospholipids (PLs) compared to those obtained by the conventional off-line extraction based on the Folch method with or without using the air-exposed drying process. In this study, we demonstrated that PL oxidation can occur during the air-exposed drying process of lipid extracts in standard liquid-liquid extraction procedures, which was confirmed by the oxidized PL (OxPL) molecules that were generated from an off-line extraction using a few PL standards. Quantitative comparison of these OxPL species between on- and off-line extraction followed by nLC-MS/MS with multiple reaction monitoring (MRM) analysis showed a significant decrease (2-10 fold) in unwanted OxPL species when on-line extraction was employed. While the number of identified PLs from a urine sample was somewhat lower than those by off-line extraction, the number of OxPLs was significantly reduced (from 70 to 22) with on-line extraction. The new method offers high speed (∼5min) automated extraction of PLs with nLC-MS/MS analysis and presents the possibility of handling a biological sample with a very limited amount of lipids.

  16. Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts

    DEFF Research Database (Denmark)

    Brond, J. C.; Arvidsson, D.

    2016-01-01

    the amount of activity counts generated was less, indicating that raw data stored in the GT3X+ monitor is processed. Between 600 and 1,600 more counts per minute were generated with the sampling frequencies 40 and 100 Hz compared with 30 Hz during running. Sampling frequency affects the processing of Acti...

  17. Evaluation of standard methods for collecting and processing fuel moisture samples

    Science.gov (United States)

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  18. Real-time recursive hyperspectral sample and band processing algorithm architecture and implementation

    CERN Document Server

    Chang, Chein-I

    2017-01-01

    This book explores recursive architectures in designing progressive hyperspectral imaging algorithms. In particular, it makes progressive imaging algorithms recursive by introducing the concept of Kalman filtering in algorithm design so that hyperspectral imagery can be processed not only progressively sample by sample or band by band but also recursively via recursive equations. This book can be considered a companion book of author’s books, Real-Time Progressive Hyperspectral Image Processing, published by Springer in 2016. Explores recursive structures in algorithm architecture Implements algorithmic recursive architecture in conjunction with progressive sample and band processing Derives Recursive Hyperspectral Sample Processing (RHSP) techniques according to Band-Interleaved Sample/Pixel (BIS/BIP) acquisition format Develops Recursive Hyperspectral Band Processing (RHBP) techniques according to Band SeQuential (BSQ) acquisition format for hyperspectral data.

  19. Poss On-line (Personalisation of Self-Service Solutions across On-line platforms)

    DEFF Research Database (Denmark)

    Nielsen, Janni; Nielsen, Lene; Jespersen, Mikkel

    2005-01-01

    The project on Personalisation of Self-service Solutions across On-line Platforms (POSS ON-LINE) focuses on users, clients, and self-service solutions. It is based on the understanding that clients and users are different and have different goals, and that self-service takes place in different co...... at the process of development. However, we lack methods to predict user behaviour without having to deal with huge amounts of data and data from both quantitative data as well as life world observations are required....... the client and the user. The system gathers data about the user, which enables the client to push information to the user. Personalisation enables graphic user interface design that is personalised and relevant to the individual user and invites the user to get access to information with less strain....... Personalisation of self-service solutions is promising and IT companies are experiencing an increase in the clients' demands. At the same time the development of solutions moves within a shorter and shorter time span. Hence the process of innovations is paced and there is an increasing need of new ways of looking...

  20. Sample processing considerations for detecting copy number changes in formalin-fixed, paraffin-embedded tissues.

    Science.gov (United States)

    Jacobs, Sharoni

    2012-11-01

    The Whole Genome Sampling Analysis (WGSA) assay in combination with Affymetrix GeneChip Mapping Arrays is used for copy number analysis of high-quality DNA samples (i.e., samples that have been collected from blood, fresh or frozen tissue, or cell lines). Formalin-fixed, paraffin-embedded (FFPE) samples, however, represent the most prevalent form of archived clinical samples, but they provide additional challenges for molecular assays. FFPE processing usually results in the degradation of FFPE DNA and in the contamination and chemical modification of these DNA samples. Because of these issues, FFPE DNA is not suitable for all molecular assays designed for high-quality DNA samples. Strategies recommended for processing FFPE DNA samples through WGSA and to the Mapping arrays are described here.

  1. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay.

    Directory of Open Access Journals (Sweden)

    Cathrine Carlsen Bach

    Full Text Available In studies of perfluoroalkyl acids, the validity and comparability of measured concentrations may be affected by differences in the handling of biospecimens. We aimed to investigate whether measured plasma levels of perfluoroalkyl acids differed between blood samples subjected to delay and transportation prior to processing and samples with immediate processing and freezing.Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88 provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort. We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification.For samples taken in the winter, relative differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27 for perfluorooctane sulfonate. For perfluorooctanoate there was no difference between the two setups [corresponding estimate 1% (0, 3]. Differences were negligible in the summer for all compounds.Transport of blood samples and processing delay, similar to conditions applied in some large, population-based studies, may affect measured perfluoroalkyl acid concentrations, mainly when outdoor temperatures are low. Attention to processing conditions is needed in studies of perfluoroalkyl acid exposure in humans.

  2. 7 CFR 52.38c - Statistical sampling procedures for lot inspection of processed fruits and vegetables by attributes.

    Science.gov (United States)

    2010-01-01

    ... FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1..., truck, railroad car, or other similar conveyance. (b) Sample size. Samples shall be randomly selected...

  3. Detection of Porphyromonas gingivalis from Saliva by PCR by Using a Simple Sample-Processing Method

    OpenAIRE

    Mättö, Jaana; Saarela, Maria; Alaluusua, Satu; Oja, Virva; Jousimies-Somer, Hannele; Asikainen, Sirkka

    1998-01-01

    Simple sample-processing methods for PCR detection of Porphyromonas gingivalis, a major pathogen causing adult periodontitis, from saliva were studied. The ability to detect P. gingivalis from 118 salivary samples by PCR after boiling and Chelex 100 processing was compared with bacterial culture. P. gingivalis was detected three times more often by PCR than by culture. Chelex 100 processing of saliva proved to be effective in preventing PCR inhibition and was applied to determine the occurren...

  4. Conditional Sampling for Max-Stable Processes with a Mixed Moving Maxima Representation

    CERN Document Server

    Oesting, Marco

    2012-01-01

    This paper deals with the question of conditional sampling and prediction for the class of stationary max-stable processes which allow for a mixed moving maxima representation. We develop an exact procedure for conditional sampling using the Poisson point process structure of such processes. For explicit calculations we restrict ourselves to the one-dimensional case and use a finite number of shape functions satisfying some regularity conditions. For more general shape functions approximation techniques are presented. Our algorithm is applied to the Gaussian extreme value process and the Brown- Resnick process. Finally, we compare our computational results to other approaches.

  5. The User-friendly On-Line Diffusion Chamber

    CERN Document Server

    Aviles Acosta, Jaime

    2015-01-01

    The On-Line Diffusion Chamber is a stand-alone apparatus built to carry out short-live radiotracer diffusion studies. The availability of the on-demand production of isotopes in the ISOLDE facility, and the design of the apparatus to streamline the implantation process, annealing treatment, ion gun ablation with a tape transport system, and radiation intensity measurement with a Ge gamma detector all in the same apparatus, gives the On-Line Diffusion Chamber a unique ability to studies with short-lived radioisotopes or isomer states that are not possible in any other facility in the world.

  6. On-line Payment System Survey – eCash

    Directory of Open Access Journals (Sweden)

    Marius Popa

    2009-12-01

    Full Text Available The paper presents the main aspects regarding an on-line payment system. Some characteristics of such system are presented and an existing system is analyzed. On its fundamental sense, the electronic commerce is a concept that represents the purchase and sale process or exchange of products, services, information, using o computer network, inclusively the Internet. In the most part of the cases, the electronic commerce imply on-line payments that lead to creation of some kinds of electronic money and some specific payment systems. There are described the some electronic payment mechanisms and the architecture and the functions of the on-line payment system E-Cash are depicted.

  7. Strengthening weak ties through on-line gaming

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana Virginia; Kirchner, Kathrin

    On-line gaming became widespread in the last couple of years. The aim of the research presented in the paper is to figure out to what extent does game playing helps to strengthen weak ties and what additional factors influence this process. The approach is rather exploratory – some factors...... are grounded in theory, some are new. These factors are age, gender, place of origin, number of their Facebook connections (friends in Facebook terminology), the amount of time they are on Facebook, the amount of time they keep the Facebook site open, the amount of time they play on-line games, and the reasons...... for starting to play on-line games. Regarding the latter, we chose to focus only on escapist reasons....

  8. On-Line Impact Load Identification

    Directory of Open Access Journals (Sweden)

    Krzysztof Sekuła

    2013-01-01

    Full Text Available The so-called Adaptive Impact Absorption (AIA is a research area of safety engineering devoted to problems of shock absorption in various unpredictable scenarios of collisions. It makes use of smart technologies (systems equipped with sensors, controllable dissipaters and specialised tools for signal processing. Examples of engineering applications for AIA systems are protective road barriers, automotive bumpers or adaptive landing gears. One of the most challenging problems for AIA systems is on-line identification of impact loads, which is crucial for introducing the optimum real-time strategy of adaptive impact absorption. This paper presents the concept of an impactometer and develops the methodology able to perform real-time impact load identification. Considered dynamic excitation is generated by a mass M1 impacting with initial velocity V0. An analytical formulation of the problem, supported with numerical simulations and experimental verifications is presented. Two identification algorithms based on measured response of the impacted structure are proposed and discussed. Finally, a concept of the AIA device utilizing the idea of impactometer is briefly presented.

  9. On-line generalized Steiner problem

    Energy Technology Data Exchange (ETDEWEB)

    Awerbuch, B.; Azar, Y.; Bartal, Y. [Tel Aviv Univ. (Israel)

    1996-12-31

    The Generalized Steiner Problem (GSP) is defined as follows. We are given a graph with non-negative weights and a set of pairs of vertices. The algorithm has to construct minimum weight subgraph such that the two nodes of each pair are connected by a path. We consider the on-line generalized Steiner problem, in which pairs of vertices arrive on-line and are needed to be connected immediately. We give a simple O(log{sup 2} n) competitive deterministic on-line algorithm. The previous best online algorithm (by Westbrook and Yan) was O({radical}n log n) competitive. We also consider the network connectivity leasing problem which is a generalization of the GSP. Here edges of the graph can be either bought or leased for different costs. We provide simple randomized O(log{sup 2} n) competitive algorithm based on the on-line generalized Steiner problem result.

  10. The war against on-line piracy

    OpenAIRE

    Harris, Julian

    2011-01-01

    A summary by Julian Harris, Deputy General Editor Amicus Curiae, of US attempts to control what it identifies as rogue Internet sites engaged in on-line piracy and opposition to such legislative moves.

  11. Studies on the Analysis of Lead and Silica in Lead Processing Samples

    Directory of Open Access Journals (Sweden)

    R. Ravichandra Babu

    2014-01-01

    Full Text Available In Practice two samples have to be proceeded separately to determine both lead and silica in lead process samples like concentrates, coarse sinter etc. In the present recommended procedure, the lead and silica are precipitated together by using acid fuming, but, instead of using ammonium acetate treatment to separate lead and silica, a mixture of hydrochloric acid-sodium chloride is used to achieve the same purpose. This helps in determine all the components of lead process samples from the same solution without loss of accuracy in any of the components. This method saves considerable time and especially useful for routine analysis in process control lab.

  12. ACSEPP On-Line Electronic Payment Protocol

    Institute of Scientific and Technical Information of China (English)

    WANG Shao-bin; ZHU Xian; HONG Fan

    2004-01-01

    With analyzing the existing on-line electronic payment protocols, this paper presents a new on-line electronic payment protocol named ACSEPP: Anonymous, Convenient and Secure Electronic Payment Protocol.Its aim is to design a practical electronic payment protocol which is both secure and convenient.Without using PKI_CA frame, it realized the anonymity of consumer and merchant, the convenient of handling, the low cost of maintenance and the security.

  13. Pre-PCR processing: strategies to generate PCR-compatible samples.

    Science.gov (United States)

    Rådström, Peter; Knutsson, Rickard; Wolffs, Petra; Lövenklev, Maria; Löfström, Charlotta

    2004-02-01

    Polymerase chain reaction (PCR) is recognized as a rapid, sensitive, and specific molecular diagnostic tool for the analysis of nucleic acids. However, the sensitivity and kinetics of diagnostic PCR may be dramatically reduced when applied directly to biological samples, such as blood and feces, owing to PCR-inhibitory components. As a result, pre-PCR processing procedures have been developed to remove or reduce the effects of PCR inhibitors. Pre-PCR processing comprises all steps prior to the detection of PCR products, that is, sampling, sample preparation, and deoxyribonucleic acid (DNA) amplification. The aim of pre-PCR processing is to convert a complex biological sample with its target nucleic acids/cells into PCR-amplifiable samples by combining sample preparation and amplification conditions. Several different pre-PCR processing strategies are used: (1) optimization of the DNA amplification conditions by the use of alternative DNA polymerases and/or amplification facilitators, (2) optimization of the sample preparation method, (3) optimization of the sampling method, and (4) combinations of the different strategies. This review describes different pre-PCR processing strategies to circumvent PCR inhibition to allow accurate and precise DNA amplification.

  14. Understanding scaling through history-dependent processes with collapsing sample space

    Science.gov (United States)

    Corominas-Murtra, Bernat; Hanel, Rudolf; Thurner, Stefan

    2015-01-01

    History-dependent processes are ubiquitous in natural and social systems. Many such stochastic processes, especially those that are associated with complex systems, become more constrained as they unfold, meaning that their sample space, or their set of possible outcomes, reduces as they age. We demonstrate that these sample-space-reducing (SSR) processes necessarily lead to Zipf’s law in the rank distributions of their outcomes. We show that by adding noise to SSR processes the corresponding rank distributions remain exact power laws, p(x)∼x−λ, where the exponent directly corresponds to the mixing ratio of the SSR process and noise. This allows us to give a precise meaning to the scaling exponent in terms of the degree to which a given process reduces its sample space as it unfolds. Noisy SSR processes further allow us to explain a wide range of scaling exponents in frequency distributions ranging from α=2 to ∞. We discuss several applications showing how SSR processes can be used to understand Zipf’s law in word frequencies, and how they are related to diffusion processes in directed networks, or aging processes such as in fragmentation processes. SSR processes provide a new alternative to understand the origin of scaling in complex systems without the recourse to multiplicative, preferential, or self-organized critical processes. PMID:25870294

  15. Sistema de Optimización en Línea y Diagnosis de Fallos para Procesos Químicos An On-line Optimization and Fault Diagnosis System for Chemical Processes

    Directory of Open Access Journals (Sweden)

    Ignacio Yélamos

    2007-01-01

    Full Text Available En este artículo, la técnica Evolución en Tiempo Real (ETR es aplicada a la optimización en línea de una columna de destilación multicomponente. Un Sistema de Diagnóstico de Fallos (SDF dentro de un módulo de supervisión es responsable de la gestión de cualquier incidencia (fallos o perturbaciones que ocurra en la planta, consiguiéndose un funcionamiento en línea más robusto. La implementación de este módulo supervisado (ETRS se ha llevado a cabo usando Matlab® y el simulador comercial Hysys®, aprovechando las posibilidades de comunicación existentes entre ambos. Se tratan diferentes incidencias, involucrando diferentes fuentes y tipos de perturbaciones. Los resultados de la ETRS son comparados con los que se obtuvieron mediante la Optimización en Tiempo Real clásica.In this paper, the Real Time Evolution technique (RTE is applied to the on-line optimization of a multi-component distillation column. A Fault Diagnosis System (FDS implemented within a supervisory module is responsible for handling incidences (faults or disturbances occurring in the plant, achieving more robust on-line performance. The implementation of the supervised scheme (SRTE has been performed using Matlab® and the commercial simulation software Hysys®, taking advantage of their communication capabilities. Different possible plant incidences are considered involving different sources and types of disturbances. Results of SRTE are compared with those obtained using the standard Real Time Optimization approach.

  16. Stationary and related stochastic processes sample function properties and their applications

    CERN Document Server

    Cramér, Harald

    2004-01-01

    This graduate-level text offers a comprehensive account of the general theory of stationary processes, with special emphasis on the properties of sample functions. Assuming a familiarity with the basic features of modern probability theory, the text develops the foundations of the general theory of stochastic processes, examines processes with a continuous-time parameter, and applies the general theory to procedures key to the study of stationary processes. Additional topics include analytic properties of the sample functions and the problem of time distribution of the intersections between a

  17. Fast Sampling for Strongly Rayleigh Measures with Application to Determinantal Point Processes

    OpenAIRE

    Li, Chengtao; Jegelka, Stefanie; Sra, Suvrit

    2016-01-01

    In this note we consider sampling from (non-homogeneous) strongly Rayleigh probability measures. As an important corollary, we obtain a fast mixing Markov Chain sampler for Determinantal Point Processes.

  18. Gender Differences in Identity Processing Style and Islamic Religiosity in an Iranian Undergraduate University Sample

    National Research Council Canada - National Science Library

    S Khodarahimi; D L Cothran

    2009-01-01

      The goals of the present study were twofold: to examine gender differences in identity processing styles and religiosity and to examine relationships between the two in an Iranian undergraduate university sample...

  19. Improvements to sample processing and measurement to enable more widespread environmental application of tritium

    Energy Technology Data Exchange (ETDEWEB)

    Moran, James; Alexander, Thomas; Aalseth, Craig; Back, Henning; Mace, Emily; Overman, Cory; Seifert, Allen; Freeburg, Wilcox

    2017-08-01

    Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120 mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of T behavior in the environment.

  20. Probabilistic Round Trip Contamination Analysis of a Mars Sample Acquisition and Handling Process Using Markovian Decompositions

    Science.gov (United States)

    Hudson, Nicolas; Lin, Ying; Barengoltz, Jack

    2010-01-01

    A method for evaluating the probability of a Viable Earth Microorganism (VEM) contaminating a sample during the sample acquisition and handling (SAH) process of a potential future Mars Sample Return mission is developed. A scenario where multiple core samples would be acquired using a rotary percussive coring tool, deployed from an arm on a MER class rover is analyzed. The analysis is conducted in a structured way by decomposing sample acquisition and handling process into a series of discrete time steps, and breaking the physical system into a set of relevant components. At each discrete time step, two key functions are defined: The probability of a VEM being released from each component, and the transport matrix, which represents the probability of VEM transport from one component to another. By defining the expected the number of VEMs on each component at the start of the sampling process, these decompositions allow the expected number of VEMs on each component at each sampling step to be represented as a Markov chain. This formalism provides a rigorous mathematical framework in which to analyze the probability of a VEM entering the sample chain, as well as making the analysis tractable by breaking the process down into small analyzable steps.

  1. A method for disaggregating clay concretions and eliminating formalin smell in the processing of sediment samples

    DEFF Research Database (Denmark)

    Cedhagen, Tomas

    1989-01-01

    A complete handling procedure for processing sediment samples is described. It includes some improvements of conventional methods. The fixed sediment sample is mixed with a solution of the alkaline detergent AJAX® (Colgate-Palmolive). It is kept at 80-900 C for 20-40 min. This treatment facilitates...

  2. Probabilistic Round Trip Contamination Analysis of a Mars Sample Acquisition and Handling Process Using Markovian Decompositions

    Science.gov (United States)

    Hudson, Nicolas; Lin, Ying; Barengoltz, Jack

    2010-01-01

    A method for evaluating the probability of a Viable Earth Microorganism (VEM) contaminating a sample during the sample acquisition and handling (SAH) process of a potential future Mars Sample Return mission is developed. A scenario where multiple core samples would be acquired using a rotary percussive coring tool, deployed from an arm on a MER class rover is analyzed. The analysis is conducted in a structured way by decomposing sample acquisition and handling process into a series of discrete time steps, and breaking the physical system into a set of relevant components. At each discrete time step, two key functions are defined: The probability of a VEM being released from each component, and the transport matrix, which represents the probability of VEM transport from one component to another. By defining the expected the number of VEMs on each component at the start of the sampling process, these decompositions allow the expected number of VEMs on each component at each sampling step to be represented as a Markov chain. This formalism provides a rigorous mathematical framework in which to analyze the probability of a VEM entering the sample chain, as well as making the analysis tractable by breaking the process down into small analyzable steps.

  3. On-line digestion system for protein characterization and proteome analysis.

    Science.gov (United States)

    López-Ferrer, Daniel; Petritis, Konstantinos; Lourette, Natacha M; Clowers, Brian; Hixson, Kim K; Heibeck, Tyler; Prior, David C; Pasa-Tolić, Ljiljana; Camp, David G; Belov, Mikhail E; Smith, Richard D

    2008-12-01

    An efficient on-line digestion system that reduces the number of sample manipulation steps has been demonstrated for high-throughput proteomics. By incorporating a pressurized sample loop into a liquid chromatography-based separation system, both sample and enzyme (e.g., trypsin) can be simultaneously introduced to produce a complete, yet rapid digestion. Both standard proteins and a complex Shewanella oneidensis global protein extract were digested and analyzed using the automated online pressurized digestion system coupled to an ion mobility time-of-flight mass spectrometer, an ion trap mass spectrometer, or both. The system denatured, digested, and separated product peptides in a manner of minutes, making it amenable to on-line high-throughput applications. In addition to simplifying and expediting sample processing, the system was easy to implement and no cross-contamination was observed among samples. As a result, the online digestion system offers a powerful approach for high-throughput screening of proteins that could prove valuable in biochemical research (rapid screening of protein-based drugs).

  4. Efficiently Building On-line Tools for Distributed Heterogeneous Environments

    Directory of Open Access Journals (Sweden)

    Günther Rackl

    2002-01-01

    Full Text Available Software development is getting more and more complex, especially within distributed middleware-based environments. A major drawback during the overall software development process is the lack of on-line tools, i.e. tools applied as soon as there is a running prototype of an application. The MIMO MIddleware MOnitor provides a solution to this problem by implementing a framework for an efficient development of on-line tools. This paper presents a methodology for developing on-line tools with MIMO. As an example scenario, we choose a distributed medical image reconstruction application, which represents a test case with high performance requirements. Our distributed, CORBA-based application is instrumented for being observed with MIMO and related tools. Additionally, load balancing mechanisms are integrated for further performance improvements. As a result, we obtain an integrated tool environment for observing and steering the image reconstruction application. By using our rapid tool development process, the integration of on-line tools shows to be very convenient and enables an efficient tool deployment.

  5. Data processing of small samples based on grey distance information approach

    Institute of Scientific and Technical Information of China (English)

    Ke Hongfa; Chen Yongguang; Liu Yi

    2007-01-01

    Data processing of small samples is an important and valuable research problem in the electronic equipment test.Because it is difficult and complex to determine the probability distribution of small samples, it is difficult to use the traditional probability theory to process the samples and assess the degree of uncertainty.Using the grey relational theory and the norm theory, the grey distance information approach, which is based on the grey distance information quantity of a sample and the average grey distance information quantity of the samples, is proposed in this article.The definitions of the grey distance information quantity of a sample and the average grey distance information quantity of the samples, with their characteristics and algorithms, are introduced.The correlative problems, including the algorithm of estimated value, the standard deviation, and the acceptance and rejection criteria of the samples and estimated results, are also proposed.Moreover, the information whitening ratio is introduced to select the weight algorithm and to compare the different samples.Several examples are given to demonstrate the application of the proposed approach.The examples show that the proposed approach, which has no demand for the probability distribution of small samples, is feasible and effective.

  6. Formación on line

    Directory of Open Access Journals (Sweden)

    O. Grau-Perejoan

    Full Text Available La formación on line es una modalidad de enseñanza a distancia basada en las nuevas tecnologías. En este artículo se pretende hacer una introducción a base de describir a grandes rasgos sus características principales: asincronía, no presencialidad, comunicación escrita, función del profesor on line, así como los retos, los riesgos, las ventajas y los inconvenientes que plantea. Se exponen las diferencias entre la formación on line y la formación presencial, de manera que los docentes puedan adaptar de la mejor manera posible sus propuestas formativas a la modalidad on line. Se introduce el importantísimo papel de la planificación y de la fase de diseño y, finalmente, se repasan conceptos útiles para comprender mejor el mundo de la formación on line como son los conceptos entorno virtual de aprendizaje (EVA o Blended Learning (B-Learning.

  7. Unexpected toxicity to aquatic organisms of some aqueous bisphenol A samples treated by advanced oxidation processes.

    Science.gov (United States)

    Tišler, Tatjana; Erjavec, Boštjan; Kaplan, Renata; Şenilă, Marin; Pintar, Albin

    2015-01-01

    In this study, photocatalytic and catalytic wet-air oxidation (CWAO) processes were used to examine removal efficiency of bisphenol A from aqueous samples over several titanate nanotube-based catalysts. Unexpected toxicity of bisphenol A (BPA) samples treated by means of the CWAO process to some tested species was determined. In addition, the CWAO effluent was recycled five- or 10-fold in order to increase the number of interactions between the liquid phase and catalyst. Consequently, the inductively coupled plasma mass spectrometry (ICP-MS) analysis indicated higher concentrations of some toxic metals like chromium, nickel, molybdenum, silver, and zinc in the recycled samples in comparison to both the single-pass sample and the photocatalytically treated solution. The highest toxicity of five- and 10-fold recycled solutions in the CWAO process was observed in water fleas, which could be correlated to high concentrations of chromium, nickel, and silver detected in tested samples. The obtained results clearly demonstrated that aqueous samples treated by means of advanced oxidation processes should always be analyzed using (i) chemical analyses to assess removal of BPA and total organic carbon from treated aqueous samples, as well as (ii) a battery of aquatic organisms from different taxonomic groups to determine possible toxicity.

  8. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2008-01-01

    Full Text Available The on-line user of today has access to a vast collection of information resources. In addition, the developments in Internet and Web technologies have made it even easier for surfers to anonymously get access to on-line pornography. The purpose of this research was to investigate the extent to which access to on-line pornography at the University of Johannesburg can be managed. For the empirical part of this research 1037 questionnaires were proportionally distributed to and completed by students on all five campuses of the university. The questionnaire consisted of four sections: biographical information; university computer facility usage; university acceptable use policy; and personal experience with university computer facilities. The gender distribution for the sample was almost even, with a total of 49,4% male participants and 50,6% female, with the largest grouping of respondents (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  9. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2007-12-01

    Full Text Available The on-line user of today has access to a vast collection of information resources. In addition, the developments in Internet and Web technologies have made it even easier for surfers to anonymously get access to on-line pornography. The purpose of this research was to investigate the extent to which access to on-line pornography at the University of Johannesburg can be managed. For the empirical part of this research 1037 questionnaires were proportionally distributed to and completed by students on all five campuses of the university. The questionnaire consisted of four sections: biographical information; university computer facility usage; university acceptable use policy; and personal experience with university computer facilities. The gender distribution for the sample was almost even, with total of 49,4% male participants and 50,6% female, with the largest grouping of respondents(61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  10. Characterization of a condensed-phase membrane introduction mass spectrometry (CP-MIMS) interface using a methanol acceptor phase coupled with electrospray ionization for the continuous on-line quantitation of polar, low-volatility analytes at trace levels in complex aqueous samples.

    Science.gov (United States)

    Duncan, K D; McCauley, E P B; Krogh, E T; Gill, C G

    2011-05-15

    We report the development and application of a capillary hollow fibre membrane interface using methanol as an acceptor phase to deliver target analytes to an electrospray ionization source and a triple quadrupole mass spectrometer. Superior fluid handling systems lead to greater signal stability and membrane integrity for the continuous on-line monitoring of polar and charged analytes in complex aqueous samples with detection limits in the parts-per-trillion to parts-per-billion range. The system can be operated in either a continuous flow or a stopped acceptor flow mode - the latter giving rise to greater sensitivity. We report detection limits, enrichment factors and signal response times for selected analytes with polydimethylsiloxane and Nafion® polymer membrane interfaces. In addition, we demonstrate the use of this interface to detect pharmaceuticals and other contaminants in natural water and artificial urine. The improved sensitivity and analytical response times of our CP-MIMS system make it possible to continuously monitor dynamic chemical systems with temporal resolutions on the order of minutes. Presented is a comparison of the performance of CP-MIMS versus direct infusion electrospray ionization, demonstrating the potential advantages over direct infusion for trace analyte measurements in complex, high ionic strength samples. Furthermore, by continuously flowing a reaction mixture in a closed loop over the interface, we demonstrate the use of the system as an in situ reaction-monitoring platform for the chlorination of a model organic compound in aqueous solution. Copyright © 2011 John Wiley & Sons, Ltd.

  11. FLOW INJECTION ON-LINE SEPARATION AND SPECTROPHOTOMETRIC DETERMINATION OF TRACES OF LEAD IN ENVIRONMENTAL SAMPLES%环境样品中痕量铅的流动注射在线分离及分光光度检测

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A flow injection method has been developed for the determination of lead in environmental samples by use of on-line preconcentration on a Pb*SpecTM column and spectrophotometric detection. The lead in sample solutions was adsorbed selectively on the column from 1mol*l-1 nitric acid and the retained lead was eluted with 0.1mol*l-1 ammonium oxalate.4-(2-pyridylazo)resorcinol (PAR) was used as a chromogenic reagent at pH 10 and the absorbance of Pb-PAR complex was monitored at 530 nm. The pumps, valves and spectrophotometer were controlled by a personal computer. The detection limit (3σ) was 3ng of lead. The RSD is 1.7% at a level of 0.4μg lead. The proposed method was successfully applied to the determination of lead in fly ash of an incinerator for industrial waste and in river water certified reference material provided by the Japan Society for Analytical Chemistry.

  12. On-line phase space measurement with kicker excitation

    Science.gov (United States)

    Dietrich, J.; Maier, R.; Mohos, I.

    1998-12-01

    A new method for on-line phase space measurements with kicker excitation at COSY was developed. The position data were measured using the analog output of two beam position monitors (BPMs) and directly monitored on a digital storage oscilloscope with an external clock (bunch-synchronous sampling). Nonlinear behavior of the proton beam was visible as well as were resonance islands. Typical measurements are presented.

  13. Capillary absorption spectrometer and process for isotopic analysis of small samples

    Science.gov (United States)

    Alexander, M. Lizabeth; Kelly, James F.; Sams, Robert L.; Moran, James J.; Newburn, Matthew K.; Blake, Thomas A.

    2016-03-29

    A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The method also permits sampling in vivo permitting real-time ambient studies of microbial communities.

  14. Effect of histologic processing on dimensions of skin samples obtained from cat cadavers.

    Science.gov (United States)

    Jeyakumar, Sakthila; Smith, Annette N; Schleis, Stephanie E; Cattley, Russell C; Tillson, D Michael; Henderson, Ralph A

    2015-11-01

    OBJECTIVE To determine changes in dimensions of feline skin samples as a result of histologic processing and to identify factors that contributed to changes in dimensions of skin samples after sample collection. SAMPLE Cadavers of 12 clinically normal cats. PROCEDURES Skin samples were obtained bilaterally from 3 locations (neck, thorax, and tibia) of each cadaver; half of the thoracic samples included underlying muscle. Length, width, and depth were measured at 5 time points (before excision, after excision, after application of ink to mark tissue margins, after fixation in neutral-buffered 10% formalin for 36 hours, and after completion of histologic processing and staining with H&E stain). Measurements obtained after sample collection were compared with measurements obtained before excision. RESULTS At the final time point, tissue samples had decreased in length (mean decrease, 32.40%) and width (mean decrease, 34.21%) and increased in depth (mean increase, 54.95%). Tissue from the tibia had the most shrinkage in length and width and that from the neck had the least shrinkage. Inclusion of underlying muscle on thoracic skin samples did not affect the degree of change in dimensions. CONCLUSIONS AND CLINICAL RELEVANCE In this study, each step during processing from excision to formalin fixation and histologic processing induced changes in tissue dimensions, which were manifested principally as shrinkage in length and width and increase in depth. Most of the changes occured during histologic processing. Inclusion of muscle did not affect thoracic skin shrinkage. Shrinkage should be a consideration when interpreting surgical margins in clinical cases. 945).

  15. Study on Electro-Polishing Process by Niobium-Plate Sample With Artificial Pits

    Energy Technology Data Exchange (ETDEWEB)

    T. Saeki, H. Hayano, S. Kato, M. Nishiwaki, M. Sawabe, W.A. Clemens, R.L. Geng, R. Manus, P.V. Tyagi

    2011-07-01

    The Electro-polishing (EP) process is the best candidate of final surface-treatment for the production of ILC cavities. Nevertheless, the development of defects on the inner-surface of the Superconducting RF cavity during EP process has not been studied by experimental method. We made artificial pits on the surface of a Nb-plate sample and observed the development of the pit-shapes after each step of 30um-EP process where 120um was removed by EP in total. This article describes the results of this EP-test of Nb-sample with artificial pits.

  16. Multivariate CARMA processes, continuous-time state space models and complete regularity of the innovations of the sampled processes

    CERN Document Server

    Schlemm, Eckhard; 10.3150/10-BEJ329

    2012-01-01

    The class of multivariate L\\'{e}vy-driven autoregressive moving average (MCARMA) processes, the continuous-time analogs of the classical vector ARMA processes, is shown to be equivalent to the class of continuous-time state space models. The linear innovations of the weak ARMA process arising from sampling an MCARMA process at an equidistant grid are proved to be exponentially completely regular ($\\beta$-mixing) under a mild continuity assumption on the driving L\\'{e}vy process. It is verified that this continuity assumption is satisfied in most practically relevant situations, including the case where the driving L\\'{e}vy process has a non-singular Gaussian component, is compound Poisson with an absolutely continuous jump size distribution or has an infinite L\\'{e}vy measure admitting a density around zero.

  17. 多喷嘴水煤浆气化重要设备的在线清洗%On-line Cleaning of Key Equipment of Multiple Nozzle CWS Gasification Process Plant

    Institute of Scientific and Technical Information of China (English)

    孔德升; 孙化祥; 冯国印

    2016-01-01

    分析了多喷嘴水煤浆气化装置在运行中遇到的二级滚筒筛堵塞、废水换热器堵塞和酸性气冷凝器腐蚀内漏的原因,采取了一系列改造措施,实现了锁斗冲洗水换热器、废水换热器和酸性气冷凝器在线冲洗(吹扫)、二级滚筒筛在线清理,在运行中取得了较为理想的效果。%This article analyzed the reasons of the two-stage drum screen blocking, waste water heat exchanger blocking and internal leakage of acid gas condenser, a series of reforming measures were taken to realize on-line cleaning (purging) of lock hopper flushing water heat exchanger, waste water heat exchanger, acidic gas condenser and two-stage drum screen, which obtained good effects during operation .

  18. Educational On-Line Gaming Propensity

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana; Kirchner, Kathrin

    2014-01-01

    Educational on-line games are promising for new generations of students who are grown up digital. Th e new generations of students are technology savvy and spend lots of time on the web and on social networks. Based on an exploratory study, this article investigates the factors that infl uence...... students’ willingness to participate in serious games for teaching/learning. Th is study investigates the relationship between students’ behavior on Facebook, Facebook games, and their attitude toward educational on-line games. Th e results of the study reveal that the early adopters of educational games...

  19. On-line determination of oxygen isotope ratios of water or ice by mass spectrometry.

    Science.gov (United States)

    Leuenberger, M; Huber, C

    2002-09-15

    Oxygen isotope ratio determination on any of the water phases (water vapor, water, ice) is of great relevance in different research fields such as climate and paleoclimate studies, geological surveys, and hydrological studies. The conventional technique for oxygen isotope measurement involves equilibration with carbon dioxide gas for a given time with a subsequent isotope determination. The equilibration technique is available in different layouts, but all of them are rather time-consuming. Here we report a new on-line technique that processes water samples as well as ice samples. The same principal, CO2 hydration, is used but speeded up by (i) a direct injection and full dissolution of CO2 in the water, (ii) an increased isotope exchange temperature at 50 degrees C, and (iii) a rapid gas extraction by means of an air-permeable membrane into a continuous helium flux supplying the isotope ratio mass spectrometer with the sample gas. The precision is better than 0.1/1000 which is only slightly larger than with the conventional equilibration technique. This on-line technique allows analysis of 1 m of ice with a resolution of 1-3 cm, depending on the meltwater flux, within 1 h. Similarly, continuous and fast analysis can be performed for aqueous samples for hydrological, geological, and perhaps medical applications.

  20. Nonuniform sampling and non-Fourier signal processing methods in multidimensional NMR.

    Science.gov (United States)

    Mobli, Mehdi; Hoch, Jeffrey C

    2014-11-01

    Beginning with the introduction of Fourier Transform NMR by Ernst and Anderson in 1966, time domain measurement of the impulse response (the free induction decay, FID) consisted of sampling the signal at a series of discrete intervals. For compatibility with the discrete Fourier transform (DFT), the intervals are kept uniform, and the Nyquist theorem dictates the largest value of the interval sufficient to avoid aliasing. With the proposal by Jeener of parametric sampling along an indirect time dimension, extension to multidimensional experiments employed the same sampling techniques used in one dimension, similarly subject to the Nyquist condition and suitable for processing via the discrete Fourier transform. The challenges of obtaining high-resolution spectral estimates from short data records using the DFT were already well understood, however. Despite techniques such as linear prediction extrapolation, the achievable resolution in the indirect dimensions is limited by practical constraints on measuring time. The advent of non-Fourier methods of spectrum analysis capable of processing nonuniformly sampled data has led to an explosion in the development of novel sampling strategies that avoid the limits on resolution and measurement time imposed by uniform sampling. The first part of this review discusses the many approaches to data sampling in multidimensional NMR, the second part highlights commonly used methods for signal processing of such data, and the review concludes with a discussion of other approaches to speeding up data acquisition in NMR.

  1. Studies on the Electro-Polishing process with Nb sample plates at KEK

    Energy Technology Data Exchange (ETDEWEB)

    Saeki, Takayuki [KEK; Funahashi, Y. [KEK; Hayano, Hitoshi [KEK; Kato, Seigo [KEK; Nishiwaki, Michiru [KEK; Sawabe, Motoaki [KEK; Ueno, Kenji [KEK; Watanabe, K. [KEK; Clemens, William A. [JLAB; Geng, Rongli [JLAB; Manus, Robert L. [JLAB; Tyagi, Puneet [GUAS/AS, Ibaraki

    2009-11-01

    In this article, two subjects would be described. the first subject is on the production of stains on the surface of Nb sample plates in Electro-polishing (EP) process and the second subject is on the development of defects/pits in the EP process on the surface of a Nb sample plate. Recently, some 9-cell cavities were treated with new EP acid at KEK and the performance of these cavities were limited by heavy field emissions. On the inside surface of these cavities, brown stains were observed. We made an effort to reproduce the brown stains on Nb sample plates with an EP setup in laboratory with varying the concentration of Nibium in the EP acid. We found that the brown stains would appear only when processed with new EP acid. In the second subject, we made artificial pits on the surface of a Nb-sample plate and observed the development of the pits after each step of 30um-EP process where 120um was removed in total by the EP process. This article describes these series EP-tests with Nb sample plates at KEK.

  2. Sampling the food processing environment: taking up the cudgel for preventive quality management in food processing environments.

    Science.gov (United States)

    Wagner, Martin; Stessl, Beatrix

    2014-01-01

    The Listeria monitoring program for Austrian cheese factories was established in 1988. The basic idea is to control the introduction of L. monocytogenes into the food processing environment, preventing the pathogen from contaminating the food under processing. The Austrian Listeria monitoring program comprises four levels of investigation, dealing with routine monitoring of samples and consequences of finding a positive sample. Preventive quality control concepts attempt to detect a foodborne hazard along the food processing chain, prior to food delivery, retailing, and consumption. The implementation of a preventive food safety concept provokes a deepened insight by the manufacturers into problems concerning food safety. The development of preventive quality assurance strategies contributes to the national food safety status and protects public health.

  3. [Sampling plan, weighting process and design effects of the Brazilian Oral Health Survey].

    Science.gov (United States)

    Silva, Nilza Nunes da; Roncalli, Angelo Giuseppe

    2013-12-01

    To present aspects of the sampling plan of the Brazilian Oral Health Survey (SBBrasil Project). with theoretical and operational issues that should be taken into account in the primary data analyses. The studied population was composed of five demographic groups from urban areas of Brazil in 2010. Two and three stage cluster sampling was used. adopting different primary units. Sample weighting and design effects (deff) were used to evaluate sample consistency. In total. 37,519 individuals were reached. Although the majority of deff estimates were acceptable. some domains showed distortions. The majority (90%) of the samples showed results in concordance with the precision proposed in the sampling plan. The measures to prevent losses and the effects the cluster sampling process in the minimum sample sizes proved to be effective for the deff. which did not exceeded 2. even for results derived from weighting. The samples achieved in the SBBrasil 2010 survey were close to the main proposals for accuracy of the design. Some probabilities proved to be unequal among the primary units of the same domain. Users of this database should bear this in mind, introducing sample weighting in calculations of point estimates, standard errors, confidence intervals and design effects.

  4. 基于时间Dirichlet过程混合模型的在线目标跟踪%On-line Target Tracking Using Temporal Dirichlet Process Mixture Model

    Institute of Scientific and Technical Information of China (English)

    孙建中; 熊忠阳; 张玉芳

    2013-01-01

    针对目标跟踪过程中,可变目标表观的特征数据会发生“分布漂移”的问题,提出一种基于非参贝叶斯多模表观模型的目标跟踪方法.首先,以时间Dirichlet过程为先验分布,把先前估计的目标样本划分为不同的聚集,使得每个聚集表示一类表观,同时,每个表现类被建模为判别式分类器;然后,基于贝叶斯后验推断,权衡先前表观模型的分类误差和拆分聚集的代价,从数据中自主学习表现模型;最后,基于Noisy-OR模型,以贪心(Greedy)策略协同各表观分类器判别出目标.仿真结果表明该方法能较好的跟踪可变目标表观,改善了目标跟踪性能.%To cope with appearance variations of the target object during visual tracking,a nonparametric Bayesian multi-modal appearance model for learning over time was proposed.First,by taking the temporal Dirichlet process as prior distribution,the proposed model separated target samples previously estimated into several clusters.Each cluster represented a certain type of the target appearance,which was modeled as discriminative classifiers.Then,to balance the trade-off between the classification error of appearance model and the cost for splitting the clusters,the multi-modal appearance model was automatically learned by the use of Bayesian posterior inference.Finally,based on the Noisy-OR model,a greedy algorithm was used to discriminate the target object by combining the outputs of appearance classifiers.The simulation results show that the proposed method can track an object under rapid appearance changes and achieve better tracking results with high accuracy.

  5. Review of trigger and on-line processors at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Lankford, A.J.

    1984-07-01

    The role of trigger and on-line processors in reducing data rates to manageable proportions in e/sup +/e/sup -/ physics experiments is defined not by high physics or background rates, but by the large event sizes of the general-purpose detectors employed. The rate of e/sup +/e/sup -/ annihilation is low, and backgrounds are not high; yet the number of physics processes which can be studied is vast and varied. This paper begins by briefly describing the role of trigger processors in the e/sup +/e/sup -/ context. The usual flow of the trigger decision process is illustrated with selected examples of SLAC trigger processing. The features are mentioned of triggering at the SLC and the trigger processing plans of the two SLC detectors: The Mark II and the SLD. The most common on-line processors at SLAC, the BADC, the SLAC Scanner Processor, the SLAC FASTBUS Controller, and the VAX CAMAC Channel, are discussed. Uses of the 168/E, 3081/E, and FASTBUS VAX processors are mentioned. The manner in which these processors are interfaced and the function they serve on line is described. Finally, the accelerator control system for the SLC is outlined. This paper is a survey in nature, and hence, relies heavily upon references to previous publications for detailed description of work mentioned here. 27 references, 9 figures, 1 table.

  6. Occurrence of Arcobacter in Iranian poultry and slaughterhouse samples implicates contamination by processing equipment and procedures.

    Science.gov (United States)

    Khoshbakht, R; Tabatabaei, M; Shirzad Aski, H; Seifi, S

    2014-01-01

    1. The occurrence of Arcobacter spp. and three pathogenic species of Arcobacter from Iranian poultry carcasses was investigated at different steps of broiler processing to determine critical control points for reducing carcass contamination. 2. Samples were collected from (a) cloaca immediately before processing, (b) different points during processing and (c) at different stations in a processing plant of a slaughterhouse in southern Iran. 3. After enrichment steps in Arcobacter selective broth, DNA of the samples was extracted and three significant pathogen species of Arcobacter were identified based on polymerase chain reaction (PCR) detection of 16S rRNA and specific species PCR. 4. Out of a total of 540 samples, 244 (45%) were positive for Arcobacter spp. Arcobacter butzleri was more frequently detected (73% ± 13.9%) than A. cryaeophilus (9% ± 13.9%) and A. skirrowii (4.1%). In addition, co-colonisation (A. butzleri and A. cryaerophilus) occurred in 13.9% of the positive samples. 5. The results indicate a high prevalence of Arcobacter in the investigated slaughterhouse and broiler carcasses and that Arcobacter is not a normal flora of the broilers. Evidence for the presence of Arcobacter in the environment and water of processing plants suggests that these are sources of contamination of poultry carcasses. In addition, contamination of the poultry carcasses can spread between poultry meats in different parts and processes of the slaughterhouse (pre-scalding to after evisceration).

  7. Study of on-line analysis using energy dispersive X-ray fluorescence spectrometry for controlling lanthanum and neodymium extraction

    Energy Technology Data Exchange (ETDEWEB)

    Wenli, Li; Ascenzo, G.D`; Curini, R. [Department of Chemistry, University of Rome `La Sapienza`, Rome (Italy); Gasparini, G.M.; Casarci, M.; Mattia, B.; Traverso, D.M.; Bellisario, F. [ENEA, CRE Casaccia INN-NUMA (Italy)

    1998-05-04

    Many rare-earth extraction processes require frequent control over separation process quality. Ideally, an analysis method for this type should be simple, rapid and reliable. Energy dispersive X-ray fluorescence (EDXRF) spectrometry, due to its relative simplicity of instrumentation, speed of analysis, and non-destructive nature, is well suited to this on-line analysis application. In particular, since the radioisotope energy dispersive XRF method eliminates the need to transport samples to a laboratory which houses the X-ray spectrometry, it is most commonly used for on-line analysis of extraction systems. The present paper describes an attempt to type the radioisotope source {sup 241}Am XRF on-line analysis arrangement coupled with a personal computer for controlling a lanthanum and neodymium separation process. From the HpGe detector (high-purity germanium) response, a continuous spectral signal is observed during loading of the feed samples. The separation process using countercurrent extraction consists of a 16-stage laboratory mixer-settler, a switching valve, and a pumping system. The performance of this control system is illustrated by extracting La, Nd acidic solutions with 100% tributyl phosphate

  8. Microfluidic solutions enabling continuous processing and monitoring of biological samples: A review.

    Science.gov (United States)

    Karle, Marc; Vashist, Sandeep Kumar; Zengerle, Roland; von Stetten, Felix

    2016-07-27

    The last decade has witnessed tremendous advances in employing microfluidic solutions enabling Continuous Processing and Monitoring of Biological Samples (CPMBS), which is an essential requirement for the control of bio-processes. The microfluidic systems are superior to the traditional inline sensors due to their ability to implement complex analytical procedures, such as multi-step sample preparation, and enabling the online measurement of parameters. This manuscript provides a backgound review of microfluidic approaches employing laminar flow, hydrodynamic separation, acoustophoresis, electrophoresis, dielectrophoresis, magnetophoresis and segmented flow for the continuous processing and monitoring of biological samples. The principles, advantages and limitations of each microfluidic approach are described along with its potential applications. The challenges in the field and the future directions are also provided.

  9. Application Of Relevance Maps Method To Evaluate The Suitability Of Coal Samples For Fluidal Gasification Process

    Directory of Open Access Journals (Sweden)

    Jamroz Dariusz

    2016-01-01

    The methods being used to visualization of multidimensional data through transformation of multidimensional space into two-dimensional space allow to present multidimensional data on computer screen. Among such methods, relevance maps method can be found which was used in this paper to present and analyze set of seven-dimensional data describing coal samples originating from both mines. It was decided to check whether this method of visualization of multidimensional data allows to divide the samples space into subspaces of various usefulness to the process of fluidal gasification or not. The method enables the visualisation of the optimal subspace containing the set requirements concerning the properties of coals intended for this process.

  10. Mentoring Narratives ON-LINE:Teaching the Principalship

    Directory of Open Access Journals (Sweden)

    Allison I. Griffith

    2002-05-01

    Full Text Available The need to develop new models for preparation of school administrators has been a prominent concern in educational discourse in the last decade. Having been criticized for the inadequate preparation of the school leadership cadre, academic departments responsible for training future school administrators have had to revisit their approaches and to reframe their teaching philosophies to ensure the readiness of their graduates for the challenges and complexities of school leadership. This article reports on the new model of principals' training that has been used in York University's Principals' Qualification Program (PQP from the late 1990s onward. One component of the program brings traditional case methodology into a computer-mediated/on-line environment. The on-line cases are narratives from the everyday lives of the Ontario school administrators who serve as mentors in the on-line environment. Situating our discussion within the context of the rapidly changing educational landscape of Ontario, we focus on the PQP model to explore experientially generated case narratives as one method for teaching and learning the work of the local school administrator. We focus particularly on the teaching and learning embedded in computer-mediated or on-line case narratives used in training teachers for school leadership. We argue that the complexities of school leadership—the social, cultural, relational, ethical and moral context of school leadership—can be taught effectively through the reflective processes of on-line case narratives. We seek to contribute to the ongoing dialogue on the potential of new pedagogies and new technologies to help prepare the competent and responsible leaders for tomorrow's schools.

  11. An On-line Assessment System for English-Chinese Translation

    Institute of Scientific and Technical Information of China (English)

    TIAN Yan; LU Ru-zhan; DUAN Jian-yong

    2007-01-01

    On-line assessment of English-Chinese translation is a challenging task as it involves natural language processing. YanFa, an on-line assessment system for English-Chinese translation, is a pilot research project into scoring student's translation on-line. Based on the theory of translation equivalence, an algorithm called "conceptual similarity matching" was developed. YanFa can assess students' translation on-line timely, generate test papers automatically, offer standard versions of translation, and the scores of each sentence to students. The evaluation proves that YanFa is practical compared with the scores given by experts.

  12. S2I techniques for analog sampled-data signal processing

    DEFF Research Database (Denmark)

    Machado, Gerson A. S.; Toumazou, Chris; Saether, Geir E.;

    1996-01-01

    Some recent developments in Analog-Sampled-Data Signal Processing (ASD SP) are reviewed. Following a brief review of the state-of-the-art in switched capacitor (SC) signal processing, the "current mode" switched-current (SI/S2I) technique is presented. New techniques for exploring niches in low v......-chip mixed mode systems implemented in standard digital ULSI/VLSI technologies....

  13. Data Validation Package May 2016 Groundwater Sampling at the Lakeview, Oregon, Processing Site August 2016

    Energy Technology Data Exchange (ETDEWEB)

    Linard, Joshua [USDOE Office of Legacy Management, Washington, DC (United States); Hall, Steve [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-08-01

    This biennial event includes sampling five groundwater locations (four monitoring wells and one domestic well) at the Lakeview, Oregon, Processing Site. For this event, the domestic well (location 0543) could not be sampled because no one was in residence during the sampling event (Note: notification was provided to the resident prior to the event). Per Appendix A of the Groundwater Compliance Action Plan, sampling is conducted to monitor groundwater quality on a voluntary basis. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). One duplicate sample was collected from location 0505. Water levels were measured at each sampled monitoring well. The constituents monitored at the Lakeview site are manganese and sulfate. Monitoring locations that exceeded the U.S. Environmental Protection Agency (EPA) Secondary Maximum Contaminant Levels for these constituents are listed in Table 1. Review of time-concentration graphs included in this report indicate that manganese and sulfate concentrations are consistent with historical measurements.

  14. Faulting processes in active faults - Evidences from TCDP and SAFOD drill core samples

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, C.; Wirth, R.; Wenk, H. -R.; Morales, L.; Naumann, R.; Kienast, M.; Song, S. -R.; Dresen, G. [UCB; (GFZ); (NTU)

    2014-08-20

    The microstructures, mineralogy and chemistry of representative samples collected from the cores of the San Andreas Fault drill hole (SAFOD) and the Taiwan Chelungpu-Fault Drilling project (TCDP) have been studied using optical microscopy, TEM, SEM, XRD and XRF analyses. SAFOD samples provide a transect across undeformed host rock, the fault damage zone and currently active deforming zones of the San Andreas Fault. TCDP samples are retrieved from the principal slip zone (PSZ) and from the surrounding damage zone of the Chelungpu Fault. Substantial differences exist in the clay mineralogy of SAFOD and TCDP fault gouge samples. Amorphous material has been observed in SAFOD as well as TCDP samples. In line with previous publications, we propose that melt, observed in TCDP black gouge samples, was produced by seismic slip (melt origin) whereas amorphous material in SAFOD samples was formed by comminution of grains (crush origin) rather than by melting. Dauphiné twins in quartz grains of SAFOD and TCDP samples may indicate high seismic stress. The differences in the crystallographic preferred orientation of calcite between SAFOD and TCDP samples are significant. Microstructures resulting from dissolution–precipitation processes were observed in both faults but are more frequently found in SAFOD samples than in TCDP fault rocks. As already described for many other fault zones clay-gouge fabrics are quite weak in SAFOD and TCDP samples. Clay-clast aggregates (CCAs), proposed to indicate frictional heating and thermal pressurization, occur in material taken from the PSZ of the Chelungpu Fault, as well as within and outside of the SAFOD deforming zones, indicating that these microstructures were formed over a wide range of slip rates.

  15. Expanding the application of the tablet processing workstation to support the sample preparation of oral suspensions.

    Science.gov (United States)

    Opio, Alex Manuel; Nickerson, Beverly; Xue, Gang; Warzeka, John; Norris, Ken

    2011-06-01

    Sample preparation is the most time-consuming part of the analytical method for powder for oral suspension (POS) assay, purity, and preservative analysis, as this involves multiple dilution and filtration steps. The Tablet Processing Workstation (TPW) was used to automate the sample preparation of a POS formulation. Although the TPW is typically used to automate the preparation of solid oral dosage forms and powders, it contains all of the necessary components to perform POS sample preparation. The TPW exhibited acceptable repeatability in testing 3 lots using 10 replicate preparations per lot. Acceptable linearity of the drug and preservative in the presence of excipients was demonstrated over the range corresponding to 50-150% of intent. Accuracy showed suitable recoveries for all points evaluated. TPW results were shown to correlate to results obtained with the manual method. The TPW method was used to prepare samples in support of manufacturing scale-up efforts. With the efficiencies gained using the TPW, it was possible to analyze a large number of samples generated during process development activities for the POS formulation with minimal human intervention. The extensive data enabled trending of the manufacturing development runs and helped to identify optimization strategies for the process.

  16. Sample processing for DNA chip array-based analysis of enterohemorrhagic Escherichia coli (EHEC

    Directory of Open Access Journals (Sweden)

    Enfors Sven-Olof

    2008-10-01

    Full Text Available Abstract Background Exploitation of DNA-based analyses of microbial pathogens, and especially simultaneous typing of several virulence-related genes in bacteria is becoming an important objective of public health these days. Results A procedure for sample processing for a confirmative analysis of enterohemorrhagic Escherichia coli (EHEC on a single colony with DNA chip array was developed and is reported here. The protocol includes application of fragmented genomic DNA from ultrasonicated colonies. The sample processing comprises first 2.5 min of ultrasonic treatment, DNA extraction (2×, and afterwards additional 5 min ultrasonication. Thus, the total sample preparation time for a confirmative analysis of EHEC is nearly 10 min. Additionally, bioinformatic revisions were performed in order to design PCR primers and array probes specific to most conservative regions of the EHEC-associated genes. Six strains with distinct pathogenic properties were selected for this study. At last, the EHEC chip array for a parallel and simultaneous detection of genes etpC-stx1-stx2-eae was designed and examined. This should permit to sense all currently accessible variants of the selected sequences in EHEC types and subtypes. Conclusion In order to implement the DNA chip array-based analysis for direct EHEC detection the sample processing was established in course of this work. However, this sample preparation mode may also be applied to other types of EHEC DNA-based sensing systems.

  17. Limit theory for the sample autocorrelations and extremes of a GARCH (1,1) process

    NARCIS (Netherlands)

    Mikosch, T; Starica, C

    2000-01-01

    The asymptotic theory for the sample autocorrelations and extremes of a GARCH(I, 1) process is provided. Special attention is given to the case when the sum of the ARCH and GARCH parameters is close to 1, that is, when one is close to an infinite Variance marginal distribution. This situation has be

  18. Determination of the bacterial processes which are sources of nitrous oxide production in marine samples.

    Science.gov (United States)

    Bonin, Patricia; Tamburini, Christian; Michotey, Valerie

    2002-02-01

    Partial denitrification and the initial step of nitrification are the main biological processes which produce nitrous oxide. In order to determine the contribution that these processes have in nitrous oxide production, the efficiency of different inhibitors on nitrifying activity has been tested, and the effect on denitrifying activity has been investigated, using culture strains and natural marine samples. A good nitrification inhibitor should not affect denitrification. A low partial pressure of C2H2 provided the best conditions, inhibiting 75%, Nitrosococcus oceanus (culture sample) and 100% (natural sample) of the nitrifying activity and having only a small inhibitory effect (12%) on denitrifying activity. These conditions have been applied on samples from the dilution plume of the Rhĵne River, an area characterized as a source of nitrous oxide. Using these inhibitors, it has been shown that in this area, incomplete denitrification is the main process producing nitrous oxide in the surface layers at the mouth of the river and in the bottom nepheloid layer, whereas in the marine surface layer the dominant process is nitrification.

  19. Unambiguous range-Doppler LADAR processing using 2 giga-sample-per-second noise waveforms

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Z. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States)]. E-mail: cole@s2corporation.com; Roos, P.A. [Spectrum Lab, Montana State University, P.O. Box 173510, Bozeman, MT 59717 (United States); Berg, T. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Kaylor, B. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Merkel, K.D. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Babbitt, W.R. [Spectrum Lab, Montana State University, P.O. Box 173510, Bozeman, MT 59717 (United States); Reibel, R.R. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States)

    2007-11-15

    We demonstrate sub-nanosecond range and unambiguous sub-50-Hz Doppler resolved laser radar (LADAR) measurements using spectral holographic processing in rare-earth ion doped crystals. The demonstration utilizes pseudo-random-noise 2 giga-sample-per-second baseband waveforms modulated onto an optical carrier.

  20. Aqueous Processing of Atmospheric Organic Particles in Cloud Water Collected via Aircraft Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Boone, Eric J.; Laskin, Alexander; Laskin, Julia; Wirth, Christopher; Shepson, Paul B.; Stirm, Brian H.; Pratt, Kerri A.

    2015-07-21

    Cloud water and below-cloud atmospheric particle samples were collected onboard a research aircraft during the Southern Oxidant and Aerosol Study (SOAS) over a forested region of Alabama in June 2013. The organic molecular composition of the samples was studied to gain insights into the aqueous-phase processing of organic compounds within cloud droplets. High resolution mass spectrometry with nanospray desorption electrospray ionization and direct infusion electrospray ionization were utilized to compare the organic composition of the particle and cloud water samples, respectively. Isoprene and monoterpene-derived organosulfates and oligomers were identified in both the particles and cloud water, showing the significant influence of biogenic volatile organic compound oxidation above the forested region. While the average O:C ratios of the organic compounds were similar between the atmospheric particle and cloud water samples, the chemical composition of these samples was quite different. Specifically, hydrolysis of organosulfates and formation of nitrogen-containing compounds were observed for the cloud water when compared to the atmospheric particle samples, demonstrating that cloud processing changes the composition of organic aerosol.

  1. On-line monitoring and control of animal-cell cultures

    NARCIS (Netherlands)

    Pol, van der J.J.

    1996-01-01


    On-line analysis and control of biotechnological processes is still the stepchild in industry. In general, only parameters as dissolved-oxygen concentration, pH and temperature are controlled on-line. Important parameters as substrate and inhibitor concentrations are only measured

  2. The Anatomy of Program Design for an On-Line Business Management Course

    Science.gov (United States)

    Barger, Bonita

    2008-01-01

    How does one design an on-line course to bridge theory and practice? How can the feedback of on-going stakeholder (student and administration) be incorporated into the design process to enhance quality? This paper presents the theoretical underpinning of designing an on-line management course recognized as best practice for a "well organized…

  3. Marine sediment sample pre-processing for macroinvertebrates metabarcoding: mechanical enrichment and homogenization

    Directory of Open Access Journals (Sweden)

    Eva Aylagas

    2016-10-01

    Full Text Available Metabarcoding is an accurate and cost-effective technique that allows for simultaneous taxonomic identification of multiple environmental samples. Application of this technique to marine benthic macroinvertebrate biodiversity assessment for biomonitoring purposes requires standardization of laboratory and data analysis procedures. In this context, protocols for creation and sequencing of amplicon libraries and their related bioinformatics analysis have been recently published. However, a standardized protocol describing all previous steps (i.e. processing and manipulation of environmental samples for macroinvertebrate community characterization is lacking. Here, we provide detailed procedures for benthic environmental sample collection, processing, enrichment for macroinvertebrates, homogenization, and subsequent DNA extraction for metabarcoding analysis. Since this is the first protocol of this kind, it should be of use to any researcher in this field, having the potential for improvement.

  4. X-Ray Computed Tomography: The First Step in Mars Sample Return Processing

    Science.gov (United States)

    Welzenbach, L. C.; Fries, M. D.; Grady, M. M.; Greenwood, R. C.; McCubbin, F. M.; Zeigler, R. A.; Smith, C. L.; Steele, A.

    2017-01-01

    The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. If the samples are returned, that mission would likely present an opportunity to analyze returned Mars samples within a geologic context on Mars. In addition, it may provide definitive information about the existence of past or present life on Mars. Mars sample return presents unique challenges for the collection, containment, transport, curation and processing of samples [1] Foremost in the processing of returned samples are the closely paired considerations of life detection and Planetary Protection. In order to achieve Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues where sparse martian organic compounds must be reliably analyzed against the contamination background. While reliable analyses will depend on initial clean acquisition and robust documentation of all aspects of developing and managing the cache [2], there needs to be a reliable sample handling and analysis procedure that accounts for a variety of materials which may or may not contain evidence of past or present martian life. A recent report [3] suggests that a defined set of measurements should be made to effectively inform both science and Planetary Protection, when applied in the context of the two competing null hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. The defined measurements would include a phased approach that would be accepted by the community to preserve the bulk of the material, but provide unambiguous science data that can be used and interpreted by various disciplines. Fore-most is the concern that the initial steps would ensure the pristine nature of the samples. Preliminary, non-invasive techniques such as computed X-ray tomography (XCT) have been suggested as the first method to interrogate and

  5. 胶束毛细管电动色谱法在线富集联用技术灵敏检测乳制品和饲料样品中的三聚氰胺%On-line Preconcentration and Sensitive Determination of Melamine in Milk Powder and Animal Feeds Samples by Micellar Electrokinetic Chromatography

    Institute of Scientific and Technical Information of China (English)

    陈新; 袁红萍; 曹玉华; 陈秋

    2011-01-01

    建立了胶束毛细管电泳(MEKC)在线富集技术灵敏检测三聚氰胺的方法,采用场放大进样(FASS)联用胶束扫集(Sweep)测定多种样品中的三聚氰胺.试样用乙腈反复提取3次,在优化实验条件下,三聚氰胺的检测灵敏度提高了约1000倍,检出限由原来的2 mg/L降到1.8 μg/L(S/N=3).本方法用于配方奶粉和动物饲料中三聚氰胺残留的检测,回收率在97.2%~105.0%之间;相对标准偏差均小于4.5%(n=4).本方法具有检测灵敏、方便易行、预处理简单、干扰少,经济环保和适用范围广等优点.%A sensitive analytical method using micellar electrokinetic chromatography with on-line pre-concentration technique was developed for rapid determination of melamine in various samples. Two online preconcentration techniques including field-amplified sample stacking and sweeping micellar electrokinetic chromatographic technique (FASS- sweep MEKC) were used. The samples were extracted by acetonitrile for three times. Under the optimum conditions, the sensitivity was improved about 1000 times. The LODs was decreased from 2. 0 mg/L to 1. 8 μg/L. The RSD were less than 4. 5%. The recoveries were range in 97. 2% -105%. This method is sensitive, reliable, economic and . pretreatment-free for complex samples' and can be easily used for product quality control of milk powder and animal feeds.

  6. Educational On-Line Gaming Propensity

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana; Kirchner, Kathrin

    2014-01-01

    Educational on-line games are promising for new generations of students who are grown up digital. Th e new generations of students are technology savvy and spend lots of time on the web and on social networks. Based on an exploratory study, this article investigates the factors that infl uence...... students’ willingness to participate in serious games for teaching/learning. Th is study investigates the relationship between students’ behavior on Facebook, Facebook games, and their attitude toward educational on-line games. Th e results of the study reveal that the early adopters of educational games...... are likely to be students, who are young, have only a few Facebook connections, who currently play Facebook game(s). Furthermore, the study emphasizes that there may be differences between students coming from various countries....

  7. An on-line remote supervisory system for microparticles based on image analysis

    Institute of Scientific and Technical Information of China (English)

    LIU Wei-hua; JIANG Ming-shun; SUI Qing-mei

    2011-01-01

    A new on-line remote particle analysis system based on image processing has been developed to measure microparticles.The system is composed of particle collector sensor (PCS),particle image sensor (PIS),image remote wansmit module and image processing system.Then some details of image processing are discussed.The main advantage of this system is more convenient in particle sample collection and particle image acquisition.The particle size can be obtained using the system with a deviation abot less than 1 μm,and the particle number can be obtained without deviation,The developed system is also convenient and versatile for other analyses of microparticle for academic and industrial application.

  8. Flexible Sampling of Discrete Scale Invariant Markov Processes: Covariance and Spectrum

    CERN Document Server

    Modarresi, N

    2010-01-01

    In this paper we consider some flexible discrete sampling of a discrete scale invariant process $\\{X(t), t\\in{\\bf R^+}\\}$ with scale $l>1$. By this method we plan to have $q$ samples at arbitrary points ${\\bf s}_0, {\\bf s}_1,..., {\\bf s}_{q-1}$ in interval $[1, l)$ and proceed our sampling in the intervals $[l^n, l^{n+1})$ at points $l^n{\\bf s}_0, l^n{\\bf s}_1,..., l^n{\\bf s}_{q-1}$, $n\\in {\\bf Z}$. Thus we have a discrete time scale invariant (DT-SI) process and introduce an embedded DT-SI process as $W(nq+k)=X(l^n{\\bf s}_k)$, $q\\in {\\bf N}$, $k= 0,..., q-1$. We also consider $V(n)=\\big(V^0(n),..., V^{q-1}(n)\\big)$ where $V^k(n)=W(nq+k)$, as an embedded $q$-dimensional discrete time self-similar (DT-SS) process. By introducing quasi Lamperti transformation, we find spectral representation of such process and its spectral density matrix is given. Finally by imposing wide sense Markov property for $W(\\cdot)$ and $V(\\cdot)$, we show that the spectral density matrix of $V(\\cdot)$ and spectral density function of...

  9. The Task Manager for the LHCb On-Line Farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2004-01-01

    The Task Manager is a utility to start, stop and list processes on the on-line farm. Each process started by the Task Manager has a string environment variable set, named UTGID (User defined unique Thread Group Identifier) which allows to identify the process. The Task Manager uses the UTGID to list the running processes and to identify the processes to be stopped. It has also the ability to start a process using a particular user name and to set the scheduler type and the priority for the process itself. The Task Manager package includes a Linux DIM server (tmSrv), four Linux command line DIM clients (tmStart, tmLs, tmKill and tmStop) and a JCOP (Joint Control Project) PVSS client.

  10. Lévy matters Lévy-type processes construction, approximation and sample path properties

    CERN Document Server

    Böttcher, Björn; Wang, Jian

    2013-01-01

    This volume presents recent developments in the area of Lévy-type processes and more general stochastic processes that behave locally like a Lévy process. Although written in a survey style, quite a few results are extensions of known theorems, and others are completely new. The focus is on the symbol of a Lévy-type process: a non-random function which is the counterpart of the characteristic exponent of a Lévy process. The class of stochastic processes which can be associated with a symbol is characterized, various schemes constructing a stochastic process from a given symbol are discussed, and it is shown how one can use the symbol in order to describe the sample path properties of the underlying process. Lastly, the symbol is used to approximate and simulate Levy-type processes. This is the third volume in a subseries of the Lecture Notes in Mathematics called Lévy Matters. Each volume describes a number of important topics in the theory or applications of Lévy processes and pays tribute to the stat...

  11. Sheet metal hardening curve determined by laminated sample and its adaptability to sheet forming processes

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The hardening curve for sheet metal can be determined from the load-displacement curve of tensilespecimen with rectangular cross-section. Therefore, uniaxial compression test on cylinder specimen made from laminated sample is put forward. Considering the influence of anisotropy on hardening properties and the stress state in popular forming process, plane strain compression test on cubic specimen made from laminated sample was advanced. Results show that the deformation range of hardening curves obtained from the presented methods is wide, which meets the need for the application in sheet metal forming processes. In view of the characteristics of methods presented in the paper and the stress strain state of various forming processes, the adaptability of the two methods presented in this paper is given.

  12. Connecting to On-line Data

    Science.gov (United States)

    Eichhorn, G.; Astrophysics Datacenter Executive Committee (ADEC)

    2004-05-01

    The Astrophysics Datacenter Executive Committee (ADEC) is coordinating the development of a system to facilitate the linking to on-line data. This system has three components: 1. Unique dataset identifiers. 2. A verification system for identifiers. 3. Permanent links to on-line data sets. 1. The ADEC has agreed on a naming scheme for data sets that allows for the unique identification of any data set. The ADEC data centers will clearly mark their data with these identifiers to allow the generation of links to these data. 2. Each data center has a utility that can check whether a data set identifier is a valid identifier at that center. A central verifier allows third parties access to these individual verifiers through a single portal. 3. The central verifier also provides permanent links to data sets through a central link forwarding system. This makes it possible to move data sets between data centers while maintaining the permanent links. The ADEC plans to first use this system to implement the linking from the literature to on-line data in a collaboration with the AAS and the University of Chicago Press for the AAS journals.

  13. Statistical Review of Data from DWPF's Process Samples for Batches 19 Through 30

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T.B.

    1999-04-06

    The measurements derived from samples taken during the processing of batches 19 through 30 at the Defense Waste Processing Facility (DWPF) affords an opportunity for review and comparisons. This report has looked at some of the statistics from these data. Only the data reported by the DWPF lab (that is, the data provided by the lab as representative of the samples taken) are available for this analysis. In some cases, the sample results reported may be a subset of the sample results generated by the analytical procedures. A thorough assessment of the DWPF lab's analytical procedures would require the complete set of data. Thus, the statistics reported here, specifically, as they relate to analytical uncertainties, are limited to the reported data for these samples, A fell for the consistency of the incoming slurry is the estimation of the components of variation for the Sludge Receipt and Adjustment Tank (SRAT) receipts. In general, for all of the vessels, the data from batches after 21 show smaller batch-to-batch variation than the data from all the batches. The relative contributions of batch-to-batch versus residual, which includes analytical, are presented in these analyses.

  14. A comparison between data processing techniques for FTS based on high frequency interferogram sampling

    Science.gov (United States)

    Panzeri, R.; Saggin, S.; Scaccabarozzi, D.; Tarabini, M.

    2016-10-01

    This paper compares different data processing techniques for FTS with the aim of assessing the feasibility of a spectrometer leveraging on standard DAC boards, without dedicated hardware for sampling and speed control of the moving mirrors. Fourier transform spectrometers rely on the sampling of the interferogram at constant steps of the optical path difference (OPD) to evaluate the spectra through standard discrete Fourier transform. Constant OPD sampling is traditionally achieved with dedicated hardware but, recently, sampling methods based on the use of common analog to digital converters with large dynamic range and high sampling frequency have become viable when associated with specific data processing techniques. These methods offer advantages from the point of view of insensitivity to disturbances, in particular mechanical vibrations, and should be less sensitive to OPD speed errors. In this work the performances of three algorithms, two taken from literature based on phase demodulation of a reference interferogram have been compared with a method based on direct phase computation of the reference interferogram in terms of robustness against mechanical vibrations and OPD speed errors. All methods provided almost correct spectra with vibrations amplitudes up to 10% of the average OPD speed and speed drifts within the scan up to 20% of the average, as long as the disturbance frequency was lower than the reference signal nominal one. The developed method based on the arccosine function keeps working also with frequencies of the disturbances larger than the reference channel one, the common limit for the other two.

  15. Technical note: Sampling and processing of mesocosm sediment trap material for quantitative biogeochemical analysis

    Science.gov (United States)

    Boxhammer, Tim; Bach, Lennart T.; Czerny, Jan; Riebesell, Ulf

    2016-05-01

    Sediment traps are the most common tool to investigate vertical particle flux in the marine realm. However, the spatial and temporal decoupling between particle formation in the surface ocean and particle collection in sediment traps at depth often handicaps reconciliation of production and sedimentation even within the euphotic zone. Pelagic mesocosms are restricted to the surface ocean, but have the advantage of being closed systems and are therefore ideally suited to studying how processes in natural plankton communities influence particle formation and settling in the ocean's surface. We therefore developed a protocol for efficient sample recovery and processing of quantitatively collected pelagic mesocosm sediment trap samples for biogeochemical analysis. Sedimented material was recovered by pumping it under gentle vacuum through a silicon tube to the sea surface. The particulate matter of these samples was subsequently separated from bulk seawater by passive settling, centrifugation or flocculation with ferric chloride, and we discuss the advantages and efficiencies of each approach. After concentration, samples were freeze-dried and ground with an easy to adapt procedure using standard lab equipment. Grain size of the finely ground samples ranged from fine to coarse silt (2-63 µm), which guarantees homogeneity for representative subsampling, a widespread problem in sediment trap research. Subsamples of the ground material were perfectly suitable for a variety of biogeochemical measurements, and even at very low particle fluxes we were able to get a detailed insight into various parameters characterizing the sinking particles. The methods and recommendations described here are a key improvement for sediment trap applications in mesocosms, as they facilitate the processing of large amounts of samples and allow for high-quality biogeochemical flux data.

  16. [Spectral analysis of elements in different samples of processed Foeniculum vulgare].

    Science.gov (United States)

    Zhang, Fan; Li, Zhen; Hamulati, Wufuer; Tian, Shu-Ge

    2010-03-01

    The compositions and contents of chemical compounds in traditional Chinese medicines would be changed after being processed using different methods, and their pharmacological activity may be influenced. ICP-AES, AAS and AFS were the first methods to be used to scan and analyze macro elements, trace elements and heavy metals in Foeniculum vulgare and its nine different processed samples in the present paper, which were correlated with people's health and lives. The experiment results showed that the three kinds of analyzing methods could be used to judge the contents and the changing trend of all elements in traditional Chinese medicine quickly and truly. Thirty two elements were found in F. vulgare, and there were noticeable changes in the contents of some elements in processed samples compared with F. vulgare without processing. These results indicated that there is great relevance between changes in the contends of elements with different processing methods, and auxiliary materials can not only change the contents of elements but also play a role in treating ills with effective constituents. Also, it was firstly found that the content of Hg rose greatly in the experiment, and these showed there was notable potential safety hazard when processed Foeniculum vulgare was used. These experiments widen the application of spectrum analyzing methods in safety evaluation of traditional Chinese medicine.

  17. Removal of Pb ion from water samples using red mud (bauxite ore processing waste)

    OpenAIRE

    Ghorbani A.; Nazarfakhari M.; Pourasad Y.; Mesgari Abbasi S.

    2014-01-01

    This work presented the use of red mud (bauxite ore processing waste) in removal of lead ions in water samples. For this 0.1 g of red mud has been used as adsorbent which suspended in 10 ml of lead solution with the concentration of 50 mg l-1 for about 1 h. After that the lead concentration in the samples taken from the red mud treated lead solution measured with atomic absorption spectroscopy (AAS). The effect of some parameter which is important in adsorption of lead on red mud such as suit...

  18. Application of Near-infrared Spectroscopy On -line Detection to Production Process of Atractylodes Japonica Extract%关苍术提取过程中近红外在线检测模型建立研究

    Institute of Scientific and Technical Information of China (English)

    张海波; 张瑞; 傅禹砜; 丁秀峰; 王英平

    2013-01-01

    Using near-infrared (NIR) spectroscopy to obtain the spectrum of atractylodes japonica sample ,and the atractylodin contents of the sample determined by colorimetric method .The sample contents 64 atractylodes japonica powders in different origin places and years ,and 128 extract solutions derived from the powders .Using partial least squares (PLS ) ,the calibration models were developed to correlate near infrared spectra and atractylodin contents .Using cross-validation evaluating the models ,the results showed:the correlation coefficients of model were 90.68 and 95.71 ,the root mean square error of cross-validation(RMSECV) values were 0.011 2 and 0.020 0 ,ratio of deviation to perfor-mances(RPD) of model finally developed were 3.43 and 3.86 respectively .The model achieved the best prediction performance ,and there is no significant difference between predictive contents and chemical values .The results indicated that NIR spectroscopy could be used in practice to fast determine the atractylodin contents of powder and extract solutions .%采用比色法和近红外漫反射、液体透射在线检测技术,分别测定64个关苍术原材料固体样品和128个关苍术提取液样品的苍术素含量和近红外光谱,结合偏最小二乘回归法,建立样品苍术素含量与近红外光谱之间的数学模型。采用内部交叉检验对模型进行评价,评价结果显示,决定系数 R2为90.68、95.71,交叉检验均方差(RMSECV )值分别为0.0112、0.0200,相对分析误差(RPD )分别为3.43、3.86。模型评价数据均有较好的表现,原材料、提取液检验样品近红外测定结果与化学参考值之间无显著性差异,近红外检测技术可以应用于关苍术原材料固体样品和关苍术提取液样品中苍术素含量的在线检测。

  19. Calculating of river water quality sampling frequency by the analytic hierarchy process (AHP).

    Science.gov (United States)

    Do, Huu Tuan; Lo, Shang-Lien; Phan Thi, Lan Anh

    2013-01-01

    River water quality sampling frequency is an important aspect of the river water quality monitoring network. A suitable sampling frequency for each station as well as for the whole network will provide a measure of the real water quality status for the water quality managers as well as the decision makers. The analytic hierarchy process (AHP) is an effective method for decision analysis and calculation of weighting factors based on multiple criteria to solve complicated problems. This study introduces a new procedure to design river water quality sampling frequency by applying the AHP. We introduce and combine weighting factors of variables with the relative weights of stations to select the sampling frequency for each station, monthly and yearly. The new procedure was applied for Jingmei and Xindian rivers, Taipei, Taiwan. The results showed that sampling frequency should be increased at high weighted stations while decreased at low weighted stations. In addition, a detailed monitoring plan for each station and each month could be scheduled from the output results. Finally, the study showed that the AHP is a suitable method to design a system for sampling frequency as it could combine multiple weights and multiple levels for stations and variables to calculate a final weight for stations, variables, and months.

  20. Molecularly imprinted polymers for on-line extraction techniques.

    Science.gov (United States)

    Moein, Mohammad M; Abdel-Rehim, Mohamed

    2015-01-01

    Recent years have seen an increasing interest in the use of molecularly imprinted polymers (MIPs) as a sorbent for different extraction methods and this is due to its high selectivity. The MIP is designed to show specificity for the analyte of interest. Moreover, MIPs show physical robustness, resistance to high temperatures and pressures, and stability in the presence of acids, bases and a wide range of organic solvents. In the present article, various novel sample preparation techniques which MIPs applied as sorbent and on-line connected with analytical instruments were highlighted and discussed. The future aspects of MIPs as well were described.

  1. On-line chemical composition analyzer development. Phase 2, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, M.J.; Garrison, A.A.; Muly, E.C.; Moore, C.F.

    1992-02-01

    The energy consumed in distillation processes in the United States represents nearly three percent of the total national energy consumption. If effective control of distillation columns can be accomplished, it has been estimated that it would result in a reduction in the national energy consumption of 0.3%. Real-time control based on mixture composition could achieve these savings. However, the major distillation processes represent diverse applications and at present there does not exist a proven on-line chemical composition sensor technology which can be used to control these diverse processes in real-time. This report presents a summary of the findings of the second phase of a three phase effort undertaken to develop an on-line real-time measurement and control system utilizing Raman spectroscopy. A prototype instrument system has been constructed utilizing a Perkin Elmer 1700 Spectrometer, a diode pumped YAG laser, two three axis positioning systems, a process sample cell land a personal computer. This system has been successfully tested using industrially supplied process samples to establish its performance. Also, continued application development was undertaken during this Phase of the program using both the spontaneous Raman and Surface-enhanced Raman modes of operation. The study was performed for the US Department of Energy, Office of Industrial Technologies, whose mission is to conduct cost-shared R&D for new high-risk, high-payoff industrial energy conservation technologies. Although this document contains references to individual manufacturers and their products, the opinions expressed on the products reported do not necessarily reflect the position of the Department of Energy.

  2. Visibility graph analysis for re-sampled time series from auto-regressive stochastic processes

    Science.gov (United States)

    Zhang, Rong; Zou, Yong; Zhou, Jie; Gao, Zhong-Ke; Guan, Shuguang

    2017-01-01

    Visibility graph (VG) and horizontal visibility graph (HVG) play a crucial role in modern complex network approaches to nonlinear time series analysis. However, depending on the underlying dynamic processes, it remains to characterize the exponents of presumably exponential degree distributions. It has been recently conjectured that there is a critical value of exponent λc = ln 3 / 2 , which separates chaotic from correlated stochastic processes. Here, we systematically apply (H)VG analysis to time series from autoregressive (AR) models, which confirms the hypothesis that an increased correlation length results in larger values of λ > λc. On the other hand, we numerically find a regime of negatively correlated process increments where λ < λc, which is in contrast to this hypothesis. Furthermore, by constructing graphs based on re-sampled time series, we find that network measures show non-trivial dependencies on the autocorrelation functions of the processes. We propose to choose the decorrelation time as the maximal re-sampling delay for the algorithm. Our results are detailed for time series from AR(1) and AR(2) processes.

  3. The possibility of the boronizing process on the pressed samples of iron powder

    Directory of Open Access Journals (Sweden)

    Požega Emina D.

    2009-01-01

    Full Text Available The paper presents results of the experimental investigation of the boronizing process on nonsintering iron powder samples (NC100.24, Höganäs, Sweden. Experiments are planned within the limits of applicability of simultaneous sintering at chemical-thermal treatment process (boronizing. The simlex plan of 15 experimental points was used for the experiment, while a polynomial function of fourth degree was employed in the modeling of a mixture composition based on the volume changes, porosity and the depth layer changes. Boronizing was carried out in mixture with born carbide by addition of ammonium bifluoride, ammonium chloride and boron potassium fluoride as activators, by proportion definited plan.

  4. S2I techniques for analog sampled-data signal processing

    DEFF Research Database (Denmark)

    Machado, Gerson A. S.; Toumazou, Chris; Saether, Geir E.

    1996-01-01

    Some recent developments in Analog-Sampled-Data Signal Processing (ASD SP) are reviewed. Following a brief review of the state-of-the-art in switched capacitor (SC) signal processing, the "current mode" switched-current (SI/S2I) technique is presented. New techniques for exploring niches in low...... voltage, low current, tuneable systems or very high speed BiCMOS and GaAs circuits are introduced with reference to current work, and some design suggestions are given for further circuit implementations. The S2I technique is maturing quickly, offering a potential cost/performance advantage for single...

  5. Automated processing of whole blood samples into microliter aliquots of plasma

    OpenAIRE

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 μl can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially i...

  6. SAUNA—a system for automatic sampling, processing, and analysis of radioactive xenon

    Science.gov (United States)

    Ringbom, A.; Larson, T.; Axelsson, A.; Elmgren, K.; Johansson, C.

    2003-08-01

    A system for automatic sampling, processing, and analysis of atmospheric radioxenon has been developed. From an air sample of about 7 m3 collected during 12 h, 0.5 cm3 of xenon is extracted, and the atmospheric activities from the four xenon isotopes 133Xe, 135Xe, 131mXe, and 133mXe are determined with a beta-gamma coincidence technique. The collection is performed using activated charcoal and molecular sieves at ambient temperature. The sample preparation and quantification are performed using preparative gas chromatography. The system was tested under routine conditions for a 5-month period, with average minimum detectable concentrations below 1 mBq/ m3 for all four isotopes.

  7. Robowell: An automated process for monitoring ground water quality using established sampling protocols

    Science.gov (United States)

    Granato, G.E.; Smith, K.P.

    1999-01-01

    Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

  8. A 32-channel waveform sampling FASTBUS module with local DSP processing

    Energy Technology Data Exchange (ETDEWEB)

    Wixted, R.L. [Princeton Univ., NJ (United States). Dept. of Physics; Chidzik, S. [Princeton Univ., NJ (United States). Dept. of Physics; Marlow, D.R. [Princeton Univ., NJ (United States). Dept. of Physics; Mindas, C.R. [Princeton Univ., NJ (United States). Dept. of Physics; Sekikawa, S. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305 (Japan); Arai, I. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305 (Japan); Suzuki, A. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305 (Japan); Watanabe, A. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305 (Japan); Kuno, Y. [Department of Physics, National Laboratory for High Energy Physics (KEK), Tsukuba, Ibaraki 305 (Japan)

    1997-02-21

    A 32-channel FASTBUS module that uses switched-capacitor arrays to sample and store input waveforms at rates up to 30 MHz is described. The captured data are digitized using commercial 12-bit analog-to-digital converters and are routed to an array of dual port memories. The data in the dual port memories can be readout directly over the FASTBUS backplane or can be subjected to further processing by a digital signal processor mounted on the FASTBUS auxiliary card. (orig.).

  9. Sample processing for DNA chip array-based analysis of enterohemorrhagic Escherichia coli (EHEC)

    OpenAIRE

    Enfors Sven-Olof; Wegrzyn Grzegorz; Basselet Pascal; Gabig-Ciminska Magdalena

    2008-01-01

    Abstract Background Exploitation of DNA-based analyses of microbial pathogens, and especially simultaneous typing of several virulence-related genes in bacteria is becoming an important objective of public health these days. Results A procedure for sample processing for a confirmative analysis of enterohemorrhagic Escherichia coli (EHEC) on a single colony with DNA chip array was developed and is reported here. The protocol includes application of fragmented genomic DNA from ultrasonicated co...

  10. Preliminary study of the EChO data sampling and processing

    Science.gov (United States)

    Farina, M.; Di Giorgio, A. M.; Focardi, M.; Pace, E.; Micela, G.; Galli, E.; Giusi, G.; Liu, S. J.; Pezzuto, S.

    2014-08-01

    The EChO Payload is an integrated spectrometer with six different channels covering the spectral range from the visible up to the thermal infrared. A common Instrument Control Unit (ICU) implements all the instrument control and health monitoring functionalities as well as all the onboard science data processing. To implement an efficient design of the ICU on board software, separate analysis of the unit requirements are needed for the commanding and housekeeping collection as well as for the data acquisition, sampling and compression. In this work we present the results of the analysis carried out to optimize the EChO data acquisition and processing chain. The HgCdTe detectors used for EChO mission allow for non-destructive readout modes, such that the charge may be read without removing it after reading out. These modes can reduce the equivalent readout noise and the gain in signal to noise ratio can be computed using well known relations based on fundamental principles. In particular, we considered a multiaccumulation approach based on non-destructive reading of detector samples taken at equal time intervals. All detectors are periodically reset after a certain number of samples have been acquired and the length of the reset interval, as well as the number of samples and the sampling rate can be adapted to the brightness of the considered source. The estimation of the best set of parameters for the signal to noise ratio optimization and of the best sampling technique has been done by taking into account also the needs of mitigating the expected radiation effects on the acquired data. Cosmic rays can indeed be one of the major sources of data loss for a space observatory, and the studies made for the JWST mission allowed us to evaluate the actual need of the implementation of a dedicated deglitching procedure on board EChO.

  11. Universal microfluidic automaton for autonomous sample processing: application to the Mars Organic Analyzer.

    Science.gov (United States)

    Kim, Jungkyu; Jensen, Erik C; Stockton, Amanda M; Mathies, Richard A

    2013-08-20

    A fully integrated multilayer microfluidic chemical analyzer for automated sample processing and labeling, as well as analysis using capillary zone electrophoresis is developed and characterized. Using lifting gate microfluidic control valve technology, a microfluidic automaton consisting of a two-dimensional microvalve cellular array is fabricated with soft lithography in a format that enables facile integration with a microfluidic capillary electrophoresis device. The programmable sample processor performs precise mixing, metering, and routing operations that can be combined to achieve automation of complex and diverse assay protocols. Sample labeling protocols for amino acid, aldehyde/ketone and carboxylic acid analysis are performed automatically followed by automated transfer and analysis by the integrated microfluidic capillary electrophoresis chip. Equivalent performance to off-chip sample processing is demonstrated for each compound class; the automated analysis resulted in a limit of detection of ~16 nM for amino acids. Our microfluidic automaton provides a fully automated, portable microfluidic analysis system capable of autonomous analysis of diverse compound classes in challenging environments.

  12. Towards a Theory of Sampled-Data Piecewise-Deterministic Markov Processes

    Science.gov (United States)

    Herencia-Zapana, Heber; Gonzalez, Oscar R.; Gray, W. Steven

    2006-01-01

    The analysis and design of practical control systems requires that stochastic models be employed. Analysis and design tools have been developed, for example, for Markovian jump linear continuous and discrete-time systems, piecewise-deterministic processes (PDP's), and general stochastic hybrid systems (GSHS's). These model classes have been used in many applications, including fault tolerant control and networked control systems. This paper presents initial results on the analysis of a sampled-data PDP representation of a nonlinear sampled-data system with a jump linear controller. In particular, it is shown that the state of the sampled-data PDP satisfies the strong Markov property. In addition, a relation between the invariant measures of a sampled-data system driven by a stochastic process and its associated discrete-time representation are presented. As an application, when the plant is linear with no external input, a sufficient testable condition for the convergence in distribution to the invariant delta Dirac measure is given.

  13. A Pipeline for Large Data Processing Using Regular Sampling for Unstructured Grids

    Energy Technology Data Exchange (ETDEWEB)

    Berres, Anne Sabine [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Adhinarayanan, Vignesh [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States); Turton, Terece [Univ. of Texas, Austin, TX (United States); Feng, Wu [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States); Rogers, David Honegger [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-12

    Large simulation data requires a lot of time and computational resources to compute, store, analyze, visualize, and run user studies. Today, the largest cost of a supercomputer is not hardware but maintenance, in particular energy consumption. Our goal is to balance energy consumption and cognitive value of visualizations of resulting data. This requires us to go through the entire processing pipeline, from simulation to user studies. To reduce the amount of resources, data can be sampled or compressed. While this adds more computation time, the computational overhead is negligible compared to the simulation time. We built a processing pipeline at the example of regular sampling. The reasons for this choice are two-fold: using a simple example reduces unnecessary complexity as we know what to expect from the results. Furthermore, it provides a good baseline for future, more elaborate sampling methods. We measured time and energy for each test we did, and we conducted user studies in Amazon Mechanical Turk (AMT) for a range of different results we produced through sampling.

  14. On-line determination of anions in pulp mills by capillary electrophoresis (CE); Tehdasoloissa tapahtuva anionien kapillaarielektroforeettinen on-line maeaeritys ja sen hyoedyntaeminen prosessivalvonnassa - MPKY 02

    Energy Technology Data Exchange (ETDEWEB)

    Kokkonen, R.; Holmberg, M.; Vainikka, V. [Finnish Pulp and Paper Research Institute, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up a process control system for on-line measurement of certain anions. Typical anions which forms precipitates in pulp and paper mills are oxalate, carbonate and sulphate. Thus it is important to develop a continuous process analyzing system to control concentration levels of this anions. For the preliminary tests of continuous determinations of chloride and sulphate anions in tap water a simple on-line system was build in KCL (The Finnish Pulp and Paper Research Institute) and connected to a capillary electroforesis apparatus. In the preliminary tests a chromate buffer (ph = 7.6) was used. Separation of chloride and sulphate was excellent but the stability of buffer was not good enough and it was usable only for few hours. After experimental studies VTT developed a stable capillary electrophoresis method based on mixed amine buffer and this was selected for an on-line method for determination of anions in process waters of the pulp and paper industry. In the preliminary on-line test (r = 20) repeatabilities of migration times of sulphate and chloride with the chromate buffer were < 5 % (RSD) and peak heights < 15 % (RSD). With the mixed amine buffer repeatabilities were better. The preliminary tests showed that it is possible to connect a capillary electrophoresis system to on-line measurements. For the moment no commercial on-line CE apparatus is available. (orig.)

  15. Microwave processing for sample preparation to evaluate mitochondrial ultrastructural damage in hemorrhagic shock.

    Science.gov (United States)

    Josephsen, Gary D; Josephsen, Kelly A; Beilman, Greg J; Taylor, Jodie H; Muiler, Kristine E

    2005-12-01

    This is a report of the adaptation of microwave processing in the preparation of liver biopsies for transmission electron microscopy (TEM) to examine ultrastructural damage of mitochondria in the setting of metabolic stress. Hemorrhagic shock was induced in pigs via 35% total blood volume bleed and a 90-min period of shock followed by resuscitation. Hepatic biopsies were collected before shock and after resuscitation. Following collection, biopsies were processed for TEM by a rapid method involving microwave irradiation (Giberson, 2001). Samples pre- and postshock of each of two animals were viewed and scored using the mitochondrial ultrastructure scoring system (Crouser et al., 2002), a system used to quantify the severity of ultrastructural damage during shock. Results showed evidence of increased ultrastructural damage in the postshock samples, which scored 4.00 and 3.42, versus their preshock controls, which scored 1.18 and 1.27. The results of this analysis were similar to those obtained in another model of shock (Crouser et al., 2002). However, the amount of time used to process the samples was significantly shortened with methods involving microwave irradiation.

  16. Gaussian process based intelligent sampling for measuring nano-structure surfaces

    Science.gov (United States)

    Sun, L. J.; Ren, M. J.; Yin, Y. H.

    2016-09-01

    Nanotechnology is the science and engineering that manipulate matters at nano scale, which can be used to create many new materials and devices with a vast range of applications. As the nanotech product increasingly enters the commercial marketplace, nanometrology becomes a stringent and enabling technology for the manipulation and the quality control of the nanotechnology. However, many measuring instruments, for instance scanning probe microscopy, are limited to relatively small area of hundreds of micrometers with very low efficiency. Therefore some intelligent sampling strategies should be required to improve the scanning efficiency for measuring large area. This paper presents a Gaussian process based intelligent sampling method to address this problem. The method makes use of Gaussian process based Bayesian regression as a mathematical foundation to represent the surface geometry, and the posterior estimation of Gaussian process is computed by combining the prior probability distribution with the maximum likelihood function. Then each sampling point is adaptively selected by determining the position which is the most likely outside of the required tolerance zone among the candidates and then inserted to update the model iteratively. Both simulationson the nominal surface and manufactured surface have been conducted on nano-structure surfaces to verify the validity of the proposed method. The results imply that the proposed method significantly improves the measurement efficiency in measuring large area structured surfaces.

  17. A Variable Sampling Interval Synthetic Xbar Chart for the Process Mean.

    Directory of Open Access Journals (Sweden)

    Lei Yong Lee

    Full Text Available The usual practice of using a control chart to monitor a process is to take samples from the process with fixed sampling interval (FSI. In this paper, a synthetic X control chart with the variable sampling interval (VSI feature is proposed for monitoring changes in the process mean. The VSI synthetic X chart integrates the VSI X chart and the VSI conforming run length (CRL chart. The proposed VSI synthetic X chart is evaluated using the average time to signal (ATS criterion. The optimal charting parameters of the proposed chart are obtained by minimizing the out-of-control ATS for a desired shift. Comparisons between the VSI synthetic X chart and the existing X, synthetic X, VSI X and EWMA X charts, in terms of ATS, are made. The ATS results show that the VSI synthetic X chart outperforms the other X type charts for detecting moderate and large shifts. An illustrative example is also presented to explain the application of the VSI synthetic X chart.

  18. Efficiently Sampling Multiplicative Attribute Graphs Using a Ball-Dropping Process

    CERN Document Server

    Yun, Hyokun

    2012-01-01

    We introduce a novel and efficient sampling algorithm for the Multiplicative Attribute Graph Model (MAGM - Kim and Leskovec (2010)}). Our algorithm is \\emph{strictly} more efficient than the algorithm proposed by Yun and Vishwanathan (2012), in the sense that our method extends the \\emph{best} time complexity guarantee of their algorithm to a larger fraction of parameter space. Both in theory and in empirical evaluation on sparse graphs, our new algorithm outperforms the previous one. To design our algorithm, we first define a stochastic \\emph{ball-dropping process} (BDP). Although a special case of this process was introduced as an efficient approximate sampling algorithm for the Kronecker Product Graph Model (KPGM - Leskovec et al. (2010)}), neither \\emph{why} such an approximation works nor \\emph{what} is the actual distribution this process is sampling from has been addressed so far to the best of our knowledge. Our rigorous treatment of the BDP enables us to clarify the rational behind a BDP approximatio...

  19. Synthetic control charts with two-stage sampling for monitoring bivariate processes

    Directory of Open Access Journals (Sweden)

    Antonio F. B. Costa

    2007-04-01

    Full Text Available In this article, we consider the synthetic control chart with two-stage sampling (SyTS chart to control bivariate processes. During the first stage, one item of the sample is inspected and two correlated quality characteristics (x;y are measured. If the Hotelling statistic T1² for these individual observations of (x;y is lower than a specified value UCL1 the sampling is interrupted. Otherwise, the sampling goes on to the second stage, where the remaining items are inspected and the Hotelling statistic T2² for the sample means of (x;y is computed. When the statistic T2² is larger than a specified value UCL2, the sample is classified as nonconforming. According to the synthetic control chart procedure, the signal is based on the number of conforming samples between two neighbor nonconforming samples. The proposed chart detects process disturbances faster than the bivariate charts with variable sample size and it is from the practical viewpoint more convenient to administer.Este artigo apresenta um gráfico de controle com regra especial de decisão e amostragens em dois estágios para o monitoramento de processos bivariados. No primeiro estágio, um item da amostra é inspecionado e duas características de qualidade correlacionadas (x;y são medidas. Se a estatística de Hotelling T1² para as observações individuais de (x;y for menor que um valor especificado UCL1 a amostragem é interrompida. Caso contrário, a amostragem segue para o segundo estágio, onde os demais itens da amostra são inspecionados e a estatística de Hotelling T2² para as médias de (x;y é calculada. Quando a estatística T2² é maior que um valor especificado UCL2, a amostra é classificada como não conforme. De acordo com a regra especial de decisão, o alarme é baseado no número de amostras entre duas não conformes. O gráfico proposto é mais ágil e mais simples do ponto de vista operacional que o gráfico de controle bivariado com tamanho de amostras variável.

  20. Microstructural evolution in multiseeded YBCO bulk samples grown by the TSMG process

    Science.gov (United States)

    Goodfellow, A.; Shi, Y.-H.; Durrell, J. H.; Dennis, A. R.; Cardwell, D. A.; Grovenor, C. R. M.; Speller, S. C.

    2016-11-01

    Superconducting single-grain YBCO bulk samples with the ability to trap high magnetic fields can be grown using the top-seeded melt-growth process. Multiseeding techniques have the potential to enable larger diameter bulks to be grown, but the performance of these materials is not yet comparable to the single-seeded bulks. Here we carry out detailed three-dimensional microstructural characterisation on a multiseeded sample grown with the seeds aligned in the 0°-0° geometry using high resolution microanalysis techniques. Chemical and structural variations have been correlated with the trapped field distribution in three separate slices of the sample. The top slice of the sample shows four peaks in trapped field, indicating that the current flows in four separate loops rather than in one large loop within the sample. This has been explained by the build-up in insulating Y-211 particles where the growth fronts from the two seeds meet, forming a barrier to current flow, as well as the low Y-211 content (and hence low J c) of the large c-axis growth sector.

  1. On-line evaluating on quality of mild steel joints in resistance spot welding

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A method was developed to realize quality evaluation on every weld-spot in resistance spot welding based on information processing of artificial intelligent. Firstly, the signals of welding current and welding voltage, as information source, were synchronously collected. Input power and dynamic resistance were selected as monitoring waveforms. Eight characteristic parameters relating to weld quality were extracted from the monitoring waveforms. Secondly, tensile-shear strength of the spot-welded joint was employed as evaluating target of weld quality. Through correlation analysis between every two parameters of characteristic vector, five characteristic parameters were reasonably selected to found a mapping model of weld quality estimation. At last, the model was realized by means of the algorithms of Radial Basic Function neural network and sample matrixes. The results showed validations by a satisfaction in evaluating weld quality of mild steel joint on-line in spot welding process.

  2. Study on DO and pH as on-line control parameters in A2 N-IC-SBR process%pH和DO作为A2 N-IC-SBR工艺实时控制参数

    Institute of Scientific and Technical Information of China (English)

    史静; 吕锡武; 许正文; 张斯路; 方梦媛

    2014-01-01

    From the phosphorus removal sludge and nitrogen removal sludge cultivation period to the steady operation period of A2 N-IC-SBR(anaerobic/anoxic/nitration-induced crystallization-sequencing batch reactor,A2 N-IC-SBR)process,the relationships between pH/DO and nutrient concentrations were investigated systematically,including sludge cultivation stage,A2 N process operation stage and A2 N-IC process operation stage.The results indicate that in the anaerobic stage,pH profile is compli-cated.It is related to the influent C/P ratio,enrichment of denitrifying polyphosphate accumulating organisms and phosphorus accumulating organisms.With different sludge characteristics and influent wastewater compositions,it shows different variations.During the IC(induced crystallization)stage, the dosage modes and mixture approaches affect the pH variations.SP has no obvious correlation with pH.Under the nitrification stage,the feature points for nitrification ending are apparent.The maxi-mum value of d(DO)/dt and the point of d(pH)/dt from negative to positive can both be the feature points for indicating the end of nitrification.In the aerobic phosphorus removal stage,the inflexion point of pH,the sharp rise point of DO and the end of phosphorus removal appear at the same time. An inflexion point of pH is observed when the denitrifying phosphorus removal is finished.%试验从硝化污泥和聚磷污泥的培养开始至A2 N-IC-SBR工艺稳定运行结束,系统地记录了污泥驯化培养阶段、A2 N工艺运行阶段、A2 N-IC工艺运行阶段中pH和DO 的变化与氮磷浓度的关系。结果表明:厌氧阶段pH的变化比较复杂,与进水碳磷比、反硝化聚磷菌和好氧聚磷菌的富集程度等因素有关,不同的进水水质与污泥有不同的变化规律;诱导结晶阶段pH的变化受到钙盐投药方式以及混合方式的影响,pH与SP浓度的变化并不存在明显的相关性;硝化反应中硝化作用完成的特征点较明显

  3. Evaluation of SRAT Sampling Data in Support of a Six Sigma Yellow Belt Process Improvement Project

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Thomas B.

    2005-06-01

    As part of the Six Sigma continuous improvement initiatives at the Defense Waste Processing Facility (DWPF), a Yellow Belt team was formed to evaluate the frequency and types of samples required for the Sludge Receipt and Adjustment Tank (SRAT) receipt in the DWPF. The team asked, via a technical task request, that the Statistical Consulting Section (SCS), in concert with the Immobilization Technology Section (ITS) (both groups within the Savannah River National Laboratory (SRNL)), conduct a statistical review of recent SRAT receipt results to determine if there is enough consistency in these measurements to allow for less frequent sampling. As part of this review process, key decisions made by DWPF Process Engineering that are based upon the SRAT sample measurements are outlined in this report. For a reduction in SRAT sampling to be viable, these decisions must not be overly sensitive to the additional variation that will be introduced as a result of such a reduction. Measurements from samples of SRAT receipt batches 314 through 323 were reviewed as part of this investigation into the frequency of SRAT sampling. The associated acid calculations for these batches were also studied as part of this effort. The results from this investigation showed no indication of a statistically significant relationship between the tank solids and the acid additions for these batches. One would expect that as the tank solids increase there would be a corresponding increase in acid requirements. There was, however, an indication that the predicted reduction/oxidation (REDOX) ratio (the ratio of Fe{sup 2+} to the total Fe in the glass product) that was targeted by the acid calculations based on the SRAT receipt samples for these batches was on average 0.0253 larger than the predicted REDOX based upon Slurry Mix Evaporator (SME) measurements. This is a statistically significant difference (at the 5% significance level), and the study also suggested that the difference was due to

  4. Assessment of toxic metals in raw and processed milk samples using electrothermal atomic absorption spectrophotometer.

    Science.gov (United States)

    Kazi, Tasneem Gul; Jalbani, Nusrat; Baig, Jameel Ahmed; Kandhro, Ghulam Abbas; Afridi, Hassan Imran; Arain, Mohammad Balal; Jamali, Mohammad Khan; Shah, Abdul Qadir

    2009-09-01

    Milk and dairy products have been recognized all over the world for their beneficial influence on human health. The levels of toxic metals (TMs) are an important component of safety and quality of milk. A simple and efficient microwave assisted extraction (MAE) method has been developed for the determination of TMs (Al, Cd, Ni and Pb), in raw and processed milk samples. A Plackett-Burman experimental design and 2(3)+star central composite design, were applied in order to determine the optimum conditions for MAE. Concentrations of TMs were measured by electrothermal atomic absorption spectrometry. The accuracy of the optimized procedure was evaluated by standard addition method and conventional wet acid digestion method (CDM), for comparative purpose. No significant differences were observed (P>0.05), when comparing the values obtained by the proposed MAE method and CDM (paired t-test). The average relative standard deviation of the MAE method varied between 4.3% and 7.6% based on analyte (n=6). The proposed method was successfully applied for the determination of understudy TMs in milk samples. The results of raw and processed milk indicated that environmental conditions and manufacturing processes play a key role in the distribution of toxic metals in raw and processed milk.

  5. 近红外在线检测技术在人参提取物生产中的应用%Application of Near-infrared Spectroscopy On-line Detection to Production Process of Ginseng Extract

    Institute of Scientific and Technical Information of China (English)

    张瑞; 王英平; 刘宏群; 许世泉; 闫梅霞; 赵景辉

    2012-01-01

    This experiment aims to use near-infrared spectroscopy to generate the spectrum of Chinese ginseng samples. The total ginseno-sides contents and near-infrared spectroscopy figure were determined in raw materials of ginseng and SS8 extract solutions. Raw materials of ginseng came from 93 different places, and born in different years. Using partial least squares (PLS), the methematical models were developed to correlate near infrared spectra and total ginsenosides contents. Method of cross-validation was adopted to evaluate these models, the results showed: Trie correlation coefficients of model were all above 0.95, the root mean square error of cross-validation (RMSEC V) values were 0.0716 and 0.032 7, ratio of deviation to performances (RPD) of model finally developed were 2.83 and 3.97 respectively. The model achieved the best prediction performance, and there is no significant difference between predictive contents and chemical reference values. The result indicates that NIR spectroscopy could be used in practice to fast determine the total ginsenoside contents of powder and extract solutions.%采用比色法和近红外漫反射、液体透射在线检测技术,分别测定93个不同产地、不同年生人参原材料固体样品和558个人参提取液样品的总皂苷含量和近红外光谱,结合偏最小二乘回归法,建立样品总皂苷含量与近红外光谱之间的数学模型.采用内部交叉检验对模型进行评价.评价结果显示:内部交叉检验的决定系数R2> 0.95,交义检验均方差(RMSECV)值分别为0.071 6和0.032 7,相对分析误差(RPD)分别为2.83和3.97.模型评价数据均有较好的表现,原材料、提取液检验样品近红外测定结果与化学参考值之间无显著性差异,近红外检测技术可以应用于人参原材料固体样品和人参提取液样品中总皂苷含量的快速测定.

  6. On-line and Mobil Learning Activities

    Science.gov (United States)

    Ackerman, S. A.; Whittaker, T. M.; Jasmin, T.; Mooney, M. E.

    2012-12-01

    Introductory college-level science courses for non-majors are critical gateways to imparting not only discipline-specific information, but also the basics of the scientific method and how science influences society. They are also indispensable for student success to degree. On-line, web-based homework (whether on computers or mobile devices) is a rapidly growing use of the Internet and is becoming a major component of instruction in science, replacing delayed feedback from a few major exams. Web delivery and grading of traditional textbook-type questions is equally effective as having students write them out for hand grading, as measured by student performance on conceptual and problem solving exams. During this presentation we will demonstrate some of the interactive on-line activities used to teach concepts and how scientists approach problem solving, and how these activities have impacted student learning. Evaluation of the activities, including formative and summative, will be discussed and provide evidence that these interactive activities significantly enhance understanding of introductory meteorological concepts in a college-level science course. More advanced interactive activities are also used in our courses for department majors, some of these will be discussed and demonstrated. Bring your mobile devices to play along! Here is an example on teaching contouring: http://profhorn.aos.wisc.edu/wxwise/contour/index.html

  7. Adaptive Nonlinear Model Predictive Control Using an On-line Support Vector Regression Updating Strategy

    Institute of Scientific and Technical Information of China (English)

    Ping Wang; Chaohe Yang; Xuemin Tian; Dexian Huang

    2014-01-01

    The performance of data-driven models relies heavily on the amount and quality of training samples, so it might deteriorate significantly in the regions where samples are scarce. The objective of this paper is to develop an on-line SVR model updating strategy to track the change in the process characteristics efficiently with affordable computational burden. This is achieved by adding a new sample that violates the Karush-Kuhn-Tucker condi-tions of the existing SVR model and by deleting the old sample that has the maximum distance with respect to the newly added sample in feature space. The benefits offered by such an updating strategy are exploited to develop an adaptive model-based control scheme, where model updating and control task perform alternately. The effectiveness of the adaptive controller is demonstrated by simulation study on a continuous stirred tank reactor. The results reveal that the adaptive MPC scheme outperforms its non-adaptive counterpart for large-magnitude set point changes and variations in process parameters.

  8. On Line Spectrophotometric Measurement of Uranium and Nitrate in H Canyon

    Energy Technology Data Exchange (ETDEWEB)

    Lascola, R.J.

    2002-10-15

    This report describes the on-line instrumentation developed by the Analytical Development Section of Savannah River Technology Center in support of Highly Enriched Uranium Blend Down processing in H Canyon.

  9. A multisyringe flow-through sequential extraction system for on-line monitoring of orthophosphate in soils and sediments

    DEFF Research Database (Denmark)

    Buanuam, Janya; Miró, Manuel; Hansen, Elo Harald

    2007-01-01

    A fully automated flow-through microcolumn fractionation system with on-line post-extraction derivatization is proposed for monitoring of orthophosphate in solid samples of environmental relevance. The system integrates dynamic sequential extraction using 1.0 mol l-1 NH4Cl, 0.1 mol l-1 NaOH and 0.......5 mol l-1 HCl as extractants according to the Hietjles-Lijklema (HL) scheme for fractionation of phosphorus associated with different geological phases, and on-line processing of the extracts via the Molybdenum Blue (MB) reaction by exploiting multisyringe flow injection as the interface between...... the solid containing microcolumn and the flow-through detector. The proposed flow assembly, capitalizing on the features of the multicommutation concept, implies several advantages as compared to fractionation analysis in the batch mode in terms of saving of extractants and MB reagents, shortening...

  10. Improvement of microtome cutting process of carbon nanotube composite sample preparation for TEM analysis

    Science.gov (United States)

    Trayner, Sarah

    As research progresses towards nanoscale materials, there has become a need for a more efficient and effective way to obtain ultra-thin samples for imaging under transmission electron microscope (TEM) for atomic resolution analysis. There are various methods used to obtain thin samples (epoxy composites, are of poor quality due to the sample cutting difficulties. Such poor quality samples are characterized by uneven sample thicknesses, objective overlapping, overall darkness due to large thickness, and defects such as cutting scratches. This research is a continuous effort to study and improve the ultra-microtome cutting technique to provide an effective and reliable approach of obtaining an ultra-thin (25-50 nm) cross section of a CNT/polymer composite for high resolution TEM analysis. Improvements were achieved by studying the relationships between the chosen cutting parameters, sample characteristics and TEM image quality. From this information, a cutting protocol was established so that ultra-thin sample slices can be achieved by different microtome operators for high resolution TEM analysis. In addition, a custom tool was created to aid in the sample collection process. In this research, three composite samples were studied for both microtome cutting and TEM analysis: 1) Unidirectional (UD) IM7/BMI composite; 2) Single-layer CNT buckypaper (BP)/epoxy nanocomposite; 3) 3-layer CNT BP/BMI nanocomposite. The resultant TEM images revealed a clear microstructure consisting of amorphous resin and graphite crystalline packing. UD IM7/BMI composite TEM results did not reveal an interfacial region resulting in a need for even thinner sliced cross sections. TEM results for the single-layer CNT BP/epoxy nanocomposite revealed the alignment direction of the nanotubes and numerous stacks of CNT bundles. In addition, there was visible flattening of CNT packing into dumbbell shapes similar to results obtain by Alan Windle. TEM results for the 3-layer CNT BP/BMI nanocomposite

  11. Using NDVI and guided sampling to develop yield prediction maps of processing tomato crop

    Energy Technology Data Exchange (ETDEWEB)

    Fortes, A.; Henar Prieto, M. del; García-Martín, A.; Córdoba, A.; Martínez, L.; Campillo, C.

    2015-07-01

    The use of yield prediction maps is an important tool for the delineation of within-field management zones. Vegetation indices based on crop reflectance are of potential use in the attainment of this objective. There are different types of vegetation indices based on crop reflectance, the most commonly used of which is the NDVI (normalized difference vegetation index). NDVI values are reported to have good correlation with several vegetation parameters including the ability to predict yield. The field research was conducted in two commercial farms of processing tomato crop, Cantillana and Enviciados. An NDVI prediction map developed through ordinary kriging technique was used for guided sampling of processing tomato yield. Yield was studied and related with NDVI, and finally a prediction map of crop yield for the entire plot was generated using two geostatistical methodologies (ordinary and regression kriging). Finally, a comparison was made between the yield obtained at validation points and the yield values according to the prediction maps. The most precise yield maps were obtained with the regression kriging methodology with RRMSE values of 14% and 17% in Cantillana and Enviciados, respectively, using the NDVI as predictor. The coefficient of correlation between NDVI and yield was correlated in the point samples taken in the two locations, with values of 0.71 and 0.67 in Cantillana and Enviciados, respectively. The results suggest that the use of a massive sampling parameter such as NDVI is a good indicator of the distribution of within-field yield variation. (Author)

  12. Robust Control Methods for On-Line Statistical Learning

    Directory of Open Access Journals (Sweden)

    Capobianco Enrico

    2001-01-01

    Full Text Available The issue of controlling that data processing in an experiment results not affected by the presence of outliers is relevant for statistical control and learning studies. Learning schemes should thus be tested for their capacity of handling outliers in the observed training set so to achieve reliable estimates with respect to the crucial bias and variance aspects. We describe possible ways of endowing neural networks with statistically robust properties by defining feasible error criteria. It is convenient to cast neural nets in state space representations and apply both Kalman filter and stochastic approximation procedures in order to suggest statistically robustified solutions for on-line learning.

  13. Data Validation Package - April and July 2015 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site

    Energy Technology Data Exchange (ETDEWEB)

    Linard, Joshua [Dept. of Energy (DOE), Washington, DC (United States). Office of Legacy Management; Campbell, Sam [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-02-01

    This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.

  14. The impact of fecal sample processing on prevalence estimates for antibiotic-resistant Escherichia coli.

    Science.gov (United States)

    Omulo, Sylvia; Lofgren, Eric T; Mugoh, Maina; Alando, Moshe; Obiya, Joshua; Kipyegon, Korir; Kikwai, Gilbert; Gumbi, Wilson; Kariuki, Samuel; Call, Douglas R

    2017-05-01

    Investigators often rely on studies of Escherichia coli to characterize the burden of antibiotic resistance in a clinical or community setting. To determine if prevalence estimates for antibiotic resistance are sensitive to sample handling and interpretive criteria, we collected presumptive E. coli isolates (24 or 95 per stool sample) from a community in an urban informal settlement in Kenya. Isolates were tested for susceptibility to nine antibiotics using agar breakpoint assays and results were analyzed using generalized linear mixed models. We observed a 0.1). Prevalence estimates did not differ for five distinct E. coli colony morphologies on MacConkey agar plates (P>0.2). Successive re-plating of samples for up to five consecutive days had little to no impact on prevalence estimates. Finally, culturing E. coli under different conditions (with 5% CO2 or micro-aerobic) did not affect estimates of prevalence. For the conditions tested in these experiments, minor modifications in sample processing protocols are unlikely to bias estimates of the prevalence of antibiotic-resistance for fecal E. coli.

  15. Genetic effects on information processing speed are moderated by age--converging results from three samples.

    Science.gov (United States)

    Ising, M; Mather, K A; Zimmermann, P; Brückl, T; Höhne, N; Heck, A; Schenk, L A; Rujescu, D; Armstrong, N J; Sachdev, P S; Reppermund, S

    2014-06-01

    Information processing is a cognitive trait forming the basis of complex abilities like executive function. The Trail Making Test (TMT) is a well-established test of information processing with moderate to high heritability. Age of the individual also plays an important role. A number of genetic association studies with the TMT have been performed, which, however, did not consider age as a moderating factor. We report the results of genome-wide association studies (GWASs) on age-independent and age-dependent TMT performance in two population-representative community samples (Munich Antidepressant Response Signature, MARS: N1 = 540; Ludwig Maximilians University, LMU: N2 = 350). Age-dependent genome-wide findings were then evaluated in a third sample of healthy elderly subjects (Sydney Memory and Ageing Study, Sydney MAS: N3 = 448). While a meta-analysis on the GWAS findings did not reveal age-independent TMT associations withstanding correction for multiple testing, we found a genome-wide significant age-moderated effect between variants in the DSG1 gene region and TMT-A performance predominantly reflecting visual processing speed (rs2199301, P(meta-analysis) = 1.3 × 10(-7)). The direction of the interaction suggests for the minor allele a beneficial effect in younger adults turning into a detrimental effect in older adults. The detrimental effect of the missense single nucleotide polymorphism rs1426310 within the same DSG1 gene region could be replicated in Sydney MAS participants aged 70-79, but not in those aged 80 years and older, presumably a result of survivor bias. Our findings demonstrate opposing effects of DSG1 variants on information processing speed depending on age, which might be related to the complex processes that DSG1 is involved with, including cell adhesion and apoptosis.

  16. Microstructural and magnetic analysis of a superconducting foam and comparison with IG-processed bulk samples

    Science.gov (United States)

    Koblischka-Veneva, A.; Koblischka, M. R.; Ide, N.; Inoue, K.; Muralidhar, M.; Hauet, T.; Murakami, M.

    2016-03-01

    YBa2Cu3Oy (YBCO) foam samples show an open, porous foam structure, which may have benefits for many applications of high-T c superconductors. As the basic material of these foams is a pseudo-single crystalline material with the directional growth initiated by a seed crystal similar to standard melt-textured samples, the achieved texture of the YBCO is a very important parameter. We analyzed the local texture and grain orientation of the individual struts forming the foam by means of atomic force microscopy and electron backscatter diffraction (EBSD). Furthermore, the magnetic properties of a foam strut are evaluated by means of SQUID measurements, from which the flux pinning forces were determined. A scaling of the pinning forces in the temperature range between 60 K and 85 K was performed. These data and the details of the microstructure are compared to IG-processed, bulk material.

  17. Removal of Pb ion from water samples using red mud (bauxite ore processing waste

    Directory of Open Access Journals (Sweden)

    Ghorbani A.

    2014-07-01

    Full Text Available This work presented the use of red mud (bauxite ore processing waste in removal of lead ions in water samples. For this 0.1 g of red mud has been used as adsorbent which suspended in 10 ml of lead solution with the concentration of 50 mg l-1 for about 1 h. After that the lead concentration in the samples taken from the red mud treated lead solution measured with atomic absorption spectroscopy (AAS. The effect of some parameter which is important in adsorption of lead on red mud such as suitable adsorbent dosage, pH and contact time of solution and adsorbent was investigated. The result shows that red mud as solid waste and low-cost adsorbent can be successfully used for the removal of lead ion from aqueous solution.

  18. Chemical process to separate iron oxides particles in pottery sample for EPR dating

    Science.gov (United States)

    Watanabe, S.; Farias, T. M. B.; Gennari, R. F.; Ferraz, G. M.; Kunzli, R.; Chubaci, J. F. D.

    2008-12-01

    Ancient potteries usually are made of the local clay material, which contains relatively high concentration of iron. The powdered samples are usually quite black, due to magnetite, and, although they can be used for thermoluminescene (TL) dating, it is easiest to obtain better TL reading when clearest natural or pre-treated sample is used. For electron paramagnetic resonance (EPR) measurements, the huge signal due to iron spin-spin interaction, promotes an intense interference overlapping any other signal in this range. Sample dating is obtained by dividing the radiation dose, determined by the concentration of paramagnetic species generated by irradiation, by the natural dose so as a consequence, EPR dating cannot be used, since iron signal do not depend on radiation dose. In some cases, the density separation method using hydrated solution of sodium polytungstate [Na 6(H 2W 12O 40)·H 2O] becomes useful. However, the sodium polytungstate is very expensive in Brazil; hence an alternative method for eliminating this interference is proposed. A chemical process to eliminate about 90% of magnetite was developed. A sample of powdered ancient pottery was treated in a mixture (3:1:1) of HCl, HNO 3 and H 2O 2 for 4 h. After that, it was washed several times in distilled water to remove all acid matrixes. The original black sample becomes somewhat clearer. The resulting material was analyzed by plasma mass spectrometry (ICP-MS), with the result that the iron content is reduced by a factor of about 9. In EPR measurements a non-treated natural ceramic sample shows a broad spin-spin interaction signal, the chemically treated sample presents a narrow signal in g = 2.00 region, possibly due to a radical of (SiO 3) 3-, mixed with signal of remaining iron [M. Ikeya, New Applications of Electron Spin Resonance, World Scientific, Singapore, 1993, p. 285]. This signal increases in intensity under γ-irradiation. However, still due to iron influence, the additive method yielded too

  19. L. monocytogenes in a cheese processing facility: Learning from contamination scenarios over three years of sampling.

    Science.gov (United States)

    Rückerl, I; Muhterem-Uyar, M; Muri-Klinger, S; Wagner, K-H; Wagner, M; Stessl, B

    2014-10-17

    The aim of this study was to analyze the changing patterns of Listeria monocytogenes contamination in a cheese processing facility manufacturing a wide range of ready-to-eat products. Characterization of L. monocytogenes isolates included genotyping by pulsed-field gel electrophoresis (PFGE) and multi-locus sequence typing (MLST). Disinfectant-susceptibility tests and the assessment of L. monocytogenes survival in fresh cheese were also conducted. During the sampling period between 2010 and 2013, a total of 1284 environmental samples were investigated. Overall occurrence rates of Listeria spp. and L. monocytogenes were 21.9% and 19.5%, respectively. Identical L. monocytogenes genotypes were found in the food processing environment (FPE), raw materials and in products. Interventions after the sampling events changed contamination scenarios substantially. The high diversity of globally, widely distributed L. monocytogenes genotypes was reduced by identifying the major sources of contamination. Although susceptible to a broad range of disinfectants and cleaners, one dominant L. monocytogenes sequence type (ST) 5 could not be eradicated from drains and floors. Significantly, intense humidity and steam could be observed in all rooms and water residues were visible on floors due to increased cleaning strategies. This could explain the high L. monocytogenes contamination of the FPE (drains, shoes and floors) throughout the study (15.8%). The outcome of a challenge experiment in fresh cheese showed that L. monocytogenes could survive after 14days of storage at insufficient cooling temperatures (8 and 16°C). All efforts to reduce L. monocytogenes environmental contamination eventually led to a transition from dynamic to stable contamination scenarios. Consequently, implementation of systematic environmental monitoring via in-house systems should either aim for total avoidance of FPE colonization, or emphasize a first reduction of L. monocytogenes to sites where

  20. Aprender a innovar: una experiencia on line

    Directory of Open Access Journals (Sweden)

    Joaquín MORENO MARCHAL

    2014-11-01

    Full Text Available La creatividad y la innovación se han convertido en recursos clave en la denominada sociedad del conocimiento, que bien podría ser también llamada sociedad de la innovación. Pero innovar es una actividad compleja, que integra la aplicación de múltiples capacidades, el pensamiento divergente y convergente, la gestión de equipos humanos, la comunicación. Ahora bien, a innovar se puede, y se debe, aprender. Aprender a innovar es un reto y también una obligación para el conjunto del sistema educativo en todos sus niveles. Partiendo de estas consideraciones este trabajo expone una experiencia de aprendizaje de la creatividad y de la innovación a través de un curso totalmente on line basado en la plataforma MOODLE, en el marco del Programa de Formación Permanente de la Universidad de Cádiz. Se presenta un modelo del proceso de innovación, denominado CREALAB, de elaboración propia. Este modelo se ha utilizado como base del proceso de aprendizaje de la creatividad y de la innovación y en el diseño del curso, está organizado en torno a actividades y tiene un carácter iterativo y realimentado. Se presentan además el conjunto del diseño metodológico y los resultados obtenidos en las dos ediciones celebradas hasta el momento. El diseño del curso totalmente on line y los resultados alcanzados permiten estimar un alto potencial de aplicación, tanto a nivel personal como a nivel organizacional.

  1. Development of an on-line state estimator for fed-batch filamentous fungal fermentations

    DEFF Research Database (Denmark)

    Mears, Lisa; Stocks, Stuart M.; Albæk, Mads O.

    Bioprocesses can be challenging to model due to complex and non-linear process dynamics [1]. In addition there is a lack of robust, on-line sensors for key parameters of interest in the field, such as substrate, product and biomass concentration [2]. These factors lead to limitations in the ability...... to monitor and control bioprocess systems. There is therefore an interest in state estimation, in order to model these key process states based on available on-line measurements [1]. This work discusses the application of a first principle model to pilot scale filamentous fungal fermentation systems operated...... pressure [4], [5]. This stoichiometric-based coupled process model is successfully applied on-line as a state estimator in order to predict the biomass and product concentration, from robust, available on-line measurements. Such state estimators will be valuable as part of control strategy development...

  2. Synthetic Aperture Sonar Processing with MMSE Estimation of Image Sample Values

    Science.gov (United States)

    2016-12-01

    UNCLASSIFIED/UNLIMITED 13. SUPPLEMENTARY NOTES 14. ABSTRACT MMSE (minimum mean -square error) target sample estimation using non-orthogonal basis...aspects, without a significant increase in SNR. The MMSE process creates images with new features that can be applied to image-based compensation of...orthogonal, they can still be used in a minimum  mean ‐square error (MMSE)  estimator that models the object echo as a weighted sum of the multi‐aspect basis

  3. On line high dose static position monitoring by ionization chamber detector for industrial gamma irradiators.

    Science.gov (United States)

    Rodrigues, Ary A; Vieira, Jose M; Hamada, Margarida M

    2010-01-01

    A 1 cm(3) cylindrical ionization chamber was developed to measure high doses on line during the sample irradiation in static position, in a (60)Co industrial plant. The developed ionization chamber showed to be suitable for use as a dosimeter on line. A good linearity of the detector was found between the dose and the accumulated charge, independently of the different dose rates caused by absorbing materials.

  4. On line high dose static position monitoring by ionization chamber detector for industrial gamma irradiators

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Ary A. [Universidade Estadual de Londrina-Depto de Fisica, Rodovia Celso Garcia Cid, km 38, 086051-990 Londrina (Brazil); Vieira, Jose M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN-SP, Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-900 Sao Paulo (Brazil); Hamada, Margarida M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN-SP, Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-900 Sao Paulo (Brazil)], E-mail: mmhamada@ipen.br

    2010-04-15

    A 1 cm{sup 3} cylindrical ionization chamber was developed to measure high doses on line during the sample irradiation in static position, in a {sup 60}Co industrial plant. The developed ionization chamber showed to be suitable for use as a dosimeter on line. A good linearity of the detector was found between the dose and the accumulated charge, independently of the different dose rates caused by absorbing materials.

  5. A Refreshable, On-line Cache for HST Data Retrieval

    Science.gov (United States)

    Fraquelli, Dorothy A.; Ellis, Tracy A.; Ridgaway, Michael; DPAS Team

    2016-01-01

    We discuss upgrades to the HST Data Processing System, with an emphasis on the changes Hubble Space Telescope (HST) Archive users will experience. In particular, data are now held on-line (in a cache) removing the need to reprocess the data every time they are requested from the Archive. OTFR (on the fly reprocessing) has been replaced by a reprocessing system, which runs in the background. Data in the cache are automatically placed in the reprocessing queue when updated calibration reference files are received or when an improved calibration algorithm is installed. Data in the on-line cache are expected to be the most up to date version. These changes were phased in throughout 2015 for all active instruments.The on-line cache was populated instrument by instrument over the course of 2015. As data were placed in the cache, the flag that triggers OTFR was reset so that OTFR no longer runs on these data. "Hybrid" requests to the Archive are handled transparently, with data not yet in the cache provided via OTFR and the remaining data provided from the cache. Users do not need to make separate requests.Users of the MAST Portal will be able to download data from the cache immediately. For data not in the cache, the Portal will send the user to the standard "Retrieval Options Page," allowing the user to direct the Archive to process and deliver the data.The classic MAST Search and Retrieval interface has the same look and feel as previously. Minor changes, unrelated to the cache, have been made to the format of the Retrieval Options Page.

  6. A versatile apparatus for on-line emission channeling experiments

    CERN Document Server

    da Silva, Manuel Ribeiro; Correia, João Guilherme; Amorim, Lígia Marina; Pereira, Lino Miguel da Costa

    2013-01-01

    The concept and functionality of an apparatus dedicated to emission channeling experiments using short-lived isotopes on-line at ISOLDE/CERN is described. The setup is assembled in two functional blocks - (a) base stand including beam collimation, implantation and measurement chamber, cryogenic extension, and vacuum control system and - (b) Panmure goniometer extension including maneuvering cradle and sample heating furnace. This setup allows for in situ implantation and sample analysis in the as-implanted state and upon cooling down to 50 K and during annealing up to 1200 K. The functionality of the setup will be illustrated with the example of establishing the lattice location of $^{56}$Mn probes implanted into GaAs.

  7. Comportamento do Consumidor On-line: a perspectiva da teoria do fluxoOn-line Consumer Behavior: the flow theory perspectiveComportamiento del consumidor On-line: la perspectiva de la teoría del flujo

    Directory of Open Access Journals (Sweden)

    FARIAS, Salomão Alencar de

    2008-03-01

    is its applicableness for achieving consumer satisfaction in the purchase by the Internet. It was used a descriptive methodology with the application of a survey to a sample of 237 electronic retail consumers. Collected data was analyzed by means of multivariate statistical techniques and results indicated that the on-line environment and the telepresence precede the flow, that in turn is associated to the exploratory behavior, positive effect of the navigation process, purchase and satisfaction with the purchase process.RESUMENEste artículo investiga el comportamiento del consumidor por Internet con base en el flujo, definido como la sensación holística que las personas sienten cuando realizan una actividad totalmente involucradas (CSIKSZENTMIHALYI, 1975. Esta teoría se utiliza para comprender mejor la conducta de compra por medio de la Internet, aunque este concepto todavía no esté muy claro en la literatura sobre el comportamiento del consumidor, puesto que no existe un consenso con respecto a los factores que preceden, caracterizan o son consecuencia del estado de flujo. De este modo, esta investigación buscó identificar los constructos relacionados con el estado de flujo que deben formar parte del esquema de comportamiento de la compra on line, además de indicar cuál es su aplicabilidad para obtención de la satisfacción del consumidor en la compra por la red. Fue utilizada una metodología del carácter descriptivo mediante aplicación de survey a una muestra de 237 consumidores de venta electrónica al por menor. Los datos recogidos se analizaron por medio de técnicas estadísticas multivariadas. Los resultados indicaron que el ambiente on line y la telepresencia preceden al flujo, que a su vez está asociado a la conducta exploratoria, un efecto positivo del proceso de navegación, compra y satisfacción con el proceso de compra.

  8. An efficient sampling algorithm for uncertain abnormal data detection in biomedical image processing and disease prediction.

    Science.gov (United States)

    Liu, Fei; Zhang, Xi; Jia, Yan

    2015-01-01

    In this paper, we propose a computer information processing algorithm that can be used for biomedical image processing and disease prediction. A biomedical image is considered a data object in a multi-dimensional space. Each dimension is a feature that can be used for disease diagnosis. We introduce a new concept of the top (k1,k2) outlier. It can be used to detect abnormal data objects in the multi-dimensional space. This technique focuses on uncertain space, where each data object has several possible instances with distinct probabilities. We design an efficient sampling algorithm for the top (k1,k2) outlier in uncertain space. Some improvement techniques are used for acceleration. Experiments show our methods' high accuracy and high efficiency.

  9. Sampling methods for the quasistationary regime of epidemic processes on regular and complex networks

    CERN Document Server

    Sander, Renan S; Ferreira, Silvio C

    2016-01-01

    A major hurdle in the simulation of the steady state of epidemic processes is that the system will unavoidably visit an absorbing, disease-free state at sufficiently long times due to the finite size of the networks where epidemics evolves. In the present work, we compare different quasistationary (QS) simulation methods where the absorbing states are suitably handled and the thermodynamical limit of the original dynamics can be achieved. We analyzed the standard QS (SQS) method, where the sampling is constrained to active configurations, the reflecting boundary condition (RBC), where the dynamics returns to the pre-absorbing configuration, and hub reactivation (HR), where the most connected vertices of the network is reactivated after a visit to an absorbing state. We applied the methods to the contact process (CP) and susceptible-infected-susceptible (SIS) models on regular and scale-free networks. The investigated methods yield the same epidemic threshold for both models. For CP, that undergoes a standard ...

  10. Solar Ion Processing of Itokawa Grains: Reconciling Model Predictions with Sample Observations

    Science.gov (United States)

    Christoffersen, Roy; Keller, L. P.

    2014-01-01

    Analytical TEM observations of Itokawa grains reported to date show complex solar wind ion processing effects in the outer 30-100 nm of pyroxene and olivine grains. The effects include loss of long-range structural order, formation of isolated interval cavities or "bubbles", and other nanoscale compositional/microstructural variations. None of the effects so far described have, however, included complete ion-induced amorphization. To link the array of observed relationships to grain surface exposure times, we have adapted our previous numerical model for progressive solar ion processing effects in lunar regolith grains to the Itokawa samples. The model uses SRIM ion collision damage and implantation calculations within a framework of a constant-deposited-energy model for amorphization. Inputs include experimentally-measured amorphization fluences, a Pi steradian variable ion incidence geometry required for a rotating asteroid, and a numerical flux-versus-velocity solar wind spectrum.

  11. On-line Determination of Hydrochloric Acid in Process Effluent ...

    African Journals Online (AJOL)

    Prof Van Staden

    The results obtained with the proposed system were compared with the results obtained from ..... The null hypothesis which assumes that the quantities from two different ... 14 R.H. Taylor, J. Ruzicka and G.D. Christian, Talanta, 1992, 39, 285.

  12. PROFILES AND PREFERENCES OF ON-LINE MILLENIAL SHOPPERS IN BULGARIA

    Directory of Open Access Journals (Sweden)

    Patricia R. Loubeau

    2014-05-01

    Full Text Available This research seeks to develop a better understanding of the factors affecting on-line purchasing behavior among Generation Y (Gen Y consumers in Bulgaria. Also called millenials and born between the mid-1970s and late 1990s, this generation is especially active on-line and will be a dominant influence shaping e-commerce. An empirical study was conducted based on a written survey of a sample consisting of 367 high school and university students in Bulgaria. The most important reason why Bulgarian young people shop on-line is the pursuit of unique products not locally available, followed by convenience and better pricing, and their favorite category of internet purchases is “Apparel and Accessories.” Bulgarian millennials are using the internet to shop for trendy fashion and to obtain a variety of brands that are unavailable locally. Like other regions of the world, concern about financial transactions security is a major barrier limiting the willingness to shop on-line in Bulgaria. Unlike other markets where on-line music purchases are growing, high levels of digital piracy in Bulgaria strongly discourage Bulgarian students from purchasing music on-line. One limitation of this study arises because of its reliance on a convenience sample of students from medium sized cities in Southern Bulgaria. Further research employing stratified random sampling across Bulgaria is needed to assess whether the findings are broadly generalizable for the Gen Y population.

  13. Exact run length distribution of the double sampling x-bar chart with estimated process parameters

    Directory of Open Access Journals (Sweden)

    Teoh, W. L.

    2016-05-01

    Full Text Available Since the run length distribution is generally highly skewed, a significant concern about focusing too much on the average run length (ARL criterion is that we may miss some crucial information about a control chart’s performance. Thus it is important to investigate the entire run length distribution of a control chart for an in-depth understanding before implementing the chart in process monitoring. In this paper, the percentiles of the run length distribution for the double sampling (DS X chart with estimated process parameters are computed. Knowledge of the percentiles of the run length distribution provides a more comprehensive understanding of the expected behaviour of the run length. This additional information includes the early false alarm, the skewness of the run length distribution, and the median run length (MRL. A comparison of the run length distribution between the optimal ARL-based and MRL-based DS X chart with estimated process parameters is presented in this paper. Examples of applications are given to aid practitioners to select the best design scheme of the DS X chart with estimated process parameters, based on their specific purpose.

  14. Signal and Image Processing of Optical Coherence Tomography at 1310 nm Wavelength for Non Biological Samples

    Directory of Open Access Journals (Sweden)

    Yogesh Rao

    2015-04-01

    Full Text Available OCT is a recently developed optical interferometric technique for non-invasive diagnostic medical imaging in vivo; the most sensitive optical imaging modality.OCT finds its application in ophthalmology, blood flow estimation and cancer diagnosis along with many non biomedical applications. The main advantage of OCT is its high resolution which is in µm range and depth of penetration in mm range. Unlike other techniques like X rays and CT scan, OCT does not comprise any x ray source and therefore no radiations are involved. This research work discusses the basics of spectral domain OCT (SD-OCT, experimental setup, data acquisition and signal processing involved in OCT systems. Simulation of OCT involving modelling and signal processing, carried out on Lab VIEW platform has been discussed. Using the experimental setup, some of the non biomedical samples have been scanned. The signal processing and image processing of the scanned data was carried out in MATLAB and Lab VIEW, some of the results thus obtained have been discussed in the end.

  15. Efficiency of advanced oxidation processes in lowering bisphenol A toxicity and oestrogenic activity in aqueous samples.

    Science.gov (United States)

    Plahuta, Maja; Tišler, Tatjana; Toman, Mihael Jožef; Pintar, Albin

    2014-03-01

    Bisphenol A (BPA) is a well-known endocrine disruptor with adverse oestrogen-like effects eliciting adverse effects in humans and wildlife. For this reason it is necessary to set up an efficient removal of BPA from wastewaters, before they are discharged into surface waters. The aim of this study was to compare the efficiency of BPA removal from aqueous samples with photolytic, photocatalytic, and UV/H₂O₂ oxidation. BPA solutions were illuminated with different bulbs (halogen; 17 W UV, 254 nm; and 150 W UV, 365 nm) with or without the TiO₂ P-25 catalyst or H₂O₂ (to accelerate degradation). Acute toxicity and oestrogenic activity of treated samples were determined using luminescent bacteria (Vibrio fischeri), water fleas (Daphnia magna), zebrafish embryos (Danio rerio), and Yeast Estrogen Screen (YES) assay with genetically modified yeast Saccharomyces cerevisiae. The results confirmed that BPA is toxic and oestrogenically active. Chemical analysis showed a reduction of BPA levels after photolytic treatment and 100 % conversion of BPA by photocatalytic and UV/H₂O₂ oxidation. The toxicity and oestrogenic activity of BPA were largely reduced in photolytically treated samples. Photocatalytic oxidation, however, either did not reduce BPA toxic and oestrogenic effects or even increased them in comparison with the baseline, untreated BPA solution. Our findings suggest that chemical analysis is not sufficient to determine the efficiency of advanced oxidation processes in removing pollutants from water and needs to be complemented with biological tests.

  16. Application of a Dual-Arm Robot in Complex Sample Preparation and Measurement Processes.

    Science.gov (United States)

    Fleischer, Heidi; Drews, Robert Ralf; Janson, Jessica; Chinna Patlolla, Bharath Reddy; Chu, Xianghua; Klos, Michael; Thurow, Kerstin

    2016-10-01

    Automation systems with applied robotics have already been established in industrial applications for many years. In the field of life sciences, a comparable high level of automation can be found in the areas of bioscreening and high-throughput screening. Strong deficits still exist in the development of flexible and universal fully automated systems in the field of analytical measurement. Reasons are the heterogeneous processes with complex structures, which include sample preparation and transport, analytical measurements using complex sensor systems, and suitable data analysis and evaluation. Furthermore, the use of nonstandard sample vessels with various shapes and volumes results in an increased complexity. The direct use of existing automation solutions from bioscreening applications is not possible. A flexible automation system for sample preparation, analysis, and data evaluation is presented in this article. It is applied for the determination of cholesterol in biliary endoprosthesis using gas chromatography-mass spectrometry (GC-MS). A dual-arm robot performs both transport and active manipulation tasks to ensure human-like operation. This general robotic concept also enables the use of manual laboratory devices and equipment and is thus suitable in areas with a high standardization grade.

  17. Sorption/desorption processes of uranium in clayey samples of the Bangombe natural reactor zone, Gabon

    Energy Technology Data Exchange (ETDEWEB)

    Nero, M. del [Inst. de Recherches Subatomiques, CNRS/IN2P3, Strasbourg (France); Salah, S.; Clement, A.; Gauthier-Lafaye, F. [Centre de Geochimie de la Surface, CNRS, Strasbourg (France); Miura, T. [National Lab. for High Energy Physics, Tsukuba-Shi Ibaraki-Ken (Japan)

    1999-07-01

    Experimental studies have been undertaken in order to provide new insights into the relative efficiency of the different mineral phases and sorption processes for the control of U retention in the weathered zones surrounding the natural nuclear reactor at Bangombe (Oklo, Gabon). Clayey and Fe-oxihydroxides rich samples from the oxidizing weathered zones located above the reactor were examined. An experimental study of uranium adsorption/desorption processes in these samples was carried out using a uranium isotope exchange technique in order to estimate the proportion of uranium adsorbed on mineral surfaces. A sequential extraction technique was used to identify the major U-containing minerals in the samples. In the U-rich iron crust rocks close to the reactor, the fraction of total uranium adsorbed at mineral surfaces is small. Extraction experiments reveal that a large part of uranium is associated to Fe-oxihydroxides, to minor P-rich phases, and presumably to Mn-oxihydroxides. A possible mechanism for U retention is an incorporation into the structure of iron oxihydroxides and/or of ferric phosphates occurring as surface precipitates on Fe-oxihydroxides. Traces of autunite-like mineral are also present in the zone. For the clayey samples in the weathering profile, it may be inferred that several processes and minerals contribute significantly to U retention: adsorption processes occurring mainly at clay surfaces, association with traces of Mn-containing carboantes and iron oxihydroxides. A significant proportion of total U is adsorbed at mineral surfaces and is thereby easily accessible to weathering solutions. In a second part of this work, {sup 233}U sorption data obtained on a Fe- and Mn-poor illitic Bangombe sample were modeled using a surface complexation modeling approach. As a first approximation, it was assumed in modeling that uranyl binding occurs at aluminol edge sites of the illite component. The binding constant required for modeling was firstly

  18. Sampling strategies and post-processing methods for increasing the time resolution of organic aerosol measurements requiring long sample-collection times

    Science.gov (United States)

    Modini, Rob L.; Takahama, Satoshi

    2016-07-01

    The composition and properties of atmospheric organic aerosols (OAs) change on timescales of minutes to hours. However, some important OA characterization techniques typically require greater than a few hours of sample-collection time (e.g., Fourier transform infrared (FTIR) spectroscopy). In this study we have performed numerical modeling to investigate and compare sample-collection strategies and post-processing methods for increasing the time resolution of OA measurements requiring long sample-collection times. Specifically, we modeled the measurement of hydrocarbon-like OA (HOA) and oxygenated OA (OOA) concentrations at a polluted urban site in Mexico City, and investigated how to construct hourly resolved time series from samples collected for 4, 6, and 8 h. We modeled two sampling strategies - sequential and staggered sampling - and a range of post-processing methods including interpolation and deconvolution. The results indicated that relative to the more sophisticated and costly staggered sampling methods, linear interpolation between sequential measurements is a surprisingly effective method for increasing time resolution. Additional error can be added to a time series constructed in this manner if a suboptimal sequential sampling schedule is chosen. Staggering measurements is one way to avoid this effect. There is little to be gained from deconvolving staggered measurements, except at very low values of random measurement error (< 5 %). Assuming 20 % random measurement error, one can expect average recovery errors of 1.33-2.81 µg m-3 when using 4-8 h-long sequential and staggered samples to measure time series of concentration values ranging from 0.13-29.16 µg m-3. For 4 h samples, 19-47 % of this total error can be attributed to the process of increasing time resolution alone, depending on the method used, meaning that measurement precision would only be improved by 0.30-0.75 µg m-3 if samples could be collected over 1 h instead of 4 h. Devising a

  19. Cloud condensation nuclei activity and droplet activation kinetics of wet processed regional dust samples and minerals

    Science.gov (United States)

    Kumar, P.; Sokolik, I. N.; Nenes, A.

    2011-08-01

    This study reports laboratory measurements of particle size distributions, cloud condensation nuclei (CCN) activity, and droplet activation kinetics of wet generated aerosols from clays, calcite, quartz, and desert soil samples from Northern Africa, East Asia/China, and Northern America. The dependence of critical supersaturation, sc, on particle dry diameter, Ddry, is used to characterize particle-water interactions and assess the ability of Frenkel-Halsey-Hill adsorption activation theory (FHH-AT) and Köhler theory (KT) to describe the CCN activity of the considered samples. Wet generated regional dust samples produce unimodal size distributions with particle sizes as small as 40 nm, CCN activation consistent with KT, and exhibit hygroscopicity similar to inorganic salts. Wet generated clays and minerals produce a bimodal size distribution; the CCN activity of the smaller mode is consistent with KT, while the larger mode is less hydrophilic, follows activation by FHH-AT, and displays almost identical CCN activity to dry generated dust. Ion Chromatography (IC) analysis performed on regional dust samples indicates a soluble fraction that cannot explain the CCN activity of dry or wet generated dust. A mass balance and hygroscopicity closure suggests that the small amount of ions (from low solubility compounds like calcite) present in the dry dust dissolve in the aqueous suspension during the wet generation process and give rise to the observed small hygroscopic mode. Overall these results identify an artifact that may question the atmospheric relevance of dust CCN activity studies using the wet generation method. Based on the method of threshold droplet growth analysis, wet generated mineral aerosols display similar activation kinetics compared to ammonium sulfate calibration aerosol. Finally, a unified CCN activity framework that accounts for concurrent effects of solute and adsorption is developed to describe the CCN activity of aged or hygroscopic dusts.

  20. Cloud condensation nuclei activity and droplet activation kinetics of wet processed regional dust samples and minerals

    Directory of Open Access Journals (Sweden)

    P. Kumar

    2011-08-01

    Full Text Available This study reports laboratory measurements of particle size distributions, cloud condensation nuclei (CCN activity, and droplet activation kinetics of wet generated aerosols from clays, calcite, quartz, and desert soil samples from Northern Africa, East Asia/China, and Northern America. The dependence of critical supersaturation, sc, on particle dry diameter, Ddry, is used to characterize particle-water interactions and assess the ability of Frenkel-Halsey-Hill adsorption activation theory (FHH-AT and Köhler theory (KT to describe the CCN activity of the considered samples. Wet generated regional dust samples produce unimodal size distributions with particle sizes as small as 40 nm, CCN activation consistent with KT, and exhibit hygroscopicity similar to inorganic salts. Wet generated clays and minerals produce a bimodal size distribution; the CCN activity of the smaller mode is consistent with KT, while the larger mode is less hydrophilic, follows activation by FHH-AT, and displays almost identical CCN activity to dry generated dust. Ion Chromatography (IC analysis performed on regional dust samples indicates a soluble fraction that cannot explain the CCN activity of dry or wet generated dust. A mass balance and hygroscopicity closure suggests that the small amount of ions (from low solubility compounds like calcite present in the dry dust dissolve in the aqueous suspension during the wet generation process and give rise to the observed small hygroscopic mode. Overall these results identify an artifact that may question the atmospheric relevance of dust CCN activity studies using the wet generation method.

    Based on the method of threshold droplet growth analysis, wet generated mineral aerosols display similar activation kinetics compared to ammonium sulfate calibration aerosol. Finally, a unified CCN activity framework that accounts for concurrent effects of solute and adsorption is developed to

  1. Aggregation and sampling in deterministic chaos: implications for chaos identification in hydrological processes

    Directory of Open Access Journals (Sweden)

    J. D. Salas

    2005-01-01

    Full Text Available A review of the literature reveals conflicting results regarding the existence and inherent nature of chaos in hydrological processes such as precipitation and streamflow, i.e. whether they are low dimensional chaotic or stochastic. This issue is examined further in this paper, particularly the effect that certain types of transformations, such as aggregation and sampling, may have on the identification of the dynamics of the underlying system. First, we investigate the dynamics of daily streamflows for two rivers in Florida, one with strong surface and groundwater storage contributions and the other with a lesser basin storage contribution. Based on estimates of the delay time, the delay time window, and the correlation integral, our results suggest that the river with the stronger basin storage contribution departs significantly from the behavior of a chaotic system, while the departure is less significant for the river with the smaller basin storage contribution. We pose the hypothesis that the chaotic behavior depicted on continuous precipitation fields or small time-step precipitation series becomes less identifiable as the aggregation (or sampling time step increases. Similarly, because streamflows result from a complex transformation of precipitation that involves accumulating and routing excess rainfall throughout the basin and adding surface and groundwater flows, the end result may be that streamflows at the outlet of the basin depart from low dimensional chaotic behavior. We also investigate the effect of aggregation and sampling using series derived from the Lorenz equations and show that, as the aggregation and sampling scales increase, the chaotic behavior deteriorates and eventually ceases to show evidence of low dimensional determinism.

  2. Influence of visualization on consumption during on-line shopping

    OpenAIRE

    Hictaler, Urška

    2013-01-01

    This diploma work studies the influence of visualization on consumption during on-line shopping. The first part of the thesis starts with key areas of visualization, consumption and on-line shopping. Visualization, areas of use, human perception and ways of product presentation in on-line shops are defined discussed first. Next, consumption, consumers and factors that influence their decisions and satisfaction are defined. The last topic in the first part of the thesis discusses on-line shopp...

  3. On-line near infrared bioreactor monitoring of cell density and concentrations of glucose and lactate during insect cell cultivation.

    Science.gov (United States)

    Qiu, Jiang; Arnold, Mark A; Murhammer, David W

    2014-03-10

    Near infrared spectroscopy is demonstrated as a suitable method for monitoring real time cell density and concentrations of glucose and lactate during insect cell cultivation. The utility of this approach is illustrated during the cultivation of Trichoplusia ni BTI-Tn-5B1-4 insect cells in a stirred-tank bioreactor. On-line near infrared measurements are made by passing unaltered culture medium through an autoclavable near infrared flow-through sample cell during the cultivation process. Single-beam near infrared spectra were collected over the combination spectral range (5000-4000cm(-1)) through a 1.5mm path length sample. Cell density calibration model was established by uni-variable linear regressions with measured mean absorbance values of on-line spectra collected during a cultivation run. Calibration models are generated for glucose and lactate by regression analysis of both off line and on line spectra collected during a series of pre-measurement cultivation runs. Analyte-specific calibration models are generated by using a combination of spectra from both natural, unaltered samples and samples spiked with known levels of glucose and lactate. Spiked samples are used to destroy concentration correlations between solutes, thereby enhancing the selectivity of the calibration models. Absorbance spectra are used to build partial least squares calibration models for glucose and lactate. The calibration model for cell density corresponds to a univariate linear regression calibration model based on the mean absorbance between 4750 and 4250cm(-1). The standard errors of prediction are 1.54mM, 0.83mM, and 0.38×10(6)cells/mL for the glucose, lactate, and cell density models, respectively.

  4. On-Line Learning: One Way to Bring People Together

    Science.gov (United States)

    Goff-Kfouri, Carol Ann

    2006-01-01

    The purpose of this study was to demonstrate the benefits of on-line learning for adult learners and to further demystify three common misconceptions concerning on-line learning: students certainly do receive support from their on-line professors, the professor is pro-active rather than passive, and students may be more motivated to learn than in…

  5. A Distributed System for Learning Programming On-Line

    Science.gov (United States)

    Verdu, Elena; Regueras, Luisa M.; Verdu, Maria J.; Leal, Jose P.; de Castro, Juan P.; Queiros, Ricardo

    2012-01-01

    Several Web-based on-line judges or on-line programming trainers have been developed in order to allow students to train their programming skills. However, their pedagogical functionalities in the learning of programming have not been clearly defined. EduJudge is a project which aims to integrate the "UVA On-line Judge", an existing…

  6. CHARACTERIZATION OF A PRECIPITATE REACTOR FEED TANK (PRFT) SAMPLE FROM THE DEFENSE WASTE PROCESSING FACILITY (DWPF)

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C.; Bannochie, C.

    2014-05-12

    A sample of from the Defense Waste Processing Facility (DWPF) Precipitate Reactor Feed Tank (PRFT) was pulled and sent to the Savannah River National Laboratory (SRNL) in June of 2013. The PRFT in DWPF receives Actinide Removal Process (ARP)/ Monosodium Titanate (MST) material from the 512-S Facility via the 511-S Facility. This 2.2 L sample was to be used in small-scale DWPF chemical process cell testing in the Shielded Cells Facility of SRNL. A 1L sub-sample portion was characterized to determine the physical properties such as weight percent solids, density, particle size distribution and crystalline phase identification. Further chemical analysis of the PRFT filtrate and dissolved slurry included metals and anions as well as carbon and base analysis. This technical report describes the characterization and analysis of the PRFT sample from DWPF. At SRNL, the 2.2 L PRFT sample was composited from eleven separate samples received from DWPF. The visible solids were observed to be relatively quick settling which allowed for the rinsing of the original shipping vials with PRFT supernate on the same day as compositing. Most analyses were performed in triplicate except for particle size distribution (PSD), X-ray diffraction (XRD), Scanning Electron Microscopy (SEM) and thermogravimetric analysis (TGA). PRFT slurry samples were dissolved using a mixed HNO3/HF acid for subsequent Inductively Coupled Plasma Atomic Emission Spectroscopy (ICPAES) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) analyses performed by SRNL Analytical Development (AD). Per the task request for this work, analysis of the PRFT slurry and filtrate for metals, anions, carbon and base were primarily performed to support the planned chemical process cell testing and to provide additional component concentrations in addition to the limited data available from DWPF. Analysis of the insoluble solids portion of the PRFT slurry was aimed at detailed characterization of these solids (TGA, PSD

  7. Optimization of a sample processing protocol for recovery of Bacillus anthracis spores from soil

    Science.gov (United States)

    Silvestri, Erin E.; Feldhake, David; Griffin, Dale; Lisle, John T.; Nichols, Tonya L.; Shah, Sanjiv; Pemberton, A; Schaefer III, Frank W

    2016-01-01

    Following a release of Bacillus anthracis spores into the environment, there is a potential for lasting environmental contamination in soils. There is a need for detection protocols for B. anthracis in environmental matrices. However, identification of B. anthracis within a soil is a difficult task. Processing soil samples helps to remove debris, chemical components, and biological impurities that can interfere with microbiological detection. This study aimed to optimize a previously used indirect processing protocol, which included a series of washing and centrifugation steps. Optimization of the protocol included: identifying an ideal extraction diluent, variation in the number of wash steps, variation in the initial centrifugation speed, sonication and shaking mechanisms. The optimized protocol was demonstrated at two laboratories in order to evaluate the recovery of spores from loamy and sandy soils. The new protocol demonstrated an improved limit of detection for loamy and sandy soils over the non-optimized protocol with an approximate matrix limit of detection at 14 spores/g of soil. There were no significant differences overall between the two laboratories for either soil type, suggesting that the processing protocol will be robust enough to use at multiple laboratories while achieving comparable recoveries.

  8. Collection and processing of plant, animal and soil samples from Bikini, Enewetak and Rongelap Atolls

    Energy Technology Data Exchange (ETDEWEB)

    Stuart, M.L.

    1995-09-01

    The United States used the Marshall Islands for its nuclear weapons program testing site from 1946 to 1958. The BRAVO test was detonated at Bikini Atoll on March 1, 1954. Due to shifting wind conditions at the time of the nuclear detonation, many of the surrounding Atolls became contaminated with fallout (radionuclides carried by the wind currents). Lawrence Livermore National Laboratory`s (LLNL) Marshall Islands Project has been responsible for the collecting, processing, and analyzing of food crops, vegetation, soil, water, animals, and marine species to characterize the radionuclides in the environment, and to estimate dose at atolls that may have been contaminated. Tropical agriculture experiments reducing the uptake of {sup 137}Cs have been conducted on Bikini Atoll. The Marshall Islands field team and laboratory processing team play an important role in the overall scheme of the Marshall Islands Dose Assessment and Radioecology Project. This report gives a general description of the Marshall Islands field sampling and laboratory processing procedures currently used by our staff.

  9. Optimization of a sample processing protocol for recovery of Bacillus anthracis spores from soil.

    Science.gov (United States)

    Silvestri, Erin E; Feldhake, David; Griffin, Dale; Lisle, John; Nichols, Tonya L; Shah, Sanjiv R; Pemberton, Adin; Schaefer, Frank W

    2016-11-01

    Following a release of Bacillus anthracis spores into the environment, there is a potential for lasting environmental contamination in soils. There is a need for detection protocols for B. anthracis in environmental matrices. However, identification of B. anthracis within a soil is a difficult task. Processing soil samples helps to remove debris, chemical components, and biological impurities that can interfere with microbiological detection. This study aimed to optimize a previously used indirect processing protocol, which included a series of washing and centrifugation steps. Optimization of the protocol included: identifying an ideal extraction diluent, variation in the number of wash steps, variation in the initial centrifugation speed, sonication and shaking mechanisms. The optimized protocol was demonstrated at two laboratories in order to evaluate the recovery of spores from loamy and sandy soils. The new protocol demonstrated an improved limit of detection for loamy and sandy soils over the non-optimized protocol with an approximate matrix limit of detection at 14spores/g of soil. There were no significant differences overall between the two laboratories for either soil type, suggesting that the processing protocol will be robust enough to use at multiple laboratories while achieving comparable recoveries. Copyright © 2016. Published by Elsevier B.V.

  10. Development of a simple device for processing whole-blood samples into measured aliquots of plasma.

    Science.gov (United States)

    Burtis, C A; Johnson, W F; Walker, W A

    1986-09-01

    A capillary processor and aliquoter has been designed and fabricated that is capable of accepting aliquots of whole blood and automatically processing them into discrete aliquots of plasma. The device consists of two disks, each of which contains 16 individual capillaries and a processing rotor. One disk accepts larger capillaries that hold approximately 100 microL of whole blood each. The second disk accepts 2.54-cm-long precision capillaries of various internal diameters, which provide exact sample volumes from 1 to 10 microL. The processing rotor contains 16 individual compartments and chambers to accept both disks. Applying centrifugal force transfers the aliquots of whole blood into their respective compartments, where they are separated into cellular and plasma fractions. As the rotor speed is slowly decreased, an aliquot of plasma is withdrawn by capillary action into each measuring capillary. The disk containing the 16 measured aliquots of plasma is then removed and placed into a modified rotor for conventional centrifugal analysis. This device can entrain and deliver microliter volumes of liquids with precision and accuracy (1-2%) near that of mechanical pipettes. Assays of the separated plasma aliquots also have acceptable precision (e.g., CVs approximately 3% for measurements of serum enzymes).

  11. On-Line Control of Metal Processing. Report of the Committee on On-Line Control of Metal Processing

    Science.gov (United States)

    1989-02-01

    spot welding. The signals from the norma . sources of welding (such as set-down) and the detection of cracking allows closed-loop feedback control of the...TMS/AIME, ASM International, ASTM , ASME, MRS, and APS. 101 102 DONALD R. SADOWAY received his B.A.Sc., M.A.Sc. and Ph.D. (in metallurgy) from the

  12. SOL: INNOVACIÓN ON-LINE

    Directory of Open Access Journals (Sweden)

    Rubén Faúndez

    2007-11-01

    Full Text Available Las aplicaciones de simulación tienden a ser cada vez más cercanas a usuarios e industrias. Sin embargo, muchas de ellas no poseen ni la capacidad ni el conocimiento como para desarrollar internamente sus modelos de simulación. Por este motivo, y como una forma de apoyar la toma de decisiones basándose en modelos de simulación, se presenta la plataforma SOL (Simulación On Line. La metodología completa de trabajo, así como la interacción entre SOL, Empresa y Asesor, son presentadas. Su base de datos, los niveles de usuarios, sus funcionalidades, y la creación automatizada de información grafica y visual, también son explicadas. En el caso de aplicación, el uso de SOL para apoyar la toma de decisiones en una operación de movimiento de material, permite a los tomadores de decisión acceder a análisis robustos basados en información extraída de los modelos de simulación. SOL, al almacenar información, funcionar vía web, generar análisis automatizados y crear visualizaciones, permite cumplir con las expectativas de los usuarios respecto a una solución integral en simulación.

  13. The Monitor System for the LHCb on-line farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2005-01-01

    The aim of the LHCb on-line farm Monitor System is to keep under control all the working indicators which are relevant for the farm operation, and to set the appropriate alarms whenever an error or a critical condition comes up. Since the most stressing tasks of the farm are the data transfer and processing, relevant indicators includes the CPU and the memory load of the system, the network interface and the TCP/IP stack parameters, the rates of the interrupts raised by the network interface card and the detailed status of the running processes. The monitoring of computers’ physical conditions (temperatures, fan speeds and motherboard voltages) are the subject of a separate technical note, since they are accessed in a different way, by using the IPMI protocol.

  14. The Message Logger for the LHCb on-line farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2005-01-01

    The Message Logger is a utility which provide a logger facility for the processes running on the nodes of the on-line farm. It can also be used to collect the processes stdout/stderr. The Message Logger can be exploited using two different policies: either as a no-drop logger facility (messages cannot be lost, but a write to the logger facility blocks in case of full-buffer condition, due e.g. to a network congestion) or as a congestion-proof logger facility (a write to the logger facility never locks even in case of network congestion, but, in this case, messages are dropped). The Message Logger package includes a Linux DIM server (logSrv), a Linux terminal/command-line DIM client (logViewer) and a PVSS DIM client.

  15. Onboard infrared signal processing system for asteroid sample return mission HAYABUSA2

    Science.gov (United States)

    Otake, Hisashi; Okada, Tatsuaki; Funase, Ryu; Hihara, Hiroki; Sano, Junpei; Iwase, Kaori; Kawakami, Satoko; Takada, Jun; Masuda, Tetsuya

    2014-09-01

    Onboard signal processing system for infrared sensors has been developed for HAYABUSA2 for the exploration of C class near-Earth asteroid 162173 (1999JU3), which is planned to be launched in 2014. An optical navigation camera with telephoto lens (ONC-T), a thermal-infrared imager (TIR), and a near infrared spectrometer (NIRS3) have been developed for the observation of geology, thermo-physical properties, and organic or hydrated materials on the asteroid. ONC-T and TIR are used for those scientific purposes as well as assessment of landing site selection and safe descent operation onto the asteroid surface for sample acquisition. NIRS3 is used to characterize the mineralogy of the asteroid surface by observing the 3-micron band, where the particular diagnostic absorption features due to hydrated minerals appear. Since the processing cycle of these sensors are independent, data processing, formatting and recording are processed in parallel. In order to provide the functions within the resource limitation of deep space mission, automatic packet routing function is realized in one chip router with SpaceWire standard. Thanks to the SpaceWire upper layer protocol (remote memory access protocol: RMAP), the variable length file system operation function can be delegated to the data recorder from the CPU module of the digital electronics of the sensor system. In consequence the infrared spectrometer data from NIRS3 is recorded in parallel with the infrared image sensors. High speed image compression algorithm is also developed for both lossless and lossy image compression in order to eliminate additional hardware resource while maintaining the JPEG2000 equivalent image quality.

  16. Quantification of process induced disorder in milled samples using different analytical techniques

    DEFF Research Database (Denmark)

    Zimper, Ulrike; Aaltonen, Jaakko; McGoverin, Cushla M.

    2012-01-01

    The aim of this study was to compare three different analytical methods to detect and quantify the amount of crystalline disorder/ amorphousness in two milled model drugs. X-ray powder diffraction (XRPD), differential scanning calorimetry (DSC) and Raman spectroscopy were used as analytical methods......-induced crystalline disorder/ amorphousness under different process conditions. In the DSC measurements the change in heat capacity at the glass transition was used for quantification. Differently prepared amorphous indomethacin standards (prepared by either melt quench cooling or cryo milling) were compared...... to crystalline disorder for milled drugs depends on the analytical method used and the calibration standard chosen as well as on the drug itself. From the data presented here, it appears that XRPD tends to give a higher percentage of crystalline disorder than Raman spectroscopy and DSC for the same samples...

  17. Average Sample-path Optimality for Continuous-time Markov Decision Processes in Polish Spaces

    Institute of Scientific and Technical Information of China (English)

    Quan-xin ZHU

    2011-01-01

    In this paper we study the average sample-path cost (ASPC) problem for continuous-time Markov decision processes in Polish spaces.To the best of our knowledge,this paper is a first attempt to study the ASPC criterion on continuous-time MDPs with Polish state and action spaces.The corresponding transition rates are allowed to be unbounded,and the cost rates may have neither upper nor lower bounds.Under some mild hypotheses,we prove the existence of e (ε ≥ 0)-ASPC optimal stationary policies based on two different approaches:one is the “optimality equation” approach and the other is the “two optimality inequalities” approach.

  18. Routine processing procedures for isolating filamentous fungi from respiratory sputum samples may underestimate fungal prevalence.

    Science.gov (United States)

    Pashley, Catherine H; Fairs, Abbie; Morley, Joseph P; Tailor, Shreeya; Agbetile, Joshua; Bafadhel, Mona; Brightling, Christopher E; Wardlaw, Andrew J

    2012-05-01

    Colonization of the airways by filamentous fungi can occur in asthma, chronic obstructive pulmonary disease (COPD) and cystic fibrosis. A recent study found IgE sensitization to Aspergillus fumigatus to be associated with reduced lung function. Significantly higher rates of A. fumigatus were detected in sputum from asthmatics sensitized to this fungus compared to non-sensitized asthmatics. The rate of positive cultures was far higher than equivalent historical samples analysed by the local clinical laboratory following protocols recommended by the UK Health Protection Agency (HPA). This study compares the HPA procedure with our sputum processing method, whereby sputum plugs are separated from saliva and aliquots of approximately 150 mg are inoculated directly onto potato dextrose agar. A total of 55 sputum samples from 41 patients with COPD were analyzed, comparing fungal recovery of five dilutions of sputa on two media. Isolation of A. fumigatus in culture was significantly higher using the research approach compared to the HPA standard method for mycological investigations (P < 0.001). There was also a significant difference in the recovery rate of A. fumigatus (P < 0.05) between media. This highlights the need for a standardized approach to fungal detection which is more sensitive than the method recommended by the HPA.

  19. Precise On-line Position Measurement for Particle Therapy

    CERN Document Server

    Actis, O; König, S

    2014-01-01

    An on-line beam position monitoring and regular beam stability tests are of utmost importance for the Quality Assurance (QA) of the patient treatment at any particle therapy facility. The Gantry${0.5 mm}2$ at the Paul Scherrer Institute uses a strip ionization chamber for the on-line beam position verification. The design of the strip chamber placed in the beam in front of the patient allows for a small beam penumbra in order to achieve a high-quality lateral beam delivery. The detector granularity and the low noise allow the reconstruction of the signals offered by Gantry${0.5 mm}2$ with a precision of about 0.1 mm. The frond-end electronics and the whole data processing sequence have been optimized for minimizing the dead time between the beam applications to about 2 ms: the charge collection is performed in about 1 ms, read-out takes place in 100 $\\mu$s while data verification and logging are completed in less than 1 ms. The sub-millimeter precision of the lateral reconstruction allows the dose inhomogenei...

  20. REMOTE IN-CELL SAMPLING IMPROVEMENTS PROGRAM AT THESAVANNAH RIVER SITE (SRS) DEFENSE WASTE PROCESSING FACILITY (DWPF)

    Energy Technology Data Exchange (ETDEWEB)

    Marzolf, A

    2007-11-26

    Remote Systems Engineering (RSE) of the Savannah River National Lab (SRNL) in combination with the Defense Waste Processing Facility(DWPF) Engineering and Operations has evaluated the existing equipment and processes used in the facility sample cells for 'pulling' samples from the radioactive waste stream and performing equipment in-cell repairs/replacements. RSE has designed and tested equipment for improving remote in-cell sampling evolutions and reducing the time required for in-cell maintenance of existing equipment. The equipment within the present process tank sampling system has been in constant use since the facility start-up over 17 years ago. At present, the method for taking samples within the sample cells produces excessive maintenance and downtime due to frequent failures relative to the sampling station equipment and manipulator. Location and orientation of many sampling stations within the sample cells is not conducive to manipulator operation. The overextension of manipulators required to perform many in-cell operations is a major cause of manipulator failures. To improve sampling operations and reduce downtime due to equipment maintenance, a Portable Sampling Station (PSS), wireless in-cell cameras, and new commercially available sampling technology has been designed, developed and/or adapted and tested. The uniqueness of the design(s), the results of the scoping tests, and the benefits relative to in-cell operation and reduction of waste are presented.

  1. Sampling methods for the quasistationary regime of epidemic processes on regular and complex networks

    Science.gov (United States)

    Sander, Renan S.; Costa, Guilherme S.; Ferreira, Silvio C.

    2016-10-01

    A major hurdle in the simulation of the steady state of epidemic processes is that the system will unavoidably visit an absorbing, disease-free state at sufficiently long times due to the finite size of the networks where epidemics evolves. In the present work, we compare different quasistationary (QS) simulation methods where the absorbing states are suitably handled and the thermodynamical limit of the original dynamics can be achieved. We analyze the standard QS (SQS) method, where the sampling is constrained to active configurations, the reflecting boundary condition (RBC), where the dynamics returns to the pre-absorbing configuration, and hub reactivation (HR), where the most connected vertex of the network is reactivated after a visit to an absorbing state. We apply the methods to the contact process (CP) and susceptible-infected-susceptible (SIS) models on regular and scale free networks. The investigated methods yield the same epidemic threshold for both models. For CP, that undergoes a standard collective phase transition, the methods are equivalent. For SIS, whose phase transition is ruled by the hub mutual reactivation, the SQS and HR methods are able to capture localized epidemic phases while RBC is not. We also apply the autocorrelation time as a tool to characterize the phase transition and observe that this analysis provides the same finite-size scaling exponents for the critical relaxation time for the investigated methods. Finally, we verify the equivalence between RBC method and a weak external field for epidemics on networks.

  2. On-line alkali detector based on surface ionization

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, J.G.; Loenn, B.; Jaeglid, B.; Engvall, K.; Pettersson, J.B.C. [Chalmers University of Technology, Goeteborg (Sweden). Dept. of Physical Chemistry GU

    1998-12-31

    This project adapts a new on-line alkali measurement technique to coal and biomass combustion and gasification. Alkali metal atoms are known to easily ionize in contact with hot metal surfaces, and the instrument is based on this principle called surface ionization (SI). The primary parts of the detector are a platinum filament and an ion collector. The platinum filament is supported between two electrodes and heated to the temperature for alkali vaporization in ionic form. The ion collector is situated close to the filament. The measured current is proportional to the arrival rate of alkali atoms onto the filament. Laboratory tests were performed on detector sensitivity, detection limit, and time response. Similar sensitivity to both sodium and potassium regardless of molecular form was found. The time response of the detector is determined to be approximately 1 ms enabling it to monitor fast concentration changes in flue gas. Particles with a size below 5 nm melt completely on the hot platinum surface and give similar signals. For larger particles, the ionization efficiency is not 100% and depends on the type of salt. This problem can be overcome with an alternative filament configuration. The detector function was tested in a laboratory high pressure furnace using different fuel samples, atmospheres, and pressures. Alkali release from coal in general is lower than for biomass samples, rate constants and activation energies for alkali release were determined. Measurements were carried out in a biomass pyrolysis apparatus and a gasification pilot plant. The detector function was not influenced by a high concentration of hydrocarbons in the gas phase, and the measurements confirmed detector function in a hostile environment. The detector performed well in laboratory tests, and is a strong candidate for further development into a standard on-line monitor of alkali species in hot flue gas. 10 refs., 16 figs.

  3. Diagnosis and processing of detector failure in PWR on-line power distribution monitoring%压水堆堆芯功率分布在线监测计算中的探测器失效诊断与处理方法

    Institute of Scientific and Technical Information of China (English)

    李茁; 吴宏春; 曹良志; 李云召; 刘宙宇

    2017-01-01

    Measurements of in-core detectors,as one of the most important inputs for a reactor core on-line power distribu-tion monitoring system,seriously affect the on-line monitoring results.Therefore,the diagnosis and processing of detector failure are necessary.Harmonics expansion method is employed to the on-line monitoring calculation of reactor core power distribution. To diagnose failure of detectors,three methods— direct method,comparison of measurements method and comparison of recon-structed responses method—are used in combination.Based on these methods,diagnosis and processing of detector failure have been added into NECP-ONION,an in-house online monitoring code developed by NECP Lab.Benchmark for Evaluation and Vali-dation Reactor Simulations(BEAVRS)has been used for code validation,especially for the diagnosis and processing of detector failure.Numerical results show that,the combination of these three methods is not only effective to the complete failed condition, but also useful for measurements deviation of normal value.In addition,NECP-ONION is functional to distinguish detector fail-ure or local power oscillation.This could reduce the misdiagnosis for detector failure.For the processing of detector failure,it has been observed that single detector failure or a small number of detectors failed has limit effect on the monitoring system NECP-ONION.%作为堆芯功率分布在线监测计算的重要输入参数,堆内中子探测器的测量数据对堆芯功率分布在线监测具有重要影响,因此在线监测计算中探测器失效的诊断和处理十分必要。采用谐波展开法进行堆芯功率分布的在线监测计算,采用直接观察法、探测器测量值比较法以及探测器重构值比较法分三个阶段对探测器失效进行诊断。基于以上理论,在在线监测系统 NECP-ONION中加入探测器失效诊断功能,利用BEAVRS基准题对失效诊断和处理进行验证。数值结果表明,将三阶段的诊断

  4. Research on the Influence of Perceived Risk in Consumer On-line Purchasing Decision

    Science.gov (United States)

    Hong, Zhao; Yi, Li

    Perceived risk is an important factor that affects consumer's on-line shopping purchasing decision, through the perceived theories the consumer can know clearly which step owns higher risk in the whole shopping process, then learn how to prevent it, this process also strengthen the consumer confidence, thus lowering to know that the risk adjudicate to the feeling, so the essay has important and realistic meaning for further expand the electronic commerce. At first, investigate, collect, tidy up, analyze the questionnaire information, and thus get the primary data. Finally try to find out the influence of perceived risk to each stage of purchasing decision during consumer on-line shopping process with data and personal analytical. The paper is a complement to the local and existing perceived theories. The result of the study manifests that, the order of main perceived risks which felt by consumer during on-line shopping process are as follow: financial risk, the performance risk and service risk.

  5. Standardization developments for large scale biobanks in smoking related diseases - a model system for blood sample processing and storage.

    Science.gov (United States)

    Malm, Johan; Fehniger, Thomas E; Danmyr, Pia; Végvári, Ákos; Welinder, Charlotte; Lindberg, Henrik; Upton, Paul; Carter, Stephanie; Appelqvist, Roger; Sjödin, Karin; Wieslander, Elisabet; Dahlbäck, Magnus; Rezeli, Melinda; Erlinge, David; Marko-Varga, György

    2013-12-01

    Biobank samples stored in biobanks give researchers and respiratory healthcare institutions access to datasets of analytes valuable for both diagnostic and research practices. The usefulness of these samples in clinical decision-making is highly dependent on their quality and integrity. New procedures that better preserve sample integrity and reduce degradation are being developed to meet the needs of both present and future biobanking. Hereby we present an automatic sample workflow scheme that is designed to handle high numbers of blood samples. Blood fractions are aliquoted, heat sealed using novel technology, and stored in 384 tube high-density sample arrays. The newly developed 384 biobank rack system is especially suited for preserving identical small aliquots. We provide data on robotic processing of clinical samples at -80°C, following initial processing, analysis and shipping between laboratories throughout Europe. Subsequent to unpacking, re-sorting, and storage at these sites, the samples have been returned for analysis. Biomarker analysis of 13 common tests in the clinical chemistry unit of the hospital provides evidence of qualitative and stable logistics using the 384-sample tube system. This technology development allows rapid access to a given sample in the frozen archive while maintaining individual sample integrity with sample tube confinement and quality management.

  6. On-line methods for rotorcraft aeroelastic mode identification

    Science.gov (United States)

    Molusis, J. A.; Kleinman, D. L.

    1982-01-01

    The requirements for the on-line identification of rotorcraft aeroelastic blade modes from random response test data are presented. A recursive maximum likelihood (RML) technique is used in conjunction with a bandpass filter to identify isolated blade mode damping and frequency. The RML technique is demonstrated to have excellent convergence characteristics in random measurement noise and random process noise excitation. The RML identification technique uses an ARMA representation for the aeroelastic stochastic system and requires virtually no user interaction while providing accurate confidence bands on the parameter estimates. Comparisons are made with an off-line Newton type maximum likelihood algorithm which uses a state variable model representation. Results are presented from simulation random response data which quantify the identifed parameter convergence behavior for various levels of random excitation which is typical of wind tunnel turbulence levels. The RML technique is applied to hingless rotor test data from the NASA Langley Research Center Helicopter Hover Facility.

  7. On-line range images registration with GPGPU

    Science.gov (United States)

    Będkowski, J.; Naruniec, J.

    2013-03-01

    This paper concerns implementation of algorithms in the two important aspects of modern 3D data processing: data registration and segmentation. Solution proposed for the first topic is based on the 3D space decomposition, while the latter on image processing and local neighbourhood search. Data processing is implemented by using NVIDIA compute unified device architecture (NIVIDIA CUDA) parallel computation. The result of the segmentation is a coloured map where different colours correspond to different objects, such as walls, floor and stairs. The research is related to the problem of collecting 3D data with a RGB-D camera mounted on a rotated head, to be used in mobile robot applications. Performance of the data registration algorithm is aimed for on-line processing. The iterative closest point (ICP) approach is chosen as a registration method. Computations are based on the parallel fast nearest neighbour search. This procedure decomposes 3D space into cubic buckets and, therefore, the time of the matching is deterministic. First technique of the data segmentation uses accele-rometers integrated with a RGB-D sensor to obtain rotation compensation and image processing method for defining pre-requisites of the known categories. The second technique uses the adapted nearest neighbour search procedure for obtaining normal vectors for each range point.

  8. Tank vapor sampling and analysis data package for tank 241-C-106 waste retrieval sluicing system process test phase III

    Energy Technology Data Exchange (ETDEWEB)

    LOCKREM, L.L.

    1999-08-13

    This data package presents sampling data and analytical results from the March 28, 1999, vapor sampling of Hanford Site single-shell tank 241-C-106 during active sluicing. Samples were obtained from the 296-C-006 ventilation system stack and ambient air at several locations. Characterization Project Operations (CPO) was responsible for the collection of all SUMMATM canister samples. The Special Analytical Support (SAS) vapor team was responsible for the collection of all triple sorbent trap (TST), sorbent tube train (STT), polyurethane foam (PUF), and particulate filter samples collected at the 296-C-006 stack. The SAS vapor team used the non-electrical vapor sampling (NEVS) system to collect samples of the air, gases, and vapors from the 296-C-006 stack. The SAS vapor team collected and analyzed these samples for Lockheed Martin Hanford Corporation (LMHC) and Tank Waste Remediation System (TWRS) in accordance with the sampling and analytical requirements specified in the Waste Retrieval Sluicing System Vapor Sampling and Analysis Plan (SAP) for Evaluation of Organic Emissions, Process Test Phase III, HNF-4212, Rev. 0-A, (LMHC, 1999). All samples were stored in a secured Radioactive Materials Area (RMA) until the samples were radiologically released and received by SAS for analysis. The Waste Sampling and Characterization Facility (WSCF) performed the radiological analyses. The samples were received on April 5, 1999.

  9. Data Validation Package October 2016 Groundwater and Surface Water Sampling at the Monticello, Utah, Disposal and Processing Sites January 2017

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Jason [USDOE Office of Legacy Management (LM), Washington, DC (United States); Smith, Fred [Navarro Research and Engineering, Inc., Grand Junction, CO (United States)

    2017-02-01

    Sampling Period: October 10–12, 2016. This semiannual event includes sampling groundwater and surface water at the Monticello Disposal and Processing Sites. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated) and Program Directive MNT-2016-01. Samples were collected from 54 of 64 planned locations (16 of 17 former mill site wells, 15 of 18 downgradient wells, 7 of 9 downgradient permeable reactive barrier wells, 3 of 3 bedrock wells, 4 of 7 seeps and wetlands, and 9 of 10 surface water locations).

  10. Quantifying Next Generation Sequencing Sample Pre-Processing Bias in HIV-1 Complete Genome Sequencing.

    Science.gov (United States)

    Vrancken, Bram; Trovão, Nídia Sequeira; Baele, Guy; van Wijngaerden, Eric; Vandamme, Anne-Mieke; van Laethem, Kristel; Lemey, Philippe

    2016-01-07

    Genetic analyses play a central role in infectious disease research. Massively parallelized "mechanical cloning" and sequencing technologies were quickly adopted by HIV researchers in order to broaden the understanding of the clinical importance of minor drug-resistant variants. These efforts have, however, remained largely limited to small genomic regions. The growing need to monitor multiple genome regions for drug resistance testing, as well as the obvious benefit for studying evolutionary and epidemic processes makes complete genome sequencing an important goal in viral research. In addition, a major drawback for NGS applications to RNA viruses is the need for large quantities of input DNA. Here, we use a generic overlapping amplicon-based near full-genome amplification protocol to compare low-input enzymatic fragmentation (Nextera™) with conventional mechanical shearing for Roche 454 sequencing. We find that the fragmentation method has only a modest impact on the characterization of the population composition and that for reliable results, the variation introduced at all steps of the procedure--from nucleic acid extraction to sequencing--should be taken into account, a finding that is also relevant for NGS technologies that are now more commonly used. Furthermore, by applying our protocol to deep sequence a number of pre-therapy plasma and PBMC samples, we illustrate the potential benefits of a near complete genome sequencing approach in routine genotyping.

  11. Chemical process based reconstruction of exposures for an epidemiological study. III. Analysis of industrial hygiene samples.

    Science.gov (United States)

    Hall, Thomas A; Esmen, Nurtan A; Jones, Elizabeth P; Basara, Heather; Phillips, Margaret L; Marsh, Gary M; Youk, Ada O; Buchanich, Jeanine M; Leonard, Robin C

    2007-03-20

    As part of an historical cohort study to investigate the mortality experience of industrial workers exposed to chloroprene (beta-CD) and other substances, all available industrial hygiene exposure monitoring data were collected and summarized. From discussions with on-site industrial hygiene personnel, it was apparent that these data were not collected for epidemiological purposes and, therefore, their use in characterization of exposures was problematic as the data mostly pertained to samples collected to investigate the performance of specific tasks. These data were, however, informative for validating the exposure modeling process used to estimate historical exposures. The data summarized below clearly indicate that exposures to beta-CD were lowered across the time period of this study. Typically, the exposures recorded were less than the occupational exposure limits of the periods in which the exposures were recorded. Additionally, exposure measurements recorded in the recent past do not represent the exposure actually experienced by the worker as a strict personal protective equipment use program has been in place for the facilities studied since the mid-1980s.

  12. Quantifying Next Generation Sequencing Sample Pre-Processing Bias in HIV-1 Complete Genome Sequencing

    Directory of Open Access Journals (Sweden)

    Bram Vrancken

    2016-01-01

    Full Text Available Genetic analyses play a central role in infectious disease research. Massively parallelized “mechanical cloning” and sequencing technologies were quickly adopted by HIV researchers in order to broaden the understanding of the clinical importance of minor drug-resistant variants. These efforts have, however, remained largely limited to small genomic regions. The growing need to monitor multiple genome regions for drug resistance testing, as well as the obvious benefit for studying evolutionary and epidemic processes makes complete genome sequencing an important goal in viral research. In addition, a major drawback for NGS applications to RNA viruses is the need for large quantities of input DNA. Here, we use a generic overlapping amplicon-based near full-genome amplification protocol to compare low-input enzymatic fragmentation (Nextera™ with conventional mechanical shearing for Roche 454 sequencing. We find that the fragmentation method has only a modest impact on the characterization of the population composition and that for reliable results, the variation introduced at all steps of the procedure—from nucleic acid extraction to sequencing—should be taken into account, a finding that is also relevant for NGS technologies that are now more commonly used. Furthermore, by applying our protocol to deep sequence a number of pre-therapy plasma and PBMC samples, we illustrate the potential benefits of a near complete genome sequencing approach in routine genotyping.

  13. On-line regeneration of hydrodesulfurization catalyst

    Science.gov (United States)

    Preston, Jr., John L.

    1980-01-01

    A hydrotreating catalyst is regenerated as it concurrently hydrotreats a hydrocarbon fuel by introducing a low concentration of oxygen into the catalyst bed either continuously or periodically. At low oxygen concentrations the carbon deposits on the catalyst are burned off without harming the catalyst and without significantly affecting the hydrotreating process. In a preferred embodiment the hydrotreating process is hydrodesulfurization, and regenerating is done periodically with oxygen concentrations between 0.1 and 0.5 volume percent.

  14. Emerging halogenated flame retardants and hexabromocyclododecanes in food samples from an e-waste processing area in Vietnam.

    Science.gov (United States)

    Tao, Fang; Matsukami, Hidenori; Suzuki, Go; Tue, Nguyen Minh; Viet, Pham Hung; Takigami, Hidetaka; Harrad, Stuart

    2016-03-01

    This study reports concentrations of selected emerging halogenated flame retardants (HFRs) and hexabromocyclododecanes (HBCDs) in foodstuffs sourced from an e-waste processing area in Vietnam and two reference sites in Vietnam and Japan. Concentrations of all target HFRs in e-waste-impacted samples in this study exceed significantly (p e-waste processing activities exert a substantial impact on local environmental contamination and human dietary exposure. Significant linear positive correlations in concentrations of syn-Dechlorane Plus (DP) and anti-DP were found between soils and those in co-located chicken samples (p e-waste processing sites and non-e-waste processing areas elsewhere.

  15. Data Validation Package September 2016 Groundwater and Surface Water Sampling at the Slick Rock, Colorado, Processing Sites January 2017

    Energy Technology Data Exchange (ETDEWEB)

    Traub, David [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States); Nguyen, Jason [US Department of Energy, Washington, DC (United States)

    2017-01-04

    The Slick Rock, Colorado, Processing Sites are referred to as the Slick Rock West Processing Site (SRK05) and the Slick Rock East Processing Site (SRK06). This annual event involved sampling both sites for a total of 16 monitoring wells and 6 surface water locations as required by the 2006 Draft Final Ground Water Compliance Action Plan for the Slick Rock, Colorado, Processing Sites (GCAP). A domestic well was also sampled at a property adjacent to the Slick Rock East site at the request of the landowner.

  16. A simple, robust lightweight microscopy and sample processing system for scientific and commercial research on ISS Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A light-weight, user-friendly, algorithmically or remotely controlled microscope, not purchased from a microscope company, coupled to fluid sample processing and...

  17. Raman Spectroscopy of cultural heritage Materials: Overview of Applications and New Frontiers in Instrumentation, Sampling Modalities, and Data Processing.

    Science.gov (United States)

    Casadio, Francesca; Daher, Céline; Bellot-Gurlet, Ludovic

    2016-10-01

    Rooted in the long tradition of Raman spectroscopy of cultural heritage materials, in this work we provide a personal perspective on recent applications and new frontiers in sampling modalities, data processing, and instrumentation.

  18. Sealed magic angle spinning nuclear magnetic resonance probe and process for spectroscopy of hazardous samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Herman M.; Washton, Nancy M.; Mueller, Karl T.; Sears, Jr., Jesse A.; Townsend, Mark R.; Ewing, James R.

    2016-06-14

    A magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) probe is described that includes double containment enclosures configured to seal and contain hazardous samples for analysis. The probe is of a modular design that ensures containment of hazardous samples during sample analysis while preserving spin speeds for superior NMR performance and convenience of operation.

  19. Review of Worcestershire On-line Fabric Type Series website

    Directory of Open Access Journals (Sweden)

    Beverley Nenk

    2003-06-01

    Full Text Available The study of archaeological ceramics is advanced through the creation and development of regional and national pottery type-series, which contain samples of each type of pottery identified from a particular area or region. Pottery researchers working in any period, from prehistoric to post-medieval, require access to such type-series, and to their associated data, in order to be able to advance the identification of all types of pottery, not only those types produced in the local area, but those produced in surrounding regions, as well as those imported from abroad. The publication of such type-series, as well as their accessibility to researchers, is essential if the information they contain is to be disseminated. The development of the Worcestershire On-Line Fabric Type Series is the first stage in a remarkable project designed to make the complete fabric and form type series for Worcestershire ceramics accessible on the internet. As part of the Historic Environment Record for Worcestershire, formerly the Sites and Monuments Record, it is designed to improve access to finds and environmental data, with the aim of encouraging and facilitating research. Funded by Worcestershire County Council as part of its commitment to e-government, it is being developed by Worcestershire County Council Archaeology Service with OxfordArchDigital. It is one of a proposed series of on-line specialist resources (to include, for example, clay pipes, environmental archaeology, flint tools, historic buildings, which are also designed to stand alone as research tools. The ceramics website is the first part of Pottery in Perspective, a web-based project to provide information on the pottery used and made in Worcestershire from prehistory to c. 1900AD.

  20. DOE-EPRI On-Line Monitoring Implementation Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    E. Davis, R. Bickford

    2003-01-02

    Industry and EPRI experience at several plants has shown on-line monitoring to be very effective in identifying out-of-calibration instrument channels or indications of equipment-degradation problems. The EPRI implementation project for on-line monitoring has demonstrated the feasability of on-line monitoring at several participating nuclear plants. The results have been very enouraging, and substantial progress is anticipated in the coming years.