WorldWideScience

Sample records for on-line sample pretreatment

  1. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in ...

  2. Development of on-line electrochemical sample pretreatment methods for the analysis of thallium and uranium by ICP-MS

    International Nuclear Information System (INIS)

    Zhou, F.; Van Berkel, G.J.; Morton, S.J.; Duckworth, D.C.; Adeniyi, W.K.; Keller, J.M.

    1995-01-01

    Anodic and adsorptive stripping voltammetry (AWV and AdSV, respectively) were performed on-line with a mercury thin-film electrode (MTFE) to effect the selective accumulation and detection of thallium and uranium, respectively. ASV-ICP-MS experiments using thallium as the test element were performed to characterize the behavior of the on-line system for low level and quantitative determinations. Excellent linearity in response was demonstrated for thallium standards ranging from 0.25 ng/L to 50 microg/L. The 1.0 pg/L detection limit calculated from this data for thallium (3σ/sensitivity) was 400 times lower than that of conventional ICP-MS. The ability to overcome sample matrix effects in quantitative determinations was demonstrated by the analysis of an undiluted synthetic urine sample. AdSV-ICP-MS experiments were performed using uranium as the test element to demonstrate the utility of this method for the determination of radiologically important elements. A uranium(VI)-cupferron complex was used to effect adsorptive accumulation of uranium from a 10 microg/L standard solution onto the MTFE. The uranium was chemically stripped from the electrode for subsequent downstream detection by the ICP-MS. The quantitative nature of this method and a modest enhancement of signal levels (∼X10) over those levels obtained with conventional ICP-MS for samples in the microgram/liter concentration range were demonstrated. Modifications to the current system to provide low flow rate operation will allow further optimization of the ASV-ICP-MS and AdSV-ICP-MS combinations

  3. An integrated sample pretreatment platform for quantitative N-glycoproteome analysis with combination of on-line glycopeptide enrichment, deglycosylation and dimethyl labeling

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Yejing; Qu, Yanyan; Jiang, Hao; Wu, Qi [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Zhang, Lihua, E-mail: lihuazhang@dicp.ac.cn [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); Yuan, Huiming [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); Zhou, Yuan [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Zhang, Xiaodan; Zhang, Yukui [National Chromatographic Research and Analysis Center, Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China)

    2014-06-23

    Highlights: • An integrated platform for quantitative N-glycoproteome analysis was established. • On-line enrichment, deglycosylation and labeling could be achieved within 160 min. • A N{sub 2}-assisted interface was applied to improve the compatibility of the platform. • The platform exhibited improved quantification accuracy, precision and throughput. - Abstract: Relative quantification of N-glycoproteomes shows great promise for the discovery of candidate biomarkers and therapeutic targets. The traditional protocol for quantitative analysis of glycoproteomes is usually off-line performed, and suffers from long sample preparation time, and the risk of sample loss or contamination due to manual manipulation. In this study, a novel integrated sample preparation platform for quantitative N-glycoproteome analysis was established, with combination of online N-glycopeptide capture by a HILIC column, sample buffer exchange by a N{sub 2}-assisted HILIC–RPLC interface, deglycosylation by a hydrophilic PNGase F immobilized enzymatic reactor (hIMER) and solid dimethyl labeling on a C18 precolumn. To evaluate the performance of such a platform, two equal aliquots of immunoglobulin G (IgG) digests were sequentially pretreated, followed by MALDI-TOF MS analysis. The signal intensity ratio of heavy/light (H/L) labeled deglycosylated peptides with the equal aliquots was 1.00 (RSD = 6.2%, n = 3), much better than those obtained by the offline protocol, with H/L ratio as 0.76 (RSD = 11.6%, n = 3). Additionally, the total on-line sample preparation time was greatly shortened to 160 min, much faster than that of offline approach (24 h). Furthermore, such an integrated pretreatment platform was successfully applied to analyze the two kinds of hepatocarcinoma ascites syngeneic cell lines with high (Hca-F) and low (Hca-P) lymph node metastasis rates. For H/L labeled Hca-P lysates with the equal aliquots, 99.6% of log 2 ratios (H/L) of quantified glycopeptides ranged from −1

  4. On-line sample treatment - Capillary gas chromatography

    NARCIS (Netherlands)

    Goosens, EC; de Jong, D; de Jong, GJ; Brinkman, UAT

    Sample pretreatment is often the bottleneck of a trace level analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of

  5. On-line sample processing methods in flow analysis

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2008-01-01

    In this chapter, the state of the art of flow injection and related approaches thereof for automation and miniaturization of sample processing regardless of the aggregate state of the sample medium is overviewed. The potential of the various generation of flow injection for implementation of in...

  6. Critical evaluation of sample pretreatment techniques.

    Science.gov (United States)

    Hyötyläinen, Tuulia

    2009-06-01

    Sample preparation before chromatographic separation is the most time-consuming and error-prone part of the analytical procedure. Therefore, selecting and optimizing an appropriate sample preparation scheme is a key factor in the final success of the analysis, and the judicious choice of an appropriate procedure greatly influences the reliability and accuracy of a given analysis. The main objective of this review is to critically evaluate the applicability, disadvantages, and advantages of various sample preparation techniques. Particular emphasis is placed on extraction techniques suitable for both liquid and solid samples.

  7. On-line determination of manganese in solid seafood samples by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Yebra, M.C.; Moreno-Cid, A.

    2003-01-01

    Manganese is extracted on-line from solid seafood samples by a simple continuous ultrasound-assisted extraction system (CUES). This system is connected to an on-line manifold, which permits the flow-injection flame atomic absorption spectrometric determination of manganese. Optimisation of the continuous leaching procedure is performed by an experimental design. The proposed method allows the determination of manganese with a relative standard deviation of 0.9% for a sample containing 23.4 μg g -1 manganese (dry mass). The detection limit is 0.4 μg g -1 (dry mass) for 30 mg of sample and the sample throughput is ca. 60 samples per hour. Accurate results are obtained by measuring TORT-1 certified reference material. The procedure is finally applied to mussel, tuna, sardine and clams samples

  8. [DNA quantification of blood samples pre-treated with pyramidon].

    Science.gov (United States)

    Zhu, Chuan-Hong; Zheng, Dao-Li; Ni, Rao-Zhi; Wang, Hai-Sheng; Ning, Ping; Fang, Hui; Liu, Yan

    2014-06-01

    To study DNA quantification and STR typing of samples pre-treated with pyramidon. The blood samples of ten unrelated individuals were anticoagulated in EDTA. The blood stains were made on the filter paper. The experimental groups were divided into six groups in accordance with the storage time, 30 min, 1 h, 3 h, 6 h, 12 h and 24h after pre-treated with pyramidon. DNA was extracted by three methods: magnetic bead-based extraction, QIAcube DNA purification method and Chelex-100 method. The quantification of DNA was made by fluorescent quantitative PCR. STR typing was detected by PCR-STR fluorescent technology. In the same DNA extraction method, the sample DNA decreased gradually with times after pre-treatment with pyramidon. In the same storage time, the DNA quantification in different extraction methods had significant differences. Sixteen loci DNA typing were detected in 90.56% of samples. Pyramidon pre-treatment could cause DNA degradation, but effective STR typing can be achieved within 24 h. The magnetic bead-based extraction is the best method for STR profiling and DNA extraction.

  9. Automatic data acquisition and on-line analysis of trace element concentration in serum samples

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.

    1978-01-01

    A completely automated system has been developed to determine the trace element concentration in biological samples by measuring charged particle induced X-rays. A CDC-3100 computer with ADC and CAMAC interface is employed to control the data collection apparatus, acquire data and perform simultaneously the analysis. The experimental set-up consists of a large square plexiglass chamber in which a commercially available 750H Kodak Carousel is suitably arranged as a computer controlled sample changer. A method of extracting trace element concentrations using reference spectra is presented and an on-line program has been developed to easily and conveniently obtain final results at the end of each run. (Auth.)

  10. On-line Automated Sample Preparation-Capillary Gas Chromatography for the Analysis of Plasma Samples.

    NARCIS (Netherlands)

    Louter, A.J.H.; van der Wagt, R.A.C.A.; Brinkman, U.A.T.

    1995-01-01

    An automated sample preparation module, (the automated sample preparation with extraction columns, ASPEC), was interfaced with a capillary gas chromatograph (GC) by means of an on-column interface. The system was optimised for the determination of the antidepressant trazodone in plasma. The clean-up

  11. A system for on-line monitoring of light element concentration distributions in thin samples

    Energy Technology Data Exchange (ETDEWEB)

    Brands, P.J.M. E-mail: p.j.m.brands@tue.nl; Mutsaers, P.H.A.; Voigt, M.J.A. de

    1999-09-02

    At the Cyclotron Laboratory, a scanning proton microprobe is used to determine concentration distributions in biomedical samples. The data acquired in these measurements used to be analysed in a time consuming off-line analysis. To avoid the loss of valuable measurement and analysis time, DYANA was developed. DYANA is an on-line method for the analysis of data from biomedical measurements. By using a database of background shapes, light elements such as Na and Mg, can be fitted even more precisely than in conventional fitting procedures. The entire analysis takes only several seconds and is performed while the acquisition system is gathering a new subset of data. Data acquisition must be guaranteed and may not be interfered by other parallel processes. Therefore, the analysis, the data acquisition and the experiment control is performed on a PCI-based Pentium personal computer (PC), running a real-time operating system. A second PC is added to run a graphical user interface for interaction with the experimenter and the monitoring of the analysed results. The system is here illustrated using atherosclerotic tissue but is applicable to all kinds of thin samples.

  12. Automation and integration of multiplexed on-line sample preparation with capillary electrophoresis for DNA sequencing

    Energy Technology Data Exchange (ETDEWEB)

    Tan, H.

    1999-03-31

    The purpose of this research is to develop a multiplexed sample processing system in conjunction with multiplexed capillary electrophoresis for high-throughput DNA sequencing. The concept from DNA template to called bases was first demonstrated with a manually operated single capillary system. Later, an automated microfluidic system with 8 channels based on the same principle was successfully constructed. The instrument automatically processes 8 templates through reaction, purification, denaturation, pre-concentration, injection, separation and detection in a parallel fashion. A multiplexed freeze/thaw switching principle and a distribution network were implemented to manage flow direction and sample transportation. Dye-labeled terminator cycle-sequencing reactions are performed in an 8-capillary array in a hot air thermal cycler. Subsequently, the sequencing ladders are directly loaded into a corresponding size-exclusion chromatographic column operated at {approximately} 60 C for purification. On-line denaturation and stacking injection for capillary electrophoresis is simultaneously accomplished at a cross assembly set at {approximately} 70 C. Not only the separation capillary array but also the reaction capillary array and purification columns can be regenerated after every run. DNA sequencing data from this system allow base calling up to 460 bases with accuracy of 98%.

  13. On-line combination of liquid chromatography and capillary gas chromatography : preconcentration and analysis of organic compounds in aqueous samples

    NARCIS (Netherlands)

    Noij, T.H.M.; Weiss, E.; Herps, T.; Cruchten, van H.; Rijks, J.A.

    1988-01-01

    This paper describes the design of a new, versatile, and low-cost on-line LC-GC interface that allows the fast and reliable introduction of large sample volumes onto a capillary GC column. The sample introduction procedure consists successively of: evaporation of the entire sample (LC fraction),

  14. Advances in paper-based sample pretreatment for point-of-care testing.

    Science.gov (United States)

    Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng

    2017-06-01

    In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.

  15. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K [Oulu Univ. (Finland)

    1999-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  16. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K. [Oulu Univ. (Finland)

    1998-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  17. Design development of robotic system for on line sampling in fuel reprocessing

    International Nuclear Information System (INIS)

    Balasubramanian, G.R.; Venugopal, P.R.; Padmashali, G.K.

    1990-01-01

    This presentation describes the design and developmental work that is being carried out for the design of an automated sampling system for fast reactor fuel reprocessing plants. The plant proposes to use integrated sampling system. The sample is taken across regular process streams from any intermediate hold up pot. A robot system is planned to take the sample from the sample pot, transfer it to the sample bottle, cap the bottle and transfer the bottle to a pneumatic conveying station. The system covers a large number of sample pots. Alternate automated systems are also examined (1). (author). 4 refs., 2 figs

  18. 7 CFR 42.143 - Operating Characteristic (OC) curves for on-line sampling and inspection.

    Science.gov (United States)

    2010-01-01

    ...=Number of sample units in a subgroup. T=Subgroup tolerance.L=Acceptance limit.S=Starting value. EC02SE91... ng=Number of sample units in a subgroup. T=Subgroup tolerance. L=Acceptance limit. S=Starting value... of sample units in a subgroup. T=Subgroup tolerance. L=Acceptance limit. S=Starting value. EC02SE91...

  19. A system for on-line monitoring of light element concentration distributions in thin samples

    NARCIS (Netherlands)

    Brands, P.J.M.; Mutsaers, P.H.A.; Voigt, de M.J.A.

    1999-01-01

    At the Cyclotron Laboratory, a scanning proton microprobe is used to determine concentration distributions in biomedical samples. The data acquired in these measurements used to be analysed in a time consuming off-line analysis. To avoid the loss of valuable measurement and analysis time, DYANA was

  20. Using mark-recapture distance sampling methods on line transect surveys

    Science.gov (United States)

    Burt, Louise M.; Borchers, David L.; Jenkins, Kurt J.; Marques, Tigao A

    2014-01-01

    Mark–recapture distance sampling (MRDS) methods are widely used for density and abundance estimation when the conventional DS assumption of certain detection at distance zero fails, as they allow detection at distance zero to be estimated and incorporated into the overall probability of detection to better estimate density and abundance. However, incorporating MR data in DS models raises survey and analysis issues not present in conventional DS. Conversely, incorporating DS assumptions in MR models raises issues not present in conventional MR. As a result, being familiar with either conventional DS methods or conventional MR methods does not on its own put practitioners in good a position to apply MRDS methods appropriately. This study explains the sometimes subtly different varieties of MRDS survey methods and the associated concepts underlying MRDS models. This is done as far as possible without giving mathematical details – in the hope that this will make the key concepts underlying the methods accessible to a wider audience than if we were to present the concepts via equations.

  1. Determination of drugs in biological fluids by high-performance liquid chromatography with on-line sample processing.

    Science.gov (United States)

    Oertel, R; Richter, K; Gramatté, T; Kirch, W

    1998-02-27

    An automated two column HPLC system with the new packing material LiChrospher RP-18 ADS (alkyl-diol-silica) was tested for the determination of several drugs and metabolites (talinolol, celiprolol, metoprolol, oxprenolol, triamterene, trimethoprim, tiracizine, articaine, detajmium, ajmaline, lamotrigine) in various biological fluids (serum, urine, intestinal aspirates, supernatants of cell cultures and supernatants after protein denaturation). The method allows the direct injection of biological fluids into a reversed-phase HPLC system and on-line clean-up and sample enrichment by a column-switching technique. Precision, accuracy and sensitivity were similar to conventional assays as described in the literature. With this new method it was possible to measure drug concentrations in various biological fluids without changing the sample preparation procedure. In some cases an additional sample preparation like protein denaturation or solid-phase extraction was advantageous to enhance the sensitivity of the method and the life-time of the ADS column.

  2. Recent developments in sample preparation and data pre-treatment in metabonomics research.

    Science.gov (United States)

    Li, Ning; Song, Yi peng; Tang, Huiru; Wang, Yulan

    2016-01-01

    Metabonomics is a powerful approach for biomarker discovery and an effective tool for pinpointing endpoint metabolic effects of external stimuli, such as pathogens and disease development. Due to its wide applications, metabonomics is required to deal with various biological samples of different properties. Hence sample preparation and corresponding data pre-treatment become important factors in ensuring validity of an investigation. In this review, we summarize some recent developments in metabonomics sample preparation and data-pretreatment procedures. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Analysis of plant hormones by microemulsion electrokinetic capillary chromatography coupled with on-line large volume sample stacking.

    Science.gov (United States)

    Chen, Zongbao; Lin, Zian; Zhang, Lin; Cai, Yan; Zhang, Lan

    2012-04-07

    A novel method of microemulsion electrokinetic capillary chromatography (MEEKC) coupled with on-line large volume sample stacking was developed for the analysis of six plant hormones including indole-3-acetic acid, indole-3-butyric acid, indole-3-propionic acid, 1-naphthaleneacetic acid, abscisic acid and salicylic acid. Baseline separation of six plant hormones was achieved within 10 min by using the microemulsion background electrolyte containing a 97.2% (w/w) 10 mM borate buffer at pH 9.2, 1.0% (w/w) ethyl acetate as oil droplets, 0.6% (w/w) sodium dodecyl sulphate as surfactant and 1.2% (w/w) 1-butanol as cosurfactant. In addition, an on-line concentration method based on a large volume sample stacking technique and multiple wavelength detection was adopted for improving the detection sensitivity in order to determine trace level hormones in a real sample. The optimal method provided about 50-100 fold increase in detection sensitivity compared with a single MEEKC method, and the detection limits (S/N = 3) were between 0.005 and 0.02 μg mL(-1). The proposed method was simple, rapid and sensitive and could be applied to the determination of six plant hormones in spiked water samples, tobacco leaves and 1-naphthylacetic acid in leaf fertilizer. The recoveries ranged from 76.0% to 119.1%, and good reproducibilities were obtained with relative standard deviations (RSDs) less than 6.6%.

  4. Determination of total and inorganic mercury in fish samples with on-line oxidation coupled to atomic fluorescence spectrometry

    International Nuclear Information System (INIS)

    Shao Lijun; Gan Wuer; Su Qingde

    2006-01-01

    An atomic fluorescence spectrometry system for determination of total and inorganic mercury with electromagnetic induction-assisted heating on-line oxidation has been developed. Potassium peroxodisulphate was used as the oxidizing agent to decompose organomercury compounds. Depending on the temperature selected, inorganic or total mercury could be determined with the same manifold. Special accent was put on the study of the parameters influencing the on-line digestion efficiency. The tolerance to the interference of coexisting ions was carefully examined in this system. Under optimal conditions, the detection limits (3σ) were evaluated to be 2.9 ng l -1 for inorganic mercury and 2.6 ng l -1 for total mercury, respectively. The relative standard deviations for 10 replicate determinations of 1.0 μg l -1 Hg were 2.4 and 3.2% for inorganic mercury and total mercury, respectively. The proposed method was successfully applied to the determination of total and inorganic mercury in fish samples

  5. On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample.

    Science.gov (United States)

    Zhang, Xiuli; Martens, Dieter; Krämer, Petra M; Kettrup, Antonius A; Liang, Xinmiao

    2006-11-10

    An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.

  6. Determination of trace thorium in water samples by flow injection fluorescence spectrophotometry with microcolumn on-line preconcentration

    International Nuclear Information System (INIS)

    Shen Zhuqin; Zhang Yanan; Guo Dongfa; Huang Yun

    1991-01-01

    An on-line preconcentration time resolved fluorimetric method was developed for the determination of trace thorium in water, based on luminescence of complex Th-morin-TOPO (or TRPO)-sodium lauryl sulfate in sulfuric acid medium. Interferences from companied cations, such as Al 3+ and Zr 4+ , which emit fluorescence with much slower rising rate at the same condition were effectively eliminated through optimization of the manifold parameters and precisely controlling of the elution flow rate. Effects of nearly 40 ions were also investigated. The detection limit, the liner range and relative standard deviation for 50 ng Th are 2.5 ng/L, 0∼80 ng and 3.6%, respectively. Sampling rate is 30 per hour

  7. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, Mirna, E-mail: msigrist@fiq.unl.edu.ar [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Albertengo, Antonela; Beldomenico, Horacio [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Tudino, Mabel [Laboratorio de Analisis de Trazas, Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE, Facultad de Ciencias Exactas y Naturales, Pabellon II, Ciudad Universitaria (1428), Buenos Aires (Argentina)

    2011-04-15

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH{sub 3} generation using 3.5 mol L{sup -1} HCl as carrier solution and 0.35% (m/v) NaBH{sub 4} in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, HPO{sub 4}{sup 2-}, HCO{sub 3}{sup -} on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C{sub 6}H{sub 8}O{sub 6} solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 {mu}g L{sup -1} and 0.6 {mu}g L{sup -1} for As(III) and inorganic total As, respectively, were obtained for a 500 {mu}L sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h{sup -1}. The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species

  8. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Sigrist, Mirna; Albertengo, Antonela; Beldomenico, Horacio; Tudino, Mabel

    2011-01-01

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH 3 generation using 3.5 mol L -1 HCl as carrier solution and 0.35% (m/v) NaBH 4 in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl - , SO 4 2- , NO 3 - , HPO 4 2- , HCO 3 - on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C 6 H 8 O 6 solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 μg L -1 and 0.6 μg L -1 for As(III) and inorganic total As, respectively, were obtained for a 500 μL sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h -1 . The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species separation was performed through the employ of a serial connection of membrane filters and

  9. [Analysis of phthalate esters in plastic-packaging bags on-line sample stacking-microemulsion electrokinetic chromatography].

    Science.gov (United States)

    Xiao, Jia; Huang, Ying; Wang, Minyi; Chen, Guonan

    2012-09-01

    Two convenient, effective, and reproducible methods using microemulsion electrokinetic chromatography (MEEKC)-normal stacking mode (NSM) and reversed electrode polarity stacking mode (REPSM) were developed for the on-line sample stacking of phthalate esters (PAEs). REPSM coupled with MEEKC increased the sensitivity of 937.5 to 7,143 times for four PAEs compared to the conventional MEEKC. The separating conditions in the MEEKC method were studied, and many factors influencing the two sample stacking processes were investigated in detail. The optimum sample matrices for the two stacking methods were as follows: 30 mmol/L sodium cholate (SC) and 30.0 mmol/L borate (pH 8.5). Additionally, sample injections as large as 3.45 kPa x 40 s and 3.45 kPa x 90 s were applied for NSM-MEEKC and REPSM-MEEKC, respectively. The linear relationship and reproducibility were also examined. Under the optimum conditions, the detection limits (S/N = 3) of the PAEs were in the ranges of 0.021 - 0.33 mg/L and 0.7 - 4 microg/L for NSM-MEEKC and REPSM-MEEKC, respectively. The proposed REPSM-MEEKC has been successfully applied to determine PAEs in plastic-packaging bags, and the spiked recoveries were in the range of 89.1% - 105.6% with satisfactory results.

  10. On-line preconcentration and determination of mercury in biological and environmental samples by cold vapor-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Ferrua, N.; Cerutti, S.; Salonia, J.A.; Olsina, R.A.; Martinez, L.D.

    2007-01-01

    An on-line procedure for the determination of traces of total mercury in environmental and biological samples is described. The present methodology combines cold vapor generation associated to atomic absorption spectrometry (CV-AAS) with preconcentration of the analyte on a minicolumn packed with activated carbon. The retained analyte was quantitatively eluted from the minicolumn with nitric acid. After that, volatile specie of mercury was generated by merging the acidified sample and sodium tetrahydroborate(III) in a continuous flow system. The gaseous analyte was subsequently introduced via a stream of Ar carrier into the atomizer device. Optimizations of both, preconcentration and mercury volatile specie generation variables were carried out using two level full factorial design (2 3 ) with 3 replicates of the central point. Considering a sample consumption of 25 mL, an enrichment factor of 13-fold was obtained. The detection limit (3σ) was 10 ng L -1 and the precision (relative standard deviation) was 3.1% (n = 10) at the 5 μg L -1 level. The calibration curve using the preconcentration system for mercury was linear with a correlation coefficient of 0.9995 at levels near the detection limit up to at least 1000 μg L -1 . Satisfactory results were obtained for the analysis of mercury in tap water and hair samples

  11. On-line technique for preparingand measuring stable carbon isotopeof total dissolved inorganic carbonin water samples ( d13CTDIC

    Directory of Open Access Journals (Sweden)

    S. Inguaggiato

    2005-06-01

    Full Text Available A fast and completely automated procedure is proposed for the preparation and determination of d13C of total inorganic carbon dissolved in water ( d13CTDIC. This method is based on the acidification of water samples transforming the whole dissolved inorganic carbon species into CO2. Water samples are directly injected by syringe into 5.9 ml vials with screw caps which have a pierciable rubber septum. An Analytical Precision «Carbonate Prep System» was used both to flush pure helium into the vials and to automatically dispense a fixed amount of H3PO4. Full-equilibrium conditions between produced CO2 and water are reached at a temperature of 70°C (± 0.1°C in less than 24 h. Carbon isotope ratios (13C/ 12C were measured on an AP 2003 continuous flow mass spectrometer, connected on-line with the injection system. The precision and reproducibility of the proposed method was tested both on aqueous standard solutions prepared using Na2CO3 with d13C=-10.78 per mil versus PDB (1 s= 0.08, n = 11, and at five different concentrations (2, 3, 4, 5 and 20 mmol/l and on more than thirty natural samples. Mean d13CTDIC on standard solution samples is ?10.89 < per mil versus PDB (1 s= 0.18, n = 50, thus revealing both a good analytical precision and reproducibility. A comparison between average d13CTDIC values on a quadruplicate set of natural samples and those obtained following the chemical and physical stripping method highlights a good agreement between the two analytical methods.

  12. Effect of sample pre-treatment on the determination of steroid esters in hair of bovine calves

    NARCIS (Netherlands)

    Aqai, P.; Stolker, A.A.M.; Lasaroms, J.J.P.

    2009-01-01

    The effect of three sample pre-treatment steps, washing, cutting and grinding on the determination of steroid esters in hair is studied. The study is performed by using hair samples obtained after pour-on application of steroid esters to bovine calves. After sample pre-treatment the hair is treated

  13. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples

    Science.gov (United States)

    Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent

    2017-01-01

    A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE “acetonitrile stacking” preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L−1 and 2.91 and 3.86 µg∙L−1, respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers. PMID:28686186

  14. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples

    Directory of Open Access Journals (Sweden)

    Maria Espina-Benitez

    2017-07-01

    Full Text Available A new analytical method coupling a (off-line solid-phase microextraction with an on-line capillary electrophoresis (CE sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE using ultraviolet diode array detection (DAD. Further enhancement of concentration sensitivity detection was achieved by on-line CE “acetonitrile stacking” preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L−1 and 2.91 and 3.86 µg∙L−1, respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers.

  15. Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples.

    Science.gov (United States)

    Espina-Benitez, Maria; Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent

    2017-07-07

    A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE "acetonitrile stacking" preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L -1 and 2.91 and 3.86 µg∙L -1 , respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers.

  16. On-line coupling of sample preconcentration by LVSEP with gel electrophoretic separation on T-channel chips.

    Science.gov (United States)

    Kitagawa, Fumihiko; Kinami, Saeko; Takegawa, Yuuki; Nukatsuka, Isoshi; Sueyoshi, Kenji; Kawai, Takayuki; Otsuka, Koji

    2017-01-01

    To achieve an on-line coupling of the sample preconcentration by a large-volume sample stacking with an electroosmotic flow pump (LVSEP) with microchip gel electrophoresis (MCGE), a sample solution, a background solution for LVSEP and a sieving solution for MCGE were loaded in a T-form channel and three reservoirs on PDMS microchips. By utilizing the difference in the flow resistance of the two channels, a low-viscosity sample and a viscous polymer solution were easily introduced into the LVSEP and MCGE channels, respectively. Fluorescence imaging of the sequential LVSEP-MCGE processes clearly demonstrated that a faster stacking of anionic fluorescein and successive introduction into the MCGE channel can be carried out on the T-channel chip. To evaluate the preconcentration performance, a conventional MCZE analysis of fluorescein on the cross-channel chip was compared with LVSEP-MCGE on the short T-channel chip, and as a result that the value of sensitive enhancement factor (SEF) was estimated to be 370. The repeatability of the peak height was good with the RSD value of 3.2%, indicating the robustness of the enrichment performance. In the successive LVSEP-MCGE analysis of φX174/HaeIII digest, the DNA fragments were well enriched to a sharp peak in the LVSEP channel, and they were separated in the MCGE channel, whose electropherogram was well-resembled with that in the conventional MCGE. The values of SEF for the DNA fragments were calculated to be ranging from 74 to 108. Thus, the successive LVSEP-MCGE analysis was effective for both preconcentrating and separating DNA fragments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Flow injection on-line oxidizing fluorometry coupled to dialysis sampling for the study of carbamazepine-protein binding

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Zhiqi [School of Chemistry and Materials Science, Shaanxi Normal University, Xi' an 710062 (China)]. E-mail: zqzhang@snnu.edu.cn; Liang Guoxi [School of Chemistry and Materials Science, Shaanxi Normal University, Xi' an 710062 (China)

    2005-04-22

    The mechanism of binding of carbamazepine (CBZ) with bovine serum albumin (BSA) has been investigated in vitro based on a new flow injection fluorometry coupled to the technique of dialysis sampling. The CBZ and BSA were mixed in different molar ratios in 0.050 mol L{sup -1} phosphate buffer (containing 0.9% NaCl), pH 7.4, and incubated at 37 {+-} 0.5 deg. C in a water bath. The dialysis sampler was utilized to sample free CBZ from mixed solution with a relative dialytic efficiency of 7.6%. Then the CBZ in dialysis solution was injected into carrier and on-line oxidized by lead dioxide solid-phase reactor into fluorescent product with a maximum excitation wavelength of 355 nm and a maximum emission wavelength of 478 nm. The fluorescence intensity measured was linear proportional with the concentration of free CBZ in mixed solution over the range of 1 x 10{sup -5} to 2 x 10{sup -4} mol L{sup -1} with the detection limit of 6 x 10{sup -6} mol L{sup -1}. According to the fluorescence measurement results from mixed solution, the association constant (K) estimated for CBZ-BSA binding and the number of the binding site (n) with Scatchard analysis were 1.08 x 10{sup 4} L mol{sup -1} and 0.94, respectively. Stern-Volmer plots indicated the presence of dynamic component in the quenching mechanism. The acting force was suggested to be mainly hydrophobic and the distance between the acceptor and donor was 3.12 nm. The estimated binding parameters agreed well with literature values.

  18. Evaluation of sample pretreatment methods for analysis of polonium isotopes in herbal medicines

    International Nuclear Information System (INIS)

    Sreejith, Sathyapriya R.; Nair, Madhu G.; Rao, D.D.

    2014-01-01

    Herbal infusions like ayurvedic aristas are widely consumed by Indian population for good health. With increasing awareness about radiological assessment, an effort was made to assess the radioactivity concentration of naturally occurring radionuclides in herbal medicines. 210 Po is an important alpha particle emitter contributing to internal dose to man from ingestion. Though 210 Po can be spontaneously deposited on silver disk for alpha spectrometric measurements with less radiochemical step, great care has to be taken during the sample pretreatment step owing to the high volatility of polonium even at low temperatures. Aim of the study was to evaluate an appropriate sample pretreatment method for estimation of polonium in herbal medicines. 209 Po was used for radiochemical yield calculation. Conventional open vessel wet ashing, physical evaporation, freeze-drying and microwave digestion in a Teflon vessel were examined. The recovery ranged between 9 and 79%. The lowest recovery was obtained for the samples that were processed by open vessel digestion without any volume reduction. The recoveries were comparable for those samples that were freeze dried and subjected to HNO 3 + HClO 4 + H 2 O 2 + HF acid digestion and microwave digested samples. 210 Po concentration in the samples ranged from 11.3 to 39.6 mBq/L

  19. Analysis of microcontaminants in aqueous samples by fully automated on-line solid-phase extraction-gas chromatography-mass selective detection.

    NARCIS (Netherlands)

    Louter, A.J.H.; van Beekvelt, C.A.; Cid Montanes, P.; Slobodník, J.; Vreuls, J.J.; Brinkman, U.A.T.

    1996-01-01

    The trace-level analysis of unknown organic pollutants in water requires the use of fast and sensitive methods which also provide structural information. In the present study, an on-line technique was used which combines sample preparation by means of solid-phase extraction (SPE) on a small

  20. Validation of a high performance liquid chromatography analysis for the determination of noradrenaline and adrenaline in human urine with an on-line sample purification

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Kristiansen, J; Nielsen, J L

    1999-01-01

    A high performance liquid chromatography (HPLC) method with fluorescence detection including an on-line purification was established for determination of catecholamines in human urine. The method was evaluated using samples of pooled urine spiked with catecholamines and validated for measurements...

  1. Sample pretreatment for the determination of metal impurities in silicon wafer

    International Nuclear Information System (INIS)

    Chung, H. Y.; Kim, Y. H.; Yoo, H. D.; Lee, S. H.

    1999-01-01

    The analytical results obtained by microwave digestion and acid digestion methods for sample pretreatment to determine metal impurities in silicon wafer by inductively coupled plasma--mass spectrometry(ICP-MS) were compared. In order to decompose the silicon wafer, a mixed solution of HNO 3 and HF was added to the sample and the metal elements were determined after removing the silicon matrix by evaporating silicon in the form of Si-F. The recovery percentages of Ni, Cr and Fe were found to be 95∼106% for both microwave digestion and acid digestion methods. The recovery percentage of Cu obtained by the acid digestion method was higher than that obtained by the microwave digestion method. For Zn, however, the microwave digestion method gave better result than the acid digestion method. Fe was added to a silicon wafer using a spin coater. The concentration of Fe in this sample was determined by ICP-MS, and the same results were obtained in the two pretreatment methods

  2. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    Science.gov (United States)

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were water without sample pretreatment.

  3. Evaluation of sample pretreatment methods for analysis of Polonium isotopes in herbal medicine

    International Nuclear Information System (INIS)

    Sathyapriya, R.S.; Nair, Madhu G.; Rao, D.D.

    2013-01-01

    Ayurvedic medicines are widely consumed by Indian population both for treatment and good health Ayurvedic medicines are used in various forms like infusions, decoctions, powder, tablets, fermented decoction (Arishta) etc. Arishtas are prepared using plant extracts soaked in sugar or jaggery and are generally consume on regular basis for good health. Hence an effort was made to analyse the natural radioactivity in the Ayurvedic Arishtas. 213 Po is an important naturally occurring radionuclide that volatilizes beyond 150℃. Hence adequate care is needed during sample pretreatment step. Both physical (freeze-drying, open vessel evaporation and microwave digestion) and chemical (digestion using various mineral acids like aqua regia, Con. HNO 3 , H 2 SO 4 and oxidizing agents like H 2 O 2 and HClO 4 ) pretreatment procedures were adopted. After the initial sample treatment polonium radionuclide was pre-concentrated using calcium phosphate co-precipitation. Calcium phosphate precipitate was dissolved in 150 ml of 0.5M HCI solution with approximately 1 g of ascorbic acid for auto deposition of Polonium on silver planchette for 3 hours at 90℃ on a rotary hot plate. The sample sources were counted in calibrated alpha spectrometer with 450 mm 2 low-back-ground PIPS detector interfaced with ECIL MCA. The spectrum analysis was done using PHAST Software. 209 Po tracer, at low levels was added to the samples for assessing the radiochemical recovery. The recovery ranged between 18-83 %. The lowest recovery was obtained for the samples that were processed by open vessel digestion with HNO 3 + HCIO 4 + H 2 O 2 . The highest recover was for those samples that were freeze dried and subjected to HNO 3 + HCIO 4 + H 2 O 2 acid digestion at 90℃ for 8 hours. 210 Po concentration in a few samples varied between 0.3-3.5 mBq/L. The paper presents the results of radiochemical recoveries for different pretreatment methods and also the 210 Po content in the ayurvedic arishtas. (author)

  4. Measurement of radioactivity in the environment - Soil - Part 2: Guidance for the selection of the sampling strategy, sampling and pre-treatment of samples

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 18589 specifies the general requirements, based on ISO 11074 and ISO/IEC 17025, for all steps in the planning (desk study and area reconnaissance) of the sampling and the preparation of samples for testing. It includes the selection of the sampling strategy, the outline of the sampling plan, the presentation of general sampling methods and equipment, as well as the methodology of the pre-treatment of samples adapted to the measurements of the activity of radionuclides in soil. This part of ISO 18589 is addressed to the people responsible for determining the radioactivity present in soil for the purpose of radiation protection. It is applicable to soil from gardens, farmland, urban or industrial sites, as well as soil not affected by human activities. This part of ISO 18589 is applicable to all laboratories regardless of the number of personnel or the range of the testing performed. When a laboratory does not undertake one or more of the activities covered by this part of ISO 18589, such as planning, sampling or testing, the corresponding requirements do not apply. Information is provided on scope, normative references, terms and definitions and symbols, principle, sampling strategy, sampling plan, sampling process, pre-treatment of samples and recorded information. Five annexes inform about selection of the sampling strategy according to the objectives and the radiological characterization of the site and sampling areas, diagram of the evolution of the sample characteristics from the sampling site to the laboratory, example of sampling plan for a site divided in three sampling areas, example of a sampling record for a single/composite sample and example for a sample record for a soil profile with soil description. A bibliography is provided

  5. Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching

    Science.gov (United States)

    Song, Q.; Putcha, L.; Harm, D. L. (Principal Investigator)

    2001-01-01

    A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.

  6. Sampling method, storage and pretreatment of sediment affect AVS concentrations with consequences for bioassay responses.

    Science.gov (United States)

    De Lange, H J; Van Griethuysen, C; Koelmans, A A

    2008-01-01

    Sediment treatment and sediment storage may alter sediment toxicity, and consequently biotic response. Purpose of our study was to combine these three aspects (treatment-toxicity-biotic response) in one integrated approach. We used Acid Volatile Sulfide (AVS) concentrations as a proxy of the disturbance of the sediment. AVS and Simultaneously Extracted Metal (SEM) concentrations were compared to bioassay responses with the freshwater benthic macroinvertebrate Asellus aquaticus. Storage conditions and sediment treatment affected AVS but not SEM levels. AVS can be used as a proxy for sediment disturbance. The best way to pretreat the sediment for use in a bioassay in order to maintain initial AVS conditions was to sample the sediment with an Ekman grab, immediately store it in a jar without headspace, and freeze it as soon as possible. In a survey using seven different sediments, bioassay responses of A. aquaticus were correlated with SEM and AVS characteristics.

  7. Anionic microemulsion to solvent stacking for on-line sample concentration of cationic analytes in capillary electrophoresis.

    Science.gov (United States)

    Kukusamude, Chunyapuk; Srijaranai, Supalax; Quirino, Joselito P

    2014-05-01

    The common SDS microemulsion (i.e. 3.3% SDS, 0.8% octane, and 6.6% butanol) and organic solvents were investigated for the stacking of cationic drugs in capillary zone electrophoresis using a low pH separation electrolyte. The sample was prepared in the acidic microemulsion and a high percentage of organic solvent was included in the electrolyte at anodic end of capillary. The stacking mechanism was similar to micelle to solvent stacking where the micelles were replaced by the microemulsion for the transport of analytes to the organic solvent rich boundary. This boundary is found between the microemulsion and anodic electrolyte. The effective electrophoretic mobility of the cations reversed from the direction of the anode in the microemulsion to the cathode in the boundary. Microemulsion to solvent stacking was successfully achieved with 40% ACN in the anodic electrolyte and hydrodynamic sample injection of 21 s at 1000 mbar (equivalent to 30% of the effective length). The sensitivity enhancement factors in terms of peak height and corrected peak area were 15 to 35 and 21 to 47, respectively. The linearity R(2) in terms of corrected peak area were >0.999. Interday precisions (%RSD, n = 6) were 3.3-4.0% for corrected peak area and 2.0-3.0% for migration time. Application to spiked real sample is also presented. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Kai-Ta; Liu, Pei-Han [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Urban, Pawel L. [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Institute of Molecular Science, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China)

    2015-09-24

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h{sup −1}). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates

  9. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    International Nuclear Information System (INIS)

    Hsieh, Kai-Ta; Liu, Pei-Han; Urban, Pawel L.

    2015-01-01

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h"−"1). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates the

  10. On-line sampling of apatite-nepheline ore using apron feeders by gamma-gamma method

    Energy Technology Data Exchange (ETDEWEB)

    Bliznyuk, G.I.

    1981-01-01

    The yield flow of an underground mine equipped with a crushing complex was investigated. /sup 241/Am source and 20x20 mm NaI(Tl) crystal were used; the lump size of apatite-nepheline ore was 200 mm, P/sub 2/O/sub 5/ content varied from 10 to 22%. The mean-square error was 1% P/sub 2/O/sub 5/ in 100-ton portions of mined ore. The method can be also applied for sampling iron, copper-nickel, and polymetallic ores.

  11. Automated on-line solid phase extraction coupled to HPLC-APCI-MS detection as a versatile tool for the analysis of phenols in water samples

    International Nuclear Information System (INIS)

    Wissiack, R.

    2001-05-01

    In this work a liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS) technique was developed for the determination of phenols and anilines in waste water samples. All relevant parameters were optimized for liquid chromatographic (LC) separation and mass spectrometric (MS) detection. Mass spectrometric detection was used in either negative ionization (NI) or positive ionization (PI) mode, which was depending on the physicochemical properties of the analyte. For screening analysis, full scan mode (SCAN) was used, while selected ion monitoring (SIM) mode of acquisition was used for maximum sensitivity. The optimal interface parameters and solvent compositions were evaluated, which mainly determined the ionization of analytes thus strongly influencing the sensitivity. The quasi-molecular ions were the most abundant signals both for phenols ([M-H]- in NI) and for anilines ([M+H]+ in PI). In general, fragmentation was hardly observed for one-ring phenols. Only fragmentation due to neutral losses of NO, HCl, NH3, CO2, CHO or CO from the functional groups were obtained via collision induced dissociation (CID) in a single quadrupole mass spectrometer. A further source of structural information was the relative intensity of positive and negative ions for one analyte: Only in the case of para-methyl substituted phenols, detection was also possible in positive ionization mode with reasonable sensitivity. In contrast to the phenols, anilines offered somewhat higher structural information due to increased fragmentation through CID, when detected in the positive ionization mode. The main goal of this work was the development of a method for the determination of US EPA priority phenols in different environmental matrices. As highest sensitivity and selectivity was required for this task, a preconcentrating step was necessary, and consequently solid phase extraction (SPE) was coupled on-line to HPLC-APCI-MS. The optimized method allowed the

  12. Sampling method, storage and pretreatment of sediment affect AVS concentrations with consequences for bioassay responses

    Energy Technology Data Exchange (ETDEWEB)

    Lange, H.J. de [Aquatic Ecology and Water Quality Management Group, Wageningen University, Wageningen University and Research Centre, P.O. Box 8080, 6700 DD, Wageningen (Netherlands); Centre for Ecosystem Studies, Alterra, Wageningen University and Research Centre, P.O. Box 47, 6700 AA, Wageningen (Netherlands)], E-mail: marieke.delange@wur.nl; Griethuysen, C. van; Koelmans, A.A. [Aquatic Ecology and Water Quality Management Group, Wageningen University, Wageningen University and Research Centre, P.O. Box 8080, 6700 DD, Wageningen (Netherlands)

    2008-01-15

    Sediment treatment and sediment storage may alter sediment toxicity, and consequently biotic response. Purpose of our study was to combine these three aspects (treatment-toxicity-biotic response) in one integrated approach. We used Acid Volatile Sulfide (AVS) concentrations as a proxy of the disturbance of the sediment. AVS and Simultaneously Extracted Metal (SEM) concentrations were compared to bioassay responses with the freshwater benthic macroinvertebrate Asellus aquaticus. Storage conditions and sediment treatment affected AVS but not SEM levels. AVS can be used as a proxy for sediment disturbance. The best way to pretreat the sediment for use in a bioassay in order to maintain initial AVS conditions was to sample the sediment with an Ekman grab, immediately store it in a jar without headspace, and freeze it as soon as possible. In a survey using seven different sediments, bioassay responses of A. aquaticus were correlated with SEM and AVS characteristics. - Change in AVS is a good proxy for sediment disturbance and combined with SEM it can be used as a suitable predictor for biotic effects of sediment contamination.

  13. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Supercritical fluid extraction as an on-line clean-up technique for determination of riboflavin vitamins in food samples by capillary electrophoresis with fluorimetric detection.

    Science.gov (United States)

    Zougagh, Mohammed; Ríos, Angel

    2008-08-01

    An automatic method for the separation and determination of riboflavin (RF) vitamins (RF, flavin mononucleotide and flavin adenine dinucleotide) in food samples (chicken liver, tablet and powder milk) is proposed. The method is based on the on-line coupling of a supercritical fluid extractor (SFE) with a continuous flow-CE system with guided optical fiber fluorimetric detection (CF-CE-FD). The whole SFE-CF-CE-FD arrangement allowed the automatic treatment of food samples (clean-up of the sample followed by the extraction of the analytes), and the direct introduction of a small volume of the extracted plug to the CE-FD system for the determination of RF vitamins. Fluorescence detection introduced an appropriated sensitivity and contributed to avoid interferences of nonfluorescent polar compounds coming from the matrix samples in the extracted plug. Electrophoretic responses were linear within the 0.05-1 microg/g range, whereas the detection limits of RF vitamins were in the 0.036-0.042 microg/g range. The proposed arrangement opens up interesting prospects for the direct determination of polar analytes in complex samples with a good throughput and high level of automation.

  15. Two-Dimensional Capillary Electrophoresis with On-Line Sample Preparation and Cyclodextrin Separation Environment for Direct Determination of Serotonin in Human Urine.

    Science.gov (United States)

    Piešťanský, Juraj; Maráková, Katarína; Mikuš, Peter

    2017-10-07

    An advanced two-dimensional capillary electrophoresis method, based on on-line combination of capillary isotachophoresis and capillary zone electrophoresis with cyclodextrin additive in background electrolyte, was developed for effective determination of serotonin in human urine. Hydrodynamically closed separation system and large bore capillaries (300-800 µm) were chosen for the possibility to enhance the sample load capacity, and, by that, to decrease limit of detection. Isotachophoresis served for the sample preseparation, defined elimination of sample matrix constituents (sample clean up), and preconcentration of the analyte. Cyclodextrin separation environment enhanced separation selectivity of capillary zone electrophoresis. In this way, serotonin could be successfully separated from the rest of the sample matrix constituents migrating in capillary zone electrophoresis step so that human urine could be directly (i.e., without any external sample preparation) injected into the analyzer. The proposed method was successfully validated, showing favorable parameters of sensitivity (limit of detection for serotonin was 2.32 ng·mL -1 ), linearity (regression coefficient higher than 0.99), precision (repeatability of the migration time and peak area were in the range of 0.02-1.17% and 5.25-7.88%, respectively), and recovery (ranging in the interval of 90.0-93.6%). The developed method was applied for the assay of the human urine samples obtained from healthy volunteers. The determined concentrations of serotonin in such samples were in the range of 12.4-491.2 ng·mL -1 that was in good agreement with literature data. This advanced method represents a highly effective, reliable, and low-cost alternative for the routine determination of serotonin as a biomarker in human urine.

  16. Accelerated solvent extraction followed by on-line solid-phase extraction coupled to ion trap LC/MS/MS for analysis of benzalkonium chlorides in sediment samples

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2002-01-01

    Benzalkonium chlorides (BACs) were successfully extracted from sediment samples using a new methodology based on accelerated solvent extraction (ASE) followed by an on-line cleanup step. The BACs were detected by liquid chromatography/ion trap mass spectrometry (LC/MS) or tandem mass spectrometry (MS/MS) using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the high sensitivity offered by the ion trap MS/MS. The effects of solvent type and ASE operational variables, such as temperature and pressure, were evaluated. After optimization, a mixture of acetonitrile/water (6:4 or 7:3) was found to be most efficient for extracting BACs from the sediment samples. Extraction recoveries ranged from 95 to 105% for C12 and C14 homologues, respectively. Total method recoveries from fortified sediment samples, using a cleanup step followed by ASE, were 85% for C12BAC and 79% for C14-BAC. The methodology developed in this work provides detection limits in the subnanogram per gram range. Concentrations of BAC homologues ranged from 22 to 206 ??g/kg in sediment samples from different river sites downstream from wastewater treatment plants. The high affinity of BACs for soil suggests that BACs preferentially concentrate in sediment rather than in water.

  17. Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on-line solid-phase extraction technique.

    Science.gov (United States)

    Uchiyama, Kazuhisa; Kondo, Mari; Yokochi, Rika; Takeuchi, Yuri; Yamamoto, Atsushi; Inoue, Yoshinori

    2011-07-01

    A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Flow injection microfluidic device with on-line fluorescent derivatization for the determination of Cr(III) and Cr(VI) in water samples after solid phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Guilong [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China); He, Qiang, E-mail: heqiang0980@163.com [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Lu, Ying [Department of Mathematics and Physics, Armed Police College, Chengdu, 610213 (China); Huang, Jing [Research Center for Advanced Computation, College of Science, Xihua University, Chengdu, 610039 (China); Lin, Jin-Ming, E-mail: jmlin@mail.tsinghua.edu.cn [Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China)

    2017-02-22

    In this paper, a rapid and simple method using magnetic multi-walled carbon nanotubes (MWCNTS), as a solid-phase extraction (SPE) sorbent, was successfully developed for extraction and preconcentration trace amounts of Cr(III) in water samples. The synthesized magnetic-MWCNTs nanocomposite was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). A rhodamine derivative (R1) was synthesized and characterized as a highly selective and sensitive fluorescent derivatizing agent for Cr(III). After SPE procedure, Cr(III) analysis was performed by flow injection microfluidic chip with on-line fluorescent derivatization and laser-induced fluorescence (LIF) spectroscopy detection. The parameters, which affected the efficiency of the developed method were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0–10.0 nM, with a detection limit of 0.094 nM and an enrichment factor of 38. Furthermore, real water samples were analyzed and good recoveries were obtained from 91.0 to 101.6%. - Graphical abstract: Flow injection microfluidic device with on-line fluorescent derivatization and detection coupled to LIF. - Highlights: • A highly selective and sensitive derivatizing reagent for Cr(III) was synthesized and characterized. • The magnetic-MWCNTs nanocomposite as a SPE sorbent was successfully synthesized and characterized. • A new portable detection system was developed for microfluidic chip FIA platform.

  19. Looking into individual coffee beans during the roasting process: direct micro-probe sampling on-line photo-ionisation mass spectrometric analysis of coffee roasting gases.

    Science.gov (United States)

    Hertz-Schünemann, Romy; Streibel, Thorsten; Ehlert, Sven; Zimmermann, Ralf

    2013-09-01

    A micro-probe (μ-probe) gas sampling device for on-line analysis of gases evolving in confined, small objects by single-photon ionisation time-of-flight mass spectrometry (SPI-TOFMS) was developed. The technique is applied for the first time in a feasibility study to record the formation of volatile and flavour compounds during the roasting process within (inside) or in the direct vicinity (outside) of individual coffee beans. A real-time on-line analysis of evolving volatile and semi-volatile organic compounds (VOC and SVOC) as they are formed under the mild pyrolytic conditions of the roasting process was performed. The soft-ionisation mass spectra depict a molecular ion signature, which is well corresponding with the existing knowledge of coffee roasting and evolving compounds. Additionally, thereby it is possible to discriminate between Coffea arabica (Arabica) and Coffea canephora (Robusta). The recognized differences in the roasting gas profiles reflect the differences in the precursor composition of the coffee cultivars very well. Furthermore, a well-known set of marker compounds for Arabica and Robusta, namely the lipids kahweol and cafestol (detected in their dehydrated form at m/z 296 and m/z 298, respectively) were observed. If the variation in time of different compounds is observed, distinctly different evolution behaviours were detected. Here, phenol (m/z 94) and caffeine (m/z 194) are exemplary chosen, whereas phenol shows very sharp emission peaks, caffeine do not have this highly transient behaviour. Finally, the changes of the chemical signature as a function of the roasting time, the influence of sampling position (inside, outside) and cultivar (Arabica, Robusta) is investigated by multivariate statistics (PCA). In summary, this pilot study demonstrates the high potential of the measurement technique to enhance the fundamental knowledge of the formation processes of volatile and semi-volatile flavour compounds inside the individual coffee bean.

  20. Optimization of PMAxx pretreatment to distinguish between human norovirus with intact and altered capsids in shellfish and sewage samples.

    Science.gov (United States)

    Randazzo, Walter; Khezri, Mohammad; Ollivier, Joanna; Le Guyader, Françoise S; Rodríguez-Díaz, Jesús; Aznar, Rosa; Sánchez, Gloria

    2018-02-02

    Shellfish contamination by human noroviruses (HuNoVs) is a serious health and economic problem. Recently an ISO procedure based on RT-qPCR for the quantitative detection of HuNoVs in shellfish has been issued, but these procedures cannot discriminate between inactivated and potentially infectious viruses. The aim of the present study was to optimize a pretreatment using PMAxx to better discriminate between intact and heat-treated HuNoVs in shellfish and sewage. To this end, the optimal conditions (30min incubation with 100μM of PMAxx and 0.5% of Triton, and double photoactivation) were applied to mussels, oysters and cockles artificially inoculated with thermally-inactivated (99°C for 5min) HuNoV GI and GII. This pretreatment reduced the signal of thermally-inactivated HuNoV GI in cockles and HuNoV GII in mussels by >3 log. Additionally, this pretreatment reduced the signal of thermally-inactivated HuNoV GI and GII between 1 and 1.5 log in oysters. Thermal inactivation of HuNoV GI and GII in PBS, sewage and bioaccumulated oysters was also evaluated by the PMAxx-Triton pretreatment. Results showed significant differences between reductions observed in the control and PMAxx-treated samples in PBS following treatment at 72 and 95°C for 15min. In sewage, the RT-qPCR signal of HuNoV GI was completely removed by the PMAxx pretreatment after heating at 72 and 95°C, while the RT-qPCR signal for HuNoV GII was completely eliminated only at 95°C. Finally, the PMAxx-Triton pretreatment was applied to naturally contaminated sewage and oysters, resulting in most of the HuNoV genomes quantified in sewage and oyster samples (12 out of 17) corresponding to undamaged capsids. Although this procedure may still overestimate infectivity, the PMAxx-Triton pretreatment represents a step forward to better interpret the quantification of intact HuNoVs in complex matrices, such as sewage and shellfish, and it could certainly be included in the procedures based on RT-qPCR. Copyright

  1. Rapid and automated on-line solid phase extraction HPLC-MS/MS with peak focusing for the determination of ochratoxin A in wine samples.

    Science.gov (United States)

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Pagano, Imma; Russo, Mariateresa; Rastrelli, Luca

    2018-04-01

    This study reports a fast and automated analytical procedure based on an on-line SPE-HPLC-MS/MS method for the automatic pre-concentration, clean up and sensitive determination of OTA in wine. The amount of OTA contained in 100μL of sample (pH≅5.5) was retained and concentrated on an Oasis MAX SPE cartridge. After a washing step to remove matrix interferents, the analyte was eluted in back-flush mode and the eluent from the SPE column was diluted through a mixing Tee, using an aqueous solution before the chromatographic separation achieved on a monolithic column. The developed method has been validated according to EU regulation N. 519/2014 and applied for the analysis of 41 red and 17 white wines. The developed method features minimal sample handling, low solvent consumption, high sample throughput, low analysis cost and provides an accurate and highly selective results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Analysis of hydroxamate siderophores in soil solution using liquid chromatography with mass spectrometry and tandem mass spectrometry with on-line sample preconcentration.

    Science.gov (United States)

    Olofsson, Madelen A; Bylund, Dan

    2015-10-01

    A liquid chromatography with electrospray ionization mass spectrometry method was developed to quantitatively and qualitatively analyze 13 hydroxamate siderophores (ferrichrome, ferrirubin, ferrirhodin, ferrichrysin, ferricrocin, ferrioxamine B, D1 , E and G, neocoprogen I and II, coprogen and triacetylfusarinine C). Samples were preconcentrated on-line by a switch-valve setup prior to analyte separation on a Kinetex C18 column. Gradient elution was performed using a mixture of an ammonium formate buffer and acetonitrile. Total analysis time including column conditioning was 20.5 min. Analytes were fragmented by applying collision-induced dissociation, enabling structural identification by tandem mass spectrometry. Limit of detection values for the selected ion monitoring method ranged from 71 pM to 1.5 nM with corresponding values of two to nine times higher for the multiple reaction monitoring method. The liquid chromatography with mass spectrometry method resulted in a robust and sensitive quantification of hydroxamate siderophores as indicated by retention time stability, linearity, sensitivity, precision and recovery. The analytical error of the methods, assessed through random-order, duplicate analysis of soil samples extracted with a mixture of 10 mM phosphate buffer and methanol, appears negligible in relation to between-sample variations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Rapid determination of 99Tc in environmental samples by high resolution ICP-MS coupled with on-line flow injection system

    International Nuclear Information System (INIS)

    Kim, C.K.; Kim, C.S.; Rho, B.H.; Lee, J.I.

    2002-01-01

    High resolution inductively coupled plasma mass spectrometry coupled with an on-line flow injection system (FI-HR-ICP-MS) was applied to determine the ultra-trace level 99 Tc in soil. The flow injection system (PrepLab TM ) was composed of two TEVA-Spec R resins, reduced remarkably the sample amounts and the analysis time, compared to the conventional analytical methods. In the flow injection system, Mo and Ru were sufficiently eliminated by using the flow injection system, with the decontamination factors of 1.6 x 10 4 and 9.9 x 10 5 , respectively. With the present method, it was possible to determine ultra-low level of 99 Tc in 3∼6 soil at 3-5 hours of analysis time per sample. The relative standard deviation for each sample was less than 4%. The detection limits for 99 Tc was 85 fg x ml -1 (0.05 mBq x ml -1 ), which was calculated from the three times standard deviation of the count rate of the blank. (author)

  4. On-Line Organic Solvent Field Enhanced Sample Injection in Capillary Zone Electrophoresis for Analysis of Quetiapine in Beagle Dog Plasma

    Directory of Open Access Journals (Sweden)

    Yuqing Cao

    2016-01-01

    Full Text Available A rapid and sensitive capillary zone electrophoresis (CZE method with field enhanced sample injection (FESI was developed and validated for the determination of quetiapine fumarate in beagle dog plasma, with a sample pretreatment by LLE in 96-well deep format plate. The optimum separation was carried out in an uncoated 31.2 cm × 75 μm fused-silica capillary with an applied voltage of 13 kV. The electrophoretic analysis was performed by 50 mM phosphate at pH 2.5. The detection wavelength was 210 nm. Under these optimized conditions, FESI with acetonitrile enhanced the sensitivity of quetiapine about 40–50 folds in total. The method was suitably validated with respect to stability, specificity, linearity, lower limit of quantitation, accuracy, precision and extraction recovery. Using mirtazapine as an internal standard (100 ng/mL, the response of quetiapine was linear over the range of 1–1000 ng/mL. The lower limit of quantification was 1 ng/mL. The intra- and inter-day precisions for the assay were within 4.8% and 12.7%, respectively. The method represents the first application of FESI-CZE to the analysis of quetiapine fumarate in beagle dog plasma after oral administration.

  5. Comparative Study of the Effect of Sample Pretreatment and Extraction on the Determination of Flavonoids from Lemon (Citrus limon)

    Science.gov (United States)

    Ledesma-Escobar, Carlos A.; Priego-Capote, Feliciano; Luque de Castro, María D.

    2016-01-01

    Background Flavonoids have shown to exert multiple beneficial effects on human health, being also appreciated by both food and pharmaceutical industries. Citrus fruits are a key source of flavonoids, thus promoting studies to obtain them. Characteristics of these studies are the discrepancies among sample pretreatments and among extraction methods, and also the scant number of comparative studies developed so far. Objective Evaluate the effect of both the sample pretreatment and the extraction method on the profile of flavonoids isolated from lemon. Results Extracts from fresh, lyophilized and air-dried samples obtained by shaking extraction (SE), ultrasound-assisted extraction (USAE), microwave-assisted extraction (MAE) and superheated liquid extraction (SHLE) were analyzed by LC–QTOF MS/MS, and 32 flavonoids were tentatively identified using MS/MS information. ANOVA applied to the data from fresh and dehydrated samples and from extraction by the different methods revealed that 26 and 32 flavonoids, respectively, were significant (p≤0.01). The pairwise comparison (Tukey HSD; p≤0.01) showed that lyophilized samples are more different from fresh samples than from air-dried samples; also, principal component analysis (PCA) showed a clear discrimination among sample pretreatment strategies and suggested that such differences are mainly created by the abundance of major flavonoids. On the other hand, pairwise comparison of extraction methods revealed that USAE and MAE provided quite similar extracts, being SHLE extracts different from the other two. In this case, PCA showed a clear discrimination among extraction methods, and their position in the scores plot suggests a lower abundance of flavonoids in the extracts from SHLE. In the two PCA the loadings plots revealed a trend to forming groups according to flavonoid aglycones. Conclusions The present study shows clear discrimination caused by both sample pretreatments and extraction methods. Under the studied

  6. A sustainable on-line CapLC method for quantifying antifouling agents like irgarol-1051 and diuron in water samples: Estimation of the carbon footprint.

    Science.gov (United States)

    Pla-Tolós, J; Serra-Mora, P; Hakobyan, L; Molins-Legua, C; Moliner-Martinez, Y; Campins-Falcó, P

    2016-11-01

    In this work, in-tube solid phase microextraction (in-tube SPME) coupled to capillary LC (CapLC) with diode array detection has been reported, for on-line extraction and enrichment of booster biocides (irgarol-1051 and diuron) included in Water Frame Directive 2013/39/UE (WFD). The analytical performance has been successfully demonstrated. Furthermore, in the present work, the environmental friendliness of the procedure has been quantified by means of the implementation of the carbon footprint calculation of the analytical procedure and the comparison with other methodologies previously reported. Under the optimum conditions, the method presents good linearity over the range assayed, 0.05-10μg/L for irgarol-1051 and 0.7-10μg/L for diuron. The LODs were 0.015μg/L and 0.2μg/L for irgarol-1051 and diuron, respectively. Precision was also satisfactory (relative standard deviation, RSDcarbon footprint values for the proposed procedure consolidate the operational efficiency (analytical and environmental performance) of in-tube SPME-CapLC-DAD, in general, and in particular for determining irgarol-1051 and diuron in water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Development and application of an on-line sequential injection system for the separation of artificial and natural radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Kim, C.-K.; Sansone, U.; Martin, P.; Kim, C.-S.

    2007-02-01

    The Chemistry Unit of the Physics, Chemistry and Instrumentation Laboratory in the IAEA's Seibersdorf Laboratory in Austria, has the programmatic responsibility to provide assistance to Member State laboratories in maintaining and improving the reliability of analytical measurement results, both in trace element and radionuclide determinations. This is accomplished through the provision of reference materials of terrestrial origin, validated analytical procedures, training in the implementation of internal quality control, and through the evaluation of measurement performance by organization of worldwide and regional interlaboratory comparison exercises. In this framework an on-line sequential injection (SI) system was developed, which can be widely used for the separation and preconcentration of target analytes from diverse environmental samples. The system enables the separation time to be shortened by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in a chromatographic column. The SI system was successfully applied to the separation of Pu in IAEA reference material (IAEA Soil-6) and to the sequential separation of 210 Po and 210 Pb in phosphogypsum candidate reference material. The replicate analysis results of Pu in IAEA reference material (Soil-6) obtained with the SI system are in good agreement with the recommended value within 5% of standard deviation. The SI system enabled a halving in the separation time required for of radionuclides

  8. Monitoring of an esterification reaction by on-line direct liquid sampling mass spectrometry and in-line mid infrared spectrometry with an attenuated total reflectance probe

    International Nuclear Information System (INIS)

    Owen, Andrew W.; McAulay, Edith A.J.; Nordon, Alison; Littlejohn, David; Lynch, Thomas P.; Lancaster, J. Steven; Wright, Robert G.

    2014-01-01

    Highlights: • High efficiency thermal vaporiser designed and used for on-line reaction monitoring. • Concentration profiles of all reactants and products obtained from mass spectra. • By-product formed from the presence of an impurity detected by MS but not MIR. • Mass spectrometry can detect trace and bulk components unlike molecular spectrometry. - Abstract: A specially designed thermal vaporiser was used with a process mass spectrometer designed for gas analysis to monitor the esterification of butan-1-ol and acetic anhydride. The reaction was conducted at two scales: in a 150 mL flask and a 1 L jacketed batch reactor, with liquid delivery flow rates to the vaporiser of 0.1 and 1.0 mL min −1 , respectively. Mass spectrometry measurements were made at selected ion masses, and classical least squares multivariate linear regression was used to produce concentration profiles for the reactants, products and catalyst. The extent of reaction was obtained from the butyl acetate profile and found to be 83% and 76% at 40 °C and 20 °C, respectively, at the 1 L scale. Reactions in the 1 L reactor were also monitored by in-line mid-infrared (MIR) spectrometry; off-line gas chromatography (GC) was used as a reference technique when building partial least squares (PLS) multivariate calibration models for prediction of butyl acetate concentrations from the MIR spectra. In validation experiments, good agreement was achieved between the concentration of butyl acetate obtained from in-line MIR spectra and off-line GC. In the initial few minutes of the reaction the profiles for butyl acetate derived from on-line direct liquid sampling mass spectrometry (DLSMS) differed from those of in-line MIR spectrometry owing to the 2 min transfer time between the reactor and mass spectrometer. As the reaction proceeded, however, the difference between the concentration profiles became less noticeable. DLSMS had advantages over in-line MIR spectrometry as it was easier to generate

  9. Improved method for the determination of serotonin in plasma by high-performance liquid chromatography using on-line sample pre-treatment

    NARCIS (Netherlands)

    Takkenberg, B.; Endert, E.; van Ingen, H. E.; Ackermans, M.

    1991-01-01

    An improved method for the determination of serotonin in platelet-rich plasma (PRP) and platelet-poor plasma (PPP), by reversed-phase high-performance liquid chromatography with electrochemical detection and direct plasma injection, is described. The chromatographic system comprises a strong

  10. On-line hydrogen-isotope measurements of organic samples using elemental chromium: An extension for high temperature elemental-analyzer techniques

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B.; Meijer, Harro A.J.; Brand, Willi A.; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ2H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ2H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  11. On-line hydrogen-isotope measurements of organic samples using elemental chromium: an extension for high temperature elemental-analyzer techniques.

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B; Meijer, Harro A J; Brand, Willi A; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ(2)H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ(2)H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  12. Processing Adipose-Rich Mohs Samples: A Comparative Study of Effectiveness of Pretreatment With Liquid Nitrogen Versus Flash Freezing Spray.

    Science.gov (United States)

    Reserva, Jeave; Kozel, Zachary; Krol, Cindy; Speiser, Jodi; Adams, William; Tung, Rebecca

    2017-11-01

    Processing of adipose-rich Mohs micrographic surgery (MMS) specimens poses challenges that may preclude complete margin evaluation. In this setting, the value of additional freezing methods using various cooling agents has not been previously investigated. The aim of this study is to compare the frozen section quality of high-adipose Mohs specimens processed without additional cooling treatments versus those pretreated with 1,1,1,2-tetrafluoroethane (TFE) or liquid nitrogen (LN2). A set of 3 sections were each taken from 24 adipose-rich Mohs micrographic surgery specimens. A section from each set was subjected to either no additional cooling treatment (control), two 10-second pulse sprays of 1,1,1,2-tetrafluoroethane, or three 2-second pulse sprays of LN2. After staining, 2 blinded raters evaluated slide quality based on the presence or absence of the following features: margin completeness, nuclear clearing, epidermal or adipose folding, holes, or venetian blind-like artifacts. Pretreatment of the sample with LN2 produced a significantly (P < 0.001) greater number of high-quality slides (19/24) compared to pretreatment with 1,1,1,2-tetrafluoroethane (1/24) and no additional treatment (0/24). The adjunctive use of LN2 spray before tissue embedding circumvents the challenges of processing "thick" (high-adipose) specimens and facilitates the production of high-quality frozen section slides during Mohs micrographic surgery.

  13. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples.

    Science.gov (United States)

    Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-03-18

    Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems.

  14. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples

    Directory of Open Access Journals (Sweden)

    Pengyu Zhu

    2016-03-01

    Full Text Available Digital polymerase chain reaction (PCR has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ, sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO genome samples using commercial digital PCR detection systems.

  15. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn...

  16. Determination of thromboxanes, leukotrienes and lipoxins using high-temperature capillary liquid chromatography-tandem mass spectrometry and on-line sample preparation

    DEFF Research Database (Denmark)

    Dahl, Sandra Rinne; Kleiveland, Charlotte Ramstad; Kassem, Moustapha

    2009-01-01

    An on-line strong cation-exchange (SCX)-reversed-phase (RP) capillary liquid chromatographic (cLC) method with ion-trap tandem mass spectrometric (IT-MS/MS) detection for the simultaneous determination of thromboxane (TX) B(2), TXB(3), leukotriene (LT) B(4), LTD(4) and lipoxin (LX) A(4) in cell...

  17. Rational approach to solvent system selection for liquid-liquid extraction-assisted sample pretreatment in counter-current chromatography.

    Science.gov (United States)

    Wang, Jiajia; Gu, Dongyu; Wang, Miao; Guo, Xinfeng; Li, Haoquan; Dong, Yue; Guo, Hong; Wang, Yi; Fan, Mengqi; Yang, Yi

    2017-05-15

    A rational liquid-liquid extraction approach was established to pre-treat samples for high-speed counter-current chromatography (HSCCC). n-Hexane-ethyl acetate-methanol-water (4:5:4:5, v/v) and (1:5:1:5, v/v) were selected as solvent systems for liquid-liquid extraction by systematically screening K of target compounds to remove low- and high-polarity impurities in the sample, respectively. After liquid-liquid extraction was performed, 1.4g of crude sample II was obtained from 18.5g of crude sample I which was extracted from the flowers of Robinia pseudoacacia L., and then separated with HSCCC by using a solvent system composed of n-hexane-ethyl acetate-methanol-water (1:2:1:2, v/v). As a result, 31mg of robinin and 37mg of kaempferol 7-O-α-l-rhamnopyranoside were isolated from 200mg of crude sample II in a single run of HSCCC. A scale-up separation was also performed, and 160mg of robinin with 95% purity and 188mg of kaempferol 7-O-α-l-rhamnopyranoside with 97% purity were produced from 1.2g of crude sample II. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. imFASP: An integrated approach combining in-situ filter-aided sample pretreatment with microwave-assisted protein digestion for fast and efficient proteome sample preparation.

    Science.gov (United States)

    Zhao, Qun; Fang, Fei; Wu, Ci; Wu, Qi; Liang, Yu; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2016-03-17

    An integrated sample preparation method, termed "imFASP", which combined in-situ filter-aided sample pretreatment and microwave-assisted trypsin digestion, was developed for preparation of microgram and even nanogram amounts of complex protein samples with high efficiency in 1 h. For imFASP method, proteins dissolved in 8 M urea were loaded onto a filter device with molecular weight cut off (MWCO) as 10 kDa, followed by in-situ protein preconcentration, denaturation, reduction, alkylation, and microwave-assisted tryptic digestion. Compared with traditional in-solution sample preparation method, imFASP method generated more protein and peptide identifications (IDs) from preparation of 45 μg Escherichia coli protein sample due to the higher efficiency, and the sample preparation throughput was significantly improved by 14 times (1 h vs. 15 h). More importantly, when the starting amounts of E. coli cell lysate decreased to nanogram level (50-500 ng), the protein and peptide identified by imFASP method were improved at least 30% and 44%, compared with traditional in-solution preparation method, suggesting dramatically higher peptide recovery of imFASP method for trace amounts of complex proteome samples. All these results demonstrate that the imFASP method developed here is of high potential for high efficient and high throughput preparation of trace amounts of complex proteome samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Trace analysis of halogenated hydrocarbons in gaseous samples by on-line enrichment in an adsorption trap, on-column cold-trapping and capillary gas chromatography. I.Method and instrumentation

    NARCIS (Netherlands)

    Noij, T.H.M.; Fabian, P.; Borchers, R.; Janssen, F.; Cramers, C.A.M.G.; Rijks, J.A.

    1987-01-01

    A method is described for the determination of halocarbons in gaseous samples down to the ppt level (1:1012, v/v), consisting of successive on-line sub-ambient enrichment on an adsorbent, on-column cryofocusing, capillary gas chromatography and electron-capture detection. The quantitative aspects of

  20. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    NARCIS (Netherlands)

    Slobodník, J.; Oztekizan, O.; Lingeman, H.; Brinkman, U.A.T.

    1996-01-01

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2

  1. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    International Nuclear Information System (INIS)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario; Pena, Rosa M.; Herrero, Carlos

    2008-01-01

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L -1 for Na, -1 for K, 0.02-4.83 mg L -1 for Mg content, -1 for Cu and 0.03-13.10 mg L -1 for Ca

  2. Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

    Science.gov (United States)

    Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E

    2017-09-25

    Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

  3. [Pretreatment of Aluminum-Lithium Alloy Sample and Determination of Argentum and Lithium by Spectral Analysis].

    Science.gov (United States)

    Zhou, Hui; Tan, Qian; Gao, Ya-ling; Sang, Shi-hua; Chen, Wen

    2015-10-01

    Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), Flame Atomic Absorption Spectrometry (FAAS) and Visible Spectrometry (VS) was applied for determination of Ag and Li in lithium-aluminium alloy standard sample and test sample, their respective advantages and disadvantages were compared, the excellent selectivity of ICP-OES was confirmed by analyses of certified standard sample. Three different sample digestion methods were compared and discussed in this study. It was found that the better accuracy would be obtained by digesting sample with chloroazotic acid while the content of Li was measured by FAAS, and it was better to digest sample with hydrochloric acid and hydrogen peroxide while determining Ag and Li by ICP-OES simultaneously and determining Ag by FAAS and VS. The interference of co-existing elements and elimination methods was detailedly discussed. Ammonium hydroxide was added to adjust the sample solution into alkalescent and Al, Ti, Zr was precipitated by forming hydroxide precipitation, Mg and Cu was formed complex precipitation with 8-hydroxyquinoline in this condition, then the interference from matrix element to determinate Ag by FAAS was eliminated. In addition, phosphate was used to precipitate Ti to eliminate its interference for determination of Li by FAAS. The same treatment of determination for Ag by FAAS was used to eliminate the interference of matrix element for determination of Ag by VS, the excess of nitrate was added into sample and heated to release Ag+ from silver chloride complex, and the color of 8-hydroxyquinoline was eliminated because of decomposed by heating. The accuracy of analysis result for standard sample was conspicuously improved which confirms the efficient of the method to eliminate interference in this study. The optimal digestion method and eliminate interference method was applied to lithium-aluminium alloy samples. The recovery of samples was from 100.39% to 103.01% by ICP-OES determination for Ag

  4. Recent advances in the determination of tocopherols in biological fluids: from sample pretreatment and liquid chromatography to clinical studies.

    Science.gov (United States)

    Cervinkova, Barbora; Krcmova, Lenka Kujovska; Solichova, Dagmar; Melichar, Bohuslav; Solich, Petr

    2016-04-01

    Vitamin E comprises eight related compounds: α-, β-, γ-, δ-tocopherols and α-, β-, γ-, δ-tocotrienols. In the past, α-tocopherol has been the isomer that was studied most, and its anti-inflammatory and anti-proliferative effects have been described. Therefore, many prevention trials have investigated the effect of α-tocopherol on human health. Current research studies have also defined the important roles of other tocopherols, such as anti-inflammatory, anti-proliferative and cancer preventative effects. Knowledge of the individual tocopherols could help to understand their roles in various metabolic pathways. This review summarizes the recent trends in sample pretreatment, liquid chromatography and selected applications of the determination of tocopherols in various biological materials. The relationship between tocopherol isomers and serious diseases is also described. Graphical Abstract Article structure.

  5. Pretreatment procedures applied to samples to be analysed by neutron activation analysis at CDTN/CNEN

    International Nuclear Information System (INIS)

    Francisco, Dovenir; Menezes, Maria Angela de Barros Correia

    2009-01-01

    The neutron activation technique - using several methods - has been applied in 80% of the analytical demand of Division for Reactor and Analytical Techniques at CDTN/CNEN, Belo Horizonte, Minas Gerais. This scenario emphasizes the responsibility of the Laboratory to provide and assure the quality of the measurements. The first step to assure the results quality is the preparation of the samples. Therefore, this paper describes the experimental procedures adopted at CDTN/CNEN in order to uniform conditions of analysis and to avoid contaminations by elements present everywhere. Some of the procedures are based on methods described in the literature; others are based on many years of experience preparing samples from many kinds of matrices. The procedures described are related to geological material - soil, sediment, rock, gems, clay, archaeological ceramics and ore - biological materials - hair, fish, plants, food - water, etc. Analytical results in sediment samples are shown as n example pointing out the efficiency of the experimental procedure. (author)

  6. Concurrent Lactic and Volatile Fatty Acid Analysis of Microbial Fermentation Samples by Gas Chromatography with Heat Pre-treatment.

    Science.gov (United States)

    Darwin; WipaCharles; Cord-Ruwisch, Ralf

    2018-01-01

    Organic acid analysis of fermentation samples can be readily achieved by gas chromatography (GC), which detects volatile organic acids. However, lactic acid, a key fermentation acid is non-volatile and can hence not be quantified by regular GC analysis. However the addition of periodic acid to organic acid samples has been shown to enable lactic acid analysis by GC, as periodic acid oxidizes lactic acid to the volatile acetaldehyde. Direct GC injection of lactic acid standards and periodic acid generated inconsistent and irreproducible peaks, possibly due to incomplete lactic acid oxidation to acetaldehyde. The described method is developed to improve lactic acid analysis by GC by using a heat treated derivatization pre-treatment, such that it becomes independent of the retention time and temperature selection of the GC injector. Samples containing lactic acid were amended by periodic acid and heated in a sealed test tube at 100°C for at least 45 min before injecting it to the GC. Reproducible and consistent peaks of acetaldehyde were obtained. Simultaneous determination of lactic acid, acetone, ethanol, butanol, volatile fatty acids could also be accomplished by applying this GC method, enabling precise and convenient organic acid analysis of biological samples such as anaerobic digestion and fermentation processes. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Status and Needs Research for On-line Monitoring of VOCs Emissions from Stationary Sources

    Science.gov (United States)

    Zhou, Gang; Wang, Qiang; Zhong, Qi; Zhao, Jinbao; Yang, Kai

    2018-01-01

    Based on atmospheric volatile organic compounds (VOCs) pollution control requirements during the twelfth-five year plan and the current status of monitoring and management at home and abroad, instrumental architecture and technical characteristics of continuous emission monitoring systems (CEMS) for VOCs emission from stationary sources are investigated and researched. Technological development needs of VOCs emission on-line monitoring techniques for stationary sources in china are proposed from the system sampling pretreatment technology and analytical measurement techniques.

  8. Combination of a Sample Pretreatment Microfluidic Device with a Photoluminescent Graphene Oxide Quantum Dot Sensor for Trace Lead Detection.

    Science.gov (United States)

    Park, Minsu; Ha, Hyun Dong; Kim, Yong Tae; Jung, Jae Hwan; Kim, Shin-Hyun; Kim, Do Hyun; Seo, Tae Seok

    2015-11-03

    A novel trace lead ion (Pb(2+)) detection platform by combining a microfluidic sample pretreatment device with a DNA aptamer linked photoluminescent graphene oxide quantum dot (GOQD) sensor was proposed. The multilayered microdevice included a microchamber which was packed with cation exchange resins for preconcentrating metal ions. The sample loading and recovery were automatically actuated by a peristaltic polydimethylsiloxane micropump with a flow rate of 84 μL/min. Effects of the micropump actuation time, metal ion concentration, pH, and the volumes of the sample and eluent on the metal ion capture and preconcentration efficiency were investigated on a chip. The Pb(2+) samples whose concentrations ranged from 0.48 nM to 1.2 μM were successfully recovered with a preconcentration factor value between 4 and 5. Then, the preconcentrated metal ions were quantitatively analyzed with a DNA aptamer modified GOQD. The DNA aptamer on the GOQD specifically captured the target Pb(2+) which can induce electron transfer from GOQD to Pb(2+) upon UV irradiation, thereby resulting in the fluorescence quenching of the GOQD. The disturbing effect of foreign anions on the Pb(2+) detection and the spiked Pb(2+) real samples were also analyzed. The proposed GOQD metal ion sensor exhibited highly sensitive Pb(2+) detection with a detection limit of 0.64 nM and a dynamic range from 1 to 1000 nM. The on-chip preconcentration of the trace metal ions from a large-volume sample followed by the metal ion detection by the fluorescent GOQD sensor can provide an advanced platform for on-site water pollution screening.

  9. Study on different pre-treatment procedures for metal determination in Orujo spirit samples by ICP-AES

    Energy Technology Data Exchange (ETDEWEB)

    Barciela, Julia; Vilar, Manuela; Garcia-Martin, Sagrario [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain); Pena, Rosa M. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: qarosa@lugo.usc.es; Herrero, Carlos [Departamento de Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Universidad de Santiago de Compostela, Campus de Lugo, 27002 Lugo (Spain)], E-mail: cherrero@lugo.usc.es

    2008-10-17

    In this work several pre-treatment methods were studied for metal (Na, K, Mg, Cu and Ca) determination in Orujo spirit samples using inductively coupled plasma atomic emission spectrometry (ICP-AES). Dilution, digestion, evaporation, and cryogenic desolvatation techniques were comparatively evaluated. Because of their analytical characteristics, digestion and evaporation with nitrogen current were found to be appropriate procedures for the determination of metals in alcoholic spirit samples. Yet, if simplicity and application time are to be considered, the latter-evaporation in a water bath with a nitrogen current-stands out as the optimum procedure for any further determinations in Orujo samples by ICP-AES. Low detection levels and wide linear ranges (sufficient to determine these metals in the samples studied) were achieved for each metal. The recoveries (in the 97.5-100.5% range) and the precision (R.S.D. lower than 5.6%) obtained were also satisfactory. The selected procedure was applied to determine the content of metals in 80 representative Galician Orujo spirit samples with and without a Certified Brand of Origin (CBO) which had been produced using different distillation systems. The metal concentrations ranged between 0.37 and 79.7 mg L{sup -1} for Na,

  10. Analysis of multivariate stochastic signals sampled by on-line particle analyzers: Application to the quantitative assessment of occupational exposure to NOAA in multisource industrial scenarios (MSIS)

    International Nuclear Information System (INIS)

    De Ipiña, J M López; Vaquero, C; Gutierrez-Cañas, C; Pui, D Y H

    2015-01-01

    In multisource industrial scenarios (MSIS) coexist NOAA generating activities with other productive sources of airborne particles, such as parallel processes of manufacturing or electrical and diesel machinery. A distinctive characteristic of MSIS is the spatially complex distribution of aerosol sources, as well as their potential differences in dynamics, due to the feasibility of multi-task configuration at a given time. Thus, the background signal is expected to challenge the aerosol analyzers at a probably wide range of concentrations and size distributions, depending of the multisource configuration at a given time. Monitoring and prediction by using statistical analysis of time series captured by on-line particle analyzersin industrial scenarios, have been proven to be feasible in predicting PNC evolution provided a given quality of net signals (difference between signal at source and background). However the analysis and modelling of non-consistent time series, influenced by low levels of SNR (Signal-Noise Ratio) could build a misleading basis for decision making. In this context, this work explores the use of stochastic models based on ARIMA methodology to monitor and predict exposure values (PNC). The study was carried out in a MSIS where an case study focused on the manufacture of perforated tablets of nano-TiO 2 by cold pressing was performed. (paper)

  11. An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples.

    Science.gov (United States)

    Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor

    2018-02-01

    Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Systematic approach to optimize a pretreatment method for ultrasensitive liquid chromatography with tandem mass spectrometry analysis of multiple target compounds in biological samples.

    Science.gov (United States)

    Togashi, Kazutaka; Mutaguchi, Kuninori; Komuro, Setsuko; Kataoka, Makoto; Yamazaki, Hiroshi; Yamashita, Shinji

    2016-08-01

    In current approaches for new drug development, highly sensitive and robust analytical methods for the determination of test compounds in biological samples are essential. These analytical methods should be optimized for every target compound. However, for biological samples that contain multiple compounds as new drug candidates obtained by cassette dosing tests, it would be preferable to develop a single method that allows the determination of all compounds at once. This study aims to establish a systematic approach that enables a selection of the most appropriate pretreatment method for multiple target compounds without the use of their chemical information. We investigated the retention times of 27 known compounds under different mobile phase conditions and determined the required pretreatment of human plasma samples using several solid-phase and liquid-liquid extractions. From the relationship between retention time and recovery in a principal component analysis, appropriate pretreatments were categorized into several types. Based on the category, we have optimized a pretreatment method for the identification of three calcium channel blockers in human plasma. Plasma concentrations of these drugs in a cassette-dose clinical study at microdose level were successfully determined with a lower limit of quantitation of 0.2 pg/mL for diltiazem, 1 pg/mL for nicardipine, and 2 pg/mL for nifedipine. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  14. Simplifying sample pretreatment: application of dried blood spot (DBS) method to blood samples, including postmortem, for UHPLC-MS/MS analysis of drugs of abuse.

    Science.gov (United States)

    Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina

    2014-10-01

    The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis

    International Nuclear Information System (INIS)

    Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.

    2000-01-01

    The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring. (c)

  16. Use of an Open Port Sampling Interface Coupled to Electrospray Ionization for the On-Line Analysis of Organic Aerosol Particles

    Science.gov (United States)

    Swanson, Kenneth D.; Worth, Anne L.; Glish, Gary L.

    2018-02-01

    A simple design for an open port sampling interface coupled to electrospray ionization (OPSI-ESI) is presented for the analysis of organic aerosols. The design uses minimal modifications to a Bruker electrospray (ESI) emitter to create a continuous flow, self-aspirating open port sampling interface. Considerations are presented for introducing aerosol to the open port sampling interface including aerosol gas flow and solvent flow rates. The device has been demonstrated for use with an aerosol of nicotine as well as aerosol formed in the pyrolysis of biomass. Upon comparison with extractive electrospray ionization (EESI), this device has similar sensitivity with increased reproducibility by nearly a factor of three. The device has the form factor of a standard Bruker/Agilent ESI emitter and can be used without any further instrument modifications.

  17. On-line LC-GC and comprehensive two-dimensional LCxGC-ToF MS for the analysis of complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, Hans-Gerd [Central Analytical Science, Unilever Research and Development, P.O. Box 114, 3130 AC, Vlaardingen (Netherlands); Koning, Sjaak de [Separation Science Group, LECO Instrumente GmbH, Marie-Bernays-Ring 31, 41199, Moenchengladbach (Germany); Brinkman, Udo A.Th. [Department of Analytical Chemistry and Applied Spectroscopy, Free University, De Boelelaan 1083, 1081 HV, Amsterdam (Netherlands)

    2004-04-01

    LC x GC is a logical extension of LC-GC. Unlike LC-GC, which only allows detailed analysis of one group of analytes from a complex sample, LC x GC enables detailed mapping of the entire sample. Due to the high degree of orthogonality and the complementary nature of the two dimensions, the method has a very high resolving power. Comprehensive LC x GC chromatograms often show ordered structures which allow group-wise integration as well as detailed target compound analysis. Hyphenation with mass spectrometry is straightforward, which further widens the application range of the technique. (orig.)

  18. Molecularly imprinted polymer cartridges coupled on-line with high performance liquid chromatography for simple and rapid analysis of dextromethorphan in human plasma samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz

    2011-04-01

    In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Continuous-flow liquid microjunction surface sampling probe connected on-line with high-performance liquid chromatography/mass spectrometry for spatially resolved analysis of small molecules and proteins.

    Science.gov (United States)

    Van Berkel, Gary J; Kertesz, Vilmos

    2013-06-30

    A continuous-flow liquid microjunction surface sampling probe extracts soluble material from surfaces for direct ionization and detection by mass spectrometry. Demonstrated here is the on-line coupling of such a probe with high-performance liquid chromatography/mass spectrometry (HPLC/MS) enabling extraction, separation and detection of small molecules and proteins from surfaces in a spatially resolved (~0.5 mm diameter spots) manner. A continuous-flow liquid microjunction surface sampling probe was connected to a six-port, two-position valve for extract collection and injection to an HPLC column. A QTRAP® 5500 hybrid triple quadrupole linear ion trap equipped with a Turbo V™ ion source operated in positive electrospray ionization (ESI) mode was used for all experiments. The system operation was tested with the extraction, separation and detection of propranolol and associated metabolites from drug dosed tissues, caffeine from a coffee bean, cocaine from paper currency, and proteins from dried sheep blood spots on paper. Confirmed in the tissue were the parent drug and two different hydroxypropranolol glucuronides. The mass spectrometric response for these compounds from different locations in the liver showed an increase with increasing extraction time (5, 20 and 40 s). For on-line separation and detection/identification of extracted proteins from dried sheep blood spots, two major protein peaks dominated the chromatogram and could be correlated with the expected masses for the hemoglobin α and β chains. Spatially resolved sampling, separation, and detection of small molecules and proteins from surfaces can be accomplished using a continuous-flow liquid microjunction surface sampling probe coupled on-line with HPLC/MS detection. Published in 2013. This article is a U.S. Government work and is in the public domain in the USA.

  20. Application of cotton as a solid phase extraction sorbent for on-line preconcentration of copper in water samples prior to inductively coupled plasma optical emission spectrometry determination.

    Science.gov (United States)

    Faraji, Mohammad; Yamini, Yadollah; Shariati, Shahab

    2009-07-30

    Copper, as a heavy metal, is toxic for many biological systems. Thus, the determination of trace amounts of copper in environmental samples is of great importance. In the present work, a new method was developed for the determination of trace amounts of copper in water samples. The method is based on the formation of ternary Cu(II)-CAS-CTAB ion-pair and adsorption of it into a mini-column packed with cotton prior applying inductively coupled plasma optical emission spectrometry (ICP-OES). The experimental parameters that affected the extraction efficiency of the method such as pH, flow rate and volume of the sample solution, concentration of chromazurol S (CAS) and cethyltrimethylammonium bromide (CTAB) as well as type and concentration of eluent were investigated and optimized. The ion-pair (Cu(II)-CAS-CTAB) was quantitatively retained on the cotton under the optimum conditions, then eluted completely using a solution of 25% (v/v) 1-propanol in 0.5 mol L(-1) HNO(3) and directly introduced into the nebulizer of the ICP-OES. The detection limit (DL) of the method for copper was 40 ng L(-1) (V(sample)=100mL) and the relative standard deviation (R.S.D.) for the determination of copper at 10 microg L(-1) level was found to be 1.3%. The method was successfully applied to determine the trace amounts of copper in tap water, deep well water, seawater and two different mineral waters, and suitable recoveries were obtained (92-106%).

  1. Lead ultra-trace on-line preconcentration and determination using selective solid phase extraction and electrothermal atomic absorption spectrometry: applications in seawaters and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Vereda Alonso, E.; Siles Cordero, M.T.; Garcia de Torres, A.; Cano Pavon, J.M. [University of Malaga, Department of Analytical Chemistry Faculty of Sciences, Malaga (Spain)

    2006-08-15

    In this work, a new chelating resin [1,5-bis (2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide immobilised on aminopropyl-controlled pore glass (550 Aa; PSTH-cpg) was synthesised and packed in a microcolumn which replaced the sample tip of the autosampler arm. The system was applied to the preconcentration of lead. When microliters of 10% HNO{sub 3}, which acts as elution agent, pass through the microcolumn, the preconcentrated Pb(II) is eluted and directly deposited in a tungsten-rhodium coated graphite tube. With the use of the separation and preconcentration step and the permanent modifiers, the analytical characteristics of the technique were improved. The proposed method has a linear calibration range from 0.012 to 10 ng ml{sup -1} of lead. At a sample frequency of 36 h{sup -1} with a 90 s preconcentration time, the enrichment factor was 20.5, the detection and determination limits were 0.012 and 0.14 ng ml{sup -1}, respectively and the precision, expressed as relative standard deviation, was 3.2% (at 1 ng ml{sup -1}). Results from the determination of Pb in biological certified reference materials were in agreement with the certified values. Seawaters and other biological samples were analysed too. (orig.)

  2. Rapid Screening of Carboxylic Acids from Waste and Surface Waters by ESI-MS/MS Using Barium Ion Chemistry and On-Line Membrane Sampling

    Science.gov (United States)

    Duncan, Kyle D.; Volmer, Dietrich A.; Gill, Chris G.; Krogh, Erik T.

    2016-03-01

    Negative ion tandem mass spectrometric analysis of aliphatic carboxylic acids often yields only non-diagnostic ([M - H]-) ions with limited selective fragmentation. However, carboxylates cationized with Ba2+ have demonstrated efficient dissociation in positive ion mode, providing structurally diagnostic product ions. We report the application of barium adducts followed by collision induced dissociation (CID), to improve selectivity for rapid screening of carboxylic acids in complex aqueous samples. The quantitative MS/MS method presented utilizes common product ions of [M - H + Ba]+ precursor ions. The mechanism of product ion formation is investigated using isotopically labeled standards and a series of structurally related carboxylic acids. The results suggest that hydrogen atoms in the β and γ positions yield common product ions ([BaH]+ and [BaOH]+). Furthermore, the diagnostic product ion at m/z 196 serves as a qualifying ion for carboxylate species. This methodology has been successfully used in conjunction with condensed phase membrane introduction mass spectrometry (CP-MIMS), with barium acetate added directly to the methanol acceptor phase. The combination enables rapid screening of carboxylic acids directly from acidified water samples (wastewater effluent, spiked natural waters) using a capillary hollow fiber PDMS membrane immersion probe. We have applied this technique for the direct analysis of complex naphthenic acid mixtures spiked into natural surface waters using CP-MIMS. Selectivity at the ionization and tandem mass spectrometry level eliminate isobaric interferences from hydroxylated species present within the samples, which have been observed in negative electrospray ionization.

  3. Rapid Screening of Carboxylic Acids from Waste and Surface Waters by ESI-MS/MS Using Barium Ion Chemistry and On-Line Membrane Sampling.

    Science.gov (United States)

    Duncan, Kyle D; Volmer, Dietrich A; Gill, Chris G; Krogh, Erik T

    2016-03-01

    Negative ion tandem mass spectrometric analysis of aliphatic carboxylic acids often yields only non-diagnostic ([M - H](-)) ions with limited selective fragmentation. However, carboxylates cationized with Ba(2+) have demonstrated efficient dissociation in positive ion mode, providing structurally diagnostic product ions. We report the application of barium adducts followed by collision induced dissociation (CID), to improve selectivity for rapid screening of carboxylic acids in complex aqueous samples. The quantitative MS/MS method presented utilizes common product ions of [M - H + Ba](+) precursor ions. The mechanism of product ion formation is investigated using isotopically labeled standards and a series of structurally related carboxylic acids. The results suggest that hydrogen atoms in the β and γ positions yield common product ions ([BaH](+) and [BaOH](+)). Furthermore, the diagnostic product ion at m/z 196 serves as a qualifying ion for carboxylate species. This methodology has been successfully used in conjunction with condensed phase membrane introduction mass spectrometry (CP-MIMS), with barium acetate added directly to the methanol acceptor phase. The combination enables rapid screening of carboxylic acids directly from acidified water samples (wastewater effluent, spiked natural waters) using a capillary hollow fiber PDMS membrane immersion probe. We have applied this technique for the direct analysis of complex naphthenic acid mixtures spiked into natural surface waters using CP-MIMS. Selectivity at the ionization and tandem mass spectrometry level eliminate isobaric interferences from hydroxylated species present within the samples, which have been observed in negative electrospray ionization.

  4. An on-line push/pull perfusion-based hollow-fiber liquid-phase microextraction system for high-performance liquid chromatographic determination of alkylphenols in water samples.

    Science.gov (United States)

    Chao, Yu-Ying; Jian, Zhi-Xuan; Tu, Yi-Ming; Wang, Hsaio-Wen; Huang, Yeou-Lih

    2013-06-07

    In this study, we employed a novel on-line method, push/pull perfusion hollow-fiber liquid-phase microextraction (PPP-HF-LPME), to extract 4-tert-butylphenol, 2,4-di-tert-butylphenol, 4-n-nonylphenol, and 4-n-octylphenol from river and tap water samples; we then separated and quantified the extracted analytes through high-performance liquid chromatography (HPLC). Using this approach, we overcame the problem of fluid loss across the porous HF membrane to the donor phase, permitting on-line coupling of HF-LPME to HPLC. In our PPP-HF-LPME system, we used a push/pull syringe pump as the driving source to perfuse the acceptor phase, while employing a heating mantle and an ultrasonic probe to accelerate mass transfer. We optimized the experimental conditions such as the nature of the HF supported intermediary phase and the acceptor phase, the composition of the donor and acceptor phases, the sample temperature, and the sonication conditions. Our proposed method provided relative standard deviations of 3.1-6.2%, coefficients of determination (r(2)) of 0.9989-0.9998, and limits of detection of 0.03-0.2 ng mL(-1) for the analytes under the optimized conditions. When we applied this method to analyses of river and tap water samples, our results confirmed that this microextraction technique allows reliable monitoring of alkylphenols in water samples.

  5. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    Science.gov (United States)

    Slobodník, J; Oztezkizan, O; Lingeman, H; Brinkman, U A

    1996-10-25

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 l samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (> 2 l for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n = 3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 microgram/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10 x 2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 microgram

  6. Determination of antimony by electrochemical hydride generation atomic absorption spectrometry in samples with high iron content using chelating resins as on-line removal system

    International Nuclear Information System (INIS)

    Bolea, E.; Arroyo, D.; Laborda, F.; Castillo, J.R.

    2006-01-01

    A method for the removal of the interference caused by iron on electrochemical generation of stibine is proposed. It consists of a chelating resin Chelex 100 column integrated into a flow injection system and coupled to the electrochemical hydride generator quartz tube atomic absorption spectrometer (EcHG-QT-AAS). Iron, as Fe(II), is retained in the column with high efficiency, close to 99.9% under optimal conditions. No significant retention was observed for Sb(III) under same conditions and a 97 ± 5% signal recovery was achieved. An electrochemical hydride generator with a concentric configuration and a reticulated vitreous carbon cathode was employed. The system is able to determine antimony concentrations in the range of ng ml -1 in presence of iron concentrations up to 400 mg l -1 . The procedure was validated by analyzing PACS-2 marine sediments reference material with a 4% (w/w) iron content and a [Fe]:[Sb] ratio of 4000:1, which caused total antimony signal suppression on the electrochemical hydride generation system. A compost sample with high iron content (0.7%, w/w), was also analyzed. A good agreement was found on both samples with the certified value and the antimony concentration determined by ICP-MS, respectively

  7. On-line preconcentration of ultra-trace thallium(I in water samples with titanium dioxide nanoparticles and determination by graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Saeid Asadpour

    2016-11-01

    Full Text Available A new method has been developed for the determination of Tl(I based on simultaneous sorption and preconcentration with a microcolumn packed with TiO2 nanoparticle with a high specific surface area prepared by Sonochemical synthesis prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS. The optimum experimental parameters for preconcentration of thallium, such as elution condition, pH, and sample volume and flow rate have been investigated. Tl(I can be quantitatively retained by TiO2 nanoparticles at pH 9.0, then eluted completely with 1.0 mol L−1 HCl. The adsorption capacity of TiO2 nanoparticles for Tl(I was found to be 25 mg g−1. Also detection limit, precision (RSD, n = 8 and enrichment factor for Tl(I were 87 ng L−1, 6.4% and 100, respectively. The method has been applied for the determination of trace amounts of Tl(I in some environmental water samples with satisfactory results.

  8. Grafting 3-mercaptopropyl trimethoxysilane on multi-walled carbon nanotubes surface for improving on-line cadmium(II) preconcentration from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Corazza, Marcela Zanetti; Somera, Bruna Fabrin; Segatelli, Mariana Gava [Departamento de Quimica, Universidade Estadual de Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Campus Universitario, Londrina-PR, CEP 86051-990 (Brazil); Tarley, Cesar Ricardo Teixeira, E-mail: tarley@uel.br [Departamento de Quimica, Universidade Estadual de Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Campus Universitario, Londrina-PR, CEP 86051-990 (Brazil); Instituto Nacional de Ciencia e Tecnologia (INCT) de Bioanalitica, Universidade Estadual de Campinas (UNICAMP), Instituto de Quimica, Departamento de Quimica Analitica, Cidade Universitaria Zeferino, Vaz, s/n, CEP 13083-970, Campinas-SP (Brazil)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer 3-Mercaptopropyl trimethoxysilane grafted on MWCNT surface was prepared. Black-Right-Pointing-Pointer The material promoted an increase on performance of MWCNT for Cd{sup 2+} adsorption. Black-Right-Pointing-Pointer The life time of adsorbent was very high. Black-Right-Pointing-Pointer An improvement of 84% on the sensitivity was achieved. - Abstract: In the present study, the performance of multi-walled carbon nanotubes (MWCNTs) grafted with 3-mercaptopropyltrimethoxysilane (3-MPTMS), used as a solid phase extractor for Cd{sup 2+} preconcentration in a flow injection system coupled to flame atomic absorption spectrometry (FAAS), was evaluated. The procedure involved the preconcentration of 20.0 mL of Cd{sup 2+} solution at pH 7.5 (0.1 mol L{sup -1} buffer phosphate) through 70 mg of 3-MPTMS-grafted MWCNTs packed into a minicolumn at 6.0 mL min{sup -1}. The elution step was carried out with 1.0 mol L{sup -1} HCl. Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to estimate the extent of the MWCNT chemical modification. The 3-MPTMS-grafted MWCNTs provided a 1.68 times improvement in the sensitivity of the Cd{sup 2+} FAAS determination compared to the unsilanized oxidized MWCNTs. The following parameters were obtained: preconcentration factor of 31.5, consumptive index of 0.635 mL, sample throughput of 14 h{sup -1}, and concentration efficiency of 9.46 min{sup -1}. The analytical curve was constructed in the range of 1.0-60.0 {mu}g L{sup -1} (r = 0.9988), and the detection and quantification limits were found to be 0.15 {mu}g L{sup -1} and 0.62 {mu}g L{sup -1}, respectively. Different types of water samples and cigarette sample were successfully analyzed, and the results were compared using electrothermal atomic absorption spectrometry (ETAAS) as reference technique. In addition, the accuracy of proposed method was also checked by analysis of

  9. Development of a simple extraction cell with bi-directional continuous flow coupled on-line to ICP-MS for assessment of elemental associations in solid samples

    DEFF Research Database (Denmark)

    Buanuam, Janya; Tiptanasup, Kasipa; Shiowatana, Juwadee

    2006-01-01

    A continuous-flow system comprising a novel, custom-built extraction module and hyphenated with inductively coupled plasma-mass spectrometric (ICP-MS) detection is proposed for assessing metal mobilities and geochemical associations in soil compartments as based on using the three step BCR (now...... the Measurements and Testing Programme of the European Commission) sequential extraction scheme. Employing a peristaltic pump as liquid driver, alternate directional flows of the extractants are used to overcome compression of the solid particles within the extraction unit to ensure a steady partitioning flow rate...... and thus to maintain constant operationally defined extraction conditions. The proposed flow set-up is proven to allow for trouble-free handling of soil samples up to 1 g and flow rates ≤ 10 mL min–1. The miniaturized extraction system was coupled to ICP-MS through a flow injection interface in order...

  10. Metal-organic framework MIL-101 as sorbent based on double-pumps controlled on-line solid-phase extraction coupled with high-performance liquid chromatography for the determination of flavonoids in environmental water samples.

    Science.gov (United States)

    Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang

    2016-10-01

    A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Effects of push/pull perfusion and ultrasonication on the extraction efficiencies of phthalate esters in sports drink samples using on-line hollow-fiber liquid-phase microextraction.

    Science.gov (United States)

    Chao, Yu-Ying; Lee, Chien-Hung; Chien, Tzu-Yang; Shih, Yu-Hsuan; Lu, Yin-An; Kuo, Ting-Hsuan; Huang, Yeou-Lih

    2013-08-28

    In previous studies, we developed a process, on-line ultrasound-assisted push/pull perfusion hollow-fiber liquid-phase microextraction (UA-PPP-HF-LPME), combining the techniques of push/pull perfusion (PPP) and ultrasonication with hollow-fiber liquid-phase microextraction (HF-LPME), to achieve rapid extraction of acidic phenols from water samples. In this present study, we further evaluated three more-advanced and novel effects of PPP and ultrasonication on the extraction efficiencies of neutral high-molecular-weight phthalate esters (HPAEs) in sports drinks. First, we found that inner-fiber fluid leakage occurs only in push-only perfusion-based and pull-only perfusion-based HF-LPME, but not in the PPP mode. Second, we identified a significant negative interaction between ultrasonication and temperature. Third, we found that the extraction time of the newly proposed system could be shortened by more than 93%. From an investigation of the factors affecting UA-PPP-HF-LPME, we established optimal extraction conditions and achieved acceptable on-line enrichment factors of 92-146 for HPAEs with a sampling time of just 2 min.

  12. Biomass pretreatment

    Science.gov (United States)

    Hennessey, Susan Marie; Friend, Julie; Elander, Richard T; Tucker, III, Melvin P

    2013-05-21

    A method is provided for producing an improved pretreated biomass product for use in saccharification followed by fermentation to produce a target chemical that includes removal of saccharification and or fermentation inhibitors from the pretreated biomass product. Specifically, the pretreated biomass product derived from using the present method has fewer inhibitors of saccharification and/or fermentation without a loss in sugar content.

  13. On-line filtering

    International Nuclear Information System (INIS)

    Verkerk, C.

    1978-01-01

    Present day electronic detectors used in high energy physics make it possible to obtain high event rates and it is likely that future experiments will face even higher data rates than at present. The complexity of the apparatus increases very rapidly with time and also the criteria for selecting desired events become more and more complex. So complex in fact that the fast trigger system cannot be designed to fully cope with it. The interesting events become thus contaminated with multitudes of uninteresting ones. To distinguish the 'good' events from the often overwhelming background of other events one has to resort to computing techniques. Normally this selection is made in the first part of the analysis of the events, analysis normally performed on a powerful scientific computer. This implies however that many uninteresting or background events have to be recorded during the experiment for subsequent analysis. A number of undesired consequences result; and these constitute a sufficient reason for trying to perform the selection at an earlier stage, in fact ideally before the events are recorded on magnetic tape. This early selection is called 'on-line filtering' and it is the topic of the present lectures. (Auth.)

  14. Synthesis and application of chloromethylated polystyrene modified with 1-phenyl-1,2-propanedione-2-oxime thiosemicarbazone (PPDOT) as a new sorbent for the on-line preconcentration and determination of copper in water, soil, and food samples by FAAS

    Energy Technology Data Exchange (ETDEWEB)

    Chamjangali, Mansour Arab, E-mail: marab@shahroodut.ac.ir [College of Chemistry, Shahrood University of Technology, P.O. Box 36155-316, Shahrood (Iran, Islamic Republic of); Bagherian, Ghadamali; Mokhlesian, Ali; Bahramian, Bahram [College of Chemistry, Shahrood University of Technology, P.O. Box 36155-316, Shahrood (Iran, Islamic Republic of)

    2011-09-15

    Highlights: {yields} This paper is the first report on the use of PS-PPDOT resin in the SPE studies. {yields} The proposed adsorbent is highly selective for trace determination of copper. {yields} The method is applicable for copper determination in water, soil, and food samples. - Abstract: In this paper, we report a simple and sensitive on-line solid phase extraction system for the preconcentration and determination of Cu(II) by flame atomic absorption spectrometry (FAAS). This method is based upon the on-line retention of copper at pH 5.0 on a minicolumn packed with chloromethylated polystyrene modified by 1-phenyl-1,2-propanedione-2-oxime thiosemicarbazone (PPDOT) as a new solid-phase extraction (SPE) sorbent. The retained Cu(II) ions were eluted with 1.0 M HNO{sub 3}, and transported directly to FAAS for determination. Several chemical and flow variables were studied and optimized for a quantitative preconcentration and determination of copper(II). At the optimized conditions, for preconcentration of 10.0 mL of a sample solution, a linear calibration graph was obtained over the concentration range of 3.00-120.0 {mu}g L{sup -1} for Cu(II). The limit of detection (3{sigma}), limit of quantification (10{sigma}), and enrichment factor are 0.56 {mu}g L{sup -1}, 2.0 {mu}g L{sup -1} and 41, respectively. The relative standard deviation (n = 6) at 20 {mu}g L{sup -1} of Cu(II) is 2.0%. This method could be applied for determination of trace amounts of Cu(II) in water, soil, and food samples with satisfactory results.

  15. A simple and highly sensitive on-line column extraction liquid chromatography-tandem mass spectrometry method for the determination of protein-unbound tacrolimus in human plasma samples.

    Science.gov (United States)

    Bittersohl, Heike; Schniedewind, Björn; Christians, Uwe; Luppa, Peter B

    2018-04-27

    Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP ® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Synthesis and application of chloromethylated polystyrene modified with 1-phenyl-1,2-propanedione-2-oxime thiosemicarbazone (PPDOT) as a new sorbent for the on-line preconcentration and determination of copper in water, soil, and food samples by FAAS

    International Nuclear Information System (INIS)

    Chamjangali, Mansour Arab; Bagherian, Ghadamali; Mokhlesian, Ali; Bahramian, Bahram

    2011-01-01

    Highlights: → This paper is the first report on the use of PS-PPDOT resin in the SPE studies. → The proposed adsorbent is highly selective for trace determination of copper. → The method is applicable for copper determination in water, soil, and food samples. - Abstract: In this paper, we report a simple and sensitive on-line solid phase extraction system for the preconcentration and determination of Cu(II) by flame atomic absorption spectrometry (FAAS). This method is based upon the on-line retention of copper at pH 5.0 on a minicolumn packed with chloromethylated polystyrene modified by 1-phenyl-1,2-propanedione-2-oxime thiosemicarbazone (PPDOT) as a new solid-phase extraction (SPE) sorbent. The retained Cu(II) ions were eluted with 1.0 M HNO 3 , and transported directly to FAAS for determination. Several chemical and flow variables were studied and optimized for a quantitative preconcentration and determination of copper(II). At the optimized conditions, for preconcentration of 10.0 mL of a sample solution, a linear calibration graph was obtained over the concentration range of 3.00-120.0 μg L -1 for Cu(II). The limit of detection (3σ), limit of quantification (10σ), and enrichment factor are 0.56 μg L -1 , 2.0 μg L -1 and 41, respectively. The relative standard deviation (n = 6) at 20 μg L -1 of Cu(II) is 2.0%. This method could be applied for determination of trace amounts of Cu(II) in water, soil, and food samples with satisfactory results.

  17. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  18. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  19. On-line preconcentration using a resin functionalized with 3,4-dihydroxybenzoic acid for the determination of trace elements in biological samples by thermospray flame furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Lemos, Valfredo A.; Bezerra, Marcos A.; Amorim, Fabio A.C.

    2008-01-01

    In the present paper, an on-line preconcentration procedure for determination of cadmium, copper and zinc by thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) is proposed. Amberlite XAD-4 functionalized with 3,4-dihydroxybenzoic acid (XAD4-DHB) packed in a minicolumn was used as sorbent material. The metals were retained on the XAD-DHB resin, from which it could be eluted directly to the thermospray flame furnace system. The detection limits were 28 (Cd), 100 (Cu) and 77 ng L -1 (Zn) for 60 s preconcentration time, at a sample flow rate of 7.0 mL min -1 . Enrichment factors were 102, 91 and 62, for cadmium, copper and zinc, respectively. The procedure has been applied successfully to metal determination in biological standard reference materials

  20. Coupling on-line preconcentration by ion-exchange with ETAAS. A novel flow injection approach based on the use of a renewable microcolumn as demonstrated for the determination of nickel in environmental and biological samples

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2000-01-01

    microcolumn incorporated within an integrated micro FI-system, the column is loaded with a defined volume of small beads of an SP Sephadex C-25 cation-exchange resin and subsequently exposed to a metered amount of sample solution. However, instead of eluting the retained analyte from the organic ion-exchange......A novel way of exploiting flow injection/sequential injection (FIA/SIA) on-line ion-exchange preconcentration with detection by electrothermal atomic absorption spectrometry (ETAAS) is described and demonstrated for the determination of trace-levels of nickel. Based on the use of a renewable...... resin, the beads are along with 30 mul of carrier (buffer) solution transported via air segmentation directly into the graphite tube, where they are ashed during the pyrolysis and atomization process. The ETAAS determination is performed in parallel with the preconcentration process of the ensuing...

  1. On-line moisture analysis

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Mijak, D.G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk material. Nuclear-based analysers measure the total hydrogen content in the sample and do not differentiate between free and combined moisture. Such analysers may also be sensitive to material presentation and elemental composition. Very low frequency electromagnetic probes, such as capacitance or conductance probes, operate in the frequency region where the DC conductivity dominates much of the response, which is a function not only of moisture content but also of ionic composition and chemistry. These problems are overcome using microwave transmission techniques, which also have the following advantages, as a true bulk moisture analysis is obtained, because a high percentage of the bulk material is analysed; the moisture estimate is mostly insensitive to any biased presentation of moisture, for example due to stratification of bulk material with different moisture content and because no physical contact is made between the sensor and the bulk material. This is

  2. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    Purpose/Objective: The purpose of this presentation is to review the physics of imaging with high energy x-ray beams; examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine errors in patient positioning quantitatively; and discuss some of the ways that portal imaging has been incorporated into routine clinical practice. Verification of patient positioning has always been an important aspect of external beam radiation therapy. Checks of patient positioning have generally been done with film, however, film suffers from a number of drawbacks, such as poor image display and delays due to film development. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems, which are intended to overcome the limitations of portal films. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The fundamental factors which limit image quality and the characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same

  3. ESR-based Identification of Radiation-Induced Free Radicals in Gamma-Irradiated Basil and Clove Using Different Sample Pre-Treatments

    International Nuclear Information System (INIS)

    Kwak, J.Y.; Ahn, J.J.; Kashif Akram; Kwon, J.H.

    2012-01-01

    An improved detection of radiation-induced paramagnetic faults was developed to identify the irradiation status of basil and clove. The effectiveness of different sample pretreatments, including freeze-drying (FD), oven-drying (OD), alcoholic-extraction (AE), and water-washing and alcoholic-extraction (WAE), were examined. All non-irradiated samples showed a single central signal (g 0 = 2.006), whereas radicals representing two additional side peaks (g 1 = 2.023 and g 2 = 1.986) with a mutual distance of 6 mT were detected in the irradiated samples. AE and WAE produced the best results for irradiated clove in terms of intensities of radiation-specific ESR signals and their ratios to the central signal. However, FD provided the highest intensities of radiation-specific ESR signals for basil, whereas their ratios to the major signal were better in the cases of AE and WAE. Signal noise, particularly due to Mn 2+ signals, was observed, whereas it decreased in AE and WAE pretreatments. Based on our results, AE and WAE can improve the detection conditions for radiation-specific ESR signals in irradiated samples. (author)

  4. Evaporation, Rheology, And Vitrification Of A Pretreated Radioactive Hanford Tank 241-AN-104 Sample Mixed With Simulated Law SBS Recycle

    International Nuclear Information System (INIS)

    MARK, CROWDER

    2004-01-01

    This study involved evaporation of the radioactive low activity waste AN-104 pretreated waste and a simulant LAW submerged bed scrubber recycle from Duratek blended at two different volume ratios. The AN104SBS35651 pretreated wastes were then blended with glass former chemicals, GFCs, and a single blend vitrified. The chemical and physical properties, during all phases of blending were characterized per Table 1-1. The AN-104 radioactive waste used for this study was initially characterized at SRNL, Hay 2003, followed by filtration to remove entrained solids, Poirier 2003, and put through ion exchange for cesium removal, Adu-Wusu 2003,. All the test objectives in Table 1-1 are from section 3 of the Test Specification, Sidibe 2003. The test exception listed in Table 1-2 deleted the vitrification objectives for vitrification product analyses and product testing of the AN-104 glass. Therefore, Table 1-1 does not list any vitrification product analyses and product testing objectives

  5. Use of alkaline or enzymatic sample pretreatment prior to characterization of gold nanoparticles in animal tissue by single-particle ICPMS

    DEFF Research Database (Denmark)

    Löschner, Katrin; Brabrand, Myung Suk Jung; Sloth, Jens Jørgen

    2014-01-01

    , not much is known about the applicability of spICPMS for determination of NPs in complex matrices such as biological tissues. In the present study, alkaline and enzymatic treatments were applied to solubilize spleen samples from rats, which had been administered 60-nm gold nanoparticles (Au......NPs) intravenously. The results showed that similar size distributions of AuNPs were obtained independent of the sample preparation method used. Furthermore, the quantitative results for AuNP mass concentration obtained with spICPMS following alkaline sample pretreatment coincided with results for total gold...... concentration obtained by conventional ICPMS analysis of acid-digested tissue. The recovery of AuNPs from enzymatically digested tissue, however, was approximately four times lower. Spiking experiments of blank spleen samples with AuNPs showed that the lower recovery was caused by an inferior transport...

  6. Toxoplasma gondii and pre-treatment protocols for polymerase chain reaction analysis of milk samples: a field trial in sheep from Southern Italy

    Directory of Open Access Journals (Sweden)

    Alice Vismarra

    2017-02-01

    Full Text Available Toxoplasmosis is a zoonotic disease caused by the protozoan Toxoplasma gondii. Ingestion of raw milk has been suggested as a risk for transmission to humans. Here the authors evaluated pre-treatment protocols for DNA extraction on T. gondii tachyzoite-spiked sheep milk with the aim of identifying the method that resulted in the most rapid and reliable polymerase chain reaction (PCR positivity. This protocol was then used to analyse milk samples from sheep of three different farms in Southern Italy, including real time PCR for DNA quantification and PCR-restriction fragment length polymorphism for genotyping. The pre-treatment protocol using ethylenediaminetetraacetic acid and Tris-HCl to remove casein gave the best results in the least amount of time compared to the others on spiked milk samples. One sample of 21 collected from sheep farms was positive on one-step PCR, real time PCR and resulted in a Type I genotype at one locus (SAG3. Milk usually contains a low number of tachyzoites and this could be a limiting factor for molecular identification. Our preliminary data has evaluated a rapid, cost-effective and sensitive protocol to treat milk before DNA extraction. The results of the present study also confirm the possibility of T. gondii transmission through consumption of raw milk and its unpasteurised derivatives.

  7. Investigating effects of sample pretreatment on protein stability using size-exclusion chromatography and high-resolution continuum source atomic absorption spectrometry.

    Science.gov (United States)

    Rakow, Tobias; El Deeb, Sami; Hahne, Thomas; El-Hady, Deia Abd; AlBishri, Hassan M; Wätzig, Hermann

    2014-09-01

    In this study, size-exclusion chromatography and high-resolution atomic absorption spectrometry methods have been developed and evaluated to test the stability of proteins during sample pretreatment. This especially includes different storage conditions but also adsorption before or even during the chromatographic process. For the development of the size exclusion method, a Biosep S3000 5 μm column was used for investigating a series of representative model proteins, namely bovine serum albumin, ovalbumin, monoclonal immunoglobulin G antibody, and myoglobin. Ambient temperature storage was found to be harmful to all model proteins, whereas short-term storage up to 14 days could be done in an ordinary refrigerator. Freezing the protein solutions was always complicated and had to be evaluated for each protein in the corresponding solvent. To keep the proteins in their native state a gentle freezing temperature should be chosen, hence liquid nitrogen should be avoided. Furthermore, a high-resolution continuum source atomic absorption spectrometry method was developed to observe the adsorption of proteins on container material and chromatographic columns. Adsorption to any container led to a sample loss and lowered the recovery rates. During the pretreatment and high-performance size-exclusion chromatography, adsorption caused sample losses of up to 33%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Characterization and Identification of Gamma-Irradiated Kimchi Cabbage and Broccoli by Electron Spin Resonance Spectroscopy using Different Sample Pre-treatments

    International Nuclear Information System (INIS)

    Kwak, J.Y.; Ahn, J.J.; Kashif Akram; Kim, G.R.; Kwon, J.H.

    2012-01-01

    Electron spin resonance (ESR) spectroscopy of gamma-irradiated fresh broccoli and kimchi cabbage was conducted to identify their irradiation history. Different pretreatments, such as freeze-drying (FD), oven-drying (OD), alcoholic-drying (ALD), and water-washing and alcoholic-drying (WAD) were used to lower the moisture contents of the samples prior to ESR analysis. The non-irradiated samples exhibited a single central signal (g 0 = 2.0007) with clear effect of Mn 2+ , especially in kimchi cabbage. Upon irradiation, there was an increase in the intensity of the central signal, and two side peaks, mutually spaced at 6 mT, were also observed. These side peaks with g 1 (left) = 2.023 and g 2 (right) = 1.985 were attributed to radiation-induced cellulose radicals. Leaf and stem in broccoli, and root and stem in kimchi cabbage provided good ESR signal responses upon irradiation. The signal noise was reduced in case of ALD and WAD pretreatments, particularly due to Mn 2+ signals. The ALD treatment was found most feasible to detect the improved ESR spectra in the irradiated samples. (author)

  9. An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

    Science.gov (United States)

    van Staden, J F; Mashamba, Mulalo G; Stefan, Raluca I

    2002-09-01

    An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

  10. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H; Saerme, T; Kotiaho, T; Hiissa, T; Savolahti, P; Komppa, V [VTT Chemical Technology, Espoo (Finland)

    1999-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  11. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H.; Saerme, T.; Kotiaho, T.; Hiissa, T.; Savolahti, P.; Komppa, V. [VTT Chemical Technology, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  12. Automated gravimetric sample pretreatment using an industrial robot for the high-precision determination of plutonium by isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Surugaya, Naoki; Hiyama, Toshiaki; Watahiki, Masaru

    2008-01-01

    A robotized sample-preparation method for the determination of Pu, which is recovered by extraction reprocessing of spent nuclear fuel, by isotope dilution mass spectrometry (IDMS) is described. The automated system uses a six-axis industrial robot, whose motility is very fast, accurate, and flexible, installed in a glove box. The automation of the weighing and dilution steps enables operator-unattended sample pretreatment for the high-precision analysis of Pu in aqueous solutions. Using the developed system, the Pu concentration in a HNO 3 medium was successfully determined using a set of subsequent mass spectrometric measurements. The relative uncertainty in determining the Pu concentration by IDMS using this system was estimated to be less than 0.1% (k=2), which is equal to that expected of a talented analysis. The operation time required was the same as that for a skilled operator. (author)

  13. Determination of antibiotic compounds in water by on-line SPE-LC/MSD.

    Science.gov (United States)

    Choi, Keun-Joo; Kim, Sang-Goo; Kim, Chang-won; Kim, Seung-Hyun

    2007-01-01

    This study attempts to provide an improved approach for the analysis of antibiotics, which normally exist at low concentration in complex matrices such as receiving streams of wastewater treatment plant discharge. The analytical method developed in this study combines an existing pretreatment technique of solid-phase extraction (SPE) with liquid chromatography mass spectrometry (LC/MSD) through on-line connection. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 ml water samples, recoveries were between 74.3% and 116.5% and average LOQ was 0.11 microg l(-1) for the sulfonamide antibiotics (SA) and 0.09 microg l(-1) for the tetracycline antibiotics (TA). Application of the developed method for the analysis of fourteen antibiotics revealed that several antibiotics were detected at concentrations above the LOQ in ARW. Treated and untreated sewage and agricultural wastewater were mostly responsible for the antibiotics contamination of the river. Antibiotics were detected at much higher concentrations in the agricultural wastewater sample than in the sewage sample, implying substantial use of antibiotics in the agricultural industry. Wastewater treatment was generally effective in separation of the antibiotics tested in this study. The extent of the treatment depended on the type of antibiotics. Hydrophobic antibiotics were more effectively separated from the solution than hydrophilic antibiotics.

  14. Heparin removal by ecteola-cellulose pre-treatment enables the use of plasma samples for accurate measurement of anti-Yellow fever virus neutralizing antibodies.

    Science.gov (United States)

    Campi-Azevedo, Ana Carolina; Peruhype-Magalhães, Vanessa; Coelho-Dos-Reis, Jordana Grazziela; Costa-Pereira, Christiane; Yamamura, Anna Yoshida; Lima, Sheila Maria Barbosa de; Simões, Marisol; Campos, Fernanda Magalhães Freire; de Castro Zacche Tonini, Aline; Lemos, Elenice Moreira; Brum, Ricardo Cristiano; de Noronha, Tatiana Guimarães; Freire, Marcos Silva; Maia, Maria de Lourdes Sousa; Camacho, Luiz Antônio Bastos; Rios, Maria; Chancey, Caren; Romano, Alessandro; Domingues, Carla Magda; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis

    2017-09-01

    Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Improvements of the Vis-NIRS Model in the Prediction of Soil Organic Matter Content Using Spectral Pretreatments, Sample Selection, and Wavelength Optimization

    Science.gov (United States)

    Lin, Z. D.; Wang, Y. B.; Wang, R. J.; Wang, L. S.; Lu, C. P.; Zhang, Z. Y.; Song, L. T.; Liu, Y.

    2017-07-01

    A total of 130 topsoil samples collected from Guoyang County, Anhui Province, China, were used to establish a Vis-NIR model for the prediction of organic matter content (OMC) in lime concretion black soils. Different spectral pretreatments were applied for minimizing the irrelevant and useless information of the spectra and increasing the spectra correlation with the measured values. Subsequently, the Kennard-Stone (KS) method and sample set partitioning based on joint x-y distances (SPXY) were used to select the training set. Successive projection algorithm (SPA) and genetic algorithm (GA) were then applied for wavelength optimization. Finally, the principal component regression (PCR) model was constructed, in which the optimal number of principal components was determined using the leave-one-out cross validation technique. The results show that the combination of the Savitzky-Golay (SG) filter for smoothing and multiplicative scatter correction (MSC) can eliminate the effect of noise and baseline drift; the SPXY method is preferable to KS in the sample selection; both the SPA and the GA can significantly reduce the number of wavelength variables and favorably increase the accuracy, especially GA, which greatly improved the prediction accuracy of soil OMC with Rcc, RMSEP, and RPD up to 0.9316, 0.2142, and 2.3195, respectively.

  16. Implementation of suitable flow injection/sequential injection on-line sample pretreatment schemes. Separation and preconcentration procedures for the determination of trace metal concentrations by ETAAS and/or ICPMS

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Wang, Jianhua

    are feasible, such as liquid-liquid extraction, (co)precipitation with collection in knotted reactors, adsorption, hydride generation, or the use of ion-exchange columns. Apart from hydride generation, where the analyte is converted into a gaseous species, the common denominator for these approaches...

  17. Optimizing sample pretreatment for compound-specific stable carbon isotopic analysis of amino sugars in marine sediment

    Science.gov (United States)

    Zhu, R.; Lin, Y.-S.; Lipp, J. S.; Meador, T. B.; Hinrichs, K.-U.

    2014-09-01

    Amino sugars are quantitatively significant constituents of soil and marine sediment, but their sources and turnover in environmental samples remain poorly understood. The stable carbon isotopic composition of amino sugars can provide information on the lifestyles of their source organisms and can be monitored during incubations with labeled substrates to estimate the turnover rates of microbial populations. However, until now, such investigation has been carried out only with soil samples, partly because of the much lower abundance of amino sugars in marine environments. We therefore optimized a procedure for compound-specific isotopic analysis of amino sugars in marine sediment, employing gas chromatography-isotope ratio mass spectrometry. The whole procedure consisted of hydrolysis, neutralization, enrichment, and derivatization of amino sugars. Except for the derivatization step, the protocol introduced negligible isotopic fractionation, and the minimum requirement of amino sugar for isotopic analysis was 20 ng, i.e., equivalent to ~8 ng of amino sugar carbon. Compound-specific stable carbon isotopic analysis of amino sugars obtained from marine sediment extracts indicated that glucosamine and galactosamine were mainly derived from organic detritus, whereas muramic acid showed isotopic imprints from indigenous bacterial activities. The δ13C analysis of amino sugars provides a valuable addition to the biomarker-based characterization of microbial metabolism in the deep marine biosphere, which so far has been lipid oriented and biased towards the detection of archaeal signals.

  18. Tar formation in a steam-O2 blown CFB gasifier and a steam blown PBFB gasifier (BabyHPR) : Comparison between different on-line measurement techniques and the off-line SPA sampling and analysis method

    NARCIS (Netherlands)

    Meng, X.; Mitsakis, P.; Mayerhofen, M.; De Jong, W.; Gaderer, M.; Verkooijen, A.H.M.; Spliethoff, H.

    2012-01-01

    Two on-line tar measurement campaigns were carried out using an atmospheric pressure 100 “”kWth steam-O2 blown circulating fluidized bed (CFB) gasifier at the Delft University of Technology (TUD) and a 30–40kWth steam blown pressurized bubbling fluidized bed (PBFB) gasifier BabyHPR (Heatpipe

  19. CERN Video News on line

    CERN Multimedia

    2003-01-01

    The latest CERN video news is on line. In this issue : an interview with the Director General and reports on the new home for the DELPHI barrel and the CERN firemen's spectacular training programme. There's also a vintage video news clip from 1954. See: www.cern.ch/video or Bulletin web page

  20. Ethanol production from lignocellulosic materials. Fermentation and on-line analysis

    Energy Technology Data Exchange (ETDEWEB)

    Olsson, L.

    1994-04-01

    The fermentation performance of bacteria, yeast and fungi was investigated in lignocellulosic hydrolysates with the aim of finding microorganisms which both withstand the inhibitors and that have the ability to ferment pentoses. Firstly, the performance of Saccharomyces cidri, Saccharomyces cerevisiae, Lactobacillus brevis, Lactococcus lactis ssp lactis, Escherichia coli and Zymomonas mobilis was investigated in spent sulphite liquor and enzymatic hydrolysate of steam-pretreated willow. Secondly, the performance of natural and recombinant E. coli, Pichia stipitis, recombinant S. cerevisiae, S. cerevisiae in combination with xylose isomerase and Fusarium oxysporum was investigated in a xylose-rich acid hydrolysate of corn cob. Recombinant E. coli was the best alternative for fermentation of lignocellulosic hydrolysates, giving both high yields and productivities. The main drawback was that detoxification was necessary. The kinetics of the fermentation with recombinant E. coli KO11 was investigated in the condensate of steam-pretreated willow. A cost analysis of the ethanol production from willow was made, which predicted an ethanol production cost of 3.9 SEK/l for the pentose fermentation. The detoxification cost constituted 22% of this cost. The monitoring of three monosaccharides and ethanol in lignocellulosic hydro lysates is described. The monosaccharides were determined using immobilized pyranose oxidase in an on-line amperometric analyser. Immobilization and characterization of pyranose oxidase from Phanerochaete chrysosporium is also described. The ethanol was monitored on-line using a micro dialysis probe as an in situ sampling device. The dialysate components were then separated in a column liquid chromatographic system and the ethanol was selectively detected by an amperometric alcohol bio sensor. The determinations with on-line analysis methods agreed well with off-line methods. 248 refs, 4 figs, 12 tabs

  1. Does the pretreatment tumor sampling location correspond with metabolic activity on 18F-FDG PET/CT in breast cancer patients scheduled for neoadjuvant chemotherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Koolen, Bas B., E-mail: b.koolen@nki.nl [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Elshof, Lotte E. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vrancken Peeters, Marie-Jeanne T.F.D. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vogel, Wouter V. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Valdés Olmos, Renato A. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands)

    2013-12-01

    Purpose: To define the correlation between the core biopsy location and the area with highest metabolic activity on 18F-FDG PET/CT in stage II–III breast cancer patients before neoadjuvant chemotherapy. Also, we would like to select a subgroup of patients in which PET/CT information may optimize tumor sampling. Methods: A PET/CT in prone position was acquired in 199 patients with 203 tumors. The distance and relative difference in standardized uptake value (SUV) between core biopsy localization (indicated by a marker) and area with highest degree of FDG uptake were evaluated. A distance ≥2 cm and a relative difference in SUV ≥25% were considered clinically relevant and a combination of both was defined as non-correspondence. Non-correspondence for different tumor characteristics (TNM stage, lesion morphology on MRI and PET/CT, histology, subtype, grade, and Ki-67) was assessed. Results: Non-correspondence was found in 28 (14%) of 203 tumors. Non-correspondence was significantly associated with T-stage, lesion morphology on MRI and PET/CT, tumor diameter, and histologic type. It was more often seen in tumors with a higher T-stage (p = 0.028), diffuse (non-mass) and multifocal tumors on MRI (p = 0.001), diffuse and multifocal tumors on PET/CT (p < 0.001), tumors >3 cm (p < 0.001), and lobular carcinomas (p < 0.001). No association was found with other features. Conclusion: Non-correspondence between the core biopsy location and area with highest FDG uptake is regularly seen in stage II–III breast cancer patients. PET/CT information and possibly FDG-guided biopsies are most likely to improve pretreatment tumor sampling in tumors >3 cm, lobular carcinomas, and diffuse and multifocal tumors.

  2. On line ultrasonic integrated backscatter

    International Nuclear Information System (INIS)

    Landini, L.; Picano, E.; Mazzarisi, A.; Santarelli, F.; Benassi, A.; De Pieri, G.

    1988-01-01

    A new equipment for on-line evaluation of index based on two-dimensional integrated backscatter from ultrasonic images is described. The new equipment is fully integrated into a B-mode ultrasonic apparatus which provides a simultaneous display of conventional information together with parameters of tissue characterization. The system has been tested with a backscattering model of microbubbles in polysaccharide solution, characterized by a physiological exponential time decay. An exponential fitting to the experimental data was performed which yielded r=0.95

  3. On-line nuclear orientation

    International Nuclear Information System (INIS)

    Krane, K.S.

    1990-01-01

    This grant has as its overall goal the pursuit of on-line nuclear orientation experiments for the purpose of eliciting details of nuclear structure from the decays of neutron-deficient nuclei, such as those produced by the Holifield Heavy-Ion Research Facility at Oak Ridge and extracted by the UNISOR Isotope Separator. This paper discusses: refrigerator development; the decay of 184 Au; the decay of 191 Hg to 191 Au; the decay of 189 Pt to 189 Ir; the decays of 109,111 Pd; the decay of 172 Er; and solid angle corrections

  4. Collection, pre-treatment and analyses of Cs-137 and Tc-99 in marine samples at the Institute of Marine Research (IMR), Norway

    International Nuclear Information System (INIS)

    Heldal, H.E.

    2010-01-01

    Full text: The Institute of Marine Research (IMR) is an important contributor to the Norwegian marine monitoring programme RAME (Radioactivity in the Marine Environment). RAME is funded by the Ministry of the Environment and coordinated by the Norwegian Radiation Protection Authority (NRPA). Sample collection is performed from IMRs research vessels in the open sea areas of the North-, Norwegian- and Barents Seas and in Norwegian fjords. The samples consist of biota (fish and other marine organisms), sediments and seawater. Biota samples are frozen onboard the ship and transported to IMR where the samples are subsequently ground up, freeze dried, homogenized and aliquoted into polyethylene counting boxes of appropriate size prior to analysis. Attempts are made to collect filets from 25 fish for each sample of large fish such as cod, haddock, saithe, red-fish and Greenland halibut. For smaller fish (e.g. blue whiting, polar cod, capelin and Atlantic herring) and other organisms such as amphipods, krill, and deep-sea shrimps, a sample of 2-3 kg of each species is taken. These samples are ground up whole. Sediment samples are collected using a Smoegen boxcorer, from where both surface samples and cores are taken. The samples are frozen onboard the ship. While half-frozen, the cores are cut into slices of 1 or 2 cm thickness on board the ship, then frozen again and transported to IMR where they are treated as described above for the biota samples. Large volumes (typically 50-200 L) of seawater are needed in order to get enough material for analysis. Pre-treatment of the samples in the field is therefore an advantage. Surface samples (5 m) of seawater are collected from a shipboard pump, while a CTD-rosette multi-bottle sampler with 12 10 L samplers is used to collect seawater from depths below 5 meters. For the analysis of Cs-137, Cu 2 [Fe(CN) 6 ]-impregnated cotton filters are used for the pre-concentration. One pre-filter without impregnation, two Cu 2 [Fe(CN) 6

  5. Graphene oxide-based composite monolith as new sorbent for the on-line solid phase extraction and high performance liquid chromatography determination of ß-sitosterol in food samples.

    Science.gov (United States)

    Cui, Beijiao; Guo, Bin; Wang, Huimin; Zhang, Doudou; Liu, Haiyan; Bai, Ligai; Yan, Hongyuan; Han, Dandan

    2018-08-15

    A composite monolithic column was prepared by redox initiation method for the on-line purification and enrichment of β-sitosterol, in which graphene oxide (GO) was embedded. The obtained monolithic column was characterized by scanning electron microscopy (SEM) and nitrogen adsorption-desorption isotherm measurement, which indicated that the monolith possessed characteristics of porous structure and high permeability. Under the optimum conditions for extraction and determination, the calibration equation was y = 47.92 × -0.1391; the linear range was 0.008-1.0 mg mL -1 ; the linear regression coefficient was 0.998; the limit of detection (LOD) is 2.4 μg mL -1 ; the limit of quantitation (LOQ) was 8 μg mL -1 ; precisions for intra-day and inter-day assays presented as relative standard deviations were less than 4.3% and 6.8%, respectively. Under the selective conditions, the enrichment factor of the method was 119. The recovery was in the range of 80.40-98.00%. Moreover, the adsorption amount of the monolith was compared with silica gel-C18 adsorbent and the monolith without graphene oxide being embedded. The polymerization monolithic column showed high selectivity and good permeability, and it was successfully used as on-line solid-phase extraction (SPE) column for determination of β-sitosterol in edible oil. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Square-wave anodic-stripping voltammetric determination of Cd, Pb and Cu in wine: Set-up and optimization of sample pre-treatment and instrumental parameters

    International Nuclear Information System (INIS)

    Illuminati, Silvia; Annibaldi, Anna; Truzzi, Cristina; Finale, Carolina; Scarponi, Giuseppe

    2013-01-01

    For the first time, square-wave anodic-stripping voltammetry (SWASV) was set up and optimized for the determination of Cd, Pb and Cu in white wine after UV photo-oxidative digestion of the sample. The best procedure for the sample pre-treatment consisted in a 6-h UV irradiation of diluted, acidified wine, with the addition of ultrapure H 2 O 2 (three sequential additions during the irradiation). Due to metal concentration differences, separate measurements were carried out for Cd (deposition potential −950 mV vs. Ag/AgCl/3 M KCl deposition time 15 min) and simultaneously for Pb and Cu (E d −750 mV, t d 30 s). The optimum set-up of the main instrumental parameters, evaluated also in terms of the signal-to-noise ratio, were as follows: E SW 20 mV, f 100 Hz, ΔE step 8 mV, t step 100 ms, t wait 60 ms, t delay 2 ms, t meas 3 ms. The electrochemical behaviour was reversible bielectronic for Cd and Pb, and kinetically controlled monoelectronic for Cu. Good accuracy was found both when the recovery procedure was used and when the results were compared with data obtained by differential pulse anodic stripping voltammetry. The linearity of the response was verified up to ∼4 μg L −1 for Cd and Pb and ∼15 μg L −1 for Cu. The detection limits for t d = 5 min in the 10 times diluted, UV digested sample were (ng L −1 ): Cd 7.0, Pb 1.2 and Cu 6.6, which are well below currently applied methods. Application to a Verdicchio dei Castelli di Jesi white wine revealed concentration levels of Cd ∼0.2, Pb ∼10, Cu ∼30 μg L −1 with repeatabilities of (±RSD%) Cd ±6%, Pb ±5%, Cu ±10%

  7. On-line and bulk analysis for the resource industries

    International Nuclear Information System (INIS)

    Lim, C.S.; Sowerby, B.D.; Tickner, J.R.; Madsen, I.C.

    2001-01-01

    Nuclear techniques are the basis of many CSIRO on-line and bulk analysis systems that are now widely used in the mineral and energy industries. The continuous analysis and rapid response of these systems have led to improved control of mining, processing and blending operations. This paper reviews recent developments in neutron, gamma-ray and X-ray techniques for on-line and bulk analysis by CSIRO Minerals including neutron techniques for the on-conveyor belt determination of the composition of cement raw meal, the on-line analysis of composition in pyrometallurgical applications, the on-conveyor belt determination of ash in coal, and the rapid and accurate determination of gold in bulk laboratory samples. The paper also discusses a new gamma-ray technique for the on-line determination of ash in coal and the application of X-ray diffraction techniques for the on-line determination of mineralogy in the cement industry

  8. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  9. On-line neutron activation analyzers

    International Nuclear Information System (INIS)

    Flahaut, V.; Colmon, A.

    1999-01-01

    A neutronic analyser has been designed to determine the composition of the flow of raw materials entering a cement factory on the conveyor belt. This new system gives a reliable analysis of the whole cargo that outdates the sampling or the usual surface analysis based on fluorescence spectrometry. The accuracy is about 1%.The neutrons interact with the materials on an average depth of 25 cm and are absorbed by nuclei, these nuclei produce photons whose energy is characteristic of the chemical element itself. The composition can be deduced by measuring the number of photons emitted and their energy. The analysis is made on-line and can concern the search for about 10 compounds. In the case of cement the list of compounds is: SiO 2 , CaO, Al 2 O 3 , Fe 2 O 3 , MgO, Na 2 O, TiO 2 , S, Mn 2 O 3 , K 2 O, and H 2 O. The neutron generator involves a deuterium ion source whose deuterium ions are accelerated by means of an electrical field and impinge on a tritiated target, the nuclear reactions between deuterium and tritium produce 14 MeV neutrons. This neutron analysing technique can be adapted to any need of on-line composition determination. (A.C.)

  10. Focusing and non-focusing modulation strategies for the improvement of on-line two-dimensional hydrophilic interaction chromatography × reversed phase profiling of complex food samples.

    Science.gov (United States)

    Montero, Lidia; Ibáñez, Elena; Russo, Mariateresa; Rastrelli, Luca; Cifuentes, Alejandro; Herrero, Miguel

    2017-09-08

    Comprehensive two-dimensional liquid chromatography (LC × LC) is ever gaining interest in food analysis, as often, food-related samples are too complex to be analyzed through one-dimensional approaches. The use of hydrophilic interaction chromatography (HILIC) combined with reversed phase (RP) separations has already been demonstrated as a very orthogonal combination, which allows attaining increased resolving power. However, this coupling encompasses different analytical challenges, mainly related to the important solvent strength mismatch between the two dimensions, besides those common to every LC × LC method. In the present contribution, different strategies are proposed and compared to further increase HILIC × RP method performance for the analysis of complex food samples, using licorice as a model sample. The influence of different parameters in non-focusing modulation methods based on sampling loops, as well as under focusing modulation, through the use of trapping columns in the interface and through active modulation procedures are studied in order to produce resolving power and sensitivity gains. Although the use of a dilution strategy using sampling loops as well as the highest possible first dimension sampling rate allowed significant improvements on resolution, focusing modulation produced significant gains also in peak capacity and sensitivity. Overall, the obtained results demonstrate the great applicability and potential that active modulation may have for the analysis of complex food samples, such as licorice, by HILIC × RP. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Considerations in applying on-line IC techniques to BWR's

    International Nuclear Information System (INIS)

    Kaleda, R.J.

    1992-01-01

    Ion-Chromatography (IC) has moved from its traditional role as a laboratory analytical tool to a real time, dynamic, on-line measurement device to follow ppb and sub-ppb concentrations of deleterious impurities in nuclear power plants. Electric Power Research Institute (EPRI), individual utilities, and industry all have played significant roles in effecting the transition. This paper highlights considerations and the evolution in current on-line Ion Chromatography systems. The first applications of on-line techniques were demonstrated by General Electric (GE) under EPRI sponsorship at Rancho Seco (1980), Calvert Cliffs, and McGuire nuclear units. The primary use was for diagnostic purposes. Today the on-line IC applications have been expanded to include process control and routine plant monitoring. Current on-line IC's are innovative in design, promote operational simplicity, are modular for simplified maintenance and repair, and use field-proven components which enhance reliability. Conductivity detection with electronic or chemical suppression and spectrometric detection techniques are intermixed in applications. Remote multi-point sample systems have addressed memory effects. Early applications measured ionic species in the part per billion range. Today reliable part per trillion measurements are common for on-line systems. Current systems are meeting the challenge of EPRI guideline requirements. Today's on-line IC's, with programmed sampling systems, monitor fluid streams throughout a power plant, supplying data that can be trended, stored and retrieved easily. The on-line IC has come of age. Many technical challenges were overcome to achieve today's IC

  12. Automated sequential injection-microcolumn approach with on-line flame atomic absorption spectrometric detection for implementing metal fractionation schemes of homogeneous and non-homogeneous solid samples of environmental interest

    DEFF Research Database (Denmark)

    Chomchoei, Roongrat; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    spectrometric detection and used for the determination of Cu as a model analyte, the potentials of this novel hyphenated approach are demonstrated by the ability of handling up to 300 mg sample of a nonhomogeneous sewage amended soil (viz., CRM 483). The three steps of the endorsed Standards, Measurements...

  13. Hyphenating multisyringe flow injection lab-on-valve analysis with atomic fluorescence spectrometry for on-line bead-injection preconcentration and determination of trace levels of hydride-forming elements in environmental samples

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    the determination of ultratrace level concentrations of total inorganic arsenic in freshwater. Employing quantitative preoxidation of As(III) to As(V) in the samples by means of permanganate, the method involves the preconcentration of arsenate at pH 10 on a renewable anion exchanger, namely Q-Sepharose, packed...

  14. Tandem on-line continuous separations for atomic spectroscopic indirect analysis: iodide determination by ICP-AES

    International Nuclear Information System (INIS)

    Garcia, A.M.; Sanchez Uria, J.E.; Sanz-Medel, A.; Quintero Ortega, M.C.; Bautista, J.C.

    1992-01-01

    A sensitive and selective indirect determination of iodide by inductively coupled plasma emission spectrometry (ICP-AES) based on the principle of tandem on-line continuous separations as an alternative means of introducing samples into plasmas is proposed. Iodide is continuously extracted as an ion-pair into xylene by mixing the sample with Hg(II) and dipyridil solutions. The organic phase (containing the analyte in [Hg(Dipy) 2 ]I 2 form) is on-line continuously mixed with NaBH 4 (in DMF) and acetic acid solutions. Mercury vapour continuously generated from this organic phase is separated in a classical U-type gas-liquid separation device. The system has been optimized for the continuous extraction of KI, for the direct generation of cold mercury vapour from xylene and for the final ICP-AES determination of mercury. The optimised method has been applied to the determination of iodide (detection limit 20 ng/ml of iodide) in table salt and in synthetic samples. Very good agreement between found and certified results was observed. The usefulness and convenience of such alternative sample chemical pretreatment/presentation to the ICP is thus demonstrated for indirect determinations to be carried out by atomic spectroscopy methods. (authors)

  15. Approaches for on-line coupling of extraction and chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland)

    2004-04-01

    This review provides an overview of the approaches available in order to perform on-line coupling of various extraction techniques with liquid and gas chromatography, for the analysis of semivolatile and nonvolatile analytes in liquid and solid samples. The main focus is on the instrumental set-up of these techniques. Selected real applications are described by way of illustration. The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid extraction, solid-phase extraction, membrane-based techniques, pressurised liquid extraction, supercritical fluid extraction, and microwave- and sonication-assisted extractions. The following systems are not covered in this review: on-line coupled solid-phase extraction-liquid chromatography, purge-and-trap-GC, and membrane extraction with a sorbent interface-GC. (orig.)

  16. On line photochemically induced excitation-emission-kinetic four-way data

    International Nuclear Information System (INIS)

    Jimenez Giron, A.; Duran-Meras, I.; Espinosa-Mansilla, A.; Munoz de la Pena, A.; Canada Canada, F.; Olivieri, A.C.

    2008-01-01

    The determination of folic acid and its two main serum metabolites, 5-methyltetrahydrofolic acid and tetrahydrofolic acid, has been accomplished using four-way data modelled by the third-order multivariate calibration methods unfolded and N-dimensional partial least-squares (U-PLS and N-PLS), in combination with the separate procedure known as residual trilinearization (RTL). The four-way data were acquired by following the photochemical reaction of these compounds by on line irradiation with a UV lamp. The excitation-emission matrices (EEMs) were recorded as a function of the irradiation time, using a fast scanning spectrofluorimeter. The method achieves selectivity from the different rates at which the corresponding photoproducts of the folic acid derivatives are formed and degraded. Several N-dimensional chemometric algorithms were used and the method was applied to the determination of these compounds in serum samples. The best algorithms to perform the multivariate calibration were U-PLS and N-PLS in combination with the separate residual trilinearization procedure, achieving the second-order advantage. The approach allows minimizing or eliminating traditionally time-consuming sample pre-treatments and can facilitate quantifying an analyte in its native environment

  17. Shawnee Mission's On-Line Cataloging System

    Directory of Open Access Journals (Sweden)

    Ellen Wasby Miller

    1971-03-01

    Full Text Available An on-line cataloging pilot project for two elementary schools is discussed. The system components are 2740 terminals, upper-lower-case input, IBM's FASTER generalized software package, and usual cards/labels output. Reasons for choosing FASTER, software and hardware features, operating procedures, system performance and costs are detailed. Future expansion to cataloging 100,000 annual K-12 acquisitions, on-line circulation, retrospective conversion, and union book catalogs is set forth.

  18. INIS retrieval service, towards on-line

    International Nuclear Information System (INIS)

    Ebinuma, Yukio; Komatsubara, Yasutoshi

    1983-01-01

    Japan Atomic Energy Research Institute executes the retrieval service of INIS atomic energy information by batch system in cooperation with Genshiryoku Kozaikai. This service is very popular to the users in whole Japan, but the demand of on-line service has increased recently. Therefore, it was decided to begin the INIS on-line service from January, 1984, through the on-line information retrieval system of the Japan Information Center of Science and Technology. It is expected that when the operation will be started, the utilization of INIS atomic energy information in Japan will drastically increase. Also Japan Atomic Energy Research Institute has carried out the retrieval service by on-line system for those in the institute besides the batch system, accordingly, at this opportunity, the state of utilization of both systems and their distinction to use effectively, and the operation and the method of utilization of the on-line information retrieval system of JICST are explained. In the on-line system, the users are accessible to the data base themselves, and immediate information retrieval is possible, while in the batch system, the related information can be retrieved without fail, and the troublesome operation of equipment is not necessary. (Kako, I.)

  19. Semi-on-line analysis for fast and precise monitoring of bioreaction processes

    DEFF Research Database (Denmark)

    Christensen, L.H.; Marcher, J.; Schulze, Ulrik

    1996-01-01

    Monitoring of substrates and products during fermentation processes can be achieved either by on-line, in situ sensors or by semi-on-line analysis consisting of an automatic sampling step followed by an ex situ analysis of the retrieved sample. The potential risk of introducing time delays...

  20. On-line analysis of water contamination by organic compounds; On-line-Analytik der Wasserverschmutzung durch organische Substanzen

    Energy Technology Data Exchange (ETDEWEB)

    Wagt, R. van der; Vos, F. de [Skalar Analytical (Netherlands); Babichenko, S.; Poryvkina, L. [Institute of Ecology, Tallinn (Estonia)

    1999-08-01

    In many environmental applications decomposing the mixture of substances in the water into its various chemical ingredients, for subsequent analysis, is a very complicated task. The most productive approach to on-line diagnosis is to treat the object as an integral spectroscopic sample, characterized by certain specific Spectral Fluorescent Signatures (SFS). The SFS are recorded as a matrix of fluorescent intensity of organic compounds in water, in co-ordinates of excitation and emission spectra, providing a three-dimensional spectrum. Spectral windows of SFS are defined by fluorescent characteristics of basic groups of organic substances in the water sample. The novel Skalar Fluo Imager, based on this principle, is intended for the analysis of organic compounds in natural, domestic, and technological waters in an on-line mode. (orig.) [German] In vielen Umweltschutzanwendungen stellt die Auftrennung eines Substanzgemisches zum Zweck der Analyse eine sehr komplizierte Aufgabe dar. Ein erfolgversprechender Ansatz fuer eine on-line-Diagnostik besteht darin, das Objekt als integrale Spektroskopieprobe zu betrachten, die durch bestimmte spezifische Spektral-Fluoreszenz-Signaturen (SFS) charakterisiert wird. Diese werden als Fluoreszenz-Intensitaets-Matrix organischer Verbindungen in Wasser dargestellt, mit Anregungs- und Emissionsspektren als weiteren Koordinaten, wodurch ein dreidimensionales Spektrum entsteht. Spektrale Fenster der SFS sind definiert als Fluoreszenzcharakteristika von Funktionsgruppen organischer Substanzen in der Wasserprobe. Der auf diesem Prinzip basierende Skalar Fluo Imager ist fuer die on-line-Analyse organischer Bestandteile in natuerlichen, Haus- und technischen Waessern gedacht. (orig.)

  1. Sample pretreatment optimization for the analysis of short chain chlorinated paraffins in soil with gas chromatography-electron capture negative ion-mass spectrometry.

    Science.gov (United States)

    Chen, Laiguo; Huang, Yumei; Han, Shuang; Feng, Yongbin; Jiang, Guo; Tang, Caiming; Ye, Zhixiang; Zhan, Wei; Liu, Ming; Zhang, Sukun

    2013-01-25

    Accurately quantifying short chain chlorinated paraffins (SCCPs) in soil samples with gas chromatograph coupled with electron capture negative ionization mass spectrometry (GC-ECNI-MS) is difficult because many other polychlorinated pollutants are present in the sample matrices. These pollutants (e.g., polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and toxaphene) can cause serious interferences during SCCPs analysis with GC-MS. Four main columns packed with different adsorbents, including silica gel, Florisil and alumina, were investigated in this study to determine their performance for separating interfering pollutants from SCCPs. These experimental results suggest that the optimum cleanup procedure uses a silica gel column and a multilayer silica gel-Florisil composite column. This procedure completely separated 22 PCB congeners, 23 OCPs and three toxaphene congeners from SCCPs. However, p,p'-DDD, cis-nonachlor and o,p'-DDD were not completely removed and only 53% of the total toxaphene was removed. This optimized method was successfully and effectively applied for removing interfering pollutants from real soil samples. SCCPs in 17 soil samples from different land use areas within a suburban region were analyzed with the established method. The concentrations of SCCPs in these samples were between 7 and 541 ng g(-1) (mean: 84 ng g(-1)). Similar homologue SCCPs patterns were observed between the soil samples collected from different land use areas. In addition, lower chlorinated (Cl(6/7)) C(10)- and C(11)- SCCPs were the dominant congeners. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography.

    Science.gov (United States)

    Lhotská, Ivona; Holznerová, Anežka; Solich, Petr; Šatínský, Dalibor

    2017-12-01

    Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, M.

    2005-09-01

    On-Line Monitoring evaluates instrument channel performance by assessing its consistency with other plant indications. Elimination or reduction of unnecessary field calibrations can reduce associated labour costs, reduce personnel radiation exposure, and reduce the potential for calibration errors. On-line calibration monitoring is an important technique to implement a state-based maintenance approach and reduce unnecessary field calibrations. In this report we will look at how the concept is currently applied in the industry and what the arising needs are as it becomes more commonplace. We will also look at the PEANO System, a tool developed by the Halden Project to perform signal validation and on-line calibration monitoring. Some issues will be identified that are being addressed in the further development of these tools to better serve the future needs of the industry in this area. An outline for how to improve these points and which aspects should be taken into account is described in detail. (Author)

  4. On-line signal trend identification

    International Nuclear Information System (INIS)

    Tambouratzis, T.; Antonopoulos-Domis, M.

    2004-01-01

    An artificial neural network, based on the self-organizing map, is proposed for on-line signal trend identification. Trends are categorized at each incoming signal as steady-state, increasing and decreasing, while they are further classified according to characteristics such signal shape and rate of change. Tests with model-generated signals illustrate the ability of the self-organizing map to accurately and reliably perform on-line trend identification in terms of both detection and classification. The proposed methodology has been found robust to the presence of white noise

  5. On line routing per mobile phone

    DEFF Research Database (Denmark)

    Bieding, Thomas; Görtz, Simon; Klose, Andreas

    2009-01-01

    On-line routing is concerned with building vehicle routes in an ongoing fashion in such a way that customer requests arriving dynamically in time are efficiently and effectively served. An indispensable prerequisite for applying on-line routing methods is mobile communication technology....... Additionally it is of utmost importance that the employed communication system is suitable integrated with the firm’s enterprise application system and business processes. On basis of a case study, we describe in this paper a system that is cheap and easy to implement due to the use of simple mobile phones...

  6. On-line atomic data access

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, D.R. [Oak Ridge National Lab., TN (United States); Nash, J.K. [Lawrence Livermore National Lab., CA (United States)

    1996-04-01

    The need for atomic data is one which continues to expand in a wide variety of applications including fusion energy, astrophysics, laser- produced plasma research, and plasma processing. Modern computer database and communications technology nables this data to be placed on-line and obtained by users of the Internet. Presented here is a summary of the observations and conclusions regarding such on-line atomic data access derived from a forum held at the Tenth APS Topical Conference on Atomic Processes in Plasmas.

  7. Methods for pretreating biomass

    Science.gov (United States)

    Balan, Venkatesh; Dale, Bruce E; Chundawat, Shishir; Sousa, Leonardo

    2017-05-09

    A method for pretreating biomass is provided, which includes, in a reactor, allowing gaseous ammonia to condense on the biomass and react with water present in the biomass to produce pretreated biomass, wherein reactivity of polysaccharides in the biomass is increased during subsequent biological conversion as compared to the reactivity of polysaccharides in biomass which has not been pretreated. A method for pretreating biomass with a liquid ammonia and recovering the liquid ammonia is also provided. Related systems which include a biochemical or biofuel production facility are also disclosed.

  8. On-line chemistry monitoring for the secondary side

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Babcock and Wilcox (B and W) has developed a computerized water chemistry data acquisition and management system for nuclear plant secondary coolant systems. The Integrated Water Chemistry Monitoring System (IWCMS) provides on-line monitoring of conditions and rapid trend analysis of sampled data. So far it has been installed at GPU Three Mile Island unit 1 and at Toledo Edison Davis-Besse. The IWCMS meets the following utility needs for monitoring power plant chemistry: control of chemistry conditions to minimize corrosion and extend component/system life; continuous analysis of data from on-line detectors and grab samples; expediting of transient recovery actions with trend, alarm and evaluation capability; provision for rapid sharing of useful operational chemistry information; concentration of attention on evaluation instead of data manipulation. The system is composed of three functional parts: data acquisition hardware; PC-based computer system and customised system software. (author)

  9. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2008-01-01

    Full Text Available The on-line user of today has access to a vast collection of information resources. In addition, the developments in Internet and Web technologies have made it even easier for surfers to anonymously get access to on-line pornography. The purpose of this research was to investigate the extent to which access to on-line pornography at the University of Johannesburg can be managed. For the empirical part of this research 1037 questionnaires were proportionally distributed to and completed by students on all five campuses of the university. The questionnaire consisted of four sections: biographical information; university computer facility usage; university acceptable use policy; and personal experience with university computer facilities. The gender distribution for the sample was almost even, with a total of 49,4% male participants and 50,6% female, with the largest grouping of respondents (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  10. EFFECT OF AQUEOUS PRETREATMENT ON PYROLYSIS CHARACTERISTICS OF NAPIER GRASS

    Directory of Open Access Journals (Sweden)

    ISAH YAKUB MOHAMMED

    2015-11-01

    Full Text Available Effect of non-catalytic aqueous pretretment on pyrolysis characteristics of Napier grass was investigated using thermogravimetric analyser. Increasing pretreatment severity (0.0-2.0 improved pyrolysis process. The residual mass at the end of pyrolysis for the pretreated sample was about 50% less compared to the untreated sample. Kinetics of the process was evaluated using order based model and both pretreated and untreated samples followed first order reaction. The activation energy of the pretreated samples was similar and higher than that of the raw sample which was attributed to faster rate of decomposition due removal of hetromaterials (ash, extractives and some hemicellulose in the pretreatment stage. Finally, this pretreatment method has demonstrated effectiveness for the removal of pyrolysis retardants and will improve the quantity and quality of bio-oil yield.

  11. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, Mario; Gran, Frauke Schmitt; Thunem, Harald P-J.

    2004-04-01

    On-Line Monitoring (OLM) of a channel's calibration state evaluates instrument channel performance by assessing its consistency with other plant indications. Industry and experience at several plants has shown this overall approach to be very effective in identifying instrument channels that are exhibiting degrading or inconsistent performance characteristics. The Halden Reactor Project has developed the signal validation system PEANO, which can be used to assist with the tasks of OLM. To further enhance the PEANO System for use as a calibration reduction tool, the following two additional modules have been developed; HRP Prox, which performs pre-processing and statistical analysis of signal data, Batch Monitoring Module (BMM), which is an off-line batch monitoring and reporting suite. The purpose and functionality of the HRP Prox and BMM modules are discussed in this report, as well as the improvements made to the PEANO Server to support these new modules. The Halden Reactor Project has established a Halden On-Line Monitoring User Group (HOLMUG), devoted to the discussion and implementation of on-line monitoring techniques in power plants. It is formed by utilities, vendors, regulatory bodies and research institutes that meet regularly to discuss implementation aspects of on-line monitoring, technical specification changes, cost-benefit analysis and regulatory issues. (Author)

  12. SPIRES I: on-line search guide

    International Nuclear Information System (INIS)

    Addis, L.

    1975-06-01

    SPIRES I is the first generation of the on-line Stanford Public Information Retrieval System. Designed as a prototype system, SPIRES I was later moved to the SLAC computing facility where it has been routinely available to SLAC users in the field of high-energy physics. The scope and use of the SPIRES I system are described in this manual

  13. HOPI: on-line injection optimization program

    International Nuclear Information System (INIS)

    LeMaire, J.L.

    1977-01-01

    A method of matching the beam from the 200 MeV linac to the AGS without the necessity of making emittance measurements is presented. An on-line computer program written on the PDP10 computer performs the matching by modifying independently the horizontal and vertical emittance. Experimental results show success with this method, which can be applied to any matching section

  14. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  15. Comparison of the suitability of alkaline or enzymatic sample pre-treatment for characterization of silver nanoparticles in human tissue by single particle ICP-MS

    DEFF Research Database (Denmark)

    Vidmar, Janja; Buerki-Thurnherr, Tina; Löschner, Katrin

    2018-01-01

    and their size are required for studying NP accumulation in placental tissue. In the present study, we applied and compared two sample preparation techniques, alkaline and enzymatic treatment, followed by single particle ICP-MS (spICP-MS) analysis, for characterizing AgNPs spiked to human placental tissue. Both...... sample preparation approaches are currently used for AgNPs in biological tissues but have not been directly compared yet. We showed that the method using enzymatic tissue treatment followed by spICP-MS is efficient for determination of mass and number concentration and size distribution of AgNPs in human...... placental tissues. Properties of the AgNPs were preserved during enzymatic digestion and comparable with the primary particles. The matrix effect on the determination of Ag sensitivity and transport efficiency in spICP-MS analysis was systematically evaluated as well. The method was applied to human...

  16. The development of an on-line gold analyser

    International Nuclear Information System (INIS)

    Robert, R.V.D.; Ormrod, G.T.W.

    1982-01-01

    An on-line analyser to monitor the gold in solutions from the carbon-in-pulp process is described. The automatic system is based on the delivery of filtered samples of the solutions to a distribution valve for measurement by flameless atomic-absorption spectrophotometry. The samples is introduced by the aerosol-deposition method. Operation of the analyser on a pilot plant and on a full-scale carbon-in-pulp plant has shown that the system is economically feasible and capable of providing a continuous indication of the efficiency of the extraction process

  17. Educational On-Line Gaming Propensity

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana; Kirchner, Kathrin

    2014-01-01

    Educational on-line games are promising for new generations of students who are grown up digital. Th e new generations of students are technology savvy and spend lots of time on the web and on social networks. Based on an exploratory study, this article investigates the factors that infl uence...... students’ willingness to participate in serious games for teaching/learning. Th is study investigates the relationship between students’ behavior on Facebook, Facebook games, and their attitude toward educational on-line games. Th e results of the study reveal that the early adopters of educational games...... are likely to be students, who are young, have only a few Facebook connections, who currently play Facebook game(s). Furthermore, the study emphasizes that there may be differences between students coming from various countries....

  18. Trends in on-line data processing

    International Nuclear Information System (INIS)

    Masetti, M.

    1981-01-01

    The developement of integrated circuits has been characterized by an exponential growth of gates on a single chip that will still continue in the coming years. In parallel the price per bit is dropping down with more or less the same law. As a consequence of this a few statements can be made: The present 16-bit minicomputer in a small configuration is going to be substituted by a 16-bit microcomputer, and the 16-bit microcomputer in a powerful configuration by a 32-bit midi having also a virtual memory facility. Fully programmable or microcoded powerful devices like the LASS hardware processor or MICE, will allow an efficient on-line filter. Higher computing speed can be achieved by a multiprocessor configuration which can be insensitive to hardware failures. Therefore we are moving towards an integrated on-line computing system with much higher computing power than now and the present distinction between on-line and off-line will no longer be so sharp. As more processing can be performed on-line, fast high quality feed-back can be provided for the experiment. In the years to come the trend towards more processing power, at a lower price, and assembled in the same hardware volume will continue for at least five years; at the same time the future large high-energy physics experiments at LEP will be carried out within a wide international collaboration. In this environment methods must be found for a large fraction of the work to be distributed amongst the collaborators. To accomplish this aim it is necessary to introduce common standard practices concerning both hardware and software, in such a way that the seperate parts, developed by the collaborators, will be plug-compatible. (orig.)

  19. New Trends in on-line Marketing

    OpenAIRE

    Palkovič, Lukáš

    2011-01-01

    This bachelor thesis deals with new trend of internet marketing, it focuses especially on viral marketing. The theoretical part charasterizes the process of viral campaigns, furthermore deals with the components and aspects of on-line environment. Another separated chapter presents social networks, their place in viral marketing and at last but not least the viral video making process. The practical part contains different analyses of specific viral campaigns. The next and equally the last pa...

  20. On-Line Maintenance Methodology Development

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Won; Kim, Jae Ho; Jae, Moo Sung [Hanyang University, Seoul (Korea, Republic of)

    2012-05-15

    Most of domestic maintenance activities for nuclear power plants are performed while overhaul. Therefore, On-Line Maintenance (OLM) is one of the proper risks informed application techniques for diffusing maintenance burden during overhaul with safety of the plant is secured. The NUMARC 93-01 (Rev.3) presents the OLM state of the art and it provides methodology. This study adopts NUMARC 93-01 (Rev.3) and present OLM. The reference component is Emergency Diesel Generator (EDG) of Ulchin 3, 4

  1. Determination of chlorophenols in honey samples using in-situ ionic liquid-dispersive liquid-liquid microextraction as a pretreatment method followed by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Chen; Li, Nai; Cao, Xueli

    2015-05-01

    In-situ ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) method was developed as a pretreatment method for the detection of six chlorophenols (CPs) in honey samples. The hydrophobic ionic liquid [C4MIM][NTf2], formed in-situ by the hydrophilic ionic liquid [C4MIM][BF4] and the ion exchange reagent LiNTf2 was used as the microextractant solvent of CPs from honey sample. Then the enriched analytes were back-extracted into 40 μL of 0.14 M NaOH solution and finally subjected to analysis by high-performance liquid chromatography. The method showed low limit of detection of CPs, 0.8-3.2 μg/L and high enrichment factor, 34-65 with the recoveries range from 91.60% to 114.33%. The method is simple, rapid, environmentally friendly and with high extraction efficiency. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Rapid pretreatment and determination of bisphenol A in water samples based on vortex-assisted liquid-liquid microextraction followed by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Yang, Xiao; Diao, Chun-Peng; Sun, Ai-Ling; Liu, Ren-Min

    2014-10-01

    A method for the rapid pretreatment and determination of bisphenol A in water samples based on vortex-assisted liquid-liquid microextraction followed by high-performance liquid chromatography with fluorescence detection was proposed in this paper. A simple apparatus consisting of a test tube and a cut-glass dropper was designed and applied to collect the floating extraction drop in liquid-liquid microextraction when low-density organic solvent was used as the extraction solvent. Solidification and melting steps that were tedious but necessary once the low-density organic solvent used as extraction solvent could be avoided by using this apparatus. Bisphenol A was selected as model pollutant and vortex-assisted liquid-liquid microextraction was employed to investigate the usefulness of the apparatus. High-performance liquid chromatography with fluorescence detection was selected as the analytical tool for the detection of bisphenol A. The linear dynamic range was from 0.10 to 100 μg/L for bisphenol A, with good squared regression coefficient (r(2) = 0.9990). The relative standard deviation (n = 7) was 4.7% and the limit of detection was 0.02 μg/L. The proposed method had been applied to the determination of bisphenol A in natural water samples and was shown to be economical, fast, and convenient. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. The effect of wastewater pretreatment on nanofiltration membrane performance

    Directory of Open Access Journals (Sweden)

    Ali Hashlamon

    2017-03-01

    Full Text Available Membrane fouling is considered a serious obstacle for operation and cost efficiency in wastewater treatment using nanofiltration (NF. However, pretreatment is the most practical way to reduce this prior to NF. In this research, two types of wastewaters were pretreated with different methods prior to NF to examine the effect of pretreatment on membrane fouling in terms of turbidity, chemical oxygen demand (COD and permeate flux. Turbidity and COD were measured to assess solid foulants and organic species in the wastewater, respectively. The first sample was secondary treated sewage, which was pretreated using coagulation-flocculation-sedimentation (CFS only. Steady flux was increased from 24 L/m2h for wastewater without pretreatment to 32.1 L/m2h with pretreatment. COD was also eliminated after CFS/NF, and turbidity was reduced to 0.6 NTU. The second sample was diluted biodiesel wastewater, which was pretreated using a combination of powdered-activated carbon (PAC adsorption and CFS (PAC/CFS. Steady flux was increased from 22.3 L/m2h for wastewater without pretreatment to 28.7 L/m2h with pretreatment; biodiesel wastewater quality also improved. Turbidity was reduced from 12 to 0.6 NTU, and COD was reduced from 526 to 4 mg/L after NF with PAC/CFS pretreatment, while COD was reduced from 526 to 95 mg/L using NF without pretreatment.

  4. Development of procedure for measurement of Pb isotope ratios in seawater by application of seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Vassileva, Emilia; Wysocka, Irena

    2016-12-01

    Anthropogenic Pb in the oceans, derived from high-temperature industrial processes, fuel combustion and incineration can have an isotopic signature distinct from naturally occurring Pb, supplied by rock weathering. To identify the different pollution sources accurately and to quantify their relative contributions, Pb isotope ratios are widely used. Due to the high salt content (approximately 3.5% of total dissolved solids) and very low levels of Pb (typically from 1 to 100 ng L- 1) in seawater the determination of Pb isotope ratios requires preliminary matrix separation and analyte preconcentration. An analytical protocol for the measurements of Pb isotope ratios in seawater combining seaFAST sample pre-treatment system and Sector Field Inductively Coupled Plasma Mass Spectrometry (SF ICP-MS) was developed. The application of seaFAST system was advantageous, because of its completely closed working cycle and small volumes of chemicals introduced in pre-treatment step, resulting in very low detection limits and procedural blanks. The preconcentration/matrix separation step was also of crucial importance for minimizing the isobaric and matrix interferences, coming from the seawater. In order to differentiate between anthropogenic and natural Pb sources, particular attention was paid to the determination of 204Pb isotope because of its implication in some geological interpretations. The validation of the analytical procedure was effectuated according to the recommendations of the ISO/IEC 17025 standard. The method was validated by processing the common Pb isotope reference material NIST SRM 981. All major sources of uncertainty were identified and propagated together following the ISO/GUM guidelines. The estimation of the total uncertainty associated to each measurement result was fundamental tool for sorting the main sources of possible biases. The developed analytical procedure was applied to the coastal and open seawater samples, collected in different regions of

  5. Impact of pretreatment on colour and texture of watermelon rind

    Science.gov (United States)

    Athmaselvi, K.; Alagusundaram, K.; Kavitha, C.; Arumuganathan, T.

    2012-07-01

    The effect of osmotic dehydration pretreatment on water loss, solid gain, colour and textural change was investigated. Watermelon rind 1 x 1 cm size was immersed in sucrose solution of 40, 50 and 60° Brix after pretreatment with microwave and conventional boiling in water for 1, 3, and 5 min, respectively. Water loss and solid gain increased with the time of cooking and sugar concentration. Microwave pretreated samples showed higher water loss and solid gain. Increase in the time of cooking decreased the brightness of all the samples. Microwave pretreated samples showed higher `b' values than conventionally pretreated ones. There was no significant difference (P≤0.05) in texture profile analysis parameters except for hardness. Hardness decreased with increase in time of cooking and sugar concentration. Second order regression model was developed for water loss and solid gain of microwave and conventional pretreated watermelon rind.

  6. Automated system for on-line determination of dimethylarsinic and inorganic arsenic by hydride generation-atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chaparro, L.L.; Leal, L.O. [Renewable Energy and Environmental Protection Department, Advanced Materials Research Center (CIMAV), Chihuahua, Chihuahua (Mexico); Ferrer, L.; Cerda, V. [University of the Balearic Islands, Department of Chemistry, Palma de Mallorca (Spain)

    2012-09-15

    A multisyringe flow-injection approach has been coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS) with UV photo-oxidation for dimethylarsinic (DMA), inorganic As and total As determination, depending on the pre-treatment given to the sample (extraction or digestion). The implementation of a UV lamp allows on-line photo-oxidation of DMA and the following arsenic detection, whereas a bypass leads the flow directly to the HG-AFS system, performing inorganic arsenic determination. DMA concentration is calculated by the difference of total inorganic arsenic and measurement of the photo-oxidation step. The detection limits for DMA and inorganic arsenic were 0.09 and 0.47 {mu}g L{sup -1}, respectively. The repeatability values accomplished were of 2.4 and 1.8 %, whereas the injection frequencies were 24 and 28 injections per hour for DMA and inorganic arsenic, respectively. This method was validated by means of a solid reference material BCR-627 (muscle of tuna) with good agreement with the certified values. Satisfactory results for DMA and inorganic arsenic determination were obtained in several water matrices. The proposed method offers several advantages, such as increasing the sampling frequency, low detection limits and decreasing reagents and sample consumption, which leads to lower waste generation. (orig.)

  7. On line nuclear orientation: opportunity and challenge

    International Nuclear Information System (INIS)

    Stone, N.J.

    1985-01-01

    The development of the on-line nuclear orientation (OLNO) technique is reviewed. The present potential of the technique is discussed in the light of the attainable temperatures, the use of ion implantation and the required isotope flux. Limitations associated with spin-lattice relaxation are considered in some detail and a survey of accessible nuclei is presented. An outline comparison is given between OLNO and other methods for producing orientation of nuclei, for measuring nuclear spins and static moments and for the study of level structure and transition probabilities. The conclusion is drawn that the method in its present form has extensive potential over a wide range of nuclei. Future prospects for in-beam polarisation giving access to nuclei of shorter half lives are referred to briefly. (Auth.)

  8. An on-line diagnostic expert system

    International Nuclear Information System (INIS)

    Felkel, L.

    1987-01-01

    As experience with on-line information systems, experts systems and artificial intelligence tools grows, the authors retreat from the first euphoria that AI could help them solve the problem they were unable to solve with conventional programming. The major effort of the development time goes into building the knowledge-base. There is no such thing as a generic knowledge-base for nuclear power plants as there is, for example, for the diagnosis of a Boeing 747 aircraft. AI-methods, tools and hardware are still in a state which does not optimally lend itself to real-time application. The ability of developing prototype systems to investigate variants otherwise too costly to justify is one advantage that the authors gladly accept. Last, but no least the tools provide a flexible and adaptable user interface (desktop window systems) etc. The development of such tools in a project would be prohibitive and room for experimentation would be limited

  9. On-Line Algorithms and Reverse Mathematics

    Science.gov (United States)

    Harris, Seth

    In this thesis, we classify the reverse-mathematical strength of sequential problems. If we are given a problem P of the form ∀X(alpha(X) → ∃Zbeta(X,Z)) then the corresponding sequential problem, SeqP, asserts the existence of infinitely many solutions to P: ∀X(∀nalpha(Xn) → ∃Z∀nbeta(X n,Zn)). P is typically provable in RCA0 if all objects involved are finite. SeqP, however, is only guaranteed to be provable in ACA0. In this thesis we exactly characterize which sequential problems are equivalent to RCA0, WKL0, or ACA0.. We say that a problem P is solvable by an on-line algorithm if P can be solved according to a two-player game, played by Alice and Bob, in which Bob has a winning strategy. Bob wins the game if Alice's sequence of plays 〈a0, ..., ak〉 and Bob's sequence of responses 〈 b0, ..., bk〉 constitute a solution to P. Formally, an on-line algorithm A is a function that inputs an admissible sequence of plays 〈a 0, b0, ..., aj〉 and outputs a new play bj for Bob. (This differs from the typical definition of "algorithm", though quite often a concrete set of instructions can be easily deduced from A.). We show that SeqP is provable in RCA0 precisely when P is solvable by an on-line algorithm. Schmerl proved this result specifically for the graph coloring problem; we generalize Schmerl's result to any problem that is on-line solvable. To prove our separation, we introduce a principle called Predictk(r) that is equivalent to -WKL0 for standard k, r.. We show that WKL0 is sufficient to prove SeqP precisely when P has a solvable closed kernel. This means that a solution exists, and each initial segment of this solution is a solution to the corresponding initial segment of the problem. (Certain bounding conditions are necessary as well.) If no such solution exists, then SeqP is equivalent to ACA0 over RCA 0 + ISigma02; RCA0 alone suffices if only sequences of standard length are considered. We use different techniques from Schmerl to prove

  10. Software for on-line experiments

    International Nuclear Information System (INIS)

    Ivanchenko, I.M.

    1981-01-01

    A review of nowadays development state of software of on-line electron experiments is presented. The principles of organization of real time systems on second generation computer base are considered. The following methods for projections search are considered: combinator methods, global methods, methods of tracking, methods of a supporting band. The following methods for determining parameter estimates based on the Lorentz equation are analysed: analytical simulation of trajectories, determination of parameters by the iterative method using the technique of calculation of recycled integrals, multidimensional statistical analysis. For the purpose of successful usage and development of software the technique of selfdocumented programs is created and the computer is applied for preparing, revising and circulation of external descriptions which as program complexes are constructed according to the hierarchical principle [ru

  11. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  12. Aprender a innovar: una experiencia on line

    Directory of Open Access Journals (Sweden)

    Joaquín MORENO MARCHAL

    2014-11-01

    Full Text Available La creatividad y la innovación se han convertido en recursos clave en la denominada sociedad del conocimiento, que bien podría ser también llamada sociedad de la innovación. Pero innovar es una actividad compleja, que integra la aplicación de múltiples capacidades, el pensamiento divergente y convergente, la gestión de equipos humanos, la comunicación. Ahora bien, a innovar se puede, y se debe, aprender. Aprender a innovar es un reto y también una obligación para el conjunto del sistema educativo en todos sus niveles. Partiendo de estas consideraciones este trabajo expone una experiencia de aprendizaje de la creatividad y de la innovación a través de un curso totalmente on line basado en la plataforma MOODLE, en el marco del Programa de Formación Permanente de la Universidad de Cádiz. Se presenta un modelo del proceso de innovación, denominado CREALAB, de elaboración propia. Este modelo se ha utilizado como base del proceso de aprendizaje de la creatividad y de la innovación y en el diseño del curso, está organizado en torno a actividades y tiene un carácter iterativo y realimentado. Se presentan además el conjunto del diseño metodológico y los resultados obtenidos en las dos ediciones celebradas hasta el momento. El diseño del curso totalmente on line y los resultados alcanzados permiten estimar un alto potencial de aplicación, tanto a nivel personal como a nivel organizacional.

  13. The Effect of Ultrasound Pretreatment on Poplar Wood Dimensional Stability

    Directory of Open Access Journals (Sweden)

    Shu Qiu

    2016-08-01

    Full Text Available Dimensional stability is a key property of wood that significantly affects its applications. The effect of an ultrasound pretreatment on poplar wood (Populous tomentosa dimensional stability was examined. During the pretreatments, wood samples were immersed in distilled water and treated ultrasonically under three different powers and frequencies. The samples were then analyzed by Fourier transform infrared spectroscopy (FTIR and X-ray diffraction (XRD. The chemical transformation of the cell-wall material was studied and then associated with the change of water absorption and the swelling coefficient. The results showed that the water absorption decreased after the ultrasonic pretreatment. The axial and radial swelling coefficients of the pretreated samples decreased, while the tangential swelling coefficients increased. The volumetric swelling coefficient of pretreated specimens fluctuated near 4.48% (the volumetric swelling coefficient of untreated wood. Ultrasonic pretreatment increased the number of hydrophilic groups, such as the hydroxyl, acetyl, and uronic ester groups. Meanwhile, the pretreatment also increased the degree of crystallinity and reduced the available polar groups. These two factors together caused the change of the moisture absorption and the swelling coefficient of the pretreated wood. These conclusions suggest that the ultrasonic pretreatment is a promising method for further chemical modification of wood.

  14. GREET Pretreatment Module

    Energy Technology Data Exchange (ETDEWEB)

    Adom, Felix K. [Argonne National Lab. (ANL), Argonne, IL (United States). Energy Systems Division; Dunn, Jennifer B. [Argonne National Lab. (ANL), Argonne, IL (United States). Energy Systems Division; Han, Jeongwoo [Argonne National Lab. (ANL), Argonne, IL (United States). Energy Systems Division

    2014-09-01

    A wide range of biofuels and biochemicals can be produced from cellulosic biomass via different pretreatment technologies that yield sugars. Process simulations of dilute acid and ammonia fiber expansion pretreatment processes and subsequent hydrolysis were developed in Aspen Plus for four lignocellulosic feedstocks (corn stover, miscanthus, switchgrass, and poplar). This processing yields sugars that can be subsequently converted to biofuels or biochemical. Material and energy consumption data from Aspen Plus were then compiled in a new Greenhouses Gases, Regulated Emissions, and Energy Use in Transportation (GREETTM) pretreatment module. The module estimates the cradle-to-gate fossil energy consumption (FEC) and greenhouse gas (GHG) emissions associated with producing fermentable sugars. This report documents the data and methodology used to develop this module and the cradle-to-gate FEC and GHG emissions that result from producing fermentable sugars.

  15. Human interface for personal information systems. On-line handwriting recognition; Pasonaru joho kiki ni okeru human interface. On-line tegaki ninshiki

    Energy Technology Data Exchange (ETDEWEB)

    Morita, T. [Sharp Corp., Osaka (Japan)

    1996-01-05

    Most of information devices used in the business field use keyboards for the inputting measure, but keyboards are rather awkward for personal use. In contrast to this, the pen input method which everybody can use easily is a product of the latest development. In this articles, on-line handwritten letter recognition is roughly explained which is the basic technique of pen input. Pen input has a demerit that its letter inputting speed is slow, but has much more merits that Chinese ideographs can be directly input, figures, handwritten memoranda, etc. are treated likewise, the device itself can be made compact and no noise is made. The on-line letter recognition methods now used practically can be roughly divided into the pattern matching method and the basic stroke method. Each of them has its own merits and demerits. For the current on-line handwritten letter recognition, the condition is necessary to handwritten a letter in the square style (kaisho) and carefully within the framework for letter entry upon writing, and for this arrangement, input is performed through the work processes of pretreatment/feature extraction, stroke recognition, letter comparison, detail discrimination, and after-treatment. 3 refs., 7 figs.

  16. PRETREATING THORIUM FOR ELECTROPLATING

    Science.gov (United States)

    Beach, J.G.; Schaer, G.R.

    1959-07-28

    A method is presented for pretreating a thorium surface prior to electroplating the surface. The pretreatment steps of the invention comprise cleaning by vapor blasting the surface, anodically pickling in a 5 to 15% by volume aqueous hydrochloric acid bath with a current of 125 to 250 amp/sq ft for 3 to 5 min at room temperature, chemically pickling the surface in a 5 to 15% by volume of aqueous sulfuric acid for 3 to 5 min at room temperature, and rinsing the surface with water.

  17. Biochemical degradation and physical migration of polyphenolic compounds in osmotic dehydrated blueberries with pulsed electric field and thermal pretreatments.

    Science.gov (United States)

    Yu, Yuanshan; Jin, Tony Z; Fan, Xuetong; Wu, Jijun

    2018-01-15

    Fresh blueberries were pretreated by pulsed electric fields (PEF) or thermal pretreatment and then were subject to osmotic dehydration. The changes in contents of anthocyanins, predominantly phenolic acids and flavonols, total phenolics, polyphenol oxidase (PPO) activity and antioxidant activity in the blueberry samples during pretreatment and osmotic dehydration were investigated. Biochemical degradation and physical migration of these nutritive compounds from fruits to osmotic solutions were observed during the pretreatments and osmotic dehydration. PEF pretreated samples had the least degradation loss but the most migration loss of these compounds compared to thermally pretreated and control samples. Higher rates of water loss and solid gain during osmotic dehydration were also obtained by PEF pretreatment, reducing the dehydration time from 130 to 48h. PEF pretreated and dehydrated fruits showed superior appearance to thermally pretreated and control samples. Therefore, PEF pretreatment is a preferred technology that balances nutritive quality, appearance, and dehydration rate. Published by Elsevier Ltd.

  18. NOASYS, a system for on-line noise analysis

    International Nuclear Information System (INIS)

    Massier, H.

    1978-07-01

    This report describes NOASYS, a versatile NOise Analysis SYStem for digital on-line signal processing. The system based on a minicomputer, was originally developed for the analysis of noise signals from nuclear reactors. NOASYS computes various statistical functions e.g. cross- und auto-correlation functions and power spectral densities resp., which may be used for reactor diagnosis and malfunction detection. The system processes up to 16 analog signals with a maximum sampling frequency of 100 kcps (1 channel). The processing of the sampled data is done by a number of software tasks, which may be called from a teletype or linked together for specific measuring programs. The standard configuration contains the often used processing routines e.g. Fast Fourier Transform, complex multiplication, summation etc. In addition NOASYS may be extended by users own tasks (in Assembler or Fortran) to fit for specific applications. (orig.) 891 HP [de

  19. Influence of ultrasound pretreatment on wood physiochemical structure.

    Science.gov (United States)

    He, Zhengbin; Wang, Zhenyu; Zhao, Zijian; Yi, Songlin; Mu, Jun; Wang, Xiaoxu

    2017-01-01

    As an initial step to increase the use of renewable biomass resources, this study was aimed at investigating the effects of ultrasound pretreatment on structural changes of wood. Samples were pretreated by ultrasound with the power of 300W and frequency of 28kHz in aqueous soda solution, aqueous acetic acid, or distilled water, then pretreated and control samples were characterized via X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA). The results shown that ultrasound pretreatment is indeed effective in modifying the physiochemical structure of eucalyptus wood; the pretreatment decreased the quantity of alkali metals (e.g., potassium, calcium and magnesium) in the resulting material. Compared to the control group, the residual char content of samples pretreated in aqueous soda solution increased by 10.08%-20.12% and the reaction temperature decreased from 361°C to 341°C, however, in samples pretreated by ultrasound in acetic solution or distilled water, the residual char content decreased by 12.40%-21.45% and there were no significant differences in reactivity apart from a slightly higher maximum reaction rate. Ultrasound pretreatment increased the samples' crystallinity up to 35.5% and successfully removed cellulose, hemicellulose, and lignin from the samples; the pretreatment also increased the exposure of the sample to the treatment solutions, broke down sample pits, and generated collapses and microchannels on sample pits, and removed attachments in the samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. On-line maintenance at Cofrentes NPP

    International Nuclear Information System (INIS)

    Roldan Vilches, J.; Moreno Matarranz, M. A.; Hermana Mendioroz, I.

    1998-01-01

    Cofrentes NPP has begun in 1997 activities related to At Power Preventive Maintenance over trains or systems which lead to a voluntary entry in a Limitative Condition of Operation (LCO) of the Technical Specifications. From others benefits, this program ha improved the risk management and the staff's knowledge over the functions and safety implications of the different systems, the better exploit of the resources, the co-ordination of the different organisations involved (Maintenance an Operation) and the reductions of works during shutdowns. Previous to each work, a feasibility study analyzes qualitative and quantitative (PSA), using the Risk Monitor, the implications on safety of all the tasks, assuring that the global safety of the Plant is always maintained. Tech. Spec. are analyzed in detail and also are analyzed situations of simultaneous unavailabilities of systems which could lead to a high risk situation. Two different risk controls are defined (punctual and accumulated) to assure that high risk situations will not be given. Finally, historical risk profile is analyzed to assure that the accumulated risk increase is not significant. Risk Monitor helps staff in the schedule and follow-up of the activities of On-Line Maintenance. Each one of the tasks are deeply planned and harshly analyzed and are carried out by high qualified workers. By the moment, this program is running with fully satisfaction on the Plant. (Author)

  1. SOL: INNOVACIÓN ON-LINE

    Directory of Open Access Journals (Sweden)

    Rubén Faúndez

    2007-11-01

    Full Text Available Las aplicaciones de simulación tienden a ser cada vez más cercanas a usuarios e industrias. Sin embargo, muchas de ellas no poseen ni la capacidad ni el conocimiento como para desarrollar internamente sus modelos de simulación. Por este motivo, y como una forma de apoyar la toma de decisiones basándose en modelos de simulación, se presenta la plataforma SOL (Simulación On Line. La metodología completa de trabajo, así como la interacción entre SOL, Empresa y Asesor, son presentadas. Su base de datos, los niveles de usuarios, sus funcionalidades, y la creación automatizada de información grafica y visual, también son explicadas. En el caso de aplicación, el uso de SOL para apoyar la toma de decisiones en una operación de movimiento de material, permite a los tomadores de decisión acceder a análisis robustos basados en información extraída de los modelos de simulación. SOL, al almacenar información, funcionar vía web, generar análisis automatizados y crear visualizaciones, permite cumplir con las expectativas de los usuarios respecto a una solución integral en simulación.

  2. Simplified automatic on-line document searching

    International Nuclear Information System (INIS)

    Ebinuma, Yukio

    1983-01-01

    The author proposed searching method for users who need not-comprehensive retrieval. That is to provide flexible number of related documents for the users automatically. A group of technical terms are used as search terms to express an inquiry. Logical sums of the terms in the ascending order of frequency of the usage are prepared sequentially and automatically, and then the search formulas, qsub(m) and qsub(m-1) which meet certain threshold values are selected automatically also. Users justify precision of the search output up to 20 items retrieved by the formula qsub(m). If a user wishes more than 30% of recall ratio, the serach result should be output by qsub(m), and if he wishes less than 30% of it, it should be output by qsub(m-1). The search by this method using one year volume of INIS Database (76,600 items) and five inquiries resulted in 32% of recall ratio and 36% of precision ratio on the average in the case of qsub(m). The connecting time of a terminal was within 15 minutes per an inquiry. It showed more efficiency than that of an inexperienced searcher. The method can be applied to on-line searching system for database in which natural language only or natural language and controlled vocabulary are used. (author)

  3. On-Line Impact Load Identification

    Directory of Open Access Journals (Sweden)

    Krzysztof Sekuła

    2013-01-01

    Full Text Available The so-called Adaptive Impact Absorption (AIA is a research area of safety engineering devoted to problems of shock absorption in various unpredictable scenarios of collisions. It makes use of smart technologies (systems equipped with sensors, controllable dissipaters and specialised tools for signal processing. Examples of engineering applications for AIA systems are protective road barriers, automotive bumpers or adaptive landing gears. One of the most challenging problems for AIA systems is on-line identification of impact loads, which is crucial for introducing the optimum real-time strategy of adaptive impact absorption. This paper presents the concept of an impactometer and develops the methodology able to perform real-time impact load identification. Considered dynamic excitation is generated by a mass M1 impacting with initial velocity V0. An analytical formulation of the problem, supported with numerical simulations and experimental verifications is presented. Two identification algorithms based on measured response of the impacted structure are proposed and discussed. Finally, a concept of the AIA device utilizing the idea of impactometer is briefly presented.

  4. Application of on-line analytical processing technique in accelerator

    International Nuclear Information System (INIS)

    Xie Dong; Li Weimin; He Duohui; Liu Gongfa; Xuan Ke

    2005-01-01

    A method of application of the on-line analytical processing technique in accelerator is described, which includes data pre-processing, the process of constructing of data warehouse and on-line analytical processing. (authors)

  5. Simultaneous Determination of Palladium and Platinum by On-line ...

    African Journals Online (AJOL)

    NJD

    using high performance liquid chromatography equipped with an on-line enrichment technique. Prior to ... The on-line enrichment system (Waters Corporation, USA) that was ... Using an appropriate volume (industrial plant effluents 20 mL,.

  6. A combination of positive dielectrophoresis driven on-line enrichment and aptamer-fluorescent silica nanoparticle label for rapid and sensitive detection of Staphylococcus aureus.

    Science.gov (United States)

    Shangguan, Jingfang; Li, Yuhong; He, Dinggeng; He, Xiaoxiao; Wang, Kemin; Zou, Zhen; Shi, Hui

    2015-07-07

    Staphylococcus aureus (S. aureus) is an important human pathogen that causes several diseases ranging from superficial skin infections to life-threatening diseases. Here, a method combining positive dielectrophoresis (pDEP) driven on-line enrichment and aptamer-fluorescent silica nanoparticle label has been developed for the rapid and sensitive detection of S. aureus in microfluidic channels. An aptamer, having high affinity to S. aureus, is used as the molecular recognition tool and immobilized onto chloropropyl functionalized fluorescent silica nanoparticles through a click chemistry approach to obtain S. aureus aptamer-nanoparticle bioconjugates (Apt(S.aureus)/FNPs). The pDEP driven on-line enrichment technology was used for accumulating the Apt(S.aureus)/FNP labeled S. aureus. After incubating with S. aureus, the mixture of Apt(S.aureus)/FNP labeled S. aureus and Apt(S.aureus)/FNPs was directly introduced into the pDEP-based microfluidic system. By applying an AC voltage in a pDEP frequency region, the Apt(S.aureus)/FNP labelled S. aureus moved to the electrodes and accumulated in the electrode gap, while the free Apt(S.aureus)/FNPs flowed away. The signal that came from the Apt(S.aureus)/FNP labelled S. aureus in the focused detection areas was then detected. Profiting from the specificity of aptamer, signal amplification of FNP label and pDEP on-line enrichment, this assay can detect as low as 93 and 270 cfu mL(-1)S. aureus in deionized water and spiked water samples, respectively, with higher sensitivities than our previously reported Apt(S.aureus)/FNP based flow cytometry. Moreover, without the need for separation and washing steps usually required for FNP label involved bioassays, the total assay time including sample pretreatment was within 2 h.

  7. Influence of visualization on consumption during on-line shopping

    OpenAIRE

    Hictaler, Urška

    2013-01-01

    This diploma work studies the influence of visualization on consumption during on-line shopping. The first part of the thesis starts with key areas of visualization, consumption and on-line shopping. Visualization, areas of use, human perception and ways of product presentation in on-line shops are defined discussed first. Next, consumption, consumers and factors that influence their decisions and satisfaction are defined. The last topic in the first part of the thesis discusses on-line shopp...

  8. A Distributed System for Learning Programming On-Line

    Science.gov (United States)

    Verdu, Elena; Regueras, Luisa M.; Verdu, Maria J.; Leal, Jose P.; de Castro, Juan P.; Queiros, Ricardo

    2012-01-01

    Several Web-based on-line judges or on-line programming trainers have been developed in order to allow students to train their programming skills. However, their pedagogical functionalities in the learning of programming have not been clearly defined. EduJudge is a project which aims to integrate the "UVA On-line Judge", an existing…

  9. Comparative study on microwave and conventional hydrothermal pretreatment of bamboo sawdust: Hydrochar properties and its pyrolysis behaviors

    International Nuclear Information System (INIS)

    Dai, Leilei; He, Chao; Wang, Yunpu; Liu, Yuhuan; Yu, Zhenting; Zhou, Yue; Fan, Liangliang; Duan, Dengle

    2017-01-01

    Highlights: • Two pretreatments affect differently the hydrochar properties and its pyrolysis behaviors. • Hydrochar by conventional hydrothermal pretreatment shows higher thermal stability. • Microwave hydrothermal pretreatment removes more acetyl. • Hydrochar by microwave hydrothermal pretreatment produces more glucopyranose and less acids. - Abstract: Comparative study on microwave and conventional hydrothermal pretreatment of bamboo sawdust was carried out in this study. Microwave and conventional hydrothermal pretreatment both improved the hydrochar properties and its pyrolysis behaviors. Proximate and elemental analyses show that the properties of hydrochar from microwave hydrothermal pretreatment are better than conventional hydrothermal pretreatment in terms of calorific value and oxygen content except for 150 °C. Microwave hydrothermal pretreatment removes more acetyl groups in hemicellulose compared to conventional hydrothermal pretreatment, which may be attributed to the hot spot effect of microwave irradiation. The peaks of thermogravimetric and derivative thermogravimetric curves of pretreated samples always shifted to higher temperature region. Also, the conventional hydrothermal pretreated samples are more thermally stable than those by microwave heating. In addition, the glucopyranose content in pyrolysis vapors of microwave hydrothermal pretreated bamboo sawdust (190 °C) was 9.82% higher than that from conventional hydrothermal pretreated bamboo sawdust. However, the acids content from microwave hydrothermal pretreated bamboo sawdust (150 °C) was 4.12% lower. In this regard, microwave hydrothermal pretreatment is more suitable for upgrading the pyrolysis oil quality than conventional hydrothermal pretreatment.

  10. Investigation of Pleurotus ostreatus pretreatment on switchgrass for ethanol production

    Science.gov (United States)

    Slavens, Shelyn Gehle

    Fungal pretreatment using the white-rot fungus Pleurotus ostreatus on switchgrass for ethanol production was studied. In a small-scale storage study, small switchgrass bales were inoculated with fungal spawn and automatically watered to maintain moisture. Sampled at 25, 53, and 81 d, the switchgrass composition was determined and liquid hot water (LHW) pretreatment was conducted. Fungal pretreatment significantly decreased the xylan and lignin content; glucan was not significantly affected by fungal loading. The glucan, xylan, and lignin contents significantly decreased with increased fungal pretreatment time. The effects of the fungal pretreatment were not highly evident after the LHW pretreatment, showing only changes based on sampling time. Although other biological activity within the bales increased cellulose degradation, the fungal pretreatment successfully reduced the switchgrass lignin and hemicellulose contents. In a laboratory-scale nutrient supplementation study, copper, manganese, glucose, or water was added to switchgrass to induce production of ligninolytic enzymes by P. ostreatus. After 40 d, ligninolytic enzyme activities and biomass composition were determined and simultaneous saccharification and fermentation (SSF) was conducted to determine ethanol yield. Laccase activity was similar for all supplements and manganese peroxidase (MnP) activity was significantly less in copper-treated samples than in the other fungal-inoculated samples. The fungal pretreatment reduced glucan, xylan, and lignin content, while increasing extractable sugars content. The lowest lignin contents occurred in the water-fungal treated samples and produced the greatest ethanol yields. The greatest lignin contents occurred in the copper-fungal treated samples and produced the lowest ethanol yields. Manganese-fungal and glucose-fungal treated samples had similar, intermediate lignin contents and produced similar, intermediate ethanol yields. Ethanol yields from switchgrass

  11. Biomass shock pretreatment

    Science.gov (United States)

    Holtzapple, Mark T.; Madison, Maxine Jones; Ramirez, Rocio Sierra; Deimund, Mark A.; Falls, Matthew; Dunkelman, John J.

    2014-07-01

    Methods and apparatus for treating biomass that may include introducing a biomass to a chamber; exposing the biomass in the chamber to a shock event to produce a shocked biomass; and transferring the shocked biomass from the chamber. In some aspects, the method may include pretreating the biomass with a chemical before introducing the biomass to the chamber and/or after transferring shocked biomass from the chamber.

  12. Semi-continuous on-line uranium ore analyzer

    International Nuclear Information System (INIS)

    Campbell, P.; Gurdy, E.M.; Hatchowski, L.

    1984-01-01

    The efficient process control of a uranium mill and its associated mining operation requires a nearly continuous knowledge of the uranium concentration in the ore. Generally, the approach is to use laboratory assays of grab samples from the mill feed belt. In some cases, elaborate and expensive systems have been used to ensure random sampling, but even with these systems, mass-balance discrepancies still exist. There is a requirement for an on-line instrument that can give a prompt, accurate analysis of a large portion of the feed stock. The authors have recently evaluated a laboratory system that achieves these goals using neutron activation and delayed neutron counting. The development of the on-line uranium ore analyzer is a consequence of previous work done at the Whiteshell Nuclear Research Establishment (WNRE) (Campbell et al., 1978 and 1981), and is based on the emission of delayed neutrons after the neutron irradiation of fissionable materials. The mechanism of delayed neutron emission has been described (Keepin, 1965), but briefly is as follows. The fission fragments resulting from irradiation are in an excited state. Certain of these delayed fission products, precursors, decay to a more stable state by the emission of a delayed neutron. The delayed neutrons can be divided into six groups with effective half-lives ranging from 0.2-55 sec. It is important to note that more than 50% of the delayed neutrons are emitted within the first 6 sec after irradiation; this has an influence on the design of the analysis instrument

  13. The current role of on-line extraction approaches in clinical and forensic toxicology.

    Science.gov (United States)

    Mueller, Daniel M

    2014-08-01

    In today's clinical and forensic toxicological laboratories, automation is of interest because of its ability to optimize processes, to reduce manual workload and handling errors and to minimize exposition to potentially infectious samples. Extraction is usually the most time-consuming step; therefore, automation of this step is reasonable. Currently, from the field of clinical and forensic toxicology, methods using the following on-line extraction techniques have been published: on-line solid-phase extraction, turbulent flow chromatography, solid-phase microextraction, microextraction by packed sorbent, single-drop microextraction and on-line desorption of dried blood spots. Most of these published methods are either single-analyte or multicomponent procedures; methods intended for systematic toxicological analysis are relatively scarce. However, the use of on-line extraction will certainly increase in the near future.

  14. Robust on-line monitoring of biogas processes; Robusta maettekniker on-line foer optimerad biogasproduktion

    Energy Technology Data Exchange (ETDEWEB)

    Nordberg, Aake; Hansson, Mikael; Kanerot, Mija; Krozer, Anatol; Loefving, Bjoern; Sahlin, Eskil

    2010-03-15

    Although demand for biomethane in Sweden is higher than ever, many Swedish codigestion plants are presently operated below their designed capacity. Efforts must be taken to increase the loading rate and guarantee stable operation and high availability of the plants. There are currently no commercial systems for on-line monitoring, and due to the characteristics of the material, including corrosion and tearing, robust applications have to be developed. The objective of this project was to identify and study different monitoring technologies with potential for on-line monitoring of both substrate mixtures and anaerobic digester content. Based on the prerequisites and demands at Boraas Energi och Miljoe AB's (BEMAB, the municipal energy and waste utility in the city of Boraas, Sweden) biogas plant, the extent of the problems, measurement variables and possible ways of managing these issues have been identified and prioritized. The substrate mixtures in question have a high viscosity and are inhomogeneous with variation in composition, which calls for further homogenization, dilution and filtration to achieve high precision in the necessary analyses. Studies of using different mixers and mills showed that the particle size (800 mum) needed for on-line COD measurement could not be achieved. The problem of homogenization can be avoided if indirect measurement methods are used. Laboratory tests with NIR (near-infra red spectroscopy) showed that VS can be predicted (R2=0,78) in the interval of 2-9% VS. Furthermore, impedance can give a measurement of soluble components. However, impedance is not sensitive enough to give a good measurement of total TS. Microwave technology was installed at the production plant and showed a faster response to changes in TS than the existing TS-sensor. However, due to technical problems, the evaluation only could be done during a limited period of ten days. BEMAB will continue the measurements and evaluation of the instrument. The

  15. Comparison of gamma irradiation and steam explosion pretreatment for ethanol production from agricultural residues

    International Nuclear Information System (INIS)

    Wang, Ke-qin; Xiong, Xing-yao; Chen, Jing-ping; Chen, Liang; Su, Xiaojun; Liu, Yun

    2012-01-01

    It was evaluated the influence of gamma irradiation and steam explosion pretreatment on the components and the water-soluble sugars of rice straw. Compared with the steam explosion pretreated rice straw, cellucose, hemicellucose and lignin for irradiation pretreated rice sample were much more greatly degraded and the relative content of glucose was significantly enhanced from 6.58% to 47.44%. Interestingly, no glucuronide acid was detected in irradiation pretreated rice straw, while glucuronide acid with the content from 8.5 mg/g to 9.2 mg/g was obtained in steam explosion pretreated sample. Followed by enzymatic hydrolysis, higher concentration of reducing sugars (including glucose and xylose) of irradiation pretreated rice sample (90.3 mg/g) was obtained, which was approximately 2.4- and 1.1- fold higher of the unpretreated (37.2 mg/g) and of steam explosion pretreated sample (85.4 mg/g). To further verify the effectiveness of irradiation pretreatment, characterizations of rice straw, corn stalk and bagasse by an integrated process of dilute acid/enzymatic hydrolysis and irradiation pretreatment were also investigated. -- Highlights: ► We compare irradiation and steam explosion pretreatments for bioethanol production. ► We examine changes in compositions of the components and the water-soluble sugars. ► No glucuronide acid was detected in gamma irradiation pretreated rice straw. ► We evaluate an integrated method of acid/enzyme-hydrolyzed irradiation pretreatment.

  16. On-line milk spectrometry: analysis of bovine milk composition

    Science.gov (United States)

    Spitzer, Kyle; Kuennemeyer, Rainer; Woolford, Murray; Claycomb, Rod

    2005-04-01

    We present partial least squares (PLS) regressions to predict the composition of raw, unhomogenised milk using visible to near infrared spectroscopy. A total of 370 milk samples from individual quarters were collected and analysed on-line by two low cost spectrometers in the wavelength ranges 380-1100 nm and 900-1700 nm. Samples were collected from 22 Friesian, 17 Jersey, 2 Ayrshire and 3 Friesian-Jersey crossbred cows over a period of 7 consecutive days. Transmission spectra were recorded in an inline flowcell through a 0.5 mm thick milk sample. PLS models, where wavelength selection was performed using iterative PLS, were developed for fat, protein, lactose, and somatic cell content. The root mean square error of prediction (and correlation coefficient) for the nir and visible spectrometers respectively were 0.70%(0.93) and 0.91%(0.91) for fat, 0.65%(0.5) and 0.47%(0.79) for protein, 0.36%(0.49) and 0.45%(0.43) for lactose, and 0.50(0.54) and 0.48(0.51) for log10 somatic cells.

  17. On-line bacteriological detection in water

    OpenAIRE

    Lopez Roldan, Ramon; Tusell, Pol; Courtois, Sophie; Cortina Pallás, José Luís

    2013-01-01

    Microorganism contamination is a permanent concern in a wide range of fields, including the water-treatment, food and pharmaceutical industries, in which fast detection is critical to prevent microbial outbreaks. In water monitoring, current procedures for water-quality analysis are based on periodic sampling and detection by culture methods, which are slow, requiring 24–48 h for completion, so that, when first results reach the decision-takers and trigger an alarm, significant time has a...

  18. DOE-EPRI On-Line Monitoring Implementation Guidelines

    International Nuclear Information System (INIS)

    E. Davis, R. Bickford

    2003-01-01

    Industry and EPRI experience at several plants has shown on-line monitoring to be very effective in identifying out-of-calibration instrument channels or indications of equipment-degradation problems. The EPRI implementation project for on-line monitoring has demonstrated the feasibility of on-line monitoring at several participating nuclear plants. The results have been very encouraging, and substantial progress is anticipated in the coming years

  19. Review of Worcestershire On-line Fabric Type Series website

    Directory of Open Access Journals (Sweden)

    Beverley Nenk

    2003-06-01

    Full Text Available The study of archaeological ceramics is advanced through the creation and development of regional and national pottery type-series, which contain samples of each type of pottery identified from a particular area or region. Pottery researchers working in any period, from prehistoric to post-medieval, require access to such type-series, and to their associated data, in order to be able to advance the identification of all types of pottery, not only those types produced in the local area, but those produced in surrounding regions, as well as those imported from abroad. The publication of such type-series, as well as their accessibility to researchers, is essential if the information they contain is to be disseminated. The development of the Worcestershire On-Line Fabric Type Series is the first stage in a remarkable project designed to make the complete fabric and form type series for Worcestershire ceramics accessible on the internet. As part of the Historic Environment Record for Worcestershire, formerly the Sites and Monuments Record, it is designed to improve access to finds and environmental data, with the aim of encouraging and facilitating research. Funded by Worcestershire County Council as part of its commitment to e-government, it is being developed by Worcestershire County Council Archaeology Service with OxfordArchDigital. It is one of a proposed series of on-line specialist resources (to include, for example, clay pipes, environmental archaeology, flint tools, historic buildings, which are also designed to stand alone as research tools. The ceramics website is the first part of Pottery in Perspective, a web-based project to provide information on the pottery used and made in Worcestershire from prehistory to c. 1900AD.

  20. Purity, adulteration and price of drugs bought on-line versus off-line in the Netherlands.

    Science.gov (United States)

    van der Gouwe, Daan; Brunt, Tibor M; van Laar, Margriet; van der Pol, Peggy

    2017-04-01

    On-line drug markets flourish and consumers have high expectations of on-line quality and drug value. The aim of this study was to (i) describe on-line drug purchases and (ii) compare on-line with off-line purchased drugs regarding purity, adulteration and price. Comparison of laboratory analyses of 32 663 drug consumer samples (stimulants and hallucinogens) purchased between January 2013 and January 2016, 928 of which were bought on-line. The Netherlands. Primary outcome measures were (i) the percentage of samples purchased on-line and (ii) the chemical purity of powders (or dosage per tablet); adulteration; and the price per gram, blotter or tablet of drugs bought on-line compared with drugs bought off-line. The proportion of drug samples purchased on-line increased from 1.4% in 2013 to 4.1% in 2015. The frequency varied widely, from a maximum of 6% for controlled, traditional substances [ecstasy tablets, 3,4-methylenedioxy-methamphetamine (MDMA) powder, amphetamine powder, cocaine powder, 4-bromo-2,5-dimethoxyphenethylamine (2C-B) and lysergic acid diethylamide (LSD)] to more than a third for new psychoactive substances (NPS) [4-fluoroamphetamine (4-FA), 5/6-(2-aminopropyl)benzofuran (5/6-APB) and methoxetamine (MXE)]. There were no large differences in drug purity, yet small but statistically significant differences were found for 4-FA (on-line 59% versus off-line 52% purity for 4-FA on average, P = 0.001), MDMA powders (45 versus 61% purity for MDMA, P = 0.02), 2C-B tablets (21 versus 10 mg 2C-B/tablet dosage, P = 0.49) and ecstasy tablets (131 versus 121 mg MDMA/tablet dosage, P = 0.05). The proportion of adulterated samples purchased on-line and off-line did not differ, except for 4-FA powder, being less adulterated on-line (χ 2  = 8.3; P < 0.02). Drug prices were mainly higher on-line, ranging for various drugs from 10 to 23% higher than that of drugs purchased off-line (six of 10 substances: P < 0.05). Dutch drug users increasingly

  1. Electrolytic pretreatment of urine

    Science.gov (United States)

    1977-01-01

    Electrolysis has been under evaluation for several years as a process to pretreat urine for ultimate recovery of potable water in manned spacecraft applications. The conclusions that were drawn from this investigation are the following: (1) A platinum alloy containing 10 percent rhodium has been shown to be an effective, corrosion-resistant anode material for the electrolytic pretreatment of urine. Black platinum has been found to be suitable as a cathode material. (2) The mechanism of the reactions occurring during the electrolysis of urine is two-stage: (a) a total Kjeldahl nitrogen and total organic carbon (TOC) removal in the first stage is the result of electrochemical oxidation of urea to CO2, H2O, and ammonia followed by chloride interaction to produce N2 from ammonia, (b) after the urea has been essentially removed and the chloride ions have no more ammonia to interact with, the chloride ions start to oxidize to higher valence states, thus producing perchlorates. (3) Formation of perchlorates can be suppressed by high/low current operation, elevated temperature, and pH adjustment. (4) UV-radiation showed promise in assisting electrolytic TOC removal in beaker tests, but was not substantiated in limited single cell testing. This may have been due to non-optimum configurations of the single cell test rig and the light source.

  2. Pretreatment of Oil Palm Frond (OPF) with Ionic Liquid

    Science.gov (United States)

    Azmi, I. S.; Azizan, A.; Salleh, R. Mohd

    2018-05-01

    Pretreatment is the key to unlock the recalcitrance of lignocellulose for cellulosic biofuel production. Increasing attention has been drawn to ionic liquids (ILs) for pretreatment of lignocellulosic biomass because this approach was considered as a green engineering method over other conventional methods. In this work, Oil palm frond (OPF) was pretreated by using the ionic liquid 1-ethyl-3-methylimidazolium acetate [EMIM] Ac at the temperature of 99˚C for 3 hours. The characterization of the untreated and pretreated OPF was conducted by using different techniques which are Fourier Transform Infrared Spectroscopy (FTIR), X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM). The pretreatment of OPF with [EMIM] Ac was demonstrated to be effective evidenced by the significant reduction of Lateral Order Index (LOI) from FTIR, reduction of Crystallinity Index (CI) based on XRD and the significant morphology changes indicated by SEM. The CI value for the pretreated OPF decreased from 0.47 (untreated sample) to 0.28 while the LOI value decreased from 1.10 to 0.24 after pretreatment with [EMIM]Ac and the SEM morphology showed that the pretreated OPF becomes distorted and disordered.

  3. Lignocellulosic Biomass Pretreatment Using AFEX

    Science.gov (United States)

    Balan, Venkatesh; Bals, Bryan; Chundawat, Shishir P. S.; Marshall, Derek; Dale, Bruce E.

    Although cellulose is the most abundant organic molecule, its susceptibility to hydrolysis is restricted due to the rigid lignin and hemicellulose protection surrounding the cellulose micro fibrils. Therefore, an effective pretreatment is necessary to liberate the cellulose from the lignin-hemicellulose seal and also reduce cellulosic crystallinity. Some of the available pretreatment techniques include acid hydrolysis, steam explosion, ammonia fiber expansion (AFEX), alkaline wet oxidation, and hot water pretreatment. Besides reducing lignocellulosic recalcitrance, an ideal pretreatment must also minimize formation of degradation products that inhibit subsequent hydrolysis and fermentation. AFEX is an important pretreatment technology that utilizes both physical (high temperature and pressure) and chemical (ammonia) processes to achieve effective pretreatment. Besides increasing the surface accessibility for hydrolysis, AFEX promotes cellulose decrystallization and partial hemicellulose depolymerization and reduces the lignin recalcitrance in the treated biomass. Theoretical glucose yield upon optimal enzymatic hydrolysis on AFEX-treated corn stover is approximately 98%. Furthermore, AFEX offers several unique advantages over other pretreatments, which include near complete recovery of the pretreatment chemical (ammonia), nutrient addition for microbial growth through the remaining ammonia on pretreated biomass, and not requiring a washing step during the process which facilitates high solid loading hydrolysis. This chapter provides a detailed practical procedure to perform AFEX, design the reactor, determine the mass balances, and conduct the process safely.

  4. On-line nuclear analysis of coal (Nucoalyzer)

    International Nuclear Information System (INIS)

    Brown, D.R.; Gozani, T.; Bozorgmanesh, H.

    1980-01-01

    Control of quality in the coal process stream is increasingly important in both coal preparation facilities and coal fire power plants. Traditional wet chemistry methods of monitoring coal composition are incapable of providing anything approaching real-time analysis of coal. Typically, small samples of the coal stream are laboratory analyzed and the results made available between a day to a week later. By this time the coal is through the process stream, often already burned and no control is possible. The need of real-time analysis of bulk quantities of the coal has long been recognized and this need motivated Science Applications, Inc. to develop, since 1975, a continuous on-line nuclear analyzer of coal (or CONAC). Over the last three years a prototype of this instrument has undergone extensive testing using 200 pound bulk samples of a wide variety of US coal types. The Nucoalyzer has proven capable of measuring the abundances of all the important elemental constituents of coal along with the ash and calorific value. In the past year the first instrument has been installed and undergone testing at Detroit Edison's Monroe Coal blending facility, where it will control the blending of high and low sulfur coal to meet EPA emission regulations

  5. On-line radioactivity detector for HPLC

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1986-01-01

    Over the last ten years the technique of high performance liquid chromotography (HPLC) has become extensively employed for the separation and quantitation of various biological, organic, and inorganic substances. The use of HPLC for the separation of various metabolic compounds has become routine. The major problem of analyzing the metabolism process is that the quantitation is accomplished by the use of radioactive substrates. Until recently the only method to quantitate these radioactive compounds eluting from the HPLC was by collecting fractions at preset times, removing aliquots and quantitating in a liquid scintillation counter. Once the radioactivity present in each fraction was determined, the results were plotted on a graph and the area of each of the radioactive peaks was determined. This entire process required from 3-20 hours. The introduction of the flow through radioactivity detector enable the investigator to directly quantitate the radioactive peaks as they elute from the HPLC in real time and at about one-tenth the original cost of the previous methods. The detection limits of this technique are dependent on the residence time of the sample in the flow cell and the type of flow cell used for the analysis. Using a 2.5 ml liquid flow cell, (mixing with liquid scintillation solution), base line resolution can be obtained for peaks 1.5 minutes apart, and a sensitivity of 70 dpm for tritium and 30 dpm for carbon-14 can be achieved

  6. Algorithms for the on-line travelling salesman

    NARCIS (Netherlands)

    Ausiello, G.; Feuerstein, E.; Leonardi, S.; Stougie, L.; Talamo, M.

    1999-01-01

    In this paper the problem of efficiently serving a sequence of requests presented in an on-line fashion located at points of a metric space is considered. We call this problem the On-Line Travelling Salesman Problem (OLTSP). It has a variety of relevant applications in logistics and robotics. We

  7. An algorithm for on-line price discrimination

    NARCIS (Netherlands)

    D.D.B. van Bragt; D.J.A. Somefun (Koye); E. Kutschinski; J.A. La Poutré (Han)

    2002-01-01

    textabstractThe combination of on-line dynamic pricing with price discrimination can be very beneficial for firms operating on the Internet. We therefore develop an on-line dynamic pricing algorithm that can adjust the price schedule for a good or service on behalf of a firm. This algorithm (a

  8. On-Line Voltage Stability Assessment based on PMU Measurements

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Nielsen, Arne Hejde

    2009-01-01

    This paper presents a method for on-line monitoring of risk voltage collapse based on synchronised phasor measurement. As there is no room for intensive computation and analysis in real-time, the method is based on the combination of off-line computation and on-line monitoring, which are correlat...

  9. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  10. On-line Learning of Prototypes and Principal Components

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Hölzer, M.; Reents, G.; Schlösser, E.; Saad, David

    1998-01-01

    We review our recent investigation of on-line unsupervised learning from high-dimensional structured data. First, on-line competitive learning is studied as a method for the identification of prototype vectors from overlapping clusters of examples. Specifically, we analyse the dynamics of the

  11. On-line stable isotope measurements during plant and soil gas exchange

    International Nuclear Information System (INIS)

    Yakir, D.

    2001-01-01

    Recent techniques for on-line stable isotope measurements during plant and soil exchange of CO 2 and/or water vapor are briefly reviewed. For CO 2 , these techniques provide means for on-line measurements of isotopic discrimination during CO 2 exchange by leaves in the laboratory and in the field, of isotopic discrimination during soil respiration and during soil-atmosphere CO 2 exchange, and of isotopic discrimination in O 2 during plant respiration. For water vapor, these techniques provide means to measure oxygen isotopic composition of water vapor during leaf transpiration and for the analysis of sub microliter condensed water vapor samples. Most of these techniques involve on-line sampling of CO 2 and water vapor from a dynamic, intact soil or plant system. In the laboratory, these systems also allow on-line isotopic analysis by continuous-flow isotope ratio mass spectrometry. The information obtained with these on-line techniques is becoming increasingly valuable, and often critical, for ecophysiologial research and in the study of biosphere-atmosphere interactions. (author)

  12. Unattended reaction monitoring using an automated microfluidic sampler and on-line liquid chromatography.

    Science.gov (United States)

    Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve

    2018-04-03

    In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Determination of Peroxide-Based Explosives Using Liquid Chromatography with On-Line Infrared Detection

    NARCIS (Netherlands)

    Schulte-Ladbeck, Rasmus; Edelmann, Andrea; Quintas, Guillermo; Lendl, Bernhard; Karst, U.

    2006-01-01

    A nondestructive analytical method for peroxide-based explosives determination in solid samples is described. Reversed-phase high-performance liquid chromatography in combination with on-line Fourier transform infrared (FT-IR) detection is used for the analysis of triacetonetriperoxide (TATP) and

  14. In Their Words: Connecting On-Line Weblogs to Developmental Processes

    Science.gov (United States)

    Subrahmanyam, Kaveri; Garcia, Eddie C. M.; Harsono, Lidwina Stella; Li, Janice S.; Lipana, Lawrence

    2009-01-01

    This paper seeks to connect adolescents' communication within on-line weblogs or blogs to developmental processes. A total of 195 English language blogs written by self-identified 14- to 18-year-olds were selected; three entries from each blog were analysed, resulting in a sample of 585 entries. Blogger demographics, self-presentation, and blog…

  15. Design and construction of an on-line SPE-SFE-CGC system

    Directory of Open Access Journals (Sweden)

    Pinto Jair S. S.

    2001-01-01

    Full Text Available The construction of an on-line SPE-SFE-CGC system is described. The home-made system is of low cost and of easy construction and maintenance, making possible the analysis of organic micropollutants in liquid samples such as water in a fraction of the time spent using traditional methods.

  16. The characteristic changes of betung bamboo (Dendrocalamus asper pretreated by fungal pretreatment

    Directory of Open Access Journals (Sweden)

    Widya Fatriasari

    2014-05-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 The fungal pretreatment effect on chemical structural and morphological changes of Betung Bamboo was evaluated based on its biomass components after being cultivated by white rot fungi, Trametes versicolor. Betung bamboo powder (15 g was exposed to liquid inoculum of white rot fungi and incubated at 270C for 15, 30 and 45 days. The treated samples were then characterized by FT-IR spectroscopy, X-Ray diffraction and SEM-EDS analyses. Cultivation for 30 days with 5 and 10% loadings retained greater selectivity compared to that of the other treatments. FTIR spectra demonstrated that the fungus affected the decreasing of functional group quantities without changing the functional groups. The decrease in intensity at wave number of 1246 cm-1 (guaiacyl of lignin was greater than that at wave number of 1328 cm-1 (deformation combination of syringyl and xylan after fungal treatment. X-ray analysis showed the pretreated samples had a higher crystallinity than the untreated ones which might be due to the cleavage of amorphous fractions of cellulose. The pretreated samples have more fragile than the untreated ones confirmed by SEM. Crystalline allomorph calculated by XRD analysis showed that fungus pretreatment for 30 days has transformed triclinic structure of cellulose to monoclinic structure.

  17. Improving enzymatic saccharification of cassava stem using peroxide and microwave assisted pre-treatment techniques

    Directory of Open Access Journals (Sweden)

    Sudha A.

    2017-01-01

    Full Text Available The effectiveness of microwave assisted alkali (MAA and alkaline hydrogen peroxide (AHP pre-treatment methods in improving the enzymatic saccharification of cassava stem was investigated. Ground cassava stems were by MAA method by varying microwave power, NaOH concentration and pre-treatment time. AHP method was performed at various H2O2 concentrations, pre-treatment temperatures and times. The results showed that reducing sugar yield was higher from MAA pretreated stem when compared with AHP pre-treatment, which demonstrated that MAA pre-treatment was effective in releasing sugars. SEM studies on the pre-treated samples revealed extensive distortion of fibres in MAA pre-treated than AHP pre-treated samples, which showed pores and cracks in the fibrous structure. Spectral studies showed the change in the chemical structure of pre-treated samples. The work revealed that the studied pre-treatment methods were effective in improving the enzymatic saccharification of cassava stem.

  18. On-line monitoring of low-level plutonium concentrations

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Huff, G.A.; Rebagay, T.V.

    1979-10-01

    An on-line monitor has been developed to assay plutonium in nitric acid solutions. The performance of the monitor has been assessed by a laboratory experimentation program using solutions with plutonium concentrations from 0.1 to 10 g/l. These conditions are typical of the plutonium solutions in an input stream to a plutonium-purification cycle in a reprocessing plant following uranium/plutonium partitioning. The monitoring system can be fully automated and shows great promise for detecting and quantifying plutonium in situ, thus minimizing the reliance on traditional sampling and laboratory-analysis techniques. The total concentration and isotopic abundance of plutonium are determined by measuring the absolute intensities of the low-energy gamma rays characteristics of 238 Pu, 239 Pu, and 240 Pu nuclides by direct gamma-ray spectroscopy and computer analysis of the spectral data. The addition of a monitoring system of this type to the input stream of a plutonium-purification cycle along with other suitable monitors on the waste streams and on the product stream provides the basis for a near real-time materials control and inventory system. Results of the laboratory-evaluation program employing plutonium in solutions with isotopic compositions typical of those involved in processing light water reactor fuels are presented. The detailed design of a monitoring cell and detection system is given. The precision and accuracy of the results relative to those measured by mass spectrometry and controlled potential coulometry are also summarized

  19. On-line monitoring of methane in sewer air.

    Science.gov (United States)

    Liu, Yiwen; Sharma, Keshab R; Murthy, Sudhir; Johnson, Ian; Evans, Ted; Yuan, Zhiguo

    2014-10-16

    Methane is a highly potent greenhouse gas and contributes significantly to climate change. Recent studies have shown significant methane production in sewers. The studies conducted so far have relied on manual sampling followed by off-line laboratory-based chromatography analysis. These methods are labor-intensive when measuring methane emissions from a large number of sewers, and do not capture the dynamic variations in methane production. In this study, we investigated the suitability of infrared spectroscopy-based on-line methane sensors for measuring methane in humid and condensing sewer air. Two such sensors were comprehensively tested in the laboratory. Both sensors displayed high linearity (R(2) > 0.999), with a detection limit of 0.023% and 0.110% by volume, respectively. Both sensors were robust against ambient temperature variations in the range of 5 to 35°C. While one sensor was robust against humidity variations, the other was found to be significantly affected by humidity. However, the problem was solved by equipping the sensor with a heating unit to increase the sensor surface temperature to 35°C. Field studies at three sites confirmed the performance and accuracy of the sensors when applied to actual sewer conditions, and revealed substantial and highly dynamic methane concentrations in sewer air.

  20. An on-line tritium-in-water monitor

    International Nuclear Information System (INIS)

    Singh, A.N.; Ratnakaran, M.; Vohra, K.G.

    1985-01-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2 . In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 x 10 4 Bq/cm 3 (1 μCi/cm 3 ) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line. (orig.)

  1. An on-line tritium-in-water monitor

    Science.gov (United States)

    Singh, A. N.; Ratnakaran, M.; Vohra, K. G.

    1985-05-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2. In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 × 10 4 Bq/cm 3 (1 μCi/cm 3) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line.

  2. El aprendizaje on-line: oportunidades y retos en instituciones politécnicas Apprenticeship Students Learning On-line: Opportunities and Challenges for Polytechnic Institutions

    Directory of Open Access Journals (Sweden)

    Martha Burkle

    2011-10-01

    challenges and opportunities of delivering on-line and virtual content to apprentices in a Polytechnic institution. Due to the current financial recession, apprentices are going back to academia in order to update their skills, but these potential students are not willing to leave their workplace or their personal lives behind to study. In this context on-line delivery represents an opportunity to provide access to content without leaving the work environment. However, in order to be successful in providing on-line materials for apprentices, polytechnics around the world are facing two challenges: How to transform hands-on Learning skills to online Learning material, and how to provide a rich-engaging environment for this group of learners. But not only the learner expectations should be taken when designing on-line learning. Instructors play also a crucial role in this endeavor, as Web 2.0 technologies offer the instructor an entirely new role in teaching: that of a facilitator. In order to analyze apprenticeship students’ on-line learning, 57 on-line surveys were distributed among a group of students registered for on-line apprenticeship programs. The paper presents research findings and a comparison of these with a what the literature states regarding the new generation of learners and their use of technologies, and the behavior (learning preferences, learning styles, use of IT presented by the research sample. Innovative opportunities for learning at the workplace (such as recommendations and future areas of research are suggested.

  3. Understanding on-line community: the affordances of virtual space

    Directory of Open Access Journals (Sweden)

    Karen Ruhleder

    2002-01-01

    Full Text Available Increasing numbers of on-line venues for learning are emerging as virtual communities become more accessible and commonplace. This paper looks at one particular virtual community, an on-line degree programme at the University of Illinois, Urbana-Champaign, which offers an M.S. in Library and Information Science (called LEEP. It draws on a framework presented by Mynatt, et al. (1998, which provides a lens for talking about on-line community as a set of affordances. This framework is applied to illustrate the interactions, artefacts, and expectations that shape this community.

  4. An Approach to On-line Risk Assessment in NPP

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; O'Brien, J.

    1996-01-01

    Probabilistic Risk Assessment (PRA) can provide safety status information for a plant during different configurations; additional effort is needed to do this in real time for on-line operation. This paper describes an approach to use PRA to achieve these goals. A Risk Assessment On-Line (RAOL) application was developed to monitor maintenance (on-line and planned) activities. RAOL is based on the results from a full-scope PRA, engineering/operational judgment and incorporates a user friendly program interface approach. Results from RAOL can be used by planners or operations to effectively manage the level of risk by controlling the actual plant configuration. (author)

  5. On-line spectroscopy with thermal atomic beams

    International Nuclear Information System (INIS)

    Thibault, C.; Guimbal, P.; Klapisch, R.; Saint Simon, M. de; Serre, J.M.; Touchard, F.; Duong, H.T.; Jacquinot, P.; Juncar, P.

    1981-01-01

    On-line high resolution laser spectroscopy experiments have been performed in which the light from a cw tunable dye laser interacts at right angles with a thermal atomic beam. sup(76-98)Rb, sup(118-145)Cs and sup(208-213)Fr have been studied using the ionic beam delivered by the ISOLDE on-line mass separator at CERN while sup(20-31)Na and sup(38-47)K have been studied by setting the apparaturs directly on-line with the PS 20 GeV proton beam. The principle of the method is briefly explained and some results concerning nuclear structure are given. (orig.)

  6. Comparison of On-Line Maintenance Support Tools

    International Nuclear Information System (INIS)

    Simic, Z.; Follen, S. M.; Mikulicic, V.

    1998-01-01

    Modeling approach to on-line risk monitoring is today in a rapid developing phase. For that reason number of different solutions are available. This paper will attempt to present existing approaches to address on-line risk modeling problem Starting with description of on-line risk monitoring issues in general, then following by presentation of existing software tools (EPRI's Safety Monitor, Equipment Out of Service Monitor, and ORAM-SENTINEL) the current state of the art in this area will be demonstrated. Finally, conclusions and ideas will be outlined. (author)

  7. A modular multi-microcomputer system for on-line vibration diagnostics

    International Nuclear Information System (INIS)

    Saedtler, E.

    1988-01-01

    A new modular multi-microprocessor system for on-line vibration monitoring and diagnostics of PWRs is described. The aim of the system is to make feasible an early detection of increasing failures in relevant regions of a reactor plant, to verify the mechanical integrity of the investigated components, and to improve therefore the operational safety of the plant. After a discussion of the implemented surveillance methods and algorithms, which are based on hierarchical structured identification (estimation) and statistical pattern recognition tools, the system architecture (software and hardware) is portrayed. The classification scheme itself works sequential so that samples (or features) can arrive on-line. This on-line classification is important in order to take necessary actions in time. Furthermore, the system has learning capabilities, which means it is adaptable to different, varying states and plant conditions. The main features of the system are presented and its contribution to an automation of complex surveillance and monitoring tasks is shown. (author)

  8. On-line methanol sensor system development for recombinant ...

    African Journals Online (AJOL)

    On-line methanol sensor system development for recombinant human serum ... of the methanol sensor system was done in a medium environment with yeast cells ... induction at a low temperature and a pH where protease does not function.

  9. On-line control systems in power plants

    International Nuclear Information System (INIS)

    Freymeyer, P.

    1981-01-01

    This report is a review of on-line control systems as a complex system connected with all problems like, development, planning, degree of automation, economics, service, quality and documentation. (orig.) [de

  10. Why do People Stop Playing On-Line Games?

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    2012-01-01

    The recent initial public offering of shares of Zynga, probably the most important on-line game provider, drew interest of potential investors but also of general public to their business model. What the most interested people learned so far is that if Zynga had not changed their accounting...... practice, they would be in red numbers for several months already. This is most likely caused by people stopping to play their games. This paper provides an estimate of what proportion of people, who played on-line games, already stopped playing them. Additionally, it analyzed the reasons why people...... stopped playing on-line games. It also compares Facebook and other on-line games....

  11. Identification of Variables and Factors Impacting Consumer Behavior in On-line Shopping in India: An Empirical Study

    Science.gov (United States)

    Chhikara, Sudesh

    On-line shopping is a recent phenomenon in the field of E-Business and is definitely going to be the future of shopping in the world. Most of the companies are running their on-line portals to sell their products/services. Though online shopping is very common outside India, its growth in Indian Market, which is a large and strategic consumer market, is still not in line with the global market. The potential growth of on-line shopping has triggered the idea of conducting a study on on-line shopping in India. The present research paper has used exploratory study to depict and highlight the various categories of factors and variables impacting the behavior of consumers towards on-line shopping in India. The data was collected through in-depth interviews on a sample of 41 respondents from Delhi, Mumbai, Chennai and Bangalore. The results of the study show that on-line shopping in India is basically impacted by five categories of factors like demographics factor, Psychographics factor, Online shopping feature and policies, Technological factor, Security factor. The results of the study are used to present a comprehensive model of on-line shopping which could be further used by the researchers and practitioners for conducting future studies in the similar area. A brief operational definition of all the factors and variables impacting on-line shopping in India is also described. And finally practical implications of the study are also elucidated.

  12. Mechanism of waste biomass pyrolysis: Effect of physical and chemical pre-treatments

    International Nuclear Information System (INIS)

    Das, Oisik; Sarmah, Ajit K.

    2015-01-01

    To impart usability in waste based biomass through thermo-chemical reactions, several physical and chemical pre-treatments were conducted to gain an insight on their mode of action, effect on the chemistry and the change in thermal degradation profiles. Two different waste biomasses (Douglas fir, a softwood and hybrid poplar, a hardwood) were subjected to four different pre-treatments, namely, hot water pre-treatment, torrefaction, acid (sulphuric acid) and salt (ammonium phosphate) doping. Post pre-treatments, the changes in the biomass structure, chemistry, and thermal makeup were studied through electron microscopy, atomic absorption/ultra violet spectroscopy, ion exchange chromatography, and thermogravimetry. The pre-treatments significantly reduced the amounts of inorganic ash, extractives, metals, and hemicellulose from both the biomass samples. Furthermore, hot water and torrefaction pre-treatment caused mechanical disruption in biomass fibres leading to smaller particle sizes. Torrefaction of Douglas fir wood yielded more solid product than hybrid poplar. Finally, the salt pre-treatment increased the activation energies of the biomass samples (especially Douglas fir) to a great extent. Thus, salt pre-treatment was found to bestow thermal stability in the biomass. - Highlights: • Pre-treatments reduce ash, extractives, alkalines and hemicellulose from biomass. • Torrefaction of Douglas fir yields more solid product than hybrid poplar. • Salt pretreatment significantly increases the activation energy of biomass. • Acid and salt pretreatment bestows thermal stability in biomass.

  13. Mechanism of waste biomass pyrolysis: Effect of physical and chemical pre-treatments

    Energy Technology Data Exchange (ETDEWEB)

    Das, Oisik [Department of Biological Systems Engineering, Washington State University, Pullman 99164-6120, WA (United States); Department of Civil and Environmental Engineering, University of Auckland, Auckland 1142 (New Zealand); Sarmah, Ajit K., E-mail: a.sarmah@auckland.ac.nz [Department of Civil and Environmental Engineering, University of Auckland, Auckland 1142 (New Zealand)

    2015-12-15

    To impart usability in waste based biomass through thermo-chemical reactions, several physical and chemical pre-treatments were conducted to gain an insight on their mode of action, effect on the chemistry and the change in thermal degradation profiles. Two different waste biomasses (Douglas fir, a softwood and hybrid poplar, a hardwood) were subjected to four different pre-treatments, namely, hot water pre-treatment, torrefaction, acid (sulphuric acid) and salt (ammonium phosphate) doping. Post pre-treatments, the changes in the biomass structure, chemistry, and thermal makeup were studied through electron microscopy, atomic absorption/ultra violet spectroscopy, ion exchange chromatography, and thermogravimetry. The pre-treatments significantly reduced the amounts of inorganic ash, extractives, metals, and hemicellulose from both the biomass samples. Furthermore, hot water and torrefaction pre-treatment caused mechanical disruption in biomass fibres leading to smaller particle sizes. Torrefaction of Douglas fir wood yielded more solid product than hybrid poplar. Finally, the salt pre-treatment increased the activation energies of the biomass samples (especially Douglas fir) to a great extent. Thus, salt pre-treatment was found to bestow thermal stability in the biomass. - Highlights: • Pre-treatments reduce ash, extractives, alkalines and hemicellulose from biomass. • Torrefaction of Douglas fir yields more solid product than hybrid poplar. • Salt pretreatment significantly increases the activation energy of biomass. • Acid and salt pretreatment bestows thermal stability in biomass.

  14. The Daresbury On-Line Isotope Separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described

  15. The Daresbury on-line isotope separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described. (orig.)

  16. On-line mixture-based alternative to logistic regression

    Czech Academy of Sciences Publication Activity Database

    Nagy, Ivan; Suzdaleva, Evgenia

    2016-01-01

    Roč. 26, č. 5 (2016), s. 417-437 ISSN 1210-0552 R&D Projects: GA ČR GA15-03564S Institutional support: RVO:67985556 Keywords : on-line modeling * on-line logistic regression * recursive mixture estimation * data dependent pointer Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.394, year: 2016 http://library.utia.cas.cz/separaty/2016/ZS/suzdaleva-0464463.pdf

  17. Simultaneous determination of 1- and 2-naphthol in human urine using on-line clean-up column-switching liquid chromatography-fluorescence detection.

    Science.gov (United States)

    Preuss, Ralf; Angerer, Jürgen

    2004-03-05

    We developed a new 3-D HPLC method for on-line clean-up and simultaneous quantification of two important naphthalene metabolites, 1-naphthol and 2-naphthol, in human urine. Except an enzymatic hydrolysis no further sample pre-treatment is necessary. The metabolites are stripped from urinary matrix by on-line extraction on a restricted access material pre-column (RAM RP-8), transferred in backflush mode onto a silica-based CN-(cyano)phase column for further purification from interfering substances. By another successive column switching step both analytes are transferred with a minimum of overlapping interferences onto a C12 bonded reversed phase column with trimethylsilyl endcapping where the final separation is carried out. The entire arrangement is software controlled. Eluting analytes are quantified by fluorescence detection (227/430 nm) after an external calibration. Within a total run time of 40 min we can selectively quantify both naphthols with detection limits in the lower ppb range (1.5 and 0.5 microg/l for 1- and 2-naphthol, respectively) with excellent reliability (ensured by precision, accuracy, matrix-independency and FIOH quality assurance program participation). First results on a collective of 53 occupationally non exposed subjects showed mean levels of 11.0 microg/l (1-naphthol) and 12.9 microg/l (2-naphthol). Among smokers (n=21) a significantly elevated mean level of urinary naphthols was determined (1-naphthol: 19.2 microg/l and 2-naphthol: 23.7 microg/l) in comparison to non smokers (n=32; 1-naphthol: 5.6 microg/l, 2-naphthol: 5.6 microg/l).

  18. Plasmodium species differentiation by non-expert on-line volunteers for remote malaria field diagnosis.

    Science.gov (United States)

    Ortiz-Ruiz, Alejandra; Postigo, María; Gil-Casanova, Sara; Cuadrado, Daniel; Bautista, José M; Rubio, José Miguel; Luengo-Oroz, Miguel; Linares, María

    2018-01-30

    Routine field diagnosis of malaria is a considerable challenge in rural and low resources endemic areas mainly due to lack of personnel, training and sample processing capacity. In addition, differential diagnosis of Plasmodium species has a high level of misdiagnosis. Real time remote microscopical diagnosis through on-line crowdsourcing platforms could be converted into an agile network to support diagnosis-based treatment and malaria control in low resources areas. This study explores whether accurate Plasmodium species identification-a critical step during the diagnosis protocol in order to choose the appropriate medication-is possible through the information provided by non-trained on-line volunteers. 88 volunteers have performed a series of questionnaires over 110 images to differentiate species (Plasmodium falciparum, Plasmodium ovale, Plasmodium vivax, Plasmodium malariae, Plasmodium knowlesi) and parasite staging from thin blood smear images digitalized with a smartphone camera adapted to the ocular of a conventional light microscope. Visual cues evaluated in the surveys include texture and colour, parasite shape and red blood size. On-line volunteers are able to discriminate Plasmodium species (P. falciparum, P. malariae, P. vivax, P. ovale, P. knowlesi) and stages in thin-blood smears according to visual cues observed on digitalized images of parasitized red blood cells. Friendly textual descriptions of the visual cues and specialized malaria terminology is key for volunteers learning and efficiency. On-line volunteers with short-training are able to differentiate malaria parasite species and parasite stages from digitalized thin smears based on simple visual cues (shape, size, texture and colour). While the accuracy of a single on-line expert is far from perfect, a single parasite classification obtained by combining the opinions of multiple on-line volunteers over the same smear, could improve accuracy and reliability of Plasmodium species

  19. On-line maintenance PSA support at NPP Krsko

    International Nuclear Information System (INIS)

    Prosen, R.; Vrbanic, I.; Kastelan, M.

    2000-01-01

    In 1997 Krsko NPP initiated the on-line maintenance (OLM) practice. On-line maintenance constitutes of corrective activities, preventive activities, surveillance activities, tests and inspections, as well as calibrations and modifications, taking place during the normal power operations. The on-line maintenance is a multidisciplinary process consisting of activity specification, planning, and preparation and performing of the OLM activity of interest. The primary role of the PSA group is to assess from the r isk perspective , using the plant-specific NEK PSA model, system unavailability and the impact to the plant operational risk. The intent is to support planning of the on-line maintenance activities from the risk perspective. The risk evaluation of the OLM activities is based on the probability of core damage evaluation for the defined discrete plant configuration states, determined by the OLM activities. Within this application, the optimized, plant-specific PSA model is used on Risk Spectrum platform. To perform the risk assessment of the on-line maintenance activities, first the systems to be affected are defined based on the planned OLM activities. The next important step is the assessment of the planned work schedule. To define the final schedule, the co-ordination and optimizing the planned OLM activities needs activation of all participating departments, supported also from PSA group. The P3 (i.e. Primavera) planning tool system windows are defined for different systems and groups of systems, and the activities are sorted in particular weeks according to these windows. (author)

  20. OLDASS: On-line data acquisition system at SF cyclotron

    International Nuclear Information System (INIS)

    Omata, Kazuo; Yasue, Masaharu; Hamagaki, Hideki

    1982-01-01

    The on-line data acquisition system in the Institute for Nuclear Study, the University of Tokyo, is composed of 2 systems of Fujitsu mini-computer PFU-400 for data processing at the high energy synchrotron and one system of that computer for low energy cyclotron as terminals, the host computer being M 180 II AD of the same company. This system has been developed to have the features of being the on-line system capable of following the improvement of host computer performance, being capable of developing the on-line programmes of other experimenting groups in parallel with batch jobs or the operation of the on-line system, and capable of developing programmes using FORTRAN. The result of about 220 KB/s was obtained for the data transfer rate between the programmes of the host computer and terminals, and this fulfilled the aimed performance. The terminal system on the low energy side is provided with an ADC interface and a display interface specified particularly in addition to the miniature computer PFU400 and standard I/O devices of the manufacture. The accumulating type graphic display of the I/O devices can be switched to be connected to the host computer, and immediately displays the results transferred to the host computer and analyzed. Hard copy is also available. The above hardware and software are explained. The on-line system insures 80 K bytes of the total memory of 224 K bytes for data area. (Wakatsuki, Y.)

  1. Sport Management Taught On-Line: A Discussion

    Directory of Open Access Journals (Sweden)

    William F. Stier Jr

    2009-01-01

    Full Text Available An introduction to the world of on-line courses (distance education/learning is presented. In addition, the world of on-line learning, as it pertains to sport management, is examined within the framework of (a pedagogy, (b finances,(c assessment, and (d choosing to transition from the traditional classroom to on-line learning. Pertinent points relative to each of the four categories are presented from the literature. In an effort to stimulate thought and discussion to the subject of on-line learning for sport management programs/courses the authors provide their reactions to the literature points by presenting their comments/reactions from a sport management perspective. Sport management professors and administrators are encouraged to critically examine the feasibility of such on-line courses (distance education/learning within their own curricula while maintaining an appropriate framework revolving around sound theoretical instructional strategies, methods as well as appropriate use of instructional tools, including but not limited to, computersand the WWW.

  2. Processes for pretreating lignocellulosic biomass: A review

    Energy Technology Data Exchange (ETDEWEB)

    McMillan, J.D.

    1992-11-01

    This paper reviews existing and proposed pretreatment processes for biomass. The focus is on the mechanisms by which the various pretreatments act and the influence of biomass structure and composition on the efficacy of particular pretreatment techniques. This analysis is used to identify pretreatment technologies and issues that warrant further research.

  3. On-line monitoring of monoclonal antibody formation in high density perfusion culture using FIA.

    Science.gov (United States)

    Fenge, C; Fraune, E; Freitag, R; Scheper, T; Schügerl, K

    1991-05-01

    An automated flow injection system for on-line analysis of proteins in real fermentation fluids was developed by combining the principles of stopped-flow, merging zones flow injection analysis (FIA) with antigen-antibody reactions. IgG in the sample reacted with its corresponding antibody (a-IgG) in the reagent solution. Formation of insoluble immunocomplexes resulted in an increase of the turbidity which was determined photometrically. This system was used to monitor monoclonal antibody production in high cell density perfusion culture of hybridoma cells. Perfusion was performed with a newly developed static filtration unit equipped with hydrophilic microporous tubular membranes. Different sampling devices were tested to obtain a cell-free sample stream for on-line product analysis of high molecular weight (e.g., monoclonal antibodies) and low molecular weight (e.g., glucose, lactate) medium components. In fermentation fluids a good correlation (coefficient: 0.996) between the FIA method and an ELISA test was demonstrated. In a high density perfusion cultivation process mAb formation was successfully monitored on-line over a period of 400 h using a reliable sampling system. Glucose and lactate were measured over the same period of time using a commercially available automatic analyser based on immobilized enzyme technology.

  4. Initiating Events Modeling for On-Line Risk Monitoring Application

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.

    1998-01-01

    In order to make on-line risk monitoring application of Probabilistic Risk Assessment more complete and realistic, a special attention need to be dedicated to initiating events modeling. Two different issues are of special importance: one is how to model initiating events frequency according to current plant configuration (equipment alignment and out of service status) and operating condition (weather and various activities), and the second is how to preserve dependencies between initiating events model and rest of PRA model. First, the paper will discuss how initiating events can be treated in on-line risk monitoring application. Second, practical example of initiating events modeling in EPRI's Equipment Out of Service on-line monitoring tool will be presented. Gains from application and possible improvements will be discussed in conclusion. (author)

  5. Strengthening weak ties through on-line gaming

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana Virginia; Kirchner, Kathrin

    On-line gaming became widespread in the last couple of years. The aim of the research presented in the paper is to figure out to what extent does game playing helps to strengthen weak ties and what additional factors influence this process. The approach is rather exploratory – some factors...... are grounded in theory, some are new. These factors are age, gender, place of origin, number of their Facebook connections (friends in Facebook terminology), the amount of time they are on Facebook, the amount of time they keep the Facebook site open, the amount of time they play on-line games, and the reasons...... for starting to play on-line games. Regarding the latter, we chose to focus only on escapist reasons....

  6. Thermographic Sensing For On-Line Industrial Control

    Science.gov (United States)

    Holmsten, Dag

    1986-10-01

    It is today's emergence of thermoelectrically cooled, highly accurate infrared linescanners and imaging systems that has definitely made on-line Infraread Thermography (IRT) possible. Specifically designed for continuous use, these scanners are equipped with dedicated software capable of monitoring and controlling highly complex thermodynamic situations. This paper will outline some possible implications of using IRT on-line by describing some uses of this technology in the steel-making (hot rolling) and automotive industries (machine-vision). A warning is also expressed that IRT technology not originally designed for automated applications e.g. high resolution, imaging systems, should not be directly applied to an on-line measurement situation without having its measurement resolution, accuracy and especially its repeatability, reliably proven. Some suitable testing procedures are briefly outlined at the end of the paper.

  7. An on-line monitoring system for navigation equipment

    Science.gov (United States)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  8. On-line calculation of 3-D power distribution

    International Nuclear Information System (INIS)

    Park, Y. H.; In, W. K.; Park, J. R.; Lee, C. C.; Auh, G. S.

    1996-01-01

    The 3-D power distribution synthesis scheme was implemented in Totally Integrated Core Operation Monitoring System (TICOMS), which is under development as the next generation core monitoring system. The on-line 3-D core power distribution obtained from the measured fixed incore detector readings is used to construct the hot pin power as well as the core average axial power distribution. The core average axial power distribution and the hot pin power of TICOMS were compared with those of the current digital on-line core monitoring system, COLSS, which construct the core average axial power distribution and the pseudo hot pin power. The comparison shows that TICOMS results in the slightly more accurate core average axial power distribution and the less conservative hot pin power. Therefore, these results increased the core operating margins. In addition, the on-line 3-D power distribution is expected to be very useful for the core operation in the future

  9. UNISOR on-line nuclear orientation facility (UNISOR/NOF)

    International Nuclear Information System (INIS)

    Girit, I.C.; Alton, G.D.; Bingham, C.R.; Carter, H.K.; Simpson, M.L.; Cole, J.D.; Croft, W.L.; Hamilton, J.H.; Jones, E.F.; Gore, P.M.; Kormicki, J.; Xie, H.; Kern, B.D.; Krane, K.S.; Xu, Y.S.; Mantica, P.F. Jr.; Zimmermann, B.E.; Nettles, W.G.; Zganjar, E.F.; Kortelahti, M.O.; Newbolt, W.B.

    1988-01-01

    The UNISOR on-line nuclear orientation facility (UNISOR/NOF) consists of a 3 He- 4 He dilution refrigerator on line to the isotope separator. Nuclei are implanted directly into a target foil which is soldered to the bottom accessed cold finger of the refrigerator. A 1.5 T superconducting magnet polarizes the ferromagnetic target foils and determines the axis of symmetry. Up to eight gamma detectors can be positioned around the refrigerator, each 9 cm from the target. A unique feature of this system is that the k=4 term in the directional distribution function can be directly and unambigously deduced so that a single solution for the mixing ratio can be found. The first on-line experiment at this facility reported here was a study of the decay of the 191 Hg and 193 Hg isotopes. (orig.)

  10. On-line SPE-UHPLC method using fused core columns for extraction and separation of nine illegal dyes in chilli-containing spices.

    Science.gov (United States)

    Khalikova, Maria A; Satínský, Dalibor; Smidrkalová, Tereza; Solich, Petr

    2014-12-01

    The presented work describes the development of a simple, fast and effective on-line SPE-UHPLC-UV/vis method using fused core particle columns for extraction, separation and quantitative analysis of the nine illegal dyes, most frequently found in chilli-containing spices. The red dyes Sudan I-IV, Sudan Red 7B, Sudan Red G, Sudan Orange G, Para Red, and Methyl Red were separated and analyzed in less than 9 min without labor-consuming pretreatment procedure. The chromatographic separation was performed on Ascentis Express RP-Amide column with gradient elution using mixture of acetonitrile and water, as a mobile phase at a flow rate of 1.0 mL min(-1) and 55°C of temperature. As SPE sorbent for cleanup and pre-concentration of illegal dyes short guard fused core column Ascentis Express F5 was used. The applicability of proposed method was proven for three different chilli-containing commercial samples. Recoveries for all compounds were between 90% and 108% and relative standard deviation ranged from 1% to 4% for within- and from 2% to 6% for between-day. Limits of detection showed lower values than required by European Union regulations and were in the range of 3.3-10.3 µg L(-1) for standard solutions, 5.6-235.6 µg kg(-1) for chilli-containing spices. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. On-line monitoring of glucose and/or lactate in a fermentation process using an expanded micro-bed flow injection analyser.

    Science.gov (United States)

    Nandakumar, M P; Lali, A M; Mattiasson, B

    1999-01-01

    A novel flow injection biosensor system for monitoring fermentation processes has been developed using an expanded micro bed as the enzyme reactor. An expanded bed reactor is capable of handling a mobile phase containing suspended matter like cells and cell debris. Thus, while the analyte is free to interact with the adsorbent, the suspended particulate matter passes through unhindered. With the use of a scaled down expanded bed in the flow injection analysis (FIA) system, it was possible to analyse samples directly from a fermentor without the pretreatment otherwise required to extract the analyte or remove the suspended cells. This technique, therefore, provides a means to determine the true concentrations of the metabolites in a fermentor, with more ease than possible with other techniques. Glucose oxidase immobilised on STREAMLINE was used to measure glucose concentration in a suspension of dead yeast cells. There was no interference from the cell particles even at high cell densities such as 15 gm dry weight per litre. The assay time was about 6 min. Accuracy and reproducibility of the system was found to be good. In another scheme, lactate oxidase was covalently coupled to STREAMLINE for expanded bed operation. With the on-line expanded micro bed FIA it was possible to follow the fermentation with Lactobacillus casei.

  12. Making the most of on-line recruiting.

    Science.gov (United States)

    Cappelli, P

    2001-03-01

    Ninety percent of large U.S. companies are already recruiting via the Internet. By simply logging on to the Web, company recruiters can locate vast numbers of qualified candidates for jobs at every level, screen them in minutes, and contact the most promising ones immediately. The payoffs can be enormous: it costs substantially less to hire someone on-line, and the time saved is equally great. In this article, Peter Cappelli examines some of the emerging service providers and technologies--matchmakers, job boards, hiring management systems software, and applicant-screening mechanisms that test skills and record interests. He also looks at some of the strategies companies are adopting as they enter on-line labor markets. Recruiting needs to be refashioned to resemble marketing, he stresses. Accordingly, smart companies are designing Web pages, and even product ads, with potential recruits in mind. They're giving line managers authority to hire so that candidates in cyberspace aren't lost. They're building internal on-line job networks to retain talent. Integrating recruiting efforts with overall marketing campaigns, especially through coordination and identification with the company's brand, is the most important thing companies can do to ensure success in on-line hiring. Along the way, Cappelli sounds two cautionary notes. First, a human touch, not electronic contact, is vital in the last steps of a successful hiring process. Second, companies must make sure that on-line testing and hiring criteria do not discriminate against women, disabled people, workers over 40, or members of minority groups. When competition for talent is fierce, companies that master the art and science of on-line recruiting will be the ones that attract and keep the best people.

  13. The User-friendly On-Line Diffusion Chamber

    CERN Document Server

    Aviles Acosta, Jaime

    2015-01-01

    The On-Line Diffusion Chamber is a stand-alone apparatus built to carry out short-live radiotracer diffusion studies. The availability of the on-demand production of isotopes in the ISOLDE facility, and the design of the apparatus to streamline the implantation process, annealing treatment, ion gun ablation with a tape transport system, and radiation intensity measurement with a Ge gamma detector all in the same apparatus, gives the On-Line Diffusion Chamber a unique ability to studies with short-lived radioisotopes or isomer states that are not possible in any other facility in the world.

  14. The rationalization of desulfurization by on-line analysis

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Y; Kohmura, S; Taketomi, H; Matsumura, S; Sasaki, Y

    1986-01-01

    Nippon Kokan uses the Takahax and Sulfiban processes for the desulfurization of coke oven gas. The authors outline the Sulfiban Process and describe a recently developed system for the on-line determination of H/sub 2/S in coke oven gas, and of CO/sub 2/ and monoethanolamine (MEA) in the wash oil. This new on-line analysis system has proved effective in rationalizing the Sulfiban Process via lower MEA production costs and decreased power consumption. The introduction of a computerized control system is now being studied. 7 figs., 4 tabs.

  15. 5th Computer Science On-line Conference

    CERN Document Server

    Senkerik, Roman; Oplatkova, Zuzana; Silhavy, Petr; Prokopova, Zdenka

    2016-01-01

    This volume is based on the research papers presented in the 5th Computer Science On-line Conference. The volume Artificial Intelligence Perspectives in Intelligent Systems presents modern trends and methods to real-world problems, and in particular, exploratory research that describes novel approaches in the field of artificial intelligence. New algorithms in a variety of fields are also presented. The Computer Science On-line Conference (CSOC 2016) is intended to provide an international forum for discussions on the latest research results in all areas related to Computer Science. The addressed topics are the theoretical aspects and applications of Computer Science, Artificial Intelligences, Cybernetics, Automation Control Theory and Software Engineering.

  16. Comparison of Current On-line Payment Technologies

    OpenAIRE

    Mandadi, Ravi

    2006-01-01

    The purpose of this thesis work was to make a survey of current on-line payment technologies and find out which are they and how do they work? Compare and analyze them from a security point of view, as well as a usability point of view. What is good? What is bad? What is lacking? To achieve this purpose, an overview of the current on-line payment technologies was acquired through academic books and papers, Internet sites, magazines. Basic cryptographic and security related techniques were stu...

  17. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  18. On-Line Generation of 3D-Waves

    DEFF Research Database (Denmark)

    Frigaard, Peter

    1992-01-01

    The paper describes the technique of filtering white noise for on-line generation of 3D-waves on a small computer in the laboratory. The wave generation package is implemented and tested in the 3D-wave basin at the University of Aalborg.......The paper describes the technique of filtering white noise for on-line generation of 3D-waves on a small computer in the laboratory. The wave generation package is implemented and tested in the 3D-wave basin at the University of Aalborg....

  19. High rate spectroscopy for on-line nuclear coal analyzer (Nucoalyzer)

    International Nuclear Information System (INIS)

    McQuaid, J.H.; Brown, D.R.; Gozani, T.; Bozorgmanesh, H.

    1980-01-01

    A high count rate, time-variant Ge(Li) spectrometer has been developed for on-line coal analysis. The analyzer is being fabricated for use in a power generating station. Prompt neutron activation of coal samples is the basis of analysis, with 252 Cf as the source for irradiation. The spectroscopy system allows counting rates up to 150 k counts per second without significant loss in energy resolution or peak shape. The high data throughput allows the coal analyzer to be used for on-line process control. The coal analyzer will be discussed, with emphasis on the high-rate signal processing system. Results of analysis of coal samples will be presented

  20. Inexpensive on-line alcohol sensor for fermentation monitoring and control

    Energy Technology Data Exchange (ETDEWEB)

    Birch, S W; Turner, A P.F.; Ashby, R E

    1987-01-01

    An inorganic electrochemical fuel cell sensor was interfaced to a microcomputer and used to measure on-line the alcohol concentration in the off-gas of a fermentor. A calibration curve was obtained for methanol (linear range 0-9 g/l) and ethanol (linear range 0-6 g/l) to relate the alcohol concentration in the fermentor liquid with that in the off-gas. The consumption of methanol in a batch fermentation of the methylotroph Ps.BB1 was monitored (sampling frequency of 5 minutes) and compared with samples taken for off-line analysis by GLC. On-line control of the methanol concentration in a fed-batch fermentation was achieved by proportional and integral control. 24 references.

  1. On-Line Ion Exchange Liquid Chromatography as a Process Analytical Technology for Monoclonal Antibody Characterization in Continuous Bioprocessing.

    Science.gov (United States)

    Patel, Bhumit A; Pinto, Nuno D S; Gospodarek, Adrian; Kilgore, Bruce; Goswami, Kudrat; Napoli, William N; Desai, Jayesh; Heo, Jun H; Panzera, Dominick; Pollard, David; Richardson, Daisy; Brower, Mark; Richardson, Douglas D

    2017-11-07

    Combining process analytical technology (PAT) with continuous production provides a powerful tool to observe and control monoclonal antibody (mAb) fermentation and purification processes. This work demonstrates on-line liquid chromatography (on-line LC) as a PAT tool for monitoring a continuous biologics process and forced degradation studies. Specifically, this work focused on ion exchange chromatography (IEX), which is a critical separation technique to detect charge variants. Product-related impurities, including charge variants, that impact function are classified as critical quality attributes (CQAs). First, we confirmed no significant differences were observed in the charge heterogeneity profile of a mAb through both at-line and on-line sampling and that the on-line method has the ability to rapidly detect changes in protein quality over time. The robustness and versatility of the PAT methods were tested by sampling from two purification locations in a continuous mAb process. The PAT IEX methods used with on-line LC were a weak cation exchange (WCX) separation and a newly developed shorter strong cation exchange (SCX) assay. Both methods provided similar results with the distribution of percent acidic, main, and basic species remaining unchanged over a 2 week period. Second, a forced degradation study showed an increase in acidic species and a decrease in basic species when sampled on-line over 7 days. These applications further strengthen the use of on-line LC to monitor CQAs of a mAb continuously with various PAT IEX analytical methods. Implementation of on-line IEX will enable faster decision making during process development and could potentially be applied to control in biomanufacturing.

  2. Engaging Students On-Line:Does Gender Matter in Adoption of Learning Material Design?

    Directory of Open Access Journals (Sweden)

    Norziani Dahalan

    2013-12-01

    Full Text Available Education is reforming with the birth of the internet. Learning is not solely based on classroom basis but also through on-line. The revolution of Internet has transformed teaching via face-to-face into virtual teaching. The expansion of teaching deliveries suggests that we need interactive mechanism to accommodate course material for on-line students. However, creating on-line materials requires the conception of on-line instructional design. A suitable online material design will allow learners to engage with learning. Learners will have opportunities to develop their own understanding. In addition, suitable learning material will strengthen learner’s knowledge construction from their short-term memory to long-term memory. The purpose of this paper is to discover the learning material design approach based on gender by evaluating lecturer’s adoption of online material design using Keller’s ARCS model. The sample consisting of 30 lecturers from distance education learning reveals that gender differs in their adoption of learning material design specifically on getting attention of the student. The result also shows that relevance and satisfaction contribute to gender differences in learning material adoption. Limitations of the study and practical implications of these findings discussed.

  3. On-line sodium and cover as purity monitors gas operating tools at EBR-II

    International Nuclear Information System (INIS)

    Smith, C.R.F.; Richardson, W.J.; Holmes, J.T.

    1976-01-01

    Plugging temperature indicators, electrochemical oxygen meters and hydrogen diffusion meters are the on-line sodium purity monitors now in use at EBR-II. On-line gas chromatographs are used to monitor helium, hydrogen, oxygen and nitrogen impurities in the argon cover gases. Monitors for tritium-in-sodium and for hydrocarbons-in-cover gas have been developed and are scheduled for installation in the near future. An important advantage of on-line monitors over the conventional grab-sampling techniques is the speed of response to changing reactor conditions. This helps us to identify the source of the impurity, whether the cause may be transient or constant, and take corrective action as necessary. The oxygen meter is calibrated monthly against oxygen in sodium determined by the vanadium wire equilibration method. The other instruments either do not require calibration or are self-calibrating. The ranges, sensitivity and response times of all of the on-line purity monitors has proven satisfactory under EBR-II operating conditions

  4. TWRS tank waste pretreatment process development hot test siting report

    International Nuclear Information System (INIS)

    Howden, G.F.; Banning, D.L.; Dodd, D.A.; Smith, D.A.; Stevens, P.F.; Hansen, R.I.; Reynolds, B.A.

    1995-02-01

    This report is the sixth in a series that have assessed the hot testing requirements for TWRS pretreatment process development and identified the hot testing support requirements. This report, based on the previous work, identifies specific hot test work packages, matches those packages to specific hot cell facilities, and provides recommendations of specific facilities to be employed for the pretreatment hot test work. Also identified are serious limitations in the tank waste sample retrieval and handling infrastructure. Recommendations are provided for staged development of 500 mL, 3 L, 25 L and 4000 L sample recovery systems and specific actions to provide those capabilities

  5. Analysis of particulate polycyclic aromatic hydrocarbons by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Science.gov (United States)

    Shimmo, Masahiko; Adler, Heidi; Hyötyläinen, Tuulia; Hartonen, Kari; Kulmala, Markku; Riekkola, Marja-Liisa

    An on-line supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS) method was developed for the analysis of the particulate polycyclic aromatic hydrocarbons (PAHs). The limits of detection of the system for the quantification standards were in the range of 0.25-0.57 ng, while the limits of determinations for filter samples varied from 0.02 to 0.04 ng m -3 (24 h sampling). The linearity was excellent from 5 to 300 ng ( R2>0.967). The analysis could be carried out in a closed system without tedious manual sample pretreatment and with no risk of errors by contamination or loss of the analytes. The results of the SFE-LC-GC-MS method were comparable with those for Soxhlet and shake-flask extractions with GC-MS. The new method was applied to the analysis of PAHs collected by high-volume filter in the Helsinki area to study the seasonal trend of the concentrations. The individual PAH concentrations varied from 0.015 to more than 1 ng m -3, while total PAH concentrations varied from 0.81 to 5.68 ng m -3. The concentrations were generally higher in winter than in summer. The mass percentage of the total PAHs in total suspended particulates ranged from 2.85×10 -3% in July to 15.0×10 -3% in December. Increased emissions in winter, meteorological conditions, and more serious artefacts during the sampling in summer season may explain the concentration profiles.

  6. Modified thermogravimetric apparatus to measure magnetic susceptibility on-line during annealing of metastable ferromagnetic materials

    International Nuclear Information System (INIS)

    Luciani, G.; Constantini, A.; Branda, F.; Ausanio, G.; Hison, C.; Iannotti, V.; Luponio, C.; Lanotte, L.

    2004-01-01

    The insertion of proper coils to generate a magnetic field, with controlled gradient, in a standard thermogravimetric apparatus is shown to be a valid solution to measure on-line, upon heat treatment, the magnetic susceptibility in ribbon shaped samples of a metastable ferromagnetic material. The method is very useful to individuate the annealing conditions that optimise soft or hard magnetic properties without using separate apparatuses for heat treatment, control of the structural phase transition and characterization of magnetic susceptibility

  7. On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection Pré-concentração em linha para a determinação simultânea de ácidos carboxílicos de baixo peso molecular e ânions inorgânicos em amostras de rios da Amazônia empregando cromatografia de íons com detecção por condutividade elétrica

    Directory of Open Access Journals (Sweden)

    Cristiane Azevedo Tumang

    2009-01-01

    Full Text Available An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.. The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate, without extensive sample pretreatment and with an analysis time of only 24 minutes.A metodologia analítica foi desenvolvida empregando coluna pré-concentradora AC15 em linha na cromatografia iônica na determinação simultânea de ânions orgânicos e inorgânicos, com uso de coluna de guarda AG15 e analítica AS15, 250 x 4 mm i.d. (Dionex Corp.. O gradiente de concentração do eluente

  8. Microfluidic electrochemical sensor for on-line monitoring of aerosol oxidative activity.

    Science.gov (United States)

    Sameenoi, Yupaporn; Koehler, Kirsten; Shapiro, Jeff; Boonsong, Kanokporn; Sun, Yele; Collett, Jeffrey; Volckens, John; Henry, Charles S

    2012-06-27

    Particulate matter (PM) air pollution has a significant impact on human morbidity and mortality; however, the mechanisms of PM-induced toxicity are poorly defined. A leading hypothesis states that airborne PM induces harm by generating reactive oxygen species in and around human tissues, leading to oxidative stress. We report here a system employing a microfluidic electrochemical sensor coupled directly to a particle-into-liquid sampler (PILS) system to measure aerosol oxidative activity in an on-line format. The oxidative activity measurement is based on the dithiothreitol (DTT) assay, where, after being oxidized by PM, the remaining reduced DTT is analyzed by the microfluidic sensor. The sensor consists of an array of working, reference, and auxiliary electrodes fabricated in a poly(dimethylsiloxane)-based microfluidic device. Cobalt(II) phthalocyanine-modified carbon paste was used as the working electrode material, allowing selective detection of reduced DTT. The electrochemical sensor was validated off-line against the traditional DTT assay using filter samples taken from urban environments and biomass burning events. After off-line characterization, the sensor was coupled to a PILS to enable on-line sampling/analysis of aerosol oxidative activity. Urban dust and industrial incinerator ash samples were aerosolized in an aerosol chamber and analyzed for their oxidative activity. The on-line sensor reported DTT consumption rates (oxidative activity) in good correlation with aerosol concentration (R(2) from 0.86 to 0.97) with a time resolution of approximately 3 min.

  9. Integrated sensor array for on-line monitoring micro bioreactors

    NARCIS (Netherlands)

    Krommenhoek, E.E.

    2007-01-01

    The “Fed��?batch on a chip��?��?project, which was carried out in close cooperation with the Technical University of Delft, aims to miniaturize and parallelize micro bioreactors suitable for on-line screening of micro-organisms. This thesis describes an electrochemical sensor array which has been

  10. On-Line Pesticide Training with Narrated Powerpoint Presentations

    Science.gov (United States)

    Johnson, Steven B.

    2015-01-01

    UMaine Cooperative Extension is the primary educational delivery organization for pesticide recertification credits in Maine. Shrinking budgets and staff numbers are making traditional face-to-face delivery increasingly difficult to maintain. To address this issue, on-line pesticide applicator recertification training credits were developed. The…

  11. Personality Interactions and Scaffolding in On-Line Discussions

    Science.gov (United States)

    Nussbaum, E. Michael; Hartley, Kendall; Sinatra, Gale M.; Reynolds, Ralph E.; Bendixen, Lisa D.

    2004-01-01

    The potential of on-line discussions to prompt greater reflection of course material is often stymied by a tendency of students to agree with one another rather than to formulate counter-arguments. This article describes an experiment using note starters and elaborated cases to encourage counter-argumentation and examines interactions with…

  12. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.; Hubert, F.; Llabador, Y.; Mauhourat, M.B.; Bimbot, R.; Gardes, D.; Rivet, M.F.

    1981-01-01

    The working conditions of a new on-line electrostatic collection system are presented. The main characteristics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given. (orig.)

  13. Specialization processes in on-line unsupervised learning

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Reents, G.; Schlösser, E.

    1998-01-01

    From the recent analysis of supervised learning by on-line gradient descent in multilayered neural networks it is known that the necessary process of student specialization can be delayed significantly. We demonstrate that this phenomenon also occurs in various models of unsupervised learning. A

  14. A simulation of the SDC on-line processing farm

    International Nuclear Information System (INIS)

    Wang, C.; Chen, Y.; Dorenbosch, J.; Lee, J.; Sayle, R.

    1993-10-01

    In the Solenoidal Detector Collaboration (SDC) data acquisition system (DAQ), an enormous amount of data flows into a processor farm for extraction of interesting physics events. To design an efficient on-line filter, the operations in the farm must be carefully modeled. The authors present a simulation model developed at the Superconducting Super Collider Laboratory which efficiently allocates physics events to the farm

  15. On-Line Synthesis and Analysis by Mass Spectrometry

    Science.gov (United States)

    Bain, Ryan M.; Pulliam, Christopher J.; Raab, Shannon A.; Cooks, R. Graham

    2015-01-01

    In this laboratory experiment, students learn how to use ESI to accelerate chemical synthesis and to couple it with on-line mass spectrometry for structural analysis. The Hantzsch synthesis of symmetric 1,4-dihydropyridines is a classic example of a one-pot reaction in which multiple intermediates can serve to indicate the progress of the reaction…

  16. An optimal algorithm for preemptive on-line scheduling

    NARCIS (Netherlands)

    Chen, B.; Vliet, van A.; Woeginger, G.J.

    1995-01-01

    We investigate the problem of on-line scheduling jobs on m identical parallel machines where preemption is allowed. The goal is to minimize the makespan. We derive an approximation algorithm with worst-case guarantee mm/(mm - (m - 1)m) for every m 2, which increasingly tends to e/(e - 1) ˜ 1.58 as m

  17. Comparison between constant methanol feed and on-line ...

    African Journals Online (AJOL)

    Two methanol feeding methods, namely constant methanol feed and on-line monitoring feed control by methanol sensor were investigated to improve the production of recombinant human growth hormone (rhGH) in high cell density cultivation of Pichia pastoris KM71 in 2 L bioreactor. The yeast utilized glycerol as a carbon ...

  18. Children's On-Line Processing of Scrambling in Japanese

    Science.gov (United States)

    Suzuki, Takaaki

    2013-01-01

    This study investigates the on-line processing of scrambled sentences in Japanese by preschool children and adults using a combination of self-paced listening and speeded picture selection tasks. The effects of a filler-gap dependency, reversibility, and case markers were examined. The results show that both children and adults had difficulty in…

  19. AAEC INIS - a large, new, on-line information source

    International Nuclear Information System (INIS)

    Rugg, T.J.; Wong, S.C.

    1984-01-01

    The Australian Atomic Energy Commission's INIS database is available for on-line searching by non-AAEC personnel from all parts of Australia. An introduction to the International Nuclear Information System is followed by information on searching AAEC INIS, AAEC INIS retrieval software and accessing AAEC INIS

  20. ORION-the Omega Remote Interactive On-line System

    CERN Document Server

    Russell, R D; Levratt, B; Lipps, H; Sparrman, P

    1974-01-01

    ORION is a system which permits the manipulation of files, records and characters, remote job submittal and retrieval of output files including the direct loading of remote on-line computers. The system uses the computer hardware of the OMEGA project at CERN and is designed to assist researchers in development and debugging of their programs. (10 refs).

  1. ORION - the OMEGA Remote Interactive On-line System

    CERN Document Server

    Russell, R D; Krieger, M

    1973-01-01

    ORION is a system which permits the manipulation of files, records and characters, remote job submittal and retrieval of output files including the direct loading of remote on-line computers. The system uses the computer hardware of the OMEGA project at CERN, and is designed to assist researchers in development and debugging of their programs.

  2. Booth Library On-Line Circulation System (BLOC

    Directory of Open Access Journals (Sweden)

    Paladugu V. Rao

    1971-06-01

    Full Text Available An on-line circulation system developed at a relatively small university library demonstrates that academic libraries with limited funds can develop automated systems utilizing parent institution's computer facilities in a time-sharing mode. In operation since September 1968, using an IBM 360/50 computer and associated peripheral equipment, it provides control over all stack books.

  3. On-line learning from clustered input examples

    NARCIS (Netherlands)

    Riegler, Peter; Biehl, Michael; Solla, Sara A.; Marangi, Carmela; Marinaro, Maria; Tagliaferri, Roberto

    1996-01-01

    We analyse on-line learning of a linearly separable rule with a simple perceptron. Example inputs are taken from two overlapping clusters of data and the rule is defined through a teacher vector which is in general not aligned with the connection line of the cluster centers. We find that the Hebb

  4. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.

    1981-06-01

    The working conditions of a new on-line electrostatic collection system are presented. The main charactersitics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given

  5. Summary remarks and prospects for on-line nuclear orientation

    International Nuclear Information System (INIS)

    Krane, K.S.; Hamilton, J.H.

    1984-01-01

    This paper reviews the use of on-line nuclear orientations as a method for determining hyperfine structure. Historical developments and future prospects for the technique are presented. The role that this technique can play in nuclear spectroscopy and the study of nuclei far from the beta stability are outlined

  6. WMI2, the Student's On-Line Symbolic Calculator

    Science.gov (United States)

    Kovacs, Zoltan

    2011-01-01

    Student activities focused on discovering mathematics play an important role in the teaching and learning process. WebMathematics Interactive (WMI2) was developed to offer a fast and user-friendly on-line web interface to enhance the quality of both theoretical and applied mathematics courses. For the teacher, in the classroom, it provides…

  7. ADAPTIVE CONTEXT PROCESSING IN ON-LINE HANDWRITTEN CHARACTER RECOGNITION

    NARCIS (Netherlands)

    Iwayama, N.; Ishigaki, K.

    2004-01-01

    We propose a new approach to context processing in on-line handwritten character recognition (OLCR). Based on the observation that writers often repeat the strings that they input, we take the approach of adaptive context processing. (ACP). In ACP, the strings input by a writer are automatically

  8. Microcomputers as on-line catalogs in special libraries.

    Science.gov (United States)

    Faust, J B

    1986-01-01

    This article discusses the rationale for the conversion of a card catalog to an on-line system in a special library owning approximately 4000 titles. Equipment, software, and procedures are described. Pros and cons of the use of a microcomputer for such a project, as well as costs and personnel needs, are outlined.

  9. Efficient and secure comparison for on-line auctions

    NARCIS (Netherlands)

    Damgard, Ivan; Geisler, M.; Kroigaard, M.; Pieprzyk, J.; Ghodosi, H.; Dawson, E.

    2007-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption. We also propose a homomorphic encryption scheme that can be used in our protocol and makes it more efficient than previous solutions. Our protocol is well-suited for application in on-line auctions, both with

  10. The on-line asymmetric traveling salesman problem

    NARCIS (Netherlands)

    Ausiello, G.; Bonifaci, V.; Laura, L.

    2008-01-01

    We consider two on-line versions of the asymmetric traveling salesman problem with triangle inequality. For the homing version, in which the salesman is required to return in the city where it started from, we give a -competitive algorithm and prove that this is best possible. For the nomadic

  11. Facing regulatory challenges of on-line hemodiafiltration.

    Science.gov (United States)

    Kümmerle, Wolfgang

    2011-01-01

    On-line hemodiafiltration (on-line HDF) is the result of a vision that triggered multifarious changes in very different areas. Driven by the idea to offer better medical treatment for renal patients, technological innovations were developed and established that also constituted new challenges in the field of regulatory affairs. The existing regulations predominantly addressed the quality and safety of those products needed to perform dialysis treatment which were supplied by industrial manufacturers. However, the complexity of treatment system required for the provision of on-line fluids demanded a holistic approach encompassing all components involved. Hence, focus was placed not only on single products, but much more on their interfacing, and the clinical infrastructure, in particular, had to undergo substantial changes. The overall understanding of the interaction between such factors, quite different in their nature, was crucial to overcome the arising regulatory obstacles. This essay describes the evolution of the on-line HDF procedure from the regulatory point of view. A simplified diagram demonstrates the path taken from the former regulatory understanding to the realization of necessary changes. That achievement was only possible through 'management of preview' and consequent promotion of technical and medical innovations as well as regulatory re-evaluations. Copyright © 2011 S. Karger AG, Basel.

  12. Project development and commercialization of on-line analysis systems

    International Nuclear Information System (INIS)

    Watt, J.S.

    1997-01-01

    A project team first in the Australian Atomic Energy Commission (AAEC) and since 1982 in CSIRO has developed many on-line analysis systems for the mineral and energy industries. The development of these projects has followed a common pattern of laboratory R and D, field trials, commercialisation and technology transfer. This successful pattern is illustrated using examples of the development of systems for the on-line analysis of mineral slurries, for determination of the ash content of coal on conveyors, and for determination of the flow rates of oil, water and gas in pipelines. The first two systems are licensed to Australian companies, Amdel Ltd and Mineral Control Instrumentation Ltd. Both systems are used by industry worldwide, and are the market leaders for radioisotope gauges in their application field. The third system, the multiphase flow meter, was licensed in 1997 to Kvaerner FSSL Ltd of Aberdeen. This meter has even greater potential than the other two systems for economic benefit from its used and for numbers of installations. The on-line analysis systems have been developed to increase the productivity of the Australian mineral and energy industries, and to provide economic benefit to Australia. The economic benefit sought is predominantly improved process control based on use of the instrument, rather than from its sale. Sales of instruments are significant, however, with about A$80 million from the analysis systems and their derivatives since the 1970s. Some of the issues associated with the development of the on-line analysis system are outlined

  13. Tank Focus Area pretreatment activities

    International Nuclear Information System (INIS)

    McGinnis, C.P.; Welch, T.D.; Manke, K.L.

    1997-01-01

    Plans call for the high-level wastes to be retrieved from the tanks and immobilized in a stable waste form suitable for long-term isolation. Chemistry and chemical engineering operations are required to retrieve the wastes, to condition the wastes for subsequent steps, and to reduce the costs of the waste management enterprise. Pretreatment includes those processes between retrieval and immobilization, and includes preparation of suitable feed material for immobilization and separations to partition the waste into streams that yield lower life-cycle costs. Some of the technologies being developed by the Tank Focus Area (TFA) to process these wastes are described. These technologies fall roughly into three areas: (1) solid/liquid separation (SLS), (2) sludge pretreatment, and (3) supernate pretreatment

  14. IOOS Data Portals and Uniform On-line Browse Capabilities

    Science.gov (United States)

    Howard, M.; Currier, R. D.; Kobara, S.; Gayanilo, F.

    2015-12-01

    The Gulf of Mexico Coastal Ocean Observing System Regional Association (GCOOS-RA) is one of eleven Regional Associations organized under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) Program Office. Each of the RAs operate standards-based regional data portals designed to aggregate near real-time and historical observed data and modeled outputs from distributed providers and to offer these and derived products in standardized ways to a diverse set of users. The RA's portals are based on the IOOS Data and Communications Plan which describes the functional elements needed for an interoperable system. One of these elements is called "Uniform On-line Browse" which is an informational service designed primarily to visualize the inventory of a portal. An on-line browse service supports the end user's need to discover what parameters are available, to learn the spatial and temporal extend of the holdings, and to examine the character of the data (e.g, variability, gappiness, etc). These pieces of information help the end user decide if the data are fit for his/her purpose and to construct valid data requests. Note that on-line browse is a distinctly different activity than data analysis because it seeks to yield knowledge about the inventory and not about what the data mean. "Uniform" on-line browse is a service that takes advantage of the standardization of the data portal's data access points. Most portals represent station locations on a map. This is a view of the data inventory but these plots are rarely generated by pulling data through the standards-based services offered to the end users but through methods only available to the portal programmers. This work will present results of Uniform On-line browse tools developed within GCOOS-RA and their applicability to other RA portals.

  15. Mentoring Narratives ON-LINE:Teaching the Principalship

    Directory of Open Access Journals (Sweden)

    Allison I. Griffith

    2002-05-01

    Full Text Available The need to develop new models for preparation of school administrators has been a prominent concern in educational discourse in the last decade. Having been criticized for the inadequate preparation of the school leadership cadre, academic departments responsible for training future school administrators have had to revisit their approaches and to reframe their teaching philosophies to ensure the readiness of their graduates for the challenges and complexities of school leadership. This article reports on the new model of principals' training that has been used in York University's Principals' Qualification Program (PQP from the late 1990s onward. One component of the program brings traditional case methodology into a computer-mediated/on-line environment. The on-line cases are narratives from the everyday lives of the Ontario school administrators who serve as mentors in the on-line environment. Situating our discussion within the context of the rapidly changing educational landscape of Ontario, we focus on the PQP model to explore experientially generated case narratives as one method for teaching and learning the work of the local school administrator. We focus particularly on the teaching and learning embedded in computer-mediated or on-line case narratives used in training teachers for school leadership. We argue that the complexities of school leadership—the social, cultural, relational, ethical and moral context of school leadership—can be taught effectively through the reflective processes of on-line case narratives. We seek to contribute to the ongoing dialogue on the potential of new pedagogies and new technologies to help prepare the competent and responsible leaders for tomorrow's schools.

  16. On-line measurement and control in sustainable mineral processing and energy production

    International Nuclear Information System (INIS)

    Sowerby, B.D.

    2002-01-01

    Sustainable development can be defined as development that 'meets the needs of the present without compromising the ability of future generations to meet their own needs' (WCED, 1987). A sustainable minerals and energy industry will need to achieve a number of related objectives including greater energy efficiency, improved utilisation of ore deposits, improved utilisation of existing plant, improved product quality, reduction of waste material, reduction of pollution levels and improved safety margins. These objectives all relate in varying degrees to the triple bottom line of economic, social and environmental benefits. One critical component in achieving these objectives is to develop and apply improved control systems across the full range of industry applications from mining to processing and utilisation. However process control relies heavily on the availability of suitable on-line process instrumentation to provide the data and feedback necessary for its implementation. There is a lot of truth in the saying 'if you can't measure it you can't control it'. In the past measurement was achieved by manual sampling followed by sample preparation (such as drying, mixing, crushing and dividing) and off-line laboratory analysis. However this procedure is often subject to significant sampling errors and, most importantly, the measurements are too slow for control purposes. By contrast, on-line analysis can provide rapid and accurate measurement in real time thus opening up new possibilities for improved process control. As a result, there has been a rapid increase in the industrial application of on-line analysis instrumentation over the past few decades. The main purpose of this paper is to briefly review some past Australian developments of on-line analysis systems in the mineral and coal industries and to discuss present developments and future trends

  17. Development and validation of a rapid HPLC method for the determination of cefdinir in beagle dog plasma integrated with an automatic on-line solid-phase extraction following protein precipitation in the 96-well plate format.

    Science.gov (United States)

    Li, Ji; Wang, Li; Chen, Zhao; Xie, Rui; Li, You; Hang, Taijun; Fan, Guorong

    2012-05-01

    The high-performance liquid chromatography (HPLC) coupled with on-line solid phase extraction (SPE) and ultraviolet (UV) detection was developed for determining cefdinir in beagle dog plasma. After simple pretreatment for plasma with 6% perchloric acid, a volume of 100 μL upper layer of the plasma sample was injected into the self-made on-line SPE column. The analytes were retained on the trap column (Lichrospher C(18), 4.6 mm × 37 mm, 25 μm), and the biological matrix was washed out with the solvent (20mM KH(2)PO(4) adjusted pH 3.0) at flow rate of 2 mL/min. By rotation of the switching valve, the target analytes could be eluted from trap column to analytical column in the back-flush mode by the mobile phase (methanol-acetonitrile-20mM KH(2)PO(4) adjusted pH 3.0, 11.25:6.75:82, v/v/v) at flow rate of 1.5 mL/min, and then separated on the analytical column (Ultimate XB-C(18), 4.6 mm × 50 mm, 5 μm). The complete cycle of the on-line SPE preconcentration, purification and HPLC separation of the analytes was 4 min. The UV detection was performed at 286 nm. The calibration curves showed excellent linear relationship (R(2)=0.9995) over the concentration range of 0.05-50 μg/mL. The optimized method showed good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This method was successfully applied to quantify cefdinir in beagle dog plasma to support the pre-clinical pharmacokinetic trial. Copyright © 2012. Published by Elsevier B.V.

  18. Optimization of Saccharification Conditions of Lignocellulosic Biomass under Alkaline Pre-Treatment and Enzymatic Hydrolysis

    Directory of Open Access Journals (Sweden)

    Rafał Łukajtis

    2018-04-01

    Full Text Available Pre-treatment is a significant step in the production of second-generation biofuels from waste lignocellulosic materials. Obtaining biofuels as a result of fermentation processes requires appropriate pre-treatment conditions ensuring the highest possible degree of saccharification of the feed material. An influence of the following process parameters were investigated for alkaline pre-treatment of Salix viminalis L.: catalyst concentration (NaOH, temperature, pre-treatment time and granulation. For this purpose, experiments were carried out in accordance to the Box-Behnken design for four factors. In the saccharification process of the pre-treated biomass, cellulolytic enzymes immobilized on diatomaceous earth were used. Based on the obtained results, a mathematical model for the optimal conditions of alkaline pre-treatment prediction is proposed. The optimal conditions of alkaline pre-treatment are established as follows: granulation 0.75 mm, catalyst concentration 7%, pre-treatment time 6 h and temperature 65 °C if the saccharification efficiency and cost analysis are considered. An influence of the optimized pre-treatment on both the chemical composition and structural changes for six various lignocellulosic materials (energetic willow, energetic poplar, beech, triticale, meadow grass, corncobs was investigated. SEM images of raw and pre-treated biomass samples are included in order to follow the changes in the biomass structure during hydrolysis.

  19. Cellulase digestibility of pretreated biomass is limited by cellulose accessibility.

    Science.gov (United States)

    Jeoh, Tina; Ishizawa, Claudia I; Davis, Mark F; Himmel, Michael E; Adney, William S; Johnson, David K

    2007-09-01

    Attempts to correlate the physical and chemical properties of biomass to its susceptibility to enzyme digestion are often inconclusive or contradictory depending on variables such as the type of substrate, the pretreatment conditions and measurement techniques. In this study, we present a direct method for measuring the key factors governing cellulose digestibility in a biomass sample by directly probing cellulase binding and activity using a purified cellobiohydrolase (Cel7A) from Trichoderma reesei. Fluorescence-labeled T. reesei Cel7A was used to assay pretreated corn stover samples and pure cellulosic substrates to identify barriers to accessibility by this important component of cellulase preparations. The results showed cellulose conversion improved when T. reesei Cel7A bound in higher concentrations, indicating that the enzyme had greater access to the substrate. Factors such as the pretreatment severity, drying after pretreatment, and cellulose crystallinity were found to directly impact enzyme accessibility. This study provides direct evidence to support the notion that the best pretreatment schemes for rendering biomass more digestible to cellobiohydrolase enzymes are those that improve access to the cellulose in biomass cell walls, as well as those able to reduce the crystallinity of cell wall cellulose.

  20. Automatic Delineation of On-Line Head-And-Neck Computed Tomography Images: Toward On-Line Adaptive Radiotherapy

    International Nuclear Information System (INIS)

    Zhang Tiezhi; Chi Yuwei; Meldolesi, Elisa; Yan Di

    2007-01-01

    Purpose: To develop and validate a fully automatic region-of-interest (ROI) delineation method for on-line adaptive radiotherapy. Methods and Materials: On-line adaptive radiotherapy requires a robust and automatic image segmentation method to delineate ROIs in on-line volumetric images. We have implemented an atlas-based image segmentation method to automatically delineate ROIs of head-and-neck helical computed tomography images. A total of 32 daily computed tomography images from 7 head-and-neck patients were delineated using this automatic image segmentation method. Manually drawn contours on the daily images were used as references in the evaluation of automatically delineated ROIs. Two methods were used in quantitative validation: (1) the dice similarity coefficient index, which indicates the overlapping ratio between the manually and automatically delineated ROIs; and (2) the distance transformation, which yields the distances between the manually and automatically delineated ROI surfaces. Results: Automatic segmentation showed agreement with manual contouring. For most ROIs, the dice similarity coefficient indexes were approximately 0.8. Similarly, the distance transformation evaluation results showed that the distances between the manually and automatically delineated ROI surfaces were mostly within 3 mm. The distances between two surfaces had a mean of 1 mm and standard deviation of <2 mm in most ROIs. Conclusion: With atlas-based image segmentation, it is feasible to automatically delineate ROIs on the head-and-neck helical computed tomography images in on-line adaptive treatments

  1. Comparative study of sulfite pretreatments for robust enzymatic saccharification of corn cob residue

    Directory of Open Access Journals (Sweden)

    Bu Lingxi

    2012-12-01

    Full Text Available Abstract Background Corn cob residue (CCR is a kind of waste lignocellulosic material with enormous potential for bioethanol production. The moderated sulphite processes were used to enhance the hydrophily of the material by sulfonation and hydrolysis. The composition, FT-IR spectra, and conductometric titrations of the pretreated materials were measured to characterize variations of the CCR in different sulfite pretreated environments. And the objective of this study is to compare the saccharification rate and yield of the samples caused by these variations. Results It was found that the lignin in the CCR (43.2% had reduced to 37.8%, 38.0%, 35.9%, and 35.5% after the sulfite pretreatment in neutral, acidic, alkaline, and ethanol environments, respectively. The sulfite pretreatments enhanced the glucose yield of the CCR. Moreover, the ethanol sulfite sample had the highest glucose yield (81.2%, based on the cellulose in the treated sample among the saccharification samples, which was over 10% higher than that of the raw material (70.6%. More sulfonic groups and weak acid groups were produced during the sulfite pretreatments. Meanwhile, the ethanol sulfite treated sample had the highest sulfonic group (0.103 mmol/g and weak acid groups (1.85 mmol/g in all sulfite treated samples. In FT-IR spectra, the variation of bands at 1168 and 1190 cm-1 confirmed lignin sulfonation during sulfite pretreatment. The disappearance of the band at 1458 cm-1 implied the methoxyl on lignin had been removed during the sulfite pretreatments. Conclusions It can be concluded that the lignin in the CCR can be degraded and sulfonated during the sulfite pretreatments. The pretreatments improve the hydrophility of the samples because of the increase in sulfonic group and weak acid groups, which enhances the glucose yield of the material. The ethanol sulfite pretreatment is the best method for lignin removal and with the highest glucose yield.

  2. On-line, proximate analysis of ground beef directly at a meat grinder outlet.

    Science.gov (United States)

    Isaksson, T; Nilsen, B N; Tøgersen, G; Hammond, R P; Hildrum, K I

    1996-07-01

    The fat, moisture and protein contents of ground beef were determined on-line by a diffuse reflectance near infrared (NIR) spectroscopy instrument at the outlet of a meat grinder. Beef samples in the range of 6.2-21.7% fat, 59.6-72.9% moisture and 18.1-20.7% protein were studied. Calibrations from samples ground with hole diameters of 4, 8, 13 or 19 mm in the grinder plate were validated. In addition, calibrations of combinations of these samples from the different hole diameters were validated. Prediction errors, expressed as root mean square error of cross validation of the beef samples, were 0.73-1.50% for fat, 0.75-1.33% for moisture and 0.23-0.32% for protein, depending on the hole diameter of the grinder plate. Calibrations from samples ground with the smallest hole diameters gave lowest prediction errors. The present prediction error results are only slightly higher compared to reported prediction error results using conventional at- and off-line NIR instruments. It is concluded that the on-line NIR prediction results were acceptable for samples ground with grinder plates of 4, 8 or 13 mm hole diameter.

  3. Novel fungal consortium pretreatment of waste oat straw to enhance economic and efficient biohydrogen production

    Directory of Open Access Journals (Sweden)

    Lirong Zhou

    2016-12-01

    Full Text Available Bio-pretreatment using a fungal consortium to enhance the efficiency of lignocellulosic biohydrogen production was explored.  A fungal consortium comprised of T. viride and P. chrysosporium as microbial inoculum was compared with untreated and single-species-inoculated samples. Fungal bio-pretreatment was carried out at atmospheric conditions with limited external energy input.  The effectiveness of the pretreatment is evaluated according to its lignin removal and digestibility. Enhancement of biohydrogen production is observed through scanning electron microscopy (SEM analysis. Fungal consortium pretreatment effectively degraded oat straw lignin (by >47% in 7 days leading to decomposition of cell-wall structure as revealed in SEM images, increasing biohydrogen yield. The hydrogen produced from the fungal consortium pretreated straw increased by 165% 6 days later, and was more than produced from either a single fungi species of T. viride or P. chrysosponium pretreated straw (94% and 106%, respectively. No inhibitory effect on hydrogen production was observed.

  4. Designing on-line analyzer for coal on belt conveyor using neutron activation technique

    International Nuclear Information System (INIS)

    Rony Djokorayono; Agus Cahyono

    2014-01-01

    Basic design of on-line analyzer for coal on belt conveyor using neutron activation technique has been carried out. Compared with sampling technique, this neutron activation technique has some advantages in term of analysis accuracy and time. The design activities performed include the establishment of design requirements, functional requirements, technical requirements, technical specification, detection sub-system design, data acquisition subsystem design, and operator computer console design. This program will use Nal(Tl) scintillation detector to detect gamma-rays emitted by elements in coal due to neutron activation of a neutron source, "2"5"2Cf (Californium-252). This basic design of on-line analyzer for coal on belt conveyor using neutron activation technique should be followed up with the development of detailed design, prototype construction, and field testing. (author)

  5. Process Analytical Technology and On-Line Spectroscopic Measurements of Chemical Meat Quality

    DEFF Research Database (Denmark)

    Sørensen, Klavs Martin

    This thesis deals with process analytical technology and how it can be implemented in the meat industry through on-line grading of chemical meat quality. The focus will be on two applications, namely the rapid quality control of fat quality and the development of a method for on-line detection...... of nano-molar quantification in few seconds, in addition to an accelerated extraction-free GC-MS method that through automation can deliver results much faster than other similar methods. The implementation of these high tech methods will provide the meat industry with a leading edge not only with product...... of boar taint. The chemical makeup of fat has a large effect on meat cut quality. Fat quality has traditionally been determined by methylation of a tissue sample followed by chromatography on a GC-MS system, elucidating the composition of the individual fatty acids. As this procedure typically takes far...

  6. On-line nuclear ash gauge for coal based on gamma-ray transmission techniques

    International Nuclear Information System (INIS)

    Rizk, R.A.M.; El-Kateb, A.H.; Abdul-Kader, A.M.

    1999-01-01

    Developments and applications of on-line nuclear gauges in the coal industry are highly requested. A nuclear ash gauge for coal, based on γ-ray transmission techniques is developed. Single and dual energy γ-ray beams are used to determine the ash content of coal. The percentage ash content as a function of the γ-ray intensities transmitted through coal samples is measured and sensitivity curves are obtained. An empirical formulation relating the ash content values to the γ-ray intensities is derived. Preliminary results show that both single and dual energy γ-ray transmission techniques can be used to give a rapid on-line estimation of the ash concentration values in coal with low cost and reasonable accuracy, but the dual one is much preferable. (author)

  7. Active load sharing technique for on-line efficiency optimization in DC microgrids

    DEFF Research Database (Denmark)

    Sanseverino, E. Riva; Zizzo, G.; Boscaino, V.

    2017-01-01

    Recently, DC power distribution is gaining more and more importance over its AC counterpart achieving increased efficiency, greater flexibility, reduced volumes and capital cost. In this paper, a 24-120-325V two-level DC distribution system for home appliances, each including three parallel DC......-DC converters, is modeled. An active load sharing technique is proposed for the on-line optimization of the global efficiency of the DC distribution network. The algorithm aims at the instantaneous efficiency optimization of the whole DC network, based on the on-line load current sampling. A Look Up Table......, is created to store the real efficiencies of the converters taking into account components tolerances. A MATLAB/Simulink model of the DC distribution network has been set up and a Genetic Algorithm has been employed for the global efficiency optimization. Simulation results are shown to validate the proposed...

  8. Fundamental characteristics of microwave explosion pretreatment of wood. I, Properties of temperature development

    Science.gov (United States)

    Xian-jun Li; Ke-yang Lu; Lan-ying Lin; Yong-dong Zhou; Zhi-yong Cai; Feng Fu

    2010-01-01

    In this study, the effects of microwave radiation intensity, radiation time and initial wood moisture content (MC) on the properties of temperature development in Eucalyptus urophylla wood samples during the microwave explosion pretreatment have been investigated using a new microwave pretreatment equipment. The results show that 1) with the increase of microwave...

  9. On-line soft sensing in upstream bioprocessing.

    Science.gov (United States)

    Randek, Judit; Mandenius, Carl-Fredrik

    2018-02-01

    This review provides an overview and a critical discussion of novel possibilities of applying soft sensors for on-line monitoring and control of industrial bioprocesses. Focus is on bio-product formation in the upstream process but also the integration with other parts of the process is addressed. The term soft sensor is used for the combination of analytical hardware data (from sensors, analytical devices, instruments and actuators) with mathematical models that create new real-time information about the process. In particular, the review assesses these possibilities from an industrial perspective, including sensor performance, information value and production economy. The capabilities of existing analytical on-line techniques are scrutinized in view of their usefulness in soft sensor setups and in relation to typical needs in bioprocessing in general. The review concludes with specific recommendations for further development of soft sensors for the monitoring and control of upstream bioprocessing.

  10. On-line corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2004-01-01

    ), Electrochemical Noise (EN) and Zero Resistance Ammetry (ZRA). Electrochemical Resistance (ER) has also been used to measure corrosion. The method traditionally only measures corrosion off-line but with newly developed high-sensitive ER technique developed by MetriCorr in Denmark, on-line monitoring is possible...... complicates the chemistry of the environment. Hydrogen sulphide is present in geothermal systems and can be formed as a by-product of sulphate-reducing-bacteria (SRB). The application of electrochemical methods makes on-line monitoring possible. These methods include: Linear Polarization Resistance (LPR....... In order to assess both general corrosion and localized corrosion, it is necessary to apply more than one monitoring technique simultaneously, ZRA or EN for measuring localized corrosion and LPR or ER for measuring general corrosion rate. The advantage of monitoring localized corrosion is indisputable...

  11. On-line sources of toxicological information in Canada

    International Nuclear Information System (INIS)

    Racz, William J.; Ecobichon, Donald J.; Baril, Marc

    2003-01-01

    This paper will provide an overview of the on-line resources available in toxicology in Canada. It will describe a brief history of The Society of Toxicology of Canada, with reference to other societies and also provide information on education, research and other resources related to toxicology. Toxicology in Canada emerged as a distinct and vibrant discipline following the thalidomide tragedy of the 1960s. In the pharmaceutical industry and government, toxicology was readily established as an essential component of drug development and safety, and as the need for toxicologists expanded, training programs were established, usually in collaboration with departments of pharmacology. In the last two to three decades other disciplines, environmental biology, analytical chemistry and epidemiology joined the ranks of toxicology. The on-line sources of toxicology information are rapidly expanding. This article describes those sources considered by the authors to be important from a national and international perspective. The majority of these sources are professional organizations and government agencies

  12. On-line application of the PANTHER advanced nodal code

    International Nuclear Information System (INIS)

    Hutt, P.K.; Knight, M.P.

    1992-01-01

    Over the last few years, Nuclear Electric has developed an integrated core performance code package for both light water reactors (LWRs) and advanced gas-cooled reactors (AGRs) that can perform a comprehensive range of calculations for fuel cycle design, safety analysis, and on-line operational support for such plants. The package consists of the following codes: WIMS for lattice physics, PANTHER whole reactor nodal flux and AGR thermal hydraulics, VIPRE for LWR thermal hydraulics, and ENIGMA for fuel performance. These codes are integrated within a UNIX-based interactive system called the Reactor Physics Workbench (RPW), which provides an interactive graphic user interface and quality assurance records/data management. The RPW can also control calculational sequences and data flows. The package has been designed to run both off-line and on-line accessing plant data through the RPW

  13. UniFlex - Collaborative on-line learning environment tool

    Directory of Open Access Journals (Sweden)

    Ole Borch

    2004-05-01

    Full Text Available

    Første gang publiceret i UNEV nr. 2: E-læringsplatforme - muligheder og potentialer, januar - marts 2004, red. Tom Nyvand og Michael Pedersen. ISSN 1603-5518.

    Increasing demands for remote on-line education are changing the way teaching and learning is performed. New behavior in using pedagogy and supporting technology is needed to drive the learning process. To facilitate the use of services for selected activities to participants in distance education, a web site named UniFlex (University Flexible learning has been developed and brought into use. The site is a comprehensive set of bookmarks including course taking, upload/download, and - of special significance - collaborative on-line project work. UniFlex has been developed to meet the requirement for a simple and cheap personalized interactive site, supporting problem oriented and project organized study form, which has characterized Aalborg University for more than 27 years.

  14. UniFlex - Collaborative on-line learning environment tool

    Directory of Open Access Journals (Sweden)

    Ole Borch

    2004-03-01

    Full Text Available Første gang publiceret i UNEV nr. 2: E-læringsplatforme - muligheder og potentialer, januar - marts 2004, red. Tom Nyvand og Michael Pedersen. ISSN 1603-5518. Increasing demands for remote on-line education are changing the way teaching and learning is performed. New behavior in using pedagogy and supporting technology is needed to drive the learning process. To facilitate the use of services for selected activities to participants in distance education, a web site named UniFlex (University Flexible learning has been developed and brought into use. The site is a comprehensive set of bookmarks including course taking, upload/download, and - of special significance - collaborative on-line project work. UniFlex has been developed to meet the requirement for a simple and cheap personalized interactive site, supporting problem oriented and project organized study form, which has characterized Aalborg University for more than 27 years.

  15. On-line analyzers to distributed control system linking

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, S.F.; Buchanan, B.R.; Sanders, M.A.

    1990-01-01

    The Analytical Development Section (ADS) of the Savannah River Laboratory is developing on-line analyzers to monitor various site processes. Data from some of the on-line analyzers (OLA's) will be used for process control by distributed control systems (DCS's) such as the Fisher PRoVOX. A problem in the past has been an efficient and cost effective way to get analyzer data onto the DCS data highway. ADS is developing a system to accomplish the linking of OLA's to PRoVOX DCS's. The system will be described, and results of operation in a research and development environment given. Plans for the installation in the production environment will be discussed.

  16. On-line Ramsey Numbers for Paths and Stars

    Directory of Open Access Journals (Sweden)

    Jaroslaw Grytczuk

    2008-08-01

    Full Text Available We study on-line version of size-Ramsey numbers of graphs defined via a game played between Builder and Painter: in one round Builder joins two vertices by an edge and Painter paints it red or blue. The goal of Builder is to force Painter to create a monochromatic copy of a fixed graph H in as few rounds as possible. The minimum number of rounds (assuming both players play perfectly is the on-line Ramsey number r(H of the graph H. We determine exact values of r(H for a few short paths and obtain a general upper bound r(Pn ≤ 4n-7. We also study asymmetric version of this parameter when one of the target graphs is a star Sn with n edges. We prove that r(Sn,H≤n ·e(H when H is any tree, cycle or clique.

  17. Laser systems for on-line laser ion sources

    International Nuclear Information System (INIS)

    Geppert, Christopher

    2008-01-01

    Since its initiation in the middle of the 1980s, the resonant ionization laser ion source has been established as a reliable and efficient on-line ion source for radioactive ion beams. In comparison to other on-line ion sources it comprises the advantages of high versatility for the elements to be ionized and of high selectivity and purity for the ion beam generated by resonant laser radiation. Dye laser systems have been the predominant and pioneering working horses for laser ion source applications up to recently, but the development of all-solid-state titanium:sapphire laser systems has nowadays initiated a significant evolution within this field. In this paper an overview of the ongoing developments will be given, which have contributed to the establishment of a number of new laser ion source facilities worldwide during the last five years.

  18. On-Line Metrology with Conoscopic Holography: Beyond Triangulation

    Directory of Open Access Journals (Sweden)

    Ignacio Álvarez

    2009-09-01

    Full Text Available On-line non-contact surface inspection with high precision is still an open problem. Laser triangulation techniques are the most common solution for this kind of systems, but there exist fundamental limitations to their applicability when high precisions, long standoffs or large apertures are needed, and when there are difficult operating conditions. Other methods are, in general, not applicable in hostile environments or inadequate for on-line measurement. In this paper we review the latest research in Conoscopic Holography, an interferometric technique that has been applied successfully in this kind of applications, ranging from submicrometric roughness measurements, to long standoff sensors for surface defect detection in steel at high temperatures.

  19. On-line supercritical fluid extraction-supercritical fluid chromatography-mass spectrometry of polycyclic aromatic hydrocarbons in soil.

    Science.gov (United States)

    Wicker, A Paige; Carlton, Doug D; Tanaka, Kenichiro; Nishimura, Masayuki; Chen, Vivian; Ogura, Tairo; Hedgepeth, William; Schug, Kevin A

    2018-06-01

    On-line supercritical fluid extraction - supercritical fluid chromatography - mass spectrometry (SFE-SFC-MS) has been applied for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil. The purpose of this study was to develop and validate the first on-line SFE-SFC-MS method for the quantification of PAHs in various types of soil. By coupling the sample extraction on-line with chromatography and detection, sample preparation is minimized, diminishing sample loss and contamination, and significantly decreasing the required extraction time. Parameters for on-line extraction coupled to chromatographic analysis were optimized. The method was validated for concentrations of 10-1500 ng of PAHs per gram of soil in Certified Reference Material (CRM) sediment, clay, and sand with R 2  ≥ 0.99. Limits of detection (LOD) were found in the range of 0.001-5 ng/g, and limits of quantification (LOQ) in the range of 5-15 ng/g. The method developed in this study can be effectively applied to the study of PAHs in the environment, and may lay the foundation for further applications of on-line SFE-SFC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. The Bochum on-line data acquisition system

    International Nuclear Information System (INIS)

    Paul, H.J.; Freiesleben, H.

    1986-01-01

    We describe an on-line data acquisition system based on a PDP 11 computer with CAMAC hardware. The software fully exploits the real-time features of the RSX-11M operating system. The basic characteristics of the program package, mainly written in FORTRAN 77, are: multitasking, shared common blocks, dynamical access to CAMAC hardware and data, and command orientated user interface. The system is particularly tailored for data acquisition in list mode of up to 64 parameters. (orig.)

  1. Recovery Strategies in On-Line Service Failure

    OpenAIRE

    Ozuem, Wilson; Lancaster, Geoff

    2013-01-01

    Despite a proliferation of a number of studies on service failures and recovery in e-service settings, there is a paucity of knowledge of ways in which service failures and recovery practices are implemented in the fashion industry. Drawing on constructivist perspective, this study offers a new perspective on an effective relational mechanism that would bridge the rupture between consumers and companies particularly in the on-line fashion sector. The analysis adds to studies on service failur...

  2. Understanding Cognitive Load Using On-line Dictionaries

    OpenAIRE

    Robert F. , Dilenschneider

    2017-01-01

    Cognitive Load Theory may useful for language instructors to understand how the look up conditions ofusing an on-line dictionary might influence learning. This paper first reviews previous studies that haveinvestigated dictionary use for vocabulary acquisition and reading comprehension Second, it explainsthe various elements of Cognitive Load Theory. Third, it describes how Cognitive Load Theory appliesto language learners' to learn unknown words and comprehend texts Last, it discusses the pe...

  3. On-line diagnostics for a real time system

    International Nuclear Information System (INIS)

    Sreenivasan, P.

    1976-01-01

    The purpose of an on-line diagnostics is to infuse the ability of self diagnosing in an online computer to enhance its dependability in a real time system. Such a diagnostics evolved for the CDPS of the Fast Breeder Test Reactor at Kalpakkam is reported. The two phases of the diagnostics, i.e., the malfunction detection and post detection action are described in some detail. (A.K.)

  4. Isocele I, the Orsay synchrocyclotron on-line separator

    International Nuclear Information System (INIS)

    Caruette, A.; Ferro, A.; Foucher, R.

    1976-01-01

    The main characteristics of the isotope separator Isocele 1 are described. This medium current separator was on line with the Orsay synchrocyclotron (155 MeV p, or 210 MeV 3 He) from March 1974 up to May 1975. Results obtained with different targets (Au, Bi, Er, Pt, Sn, Th) are summarized. They confirm the efficiency of medium current separators of this type [fr

  5. A decision support system for on-line leakage localization

    OpenAIRE

    Meseguer, Jordi; Mirats-Tur, Josep M.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Pérez, Ramon; Sanz, Gerard; Ibarra, David

    2014-01-01

    This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integr...

  6. On-line learning in radial basis functions networks

    OpenAIRE

    Freeman, Jason; Saad, David

    1997-01-01

    An analytic investigation of the average case learning and generalization properties of Radial Basis Function Networks (RBFs) is presented, utilising on-line gradient descent as the learning rule. The analytic method employed allows both the calculation of generalization error and the examination of the internal dynamics of the network. The generalization error and internal dynamics are then used to examine the role of the learning rate and the specialization of the hidden units, which gives ...

  7. On-line production of [11C]cyanogen bromide

    International Nuclear Information System (INIS)

    Westerberg, G.; Laangstroem, B.

    1997-01-01

    The electrophilic labelling precursor [ 11 C]cyanogen bromide was produced in 95% radiochemical yield (decay-corrected) from hydrogen [ 11 C]cyanide within 3 min from the end of bombardment using a simple and convenient solid-phase on-line procedure. The [ 11 C]cyanogen bromide has been used in the synthesis of a number of labelled compounds for use in positron emission tomography. (author)

  8. Overestimation of the Legionella spp. load in environmental samples by quantitative real-time PCR: pretreatment with propidium monoazide as a tool for the assessment of an association between Legionella concentration and sanitary risk.

    Science.gov (United States)

    Ditommaso, Savina; Ricciardi, Elisa; Giacomuzzi, Monica; Arauco Rivera, Susan R; Ceccarelli, Adriano; Zotti, Carla M

    2014-12-01

    Quantitative polymerase chain reaction (qPCR) offers rapid, sensitive, and specific detection of Legionella in environmental water samples. In this study, qPCR and qPCR combined with propidium monoazide (PMA-qPCR) were both applied to hot-water system samples and compared to traditional culture techniques. In addition, we evaluated the ability of PMA-qPCR to monitor the efficacy of different disinfection strategies. Comparison between the quantification obtained by culture and by qPCR or PMA-qPCR on environmental water samples confirms that the concentration of Legionella estimated by GU/L is generally higher than that estimated in CFU/L. Our results on 57 hot-water-system samples collected from 3 different sites show that: i) qPCR results were on average 178-fold higher than the culture results (Δ log10=2.25), ii) PMA-qPCR results were on average 27-fold higher than the culture results (Δ log10=1.43), iii) propidium monoazide-induced signal reduction in qPCR were nearly 10-fold (Δ log10=0.95), and that iv) different degrees of correlations between the 3 methods might be explained by different matrix properties, but also by different disinfection methods affecting cultivability of Legionella. In our study, we calculated the logarithmic differences between the results obtained by PMA-qPCR and those obtained by culture, and we suggested an algorithm for the interpretation of PMA-qPCR results for the routine monitoring of healthcare water systems using a commercial qPCR system (iQ-check real-time PCR kit; Bio-Rad, Marnes-la-Coquette, France). Copyright © 2014 Elsevier Inc. All rights reserved.

  9. On-line Monitoring System for Power Transformers

    Directory of Open Access Journals (Sweden)

    Alexandru HOTEA

    2016-12-01

    Full Text Available Power transformers are the most important and expensive equipment from the electricity transmission system, so it is very important to know the real state of health of such equipment in every moment. De-energizing the power transformer accidentally due to internal defects can generate high costs. Annual maintenance proved to be ineffective in many cases to determine the internal condition of the equipment degradation due to faults rapidly evolving. An On-line Monitoring System for Power Transformers help real-time condition assessment and to detect errors early enough to take action to eliminate or minimize them. After abnormality detected, it is still important to perform full diagnostic tests to determine the exact condition of the equipment. On-line monitoring systems can help increase the level of availability and reliability of power transformers and lower costs of accidental interruption. This paper presents cases studies on several power transformers equipped with on-line monitoring systems from Transelectrica substation.

  10. Characterizing chemical systems with on-line computers and graphics

    International Nuclear Information System (INIS)

    Frazer, J.W.; Rigdon, L.P.; Brand, H.R.; Pomernacki, C.L.

    1979-01-01

    Incorporating computers and graphics on-line to chemical experiments and processes opens up new opportunities for the study and control of complex systems. Systems having many variables can be characterized even when the variable interactions are nonlinear, and the system cannot a priori be represented by numerical methods and models. That is, large sets of accurate data can be rapidly acquired, then modeling and graphic techniques can be used to obtain partial interpretation plus design of further experimentation. The experimenter can thus comparatively quickly iterate between experimentation and modeling to obtain a final solution. We have designed and characterized a versatile computer-controlled apparatus for chemical research, which incorporates on-line instrumentation and graphics. It can be used to determine the mechanism of enzyme-induced reactions or to optimize analytical methods. The apparatus can also be operated as a pilot plant to design control strategies. On-line graphics were used to display conventional plots used by biochemists and three-dimensional response-surface plots

  11. On-Line Fringe Tracking and Prediction at IOTA

    Science.gov (United States)

    Wilson, Edward; Mah, Robert; Lau, Sonie (Technical Monitor)

    1999-01-01

    The Infrared/Optical Telescope Array (IOTA) is a multi-aperture Michelson interferometer located on Mt. Hopkins near Tucson, Arizona. To enable viewing of fainter targets, an on-line fringe tracking system is presently under development at NASA Ames Research Center. The system has been developed off-line using actual data from IOTA, and is presently undergoing on-line implementation at IOTA. The system has two parts: (1) a fringe tracking system that identifies the center of a fringe packet by fitting a parametric model to the data; and (2) a fringe packet motion prediction system that uses characteristics of past fringe packets to predict fringe packet motion. Combined, this information will be used to optimize on-line the scanning trajectory, resulting in improved visibility of faint targets. Fringe packet identification is highly accurate and robust (99% of the 4000 fringe packets were identified correctly, the remaining 1% were either out of the scan range or too noisy to be seen) and is performed in 30-90 milliseconds on a Pentium II-based computer. Fringe packet prediction, currently performed using an adaptive linear predictor, delivers a 10% improvement over the baseline of predicting no motion.

  12. Review of trigger and on-line processors at SLAC

    International Nuclear Information System (INIS)

    Lankford, A.J.

    1984-07-01

    The role of trigger and on-line processors in reducing data rates to manageable proportions in e + e - physics experiments is defined not by high physics or background rates, but by the large event sizes of the general-purpose detectors employed. The rate of e + e - annihilation is low, and backgrounds are not high; yet the number of physics processes which can be studied is vast and varied. This paper begins by briefly describing the role of trigger processors in the e + e - context. The usual flow of the trigger decision process is illustrated with selected examples of SLAC trigger processing. The features are mentioned of triggering at the SLC and the trigger processing plans of the two SLC detectors: The Mark II and the SLD. The most common on-line processors at SLAC, the BADC, the SLAC Scanner Processor, the SLAC FASTBUS Controller, and the VAX CAMAC Channel, are discussed. Uses of the 168/E, 3081/E, and FASTBUS VAX processors are mentioned. The manner in which these processors are interfaced and the function they serve on line is described. Finally, the accelerator control system for the SLC is outlined. This paper is a survey in nature, and hence, relies heavily upon references to previous publications for detailed description of work mentioned here. 27 references, 9 figures, 1 table

  13. On-line plant-wide monitoring using neural networks

    International Nuclear Information System (INIS)

    Turkcan, E.; Ciftcioglu, O.; Eryurek, E.; Upadhyaya, B.R.

    1992-06-01

    The on-line signal analysis system designed for a multi-level mode operation using neural networks is described. The system is capable of monitoring the plant states by tracking different number of signals up to 32 simultaneously. The data used for this study were acquired from the Borssele Nuclear Power Plant (PWR type), and using the on-line monitoring system. An on-line plant-wide monitoring study using a multilayer neural network model is discussed in this paper. The back-propagation neural network algorithm is used for training the network. The technique assumes that each physical state of the power plant can be represented by a unique pattern of instrument readings which can be related to the condition of the plant. When disturbance occurs, the sensor readings undergo a transient, and form a different set of patterns which represent the new operational status. Diagnosing these patterns can be helpful in identifying this new state of the power plant. To this end, plant-wide monitoring with neutral networks is one of the new techniques in real-time applications. (author). 9 refs.; 5 figs

  14. Designing effective on-line continuing medical education.

    Science.gov (United States)

    Zimitat, Craig

    2001-03-01

    The Internet, and new information and communication technologies available through the Internet, provides medical educators with an opportunity to develop unique on-line learning environments with real potential to improve physicians' knowledge and effect change in their clinical practice. There are approximately 100 websites offering on-line CME courses in the USA alone. However, few of these CME courses appear to be based on sound educational principles or CME research and may have little chance of achieving the broader goals of CME. The majority of these courses closely resemble their traditional counterparts (e.g. paper-based books are now electronic books) and appear to be mere substitutions for old-technology CME resources. Whilst some CME providers add unique features of the Internet to enrich their websites, they do not employ strategies to optimize the learning opportunities afforded by this new technology. The adoption of adult learning principles, reflective practice and problem-based approaches can be used as a foundation for sound CME course design. In addition, knowledge of Internet technology and the learning opportunities it affords, together with strategies to maintain participation and new assessment paradigms, are all needed for developing online CME. We argue for an evidence-based and strategic approach to the development of on-line CME courses designed to enhance physician learning and facilitate change in clinical behaviour.

  15. On-line radiation teaching materials using IT technology

    International Nuclear Information System (INIS)

    Inoue, Hiroyoshi

    2005-01-01

    We developed the on-line radiation teaching materials using the Internet, in order to provide the teaching support materials of atomic power and radiation educations in on-school study, as well as to create the complementary study system in off-school study. The themes of teaching materials were selected from requests by teachers. In the case of an elementary school, the teaching material 'an environmental problem and atomic power' was created as the aggregate of each content for study without boundary between subjects. The teaching material 'medical treatment and radiation' was created for junior high school students to raise the individual knowledge. In the case of a high school, the teaching material nucleus and radiation' was prepared to supplement the physical study of students. The on-line teaching materials were tried to 300 junior high school and high school students, 68% of students answered that the teaching material is effective to understand atomic power and radiation, though 17% answered they were not effective. Although there are problems to prepare IT learning equipments and learning follow-up system in the material, it is suggested that the on-line teaching materials will provide the novel learning system including debates for the study. This method has no limitation of time and place. (author)

  16. On-line fouling monitor for heat exchangers

    International Nuclear Information System (INIS)

    Tsou, J.L.

    1995-01-01

    Biological and/or chemical fouling in utility service water system heat exchangers adversely affects operation and maintenance costs, and reduced heat transfer capability can force a power deaerating or even a plant shut down. In addition, service water heat exchanger performance is a safety issue for nuclear power plants, and the issue was highlighted by NRC in Generic Letter 89-13. Heat transfer losses due to fouling are difficult to measure and, usually, quantitative assessment of the impact of fouling is impossible. Plant operators typically measure inlet and outlet water temperatures and flow rates and then perform complex calculations for heat exchanger fouling resistance or ''cleanliness''. These direct estimates are often imprecise due to inadequate instrumentation. Electric Power Research Institute developed and patented an on-line condenser fouling monitor. This monitor may be installed in any location within the condenser; does not interfere with routine plant operations, including on-line mechanical and chemical treatment methods; and provides continuous, real-time readings of the heat transfer efficiency of the instrumented tube. This instrument can be modified to perform on-line monitoring of service water heat exchangers. This paper discusses the design, construction of the new monitor, and algorithm used to calculate service water heat exchanger fouling

  17. Denmark's on - line early warning radiation monitoring network

    International Nuclear Information System (INIS)

    Walmod-Larsen, O.; Lippert, J.

    1990-01-01

    In Denmark an emergency response coordination committee was set up to cope with the problems after the Chernobyl accident with participation of all relevant authorities. For help in an emergency situation the ARGOS (Accident Reporting and Guiding Operational System), system will be put into use. The ARGOS emergency evaluation computer system, which has been developed in cooperation with the Danish Environmental Protection Agency, is in operation in connection with the emergency planning for the east region of Denmark with regard to the Swedish nuclear power plant operating at Barseback. Inputs of measurement data are on-line available on data screens for evaluation in the emergency coordination centers, presented on suitable geographical maps, showing iso-contours calculated from the input. In case of an alert situation other systems can be put in operation, f.ex. mobile measuring units from the CDEPA's local, operational emergency centers. Their readings can then be put into the computing system parallel to the on-line stations and be presented by the ARGOS-system for evaluation in the emergency command centers. If another national authority in an alert situation requests a transfer of measurement data, and if this is agreed upon by the competent Danish authority, then the transfer can be arranged from the ARGOS-system, through agreed transmission channels. At present the ARGOS system is being improved and expanded by RNL to cover the whole Danish region and to present measurements from the on-line warning system

  18. The use of on-line ion chromatography for high temperature and high pressure reaction studies

    International Nuclear Information System (INIS)

    Lynch, G.J.

    1993-10-01

    This paper describes the use of on-line ion chromatography as a tool for chemistry reaction studies in small volume systems. The technique was used to study chemistry behavior in a high temperature and high pressure autoclave system. A dual analyzer, multi-channel on-line ion chromatograph (IC) was configured to automate the sampling and analysis. Analytical channels were set up for analysis of inorganic anions, monovalent cations, conductivity, and pH. Conductivity and pH were measured using the IC as a flow injection analyzer. Use of the IC system provides significant advantages over conventional sampling and analysis techniques: Reduction in sample volume, a closed sampling system that protects air or light sensitive analytes from breakdown, around-the-clock test performance combined with automatic calibration and quality control checking, and detection and tracking of reaction products or unexpected contaminants. Methods used to correct measured concentrations for the effects of sampling and for calculation of control chemical loss half-lives are presented. A limited evaluation of the flow injection analysis methods for conductivity and pH is provided

  19. Complex concentrate pretreatment

    International Nuclear Information System (INIS)

    Lokken, R.O.; Scheele, R.D.; Strachan, D.M.; Toste, A.P.

    1991-03-01

    After removal of the transuranics (TRU) by the TRUEX process, complex concentrate waste will be grouted for final storage. The purpose of this project, conducted at the Pacific Northwest Laboratory, is to support a future decision to grout the complexant waste without destruction of the organic contents. It has been demonstrated that grouts with acceptable parameters for the Transportable Grout Facility can be made using actual waste. The acceptability of these grouts from a regulatory view seems to be less of a problem than previously. None of the organics found in the waste have been found on the EPA hazardous chemicals list. Two potential problems with the processing of the complex concentrate wastes were identified during the use of the TRUEX process on samples of several milliliters. One was the amount of foam that is generated during acid addition to the alkaline waste. Some of this foam appears to be of a waxy nature but does redissolve when the waste is strongly acid. The second potential problem is that noticeable amounts of NO x gases are generated. No quantitative measure of the NO x gas generation was made. The problem relates to processing the waste in B-plant where there are no facilities to handle NO x gases. 5 refs., 4 figs., 4 tabs

  20. Evaluation of ultrasound-assisted extraction as sample pre-treatment for quantitative determination of rare earth elements in marine biological tissues by inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Costas, M.; Lavilla, I.; Gil, S.; Pena, F.; Calle, I.; Cabaleiro, N. de la; Bendicho, C.

    2010-01-01

    In this work, the determination of rare earth elements (REEs), i.e. Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu in marine biological tissues by inductively coupled-mass spectrometry (ICP-MS) after a sample preparation method based on ultrasound-assisted extraction (UAE) is described. The suitability of the extracts for ICP-MS measurements was evaluated. For that, studies were focused on the following issues: (i) use of clean up of extracts with a C18 cartridge for non-polar solid phase extraction; (ii) use of different internal standards; (iii) signal drift caused by changes in the nebulization efficiency and salt deposition on the cones during the analysis. The signal drift produced by direct introduction of biological extracts in the instrument was evaluated using a calibration verification standard for bracketing (standard-sample bracketing, SSB) and cumulative sum (CUSUM) control charts. Parameters influencing extraction such as extractant composition, mass-to-volume ratio, particle size, sonication time and sonication amplitude were optimized. Diluted single acids (HNO 3 and HCl) and mixtures (HNO 3 + HCl) were evaluated for improving the extraction efficiency. Quantitative recoveries for REEs were achieved using 5 mL of 3% (v/v) HNO 3 + 2% (v/v) HCl, particle size <200 μm, 3 min of sonication time and 50% of sonication amplitude. Precision, expressed as relative standard deviation from three independent extractions, ranged from 0.1 to 8%. In general, LODs were improved by a factor of 5 in comparison with those obtained after microwave-assisted digestion (MAD). The accuracy of the method was evaluated using the CRM BCR-668 (mussel tissue). Different seafood samples of common consumption were analyzed by ICP-MS after UAE and MAD.

  1. Hydrothermal pretreatment of coal

    Energy Technology Data Exchange (ETDEWEB)

    Ross, D.S.

    1989-12-21

    We have examined changes in Argonne Premium samples of Wyodak coal following 30 min treatment in liquid water at autogenous pressures at 150{degrees}, 250{degrees}, and 350{degrees}C. In most runs the coal was initially dried at 60{degrees}C/1 torr/20 hr. The changes were monitored by pyrolysis field ionization mass spectrometry (py-FIMS) operating at 2.5{degrees}C/min from ambient to 500{degrees}C. We recorded the volatility patterns of the coal tars evolved over that temperature range, and in all cases the tar yields were 25%--30% of the starting coal on mass basis. There was essentially no change after the 150{degrees}C treatment. Small increases in volatility were seen following the 250{degrees}C treatment, but major effects were seen in the 350{degrees} work. The tar quantity remained unchanged; however, the volatility increased so the temperature of half volatility for the as-received coal of 400{degrees}C was reduced to 340{degrees}C. Control runs with no water showed some thermal effect, but the net effect from the presence of liquid water was clearly evident. The composition was unchanged after the 150{degrees} and 250{degrees}C treatments, but the 350{degrees} treatment brought about a 30% loss of oxygen. The change corresponded to loss of the elements of water, although loss of OH'' seemed to fit the analysis data somewhat better. The water loss takes place both in the presence and in the absence of added water, but it is noteworthy that the loss in the hydrothermal runs occurs at p(H{sub 2}O) = 160 atm. We conclude that the process must involve the dehydration solely of chemically bound elements of water, the dehydration of catechol is a specific, likely candidate.

  2. Local high precision 3D measurement based on line laser measuring instrument

    Science.gov (United States)

    Zhang, Renwei; Liu, Wei; Lu, Yongkang; Zhang, Yang; Ma, Jianwei; Jia, Zhenyuan

    2018-03-01

    In order to realize the precision machining and assembly of the parts, the geometrical dimensions of the surface of the local assembly surfaces need to be strictly guaranteed. In this paper, a local high-precision three-dimensional measurement method based on line laser measuring instrument is proposed to achieve a high degree of accuracy of the three-dimensional reconstruction of the surface. Aiming at the problem of two-dimensional line laser measuring instrument which lacks one-dimensional high-precision information, a local three-dimensional profile measuring system based on an accurate single-axis controller is proposed. First of all, a three-dimensional data compensation method based on spatial multi-angle line laser measuring instrument is proposed to achieve the high-precision measurement of the default axis. Through the pretreatment of the 3D point cloud information, the measurement points can be restored accurately. Finally, the target spherical surface is needed to make local three-dimensional scanning measurements for accuracy verification. The experimental results show that this scheme can get the local three-dimensional information of the target quickly and accurately, and achieves the purpose of gaining the information and compensating the error for laser scanner information, and improves the local measurement accuracy.

  3. Comparing the happiness effects of real and on-line friends.

    Directory of Open Access Journals (Sweden)

    John F Helliwell

    Full Text Available A recent large Canadian survey permits us to compare face-to-face ('real-life' and on-line social networks as sources of subjective well-being. The sample of 5,000 is drawn randomly from an on-line pool of respondents, a group well placed to have and value on-line friendships. We find three key results. First, the number of real-life friends is positively correlated with subjective well-being (SWB even after controlling for income, demographic variables and personality differences. Doubling the number of friends in real life has an equivalent effect on well-being as a 50% increase in income. Second, the size of online networks is largely uncorrelated with subjective well-being. Third, we find that real-life friends are much more important for people who are single, divorced, separated or widowed than they are for people who are married or living with a partner. Findings from large international surveys (the European Social Surveys 2002-2008 are used to confirm the importance of real-life social networks to SWB; they also indicate a significantly smaller value of social networks to married or partnered couples.

  4. On-line signature verification using Gaussian Mixture Models and small-sample learning strategies

    Directory of Open Access Journals (Sweden)

    Gabriel Jaime Zapata-Zapata

    2016-01-01

    Full Text Available El artículo aborda el problema de entrenamiento de sistemas de verificación de firmas en línea cuando el número de muestras disponibles para el entrenamiento es bajo, debido a que en la mayoría de situaciones reales el número de firmas disponibles por usuario es muy limitado. El artículo evalúa nueve diferentes estrategias de clasificación basadas en modelos de mezclas de Gaussianas (GMM por sus siglas en inglés y la estrategia conocida como modelo histórico universal (UBM por sus siglas en inglés, la cual está diseñada con el objetivo de trabajar bajo condiciones de menor número de muestras. Las estrategias de aprendizaje de los GMM incluyen el algoritmo convencional de Esperanza y Maximización, y una aproximación Bayesiana basada en aprendizaje variacional. Las firmas son caracterizadas principalmente en términos de velocidades y aceleraciones de los patrones de escritura a mano de los usuarios. Los resultados muestran que cuando se evalúa el sistema en una configuración genuino vs. impostor, el método GMM-UBM es capaz de mantener una precisión por encima del 93%, incluso en casos en los que únicamente se usa para entrenamiento el 20% de las muestras disponibles (equivalente a 5 firmas, mientras que la combinación de un modelo Bayesiano UBM con una Máquina de Soporte Vectorial (SVM por sus siglas en inglés, modelo conocido como GMM-Supervector, logra un 99% de acierto cuando las muestras de entrenamiento exceden las 20. Por otro lado, cuando se simula un ambiente real en el que no están disponibles muestras impostoras y se usa

  5. In the Jungle of Astronomical On--line Data Services

    Science.gov (United States)

    Egret, D.

    The author tried to survive in the jungle of astronomical on--line data services. In order to find efficient answers to common scientific data retrieval requests, he had to collect many pieces of information, in order to formulate typical user scenarios, and try them against a number of different data bases, catalogue services, or information systems. He discovered soon how frustrating treasure coffers may be when their keys are not available, but he realized also that nice widgets and gadgets are of no help when the information is not there. And, before long, he knew he would have to navigate through several systems because no one was yet offering a general answer to all his questions. I will present examples of common user scenarios and show how they were tested against a number of services. I will propose some elements of classification which should help the end-user to evaluate how adequate the different services may be for providing satisfying answers to specific queries. For that, many aspects of the user interaction will be considered: documentation, access, query formulation, functionalities, qualification of the data, overall efficiency, etc. I will also suggest possible improvements to the present situation: the first of them being to encourage system managers to increase collaboration between one another, for the benefit of the whole astronomical community. The subjective review I will present, is based on publicly available astronomical on--line services from the U.S. and from Europe, most of which (excepting the newcomers) were described in ``Databases and On-Line Data in Astronomy", (Albrecht & Egret, eds, 1991): this includes databases (such as NED and Simbad ), catalog services ( StarCat , DIRA , XCatScan , etc.), and information systems ( ADS and ESIS ).

  6. On-line implant reconstruction in HDR brachytherapy

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Kruijf, Wilhelmus J.M. de; Levendag, Peter C.

    2006-01-01

    Background and purpose: To evaluate the accuracy of on-line planning in an Integrated Brachytherapy Unit (IBU) using dedicated image distortion correction algorithms, correcting the geometric distortion and magnetic distortion separately, and to determine the effect of the reconstruction accuracy on clinical treatment plans in terms of deviations in treatment time and dose. Patients and methods: The reconstruction accuracy has been measured using 20 markers, positioned at well known locations in a QA phantom. Treatment plans of two phantoms representing clinical implant geometries, have been compared with reference plans to determine the effect of the reconstruction accuracy on the treatment plan. Before clinical introduction, treatment plans of three representative patients, based on on-line reconstruction, have been compared with reference plans. Results: The average reconstruction error for 10 in. images reduces from -0.6 mm (range -2.6 to +1.0 mm) to -0.2 mm (range -1.2 to +0.6 mm) after image distortion correction and for 15 in. images from 0.8 mm (range -0.5 to +3.0 mm) to 0.0 mm (range -0.8 to +0.8 mm). The error in case of eccentric positioning of the phantom, i.e. 0.8 mm (range -1.0 to +3.3 mm), reduces to 0.1 mm (range -0.5 to +0.9 mm). Correction of the image distortions reduces the deviation in the calculated treatment time of maximally 2.7% to less than 0.8% in case of eccentrically positioned clinical phantoms. The deviation in the treatment time or reference dose in the plans based on on-line reconstruction with image distortion correction of the three patient examples is smaller than 0.3%. Conclusions: Accurate on-line implant reconstruction using the IBU localiser and dedicated correction algorithms separating the geometric distortion and the magnetic distortion is possible. The results fulfill the minimum requirements as imposed by the Netherlands Commission on Radiation Dosimetry (NCS) without limitations regarding the usable range of the field

  7. On-line data processing for scintillation camera

    International Nuclear Information System (INIS)

    Ueyanagi, Hideo

    1974-01-01

    To process on-line the information from scintillation cameras, the computing/processing device of wired program type, with a specialized mini-computer for the processing, is generally used; and by this method, the data processing is done by the users of scintillation cameras. In the device with a mini-computer with processing programming by software, the almost all items in processing can be executed; but the operation requires some skill. With mini-computer operation, on the other hand, there are the problems of data-point number, process-time reduction, and image storage for both long and short terms. (Mori, K.)

  8. Robust Control Methods for On-Line Statistical Learning

    Directory of Open Access Journals (Sweden)

    Capobianco Enrico

    2001-01-01

    Full Text Available The issue of controlling that data processing in an experiment results not affected by the presence of outliers is relevant for statistical control and learning studies. Learning schemes should thus be tested for their capacity of handling outliers in the observed training set so to achieve reliable estimates with respect to the crucial bias and variance aspects. We describe possible ways of endowing neural networks with statistically robust properties by defining feasible error criteria. It is convenient to cast neural nets in state space representations and apply both Kalman filter and stochastic approximation procedures in order to suggest statistically robustified solutions for on-line learning.

  9. Development of an on-line radon monitoring system

    International Nuclear Information System (INIS)

    Guo Huiping; Shang Aiguo; Liu Junfeng; Zhou Chunlin; Di Yuming

    2004-01-01

    Of the actual demand by the strategic missile troops, the author has successfully developed a specially designed passive diffusion collecting chamber to collect the decay products of radon by high voltage static electricity, and using the single-chip microcomputer to reckon the radon concentration in air, which is actually a portable, continuous and automatic on-line monitoring instrument. It was made into a four-slot standard plug-in board of a NIM, and it functions as auto data memory, data process, display, over-threshold alarming and so on. (authors)

  10. Integrated on-line accelerator modeling at CEBAF

    International Nuclear Information System (INIS)

    Bowling, B.A.; Shoaee, H.; Van Zeijts, J.; Witherspoon, S.; Watson, W.

    1995-01-01

    An on-line accelerator modeling facility is currently under development at CEBAF. The model server, which is integrated with the EPICS control system, provides coupled and 2nd-order matrices for the entire accelerator, and forms the foundation for automated model- based control and diagnostic applications. Four types of machine models are provided, including design, golden or certified, live, and scratch or simulated model. Provisions are also made for the use of multiple lattice modeling programs such as DIMAD, PARMELA, and TLIE. Design and implementation details are discussed. 2 refs., 4 figs

  11. On-line Dynamic Security Assessment in Power Systems

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel

    and solar radiation. Moreover, ongoing research suggests that demand response will be introduced to maintain power balance between generation and consumption at all times. Due to these changes the operating point of the power system will be less predictable and today’s stability and security assessment...... for early prediction of critical voltage sags is described. The method’s performance is compared to other prediction approaches. The results show that the proposed method succeeds in early, accurately and consistently predicting critically low voltage sags. An efficient on-line DSA not only identifies...

  12. Enhancing Learner Autonomy in an On-line Editing Programme

    Directory of Open Access Journals (Sweden)

    Hebe Wong

    2011-09-01

    Full Text Available Little (1999 argues that in formal educational contexts, “the basis of learner autonomy is acceptance of responsibility for one’s own learning” (p.11. An autonomous learner takes responsibility for various aspects of learning (Benson & Voller, 1997; Holec, 1981. This study examines how learner autonomy opportunities were provided at various stages of writing in an on-line editing programme for a group of electronic engineering students and how the students took charge of their language learning when receiving feedback on their technical writing. The impact on their own learning effectiveness of the decisions students made is also discussed.

  13. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2007-12-01

    (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  14. On-line core monitoring with CORE MASTER / PRESTO

    International Nuclear Information System (INIS)

    Lindahl, S.O.; Borresen, S.; Ovrum, S.

    1986-01-01

    Advanced calculational tools are instrumental in improving reactor plant capacity factors and fuel utilization. The computer code package CORE MASTER is an integrated system designed to achieve this objective. The system covers all main activities in the area of in-core fuel management for boiling water reactors; design, operation support, and on-line core monitoring. CORE MASTER operates on a common data base, which defines the reactor and documents the operating history of the core and of all fuel bundles ever used

  15. Core on-line monitoring and computerized procedures systems

    International Nuclear Information System (INIS)

    Gangloff, W.C.

    1986-01-01

    The availability of operating nuclear power plants has been affected significantly by the difficulty people have in coping with the complexity of the plants and the operating procedures. Two ways to use modern computer technology to ease the burden of coping are discussed in this paper, an on-line core monitoring system with predictive capability and a computerized procedures system using live plant data. These systems reduce human errors by presenting information rather than simply data, using the computer to manipulate the data, but leaving the decisions to the plant operator

  16. Lower Bounds and Semi On-line Multiprocessor Scheduling

    Directory of Open Access Journals (Sweden)

    T.C. Edwin Cheng

    2003-10-01

    Full Text Available We are given a set of identical machines and a sequence of jobs from which we know the sum of the job weights in advance. The jobs have to be assigned on-line to one of the machines and the objective is to minimize the makespan. An algorithm with performance ratio 1.6 and a lower bound of 1.5 is presented. This improves recent results by Azar and Regev who published an algorithm with performance ratio 1.625 for the less general problem that the optimal makespan is known in advance.

  17. Adaptive calibration method with on-line growing complexity

    Directory of Open Access Journals (Sweden)

    Šika Z.

    2011-12-01

    Full Text Available This paper describes a modified variant of a kinematical calibration algorithm. In the beginning, a brief review of the calibration algorithm and its simple modification are described. As the described calibration modification uses some ideas used by the Lolimot algorithm, the algorithm is described and explained. Main topic of this paper is a description of a synthesis of the Lolimot-based calibration that leads to an adaptive algorithm with an on-line growing complexity. The paper contains a comparison of simple examples results and a discussion. A note about future research topics is also included.

  18. NNDC [National Nuclear Data Center] on-line services documentation

    International Nuclear Information System (INIS)

    Dunford, C.L.; Burrows, T.W.; Tuli, J.K.

    1987-01-01

    This document summarizes and describes how to access the on-line services available from the National Nuclear Data Center (NNDC) located at Brookhaven National Laboratory. The services are available free of cost to US Department of Energy, its contractors and others who support the NNDC or supply data to the NNDC. Four of the center's data bases are now accessible to non-NNDC scientists via remote connection to the center's VAX 11/780. To use this service, you must have a terminal with access by either a telephone line or the PHYSNET network. A VT100 terminal or a terminal with VT-100 emulation is recommended but not required

  19. Efficient and Secure Comparison for On-Line Auctions

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Krøigaard, Mikkel; Geisler, Martin Joakim

    2007-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption. We also propose a homomorphic encryption scheme that can be used in our protocol and makes it more efficient than previous solutions. Our protocol is well-suited for application in on-line auctions, both...... with respect to functionality and performance. It minimizes the amount of information bidders need to send, and for comparison of 16 bit numbers with security based on 1024 bit RSA (executed by two parties), our implementation takes 0.28 seconds including all computation and communication. Using precomputation...

  20. On-line computing in a classified environment

    International Nuclear Information System (INIS)

    O'Callaghan, P.B.

    1982-01-01

    Westinghouse Hanford Company (WHC) recently developed a Department of Energy (DOE) approved real-time, on-line computer system to control nuclear material. The system simultaneously processes both classified and unclassified information. Implementation of this system required application of many security techniques. The system has a secure, but user friendly interface. Many software applications protect the integrity of the data base from malevolent or accidental errors. Programming practices ensure the integrity of the computer system software. The audit trail and the reports generation capability record user actions and status of the nuclear material inventory

  1. On-line fatigue monitoring and margins probabilistic assessment

    International Nuclear Information System (INIS)

    Fournier, I.; Morilhat, P.

    1993-01-01

    An on-line computer aided system has been developed by Electricite de France, the French utility, for a fatigue monitoring of critical locations in the nuclear steam supply system. This tool, called fatiguemeter, includes as input data only existing plant parameters and is based on some conservative assumptions at several steps of the damage assessment (thermal boundary conditions, stress computation...). This paper presents recent developments performed toward a better assessing of margins involved in the complete analysis. The methodology is enlightened with an example showing the influence of plant parameters incertitude on the final stress computed at a PWR 900 MW unit pressurizer surge line nozzle. (author)

  2. On-line system for investigation of atomic structure

    International Nuclear Information System (INIS)

    Amus'ya, M.Ya.; Chernysheva, L.V.

    1983-01-01

    A description of the on-line ATOM system is presented that enables to investigate the structure of atomic electron shells and their interactions with different scattering particles-electrons, positronse photons, mesons - with the use of computerized numerical solutions. The problem is stated along with mathematical description of atomic properties including theoretical and numerical models for each investigated physical process. The ATOM system structure is considered. The Hartree-Fock method is used to determine the wave functions of the ground and excited atomic states. The programs are written in the ALGOL langauge. Different atomic characteristics were possible to be calculated for the first time with an accuracy exceeding an experimental one

  3. ELT-MELAS analyzer and its on-line programs

    International Nuclear Information System (INIS)

    Anikeev, V.B.; Berezhnoj, V.A.; Glupova

    1976-01-01

    ELT-MELAS device constructed for an automatic analysis of pictures from big bubble chambers is described. It is controlled by a medium-size ICL-1903A computer and has two measuring modes: analysis of the ''agreement'' signal and digitation of slice-scans. Main features of the hardware and of on-line controlling and diagnostic software are presented. The test results of the MELAS complex as well as preliminary results of the scan-slice measurements of pictures from 15sup(') chamber are given

  4. Enzymatic hydrolsis of pretreated rice straw

    Energy Technology Data Exchange (ETDEWEB)

    Vlasenko, E.Y.; Shoemaker, S.P. [California Inst. of Food and Agricultural Research, Davis, CA (United States); Ding, H. [California Univ., Davis (Canada). Dept. of Food Science and Technology; Labavitch, J.M. [California Univ., Davis, CA (United States). Dept. of Pomology

    1997-02-01

    California rice straw is being evaluated as a feedstock for production of power and fuel. This paper examines the initial steps in the process: pretreatment of rice straw and enzymatic hydrolysis of the polysaccharides in the pretreated material to soluble sugars. Rice straw was subjected to three distinct pretreatment procedures: acid-catalyzed steam explosion (Swan Biomass Company), acid hydrolysis (U.S. DOE National Renewable Energy Laboratory), and ammonia fiber explosion or AFEX (Texas A and M University). Standard conditions for each pretreatment were used, but none was optimized for rice straw specifically. Six commercial cellulases, products of Genencor International (USA), Novo (Denmark), Iogen (Canada) and Fermtech (Russia) were used for hydrolysis. The Swan- and the acid-pretreatments effectively removed hemicellulose from rice straw, providing high yields of fermentable sugars. The AFEX-pretreatment was distinctly different from other pretreatments in that it did not significantly solubilize hemicellulose. All three pretreatment procedures substantially increased enzymatic digestibility of rice straw. Three commercial Trichoderma-reesei-derived enzyme preparations: Cellulase 100L (Iogen), Spezyme CP (Genencor), and Al (Fermtech), were more active on pretreated rice straw compared than others tested. Conditions for hydrolysis of rice straw using Cellulase 100L were evaluated. The supplementation of this enzyme preparation with cellobiase (Novozyme 188) significantly improved the parameters of hydrolysis for the Swan- and the acid-pretreated materials, but did not affect the hydrolysis of the AFEX-pretreated rice straw. (Author)

  5. Pretreatment Solution for Water Recovery Systems

    Science.gov (United States)

    Muirhead, Dean (Inventor)

    2018-01-01

    Chemical pretreatments are used to produce usable water by treating a water source with a chemical pretreatment that contains a hexavalent chromium and an acid to generate a treated water source, wherein the concentration of sulfate compounds in the acid is negligible, and wherein the treated water source remains substantially free of precipitates after the addition of the chemical pretreatment. Other methods include reducing the pH in urine to be distilled for potable water extraction by pretreating the urine before distillation with a pretreatment solution comprising one or more acid sources selected from a group consisting of phosphoric acid, hydrochloric acid, and nitric acid, wherein the urine remains substantially precipitate free after the addition of the pretreatment solution. Another method described comprises a process for reducing precipitation in urine to be processed for water extraction by mixing the urine with a pretreatment solution comprising hexavalent chromium compound and phosphoric acid.

  6. Face-to-Face vs On-Line: An Analysis of Profile, Learning, Performance and Satisfaction among Post Graduate Students

    Science.gov (United States)

    Ortega-Maldonado, Alberto; Llorens, Susana; Acosta, Hedy; Coo, Cristián

    2017-01-01

    The aim of this study is to explore the differences between face-to-face and on-line students in a post graduate education program. The variables considered are Post Graduate Student's profile, competences and learning outcomes, academic performance and satisfaction. The sample was composed by 47 students (64% face-to-face). Analysis of variance…

  7. Flow injection on-line preconcentration of low levels of Cr(VI) with detection by ETAAS

    DEFF Research Database (Denmark)

    Som-aum, Waraporn; Liawruangrath, Saisunee; Hansen, Elo Harald

    2002-01-01

    A flow injection (FI) on-line sorption preconcentration procedure utilizing a packed column reactor and combined with electrothermal atomic absorption spectrometry (ETAAS) is proposed for the determination of low levels of Cr(VI) in water samples. Polytetrafluoroethylene (PTFE) beads packed in a ...

  8. Comportamento do Consumidor On-line: a perspectiva da teoria do fluxoOn-line Consumer Behavior: the flow theory perspectiveComportamiento del consumidor On-line: la perspectiva de la teoría del flujo

    Directory of Open Access Journals (Sweden)

    FARIAS, Salomão Alencar de

    2008-03-01

    is its applicableness for achieving consumer satisfaction in the purchase by the Internet. It was used a descriptive methodology with the application of a survey to a sample of 237 electronic retail consumers. Collected data was analyzed by means of multivariate statistical techniques and results indicated that the on-line environment and the telepresence precede the flow, that in turn is associated to the exploratory behavior, positive effect of the navigation process, purchase and satisfaction with the purchase process.RESUMENEste artículo investiga el comportamiento del consumidor por Internet con base en el flujo, definido como la sensación holística que las personas sienten cuando realizan una actividad totalmente involucradas (CSIKSZENTMIHALYI, 1975. Esta teoría se utiliza para comprender mejor la conducta de compra por medio de la Internet, aunque este concepto todavía no esté muy claro en la literatura sobre el comportamiento del consumidor, puesto que no existe un consenso con respecto a los factores que preceden, caracterizan o son consecuencia del estado de flujo. De este modo, esta investigación buscó identificar los constructos relacionados con el estado de flujo que deben formar parte del esquema de comportamiento de la compra on line, además de indicar cuál es su aplicabilidad para obtención de la satisfacción del consumidor en la compra por la red. Fue utilizada una metodología del carácter descriptivo mediante aplicación de survey a una muestra de 237 consumidores de venta electrónica al por menor. Los datos recogidos se analizaron por medio de técnicas estadísticas multivariadas. Los resultados indicaron que el ambiente on line y la telepresencia preceden al flujo, que a su vez está asociado a la conducta exploratoria, un efecto positivo del proceso de navegación, compra y satisfacción con el proceso de compra.

  9. Human comment dynamics in on-line social systems

    Science.gov (United States)

    Wu, Ye; Zhou, Changsong; Chen, Maoying; Xiao, Jinghua; Kurths, Jürgen

    2010-12-01

    Human comment is studied using data from ‘tianya’ which is one of the most popular on-line social systems in China. We found that the time interval between two consecutive comments on the same topic, called inter-event time, follows a power-law distribution. This result shows that there is no characteristic decay time on a topic. It allows for very long periods without comments that separate bursts of intensive comments. Furthermore, the frequency of a different ID commenting on a topic also follows a power-law distribution. It indicates that there are some “hubs” in the topic who lead the direction of the public opinion. Based on the personal comments habit, a model is introduced to explain these phenomena. The numerical simulations of the model fit well with the empirical results. Our findings are helpful for discovering regular patterns of human behavior in on-line society and the evolution of the public opinion on the virtual as well as real society.

  10. On-Line Core Thermal-Hydraulic Model Improvement

    International Nuclear Information System (INIS)

    In, Wang Kee; Chun, Tae Hyun; Oh, Dong Seok; Shin, Chang Hwan; Hwang, Dae Hyun; Seo, Kyung Won

    2007-02-01

    The objective of this project is to implement a fast-running 4-channel based code CETOP-D in an advanced reactor core protection calculator system(RCOPS). The part required for the on-line calculation of DNBR were extracted from the source of the CETOP-D code based on analysis of the CETOP-D code. The CETOP-D code was revised to maintain the input and output variables which are the same as in CPC DNBR module. Since the DNBR module performs a complex calculation, it is divided into sub-modules per major calculation step. The functional design requirements for the DNBR module is documented and the values of the database(DB) constants were decided. This project also developed a Fortran module(BEST) of the RCOPS Fortran Simulator and a computer code RCOPS-SDNBR to independently calculate DNBR. A test was also conducted to verify the functional design and DB of thermal-hydraulic model which is necessary to calculate the DNBR on-line in RCOPS. The DNBR margin is expected to increase by 2%-3% once the CETOP-D code is used to calculate the RCOPS DNBR. It should be noted that the final DNBR margin improvement could be determined in the future based on overall uncertainty analysis of the RCOPS

  11. Utilities enticing customers to come on-line

    International Nuclear Information System (INIS)

    Anon

    2000-01-01

    The first tentative steps by electric utilities to offer customer services on-line is reported. While most of the on-line communications to date has been merely to present information about products and services, at least a few utilities, -- Newfoundland Power being one of them -- are now offering customers the opportunity to check on their account status, to make inquiries, and on a voluntary basis employees of the utility can receive their bills on the web. BC Hydro is even more advanced; it has offered a similar service since 1997. The option to pay bills at the BC Hydro website is coming shortly. U. S. utility companies are reported to be far more advanced in the use of the Internet; according to a study by Deloitte Consulting, U.S. utilities are advancing to the next stage wherein Web intermediaries will be offering 'shop bots' that do comparison shopping on behalf of a customer, including bidding for power on a customer's behalf at energy auctions, reverse auctions, where sellers are bidding for customers' services, and buyers clubs where customers join together to take advantage of volume buying power

  12. On-line monitoring and inservice inspection in codes

    International Nuclear Information System (INIS)

    Bartonicek, J.; Zaiss, W.; Bath, H.R.

    1999-01-01

    The relevant regulatory codes determine the ISI tasks and the time intervals for recurrent components testing for evaluation of operation-induced damaging or ageing in order to ensure component integrity on the basis of the last available quality data. In-service quality monitoring is carried out through on-line monitoring and recurrent testing. The requirements defined by the engineering codes elaborated by various institutions are comparable, with the KTA nuclear engineering and safety codes being the most complete provisions for quality evaluation and assurance after different, defined service periods. German conventional codes for assuring component integrity provide exclusively for recurrent inspection regimes (mainly pressure tests and optical testing). The requirements defined in the KTA codes however always demanded more specific inspections relying on recurrent testing as well as on-line monitoring. Foreign codes for ensuring component integrity concentrate on NDE tasks at regular time intervals, with time intervals scope of testing activities being defined on the basis of the ASME code, section XI. (orig./CB) [de

  13. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  14. Aria Sardinia: the on line community joining tradition and innovatiom

    Directory of Open Access Journals (Sweden)

    Fabrizio Lao

    2005-12-01

    Full Text Available The "ARIA Sardinia" project (Network Actions for Italians Abroad has been especially designed to integrate and give value to the network of relationships between public administrations, local socio-economic stakeholders and Italian communities abroad, this goal to be pursued with the support of new technologies and learning approaches emerging within the context of on line interest communities. The general objective of the project is the development of competencies and knowledge, intended to combine specific technical skills with local "territorial knowledge", in a process where the strengthening and the dissemination of these forms of culture come from the prompt use of innovative tools. The main activities of the project are the actions intended to guide and assist entrepreneurs, associations, development projects' partners or promoters in the path of acquisition and dissemination of the competencies which are necessary to the involvement of Italians abroad into the internationalization process of Sardinian economy. ARIA Sardinia was funded by the Italian Foreign Affairs Ministry and the European Social Fund (FSE, within the framework of the National Operational Program for Technical Assistance and System Action (PON ATAS aimed at specific promotion initiatives and fostering of permanent links between Southern Italy economy and Italians living abroad. Keywords: on line community, networking, Italians abroad, Sardinian economy, Sardinia, culture.

  15. On-Line Core Thermal-Hydraulic Model Improvement

    Energy Technology Data Exchange (ETDEWEB)

    In, Wang Kee; Chun, Tae Hyun; Oh, Dong Seok; Shin, Chang Hwan; Hwang, Dae Hyun; Seo, Kyung Won

    2007-02-15

    The objective of this project is to implement a fast-running 4-channel based code CETOP-D in an advanced reactor core protection calculator system(RCOPS). The part required for the on-line calculation of DNBR were extracted from the source of the CETOP-D code based on analysis of the CETOP-D code. The CETOP-D code was revised to maintain the input and output variables which are the same as in CPC DNBR module. Since the DNBR module performs a complex calculation, it is divided into sub-modules per major calculation step. The functional design requirements for the DNBR module is documented and the values of the database(DB) constants were decided. This project also developed a Fortran module(BEST) of the RCOPS Fortran Simulator and a computer code RCOPS-SDNBR to independently calculate DNBR. A test was also conducted to verify the functional design and DB of thermal-hydraulic model which is necessary to calculate the DNBR on-line in RCOPS. The DNBR margin is expected to increase by 2%-3% once the CETOP-D code is used to calculate the RCOPS DNBR. It should be noted that the final DNBR margin improvement could be determined in the future based on overall uncertainty analysis of the RCOPS.

  16. The Automated Threaded Fastening Based on On-line Identification

    Directory of Open Access Journals (Sweden)

    Nicolas Ivan Giannoccaro

    2008-11-01

    Full Text Available The principle of the thread fastenings have been known and used for decades with the purpose of joining one component to another. Threaded fastenings are popular because they permit easy disassembly for maintenance, repair, relocation and recycling. Screw insertions are typically carried out manually. It is a difficult problem to automat. As a result there is very little published research on automating threaded fastenings, and most research on automated assembly focus on the peg-in-hole assembly problem. This paper investigates the problem of automated monitoring of the screw insertion process. The monitoring problem deals with predicting integrity of a threaded insertion, based on the torque vs. insertion depth curve generated during the insertions. The authors have developed an analytical model to predict the torque signature signals during self-tapping screw insertions. However, the model requires parameters on the screw dimensions and plate material properties are difficult to measure. This paper presents a study on on-line identification during screw fastenings. An identification methodology for two unknown parameter estimation during a self-tapping screw insertion process is presented. It is shown that friction and screw properties required by the model can be reliably estimated on-line. Experimental results are presented to validate the identification procedure.

  17. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  18. On-line optimal control improves gas processing

    International Nuclear Information System (INIS)

    Berkowitz, P.N.; Papadopoulos, M.N.

    1992-01-01

    This paper reports that the authors' companies jointly funded the first phase of a gas processing liquids optimization project that has the specific purposes to: Improve the return of processing natural gas liquids, Develop sets of control algorithms, Make available a low-cost solution suitable for small to medium-sized gas processing plants, Test and demonstrate the feasibility of line control. The ARCO Willard CO 2 gas recovery processing plant was chosen as the initial test site to demonstrate the application of multivariable on-line optimal control. One objective of this project is to support an R ampersand D effort to provide a standardized solution to the various types of gas processing plants in the U.S. Processes involved in these gas plants include cryogenic separations, demethanization, lean oil absorption, fractionation and gas treating. Next, the proposed solutions had to be simple yet comprehensive enough to allow an operator to maintain product specifications while operating over a wide range of gas input flow and composition. This had to be a supervisors system that remained on-line more than 95% of the time, and achieved reduced plant operating variability and improved variable cost control. It took more than a year to study various gas processes and to develop a control approach before a real application was finally exercised. An initial process for C 2 and CO 2 recoveries was chosen

  19. Amdel on-line analyser at Rooiberg Tin Limited

    International Nuclear Information System (INIS)

    Owen, T.V.

    1987-01-01

    An Amdel on line analysis system was installed on the 'A' mine tin flotation plant at Rooiberg in April 1984. The motivation for the installation was made on account of the large variations in the feed grade to the plant and the resulting need for rapid operational adjustments to control concentrate grades thereby maximising the financial returns. An 'on-line' analyser system presented itself as a suitable alternative to the existing control method of smaller laboratory x-ray fluorescence analysers. On the system as installed at Rooiberg, two probes were fitted in each analysis zone, viz a density probe using high energy gamma radiation from a Cesium 127 source and a specific element absorption probe using low energy gamma radiation from a Americium 241 source. The signals as received from the probes are fed to a line receiver unit in the control room where a micro computer is doing the processing and prints out the information as required. Several advantages of this type of installation were gained at Rooiberg Tin Limited

  20. On-line Social Interactions and Executive Functions

    Directory of Open Access Journals (Sweden)

    Oscar eYbarra

    2012-04-01

    Full Text Available A successful social interaction requires fast, on-line, and active construction of an ever-changing mental-model of another’s person beliefs, expectations, emotions, and desires. It also requires the ability to inhibit inappropriate behaviors, problem-solve, take-turns, and pursue goals in a distraction-rich environment. All these tasks rely on executive functions (EF—working memory, attention/cognitive control, and inhibition. Executive functioning has long been viewed as relatively static. However, starting with recent reports of successful cognitive interventions, this view is changing and now EFs are seen as much more open to both short and long term training, warm-up, and exhaustion effects. Some of the most intriguing evidence comes from research showing how social interaction enhances performance on standard EF tests. Interestingly, the latest research indicates these EF benefits are selectively conferred by certain on-line, dynamic social interactions, which require participants to engage with another person and actively construct the model of their mind. We review this literature and highlight its connection with evolutionary and cultural theories emphasizing links between intelligence and social life.

  1. Project development and commercialisation of on-line analysis systems

    International Nuclear Information System (INIS)

    Watt, J.S.

    2000-01-01

    A project team first in the Australian Atomic Energy Commission (AAEC) and since 1982 in CSIRO has developed many on-line analysis systems for the mineral and energy industries. The development of these projects, usually lasting 7-10 years, has followed a common pattern of laboratory R and D, field trials, commercialisation and technology transfer. This successful pattern is illustrated using examples of the development of systems for the on-line analysis of mineral slurries, for determination of the ash content of coal on conveyors, and for determination of the flow rates of oil, water and gas in pipelines. The first two systems, licensed to Australian companies, are used world-wide. They are now the market leaders for radioisotope gauges in their application field. The third, the multiphase flow meter, was licensed in 1997 to an international company. This meter has even greater potential than the other two systems for economic benefit from its use and for numbers of installations. (author)

  2. Increased Cortical Thickness in Professional On-Line Gamers

    Science.gov (United States)

    Hyun, Gi Jung; Shin, Yong Wook; Kim, Bung-Nyun; Cheong, Jae Hoon; Jin, Seong Nam

    2013-01-01

    Objective The bulk of recent studies have tested whether video games change the brain in terms of activity and cortical volume. However, such studies are limited by several factors including cross-sectional comparisons, co-morbidity, and short-term follow-up periods. In the present study, we hypothesized that cognitive flexibility and the volume of brain cortex would be correlated with the career length of on-line pro-gamers. Methods High-resolution magnetic resonance scans were acquired in twenty-three pro-gamers recruited from StarCraft pro-game teams. We measured cortical thickness in each individual using FreeSurfer and the cortical thickness was correlated with the career length and the performance of the pro-gamers. Results Career length was positively correlated with cortical thickness in three brain regions: right superior frontal gyrus, right superior parietal gyrus, and right precentral gyrus. Additionally, increased cortical thickness in the prefrontal cortex was correlated with winning rates of the pro-game league. Increased cortical thickness in the prefrontal and parietal cortices was also associated with higher performance of Wisconsin Card Sorting Test. Conclusion Our results suggest that in individuals without pathologic conditions, regular, long-term playing of on-line games is associated with volume changes in the prefrontal and parietal cortices, which are associated with cognitive flexibility. PMID:24474988

  3. Utilization of microwave and ultrasound pretreatments in the production of bioethanol from corn

    Energy Technology Data Exchange (ETDEWEB)

    Nikolic, Svetlana; Mojovic, Ljiljana; Rakin, Marica [University of Belgrade, Faculty of Technology and Metallurgy, Belgrade (Serbia); Pejin, Dusanka; Pejin, Jelena [University of Novi Sad, Faculty of Technology, Novi Sad (Serbia)

    2011-08-15

    Bioethanol production by simultaneous saccharification and fermentation (SSF) of corn meal by Saccharomyces cerevisiae var. ellipsoideus yeast in a batch system with prior ultrasound or microwave treatment was studied. The optimal duration of the pretreatments and the SSF process kinetics were assessed and determined. Also, the effect of ultrasound and microwave pretreatments on ethanol yield and productivity was investigated. An optimal duration of 5 min was determined for both pretreatments. Ultrasonic and microwave pretreatments effectively increased the glucose concentration obtained after liquefaction by 6.82 and 8.48%, respectively, compared to untreated control sample. Also, both pretreatments improved ethanol yield and productivity during the SSF process. Ultrasound and microwave pretreatments increased the maximum ethanol concentration produced in the SSF process by 11.15 and 13.40% (compared to the control sample), respectively. The application of microwave pretreatment resulted in higher glucose release during liquefaction and consequently in higher ethanol concentration, compared to ultrasound pretreatment. A maximum ethanol concentration of 9.91% (w/w) and percentage of theoretical ethanol yield of 92.27% were achieved after 44 h of the SSF process of corn meal with prior microwave treatment. (orig.)

  4. General-purpose chemical analyzer for on-line analyses of radioactive solutions

    International Nuclear Information System (INIS)

    Spencer, W.A.; Kronberg, J.W.

    1983-01-01

    An automated analyzer is being developed to perform analytical measurements on radioactive solutions on-line in a hostile environment. This General Purpose Chemical Analyzer (GPCA) samples a process stream, adds reagents, measures solution absorbances or electrode potentials, and automatically calculates the results. The use of modular components, under microprocessor control, permits a single analyzer design to carry out many types of analyses. This paper discusses the more important design criteria for the GPCA, and describes the equipment being tested in a prototype unit

  5. Continuous determination of volatile products in anaerobic fermenters by on-line capillary gas chromatography

    International Nuclear Information System (INIS)

    Diamantis, V.; Melidis, P.; Aivasidis, A.

    2006-01-01

    Bio-ethanol and biogas produced during the anaerobic conversion of organic compounds has been a subject of great interest since the oil crisis of the 1970s. In ethanol fermentation and anaerobic treatment of wastewaters, end-product (ethanol) and intermediate-products (short-chain fatty acids, SCFA) cause inhibition that results in reduced process efficiency. Control of these constituents is of utmost importance for bioreactor optimization and process stability. Ethanol and SCFA can be detected with precision by capillary gas chromatography usually conducted in off-line measurements. In this work, an on-line monitoring and controlling system was developed and connected to the fermenter via an auto-sampling equipment, which could perform the feeding, filtration and dilution of the sample and final injection into the gas chromatograph through an automation-based programmed procedure. The sample was continuously pumped from the recycle stream of the bioreactor and treated using a microfiltration unit. The concentrate was returned to the reactor while the permeate was quantitatively mixed with an internal standard solution. The system comprised of a gas chromatograph with the flow cell and one-shot sampler and a PC with the appropriate software. The on-line measurement of ethanol and SCFA, directly from the liquid phase of an ethanol fermenter and a high-rate continuous mode anaerobic digester, was accomplished by gas chromatography. Also, this monitoring and controlling system was proved to be effective in the continuous fermentation of alcohol-free beer

  6. A four-detector spectrometer for e--γ PAC on-line with the ISOLDE-CERN isotope separator

    International Nuclear Information System (INIS)

    Marques, J.G.; Correia, J.G.; Melo, A.A.; Silva, M.F. da; Soares, J.C.

    1995-01-01

    A four-detector e - -γ spectrometer has been installed on-line with the ISOLDE isotope separator. The spectrometer consists of two magnetic lenses for detection of conversion electrons, and two BaF 2 scintillators for γ-ray detection. The spectrometer has been equipped with a 20 kV pre-acceleration system which enables detection of conversion electrons down to 2 keV. Implantation and measurement can be performed simultaneously on a large temperature range by heating or cooling the sample holder. The advantages of using the e - -γ PAC technique on-line at ISOLDE are discussed. (orig.)

  7. Characterisation of spent nuclear fuels by an on-line coupled HPLC-ICP-MS system

    International Nuclear Information System (INIS)

    Guenther-Leopold, I.; Gabler, F.; Wernli, B.; Kopajtic, Z.

    2000-01-01

    The determination of burn-up is one of the essential components of post-irradiation examination of nuclear fuel samples. In the framework of the ARIANE programme (Actinides Research in a Nuclear Element), at PSI the analysis of the isotopic vectors of uranium, plutonium, neodymium and some other fission and spallation products was carried out for the first time in the Hot Lab using high-performance liquid chromatography (HPLC), coupled on-line with an inductively coupled plasma mass spectrometer (ICP-MS). The results of these investigations, a comparison with the classical technique for burn-up determination, the advantages and limitations of the new method, the accuracy and precision of these types of analyses, the applicability of the technique to other samples and separation problems, and conclusions for further analyses of nuclear fuel samples, are here presented. (authors)

  8. Microextraction sample preparation techniques in biomedical analysis.

    Science.gov (United States)

    Szultka, Malgorzata; Pomastowski, Pawel; Railean-Plugaru, Viorica; Buszewski, Boguslaw

    2014-11-01

    Biologically active compounds are found in biological samples at relatively low concentration levels. The sample preparation of target compounds from biological, pharmaceutical, environmental, and food matrices is one of the most time-consuming steps in the analytical procedure. The microextraction techniques are dominant. Metabolomic studies also require application of proper analytical technique for the determination of endogenic metabolites present in biological matrix on trace concentration levels. Due to the reproducibility of data, precision, relatively low cost of the appropriate analysis, simplicity of the determination, and the possibility of direct combination of those techniques with other methods (combination types on-line and off-line), they have become the most widespread in routine determinations. Additionally, sample pretreatment procedures have to be more selective, cheap, quick, and environmentally friendly. This review summarizes the current achievements and applications of microextraction techniques. The main aim is to deal with the utilization of different types of sorbents for microextraction and emphasize the use of new synthesized sorbents as well as to bring together studies concerning the systematic approach to method development. This review is dedicated to the description of microextraction techniques and their application in biomedical analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Construction of prototype of on-line analyzer detection system for coal on belt conveyor using neutron activation technique

    International Nuclear Information System (INIS)

    Rony Djokorayono; Agus Cahyono; MP Indarzah; SG Usep; Sukandar

    2015-01-01

    The use of on-line neutron activation technique for coal analysis is proposed as an alternative method for analysis based on sampling technique. Compared to this conventional technique, the on-line neutron activation technique has much shorter time of analysis and more accurate results. The construction of detection system prototype for the on-line analyzer is described in this paper. This on-line analyzer consists of detection system, data acquisition system, and computer console. This detection system comprises several modules, i.e. NaI(Tl) scintillation detector completed with a photomultiplier tube (PMT), pre-amplifier, single channel analyzer (SCA), and analog signal transmitter and pulse counter processor. The construction processes of these four modules include the development of configuration block, lay out, and selection of electronic components. The modules have been integrated and tested. This detection system was tested using radioactive element Zn-65 having energy of 1115.5 keV and activity of 1 μCi. The test results show that the prototype of the on-line analyzer detection system has functioned as expected. (author)

  10. The effect of dilute acid pre-treatment process in bioethanol production from durian (Durio zibethinus) seeds waste

    Science.gov (United States)

    Ghazali, K. A.; Salleh, S. F.; Riayatsyah, T. M. I.; Aditiya, H. B.; Mahlia, T. M. I.

    2016-03-01

    Lignocellulosic biomass is one of the promising feedstocks for bioethanol production. The process starts from pre-treatment, hydrolysis, fermentation, distillation and finally obtaining the final product, ethanol. The efficiency of enzymatic hydrolysis of cellulosic biomass depends heavily on the effectiveness of the pre-treatment step which main function is to break the lignin structure of the biomass. This work aims to investigate the effects of dilute acid pre-treatment on the enzymatic hydrolysis of durian seeds waste to glucose and the subsequent bioethanol fermentation process. The yield of glucose from dilute acid pre-treated sample using 0.6% H2SO4 and 5% substrate concentration shows significant value of 23.4951 g/L. Combination of dilute acid pre-treatment and enzymatic hydrolysis using 150U of enzyme able to yield 50.0944 g/L of glucose content higher compared to normal pre-treated sample of 8.1093 g/L. Dilute acid pre-treatment sample also shows stable and efficient yeast activity during fermentation process with lowest glucose content at 2.9636 g/L compared to 14.7583g/L for normal pre-treated sample. Based on the result, it can be concluded that dilute acid pre-treatment increase the yield of ethanol from bioethanol production process.

  11. Method for pretreating lignocellulosic biomass

    Science.gov (United States)

    Kuzhiyil, Najeeb M.; Brown, Robert C.; Dalluge, Dustin Lee

    2015-08-18

    The present invention relates to a method for pretreating lignocellulosic biomass containing alkali and/or alkaline earth metal (AAEM). The method comprises providing a lignocellulosic biomass containing AAEM; determining the amount of the AAEM present in the lignocellulosic biomass; identifying, based on said determining, the amount of a mineral acid sufficient to completely convert the AAEM in the lignocellulosic biomass to thermally-stable, catalytically-inert salts; and treating the lignocellulosic biomass with the identified amount of the mineral acid, wherein the treated lignocellulosic biomass contains thermally-stable, catalytically inert AAEM salts.

  12. On-line determination of moisture in coal and coke

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Sowerby, B.D.

    1987-01-01

    The CSIRO Division of Mineral Engineering is developing various techniques for the on-line determination of moisture in coal and coke, and some instruments are now commercially available. These techniques permit accurate and rapid determination of moisture in materials directly on conveyor belts or in bins. The most promising techniques for direct on-belt measurement of moisture in coal are capacitance and microwave transmission. A non-contacting under-belt capacitance and gamma-ray backscatter technique has determined moisture in coal to better than 0.5 wt% in field tests. CSIRO is developing a fast neutron and gamma-ray transmission technique, which is proving very accurate in laboratory tests. This technique overcomes many of the limitations of thermal neutrons moisture gauges

  13. On-line monitoring system for utility boiler diagnostics

    International Nuclear Information System (INIS)

    Radovanovic, P.M.; Afgan, N.H.; Caralho, M.G.

    1997-01-01

    The paper deals with the new developed modular type Monitoring System for Utility Boiler Diagnostics. Each module is intended to assess the specific process and can be used as a stand alone application. Four modules are developed, namely: LTC - module for the on-line monitoring of parameters related to the life-time consumption of selected boiler components; TRD - module for the tube rupture detection by the position and working fluid Ieakage quantity; FAM - module for the boiler surfaces fouling (slagging) assessment and FLAP - module for visualization of the boiler furnace flame position. All four modules are tested on respective pilot plants built oil the 200 and 300 MWe utility boilers. Monitoring System is commercially available and can be realized in any combination of its modules depending on demands induced by the operational problems of specific boiler. Further development of Monitoring System is performed in accordance with the respective EU project on development of Boiler Expert System. (Author)

  14. On-line Certification for All: The PINVOX Algorithm

    Directory of Open Access Journals (Sweden)

    E Canessa

    2012-09-01

    Full Text Available A protoype algorithm: PINVOX (“Personal Identification Number by Voice" for on-line certification is introduced to guarantee that scholars have followed, i.e., listened and watched, a complete recorded lecture with the option of earning a certificate or diploma of completion after remotely attending courses. It is based on the injection of unique, randomly selected and pre-recorded integer numbers (or single letters or words within the audio trace of a video stream at places where silence is automatically detected. The certificate of completion or “virtual attendance” is generated on-the-fly after the successful identification of the embedded PINVOX code by a video viewer student.

  15. On-line control of the nonlinear dynamics for synchrotrons

    Science.gov (United States)

    Bengtsson, J.; Martin, I. P. S.; Rowland, J. H.; Bartolini, R.

    2015-07-01

    We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of "smart sextupole knobs" attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  16. On-line control of the nonlinear dynamics for synchrotrons

    Directory of Open Access Journals (Sweden)

    J. Bengtsson

    2015-07-01

    Full Text Available We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of “smart sextupole knobs” attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  17. On-line monitoring system for I-131 manufacturing labs

    International Nuclear Information System (INIS)

    Osovizky, A.; Malamud, Y.; Paran, Y.; Tal, N.; Turgeman, S.; Weinstein, M.

    1997-01-01

    An on-line monitoring and safety system has been installed in a lab for manufacturing 1-131 capsules for nuclear medicine use. Production of up to 100mCi batches is performed in shielded glove boxes. The safety system is based on a unique, 'Medi SMARTS' system (Medical Survey Mapping Automatic Radiation Tracing System), that collects continuously the radiation measurements for processing, display, and storage for future retrieval. Radiation is measured by GM tubes, data is transferred to a data processing unit, and then via a RS-485 communication line to a computer. In addition to the operational advantages and radiation levels storage, the system is being evaluated for the purpose of identifying risky stages in the process. (authors)

  18. Issues for Bringing Electron Beam Irradiators On-Line

    International Nuclear Information System (INIS)

    Kaye, R.J.; Turman, B.N.

    1999-01-01

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined

  19. On-line fatigue monitoring system for reactor pressure vessel

    International Nuclear Information System (INIS)

    Tokunaga, K.; Sakai, A.; Aoki, T.; Ranganath, S.; Stevens, G.L.

    1994-01-01

    A workstation-based, on-line fatigue monitoring system for tracking fatigue usage applied to an operating boiling water reactor (BWR), Tsuruga Unit-1, is described. The system uses the influence function approach and determines component stresses using temperature, pressure, and flow rate data that are made available via signal taps from previously existing plant sensors. Using plant unique influence functions developed specifically for the feedwater nozzle location, the system calculates stresses as a function of time and computed fatigue usage. The analysis method used to compute fatigue usage complies with MITI Code Notification No.501. Fatigue usage results for an entire fuel cycle are presented and compared to assumed design basis events to confirm that actual plant thermal duty is significantly less severe than originally estimated in the design basis stress report. As a result, the system provides the technical basis to more accurately evaluate actual reactor conditions as well as the justification for plant life extension. (author)

  20. On-line fatigue monitoring and probabilistic assessment of margins

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, I. [Electricite de France, 93 - Saint-Denis (France). Direction des Etudes et Recherches; Morilhat, P. [Electricite de France, 93 - Saint-Denis (France). Direction des Etudes et Recherches

    1995-01-01

    An on-line computer-aided system has been developed by Electricite de France, the French utility, for fatigue monitoring of critical locations in the nuclear steam supply system. This tool, called a fatigue meter, includes as input data plant parameters and is based on some conservative assumptions at several steps of the damage assessment (thermal boundary conditions, stress computation,..). In this paper we present recent developments performed towards a better assessment of margins involved in the complete analysis. The methodology is illustrated with an example showing the influence of uncertainty in plant parameters on the final stress computed at a pressurized water reactor 900MW unit pressurizer surge line nozzle. A second example is shown to illustrate the possibility of defining some transient archetypes. ((orig.)).

  1. On-line Monitoring of Instrumentation in Research Reactors

    International Nuclear Information System (INIS)

    2017-12-01

    This publication is the result of a benchmarking effort undertaken under the IAEA coordinated research project on improved instrumentation and control (I&C) maintenance techniques for research reactors. It lays the foundation for implementation of on-line monitoring (OLM) techniques and establishment of the validity of those for improved maintenance practices in research reactors for a number of applications such as change to condition based calibration, performance monitoring of process instrumentation systems, detection of process anomalies and to distinguish between process problems/effects and instrumentation/sensor issues. The techniques and guidance embodied in this publication will serve the research reactor community in providing the technical foundation for implementation of OLM techniques. It is intended to be used by Member States to implement I&C maintenance and to improve performance of research reactors.

  2. On-line control of nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Parus, I.; Kierzek, J.; Zoltowski, T.

    1977-01-01

    The development trends in the field of chemical processes control and the present state of the development of continuous composition analysers has been described. On this background the peculiarities of on-line control methods for spent nuclear fuel reprocessing have been discussed. The measuring methods for direct and indirect determination of chemical composition and nuclear safety are reviewed in detail. The review comprises such methods as: measurement of α, γ and neutron radiation emitted both by nuclides present in technological solutions and using external sources of different radiation, X-ray fluorescence, measurements of physicochemical parameters connected with the composition (pH, density, electrical conductivity), polarography and spectrophotometry. At the end of this review some new trends in process control based on dynamic process models have been presented. (author)

  3. The Task Manager for the LHCb On-Line Farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2004-01-01

    The Task Manager is a utility to start, stop and list processes on the on-line farm. Each process started by the Task Manager has a string environment variable set, named UTGID (User defined unique Thread Group Identifier) which allows to identify the process. The Task Manager uses the UTGID to list the running processes and to identify the processes to be stopped. It has also the ability to start a process using a particular user name and to set the scheduler type and the priority for the process itself. The Task Manager package includes a Linux DIM server (tmSrv), four Linux command line DIM clients (tmStart, tmLs, tmKill and tmStop) and a JCOP (Joint Control Project) PVSS client.

  4. On-line Corrosion Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2005-01-01

    The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress, ......, precipitation of deposits or crevices. The authors describe methods used for on-line monitoring of corrosion, cover the complications and the main results of a Nordic project.......The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress...

  5. On-line efficiency optimization of a synchronous reluctance motor

    Energy Technology Data Exchange (ETDEWEB)

    Lubin, Thierry; Razik, Hubert; Rezzoug, Abderrezak [Groupe de Recherche en Electrotechnique et Electronique de Nancy, GREEN, CNRS-UMR 7037, Universite Henri Poincare, BP 239, 54506 Vandoeuvre-les-Nancy Cedex (France)

    2007-04-15

    This paper deals with an on-line optimum-efficiency control of a synchronous reluctance motor drive. The input power minimization control is implemented with a search controller using Fibonacci search algorithm. It searches the optimal reference value of the d-axis stator current for which the input power is minimum. The input power is calculated from the measured dc-bus current and dc-bus voltage of the inverter. A rotor-oriented vector control of the synchronous reluctance machine with the optimization efficiency controller is achieved with a DSP board (TMS302C31). Experimental results are presented to validate the proposed control methods. It is shown that stability problems can appear during the search process. (author)

  6. Development of on-line monitoring system using smart material

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Kyung; Lee, Sang Pill; Park, Yi Hyun [Dongeui Univ., Busan (Korea, Republic of); Park, Young Chul [Donga Univ., Busan (Korea, Republic of)

    2003-07-01

    A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA.

  7. Development of on-line monitoring system using smart material

    International Nuclear Information System (INIS)

    Lee, Jin Kyung; Lee, Sang Pill; Park, Yi Hyun; Park, Young Chul

    2003-01-01

    A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA

  8. Issues for Bringing Electron Beam Irradiators On-Line

    Energy Technology Data Exchange (ETDEWEB)

    Kaye, R.J.; Turman, B.N.

    1999-04-20

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined.

  9. Escapist Motives for Playing On-Line Games

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    2012-01-01

    Social games have become popular along with the tremendous growth of social networking sites, esp. Facebook. There is a gap in literature on what motivates people to play Facebook games. This paper studies social games usage behavior of students. We focus on escapist reasons, based on Warmelink...... of escapist motives for playing Facebook and other on-line games, we investigate how they are linked to demographic data such as: age, gender, place of origin, along with other social interactions patterns and social network usage behavior, current gaming status and an estimate of gaming time. According...... to our study, only 10% of respondents, who have started to play Facebook games, continued to play them. The most important motives for playing games is mundane breaking, the second reason is pleasure seeking, the third is stress relieving, and the least important is imagination conjuring....

  10. Configuration Database for BaBar On-line

    International Nuclear Information System (INIS)

    Salnikov, Andrei

    2003-01-01

    The configuration database is one of the vital systems in the BaBar on-line system. It provides services for the different parts of the data acquisition system and control system, which require run-time parameters. The original design and implementation of the configuration database played a significant role in the successful BaBar operations since the beginning of experiment. Recent additions to the design of the configuration database provide better means for the management of data and add new tools to simplify main configuration tasks. We describe the design of the configuration database, its implementation with the Objectivity/DB object-oriented database, and our experience collected during the years of operation

  11. 3rd Computer Science On-line Conference

    CERN Document Server

    Senkerik, Roman; Oplatkova, Zuzana; Silhavy, Petr; Prokopova, Zdenka

    2014-01-01

    This book is based on the research papers presented in the 3rd Computer Science On-line Conference 2014 (CSOC 2014).   The conference is intended to provide an international forum for discussions on the latest high-quality research results in all areas related to Computer Science. The topics addressed are the theoretical aspects and applications of Artificial Intelligences, Computer Science, Informatics and Software Engineering.   The authors provide new approaches and methods to real-world problems, and in particular, exploratory research that describes novel approaches in their field. Particular emphasis is laid on modern trends in selected fields of interest. New algorithms or methods in a variety of fields are also presented.   This book is divided into three sections and covers topics including Artificial Intelligence, Computer Science and Software Engineering. Each section consists of new theoretical contributions and applications which can be used for the further development of knowledge of everybod...

  12. On-line Ciphers and the Hash-CBC Constructions

    DEFF Research Database (Denmark)

    Bellare, M.; Boldyreva, A.; Knudsen, Lars Ramkilde

    2012-01-01

    We initiate a study of on-line ciphers. These are ciphers that can take input plaintexts of large and varying lengths and will output the i th block of the ciphertext after having processed only the first i blocks of the plaintext. Such ciphers permit length-preserving encryption of a data stream...... with only a single pass through the data. We provide security definitions for this primitive and study its basic properties. We then provide attacks on some possible candidates, including CBC with fixed IV. We then provide two constructions, HCBC1 and HCBC2, based on a given block cipher E and a family...... of computationally AXU functions. HCBC1 is proven secure against chosen-plaintext attacks assuming that E is a PRP secure against chosen-plaintext attacks, while HCBC2 is proven secure against chosen-ciphertext attacks assuming that E is a PRP secure against chosen-ciphertext attacks....

  13. On-line defected fuel monitoring using GFP data

    International Nuclear Information System (INIS)

    Livingstone, S.; Lewis, B.J.

    2008-01-01

    This paper describes the initial development of an on-line defected fuel diagnostic tool. The tool is based on coolant activity, and uses a quantitative and qualitative approach from existing mechanistic fission product release models, and also empirical rules based on commercial and experimental experience. The model departs from the usual methodology of analyzing steady-state fission product coolant activities, and instead uses steady-state fission product release rates calculated from the transient coolant activity data. An example of real-time defected fuel analysis work is presented using a prototype of this tool with station data. The model is in an early developmental stage, and this paper demonstrates the promising potential of this technique. (author)

  14. An on-line advanced plant simulator (OLAPS)

    International Nuclear Information System (INIS)

    Samuels, J.W.

    1989-01-01

    A PC based on-line advanced plant simulator (OLAPS) for high quality simulations of Portland General Electric's Trojan Nuclear Facility is presented. OLAPS is designed to simulate the thermal-hydraulics of the primary system including core, steam generators, pumps, piping and pressurizer. The simulations are based on a five equation model that has two mass equations, two energy equations, two energy equations, and one momentum equation with a drift flux model to provide closure. A regionwise point reactor kinetics model is used to model the neutron kinetics in the core. The conservation equations, constitutive models and the numerical methods used to solve them are described. OLAPS results are compared with data from chapter 15 of the Trojan Nuclear Facility's final safety analysis report

  15. The Monitor System for the LHCb on-line farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2005-01-01

    The aim of the LHCb on-line farm Monitor System is to keep under control all the working indicators which are relevant for the farm operation, and to set the appropriate alarms whenever an error or a critical condition comes up. Since the most stressing tasks of the farm are the data transfer and processing, relevant indicators includes the CPU and the memory load of the system, the network interface and the TCP/IP stack parameters, the rates of the interrupts raised by the network interface card and the detailed status of the running processes. The monitoring of computers’ physical conditions (temperatures, fan speeds and motherboard voltages) are the subject of a separate technical note, since they are accessed in a different way, by using the IPMI protocol.

  16. On-line monitoring of main coolant pump seals

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; Glass, S.W.; Sommerfield, G.A.; Harrison, D.

    1984-06-01

    The Babcock and Wilcox Company has developed and implemented a Reactor Coolant Pump Monitoring and Diagnostic System (RCPM and DS). The system has been installed at Toledo Edison Company's Davis-Besse Nuclear Power Station Unit 1. The RCPM and PS continuously monitors a number of indicators of pump performance and notifies the plant operator of out-of-tolerance conditions or pump performance trending toward out-of-tolerance conditions. Pump seal parameters being monitored include pump internal pressures, temperatures, and flow rates. Rotordynamic performanvce and plant operating conditions are also measured with a variety of dynamic sensors. This paper describes the implementation of the system and the results of on-line monitoring of four RC pumps

  17. PHEBUS on-line aerosol monitor development test program

    International Nuclear Information System (INIS)

    Sprenger, M.H.; Pentecost, C.G.

    1992-03-01

    EG ampersand G Idaho, Inc. developed an on-line aerosol monitor (OLAM) for the French PHEBUS Fission Product Project. Part of the development was to manufacture and test an OLAM prototype. This report presents the results of the testing which determined the mechanical integrity of the monitor at operating temperature and pressure and performed a preliminary test of the optical system. A series of twenty different tests was conducted during the prototype testing sequence. Since no leaks were detected, the OLAM demonstrated that it could provide a pressure boundary at required test conditions. The optical and electrical system also proved its integrity by exceeding the design requirement of less than 105 optical signal drift during an actual two-hour test sequence

  18. On line isotopic separator test benches at GANIL

    International Nuclear Information System (INIS)

    Anne, R.; Bru, B.; Joubert, A.; Leroy, R.; Obert, J.; Putaux, J.C.; Liang, C.F.; Paris, P.; Orr, N.; Steckmeyer, J.C.

    1993-01-01

    A first version of isotopic separator on line test bench has been built in order to test the feasibility of the production of radioactive species from 96 MeV/u of 20 Ne impinging a thick target of MgO. This test bench was equipped with a very compact ECR ion source (Nanogan) entirely made from permanent magnets and operating at 10 Ghz. 18 Ne 2,4+ ; 19N e 1,2,3,4+ and 23,24 Ne 1+ has been produced and ionized. A new more performing separator (SIRa) allowing the use of different types of ion sources will be completed by the end of 1993. (author) 4 refs., 4 figs., 1 tab

  19. On-line coupling of a microelectrode array equipped poly(dimethylsiloxane) microchip with an integrated graphite electrospray emitter for electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Liljegren, Gustav; Dahlin, Andreas; Zettersten, Camilla; Bergquist, Jonas; Nyholm, Leif

    2005-10-01

    A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane)(PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 microL min(-1), respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 microL min(-1). To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.

  20. PHENIX On-Line Distributed Computing System Architecture

    International Nuclear Information System (INIS)

    Desmond, Edmond; Haggerty, John; Kehayias, Hyon Joo; Purschke, Martin L.; Witzig, Chris; Kozlowski, Thomas

    1997-01-01

    PHENIX is one of the two large experiments at the Relativistic Heavy Ion Collider (RHIC) currently under construction at Brookhaven National Laboratory. The detector consists of 11 sub-detectors, that are further subdivided into 29 units (''granules'') that can be operated independently, which includes simultaneous data taking with independent data streams and independent triggers. The detector has 250,000 channels and is read out by front end modules, where the data is buffered in a pipeline while awaiting the level trigger decision. Zero suppression and calibration is done after the level accept in custom built data collection modules (DCMs) with DSPs before the data is sent to an event builder (design throughput of 2 Gb/sec) and higher level triggers. The On-line Computing Systems Group (ONCS) has two responsibilities. Firstly it is responsible for receiving the data from the event builder, routing it through a network of workstations to consumer processes and archiving it at a data rate of 20 MB/sec. Secondly it is also responsible for the overall configuration, control and operation of the detector and data acquisition chain, which comprises the software integration for several thousand custom built hardware modules. The software must furthermore support the independent operation of the above mentioned granules, which includes the coordination of processes that run in 60-100 VME processors and workstations. ONOS has adapted the Shlaer- Mellor Object Oriented Methodology for the design of the top layer software. CORBA is used as communication layer between the distributed objects, which are implemented as asynchronous finite state machines. We will give an overview of the PHENIX online system with the main focus on the system architecture, software components and integration tasks of the On-line Computing group ONCS and report on the status of the current prototypes

  1. Progress and performance of on-line analyzers of coal

    International Nuclear Information System (INIS)

    Spencer, C.M.; Brown, D.R.; Gozani, T.; Bozorgmanesh, H.; Bernatowicz, H.; Tassicker, O.J.; Karlson, F.

    1982-01-01

    This paper describes the past year's progress in the laboratory testing of the most comprehensive Nucoalyzer, the CONAC, and the performance of a Nucoalyzer-Sulfurmeter in special field tests. Previous papers and presentations provide more detailed background information. The near real-time analysis provided by a Nucoalyzer can be used in a variety of strategies to optimize efficiency of coal use. Nucoalyzers can be used to monitor coal deliveries and achieve uniformity in coal storage and recovery. In a coal cleaning plant, on-line analysis with a Nucoalyzer can lead to optimum Btu recovery while meeting specifications for the washed coal. A Nucoalyzer can monitor the blending of different coals to maintain a key cosntituent such as sulfur below a specified level, or can predict sulfur dioxide emissions, allowing feed-forward control to gas scrubbers and precipitators. Variability in coal feed to the boiler can lead to gross changes in thermodynamic efficiency in combustion. In addition, fouling and slagging incidents due to poor coal quality cause costly boiler shutdowns and maintenance. Nucoalyzer monitoring of key constituents and Btu in the coal feed allows operators to adjust boiler parameters for increased efficiency. To summarize, the primary advantages of Nucoalyzers relate to their ability to quickly identify changes in coal composition so that adjustments can be made in a timely manner to accommodate these changes in the process being monitored. Nucoalyzers are the only instruments available that can monitor the coal (for ash, Btu, sulfur, etc.) on-line and provide real-time continuous results. One Nucoalyzer is already working in the field, and by the time of the next Symposium we will have had performance reports on two more

  2. On-line chemical sensors for applications in fast reactors

    International Nuclear Information System (INIS)

    Jayaraman, V.

    2015-01-01

    Hydrogen sensors are essential components of fast reactor sodium circuits. These sensors are needed in fast reactors for the immediate detection of any steam leak into sodium during reactor operation which can lead to failure of steam generator. Depending on the operating power of the reactor, sodium-water reaction results in either an increase in dissolved hydrogen level in sodium or an increase in hydrogen content of argon cover gas used above sodium coolant. Hence, on-line monitoring of hydrogen continuously in sodium and cover circuits helps in detection of any steam leak. In the event of accidental leak of high temperature sodium, it reacts with oxygen and moisture in air leading to sodium fires. These fires produce sodium aerosol containing oxides of sodium (Na 2 O and Na 2 O 2 ) and NaOH. For early detection of sodium fires, sensor systems based on sodium ionization detector, pH measurement and modulation of conductivity of graphite films are known in the literature. This presentation deals with the development of on-line sensors for these two applications. A diffusion based sensor using a thin walled nickel coil at 773 K and a sensitive thermal conductivity detector (TCD) has been developed for monitoring hydrogen levels in argon cover gas. This sensor has a lower detection limit of 30 ppm of hydrogen in argon. To extend the detection limit of the sensor, a surface conductivity based sensor has been developed which makes use of a thin film of semi-conducting tin oxide. Integration of this sensor with the TCD, can extend the lower detection limit to 2 ppm of hydrogen in cover gas. Electrochemical sensor based on sodium-beta-alumina has been designed, fabricated and its performance in laboratory and industrial environment was evaluated. This paper presents the logical development of these sensors highlighting their merits and limitations

  3. Combining Teletherapy and On-line Language Exercises in the Treatment of Chronic Aphasia: An Outcome Study

    Directory of Open Access Journals (Sweden)

    Richard D. Steele

    2015-01-01

    Full Text Available We report a 12-week outcome study in which nine persons with long-term chronic aphasia received individual and group speech-language teletherapy services, and also used on-line language exercises to practice from home between therapy sessions.  Participants were assessed at study initiation and completion using the Western Aphasia Battery, a portion of the Communicative Effectiveness Index, ASHA National Outcome Measurement System, and RIC Communication Confidence Rating Scale for Aphasia; additionally participants were polled regarding satisfaction at discharge.  Pre-treatment and post-treatment means were calculated and compared, and matched t-tests were used to determine significance of improvements following treatment, with patterns of independent on-line activity analyzed.  Analysis of scores shows that means improved on most measures following treatment, generally significantly: the WAB AQ improved +3.5 (p = .057; the CETI Overall (of items administered — +17.8 (p = .01, and CCRSA Overall — + 10.4 (p = .0004.  Independent work increased with time, and user satisfaction following participation was high.

  4. Impacts of operating parameters on oxidation-reduction potential and pretreatment efficacy in the pretreatment of printing and dyeing wastewater by Fenton process

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Huifang, E-mail: whfkhl@sina.com [College of Environment, Jiangsu Key Laboratory of Industrial Water-Conservation and Emission Reduction, Nanjing University of Technology, Nanjing 210009 (China); Wang, Shihe [Department of Municipal Engineering, Southeast University, Nanjing 210096 (China)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer A real printing and dyeing wastewater was pretreated by Fenton process. Black-Right-Pointing-Pointer We investigated impacts of operating parameters on ORP and pretreatment efficacy. Black-Right-Pointing-Pointer Relationship among ORP, operating parameters and treatment efficacy was established. Black-Right-Pointing-Pointer Pretreatment efficacy was in proportion to the exponent of temperature reciprocal. Black-Right-Pointing-Pointer We investigated kinetics of color and COD removal and BOD{sub 5}/COD ratio in solution. - Abstract: An experiment was conducted in a batch reactor for a real printing and dyeing wastewater pretreatment using Fenton process in this study. The results showed that original pH, hydrogen peroxide concentration and ferrous sulfate concentration affected ORP value and pretreatment efficacy greatly. Under experimental conditions, the optimal original pH was 6.61, and the optimal hydrogen peroxide and ferrous sulfate concentrations were 1.50 and 0.75 g L{sup -1}, respectively. The relationship among ORP, original pH, hydrogen peroxide concentration, ferrous sulfate concentration, and color (COD or BOD{sub 5}/COD) was established, which would be instructive in on-line monitoring and control of Fenton process using ORP. In addition, the effects of wastewater temperature and oxidation time on pretreatment efficacy were also investigated. With an increase of temperature, color and COD removal efficiencies and BOD{sub 5}/COD ratio increased, and they were in proportion to the exponent of temperature reciprocal. Similarly, color and COD removal efficiencies increased with increasing oxidation time, and both color and COD removal obeyed the first-order kinetics. The BOD{sub 5}/COD ratio could be expressed by a second-degree polynomial with respect to oxidation time, and the best biodegradability of wastewater was present at the oxidation time of 6.10 h.

  5. Impacts of operating parameters on oxidation–reduction potential and pretreatment efficacy in the pretreatment of printing and dyeing wastewater by Fenton process

    International Nuclear Information System (INIS)

    Wu, Huifang; Wang, Shihe

    2012-01-01

    Highlights: ► A real printing and dyeing wastewater was pretreated by Fenton process. ► We investigated impacts of operating parameters on ORP and pretreatment efficacy. ► Relationship among ORP, operating parameters and treatment efficacy was established. ► Pretreatment efficacy was in proportion to the exponent of temperature reciprocal. ► We investigated kinetics of color and COD removal and BOD 5 /COD ratio in solution. - Abstract: An experiment was conducted in a batch reactor for a real printing and dyeing wastewater pretreatment using Fenton process in this study. The results showed that original pH, hydrogen peroxide concentration and ferrous sulfate concentration affected ORP value and pretreatment efficacy greatly. Under experimental conditions, the optimal original pH was 6.61, and the optimal hydrogen peroxide and ferrous sulfate concentrations were 1.50 and 0.75 g L −1 , respectively. The relationship among ORP, original pH, hydrogen peroxide concentration, ferrous sulfate concentration, and color (COD or BOD 5 /COD) was established, which would be instructive in on-line monitoring and control of Fenton process using ORP. In addition, the effects of wastewater temperature and oxidation time on pretreatment efficacy were also investigated. With an increase of temperature, color and COD removal efficiencies and BOD 5 /COD ratio increased, and they were in proportion to the exponent of temperature reciprocal. Similarly, color and COD removal efficiencies increased with increasing oxidation time, and both color and COD removal obeyed the first-order kinetics. The BOD 5 /COD ratio could be expressed by a second-degree polynomial with respect to oxidation time, and the best biodegradability of wastewater was present at the oxidation time of 6.10 h.

  6. Corrosion resistance of biomimetic calcium phosphate coatings on magnesium due to varying pretreatment time

    Energy Technology Data Exchange (ETDEWEB)

    Waterman, J., E-mail: jay.waterman@pg.canterbury.ac.nz [Department of Mechanical Engineering, University of Canterbury, Christchurch (New Zealand); Pietak, A. [Department of Anatomy and Structural Biology, University of Otago, Dunedin (New Zealand); Birbilis, N. [Department of Materials Engineering, Monash University (Australia); Woodfield, T. [Department of Mechanical Engineering, University of Canterbury, Christchurch (New Zealand); Department of Orthopaedic Surgery, University of Otago, Christchurch (New Zealand); Dias, G. [Department of Anatomy and Structural Biology, University of Otago, Dunedin (New Zealand); Staiger, M.P., E-mail: mark.staiger@canterbury.ac.nz [Department of Mechanical Engineering, University of Canterbury, Christchurch (New Zealand)

    2011-12-15

    Calcium phosphate coatings were prepared on magnesium substrates via a biomimetic coating process. The effects of a magnesium hydroxide pretreatment on the formation and the ultimate corrosion protection of the coatings were studied. The pretreatment layer was found to affect the amount of defects present in the coatings. Corrosion resistance of the coatings was studied in vitro using two simulated body fluids, 0.8% NaCl and Hanks solution. In NaCl, the resistance to corrosion of all samples decreases with time as corrosion proceeded through cracks and other defects in the coatings. Samples with no pretreatment displayed the highest corrosion resistance as these samples had the fewest defects in the coating. However, in Hanks solution, corrosion resistance increased with time due to additional nucleation of calcium phosphate from the fluid on to the substrate. In this solution, additional pretreatment time was beneficial to the overall corrosion resistance.

  7. Combined Mechanical Destruction and Alkaline Pretreatment of Wheat Straw for Enhanced Enzymatic Saccharification

    Directory of Open Access Journals (Sweden)

    Qianqian Wang

    2014-09-01

    Full Text Available Wheat straw was pretreated by combined mechanical destruction and alkaline pretreatments to enhance enzymatic saccharification. Four strategies were employed to evaluate the potential of wheat straw as a feedstock for fermentable sugar production. The effects of the pretreatments on the substrate morphology, size distribution, chemical composition, and cellulose crystallinity, along with the subsequent enzymatic digestibility, were investigated. Optical microscope images showed that mechanical pretreatment alone resulted in poor fiber defibrillation, wherein samples mostly consisted of rigid fiber bundles, while integrated mechanical destruction and alkaline pretreatment led to relatively good fiber defibrillation. Low temperature NaOH/urea pretreatment can fibrillate the rigid fiber bundles into a relatively loose network and alter the structure of the treated substrate to make cellulose more accessible. The glucan conversion rates were 77% and 95% for integrated mechanical destruction and alkaline pretreatments and mechanical destruction followed by low temperature NaOH/urea and ammonium/urea pretreatments, respectively, after 72 h of enzymatic hydrolysis with enzyme loadings of 10 FPU cellulase per g of oven-dry substrate.

  8. On-line coupled LC-LC-GC for irradiation detection in complex lipid matrices

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Helle, N.; Boegl, K.W.; Schreiber, G.A.

    1993-01-01

    Since sample preparation with HPLC coupled on-line to the GC has been performed for only a few weeks in our laboratory, the results presented give a first look at what can be done by means of this technique. Even difficult samples as the described fish species, where an unequivocal identification regarding an irradiation treatment seemed to become a hopeless enterprise, could be managed. Because of the greater variety of fatty acids in fish ''new'' radiation-induced hydrocarbons were available. According to the theory of Nawar in addition to 16:2 and 17:2 hydrocarbons we have looked for in irradiated meat, further alkadienes appeared in irradiated fish, which were 14:2, 18:2 and 20:2. Analysis of the alkadiene-fraction, transferred to the GC after a two step LC clean up, resulted in an unequivocal identification of all fish samples as well as the fruits and sponge cake. For fruits and sponge cake the detection limit seems to be clearly below 0.5 kGy. It can further be lowered by increasing the amount of lipid whereas the upper limit for a certain LC column has to be determined. In contrast to these samples only qualitative results were obtained for fish. In the case of sponge cake for the first time irradiation of a component of a heat treated food was detected. Further investigations regarding reproducibility, dose dependence and detection limit have to be done. On-line coupled (LC-)LC-GC was proved to be a highly efficient method for analysis of complex samples. In contrast to off-line Florisil column chromatography only a small part of the initial lipid material is needed because the complete hydrocarbon fraction is transferred on-line to the GC. This offers the possibility to analyze even foods with a low fat content like various seafoods. Classification of the hydrocarbon fraction by a two step LC may facilitate the identification of the radiolytic products also if no mass spectrometric detection system is available. (orig./vhe)

  9. The activity-integrated method for quality assessment of reduning injection by on-line DPPH-CE-DAD.

    Directory of Open Access Journals (Sweden)

    Yan-xu Chang

    Full Text Available A sensitive on-line DPPH-CE-DAD method was developed and validated for both screening and determining the concentration of seven antioxidants of Reduning injection. The pH and concentrations of buffer solution, SDS, β-CD and organic modifier were studied for the detection of DPPH and seven antioxidants. By on-line mixing DPPH and sample solution, a DPPH-CE method for testing the antioxidant activity of the complex matrix was successfully established and used to screen the antioxidant components of Reduning injection. Then, antioxidant components including caffeic acid, isochlorogenic acid A, isochlorogenic acid B, isochlorogenic acid C, chlorogenic acid, neochlorogenic acid and cryptochlorogenic acid were quantified by the newly established CE-DAD method. Finally, the total antioxidant activity and the multiple active components were selected as markers to evaluate the quality of Reduning injection. The results demonstrated that the on-line DPPH-CE-DAD method was reagent-saving, rapid and feasible for on-line simultaneous determination of total pharmacological activity and contents of multi-components samples. It was also a powerful method for evaluating the quality control and mechanism of action of TCM injection.

  10. Development of an on-line analyzer for organic phase uranium concentration in extraction process

    International Nuclear Information System (INIS)

    Dong Yanwu; Song Yufen; Zhu Yaokun; Cong Peiyuan; Cui Songru

    1998-10-01

    The working principle, constitution, performance of an on-line analyzer and the development characteristic of immersion sonde, data processing system and examination standard are reported. The performance of this instrument is reliable. For identical sample, the signal fluctuation in continuous monitoring for four months is less than +-1%. According to required measurement range by choosing appropriate length of sample cell the precision of measurement is better than 1% at uranium concentration 100 g/L. The detection limit is (50 +- 10) mg/L. The uranium concentration in process stream can be automatically displayed and printed out in real time and 4∼20 mA current signal being proportional to the uranium concentration can be presented. So the continuous control and computer management for the extraction process can be achieved

  11. Development and application of model RAIA uranium on-line analyser

    International Nuclear Information System (INIS)

    Dong Yanwu; Song Yufen; Zhu Yaokun; Cong Peiyuan; Cui Songru

    1999-01-01

    The working principle, structure, adjustment and application of model RAIA on-line analyser are reported. The performance of this instrument is reliable. For identical sample, the signal fluctuation in continuous monitoring for four months is less than +-1%. According to required measurement range, appropriate length of sample cell is chosen. The precision of measurement process is better than 1% at 100 g/L U. The detection limit is 50 mg/L. The uranium concentration in process stream can be displayed automatically and printed at any time. It presents 4∼20 mA current signal being proportional to the uranium concentration. This makes a long step towards process continuous control and computer management

  12. On-line database of the spectral properties of polycyclic aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Malloci, Giuliano; Joblin, Christine; Mulas, Giacomo

    2007-01-01

    We present an on-line database of computed molecular properties for a large sample of polycyclic aromatic hydrocarbons in four charge states: -1, 0, +1, and +2. At present our database includes 40 molecules ranging in size from naphthalene and azulene (C 10 H 8 ) up to circumovalene (C 66 H 20 ). We performed our calculations in the framework of the density functional theory (DFT) and the time-dependent DFT to obtain the most relevant molecular parameters needed for astrophysical applications. For each molecule in the sample, our database presents in a uniform way the energetic, rotational, vibrational, and electronic properties. It is freely accessible on the web at (http://astrochemistry.ca.astro.it/database/) and (http://www.cesr.fr/~joblin/database/)

  13. Sample pretretment in microsystems

    DEFF Research Database (Denmark)

    Perch-Nielsen, Ivan R.

    2003-01-01

    : Sample preparation → DNA amplification → DNA analysis. The overall goal of the project is integration of as many as possible of these steps. This thesis covers mainly pretreatment in a microchip. Some methods for sample pretreatment have been tested. Most conventional is fluorescence activated cell sort......When a sample, e.g. from a patient, is processed using conventional methods, the sample must be transported to the laboratory where it is analyzed, after which the results is sent back. By integrating the separate steps of the analysis in a micro total analysis system (μTAS), results can...... be obtained fast and better. Preferably with all the processes from sample to signal moved to the bedside of the patient. Of course there is still much to learn and study in the process of miniaturization. DNA analysis is one process subject to integration. There are roughly three steps in a DNA analysis...

  14. Sequential injection-bead injection-lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Wang Jianhua; Hansen, Elo Harald; Miro, Manuel

    2003-01-01

    This communication presents an overview of the state-of-the-art of the exploitation of sequential injection (SI)-bead injection (BI)-lab-on-valve (LOV) schemes for automatic on-line sample pre-treatments interfaced with ETAAS and ICPMS detection as conducted in the authors' group. The discussions are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material, that is, the hydrophilic SP Sephadex C-25 cation exchange and iminodiacetate based Muromac A-1 chelating resins, and the hydrophobic poly(tetrafluoroethylene) (PTFE) and poly(styrene-divinylbenzene) copolymer alkylated with octadecyl groups (C 18 -PS/DVB). Using ETAAS as detection device, the easy-to-handle hydrophilic renewable reactors hold the features of improved R.S.D.s and LODs as compared to those operated in the conventional, permanent mode, in addition to the elimination of flow resistance. The hydrophobic columns fall into two categories, that is, the renewable one packed with C 18 -PS/DVB beads entails analogous R.S.D.s and LODs with respect to the conventional approach, while those with PTFE beads result in slightly inferior R.S.D.s and LODs by similar comparison, yet offering a wider dynamic range than when using an external permanent column. Moreover, the hydrophilic materials result in much higher enrichment of the analyte than the hydrophobic ones, although PTFE is the packing material that exhibits the best retention efficiency

  15. Optimized convective transport with automated pressure control in on-line postdilution hemodiafiltration.

    Science.gov (United States)

    Joyeux, V; Sijpkens, Y; Haddj-Elmrabet, A; Bijvoet, A J; Nilsson, L-G

    2008-11-01

    In a stable patient population we evaluated on-line postdilution hemodiafiltration (HDF) on the incremental improvement in blood purification versus high-flux HD, using the same dialyzer and blood flow rate. For HDF we used a new way of controlling HDF treatments based on the concept of constant pressure control where the trans-membrane pressure is automatically set by the machine using a feedback loop on the achieved filtration (HDF UC). We enrolled 20 patients on on-line HDF treatment and during a 4-week study period recorded key treatment parameters in HDF UC. For one mid-week study treatment performed in HD and one midweek HDF UC treatment we sampled blood and spent dialysate to evaluate the removal of small- and middle-sized solutes. We achieved 18+/-3 liters of ultrafiltration in four-hour HDF UC treatments, corresponding to 27+/-3% of the treated blood volume. That percentage varied by patient hematocrit level. The ultrafiltration amounted to 49+/-4% of the estimated plasma water volume treated. We noted few machine alarms. For beta2m and factor D the effective reduction in plasma level by HDF (76+/-6% and 43+/-9%, respectively) was significantly greater than in HD, and a similar relation was seen in mass recovered in spent dialysate. Small solute removal was similar in HDF and HD. Albumin loss was low. The additional convective transport provided by on-line HDF significantly improved the removal of middle molecules when all other treatment settings were equal. Using the automated pressure control mode in HDF, the convective volume depended on the blood volume processed and the patient hematocrit level.

  16. Monitoring and control of enzymic sucrose hydrolysis using on-line biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Mandenius, C F; Buelow, L; Danielsson, B; Mosbach, K

    1985-02-01

    Previously reported flow microcalorimeter devices for enzymic reaction heat measurement, enzyme thermistors, have here been extended with systems for on-line sample treatment. Glucose analysis was performed by intermittent flow injection of 50 ..mu..l samples through such an enzyme thermistor device containing immobilized glucose oxidase and catalase. Sucrose analysis was performed by allowing diluted samples to continuously pass through an additional enzyme thermistor containing immobilized invertase. The reaction heats were recorded as temperature changes in the order of 10-50 m degrees C for concentration of 0.05-0.30 M glucose or sucrose present in the original non-diluted samples. The performance of this system was investigated by its ability to follow concentration changes obtained from a gradient mixer. The system was applied to monitoring and controlling the hydrolysis of sucrose to glucose and fructose in a plug-flow reactor with immobilized invertase. The reactor was continuously fed by a flow of sucrose of up to 0.3 M (100 g/l). Glucose and remaining sucrose were monitored in the effluent of the column. By using flow rate controlled feed pumps for sucrose and diluent the influent concentration of sucrose was varied while the overall flow rate remained constant. On-line control of the effluent concentration of glucose and sucrose was achieved by a proportional and integral regulator implemented on a microcomputer. Present concentration of glucose in the effluent could be maintained over an extended period of time despite changes in the overall capacity of the invertase reactor. Long delay times in the sensor system and the enzyme column made it necessary to carefully tune the control parameters. Changes of set-point value and temperature disturbances were used to verify accuracy of controlling performance. 32 references.

  17. On-line electrochemical monitoring of microbially influenced corrosion

    International Nuclear Information System (INIS)

    Dowling, N.J.E.; Stansbury, E.E.; White, D.C.; Borenstein, S.W.; Danko, J.C.

    1989-01-01

    Newly emerging electrochemical measurement techniques can provide on-line, non-destructive monitoring of the average corrosion rate and indications of localized pitting corrosion together with insight into fundamental electrochemical mechanisms responsible for the corrosion process. This information is relevant to evaluating, monitoring, understanding and controlling microbially influenced corrosion (MIC). MIC of coupons exposed in sidestream devices on site or in laboratory-based experiments, where the corrosion response is accelerated by exposure to active consortia of microbes recovered from specific sites, can be utilized to evaluate mitigation strategies. The average corrosion rates can be determined by small amplitude cyclic voltametry (SACV), and AC impedance spectroscopy (EIS). EIS can also give insight into the mechanisms of the MIC and indications of localized corrosion. Pitting corrosion can be detected non-destructively with open circuit potential monitoring (OCP). OCP also responds to bacterial biofilm activities such as oxygen depletion and other electrochemical activities. Utilizing these methods, accelerated tests can be designed to direct the selection of materials, surface treatments of materials, and welding filler materials, as well as the optimization of chemical and mechanical countermeasures with the microbial consortia recovered and characterized from the specific sites of interest

  18. Virtual laboratories: Collaborative environments and facilities-on-line

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, C.E. Jr. [Oak Ridge National Lab., TN (United States). I and C Div.; Cavallini, J.S.; Seweryniak, G.R.; Kitchens, T.A.; Hitchcock, D.A.; Scott, M.A.; Welch, L.C. [Dept. of Energy, Germantown, MD (United States). Mathematical Information, and Computational Sciences Div.; Aiken, R.J. [Dept. of Energy, Germantown, MD (United States). Mathematical Information, and Computational Sciences Div.]|[Lawrence Livermore National Lab., CA (United States); Stevens, R.L. [Argonne National Lab., IL (United States). Mathematics and Computer Sciences Div.

    1995-07-01

    The Department of Energy (DOE) has major research laboratories in a number of locations in the US, typically co-located with large research instruments or research facilities valued at tens of millions to even billions of dollars. Present budget exigencies facing the entire nation are felt very deeply at DOE, just as elsewhere. Advances over the last few years in networking and computing technologies make virtual collaborative environments and conduct of experiments over the internetwork structure a possibility. The authors believe that development of these collaborative environments and facilities-on-line could lead to a ``virtual laboratory`` with tremendous potential for decreasing the costs of research and increasing the productivity of their capital investment in research facilities. The majority of these cost savings would be due to increased productivity of their research efforts, better utilization of resources and facilities, and avoiding duplication of expensive facilities. A vision of how this might all fit together and a discussion of the infrastructure necessary to enable these developments is presented.

  19. The on-line low temperature nuclear orientation facility NICOLE

    International Nuclear Information System (INIS)

    Ohtsubo, T; Roccia, S; Gaulard, C; Stone, N J; Stone, J R; Köster, U; Nikolov, J; Veskovic, M; Simpson, G S

    2017-01-01

    We review major experiments and results obtained by the on-line low temperature nuclear orientation method at the NICOLE facility at ISOLDE, CERN since the year 2000 and highlight their general physical impact. This versatile facility, providing a large degree of controlled nuclear polarization, was used for a long-standing study of magnetic moments at shell closures in the region Z  = 28, N  = 28–50 but also for dedicated studies in the deformed region around A  ∼ 180. Another physics program was conducted to test symmetry in the weak sector and constrain weak coupling beyond V–A . Those two programs were supported by careful measurements of the involved solid state physics parameters to attain the full sensitivity of the technique and provide interesting interdisciplinary results. Future plans for this facility include the challenging idea of measuring the beta–gamma–neutron angular distributions from polarized beta delayed neutron emitters, further test of fundamental symmetries and obtaining nuclear structure data used in medical applications. The facility will also continue to contribute to both the nuclear structure and fundamental symmetry test programs. (paper)

  20. The Westinghouse BEACON on-line core monitoring system

    International Nuclear Information System (INIS)

    Buechel, Robert J.; Boyd, William A.; Casadei, Alberto L.

    1995-01-01

    BEACON (Best Estimate Analysis of Core Operations - Nuclear), a core monitoring and operational support package developed by Westinghouse, has been installed at many operating PWRs worldwide. The BEACON system is a real-time monitoring system which can be used in plants with both fixed and movable incore detector systems and utilizes an on-line nodal model combined with core instrumentation data to provide continuous core power distribution monitoring. In addition, accurate core-predictive capabilities utilizing a full core nodal model updated according to plant operating history can be made to provide operational support. Core history information is kept and displayed to help operators anticipate core behavior and take pro-active control actions. The BEACON system has been licensed by the U.S. Nuclear Regulatory Commission for direct, continuous monitoring of DNBR and peak linear heat rate. This allows BEACON to be integrated into the plant technical specifications to permit significant relaxation of operating limitations defined by conventional technical specifications. (author). 4 refs, 2 figs, 1 tab

  1. Development of an On-Line Uranium Enrichment Monitor

    International Nuclear Information System (INIS)

    Xuesheng, L.; Guorong, L.; Yonggang, Z.; Xueyuan, H. X.-Y.

    2015-01-01

    An on-line enrichment monitor was developed to measure the enrichment of UF6 flowing through the processing pipes in centrifuge uranium enrichment plant. A NaI(Tl) detector was used to measure the count rates of the 186 keV gamma ray emitted from 235U, and the total quantity of uranium was determined from thermodynamic characteristics of gaseous uranium hexafluoride. The results show that the maximum relative standard deviation is less than 1% when the measurement time is 120 s or more and the pressure is more than 2 kPa in the measurement chamber. There are two working models for the monitor. The monitor works normally in the continuous model, When the gas's pressure in the pipe fluctuates greatly, it can work in the intermittent model, and the measurement result is very well. The background of the monitor can be measured automatically periodically. It can control automatically electromagnetic valves open and close, so as to change the gas's quantity in the chamber. It is a kind of unattended and remote monitor, all of data can be transfer to central control room. It should be effective for nuclear materials accountability verifications and materials balance verification at uranium enrichment plant by using the monitor to monitor Uranium enrichment of gaseous uranium hexafluoride in the output end of cascade continuously. (author)

  2. On-line mass separator of superheavy atoms

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.

    2002-01-01

    The concept is presented of an on-line Mass Analyzer of SuperHeavy Atoms (MASHA) dedicated to the separation and determination of the mass and decay properties of new elements and isotopes produced in heavy-ion induced reactions. The new nuclides with half-lives T 1/2 ≥ 1 s are transported to an ECR-source working at a frequency of 2.45 GHz and are separated by mass with a mass resolution of M/ΔM ∼ 1500. In the focal plane of the magnetic analyzer a front strip detector surrounded by side detectors will be placed to determine the mass according to the signals from the detected α-particles or fission fragments with efficiency of about 90 %. In comparison to other existing in-flight recoil separators, the present setup will be characterized by higher efficiency and high selectivity relative to background reaction products. The setup MASHA may be used also in the investigation of nuclear reactions of different type induced by stable and radioactive beams

  3. On-Line Mass Separator of Superheavy Atoms

    CERN Document Server

    Oganessian, Yu T

    2002-01-01

    The concept is presented of an on-line Mass Analyzer of SuperHeavy Atoms (MASHA) dedicated to the separation and determination of the mass and decay properties of new elements and isotopes produced in heavy-ion induced reactions. The new nuclides with half-lives T_{1/2}\\ge 1 s are transported to an ECR-source working at a frequency of 2.45 GHz and are separated by mass with a mass resolution of M/\\Delta M\\sim 1500. In the focal plane of the magnetic analyzer a front strip detector surrounded by side detectors will be placed to determine the mass according to the signals from the detected alpha-particles or fission fragments with efficiency of about 90 %. In comparison to other existing in-flight recoil separators, the present setup will be characterized by higher efficiency and high selectivity relative to background reaction products. The setup MASHA may be used also in the investigation of nuclear reactions of different type induced by stable and radioactive beams.

  4. Optimization of an on-line function generation

    CERN Document Server

    Versteele, C

    1977-01-01

    A particular example of process control is the analog function generator of the CERN proton synchrotron. For magnet field correction, some magnets have to follow reference currents synchronous with the pulses of the synchrotron. Depending on the dynamic behaviour of the magnet system to be controlled, the output current will show a somewhat distorted image of the reference current used as input. An on-line computer strategy has been designed to compensate the distortions: i.e. to adjust the input function at successive pulses in such a way that the output current follows the reference as closely as required. However, the identification of such a system is not carried out because it is difficult and singular in any case. Modifications cannot be computed directly, but will result from an iterative strategy: the closed-loop adaptive control is based on a maximization procedure, requiring little memory and no gradient information. The algorithm is a variant of the optimization method called extended sequential se...

  5. Performing maintenance activities on-line a risk perspective

    International Nuclear Information System (INIS)

    Darling, S.S.; Mairs, T.P.

    1993-01-01

    The US nuclear power industry is attempting to deal with the issue of optimizing the performance of maintenance activities with the advent of the maintenance rule. The impact of any maintenance activity on the safe operation of a nuclear power facility can be quantified on the basis of risk. Therefore, it is incumbent upon the industry to accommodate the regulator and present a maintenance optimization program in terms that explicitly address the potential risk inherent in its concept and implementation. The motivation for utilities to perform maintenance while the plant is operating (i.e., on-line) is readily perceived to offer the following advantages: 1. greater system availability; 2. higher plant capacity factor; 3. more evenly distributed workload for the maintenance department; and 4. overall safer plant operation. However, risks inherent in undertaking maintenance activities during power operation could amount to the realization that reapportionment of these tasks is not cost-beneficial. Therefore, it is important that any utility considering implementing such a paradigm in maintenance philosophy establish a rigorous process to select, perform, and monitor maintenance tasks performed while operating

  6. Knowledge-based on-line vibration monitoring diagnose

    International Nuclear Information System (INIS)

    Johansson, L.G.; Karlsson, A.; Noeremark, A.

    1990-01-01

    ABB STAL developed some years ago a knowledge-based on-line vibration analysis system (working-name KOVA). KOVA is intended to work together with some type of vibration monitoring system, at present it is adapted to TVM 300. KOVA has no controlling function. It will only diagnose the actual situation and give the user explanations and proposals for actions to be taken. During the developing work, great experience has been gained of the features this type of system demands. This paper will present the outlines of the application and also discuss how to make diagnoses based both on general rules as well as on historical vibration cases for that particular unit (or identical units9. Another subject that this paper will outline, is the representation and evaluation of knowledge. KOVA serves as a decision-support system for the operator. Since KOVA will often give the operator more than one possible diagnosis as the cause of a fault, it is of great importance to give the operator comprehensive explanations and as many facts as possible. It is also important to rank the suggested diagnoses in some way. In KOVA these demands are effectively supported. The models and tools used to realize this functionality will be described in this paper

  7. On-line monitoring of lithium carbonate dissolution

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yuzhu; Song, Xingfu; Wang, Jin; Luo, Yan; Yu, Jianguo [National Engineering Research Center for Integrated Utilization Salt Lake Resources, East China University of Science and Technology, Shanghai (China)

    2009-11-15

    Dissolution of lithium carbonate (Li{sub 2}CO{sub 3}) in aqueous solution was investigated using three on-line apparatuses: the concentration of Li{sub 2}CO{sub 3} was measured by electrical conductivity equipment; CLD (Chord Length Distribution) was monitored by FBRM (Focused Beam Reflectance Measurement); crystal image was observed by PVM (Particle Video Microscope). Results show dissolution rate goes up with a decrease of particle size, and with an increase in temperature; stirring speed causes little impact on dissolution; ultrasound facilitates dissolution obviously. The CLD evolution and crystal images of Li{sub 2}CO{sub 3}powders in stirred fluid were observed detailedly by FBRM and PVM during dissolution. Experimental data were fitted to Avrami model, through which the activation energy was found to be 34.35 kJ/mol. PBE (Population Balance Equation) and moment transform were introduced to calculate dissolution kinetics, obtaining correlation equations of particle size decreasing rate as a function of temperature and undersaturation. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Building collaboration tools and access to on-line facilities

    International Nuclear Information System (INIS)

    Agarwal, D.; Sachs, S.

    1996-11-01

    Network-based facilities will allow researchers at different locations to collaborate on experiments as if they all were together in the same laboratory. The expected value of these geographically distributed environments includes substantially increased effectiveness in doing science, and an enabling capability for analytical and high-value production use by industry. The Distributed, Collaboratory Experiment Environments (DCEE) Program consists of four projects that were established to build prototype remote experiment and collaborative environments. The work undertaken in this project represents some of the research and development of the mechanisms and infrastructure required to make collaboratories a reality. Some of these mechanisms have already been developed. Several other mechanisms, such as data dissemination, resource management for the sharing of experiment control, safety and security, electronic notebooks, elements of telepresence, and integrated user interfaces need further research and development. The pilot application for these collaborative tools is the Advanced Light Source (ALS) Beamline 7.0 at the Ernest Orlando Lawrence Berkeley Laboratory. The ALS is a particle accelerator and is a source of very high brilliance soft X-ray beams. One experimental facility is the Spectro-Microscopy Facility Beamline 7.0. Through this project, the Spectro-Microscopy Facility will be opened up to users from a wide range of organizations. The goal is to build software that will not only put the ALS Beamline 7.0 on-line, but will also serve as building blocks for future collaboratory development

  9. EXPANDING ACADEMIC VOCABULARY WITH AN INTERACTIVE ON-LINE DATABASE

    Directory of Open Access Journals (Sweden)

    Marlise Horst

    2005-05-01

    Full Text Available University students used a set of existing and purpose-built on-line tools for vocabulary learning in an experimental ESL course. The resources included concordance, dictionary, cloze-builder, hypertext, and a database with interactive self-quizzing feature (all freely available at www.lextutor.ca. The vocabulary targeted for learning consisted of (a Coxhead's (2000 Academic Word List, a list of items that occur frequently in university textbooks, and (b unfamiliar words students had met in academic texts and selected for entry into the class database. The suite of tools were designed to foster retention by engaging learners in deep processing, an aspect that is often described as missing in computer exercises for vocabulary learning. Database entries were examined to determine whether context sentences supported word meanings adequately and whether entered words reflected the unavailability of cognates in the various first languages of the participants. Pre- and post-treatment performance on tests of knowledge of words targeted for learning in the course were compared to establish learning gains. Regression analyses investigated connections between use of specific computer tools and gains.

  10. Design considerations for on-line vibration diagnostic systems

    International Nuclear Information System (INIS)

    Branagan, L.A.; Schjeibel, J.R.

    1989-01-01

    The decisions made in the design of a data system for on-line vibration diagnostic system in power plants define how well the system will meet its intended goals. Direct use of the data for performing troubleshooting or developing operating correlations requires an understanding of the subtle impact of the design decisions incorporated in the data system. A data system includes data acquisition, data storage, and data retrieval. Data acquisition includes the selection of sensors, of vibration measurement modes, and of the time stamping format, and the arrangement of data collection cycles. Data storage requires the evaluation of data compression options and of data segregation. Data retrieval design requires an understanding of the data storage and acquisition techniques. Each of these options and design decisions involves compromises, many of which are discussed in this paper. Actual and synthetic data are presented to illustrate these points. The authors' experience with multiple data collection cycles, with frequent monitoring, and with storage by exception suggests that these techniques can be developed into an effective diagnostic system

  11. Study of the on line radioactive multicharged ion production

    International Nuclear Information System (INIS)

    Lecesne, N.

    1997-01-01

    This work is directly related to the SPIRAL project (Systeme de Production d'Ions Radioactifs Acceleres en Ligne) which will start at GANIL at the end of 1998. The aim of the thesis was to study the on line radioactive multicharged ion beam production stages, i.e. the production and diffusion of the radioactive nuclei in a thick target, their possible transfer up to an ECR ion source and their ionisation. Production cross sections of radioactive neutron rich nuclei, formed by fragmentation of a heavy ion beam in a thick target, were measured. An external target-ECR source system, dedicated to the radioactive noble gases production, and two internal target-ECR source systems, dedicated to the radioactive condensable element production, were built and tested on the SIRa tests bench (Separateur d'Ions Radioactifs). Different detection configurations were elaborated in order to identify the radioactive nuclei and estimate their production yields. Finally, a new method for measuring the overall efficiency of the separator was developed and allowed to study the diffusion properties of radioactive noble gases in various targets. (author)

  12. On-line confidence monitoring during decision making.

    Science.gov (United States)

    Dotan, Dror; Meyniel, Florent; Dehaene, Stanislas

    2018-02-01

    Humans can readily assess their degree of confidence in their decisions. Two models of confidence computation have been proposed: post hoc computation using post-decision variables and heuristics, versus online computation using continuous assessment of evidence throughout the decision-making process. Here, we arbitrate between these theories by continuously monitoring finger movements during a manual sequential decision-making task. Analysis of finger kinematics indicated that subjects kept separate online records of evidence and confidence: finger deviation continuously reflected the ongoing accumulation of evidence, whereas finger speed continuously reflected the momentary degree of confidence. Furthermore, end-of-trial finger speed predicted the post-decisional subjective confidence rating. These data indicate that confidence is computed on-line, throughout the decision process. Speed-confidence correlations were previously interpreted as a post-decision heuristics, whereby slow decisions decrease subjective confidence, but our results suggest an adaptive mechanism that involves the opposite causality: by slowing down when unconfident, participants gain time to improve their decisions. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. 3081/E processor and its on-line use

    International Nuclear Information System (INIS)

    Rankin, P.; Bricaud, B.; Gravina, M.

    1985-05-01

    The 3081/E is a second generation emulator of a mainframe IBM. One of it's applications will be to form part of the data acquisition system of the upgraded Mark II detector for data taking at the SLAC linear collider. Since the processor does not have direct connections to I/O devices a FASTBUS interface will be provided to allow communication with both SLAC Scanner Processors (which are responsible for the accumulation of data at a crate level) and the experiment's VAX 8600 mainframe. The 3081/E's will supply a significant amount of on-line computing power to the experiment (a single 3081/E is equivalent to 4 to 5 VAX 11/780's). A major advantage of the 3081/E is that program development can be done on an IBM mainframe (such as the one used for off-line analysis) which gives the programmer access to a full range of debugging tools. The processor's performance can be continually monitored by comparison of the results obtained using it to those given when the same program is run on an IBM computer. 9 refs

  14. Gated Treatment Delivery Verification With On-Line Megavoltage Fluoroscopy

    International Nuclear Information System (INIS)

    Tai An; Christensen, James D.; Gore, Elizabeth; Khamene, Ali; Boettger, Thomas; Li, X. Allen

    2010-01-01

    Purpose: To develop and clinically demonstrate the use of on-line real-time megavoltage (MV) fluoroscopy for gated treatment delivery verification. Methods and Materials: Megavoltage fluoroscopy (MVF) image sequences were acquired using a flat panel equipped for MV cone-beam CT in synchrony with the respiratory signal obtained from the Anzai gating device. The MVF images can be obtained immediately before or during gated treatment delivery. A prototype software tool (named RTReg4D) was developed to register MVF images with phase-sequenced digitally reconstructed radiograph images generated from the treatment planning system based on four-dimensional CT. The image registration can be used to reposition the patient before or during treatment delivery. To demonstrate the reliability and clinical usefulness, the system was first tested using a thoracic phantom and then prospectively in actual patient treatments under an institutional review board-approved protocol. Results: The quality of the MVF images for lung tumors is adequate for image registration with phase-sequenced digitally reconstructed radiographs. The MVF was found to be useful for monitoring inter- and intrafractional variations of tumor positions. With the planning target volume contour displayed on the MVF images, the system can verify whether the moving target stays within the planning target volume margin during gated delivery. Conclusions: The use of MVF images was found to be clinically effective in detecting discrepancies in tumor location before and during respiration-gated treatment delivery. The tools and process developed can be useful for gated treatment delivery verification.

  15. Wash water waste pretreatment system

    Science.gov (United States)

    1977-01-01

    Investigations were completed on wash waters based on each candidate personal cleansing agent. Evaluations of coagulants, antifoam agents, and the effect of promising antifoams on the chemical precipitation were included. Based on these evaluations two candidate soaps as well as their companion antifoam agents were selected for further work. Operating parameters included the effect of soap concentration, ferric chloride concentration, duration of mixing, and pore size of depth filters on the degree of soap removal. The effect of pressure on water flow through filter cartridges and on the rate of decline of water flow was also investigated. The culmination of the program was the recommendation of a pretreatment concept based on chemical precipitation followed by pressure filtration.

  16. Testing of Candidate Polymeric Materials for Compatibility with Pure Alternate Pretreat as Part of the Universal Waste Management System (UWMS)

    Science.gov (United States)

    Wingard, C. D.

    2018-01-01

    The Universal Waste Management System (UWMS) is an improved Waste Collection System for astronauts living and working in low Earth orbit spacecraft. Polymeric materials used in water recovery on International Space Station are regularly exposed to phosphoric acid-treated 'pretreated' urine. Polymeric materials used in UWMS are not only exposed to pretreated urine, but also to concentrated phosphoric acid with oxidizer before dilution known as 'pure pretreat.' Samples of five different polymeric materials immersed in pure pretreat for 1 year were tested for liquid compatibility by measuring changes in storage modulus with a dynamic mechanical analyzer.

  17. Biomass Deconstruction and Pretreatment | Bioenergy | NREL

    Science.gov (United States)

    Deconstruction and Pretreatment Biomass Deconstruction and Pretreatment Our mission is to transform -cyclohexane hydrocarbons were produced by noble metal and acid zeoloite catalytic upgrading of biomass-derived by mechanical refining process. The left side shows biomass feedstock (represented by brown spheres

  18. Effects of pre-treatment technologies on quantity and quality of source-sorted municipal organic waste for biogas recovery

    DEFF Research Database (Denmark)

    Hansen, Trine Lund; Jansen, J.l.C.; Davidsson, Å.

    2007-01-01

    , collection bag material (plastic or paper) and easily degradable organic matter. Furthermore, the particle size of the biomass was related to the pre-treatment technology. The content of plastic in the biomass depended both on the actual collection bag material used in the system and the pre......Source-sorted municipal organic waste collected from different dwelling types in five Danish cities and pre-treated at three different plants was sampled and characterized several times during one year to investigate the origin of any differences in composition of the pre-treated waste introduced...... by city, pre-treatment technology, dwelling type or annual season. The investigated pre-treatment technologies were screw press, disc screen and shredder + magnet. The average quantity of pre-treated organic waste (biomass) produced from the incoming waste varied between the investigated pre...

  19. Using Reading Guides and On-Line Quizzes to Improve Reading Compliance and Quiz Scores

    Science.gov (United States)

    Maurer, Trent W.; Longfield, Judith

    2015-01-01

    This study compared students' daily in-class reading quiz scores in an introductory Child Development course across five conditions: control, reading guide only, reading guide and on-line practice quiz, reading guide and on-line graded quiz, and reading guide and both types of on-line quizzes. At the beginning of class, students completed a 5-item…

  20. On-line Versus Face-to-Face Education: Utilizing Technology to Increase Effectiveness

    Science.gov (United States)

    2012-05-17

    Andragogy and learner-centered education provided in on-line education present excellent results. Secondly, the cost of on-line education compared to...13 Pedagogy versus Andragogy ...achieving learning outcomes. However, Andragogy and learner centered education provided in on-line education presents excellent results. Secondly, the cost

  1. Bonding effectiveness to different chemically pre-treated dental zirconia.

    Science.gov (United States)

    Inokoshi, Masanao; Poitevin, André; De Munck, Jan; Minakuchi, Shunsuke; Van Meerbeek, Bart

    2014-09-01

    The objective of this study was to evaluate the effect of different chemical pre-treatments on the bond durability to dental zirconia. Fully sintered IPS e.max ZirCAD (Ivoclar Vivadent) blocks were subjected to tribochemical silica sandblasting (CoJet, 3M ESPE). The zirconia samples were additionally pre-treated using one of four zirconia primers/adhesives (Clearfil Ceramic Primer, Kuraray Noritake; Monobond Plus, Ivoclar Vivadent; Scotchbond Universal, 3M ESPE; Z-PRIME Plus, Bisco). Finally, two identically pre-treated zirconia blocks were bonded together using composite cement (RelyX Ultimate, 3M ESPE). The specimens were trimmed at the interface to a cylindrical hourglass and stored in distilled water (7 days, 37 °C), after which they were randomly tested as is or subjected to mechanical ageing involving cyclic tensile stress (10 N, 10 Hz, 10,000 cycles). Subsequently, the micro-tensile bond strength was determined, and SEM fractographic analysis performed. Weibull analysis revealed the highest Weibull scale and shape parameters for the 'Clearfil Ceramic Primer/mechanical ageing' combination. Chemical pre-treatment of CoJet (3M ESPE) sandblasted zirconia using Clearfil Ceramic Primer (Kuraray Noritake) and Monobond Plus (Ivoclar Vivadent) revealed a significantly higher bond strength than when Scotchbond Universal (3M ESPE) and Z-PRIME Plus (Bisco) were used. After ageing, Clearfil Ceramic Primer (Kuraray Noritake) revealed the most stable bond durability. Combined mechanical/chemical pre-treatment, the latter with either Clearfil Ceramic Primer (Kuraray Noritake) or Monobond Plus (Ivoclar Vivadent), resulted in the most durable bond to zirconia. As a standard procedure to durably bond zirconia to tooth tissue, the application of a combined 10-methacryloyloxydecyl dihydrogen phosphate/silane ceramic primer to zirconia is clinically highly recommended.

  2. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    Thermo Power Corporation has proven the technical viability of an on-line, real-time alpha radionuclide instrument for aqueous sample analysis through laboratory and initial field tests of the instrument. The instrument has been shown to be isotonically sensitive to extremely low (ten parts per trillion, or femto Curies per liter) levels of a broad range of radioisotopes. Performance enhancement and other scaling data obtained during the course of this investigation have shown that on-line, real-time operation is possible, with a sub 30-minute response time analyzing 20 ppb (30 pCi/1) natural uranium. Now that these initial field tests in Oak Ridge, Tennessee have been successfully completed, Thermo Power plans to conduct comprehensive field tests of the instrument. The purpose of these endurance tests will be to determine the endurance characteristics of the Thermo Alpha Monitor for Water when it is used by non-Thermo Power personnel in a series of one or more extended field tests. Such endurance testing is the vital next step towards the commercialization of the Alpha Monitor. Subsequently, it will be possible to provide the DOE with an instrument that has the capability of obtaining rapid feedback about the concentrations of alpha-emitting isotope contamination in effluent water streams (Subsurface Contaminants Focus Area). It will also be useful for process control of remediation and D and D operations such as monitoring scrubber/rinse water radioactivity levels (Mixed Waste, Plutonium and D and D Focus Areas)

  3. Inverse kinetics equations for on line measurement of reactivity using personal computer

    International Nuclear Information System (INIS)

    Ratemi, Wajdi; El Gadamsi, Walied; Beleid, Abdul Kariem

    1993-01-01

    Computer with their astonishing speed of calculations along with their easy connection to real systems, are very appropriate for digital measurements of real system variables. In the nuclear industry, such computer application will produce compact control rooms of real power plants, where information and results display can be obtained through push button concept. In our study, we use two personal computers for the purpose of simulation and measurement. One of them is used as a digital simulator to a real reactor, where we effectively simulate the reactor power through a cross talk network. The computed power is passed at certain chosen sampling time to the other computer. The purpose of the other computer is to use the inverse kinetics equations to calculate the reactivity parameter based on the received power and then it performs on line display of the power curve and the reactivity curve using color graphics. In this study, we use the one group version of the inverse kinetics algorithm which can easily be extended to larger group version. The language of programming used in Turbo BASIC, which is very comparable, in terms of efficiency, to FORTRAN language, besides its effective graphics routines. With the use of the extended version of the Inverse Kinetics algorithm, we can effectively apply this techniques of measurement for the purpose of on line display of the reactivity of the Tajoura Research Reactor. (author)

  4. Perspectives for on-line analysis of bauxite by neutron irradiation

    Science.gov (United States)

    Beurton, Gabriel; Ledru, Bertrand; Letourneur, Philippe

    1995-03-01

    The interest in bauxite as a major source of alumina results in a strong demand for on-line instrumentation suitable for sorting, blending, and processing operations at the bauxite mine and for monitoring instrumentation in the Bayer process. The results of laboratory experiments based on neutron interactions with bauxite are described. The technique was chosen in order to overcome the problem of spatial heterogeneity in bulk mineral analysis. The evaluated elements contributed to approximately 99.5% of the sample weight. In addition, the measurements provide valuable information on physical parameters such as density, hygrometry, and material flow. Using a pulsed generator, the analysis system offers potential for on-line measurements (borehole logging or conveyor belt). An overall description of the experimental set-up is given. The experimental data include measurements of natural radioactivity, delayed radioactivity induced by activation, and prompt gamma rays following neutron reaction. In situ applications of neutron interactions provide continuous analysis and produce results which are more statistically significant. The key factors contributing to advances in industrial applications are the development of high count rate gamma spectroscopy and computational tools to design measurement systems and interpret their results.

  5. Development and Integration of on-line Data Analysis for the ALICE Experiment

    CERN Document Server

    Richter, Matthias

    2009-01-01

    The ALICE detector setup is a dedicated experiment in Heavy Ion Physics, located at the Large Hadron Collider (LHC) at the European Organization for Nuclear Research (CERN)/ Geneva. Its various sub-detectors are electronically read out by a few millions of channels and are expected to provide a huge sample of data for the investigation of strongly interacting matter. A data rate of up to 25 GByte/s imposes a challenge to both storage facilities and subsequent data analysis. On-line data processing is applied in order to reduce the data volume and selection of interesting events is suggested to increase the valuable information in the recorded data. In general, trigger systems cover the task of event selection. As the first signal needs to be available immediately after the collision, often a multi-level triggering scheme is applied. Fast detectors are deployed to generate different levels of hardware triggers. Subsequent software triggers accomplish event selection on the basis of on-line analysis. A High-Lev...

  6. On-line liquid-effluent monitoring of sewage at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Dreicer, M.; Cate, J.L.; Rueppel, D.W.; Huntzinger, C.J.; Gonzalez, M.A.

    1982-01-01

    An automatic on line sewage effluent monitoring system has been developed. A representative fraction of the total waste stream leaving the site is monitored for pH, radiation, and metals as it passes through a detection assembly. This assembly consists of an industrial pH probe, NaI radiation detectors, and an x-ray fluorescence metal detector. A microprocessor collects, reduces and analyzes the data to determine if the levels are acceptable by established environmental limits. Currently, if preset levels are exceeded, a sample of the suspect sewage is automatically collected for further analysis, and an alarm is sent to a station where personnel can be alerted to respond on a 24-hour basis. Since at least four hours pass before LLNL effluent reaches the treatment plant, sufficient time is available to alert emergency personnel, evaluate the situation, and if necessary arrange for diversion of the material to emergency holding basins at the treatment plant. Information on the current system is presented, and progress is reported in developing an on-line tritium monitor as an addition to the assembly

  7. Differential regional gray matter volumes in patients with on-line game addiction and professional gamers

    Science.gov (United States)

    Han, Doug Hyun; Lyoo, In Kyoon; Renshaw, Perry F.

    2015-01-01

    Patients with on-line game addiction (POGA) and professional video game players play video games for extended periods of time, but experience very different consequences for their on-line game play. Brain regions consisting of anterior cingulate, thalamus and occpito-temporal areas may increase the likelihood of becoming a pro-gamer or POGA. Twenty POGA, seventeen pro-gamers, and eighteen healthy comparison subjects (HC) were recruited. All magnetic resonance imaging (MRI) was performed on a 1.5 Tesla Espree MRI scanner (SIEMENS, Erlangen, Germany). Voxel-wise comparisons of gray matter volume were performed between the groups using the two-sample t-test with statistical parametric mapping (SPM5). Compared to HC, the POGA group showed increased impulsiveness and perseverative errors, and volume in left thalamus gray matter, but decreased gray matter volume in both inferior temporal gyri, right middle occipital gyrus, and left inferior occipital gyrus, compared with HC. Pro-gamers showed increased gray matter volume in left cingulate gyrus, but decreased gray matter volume in left middle occipital gyrus and right inferior temporal gyrus compared with HC. Additionally, the pro-gamer group showed increased gray matter volume in left cingulate gyrus and decreased left thalamus gray matter volume compared with the POGA group. The current study suggests that increased gray matter volumes of the left cingulate gyrus in pro-gamers and of the left thalamus in POGA may contribute to the different clinical characteristics of pro-gamers and POGA. PMID:22277302

  8. Comparison of manual and automated pretreatment methods for AMS radiocarbon dating of plant fossils

    Science.gov (United States)

    Bradley, L.A.; Stafford, Thomas W.

    1994-01-01

    A new automated pretreatment system for the preparation of materials submitted for accelerator mass spectrometry (AMS) analysis is less time-consuming and results in a higher sample yield. The new procedure was tested using two groups of plant fossils: one group was pretreated using the traditional method, and the second, using the automated pretreatment apparatus. The time it took to complete the procedure and the amount of sample material remaining were compared. The automated pretreatment apparatus proved to be more than three times faster and, in most cases, produced a higher yield. A darker discoloration of the KOH solutions was observed indicating that the automated system is more thorough in removing humates from the specimen compared to the manual method. -Authors

  9. Innovative pretreatment strategies for biogas production.

    Science.gov (United States)

    Patinvoh, Regina J; Osadolor, Osagie A; Chandolias, Konstantinos; Sárvári Horváth, Ilona; Taherzadeh, Mohammad J

    2017-01-01

    Biogas or biomethane is traditionally produced via anaerobic digestion, or recently by thermochemical or a combination of thermochemical and biological processes via syngas (CO and H 2 ) fermentation. However, many of the feedstocks have recalcitrant structure and are difficult to digest (e.g., lignocelluloses or keratins), or they have toxic compounds (such as fruit flavors or high ammonia content), or not digestible at all (e.g., plastics). To overcome these challenges, innovative strategies for enhanced and economically favorable biogas production were proposed in this review. The strategies considered are commonly known physical pretreatment, rapid decompression, autohydrolysis, acid- or alkali pretreatments, solvents (e.g. for lignin or cellulose) pretreatments or leaching, supercritical, oxidative or biological pretreatments, as well as combined gasification and fermentation, integrated biogas production and pretreatment, innovative biogas digester design, co-digestion, and bio-augmentation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. The effect of family therapy on the changes in the severity of on-line game play and brain activity in adolescents with on-line game addiction

    Science.gov (United States)

    Han, Doug Hyun; Kim, Sun Mi; Lee, Young Sik; Renshaw, Perry F.

    2015-01-01

    We evaluated whether a brief 3-week family therapy intervention would change patterns of brain activation in response to affection and gaming cues in adolescents from dysfunctional families who met criteria for on-line game addiction. Fifteen adolescents with on-line game addiction and fifteen adolescents without problematic on-line game play and an intact family structure were recruited. Over 3 weeks, families were asked to carry out homework assignments focused on increasing family cohesion for more than 1 hour/day and 4 days/week. Before therapy, adolescents with on-line game addiction demonstrated decreased activity as measured by functional magnetic resonance imaging (fMRI) within the caudate, middle temporal gyrus, and occipital lobe in response to images depicting parental affection and increased activity of the middle frontal and inferior parietal in response scenes from on-line games, relative to healthy comparison subjects. Improvement in perceived family cohesion following 3 weeks of treatment was associated with an increase in the activity of the caudate nucleus in response to affection stimuli and was inversely correlated with changes in on-line game playing time. With evidence of brain activation changes in response to on-line game playing cues and images depicting parental love, the present findings suggest that family cohesion may be an important factor in the treatment of problematic on-line game playing. PMID:22698763

  11. TiO2/UV based photocatalytic pretreatment of wheat straw for biogas production

    DEFF Research Database (Denmark)

    Alvarado-Morales, Merlin; Tsapekos, Panagiotis; Awais, Muhammad

    2017-01-01

    samples and the pretreatment with the best performance was further tested in continuous mode operation. From BMP assays, 1.5% (w/w) TiO2/straw at 3 h of UV light exposure pretreatment resulted in 37% (p CSTRs. It was concluded that the presence of TiO2...

  12. In situ microscopy for on-line determination of biomass.

    Science.gov (United States)

    Bittner, C; Wehnert, G; Scheper, T

    1998-10-05

    A sensor is presented, which allows on-line microscopic observation of microorganisms during fermentations in bioreactors. This sensor, an In Situ Microscope (ISM) consists of a direct-light microscope with a measuring chamber, integrated in a 25 mm stainless steel tube, two CCD-cameras, and two frame-grabbers. The data obtained are processed by an automatic image analysis system. The ISM is connected with the bioreactor via a standard port, and it is immersed directly in the culture liquid-in our case Saccharomyces cerevisiae in a synthetic medium. The microscopic examination of the liquid is performed in the measuring chamber, which is situated near the front end of the sensor head. The measuring chamber is opened and closed periodically. In the open state, the liquid in the bioreactor flows unrestricted through the chamber. In closing, a defined volume of 2,2. 10(-8) mL of the liquid becomes enclosed. After a few seconds, when the movement of the cells in the enclosed culture has stopped, they are examined with the microscope. The microscopic images of the cells are registered with the CCD-cameras and are visualized on a monitor, allowing a direct view of the cell population. After detection, the measuring chamber reopens, and the enclosed liquid is released. The images obtained are evaluated as to cell concentration, cell size, cell volume, biomass, and other relevant parameters simultaneously by automatic image analysis. With a PC (486/33 MHz), image processing takes about 15 s per image. The detection range tested when measuring cells of S. cerevisiae is about 10(6) to 10(9) cells/mL (equivalent to a biomass of 0.01 g/L to 12 g/L). The calculated biomass values correlate very well with those obtained using dry weight analysis. Furthermore, histograms can be calculated, which are comparable to those obtained by flow cytometry. Copyright 1998 John Wiley & Sons, Inc.

  13. On-line sensor technology for food manufacturing industry. Shokuhin bun prime ya ni okeru on-line sensor gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Komiya, K. (Ajinomoto Co. Inc., Tokyo (Japan))

    1990-08-05

    This paper introduced the sensor technology for food manufacturing industry. If sugar concentration in main raw material is too high in the amino acid fermentation, control of the concentration is required because fungi growth is inhibited. A controlling method for sugar concentration was developed by using the correlation between consumption of NH {sub 3} for pH adjustment and sugar consumption in place of conventional analyzing method and was introduced in the gulutamic acid fermantation. BOD sensor was developed to enable the selective measurement of organic substances which can be processed by organisms, and measuring time was shortened from previous five days to 30 minutes. Since many organics absorb infrared ray, near infrared analysis is suitable for food analysis and on-line analysis has high possibility. When this method is applied to measure moisture in fishes and meats, continuous measurement can be made nondestructively and without contacting, and further the precision is {plus minus} 0.1%. Simultaneous multi-composition analyses are carried out by continuous spectrum and near infrared method using higher rate scanning. Sensor development for taste and smell has started. 10 refs., 4 figs., 4 refs.

  14. On-line analysis of algae in water by discrete three-dimensional fluorescence spectroscopy.

    Science.gov (United States)

    Zhao, Nanjing; Zhang, Xiaoling; Yin, Gaofang; Yang, Ruifang; Hu, Li; Chen, Shuang; Liu, Jianguo; Liu, Wenqing

    2018-03-19

    In view of the problem of the on-line measurement of algae classification, a method of algae classification and concentration determination based on the discrete three-dimensional fluorescence spectra was studied in this work. The discrete three-dimensional fluorescence spectra of twelve common species of algae belonging to five categories were analyzed, the discrete three-dimensional standard spectra of five categories were built, and the recognition, classification and concentration prediction of algae categories were realized by the discrete three-dimensional fluorescence spectra coupled with non-negative weighted least squares linear regression analysis. The results show that similarities between discrete three-dimensional standard spectra of different categories were reduced and the accuracies of recognition, classification and concentration prediction of the algae categories were significantly improved. By comparing with that of the chlorophyll a fluorescence excitation spectra method, the recognition accuracy rate in pure samples by discrete three-dimensional fluorescence spectra is improved 1.38%, and the recovery rate and classification accuracy in pure diatom samples 34.1% and 46.8%, respectively; the recognition accuracy rate of mixed samples by discrete-three dimensional fluorescence spectra is enhanced by 26.1%, the recovery rate of mixed samples with Chlorophyta 37.8%, and the classification accuracy of mixed samples with diatoms 54.6%.

  15. On-line NIR analysis of fat, water and protein in industrial scale ground meat batches.

    Science.gov (United States)

    Tøgersen, G; Isaksson, T; Nilsen, B N; Bakker, E A; Hildrum, K I

    1999-01-01

    Fat, water and protein contents in industrial scale meat batches were determined on-line by near infrared (NIR) reflectance spectroscopy. The NIR instrument was mounted at the outlet of a large meat grinder, and the measurements were performed in an industrial environment. Beef and pork samples, with chemical compositions of 7-26% fat, 58-75% water and 15-21% protein, were processed with hole diameters of 13mm in the grinder plate. Calibrations were made both for a combined set of beef and pork samples, and for separate sets of beef and pork samples. Validations were either done by full cross validation of the calibration set, or by bias corrected prediction of a test set. Prediction errors for the two sample sets, expressed as root mean square errors of cross validation or standard error of prediction, were in the ranges 0.82-1.49% fat, 0.94-1.33% water and 0.35-0.70% protein, depending of sample set and species of animal. The presented application is an improvement to the existing manual meat standardisation procedure, and has been implemented for regular use in a Norwegian meat manufacturing plant.

  16. Pretreatment of the macroalgae Chaetomorpha linum for the production of bioethanol - Comparison of five pretreatment technologies

    DEFF Research Database (Denmark)

    Schultz-Jensen, Nadja; Thygesen, Anders; Thomsen, Sune Tjalfe

    2013-01-01

    -assisted pretreatment (PAP) and ball milling (BM), to determine effects of the pretreatment methods on the conversion of C. linum into ethanol by simultaneous saccharification and fermentation (SSF). WO and BM showed the highest ethanol yield of 44. g ethanol/100. g glucan, which was close to the theoretical ethanol......A qualified estimate for pretreatment of the macroalgae Chaetomorpha linum for ethanol production was given, based on the experience of pretreatment of land-based biomass. C. linum was subjected to hydrothermal pretreatment (HTT), wet oxidation (WO), steam explosion (STEX), plasma...... yield of 57. g ethanol/100. g glucan. A 64% higher ethanol yield, based on raw material, was reached after pretreatment with WO and BM compared with unpretreated C. linum, however 50% of the biomass was lost during WO. Results indicated that the right combination of pretreatment and marine macroalgae...

  17. Microwave-Assisted Alkali Pre-Treatment, Densification and Enzymatic Saccharification of Canola Straw and Oat Hull.

    Science.gov (United States)

    Agu, Obiora S; Tabil, Lope G; Dumonceaux, Tim

    2017-03-26

    The effects of microwave-assisted alkali pre-treatment on pellets' characteristics and enzymatic saccharification for bioethanol production using lignocellulosic biomass of canola straw and oat hull were investigated. The ground canola straw and oat hull were immersed in distilled water, sodium hydroxide and potassium hydroxide solutions at two concentrations (0.75% and 1.5% w/v) and exposed to microwave radiation at power level 713 W and three residence times (6, 12 and 18 min). Bulk and particle densities of ground biomass samples were determined. Alkaline-microwave pre-treated and untreated samples were subjected to single pelleting test in an Instron universal machine, pre-set to a load of 4000 N. The measured parameters, pellet density, tensile strength and dimensional stability were evaluated and the results showed that the microwave-assisted alkali pre-treated pellets had a significantly higher density and tensile strength compared to samples that were untreated or pre-treated by microwave alone. The chemical composition analysis showed that microwave-assisted alkali pre-treatment was able to disrupt and break down the lignocellulosic structure of the samples, creating an area of cellulose accessible to cellulase reactivity. The best enzymatic saccharification results gave a high glucose yield of 110.05 mg/g dry sample for canola straw ground in a 1.6 mm screen hammer mill and pre-treated with 1.5% NaOH for 18 min, and a 99.10 mg/g dry sample for oat hull ground in a 1.6 mm screen hammer mill and pre-treated with 0.75% NaOH for 18 min microwave-assisted alkali pre-treatments. The effects of pre-treatment results were supported by SEM analysis. Overall, it was found that microwave-assisted alkali pre-treatment of canola straw and oat hull at a short residence time enhanced glucose yield.

  18. Fast Pyrolysis of Tropical Biomass Species and Influence of Water Pretreatment on Product Distributions.

    Science.gov (United States)

    Morgan, Trevor James; Turn, Scott Q; Sun, Ning; George, Anthe

    2016-01-01

    The fast pyrolysis behaviour of pretreated banagrass was examined at four temperatures (between 400 and 600 C) and four residence times (between ~1.2 and 12 s). The pretreatment used water washing/leaching to reduce the inorganic content of the banagrass. Yields of bio-oil, permanent gases and char were determined at each reaction condition and compared to previously published results from untreated banagrass. Comparing the bio-oil yields from the untreated and pretreated banagrass shows that the yields were greater from the pretreated banagrass by 4 to 11 wt% (absolute) at all reaction conditions. The effect of pretreatment (i.e. reducing the amount of ash, and alkali and alkali earth metals) on pyrolysis products is: 1) to increase the dry bio-oil yield, 2) to decrease the amount of undetected material, 3) to produce a slight increase in CO yield or no change, 4) to slightly decrease CO2 yield or no change, and 5) to produce a more stable bio-oil (less aging). Char yield and total gas yield were unaffected by feedstock pretreatment. Four other tropical biomass species were also pyrolyzed under one condition (450°C and 1.4 s residence time) for comparison to the banagrass results. The samples include two hardwoods: leucaena and eucalyptus, and two grasses: sugarcane bagasse and energy-cane. A sample of pretreated energy-cane was also pyrolyzed. Of the materials tested, the best feedstocks for fast pyrolysis were sugarcane bagasse, pretreated energy cane and eucalyptus based on the yields of 'dry bio-oil', CO and CO2. On the same basis, the least productive feedstocks are untreated banagrass followed by pretreated banagrass and leucaena.

  19. Fast Pyrolysis of Tropical Biomass Species and Influence of Water Pretreatment on Product Distributions.

    Directory of Open Access Journals (Sweden)

    Trevor James Morgan

    Full Text Available The fast pyrolysis behaviour of pretreated banagrass was examined at four temperatures (between 400 and 600 C and four residence times (between ~1.2 and 12 s. The pretreatment used water washing/leaching to reduce the inorganic content of the banagrass. Yields of bio-oil, permanent gases and char were determined at each reaction condition and compared to previously published results from untreated banagrass. Comparing the bio-oil yields from the untreated and pretreated banagrass shows that the yields were greater from the pretreated banagrass by 4 to 11 wt% (absolute at all reaction conditions. The effect of pretreatment (i.e. reducing the amount of ash, and alkali and alkali earth metals on pyrolysis products is: 1 to increase the dry bio-oil yield, 2 to decrease the amount of undetected material, 3 to produce a slight increase in CO yield or no change, 4 to slightly decrease CO2 yield or no change, and 5 to produce a more stable bio-oil (less aging. Char yield and total gas yield were unaffected by feedstock pretreatment. Four other tropical biomass species were also pyrolyzed under one condition (450°C and 1.4 s residence time for comparison to the banagrass results. The samples include two hardwoods: leucaena and eucalyptus, and two grasses: sugarcane bagasse and energy-cane. A sample of pretreated energy-cane was also pyrolyzed. Of the materials tested, the best feedstocks for fast pyrolysis were sugarcane bagasse, pretreated energy cane and eucalyptus based on the yields of 'dry bio-oil', CO and CO2. On the same basis, the least productive feedstocks are untreated banagrass followed by pretreated banagrass and leucaena.

  20. FY 2000 report on the results of the regional consortium R and D project - Regional consortium R and D field. First year report. Development of an on-line/real-time dioxin measuring system; 2000 nendo chiiki consortium kenkyu kaihatsu jigyo - chiiki consortium kenkyu kaihatsu bun'ya. Dioxin no on line real time keisoku sochi no kaihatsu (dai 1 nendo) seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    With the supersonic molecular jet resonance multiple photon ionization mass analysis method (SSJ method) as basement technology, the development was proceeded with of a portable dioxin spectrometer to measure dioxins emitted from incinerator on line and at real time and to control/improve the state of combustion. Studies were made in the following three fields: 1) development of pico second wavelength variable color laser; 2) development of a flight hour type mass spectrometer; 3) development of the pretreatment technology suitable for analysis of dioxins, precursors, etc. by supersonic molecular jet spectroscopy. In 1), the prototype was fabricated to assess the performance, and it was confirmed that the prototype has the targeted characteristics. In 2), as to the coaxial ionization and ring double skimmer electrode system, the convergence and mass resolution of ion were measured, and a possibility of the commercialization was obtained. In 3), it was confirmed that there is a possibility in rapid pretreatment by alumina fiber filter. (NEDO)