WorldWideScience

Sample records for on-line dynamic extraction

  1. The determination of organochlorine pesticides based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Chen Ligang; Ding Lan; Jin Haiyan; Song Daqian; Zhang Huarong; Li Jiantao; Zhang Kun; Wang Yutang; Zhang Hanqi

    2007-01-01

    A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM 010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min -1 . The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g -1 . The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required

  2. On-Line Junction Temperature Monitoring of Switching Devices with Dynamic Compact Thermal Models Extracted with Model Order Reduction

    Directory of Open Access Journals (Sweden)

    Fabio Di Napoli

    2017-02-01

    Full Text Available Residual lifetime estimation has gained a key point among the techniques that improve the reliability and the efficiency of power converters. The main cause of failures are the junction temperature cycles exhibited by switching devices during their normal operation; therefore, reliable power converter lifetime estimation requires the knowledge of the junction temperature time profile. Since on-line dynamic temperature measurements are extremely difficult, in this work an innovative real-time monitoring strategy is proposed, which is capable of estimating the junction temperature profile from the measurement of the dissipated powers through an accurate and compact thermal model of the whole power module. The equations of this model can be easily implemented inside a FPGA, exploiting the control architecture already present in modern power converters. Experimental results on an IGBT power module demonstrate the reliability of the proposed method.

  3. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Kai-Ta; Liu, Pei-Han [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Urban, Pawel L. [Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China); Institute of Molecular Science, National Chiao Tung University, 1001 University Rd, Hsinchu, 300, Taiwan (China)

    2015-09-24

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h{sup −1}). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates

  4. Automated on-line liquid–liquid extraction system for temporal mass spectrometric analysis of dynamic samples

    International Nuclear Information System (INIS)

    Hsieh, Kai-Ta; Liu, Pei-Han; Urban, Pawel L.

    2015-01-01

    Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h"−"1). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment. - Highlights: • Mass spectrometric analysis normally requires sample preparation. • Liquid–liquid extraction can isolate analytes from complex matrices. • The proposed system automates the

  5. On-line dynamic fractionation and automatic determination of inorganic phosphorous in environmental solid substrates exploiting sequential injection microcolumn extraction and flow injection analysi

    DEFF Research Database (Denmark)

    Buanuam, Janya; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified by the pa......Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified...... by the partitioning of inorganic phosphorous in agricultural soils. The on-line fractionation method capitalises on the accurate metering and sequential exposure of the various extractants to the solid sample by application of programmable flow as precisely coordinated by a syringe pump. Three different soil phase...... associations for phosphorus, that is, exchangeable, Al- and Fe-bound and Ca-bound fractions, were elucidated by accommodation in the flow manifold of the 3 steps of the Hietjles-Litjkema (HL) scheme involving the use of 1.0 M NH4Cl, 0.1 M NaOH and 0.5 M HCl, respectively, as sequential leaching reagents...

  6. Approaches for on-line coupling of extraction and chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland)

    2004-04-01

    This review provides an overview of the approaches available in order to perform on-line coupling of various extraction techniques with liquid and gas chromatography, for the analysis of semivolatile and nonvolatile analytes in liquid and solid samples. The main focus is on the instrumental set-up of these techniques. Selected real applications are described by way of illustration. The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid extraction, solid-phase extraction, membrane-based techniques, pressurised liquid extraction, supercritical fluid extraction, and microwave- and sonication-assisted extractions. The following systems are not covered in this review: on-line coupled solid-phase extraction-liquid chromatography, purge-and-trap-GC, and membrane extraction with a sorbent interface-GC. (orig.)

  7. On-line dynamic extraction and automated determination of readily bioavailable hexavalent chromium in solid substrates using micro-sequential injection bead-injection lab-on-valve hyphenated with electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    A novel and miniaturized micro-sequential injection bead injection lab-on-valve (μSI-BI-LOV) fractionation system was developed for in-line microcolumn soil extraction under simulated environmental scenarios and accurate monitoring of the content of easily mobilisable hexavalent chromium in soil...... environments at the sub-low parts-per-million level. The flow system integrates dynamic leaching of hexavalent chromium using deionized water as recommended by the German Standard DIN 38414-S4 method; on-line pH adjustment of the extract by a 0.01 mol L-1 Tris-HNO3 buffer solution; isolation of the chromate...... polluted agricultural soil material (San Joaquin Soil-Baseline Trace Element Concentrations) with water-soluble Cr(VI) salts at different concentration levels. The potential of the μSI-BI-LOV set-up with renewable surfaces for flame-AAS determination of high levels of readily bioavailable chromate...

  8. On-line control of the nonlinear dynamics for synchrotrons

    Science.gov (United States)

    Bengtsson, J.; Martin, I. P. S.; Rowland, J. H.; Bartolini, R.

    2015-07-01

    We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of "smart sextupole knobs" attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  9. On-line control of the nonlinear dynamics for synchrotrons

    Directory of Open Access Journals (Sweden)

    J. Bengtsson

    2015-07-01

    Full Text Available We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of “smart sextupole knobs” attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  10. The current role of on-line extraction approaches in clinical and forensic toxicology.

    Science.gov (United States)

    Mueller, Daniel M

    2014-08-01

    In today's clinical and forensic toxicological laboratories, automation is of interest because of its ability to optimize processes, to reduce manual workload and handling errors and to minimize exposition to potentially infectious samples. Extraction is usually the most time-consuming step; therefore, automation of this step is reasonable. Currently, from the field of clinical and forensic toxicology, methods using the following on-line extraction techniques have been published: on-line solid-phase extraction, turbulent flow chromatography, solid-phase microextraction, microextraction by packed sorbent, single-drop microextraction and on-line desorption of dried blood spots. Most of these published methods are either single-analyte or multicomponent procedures; methods intended for systematic toxicological analysis are relatively scarce. However, the use of on-line extraction will certainly increase in the near future.

  11. Determination of major aromatic constituents in vanilla using an on-line supercritical fluid extraction coupled with supercritical fluid chromatography.

    Science.gov (United States)

    Liang, Yanshan; Liu, Jiaqi; Zhong, Qisheng; Shen, Lingling; Yao, Jinting; Huang, Taohong; Zhou, Ting

    2018-04-01

    An on-line supercritical fluid extraction coupled with supercritical fluid chromatography method was developed for the determination of four major aromatic constituents in vanilla. The parameters of supercritical fluid extraction were systematically investigated using single factor optimization experiments and response surface methodology by a Box-Behnken design. The modifier ratio, split ratio, and the extraction temperature and pressure were the major parameters which have significant effects on the extraction. While the static extraction time, dynamic extraction time, and recycle time had little influence on the compounds with low polarity. Under the optimized conditions, the relative extraction efficiencies of all the constituents reached 89.0-95.1%. The limits of quantification were in the range of 1.123-4.747 μg. The limits of detection were in the range of 0.3368-1.424 μg. The recoveries of the four analytes were in the range of 76.1-88.9%. The relative standard deviations of intra- and interday precision ranged from 4.2 to 7.6%. Compared with other off-line methods, the present method obtained higher extraction yields for all four aromatic constituents. Finally, this method has been applied to the analysis of vanilla from different sources. On the basis of the results, the on-line supercritical fluid extraction-supercritical fluid chromatography method shows great promise in the analysis of aromatic constituents in natural products. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Supercritical fluid extraction-capillary gas chromatography: on-line coupling with a programmed temperature vaporizer

    NARCIS (Netherlands)

    Houben, R.J.; Janssen, J.G.M.; Leclercq, P.A.; Rijks, J.A.; Cramers, C.A.M.G.

    1990-01-01

    A simple and versatile system is described for the on-line coupling of SFE to capillary GC. The interfacing consists of a programmed temperature vaporizer (PTV) injector. With this injector it is possible to combine solute trapping, elimination of a high flow of extraction fluid, and quantitative

  13. On-line Dynamic Security Assessment in Power Systems

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel

    and solar radiation. Moreover, ongoing research suggests that demand response will be introduced to maintain power balance between generation and consumption at all times. Due to these changes the operating point of the power system will be less predictable and today’s stability and security assessment...... for early prediction of critical voltage sags is described. The method’s performance is compared to other prediction approaches. The results show that the proposed method succeeds in early, accurately and consistently predicting critically low voltage sags. An efficient on-line DSA not only identifies...

  14. Human comment dynamics in on-line social systems

    Science.gov (United States)

    Wu, Ye; Zhou, Changsong; Chen, Maoying; Xiao, Jinghua; Kurths, Jürgen

    2010-12-01

    Human comment is studied using data from ‘tianya’ which is one of the most popular on-line social systems in China. We found that the time interval between two consecutive comments on the same topic, called inter-event time, follows a power-law distribution. This result shows that there is no characteristic decay time on a topic. It allows for very long periods without comments that separate bursts of intensive comments. Furthermore, the frequency of a different ID commenting on a topic also follows a power-law distribution. It indicates that there are some “hubs” in the topic who lead the direction of the public opinion. Based on the personal comments habit, a model is introduced to explain these phenomena. The numerical simulations of the model fit well with the empirical results. Our findings are helpful for discovering regular patterns of human behavior in on-line society and the evolution of the public opinion on the virtual as well as real society.

  15. A multisyringe flow-through sequential extraction system for on-line monitoring of orthophosphate in soils and sediments

    DEFF Research Database (Denmark)

    Buanuam, Janya; Miró, Manuel; Hansen, Elo Harald

    2007-01-01

    A fully automated flow-through microcolumn fractionation system with on-line post-extraction derivatization is proposed for monitoring of orthophosphate in solid samples of environmental relevance. The system integrates dynamic sequential extraction using 1.0 mol l-1 NH4Cl, 0.1 mol l-1 NaOH and 0...... of the operational times from days to hours, highly temporal resolution of the leaching process, and the capability for immediate decision for stopping or proceeding with the ongoing extraction. Very importantly, accurate determination of the various orthophosphate pools is ensured by minimization of the hydrolysis...... of extracted organic phosphorus and condensed inorganic phosphates within the time frame of the assay. The potential of the novel system for accommodation of the harmonized protocol from the Standards, Measurement and Testing (SMT) Program of the Commission of the European Communities for inorganic phosphorus...

  16. Dynamics of user networks in on-line electronic auctions

    Czech Academy of Sciences Publication Activity Database

    Slanina, František

    2014-01-01

    Roč. 17, č. 1 (2014), "1450002-1"-"1450002-14" ISSN 0219-5259 R&D Projects: GA MŠk OC09078 Institutional support: RVO:68378271 Keywords : networks * random graphs * dynamics Subject RIV: BE - Theoretical Physics Impact factor: 0.968, year: 2014

  17. Feature Extraction in Sequential Multimedia Images: with Applications in Satellite Images and On-line Videos

    Science.gov (United States)

    Liang, Yu-Li

    Multimedia data is increasingly important in scientific discovery and people's daily lives. Content of massive multimedia is often diverse and noisy, and motion between frames is sometimes crucial in analyzing those data. Among all, still images and videos are commonly used formats. Images are compact in size but do not contain motion information. Videos record motion but are sometimes too big to be analyzed. Sequential images, which are a set of continuous images with low frame rate, stand out because they are smaller than videos and still maintain motion information. This thesis investigates features in different types of noisy sequential images, and the proposed solutions that intelligently combined multiple features to successfully retrieve visual information from on-line videos and cloudy satellite images. The first task is detecting supraglacial lakes above ice sheet in sequential satellite images. The dynamics of supraglacial lakes on the Greenland ice sheet deeply affect glacier movement, which is directly related to sea level rise and global environment change. Detecting lakes above ice is suffering from diverse image qualities and unexpected clouds. A new method is proposed to efficiently extract prominent lake candidates with irregular shapes, heterogeneous backgrounds, and in cloudy images. The proposed system fully automatize the procedure that track lakes with high accuracy. We further cooperated with geoscientists to examine the tracked lakes and found new scientific findings. The second one is detecting obscene content in on-line video chat services, such as Chatroulette, that randomly match pairs of users in video chat sessions. A big problem encountered in such systems is the presence of flashers and obscene content. Because of various obscene content and unstable qualities of videos capture by home web-camera, detecting misbehaving users is a highly challenging task. We propose SafeVchat, which is the first solution that achieves satisfactory

  18. On-line control of a liquid-liquid extraction column by the modal control method

    International Nuclear Information System (INIS)

    Bonnefoi, P.; Poujol, A.; Zwingelstein, G.; Dargier, C.; Rouyer, H.

    1977-02-01

    The application of modal analysis to the on-line control of a liquid-liquid extraction column is presented. This process is used in reprocessing for U purification. U in the aqueous acid phase is extracted by a solvent flowing at counter-current. The process is described by 4 nonlinear equations and gives the U and acid concentrations in the two phases. An approximative model is established adapted to the control of the column. Some results of a numerical simulation are given when a single mode is controled. They show that a single sensor allows a good control [fr

  19. Integrating Multiple On-line Knowledge Bases for Disease-Lab Test Relation Extraction.

    Science.gov (United States)

    Zhang, Yaoyun; Soysal, Ergin; Moon, Sungrim; Wang, Jingqi; Tao, Cui; Xu, Hua

    2015-01-01

    A computable knowledge base containing relations between diseases and lab tests would be a great resource for many biomedical informatics applications. This paper describes our initial step towards establishing a comprehensive knowledge base of disease and lab tests relations utilizing three public on-line resources. LabTestsOnline, MedlinePlus and Wikipedia are integrated to create a freely available, computable disease-lab test knowledgebase. Disease and lab test concepts are identified using MetaMap and relations between diseases and lab tests are determined based on source-specific rules. Experimental results demonstrate a high precision for relation extraction, with Wikipedia achieving the highest precision of 87%. Combining the three sources reached a recall of 51.40%, when compared with a subset of disease-lab test relations extracted from a reference book. Moreover, we found additional disease-lab test relations from on-line resources, indicating they are complementary to existing reference books for building a comprehensive disease and lab test relation knowledge base.

  20. Exploiting Sequential Injection on-line Solvent Extraction/Back Extraction with Detection by ETAAS or ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    presents an on-line SI-solvent extraction/back extraction procedure used in connection with detection by either ETAAS or ICPMS. Incorporating two newly designed dual-conical gravitational phase separators, its performance is demonstrated for the determination of various metals in reference materials.......Electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICPMS) are highly sensitive techniques for trace metal analyses. Nevertheless, separation/preconcentration procedures are often called for in order to overcome their inherent low matrix...... tolerances. With detection by ETAAS, separation/preconcentration by solvent extraction has enjoyed much use. However, this approach is not necessarily the optimal one since introduction of organic eluates directly into the graphite tube might lead to deteriorated reproducibility and lower sensitivity...

  1. Exploiting sequential injection on-line solvent extraction/back extraction with detection by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    presents an on-line SI-solvent extraction/back extraction procedure used in connection with detection by either ETAAS or ICPMS. Incorporating two newly designed dual-conical gravitational phase separators, its performance is demonstrated for the determination of various metals in reference materials.......Electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICPMS) are highly sensitive techniques for trace metal analyses. Nevertheless, separation/preconcentration procedures are often called for in order to overcome their inherent low matrix tolerance....... With detection by ETAAS, separation/preconcentration by solvent extraction has enjoyed much use. However, this approach is not necessarily the optimal one since introduction of organic eluates directly into the graphite tube might lead to deteriorated reproducibility and lower sensitivity. And for ICPMS...

  2. On-line dynamic monitoring automotive exhausts: using BP-ANN for distinguishing multi-components

    Science.gov (United States)

    Zhao, Yudi; Wei, Ruyi; Liu, Xuebin

    2017-10-01

    Remote sensing-Fourier Transform infrared spectroscopy (RS-FTIR) is one of the most important technologies in atmospheric pollutant monitoring. It is very appropriate for on-line dynamic remote sensing monitoring of air pollutants, especially for the automotive exhausts. However, their absorption spectra are often seriously overlapped in the atmospheric infrared window bands, i.e. MWIR (3 5μm). Artificial Neural Network (ANN) is an algorithm based on the theory of the biological neural network, which simplifies the partial differential equation with complex construction. For its preferable performance in nonlinear mapping and fitting, in this paper we utilize Back Propagation-Artificial Neural Network (BP-ANN) to quantitatively analyze the concentrations of four typical industrial automotive exhausts, including CO, NO, NO2 and SO2. We extracted the original data of these automotive exhausts from the HITRAN database, most of which virtually overlapped, and established a mixed multi-component simulation environment. Based on Beer-Lambert Law, concentrations can be retrieved from the absorbance of spectra. Parameters including learning rate, momentum factor, the number of hidden nodes and iterations were obtained when the BP network was trained with 80 groups of input data. By improving these parameters, the network can be optimized to produce necessarily higher precision for the retrieved concentrations. This BP-ANN method proves to be an effective and promising algorithm on dealing with multi-components analysis of automotive exhausts.

  3. Development of an on-line analyzer for organic phase uranium concentration in extraction process

    International Nuclear Information System (INIS)

    Dong Yanwu; Song Yufen; Zhu Yaokun; Cong Peiyuan; Cui Songru

    1998-10-01

    The working principle, constitution, performance of an on-line analyzer and the development characteristic of immersion sonde, data processing system and examination standard are reported. The performance of this instrument is reliable. For identical sample, the signal fluctuation in continuous monitoring for four months is less than +-1%. According to required measurement range by choosing appropriate length of sample cell the precision of measurement is better than 1% at uranium concentration 100 g/L. The detection limit is (50 +- 10) mg/L. The uranium concentration in process stream can be automatically displayed and printed out in real time and 4∼20 mA current signal being proportional to the uranium concentration can be presented. So the continuous control and computer management for the extraction process can be achieved

  4. On-line supercapacitor dynamic models for energy conversion and management

    International Nuclear Information System (INIS)

    Wu, C.H.; Hung, Y.H.; Hong, C.W.

    2012-01-01

    Highlights: ► On-line supercapacitor dynamic models are derived from time and frequency domains. ► Equivalent circuits with an ANN identifier are derived for nonlinear effects. ► Nonlinear effects include environmental temperature and operating voltage. ► Supercapacitor models can achieve both system fidelity and computation efficiency. - Abstract: This paper develops on-line nonlinear dynamic models of electrochemical supercapacitors which are for energy conversion and management. Based on the theory of electrochemical impedance spectroscopy, extensive alternative current impedance tests have been conducted to investigate the frequency-domain dynamics of these supercapacitors. A Nyquist diagram is plotted to help establish an equivalent electric circuit, which is regarded as the first-phase linear model. Two performance-influencing factors, environmental temperature and operating voltage, are considered as nonlinear effects. The nonlinear relationships among parameters of the capacitances and resistances in the first-phase model are established by a multi-layer artificial neural network. The neural parameters are trained using a back-propagation algorithm by feeding the experimental data bank. Combining the first-phase model and the on-line neural “parameter identifier”, the algorithm produces an on-line nonlinear dynamic model. Simulation results have proved that this proposed model is able to achieve both system fidelity and computational efficiency.

  5. On-line supercritical fluid extraction-supercritical fluid chromatography-mass spectrometry of polycyclic aromatic hydrocarbons in soil.

    Science.gov (United States)

    Wicker, A Paige; Carlton, Doug D; Tanaka, Kenichiro; Nishimura, Masayuki; Chen, Vivian; Ogura, Tairo; Hedgepeth, William; Schug, Kevin A

    2018-06-01

    On-line supercritical fluid extraction - supercritical fluid chromatography - mass spectrometry (SFE-SFC-MS) has been applied for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil. The purpose of this study was to develop and validate the first on-line SFE-SFC-MS method for the quantification of PAHs in various types of soil. By coupling the sample extraction on-line with chromatography and detection, sample preparation is minimized, diminishing sample loss and contamination, and significantly decreasing the required extraction time. Parameters for on-line extraction coupled to chromatographic analysis were optimized. The method was validated for concentrations of 10-1500 ng of PAHs per gram of soil in Certified Reference Material (CRM) sediment, clay, and sand with R 2  ≥ 0.99. Limits of detection (LOD) were found in the range of 0.001-5 ng/g, and limits of quantification (LOQ) in the range of 5-15 ng/g. The method developed in this study can be effectively applied to the study of PAHs in the environment, and may lay the foundation for further applications of on-line SFE-SFC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Vehicle Dynamic Prediction Systems with On-Line Identification of Vehicle Parameters and Road Conditions

    Science.gov (United States)

    Hsu, Ling-Yuan; Chen, Tsung-Lin

    2012-01-01

    This paper presents a vehicle dynamics prediction system, which consists of a sensor fusion system and a vehicle parameter identification system. This sensor fusion system can obtain the six degree-of-freedom vehicle dynamics and two road angles without using a vehicle model. The vehicle parameter identification system uses the vehicle dynamics from the sensor fusion system to identify ten vehicle parameters in real time, including vehicle mass, moment of inertial, and road friction coefficients. With above two systems, the future vehicle dynamics is predicted by using a vehicle dynamics model, obtained from the parameter identification system, to propagate with time the current vehicle state values, obtained from the sensor fusion system. Comparing with most existing literatures in this field, the proposed approach improves the prediction accuracy both by incorporating more vehicle dynamics to the prediction system and by on-line identification to minimize the vehicle modeling errors. Simulation results show that the proposed method successfully predicts the vehicle dynamics in a left-hand turn event and a rollover event. The prediction inaccuracy is 0.51% in a left-hand turn event and 27.3% in a rollover event. PMID:23202231

  7. Dynamic evolving spiking neural networks for on-line spatio- and spectro-temporal pattern recognition.

    Science.gov (United States)

    Kasabov, Nikola; Dhoble, Kshitij; Nuntalid, Nuttapod; Indiveri, Giacomo

    2013-05-01

    On-line learning and recognition of spatio- and spectro-temporal data (SSTD) is a very challenging task and an important one for the future development of autonomous machine learning systems with broad applications. Models based on spiking neural networks (SNN) have already proved their potential in capturing spatial and temporal data. One class of them, the evolving SNN (eSNN), uses a one-pass rank-order learning mechanism and a strategy to evolve a new spiking neuron and new connections to learn new patterns from incoming data. So far these networks have been mainly used for fast image and speech frame-based recognition. Alternative spike-time learning methods, such as Spike-Timing Dependent Plasticity (STDP) and its variant Spike Driven Synaptic Plasticity (SDSP), can also be used to learn spatio-temporal representations, but they usually require many iterations in an unsupervised or semi-supervised mode of learning. This paper introduces a new class of eSNN, dynamic eSNN, that utilise both rank-order learning and dynamic synapses to learn SSTD in a fast, on-line mode. The paper also introduces a new model called deSNN, that utilises rank-order learning and SDSP spike-time learning in unsupervised, supervised, or semi-supervised modes. The SDSP learning is used to evolve dynamically the network changing connection weights that capture spatio-temporal spike data clusters both during training and during recall. The new deSNN model is first illustrated on simple examples and then applied on two case study applications: (1) moving object recognition using address-event representation (AER) with data collected using a silicon retina device; (2) EEG SSTD recognition for brain-computer interfaces. The deSNN models resulted in a superior performance in terms of accuracy and speed when compared with other SNN models that use either rank-order or STDP learning. The reason is that the deSNN makes use of both the information contained in the order of the first input spikes

  8. On-line Incorporation of Cloud Point Extraction in Flame Atomic Absorption Spectrometric Determination of Silver

    OpenAIRE

    DALALI, Nasser; JAVADI, Nasrin; AGRAWAL, Yadvendra KUMAR

    2008-01-01

    A cloud point extraction method was incorporated into a flow injection system, coupled with flame atomic absorption spectrometry, for determination of trace amounts of silver. The analyte in the aqueous solution was acidified with 0.2 mol L-1 sulfuric acid and complexed with dithizone. The cloud point extraction was performed using the non-ionic surfactant Triton X-114. After obtaining the cloud point, the surfactant-rich phase containing the dithizonate complex was collected in a m...

  9. Dynamic neural networks based on-line identification and control of high performance motor drives

    Science.gov (United States)

    Rubaai, Ahmed; Kotaru, Raj

    1995-01-01

    In the automated and high-tech industries of the future, there wil be a need for high performance motor drives both in the low-power range and in the high-power range. To meet very straight demands of tracking and regulation in the two quadrants of operation, advanced control technologies are of a considerable interest and need to be developed. In response a dynamics learning control architecture is developed with simultaneous on-line identification and control. the feature of the proposed approach, to efficiently combine the dual task of system identification (learning) and adaptive control of nonlinear motor drives into a single operation is presented. This approach, therefore, not only adapts to uncertainties of the dynamic parameters of the motor drives but also learns about their inherent nonlinearities. In fact, most of the neural networks based adaptive control approaches in use have an identification phase entirely separate from the control phase. Because these approaches separate the identification and control modes, it is not possible to cope with dynamic changes in a controlled process. Extensive simulation studies have been conducted and good performance was observed. The robustness characteristics of neuro-controllers to perform efficiently in a noisy environment is also demonstrated. With this initial success, the principal investigator believes that the proposed approach with the suggested neural structure can be used successfully for the control of high performance motor drives. Two identification and control topologies based on the model reference adaptive control technique are used in this present analysis. No prior knowledge of load dynamics is assumed in either topology while the second topology also assumes no knowledge of the motor parameters.

  10. On-line gross alpha radiation monitoring of natural waters with extractive scintillating resins

    International Nuclear Information System (INIS)

    Hughes, Lara; De Vol, T.A.

    2003-01-01

    Extractive scintillating resins, which are used to simultaneously separate and quantify radioactivity in aqueous solutions, were developed for low-level alpha radiation monitoring of natural waters. Resins were investigated with bis(2-ethylhexyl)methane-diphosphonic acid (H 2 DEH[MDP], Dipex[reg]) extractant, which has a strong affinity for tri-, tetra- and hexavalent actinides in dilute acids. Extractive scintillating resins were manifested (1) as a mixed bed of scintillating resin and extraction chromatographic resin and (2) by diffusing the organic fluor 2-(1-naphtyl)-5-phenyloxazole into macroporous polystyrene chromatographic resin, then coating with H 2 DEH[MDP], or by coating H 2 DEH[MDP] on scintillating polyvinyltoluene beads. The scintillation light was detected with a modified Hidex Triathler to allow for continuous flow measurements. The average detection efficiencies were 51.7±2.6% and 65.8±10.1% for natural uranium and 241 Am, respectively, for the extractant coated scintillator. The resin was stable for solution flow of up to 1000 ml resulting in rapid real-time quantification of natural uranium in groundwater down to 30 μg/ml

  11. Development of a Probabilistic Technique for On-line Parameter and State Estimation in Non-linear Dynamic Systems

    International Nuclear Information System (INIS)

    Tunc Aldemir; Miller, Don W.; Hajek, Brian K.; Peng Wang

    2002-01-01

    The DSD (Dynamic System Doctor) is a system-independent, interactive software under development for on-line state/parameter estimation in dynamic systems (1), partially supported through a Nuclear Engineering Education (NEER) grant during 1998-2001. This paper summarizes the recent accomplishments in improving the user-friendliness and computational capability of DSD

  12. Technical note: New applications for on-line automated solid phase extraction

    OpenAIRE

    MacFarlane, John D.

    1997-01-01

    This technical note explains the disadvantages of manual solid phase extraction (SPE) techniques and the benefits to be gained with automatic systems. The note reports on a number of general and highly specific applications using the Sample Preparation Unit OSP-2A.

  13. On-line lab-in-syringe cloud point extraction for the spectrophotometric determination of antimony.

    Science.gov (United States)

    Frizzarin, Rejane M; Portugal, Lindomar A; Estela, José M; Rocha, Fábio R P; Cerdà, Victor

    2016-02-01

    Most of the procedures for antimony determination require time-consuming sample preparation (e.g. liquid-liquid extraction with organic solvents), which are harmful to the environment. Because of the high antimony toxicity, a rapid, sensitive and greener procedure for its determination becomes necessary. The goal of this work was to develop an analytical procedure exploiting for the first time the cloud point extraction on a lab-in-syringe flow system aiming at the spectrophotometric determination of antimony. The procedure was based on formation of an ion-pair between the antimony-iodide complex and H(+) followed by extraction with Triton X-114. The factorial design showed that the concentrations of ascorbic acid, H2SO4 and Triton X-114, as well as second and third order interactions were significant at the 95% confidence level. A Box-Behnken design was applied to obtain the response surfaces and to identify the critical values. System is robust at the 95% confidence level. A linear response was observed from 5 to 50 µg L(-1), described by the equation A=0.137+0.050C(Sb) (r=0.998). The detection limit (99.7% confidence level), the coefficient of variation (n=5; 15 µg L(-1)) and the sampling rate was estimated at 1.8 µg L(-1), 1.6% and 16 h(-1), respectively. The procedure allows quantification of antimony in the concentrations established by environmental legislation (6 µg L(-1)) and it was successfully applied to the determination of antimony in freshwater samples and antileishmanial drugs, yielding results in agreement with those obtained by HGFAAS at the 95% confidence level. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for determination of trace levels of copper and lead via solvent extraction/back extraction coupled to ICP-MS is described. In citrate buffer of pH 3, neutral complexes between the analytes and the chelating reagent, ammonium...... loop, the content of which is subsequently introduced into the ICP-MS, via a direct injection high efficiency nebulizer (DIHEN), for quantification. Enrichment factors of 29.6 (Cu) and 23.3 (Pb), detection limits of 17 ng/l (Cu) and 11 ng/l (Pb), along with a sampling frequency of 13 s/h were obtained...

  15. Improving the On-Line Extraction of Polar Compounds by IT-SPME with Silica Nanoparticles Modified Phases

    Directory of Open Access Journals (Sweden)

    Pascual Serra-Mora

    2018-02-01

    Full Text Available In the present work the extraction efficiency of in-tube solid-phase microextraction (IT-SPME for polar herbicides has been evaluated using extractive capillaries coated with different polymeric sorbents. For this purpose, aqueous solutions of herbicides with a wide range of polarities, including some highly polar compounds (log Kow < 1, have been directly processed by IT-SPME coupled on-line to capillary liquid chromatography with UV-diode array detection. For extraction, commercially available capillary columns coated with polydimethylsiloxane (PDMS and polyetilenglicol (PEG-based phases have been used, and the results have been compared with those obtained with a synthesized tetraethyl orthosilicate (TEOS-trimethoxyethylsilane (MTEOS polymer, as well as the same polymer reinforced with silica nanoparticles (SiO2 NPs. The SiO2 NPs functionalized TEOS-MTEOS coating provided the best results for most herbicides, especially for the most polar compounds. On the basis of the results obtained, conditions for the quantification of the herbicides tested are described using a SiO2 NPs reinforced TEOS-MTEOS coated capillary. The proposed method provided satisfactory linearity up to concentrations of 200 μg/L. The precision was also suitable, with relative standard deviations (RSDs values ≤9% (n = 3, and the limits of detection (LODs were within the 0.5–7.5 µg/L range. The method has been applied to different water samples and the extract obtained from an agricultural soil.

  16. Preliminary studies of using preheated carrier gas for on-line membrane extraction of semivolatile organic compounds.

    Science.gov (United States)

    Liu, Xinyu; Pawliszyn, Janusz

    2007-04-01

    In this paper, we present results for the on-line determination of semivolatile organic compounds (SVOCs) in air using membrane extraction with a sorbent interface-ion mobility spectrometry (MESI-IMS) system with a preheated carrier (stripping) gas. The mechanism of the mass transfer of SVOCs across a membrane was initially studied. In comparison with the extraction of volatile analytes, the mass transfer resistance that originated from the slow desorption from the internal membrane surface during the SVOC extraction processes should be taken into account. A preheated carrier gas system was therefore built to facilitate desorption of analytes from the internal membrane surface. With the benefit of a temperature gradient existing between the internal and external membrane surfaces, an increase in the desorption rate of a specific analyte at the internal surface and the diffusion coefficient within the membrane could be achieved while avoiding a decrease of the distribution constant on the external membrane interface. This technique improved both the extraction rate and response times of the MESI-IMS system for the analysis of SVOCs. Finally, the MESI-IMS system was shown to be capable of on-site measurement by monitoring selected polynuclear aromatic hydrocarbons emitted from cigarette smoke.

  17. Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching

    Science.gov (United States)

    Song, Q.; Putcha, L.; Harm, D. L. (Principal Investigator)

    2001-01-01

    A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.

  18. On-line caloric value sensor and validation of dynamic models applied to municipal solid waste

    NARCIS (Netherlands)

    Kessel, van L.B.M.; Leskens, M.; Brem, G.

    2002-01-01

    This paper deals with two aspects concerning the optimization of municipal solid waste combustion (MSWC) processes. First of all, an on-line calorific value sensor is discussed by means of which the calorific value of the waste can be estimated from actual process data. Experimental results on a

  19. Development of an on-line high performance liquid chromatography detection system for human cytochrome P450 1A2 inhibitors in extracts of natural products

    NARCIS (Netherlands)

    Jeurissen, S.M.F.; Claassen, F.W.; Havlik, J.; Bouwmans, E.E.; Cnubben, N.H.P.; Sudhölter, E.J.R.; Rietjens, I.M.C.M.; Beek, T.A. van

    2007-01-01

    An on-line HPLC screening method for detection of inhibitors of human cytochrome P450 1A2 in extracts was developed. HPLC separation of extracts is connected to a continuous methoxyresorufin-O-demethylation (MROD) assay in which recombinant human P450 1A2 converts methoxyresorufin to its fluorescent

  20. Accelerated solvent extraction followed by on-line solid-phase extraction coupled to ion trap LC/MS/MS for analysis of benzalkonium chlorides in sediment samples

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2002-01-01

    Benzalkonium chlorides (BACs) were successfully extracted from sediment samples using a new methodology based on accelerated solvent extraction (ASE) followed by an on-line cleanup step. The BACs were detected by liquid chromatography/ion trap mass spectrometry (LC/MS) or tandem mass spectrometry (MS/MS) using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the high sensitivity offered by the ion trap MS/MS. The effects of solvent type and ASE operational variables, such as temperature and pressure, were evaluated. After optimization, a mixture of acetonitrile/water (6:4 or 7:3) was found to be most efficient for extracting BACs from the sediment samples. Extraction recoveries ranged from 95 to 105% for C12 and C14 homologues, respectively. Total method recoveries from fortified sediment samples, using a cleanup step followed by ASE, were 85% for C12BAC and 79% for C14-BAC. The methodology developed in this work provides detection limits in the subnanogram per gram range. Concentrations of BAC homologues ranged from 22 to 206 ??g/kg in sediment samples from different river sites downstream from wastewater treatment plants. The high affinity of BACs for soil suggests that BACs preferentially concentrate in sediment rather than in water.

  1. Flow injection microfluidic device with on-line fluorescent derivatization for the determination of Cr(III) and Cr(VI) in water samples after solid phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Guilong [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China); He, Qiang, E-mail: heqiang0980@163.com [Key Laboratory of Eco-Environment of Three Gorges Region of Ministry of Education, Chongqing University, Chongqing, 400045 (China); Lu, Ying [Department of Mathematics and Physics, Armed Police College, Chengdu, 610213 (China); Huang, Jing [Research Center for Advanced Computation, College of Science, Xihua University, Chengdu, 610039 (China); Lin, Jin-Ming, E-mail: jmlin@mail.tsinghua.edu.cn [Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Tsinghua University, Beijing, 100084 (China)

    2017-02-22

    In this paper, a rapid and simple method using magnetic multi-walled carbon nanotubes (MWCNTS), as a solid-phase extraction (SPE) sorbent, was successfully developed for extraction and preconcentration trace amounts of Cr(III) in water samples. The synthesized magnetic-MWCNTs nanocomposite was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). A rhodamine derivative (R1) was synthesized and characterized as a highly selective and sensitive fluorescent derivatizing agent for Cr(III). After SPE procedure, Cr(III) analysis was performed by flow injection microfluidic chip with on-line fluorescent derivatization and laser-induced fluorescence (LIF) spectroscopy detection. The parameters, which affected the efficiency of the developed method were investigated and optimized. Under the optimized conditions, the method exhibited a linear dynamic range of 0–10.0 nM, with a detection limit of 0.094 nM and an enrichment factor of 38. Furthermore, real water samples were analyzed and good recoveries were obtained from 91.0 to 101.6%. - Graphical abstract: Flow injection microfluidic device with on-line fluorescent derivatization and detection coupled to LIF. - Highlights: • A highly selective and sensitive derivatizing reagent for Cr(III) was synthesized and characterized. • The magnetic-MWCNTs nanocomposite as a SPE sorbent was successfully synthesized and characterized. • A new portable detection system was developed for microfluidic chip FIA platform.

  2. Dynamics of Agricultural Groundwater Extraction

    NARCIS (Netherlands)

    Hellegers, P.J.G.J.; Zilberman, D.; Ierland, van E.C.

    2001-01-01

    Agricultural shallow groundwater extraction can result in desiccation of neighbouring nature reserves and degradation of groundwater quality in the Netherlands, whereas both externalities are often not considered when agricultural groundwater extraction patterns are being determined. A model is

  3. Analysis of microcontaminants in aqueous samples by fully automated on-line solid-phase extraction-gas chromatography-mass selective detection.

    NARCIS (Netherlands)

    Louter, A.J.H.; van Beekvelt, C.A.; Cid Montanes, P.; Slobodník, J.; Vreuls, J.J.; Brinkman, U.A.T.

    1996-01-01

    The trace-level analysis of unknown organic pollutants in water requires the use of fast and sensitive methods which also provide structural information. In the present study, an on-line technique was used which combines sample preparation by means of solid-phase extraction (SPE) on a small

  4. Determination of inorganic arsenic in algae using bromine halogenation and on-line nonpolar solid phase extraction followed by hydride generation atomic flourescence spectrometry

    Science.gov (United States)

    Accurate, stable and fast analysis of toxic inorganic arsenic (iAs) in complicated and arsenosugar-rich algae matrix is always a challenge. Herein, a novel analytical method for iAs in algae was reported, using bromine halogenation and on-line nonpolar solid phase extraction (SPE) followed by hydrid...

  5. Data correlation in on-line solid-phase extraction-gas chromatography-atomic emission/mass spectrometric detection of unknown microcontaminants

    NARCIS (Netherlands)

    Hankemeier, Th.; Rozenbrand, J.; Abhadur, M.; Vreuls, J.J.; Brinkman, U.A.Th.

    1998-01-01

    A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC

  6. An LC-MS Assay with Isocratic Separation and On-Line Solid Phase Extraction to Improve the Routine Therapeutic Drug Monitoring of Busulfan in Plasma

    Directory of Open Access Journals (Sweden)

    Ialongo Cristiano

    2017-04-01

    Full Text Available Background: Busulfan (Bu requires therapeutic drug monitoring (TDM in subjects undergoing a conditioning regimen for hematopoietic stem cell transplantation (HSCT. To speed up the procedure and increase reproducibility, we improved our routine LC-MS/MS assay using the on-line solid-phase extraction (SPE of samples.

  7. Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography.

    Science.gov (United States)

    Lhotská, Ivona; Holznerová, Anežka; Solich, Petr; Šatínský, Dalibor

    2017-12-01

    Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Supercritical fluid extraction (SFE) of ketamine metabolites from dried urine and on-line quantification by supercritical fluid chromatography and single mass detection (on-line SFE-SFC-MS).

    Science.gov (United States)

    Hofstetter, Robert; Fassauer, Georg M; Link, Andreas

    2018-02-15

    On-line solid-phase supercritical fluid extraction (SFE) and chromatography (SFC) coupled to mass spectrometry (MS) has been evaluated for its usefulness with respect to metabolic profiling and pharmacological investigations of ketamine in humans. The aim of this study was to develop and validate a rapid, highly selective and sensitive SFE-SFC-MS method for the quantification of ketamine and its metabolites in miniature amounts in human urine excluding liquid-liquid extraction (LLE). Several conditions were optimized systematically following the requirements of the European Medicines Agency: selectivity, carry-over, calibration curve parameters (LLOQ, range and linearity), within- and between-run accuracy and precision, dilution integrity, matrix effect, and stability. The method, which required a relatively small volume of human urine (20 μL per sample), was validated for pharmacologically and toxicologically relevant concentrations ranging from 25.0 to 1000 ng/mL (r 2  > 0.995). The lower limit of quantification (LLOQ) for all compounds was found to be as low as 0.5 ng. In addition, stability of analytes during removal of water from the urine samples using different conditions (filter paper or ISOLUTE® HM-N) was studied. In conclusion, the method developed in this study can be successfully applied to studies of ketamine metabolites in humans, and may pave the way for routine application of on-line SFE-SFC-MS in clinical investigations. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Speciation analysis of inorganic arsenic by magnetic solid phase extraction on-line with inductively coupled mass spectrometry determination.

    Science.gov (United States)

    Montoro Leal, P; Vereda Alonso, E; López Guerrero, M M; Cordero, M T Siles; Cano Pavón, J M; García de Torres, A

    2018-07-01

    Arsenic, one of the main environmental pollutants and potent natural poison, is a chemical element that is spread throughout the Earth's crust. It is well known that the toxicity of arsenic is highly dependent on its chemical forms. Generally, the inorganic species are more toxic than its organics forms, and As(III) is 60 times more toxic than As(V). In environmental waters, arsenic exists predominantly in two chemical forms: As(III) and As(V). In view of these facts, fast, sensitive, accurate and simple analytical methods for the speciation of inorganic arsenic in environmental waters are required. In this work, a new magnetic solid phase extraction with a hydride generation system was coupled on line with inductively coupled plasma mass spectrometry (MSPE-HG-ICP-MS). The new system was based on the retention of As(III) and As(V) in two knotted reactors filled with (Fe 3 O 4 ) magnetic nanoparticles functionalized with [1,5-bis (2-pyridyl) 3-sulfophenylmethylene] thiocarbonohydrazide (PSTH-MNPs). As(III) and total inorganic As were sequentially eluted in different reduction conditions. The concentration of As(V) was obtained by subtracting As(III) from total As. The system runs in a fully automated way and the method has proved to have a wide linear range and to be precise, sensitive and fast. The detection limits found were 2.7 and 3.2 ng/L for As(III) and total As, respectively; with relative standard deviations (RSDs) of 2.5% and 2.7% and a sample throughput of 14.4 h -1 . In order to validate the developed method, several certified reference samples of environmental waters including sea water, were analyzed and the determined values were in good agreement with the certified values. The proposed method was successfully applied to the speciation analysis of inorganic arsenic in well-water and sea water. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. An On-Line Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Perfluoroalkyl Acids in Drinking and Surface Waters

    Directory of Open Access Journals (Sweden)

    Michela Mazzoni

    2015-01-01

    Full Text Available An UHPLC-MS/MS multiresidue method based on an on-line solid phase extraction (SPE procedure was developed for the simultaneous determination of 9 perfluorinated carboxylates (from 4 to 12 carbon atoms and 3 perfluorinated sulphonates (from 4 to 8 carbon atoms. This work proposes using an on-line solid phase extraction before chromatographic separation and analysis to replace traditional methods of off-line SPE before direct injection to LC-MS/MS. Manual sample preparation was reduced to sample centrifugation and acidification, thus eliminating several procedural errors and significantly reducing time-consuming and costs. Ionization suppression between target perfluorinated analytes and their coeluting SIL-IS were detected for homologues with a number of carbon atoms less than 9, but the quantitation was not affected. Total matrix effect corrected by SIL-IS, inclusive of extraction efficacy, and of ionization efficiency, ranged between −34 and +39%. The percentage of recoveries, between 76 and 134%, calculated in different matrices (tap water and rivers impacted by different pollutions was generally satisfactory. LODs and LOQs of this on-line SPE method, which also incorporate recovery losses, ranged from 0.2 to 5.0 ng/L and from 1 to 20 ng/L, respectively. Validated on-line SPE-LC/MS/MS method has been applied in a wide survey for the determination of perfluoroalkyl acids in Italian surface and ground waters.

  11. An On-Line Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Perfluoroalkyl Acids in Drinking and Surface Waters

    Science.gov (United States)

    Mazzoni, Michela; Rusconi, Marianna; Valsecchi, Sara; Martins, Claudia P. B.; Polesello, Stefano

    2015-01-01

    An UHPLC-MS/MS multiresidue method based on an on-line solid phase extraction (SPE) procedure was developed for the simultaneous determination of 9 perfluorinated carboxylates (from 4 to 12 carbon atoms) and 3 perfluorinated sulphonates (from 4 to 8 carbon atoms). This work proposes using an on-line solid phase extraction before chromatographic separation and analysis to replace traditional methods of off-line SPE before direct injection to LC-MS/MS. Manual sample preparation was reduced to sample centrifugation and acidification, thus eliminating several procedural errors and significantly reducing time-consuming and costs. Ionization suppression between target perfluorinated analytes and their coeluting SIL-IS were detected for homologues with a number of carbon atoms less than 9, but the quantitation was not affected. Total matrix effect corrected by SIL-IS, inclusive of extraction efficacy, and of ionization efficiency, ranged between −34 and +39%. The percentage of recoveries, between 76 and 134%, calculated in different matrices (tap water and rivers impacted by different pollutions) was generally satisfactory. LODs and LOQs of this on-line SPE method, which also incorporate recovery losses, ranged from 0.2 to 5.0 ng/L and from 1 to 20 ng/L, respectively. Validated on-line SPE-LC/MS/MS method has been applied in a wide survey for the determination of perfluoroalkyl acids in Italian surface and ground waters. PMID:25834752

  12. Development of an on-line mixed-mode gel liquid chromatography×reversed phase liquid chromatography method for separation of water extract from Flos Carthami.

    Science.gov (United States)

    Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun

    2017-10-13

    A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Beyond the electronic textbook model: software techniques to make on-line educational content dynamic.

    Science.gov (United States)

    Frank, M S; Dreyer, K

    2001-06-01

    . This technology enables the educator to choreograph a stylized, interactive delivery of his or her message using multimedia components assembled in virtually any order, spanning any number of web pages for a given case or theme. An educator can thus exercise precise influence on specific learning objectives, embody his or her personal teaching style within the content, and ultimately enhance its educational impact. The described technology amplifies the efforts of the educator and provides a more dynamic and enriching learning environment for web-based education.

  14. Fractionation of plutonium in environmental and bio-shielding concrete samples using dynamic sequential extraction

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin

    2010-01-01

    Fractionation of plutonium isotopes (238Pu, 239,240Pu) in environmental samples (i.e. soil and sediment) and bio-shielding concrete from decommissioning of nuclear reactor were carried out by dynamic sequential extraction using an on-line sequential injection (SI) system combined with a specially...

  15. Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection (SI) on-line solvent extraction-back extraction separation/preconcentration procedure is described. Demonstrated for the assay of cadmium by electrothermal atomic absorption spectrometry (ETAAS), the analyte is initially complexed with ammonium pyrrolidinedithioc......An automated sequential injection (SI) on-line solvent extraction-back extraction separation/preconcentration procedure is described. Demonstrated for the assay of cadmium by electrothermal atomic absorption spectrometry (ETAAS), the analyte is initially complexed with ammonium....../preconcentration process of the ensuing sample. An enrichment factor of 21.4, a detection limit of 2.7 ng/l, along with a sampling frequency of 13s/h were obtained at a sample flow rate of 6.0mlmin/sup -1/. The precision (R.S.D.) at the 0.4 mug/l level was 1.8% as compared to 3.2% when quantifying the organic extractant...

  16. On-line monitoring the extract process of Fu-fang Shuanghua oral solution using near infrared spectroscopy and different PLS algorithms

    Science.gov (United States)

    Kang, Qian; Ru, Qingguo; Liu, Yan; Xu, Lingyan; Liu, Jia; Wang, Yifei; Zhang, Yewen; Li, Hui; Zhang, Qing; Wu, Qing

    2016-01-01

    An on-line near infrared (NIR) spectroscopy monitoring method with an appropriate multivariate calibration method was developed for the extraction process of Fu-fang Shuanghua oral solution (FSOS). On-line NIR spectra were collected through two fiber optic probes, which were designed to transmit NIR radiation by a 2 mm flange. Partial least squares (PLS), interval PLS (iPLS) and synergy interval PLS (siPLS) algorithms were used comparatively for building the calibration regression models. During the extraction process, the feasibility of NIR spectroscopy was employed to determine the concentrations of chlorogenic acid (CA) content, total phenolic acids contents (TPC), total flavonoids contents (TFC) and soluble solid contents (SSC). High performance liquid chromatography (HPLC), ultraviolet spectrophotometric method (UV) and loss on drying methods were employed as reference methods. Experiment results showed that the performance of siPLS model is the best compared with PLS and iPLS. The calibration models for AC, TPC, TFC and SSC had high values of determination coefficients of (R2) (0.9948, 0.9992, 0.9950 and 0.9832) and low root mean square error of cross validation (RMSECV) (0.0113, 0.0341, 0.1787 and 1.2158), which indicate a good correlation between reference values and NIR predicted values. The overall results show that the on line detection method could be feasible in real application and would be of great value for monitoring the mixed decoction process of FSOS and other Chinese patent medicines.

  17. Rapid Determination of Two Triterpenoid Acids in Chaenomelis Fructus Using Supercritical Fluid Extraction On-line Coupled with Supercritical Fluid Chromatography.

    Science.gov (United States)

    Zhang, Xiaotian; Ji, Feng; Li, Yueqi; He, Tian; Han, Ya; Wang, Daidong; Lin, Zongtao; Chen, Shizhong

    2018-01-01

    In this study, an on-line supercritical fluid extraction (SFE) and supercritical fluid chromatography (SFC) method was developed for the rapid determination of oleanoic acid and ursolic acid in Chaenomelis Fructus. After optimization of the conditions, the two triterpenoid acids was obtained by SFE using 20% methanol as a modifier at 35°C in 8 min. They were resolved on a Shim-pack UC-X Diol column (4.6 × 150 mm, 3 μm) in 14 min (0 - 10 min, 5 - 10%; 10 - 14 min, 10% methanol in CO 2 ) with a backpressure of 15 MPa at 40°C. The on-line SFE-SFC method could be completed within 40 min (10.79 mg/g dry plant, R s = 2.36), while the ultrasound-assisted extraction and HPLC method required at least 90 min (3.55 mg/g dry plant, R s = 1.92). This on-line SFE-SFC method is powerful to simplify the pre-processing and quantitative analysis of natural products.

  18. On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination

    Energy Technology Data Exchange (ETDEWEB)

    Mitani, Constantina [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece); Anthemidis, Aristidis N., E-mail: anthemid@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece)

    2013-04-10

    Highlights: ► Drop-in-plug micro-extraction based on SI-LAV platform for metal preconcentration. ► Automatic liquid phase micro-extraction coupled with FAAS. ► Organic solvents with density higher than water are used. ► Lead determination in environmental water and urine samples. -- Abstract: A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve (LAV) platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry (FAAS), the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. A hydrophobic complex of lead with ammonium pyrrolidine dithiocarbamate (APDC) was formed on-line and subsequently extracted into an 80 μL plug of chloroform. The extraction procedure was performed by forming micro-droplets of aqueous phase into the plug of the extractant. All critical parameters that affect the efficiency of the system were studied and optimized. The proposed method offered good performance characteristics and high preconcentration ratios. For 10 mL sample consumption an enhancement factor of 125 was obtained. The detection limit was 1.8 μg L{sup −1} and the precision expressed as relative standard deviation (RSD) at 50.0 μg L{sup −1} of lead was 2.9%. The proposed method was evaluated by analyzing certified reference materials and applied for lead determination in natural waters and urine samples.

  19. High-Efficiency On-Line Solid-Phase Extraction Coupling to 15-150 um I.D. Column Liquid Chromatography for Proteomic Analysis

    International Nuclear Information System (INIS)

    Shen, Yufeng; Moore, Ronald J.; Zhao, Rui; Blonder, Josip; Auberry, Deanna L.; Masselon, Christophe D.; Pasa Tolic, Ljiljana; Hixson, Kim K.; Auberry, Kenneth J.; Smith, Richard D.

    2003-01-01

    Flexible manipulation of various properties of proteomic samples is important for proteomic analyses, but it has been little explored for newly developed approaches based on liquid chromatography (LC) in combination with mass spectrometry (MS). With miniaturization of the LC column inner diameter dimensions (required for improving the analysis sensitivity), this issue becomes more challenging due to the small flow rates and the increasing effects of extra column volume on the separation quality and its use for resolving complex proteomic mixtures. In this study, we used commercial switching valves (150-mm channels) to implement the on-line coupling of capillary LC columns with relatively large solid phase extraction (SPE) columns operated at 10,000 psi. With optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained with peak capacities of ∼1000 for capillaries having inner diameters between 15 to 150 mm. The on-line coupled SPE columns increased the sample processing capabilities by ∼400-fold for sample solution volume and ∼10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Used with an ion trap tandem MS we could typically identify 1100-1500 peptides for analyses in a single 5-hour run. Peptides extracted on the SPE column and eluted from the LC column covered a hydrophilicity/hydrophobicity range that include an estimated ∼98% of all the tryptic peptides. The present implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for routine proteomic analyses.

  20. On-line separation of Pu(III) and Am(III) using extraction and ion chromatography

    International Nuclear Information System (INIS)

    Jernstroem, J.; Lehto, J.; Betti, M.

    2007-01-01

    An on-line method developed for separating plutonium and americium was developed. The method is based on the use of HPLC pump with three analytical chromatographic columns. Plutonium is reduced throughout the procedure to trivalent oxidation state, and is recovered in the various separation steps together with americium. Light lanthanides and trivalent actinides are separated with TEVA resin in thiocyanate/formic acid media. Trivalent plutonium and americium are pre-concentrated in a TCC-II cation-exchange column, after which the separation is performed in CS5A ion chromatography column by using two different eluents. Pu(III) is eluted with a dipicolinic acid eluent, and Am(III) with oxalic acid eluent. Radiochemical and chemical purity of the eluted plutonium and americium fractions were ensured with alpha-spectrometry. (author)

  1. Feature extraction for dynamic integration of classifiers

    NARCIS (Netherlands)

    Pechenizkiy, M.; Tsymbal, A.; Puuronen, S.; Patterson, D.W.

    2007-01-01

    Recent research has shown the integration of multiple classifiers to be one of the most important directions in machine learning and data mining. In this paper, we present an algorithm for the dynamic integration of classifiers in the space of extracted features (FEDIC). It is based on the technique

  2. Quantitative analysis of higher hydrocarbons in natural gas using coupled solid-phase extraction / supercritiacal fluid extraction with on-line GC analysis

    NARCIS (Netherlands)

    Janssen, J.G.M.; Cramers, C.A.M.G.; Meulen-Kuijk, van der L.; Smit, A.L.C.; Sandra, P.; Devos, G.

    1993-01-01

    Characterisation of natural gas with respect to the hydrocarbon content is a challenging analytical problem due to the extremely low concentrations and the complexity of the matrix. In this publication a method is described for fully on-line preconcentration and analysis of n-nonane and higher

  3. Homogenate-assisted Vacuum-powered Bubble Extraction of Moso Bamboo Flavonoids for On-line Scavenging Free Radical Capacity Analysis.

    Science.gov (United States)

    Sun, Yinnan; Yang, Kui; Cao, Qin; Sun, Jinde; Xia, Yu; Wang, Yinhang; Li, Wei; Ma, Chunhui; Liu, Shouxin

    2017-07-11

    A homogenate-assisted vacuum-powered bubble extraction (HVBE) method using ethanol was applied for extraction of flavonoids from Phyllostachys pubescens (P. pubescens) leaves. The mechanisms of homogenate-assisted extraction and vacuum-powered bubble generation were discussed in detail. Furthermore, a method for the rapid determination of flavonoids by HPLC was established. HVBE followed by HPLC was successfully applied for the extraction and quantification of four flavonoids in P. pubescens , including orientin, isoorientin, vitexin, and isovitexin. This method provides a fast and effective means for the preparation and determination of plant active components. Moreover, the on-line antioxidant capacity, including scavenging positive ion and negative ion free radical capacity of different fractions from the bamboo flavonoid extract was evaluated. Results showed that the scavenging DPPH ˙ free radical capacity of vitexin and isovitexin was larger than that of isoorientin and orientin. On the contrary, the scavenging ABTS⁺ ˙ free radical capacity of isoorientin and orientin was larger than that of vitexin and isovitexin.

  4. On-line micro-volume introduction system developed for lower density than water extraction solvent and dispersive liquid–liquid microextraction coupled with flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Anthemidis, Aristidis N.; Mitani, Constantina; Balkatzopoulou, Paschalia; Tzanavaras, Paraskevas D.

    2012-01-01

    Highlights: ► A dispersive liquid–liquid micro extraction method for lead and copper determination. ► A micro-volume transportation system for extractant solvent lighter than water. ► Analysis of natural water samples. - Abstract: A simple and fast preconcentration/separation dispersive liquid–liquid micro extraction (DLLME) method for metal determination based on the use of extraction solvent with lower density than water has been developed. For this purpose a novel micro-volume introduction system was developed enabling the on-line injection of the organic solvent into flame atomic absorption spectrometry (FAAS). The effectiveness and efficiency of the proposed system were demonstrated for lead and copper preconcentration in environmental water samples using di-isobutyl ketone (DBIK) as extraction solvent. Under the optimum conditions the enhancement factor for lead and copper was 187 and 310 respectively. For a sample volume of 10 mL, the detection limit (3 s) and the relative standard deviation were 1.2 μg L −1 and 3.3% for lead and 0.12 μg L −1 and 2.9% for copper respectively. The developed method was evaluated by analyzing certified reference material and it was applied successfully to the analysis of environmental water samples.

  5. Liquid chromatography mass spectrometry determination of perfluoroalkyl acids in environmental solid extracts after phospholipid removal and on-line turbulent flow chromatography purification.

    Science.gov (United States)

    Mazzoni, M; Polesello, S; Rusconi, M; Valsecchi, S

    2016-07-01

    An on-line TFC (Turbulent Flow Chromatography) clean up procedures coupled with UHPLC-MS/MS (Ultra High Performance Liquid Chromatography Mass Spectrometry) multi-residue method was developed for the simultaneous determination of 8 perfluroalkyl carboxylic acids (PFCA, from 5 to 12 carbon atoms) and 3 perfluoroalkyl sulfonic acids (PFSA, from 4 to 8 carbon atoms) in environmental solid matrices. Fast sample preparation procedure was based on a sonication-assisted extraction with acetonitrile. Phospholipids in biological samples were fully removed by an off-line SPE purification before injection, using HybridSPE(®) Phospholipid Ultra cartridges. The development of the on-line TFC clean-up procedure regarded the choice of the stationary phase, the optimization of the mobile phase composition, flow rate and injected volume. The validation of the optimized method included the evaluation of matrix effects, accuracy and reproducibility. Signal suppression in the analysis of fortified extracts ranged from 1 to 60%, and this problem was overcome by using isotopic dilution. Since no certified reference materials were available for PFAS in these matrices, accuracy was evaluated by recoveries on spiked clam samples which were 98-133% for PFCAs and 40-60% for PFSAs. MLDs and MLQs ranged from 0.03 to 0.3ngg(-1) wet weight and from 0.1 to 0.9ngg(-1) wet weight respectively. Repeatability (intra-day precision) and reproducibility (inter-day precision) showed RSD from 3 to 13% and from 4 to 27% respectively. Validated on-line TFC/UHPLC-MS/MS method has been applied for the determination of perfluoroalkyl acids in different solid matrices (sediment, fish, bivalves and bird yolk). Copyright © 2016 Elsevier B.V. All rights reserved.

  6. On-line monitoring of extraction process of Flos Lonicerae Japonicae using near infrared spectroscopy combined with synergy interval PLS and genetic algorithm

    Science.gov (United States)

    Yang, Yue; Wang, Lei; Wu, Yongjiang; Liu, Xuesong; Bi, Yuan; Xiao, Wei; Chen, Yong

    2017-07-01

    There is a growing need for the effective on-line process monitoring during the manufacture of traditional Chinese medicine to ensure quality consistency. In this study, the potential of near infrared (NIR) spectroscopy technique to monitor the extraction process of Flos Lonicerae Japonicae was investigated. A new algorithm of synergy interval PLS with genetic algorithm (Si-GA-PLS) was proposed for modeling. Four different PLS models, namely Full-PLS, Si-PLS, GA-PLS, and Si-GA-PLS, were established, and their performances in predicting two quality parameters (viz. total acid and soluble solid contents) were compared. In conclusion, Si-GA-PLS model got the best results due to the combination of superiority of Si-PLS and GA. For Si-GA-PLS, the determination coefficient (Rp2) and root-mean-square error for the prediction set (RMSEP) were 0.9561 and 147.6544 μg/ml for total acid, 0.9062 and 0.1078% for soluble solid contents, correspondingly. The overall results demonstrated that the NIR spectroscopy technique combined with Si-GA-PLS calibration is a reliable and non-destructive alternative method for on-line monitoring of the extraction process of TCM on the production scale.

  7. An automated flow injection system for metal determination by flame atomic absorption spectrometry involving on-line fabric disk sorptive extraction technique.

    Science.gov (United States)

    Anthemidis, A; Kazantzi, V; Samanidou, V; Kabir, A; Furton, K G

    2016-08-15

    A novel flow injection-fabric disk sorptive extraction (FI-FDSE) system was developed for automated determination of trace metals. The platform was based on a minicolumn packed with sol-gel coated fabric media in the form of disks, incorporated into an on-line solid-phase extraction system, coupled with flame atomic absorption spectrometry (FAAS). This configuration provides minor backpressure, resulting in high loading flow rates and shorter analytical cycles. The potentials of this technique were demonstrated for trace lead and cadmium determination in environmental water samples. The applicability of different sol-gel coated FPSE media was investigated. The on-line formed complex of metal with ammonium pyrrolidine dithiocarbamate (APDC) was retained onto the fabric surface and methyl isobutyl ketone (MIBK) was used to elute the analytes prior to atomization. For 90s preconcentration time, enrichment factors of 140 and 38 and detection limits (3σ) of 1.8 and 0.4μgL(-1) were achieved for lead and cadmium determination, respectively, with a sampling frequency of 30h(-1). The accuracy of the proposed method was estimated by analyzing standard reference materials and spiked water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. On-line anti-acetylcholine esterase activity of extracts of oxystelma esculentum, aerva javanica and zanthoxylum armatum

    International Nuclear Information System (INIS)

    Murtaza, S.; Ullah, R. S.; Abbas, A.; Riaz, T.; Ghous, T.; Altaf, Y.; Khan, M.; Ahmed, S.

    2013-01-01

    Alzheimer's disease (AD), a disease of brain, resulting in memory impairment and the loss of thinking. The main reason of Alzheimer's disease is firmly associated with some impairment in cholinergic transmission. This impairment may be improved by diminishing the breakdown of acetylcholine at the synaptic site in the brain by inhibiting acetylcholinesterase (AChE). In this work, extracts of three different plants Oxystelma esculentum (OEM), Aerva javanica (AJM) and Zanthoxylum armatum (ZAA) have been screened for their anti-AchE activity. Results of the study demonstrate that of the studied extracts, ZAA (IC/sub 50/ 55.5 micro g/ml) acquired stronger anti-AChE activity. While OEM with IC/sub 50/ 107.2 micro g/ml showed moderate and ZAE and AJM showed weaker action (IC/sub 50/ 182.5 and 275.2 micro g/ml). Galanthamine was used as a positive control (IC/sub 50/ 1.47 micro g/ml). (author)

  9. A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Jabbar, Dunia; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-10-31

    In the present work, a needle trap utilizing a molecularly imprinted sol-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sol-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5nmolL(-1), respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000nmolL(-1) in both plasma and urine samples. The coefficients of determination values (R(2)) were ≥0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. On-line extraction of the variance caused by burn-up in in-core three-dimensional power distribution

    International Nuclear Information System (INIS)

    Wang Yaqi; Luo Zhengpei; Li Fu; Liu Wenfeng

    2001-01-01

    In most of PWRs, the ex-core ion-chambers are the sole real-time sensors to respond to in-core power and its axial offset. However, the calibration coefficient of the ion-chambers depends on the (3D) power distribution and varies with the burn-up. People expect to know the variance in distribution caused by burn-up directly from the signals of ion-chambers. This expectation is not realized as yet, because an ion-chamber almost only responds to its nearest fuel assemblies. The authors then developed a two-step method for burn-up characteristic extraction: the harmonics synthesis method and harmonics' burn-up grouping. Using the extracted burn-up characteristics, the relationship between the readings of the ex-core ion-chambers and the in-core 3D power distribution is set up. Through the simulation on the heating reactor, the method of burn-up characteristic extraction is verified under engineering conditions. It is possible to on-line extract the variance caused by burn-up in 3D power distribution

  11. On-line solid-phase extraction coupled to hydrophilic interaction chromatography-mass spectrometry for the determination of polar drugs.

    Science.gov (United States)

    Fontanals, Núria; Marcé, Rosa M; Borrull, Francesc

    2011-09-02

    The present study describes the first fully automated method based on on-line solid-phase extraction (SPE) coupled to hydrophilic interaction chromatography-electrospray-mass spectrometry (HILIC-(ESI)MS) to determine a group of polar drugs that includes illicit drugs (such as cocaine, morphine, codeine and metabolites) and pharmaceuticals in environmental water samples. The SPE was performed using a highly retentive polymeric sorbent. The HILIC separation was optimised and the initial high organic content of the chromatographic mobile phase, was also suitable for the proper on-line elution of the analytes retained in the SPE column and for enhancing the ESI ionisation efficiency. This method allows the loading of samples of up to 250ml of ultrapure water or 10ml of environmental water samples spiked at low ngl(-1) levels of the analytes. The method yields near 100% recoveries for all the analytes. The method was also validated with environmental water samples with linear ranges from 5 to 1000ngl(-1) and limits of detection ≤2ngl(-1) for most of the compounds. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A. [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)], E-mail: Ensafi@cc.iut.ac.ir; Ghaderi, Ali R. [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2007-09-05

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5 M HNO{sub 3} and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 {mu}g of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5 M HNO{sub 3} solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ng mL{sup -1} Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ng mL{sup -1} Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments.

  13. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue

    International Nuclear Information System (INIS)

    Ensafi, Ali A.; Ghaderi, Ali R.

    2007-01-01

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5 M HNO 3 and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 μg of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5 M HNO 3 solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ng mL -1 Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ng mL -1 Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments

  14. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue.

    Science.gov (United States)

    Ensafi, Ali A; Ghaderi, Ali R

    2007-09-05

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5M HNO(3) and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 microg of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5M HNO(3) solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ngmL(-1) Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ngmL(-1) Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments.

  15. Supercritical fluid extraction as an on-line clean-up technique for determination of riboflavin vitamins in food samples by capillary electrophoresis with fluorimetric detection.

    Science.gov (United States)

    Zougagh, Mohammed; Ríos, Angel

    2008-08-01

    An automatic method for the separation and determination of riboflavin (RF) vitamins (RF, flavin mononucleotide and flavin adenine dinucleotide) in food samples (chicken liver, tablet and powder milk) is proposed. The method is based on the on-line coupling of a supercritical fluid extractor (SFE) with a continuous flow-CE system with guided optical fiber fluorimetric detection (CF-CE-FD). The whole SFE-CF-CE-FD arrangement allowed the automatic treatment of food samples (clean-up of the sample followed by the extraction of the analytes), and the direct introduction of a small volume of the extracted plug to the CE-FD system for the determination of RF vitamins. Fluorescence detection introduced an appropriated sensitivity and contributed to avoid interferences of nonfluorescent polar compounds coming from the matrix samples in the extracted plug. Electrophoretic responses were linear within the 0.05-1 microg/g range, whereas the detection limits of RF vitamins were in the 0.036-0.042 microg/g range. The proposed arrangement opens up interesting prospects for the direct determination of polar analytes in complex samples with a good throughput and high level of automation.

  16. Characterisation of organic compounds in aerosol particles from a finnish forest by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shimmo, Masahiko; Jaentti, Jaana; Hartonen, Kari; Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland); Aalto, Pasi; Kulmala, Markku [Division of Atmospheric Sciences, Department of Physical Sciences, University of Helsinki, P.O. Box 64, 00014, Helsinki (Finland)

    2004-04-01

    During the European Union project Quantification of Aerosol Nucleation in the European Boundary Layer (QUEST), which began in spring 2003, atmospheric aerosol particles were collected in a Finnish Scots pine forest using a high-volume sampler. The organic compounds in the filter samples were then analysed by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS). The sample was first extracted by SFE. During LC the extracts were fractionated into three fractions according to polarity. The final separation was carried out by GC-MS. A fraction volume as high as 840 {mu}L was transferred to the GC, using the partial concurrent eluent evaporation technique. The same instrumentation, with an in-situ SFE derivatisation method, was used to analyse organic acids. Major compounds such as n-alkanes and PAH were analysed quantitatively. Their concentrations were lower than those usually observed in urban areas or in other forest areas in Europe. The wind direction was one of the most important factors affecting changes in the daily concentrations of these compounds. Scots pine needles were analysed with the same system to obtain reference data for identification of biogenic compounds in aerosol particles. Other organic compounds found in this study included hopanes, steranes, n-alkanals, n-alkan-2-ones, oxy-PAH, and alkyl-PAH; some biogenic products, including oxidation products of monoterpenes, were also identified. (orig.)

  17. Determination of etoricoxib in human plasma using automated on-line solid-phase extraction coupled with LC-APCI/MS/MS

    Directory of Open Access Journals (Sweden)

    Sérgio Luiz Dalmora

    2008-01-01

    Full Text Available A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v/ammonium acetate (pH 4.0; 10 mM, run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99. The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.

  18. Chaotic spectra: How to extract dynamic information

    International Nuclear Information System (INIS)

    Taylor, H.S.; Gomez Llorente, J.M.; Zakrzewski, J.; Kulander, K.C.

    1988-10-01

    Nonlinear dynamics is applied to chaotic unassignable atomic and molecular spectra with the aim of extracting detailed information about regular dynamic motions that exist over short intervals of time. It is shown how this motion can be extracted from high resolution spectra by doing low resolution studies or by Fourier transforming limited regions of the spectrum. These motions mimic those of periodic orbits (PO) and are inserts into the dominant chaotic motion. Considering these inserts and the PO as a dynamically decoupled region of space, resonant scattering theory and stabilization methods enable us to compute ladders of resonant states which interact with the chaotic quasi-continuum computed in principle from basis sets placed off the PO. The interaction of the resonances with the quasicontinuum explains the low resolution spectra seen in such experiments. It also allows one to associate low resolution features with a particular PO. The motion on the PO thereby supplies the molecular movements whose quantization causes the low resolution spectra. Characteristic properties of the periodic orbit based resonances are discussed. The method is illustrated on the photoabsorption spectrum of the hydrogen atom in a strong magnetic field and on the photodissociation spectrum of H 3 + . Other molecular systems which are currently under investigation using this formalism are also mentioned. 53 refs., 10 figs., 2 tabs

  19. On-line solid phase extraction using ion-pair microparticles combined with ICP-OES for the simultaneous preconcentration and determination of uranium and thorium

    Energy Technology Data Exchange (ETDEWEB)

    Yousefi, Seyed Reza; Zolfonoun, Ehsan [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). NFCRS

    2016-07-01

    In this work, after on-line and in-situ solid phase extraction technique was used for the extraction and preconcentration of uranium and thorium from aqueous samples prior to inductively coupled plasma optical emission spectrometry (ICP-OES) determination. In this method, sodium hexafluorophosphate (as an ion-pairing agent) was added to the sample solution containing the cationic surfactant (dodecyltrimethylammonium bromide) and the complexing agent (dibenzoylmethane). A cloudy solution was formed as a result of formation of an ion pair between surfactant and hexafluorophosphate. The solid microparticles were passed through a microcolumn filter and the adsorbed microparticles were subsequently eluted with acid, which was directly introduced into the ICP-OES nebulizer. The main variables affecting the pre-concentration and determination steps of uranium and thorium were studied and optimized. Under the optimum conditions, the enhancement factors of 97 and 95 and the detection limits of 0.52 and 0.21 μg L{sup -1} were obtained for uranium and thorium, respectively.

  20. Automated on-line solid phase extraction coupled to HPLC-APCI-MS detection as a versatile tool for the analysis of phenols in water samples

    International Nuclear Information System (INIS)

    Wissiack, R.

    2001-05-01

    In this work a liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS) technique was developed for the determination of phenols and anilines in waste water samples. All relevant parameters were optimized for liquid chromatographic (LC) separation and mass spectrometric (MS) detection. Mass spectrometric detection was used in either negative ionization (NI) or positive ionization (PI) mode, which was depending on the physicochemical properties of the analyte. For screening analysis, full scan mode (SCAN) was used, while selected ion monitoring (SIM) mode of acquisition was used for maximum sensitivity. The optimal interface parameters and solvent compositions were evaluated, which mainly determined the ionization of analytes thus strongly influencing the sensitivity. The quasi-molecular ions were the most abundant signals both for phenols ([M-H]- in NI) and for anilines ([M+H]+ in PI). In general, fragmentation was hardly observed for one-ring phenols. Only fragmentation due to neutral losses of NO, HCl, NH3, CO2, CHO or CO from the functional groups were obtained via collision induced dissociation (CID) in a single quadrupole mass spectrometer. A further source of structural information was the relative intensity of positive and negative ions for one analyte: Only in the case of para-methyl substituted phenols, detection was also possible in positive ionization mode with reasonable sensitivity. In contrast to the phenols, anilines offered somewhat higher structural information due to increased fragmentation through CID, when detected in the positive ionization mode. The main goal of this work was the development of a method for the determination of US EPA priority phenols in different environmental matrices. As highest sensitivity and selectivity was required for this task, a preconcentrating step was necessary, and consequently solid phase extraction (SPE) was coupled on-line to HPLC-APCI-MS. The optimized method allowed the

  1. Determination of 18 veterinary antibiotics in environmental water using high-performance liquid chromatography-q-orbitrap combined with on-line solid-phase extraction.

    Science.gov (United States)

    Kim, Chansik; Ryu, Hong-Duck; Chung, Eu Gene; Kim, Yongseok

    2018-05-01

    The use of antibiotics and their occurrence in the environment have received significant attention in recent years owing to the generation of antibiotic-resistant bacteria. Antibiotic residues in water near livestock farming areas should be monitored to establish effective strategies for reducing the use of veterinary antibiotics. However, environmental water contamination resulting from veterinary antibiotics has not been studied extensively. In this work, we developed an analytical method for the simultaneous determination of multiple classes of veterinary antibiotic residues in environmental water using on-line solid-phase extraction (SPE)-high performance liquid chromatography (HPLC)-high resolution mass spectrometry (HRMS). Eighteen popular antibiotics (eight classes) were selected as target analytes based on veterinary antibiotics sales in South Korea in 2015. The developed method was validated by calibration-curve linearities, precisions, relative recoveries, and method detection limits (MDLs)/limits of quantification (LOQs) of the selected antibiotics, and applied to the analysis of environmental water samples (groundwater, river water, and wastewater-treatment-plant effluent). All calibration curves exhibited r 2  > 0.995 with MDLs ranging from 0.2 to 11.9 ng/L. Relative recoveries were between 50 and 150% with coefficients of variation below 20% for all analytes (spiked at 500 ng/L) in groundwater and river water samples. Relative standard deviations (RSDs) of standard-spiked samples were lower than 7% for all antibiotics. The on-line SPE system eliminates human-based SPE errors and affords excellent method reproducibility. Amoxicillin, ampicillin, clopidol, fenbendazole, flumequine, lincomycin, sulfadiazine, and trimethoprim were detected in environmental water samples in concentrations ranging from 1.26 to 127.49 ng/L. The developed method is a reliable analytical technique for the potential routine monitoring of veterinary antibiotics

  2. Determination of six microcystins and nodularin in surface and drinking waters by on-line solid phase extraction-ultra high pressure liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix

    2012-11-30

    Microcystins and nodularin are cyclic peptides hepatotoxins produced by cyanobacterial genera (blue-green algae). Toxic cyanobacterial blooms are a worldwide problem, as reported in several countries, like China, Australia, or the United States. Therefore, it is necessary to develop sensitive and reliable analytical methodology to determine this type of toxins in water at parts per billion levels, or even lower. In this work, the potential of solid-phase extraction coupled on-line to ultra-high-pressure liquid chromatography/electrospray tandem mass spectrometry (SPE-UHPLC-MS/MS) has been investigated for the efficient quantification and confirmation of microcystins LR, RR, YR, LY, LW, LF and nodularin in surface and drinking water samples, at sub-ppb levels. The method developed involves the injection of only 1 mL of water sample into the on-line SPE-UHPLC-MS/MS system and allows the rapid determination of the compounds selected (8 min of chromatographic run), avoiding laborious sample treatment. The method was validated in surface and drinking water by means of recovery experiments at 0.25 and 1 μg L(-1). Average recoveries (n=5) ranged from 71 to 116%, with relative standard deviations (RSDs) lower than 15%. For microcystins LR, RR, YR and nodularin, a third level was also assayed (0.1 μg L(-1)) obtaining satisfactory data too. Limits of detection between 0.002 and 0.0405 μg L(-1) were estimated (0.0005 μg L(-1) for nodularin). The developed method was applied to the analysis of water samples collected in the province of Castellón (Spain). The acquisition of three MS/MS transitions for each compound allowed the unequivocal confirmation of positive samples, which was supported by the accomplishment of ion intensity ratios and retention time when compared with reference standards. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Determination of inorganic arsenic in algae using bromine halogenation and on-line nonpolar solid phase extraction followed by hydride generation atomic fluorescence spectrometry.

    Science.gov (United States)

    Zhang, Weihong; Qi, Yuehan; Qin, Deyuan; Liu, Jixin; Mao, Xuefei; Chen, Guoying; Wei, Chao; Qian, Yongzhong

    2017-08-01

    Accurate, stable and fast analysis of toxic inorganic arsenic (iAs) in complicated and arsenosugar-rich algae matrix is always a challenge. Herein, a novel analytical method for iAs in algae was reported, using bromine halogenation and on-line nonpolar solid phase extraction (SPE) followed by hydride generation atomic fluorescence spectrometry (HG-AFS). The separation of iAs from algae was first performed by nonpolar SPE sorbent using Br - for arsenic halogenation. Algae samples were extracted with 1% perchloric acid. Then, 1.5mL extract was reduced by 1% thiourea, and simultaneously reacted (for 30min) with 50μL of 10% KBr for converting iAs to AsBr 3 after adding 3.5mL of 70% HCl to 5mL. A polystyrene (PS) resin cartridge was employed to retain arsenicals, which were hydrolyzed, eluted from the PS resin with H 2 O, and categorized as iAs. The total iAs was quantified by HG-AFS. Under optimum conditions, the spiked recoveries of iAs in real algae samples were in the 82-96% range, and the method achieved a desirable limit of detection of 3μgkg -1 . The inter-day relative standard deviations were 4.5% and 4.1% for spiked 100 and 500μgkg -1 respectively, which proved acceptable for this method. For real algae samples analysis, the highest presence of iAs was found in sargassum fusiforme, followed by kelp, seaweed and laver. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Stability of arsenic peptides in plant extracts: off-line versus on-line parallel elemental and molecular mass spectrometric detection for liquid chromatographic separation.

    Science.gov (United States)

    Bluemlein, Katharina; Raab, Andrea; Feldmann, Jörg

    2009-01-01

    The instability of metal and metalloid complexes during analytical processes has always been an issue of an uncertainty regarding their speciation in plant extracts. Two different speciation protocols were compared regarding the analysis of arsenic phytochelatin (As(III)PC) complexes in fresh plant material. As the final step for separation/detection both methods used RP-HPLC simultaneously coupled to ICP-MS and ES-MS. However, one method was the often used off-line approach using two-dimensional separation, i.e. a pre-cleaning step using size-exclusion chromatography with subsequent fraction collection and freeze-drying prior to the analysis using RP-HPLC-ICP-MS and/or ES-MS. This approach revealed that less than 2% of the total arsenic was bound to peptides such as phytochelatins in the root extract of an arsenate exposed Thunbergia alata, whereas the direct on-line method showed that 83% of arsenic was bound to peptides, mainly as As(III)PC(3) and (GS)As(III)PC(2). Key analytical factors were identified which destabilise the As(III)PCs. The low pH of the mobile phase (0.1% formic acid) using RP-HPLC-ICP-MS/ES-MS stabilises the arsenic peptide complexes in the plant extract as well as the free peptide concentration, as shown by the kinetic disintegration study of the model compound As(III)(GS)(3) at pH 2.2 and 3.8. But only short half-lives of only a few hours were determined for the arsenic glutathione complex. Although As(III)PC(3) showed a ten times higher half-life (23 h) in a plant extract, the pre-cleaning step with subsequent fractionation in a mobile phase of pH 5.6 contributes to the destabilisation of the arsenic peptides in the off-line method. Furthermore, it was found that during a freeze-drying process more than 90% of an As(III)PC(3) complex and smaller free peptides such as PC(2) and PC(3) can be lost. Although the two-dimensional off-line method has been used successfully for other metal complexes, it is concluded here that the fractionation and

  5. Real-time synchronization of batch trajectories for on-line multivariate statistical process control using Dynamic Time Warping

    OpenAIRE

    González Martínez, Jose María; Ferrer Riquelme, Alberto José; Westerhuis, Johan A.

    2011-01-01

    This paper addresses the real-time monitoring of batch processes with multiple different local time trajectories of variables measured during the process run. For Unfold Principal Component Analysis (U-PCA)—or Unfold Partial Least Squares (U-PLS)-based on-line monitoring of batch processes, batch runs need to be synchronized, not only to have the same time length, but also such that key events happen at the same time. An adaptation from Kassidas et al.'s approach [1] will be introduced to ach...

  6. Analysis of particulate polycyclic aromatic hydrocarbons by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Science.gov (United States)

    Shimmo, Masahiko; Adler, Heidi; Hyötyläinen, Tuulia; Hartonen, Kari; Kulmala, Markku; Riekkola, Marja-Liisa

    An on-line supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS) method was developed for the analysis of the particulate polycyclic aromatic hydrocarbons (PAHs). The limits of detection of the system for the quantification standards were in the range of 0.25-0.57 ng, while the limits of determinations for filter samples varied from 0.02 to 0.04 ng m -3 (24 h sampling). The linearity was excellent from 5 to 300 ng ( R2>0.967). The analysis could be carried out in a closed system without tedious manual sample pretreatment and with no risk of errors by contamination or loss of the analytes. The results of the SFE-LC-GC-MS method were comparable with those for Soxhlet and shake-flask extractions with GC-MS. The new method was applied to the analysis of PAHs collected by high-volume filter in the Helsinki area to study the seasonal trend of the concentrations. The individual PAH concentrations varied from 0.015 to more than 1 ng m -3, while total PAH concentrations varied from 0.81 to 5.68 ng m -3. The concentrations were generally higher in winter than in summer. The mass percentage of the total PAHs in total suspended particulates ranged from 2.85×10 -3% in July to 15.0×10 -3% in December. Increased emissions in winter, meteorological conditions, and more serious artefacts during the sampling in summer season may explain the concentration profiles.

  7. On-line SPE-UHPLC method using fused core columns for extraction and separation of nine illegal dyes in chilli-containing spices.

    Science.gov (United States)

    Khalikova, Maria A; Satínský, Dalibor; Smidrkalová, Tereza; Solich, Petr

    2014-12-01

    The presented work describes the development of a simple, fast and effective on-line SPE-UHPLC-UV/vis method using fused core particle columns for extraction, separation and quantitative analysis of the nine illegal dyes, most frequently found in chilli-containing spices. The red dyes Sudan I-IV, Sudan Red 7B, Sudan Red G, Sudan Orange G, Para Red, and Methyl Red were separated and analyzed in less than 9 min without labor-consuming pretreatment procedure. The chromatographic separation was performed on Ascentis Express RP-Amide column with gradient elution using mixture of acetonitrile and water, as a mobile phase at a flow rate of 1.0 mL min(-1) and 55°C of temperature. As SPE sorbent for cleanup and pre-concentration of illegal dyes short guard fused core column Ascentis Express F5 was used. The applicability of proposed method was proven for three different chilli-containing commercial samples. Recoveries for all compounds were between 90% and 108% and relative standard deviation ranged from 1% to 4% for within- and from 2% to 6% for between-day. Limits of detection showed lower values than required by European Union regulations and were in the range of 3.3-10.3 µg L(-1) for standard solutions, 5.6-235.6 µg kg(-1) for chilli-containing spices. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on-line solid-phase extraction technique.

    Science.gov (United States)

    Uchiyama, Kazuhisa; Kondo, Mari; Yokochi, Rika; Takeuchi, Yuri; Yamamoto, Atsushi; Inoue, Yoshinori

    2011-07-01

    A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Determination of biocides and pesticides by on-line solid phase extraction coupled with mass spectrometry and their behaviour in wastewater and surface water

    International Nuclear Information System (INIS)

    Singer, Heinz; Jaus, Sylvia; Hanke, Irene; Lueck, Alfred; Hollender, Juliane; Alder, Alfredo C.

    2010-01-01

    This study focused on the input of hydrophilic biocides into the aquatic environment and on the efficiency of their removal in conventional wastewater treatment by a mass flux analysis. A fully automated method consisting of on-line solid phase extraction coupled to LC-ESI-MS/MS was developed and validated for the simultaneous trace determination of different biocidal compounds (1,2-benzisothiazoline-3-one (BIT), 3-Iodo-2-propynylbutyl-carbamate (IPBC), irgarol 1051 and 2-N-octyl-4-isothiazolinone (octhilinone, OIT), carbendazim, diazinon, diuron, isoproturon, mecoprop, terbutryn and terbutylazine) and pharmaceuticals (diclofenac and sulfamethoxazole) in wastewater and surface water. In the tertiary effluent, the highest average concentrations were determined for mecoprop (1010 ng/L) which was at comparable levels as the pharmaceuticals diclofenac (690 ng/L) and sulfamethoxazole (140 ng/L) but 1-2 orders of magnitude higher than the other biocidal compounds. Average eliminations for all compounds were usually below 50%. During rain events, increased residual amounts of biocidal contaminants are discharged to receiving surface waters. - Incomplete removal of biocides and pesticides during wastewater treatment.

  10. Determination of biocides and pesticides by on-line solid phase extraction coupled with mass spectrometry and their behaviour in wastewater and surface water

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Heinz; Jaus, Sylvia; Hanke, Irene; Lueck, Alfred; Hollender, Juliane [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, CH-8600 Duebendorf (Switzerland); Alder, Alfredo C., E-mail: alfredo.alder@eawag.c [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, CH-8600 Duebendorf (Switzerland)

    2010-10-15

    This study focused on the input of hydrophilic biocides into the aquatic environment and on the efficiency of their removal in conventional wastewater treatment by a mass flux analysis. A fully automated method consisting of on-line solid phase extraction coupled to LC-ESI-MS/MS was developed and validated for the simultaneous trace determination of different biocidal compounds (1,2-benzisothiazoline-3-one (BIT), 3-Iodo-2-propynylbutyl-carbamate (IPBC), irgarol 1051 and 2-N-octyl-4-isothiazolinone (octhilinone, OIT), carbendazim, diazinon, diuron, isoproturon, mecoprop, terbutryn and terbutylazine) and pharmaceuticals (diclofenac and sulfamethoxazole) in wastewater and surface water. In the tertiary effluent, the highest average concentrations were determined for mecoprop (1010 ng/L) which was at comparable levels as the pharmaceuticals diclofenac (690 ng/L) and sulfamethoxazole (140 ng/L) but 1-2 orders of magnitude higher than the other biocidal compounds. Average eliminations for all compounds were usually below 50%. During rain events, increased residual amounts of biocidal contaminants are discharged to receiving surface waters. - Incomplete removal of biocides and pesticides during wastewater treatment.

  11. Sequential injection-bead injection-lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Wang Jianhua; Hansen, Elo Harald; Miro, Manuel

    2003-01-01

    This communication presents an overview of the state-of-the-art of the exploitation of sequential injection (SI)-bead injection (BI)-lab-on-valve (LOV) schemes for automatic on-line sample pre-treatments interfaced with ETAAS and ICPMS detection as conducted in the authors' group. The discussions are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material, that is, the hydrophilic SP Sephadex C-25 cation exchange and iminodiacetate based Muromac A-1 chelating resins, and the hydrophobic poly(tetrafluoroethylene) (PTFE) and poly(styrene-divinylbenzene) copolymer alkylated with octadecyl groups (C 18 -PS/DVB). Using ETAAS as detection device, the easy-to-handle hydrophilic renewable reactors hold the features of improved R.S.D.s and LODs as compared to those operated in the conventional, permanent mode, in addition to the elimination of flow resistance. The hydrophobic columns fall into two categories, that is, the renewable one packed with C 18 -PS/DVB beads entails analogous R.S.D.s and LODs with respect to the conventional approach, while those with PTFE beads result in slightly inferior R.S.D.s and LODs by similar comparison, yet offering a wider dynamic range than when using an external permanent column. Moreover, the hydrophilic materials result in much higher enrichment of the analyte than the hydrophobic ones, although PTFE is the packing material that exhibits the best retention efficiency

  12. On-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry using Fab´antibody fragments for the analysis of serum transthyretin.

    Science.gov (United States)

    Pont, Laura; Benavente, Fernando; Barbosa, José; Sanz-Nebot, Victoria

    2017-08-01

    This paper describes an on-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry (IA-SPE-CE-MS) method using an immunoaffinity sorbent with Fab' antibody fragments (Fab'-IA) for the analysis of serum transthyretin (TTR), a homotetrameric protein (M r ~56,000) involved in different types of amyloidosis. The IA sorbent was prepared by covalent attachment of Fab' fragments obtained from a polyclonal IgG antibody against TTR to succinimidyl silica particles. The Fab'-IA-SPE-CE-MS methodology was first established analyzing TTR standard solutions. Under optimized conditions, repeatability and reproducibility were acceptable, the method was linear between 1 and 25µgmL -1 , limits of detection (LODs) were around 0.5µgmL -1 (50-fold lower than by CE-MS, ~25µgmL -1 ) and different TTR conformations were observed (folded and unfolded). The applicability of the developed method to screen for familial amyloidotic polyneuropathy type I (FAP-I), which is the most common hereditary systemic amyloidosis, was evaluated analyzing serum samples from healthy controls and FAP-I patients. For the analysis of sera, the most abundant proteins were precipitated with 5% (v/v) of phenol before Fab'-IA-SPE-CE-MS. The current method enhanced our previous results for the analysis of TTR using intact antibodies immobilized on magnetic beads. It allowed a slight improvement on LODs (2-fold), the detection of proteoforms found at lower concentrations and the preparation of microcartridges with extended durability. Copyright © 2017. Published by Elsevier B.V.

  13. Profiling of tryptophan-related plasma indoles in patients with carcinoid tumors by automated, on-line, solid-phase extraction and HPLC with fluorescence detection.

    Science.gov (United States)

    Kema, I P; Meijer, W G; Meiborg, G; Ooms, B; Willemse, P H; de Vries, E G

    2001-10-01

    Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P manual, single-component analyses.

  14. An automated method for the analysis of phenolic acids in plasma based on ion-pairing micro-extraction coupled on-line to gas chromatography/mass spectrometry with in-liner derivatisation

    NARCIS (Netherlands)

    Peters, S.; Kaal, E.; Horsting, I.; Janssen, H.-G.

    2012-01-01

    A new method is presented for the analysis of phenolic acids in plasma based on ion-pairing ‘Micro-extraction in packed sorbent’ (MEPS) coupled on-line to in-liner derivatisation-gas chromatography-mass spectrometry (GC-MS). The ion-pairing reagent served a dual purpose. It was used both to improve

  15. Sequential injection/bead injection lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Miró, Manuel

    2003-01-01

    are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material...

  16. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    NARCIS (Netherlands)

    Slobodník, J.; Oztekizan, O.; Lingeman, H.; Brinkman, U.A.T.

    1996-01-01

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2

  17. Rapid and simple one-step membrane extraction for the determination of 8-hydroxy-2'-deoxyguanosine in human plasma by a combination of on-line solid phase extraction and LC-MS/MS.

    Science.gov (United States)

    Wang, Chien-Jen; Yang, Ning-Hsiang; Chang, Chia-Chi; Liou, Saou-Hsing; Lee, Hui-Ling

    2011-11-15

    A quantitative analytical method using automated on-line solid phase extraction (SPE) and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of 8-OHdG (8-hydroxy-2'-deoxyguanosine) in human plasma was developed and validated. A one-step membrane extraction method for the plasma sample preparation and a C18 SPE column with simple extraction and purification were used for the on-line extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. (15)N(5)-8-OHdG ((15)N(5)-8-hydroxy-2'-deoxyguanosine) was used as an internal standard for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve as one strategy to reduce the matrix effect and simultaneously improve detection sensitivity. Identification and quantification were based on the following transitions: m/z 284→168 for 8-OHdG and m/z 289→173 for (15)N(5)-8-OHdG. Satisfactory recovery was obtained, and the recovery ranged from 95.1 to 106.1% at trace levels in human plasma and urine, with a CV lower than 5.4%. Values for intraday and interday precision were between 2.3 and 6.8% for plasma and between 2.7 and 4.5% for urine, respectively. Values for the method accuracy of intraday and interday assays ranged from 93.0 and 100.5% for plasma and 110.2 and 119.4% for urine, respectively. The limits of detection (LOD) and LOQ were 0.008 ng/mL and 0.02 ng/mL, respectively.The applicability of this newly developed method was demonstrated by analysis of human plasma samples for an evaluation of the future risk of oxidative stress status in human exposure to nanoparticles and other diseases. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  18. Beam dynamics prior to extraction in Kolkata superconducting cyclotron

    International Nuclear Information System (INIS)

    Paul, S.; Debnath, J.; Dey, M.K.; Mallik, C.; Bhandari, R.K.

    2011-01-01

    The Kolkata Superconducting Cyclotron has already accelerated test beams up to its extraction radius. Efforts are underway to extract the internal beam with the aid of the various extraction elements. A detailed study of the accelerated beams dynamics has been carried out to ensure that before extraction, optimum turn separation is achieved and the beam does not cross the harmful third order coupling resonance, while keeping distortions to a manageable levels. This paper discusses those results and the studies conducted. (author)

  19. On-line solid phase extraction-liquid chromatography-tandem mass spectrometry for insect repellent residue analysis in surface waters using atmospheric pressure photoionization.

    Science.gov (United States)

    Molins-Delgado, Daniel; García-Sillero, Daniel; Díaz-Cruz, M Silvia; Barceló, Damià

    2018-04-06

    Insect repellents (IRs) are a group of organic chemicals whose function is to prevent the ability of insects of landing in a surface. These compounds have been found in the environment and may pose a risk to non-target organisms. In this study, an on-line solid phase extraction - high performance liquid chromatography-tandem mass spectrometry multiresidue method was developed using an atmospheric photoionization source (SPE-HPLC-(APPI)-MS/MS). The use of the APPI as an alternative ionization technique to electrospray (ESI) and atmospheric pressure chemical ionization (APCI) allowed expanding the range of analytical techniques suitable for the analysis of IRs, so far relied in gas chromatography. High sensitivity and precision was reached with method limits of quantification between 0.2 and 4.6 ng l -1 and interday and intraday precision equal or below 15%. The validated method was applied to the study of surface water samples from three European river basins with different flow regime (Adige River in Italy, Sava River in the Balkans, and Evrotas River in Greece). The results showed that two IRs (DEET and Bayrepel) were ubiquitous in the Sava and Evrotas basins, reaching concentrations as high as 105 μg l -1 of Bayrepel in the Sava River, and 5 μg l -1 of DEET in the Evrotas River. Densely populated areas and effluent waste waters are pointed out as the responsible for this pollution. In the alpine river Adige, only three samples showed low levels of IRs (6.01-37.8 ng l -1 ). The concentrations measured were used to perform an environmental risk assessment based on the hazard quotients (HQs) estimation approach by using the chronic and acute eco-toxicity data available. The results revealed that despite the high frequency and eventually high concentrations of these IRs determined in the three basins, only few sites were at risk, with 1 < HQs < 3.3. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  20. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, Mirna, E-mail: msigrist@fiq.unl.edu.ar [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Albertengo, Antonela; Beldomenico, Horacio [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Tudino, Mabel [Laboratorio de Analisis de Trazas, Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE, Facultad de Ciencias Exactas y Naturales, Pabellon II, Ciudad Universitaria (1428), Buenos Aires (Argentina)

    2011-04-15

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH{sub 3} generation using 3.5 mol L{sup -1} HCl as carrier solution and 0.35% (m/v) NaBH{sub 4} in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, HPO{sub 4}{sup 2-}, HCO{sub 3}{sup -} on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C{sub 6}H{sub 8}O{sub 6} solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 {mu}g L{sup -1} and 0.6 {mu}g L{sup -1} for As(III) and inorganic total As, respectively, were obtained for a 500 {mu}L sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h{sup -1}. The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species

  1. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Sigrist, Mirna; Albertengo, Antonela; Beldomenico, Horacio; Tudino, Mabel

    2011-01-01

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH 3 generation using 3.5 mol L -1 HCl as carrier solution and 0.35% (m/v) NaBH 4 in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl - , SO 4 2- , NO 3 - , HPO 4 2- , HCO 3 - on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C 6 H 8 O 6 solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 μg L -1 and 0.6 μg L -1 for As(III) and inorganic total As, respectively, were obtained for a 500 μL sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h -1 . The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species separation was performed through the employ of a serial connection of membrane filters and

  2. Per- and polyfluoroalkyl substances and fluorinated alternatives in urine and serum by on-line solid phase extraction-liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kato, Kayoko; Kalathil, Akil A; Patel, Ayesha M; Ye, Xiaoyun; Calafat, Antonia M

    2018-06-14

    Per- and polyfluoroalkyl substances (PFAS), man-made chemicals with variable length carbon chains containing the perfluoroalkyl moiety (C n F 2n+1 -), are used in many commercial applications. Since 1999-2000, several long-chain PFAS, including perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA), have been detected at trace levels in the blood of most participants of the National Health and Nutrition Examination Survey (NHANES)-representative samples of the U.S. general population-while short-chain PFAS have not. Lower detection frequencies and concentration ranges may reflect lower exposure to short-chain PFAS than to PFOS or PFOA or that, in humans, short-chain PFAS efficiently eliminate in urine. We developed on-line solid phase extraction-HPLC-isotope dilution-MS/MS methods for the quantification in 50 μL of urine or serum of 15 C 3 -C 11 PFAS (C 3 only in urine), and three fluorinated alternatives used as PFOA or PFOS replacements: GenX (ammonium salt of 2,3,3,3,-tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy)-propanoate, also known as HFPO-DA), ADONA (ammonium salt of 4,8-dioxa-3H-perfluorononanoate), and 9Cl-PF3ONS (9-chlorohexadecafluoro-3-oxanonane-1-sulfonate), main component of F53-B. Limit of detection for all analytes was 0.1 ng/mL. To validate the method, we analyzed 50 commercial urine/serum paired samples collected in 2016 from U.S. volunteers with no known exposure to the chemicals. In serum, detection frequency and concentration patterns agreed well with those from NHANES. By contrast, except for perfluorobutanoate, we did not detect long-chain or short-chain PFAS in urine. Also, we did not detect fluorinated alternatives in either urine or serum. Together, these results suggest limited exposure to both short-chain PFAS and select fluorinated alternatives in this convenience population. Copyright © 2018. Published by Elsevier Ltd.

  3. Dynamic model of a natural water circulation boiler suitable for on-line monitoring of fossil/alternative fuel plants

    International Nuclear Information System (INIS)

    Sedić, Almir; Katulić, Stjepko; Pavković, Danijel

    2014-01-01

    Highlights: • Derivation of dynamic model of a natural water circulation boiler is presented. • Model is derived by employing basic laws of conservation of mass, energy and momentum. • Thus obtained boiler model does not include empirical relationships. • Model is validated against experimental data related to an external disturbance event. • The final model is used for simulation analysis/assessment of key boiler quantities. - Abstract: The environmental protection policies and legal obligations motivate process industries to implement new low-emission and high-efficiency technologies. For the purpose of production process optimization and related control system design it is worthwhile to first build an appropriate process model. Apart from favorable execution speed, accuracy, and reliability features, the model also needs to be straightforward and only include the physical and design characteristics of the overall plant and its individual components, instead of relying on empirical relationships. To this end, this paper presents a nonlinear dynamic model of the single-drum natural-circulation steam boiler evaporator circuit, based exclusively on the fundamental physical laws of conservation of mass, energy and momentum, wherein the reliance upon empirical relationships has been entirely avoided. The presented boiler system modeling approach is based on the analysis of the physical phenomena within the boiler drum, as well as within downcomer and furnace tubes, and it also takes into account the boiler system design-specific features such as cyclone steam separators, thus facilitating the derivation of a fully-physical process model. Due to the straightforwardness of the derived process model, it should also be useful for the analysis of similar steam boiler facilities, requiring only adjustments of key operational and design parameters such as operating pressure, temperature, steam capacity and characteristics of ancillary equipment such as pumps. To

  4. An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples.

    Science.gov (United States)

    Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor

    2018-02-01

    Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.

  5. LC-HR-MS/MS standard urine screening approach: Pros and cons of automated on-line extraction by turbulent flow chromatography versus dilute-and-shoot and comparison with established urine precipitation.

    Science.gov (United States)

    Helfer, Andreas G; Michely, Julian A; Weber, Armin A; Meyer, Markus R; Maurer, Hans H

    2017-02-01

    Comprehensive urine screening for drugs and metabolites by LC-HR-MS/MS using Orbitrap technology has been described with precipitation as simple workup. In order to fasten, automate, and/or simplify the workup, on-line extraction by turbulent flow chromatography and a dilute-and-shoot approach were developed and compared. After chromatographic separation within 10min, the Q-Exactive mass spectrometer was run in full scan mode with positive/negative switching and subsequent data dependent acquisition mode. The workup approaches were validated concerning selectivity, recovery, matrix effects, process efficiency, and limits of identification and detection for typical drug representatives and metabolites. The total workup time for on-line extraction was 6min, for the dilution approach 3min. For comparison, the established urine precipitation and evaporation lasted 10min. The validation results were acceptable. The limits for on-line extraction were comparable with those described for precipitation, but lower than for dilution. Thanks to the high sensitivity of the LC-HR-MS/MS system, all three workup approaches were sufficient for comprehensive urine screening and allowed fast, reliable, and reproducible detection of cardiovascular drugs, drugs of abuse, and other CNS acting drugs after common doses. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Development of a simple extraction cell with bi-directional continuous flow coupled on-line to ICP-MS for assessment of elemental associations in solid samples

    DEFF Research Database (Denmark)

    Buanuam, Janya; Tiptanasup, Kasipa; Shiowatana, Juwadee

    2006-01-01

    A continuous-flow system comprising a novel, custom-built extraction module and hyphenated with inductively coupled plasma-mass spectrometric (ICP-MS) detection is proposed for assessing metal mobilities and geochemical associations in soil compartments as based on using the three step BCR (now...... the Measurements and Testing Programme of the European Commission) sequential extraction scheme. Employing a peristaltic pump as liquid driver, alternate directional flows of the extractants are used to overcome compression of the solid particles within the extraction unit to ensure a steady partitioning flow rate...... and thus to maintain constant operationally defined extraction conditions. The proposed flow set-up is proven to allow for trouble-free handling of soil samples up to 1 g and flow rates ≤ 10 mL min–1. The miniaturized extraction system was coupled to ICP-MS through a flow injection interface in order...

  7. Hydrolysis-extraction of apple proto pectins in dynamic mode

    International Nuclear Information System (INIS)

    Bobodzhonova, G.N.; Gorshkova, R.M.; Makhkamov, Kh.K.

    2013-01-01

    The article describes a hydrolysis process of apple husks by using dynamics regime of hydrolysis. It's shown that application of dynamics method positively influences on the pectin yields and its main parameters. It was defined that by dynamics regime of hydrolysis-extraction of apple husks it is possible to obtain qualitative products with high yield at a mild ph value of medium of hydrolysing agent.

  8. Extraction of dynamical equations from chaotic data

    International Nuclear Information System (INIS)

    Rowlands, G.; Sprott, J.C.

    1991-02-01

    A method is described for extracting from a chaotic time series a system of equations whose solution reproduces the general features of the original data even when these are contaminated with noise. The equations facilitate calculation of fractal dimension, Lyapunov exponents and short-term predictions. The method is applied to data derived from numerical solutions of the Logistic equation, the Henon equations, the Lorenz equations and the Roessler equations. 10 refs., 5 figs

  9. Feature Extraction for Structural Dynamics Model Validation

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, Charles [Los Alamos National Laboratory; Nishio, Mayuko [Yokohama University; Hemez, Francois [Los Alamos National Laboratory; Stull, Chris [Los Alamos National Laboratory; Park, Gyuhae [Chonnam Univesity; Cornwell, Phil [Rose-Hulman Institute of Technology; Figueiredo, Eloi [Universidade Lusófona; Luscher, D. J. [Los Alamos National Laboratory; Worden, Keith [University of Sheffield

    2016-01-13

    As structural dynamics becomes increasingly non-modal, stochastic and nonlinear, finite element model-updating technology must adopt the broader notions of model validation and uncertainty quantification. For example, particular re-sampling procedures must be implemented to propagate uncertainty through a forward calculation, and non-modal features must be defined to analyze nonlinear data sets. The latter topic is the focus of this report, but first, some more general comments regarding the concept of model validation will be discussed.

  10. Effects of push/pull perfusion and ultrasonication on the extraction efficiencies of phthalate esters in sports drink samples using on-line hollow-fiber liquid-phase microextraction.

    Science.gov (United States)

    Chao, Yu-Ying; Lee, Chien-Hung; Chien, Tzu-Yang; Shih, Yu-Hsuan; Lu, Yin-An; Kuo, Ting-Hsuan; Huang, Yeou-Lih

    2013-08-28

    In previous studies, we developed a process, on-line ultrasound-assisted push/pull perfusion hollow-fiber liquid-phase microextraction (UA-PPP-HF-LPME), combining the techniques of push/pull perfusion (PPP) and ultrasonication with hollow-fiber liquid-phase microextraction (HF-LPME), to achieve rapid extraction of acidic phenols from water samples. In this present study, we further evaluated three more-advanced and novel effects of PPP and ultrasonication on the extraction efficiencies of neutral high-molecular-weight phthalate esters (HPAEs) in sports drinks. First, we found that inner-fiber fluid leakage occurs only in push-only perfusion-based and pull-only perfusion-based HF-LPME, but not in the PPP mode. Second, we identified a significant negative interaction between ultrasonication and temperature. Third, we found that the extraction time of the newly proposed system could be shortened by more than 93%. From an investigation of the factors affecting UA-PPP-HF-LPME, we established optimal extraction conditions and achieved acceptable on-line enrichment factors of 92-146 for HPAEs with a sampling time of just 2 min.

  11. Ultra-trace levels analysis of microcystins and nodularin in surface water by on-line solid-phase extraction with high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Balest, Lydia; Murgolo, Sapia; Sciancalepore, Lucia; Montemurro, Patrizia; Abis, Pier Paolo; Pastore, Carlo; Mascolo, Giuseppe

    2016-06-01

    An on-line solid phase extraction coupled with high-performance liquid chromatography in tandem with mass spectrometry (on-line SPE/HPLC/MS-MS) method for the determination of five microcystins and nodularin in surface waters at submicrogram per liter concentrations has been optimized. Maximum recoveries were achieved by carefully optimizing the extraction sample volume, loading solvent, wash solvent, and pH of the sample. The developed method was also validated according to both UNI EN ISO IEC 17025 and UNICHIM guidelines. Specifically, ten analytical runs were performed at three different concentration levels using a reference mix solution containing the six analytes. The method was applied for monitoring the concentrations of microcystins and nodularin in real surface water during a sampling campaign of 9 months in which the ELISA method was used as standard official method. The results of the two methods were compared showing good agreement when the highest concentration values of MCs were found. Graphical abstract An on-line SPE/HPLC/MS-MS method for the determination of five microcystins and nodularin in surface waters at sub μg L(-1) was optimized and compared with ELISA assay method for real samples.

  12. Dynamic studies of liver and thyroid function with the aid of a gamma camera and an on-line digital computer

    International Nuclear Information System (INIS)

    Raikar, U.R.; Ganatra, R.D.; Samuel, A.M.; Ramanathan, P.; Atmaram, S.H.

    1975-01-01

    Initial experience of dynamic studies with the use of a 16 K digital computer coupled to a scintillation camera is described. 1. A system for scoring bolus was developed taking into account peaking time, the ratio of counts at the peak and at 8 s after the peak and full width at half maximum. Various parameters affecting the boli are discussed. 2. A method is established for finding the slope of net early trapping of sup(99m)TcO 4 in the thyroid after subtraction of extrathyroidal vascular background. This value was found diagnostically useful in establishing the state of thyroid function in 26 patients. 3. Portal extraction half-times of various colloidal radiopharmaceuticals were studied in the first two-minute dynamic study of the liver. This determination provided a method of bioassay for the consistency of the production of colloid for liver scintigraphy. Differences were noted in the trapping time between the right and left lobes of the liver. 4. On the basis of portal extraction half-times, sup(99m)Tc phytate appeared to become colloidal instantaneously after injection into the circulation and its behavior in dynamic studies was more or less identical with that of the sup(99m)Tc-S-colloid. 5. Normal liver has a dual blood supply, while a malignancy in the liver derives blood from only the hepatic artery. Benign lesions such as abscesses and cysts are relatively avascular. This difference in the blood supply of benign and malignant space-occupying lesions in the liver was exploited in an early dynamic study of blood flow to offer a clue to the pathology of cold areas in 170 patients. (author)

  13. On-line solid-phase extraction coupled to liquid chromatography tandem mass spectrometry for the analysis of cyanotoxins in algal blooms.

    Science.gov (United States)

    Fayad, Paul B; Roy-Lachapelle, Audrey; Duy, Sung Vo; Prévost, Michèle; Sauvé, Sébastien

    2015-12-15

    An analytical method based on on-line SPE-LC-HESI-MS/MS has been developed for the detection and quantification of eight selected cyanotoxins in algal bloom waters that include mycrocystins, anatoxin-a and cylindrospermopsin. The injection volume was 2 mL according to the expected concentration of cyanotoxins in matrix. The method provides an analysis time of 7 min per sample, acceptable recovery values (91-101%), good precision (RSD cyanotoxins. All of the targeted cyanotoxins were detected with the exception of cylindrospermopsin. In addition, it was found that total microcystin concentrations in several surface water samples exceeded the proposed guidelines established by the province of Québec in Canada of 1.5 μg L(-1) as well as the World Health Organization of 1 μg L(-1) for both free and cell-bound microcystin-LR equivalent. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. On-line solid phase extraction-gas chromatography-cryotrapping-infrared spectrometry for the trace-level determination of microcontaminants in aqueous samples

    NARCIS (Netherlands)

    Hankemeier, T; Hooijschuur, E.; Vreuls, R.J.J.; Brinkman, U.A.Th.; Visser, T.

    1998-01-01

    A large-volume on-column GC-cryotrapping-IR system was developed for injections of up to 100 μl of organic extracts. Considerable reduction of the solvent-and-water background and enhanced analyte detectability was achieved by using an open-split interface between the GC column and the IR detector

  15. Rapid and automated on-line solid phase extraction HPLC-MS/MS with peak focusing for the determination of ochratoxin A in wine samples.

    Science.gov (United States)

    Campone, Luca; Piccinelli, Anna Lisa; Celano, Rita; Pagano, Imma; Russo, Mariateresa; Rastrelli, Luca

    2018-04-01

    This study reports a fast and automated analytical procedure based on an on-line SPE-HPLC-MS/MS method for the automatic pre-concentration, clean up and sensitive determination of OTA in wine. The amount of OTA contained in 100μL of sample (pH≅5.5) was retained and concentrated on an Oasis MAX SPE cartridge. After a washing step to remove matrix interferents, the analyte was eluted in back-flush mode and the eluent from the SPE column was diluted through a mixing Tee, using an aqueous solution before the chromatographic separation achieved on a monolithic column. The developed method has been validated according to EU regulation N. 519/2014 and applied for the analysis of 41 red and 17 white wines. The developed method features minimal sample handling, low solvent consumption, high sample throughput, low analysis cost and provides an accurate and highly selective results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. On-line nuclear orientation

    International Nuclear Information System (INIS)

    Krane, K.S.

    1990-01-01

    This grant has as its overall goal the pursuit of on-line nuclear orientation experiments for the purpose of eliciting details of nuclear structure from the decays of neutron-deficient nuclei, such as those produced by the Holifield Heavy-Ion Research Facility at Oak Ridge and extracted by the UNISOR Isotope Separator. This paper discusses: refrigerator development; the decay of 184 Au; the decay of 191 Hg to 191 Au; the decay of 189 Pt to 189 Ir; the decays of 109,111 Pd; the decay of 172 Er; and solid angle corrections

  17. A fast and sensitive method for the simultaneous analysis of a wide range of per- and polyfluoroalkyl substances in indoor dust using on-line solid phase extraction-ultrahigh performance liquid chromatography-time-of-flight-mass spectrometry.

    Science.gov (United States)

    Padilla-Sánchez, Juan Antonio; Haug, Line Småstuen

    2016-05-06

    A fast and sensitive method for simultaneous determination of 18 traditional and 6 alternative per- and polyfluoroalkyl substances (PFASs) using solid-liquid extraction (SLE), off-line clean-up using activated carbon and on-line solid phase extraction-ultrahigh performance liquid chromatography-time-of-flight-mass spectrometry (on-line SPE-UHPLC-TOF-MS) was developed. The extraction efficiency was studied and recoveries in range the 58-114% were obtained. Extraction and injection volumes were also optimized to 2mL and 400μL, respectively. The method was validated by spiking dust from a vacuum cleaner bag that had been found to contain low levels of the PFASs in focus. Low method detection limits (MDLs) and method quantification limits (MQLs) in the range 0.008-0.846ngg(-1) and 0.027-2.820ngg(-1) were obtained, respectively. For most of the PFASs, the accuracies were between 70 and 125% in the range from 2 to100ngg(-1) dust. Intra-day and inter-day precisions were in general well below 30%. Analysis of a Standard Reference Material (SRM 2585) showed high accordance with results obtained by other laboratories. Finally, the method was applied to seven indoor dust samples, and PFAS concentrations in the range 0.02-132ngg(-1) were found. The highest median concentrations were observed for some of the alternative PFASs, such as 6:2-diPAP (25ngg(-1)), 8:2-diPAP (49ngg(-1)), and PFOPA (23ngg(-1)), illustrating the importance of inclusion of new PFASs in the analytical methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Graphene oxide-based composite monolith as new sorbent for the on-line solid phase extraction and high performance liquid chromatography determination of ß-sitosterol in food samples.

    Science.gov (United States)

    Cui, Beijiao; Guo, Bin; Wang, Huimin; Zhang, Doudou; Liu, Haiyan; Bai, Ligai; Yan, Hongyuan; Han, Dandan

    2018-08-15

    A composite monolithic column was prepared by redox initiation method for the on-line purification and enrichment of β-sitosterol, in which graphene oxide (GO) was embedded. The obtained monolithic column was characterized by scanning electron microscopy (SEM) and nitrogen adsorption-desorption isotherm measurement, which indicated that the monolith possessed characteristics of porous structure and high permeability. Under the optimum conditions for extraction and determination, the calibration equation was y = 47.92 × -0.1391; the linear range was 0.008-1.0 mg mL -1 ; the linear regression coefficient was 0.998; the limit of detection (LOD) is 2.4 μg mL -1 ; the limit of quantitation (LOQ) was 8 μg mL -1 ; precisions for intra-day and inter-day assays presented as relative standard deviations were less than 4.3% and 6.8%, respectively. Under the selective conditions, the enrichment factor of the method was 119. The recovery was in the range of 80.40-98.00%. Moreover, the adsorption amount of the monolith was compared with silica gel-C18 adsorbent and the monolith without graphene oxide being embedded. The polymerization monolithic column showed high selectivity and good permeability, and it was successfully used as on-line solid-phase extraction (SPE) column for determination of β-sitosterol in edible oil. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Simultaneous determination of caffeine, theophylline and theobromine in human plasma by on-line solid-phase extraction coupled to reversed-phase chromatography.

    Science.gov (United States)

    Emara, Samy

    2004-10-01

    A reversed-phase liquid chromatographic column switching system was described for the determination of caffeine (CF), theophylline (TH) and theobromine (TB) in human plasma with a direct injection procedure. A short protein-coated mu Bondapak CN silica pre-column (20 x 3 mm, i.d.) was used for enrichment of the drugs and clean up from weakly retained plasma components using phosphate buffer saline pH 7.4. After washing step, the retained drugs were flushed into a reversed-phase column (5 microm TSK gel ODS-80 TM, 150 x 4.6 mm i.d.) with a mobile phase of methanol-0.01 M phosphate buffer, pH 3.5 (30:70, v/v) for the final separation. The eluent was monitored with a UV detector at 275 nm. The resulting chromatograms showed no interference from endogenous plasma components. A linear relationship between the concentration of drug and peak height was confirmed in the range of 0.5-20 microg/mL for all drugs. High extraction recoveries from plasma ranging from 96.12 to 100.32% were achieved. Validation of the method was examined performing intra- and inter-day accuracy and precision and was found to be satisfactory. The coefficients of variation of the three drugs were less than 3% for intra-day and less than 4% for inter-day run assays.

  20. Application of cotton as a solid phase extraction sorbent for on-line preconcentration of copper in water samples prior to inductively coupled plasma optical emission spectrometry determination.

    Science.gov (United States)

    Faraji, Mohammad; Yamini, Yadollah; Shariati, Shahab

    2009-07-30

    Copper, as a heavy metal, is toxic for many biological systems. Thus, the determination of trace amounts of copper in environmental samples is of great importance. In the present work, a new method was developed for the determination of trace amounts of copper in water samples. The method is based on the formation of ternary Cu(II)-CAS-CTAB ion-pair and adsorption of it into a mini-column packed with cotton prior applying inductively coupled plasma optical emission spectrometry (ICP-OES). The experimental parameters that affected the extraction efficiency of the method such as pH, flow rate and volume of the sample solution, concentration of chromazurol S (CAS) and cethyltrimethylammonium bromide (CTAB) as well as type and concentration of eluent were investigated and optimized. The ion-pair (Cu(II)-CAS-CTAB) was quantitatively retained on the cotton under the optimum conditions, then eluted completely using a solution of 25% (v/v) 1-propanol in 0.5 mol L(-1) HNO(3) and directly introduced into the nebulizer of the ICP-OES. The detection limit (DL) of the method for copper was 40 ng L(-1) (V(sample)=100mL) and the relative standard deviation (R.S.D.) for the determination of copper at 10 microg L(-1) level was found to be 1.3%. The method was successfully applied to determine the trace amounts of copper in tap water, deep well water, seawater and two different mineral waters, and suitable recoveries were obtained (92-106%).

  1. The study of the dynamic behaviour and safety of nuclear power plants by means of on-line, real time noise signal analysis

    International Nuclear Information System (INIS)

    Kemeny, L.G.

    1973-01-01

    This paper describes an on-line data acquisition system designed to carry out the above funtions. Preliminary results obtained during the monitoring of the HIFAR reactor of the Australian Atomic Energy Commission are reported and discussed. The relationships between experimental measurements and basic stochastic models are explored. (author)

  2. Facile green synthesis of graphene-Au nanorod nanoassembly for on-line extraction and sensitive stripping analysis of methyl parathion

    International Nuclear Information System (INIS)

    Zhu, Wenxin; Liu, Wei; Li, Tianbao; Yue, Xiaoyue; Liu, Tao; Zhang, Wentao; Yu, Shaoxuan; Zhang, Daohong; Wang, Jianlong

    2014-01-01

    Graphical abstract: Schematic illustration for the facile green fabrication of GN-AuNRs/GCE and its application for the extraction and electroanalysis of MP. - Highlights: • This paper described a facile green electrochemical approach to synthesize graphene-AuNRs nanocomposite. • The as-synthesized sensor shows low LOD and wide linear concentration range towards MP. • The sensor can be well used for the determination of MP in water and kiwi fruits samples. • This paper further enlarges the scope of facile green synthetic methods of GN-based hybrids. - Abstract: This paper described a facile green electrochemical approach to synthesize graphene-AuNRs nanocomposite (GN-AuNRs) onto glassy carbon electrode (GCE) for electrocatalytic analysis of methyl parathion (MP). This electrochemical synthesis of GN-AuNRs hybrid is environmentally friendly for not involving the chemical reduction of graphene oxide (GO) and facile for just on the basis of electrostatic interaction between GO and AuNRs, as well as electrochemical reduction of GO-AuNRs to GN-AuNRs. Combined the high conductivity, large surface area, good adsorption capacity towards aromatic rings and high catalytic ability of graphene with the excellent electronic properties and adsorption capacity of AuNRs, the high sensitive methyl parathion sensor was fabricated with the GN-AuNRs nanocomposite. The limit of detection (LOD) of the proposed sensor was calculated to be 0.82 ng/mL, which was lower than many previously reported enzyme or nonenzyme-based sensors. In the meantime, the linear detection range of this sensor was from 10 to 500 ng/mL and 750 to 4000 ng/mL, which was also wider than many other enzyme or enzymeless sensors. Furthermore, the facile and green electrochemical reduction strategy provided here could also be used to construct more GN-based hybrids. And the GN-based hybrid might be a new and highly efficient SPE factor, which opens new opportunities for green, facile and sensitive analysis of

  3. Development and validation of a rapid HPLC method for the determination of cefdinir in beagle dog plasma integrated with an automatic on-line solid-phase extraction following protein precipitation in the 96-well plate format.

    Science.gov (United States)

    Li, Ji; Wang, Li; Chen, Zhao; Xie, Rui; Li, You; Hang, Taijun; Fan, Guorong

    2012-05-01

    The high-performance liquid chromatography (HPLC) coupled with on-line solid phase extraction (SPE) and ultraviolet (UV) detection was developed for determining cefdinir in beagle dog plasma. After simple pretreatment for plasma with 6% perchloric acid, a volume of 100 μL upper layer of the plasma sample was injected into the self-made on-line SPE column. The analytes were retained on the trap column (Lichrospher C(18), 4.6 mm × 37 mm, 25 μm), and the biological matrix was washed out with the solvent (20mM KH(2)PO(4) adjusted pH 3.0) at flow rate of 2 mL/min. By rotation of the switching valve, the target analytes could be eluted from trap column to analytical column in the back-flush mode by the mobile phase (methanol-acetonitrile-20mM KH(2)PO(4) adjusted pH 3.0, 11.25:6.75:82, v/v/v) at flow rate of 1.5 mL/min, and then separated on the analytical column (Ultimate XB-C(18), 4.6 mm × 50 mm, 5 μm). The complete cycle of the on-line SPE preconcentration, purification and HPLC separation of the analytes was 4 min. The UV detection was performed at 286 nm. The calibration curves showed excellent linear relationship (R(2)=0.9995) over the concentration range of 0.05-50 μg/mL. The optimized method showed good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This method was successfully applied to quantify cefdinir in beagle dog plasma to support the pre-clinical pharmacokinetic trial. Copyright © 2012. Published by Elsevier B.V.

  4. Molecular Dynamics Simulation of Mahkota Dewa (Phaleria Macrocarpa) Extract in Subcritical Water Extraction Process

    Science.gov (United States)

    Hashim, N. A.; Mudalip, S. K. Abdul; Harun, N.; Che Man, R.; Sulaiman, S. Z.; Arshad, Z. I. M.; Shaarani, S. M.

    2018-05-01

    Mahkota Dewa (Phaleria Macrocarpa), a good source of saponin, flavanoid, polyphenol, alkaloid, and mangiferin has an extensive range of medicinal effects. The intermolecular interactions between solute and solvents such as hydrogen bonding considered as an important factor that affect the extraction of bioactive compounds. In this work, molecular dynamics simulation was performed to elucidate the hydrogen bonding exists between Mahkota Dewa extracts and water during subcritical extraction process. A bioactive compound in the Mahkota Dewa extract, namely mangiferin was selected as a model compound. The simulation was performed at 373 K and 4.0 MPa using COMPASS force field and Ewald summation method available in Material Studio 7.0 simulation package. The radial distribution functions (RDF) between mangiferin and water signify the presence of hydrogen bonding in the extraction process. The simulation of the binary mixture of mangiferin:water shows that strong hydrogen bonding was formed. It is suggested that, the intermolecular interaction between OH2O••HMR4(OH1) has been identified to be responsible for the mangiferin extraction process.

  5. Metal-organic framework MIL-101 as sorbent based on double-pumps controlled on-line solid-phase extraction coupled with high-performance liquid chromatography for the determination of flavonoids in environmental water samples.

    Science.gov (United States)

    Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang

    2016-10-01

    A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    Science.gov (United States)

    Slobodník, J; Oztezkizan, O; Lingeman, H; Brinkman, U A

    1996-10-25

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 l samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (> 2 l for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n = 3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 microgram/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10 x 2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 microgram

  7. Extracting neuronal functional network dynamics via adaptive Granger causality analysis.

    Science.gov (United States)

    Sheikhattar, Alireza; Miran, Sina; Liu, Ji; Fritz, Jonathan B; Shamma, Shihab A; Kanold, Patrick O; Babadi, Behtash

    2018-04-24

    Quantifying the functional relations between the nodes in a network based on local observations is a key challenge in studying complex systems. Most existing time series analysis techniques for this purpose provide static estimates of the network properties, pertain to stationary Gaussian data, or do not take into account the ubiquitous sparsity in the underlying functional networks. When applied to spike recordings from neuronal ensembles undergoing rapid task-dependent dynamics, they thus hinder a precise statistical characterization of the dynamic neuronal functional networks underlying adaptive behavior. We develop a dynamic estimation and inference paradigm for extracting functional neuronal network dynamics in the sense of Granger, by integrating techniques from adaptive filtering, compressed sensing, point process theory, and high-dimensional statistics. We demonstrate the utility of our proposed paradigm through theoretical analysis, algorithm development, and application to synthetic and real data. Application of our techniques to two-photon Ca 2+ imaging experiments from the mouse auditory cortex reveals unique features of the functional neuronal network structures underlying spontaneous activity at unprecedented spatiotemporal resolution. Our analysis of simultaneous recordings from the ferret auditory and prefrontal cortical areas suggests evidence for the role of rapid top-down and bottom-up functional dynamics across these areas involved in robust attentive behavior.

  8. Dynamic Trajectory Extraction from Stereo Vision Using Fuzzy Clustering

    Science.gov (United States)

    Onishi, Masaki; Yoda, Ikushi

    In recent years, many human tracking researches have been proposed in order to analyze human dynamic trajectory. These researches are general technology applicable to various fields, such as customer purchase analysis in a shopping environment and safety control in a (railroad) crossing. In this paper, we present a new approach for tracking human positions by stereo image. We use the framework of two-stepped clustering with k-means method and fuzzy clustering to detect human regions. In the initial clustering, k-means method makes middle clusters from objective features extracted by stereo vision at high speed. In the last clustering, c-means fuzzy method cluster middle clusters based on attributes into human regions. Our proposed method can be correctly clustered by expressing ambiguity using fuzzy clustering, even when many people are close to each other. The validity of our technique was evaluated with the experiment of trajectories extraction of doctors and nurses in an emergency room of a hospital.

  9. Use of on-line supercritical fluid extraction-supercritical fluid chromatography/tandem mass spectrometry to analyze disease biomarkers in dried serum spots compared with serum analysis using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Suzuki, Makoto; Nishiumi, Shin; Kobayashi, Takashi; Sakai, Arata; Iwata, Yosuke; Uchikata, Takato; Izumi, Yoshihiro; Azuma, Takeshi; Bamba, Takeshi; Yoshida, Masaru

    2017-05-30

    The analytical stability and throughput of biomarker assays based on dried serum spots (DSS) are strongly dependent on the extraction process and determination method. In the present study, an on-line system based on supercritical fluid extraction-supercritical fluid chromatography coupled with tandem mass spectrometry (SFE-SFC/MS/MS) was established for analyzing the levels of disease biomarkers in DSS. The chromatographic conditions were investigated using the ODS-EP, diol, and SIL-100A columns. Then, we optimized the SFE-SFC/MS/MS method using the diol column, focusing on candidate biomarkers of oral, colorectal, and pancreatic cancer that were identified using liquid chromatography (LC)/MS/MS. By using this system, four hydrophilic metabolites and 17 hydrophobic metabolites were simultaneously detected within 15 min. In an experiment involving clinical samples, PC 16:0-18:2/16:1-18:1 exhibited 93.8% sensitivity and 64.3% specificity, whereas PC 17:1-18:1/17:0-18:2 showed 81.3% sensitivity and 92.9% specificity for detecting oral cancer. In addition, assessments of the creatine levels demonstrated 92.3% sensitivity and 78.6% specificity for detecting colorectal cancer. The results of this study indicate that our method has great potential for clinical diagnosis and would be suitable for large-scale screening. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Extracting the diffusion tensor from molecular dynamics simulation with Milestoning

    International Nuclear Information System (INIS)

    Mugnai, Mauro L.; Elber, Ron

    2015-01-01

    We propose an algorithm to extract the diffusion tensor from Molecular Dynamics simulations with Milestoning. A Kramers-Moyal expansion of a discrete master equation, which is the Markovian limit of the Milestoning theory, determines the diffusion tensor. To test the algorithm, we analyze overdamped Langevin trajectories and recover a multidimensional Fokker-Planck equation. The recovery process determines the flux through a mesh and estimates local kinetic parameters. Rate coefficients are converted to the derivatives of the potential of mean force and to coordinate dependent diffusion tensor. We illustrate the computation on simple models and on an atomically detailed system—the diffusion along the backbone torsions of a solvated alanine dipeptide

  11. A simple and highly sensitive on-line column extraction liquid chromatography-tandem mass spectrometry method for the determination of protein-unbound tacrolimus in human plasma samples.

    Science.gov (United States)

    Bittersohl, Heike; Schniedewind, Björn; Christians, Uwe; Luppa, Peter B

    2018-04-27

    Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP ® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Simultaneous multi-mycotoxin determination in nutmeg by ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection.

    Science.gov (United States)

    Kong, Wei-Jun; Liu, Shu-Yu; Qiu, Feng; Xiao, Xiao-He; Yang, Mei-Hua

    2013-05-07

    A simple and sensitive analytical method based on ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with high performance liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection (USLE-IAC-HPLC-PCD-FLD) has been developed for simultaneous multi-mycotoxin determination of aflatoxins B1, B2, G1, G2 (AFB1, AFB2, AFG1, AFG2) and ochratoxin A (OTA) in 13 edible and medicinal nutmeg samples marketed in China. AFs and OTA were extracted from nutmeg samples by ultrasonication using a methanol : water (80 : 20, v/v) solution, followed by an IAC clean-up step. Different USL extraction conditions, pre-processing ways for nutmeg sample and clean-up columns for mycotoxins, as well as HPLC-PCD-FLD parameters (mobile phase, column temperature, elution procedure, excitation and emission wavelengths) were optimized. This method, which was appraised for analyzing nutmeg samples, showed satisfactory results with reference to limits of detection (LODs) (from 0.02 to 0.25 μg kg(-1)), limits of quantification (LOQs) (from 0.06 to 0.8 μg kg(-1)), linear ranges (up to 30 ng mL(-1) for AFB1, AFG1 and OTA and 9 ng mL(-1) for AFB2 and AFG2), intra- and inter-day variability (all application of developed method in nutmeg samples have elucidated that four samples were detected with contamination of AFs and one with OTA. AFB1 was the most frequently found mycotoxin in 30.8% of nutmeg samples at contamination levels of 0.73-16.31 μg kg(-1). At least two different mycotoxins were co-occurred in three samples, and three AFs were simultaneously detected in one sample.

  13. On-line filtering

    International Nuclear Information System (INIS)

    Verkerk, C.

    1978-01-01

    Present day electronic detectors used in high energy physics make it possible to obtain high event rates and it is likely that future experiments will face even higher data rates than at present. The complexity of the apparatus increases very rapidly with time and also the criteria for selecting desired events become more and more complex. So complex in fact that the fast trigger system cannot be designed to fully cope with it. The interesting events become thus contaminated with multitudes of uninteresting ones. To distinguish the 'good' events from the often overwhelming background of other events one has to resort to computing techniques. Normally this selection is made in the first part of the analysis of the events, analysis normally performed on a powerful scientific computer. This implies however that many uninteresting or background events have to be recorded during the experiment for subsequent analysis. A number of undesired consequences result; and these constitute a sufficient reason for trying to perform the selection at an earlier stage, in fact ideally before the events are recorded on magnetic tape. This early selection is called 'on-line filtering' and it is the topic of the present lectures. (Auth.)

  14. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  15. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  16. Simple and quick determination of analgesics and other contaminants of emerging concern in environmental waters by on-line solid phase extraction coupled to liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ferrer-Aguirre, Alejandra; Romero-González, Roberto; Vidal, J L Martínez; Frenich, Antonia Garrido

    2016-05-13

    A simple and quick analytical method has been developed for the determination of pharmaceutical compounds in water. An on-line solid-phase extraction (SPE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been optimized to determine 7 contaminants of emerging concern in environmental waters at ngL(-1) levels. This procedure requires minimal sample handling and small sample volume (900μL) with a total running time of 18min. Several SPE parameters were evaluated and optimized in order to achieve a high sample throughput. Therefore sample volume, carryover and reusability of the cartridges were evaluated. Performance characteristics were evaluated and good linearity was obtained (R(2)>0.98). Recoveries were evaluated in spiked samples at three concentrations and the values ranged from 71 to 104%. Intra and inter-day precision was lower than 10 and 13% respectively. Limits of quantification were equal to or lower than 10ngL(-1), except for 1,7-dimethylxanthine (20ngL(-1)) and ibuprofen (50ngL(-1)). The method was applied to 20 environmental water samples, and ibuprofen was the compound most widely detected at concentrations up to 42.06μgL(-1), whereas the other compounds were detected in fewer samples at lower concentrations (up to 15.99μgL(-1)). Copyright © 2016 Elsevier B.V. All rights reserved.

  17. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    Purpose/Objective: The purpose of this presentation is to review the physics of imaging with high energy x-ray beams; examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine errors in patient positioning quantitatively; and discuss some of the ways that portal imaging has been incorporated into routine clinical practice. Verification of patient positioning has always been an important aspect of external beam radiation therapy. Checks of patient positioning have generally been done with film, however, film suffers from a number of drawbacks, such as poor image display and delays due to film development. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems, which are intended to overcome the limitations of portal films. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The fundamental factors which limit image quality and the characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same

  18. On-line monitoring of CO2 production in Lactococcus lactis during physiological pH decrease using membrane inlet mass spectrometry with dynamic pH calibration.

    Science.gov (United States)

    Andersen, Ann Zahle; Lauritsen, Frants Roager; Olsen, Lars Folke

    2005-12-20

    Monitoring CO2 production in systems, where pH is changing with time is hampered by the chemical behavior and pH-dependent volatility of this compound. In this article, we present the first method where the concentration and production rate of dissolved CO2 can be monitored directly, continuously, and quantitatively under conditions where pH changes rapidly ( approximately 2 units in 15 min). The method corrects membrane inlet mass spectrometry (MIMS) measurements of CO2 for pH dependency using on-line pH analysis and an experimentally established calibration model. It is valid within the pH range of 3.5 to 7, despite pH-dependent calibration constants that vary in a non-linear fashion with more than a factor of 3 in this interval. The method made it possible to determine the carbon dioxide production during Lactococcus lactis fermentations, where pH drops up to 3 units during the fermentation. The accuracy was approximately 5%. We used the method to investigate the effect of initial extracellular pH on carbon dioxide production during anarobic glucose fermentation by non-growing Lactocoocus lactis and demonstrated that the carbon dioxide production rate increases considerably, when the initial pH was increased from 6 to 6.8. (c) 2005 Wiley Periodicals, Inc.

  19. An algorithm for on-line price discrimination

    NARCIS (Netherlands)

    D.D.B. van Bragt; D.J.A. Somefun (Koye); E. Kutschinski; J.A. La Poutré (Han)

    2002-01-01

    textabstractThe combination of on-line dynamic pricing with price discrimination can be very beneficial for firms operating on the Internet. We therefore develop an on-line dynamic pricing algorithm that can adjust the price schedule for a good or service on behalf of a firm. This algorithm (a

  20. Application of learning from examples methods for on-line dynamic security assessment of electric power systems - state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Pecas Lopes, J.A. [Universidade do Porto, Porto (Portugal). Faculdade de Engenharia] Hatziargyriou, Nikos D. [National Technical University of Athens, Athens (Greece)

    1994-12-31

    This paper provides an overview of the application of `learning from examples` techniques like pattern recognition, artificial neural networks and decision trees, when used for fast dynamic security assessment. Problems concerning the system security evaluation relatively to transient stability and voltage stability are addressed with more details and references to research works in this field are briefly described. (author) 44 refs., 3 tabs.

  1. On line routing per mobile phone

    DEFF Research Database (Denmark)

    Bieding, Thomas; Görtz, Simon; Klose, Andreas

    2009-01-01

    On-line routing is concerned with building vehicle routes in an ongoing fashion in such a way that customer requests arriving dynamically in time are efficiently and effectively served. An indispensable prerequisite for applying on-line routing methods is mobile communication technology....... Additionally it is of utmost importance that the employed communication system is suitable integrated with the firm’s enterprise application system and business processes. On basis of a case study, we describe in this paper a system that is cheap and easy to implement due to the use of simple mobile phones...

  2. Skin tumor area extraction using an improved dynamic programming approach.

    Science.gov (United States)

    Abbas, Qaisar; Celebi, M E; Fondón García, Irene

    2012-05-01

    Border (B) description of melanoma and other pigmented skin lesions is one of the most important tasks for the clinical diagnosis of dermoscopy images using the ABCD rule. For an accurate description of the border, there must be an effective skin tumor area extraction (STAE) method. However, this task is complicated due to uneven illumination, artifacts present in the lesions and smooth areas or fuzzy borders of the desired regions. In this paper, a novel STAE algorithm based on improved dynamic programming (IDP) is presented. The STAE technique consists of the following four steps: color space transform, pre-processing, rough tumor area detection and refinement of the segmented area. The procedure is performed in the CIE L(*) a(*) b(*) color space, which is approximately uniform and is therefore related to dermatologist's perception. After pre-processing the skin lesions to reduce artifacts, the DP algorithm is improved by introducing a local cost function, which is based on color and texture weights. The STAE method is tested on a total of 100 dermoscopic images. In order to compare the performance of STAE with other state-of-the-art algorithms, various statistical measures based on dermatologist-drawn borders are utilized as a ground truth. The proposed method outperforms the others with a sensitivity of 96.64%, a specificity of 98.14% and an error probability of 5.23%. The results demonstrate that this STAE method by IDP is an effective solution when compared with other state-of-the-art segmentation techniques. The proposed method can accurately extract tumor borders in dermoscopy images. © 2011 John Wiley & Sons A/S.

  3. Fast and simple screening for the simultaneous analysis of seven metabolites derived from five volatile organic compounds in human urine using on-line solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chiang, Wen-Chieh; Chen, Chao-Yu; Lee, Ting-Chen; Lee, Hui-Ling; Lin, Yu-Wen

    2015-01-01

    Recently, the International Agency for Research on cancer classified outdoor air pollution and particulate matter from outdoor air pollution as carcinogenic to humans (IARC Group 1), based on sufficient evidence of carcinogenicity in humans and experimental animals and strong mechanistic evidence. In particular, a wide variety of volatile organic compounds (VOCs) are volatized or released into the atmosphere and can become ubiquitous, as they originate from many different natural and anthropogenic sources, such as paints, pesticides, vehicle exhausts, cooking fumes, and tobacco smoke. Humans may be exposed to VOCs through inhalation, ingestion, or dermal contact, which may increase the risk of leukemia, birth defects, neurocognitive impairment, and cancer. Therefore, the focus of this study was the development of a simple, effective and rapid sample preparation method for the simultaneous determination of seven metabolites (6 mercaptic acids+t,t-muconic acid) derived from five VOCs (acrylamide, 1,3-butadiene, acrylonitrile, benzene, and xylene) in human urine by using automated on-line solid-phase extraction (SPE) coupled with liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS). An aliquot of each diluted urinary sample was directly injected into an autosampler through a trap column to reduce contamination, and then the retained target compounds were eluted by back-flush mode into an analytical column for separation. Negative electrospray ionization tandem mass spectrometry was utilized for quantification. The coefficients of correlation (r(2)) for the calibration curves were greater than 0.995. Reproducibility was assessed by the precision and accuracy of intra-day and inter-day precision, which showed results for coefficient of variation (CV) that were low 0.9 to 6.6% and 3.7 to 8.5%, respectively, and results for recovery that ranged from 90.8 to 108.9% and 92.1 to 107.7%, respectively. The limits of detection (LOD) and limits of

  4. On a possible mechanism of the brain for responding to dynamical features extracted from input signals

    International Nuclear Information System (INIS)

    Liu Zengrong; Chen Guanrong

    2003-01-01

    Based on the general theory of nonlinear dynamical systems, a possible mechanism for responding to some dynamical features extracted from input signals in brain activities is described and discussed. This mechanism is first converted to a nonlinear dynamical configuration--a generalized synchronization of complex dynamical systems. Then, some general conditions for achieving such synchronizations are derived. It is shown that dynamical systems have potentials of producing different responses for different features extracted from various input signals, which may be used to describe brain activities. For illustration, some numerical examples are given with simulation figures

  5. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  6. On-line Learning of Prototypes and Principal Components

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Hölzer, M.; Reents, G.; Schlösser, E.; Saad, David

    1998-01-01

    We review our recent investigation of on-line unsupervised learning from high-dimensional structured data. First, on-line competitive learning is studied as a method for the identification of prototype vectors from overlapping clusters of examples. Specifically, we analyse the dynamics of the

  7. Evaluation of degree of readsorption of radionuclides during sequential extraction in soil: comparison between batch and dynamic extraction systems

    DEFF Research Database (Denmark)

    Petersen, Roongrat; Hansen, Elo Harald; Hou, Xiaolin

    . However, the techniques have an important problem with redistribution as a result of readsorption of dissolved analytes onto the remaining solids phases during extraction. Many authors have demonstrated the readsorption problem and inaccuracy from it. In our previous work, a dynamic extraction system......Sequential extraction techniques have been widely used to fractionate metals in solid samples (soils, sediments, solid wastes, etc.) due to their leachability. The results are useful for obtaining information about bioavailability, potential mobility and transport of element in natural environments...... developed in our laboratory for heavy metal fractionation has shown the reduction of readsorption problem in comparison with the batch techniques. Moreover, the system shows many advantages over the batch system such as speed of extraction, simple procedure, fully automatic, less risk of contamination...

  8. CERN Video News on line

    CERN Multimedia

    2003-01-01

    The latest CERN video news is on line. In this issue : an interview with the Director General and reports on the new home for the DELPHI barrel and the CERN firemen's spectacular training programme. There's also a vintage video news clip from 1954. See: www.cern.ch/video or Bulletin web page

  9. Statistical properties of compartmental model parameters extracted from dynamic positron emission tomography experiments

    International Nuclear Information System (INIS)

    Mazoyer, B.M.; Huesman, R.H.; Budinger, T.F.; Knittel, B.L.

    1986-01-01

    Over the past years a major focus of research in physiologic studies employing tracers has been the computer implementation of mathematical methods of kinetic modeling for extracting the desired physiological parameters from tomographically derived data. A study is reported of factors that affect the statistical properties of compartmental model parameters extracted from dynamic positron emission tomography (PET) experiments

  10. The Temporal Dynamics of Regularity Extraction in Non-Human Primates

    Science.gov (United States)

    Minier, Laure; Fagot, Joël; Rey, Arnaud

    2016-01-01

    Extracting the regularities of our environment is one of our core cognitive abilities. To study the fine-grained dynamics of the extraction of embedded regularities, a method combining the advantages of the artificial language paradigm (Saffran, Aslin, & Newport, [Saffran, J. R., 1996]) and the serial response time task (Nissen & Bullemer,…

  11. Dynamic Modeling of Pectin Extraction for Monitoring and Optimisation

    DEFF Research Database (Denmark)

    Andersen, Nina M.; Santacoloma, Paloma A.; Gernaey, Krist

    Pectin is used as an additive in many food and pharmaceutical products to modify the rheological properties of the product [1]. Commercial pectin extraction is a batch operation with several tanks that can feed continuously the downstream processing.The variability of the raw material is a contin...

  12. Extractive Industries and Indigenous Peoples: A Changing Dynamic?

    Science.gov (United States)

    O'Faircheallaigh, Ciaran

    2013-01-01

    Indigenous peoples and other rural or remote populations often bear the social and environmental cost of extractive industries while obtaining little of the wealth they generate. Recent developments including national and international recognition of Indigenous rights, and the growth of "corporate social responsibility" initiatives among…

  13. Dynamic materials accounting for solvent-extraction systems

    Energy Technology Data Exchange (ETDEWEB)

    Cobb, D.D.; Ostenak, C.A.

    1979-01-01

    Methods for estimating nuclear materials inventories in solvent-extraction contactors are being developed. These methods employ chemical models and available process measurements. Comparisons of model calculations and experimental data for mixer-settlers and pulsed columns indicate that this approach should be adequate for effective near-real-time materials accounting in nuclear fuels reprocessing plants.

  14. Dynamic materials accounting for solvent-extraction systems

    International Nuclear Information System (INIS)

    Cobb, D.D.; Ostenak, C.A.

    1979-01-01

    Methods for estimating nuclear materials inventories in solvent-extraction contactors are being developed. These methods employ chemical models and available process measurements. Comparisons of model calculations and experimental data for mixer-settlers and pulsed columns indicate that this approach should be adequate for effective near-real-time materials accounting in nuclear fuels reprocessing plants

  15. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  16. Extracting Markov Models of Peptide Conformational Dynamics from Simulation Data.

    Science.gov (United States)

    Schultheis, Verena; Hirschberger, Thomas; Carstens, Heiko; Tavan, Paul

    2005-07-01

    A high-dimensional time series obtained by simulating a complex and stochastic dynamical system (like a peptide in solution) may code an underlying multiple-state Markov process. We present a computational approach to most plausibly identify and reconstruct this process from the simulated trajectory. Using a mixture of normal distributions we first construct a maximum likelihood estimate of the point density associated with this time series and thus obtain a density-oriented partition of the data space. This discretization allows us to estimate the transfer operator as a matrix of moderate dimension at sufficient statistics. A nonlinear dynamics involving that matrix and, alternatively, a deterministic coarse-graining procedure are employed to construct respective hierarchies of Markov models, from which the model most plausibly mapping the generating stochastic process is selected by consideration of certain observables. Within both procedures the data are classified in terms of prototypical points, the conformations, marking the various Markov states. As a typical example, the approach is applied to analyze the conformational dynamics of a tripeptide in solution. The corresponding high-dimensional time series has been obtained from an extended molecular dynamics simulation.

  17. On line ultrasonic integrated backscatter

    International Nuclear Information System (INIS)

    Landini, L.; Picano, E.; Mazzarisi, A.; Santarelli, F.; Benassi, A.; De Pieri, G.

    1988-01-01

    A new equipment for on-line evaluation of index based on two-dimensional integrated backscatter from ultrasonic images is described. The new equipment is fully integrated into a B-mode ultrasonic apparatus which provides a simultaneous display of conventional information together with parameters of tissue characterization. The system has been tested with a backscattering model of microbubbles in polysaccharide solution, characterized by a physiological exponential time decay. An exponential fitting to the experimental data was performed which yielded r=0.95

  18. Development of a system for simultaneous - sequential determinations of major and minor actinides (Th, Np, U, Pu, Am, Cm) by on-line extraction chromatography - ion concentration - inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Trivellone, E.; Mariani, M.; Carlos-Marquez, R.; Aldave de las Heras, L.; Betti, M.; )

    2009-01-01

    Full text: Because of the great complexity and time consuming of traditional methods for actinides determination, a procedure for their simultaneous and sequential separation and quantification was developed. A complete circuit constituted by three analytical chromatographic columns packed with TEVA, UTEVA and TRU resins (Eichrom Inc) for retention of tetra-, hexa- and tri-valent actinides and three cation concentrator columns TCC-II (from Dionex Corporation) connected by six (4-way and 6-way) valves is coupled on-line to an ICPMS detector. The use of TCC-II columns just prior of the ICPMS determination allows to improve sensitivity and detection limits down to the ng/l level. The use of a coupled HPLC to an ICPMS system enables the complete analysis of all the six actinides in almost 2 hours. (author)

  19. On-line moisture analysis

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Mijak, D.G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk material. Nuclear-based analysers measure the total hydrogen content in the sample and do not differentiate between free and combined moisture. Such analysers may also be sensitive to material presentation and elemental composition. Very low frequency electromagnetic probes, such as capacitance or conductance probes, operate in the frequency region where the DC conductivity dominates much of the response, which is a function not only of moisture content but also of ionic composition and chemistry. These problems are overcome using microwave transmission techniques, which also have the following advantages, as a true bulk moisture analysis is obtained, because a high percentage of the bulk material is analysed; the moisture estimate is mostly insensitive to any biased presentation of moisture, for example due to stratification of bulk material with different moisture content and because no physical contact is made between the sensor and the bulk material. This is

  20. Automatic extraction of forward stroke volume using dynamic 11C-acetate PET/CT

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    Objectives: Dynamic PET with 11C-acetate can be used to quantify myocardial blood flow and oxidative metabolism, the latter of which is used to calculate myocardial external efficiency (MEE). Calculation of MEE requires forward stroke volume (FSV) data. FSV is affected by cardiac loading conditions......, potentially introducing bias if measured with a separate modality. The aim of this study was to develop and validate methods for automatically extracting FSV directly from the dynamic PET used for measuring oxidative metabolism. Methods: 16 subjects underwent a dynamic 27 min PET scan on a Siemens Biograph...... TruePoint 64 PET/CT scanner after bolus injection of 399±27 MBq of 11C-acetate. The LV-aortic time-activity curve (TAC) was extracted automatically from dynamic PET data using cluster analysis. The first-pass peak was derived by automatic extrapolation of the down-slope of the TAC. FSV...

  1. Development of an on-line solid phase extraction ultra-high-performance liquid chromatography technique coupled to tandem mass spectrometry for quantification of bisphenol S and bisphenol S glucuronide: Applicability to toxicokinetic investigations.

    Science.gov (United States)

    Grandin, Flore; Picard-Hagen, Nicole; Gayrard, Véronique; Puel, Sylvie; Viguié, Catherine; Toutain, Pierre-Louis; Debrauwer, Laurent; Lacroix, Marlène Z

    2017-12-01

    Regulatory measures and public concerns regarding bisphenol A (BPA) have led to its replacement by structural analogues, such as Bisphenol S (BPS), in consumer products. At present, no toxicokinetic investigations have been conducted to assess the factors determining human internal exposure to BPS for subsequent risk assessment. Toxicokinetic studies require reliable analytical methods to measure the plasma concentrations of BPS and its main conjugated metabolite, BPS-glucuronide (BPS-G). An efficient on-line SPE-UPLC-MS/MS method for the simultaneous quantification of BPS and BPS-G in ovine plasma was therefore developed and validated in accordance with the European Medicines Agency guidelines for bioanalytical method validation. This method has a limit of quantification of 3ngmL -1 for BPS and 10ngmL -1 for BPS-G, an analytical capacity of 200 samples per day, and is particularly well suited to toxicokinetic studies. Use of this method in toxicokinetic studies in sheep showed that BPS, like BPA, is efficiently metabolized into its glucuronide form. However, the clearances and distributions of BPS and BPS-G were lower than those of the corresponding unconjugated and glucuroconjugated forms of BPA. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. On-line separation and preconcentration of lead(II) by solid-phase extraction using activated carbon loaded with xylenol orange and its determination by flame atomic absorption spectrometry.

    Science.gov (United States)

    Ensafi, Ali A; Shiraz, A Zendegi

    2008-02-11

    Activated carbon loaded with xylenol orange in a mini-column was used for the highly selective separation and preconcentration of Pb(II) ions. An on-line system for enrichment and the determination of Pb(II) was carried out on flame atomic absorption spectrometry. The conditions of preconcentration and quantitative recovery of Pb(II) from diluted solution, such as pH of aqueous phase, amount of the sorbent, volume of the solutions and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, Pb(II) in an aqueous sample was concentrated about 200-fold and the detection limit was 0.4 ng mL(-1) Pb(II). The adsorption capacity of the solid phase was 0.20mg of lead per one gram of the modified activated carbon. The modified activated carbon is stable for several treatments of sample solutions without the need for using any chemical reagent. The recovery of lead(II) from river water, waste water, tap water, and in the following reference materials: SRM 2711 Montana soil and GBW-07605 tea were obtained in the range of 97-104% by the proposed method.

  3. On-line separation and preconcentration of lead(II) by solid-phase extraction using activated carbon loaded with xylenol orange and its determination by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Ensafi, Ali A.; Shiraz, A. Zendegi

    2008-01-01

    Activated carbon loaded with xylenol orange in a mini-column was used for the highly selective separation and preconcentration of Pb(II) ions. An on-line system for enrichment and the determination of Pb(II) was carried out on flame atomic absorption spectrometry. The conditions of preconcentration and quantitative recovery of Pb(II) from diluted solution, such as pH of aqueous phase, amount of the sorbent, volume of the solutions and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, Pb(II) in an aqueous sample was concentrated about 200-fold and the detection limit was 0.4 ng mL -1 Pb(II). The adsorption capacity of the solid phase was 0.20 mg of lead per one gram of the modified activated carbon. The modified activated carbon is stable for several treatments of sample solutions without the need for using any chemical reagent. The recovery of lead(II) from river water, waste water, tap water, and in the following reference materials: SRM 2711 Montana soil and GBW-07605 tea were obtained in the range of 97-104% by the proposed method

  4. On-line separation and preconcentration of lead(II) by solid-phase extraction using activated carbon loaded with xylenol orange and its determination by flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A. [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)], E-mail: Ensafi@cc.iut.ac.ir; Shiraz, A. Zendegi [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2008-02-11

    Activated carbon loaded with xylenol orange in a mini-column was used for the highly selective separation and preconcentration of Pb(II) ions. An on-line system for enrichment and the determination of Pb(II) was carried out on flame atomic absorption spectrometry. The conditions of preconcentration and quantitative recovery of Pb(II) from diluted solution, such as pH of aqueous phase, amount of the sorbent, volume of the solutions and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, Pb(II) in an aqueous sample was concentrated about 200-fold and the detection limit was 0.4 ng mL{sup -1} Pb(II). The adsorption capacity of the solid phase was 0.20 mg of lead per one gram of the modified activated carbon. The modified activated carbon is stable for several treatments of sample solutions without the need for using any chemical reagent. The recovery of lead(II) from river water, waste water, tap water, and in the following reference materials: SRM 2711 Montana soil and GBW-07605 tea were obtained in the range of 97-104% by the proposed method.

  5. Automatic extraction of forward stroke volume using dynamic PET/CT

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    Background: Dynamic PET can be used to extract forward stroke volume (FSV) by the indicator dilution principle. The technique employed can be automated and is in theory independent on the tracer used and may therefore be added to any dynamic cardiac PET protocol. The aim of this study...... was to validate automated methods for extracting FSV directly from dynamic PET studies for two different tracers and to examine potential scanner hardware bias. Methods: 21 subjects underwent a dynamic 27 min 11C-acetate PET scan on a Siemens Biograph TruePoint 64 PET/CT scanner (scanner I). In addition, 8...... subjects underwent a dynamic 6 min 15O-water PET scan followed by a 27 min 11C-acetate PET scan on a GE Discovery ST PET/CT scanner (scanner II). The LV-aortic time-activity curve (TAC) was extracted automatically from dynamic PET data using cluster analysis. The first-pass peak was isolated by automatic...

  6. A simulation of the SDC on-line processing farm

    International Nuclear Information System (INIS)

    Wang, C.; Chen, Y.; Dorenbosch, J.; Lee, J.; Sayle, R.

    1993-10-01

    In the Solenoidal Detector Collaboration (SDC) data acquisition system (DAQ), an enormous amount of data flows into a processor farm for extraction of interesting physics events. To design an efficient on-line filter, the operations in the farm must be carefully modeled. The authors present a simulation model developed at the Superconducting Super Collider Laboratory which efficiently allocates physics events to the farm

  7. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  8. Automatic extraction of forward stroke volume using dynamic PET/CT

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik Stubkjær

    2015-01-01

    Background The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. Methods 35 subjects underwent...... a dynamic 11 C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic 15 O-water PET and 11 C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically...... from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase...

  9. Multiaperture ion beam extraction from gas-dynamic electron cyclotron resonance source of multicharged ions

    International Nuclear Information System (INIS)

    Sidorov, A.; Dorf, M.; Zorin, V.; Bokhanov, A.; Izotov, I.; Razin, S.; Skalyga, V.; Rossbach, J.; Spaedtke, P.; Balabaev, A.

    2008-01-01

    Electron cyclotron resonance ion source with quasi-gas-dynamic regime of plasma confinement (ReGIS), constructed at the Institute of Applied Physics, Russia, provides opportunities for extracting intense and high-brightness multicharged ion beams. Despite the short plasma lifetime in a magnetic trap of a ReGIS, the degree of multiple ionization may be significantly enhanced by the increase in power and frequency of the applied microwave radiation. The present work is focused on studying the intense beam quality of this source by the pepper-pot method. A single beamlet emittance measured by the pepper-pot method was found to be ∼70 π mm mrad, and the total extracted beam current obtained at 14 kV extraction voltage was ∼25 mA. The results of the numerical simulations of ion beam extraction are found to be in good agreement with experimental data

  10. Box-Behnken design for optimum extraction of biogenetic chemicals from P. lanceolata with an energy audit (thermal × microwave × acoustic): a case study of HPTLC determination with additional specificity using on-line/off-line coupling with DAD/NIR/ESI-MS.

    Science.gov (United States)

    Srivastava, Pooja; Ajayakumar, P V; Shanker, Karuna

    2014-01-01

    The genus Pluchea comprises about 80 species distributed worldwide, out of them, only Pluchea lanceolata (DC.) Oliv. & Hiern, is used extensively in the traditional system of India. No chromatographic method is available for its quality. To perform the energy audit for the extraction of biogenetic pentacyclic triterpene, its acetate and sterol from P. lanceolata utilising organic and four alternative solvents. Additionally to resolve the uncertainty of TLC determination, on-line/off-line coupling with a diode-array detector (DAD), and near-infrared (NIR) and electrospray ionisation (ESI) MS was introduced. The extraction of taraxasterol (Tx), taraxasterol acetate (TxAc) and stigmasterol (St) from P. lanceolata was performed using three energy modes. The effects of different operating parameters were studied for optimum extraction yield using the design of experiments, that is, the central composite design and Box-Behnken design. In addition to the retention factor (Rf ) and visible spectral matching, two additional optical spectroscopic techniques, that is, NIR and ESI-MS, were applied for extended specificity. The method was developed for Tx, TxAc and St determination using HPTLC at 645 nm. The optimum extraction yield of targeted compounds was found to be higher with organic solvents than eco-friendly surfactants. The pulse ultrasonic assisted extraction (PUAE) has resulted in optimum extraction of compounds comparable to hot extraction. Both NIR and ESI-MS provided extended specificity in determination. The 5/1-PUAE was determined to be effective, reproducible, simple and energy efficient for the determination of Tx, TxAc and St in P. lanceolata. The offline coupling of NIR and ESI-MS with HPTLC led to considerable improvement in specificity. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Quantitative Analysis of Bioactive Compounds from Aromatic Plants by Means of Dynamic Headspace Extraction and Multiple Headspace Extraction-Gas Chromatography-Mass Spectrometry

    NARCIS (Netherlands)

    Omar, Jone; Olivares, Maitane; Alonso, Ibone; Vallejo, Asier; Aizpurua-Olaizola, Oier; Etxebarria, Nestor

    2016-01-01

    Seven monoterpenes in 4 aromatic plants (sage, cardamom, lavender, and rosemary) were quantified in liquid extracts and directly in solid samples by means of dynamic headspace-gas chromatography-mass spectrometry (DHS-GC-MS) and multiple headspace extraction-gas chromatography-mass spectrometry

  12. Study on the dynamic holdup distribution of the pulsed extraction column

    International Nuclear Information System (INIS)

    Wang, S.; Chen, J.; Wu, Q.

    2013-01-01

    In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

  13. Study on the dynamic holdup distribution of the pulsed extraction column

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.; Chen, J.; Wu, Q. [Tsinghua University, Beijing 100084 (China)

    2013-07-01

    In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

  14. Extraction of Static and Dynamic Reservoir Operation Rules by Genetic Programming

    Directory of Open Access Journals (Sweden)

    Habib Akbari Alashti

    2014-11-01

    Full Text Available Considering the necessity of desirable operation of limited water resources and assuming the significant role of dams in controlling and consuming the surface waters, highlights the advantageous of suitable operation rules for optimal and sustainable operation of dams. This study investigates the hydroelectric supply of a one-reservoir system of Karoon3 using nonlinear programming (NLP, genetic algorithm (GA, genetic programming (GP and fixed length gen GP (FLGGP in real-time operation of dam considering two approaches of static and dynamic operation rules. In static operation rule, only one rule curve is extracted for all months in a year whereas in dynamic operation rule, monthly rule curves (12 rules are extracted for each month of a year. In addition, nonlinear decision rule (NLDR curves are considered, and the total deficiency function as the target (objective function have been used for evaluating the performance of each method and approach. Results show appropriate efficiency of GP and FLGGP methods in extracting operation rules in both approaches. Superiority of these methods to operation methods yielded by GA and NLP is 5%. Moreover, according to the results, it can be remarked that, FLGGP method is an alternative for GP method, whereas the GP method cannot be used due to its limitations. Comparison of two approaches of static and dynamic operation rules demonstrated the superiority of dynamic operation rule to static operation rule (about 10% and therefore this method has more capabilities in real-time operation of the reservoirs systems.

  15. On-line learning in radial basis functions networks

    OpenAIRE

    Freeman, Jason; Saad, David

    1997-01-01

    An analytic investigation of the average case learning and generalization properties of Radial Basis Function Networks (RBFs) is presented, utilising on-line gradient descent as the learning rule. The analytic method employed allows both the calculation of generalization error and the examination of the internal dynamics of the network. The generalization error and internal dynamics are then used to examine the role of the learning rate and the specialization of the hidden units, which gives ...

  16. Considerations in applying on-line IC techniques to BWR's

    International Nuclear Information System (INIS)

    Kaleda, R.J.

    1992-01-01

    Ion-Chromatography (IC) has moved from its traditional role as a laboratory analytical tool to a real time, dynamic, on-line measurement device to follow ppb and sub-ppb concentrations of deleterious impurities in nuclear power plants. Electric Power Research Institute (EPRI), individual utilities, and industry all have played significant roles in effecting the transition. This paper highlights considerations and the evolution in current on-line Ion Chromatography systems. The first applications of on-line techniques were demonstrated by General Electric (GE) under EPRI sponsorship at Rancho Seco (1980), Calvert Cliffs, and McGuire nuclear units. The primary use was for diagnostic purposes. Today the on-line IC applications have been expanded to include process control and routine plant monitoring. Current on-line IC's are innovative in design, promote operational simplicity, are modular for simplified maintenance and repair, and use field-proven components which enhance reliability. Conductivity detection with electronic or chemical suppression and spectrometric detection techniques are intermixed in applications. Remote multi-point sample systems have addressed memory effects. Early applications measured ionic species in the part per billion range. Today reliable part per trillion measurements are common for on-line systems. Current systems are meeting the challenge of EPRI guideline requirements. Today's on-line IC's, with programmed sampling systems, monitor fluid streams throughout a power plant, supplying data that can be trended, stored and retrieved easily. The on-line IC has come of age. Many technical challenges were overcome to achieve today's IC

  17. Adaptive Pulsed Laser Line Extraction for Terrain Reconstruction using a Dynamic Vision Sensor

    Directory of Open Access Journals (Sweden)

    Christian eBrandli

    2014-01-01

    Full Text Available Mobile robots need to know the terrain in which they are moving for path planning and obstacle avoidance. This paper proposes the combination of a bio-inspired, redundancy-suppressing dynamic vision sensor with a pulsed line laser to allow fast terrain reconstruction. A stable laser stripe extraction is achieved by exploiting the sensor’s ability to capture the temporal dynamics in a scene. An adaptive temporal filter for the sensor output allows a reliable reconstruction of 3D terrain surfaces. Laser stripe extractions up to pulsing frequencies of 500Hz were achieved using a line laser of 3mW at a distance of 45cm using an event-based algorithm that exploits the sparseness of the sensor output. As a proof of concept, unstructured rapid prototype terrain samples have been successfully reconstructed with an accuracy of 2mm.

  18. An integrated automatic system to evaluate U and Th dynamic lixiviation from solid matrices, and to extract/pre-concentrate leached analytes previous ICP-MS detection.

    Science.gov (United States)

    Ceballos, Melisa Rodas; García-Tenorio, Rafael; Estela, José Manuel; Cerdà, Víctor; Ferrer, Laura

    2017-12-01

    Leached fractions of U and Th from different environmental solid matrices were evaluated by an automatic system enabling the on-line lixiviation and extraction/pre-concentration of these two elements previous ICP-MS detection. UTEVA resin was used as selective extraction material. Ten leached fraction, using artificial rainwater (pH 5.4) as leaching agent, and a residual fraction were analyzed for each sample, allowing the study of behavior of U and Th in dynamic lixiviation conditions. Multivariate techniques have been employed for the efficient optimization of the independent variables that affect the lixiviation process. The system reached LODs of 0.1 and 0.7ngkg -1 of U and Th, respectively. The method was satisfactorily validated for three solid matrices, by the analysis of a soil reference material (IAEA-375), a certified sediment reference material (BCR- 320R) and a phosphogypsum reference material (MatControl CSN-CIEMAT 2008). Besides, environmental samples were analyzed, showing a similar behavior, i.e. the content of radionuclides decreases with the successive extractions. In all cases, the accumulative leached fraction of U and Th for different solid matrices studied (soil, sediment and phosphogypsum) were extremely low, up to 0.05% and 0.005% of U and Th, respectively. However, a great variability was observed in terms of mass concentration released, e.g. between 44 and 13,967ngUkg -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Sorption, desorption and extraction of uranium from some sands under dynamic conditions

    International Nuclear Information System (INIS)

    Palagyi, S.; Laciok, A.

    2006-01-01

    Sorption, desorption and extraction behavior of uranium in various fluvial sands of domestic origin were investigated in continuous dynamic column experiments. For the sorption of U(VI) an aqueous 10 -4 M UO 2 (NO 3 ) 2 solution was used at a flow rate of about 0.3 cm 3 /min. Desorption was carried out with demineralized water, and the extraction with 10 -2 M Na 2 CO 3 solution following desorption. The retardation coefficients (R) and hydrodynamic dispersion coefficients (D d ), were determined using an ADE equation. From the experimentally determined values of R, bulk density and porosity, the distribution coefficients (K d ) of the UO 2 2+ species have been calculated for the respective processes. The extent of U sorption in sands, as well as the proportion of desorbed and extracted U from these sands, was also calculated. (author)

  20. Detection and Extraction of Roads from High Resolution Satellites Images with Dynamic Programming

    Science.gov (United States)

    Benzouai, Siham; Smara, Youcef

    2010-12-01

    The advent of satellite images allows now a regular and a fast digitizing and update of geographic data, especially roads which are very useful for Geographic Information Systems (GIS) applications such as transportation, urban pollution, geomarketing, etc. For this, several studies have been conducted to automate roads extraction in order to minimize the manual processes [4]. In this work, we are interested in roads extraction from satellite imagery with high spatial resolution (at best equal to 10 m). The method is semi automatic and follows a linear approach where road is considered as a linear object. As roads extraction is a pattern recognition problem, it is useful, above all, to characterize roads. After, we realize a pre-processing by applying an Infinite Size Edge Filter -ISEF- and processing method based on dynamic programming concept, in particular, Fishler algorithm designed by F*.

  1. A framework for extracting and representing project knowledge contexts using topic models and dynamic knowledge maps

    Science.gov (United States)

    Xu, Jin; Li, Zheng; Li, Shuliang; Zhang, Yanyan

    2015-07-01

    There is still a lack of effective paradigms and tools for analysing and discovering the contents and relationships of project knowledge contexts in the field of project management. In this paper, a new framework for extracting and representing project knowledge contexts using topic models and dynamic knowledge maps under big data environments is proposed and developed. The conceptual paradigm, theoretical underpinning, extended topic model, and illustration examples of the ontology model for project knowledge maps are presented, with further research work envisaged.

  2. Determination of volatile organic hydrocarbons in water samples by solid-phase dynamic extraction.

    Science.gov (United States)

    Jochmann, Maik A; Yuan, Xue; Schmidt, Torsten C

    2007-03-01

    In the present study a headspace solid-phase dynamic extraction method coupled to gas chromatography-mass spectrometry (HS-SPDE-GC/MS) for the trace determination of volatile halogenated hydrocarbons and benzene from groundwater samples was developed and evaluated. As target compounds, benzene as well as 11 chlorinated and brominated hydrocarbons (vinyl chloride, dichloromethane, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, carbon tetrachloride, chloroform, trichloroethylene, tetrachloroethylene, bromoform) of environmental and toxicological concern were included in this study. The analytes were extracted using a SPDE needle device, coated with a poly(dimethylsiloxane) with 10% embedded activated carbon phase (50-microm film thickness and 56-mm film length) and were analyzed by GC/MS in full-scan mode. Parameters that affect the extraction yield such as extraction and desorption temperature, salting-out, extraction and desorption flow rate, extraction volume and desorption volume, the number of extraction cycles, and the pre-desorption time have been evaluated and optimized. The linearity of the HS-SPDE-GC/MS method was established over several orders of magnitude. Method detection limits (MDLs) for the compounds investigated ranged between 12 ng/L for cis-dichloroethylene and trans-dichloroethylene and 870 ng/L for vinyl chloride. The method was thoroughly validated, and the precision at two concentration levels (0.1 mg/L and a concentration 5 times above the MDL) was between 3.1 and 16% for the analytes investigated. SPDE provides high sensitivity, short sample preparation and extraction times and a high sample throughput because of full automation. Finally, the applicability to real environmental samples is shown exemplarily for various groundwater samples from a former waste-oil recycling facility. Groundwater from the site showed a complex contamination with chlorinated volatile organic compounds and aromatic hydrocarbons.

  3. Determination of volatile organic hydrocarbons in water samples by solid-phase dynamic extraction

    Energy Technology Data Exchange (ETDEWEB)

    Jochmann, Maik A.; Schmidt, Torsten C. [Eberhard-Karls-Universitaet Tuebingen, Center for Applied Geoscience (ZAG), Tuebingen (Germany); Chair of Instrumental Analysis, University Duisburg-Essen, Duisburg (Germany); Yuan, Xue [Eberhard-Karls-Universitaet Tuebingen, Center for Applied Geoscience (ZAG), Tuebingen (Germany)

    2007-03-15

    In the present study a headspace solid-phase dynamic extraction method coupled to gas chromatography-mass spectrometry (HS-SPDE-GC/MS) for the trace determination of volatile halogenated hydrocarbons and benzene from groundwater samples was developed and evaluated. As target compounds, benzene as well as 11 chlorinated and brominated hydrocarbons (vinyl chloride, dichloromethane, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, carbon tetrachloride, chloroform, trichloroethylene, tetrachloroethylene, bromoform) of environmental and toxicological concern were included in this study. The analytes were extracted using a SPDE needle device, coated with a poly(dimethylsiloxane) with 10% embedded activated carbon phase (50-{mu}m film thickness and 56-mm film length) and were analyzed by GC/MS in full-scan mode. Parameters that affect the extraction yield such as extraction and desorption temperature, salting-out, extraction and desorption flow rate, extraction volume and desorption volume, the number of extraction cycles, and the pre-desorption time have been evaluated and optimized. The linearity of the HS-SPDE-GC/MS method was established over several orders of magnitude. Method detection limits (MDLs) for the compounds investigated ranged between 12 ng/L for cis-dichloroethylene and trans-dichloroethylene and 870 ng/L for vinyl chloride. The method was thoroughly validated, and the precision at two concentration levels (0.1 mg/L and a concentration 5 times above the MDL) was between 3.1 and 16% for the analytes investigated. SPDE provides high sensitivity, short sample preparation and extraction times and a high sample throughput because of full automation. Finally, the applicability to real environmental samples is shown exemplarily for various groundwater samples from a former waste-oil recycling facility. Groundwater from the site showed a complex contamination with chlorinated volatile organic compounds and aromatic hydrocarbons. (orig.)

  4. On-Line Impact Load Identification

    Directory of Open Access Journals (Sweden)

    Krzysztof Sekuła

    2013-01-01

    Full Text Available The so-called Adaptive Impact Absorption (AIA is a research area of safety engineering devoted to problems of shock absorption in various unpredictable scenarios of collisions. It makes use of smart technologies (systems equipped with sensors, controllable dissipaters and specialised tools for signal processing. Examples of engineering applications for AIA systems are protective road barriers, automotive bumpers or adaptive landing gears. One of the most challenging problems for AIA systems is on-line identification of impact loads, which is crucial for introducing the optimum real-time strategy of adaptive impact absorption. This paper presents the concept of an impactometer and develops the methodology able to perform real-time impact load identification. Considered dynamic excitation is generated by a mass M1 impacting with initial velocity V0. An analytical formulation of the problem, supported with numerical simulations and experimental verifications is presented. Two identification algorithms based on measured response of the impacted structure are proposed and discussed. Finally, a concept of the AIA device utilizing the idea of impactometer is briefly presented.

  5. An interior needle electropolymerized pyrrole-based coating for headspace solid-phase dynamic extraction

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Habib [Department of Chemistry, Sharif University of Technology, Azadi Av., P.O. Box 11365-9516, Tehran (Iran, Islamic Republic of)], E-mail: bagheri@sharif.edu; Babanezhad, Esmaeil; Khalilian, Faezeh [Department of Chemistry, Sharif University of Technology, Azadi Av., P.O. Box 11365-9516, Tehran (Iran, Islamic Republic of)

    2009-02-23

    A headspace solid-phase dynamic extraction (HS-SPDE) technique was developed by the use of polypyrrole (PPy) sorbent, electropolymerized inside the surface of a needle, as a possible alternative to solid-phase microextraction (SPME). Thermal desorption was subsequently, employed to transfer the extracted analytes into the injection port of a gas chromatography-mass spectrometry (GC-MS). The PPy sorbent including polypyrrole-dodecyl sulfate (PPy-DS) was deposited on the interior surface of a stainless steel needle from the corresponding aqueous electrolyte by applying a constant deposition potential. The homogeneity and the porous surface structure of the coating were examined using the scanning electron microscopy (SEM). The developed method was applied to the trace level extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample. In order to enhance the extraction efficiency and increase the partition coefficient of analytes, the stainless steel needle was cooled at 5 deg. C, while the sample solution was kept at 80 deg. C. Optimization of influential experimental conditions including the voltage of power supply, the time of PPy electrodeposition, the extraction temperature, the ionic strength and the extraction time were also investigated. The detection limits of the method under optimized conditions were in the range of 0.002-0.01 ng mL{sup -1}. The relative standard deviations (R.S.D.) at a concentration level of 0.1 ng mL{sup -1} were obtained between 7.54 and 11.4% (n = 6). The calibration curves of PAHs showed linearity in the range of 0.01-10 ng mL{sup -1}. The proposed method was successfully applied to the extraction of some selected PAHs from real-life water samples and the relative recoveries were higher than 90% for all the analytes.

  6. Structural damage diagnosis based on on-line recursive stochastic subspace identification

    International Nuclear Information System (INIS)

    Loh, Chin-Hsiung; Weng, Jian-Huang; Liu, Yi-Cheng; Lin, Pei-Yang; Huang, Shieh-Kung

    2011-01-01

    This paper presents a recursive stochastic subspace identification (RSSI) technique for on-line and almost real-time structural damage diagnosis using output-only measurements. Through RSSI the time-varying natural frequencies of a system can be identified. To reduce the computation time in conducting LQ decomposition in RSSI, the Givens rotation as well as the matrix operation appending a new data set are derived. The relationship between the size of the Hankel matrix and the data length in each shifting moving window is examined so as to extract the time-varying features of the system without loss of generality and to establish on-line and almost real-time system identification. The result from the RSSI technique can also be applied to structural damage diagnosis. Off-line data-driven stochastic subspace identification was used first to establish the system matrix from the measurements of an undamaged (reference) case. Then the RSSI technique incorporating a Kalman estimator is used to extract the dynamic characteristics of the system through continuous monitoring data. The predicted residual error is defined as a damage feature and through the outlier statistics provides an indicator of damage. Verification of the proposed identification algorithm by using the bridge scouring test data and white noise response data of a reinforced concrete frame structure is conducted

  7. EXTRACT

    DEFF Research Database (Denmark)

    Pafilis, Evangelos; Buttigieg, Pier Luigi; Ferrell, Barbra

    2016-01-01

    The microbial and molecular ecology research communities have made substantial progress on developing standards for annotating samples with environment metadata. However, sample manual annotation is a highly labor intensive process and requires familiarity with the terminologies used. We have the...... and text-mining-assisted curation revealed that EXTRACT speeds up annotation by 15-25% and helps curators to detect terms that would otherwise have been missed.Database URL: https://extract.hcmr.gr/......., organism, tissue and disease terms. The evaluators in the BioCreative V Interactive Annotation Task found the system to be intuitive, useful, well documented and sufficiently accurate to be helpful in spotting relevant text passages and extracting organism and environment terms. Comparison of fully manual...

  8. Robust on-line monitoring of biogas processes; Robusta maettekniker on-line foer optimerad biogasproduktion

    Energy Technology Data Exchange (ETDEWEB)

    Nordberg, Aake; Hansson, Mikael; Kanerot, Mija; Krozer, Anatol; Loefving, Bjoern; Sahlin, Eskil

    2010-03-15

    project showed that pH-adjustment with Na{sub 3}PO{sub 4} can be a way of compensating for the losses of volatile compounds (up to 20% of VS), which occurs when standardized reference methods are used. This is a fundamental problem and requires further research. Monitoring of a laboratory-scale anaerobic digester with NIR showed that a previously developed multivariate model could predict propionate concentrations (R2= 0,92; RMSEP 0,39 g/L) in the interval 0-5 g/L, which is a relevant interval for inhibition (limit ca 3 g/L). A commercial FT-NIR instrument was subsequently installed at the production plant. However, the organic loading was decreased during the evaluation period due to process disturbances, at which the dynamic of the process was not in the range needed for prediction of e.g. propionate. Measurements and evaluation will continue during normal conditions after the completion of this project. Evaluation of a potentiometric sensor for ammonia with potential for on-line application showed low stability and a need for daily calibration, which therefore did not fulfill the requested demand. The project has demonstrated technologies with significant potential for on-line monitoring at production scale facilities, thus improving the knowledge base for making important decisions. Knowledge about on-line implementation has increased, and important insights into the limitations of standardized reference methods and substrate characteristics have been achieved. Instrument suppliers have in general a limited insight in the conditions at a biogas plant, which suggests that this type of WR-financed project is important for development in the area

  9. Microbial dynamics during azo dye degradation in a UASB reactor supplied with yeast extract.

    Science.gov (United States)

    Silva, S Q; Silva, D C; Lanna, M C S; Baeta, B E L; Aquino, S F

    2014-01-01

    The present work aimed to investigate the microbial dynamics during the anaerobic treatment of the azo dye blue HRFL in bench scale upflow anaerobic sludge bed (UASB) reactor operated at ambient temperature. Sludge samples were collected under distinct operational phases, when the reactor were stable (low variation of color removal), to assess the effect of glucose and yeast extract as source of carbon and redox mediators, respectively. Reactors performance was evaluated based on COD (chemical oxygen demand) and color removal. The microbial dynamics were investigated by PCR-DGGE (Polimerase Chain Reaction - Denaturing Gradient of Gel Electrophoresis) technique by comparing the 16S rDNA profiles among samples. The results suggest that the composition of microorganisms changed from the beginning to the end of the reactor operation, probably in response to the presence of azo dye and/or its degradation byproducts. Despite the highest efficiency of color removal was observed in the presence of 500 mg/L of yeast extract (up to 93%), there were no differences regarding the microbial profiles that could indicate a microbial selection by the yeast extract addition. On the other hand Methosarcina barkeri was detected only in the end of operation when the best efficiencies on color removal occurred. Nevertheless the biomass selection observed in the last stages of UASB operation is probably a result of the washout of the sludge in response of accumulation of aromatic amines which led to tolerant and very active biomass that contributed to high efficiencies on color removal.

  10. Robust signal extraction for on-line monitoring data

    NARCIS (Netherlands)

    Davies, P.L.; Fried, R.; Gather, U.

    2004-01-01

    Data from the automatic monitoring of intensive care patients exhibits trends, outliers, and level changes as well as periods of relative constancy. All this is overlaid with a high level of noise and there are dependencies between the different items measured. Current monitoring systems tend to

  11. Analysis of potential dynamic concealed factors in the difficulty of lower third molar extraction.

    Science.gov (United States)

    Singh, P; Ajmera, D-H; Xiao, S-S; Yang, X-Z; Liu, X; Peng, B

    2016-11-01

    The purpose of this study was to identify potential concealed variables associated with the difficulty of lower third molar (M3) extractions. To address the research purpose, we implemented a prospective study and enrolled a sample of subjects presenting for M3 removal. Predictor variables were categorized into Group-I and Group-II, based on predetermined criteria. The primary outcome variable was the difficulty of extraction, measured as extraction time. Appropriate univariate and multivariate statistics were computed using ordinal logistic regression. The sample comprised of 1235 subjects with a mean age of 29.49 +/- 8.92 years in Group-I and 26.20 +/- 11.55 years in Group-II subjects. The mean operating time per M3 extraction was 21.24 +/- 12.80 and 20.24 +/- 12.50 minutes for Group-I and Group-II subjects respectively. Three linear parameters including B-M2 height (distance between imaginary point B on the inferior border of mandibular body, and M2), lingual cortical thickness, bone density and one angular parameter including Rc-Cs angle (angle between ramus curvature and curve of spee), in addition to patient's age, profile type, facial type, cant of occlusal plane, and decreased overbite, were found to be statistically associated ( p < or = 0.05) with extraction difficulty under regression models. In conclusion, our study indicates that the difficulty of lower M3 extractions is possibly governed by morphological and biomechanical factors with substantial influence of myofunctional factors. Preoperative evaluation of dynamic concealed factors may not only help in envisaging the difficulty and planning of surgical approach but might also help in better time management in clinical practice.

  12. Dynamics of a Rydberg hydrogen atom near a metal surface in the electron-extraction scheme

    Energy Technology Data Exchange (ETDEWEB)

    Iñarrea, Manuel [Área de Física Aplicada, Universidad de La Rioja, Logroño (Spain); Lanchares, Víctor [Departamento de Matemáticas y Computación, Universidad de La Rioja, Logroño, La Rioja (Spain); Palacián, Jesús [Departamento de Ingeniería Matemática e Informática, Universidad Pública de Navarra, Pamplona (Spain); Pascual, Ana I. [Departamento de Matemáticas y Computación, Universidad de La Rioja, Logroño, La Rioja (Spain); Salas, J. Pablo, E-mail: josepablo.salas@unirioja.es [Área de Física Aplicada, Universidad de La Rioja, Logroño (Spain); Yanguas, Patricia [Departamento de Ingeniería Matemática e Informática, Universidad Pública de Navarra, Pamplona (Spain)

    2015-01-23

    We study the classical dynamics of a Rydberg hydrogen atom near a metal surface in the presence of a constant electric field in the electron-extraction situation [1], e.g., when the field attracts the electron to the vacuum. From a dynamical point of view, this field configuration provides a dynamics richer than in the usual ion-extraction scheme, because, depending on the values of field and the atom–surface distance, the atom can be ionized only towards the metal surface, only to the vacuum or to the both sides. The evolution of the phase space structure as a function of the atom–surface distance is explored in the bound regime of the atom. In the high energy regime, the ionization mechanism is also investigated. We find that the classical results of this work are in good agreement with the results obtained in the wave-packet propagation study carried out by So et al. [1]. - Highlights: • We study a classical hydrogen atom near a metal surface plus a electric field. • We explore the phase space structure as a function of the field strength. • We find most of the electronic orbits are oriented along the field direction. • We study the ionization of the atom for several atom–surface distances. • This classical study is in good agreement with the quantum results.

  13. Extracting protein dynamics information from overlapped NMR signals using relaxation dispersion difference NMR spectroscopy.

    Science.gov (United States)

    Konuma, Tsuyoshi; Harada, Erisa; Sugase, Kenji

    2015-12-01

    Protein dynamics plays important roles in many biological events, such as ligand binding and enzyme reactions. NMR is mostly used for investigating such protein dynamics in a site-specific manner. Recently, NMR has been actively applied to large proteins and intrinsically disordered proteins, which are attractive research targets. However, signal overlap, which is often observed for such proteins, hampers accurate analysis of NMR data. In this study, we have developed a new methodology called relaxation dispersion difference that can extract conformational exchange parameters from overlapped NMR signals measured using relaxation dispersion spectroscopy. In relaxation dispersion measurements, the signal intensities of fluctuating residues vary according to the Carr-Purcell-Meiboon-Gill pulsing interval, whereas those of non-fluctuating residues are constant. Therefore, subtraction of each relaxation dispersion spectrum from that with the highest signal intensities, measured at the shortest pulsing interval, leaves only the signals of the fluctuating residues. This is the principle of the relaxation dispersion difference method. This new method enabled us to extract exchange parameters from overlapped signals of heme oxygenase-1, which is a relatively large protein. The results indicate that the structural flexibility of a kink in the heme-binding site is important for efficient heme binding. Relaxation dispersion difference requires neither selectively labeled samples nor modification of pulse programs; thus it will have wide applications in protein dynamics analysis.

  14. Extracting protein dynamics information from overlapped NMR signals using relaxation dispersion difference NMR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Konuma, Tsuyoshi [Icahn School of Medicine at Mount Sinai, Department of Structural and Chemical Biology (United States); Harada, Erisa [Suntory Foundation for Life Sciences, Bioorganic Research Institute (Japan); Sugase, Kenji, E-mail: sugase@sunbor.or.jp, E-mail: sugase@moleng.kyoto-u.ac.jp [Kyoto University, Department of Molecular Engineering, Graduate School of Engineering (Japan)

    2015-12-15

    Protein dynamics plays important roles in many biological events, such as ligand binding and enzyme reactions. NMR is mostly used for investigating such protein dynamics in a site-specific manner. Recently, NMR has been actively applied to large proteins and intrinsically disordered proteins, which are attractive research targets. However, signal overlap, which is often observed for such proteins, hampers accurate analysis of NMR data. In this study, we have developed a new methodology called relaxation dispersion difference that can extract conformational exchange parameters from overlapped NMR signals measured using relaxation dispersion spectroscopy. In relaxation dispersion measurements, the signal intensities of fluctuating residues vary according to the Carr-Purcell-Meiboon-Gill pulsing interval, whereas those of non-fluctuating residues are constant. Therefore, subtraction of each relaxation dispersion spectrum from that with the highest signal intensities, measured at the shortest pulsing interval, leaves only the signals of the fluctuating residues. This is the principle of the relaxation dispersion difference method. This new method enabled us to extract exchange parameters from overlapped signals of heme oxygenase-1, which is a relatively large protein. The results indicate that the structural flexibility of a kink in the heme-binding site is important for efficient heme binding. Relaxation dispersion difference requires neither selectively labeled samples nor modification of pulse programs; thus it will have wide applications in protein dynamics analysis.

  15. Molecular dynamics simulation of cyclodextrin aggregation and extraction of Anthracene from non-aqueous liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xinzhe [Shenzhen Key Laboratory for Coastal Ocean Dynamic and Environment, Division of Ocean Science and Technology, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); School of Environment, Tsinghua University, Beijing 100084 (China); Wu, Guozhong [Shenzhen Key Laboratory for Coastal Ocean Dynamic and Environment, Division of Ocean Science and Technology, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China); Chen, Daoyi, E-mail: chen.daoyi@sz.tsinghua.edu.cn [Shenzhen Key Laboratory for Coastal Ocean Dynamic and Environment, Division of Ocean Science and Technology, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055 (China)

    2016-12-15

    Cyclodextrin (CD) extraction is widely used for the remediation of polycyclic aromatic hydrocarbons (PAH) pollution, but it remains unclear about the influence of CD aggregation on the PAH transport from non-aqueous liquid phase to water. The atomistic adsorption and complexation of PAHs (32 anthracenes) by CD aggregates (48 β-cyclodextrins) were studied by molecular dynamics simulations at hundreds of nanoseconds time scale. Results indicated that high temperature promoted the βCD aggregation in bulk oil, which was not found in bulk water. Nevertheless, the fractions of anthracenes entrapped inside the βCDs cavity in both scenarios were significantly increased when temperature increased from 298 to 328 K. Free energy calculation for the sub-steps of CD extraction demonstrated that the anthracenes could be extracted when the βCDs arrived at the water-oil interface or after the βCDs entered the bulk oil. The former was kinetic-controlled while the latter was thermodynamic-limited process. Results also highlighted the formation of porous structures by CD aggregates in water, which was able to sequestrate PAH clusters with the size obviously larger than the cavity diameter of individual CD. This provided an opportunity for the extraction of recalcitrant PAHs with molecular size larger than anthracenes by cyclodextrins.

  16. Quantify Water Extraction by TBP/Dodecane via Molecular Dynamics Simulations

    International Nuclear Information System (INIS)

    Khomami, Bamin; Cui, Shengting; De Almeida, Valmor F.

    2013-01-01

    The purpose of this project is to quantify the interfacial transport of water into the most prevalent nuclear reprocessing solvent extractant mixture, namely tri-butyl- phosphate (TBP) and dodecane, via massively parallel molecular dynamics simulations on the most powerful machines available for open research. Specifically, we will accomplish this objective by evolving the water/TBP/dodecane system up to 1 ms elapsed time, and validate the simulation results by direct comparison with experimentally measured water solubility in the organic phase. The significance of this effort is to demonstrate for the first time that the combination of emerging simulation tools and state-of-the-art supercomputers can provide quantitative information on par to experimental measurements for solvent extraction systems of relevance to the nuclear fuel cycle. Results: Initially, the isolated single component, and single phase systems were studied followed by the two-phase, multicomponent counterpart. Specifically, the systems we studied were: pure TBP; pure n-dodecane; TBP/n-dodecane mixture; and the complete extraction system: water-TBP/n-dodecane two phase system to gain deep insight into the water extraction process. We have completely achieved our goal of simulating the molecular extraction of water molecules into the TBP/n-dodecane mixture up to the saturation point, and obtained favorable comparison with experimental data. Many insights into fundamental molecular level processes and physics were obtained from the process. Most importantly, we found that the dipole moment of the extracting agent is crucially important in affecting the interface roughness and the extraction rate of water molecules into the organic phase. In addition, we have identified shortcomings in the existing OPLS-AA force field potential for long-chain alkanes. The significance of this force field is that it is supposed to be optimized for molecular liquid simulations. We found that it failed for dodecane and

  17. The Bochum on-line data acquisition system

    International Nuclear Information System (INIS)

    Paul, H.J.; Freiesleben, H.

    1986-01-01

    We describe an on-line data acquisition system based on a PDP 11 computer with CAMAC hardware. The software fully exploits the real-time features of the RSX-11M operating system. The basic characteristics of the program package, mainly written in FORTRAN 77, are: multitasking, shared common blocks, dynamical access to CAMAC hardware and data, and command orientated user interface. The system is particularly tailored for data acquisition in list mode of up to 64 parameters. (orig.)

  18. Shawnee Mission's On-Line Cataloging System

    Directory of Open Access Journals (Sweden)

    Ellen Wasby Miller

    1971-03-01

    Full Text Available An on-line cataloging pilot project for two elementary schools is discussed. The system components are 2740 terminals, upper-lower-case input, IBM's FASTER generalized software package, and usual cards/labels output. Reasons for choosing FASTER, software and hardware features, operating procedures, system performance and costs are detailed. Future expansion to cataloging 100,000 annual K-12 acquisitions, on-line circulation, retrospective conversion, and union book catalogs is set forth.

  19. INIS retrieval service, towards on-line

    International Nuclear Information System (INIS)

    Ebinuma, Yukio; Komatsubara, Yasutoshi

    1983-01-01

    Japan Atomic Energy Research Institute executes the retrieval service of INIS atomic energy information by batch system in cooperation with Genshiryoku Kozaikai. This service is very popular to the users in whole Japan, but the demand of on-line service has increased recently. Therefore, it was decided to begin the INIS on-line service from January, 1984, through the on-line information retrieval system of the Japan Information Center of Science and Technology. It is expected that when the operation will be started, the utilization of INIS atomic energy information in Japan will drastically increase. Also Japan Atomic Energy Research Institute has carried out the retrieval service by on-line system for those in the institute besides the batch system, accordingly, at this opportunity, the state of utilization of both systems and their distinction to use effectively, and the operation and the method of utilization of the on-line information retrieval system of JICST are explained. In the on-line system, the users are accessible to the data base themselves, and immediate information retrieval is possible, while in the batch system, the related information can be retrieved without fail, and the troublesome operation of equipment is not necessary. (Kako, I.)

  20. In situ analysis of dynamic laminar flow extraction using surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Wang, Fei; Wang, Hua-Lin; Qiu, Yang; Chang, Yu-Long; Long, Yi-Tao

    2015-12-01

    In this study, we performed micro-scale dynamic laminar flow extraction and site-specific in situ chloride concentration measurements. Surface-enhanced Raman spectroscopy was utilized to investigate the diffusion process of chloride ions from an oil phase to a water phase under laminar flow. In contrast to common logic, we used SERS intensity gradients of Rhodamine 6G to quantitatively calculate the concentration of chloride ions at specific positions on a microfluidic chip. By varying the fluid flow rates, we achieved different extraction times and therefore different chloride concentrations at specific positions along the microchannel. SERS spectra from the water phase were recorded at these different positions, and the spatial distribution of the SERS signals was used to map the degree of nanoparticle aggregation. The concentration of chloride ions in the channel could therefore be obtained. We conclude that this method can be used to explore the extraction behaviour and efficiency of some ions or molecules that enhance the SERS intensity in water or oil by inducing nanoparticle aggregation.

  1. Automated headspace solid-phase dynamic extraction to analyse the volatile fraction of food matrices.

    Science.gov (United States)

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara

    2004-01-23

    High concentration capacity headspace techniques (headspace solid-phase microextraction (HS-SPME) and headspace sorptive extraction (HSSE)) are a bridge between static and dynamic headspace, since they give high concentration factors as does dynamic headspace (D-HS), and are as easy to apply and as reproducible as static headspace (S-HS). In 2000, Chromtech (Idstein, Germany) introduced an inside-needle technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as "the magic needle". In SPDE, analytes are concentrated on a 50 microm film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5 cm) of a 2.5 ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace of the sample under investigation is sucked up an appropriate number of times with the gas tight syringe and an analyte amount suitable for a reliable GC or GC-MS analysis accumulates in the polymer coating the needle wall. This article describes the preliminary results of both a study on the optimisation of sampling parameters conditioning HS-SPDE recovery, through the analysis of a standard mixture of highly volatile compounds (beta-pinene, isoamyl acetate and linalool) and of the HS-SPDE-GC-MS analyses of aromatic plants and food matrices. This study shows that HS-SPDE is a successful technique for HS-sampling with high concentration capability, good repeatability and intermediate precision, also when it is compared to HS-SPME.

  2. On line surveillance of large systems: applications to nuclear and chemical plant

    International Nuclear Information System (INIS)

    Zwingelstein, G.

    1978-01-01

    An on line surveillance method for large scale and distributed parameter systems is achieved by comparing in real time the internal physical parameter values to the reference values. It is shown that the following steps are necessary: modeling, model validation using dynamic testing and on line estimation of parameters. For large scale systems where only few outputs are measurable, an estimation algorithm was developed, selecting the measurable output giving the minimum variance of the physical parameters. This estimation scheme uses a quasilinearization technique associated to the sensitivity equation and the recursive least squares techniques. For large scale systems of order greater than 100, two versions of the estimation scheme are proposed to decrease the computation time. An application to a nuclear reactor core (state variable model of order 29) is proposed and used real data. For distributed systems the estimation scheme was developed with either measurements at fixed time or at fixed space. The estimation algorithm selects the set of measurements that gives the minimum variance of the estimates. An application to a liquid-liquid extraction column, modelized by a set of four coupled partial differential equations, demonstrates the efficiency of the method

  3. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, M.

    2005-09-01

    On-Line Monitoring evaluates instrument channel performance by assessing its consistency with other plant indications. Elimination or reduction of unnecessary field calibrations can reduce associated labour costs, reduce personnel radiation exposure, and reduce the potential for calibration errors. On-line calibration monitoring is an important technique to implement a state-based maintenance approach and reduce unnecessary field calibrations. In this report we will look at how the concept is currently applied in the industry and what the arising needs are as it becomes more commonplace. We will also look at the PEANO System, a tool developed by the Halden Project to perform signal validation and on-line calibration monitoring. Some issues will be identified that are being addressed in the further development of these tools to better serve the future needs of the industry in this area. An outline for how to improve these points and which aspects should be taken into account is described in detail. (Author)

  4. Development of "ultrasound-assisted dynamic extraction" and its combination with CCC and CPC for simultaneous extraction and isolation of phytochemicals.

    Science.gov (United States)

    Zhang, Yuchi; Liu, Chunming; Li, Jing; Qi, Yanjuan; Li, Yuchun; Li, Sainan

    2015-09-01

    A new method for the extraction of medicinal herbs termed ultrasonic-assisted dynamic extraction (UADE) was designed and evaluated. This technique was coupled with counter-current chromatography (CCC) and centrifugal partition chromatography (CPC) and then applied to the continuous extraction and online isolation of chemical constituents from Paeonia lactiflora Pall (white peony) roots. The mechanical parameters, including the pitch and diameter of the shaft, were optimized by means of mathematical modeling. Furthermore, the configuration and mechanism of online UADE coupled with CCC and CPC were elaborated. The stationary phases of the two-phase solvent systems from CCC and CPC were utilized as the UADE solution. The extraction solution was pumped into the sample loop and then introduced into the CCC column; the target compounds were eluted with the lower aqueous phase of the two-phase solvent system. During the CCC separation, the extraction solution was continuously fed in the sample loop by turning the ten-port valve; the extraction solution was then pumped into the CPC column and eluted by the mobile phase of the two-phase solvent system mentioned above. When the first cycle of the UADE/CCC/CPC was completed, the second cycle experiment could be carried out, and so on. Four target compounds (albiflorin, benzoylpaeoniflorin, paeoniflorin, and galloylpaeoniflorin) with purities above 94.96% were successfully extracted and isolated online using the two-phase solvent system comprising ethyl acetate-n-butanol-ethanol-water (1:3.5:2:4.5, v/v/v/v). Compared with conventional extraction methods, the instrumental setup of the present method offers the advantages of automation and systematic extraction and isolation of natural products. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  5. Rapid Solid-Liquid Dynamic Extraction (RSLDE): a New Rapid and Greener Method for Extracting Two Steviol Glycosides (Stevioside and Rebaudioside A) from Stevia Leaves.

    Science.gov (United States)

    Gallo, Monica; Vitulano, Manuela; Andolfi, Anna; DellaGreca, Marina; Conte, Esterina; Ciaravolo, Martina; Naviglio, Daniele

    2017-06-01

    Stevioside and rebaudioside A are the main diterpene glycosides present in the leaves of the Stevia rebaudiana plant, which is used in the production of foods and low-calorie beverages. The difficulties associated with their extraction and purification are currently a problem for the food processing industries. The objective of this study was to develop an effective and economically viable method to obtain a high-quality product while trying to overcome the disadvantages derived from the conventional transformation processes. For this reason, extractions were carried out using a conventional maceration (CM) and a cyclically pressurized extraction known as rapid solid-liquid dynamic extraction (RSLDE) by the Naviglio extractor (NE). After only 20 min of extraction using the NE, a quantity of rebaudioside A and stevioside equal to 1197.8 and 413.6 mg/L was obtained, respectively, while for the CM, the optimum time was 90 min. From the results, it can be stated that the extraction process by NE and its subsequent purification developed in this study is a simple, economical, environmentally friendly method for producing steviol glycosides. Therefore, this method constitutes a valid alternative to conventional extraction by reducing the extraction time and the consumption of toxic solvents and favouring the use of the extracted metabolites as food additives and/or nutraceuticals. As an added value and of local interest, the experiment was carried out on stevia leaves from the Benevento area (Italy), where a high content of rebaudioside A was observed, which exhibits a sweet taste compared to stevioside, which has a significant bitter aftertaste.

  6. On-line signal trend identification

    International Nuclear Information System (INIS)

    Tambouratzis, T.; Antonopoulos-Domis, M.

    2004-01-01

    An artificial neural network, based on the self-organizing map, is proposed for on-line signal trend identification. Trends are categorized at each incoming signal as steady-state, increasing and decreasing, while they are further classified according to characteristics such signal shape and rate of change. Tests with model-generated signals illustrate the ability of the self-organizing map to accurately and reliably perform on-line trend identification in terms of both detection and classification. The proposed methodology has been found robust to the presence of white noise

  7. On-line atomic data access

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, D.R. [Oak Ridge National Lab., TN (United States); Nash, J.K. [Lawrence Livermore National Lab., CA (United States)

    1996-04-01

    The need for atomic data is one which continues to expand in a wide variety of applications including fusion energy, astrophysics, laser- produced plasma research, and plasma processing. Modern computer database and communications technology nables this data to be placed on-line and obtained by users of the Internet. Presented here is a summary of the observations and conclusions regarding such on-line atomic data access derived from a forum held at the Tenth APS Topical Conference on Atomic Processes in Plasmas.

  8. The development of an on-line gold analyser

    International Nuclear Information System (INIS)

    Robert, R.V.D.; Ormrod, G.T.W.

    1982-01-01

    An on-line analyser to monitor the gold in solutions from the carbon-in-pulp process is described. The automatic system is based on the delivery of filtered samples of the solutions to a distribution valve for measurement by flameless atomic-absorption spectrophotometry. The samples is introduced by the aerosol-deposition method. Operation of the analyser on a pilot plant and on a full-scale carbon-in-pulp plant has shown that the system is economically feasible and capable of providing a continuous indication of the efficiency of the extraction process

  9. Optimal Elbow Angle for Extracting sEMG Signals During Fatiguing Dynamic Contraction

    Directory of Open Access Journals (Sweden)

    Mohamed R. Al-Mulla

    2015-09-01

    Full Text Available Surface electromyographic (sEMG activity of the biceps muscle was recorded from 13 subjects. Data was recorded while subjects performed dynamic contraction until fatigue and the signals were segmented into two parts (Non-Fatigue and Fatigue. An evolutionary algorithm was used to determine the elbow angles that best separate (using Davies-Bouldin Index, DBI both Non-Fatigue and Fatigue segments of the sEMG signal. Establishing the optimal elbow angle for feature extraction used in the evolutionary process was based on 70% of the conducted sEMG trials. After completing 26 independent evolution runs, the best run containing the optimal elbow angles for separation (Non-Fatigue and Fatigue was selected and then tested on the remaining 30% of the data to measure the classification performance. Testing the performance of the optimal angle was undertaken on nine features extracted from each of the two classes (Non-Fatigue and Fatigue to quantify the performance. Results showed that the optimal elbow angles can be used for fatigue classification, showing 87.90% highest correct classification for one of the features and on average of all eight features (including worst performing features giving 78.45%.

  10. Evaluation of methods for extraction of the volitional EMG in dynamic hybrid muscle activation

    Directory of Open Access Journals (Sweden)

    Mizrahi Joseph

    2006-11-01

    Full Text Available Abstract Background Hybrid muscle activation is a modality used for muscle force enhancement, in which muscle contraction is generated from two different excitation sources: volitional and external, by means of electrical stimulation (ES. Under hybrid activation, the overall EMG signal is the combination of the volitional and ES-induced components. In this study, we developed a computational scheme to extract the volitional EMG envelope from the overall dynamic EMG signal, to serve as an input signal for control purposes, and for evaluation of muscle forces. Methods A "synthetic" database was created from in-vivo experiments on the Tibialis Anterior of the right foot to emulate hybrid EMG signals, including the volitional and induced components. The database was used to evaluate the results obtained from six signal processing schemes, including seven different modules for filtration, rectification and ES component removal. The schemes differed from each other by their module combinations, as follows: blocking window only, comb filter only, blocking window and comb filter, blocking window and peak envelope, comb filter and peak envelope and, finally, blocking window, comb filter and peak envelope. Results and conclusion The results showed that the scheme including all the modules led to an excellent approximation of the volitional EMG envelope, as extracted from the hybrid signal, and underlined the importance of the artifact blocking window module in the process. The results of this work have direct implications on the development of hybrid muscle activation rehabilitation systems for the enhancement of weakened muscles.

  11. Dynamic aperture ampersand extraction studies for the SSC High-Energy Booster

    International Nuclear Information System (INIS)

    Chao, A.W.; Dutt, S.K.; Johnson, D.E.; Sen, T.; Yan, Y.

    1990-09-01

    The final booster in the injector chain for the Superconducting Super Collider is a machine approximately twice the size of the Tevatron. Its design includes approximately 450, 15+ m superconducting dipoles. The original designs specified dipoles with a 7 cm coil-winding diameter and an inner horizontal beam-pipe aperture of 55 mm. This dipole design was chosen in order to provide an adequately large good-field aperture for both the beam injection process and for the slow-extraction of high-energy test beams. With the recent decision to increase the Collider dipole coil-winding diameter to 5 cm, the question of the needed HEB aperture was raised. An argument for dipole commonality between the HEB and Collider was developed, and a preliminary examination of a 5 cm HEB dipole was undertaken. This paper reports the results of a detailed study of the injection dynamic aperture for magnet errors corresponding to both a 5 cm and 7 cm dipole. Also studied and reported are preliminary results of the resonant-extraction process for the two magnet designs in question. These studies are in the form of multiparticle computer simulations. The results of the studies indicate that the 7 cm dipole design is consistent with the desired performance requirements for the HEB, while the 5 cm dipole design is marginal. We have not studied intermediate aperture values. 8 refs., 11 figs

  12. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, Mario; Gran, Frauke Schmitt; Thunem, Harald P-J.

    2004-04-01

    On-Line Monitoring (OLM) of a channel's calibration state evaluates instrument channel performance by assessing its consistency with other plant indications. Industry and experience at several plants has shown this overall approach to be very effective in identifying instrument channels that are exhibiting degrading or inconsistent performance characteristics. The Halden Reactor Project has developed the signal validation system PEANO, which can be used to assist with the tasks of OLM. To further enhance the PEANO System for use as a calibration reduction tool, the following two additional modules have been developed; HRP Prox, which performs pre-processing and statistical analysis of signal data, Batch Monitoring Module (BMM), which is an off-line batch monitoring and reporting suite. The purpose and functionality of the HRP Prox and BMM modules are discussed in this report, as well as the improvements made to the PEANO Server to support these new modules. The Halden Reactor Project has established a Halden On-Line Monitoring User Group (HOLMUG), devoted to the discussion and implementation of on-line monitoring techniques in power plants. It is formed by utilities, vendors, regulatory bodies and research institutes that meet regularly to discuss implementation aspects of on-line monitoring, technical specification changes, cost-benefit analysis and regulatory issues. (Author)

  13. SPIRES I: on-line search guide

    International Nuclear Information System (INIS)

    Addis, L.

    1975-06-01

    SPIRES I is the first generation of the on-line Stanford Public Information Retrieval System. Designed as a prototype system, SPIRES I was later moved to the SLAC computing facility where it has been routinely available to SLAC users in the field of high-energy physics. The scope and use of the SPIRES I system are described in this manual

  14. HOPI: on-line injection optimization program

    International Nuclear Information System (INIS)

    LeMaire, J.L.

    1977-01-01

    A method of matching the beam from the 200 MeV linac to the AGS without the necessity of making emittance measurements is presented. An on-line computer program written on the PDP10 computer performs the matching by modifying independently the horizontal and vertical emittance. Experimental results show success with this method, which can be applied to any matching section

  15. Optimal dynamic water allocation: Irrigation extractions and environmental tradeoffs in the Murray River, Australia

    Science.gov (United States)

    Grafton, R. Quentin; Chu, Hoang Long; Stewardson, Michael; Kompas, Tom

    2011-12-01

    A key challenge in managing semiarid basins, such as in the Murray-Darling in Australia, is to balance the trade-offs between the net benefits of allocating water for irrigated agriculture, and other uses, versus the costs of reduced surface flows for the environment. Typically, water planners do not have the tools to optimally and dynamically allocate water among competing uses. We address this problem by developing a general stochastic, dynamic programming model with four state variables (the drought status, the current weather, weather correlation, and current storage) and two controls (environmental release and irrigation allocation) to optimally allocate water between extractions and in situ uses. The model is calibrated to Australia's Murray River that generates: (1) a robust qualitative result that "pulse" or artificial flood events are an optimal way to deliver environmental flows over and above conveyance of base flows; (2) from 2001 to 2009 a water reallocation that would have given less to irrigated agriculture and more to environmental flows would have generated between half a billion and over 3 billion U.S. dollars in overall economic benefits; and (3) water markets increase optimal environmental releases by reducing the losses associated with reduced water diversions.

  16. Oleuropein-Enriched Olive Leaf Extract Affects Calcium Dynamics and Impairs Viability of Malignant Mesothelioma Cells

    Directory of Open Access Journals (Sweden)

    Carla Marchetti

    2015-01-01

    Full Text Available Malignant mesothelioma is a poor prognosis cancer in urgent need of alternative therapies. Oleuropein, the major phenolic of olive tree (Olea europaea L., is believed to have therapeutic potentials for various diseases, including tumors. We obtained an oleuropein-enriched fraction, consisting of 60% w/w oleuropein, from olive leaves, and assessed its effects on intracellular Ca2+ and cell viability in mesothelioma cells. Effects of the oleuropein-enriched fraction on Ca2+ dynamics and cell viability were studied in the REN mesothelioma cell line, using fura-2 microspectrofluorimetry and MTT assay, respectively. Fura-2-loaded cells, transiently exposed to the oleuropein-enriched fraction, showed dose-dependent transient elevations of cytosolic Ca2+ concentration (Ca2+i. Application of standard oleuropein and hydroxytyrosol, and of the inhibitor of low-voltage T-type Ca2+ channels NNC-55-0396, suggested that the effect is mainly due to oleuropein acting through its hydroxytyrosol moiety on T-type Ca2+ channels. The oleuropein-enriched fraction and standard oleuropein displayed a significant antiproliferative effect, as measured on REN cells by MTT cell viability assay, with IC50 of 22 μg/mL oleuropein. Data suggest that our oleuropein-enriched fraction from olive leaf extract could have pharmacological application in malignant mesothelioma anticancer therapy, possibly by targeting T-type Ca2+ channels and thereby dysregulating intracellular Ca2+ dynamics.

  17. Elucidation of the structure of organic solutions in solvent extraction by combining molecular dynamics and X-ray scattering

    International Nuclear Information System (INIS)

    Ferru, G.; Gomes Rodrigues, D.; Berthon, L.; Guilbaud, P.; Diat, O.; Bauduin, P.

    2014-01-01

    Knowledge of the supramolecular structure of the organic phase containing amphiphilic ligand molecules is mandatory for full comprehension of ionic separation during solvent extraction. Existing structural models are based on simple geometric aggregates, but no consensus exists on the interaction potentials. Herein, we show that molecular dynamics crossed with scattering techniques offers key insight into the complex fluid involving weak interactions without any long range ordering. Two systems containing mono- or diamide extractants in heptane and contacted with an aqueous phase were selected as examples to demonstrate the advantages of coupling the two approaches for furthering fundamental studies on solvent extraction. (authors)

  18. Extracting aerobic system dynamics during unsupervised activities of daily living using wearable sensor machine learning models.

    Science.gov (United States)

    Beltrame, Thomas; Amelard, Robert; Wong, Alexander; Hughson, Richard L

    2018-02-01

    Physical activity levels are related through algorithms to the energetic demand, with no information regarding the integrity of the multiple physiological systems involved in the energetic supply. Longitudinal analysis of the oxygen uptake (V̇o 2 ) by wearable sensors in realistic settings might permit development of a practical tool for the study of the longitudinal aerobic system dynamics (i.e., V̇o 2 kinetics). This study evaluated aerobic system dynamics based on predicted V̇o 2 data obtained from wearable sensors during unsupervised activities of daily living (μADL). Thirteen healthy men performed a laboratory-controlled moderate exercise protocol and were monitored for ≈6 h/day for 4 days (μADL data). Variables derived from hip accelerometer (ACC HIP ), heart rate monitor, and respiratory bands during μADL were extracted and processed by a validated random forest regression model to predict V̇o 2 . The aerobic system analysis was based on the frequency-domain analysis of ACC HIP and predicted V̇o 2 data obtained during μADL. Optimal samples for frequency domain analysis (constrained to ≤0.01 Hz) were selected when ACC HIP was higher than 0.05 g at a given frequency (i.e., participants were active). The temporal characteristics of predicted V̇o 2 data during μADL correlated with the temporal characteristics of measured V̇o 2 data during laboratory-controlled protocol ([Formula: see text] = 0.82, P system dynamics can be investigated during unsupervised activities of daily living by wearable sensors. Although speculative, these algorithms have the potential to be incorporated into wearable systems for early detection of changes in health status in realistic environments by detecting changes in aerobic response dynamics. NEW & NOTEWORTHY The early detection of subclinical aerobic system impairments might be indicative of impaired physiological reserves that impact the capacity for physical activity. This study is the first to use wearable

  19. Dynamic fabric phase sorptive extraction for a group of pharmaceuticals and personal care products from environmental waters.

    Science.gov (United States)

    Lakade, Sameer S; Borrull, Francesc; Furton, Kenneth G; Kabir, Abuzar; Marcé, Rosa Maria; Fontanals, Núria

    2016-07-22

    This paper describes for the first time the use of a new extraction technique, based on fabric phase sorptive extraction (FPSE). This new mode proposes the extraction of the analytes in dynamic mode in order to reduce the extraction time. Dynamic fabric phase sorptive extraction (DFPSE) followed by liquid chromatography-tandem mass spectrometry was evaluated for the extraction of a group of pharmaceuticals and personal care products (PPCPs) from environmental water samples. Different parameters affecting the extraction were optimized and best conditions were achieved when 50mL of sample at pH 3 was passed through 3 disks and analytes retained were eluted with 10mL of ethyl acetate. The recoveries were higher than 60% for most of compounds with the exception of the most polar ones (between 8% and 38%). The analytical method was validated with environmental samples such as river water and effluent and influent wastewater, and good performance was obtained. The analysis of samples revealed the presence of some PPCPs at low ngL(-1) concentrations. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Educational On-Line Gaming Propensity

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana; Kirchner, Kathrin

    2014-01-01

    Educational on-line games are promising for new generations of students who are grown up digital. Th e new generations of students are technology savvy and spend lots of time on the web and on social networks. Based on an exploratory study, this article investigates the factors that infl uence...... students’ willingness to participate in serious games for teaching/learning. Th is study investigates the relationship between students’ behavior on Facebook, Facebook games, and their attitude toward educational on-line games. Th e results of the study reveal that the early adopters of educational games...... are likely to be students, who are young, have only a few Facebook connections, who currently play Facebook game(s). Furthermore, the study emphasizes that there may be differences between students coming from various countries....

  1. Trends in on-line data processing

    International Nuclear Information System (INIS)

    Masetti, M.

    1981-01-01

    The developement of integrated circuits has been characterized by an exponential growth of gates on a single chip that will still continue in the coming years. In parallel the price per bit is dropping down with more or less the same law. As a consequence of this a few statements can be made: The present 16-bit minicomputer in a small configuration is going to be substituted by a 16-bit microcomputer, and the 16-bit microcomputer in a powerful configuration by a 32-bit midi having also a virtual memory facility. Fully programmable or microcoded powerful devices like the LASS hardware processor or MICE, will allow an efficient on-line filter. Higher computing speed can be achieved by a multiprocessor configuration which can be insensitive to hardware failures. Therefore we are moving towards an integrated on-line computing system with much higher computing power than now and the present distinction between on-line and off-line will no longer be so sharp. As more processing can be performed on-line, fast high quality feed-back can be provided for the experiment. In the years to come the trend towards more processing power, at a lower price, and assembled in the same hardware volume will continue for at least five years; at the same time the future large high-energy physics experiments at LEP will be carried out within a wide international collaboration. In this environment methods must be found for a large fraction of the work to be distributed amongst the collaborators. To accomplish this aim it is necessary to introduce common standard practices concerning both hardware and software, in such a way that the seperate parts, developed by the collaborators, will be plug-compatible. (orig.)

  2. New Trends in on-line Marketing

    OpenAIRE

    Palkovič, Lukáš

    2011-01-01

    This bachelor thesis deals with new trend of internet marketing, it focuses especially on viral marketing. The theoretical part charasterizes the process of viral campaigns, furthermore deals with the components and aspects of on-line environment. Another separated chapter presents social networks, their place in viral marketing and at last but not least the viral video making process. The practical part contains different analyses of specific viral campaigns. The next and equally the last pa...

  3. On-Line Maintenance Methodology Development

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Won; Kim, Jae Ho; Jae, Moo Sung [Hanyang University, Seoul (Korea, Republic of)

    2012-05-15

    Most of domestic maintenance activities for nuclear power plants are performed while overhaul. Therefore, On-Line Maintenance (OLM) is one of the proper risks informed application techniques for diffusing maintenance burden during overhaul with safety of the plant is secured. The NUMARC 93-01 (Rev.3) presents the OLM state of the art and it provides methodology. This study adopts NUMARC 93-01 (Rev.3) and present OLM. The reference component is Emergency Diesel Generator (EDG) of Ulchin 3, 4

  4. Myocardial oxygen extraction fraction measured using bolus inhalation of 15O-oxygen gas and dynamic PET

    NARCIS (Netherlands)

    Lubberink, Mark; Wong, YY; Raijmakers, P. G.; Huisman, Marc C.; Schuit, Robert C.; Luurtsema, Geert; Boellaard, Ronald; Knaapen, P; Vonk-Noordegraaf, Anton; Lammertsma, Adriaan A.

    Abstract The aim of this study was to determine the accuracy of oxygen extraction fraction (OEF) measurements using a dynamic scan protocol after bolus inhalation of 15O2. The method of analysis was optimized by investigating potential reuse of myocardial blood flow (MBF), perfusable tissue

  5. A Review of In-Office Dynamic Image Navigation for Extraction of Complex Mandibular Third Molars.

    Science.gov (United States)

    Emery, Robert W; Korj, Oxana; Agarwal, Ravi

    2017-08-01

    We performed a retrospective review of in-office removal of complex mandibular third molars with a dynamic image navigation system (DINS). A retrospective review was conducted of cases completed from 2010 to 2014 by a single oral and maxillofacial surgeon. The average age of the patients was 47 years (range, 27 to 72 years). Extraction complexity was classified with Juodzbalys and Daugela's classification system. The included study cases had complexity scores of 9 or greater. Each patient received custom intraoral splints to secure the tracking array and underwent cone beam computed tomography image acquisition. All surgical procedures were performed with a precalibrated tracking straight handpiece under dynamic navigation. All 25 cases were treated successfully with the use of the DINS. Twelve of these cases were associated with pathologic lesions. Three patients were noted to have inferior alveolar nerve paresthesia. One patient sustained a pathologic fracture at week 2. Postoperative infections were noted in 7 cases, 2 of which had a pre-existing infection. One patient reported temporary limitation of mouth opening. A coronectomy was performed in 1 case. We present results using a new technology, the DINS, for removal of complex mandibular third molars. Potential advantages are 1) improved visualization and localization of anatomic structures such as the inferior alveolar nerve, lingual cortical plate, and adjacent roots; 2) improved control during osteotomy; 3) decreased surgical access requirements and reduction in overall bone removal; 4) ability to perform complex procedures successfully in an in-office setting; 5) decreased surgical time resulting from improved visualization; and 6) potential use as a teaching tool. Possible limitations of the use of an in-office DINS include increased cost, increased time attributed to presurgical planning, initial learning curve, and optical array interference by the surgeon or assistants during surgery. Copyright

  6. Computational Fluid Dynamics Based Extraction of Heat Transfer Coefficient in Cryogenic Propellant Tanks

    Science.gov (United States)

    Yang, H. Q.; West, Jeff

    2015-01-01

    Current reduced-order thermal model for cryogenic propellant tanks is based on correlations built for flat plates collected in the 1950's. The use of these correlations suffers from: inaccurate geometry representation; inaccurate gravity orientation; ambiguous length scale; and lack of detailed validation. The work presented under this task uses the first-principles based Computational Fluid Dynamics (CFD) technique to compute heat transfer from tank wall to the cryogenic fluids, and extracts and correlates the equivalent heat transfer coefficient to support reduced-order thermal model. The CFD tool was first validated against available experimental data and commonly used correlations for natural convection along a vertically heated wall. Good agreements between the present prediction and experimental data have been found for flows in laminar as well turbulent regimes. The convective heat transfer between tank wall and cryogenic propellant, and that between tank wall and ullage gas were then simulated. The results showed that commonly used heat transfer correlations for either vertical or horizontal plate over predict heat transfer rate for the cryogenic tank, in some cases by as much as one order of magnitude. A characteristic length scale has been defined that can correlate all heat transfer coefficients for different fill levels into a single curve. This curve can be used for the reduced-order heat transfer model analysis.

  7. DNA purification using dynamic solid-phase extraction on a rotationally-driven polyethylene-terephthalate microdevice

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, K.R. [Department of Chemistry, University of Virginia, Charlottesville, VA 22904 (United States); Borba, J.C. [Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos-SP (Brazil); Meija, M. [Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Mills, D.L. [TeGrex Technologies, Sperryville, VA 22740 (United States); Haverstick, D.M. [Department of Pathology, University of Virginia, Charlottesville, VA 22904 (United States); Olson, K.E.; Aranda, R. [Office of the Chief Scientist, Defense Forensic Science Center, N 31st Street, Atlanta, GA 30297 (United States); Garner, G.T. [Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Carrilho, E. [Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos-SP (Brazil); Landers, J.P., E-mail: landers@virginia.edu [Department of Chemistry, University of Virginia, Charlottesville, VA 22904 (United States); Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Department of Pathology, University of Virginia, Charlottesville, VA 22904 (United States)

    2016-09-21

    We report the development of a disposable polyester toner centrifugal device for semi-automated, dynamic solid phase DNA extraction (dSPE) from whole blood samples. The integration of a novel adhesive and hydrophobic valving with a simple and low cost microfabrication method allowed for sequential addition of reagents without the need for external equipment for fluid flow control. The spin-dSPE method yielded an average extraction efficiency of ∼45% from 0.6 μL of whole blood. The device performed single sample extractions or accommodate up to four samples for simultaneous DNA extraction, with PCR-readiness DNA confirmed by effective amplification of a β-globin gene. The purity of the DNA was challenged by a multiplex amplification with 16 targeted amplification sites. Successful multiplexed amplification could routinely be obtained using the purified DNA collected post an on-chip extraction, with the results comparable to those obtained with commercial DNA extraction methods. This proof-of-principle work represents a significant step towards a fully-automated low cost DNA extraction device. - Highlights: • dSPE design on centrifugal PeT device with a unique mixing strategy was proposed. • Increased fluidic control with novel adhesive tape valves on a PeT device. • Multiplexed spin-dSPE device to run up to 4 samples simultaneously. • Demonstrated strong singleplexed and multiplexed amplification following chip dSPE.

  8. On-line neutron activation analyzers

    International Nuclear Information System (INIS)

    Flahaut, V.; Colmon, A.

    1999-01-01

    A neutronic analyser has been designed to determine the composition of the flow of raw materials entering a cement factory on the conveyor belt. This new system gives a reliable analysis of the whole cargo that outdates the sampling or the usual surface analysis based on fluorescence spectrometry. The accuracy is about 1%.The neutrons interact with the materials on an average depth of 25 cm and are absorbed by nuclei, these nuclei produce photons whose energy is characteristic of the chemical element itself. The composition can be deduced by measuring the number of photons emitted and their energy. The analysis is made on-line and can concern the search for about 10 compounds. In the case of cement the list of compounds is: SiO 2 , CaO, Al 2 O 3 , Fe 2 O 3 , MgO, Na 2 O, TiO 2 , S, Mn 2 O 3 , K 2 O, and H 2 O. The neutron generator involves a deuterium ion source whose deuterium ions are accelerated by means of an electrical field and impinge on a tritiated target, the nuclear reactions between deuterium and tritium produce 14 MeV neutrons. This neutron analysing technique can be adapted to any need of on-line composition determination. (A.C.)

  9. Grain-Size Dynamics Beneath Mid-Ocean Ridges: Implications for Permeability and Melt Extraction

    Science.gov (United States)

    Turner, A. J.; Katz, R. F.; Behn, M. D.

    2014-12-01

    The permeability structure of the sub-ridge mantle plays an important role in how melt is focused and extracted at mid-ocean ridges. Permeability is controlled by porosity and the grain size of the solid mantle matrix, which is in turn controlled by the deformation conditions. To date, models of grain size evolution and mantle deformation have not been coupled to determine the influence of spatial variations in grain-size on the permeability structure at mid-ocean ridges. Rather, current models typically assume a constant grain size for the whole domain [1]. Here, we use 2-D numerical models to evaluate the influence of grain-size variability on the permeability structure beneath a mid-ocean ridge and use these results to speculate on the consequences for melt focusing and extraction. We construct a two-dimensional, single phase model for the steady-state grain size beneath a mid-ocean ridge. The model employs a composite rheology of diffusion creep, dislocation creep, dislocation accommodated grain boundary sliding, and a brittle stress limiter. Grain size is calculated using the "wattmeter" model of Austin and Evans [2]. We investigate the sensitivity of the model to global variations in grain growth exponent, potential temperature, spreading-rate, and grain boundary sliding parameters [3,4]. Our model predicts that permeability varies by two orders of magnitude due to the spatial variability of grain size within the expected melt region of a mid-ocean ridge. The predicted permeability structure suggests grain size may promote focusing of melt towards the ridge axis. Furthermore, the calculated grain size structure should focus melt from a greater depth than models that exclude grain-size variability. Future work will involve evaluating this hypothesis by implementing grain-size dynamics within a two-phase mid-ocean ridge model. The developments of such a model will be discussed. References: [1] R. F. Katz, Journal of Petrology, volume 49, issue 12, page 2099

  10. On-Line Core Thermal-Hydraulic Model Improvement

    International Nuclear Information System (INIS)

    In, Wang Kee; Chun, Tae Hyun; Oh, Dong Seok; Shin, Chang Hwan; Hwang, Dae Hyun; Seo, Kyung Won

    2007-02-01

    The objective of this project is to implement a fast-running 4-channel based code CETOP-D in an advanced reactor core protection calculator system(RCOPS). The part required for the on-line calculation of DNBR were extracted from the source of the CETOP-D code based on analysis of the CETOP-D code. The CETOP-D code was revised to maintain the input and output variables which are the same as in CPC DNBR module. Since the DNBR module performs a complex calculation, it is divided into sub-modules per major calculation step. The functional design requirements for the DNBR module is documented and the values of the database(DB) constants were decided. This project also developed a Fortran module(BEST) of the RCOPS Fortran Simulator and a computer code RCOPS-SDNBR to independently calculate DNBR. A test was also conducted to verify the functional design and DB of thermal-hydraulic model which is necessary to calculate the DNBR on-line in RCOPS. The DNBR margin is expected to increase by 2%-3% once the CETOP-D code is used to calculate the RCOPS DNBR. It should be noted that the final DNBR margin improvement could be determined in the future based on overall uncertainty analysis of the RCOPS

  11. On-Line Core Thermal-Hydraulic Model Improvement

    Energy Technology Data Exchange (ETDEWEB)

    In, Wang Kee; Chun, Tae Hyun; Oh, Dong Seok; Shin, Chang Hwan; Hwang, Dae Hyun; Seo, Kyung Won

    2007-02-15

    The objective of this project is to implement a fast-running 4-channel based code CETOP-D in an advanced reactor core protection calculator system(RCOPS). The part required for the on-line calculation of DNBR were extracted from the source of the CETOP-D code based on analysis of the CETOP-D code. The CETOP-D code was revised to maintain the input and output variables which are the same as in CPC DNBR module. Since the DNBR module performs a complex calculation, it is divided into sub-modules per major calculation step. The functional design requirements for the DNBR module is documented and the values of the database(DB) constants were decided. This project also developed a Fortran module(BEST) of the RCOPS Fortran Simulator and a computer code RCOPS-SDNBR to independently calculate DNBR. A test was also conducted to verify the functional design and DB of thermal-hydraulic model which is necessary to calculate the DNBR on-line in RCOPS. The DNBR margin is expected to increase by 2%-3% once the CETOP-D code is used to calculate the RCOPS DNBR. It should be noted that the final DNBR margin improvement could be determined in the future based on overall uncertainty analysis of the RCOPS.

  12. Dynamic-ETL: a hybrid approach for health data extraction, transformation and loading.

    Science.gov (United States)

    Ong, Toan C; Kahn, Michael G; Kwan, Bethany M; Yamashita, Traci; Brandt, Elias; Hosokawa, Patrick; Uhrich, Chris; Schilling, Lisa M

    2017-09-13

    Electronic health records (EHRs) contain detailed clinical data stored in proprietary formats with non-standard codes and structures. Participating in multi-site clinical research networks requires EHR data to be restructured and transformed into a common format and standard terminologies, and optimally linked to other data sources. The expertise and scalable solutions needed to transform data to conform to network requirements are beyond the scope of many health care organizations and there is a need for practical tools that lower the barriers of data contribution to clinical research networks. We designed and implemented a health data transformation and loading approach, which we refer to as Dynamic ETL (Extraction, Transformation and Loading) (D-ETL), that automates part of the process through use of scalable, reusable and customizable code, while retaining manual aspects of the process that requires knowledge of complex coding syntax. This approach provides the flexibility required for the ETL of heterogeneous data, variations in semantic expertise, and transparency of transformation logic that are essential to implement ETL conventions across clinical research sharing networks. Processing workflows are directed by the ETL specifications guideline, developed by ETL designers with extensive knowledge of the structure and semantics of health data (i.e., "health data domain experts") and target common data model. D-ETL was implemented to perform ETL operations that load data from various sources with different database schema structures into the Observational Medical Outcome Partnership (OMOP) common data model. The results showed that ETL rule composition methods and the D-ETL engine offer a scalable solution for health data transformation via automatic query generation to harmonize source datasets. D-ETL supports a flexible and transparent process to transform and load health data into a target data model. This approach offers a solution that lowers technical

  13. Extracting key information from historical data to quantify the transmission dynamics of smallpox

    Directory of Open Access Journals (Sweden)

    Brockmann Stefan O

    2008-08-01

    Full Text Available Abstract Background Quantification of the transmission dynamics of smallpox is crucial for optimizing intervention strategies in the event of a bioterrorist attack. This article reviews basic methods and findings in mathematical and statistical studies of smallpox which estimate key transmission parameters from historical data. Main findings First, critically important aspects in extracting key information from historical data are briefly summarized. We mention different sources of heterogeneity and potential pitfalls in utilizing historical records. Second, we discuss how smallpox spreads in the absence of interventions and how the optimal timing of quarantine and isolation measures can be determined. Case studies demonstrate the following. (1 The upper confidence limit of the 99th percentile of the incubation period is 22.2 days, suggesting that quarantine should last 23 days. (2 The highest frequency (61.8% of secondary transmissions occurs 3–5 days after onset of fever so that infected individuals should be isolated before the appearance of rash. (3 The U-shaped age-specific case fatality implies a vulnerability of infants and elderly among non-immune individuals. Estimates of the transmission potential are subsequently reviewed, followed by an assessment of vaccination effects and of the expected effectiveness of interventions. Conclusion Current debates on bio-terrorism preparedness indicate that public health decision making must account for the complex interplay and balance between vaccination strategies and other public health measures (e.g. case isolation and contact tracing taking into account the frequency of adverse events to vaccination. In this review, we summarize what has already been clarified and point out needs to analyze previous smallpox outbreaks systematically.

  14. On line nuclear orientation: opportunity and challenge

    International Nuclear Information System (INIS)

    Stone, N.J.

    1985-01-01

    The development of the on-line nuclear orientation (OLNO) technique is reviewed. The present potential of the technique is discussed in the light of the attainable temperatures, the use of ion implantation and the required isotope flux. Limitations associated with spin-lattice relaxation are considered in some detail and a survey of accessible nuclei is presented. An outline comparison is given between OLNO and other methods for producing orientation of nuclei, for measuring nuclear spins and static moments and for the study of level structure and transition probabilities. The conclusion is drawn that the method in its present form has extensive potential over a wide range of nuclei. Future prospects for in-beam polarisation giving access to nuclei of shorter half lives are referred to briefly. (Auth.)

  15. An on-line diagnostic expert system

    International Nuclear Information System (INIS)

    Felkel, L.

    1987-01-01

    As experience with on-line information systems, experts systems and artificial intelligence tools grows, the authors retreat from the first euphoria that AI could help them solve the problem they were unable to solve with conventional programming. The major effort of the development time goes into building the knowledge-base. There is no such thing as a generic knowledge-base for nuclear power plants as there is, for example, for the diagnosis of a Boeing 747 aircraft. AI-methods, tools and hardware are still in a state which does not optimally lend itself to real-time application. The ability of developing prototype systems to investigate variants otherwise too costly to justify is one advantage that the authors gladly accept. Last, but no least the tools provide a flexible and adaptable user interface (desktop window systems) etc. The development of such tools in a project would be prohibitive and room for experimentation would be limited

  16. On-Line Algorithms and Reverse Mathematics

    Science.gov (United States)

    Harris, Seth

    In this thesis, we classify the reverse-mathematical strength of sequential problems. If we are given a problem P of the form ∀X(alpha(X) → ∃Zbeta(X,Z)) then the corresponding sequential problem, SeqP, asserts the existence of infinitely many solutions to P: ∀X(∀nalpha(Xn) → ∃Z∀nbeta(X n,Zn)). P is typically provable in RCA0 if all objects involved are finite. SeqP, however, is only guaranteed to be provable in ACA0. In this thesis we exactly characterize which sequential problems are equivalent to RCA0, WKL0, or ACA0.. We say that a problem P is solvable by an on-line algorithm if P can be solved according to a two-player game, played by Alice and Bob, in which Bob has a winning strategy. Bob wins the game if Alice's sequence of plays 〈a0, ..., ak〉 and Bob's sequence of responses 〈 b0, ..., bk〉 constitute a solution to P. Formally, an on-line algorithm A is a function that inputs an admissible sequence of plays 〈a 0, b0, ..., aj〉 and outputs a new play bj for Bob. (This differs from the typical definition of "algorithm", though quite often a concrete set of instructions can be easily deduced from A.). We show that SeqP is provable in RCA0 precisely when P is solvable by an on-line algorithm. Schmerl proved this result specifically for the graph coloring problem; we generalize Schmerl's result to any problem that is on-line solvable. To prove our separation, we introduce a principle called Predictk(r) that is equivalent to -WKL0 for standard k, r.. We show that WKL0 is sufficient to prove SeqP precisely when P has a solvable closed kernel. This means that a solution exists, and each initial segment of this solution is a solution to the corresponding initial segment of the problem. (Certain bounding conditions are necessary as well.) If no such solution exists, then SeqP is equivalent to ACA0 over RCA 0 + ISigma02; RCA0 alone suffices if only sequences of standard length are considered. We use different techniques from Schmerl to prove

  17. Software for on-line experiments

    International Nuclear Information System (INIS)

    Ivanchenko, I.M.

    1981-01-01

    A review of nowadays development state of software of on-line electron experiments is presented. The principles of organization of real time systems on second generation computer base are considered. The following methods for projections search are considered: combinator methods, global methods, methods of tracking, methods of a supporting band. The following methods for determining parameter estimates based on the Lorentz equation are analysed: analytical simulation of trajectories, determination of parameters by the iterative method using the technique of calculation of recycled integrals, multidimensional statistical analysis. For the purpose of successful usage and development of software the technique of selfdocumented programs is created and the computer is applied for preparing, revising and circulation of external descriptions which as program complexes are constructed according to the hierarchical principle [ru

  18. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  19. Aprender a innovar: una experiencia on line

    Directory of Open Access Journals (Sweden)

    Joaquín MORENO MARCHAL

    2014-11-01

    Full Text Available La creatividad y la innovación se han convertido en recursos clave en la denominada sociedad del conocimiento, que bien podría ser también llamada sociedad de la innovación. Pero innovar es una actividad compleja, que integra la aplicación de múltiples capacidades, el pensamiento divergente y convergente, la gestión de equipos humanos, la comunicación. Ahora bien, a innovar se puede, y se debe, aprender. Aprender a innovar es un reto y también una obligación para el conjunto del sistema educativo en todos sus niveles. Partiendo de estas consideraciones este trabajo expone una experiencia de aprendizaje de la creatividad y de la innovación a través de un curso totalmente on line basado en la plataforma MOODLE, en el marco del Programa de Formación Permanente de la Universidad de Cádiz. Se presenta un modelo del proceso de innovación, denominado CREALAB, de elaboración propia. Este modelo se ha utilizado como base del proceso de aprendizaje de la creatividad y de la innovación y en el diseño del curso, está organizado en torno a actividades y tiene un carácter iterativo y realimentado. Se presentan además el conjunto del diseño metodológico y los resultados obtenidos en las dos ediciones celebradas hasta el momento. El diseño del curso totalmente on line y los resultados alcanzados permiten estimar un alto potencial de aplicación, tanto a nivel personal como a nivel organizacional.

  20. Molecular dynamics simulations of the interactions of medicinal plant extracts and drugs with lipid bilayer membranes

    DEFF Research Database (Denmark)

    Kopec, Wojciech; Telenius, Jelena; Khandelia, Himanshu

    2013-01-01

    Several small drugs and medicinal plant extracts, such as the Indian spice extract curcumin, have a wide range of useful pharmacological properties that cannot be ascribed to binding to a single protein target alone. The lipid bilayer membrane is thought to mediate the effects of many such molecu......Several small drugs and medicinal plant extracts, such as the Indian spice extract curcumin, have a wide range of useful pharmacological properties that cannot be ascribed to binding to a single protein target alone. The lipid bilayer membrane is thought to mediate the effects of many...

  1. On-line Social Interactions and Executive Functions

    Directory of Open Access Journals (Sweden)

    Oscar eYbarra

    2012-04-01

    Full Text Available A successful social interaction requires fast, on-line, and active construction of an ever-changing mental-model of another’s person beliefs, expectations, emotions, and desires. It also requires the ability to inhibit inappropriate behaviors, problem-solve, take-turns, and pursue goals in a distraction-rich environment. All these tasks rely on executive functions (EF—working memory, attention/cognitive control, and inhibition. Executive functioning has long been viewed as relatively static. However, starting with recent reports of successful cognitive interventions, this view is changing and now EFs are seen as much more open to both short and long term training, warm-up, and exhaustion effects. Some of the most intriguing evidence comes from research showing how social interaction enhances performance on standard EF tests. Interestingly, the latest research indicates these EF benefits are selectively conferred by certain on-line, dynamic social interactions, which require participants to engage with another person and actively construct the model of their mind. We review this literature and highlight its connection with evolutionary and cultural theories emphasizing links between intelligence and social life.

  2. A High-Speed Vision-Based Sensor for Dynamic Vibration Analysis Using Fast Motion Extraction Algorithms

    Directory of Open Access Journals (Sweden)

    Dashan Zhang

    2016-04-01

    Full Text Available The development of image sensor and optics enables the application of vision-based techniques to the non-contact dynamic vibration analysis of large-scale structures. As an emerging technology, a vision-based approach allows for remote measuring and does not bring any additional mass to the measuring object compared with traditional contact measurements. In this study, a high-speed vision-based sensor system is developed to extract structure vibration signals in real time. A fast motion extraction algorithm is required for this system because the maximum sampling frequency of the charge-coupled device (CCD sensor can reach up to 1000 Hz. Two efficient subpixel level motion extraction algorithms, namely the modified Taylor approximation refinement algorithm and the localization refinement algorithm, are integrated into the proposed vision sensor. Quantitative analysis shows that both of the two modified algorithms are at least five times faster than conventional upsampled cross-correlation approaches and achieve satisfactory error performance. The practicability of the developed sensor is evaluated by an experiment in a laboratory environment and a field test. Experimental results indicate that the developed high-speed vision-based sensor system can extract accurate dynamic structure vibration signals by tracking either artificial targets or natural features.

  3. Effects of pyrite and sphalerite on population compositions, dynamics and copper extraction efficiency in chalcopyrite bioleaching process.

    Science.gov (United States)

    Xiao, Yunhua; Liu, Xueduan; Dong, Weiling; Liang, Yili; Niu, Jiaojiao; Gu, Yabing; Ma, Liyuan; Hao, Xiaodong; Zhang, Xian; Xu, Zhen; Yin, Huaqun

    2017-07-01

    This study used an artificial microbial community with four known moderately thermophilic acidophiles (three bacteria including Acidithiobacillus caldus S1, Sulfobacillus thermosulfidooxidans ST and Leptospirillum ferriphilum YSK, and one archaea, Ferroplasma thermophilum L1) to explore the variation of microbial community structure, composition, dynamics and function (e.g., copper extraction efficiency) in chalcopyrite bioleaching (C) systems with additions of pyrite (CP) or sphalerite (CS). The community compositions and dynamics in the solution and on the ore surface were investigated by real-time quantitative PCR (qPCR). The results showed that the addition of pyrite or sphalerite changed the microbial community composition and dynamics dramatically during the chalcopyrite bioleaching process. For example, A. caldus (above 60%) was the dominant species at the initial stage in three groups, and at the middle stage, still dominated C group (above 70%), but it was replaced by L. ferriphilum (above 60%) in CP and CS groups; at the final stage, L. ferriphilum dominated C group, while F. thermophilum dominated CP group on the ore surface. Furthermore, the additions of pyrite or sphalerite both made the increase of redox potential (ORP) and the concentrations of Fe 3+ and H + , which would affect the microbial community compositions and copper extraction efficiency. Additionally, pyrite could enhance copper extraction efficiency (e.g., improving around 13.2% on day 6) during chalcopyrite bioleaching; on the contrary, sphalerite restrained it.

  4. Assessing oral bioaccessibility of trace elements in soils under worst-case scenarios by automated in-line dynamic extraction as a front end to inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rosende, María [FI-TRACE group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa, km 7.5, Palma de Mallorca, Illes Balears E-07122 (Spain); Magalhães, Luis M.; Segundo, Marcela A. [REQUIMTE, Department of Chemistry, Faculty of Pharmacy, University of Porto, R. de Jorge Viterbo Ferreira, 228, Porto 4050-313 (Portugal); Miró, Manuel, E-mail: manuel.miro@uib.es [FI-TRACE group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa, km 7.5, Palma de Mallorca, Illes Balears E-07122 (Spain)

    2014-09-09

    Highlights: • Automatic oral bioaccessibility tests of trace metals under worst-case scenarios. • Use of intricate and realistic digestive fluids (UBM method). • Analysis of large amounts of soils (≥400 mg) in a flow-based configuration. • Smart interface to inductively coupled plasma atomic emission spectrometry. • Comparison of distinct flow systems mimicking physiological conditions. - Abstract: A novel biomimetic extraction procedure that allows for the in-line handing of ≥400 mg solid substrates is herein proposed for automatic ascertainment of trace element (TE) bioaccessibility in soils under worst-case conditions as per recommendations of ISO norms. A unified bioaccessibility/BARGE method (UBM)-like physiological-based extraction test is evaluated for the first time in a dynamic format for accurate assessment of in-vitro bioaccessibility of Cr, Cu, Ni, Pb and Zn in forest and residential-garden soils by on-line coupling of a hybrid flow set-up to inductively coupled plasma atomic emission spectrometry. Three biologically relevant operational extraction modes mimicking: (i) gastric juice extraction alone; (ii) saliva and gastric juice composite in unidirectional flow extraction format and (iii) saliva and gastric juice composite in a recirculation mode were thoroughly investigated. The extraction profiles of the three configurations using digestive fluids were proven to fit a first order reaction kinetic model for estimating the maximum TE bioaccessibility, that is, the actual worst-case scenario in human risk assessment protocols. A full factorial design, in which the sample amount (400–800 mg), the extractant flow rate (0.5–1.5 mL min{sup −1}) and the extraction temperature (27–37 °C) were selected as variables for the multivariate optimization studies in order to obtain the maximum TE extractability. Two soils of varied physicochemical properties were analysed and no significant differences were found at the 0.05 significance level

  5. Assessing oral bioaccessibility of trace elements in soils under worst-case scenarios by automated in-line dynamic extraction as a front end to inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Rosende, María; Magalhães, Luis M.; Segundo, Marcela A.; Miró, Manuel

    2014-01-01

    Highlights: • Automatic oral bioaccessibility tests of trace metals under worst-case scenarios. • Use of intricate and realistic digestive fluids (UBM method). • Analysis of large amounts of soils (≥400 mg) in a flow-based configuration. • Smart interface to inductively coupled plasma atomic emission spectrometry. • Comparison of distinct flow systems mimicking physiological conditions. - Abstract: A novel biomimetic extraction procedure that allows for the in-line handing of ≥400 mg solid substrates is herein proposed for automatic ascertainment of trace element (TE) bioaccessibility in soils under worst-case conditions as per recommendations of ISO norms. A unified bioaccessibility/BARGE method (UBM)-like physiological-based extraction test is evaluated for the first time in a dynamic format for accurate assessment of in-vitro bioaccessibility of Cr, Cu, Ni, Pb and Zn in forest and residential-garden soils by on-line coupling of a hybrid flow set-up to inductively coupled plasma atomic emission spectrometry. Three biologically relevant operational extraction modes mimicking: (i) gastric juice extraction alone; (ii) saliva and gastric juice composite in unidirectional flow extraction format and (iii) saliva and gastric juice composite in a recirculation mode were thoroughly investigated. The extraction profiles of the three configurations using digestive fluids were proven to fit a first order reaction kinetic model for estimating the maximum TE bioaccessibility, that is, the actual worst-case scenario in human risk assessment protocols. A full factorial design, in which the sample amount (400–800 mg), the extractant flow rate (0.5–1.5 mL min −1 ) and the extraction temperature (27–37 °C) were selected as variables for the multivariate optimization studies in order to obtain the maximum TE extractability. Two soils of varied physicochemical properties were analysed and no significant differences were found at the 0.05 significance level

  6. Dynamics of dissolved and extractable organic nitrogen upon soil amendment with crop residues

    NARCIS (Netherlands)

    Ros, G.H.; Hoffland, E.

    2010-01-01

    Dissolved organic nitrogen (DON) is increasingly recognized as a pivotal pool in the soil nitrogen (N) cycle. Numerous devices and sampling procedures have been used to estimate its size, varying from in situ collection of soil solution to extraction of dried soil with salt solutions. Extractable

  7. Respirometry-based on-line model parameter estimation at a full-scale WWTP

    NARCIS (Netherlands)

    Spanjers, H.; Patry, G.G.; Keesman, K.J.

    2002-01-01

    This paper describes part of a project to develop a systematic approach to knowledge extraction from on-line respirometric measurements in support of wastewater treatment plant control and operation. The paper deals with the following issues: (1) test of the implementation of an automatic set-up

  8. The isotope separator on-line at the INS-SF cyclotron

    International Nuclear Information System (INIS)

    Yonehara, H.; Kawakami, H.; Tanaka, J.; Omata, K.; Shida, Y.

    1981-02-01

    The Isotope Separator On-Line at the SF Cyclotron has been improved. Some details of improvements are described on the target-ion source, rapid extraction with aluminized tape, tape transport system and data aquisition. The performance of the improved SF-ISOL is discussed. (author)

  9. On-line control of nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Parus, I.; Kierzek, J.; Zoltowski, T.

    1977-01-01

    The development trends in the field of chemical processes control and the present state of the development of continuous composition analysers has been described. On this background the peculiarities of on-line control methods for spent nuclear fuel reprocessing have been discussed. The measuring methods for direct and indirect determination of chemical composition and nuclear safety are reviewed in detail. The review comprises such methods as: measurement of α, γ and neutron radiation emitted both by nuclides present in technological solutions and using external sources of different radiation, X-ray fluorescence, measurements of physicochemical parameters connected with the composition (pH, density, electrical conductivity), polarography and spectrophotometry. At the end of this review some new trends in process control based on dynamic process models have been presented. (author)

  10. On-line monitoring of main coolant pump seals

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; Glass, S.W.; Sommerfield, G.A.; Harrison, D.

    1984-06-01

    The Babcock and Wilcox Company has developed and implemented a Reactor Coolant Pump Monitoring and Diagnostic System (RCPM and DS). The system has been installed at Toledo Edison Company's Davis-Besse Nuclear Power Station Unit 1. The RCPM and PS continuously monitors a number of indicators of pump performance and notifies the plant operator of out-of-tolerance conditions or pump performance trending toward out-of-tolerance conditions. Pump seal parameters being monitored include pump internal pressures, temperatures, and flow rates. Rotordynamic performanvce and plant operating conditions are also measured with a variety of dynamic sensors. This paper describes the implementation of the system and the results of on-line monitoring of four RC pumps

  11. Sol-gel titania-coated needles for solid phase dynamic extraction-GC/MS analysis of desomorphine and desocodeine.

    Science.gov (United States)

    Su, Chi-Ju; Srimurugan, Sankarewaran; Chen, Chinpiao; Shu, Hun-Chi

    2011-01-01

    Novel sol-gel titania film coated needles for solid-phase dynamic extraction (SPDE)-GC/MS analysis of desomorphine and desocodeine are described. The high thermal stability of titania film permits efficient extraction and analysis of poorly volatile opiate drugs. The influences of sol-gel reaction time, coating layer, extraction and desorption time and temperature on the SPDE needle performance were investigated. The deuterium labeled internal standard was introduced either during the extraction of analyte or directly injected to GC after the extraction process. The latter method was shown to be more sensitive for the analysis of water and urine samples containing opiate drugs. The proposed conditions provided a wide linear range (from 5-5000 ppb), and satisfactory linearity, with R(2) values from 0.9958 to 0.9999, and prominent sensitivity, LOQs (1.0-5.0 ng/g). The sol-gel titania film coated needle with SPDE-GC/MS will be a promising technique for desomorphine and desocodeine analysis in urine.

  12. Information extraction from dynamic PS-InSAR time series using machine learning

    Science.gov (United States)

    van de Kerkhof, B.; Pankratius, V.; Chang, L.; van Swol, R.; Hanssen, R. F.

    2017-12-01

    Due to the increasing number of SAR satellites, with shorter repeat intervals and higher resolutions, SAR data volumes are exploding. Time series analyses of SAR data, i.e. Persistent Scatterer (PS) InSAR, enable the deformation monitoring of the built environment at an unprecedented scale, with hundreds of scatterers per km2, updated weekly. Potential hazards, e.g. due to failure of aging infrastructure, can be detected at an early stage. Yet, this requires the operational data processing of billions of measurement points, over hundreds of epochs, updating this data set dynamically as new data come in, and testing whether points (start to) behave in an anomalous way. Moreover, the quality of PS-InSAR measurements is ambiguous and heterogeneous, which will yield false positives and false negatives. Such analyses are numerically challenging. Here we extract relevant information from PS-InSAR time series using machine learning algorithms. We cluster (group together) time series with similar behaviour, even though they may not be spatially close, such that the results can be used for further analysis. First we reduce the dimensionality of the dataset in order to be able to cluster the data, since applying clustering techniques on high dimensional datasets often result in unsatisfying results. Our approach is to apply t-distributed Stochastic Neighbor Embedding (t-SNE), a machine learning algorithm for dimensionality reduction of high-dimensional data to a 2D or 3D map, and cluster this result using Density-Based Spatial Clustering of Applications with Noise (DBSCAN). The results show that we are able to detect and cluster time series with similar behaviour, which is the starting point for more extensive analysis into the underlying driving mechanisms. The results of the methods are compared to conventional hypothesis testing as well as a Self-Organising Map (SOM) approach. Hypothesis testing is robust and takes the stochastic nature of the observations into account

  13. Anode plasma dynamics in an extraction applied-B ion diode: effects on divergence, ion species and parasitic load

    International Nuclear Information System (INIS)

    Greenly, J.B.; Appartaim, R.K.; Olson, J.C.

    1996-01-01

    Analysis of data from the LION (1.2 MV, 300 kA, 40 ns) extraction applied-B diode allows a number of inferences regarding the effect of anode plasma dynamics on ion beam divergence, ion species composition, and diode impedance and power coupling. The two dominant features of anode plasma dynamics observed on LION are (1) plasma expansion away from the solid anode surface and into the accelerating gap during the beam pulse, and (2) evolution of the composition of the plasma during the pulse. The data presented in this paper characterize the plasma expansion, and suggest a possible picture of the mechanism of the plasma dynamics that could produce these basic features. (J.U.). 2 figs., 5 refs

  14. Anode plasma dynamics in an extraction applied-B ion diode: effects on divergence, ion species and parasitic load

    Energy Technology Data Exchange (ETDEWEB)

    Greenly, J B; Appartaim, R K; Olson, J C [Cornell Univ., Ithaca, NY (United States). Lab. of Plasma Studies

    1997-12-31

    Analysis of data from the LION (1.2 MV, 300 kA, 40 ns) extraction applied-B diode allows a number of inferences regarding the effect of anode plasma dynamics on ion beam divergence, ion species composition, and diode impedance and power coupling. The two dominant features of anode plasma dynamics observed on LION are (1) plasma expansion away from the solid anode surface and into the accelerating gap during the beam pulse, and (2) evolution of the composition of the plasma during the pulse. The data presented in this paper characterize the plasma expansion, and suggest a possible picture of the mechanism of the plasma dynamics that could produce these basic features. (J.U.). 2 figs., 5 refs.

  15. On-line maintenance at Cofrentes NPP

    International Nuclear Information System (INIS)

    Roldan Vilches, J.; Moreno Matarranz, M. A.; Hermana Mendioroz, I.

    1998-01-01

    Cofrentes NPP has begun in 1997 activities related to At Power Preventive Maintenance over trains or systems which lead to a voluntary entry in a Limitative Condition of Operation (LCO) of the Technical Specifications. From others benefits, this program ha improved the risk management and the staff's knowledge over the functions and safety implications of the different systems, the better exploit of the resources, the co-ordination of the different organisations involved (Maintenance an Operation) and the reductions of works during shutdowns. Previous to each work, a feasibility study analyzes qualitative and quantitative (PSA), using the Risk Monitor, the implications on safety of all the tasks, assuring that the global safety of the Plant is always maintained. Tech. Spec. are analyzed in detail and also are analyzed situations of simultaneous unavailabilities of systems which could lead to a high risk situation. Two different risk controls are defined (punctual and accumulated) to assure that high risk situations will not be given. Finally, historical risk profile is analyzed to assure that the accumulated risk increase is not significant. Risk Monitor helps staff in the schedule and follow-up of the activities of On-Line Maintenance. Each one of the tasks are deeply planned and harshly analyzed and are carried out by high qualified workers. By the moment, this program is running with fully satisfaction on the Plant. (Author)

  16. SOL: INNOVACIÓN ON-LINE

    Directory of Open Access Journals (Sweden)

    Rubén Faúndez

    2007-11-01

    Full Text Available Las aplicaciones de simulación tienden a ser cada vez más cercanas a usuarios e industrias. Sin embargo, muchas de ellas no poseen ni la capacidad ni el conocimiento como para desarrollar internamente sus modelos de simulación. Por este motivo, y como una forma de apoyar la toma de decisiones basándose en modelos de simulación, se presenta la plataforma SOL (Simulación On Line. La metodología completa de trabajo, así como la interacción entre SOL, Empresa y Asesor, son presentadas. Su base de datos, los niveles de usuarios, sus funcionalidades, y la creación automatizada de información grafica y visual, también son explicadas. En el caso de aplicación, el uso de SOL para apoyar la toma de decisiones en una operación de movimiento de material, permite a los tomadores de decisión acceder a análisis robustos basados en información extraída de los modelos de simulación. SOL, al almacenar información, funcionar vía web, generar análisis automatizados y crear visualizaciones, permite cumplir con las expectativas de los usuarios respecto a una solución integral en simulación.

  17. Simplified automatic on-line document searching

    International Nuclear Information System (INIS)

    Ebinuma, Yukio

    1983-01-01

    The author proposed searching method for users who need not-comprehensive retrieval. That is to provide flexible number of related documents for the users automatically. A group of technical terms are used as search terms to express an inquiry. Logical sums of the terms in the ascending order of frequency of the usage are prepared sequentially and automatically, and then the search formulas, qsub(m) and qsub(m-1) which meet certain threshold values are selected automatically also. Users justify precision of the search output up to 20 items retrieved by the formula qsub(m). If a user wishes more than 30% of recall ratio, the serach result should be output by qsub(m), and if he wishes less than 30% of it, it should be output by qsub(m-1). The search by this method using one year volume of INIS Database (76,600 items) and five inquiries resulted in 32% of recall ratio and 36% of precision ratio on the average in the case of qsub(m). The connecting time of a terminal was within 15 minutes per an inquiry. It showed more efficiency than that of an inexperienced searcher. The method can be applied to on-line searching system for database in which natural language only or natural language and controlled vocabulary are used. (author)

  18. Application of on-line analytical processing technique in accelerator

    International Nuclear Information System (INIS)

    Xie Dong; Li Weimin; He Duohui; Liu Gongfa; Xuan Ke

    2005-01-01

    A method of application of the on-line analytical processing technique in accelerator is described, which includes data pre-processing, the process of constructing of data warehouse and on-line analytical processing. (authors)

  19. Simultaneous Determination of Palladium and Platinum by On-line ...

    African Journals Online (AJOL)

    NJD

    using high performance liquid chromatography equipped with an on-line enrichment technique. Prior to ... The on-line enrichment system (Waters Corporation, USA) that was ... Using an appropriate volume (industrial plant effluents 20 mL,.

  20. Influence of visualization on consumption during on-line shopping

    OpenAIRE

    Hictaler, Urška

    2013-01-01

    This diploma work studies the influence of visualization on consumption during on-line shopping. The first part of the thesis starts with key areas of visualization, consumption and on-line shopping. Visualization, areas of use, human perception and ways of product presentation in on-line shops are defined discussed first. Next, consumption, consumers and factors that influence their decisions and satisfaction are defined. The last topic in the first part of the thesis discusses on-line shopp...

  1. A Distributed System for Learning Programming On-Line

    Science.gov (United States)

    Verdu, Elena; Regueras, Luisa M.; Verdu, Maria J.; Leal, Jose P.; de Castro, Juan P.; Queiros, Ricardo

    2012-01-01

    Several Web-based on-line judges or on-line programming trainers have been developed in order to allow students to train their programming skills. However, their pedagogical functionalities in the learning of programming have not been clearly defined. EduJudge is a project which aims to integrate the "UVA On-line Judge", an existing…

  2. Trend extraction of rail corrugation measured dynamically based on the relevant low-frequency principal components reconstruction

    International Nuclear Information System (INIS)

    Li, Yanfu; Liu, Hongli; Ma, Ziji

    2016-01-01

    Rail corrugation dynamic measurement techniques are critical to guarantee transport security and guide rail maintenance. During the inspection process, low-frequency trends caused by rail fluctuation are usually superimposed on rail corrugation and seriously affect the assessment of rail maintenance quality. In order to extract and remove the nonlinear and non-stationary trends from original mixed signals, a hybrid model based ensemble empirical mode decomposition (EEMD) and modified principal component analysis (MPCA) is proposed in this paper. Compared with the existing de-trending methods based on EMD, this method first considers low-frequency intrinsic mode functions (IMFs) thought to be underlying trend components that maybe contain some unrelated components, such as white noise and low-frequency signal itself, and proposes to use PCA to accurately extract the pure trends from the IMFs containing multiple components. On the other hand, due to the energy contribution ratio between trends and mixed signals is prior unknown, and the principal components (PCs) decomposed by PCA are arranged in order of energy reduction without considering frequency distribution, the proposed method modifies traditional PCA and just selects relevant low-frequency PCs to reconstruct the trends based on the zero-crossing numbers (ZCN) of each PC. Extensive tests are presented to illustrate the effectiveness of the proposed method. The results show the proposed EEMD-PCA-ZCN is an effective tool for trend extraction of rail corrugation measured dynamically. (paper)

  3. On-line monitoring of methane in sewer air.

    Science.gov (United States)

    Liu, Yiwen; Sharma, Keshab R; Murthy, Sudhir; Johnson, Ian; Evans, Ted; Yuan, Zhiguo

    2014-10-16

    Methane is a highly potent greenhouse gas and contributes significantly to climate change. Recent studies have shown significant methane production in sewers. The studies conducted so far have relied on manual sampling followed by off-line laboratory-based chromatography analysis. These methods are labor-intensive when measuring methane emissions from a large number of sewers, and do not capture the dynamic variations in methane production. In this study, we investigated the suitability of infrared spectroscopy-based on-line methane sensors for measuring methane in humid and condensing sewer air. Two such sensors were comprehensively tested in the laboratory. Both sensors displayed high linearity (R(2) > 0.999), with a detection limit of 0.023% and 0.110% by volume, respectively. Both sensors were robust against ambient temperature variations in the range of 5 to 35°C. While one sensor was robust against humidity variations, the other was found to be significantly affected by humidity. However, the problem was solved by equipping the sensor with a heating unit to increase the sensor surface temperature to 35°C. Field studies at three sites confirmed the performance and accuracy of the sensors when applied to actual sewer conditions, and revealed substantial and highly dynamic methane concentrations in sewer air.

  4. Deformable motion reconstruction for scanned proton beam therapy using on-line x-ray imaging

    NARCIS (Netherlands)

    Zhang, Ye; Knopf, A; Tanner, Colby; Boye, Dirk; Lomax, Antony J.

    2013-01-01

    Organ motion is a major problem for any dynamic radiotherapy delivery technique, and is particularly so for spot scanned proton therapy. On the other hand, the use of narrow, magnetically deflected proton pencil beams is potentially an ideal delivery technique for tracking tumour motion on-line. At

  5. Extraction of left ventricular myocardial mass from dynamic 11C-acetate PET

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    Background: Dynamic 11C-acetate PET is used to quantify oxygen metabolism, which is used to calculate left ventricular (LV) myocardial efficiency, an early marker of heart failure. This requires estimation of LV myocardial mass and is typically derived from a separate cardiovascular magnetic...... resonance (CMR) scan. The aim of this study was to explore the feasibility of estimating myocardial mass directly from a dynamic 11C-acetate PET scan. Methods: 21 subjects underwent a 27-min 11C-acetate PET scan on a Siemens Biograph TruePoint 64 PET/CT scanner. In addition, 10 subjects underwent a dynamic...... 11C-acetate 27-min PET scan on a GE Discovery ST PET/CT scanner. Parametric images of uptake rate K1 and both arterial (VA) and venous (VV) spillover fractions were generated using a basis function implementation of the standard single tissue compartment model using non-gated dynamic data. The LV...

  6. Dynamics and control of a heat pump assisted extractive dividing-wall column for bioethanol dehydration

    NARCIS (Netherlands)

    Patraşcu, Iulian; Bildea, Costin Sorin; Kiss, Anton A.

    Recently, a novel heat-pump-assisted extractive distillation process taking place in a dividing-wall column was proposed for bioethanol dehydration. This integrated design combines three distillation columns into a single unit that allows over 40% energy savings and low specific energy requirements

  7. Synergistic effect of dicarbollide anions in liquid-liquid extraction: a molecular dynamics study at the octanol-water interface.

    Science.gov (United States)

    Chevrot, G; Schurhammer, R; Wipff, G

    2007-04-28

    We report a molecular dynamics study of chlorinated cobalt bis(dicarbollide) anions [(B(9)C(2)H(8)Cl(3))(2)Co](-)"CCD(-)" in octanol and at the octanol-water interface, with the main aim to understand why these hydrophobic species act as strong synergists in assisted liquid-liquid cation extraction. Neat octanol is quite heterogeneous and is found to display dual solvation properties, allowing to well solubilize CCD(-), Cs(+) salts in the form of diluted pairs or oligomers, without displaying aggregation. At the aqueous interface, octanol behaves as an amphiphile, forming either monolayers or bilayers, depending on the initial state and confinement conditions. In biphasic octanol-water systems, CCD(-) anions are found to mainly partition to the organic phase, thus attracting Cs(+) or even more hydrophilic counterions like Eu(3+) into that phase. The remaining CCD(-) anions adsorb at the interface, but are less surface active than at the chloroform interface. Finally, we compare the interfacial behavior of the Eu(BTP)(3)(3+) complex in the absence and in the presence of CCD(-) anions and extractant molecules. It is found that when the CCD(-)'s are concentrated enough, the complex is extracted to the octanol phase. Otherwise, it is trapped at the interface, attracted by water. These results are compared to those obtained with chloroform as organic phase and discussed in the context of synergistic effect of CCD(-) in liquid-liquid extraction, pointing to the importance of dual solvation properties of octanol and of the hydrophobic character of CCD(-) for synergistic extraction of cations.

  8. Improving the quality of extracting dynamics from interspike intervals via a resampling approach

    Science.gov (United States)

    Pavlova, O. N.; Pavlov, A. N.

    2018-04-01

    We address the problem of improving the quality of characterizing chaotic dynamics based on point processes produced by different types of neuron models. Despite the presence of embedding theorems for non-uniformly sampled dynamical systems, the case of short data analysis requires additional attention because the selection of algorithmic parameters may have an essential influence on estimated measures. We consider how the preliminary processing of interspike intervals (ISIs) can increase the precision of computing the largest Lyapunov exponent (LE). We report general features of characterizing chaotic dynamics from point processes and show that independently of the selected mechanism for spike generation, the performed preprocessing reduces computation errors when dealing with a limited amount of data.

  9. Automatic extraction of myocardial mass and volumes using parametric images from dynamic nongated PET

    DEFF Research Database (Denmark)

    Harms, Hendrik Johannes; Hansson, Nils Henrik Stubkjær; Tolbod, Lars Poulsen

    2016-01-01

    Dynamic cardiac positron emission tomography (PET) is used to quantify molecular processes in vivo. However, measurements of left-ventricular (LV) mass and volumes require electrocardiogram (ECG)-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using non......-gated dynamic cardiac PET. METHODS: Thirty-five patients with aortic-valve stenosis and 10 healthy controls (HC) underwent a 27-min 11C-acetate PET/CT scan and cardiac magnetic resonance imaging (CMR). HC were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were......LV and WT only and an overestimation for LVEF at lower values. Intra- and inter-observer correlations were >0.95 for all PET measurements. PET repeatability accuracy in HC was comparable to CMR. CONCLUSION: LV mass and volumes are accurately and automatically generated from dynamic 11C-acetate PET without...

  10. Near infrared spectroscopy based monitoring of extraction processes of raw material with the help of dynamic predictive modeling

    Science.gov (United States)

    Wang, Haixia; Suo, Tongchuan; Wu, Xiaolin; Zhang, Yue; Wang, Chunhua; Yu, Heshui; Li, Zheng

    2018-03-01

    The control of batch-to-batch quality variations remains a challenging task for pharmaceutical industries, e.g., traditional Chinese medicine (TCM) manufacturing. One difficult problem is to produce pharmaceutical products with consistent quality from raw material of large quality variations. In this paper, an integrated methodology combining the near infrared spectroscopy (NIRS) and dynamic predictive modeling is developed for the monitoring and control of the batch extraction process of licorice. With the spectra data in hand, the initial state of the process is firstly estimated with a state-space model to construct a process monitoring strategy for the early detection of variations induced by the initial process inputs such as raw materials. Secondly, the quality property of the end product is predicted at the mid-course during the extraction process with a partial least squares (PLS) model. The batch-end-time (BET) is then adjusted accordingly to minimize the quality variations. In conclusion, our study shows that with the help of the dynamic predictive modeling, NIRS can offer the past and future information of the process, which enables more accurate monitoring and control of process performance and product quality.

  11. Dynamics and control of a heat pump assisted extractive dividing-wall column for bioethanol dehydration

    OpenAIRE

    Patraşcu, Iulian; Bildea, Costin Sorin; Kiss, Anton A.

    2017-01-01

    Recently, a novel heat-pump-assisted extractive distillation process taking place in a dividing-wall column was proposed for bioethanol dehydration. This integrated design combines three distillation columns into a single unit that allows over 40% energy savings and low specific energy requirements of 1.24 kWh/kg ethanol. However, these economic benefits are possible only if this highly integrated system is also controllable to ensure operational availability. This paper is the first to addre...

  12. Probabilistic Forecasting for On-line Operation of Urban Drainage Systems

    DEFF Research Database (Denmark)

    Löwe, Roland

    This thesis deals with the generation of probabilistic forecasts in urban hydrology. In particular, we focus on the case of runoff forecasting for real-time control (RTC) on horizons of up to two hours. For the generation of probabilistic on-line runoff forecasts, we apply the stochastic grey...... and forecasts have on on-line runoff forecast quality. Finally, we implement the stochastic grey-box model approach in a real-world real-time control (RTC) setup and study how RTC can benefit from a dynamic quantification of runoff forecast uncertainty....

  13. Influences of groundwater extraction on flow dynamics and arsenic levels in the western Hetao Basin, Inner Mongolia, China

    Science.gov (United States)

    Zhang, Zhuo; Guo, Huaming; Zhao, Weiguang; Liu, Shuai; Cao, Yongsheng; Jia, Yongfeng

    2018-04-01

    Data on spatiotemporal variations in groundwater levels are crucial for understanding arsenic (As) behavior and dynamics in groundwater systems. Little is known about the influences of groundwater extraction on the transport and mobilization of As in the Hetao Basin, Inner Mongolia (China), so groundwater levels were recorded in five monitoring wells from 2011 to 2016 and in 57 irrigation wells and two multilevel wells in 2016. Results showed that groundwater level in the groundwater irrigation area had two troughs each year, induced by extensive groundwater extraction, while groundwater levels in the river-diverted (Yellow River) water irrigation area had two peaks each year, resulting from surface-water irrigation. From 2011 to 2016, groundwater levels in the groundwater irrigation area presented a decreasing trend due to the overextraction. Groundwater samples were taken for geochemical analysis each year in July from 2011 to 2016. Increasing trends were observed in groundwater total dissolved solids (TDS) and As. Owing to the reverse groundwater flow direction, the Shahai Lake acts as a new groundwater recharge source. Lake water had flushed the near-surface sediments, which contain abundant soluble components, and increased groundwater salinity. In addition, groundwater extraction induced strong downward hydraulic gradients, which led to leakage recharge from shallow high-TDS groundwater to the deep semiconfined aquifer. The most plausible explanation for similar variations among As, Fe(II) and total organic carbon (TOC) concentrations is the expected dissimilatory reduction of Fe(III) oxyhydroxides.

  14. Factors affecting re-vegetation dynamics of experimentally restored extracted peatland in Estonia.

    Science.gov (United States)

    Karofeld, Edgar; Müür, Mari; Vellak, Kai

    2016-07-01

    Increasing human activity continues to threaten peatlands, and as the area of natural mires declines, our obligation is to restore their ecosystem functions. Several restoration strategies have been developed for restoration of extracted peatlands, including "The moss layer transfer method", which was initiated on the Tässi extracted peatland in central Estonia in May 2012. Three-year study shows that despite the fluctuating water table, rainfall events can compensate for the insufficient moisture for mosses. Total plant cover on the restoration area attained 70 %, of which ~60 % is comprised of target species-Sphagnum mosses. From restoration treatments, spreading of plant fragments had a significant positive effect on the cover of bryophyte and vascular plants. Higher water table combined with higher plant fragments spreading density and stripping of oxidised peat layer affected positively the cover of targeted Sphagnum species. The species composition in the restoration area became similar to that in the donor site in a natural bog. Based on results, it was concluded that the method approved for restoration in North America gives good results also in the restoration of extracted peatland towards re-establishment of bog vegetation under northern European conditions.

  15. DOE-EPRI On-Line Monitoring Implementation Guidelines

    International Nuclear Information System (INIS)

    E. Davis, R. Bickford

    2003-01-01

    Industry and EPRI experience at several plants has shown on-line monitoring to be very effective in identifying out-of-calibration instrument channels or indications of equipment-degradation problems. The EPRI implementation project for on-line monitoring has demonstrated the feasibility of on-line monitoring at several participating nuclear plants. The results have been very encouraging, and substantial progress is anticipated in the coming years

  16. Extracting dynamics from threshold-crossing interspike intervals: Possibilities and limitations

    DEFF Research Database (Denmark)

    Pavlov, A. N.; Sosnovtseva, O. V.; Mosekilde, Erik

    2000-01-01

    In this paper we estimate dynamical characteristics of chaotic attractors from sequences of threshold-crossing interspike intervals, and study how the choice of the threshold level (which sets the equation of a secant plane) influences the results of the numerical computations. Under quite genera...

  17. Model-based extraction of input and organ functions in dynamic scintigraphic imaging

    Czech Academy of Sciences Publication Activity Database

    Tichý, Ondřej; Šmídl, Václav; Šámal, M.

    2016-01-01

    Roč. 4, 3-4 (2016), s. 135-145 ISSN 2168-1171 R&D Projects: GA ČR GA13-29225S Institutional support: RVO:67985556 Keywords : blind source separation * convolution * dynamic medical imaging * compartment modelling Subject RIV: BB - Applied Statistics, Operational Research http://library.utia.cas.cz/separaty/2014/AS/tichy-0428540.pdf

  18. Tropical forest harvesting and taxation: a dynamic model of harvesting behavior under selective extraction systems

    Science.gov (United States)

    Robert F. Conrad; Malcolm Gillis; D. Evan Mercer

    2005-01-01

    A dynamic model of selective harvesting in multi-species,multi-age tropical forests is developed. Forests are predicted to exhibit different optimal harvesting profiles depending on the nature of their joint cost functions and own or cross-species stock effects. The model is applied to the controversy about incentives produced by various taxes. The impacts of specific...

  19. Extraction of Dynamic Features from Hand Drawn Data for the Identification of Children with Handwriting Difficulty

    Science.gov (United States)

    Khalid, Puspa Inayat; Yunus, Jasmy; Adnan, Robiah

    2010-01-01

    Studies have shown that differences between children with and without handwriting difficulties lie not only in the written product (static data) but also in dynamic data of handwriting process. Since writing system varies among countries and individuals, this study was conducted to determine the feasibility of using quantitative outcome measures…

  20. Extracting dynamics from threshold-crossing interspike intervals: possibilities and limitations

    DEFF Research Database (Denmark)

    Pavlov, A N; Sosnovtseva, Olga; Mosekilde, Erik

    2000-01-01

    In this paper we estimate dynamical characteristics of chaotic attractors from sequences of threshold-crossing interspike intervals, and study how the choice of the threshold level (which sets the equation of a secant plane) influences the results of the numerical computations. Under quite genera...

  1. Comparing the Hierarchy of Keywords in On-Line News Portals.

    Science.gov (United States)

    Tibély, Gergely; Sousa-Rodrigues, David; Pollner, Péter; Palla, Gergely

    2016-01-01

    Hierarchical organization is prevalent in networks representing a wide range of systems in nature and society. An important example is given by the tag hierarchies extracted from large on-line data repositories such as scientific publication archives, file sharing portals, blogs, on-line news portals, etc. The tagging of the stored objects with informative keywords in such repositories has become very common, and in most cases the tags on a given item are free words chosen by the authors independently. Therefore, the relations among keywords appearing in an on-line data repository are unknown in general. However, in most cases the topics and concepts described by these keywords are forming a latent hierarchy, with the more general topics and categories at the top, and more specialized ones at the bottom. There are several algorithms available for deducing this hierarchy from the statistical features of the keywords. In the present work we apply a recent, co-occurrence-based tag hierarchy extraction method to sets of keywords obtained from four different on-line news portals. The resulting hierarchies show substantial differences not just in the topics rendered as important (being at the top of the hierarchy) or of less interest (categorized low in the hierarchy), but also in the underlying network structure. This reveals discrepancies between the plausible keyword association frameworks in the studied news portals.

  2. Comparing the Hierarchy of Keywords in On-Line News Portals.

    Directory of Open Access Journals (Sweden)

    Gergely Tibély

    Full Text Available Hierarchical organization is prevalent in networks representing a wide range of systems in nature and society. An important example is given by the tag hierarchies extracted from large on-line data repositories such as scientific publication archives, file sharing portals, blogs, on-line news portals, etc. The tagging of the stored objects with informative keywords in such repositories has become very common, and in most cases the tags on a given item are free words chosen by the authors independently. Therefore, the relations among keywords appearing in an on-line data repository are unknown in general. However, in most cases the topics and concepts described by these keywords are forming a latent hierarchy, with the more general topics and categories at the top, and more specialized ones at the bottom. There are several algorithms available for deducing this hierarchy from the statistical features of the keywords. In the present work we apply a recent, co-occurrence-based tag hierarchy extraction method to sets of keywords obtained from four different on-line news portals. The resulting hierarchies show substantial differences not just in the topics rendered as important (being at the top of the hierarchy or of less interest (categorized low in the hierarchy, but also in the underlying network structure. This reveals discrepancies between the plausible keyword association frameworks in the studied news portals.

  3. On line systems of information acquisition

    International Nuclear Information System (INIS)

    Kucharek, P.; Toth, J.

    2004-01-01

    The modern methods of tracing the real state of working funds and the decisions made on the basis of the portfolio of factors, with the possibility of depicting the results of strategical decisions, enable the companies to compete in the hard environs of the global competition. Common platform providing the total information about dynamics of procedures and production goods in the real time is applied in many power plants of the SE, Plc. The software platform SYSTEM 1 is the subject to the constant development in accordance with the needs of modern management of working fond. The System 1(tm) release 5.0 is expected in the second quarter of 2004. New approach to application package according to users demands will provide higher comfort by using a product. New possibilities will be demonstrated on particular SE, Plc applications. Scenario of determination of potential breakdown of a machine - elements of a machine at the very beginning and the way of support decision on different levels of management. Operation, maintenance, optimization of production and the management of the whole company can decide on the basis of the knowledge and the factors provided in real time and fully by one environs directly on the manager's desk

  4. On-line determination of manganese in solid seafood samples by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Yebra, M.C.; Moreno-Cid, A.

    2003-01-01

    Manganese is extracted on-line from solid seafood samples by a simple continuous ultrasound-assisted extraction system (CUES). This system is connected to an on-line manifold, which permits the flow-injection flame atomic absorption spectrometric determination of manganese. Optimisation of the continuous leaching procedure is performed by an experimental design. The proposed method allows the determination of manganese with a relative standard deviation of 0.9% for a sample containing 23.4 μg g -1 manganese (dry mass). The detection limit is 0.4 μg g -1 (dry mass) for 30 mg of sample and the sample throughput is ca. 60 samples per hour. Accurate results are obtained by measuring TORT-1 certified reference material. The procedure is finally applied to mussel, tuna, sardine and clams samples

  5. Good control practices underlined by an on-line fuzzy control database

    Directory of Open Access Journals (Sweden)

    Alonso, M. V.

    1994-04-01

    Full Text Available In the olive oil trade, control systems that automate extraction processes, cutting production costs and increasing processing capacity without losing quality, are always desirable. The database structure of an on-line fuzzy control of centrifugation systems and the algorithms used to attain the best control conditions are analysed. Good control practices are suggested to obtain virgin olive oil of prime quality.

    In the olive oil trade, control systems that automate extraction processes, cutting production costs and increasing processing capacity without losing quality, are always desirable. The database structure of an on-line fuzzy control of centrifugation systems and the algorithms used to attain the best control conditions are analysed. Good control practices are suggested to obtain virgin olive oil of prime quality.

  6. On-Line Monitoring of Fermentation Processes by Near Infrared and Fluorescence Spectroscopy

    DEFF Research Database (Denmark)

    Svendsen, Carina

    Monitoring and control of fermentation processes is important to ensure high product yield, product quality and product consistency. More knowledge on on-line analytical techniques such as near infrared and fluorescence spectroscopy is desired in the fermentation industry to increase the efficiency...... of on-line monitoring systems. The primary aim of this thesis is to elucidate and explore the dynamics in fermentation processes by spectroscopy. Though a number of successful on-line lab-scale monitoring systems have been reported, it seems that several challenges are still met, which limits the number...... of full-scale systems implemented in industrial fermentation processes. This thesis seeks to achieve a better understanding of the techniques near infrared and fluorescence spectroscopy and thereby to solve some of the challenges that are encountered. The thesis shows the advantages of applying real...

  7. How do you assign persistent identifiers to extracts from large, complex, dynamic data sets that underpin scholarly publications?

    Science.gov (United States)

    Wyborn, Lesley; Car, Nicholas; Evans, Benjamin; Klump, Jens

    2016-04-01

    Persistent identifiers in the form of a Digital Object Identifier (DOI) are becoming more mainstream, assigned at both the collection and dataset level. For static datasets, this is a relatively straight-forward matter. However, many new data collections are dynamic, with new data being appended, models and derivative products being revised with new data, or the data itself revised as processing methods are improved. Further, because data collections are becoming accessible as services, researchers can log in and dynamically create user-defined subsets for specific research projects: they also can easily mix and match data from multiple collections, each of which can have a complex history. Inevitably extracts from such dynamic data sets underpin scholarly publications, and this presents new challenges. The National Computational Infrastructure (NCI) has been experiencing and making progress towards addressing these issues. The NCI is large node of the Research Data Services initiative (RDS) of the Australian Government's research infrastructure, which currently makes available over 10 PBytes of priority research collections, ranging from geosciences, geophysics, environment, and climate, through to astronomy, bioinformatics, and social sciences. Data are replicated to, or are produced at, NCI and then processed there to higher-level data products or directly analysed. Individual datasets range from multi-petabyte computational models and large volume raster arrays, down to gigabyte size, ultra-high resolution datasets. To facilitate access, maximise reuse and enable integration across the disciplines, datasets have been organized on a platform called the National Environmental Research Data Interoperability Platform (NERDIP). Combined, the NERDIP data collections form a rich and diverse asset for researchers: their co-location and standardization optimises the value of existing data, and forms a new resource to underpin data-intensive Science. New publication

  8. Wavelet analysis of molecular dynamics: Efficient extraction of time-frequency information in ultrafast optical processes

    International Nuclear Information System (INIS)

    Prior, Javier; Castro, Enrique; Chin, Alex W.; Almeida, Javier; Huelga, Susana F.; Plenio, Martin B.

    2013-01-01

    New experimental techniques based on nonlinear ultrafast spectroscopies have been developed over the last few years, and have been demonstrated to provide powerful probes of quantum dynamics in different types of molecular aggregates, including both natural and artificial light harvesting complexes. Fourier transform-based spectroscopies have been particularly successful, yet “complete” spectral information normally necessitates the loss of all information on the temporal sequence of events in a signal. This information though is particularly important in transient or multi-stage processes, in which the spectral decomposition of the data evolves in time. By going through several examples of ultrafast quantum dynamics, we demonstrate that the use of wavelets provide an efficient and accurate way to simultaneously acquire both temporal and frequency information about a signal, and argue that this greatly aids the elucidation and interpretation of physical process responsible for non-stationary spectroscopic features, such as those encountered in coherent excitonic energy transport

  9. Optimization of an on-line function generation

    CERN Document Server

    Versteele, C

    1977-01-01

    A particular example of process control is the analog function generator of the CERN proton synchrotron. For magnet field correction, some magnets have to follow reference currents synchronous with the pulses of the synchrotron. Depending on the dynamic behaviour of the magnet system to be controlled, the output current will show a somewhat distorted image of the reference current used as input. An on-line computer strategy has been designed to compensate the distortions: i.e. to adjust the input function at successive pulses in such a way that the output current follows the reference as closely as required. However, the identification of such a system is not carried out because it is difficult and singular in any case. Modifications cannot be computed directly, but will result from an iterative strategy: the closed-loop adaptive control is based on a maximization procedure, requiring little memory and no gradient information. The algorithm is a variant of the optimization method called extended sequential se...

  10. Perspective: Differential dynamic microscopy extracts multi-scale activity in complex fluids and biological systems

    Science.gov (United States)

    Cerbino, Roberto; Cicuta, Pietro

    2017-09-01

    Differential dynamic microscopy (DDM) is a technique that exploits optical microscopy to obtain local, multi-scale quantitative information about dynamic samples, in most cases without user intervention. It is proving extremely useful in understanding dynamics in liquid suspensions, soft materials, cells, and tissues. In DDM, image sequences are analyzed via a combination of image differences and spatial Fourier transforms to obtain information equivalent to that obtained by means of light scattering techniques. Compared to light scattering, DDM offers obvious advantages, principally (a) simplicity of the setup; (b) possibility of removing static contributions along the optical path; (c) power of simultaneous different microscopy contrast mechanisms; and (d) flexibility of choosing an analysis region, analogous to a scattering volume. For many questions, DDM has also advantages compared to segmentation/tracking approaches and to correlation techniques like particle image velocimetry. The very straightforward DDM approach, originally demonstrated with bright field microscopy of aqueous colloids, has lately been used to probe a variety of other complex fluids and biological systems with many different imaging methods, including dark-field, differential interference contrast, wide-field, light-sheet, and confocal microscopy. The number of adopting groups is rapidly increasing and so are the applications. Here, we briefly recall the working principles of DDM, we highlight its advantages and limitations, we outline recent experimental breakthroughs, and we provide a perspective on future challenges and directions. DDM can become a standard primary tool in every laboratory equipped with a microscope, at the very least as a first bias-free automated evaluation of the dynamics in a system.

  11. Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET.

    Science.gov (United States)

    Harms, Hendrik Johannes; Stubkjær Hansson, Nils Henrik; Tolbod, Lars Poulsen; Kim, Won Yong; Jakobsen, Steen; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiaer, Jørgen; Sörensen, Jens

    2016-09-01

    Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  12. Revegetation dynamics after 15 years of rewetting in two extracted peatlands in Sweden

    Directory of Open Access Journals (Sweden)

    S.A. Kozlov

    2016-02-01

    Full Text Available The restoration of extracted peatlands poses challenges with regard to their recolonisation by vegetation. The most significant problems are unstable water levels, destroyed propagule bank, and temperature fluctuations on bare peat surfaces. Rewetting is considered necessary for the re-establishment of peat-forming vegetation. Revegetation was investigated in a long-term field study at two rewetted extracted peatland sites in south-central Sweden, namely Västkärr (originally a lagg fen and Porla (originally a bog. Both sites were expanses of bare peat before rewetting. Rewetting procedures were applied in 1999 and strongly promoted plant colonisation. At Västkärr, colonisation started in the first year after rewetting, mostly by species that were not found during repeat vegetation surveys 15 years later. By 2014, Västkärr was a shallow lake surrounded by mesotrophic and eutrophic vegetation with species such as Carex rostrata, Lemna minor, Typha latifolia, Phalaris arundinacea and Phragmites australis. Revegetation of the Porla site was slower and started with Eriophorum vaginatum and Polytrichum spp. Sphagnum mosses appeared after six years and had established quite well after 13 years. A residual Sphagnum peat layer, inflowing surface water and groundwater provided spatially variable nutrient conditions. Sphagnum species and E. vaginatum established in nutrient-poor areas, while C. rostrata, P. australis and Eriophorum angustifolium colonised more nutrient-rich locations.

  13. Remote Automatic Material On-Line Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Magnuson, Erik

    2005-12-20

    Low cost NMR sensor for measuring moisture content of forest products. The Department of Energy (DOE) Industries of the Future (IOF) program seeks development and implementation of technologies that make industry more efficient--in particular, more energy-efficient. Quantum Magnetics, Inc. (QM), a wholly-owned subsidiary of GE Security, received an award under the program to investigate roles for low-cost Nuclear Magnetic Resonance (NMR) technology in furtherance of these goals. Most NMR systems are designed for high-resolution spectroscopy applications. These systems use intense magnetic fields produced by superconducting magnets that drive price and operating cost to levels beyond industry tolerance. At low magnetic fields, achievable at low cost, one loses the ability to obtain spectroscopic information. However, measuring the time constants associated with the NMR signal, called NMR relaxometry, gives indications of chemical and physical states of interest to process control and optimization. It was the purpose of this effort to investigate the technical and economic feasibility of using such low-field, low-cost NMR to monitor parameters enabling greater process efficiencies. The primary target industry identified in the Cooperative Development Agreement was the wood industry, where the moisture content of wood is a key process parameter from the time the cut tree enters a mill until the time it is delivered as pieces of lumber. Extracting the moisture is energy consuming, and improvements in drying efficiency stand to reduce costs and emissions substantially. QM designed and developed a new, low-cost NMR instrument suitable for inspecting lumber up to 3 inches by 12 inches in cross section, and other materials of similar size. Low cost is achieved via an inexpensive, permanent magnet and low-cost NMR spectrometer electronics. Laboratory testing demonstrated that the NMR system is capable of accurate ({+-} 0.5%) measurements of the moisture content of wood for

  14. Requirements for a Dynamic Solvent Extraction Module to Support Development of Advanced Technologies for the Recycle of Used Nuclear Fuel

    International Nuclear Information System (INIS)

    Law, Jack; Rutledge, Veronica; Pereira, Candido; Copple, Jackie; Frey, Kurt; Krebs, John; Maggos, Laura; Nichols, Kevin; Wardle, Kent; Sadasivan, Pratap; DeAlmieda, Valmor; Depaoli, David

    2011-01-01

    The Department of Energy's Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program has been established to create and deploy next generation, verified and validated nuclear energy modeling and simulation capabilities for the design, implementation, and operation of future nuclear energy systems to improve the U.S. energy security. As part of the NEAMS program, Integrated Performance and Safety Codes (IPSC's) are being produced to significantly advance the status of modeling and simulation of energy systems beyond what is currently available to the extent that the new codes be readily functional in the short term and extensible in the longer term. The four IPSC areas include Safeguards and Separations, Reactors, Fuels, and Waste Forms. As part of the Safeguards and Separations (SafeSeps) IPSC effort, interoperable process models are being developed that enable dynamic simulation of an advanced separations plant. A SafeSepss IPSC 'toolkit' is in development to enable the integration of separation process modules and safeguards tools into the design process by providing an environment to compose, verify and validate a simulation application to be used for analysis of various plant configurations and operating conditions. The modules of this toolkit will be implemented on a modern, expandable architecture with the flexibility to explore and evaluate a wide range of process options while preserving their stand-alone usability. Modules implemented at the plant-level will initially incorporate relatively simple representations for each process through a reduced modeling approach. Final versions will incorporate the capability to bridge to subscale models to provide required fidelity in chemical and physical processes. A dynamic solvent extraction model and its module implementation are needed to support the development of this integrated plant model. As a stand-alone application, it will also support solvent development of extraction flowsheets and integrated

  15. Requirements for a Dynamic Solvent Extraction Module to Support Development of Advanced Technologies for the Recycle of Used Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Jack Law; Veronica Rutledge; Candido Pereira; Jackie Copple; Kurt Frey; John Krebs; Laura Maggos; Kevin Nichols; Kent Wardle; Pratap Sadasivan; Valmor DeAlmieda; David Depaoli

    2011-06-01

    The Department of Energy's Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program has been established to create and deploy next generation, verified and validated nuclear energy modeling and simulation capabilities for the design, implementation, and operation of future nuclear energy systems to improve the U.S. energy security. As part of the NEAMS program, Integrated Performance and Safety Codes (IPSC's) are being produced to significantly advance the status of modeling and simulation of energy systems beyond what is currently available to the extent that the new codes be readily functional in the short term and extensible in the longer term. The four IPSC areas include Safeguards and Separations, Reactors, Fuels, and Waste Forms. As part of the Safeguards and Separations (SafeSeps) IPSC effort, interoperable process models are being developed that enable dynamic simulation of an advanced separations plant. A SafeSepss IPSC 'toolkit' is in development to enable the integration of separation process modules and safeguards tools into the design process by providing an environment to compose, verify and validate a simulation application to be used for analysis of various plant configurations and operating conditions. The modules of this toolkit will be implemented on a modern, expandable architecture with the flexibility to explore and evaluate a wide range of process options while preserving their stand-alone usability. Modules implemented at the plant-level will initially incorporate relatively simple representations for each process through a reduced modeling approach. Final versions will incorporate the capability to bridge to subscale models to provide required fidelity in chemical and physical processes. A dynamic solvent extraction model and its module implementation are needed to support the development of this integrated plant model. As a stand-alone application, it will also support solvent development of extraction flowsheets

  16. On-line stable isotope measurements during plant and soil gas exchange

    International Nuclear Information System (INIS)

    Yakir, D.

    2001-01-01

    Recent techniques for on-line stable isotope measurements during plant and soil exchange of CO 2 and/or water vapor are briefly reviewed. For CO 2 , these techniques provide means for on-line measurements of isotopic discrimination during CO 2 exchange by leaves in the laboratory and in the field, of isotopic discrimination during soil respiration and during soil-atmosphere CO 2 exchange, and of isotopic discrimination in O 2 during plant respiration. For water vapor, these techniques provide means to measure oxygen isotopic composition of water vapor during leaf transpiration and for the analysis of sub microliter condensed water vapor samples. Most of these techniques involve on-line sampling of CO 2 and water vapor from a dynamic, intact soil or plant system. In the laboratory, these systems also allow on-line isotopic analysis by continuous-flow isotope ratio mass spectrometry. The information obtained with these on-line techniques is becoming increasingly valuable, and often critical, for ecophysiologial research and in the study of biosphere-atmosphere interactions. (author)

  17. Contribution to the study of liquid-liquid extraction dynamics in the case of fast transfers. Extractions of uranium, plutonium and neptunium in a laboratory centrifugal extractor

    International Nuclear Information System (INIS)

    Bergeonneau, Philippe

    1978-01-01

    The liquid-liquid extraction (also named solvent-based extraction) is a very important technique for the reprocessing of irradiated nuclear fuels. This research thesis is based on the use of a laboratory centrifugal extractor which allows interesting conditions to be achieved: fast transfer due to an intense solution mixing, very short duration of contact between solutions. Thus, after a report of a bibliographical study on chemical mechanisms of extraction, on the composition of extracted species, on extraction kinetics, and on centrifugal extractors, this thesis reports the design, fabrication and use of a centrifugal extractor: presentation of fundamental principles, description and characteristics (materials, hydrodynamic operation test and problems, prototype). It reports studies of fast transfer kinetics: mathematical processing, result interpretation, results and discussions of extraction kinetics for nitric acid, uranium VI and IV, plutonium IV, neptunium IV, and comparison of the different extraction kinetics

  18. Algorithms for the on-line travelling salesman

    NARCIS (Netherlands)

    Ausiello, G.; Feuerstein, E.; Leonardi, S.; Stougie, L.; Talamo, M.

    1999-01-01

    In this paper the problem of efficiently serving a sequence of requests presented in an on-line fashion located at points of a metric space is considered. We call this problem the On-Line Travelling Salesman Problem (OLTSP). It has a variety of relevant applications in logistics and robotics. We

  19. On-Line Voltage Stability Assessment based on PMU Measurements

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Nielsen, Arne Hejde

    2009-01-01

    This paper presents a method for on-line monitoring of risk voltage collapse based on synchronised phasor measurement. As there is no room for intensive computation and analysis in real-time, the method is based on the combination of off-line computation and on-line monitoring, which are correlat...

  20. On-line and bulk analysis for the resource industries

    International Nuclear Information System (INIS)

    Lim, C.S.; Sowerby, B.D.; Tickner, J.R.; Madsen, I.C.

    2001-01-01

    Nuclear techniques are the basis of many CSIRO on-line and bulk analysis systems that are now widely used in the mineral and energy industries. The continuous analysis and rapid response of these systems have led to improved control of mining, processing and blending operations. This paper reviews recent developments in neutron, gamma-ray and X-ray techniques for on-line and bulk analysis by CSIRO Minerals including neutron techniques for the on-conveyor belt determination of the composition of cement raw meal, the on-line analysis of composition in pyrometallurgical applications, the on-conveyor belt determination of ash in coal, and the rapid and accurate determination of gold in bulk laboratory samples. The paper also discusses a new gamma-ray technique for the on-line determination of ash in coal and the application of X-ray diffraction techniques for the on-line determination of mineralogy in the cement industry

  1. Extracting quantum dynamics from genetic learning algorithms through principal control analysis

    International Nuclear Information System (INIS)

    White, J L; Pearson, B J; Bucksbaum, P H

    2004-01-01

    Genetic learning algorithms are widely used to control ultrafast optical pulse shapes for photo-induced quantum control of atoms and molecules. An unresolved issue is how to use the solutions found by these algorithms to learn about the system's quantum dynamics. We propose a simple method based on covariance analysis of the control space, which can reveal the degrees of freedom in the effective control Hamiltonian. We have applied this technique to stimulated Raman scattering in liquid methanol. A simple model of two-mode stimulated Raman scattering is consistent with the results. (letter to the editor)

  2. Sexual affordances, perceptual-motor invariance extraction and intentional nonlinear dynamics: sexually deviant and non-deviant patterns in male subjects.

    Science.gov (United States)

    Renaud, Patrice; Goyette, Mathieu; Chartier, Sylvain; Zhornitski, Simon; Trottier, Dominique; Rouleau, Joanne-L; Proulx, Jean; Fedoroff, Paul; Bradford, John-P; Dassylva, Benoit; Bouchard, Stephane

    2010-10-01

    Sexual arousal and gaze behavior dynamics are used to characterize deviant sexual interests in male subjects. Pedophile patients and non-deviant subjects are immersed with virtual characters depicting relevant sexual features. Gaze behavior dynamics as indexed from correlation dimensions (D2) appears to be fractal in nature and significantly different from colored noise (surrogate data tests and recurrence plot analyses were performed). This perceptual-motor fractal dynamics parallels sexual arousal and differs from pedophiles to non-deviant subjects when critical sexual information is processed. Results are interpreted in terms of sexual affordance, perceptual invariance extraction and intentional nonlinear dynamics.

  3. Extracting functional components of neural dynamics with Independent Component Analysis and inverse Current Source Density.

    Science.gov (United States)

    Lęski, Szymon; Kublik, Ewa; Swiejkowski, Daniel A; Wróbel, Andrzej; Wójcik, Daniel K

    2010-12-01

    Local field potentials have good temporal resolution but are blurred due to the slow spatial decay of the electric field. For simultaneous recordings on regular grids one can reconstruct efficiently the current sources (CSD) using the inverse Current Source Density method (iCSD). It is possible to decompose the resultant spatiotemporal information about the current dynamics into functional components using Independent Component Analysis (ICA). We show on test data modeling recordings of evoked potentials on a grid of 4 × 5 × 7 points that meaningful results are obtained with spatial ICA decomposition of reconstructed CSD. The components obtained through decomposition of CSD are better defined and allow easier physiological interpretation than the results of similar analysis of corresponding evoked potentials in the thalamus. We show that spatiotemporal ICA decompositions can perform better for certain types of sources but it does not seem to be the case for the experimental data studied. Having found the appropriate approach to decomposing neural dynamics into functional components we use the technique to study the somatosensory evoked potentials recorded on a grid spanning a large part of the forebrain. We discuss two example components associated with the first waves of activation of the somatosensory thalamus. We show that the proposed method brings up new, more detailed information on the time and spatial location of specific activity conveyed through various parts of the somatosensory thalamus in the rat.

  4. A molecular dynamics study of components of the ginger (Zingiber officinale) extract inside human acetylcholinesterase: implications for Alzheimer disease.

    Science.gov (United States)

    Cuya, Teobaldo; Baptista, Leonardo; Celmar Costa França, Tanos

    2017-11-23

    Components of ginger (Zingiber officinale) extracts have been described as potential new drug candidates against Alzheimer disease (AD), able to interact with several molecular targets related to the AD treatment. However, there are very few theoretical studies in the literature on the possible mechanisms of action by which these compounds can work as potential anti-AD drugs. For this reason, we performed here docking, molecular dynamic simulations and mmpbsa calculations on four components of ginger extracts former reported as active inhibitors of human acetylcholinesterase (HssAChE), and compared our results to the known HssAChE inhibitor and commercial drug in use against AD, donepezil (DNP). Our findings points to two among the compounds studied: (E)-1,7-bis(4-hydroxy-3-methoxyphenyl)hept-4-en-3-on and 1-(3,4-dihydroxy-5-methoxyphenyl)-7-(4-hydroxy-3- ethoxyphenyl) heptane-3,5-diyl diacetate, as promising new HssAChE inhibitors that could be as effective as DNP. We also mapped the binding of the studied compounds in the different binding pockets inside HssAChE and established the preferred interactions to be favored in the design of new and more efficient inhibitors.

  5. Observing dynamics of chromatin fibers in Xenopus egg extracts by single DNA manipulation using a transverse magnetic tweezer setup

    Science.gov (United States)

    Yan, Jie; Skoko, Dunja; Marko, John; Maresca, Tom; Heald, Rebecca

    2005-03-01

    We have studied assembly of chromatin on single DNAs using Xenopus egg extracts and a specially designed magnetic tweezer setup which generates controlled force in the focal plane of the objective, allowing us to visualize and measure DNA extension under a wide range of constant tensions. We found, in the absence of ATP, interphase extracts assembled nucleosomes against DNA tensions of up to 3.5 piconewtons (pN). We observed force-induced disassembly and opening-closing fluctuations indicating our experiments were in mechano-chemical equilibrium. We found that the ATP-depleted reaction can do mechanical work of 27 kcal/mol per nucleosome, providing a measurement of the free energy difference between core histone octamers on and off DNA. Addition of ATP leads to highly dynamic behavior: time courses show processive runs of assembly and disassembly of not observed in the -ATP case, with forces of 2 pN leading to nearly complete fiber disassembly. Our study shows that ATP hydrolysis plays a major role in nucleosome rearrangement and removal, and suggests that chromatin in vivo may be subject to continual assembly and disassembly.

  6. Rapid determination of 18 glucocorticoids in serum using reusable on-line SPE polymeric monolithic column coupled with LC-quadrupole/orbitrap high-resolution mass spectrometer.

    Science.gov (United States)

    Li, Hui; Ai, Lianfeng; Fan, Sufang; Wang, Yan; Sun, Dianxing

    2017-10-15

    A simple, rapid and sensitive method for the simultaneous determination of 18 glucocorticoids in serum was developed by coupling on-line solid-phase extraction (SPE) polymeric monolithic column to a liquid chromatography-quadrupole/orbitrap high-resolution mass spectrometer. A simple poly(ethylene glycol dimethacrylate) monolith column (10mm×2.1mm i.d.) was fabricated, and the morphology, surface area and extraction performance of the monolithic column were characterized. Serum samples were extracted by acetonitrile (ACN). Then, online SPE was achieved on the synthesized monolithic column using a 10mmol/L ammonium acetate solution as the loading solvent. After the transfer from the monolith into analytical column (Capcell Pak ADME column) using ACN, the adsorbed analytes were separated on the analytical column and detected with a high-resolution hybrid quadrupole/orbitrap mass spectrometer with full scan/ddMS 2 scan mode Under optimized conditions, the method was linear with target linear correlation coefficient (R 2 ) higher than 0.995. Detection limits were in range of 0.1-0.6ng/mL, and the quantification limits were 0.3-1.5ng/mL. The recovery was between 71.9% and 89.2% in three spike levels with precision (n=5) of 5.40-12.1%. The serum sample was directly analyzed after a simple extraction procedure, and the on-line SPE and determination were achieved within only 16min. The method was used to analyze the dynamic contents variation of cortisone and hydrocortisone in serum before and after the surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Simulation of geothermal water extraction in heterogeneous reservoirs using dynamic unstructured mesh optimisation

    Science.gov (United States)

    Salinas, P.; Pavlidis, D.; Jacquemyn, C.; Lei, Q.; Xie, Z.; Pain, C.; Jackson, M.

    2017-12-01

    It is well known that the pressure gradient into a production well increases with decreasing distance to the well. To properly capture the local pressure drawdown into the well a high grid or mesh resolution is required; moreover, the location of the well must be captured accurately. In conventional simulation models, the user must interact with the model to modify grid resolution around wells of interest, and the well location is approximated on a grid defined early in the modelling process.We report a new approach for improved simulation of near wellbore flow in reservoir scale models through the use of dynamic mesh optimisation and the recently presented double control volume finite element method. Time is discretized using an adaptive, implicit approach. Heterogeneous geologic features are represented as volumes bounded by surfaces. Within these volumes, termed geologic domains, the material properties are constant. Up-, cross- or down-scaling of material properties during dynamic mesh optimization is not required, as the properties are uniform within each geologic domain. A given model typically contains numerous such geologic domains. Wells are implicitly coupled with the domain, and the fluid flows is modelled inside the wells. The method is novel for two reasons. First, a fully unstructured tetrahedral mesh is used to discretize space, and the spatial location of the well is specified via a line vector, ensuring its location even if the mesh is modified during the simulation. The well location is therefore accurately captured, the approach allows complex well trajectories and wells with many laterals to be modelled. Second, computational efficiency is increased by use of dynamic mesh optimization, in which an unstructured mesh adapts in space and time to key solution fields (preserving the geometry of the geologic domains), such as pressure, velocity or temperature, this also increases the quality of the solutions by placing higher resolution where required

  8. Extracting a respiratory signal from raw dynamic PET data that contain tracer kinetics.

    Science.gov (United States)

    Schleyer, P J; Thielemans, K; Marsden, P K

    2014-08-07

    Data driven gating (DDG) methods provide an alternative to hardware based respiratory gating for PET imaging. Several existing DDG approaches obtain a respiratory signal by observing the change in PET-counts within specific regions of acquired PET data. Currently, these methods do not allow for tracer kinetics which can interfere with the respiratory signal and introduce error. In this work, we produced a DDG method for dynamic PET studies that exhibit tracer kinetics. Our method is based on an existing approach that uses frequency-domain analysis to locate regions within raw PET data that are subject to respiratory motion. In the new approach, an optimised non-stationary short-time Fourier transform was used to create a time-varying 4D map of motion affected regions. Additional processing was required to ensure that the relationship between the sign of the respiratory signal and the physical direction of movement remained consistent for each temporal segment of the 4D map. The change in PET-counts within the 4D map during the PET acquisition was then used to generate a respiratory curve. Using 26 min dynamic cardiac NH3 PET acquisitions which included a hardware derived respiratory measurement, we show that tracer kinetics can severely degrade the respiratory signal generated by the original DDG method. In some cases, the transition of tracer from the liver to the lungs caused the respiratory signal to invert. The new approach successfully compensated for tracer kinetics and improved the correlation between the data-driven and hardware based signals. On average, good correlation was maintained throughout the PET acquisitions.

  9. Extracting a respiratory signal from raw dynamic PET data that contain tracer kinetics

    International Nuclear Information System (INIS)

    Schleyer, P J; Thielemans, K; Marsden, P K

    2014-01-01

    Data driven gating (DDG) methods provide an alternative to hardware based respiratory gating for PET imaging. Several existing DDG approaches obtain a respiratory signal by observing the change in PET-counts within specific regions of acquired PET data. Currently, these methods do not allow for tracer kinetics which can interfere with the respiratory signal and introduce error. In this work, we produced a DDG method for dynamic PET studies that exhibit tracer kinetics. Our method is based on an existing approach that uses frequency-domain analysis to locate regions within raw PET data that are subject to respiratory motion. In the new approach, an optimised non-stationary short-time Fourier transform was used to create a time-varying 4D map of motion affected regions. Additional processing was required to ensure that the relationship between the sign of the respiratory signal and the physical direction of movement remained consistent for each temporal segment of the 4D map. The change in PET-counts within the 4D map during the PET acquisition was then used to generate a respiratory curve. Using 26 min dynamic cardiac NH 3 PET acquisitions which included a hardware derived respiratory measurement, we show that tracer kinetics can severely degrade the respiratory signal generated by the original DDG method. In some cases, the transition of tracer from the liver to the lungs caused the respiratory signal to invert. The new approach successfully compensated for tracer kinetics and improved the correlation between the data-driven and hardware based signals. On average, good correlation was maintained throughout the PET acquisitions. (paper)

  10. Extracting a kinetic relation from the dynamics of a bistable chain

    International Nuclear Information System (INIS)

    Zhao, Qingze; Purohit, Prashant K

    2014-01-01

    We integrate Newton's second law for a chain of masses and bistable springs with a spinodal region with the goal of extracting a kinetic relation for propagating phase boundaries. Our numerical experiments correspond to the impact on a bar made of phase changing material. By reading off the spring extensions ahead and behind the phase boundaries in our numerical experiments, we compute a driving force and plot it as a function of the phase boundary velocity to get a kinetic relation. We then show that this kinetic relation results in solutions to Riemann problems in continuum bars that agree with the corresponding numerical experiments on the discrete mass–spring chain. We also integrate Langevin's equations of motion for the same chain of masses and springs to account for the presence of a heat bath at a fixed temperature. We find that the xt-plane looks similar to the purely mechanical numerical experiments at low temperatures but at high temperatures there is an increased incidence of random nucleation events. Using results from both impact and Riemann problems, we show that the kinetic relation is a function of the bath temperature. (paper)

  11. Extracting Usage Patterns and the Analysis of Tag Connection Dynamics within Collaborative Tagging Systems

    Directory of Open Access Journals (Sweden)

    Daniel MICAN

    2013-01-01

    Full Text Available Collaborative tagging has become a very popular way of annotation, thanks to the fact that any entity may be labeled by any individual based on his own reason. In this paper we present the results of the case study carried out on the basis of data gathered at different time intervals from the social tagging system developed and implemented on Întelepciune.ro. Analyzing collective data referring to the way in which community members associate different tags, we have observed that between tags, links are formed which become increasingly stable with the passing of time. Following the application of methodology specific to network analysis, we have managed to extract information referring to tag popularity, their influence within the network and the degree to which a tag depends upon another. As such, we have succeeded in determining different semantic structures within the collective tagging system and see their evolution at different stages in time. Furthermore, we have pictured the way in which tag rec-ommendations can be executed and that they can be integrated within recommendation sys-tems. Thus, we will be able to identify experts and trustworthy content based on different cat-egories of interest.

  12. Human interface for personal information systems. On-line handwriting recognition; Pasonaru joho kiki ni okeru human interface. On-line tegaki ninshiki

    Energy Technology Data Exchange (ETDEWEB)

    Morita, T. [Sharp Corp., Osaka (Japan)

    1996-01-05

    Most of information devices used in the business field use keyboards for the inputting measure, but keyboards are rather awkward for personal use. In contrast to this, the pen input method which everybody can use easily is a product of the latest development. In this articles, on-line handwritten letter recognition is roughly explained which is the basic technique of pen input. Pen input has a demerit that its letter inputting speed is slow, but has much more merits that Chinese ideographs can be directly input, figures, handwritten memoranda, etc. are treated likewise, the device itself can be made compact and no noise is made. The on-line letter recognition methods now used practically can be roughly divided into the pattern matching method and the basic stroke method. Each of them has its own merits and demerits. For the current on-line handwritten letter recognition, the condition is necessary to handwritten a letter in the square style (kaisho) and carefully within the framework for letter entry upon writing, and for this arrangement, input is performed through the work processes of pretreatment/feature extraction, stroke recognition, letter comparison, detail discrimination, and after-treatment. 3 refs., 7 figs.

  13. Understanding on-line community: the affordances of virtual space

    Directory of Open Access Journals (Sweden)

    Karen Ruhleder

    2002-01-01

    Full Text Available Increasing numbers of on-line venues for learning are emerging as virtual communities become more accessible and commonplace. This paper looks at one particular virtual community, an on-line degree programme at the University of Illinois, Urbana-Champaign, which offers an M.S. in Library and Information Science (called LEEP. It draws on a framework presented by Mynatt, et al. (1998, which provides a lens for talking about on-line community as a set of affordances. This framework is applied to illustrate the interactions, artefacts, and expectations that shape this community.

  14. An Approach to On-line Risk Assessment in NPP

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; O'Brien, J.

    1996-01-01

    Probabilistic Risk Assessment (PRA) can provide safety status information for a plant during different configurations; additional effort is needed to do this in real time for on-line operation. This paper describes an approach to use PRA to achieve these goals. A Risk Assessment On-Line (RAOL) application was developed to monitor maintenance (on-line and planned) activities. RAOL is based on the results from a full-scope PRA, engineering/operational judgment and incorporates a user friendly program interface approach. Results from RAOL can be used by planners or operations to effectively manage the level of risk by controlling the actual plant configuration. (author)

  15. On-line spectroscopy with thermal atomic beams

    International Nuclear Information System (INIS)

    Thibault, C.; Guimbal, P.; Klapisch, R.; Saint Simon, M. de; Serre, J.M.; Touchard, F.; Duong, H.T.; Jacquinot, P.; Juncar, P.

    1981-01-01

    On-line high resolution laser spectroscopy experiments have been performed in which the light from a cw tunable dye laser interacts at right angles with a thermal atomic beam. sup(76-98)Rb, sup(118-145)Cs and sup(208-213)Fr have been studied using the ionic beam delivered by the ISOLDE on-line mass separator at CERN while sup(20-31)Na and sup(38-47)K have been studied by setting the apparaturs directly on-line with the PS 20 GeV proton beam. The principle of the method is briefly explained and some results concerning nuclear structure are given. (orig.)

  16. Comparison of On-Line Maintenance Support Tools

    International Nuclear Information System (INIS)

    Simic, Z.; Follen, S. M.; Mikulicic, V.

    1998-01-01

    Modeling approach to on-line risk monitoring is today in a rapid developing phase. For that reason number of different solutions are available. This paper will attempt to present existing approaches to address on-line risk modeling problem Starting with description of on-line risk monitoring issues in general, then following by presentation of existing software tools (EPRI's Safety Monitor, Equipment Out of Service Monitor, and ORAM-SENTINEL) the current state of the art in this area will be demonstrated. Finally, conclusions and ideas will be outlined. (author)

  17. Emission enhancement, light extraction and carrier dynamics in InGaAs/GaAs nanowire arrays

    Science.gov (United States)

    Kivisaari, Pyry; Chen, Yang; Anttu, Nicklas

    2018-03-01

    Nanowires (NWs) have the potential for a wide range of new optoelectronic applications. For example, light-emitting diodes that span over the whole visible spectrum are currently being developed from NWs to overcome the well known green gap problem. However, due to their small size, NW devices exhibit special properties that complicate their analysis, characterization, and further development. In this paper, we develop a full optoelectronic simulation tool for NW array light emitters accounting for carrier transport and wave-optical emission enhancement (EE), and we use the model to simulate InGaAs/GaAs NW array light emitters with different geometries and temperatures. Our results show that NW arrays emit light preferentially to certain angles depending on the NW diameter and temperature, encouraging temperature- and angle-resolved measurements of NW array light emission. On the other hand, based on our results both the EE and light extraction efficiency can easily change by at least a factor of two between room temperature and 77 K, complicating the characterization of NW light emitters if conventional methods are used. Finally, simulations accounting for surface recombination emphasize its major effect on the device performance. For example, a surface recombination velocity of 104 cm s-1 reported earlier for bare InGaAs surfaces results in internal quantum efficiencies less than 30% for small-diameter NWs even at the temperature of 30 K. This highlights that core-shell structures or high-quality passivation techniques are eventually needed to achieve efficient NW-based light emitters.

  18. Fundamental Drop Dynamics and Mass Transfer Experiments to Support Solvent Extraction Modeling Efforts

    International Nuclear Information System (INIS)

    Christensen, Kristi; Rutledge, Veronica; Garn, Troy

    2011-01-01

    In support of the Nuclear Energy Advanced Modeling Simulation Safeguards and Separations (NEAMS SafeSep) program, the Idaho National Laboratory (INL) worked in collaboration with Los Alamos National Laboratory (LANL) to further a modeling effort designed to predict mass transfer behavior for selected metal species between individual dispersed drops and a continuous phase in a two phase liquid-liquid extraction (LLE) system. The purpose of the model is to understand the fundamental processes of mass transfer that occur at the drop interface. This fundamental understanding can be extended to support modeling of larger LLE equipment such as mixer settlers, pulse columns, and centrifugal contactors. The work performed at the INL involved gathering the necessary experimental data to support the modeling effort. A custom experimental apparatus was designed and built for performing drop contact experiments to measure mass transfer coefficients as a function of contact time. A high speed digital camera was used in conjunction with the apparatus to measure size, shape, and velocity of the drops. In addition to drop data, the physical properties of the experimental fluids were measured to be used as input data for the model. Physical properties measurements included density, viscosity, surface tension and interfacial tension. Additionally, self diffusion coefficients for the selected metal species in each experimental solution were measured, and the distribution coefficient for the metal partitioning between phases was determined. At the completion of this work, the INL has determined the mass transfer coefficient and a velocity profile for drops rising by buoyancy through a continuous medium under a specific set of experimental conditions. Additionally, a complete set of experimentally determined fluid properties has been obtained. All data will be provided to LANL to support the modeling effort.

  19. Intelligent on-line fault tolerant control for unanticipated catastrophic failures.

    Science.gov (United States)

    Yen, Gary G; Ho, Liang-Wei

    2004-10-01

    As dynamic systems become increasingly complex, experience rapidly changing environments, and encounter a greater variety of unexpected component failures, solving the control problems of such systems is a grand challenge for control engineers. Traditional control design techniques are not adequate to cope with these systems, which may suffer from unanticipated dynamic failures. In this research work, we investigate the on-line fault tolerant control problem and propose an intelligent on-line control strategy to handle the desired trajectories tracking problem for systems suffering from various unanticipated catastrophic faults. Through theoretical analysis, the sufficient condition of system stability has been derived and two different on-line control laws have been developed. The approach of the proposed intelligent control strategy is to continuously monitor the system performance and identify what the system's current state is by using a fault detection method based upon our best knowledge of the nominal system and nominal controller. Once a fault is detected, the proposed intelligent controller will adjust its control signal to compensate for the unknown system failure dynamics by using an artificial neural network as an on-line estimator to approximate the unexpected and unknown failure dynamics. The first control law is derived directly from the Lyapunov stability theory, while the second control law is derived based upon the discrete-time sliding mode control technique. Both control laws have been implemented in a variety of failure scenarios to validate the proposed intelligent control scheme. The simulation results, including a three-tank benchmark problem, comply with theoretical analysis and demonstrate a significant improvement in trajectory following performance based upon the proposed intelligent control strategy.

  20. The development of the microcomputer controlling system for micro uranium on-line analyser

    CERN Document Server

    Ye Guo Qiang

    2002-01-01

    The author presents the microcomputer controlling system for micro uranium on-line analyser under Windows 3.2 system (Chinese). The user program is designed with Visual Basic 4.0, the program of controlling the hardware interface with Windows Dynamic Linking Library (DLL) which is programmed by Borland C sup + sup + 4.5, and the date processing is with Access 2.0 database

  1. On-line methanol sensor system development for recombinant ...

    African Journals Online (AJOL)

    On-line methanol sensor system development for recombinant human serum ... of the methanol sensor system was done in a medium environment with yeast cells ... induction at a low temperature and a pH where protease does not function.

  2. On-line control systems in power plants

    International Nuclear Information System (INIS)

    Freymeyer, P.

    1981-01-01

    This report is a review of on-line control systems as a complex system connected with all problems like, development, planning, degree of automation, economics, service, quality and documentation. (orig.) [de

  3. Why do People Stop Playing On-Line Games?

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    2012-01-01

    The recent initial public offering of shares of Zynga, probably the most important on-line game provider, drew interest of potential investors but also of general public to their business model. What the most interested people learned so far is that if Zynga had not changed their accounting...... practice, they would be in red numbers for several months already. This is most likely caused by people stopping to play their games. This paper provides an estimate of what proportion of people, who played on-line games, already stopped playing them. Additionally, it analyzed the reasons why people...... stopped playing on-line games. It also compares Facebook and other on-line games....

  4. A signal-flow-graph approach to on-line gradient calculation.

    Science.gov (United States)

    Campolucci, P; Uncini, A; Piazza, F

    2000-08-01

    A large class of nonlinear dynamic adaptive systems such as dynamic recurrent neural networks can be effectively represented by signal flow graphs (SFGs). By this method, complex systems are described as a general connection of many simple components, each of them implementing a simple one-input, one-output transformation, as in an electrical circuit. Even if graph representations are popular in the neural network community, they are often used for qualitative description rather than for rigorous representation and computational purposes. In this article, a method for both on-line and batch-backward gradient computation of a system output or cost function with respect to system parameters is derived by the SFG representation theory and its known properties. The system can be any causal, in general nonlinear and time-variant, dynamic system represented by an SFG, in particular any feedforward, time-delay, or recurrent neural network. In this work, we use discrete-time notation, but the same theory holds for the continuous-time case. The gradient is obtained in a straightforward way by the analysis of two SFGs, the original one and its adjoint (obtained from the first by simple transformations), without the complex chain rule expansions of derivatives usually employed. This method can be used for sensitivity analysis and for learning both off-line and on-line. On-line learning is particularly important since it is required by many real applications, such as digital signal processing, system identification and control, channel equalization, and predistortion.

  5. The Daresbury On-Line Isotope Separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described

  6. The Daresbury on-line isotope separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described. (orig.)

  7. On-line mixture-based alternative to logistic regression

    Czech Academy of Sciences Publication Activity Database

    Nagy, Ivan; Suzdaleva, Evgenia

    2016-01-01

    Roč. 26, č. 5 (2016), s. 417-437 ISSN 1210-0552 R&D Projects: GA ČR GA15-03564S Institutional support: RVO:67985556 Keywords : on-line modeling * on-line logistic regression * recursive mixture estimation * data dependent pointer Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.394, year: 2016 http://library.utia.cas.cz/separaty/2016/ZS/suzdaleva-0464463.pdf

  8. Unattended reaction monitoring using an automated microfluidic sampler and on-line liquid chromatography.

    Science.gov (United States)

    Patel, Darshan C; Lyu, Yaqi Fara; Gandarilla, Jorge; Doherty, Steve

    2018-04-03

    In-process sampling and analysis is an important aspect of monitoring kinetic profiles and impurity formation or rejection, both in development and during commercial manufacturing. In pharmaceutical process development, the technology of choice for a substantial portion of this analysis is high-performance liquid chromatography (HPLC). Traditionally, the sample extraction and preparation for reaction characterization have been performed manually. This can be time consuming, laborious, and impractical for long processes. Depending on the complexity of the sample preparation, there can be variability introduced by different analysts, and in some cases, the integrity of the sample can be compromised during handling. While there are commercial instruments available for on-line monitoring with HPLC, they lack capabilities in many key areas. Some do not provide integration of the sampling and analysis, while others afford limited flexibility in sample preparation. The current offerings provide a limited number of unit operations available for sample processing and no option for workflow customizability. This work describes development of a microfluidic automated program (MAP) which fully automates the sample extraction, manipulation, and on-line LC analysis. The flexible system is controlled using an intuitive Microsoft Excel based user interface. The autonomous system is capable of unattended reaction monitoring that allows flexible unit operations and workflow customization to enable complex operations and on-line sample preparation. The automated system is shown to offer advantages over manual approaches in key areas while providing consistent and reproducible in-process data. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Determination of antibiotic compounds in water by on-line SPE-LC/MSD.

    Science.gov (United States)

    Choi, Keun-Joo; Kim, Sang-Goo; Kim, Chang-won; Kim, Seung-Hyun

    2007-01-01

    This study attempts to provide an improved approach for the analysis of antibiotics, which normally exist at low concentration in complex matrices such as receiving streams of wastewater treatment plant discharge. The analytical method developed in this study combines an existing pretreatment technique of solid-phase extraction (SPE) with liquid chromatography mass spectrometry (LC/MSD) through on-line connection. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 ml water samples, recoveries were between 74.3% and 116.5% and average LOQ was 0.11 microg l(-1) for the sulfonamide antibiotics (SA) and 0.09 microg l(-1) for the tetracycline antibiotics (TA). Application of the developed method for the analysis of fourteen antibiotics revealed that several antibiotics were detected at concentrations above the LOQ in ARW. Treated and untreated sewage and agricultural wastewater were mostly responsible for the antibiotics contamination of the river. Antibiotics were detected at much higher concentrations in the agricultural wastewater sample than in the sewage sample, implying substantial use of antibiotics in the agricultural industry. Wastewater treatment was generally effective in separation of the antibiotics tested in this study. The extent of the treatment depended on the type of antibiotics. Hydrophobic antibiotics were more effectively separated from the solution than hydrophilic antibiotics.

  10. Dynamic programming re-ranking for PPI interactor and pair extraction in full-text articles

    Science.gov (United States)

    2011-01-01

    Background Experimentally verified protein-protein interactions (PPIs) cannot be easily retrieved by researchers unless they are stored in PPI databases. The curation of such databases can be facilitated by employing text-mining systems to identify genes which play the interactor role in PPIs and to map these genes to unique database identifiers (interactor normalization task or INT) and then to return a list of interaction pairs for each article (interaction pair task or IPT). These two tasks are evaluated in terms of the area under curve of the interpolated precision/recall (AUC iP/R) score because the order of identifiers in the output list is important for ease of curation. Results Our INT system developed for the BioCreAtIvE II.5 INT challenge achieved a promising AUC iP/R of 43.5% by using a support vector machine (SVM)-based ranking procedure. Using our new re-ranking algorithm, we have been able to improve system performance (AUC iP/R) by 1.84%. Our experimental results also show that with the re-ranked INT results, our unsupervised IPT system can achieve a competitive AUC iP/R of 23.86%, which outperforms the best BC II.5 INT system by 1.64%. Compared to using only SVM ranked INT results, using re-ranked INT results boosts AUC iP/R by 7.84%. Statistical significance t-test results show that our INT/IPT system with re-ranking outperforms that without re-ranking by a statistically significant difference. Conclusions In this paper, we present a new re-ranking algorithm that considers co-occurrence among identifiers in an article to improve INT and IPT ranking results. Combining the re-ranked INT results with an unsupervised approach to find associations among interactors, the proposed method can boost the IPT performance. We also implement score computation using dynamic programming, which is faster and more efficient than traditional approaches. PMID:21342534

  11. The optimization of essential oils supercritical CO2 extraction from Lavandula hybrida through static-dynamic steps procedure and semi-continuous technique using response surface method

    Science.gov (United States)

    Kamali, Hossein; Aminimoghadamfarouj, Noushin; Golmakani, Ebrahim; Nematollahi, Alireza

    2015-01-01

    Aim: The aim of this study was to examine and evaluate crucial variables in essential oils extraction process from Lavandula hybrida through static-dynamic and semi-continuous techniques using response surface method. Materials and Methods: Essential oil components were extracted from Lavandula hybrida (Lavandin) flowers using supercritical carbon dioxide via static-dynamic steps (SDS) procedure, and semi-continuous (SC) technique. Results: Using response surface method the optimum extraction yield (4.768%) was obtained via SDS at 108.7 bar, 48.5°C, 120 min (static: 8×15), 24 min (dynamic: 8×3 min) in contrast to the 4.620% extraction yield for the SC at 111.6 bar, 49.2°C, 14 min (static), 121.1 min (dynamic). Conclusion: The results indicated that a substantial reduction (81.56%) solvent usage (kg CO2/g oil) is observed in the SDS method versus the conventional SC method. PMID:25598636

  12. Volume overload cleanup: An approach for on-line SPE-GC, GPC-GC, and GPC-SPE-GC

    NARCIS (Netherlands)

    Kerkdijk, H.; Mol, H.G.J.; Nagel, B. van der

    2007-01-01

    A new concept for cleanup, based on volume overloading of the cleanup column, has been developed for on-line coupling of gel permeation chromatography (GPC), solid-phase extraction (SPE), or both, to gas chromatography (GC). The principle is outlined and the applicability demonstrated by the

  13. On-Line/At-Line Technetium Monitor Using Scintillating Ion Exchange Resins for the Savannah River Site

    International Nuclear Information System (INIS)

    Wach, S.T.

    2000-01-01

    The results of this study indicate that the combination of extraction chromatography and on-line flow-cell scintillation counting can exceed a 99Tc detection limit of 0.005 Ci/mL in the presence of 90Sr, 137Cs, and 239Pu in less than an 18 minute analysis time

  14. Process Analytical Technology and On-Line Spectroscopic Measurements of Chemical Meat Quality

    DEFF Research Database (Denmark)

    Sørensen, Klavs Martin

    This thesis deals with process analytical technology and how it can be implemented in the meat industry through on-line grading of chemical meat quality. The focus will be on two applications, namely the rapid quality control of fat quality and the development of a method for on-line detection...... of nano-molar quantification in few seconds, in addition to an accelerated extraction-free GC-MS method that through automation can deliver results much faster than other similar methods. The implementation of these high tech methods will provide the meat industry with a leading edge not only with product...... of boar taint. The chemical makeup of fat has a large effect on meat cut quality. Fat quality has traditionally been determined by methylation of a tissue sample followed by chromatography on a GC-MS system, elucidating the composition of the individual fatty acids. As this procedure typically takes far...

  15. On-line monitoring of fluid bed granulation by photometric imaging.

    Science.gov (United States)

    Soppela, Ira; Antikainen, Osmo; Sandler, Niklas; Yliruusi, Jouko

    2014-11-01

    This paper introduces and discusses a photometric surface imaging approach for on-line monitoring of fluid bed granulation. Five granule batches consisting of paracetamol and varying amounts of lactose and microcrystalline cellulose were manufactured with an instrumented fluid bed granulator. Photometric images and NIR spectra were continuously captured on-line and particle size information was extracted from them. Also key process parameters were recorded. The images provided direct real-time information on the growth, attrition and packing behaviour of the batches. Moreover, decreasing image brightness in the drying phase was found to indicate granule drying. The changes observed in the image data were also linked to the moisture and temperature profiles of the processes. Combined with complementary process analytical tools, photometric imaging opens up possibilities for improved real-time evaluation fluid bed granulation. Furthermore, images can give valuable insight into the behaviour of excipients or formulations during product development. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. On-line maintenance PSA support at NPP Krsko

    International Nuclear Information System (INIS)

    Prosen, R.; Vrbanic, I.; Kastelan, M.

    2000-01-01

    In 1997 Krsko NPP initiated the on-line maintenance (OLM) practice. On-line maintenance constitutes of corrective activities, preventive activities, surveillance activities, tests and inspections, as well as calibrations and modifications, taking place during the normal power operations. The on-line maintenance is a multidisciplinary process consisting of activity specification, planning, and preparation and performing of the OLM activity of interest. The primary role of the PSA group is to assess from the r isk perspective , using the plant-specific NEK PSA model, system unavailability and the impact to the plant operational risk. The intent is to support planning of the on-line maintenance activities from the risk perspective. The risk evaluation of the OLM activities is based on the probability of core damage evaluation for the defined discrete plant configuration states, determined by the OLM activities. Within this application, the optimized, plant-specific PSA model is used on Risk Spectrum platform. To perform the risk assessment of the on-line maintenance activities, first the systems to be affected are defined based on the planned OLM activities. The next important step is the assessment of the planned work schedule. To define the final schedule, the co-ordination and optimizing the planned OLM activities needs activation of all participating departments, supported also from PSA group. The P3 (i.e. Primavera) planning tool system windows are defined for different systems and groups of systems, and the activities are sorted in particular weeks according to these windows. (author)

  17. OLDASS: On-line data acquisition system at SF cyclotron

    International Nuclear Information System (INIS)

    Omata, Kazuo; Yasue, Masaharu; Hamagaki, Hideki

    1982-01-01

    The on-line data acquisition system in the Institute for Nuclear Study, the University of Tokyo, is composed of 2 systems of Fujitsu mini-computer PFU-400 for data processing at the high energy synchrotron and one system of that computer for low energy cyclotron as terminals, the host computer being M 180 II AD of the same company. This system has been developed to have the features of being the on-line system capable of following the improvement of host computer performance, being capable of developing the on-line programmes of other experimenting groups in parallel with batch jobs or the operation of the on-line system, and capable of developing programmes using FORTRAN. The result of about 220 KB/s was obtained for the data transfer rate between the programmes of the host computer and terminals, and this fulfilled the aimed performance. The terminal system on the low energy side is provided with an ADC interface and a display interface specified particularly in addition to the miniature computer PFU400 and standard I/O devices of the manufacture. The accumulating type graphic display of the I/O devices can be switched to be connected to the host computer, and immediately displays the results transferred to the host computer and analyzed. Hard copy is also available. The above hardware and software are explained. The on-line system insures 80 K bytes of the total memory of 224 K bytes for data area. (Wakatsuki, Y.)

  18. Sport Management Taught On-Line: A Discussion

    Directory of Open Access Journals (Sweden)

    William F. Stier Jr

    2009-01-01

    Full Text Available An introduction to the world of on-line courses (distance education/learning is presented. In addition, the world of on-line learning, as it pertains to sport management, is examined within the framework of (a pedagogy, (b finances,(c assessment, and (d choosing to transition from the traditional classroom to on-line learning. Pertinent points relative to each of the four categories are presented from the literature. In an effort to stimulate thought and discussion to the subject of on-line learning for sport management programs/courses the authors provide their reactions to the literature points by presenting their comments/reactions from a sport management perspective. Sport management professors and administrators are encouraged to critically examine the feasibility of such on-line courses (distance education/learning within their own curricula while maintaining an appropriate framework revolving around sound theoretical instructional strategies, methods as well as appropriate use of instructional tools, including but not limited to, computersand the WWW.

  19. A reconfigurable on-line learning spiking neuromorphic processor comprising 256 neurons and 128K synapses.

    Science.gov (United States)

    Qiao, Ning; Mostafa, Hesham; Corradi, Federico; Osswald, Marc; Stefanini, Fabio; Sumislawska, Dora; Indiveri, Giacomo

    2015-01-01

    Implementing compact, low-power artificial neural processing systems with real-time on-line learning abilities is still an open challenge. In this paper we present a full-custom mixed-signal VLSI device with neuromorphic learning circuits that emulate the biophysics of real spiking neurons and dynamic synapses for exploring the properties of computational neuroscience models and for building brain-inspired computing systems. The proposed architecture allows the on-chip configuration of a wide range of network connectivities, including recurrent and deep networks, with short-term and long-term plasticity. The device comprises 128 K analog synapse and 256 neuron circuits with biologically plausible dynamics and bi-stable spike-based plasticity mechanisms that endow it with on-line learning abilities. In addition to the analog circuits, the device comprises also asynchronous digital logic circuits for setting different synapse and neuron properties as well as different network configurations. This prototype device, fabricated using a 180 nm 1P6M CMOS process, occupies an area of 51.4 mm(2), and consumes approximately 4 mW for typical experiments, for example involving attractor networks. Here we describe the details of the overall architecture and of the individual circuits and present experimental results that showcase its potential. By supporting a wide range of cortical-like computational modules comprising plasticity mechanisms, this device will enable the realization of intelligent autonomous systems with on-line learning capabilities.

  20. Object-Oriented Control System Design Using On-Line Training of Artificial Neural Networks

    Science.gov (United States)

    Rubaai, Ahmed

    1997-01-01

    This report deals with the object-oriented model development of a neuro-controller design for permanent magnet (PM) dc motor drives. The system under study is described as a collection of interacting objects. Each object module describes the object behaviors, called methods. The characteristics of the object are included in its variables. The knowledge of the object exists within its variables, and the performance is determined by its methods. This structure maps well to the real world objects that comprise the system being modeled. A dynamic learning architecture that possesses the capabilities of simultaneous on-line identification and control is incorporated to enforce constraints on connections and control the dynamics of the motor. The control action is implemented "on-line", in "real time" in such a way that the predicted trajectory follows a specified reference model. A design example of controlling a PM dc motor drive on-line shows the effectiveness of the design tool. This will therefore be very useful in aerospace applications. It is expected to provide an innovative and noval software model for the rocket engine numerical simulator executive.

  1. Surface quality monitoring for process control by on-line vibration analysis using an adaptive spline wavelet algorithm

    Science.gov (United States)

    Luo, G. Y.; Osypiw, D.; Irle, M.

    2003-05-01

    The dynamic behaviour of wood machining processes affects the surface finish quality of machined workpieces. In order to meet the requirements of increased production efficiency and improved product quality, surface quality information is needed for enhanced process control. However, current methods using high price devices or sophisticated designs, may not be suitable for industrial real-time application. This paper presents a novel approach of surface quality evaluation by on-line vibration analysis using an adaptive spline wavelet algorithm, which is based on the excellent time-frequency localization of B-spline wavelets. A series of experiments have been performed to extract the feature, which is the correlation between the relevant frequency band(s) of vibration with the change of the amplitude and the surface quality. The graphs of the experimental results demonstrate that the change of the amplitude in the selective frequency bands with variable resolution (linear and non-linear) reflects the quality of surface finish, and the root sum square of wavelet power spectrum is a good indication of surface quality. Thus, surface quality can be estimated and quantified at an average level in real time. The results can be used to regulate and optimize the machine's feed speed, maintaining a constant spindle motor speed during cutting. This will lead to higher level control and machining rates while keeping dimensional integrity and surface finish within specification.

  2. [Applications and prospects of on-line near infrared spectroscopy technology in manufacturing of Chinese materia medica].

    Science.gov (United States)

    Li, Yang; Wu, Zhi-Sheng; Pan, Xiao-Ning; Shi, Xin-Yuan; Guo, Ming-Ye; Xu, Bing; Qiao, Yan-Jiang

    2014-10-01

    The quality of Chinese materia medica (CMM) is affected by every process in CMM manufacturing. According to multi-unit complex features in the production of CMM, on-line near infrared spectroscopy (NIR) is used as an evaluating technology with its rapid, non-destructive and non-pollution etc. advantages. With the research in institutions, the on-line NIR applied in process analysis and control of CMM was described systematically, and the on-line NIR platform building was used as an example to clarify the feasibility of on-line NIR technology in CMM manufacturing process. Then, from the point of application by pharmaceutical companies, the current on-line NIR research on CMM and its production in pharmaceutical companies was relatively comprehensively summarized. Meanwhile, the types of CMM productions were classified in accordance with two formulations (liquid and solid dosage formulations). The different production processes (extraction, concentration and alcohol precipitation, etc. ) were used as liquid formulation diacritical points; the different types (tablets, capsules and plasters, etc.) were used as solid dosage formulation diacritical points, and the reliability of on-line NIR used in the whole process in CMM production was proved in according to the summary of literatures in recent 10 years, which could support the modernization of CMM production.

  3. On Line Service Composition in the Integrated Clinical Environment for eHealth and Medical Systems.

    Science.gov (United States)

    García-Valls, Marisol; Touahria, Imad Eddine

    2017-06-08

    Medical and eHealth systems are progressively realized in the context of standardized architectures that support safety and ease the integration of the heterogeneous (and often proprietary) medical devices and sensors. The Integrated Clinical Environment (ICE) architecture appeared recently with the goal of becoming a common framework for defining the structure of the medical applications as concerns the safe integration of medical devices and sensors. ICE is simply a high level architecture that defines the functional blocks that should be part of a medical system to support interoperability. As a result, the underlying communication backbone is broadly undefined as concerns the enabling software technology (including the middleware) and associated algorithms that meet the ICE requirements of the flexible integration of medical devices and services. Supporting the on line composition of services in a medical system is also not part of ICE; however, supporting this behavior would enable flexible orchestration of functions (e.g., addition and/or removal of services and medical equipment) on the fly. iLandis one of the few software technologies that supports on line service composition and reconfiguration, ensuring time-bounded transitions across different service orchestrations; it supports the design, deployment and on line reconfiguration of applications, which this paper applies to service-based eHealth domains. This paper designs the integration between ICE architecture and iLand middleware to enhance the capabilities of ICE with on line service composition and the time-bounded reconfiguration of medical systems based on distributed services. A prototype implementation of a service-based eHealth system for the remote monitoring of patients is described; it validates the enhanced capacity of ICE to support dynamic reconfiguration of the application services. Results show that the temporal cost of the on line reconfiguration of the eHealth application is bounded

  4. Initiating Events Modeling for On-Line Risk Monitoring Application

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.

    1998-01-01

    In order to make on-line risk monitoring application of Probabilistic Risk Assessment more complete and realistic, a special attention need to be dedicated to initiating events modeling. Two different issues are of special importance: one is how to model initiating events frequency according to current plant configuration (equipment alignment and out of service status) and operating condition (weather and various activities), and the second is how to preserve dependencies between initiating events model and rest of PRA model. First, the paper will discuss how initiating events can be treated in on-line risk monitoring application. Second, practical example of initiating events modeling in EPRI's Equipment Out of Service on-line monitoring tool will be presented. Gains from application and possible improvements will be discussed in conclusion. (author)

  5. Strengthening weak ties through on-line gaming

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana Virginia; Kirchner, Kathrin

    On-line gaming became widespread in the last couple of years. The aim of the research presented in the paper is to figure out to what extent does game playing helps to strengthen weak ties and what additional factors influence this process. The approach is rather exploratory – some factors...... are grounded in theory, some are new. These factors are age, gender, place of origin, number of their Facebook connections (friends in Facebook terminology), the amount of time they are on Facebook, the amount of time they keep the Facebook site open, the amount of time they play on-line games, and the reasons...... for starting to play on-line games. Regarding the latter, we chose to focus only on escapist reasons....

  6. Thermographic Sensing For On-Line Industrial Control

    Science.gov (United States)

    Holmsten, Dag

    1986-10-01

    It is today's emergence of thermoelectrically cooled, highly accurate infrared linescanners and imaging systems that has definitely made on-line Infraread Thermography (IRT) possible. Specifically designed for continuous use, these scanners are equipped with dedicated software capable of monitoring and controlling highly complex thermodynamic situations. This paper will outline some possible implications of using IRT on-line by describing some uses of this technology in the steel-making (hot rolling) and automotive industries (machine-vision). A warning is also expressed that IRT technology not originally designed for automated applications e.g. high resolution, imaging systems, should not be directly applied to an on-line measurement situation without having its measurement resolution, accuracy and especially its repeatability, reliably proven. Some suitable testing procedures are briefly outlined at the end of the paper.

  7. An on-line monitoring system for navigation equipment

    Science.gov (United States)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  8. On-line calculation of 3-D power distribution

    International Nuclear Information System (INIS)

    Park, Y. H.; In, W. K.; Park, J. R.; Lee, C. C.; Auh, G. S.

    1996-01-01

    The 3-D power distribution synthesis scheme was implemented in Totally Integrated Core Operation Monitoring System (TICOMS), which is under development as the next generation core monitoring system. The on-line 3-D core power distribution obtained from the measured fixed incore detector readings is used to construct the hot pin power as well as the core average axial power distribution. The core average axial power distribution and the hot pin power of TICOMS were compared with those of the current digital on-line core monitoring system, COLSS, which construct the core average axial power distribution and the pseudo hot pin power. The comparison shows that TICOMS results in the slightly more accurate core average axial power distribution and the less conservative hot pin power. Therefore, these results increased the core operating margins. In addition, the on-line 3-D power distribution is expected to be very useful for the core operation in the future

  9. UNISOR on-line nuclear orientation facility (UNISOR/NOF)

    International Nuclear Information System (INIS)

    Girit, I.C.; Alton, G.D.; Bingham, C.R.; Carter, H.K.; Simpson, M.L.; Cole, J.D.; Croft, W.L.; Hamilton, J.H.; Jones, E.F.; Gore, P.M.; Kormicki, J.; Xie, H.; Kern, B.D.; Krane, K.S.; Xu, Y.S.; Mantica, P.F. Jr.; Zimmermann, B.E.; Nettles, W.G.; Zganjar, E.F.; Kortelahti, M.O.; Newbolt, W.B.

    1988-01-01

    The UNISOR on-line nuclear orientation facility (UNISOR/NOF) consists of a 3 He- 4 He dilution refrigerator on line to the isotope separator. Nuclei are implanted directly into a target foil which is soldered to the bottom accessed cold finger of the refrigerator. A 1.5 T superconducting magnet polarizes the ferromagnetic target foils and determines the axis of symmetry. Up to eight gamma detectors can be positioned around the refrigerator, each 9 cm from the target. A unique feature of this system is that the k=4 term in the directional distribution function can be directly and unambigously deduced so that a single solution for the mixing ratio can be found. The first on-line experiment at this facility reported here was a study of the decay of the 191 Hg and 193 Hg isotopes. (orig.)

  10. Making the most of on-line recruiting.

    Science.gov (United States)

    Cappelli, P

    2001-03-01

    Ninety percent of large U.S. companies are already recruiting via the Internet. By simply logging on to the Web, company recruiters can locate vast numbers of qualified candidates for jobs at every level, screen them in minutes, and contact the most promising ones immediately. The payoffs can be enormous: it costs substantially less to hire someone on-line, and the time saved is equally great. In this article, Peter Cappelli examines some of the emerging service providers and technologies--matchmakers, job boards, hiring management systems software, and applicant-screening mechanisms that test skills and record interests. He also looks at some of the strategies companies are adopting as they enter on-line labor markets. Recruiting needs to be refashioned to resemble marketing, he stresses. Accordingly, smart companies are designing Web pages, and even product ads, with potential recruits in mind. They're giving line managers authority to hire so that candidates in cyberspace aren't lost. They're building internal on-line job networks to retain talent. Integrating recruiting efforts with overall marketing campaigns, especially through coordination and identification with the company's brand, is the most important thing companies can do to ensure success in on-line hiring. Along the way, Cappelli sounds two cautionary notes. First, a human touch, not electronic contact, is vital in the last steps of a successful hiring process. Second, companies must make sure that on-line testing and hiring criteria do not discriminate against women, disabled people, workers over 40, or members of minority groups. When competition for talent is fierce, companies that master the art and science of on-line recruiting will be the ones that attract and keep the best people.

  11. Radiation source states on-line supervision system design and implementation based on RFID technology

    International Nuclear Information System (INIS)

    Yang Binhua; Ling Qiu; Yin Guoli; Yang Kun; Wan Xueping; Wang Kan

    2011-01-01

    It puts forward radiation source states on-line monitoring resolution based on RFID technology. Firstly, the system uses RFID in real-time transmission of the radiation dose rate, and monitors the radiation source states and dose rate of the surrounding environment on-line. Then it adopts regional wireless networking mode to construct enterprise level monitoring network, which resolves long-distance wiring problems. And then it uses GPRS wireless to transport the real-time data to the monitoring center and the government supervision department, By adopting randomly dynamic cording in display update every day, it strengthens the supervision of the radiation source. At last this system has been successful applied to a thickness gauge project, which verifies the feasibility and practicality is good. (authors)

  12. On-Line Tracking Controller for Brushless DC Motor Drives Using Artificial Neural Networks

    Science.gov (United States)

    Rubaai, Ahmed

    1996-01-01

    A real-time control architecture is developed for time-varying nonlinear brushless dc motors operating in a high performance drives environment. The developed control architecture possesses the capabilities of simultaneous on-line identification and control. The dynamics of the motor are modeled on-line and controlled using an artificial neural network, as the system runs. The control architecture combines the experience and dependability of adaptive tracking systems with potential and promise of the neural computing technology. The sensitivity of real-time controller to parametric changes that occur during training is investigated. Such changes are usually manifested by rapid changes in the load of the brushless motor drives. This sudden change in the external load is simulated for the sigmoidal and sinusoidal reference tracks. The ability of the neuro-controller to maintain reasonable tracking accuracy in the presence of external noise is also verified for a number of desired reference trajectories.

  13. Modeling a multivariable reactor and on-line model predictive control.

    Science.gov (United States)

    Yu, D W; Yu, D L

    2005-10-01

    A nonlinear first principle model is developed for a laboratory-scaled multivariable chemical reactor rig in this paper and the on-line model predictive control (MPC) is implemented to the rig. The reactor has three variables-temperature, pH, and dissolved oxygen with nonlinear dynamics-and is therefore used as a pilot system for the biochemical industry. A nonlinear discrete-time model is derived for each of the three output variables and their model parameters are estimated from the real data using an adaptive optimization method. The developed model is used in a nonlinear MPC scheme. An accurate multistep-ahead prediction is obtained for MPC, where the extended Kalman filter is used to estimate system unknown states. The on-line control is implemented and a satisfactory tracking performance is achieved. The MPC is compared with three decentralized PID controllers and the advantage of the nonlinear MPC over the PID is clearly shown.

  14. The User-friendly On-Line Diffusion Chamber

    CERN Document Server

    Aviles Acosta, Jaime

    2015-01-01

    The On-Line Diffusion Chamber is a stand-alone apparatus built to carry out short-live radiotracer diffusion studies. The availability of the on-demand production of isotopes in the ISOLDE facility, and the design of the apparatus to streamline the implantation process, annealing treatment, ion gun ablation with a tape transport system, and radiation intensity measurement with a Ge gamma detector all in the same apparatus, gives the On-Line Diffusion Chamber a unique ability to studies with short-lived radioisotopes or isomer states that are not possible in any other facility in the world.

  15. The rationalization of desulfurization by on-line analysis

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Y; Kohmura, S; Taketomi, H; Matsumura, S; Sasaki, Y

    1986-01-01

    Nippon Kokan uses the Takahax and Sulfiban processes for the desulfurization of coke oven gas. The authors outline the Sulfiban Process and describe a recently developed system for the on-line determination of H/sub 2/S in coke oven gas, and of CO/sub 2/ and monoethanolamine (MEA) in the wash oil. This new on-line analysis system has proved effective in rationalizing the Sulfiban Process via lower MEA production costs and decreased power consumption. The introduction of a computerized control system is now being studied. 7 figs., 4 tabs.

  16. 5th Computer Science On-line Conference

    CERN Document Server

    Senkerik, Roman; Oplatkova, Zuzana; Silhavy, Petr; Prokopova, Zdenka

    2016-01-01

    This volume is based on the research papers presented in the 5th Computer Science On-line Conference. The volume Artificial Intelligence Perspectives in Intelligent Systems presents modern trends and methods to real-world problems, and in particular, exploratory research that describes novel approaches in the field of artificial intelligence. New algorithms in a variety of fields are also presented. The Computer Science On-line Conference (CSOC 2016) is intended to provide an international forum for discussions on the latest research results in all areas related to Computer Science. The addressed topics are the theoretical aspects and applications of Computer Science, Artificial Intelligences, Cybernetics, Automation Control Theory and Software Engineering.

  17. Comparison of Current On-line Payment Technologies

    OpenAIRE

    Mandadi, Ravi

    2006-01-01

    The purpose of this thesis work was to make a survey of current on-line payment technologies and find out which are they and how do they work? Compare and analyze them from a security point of view, as well as a usability point of view. What is good? What is bad? What is lacking? To achieve this purpose, an overview of the current on-line payment technologies was acquired through academic books and papers, Internet sites, magazines. Basic cryptographic and security related techniques were stu...

  18. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  19. On-Line Generation of 3D-Waves

    DEFF Research Database (Denmark)

    Frigaard, Peter

    1992-01-01

    The paper describes the technique of filtering white noise for on-line generation of 3D-waves on a small computer in the laboratory. The wave generation package is implemented and tested in the 3D-wave basin at the University of Aalborg.......The paper describes the technique of filtering white noise for on-line generation of 3D-waves on a small computer in the laboratory. The wave generation package is implemented and tested in the 3D-wave basin at the University of Aalborg....

  20. Adaptive control based on an on-line parameter estimation of an upper limb exoskeleton.

    Science.gov (United States)

    Riani, Akram; Madani, Tarek; Hadri, Abdelhafid El; Benallegue, Abdelaziz

    2017-07-01

    This paper presents an adaptive control strategy for an upper-limb exoskeleton based on an on-line dynamic parameter estimator. The objective is to improve the control performance of this system that plays a critical role in assisting patients for shoulder, elbow and wrist joint movements. In general, the dynamic parameters of the human limb are unknown and differ from a person to another, which degrade the performances of the exoskeleton-human control system. For this reason, the proposed control scheme contains a supplementary loop based on a new efficient on-line estimator of the dynamic parameters. Indeed, the latter is acting upon the parameter adaptation of the controller to ensure the performances of the system in the presence of parameter uncertainties and perturbations. The exoskeleton used in this work is presented and a physical model of the exoskeleton interacting with a 7 Degree of Freedom (DoF) upper limb model is generated using the SimMechanics library of MatLab/Simulink. To illustrate the effectiveness of the proposed approach, an example of passive rehabilitation movements is performed using multi-body dynamic simulation. The aims is to maneuver the exoskeleton that drive the upper limb to track desired trajectories in the case of the passive arm movements.

  1. Automatic data acquisition and on-line analysis of trace element concentration in serum samples

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.

    1978-01-01

    A completely automated system has been developed to determine the trace element concentration in biological samples by measuring charged particle induced X-rays. A CDC-3100 computer with ADC and CAMAC interface is employed to control the data collection apparatus, acquire data and perform simultaneously the analysis. The experimental set-up consists of a large square plexiglass chamber in which a commercially available 750H Kodak Carousel is suitably arranged as a computer controlled sample changer. A method of extracting trace element concentrations using reference spectra is presented and an on-line program has been developed to easily and conveniently obtain final results at the end of each run. (Auth.)

  2. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn...

  3. Integrated sensor array for on-line monitoring micro bioreactors

    NARCIS (Netherlands)

    Krommenhoek, E.E.

    2007-01-01

    The “Fed��?batch on a chip��?��?project, which was carried out in close cooperation with the Technical University of Delft, aims to miniaturize and parallelize micro bioreactors suitable for on-line screening of micro-organisms. This thesis describes an electrochemical sensor array which has been

  4. On-Line Pesticide Training with Narrated Powerpoint Presentations

    Science.gov (United States)

    Johnson, Steven B.

    2015-01-01

    UMaine Cooperative Extension is the primary educational delivery organization for pesticide recertification credits in Maine. Shrinking budgets and staff numbers are making traditional face-to-face delivery increasingly difficult to maintain. To address this issue, on-line pesticide applicator recertification training credits were developed. The…

  5. Personality Interactions and Scaffolding in On-Line Discussions

    Science.gov (United States)

    Nussbaum, E. Michael; Hartley, Kendall; Sinatra, Gale M.; Reynolds, Ralph E.; Bendixen, Lisa D.

    2004-01-01

    The potential of on-line discussions to prompt greater reflection of course material is often stymied by a tendency of students to agree with one another rather than to formulate counter-arguments. This article describes an experiment using note starters and elaborated cases to encourage counter-argumentation and examines interactions with…

  6. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.; Hubert, F.; Llabador, Y.; Mauhourat, M.B.; Bimbot, R.; Gardes, D.; Rivet, M.F.

    1981-01-01

    The working conditions of a new on-line electrostatic collection system are presented. The main characteristics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given. (orig.)

  7. Specialization processes in on-line unsupervised learning

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Reents, G.; Schlösser, E.

    1998-01-01

    From the recent analysis of supervised learning by on-line gradient descent in multilayered neural networks it is known that the necessary process of student specialization can be delayed significantly. We demonstrate that this phenomenon also occurs in various models of unsupervised learning. A

  8. On-Line Synthesis and Analysis by Mass Spectrometry

    Science.gov (United States)

    Bain, Ryan M.; Pulliam, Christopher J.; Raab, Shannon A.; Cooks, R. Graham

    2015-01-01

    In this laboratory experiment, students learn how to use ESI to accelerate chemical synthesis and to couple it with on-line mass spectrometry for structural analysis. The Hantzsch synthesis of symmetric 1,4-dihydropyridines is a classic example of a one-pot reaction in which multiple intermediates can serve to indicate the progress of the reaction…

  9. An optimal algorithm for preemptive on-line scheduling

    NARCIS (Netherlands)

    Chen, B.; Vliet, van A.; Woeginger, G.J.

    1995-01-01

    We investigate the problem of on-line scheduling jobs on m identical parallel machines where preemption is allowed. The goal is to minimize the makespan. We derive an approximation algorithm with worst-case guarantee mm/(mm - (m - 1)m) for every m 2, which increasingly tends to e/(e - 1) ˜ 1.58 as m

  10. Comparison between constant methanol feed and on-line ...

    African Journals Online (AJOL)

    Two methanol feeding methods, namely constant methanol feed and on-line monitoring feed control by methanol sensor were investigated to improve the production of recombinant human growth hormone (rhGH) in high cell density cultivation of Pichia pastoris KM71 in 2 L bioreactor. The yeast utilized glycerol as a carbon ...

  11. Children's On-Line Processing of Scrambling in Japanese

    Science.gov (United States)

    Suzuki, Takaaki

    2013-01-01

    This study investigates the on-line processing of scrambled sentences in Japanese by preschool children and adults using a combination of self-paced listening and speeded picture selection tasks. The effects of a filler-gap dependency, reversibility, and case markers were examined. The results show that both children and adults had difficulty in…

  12. AAEC INIS - a large, new, on-line information source

    International Nuclear Information System (INIS)

    Rugg, T.J.; Wong, S.C.

    1984-01-01

    The Australian Atomic Energy Commission's INIS database is available for on-line searching by non-AAEC personnel from all parts of Australia. An introduction to the International Nuclear Information System is followed by information on searching AAEC INIS, AAEC INIS retrieval software and accessing AAEC INIS

  13. ORION-the Omega Remote Interactive On-line System

    CERN Document Server

    Russell, R D; Levratt, B; Lipps, H; Sparrman, P

    1974-01-01

    ORION is a system which permits the manipulation of files, records and characters, remote job submittal and retrieval of output files including the direct loading of remote on-line computers. The system uses the computer hardware of the OMEGA project at CERN and is designed to assist researchers in development and debugging of their programs. (10 refs).

  14. ORION - the OMEGA Remote Interactive On-line System

    CERN Document Server

    Russell, R D; Krieger, M

    1973-01-01

    ORION is a system which permits the manipulation of files, records and characters, remote job submittal and retrieval of output files including the direct loading of remote on-line computers. The system uses the computer hardware of the OMEGA project at CERN, and is designed to assist researchers in development and debugging of their programs.

  15. Booth Library On-Line Circulation System (BLOC

    Directory of Open Access Journals (Sweden)

    Paladugu V. Rao

    1971-06-01

    Full Text Available An on-line circulation system developed at a relatively small university library demonstrates that academic libraries with limited funds can develop automated systems utilizing parent institution's computer facilities in a time-sharing mode. In operation since September 1968, using an IBM 360/50 computer and associated peripheral equipment, it provides control over all stack books.

  16. On-line learning from clustered input examples

    NARCIS (Netherlands)

    Riegler, Peter; Biehl, Michael; Solla, Sara A.; Marangi, Carmela; Marinaro, Maria; Tagliaferri, Roberto

    1996-01-01

    We analyse on-line learning of a linearly separable rule with a simple perceptron. Example inputs are taken from two overlapping clusters of data and the rule is defined through a teacher vector which is in general not aligned with the connection line of the cluster centers. We find that the Hebb

  17. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2008-01-01

    Full Text Available The on-line user of today has access to a vast collection of information resources. In addition, the developments in Internet and Web technologies have made it even easier for surfers to anonymously get access to on-line pornography. The purpose of this research was to investigate the extent to which access to on-line pornography at the University of Johannesburg can be managed. For the empirical part of this research 1037 questionnaires were proportionally distributed to and completed by students on all five campuses of the university. The questionnaire consisted of four sections: biographical information; university computer facility usage; university acceptable use policy; and personal experience with university computer facilities. The gender distribution for the sample was almost even, with a total of 49,4% male participants and 50,6% female, with the largest grouping of respondents (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  18. On-line sample treatment - Capillary gas chromatography

    NARCIS (Netherlands)

    Goosens, EC; de Jong, D; de Jong, GJ; Brinkman, UAT

    Sample pretreatment is often the bottleneck of a trace level analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of

  19. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.

    1981-06-01

    The working conditions of a new on-line electrostatic collection system are presented. The main charactersitics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given

  20. Summary remarks and prospects for on-line nuclear orientation

    International Nuclear Information System (INIS)

    Krane, K.S.; Hamilton, J.H.

    1984-01-01

    This paper reviews the use of on-line nuclear orientations as a method for determining hyperfine structure. Historical developments and future prospects for the technique are presented. The role that this technique can play in nuclear spectroscopy and the study of nuclei far from the beta stability are outlined

  1. WMI2, the Student's On-Line Symbolic Calculator

    Science.gov (United States)

    Kovacs, Zoltan

    2011-01-01

    Student activities focused on discovering mathematics play an important role in the teaching and learning process. WebMathematics Interactive (WMI2) was developed to offer a fast and user-friendly on-line web interface to enhance the quality of both theoretical and applied mathematics courses. For the teacher, in the classroom, it provides…

  2. ADAPTIVE CONTEXT PROCESSING IN ON-LINE HANDWRITTEN CHARACTER RECOGNITION

    NARCIS (Netherlands)

    Iwayama, N.; Ishigaki, K.

    2004-01-01

    We propose a new approach to context processing in on-line handwritten character recognition (OLCR). Based on the observation that writers often repeat the strings that they input, we take the approach of adaptive context processing. (ACP). In ACP, the strings input by a writer are automatically

  3. Microcomputers as on-line catalogs in special libraries.

    Science.gov (United States)

    Faust, J B

    1986-01-01

    This article discusses the rationale for the conversion of a card catalog to an on-line system in a special library owning approximately 4000 titles. Equipment, software, and procedures are described. Pros and cons of the use of a microcomputer for such a project, as well as costs and personnel needs, are outlined.

  4. Efficient and secure comparison for on-line auctions

    NARCIS (Netherlands)

    Damgard, Ivan; Geisler, M.; Kroigaard, M.; Pieprzyk, J.; Ghodosi, H.; Dawson, E.

    2007-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption. We also propose a homomorphic encryption scheme that can be used in our protocol and makes it more efficient than previous solutions. Our protocol is well-suited for application in on-line auctions, both with

  5. The on-line asymmetric traveling salesman problem

    NARCIS (Netherlands)

    Ausiello, G.; Bonifaci, V.; Laura, L.

    2008-01-01

    We consider two on-line versions of the asymmetric traveling salesman problem with triangle inequality. For the homing version, in which the salesman is required to return in the city where it started from, we give a -competitive algorithm and prove that this is best possible. For the nomadic

  6. Facing regulatory challenges of on-line hemodiafiltration.

    Science.gov (United States)

    Kümmerle, Wolfgang

    2011-01-01

    On-line hemodiafiltration (on-line HDF) is the result of a vision that triggered multifarious changes in very different areas. Driven by the idea to offer better medical treatment for renal patients, technological innovations were developed and established that also constituted new challenges in the field of regulatory affairs. The existing regulations predominantly addressed the quality and safety of those products needed to perform dialysis treatment which were supplied by industrial manufacturers. However, the complexity of treatment system required for the provision of on-line fluids demanded a holistic approach encompassing all components involved. Hence, focus was placed not only on single products, but much more on their interfacing, and the clinical infrastructure, in particular, had to undergo substantial changes. The overall understanding of the interaction between such factors, quite different in their nature, was crucial to overcome the arising regulatory obstacles. This essay describes the evolution of the on-line HDF procedure from the regulatory point of view. A simplified diagram demonstrates the path taken from the former regulatory understanding to the realization of necessary changes. That achievement was only possible through 'management of preview' and consequent promotion of technical and medical innovations as well as regulatory re-evaluations. Copyright © 2011 S. Karger AG, Basel.

  7. Project development and commercialization of on-line analysis systems

    International Nuclear Information System (INIS)

    Watt, J.S.

    1997-01-01

    A project team first in the Australian Atomic Energy Commission (AAEC) and since 1982 in CSIRO has developed many on-line analysis systems for the mineral and energy industries. The development of these projects has followed a common pattern of laboratory R and D, field trials, commercialisation and technology transfer. This successful pattern is illustrated using examples of the development of systems for the on-line analysis of mineral slurries, for determination of the ash content of coal on conveyors, and for determination of the flow rates of oil, water and gas in pipelines. The first two systems are licensed to Australian companies, Amdel Ltd and Mineral Control Instrumentation Ltd. Both systems are used by industry worldwide, and are the market leaders for radioisotope gauges in their application field. The third system, the multiphase flow meter, was licensed in 1997 to Kvaerner FSSL Ltd of Aberdeen. This meter has even greater potential than the other two systems for economic benefit from its used and for numbers of installations. The on-line analysis systems have been developed to increase the productivity of the Australian mineral and energy industries, and to provide economic benefit to Australia. The economic benefit sought is predominantly improved process control based on use of the instrument, rather than from its sale. Sales of instruments are significant, however, with about A$80 million from the analysis systems and their derivatives since the 1970s. Some of the issues associated with the development of the on-line analysis system are outlined

  8. IOOS Data Portals and Uniform On-line Browse Capabilities

    Science.gov (United States)

    Howard, M.; Currier, R. D.; Kobara, S.; Gayanilo, F.

    2015-12-01

    The Gulf of Mexico Coastal Ocean Observing System Regional Association (GCOOS-RA) is one of eleven Regional Associations organized under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) Program Office. Each of the RAs operate standards-based regional data portals designed to aggregate near real-time and historical observed data and modeled outputs from distributed providers and to offer these and derived products in standardized ways to a diverse set of users. The RA's portals are based on the IOOS Data and Communications Plan which describes the functional elements needed for an interoperable system. One of these elements is called "Uniform On-line Browse" which is an informational service designed primarily to visualize the inventory of a portal. An on-line browse service supports the end user's need to discover what parameters are available, to learn the spatial and temporal extend of the holdings, and to examine the character of the data (e.g, variability, gappiness, etc). These pieces of information help the end user decide if the data are fit for his/her purpose and to construct valid data requests. Note that on-line browse is a distinctly different activity than data analysis because it seeks to yield knowledge about the inventory and not about what the data mean. "Uniform" on-line browse is a service that takes advantage of the standardization of the data portal's data access points. Most portals represent station locations on a map. This is a view of the data inventory but these plots are rarely generated by pulling data through the standards-based services offered to the end users but through methods only available to the portal programmers. This work will present results of Uniform On-line browse tools developed within GCOOS-RA and their applicability to other RA portals.

  9. Mentoring Narratives ON-LINE:Teaching the Principalship

    Directory of Open Access Journals (Sweden)

    Allison I. Griffith

    2002-05-01

    Full Text Available The need to develop new models for preparation of school administrators has been a prominent concern in educational discourse in the last decade. Having been criticized for the inadequate preparation of the school leadership cadre, academic departments responsible for training future school administrators have had to revisit their approaches and to reframe their teaching philosophies to ensure the readiness of their graduates for the challenges and complexities of school leadership. This article reports on the new model of principals' training that has been used in York University's Principals' Qualification Program (PQP from the late 1990s onward. One component of the program brings traditional case methodology into a computer-mediated/on-line environment. The on-line cases are narratives from the everyday lives of the Ontario school administrators who serve as mentors in the on-line environment. Situating our discussion within the context of the rapidly changing educational landscape of Ontario, we focus on the PQP model to explore experientially generated case narratives as one method for teaching and learning the work of the local school administrator. We focus particularly on the teaching and learning embedded in computer-mediated or on-line case narratives used in training teachers for school leadership. We argue that the complexities of school leadership—the social, cultural, relational, ethical and moral context of school leadership—can be taught effectively through the reflective processes of on-line case narratives. We seek to contribute to the ongoing dialogue on the potential of new pedagogies and new technologies to help prepare the competent and responsible leaders for tomorrow's schools.

  10. Automatic flow-through dynamic extraction: A fast tool to evaluate char-based remediation of multi-element contaminated mine soils.

    Science.gov (United States)

    Rosende, María; Beesley, Luke; Moreno-Jimenez, Eduardo; Miró, Manuel

    2016-02-01

    An automatic in-vitro bioaccessibility test based upon dynamic microcolumn extraction in a programmable flow setup is herein proposed as a screening tool to evaluate bio-char based remediation of mine soils contaminated with trace elements as a compelling alternative to conventional phyto-availability tests. The feasibility of the proposed system was evaluated by extracting the readily bioaccessible pools of As, Pb and Zn in two contaminated mine soils before and after the addition of two biochars (9% (w:w)) of diverse source origin (pine and olive). Bioaccessible fractions under worst-case scenarios were measured using 0.001 mol L(-1) CaCl2 as extractant for mimicking plant uptake, and analysis of the extracts by inductively coupled optical emission spectrometry. The t-test of comparison of means revealed an efficient metal (mostly Pb and Zn) immobilization by the action of olive pruning-based biochar against the bare (control) soil at the 0.05 significance level. In-vitro flow-through bioaccessibility tests are compared for the first time with in-vivo phyto-toxicity assays in a microcosm soil study. By assessing seed germination and shoot elongation of Lolium perenne in contaminated soils with and without biochar amendments the dynamic flow-based bioaccessibility data proved to be in good agreement with the phyto-availability tests. Experimental results indicate that the dynamic extraction method is a viable and economical in-vitro tool in risk assessment explorations to evaluate the feasibility of a given biochar amendment for revegetation and remediation of metal contaminated soils in a mere 10 min against 4 days in case of phyto-toxicity assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Direct thermal desorption in the analysis of cheese volatiles by gas chromatography and gas chromatography-mass spectrometry: comparison with simultaneous distillation-extraction and dynamic headspace.

    Science.gov (United States)

    Valero, E; Sanz, J; Martínez-Castro, I

    2001-06-01

    Direct thermal desorption (DTD) has been used as a technique for extracting volatile components of cheese as a preliminary step to their gas chromatographic (GC) analysis. In this study, it is applied to different cheese varieties: Camembert, blue, Chaumes, and La Serena. Volatiles are also extracted using other techniques such as simultaneous distillation-extraction and dynamic headspace. Separation and identification of the cheese components are carried out by GC-mass spectrometry. Approximately 100 compounds are detected in the examined cheeses. The described results show that DTD is fast, simple, and easy to automate; requires only a small amount of sample (approximately 50 mg); and affords quantitative information about the main groups of compounds present in cheeses.

  12. Advances in the helium-jet coupled on-line mass seperator RAMA

    International Nuclear Information System (INIS)

    Moltz, D.M.; Aeystoe, J.; Cable, M.D.; Parry, R.F.; Haustein, P.E.; Wouters, J.M.; Cerny, J.; California Univ., Berkeley

    1981-01-01

    General improvements to the on-line mass separator RAMA have yielded a greater reliability and efficiency for some elements. A new utilitarian helium-jet chamber has been installed to facilitate quick target and degrader foil changes in addition to a new ion source holder. A higher efficiency hollow-cathode, cathode-extraction ion source for lower melting point elements ( 0 C) has also been designed. Tests with the beta-delayed proton emitter 37 Ca showed a factor of five increase in yield over the old hollow-cathode, anode-extraction source. A differentially-pumped tape drive system compatible with both γ-γ and β-γ experiments has been incorporated into the general detection system. All major operating parameters will soon be monitored by a complete stand-alone microprocessor system which will eventually be upgraded to a closed-loop control system. (orig.)

  13. Advances in the helium-jet coupled on-line mass separator RAMA

    International Nuclear Information System (INIS)

    Moltz, D.M.; Aysto, J.; Cable, M.D.; Parry, R.F.; Haustein, P.E.; Wouters, J.M.; Cerny, J.

    1980-01-01

    General improvements to the on-line mass separator RAMA (Recoil Atom Mass Analyzer) have yielded a greater reliability and efficiency for some elements. A new utilitarian helium-jet chamber has been installed to facilitate quick target and degrader foil changes in addition to a new ion source holder. A higher efficiency hollow-cathode, cathode-extraction ion source, for lower melting point elements ( 0 C) has also been designed. Tests with the beta-delayed proton emitter 37 Ca showed a factor of five increase in yield over the old hollow-cathode, anode-extraction source. A differentially-pumped-tape drive system compatible with both γ-γ and β-γ experiments has been incorporated into the general detection system. All major operating parameters will soon be monitored by a complete stand-alone microprocessor system which will eventually be upgraded to a closed-loop control system

  14. On-line analysis of water contamination by organic compounds; On-line-Analytik der Wasserverschmutzung durch organische Substanzen

    Energy Technology Data Exchange (ETDEWEB)

    Wagt, R. van der; Vos, F. de [Skalar Analytical (Netherlands); Babichenko, S.; Poryvkina, L. [Institute of Ecology, Tallinn (Estonia)

    1999-08-01

    In many environmental applications decomposing the mixture of substances in the water into its various chemical ingredients, for subsequent analysis, is a very complicated task. The most productive approach to on-line diagnosis is to treat the object as an integral spectroscopic sample, characterized by certain specific Spectral Fluorescent Signatures (SFS). The SFS are recorded as a matrix of fluorescent intensity of organic compounds in water, in co-ordinates of excitation and emission spectra, providing a three-dimensional spectrum. Spectral windows of SFS are defined by fluorescent characteristics of basic groups of organic substances in the water sample. The novel Skalar Fluo Imager, based on this principle, is intended for the analysis of organic compounds in natural, domestic, and technological waters in an on-line mode. (orig.) [German] In vielen Umweltschutzanwendungen stellt die Auftrennung eines Substanzgemisches zum Zweck der Analyse eine sehr komplizierte Aufgabe dar. Ein erfolgversprechender Ansatz fuer eine on-line-Diagnostik besteht darin, das Objekt als integrale Spektroskopieprobe zu betrachten, die durch bestimmte spezifische Spektral-Fluoreszenz-Signaturen (SFS) charakterisiert wird. Diese werden als Fluoreszenz-Intensitaets-Matrix organischer Verbindungen in Wasser dargestellt, mit Anregungs- und Emissionsspektren als weiteren Koordinaten, wodurch ein dreidimensionales Spektrum entsteht. Spektrale Fenster der SFS sind definiert als Fluoreszenzcharakteristika von Funktionsgruppen organischer Substanzen in der Wasserprobe. Der auf diesem Prinzip basierende Skalar Fluo Imager ist fuer die on-line-Analyse organischer Bestandteile in natuerlichen, Haus- und technischen Waessern gedacht. (orig.)

  15. Automatic Delineation of On-Line Head-And-Neck Computed Tomography Images: Toward On-Line Adaptive Radiotherapy

    International Nuclear Information System (INIS)

    Zhang Tiezhi; Chi Yuwei; Meldolesi, Elisa; Yan Di

    2007-01-01

    Purpose: To develop and validate a fully automatic region-of-interest (ROI) delineation method for on-line adaptive radiotherapy. Methods and Materials: On-line adaptive radiotherapy requires a robust and automatic image segmentation method to delineate ROIs in on-line volumetric images. We have implemented an atlas-based image segmentation method to automatically delineate ROIs of head-and-neck helical computed tomography images. A total of 32 daily computed tomography images from 7 head-and-neck patients were delineated using this automatic image segmentation method. Manually drawn contours on the daily images were used as references in the evaluation of automatically delineated ROIs. Two methods were used in quantitative validation: (1) the dice similarity coefficient index, which indicates the overlapping ratio between the manually and automatically delineated ROIs; and (2) the distance transformation, which yields the distances between the manually and automatically delineated ROI surfaces. Results: Automatic segmentation showed agreement with manual contouring. For most ROIs, the dice similarity coefficient indexes were approximately 0.8. Similarly, the distance transformation evaluation results showed that the distances between the manually and automatically delineated ROI surfaces were mostly within 3 mm. The distances between two surfaces had a mean of 1 mm and standard deviation of <2 mm in most ROIs. Conclusion: With atlas-based image segmentation, it is feasible to automatically delineate ROIs on the head-and-neck helical computed tomography images in on-line adaptive treatments

  16. R and D of On-line Reprocessing Technology for Molten-Salt Reactor Systems

    International Nuclear Information System (INIS)

    Uhlir, Jan; Tulackova, Radka; Chuchvalcova Bimova, Karolina

    2006-01-01

    The Molten Salt Reactor (MSR) represents one of promising future nuclear reactor concept included in the Generation IV reactors family. The reactor can be operated as the thorium breeder or as the actinide transmuter. However, the future deployment of Molten-Salt Reactors will be significantly dependent on the successful mastering of advanced reprocessing technologies dedicated to their fuel cycle. Here the on-line reprocessing technology connected with the fuel circuit of MSR is of special importance because the reactor cannot be operated for a long run without the fuel salt clean-up. Generally, main MSR reprocessing technologies are pyrochemical, majority of them are fluoride technologies. The proposed flow-sheets of MSR on-line reprocessing are based on a combination of molten-salt / liquid metal extraction and electro-separation processes, which can be added to the gas extraction process already verified during the MSRE project in ORNL. The crucial separation method proposed for partitioning of actinides from fission products is based on successive Anodic dissolution and Cathodic deposition processes in molten fluoride media. (authors)

  17. On-line structural damage localization and quantification using wireless sensors

    International Nuclear Information System (INIS)

    Hsu, Ting-Yu; Huang, Shieh-Kung; Lu, Kung-Chung; Loh, Chin-Hsiung; Wang, Yang; Lynch, Jerome Peter

    2011-01-01

    In this paper, a wireless sensing system is designed to realize on-line damage localization and quantification of a structure using a frequency response function change method (FRFCM). Data interrogation algorithms are embedded in the computational core of the wireless sensing units to extract the necessary structural features, i.e. the frequency spectrum segments around eigenfrequencies, automatically from measured structural response for the FRFCM. Instead of the raw time history of the structural response, the extracted compact structural features are transmitted to the host computer. As a result, with less data transmitted from the wireless sensors, the energy consumed by the wireless transmission is reduced. To validate the performance of the proposed wireless sensing system, a six-story steel building with replaceable bracings in each story is instrumented with the wireless sensors for on-line damage detection during shaking table tests. The accuracy of the damage detection results using the wireless sensing system is verified through comparison with the results calculated from data recorded of a traditional wired monitoring system. The results demonstrate that, by taking advantage of collocated computing resources in wireless sensors, the proposed wireless sensing system can locate and quantify damage with acceptable accuracy and moderate energy efficiency

  18. On-line radiometry in high-performance liquid chromatography using a storage loop

    International Nuclear Information System (INIS)

    Nieuwkerk, H.J. van.

    1987-01-01

    Difficulty with radiometric chromatography is that large measured volumes are required for accurate detections, but large volumes cause band widening and thus poor separation capacity. The solution proposed here is based on the use of a capillary storage loop for temporary residence of the column eluate. To avoid back mixing, the liquid is interspaced with a second, immiscible, phase ('spacer') so as to form a sequence of small 10-50 μl separate segments. This train passes the on-line radiometric detector to obtain a first scan of the chromatogram, called the 'direct' measurement. It then reaches the storage loop. The usual on-line UV measurement is done in the same run. The eluate cum spacer is, at a later stage, pumped through the detector at a greatly reduced flow rate to obtain the 'reversed' or 'delayed' measurement. Beta-detection is based on liquid scintillation. Accordingly, the (organic) liquid scintillant is used as the 'spacer'. In most cases it is possible to extract the analyte from the aqueous eluate into the organic phase during transport to and storage in the loop. This ensures a high counting efficiency. If the analyte is non-extractable, the counting efficiency is considerably less but the number of counts collected is still sufficient for quantitative assay, due to the extended counting time. The report is divided into 5 chapters, each dealing with a radiometric HPCL separation making use of this method. 36 figs.; 124 refs.; 16 tables

  19. On line performance monitoring for predictive maintenance [Paper No.: VIA - 2

    International Nuclear Information System (INIS)

    Gupta, R.K.; Chandra, Rajesh

    1981-01-01

    There will always be progressive deterioration in the performance of dynamic equipment due to normal inevitable wear, malfunctions, failures and other reasons. In most cases it is possible to monitor some parameters of a system which would get progressively affected with the deterioration in the health of the system. By on-line monitoring of such predetermined parameters, compared with preset base data generated for a healthy system earlier, would prove very helpful in avoiding breakdowns and in proper planning of preventive and predictive maintenance. With increasing use of on-line computerised controls the generation of design base data and also the in-built self checking feature of monitoring the equipment health can be achieved by incorporating suitable software. This type of system will be helpful in: (a) predicting the life of component, (b) prewarning the operator about impending malfunctions, (c) establishing a maintenance schedule and spare inventory, and (d) analysing the failures. This type of centralised predictive maintenance is increasingly becoming important where: (a) the number of equipments are large, (b) the operation of equipment is critical from safety criteria, and (c) the minimum safety margin in the performance of the component is to be maintained. Keeping this in mind, the Fuel Handling System of Narora Atomic Power Project and the future power plants having computerised controls will have facility for on-line performance monitoring for predictive maintenance. The paper also describes methodology of the technique in detail, with a few representative cases. (author)

  20. On-line analysis of bulk materials using pulsed neutron interrogation

    International Nuclear Information System (INIS)

    Lebrun, P.; Tourneur, P. Le; Poumarede, B.; Bach, P.; Moeller, H.

    1999-01-01

    On the basis of our joint experience in neutronics for SODERN and in cement plant engineering for KRUPP POLYSIUS, we have developed a new on-line bulk materials analyser for the cement industry. This equipment includes a pulsed neutron generator GENIE 16, some gamma ray and neutron detectors, specially designed electronics with high counting rate, software delivering the mean elemental composition of raw material, and adequate shielding. This material is transported through the equipment on a conveyor belt, the size of which is adapted to the requirements. This paper briefly describes the equipment and some results, as obtained in dynamic test from a demonstrator installed in Germany

  1. On-line analysis of bulk materials using pulsed neutron interrogation

    Science.gov (United States)

    Lebrun, P.; Tourneur, P. Le; Poumarede, B.; Möller, H.; Bach, P.

    1999-06-01

    On the basis of our joint experience in neutronics for SODERN and in cement plant engineering for KRUPP POLYSIUS, we have developed a new on-line bulk materials analyser for the cement industry. This equipment includes a pulsed neutron generator GENIE 16, some gamma ray and neutron detectors, specially designed electronics with high counting rate, software delivering the mean elemental composition of raw material, and adequate shielding. This material is transported through the equipment on a conveyor belt, the size of which is adapted to the requirements. This paper briefly describes the equipment and some results, as obtained in dynamic test from a demonstrator installed in Germany.

  2. On-line soft sensing in upstream bioprocessing.

    Science.gov (United States)

    Randek, Judit; Mandenius, Carl-Fredrik

    2018-02-01

    This review provides an overview and a critical discussion of novel possibilities of applying soft sensors for on-line monitoring and control of industrial bioprocesses. Focus is on bio-product formation in the upstream process but also the integration with other parts of the process is addressed. The term soft sensor is used for the combination of analytical hardware data (from sensors, analytical devices, instruments and actuators) with mathematical models that create new real-time information about the process. In particular, the review assesses these possibilities from an industrial perspective, including sensor performance, information value and production economy. The capabilities of existing analytical on-line techniques are scrutinized in view of their usefulness in soft sensor setups and in relation to typical needs in bioprocessing in general. The review concludes with specific recommendations for further development of soft sensors for the monitoring and control of upstream bioprocessing.

  3. On-line corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2004-01-01

    ), Electrochemical Noise (EN) and Zero Resistance Ammetry (ZRA). Electrochemical Resistance (ER) has also been used to measure corrosion. The method traditionally only measures corrosion off-line but with newly developed high-sensitive ER technique developed by MetriCorr in Denmark, on-line monitoring is possible...... complicates the chemistry of the environment. Hydrogen sulphide is present in geothermal systems and can be formed as a by-product of sulphate-reducing-bacteria (SRB). The application of electrochemical methods makes on-line monitoring possible. These methods include: Linear Polarization Resistance (LPR....... In order to assess both general corrosion and localized corrosion, it is necessary to apply more than one monitoring technique simultaneously, ZRA or EN for measuring localized corrosion and LPR or ER for measuring general corrosion rate. The advantage of monitoring localized corrosion is indisputable...

  4. On-line sources of toxicological information in Canada

    International Nuclear Information System (INIS)

    Racz, William J.; Ecobichon, Donald J.; Baril, Marc

    2003-01-01

    This paper will provide an overview of the on-line resources available in toxicology in Canada. It will describe a brief history of The Society of Toxicology of Canada, with reference to other societies and also provide information on education, research and other resources related to toxicology. Toxicology in Canada emerged as a distinct and vibrant discipline following the thalidomide tragedy of the 1960s. In the pharmaceutical industry and government, toxicology was readily established as an essential component of drug development and safety, and as the need for toxicologists expanded, training programs were established, usually in collaboration with departments of pharmacology. In the last two to three decades other disciplines, environmental biology, analytical chemistry and epidemiology joined the ranks of toxicology. The on-line sources of toxicology information are rapidly expanding. This article describes those sources considered by the authors to be important from a national and international perspective. The majority of these sources are professional organizations and government agencies

  5. On-line chemistry monitoring for the secondary side

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Babcock and Wilcox (B and W) has developed a computerized water chemistry data acquisition and management system for nuclear plant secondary coolant systems. The Integrated Water Chemistry Monitoring System (IWCMS) provides on-line monitoring of conditions and rapid trend analysis of sampled data. So far it has been installed at GPU Three Mile Island unit 1 and at Toledo Edison Davis-Besse. The IWCMS meets the following utility needs for monitoring power plant chemistry: control of chemistry conditions to minimize corrosion and extend component/system life; continuous analysis of data from on-line detectors and grab samples; expediting of transient recovery actions with trend, alarm and evaluation capability; provision for rapid sharing of useful operational chemistry information; concentration of attention on evaluation instead of data manipulation. The system is composed of three functional parts: data acquisition hardware; PC-based computer system and customised system software. (author)

  6. On-line application of the PANTHER advanced nodal code

    International Nuclear Information System (INIS)

    Hutt, P.K.; Knight, M.P.

    1992-01-01

    Over the last few years, Nuclear Electric has developed an integrated core performance code package for both light water reactors (LWRs) and advanced gas-cooled reactors (AGRs) that can perform a comprehensive range of calculations for fuel cycle design, safety analysis, and on-line operational support for such plants. The package consists of the following codes: WIMS for lattice physics, PANTHER whole reactor nodal flux and AGR thermal hydraulics, VIPRE for LWR thermal hydraulics, and ENIGMA for fuel performance. These codes are integrated within a UNIX-based interactive system called the Reactor Physics Workbench (RPW), which provides an interactive graphic user interface and quality assurance records/data management. The RPW can also control calculational sequences and data flows. The package has been designed to run both off-line and on-line accessing plant data through the RPW

  7. UniFlex - Collaborative on-line learning environment tool

    Directory of Open Access Journals (Sweden)

    Ole Borch

    2004-05-01

    Full Text Available

    Første gang publiceret i UNEV nr. 2: E-læringsplatforme - muligheder og potentialer, januar - marts 2004, red. Tom Nyvand og Michael Pedersen. ISSN 1603-5518.

    Increasing demands for remote on-line education are changing the way teaching and learning is performed. New behavior in using pedagogy and supporting technology is needed to drive the learning process. To facilitate the use of services for selected activities to participants in distance education, a web site named UniFlex (University Flexible learning has been developed and brought into use. The site is a comprehensive set of bookmarks including course taking, upload/download, and - of special significance - collaborative on-line project work. UniFlex has been developed to meet the requirement for a simple and cheap personalized interactive site, supporting problem oriented and project organized study form, which has characterized Aalborg University for more than 27 years.

  8. UniFlex - Collaborative on-line learning environment tool

    Directory of Open Access Journals (Sweden)

    Ole Borch

    2004-03-01

    Full Text Available Første gang publiceret i UNEV nr. 2: E-læringsplatforme - muligheder og potentialer, januar - marts 2004, red. Tom Nyvand og Michael Pedersen. ISSN 1603-5518. Increasing demands for remote on-line education are changing the way teaching and learning is performed. New behavior in using pedagogy and supporting technology is needed to drive the learning process. To facilitate the use of services for selected activities to participants in distance education, a web site named UniFlex (University Flexible learning has been developed and brought into use. The site is a comprehensive set of bookmarks including course taking, upload/download, and - of special significance - collaborative on-line project work. UniFlex has been developed to meet the requirement for a simple and cheap personalized interactive site, supporting problem oriented and project organized study form, which has characterized Aalborg University for more than 27 years.

  9. On-line analyzers to distributed control system linking

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, S.F.; Buchanan, B.R.; Sanders, M.A.

    1990-01-01

    The Analytical Development Section (ADS) of the Savannah River Laboratory is developing on-line analyzers to monitor various site processes. Data from some of the on-line analyzers (OLA's) will be used for process control by distributed control systems (DCS's) such as the Fisher PRoVOX. A problem in the past has been an efficient and cost effective way to get analyzer data onto the DCS data highway. ADS is developing a system to accomplish the linking of OLA's to PRoVOX DCS's. The system will be described, and results of operation in a research and development environment given. Plans for the installation in the production environment will be discussed.

  10. On-line Ramsey Numbers for Paths and Stars

    Directory of Open Access Journals (Sweden)

    Jaroslaw Grytczuk

    2008-08-01

    Full Text Available We study on-line version of size-Ramsey numbers of graphs defined via a game played between Builder and Painter: in one round Builder joins two vertices by an edge and Painter paints it red or blue. The goal of Builder is to force Painter to create a monochromatic copy of a fixed graph H in as few rounds as possible. The minimum number of rounds (assuming both players play perfectly is the on-line Ramsey number r(H of the graph H. We determine exact values of r(H for a few short paths and obtain a general upper bound r(Pn ≤ 4n-7. We also study asymmetric version of this parameter when one of the target graphs is a star Sn with n edges. We prove that r(Sn,H≤n ·e(H when H is any tree, cycle or clique.

  11. Laser systems for on-line laser ion sources

    International Nuclear Information System (INIS)

    Geppert, Christopher

    2008-01-01

    Since its initiation in the middle of the 1980s, the resonant ionization laser ion source has been established as a reliable and efficient on-line ion source for radioactive ion beams. In comparison to other on-line ion sources it comprises the advantages of high versatility for the elements to be ionized and of high selectivity and purity for the ion beam generated by resonant laser radiation. Dye laser systems have been the predominant and pioneering working horses for laser ion source applications up to recently, but the development of all-solid-state titanium:sapphire laser systems has nowadays initiated a significant evolution within this field. In this paper an overview of the ongoing developments will be given, which have contributed to the establishment of a number of new laser ion source facilities worldwide during the last five years.

  12. On-Line Metrology with Conoscopic Holography: Beyond Triangulation

    Directory of Open Access Journals (Sweden)

    Ignacio Álvarez

    2009-09-01

    Full Text Available On-line non-contact surface inspection with high precision is still an open problem. Laser triangulation techniques are the most common solution for this kind of systems, but there exist fundamental limitations to their applicability when high precisions, long standoffs or large apertures are needed, and when there are difficult operating conditions. Other methods are, in general, not applicable in hostile environments or inadequate for on-line measurement. In this paper we review the latest research in Conoscopic Holography, an interferometric technique that has been applied successfully in this kind of applications, ranging from submicrometric roughness measurements, to long standoff sensors for surface defect detection in steel at high temperatures.

  13. Optimization of dynamic-microwave assisted enzymatic hydrolysis extraction of total ginsenosides from stems and leaves of panax ginseng by response surface methodology.

    Science.gov (United States)

    Wang, Xiao-Yan; Ren, Hui

    2018-03-21

    Ginseng stems and leaves (GSAL) are abundant in ginsenosides compounds. For efficient utilization of GSAL and the enhancement of total ginsenosides (TG) compound yields in GSAL, TG from GSAL were extracted, using dynamic-microwave assisted extraction coupled with enzymatic hydrolysis (DMAE-EH) method. The extraction process has been simulated and its main influencing factors such as ethanol concentration, microwave temperature, microwave time and pump flow rate have been optimized by response surface methodology coupled with a Box-Behnken design(BBD). The experimental results indicated that optimal extraction conditions of TG from GSAL were as follows: ethanol concentration of 75%, microwave temperature of 60°C, microwave time of 20 min and pump flow rate of 38 r/min. After experimental verification, the experimental yields of TG was 60.62 ± 0.85 mg g -1 , which were well agreement with the predicted by the model. In general, the present results demonstrated that DMAE-EH method was successfully used to extract total ginsenosides in GSAL.

  14. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Science.gov (United States)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  15. A Comparison of Multiscale Permutation Entropy Measures in On-Line Depth of Anesthesia Monitoring.

    Science.gov (United States)

    Su, Cui; Liang, Zhenhu; Li, Xiaoli; Li, Duan; Li, Yongwang; Ursino, Mauro

    2016-01-01

    Multiscale permutation entropy (MSPE) is becoming an interesting tool to explore neurophysiological mechanisms in recent years. In this study, six MSPE measures were proposed for on-line depth of anesthesia (DoA) monitoring to quantify the anesthetic effect on the real-time EEG recordings. The performance of these measures in describing the transient characters of simulated neural populations and clinical anesthesia EEG were evaluated and compared. Six MSPE algorithms-derived from Shannon permutation entropy (SPE), Renyi permutation entropy (RPE) and Tsallis permutation entropy (TPE) combined with the decomposition procedures of coarse-graining (CG) method and moving average (MA) analysis-were studied. A thalamo-cortical neural mass model (TCNMM) was used to generate noise-free EEG under anesthesia to quantitatively assess the robustness of each MSPE measure against noise. Then, the clinical anesthesia EEG recordings from 20 patients were analyzed with these measures. To validate their effectiveness, the ability of six measures were compared in terms of tracking the dynamical changes in EEG data and the performance in state discrimination. The Pearson correlation coefficient (R) was used to assess the relationship among MSPE measures. CG-based MSPEs failed in on-line DoA monitoring at multiscale analysis. In on-line EEG analysis, the MA-based MSPE measures at 5 decomposed scales could track the transient changes of EEG recordings and statistically distinguish the awake state, unconsciousness and recovery of consciousness (RoC) state significantly. Compared to single-scale SPE and RPE, MSPEs had better anti-noise ability and MA-RPE at scale 5 performed best in this aspect. MA-TPE outperformed other measures with faster tracking speed of the loss of unconsciousness. MA-based multiscale permutation entropies have the potential for on-line anesthesia EEG analysis with its simple computation and sensitivity to drug effect changes. CG-based multiscale permutation

  16. Recovery Strategies in On-Line Service Failure

    OpenAIRE

    Ozuem, Wilson; Lancaster, Geoff

    2013-01-01

    Despite a proliferation of a number of studies on service failures and recovery in e-service settings, there is a paucity of knowledge of ways in which service failures and recovery practices are implemented in the fashion industry. Drawing on constructivist perspective, this study offers a new perspective on an effective relational mechanism that would bridge the rupture between consumers and companies particularly in the on-line fashion sector. The analysis adds to studies on service failur...

  17. Understanding Cognitive Load Using On-line Dictionaries

    OpenAIRE

    Robert F. , Dilenschneider

    2017-01-01

    Cognitive Load Theory may useful for language instructors to understand how the look up conditions ofusing an on-line dictionary might influence learning. This paper first reviews previous studies that haveinvestigated dictionary use for vocabulary acquisition and reading comprehension Second, it explainsthe various elements of Cognitive Load Theory. Third, it describes how Cognitive Load Theory appliesto language learners' to learn unknown words and comprehend texts Last, it discusses the pe...

  18. On-line diagnostics for a real time system

    International Nuclear Information System (INIS)

    Sreenivasan, P.

    1976-01-01

    The purpose of an on-line diagnostics is to infuse the ability of self diagnosing in an online computer to enhance its dependability in a real time system. Such a diagnostics evolved for the CDPS of the Fast Breeder Test Reactor at Kalpakkam is reported. The two phases of the diagnostics, i.e., the malfunction detection and post detection action are described in some detail. (A.K.)

  19. Isocele I, the Orsay synchrocyclotron on-line separator

    International Nuclear Information System (INIS)

    Caruette, A.; Ferro, A.; Foucher, R.

    1976-01-01

    The main characteristics of the isotope separator Isocele 1 are described. This medium current separator was on line with the Orsay synchrocyclotron (155 MeV p, or 210 MeV 3 He) from March 1974 up to May 1975. Results obtained with different targets (Au, Bi, Er, Pt, Sn, Th) are summarized. They confirm the efficiency of medium current separators of this type [fr

  20. A decision support system for on-line leakage localization

    OpenAIRE

    Meseguer, Jordi; Mirats-Tur, Josep M.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Pérez, Ramon; Sanz, Gerard; Ibarra, David

    2014-01-01

    This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integr...

  1. On-line production of [11C]cyanogen bromide

    International Nuclear Information System (INIS)

    Westerberg, G.; Laangstroem, B.

    1997-01-01

    The electrophilic labelling precursor [ 11 C]cyanogen bromide was produced in 95% radiochemical yield (decay-corrected) from hydrogen [ 11 C]cyanide within 3 min from the end of bombardment using a simple and convenient solid-phase on-line procedure. The [ 11 C]cyanogen bromide has been used in the synthesis of a number of labelled compounds for use in positron emission tomography. (author)

  2. On-line Monitoring System for Power Transformers

    Directory of Open Access Journals (Sweden)

    Alexandru HOTEA

    2016-12-01

    Full Text Available Power transformers are the most important and expensive equipment from the electricity transmission system, so it is very important to know the real state of health of such equipment in every moment. De-energizing the power transformer accidentally due to internal defects can generate high costs. Annual maintenance proved to be ineffective in many cases to determine the internal condition of the equipment degradation due to faults rapidly evolving. An On-line Monitoring System for Power Transformers help real-time condition assessment and to detect errors early enough to take action to eliminate or minimize them. After abnormality detected, it is still important to perform full diagnostic tests to determine the exact condition of the equipment. On-line monitoring systems can help increase the level of availability and reliability of power transformers and lower costs of accidental interruption. This paper presents cases studies on several power transformers equipped with on-line monitoring systems from Transelectrica substation.

  3. Characterizing chemical systems with on-line computers and graphics

    International Nuclear Information System (INIS)

    Frazer, J.W.; Rigdon, L.P.; Brand, H.R.; Pomernacki, C.L.

    1979-01-01

    Incorporating computers and graphics on-line to chemical experiments and processes opens up new opportunities for the study and control of complex systems. Systems having many variables can be characterized even when the variable interactions are nonlinear, and the system cannot a priori be represented by numerical methods and models. That is, large sets of accurate data can be rapidly acquired, then modeling and graphic techniques can be used to obtain partial interpretation plus design of further experimentation. The experimenter can thus comparatively quickly iterate between experimentation and modeling to obtain a final solution. We have designed and characterized a versatile computer-controlled apparatus for chemical research, which incorporates on-line instrumentation and graphics. It can be used to determine the mechanism of enzyme-induced reactions or to optimize analytical methods. The apparatus can also be operated as a pilot plant to design control strategies. On-line graphics were used to display conventional plots used by biochemists and three-dimensional response-surface plots

  4. On-Line Fringe Tracking and Prediction at IOTA

    Science.gov (United States)

    Wilson, Edward; Mah, Robert; Lau, Sonie (Technical Monitor)

    1999-01-01

    The Infrared/Optical Telescope Array (IOTA) is a multi-aperture Michelson interferometer located on Mt. Hopkins near Tucson, Arizona. To enable viewing of fainter targets, an on-line fringe tracking system is presently under development at NASA Ames Research Center. The system has been developed off-line using actual data from IOTA, and is presently undergoing on-line implementation at IOTA. The system has two parts: (1) a fringe tracking system that identifies the center of a fringe packet by fitting a parametric model to the data; and (2) a fringe packet motion prediction system that uses characteristics of past fringe packets to predict fringe packet motion. Combined, this information will be used to optimize on-line the scanning trajectory, resulting in improved visibility of faint targets. Fringe packet identification is highly accurate and robust (99% of the 4000 fringe packets were identified correctly, the remaining 1% were either out of the scan range or too noisy to be seen) and is performed in 30-90 milliseconds on a Pentium II-based computer. Fringe packet prediction, currently performed using an adaptive linear predictor, delivers a 10% improvement over the baseline of predicting no motion.

  5. Review of trigger and on-line processors at SLAC

    International Nuclear Information System (INIS)

    Lankford, A.J.

    1984-07-01

    The role of trigger and on-line processors in reducing data rates to manageable proportions in e + e - physics experiments is defined not by high physics or background rates, but by the large event sizes of the general-purpose detectors employed. The rate of e + e - annihilation is low, and backgrounds are not high; yet the number of physics processes which can be studied is vast and varied. This paper begins by briefly describing the role of trigger processors in the e + e - context. The usual flow of the trigger decision process is illustrated with selected examples of SLAC trigger processing. The features are mentioned of triggering at the SLC and the trigger processing plans of the two SLC detectors: The Mark II and the SLD. The most common on-line processors at SLAC, the BADC, the SLAC Scanner Processor, the SLAC FASTBUS Controller, and the VAX CAMAC Channel, are discussed. Uses of the 168/E, 3081/E, and FASTBUS VAX processors are mentioned. The manner in which these processors are interfaced and the function they serve on line is described. Finally, the accelerator control system for the SLC is outlined. This paper is a survey in nature, and hence, relies heavily upon references to previous publications for detailed description of work mentioned here. 27 references, 9 figures, 1 table

  6. On-line plant-wide monitoring using neural networks

    International Nuclear Information System (INIS)

    Turkcan, E.; Ciftcioglu, O.; Eryurek, E.; Upadhyaya, B.R.

    1992-06-01

    The on-line signal analysis system designed for a multi-level mode operation using neural networks is described. The system is capable of monitoring the plant states by tracking different number of signals up to 32 simultaneously. The data used for this study were acquired from the Borssele Nuclear Power Plant (PWR type), and using the on-line monitoring system. An on-line plant-wide monitoring study using a multilayer neural network model is discussed in this paper. The back-propagation neural network algorithm is used for training the network. The technique assumes that each physical state of the power plant can be represented by a unique pattern of instrument readings which can be related to the condition of the plant. When disturbance occurs, the sensor readings undergo a transient, and form a different set of patterns which represent the new operational status. Diagnosing these patterns can be helpful in identifying this new state of the power plant. To this end, plant-wide monitoring with neutral networks is one of the new techniques in real-time applications. (author). 9 refs.; 5 figs

  7. Designing effective on-line continuing medical education.

    Science.gov (United States)

    Zimitat, Craig

    2001-03-01

    The Internet, and new information and communication technologies available through the Internet, provides medical educators with an opportunity to develop unique on-line learning environments with real potential to improve physicians' knowledge and effect change in their clinical practice. There are approximately 100 websites offering on-line CME courses in the USA alone. However, few of these CME courses appear to be based on sound educational principles or CME research and may have little chance of achieving the broader goals of CME. The majority of these courses closely resemble their traditional counterparts (e.g. paper-based books are now electronic books) and appear to be mere substitutions for old-technology CME resources. Whilst some CME providers add unique features of the Internet to enrich their websites, they do not employ strategies to optimize the learning opportunities afforded by this new technology. The adoption of adult learning principles, reflective practice and problem-based approaches can be used as a foundation for sound CME course design. In addition, knowledge of Internet technology and the learning opportunities it affords, together with strategies to maintain participation and new assessment paradigms, are all needed for developing online CME. We argue for an evidence-based and strategic approach to the development of on-line CME courses designed to enhance physician learning and facilitate change in clinical behaviour.

  8. On-line radiation teaching materials using IT technology

    International Nuclear Information System (INIS)

    Inoue, Hiroyoshi

    2005-01-01

    We developed the on-line radiation teaching materials using the Internet, in order to provide the teaching support materials of atomic power and radiation educations in on-school study, as well as to create the complementary study system in off-school study. The themes of teaching materials were selected from requests by teachers. In the case of an elementary school, the teaching material 'an environmental problem and atomic power' was created as the aggregate of each content for study without boundary between subjects. The teaching material 'medical treatment and radiation' was created for junior high school students to raise the individual knowledge. In the case of a high school, the teaching material nucleus and radiation' was prepared to supplement the physical study of students. The on-line teaching materials were tried to 300 junior high school and high school students, 68% of students answered that the teaching material is effective to understand atomic power and radiation, though 17% answered they were not effective. Although there are problems to prepare IT learning equipments and learning follow-up system in the material, it is suggested that the on-line teaching materials will provide the novel learning system including debates for the study. This method has no limitation of time and place. (author)

  9. On-line fouling monitor for heat exchangers

    International Nuclear Information System (INIS)

    Tsou, J.L.

    1995-01-01

    Biological and/or chemical fouling in utility service water system heat exchangers adversely affects operation and maintenance costs, and reduced heat transfer capability can force a power deaerating or even a plant shut down. In addition, service water heat exchanger performance is a safety issue for nuclear power plants, and the issue was highlighted by NRC in Generic Letter 89-13. Heat transfer losses due to fouling are difficult to measure and, usually, quantitative assessment of the impact of fouling is impossible. Plant operators typically measure inlet and outlet water temperatures and flow rates and then perform complex calculations for heat exchanger fouling resistance or ''cleanliness''. These direct estimates are often imprecise due to inadequate instrumentation. Electric Power Research Institute developed and patented an on-line condenser fouling monitor. This monitor may be installed in any location within the condenser; does not interfere with routine plant operations, including on-line mechanical and chemical treatment methods; and provides continuous, real-time readings of the heat transfer efficiency of the instrumented tube. This instrument can be modified to perform on-line monitoring of service water heat exchangers. This paper discusses the design, construction of the new monitor, and algorithm used to calculate service water heat exchanger fouling

  10. Denmark's on - line early warning radiation monitoring network

    International Nuclear Information System (INIS)

    Walmod-Larsen, O.; Lippert, J.

    1990-01-01

    In Denmark an emergency response coordination committee was set up to cope with the problems after the Chernobyl accident with participation of all relevant authorities. For help in an emergency situation the ARGOS (Accident Reporting and Guiding Operational System), system will be put into use. The ARGOS emergency evaluation computer system, which has been developed in cooperation with the Danish Environmental Protection Agency, is in operation in connection with the emergency planning for the east region of Denmark with regard to the Swedish nuclear power plant operating at Barseback. Inputs of measurement data are on-line available on data screens for evaluation in the emergency coordination centers, presented on suitable geographical maps, showing iso-contours calculated from the input. In case of an alert situation other systems can be put in operation, f.ex. mobile measuring units from the CDEPA's local, operational emergency centers. Their readings can then be put into the computing system parallel to the on-line stations and be presented by the ARGOS-system for evaluation in the emergency command centers. If another national authority in an alert situation requests a transfer of measurement data, and if this is agreed upon by the competent Danish authority, then the transfer can be arranged from the ARGOS-system, through agreed transmission channels. At present the ARGOS system is being improved and expanded by RNL to cover the whole Danish region and to present measurements from the on-line warning system

  11. Automated mass spectrometric analysis of urinary free catecholamines using on-line solid phase extraction

    NARCIS (Netherlands)

    de Jong, Wilhelmina H. A.; de Vries, Elisabeth G. E.; Wolffenbuttel, Bruce H. R.; Kema, I. P.

    2010-01-01

    Analysis of catecholamines (epinephrine, norepinephrine and dopamine) in plasma and urine is used for diagnosis and treatment of catecholamine-producing tumors Current analytical techniques for catecholamine quantification are laborious, time-consuming and technically demanding Our aim was to

  12. On-Line Monitoring for Process Control and Safeguarding of Radiochemical Streams at Spent Fuel Reprocessing Plants

    International Nuclear Information System (INIS)

    Bryan, S.; Levitskaia, T.; Casella, A.

    2015-01-01

    The International Atomic Energy Agency (IAEA) has established international safe- guards standards for fissionable material at spent nuclear fuel reprocessing plants to ensure that significant quantities of weapons-grade nuclear material are not diverted from these facilities. Currently, methods to verify material control and accountancy (MC&A) at these facilities require time-consuming and resource-intensive destructive assay (DA). Leveraging new on-line non-destructive assay (NDA) techniques in conjunction with the traditional and highly precise DA methods may provide a more timely, cost-effective and resource-efficient means for MC&A verification at such facilities. Pacific Northwest National Laboratory (PNNL) is developing on-line NDA process monitoring technologies, including a spectroscopy-based monitoring system, to potentially reduce the time and re- source burden associated with current techniques. The spectroscopic monitor continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major cold flowsheet chemicals using ultra-violet and visible, near infrared and Raman spectroscopy. This paper will provide an overview of the methods and report our on-going efforts to develop and demonstrate the technologies. Our ability to identify material intentionally diverted from a liquid-liquid solvent extraction contactor system was successfully tested using on-line process monitoring as a means to detect the amount of material diverted. A chemical diversion, and detection of that diversion, from a solvent extraction scheme was demonstrated using a centrifugal contactor system operating with the PUREX flowsheet. A portion of the feed from a counter-current extraction system was diverted while a continuous extraction experiment was underway. The amount observed to be diverted by on-line spectroscopic process monitoring was in excellent agreement with values based from the known mass of

  13. Analysis of flavonoids from propolis by on-line HPLC-electrospray mass spectrometry.

    Science.gov (United States)

    Volpi, Nicola; Bergonzini, Gianluca

    2006-09-26

    In this paper, the qualitative and quantitative separation and determination of the polyphenolic component of propolis preparations in the form of ethanolic extract, usually used for commercial pharmaceutical preparations, has been investigated by means of on-line HPLC-ESI/MS technique. Propolis of different origin have been evaluated for their components and a specific fingerprint has been determined potentially useful for the quality control of extracts in pharmaceutical preparations. The ethanolic extracts of propolis from Argentina, Italy and Spain shows approximately the same total ion chromatogram (TIC) profile due to the presence of the same molecular species, identified by the negative ESI-MS. On the contrary, the samples from Azerbaijan, China, Ethiopia and Kenya show a very peculiar TIC profiles. By using many purified flavonoids and calibration curves over a wide concentration range, from 0.05 (5 microg/ml) to 5 microg (500 microg/ml), an accurate assessment of the contents of several bioactive compounds in extract samples was performed. The propolis from Argentina, Italy and Spain show a great amount of pinocembrin (approximately 49%, 48% and 39% of the total identified flavonoids, respectively) and variable but similar percentages of the other species. On the contrary, the propolis from China, Azerbaijan and Ethiopia have a great amount of pinocembrin (approximately 63%, 46% and 62%, respectively) but no presence of genistein, kaempferol, apigenin and chrysin for the sample from China, genistein, kaempferol, acacetin and chrysin for the propolis from Azerbaijan, and no kaempferol and acacetin for the sample from Ethiopia. The ethanolic extract from propolis of Kenya has no identified flavonoid species but just a peak possessing a m/z of 253.0. Finally, an evaluation of the presence of total flavonoids for the various propolis samples was performed, with extracts from Argentina, Italy and Spain more rich in polyphenols than those from Azerbaijan, China

  14. Expert System Development on On-line Measurement of Sewage Treatment Based Process

    Directory of Open Access Journals (Sweden)

    Jianjun QIN

    2014-02-01

    Full Text Available This article puts forward a solution in which an instrument on-line automatic measurement and expert system process are optimized according to the complexity and great process dynamics of sewage treatment process. Firstly modeling has been set up with configuration sewage treatment process in which the process has been integrated into the computer software environment. Secondly certain number of water quality automatic monitoring instruments and sensor probes are set in the reaction tanks according to the needs of process changes and management. The data information acquired can be displayed and recorded at the real time. A human-machine integration expert system featuring computer automation management is developed for the base by one-off method thus to realize the intelligent and unmanned management. The advantages brought about from it can fill up the inexperience of the on-site management personnel and solve the contradiction between the water quality dynamics and difficulty in the process adjustment.

  15. In the Jungle of Astronomical On--line Data Services

    Science.gov (United States)

    Egret, D.

    The author tried to survive in the jungle of astronomical on--line data services. In order to find efficient answers to common scientific data retrieval requests, he had to collect many pieces of information, in order to formulate typical user scenarios, and try them against a number of different data bases, catalogue services, or information systems. He discovered soon how frustrating treasure coffers may be when their keys are not available, but he realized also that nice widgets and gadgets are of no help when the information is not there. And, before long, he knew he would have to navigate through several systems because no one was yet offering a general answer to all his questions. I will present examples of common user scenarios and show how they were tested against a number of services. I will propose some elements of classification which should help the end-user to evaluate how adequate the different services may be for providing satisfying answers to specific queries. For that, many aspects of the user interaction will be considered: documentation, access, query formulation, functionalities, qualification of the data, overall efficiency, etc. I will also suggest possible improvements to the present situation: the first of them being to encourage system managers to increase collaboration between one another, for the benefit of the whole astronomical community. The subjective review I will present, is based on publicly available astronomical on--line services from the U.S. and from Europe, most of which (excepting the newcomers) were described in ``Databases and On-Line Data in Astronomy", (Albrecht & Egret, eds, 1991): this includes databases (such as NED and Simbad ), catalog services ( StarCat , DIRA , XCatScan , etc.), and information systems ( ADS and ESIS ).

  16. On-line implant reconstruction in HDR brachytherapy

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Kruijf, Wilhelmus J.M. de; Levendag, Peter C.

    2006-01-01

    Background and purpose: To evaluate the accuracy of on-line planning in an Integrated Brachytherapy Unit (IBU) using dedicated image distortion correction algorithms, correcting the geometric distortion and magnetic distortion separately, and to determine the effect of the reconstruction accuracy on clinical treatment plans in terms of deviations in treatment time and dose. Patients and methods: The reconstruction accuracy has been measured using 20 markers, positioned at well known locations in a QA phantom. Treatment plans of two phantoms representing clinical implant geometries, have been compared with reference plans to determine the effect of the reconstruction accuracy on the treatment plan. Before clinical introduction, treatment plans of three representative patients, based on on-line reconstruction, have been compared with reference plans. Results: The average reconstruction error for 10 in. images reduces from -0.6 mm (range -2.6 to +1.0 mm) to -0.2 mm (range -1.2 to +0.6 mm) after image distortion correction and for 15 in. images from 0.8 mm (range -0.5 to +3.0 mm) to 0.0 mm (range -0.8 to +0.8 mm). The error in case of eccentric positioning of the phantom, i.e. 0.8 mm (range -1.0 to +3.3 mm), reduces to 0.1 mm (range -0.5 to +0.9 mm). Correction of the image distortions reduces the deviation in the calculated treatment time of maximally 2.7% to less than 0.8% in case of eccentrically positioned clinical phantoms. The deviation in the treatment time or reference dose in the plans based on on-line reconstruction with image distortion correction of the three patient examples is smaller than 0.3%. Conclusions: Accurate on-line implant reconstruction using the IBU localiser and dedicated correction algorithms separating the geometric distortion and the magnetic distortion is possible. The results fulfill the minimum requirements as imposed by the Netherlands Commission on Radiation Dosimetry (NCS) without limitations regarding the usable range of the field

  17. On-line data processing for scintillation camera

    International Nuclear Information System (INIS)

    Ueyanagi, Hideo

    1974-01-01

    To process on-line the information from scintillation cameras, the computing/processing device of wired program type, with a specialized mini-computer for the processing, is generally used; and by this method, the data processing is done by the users of scintillation cameras. In the device with a mini-computer with processing programming by software, the almost all items in processing can be executed; but the operation requires some skill. With mini-computer operation, on the other hand, there are the problems of data-point number, process-time reduction, and image storage for both long and short terms. (Mori, K.)

  18. Robust Control Methods for On-Line Statistical Learning

    Directory of Open Access Journals (Sweden)

    Capobianco Enrico

    2001-01-01

    Full Text Available The issue of controlling that data processing in an experiment results not affected by the presence of outliers is relevant for statistical control and learning studies. Learning schemes should thus be tested for their capacity of handling outliers in the observed training set so to achieve reliable estimates with respect to the crucial bias and variance aspects. We describe possible ways of endowing neural networks with statistically robust properties by defining feasible error criteria. It is convenient to cast neural nets in state space representations and apply both Kalman filter and stochastic approximation procedures in order to suggest statistically robustified solutions for on-line learning.

  19. Development of an on-line radon monitoring system

    International Nuclear Information System (INIS)

    Guo Huiping; Shang Aiguo; Liu Junfeng; Zhou Chunlin; Di Yuming

    2004-01-01

    Of the actual demand by the strategic missile troops, the author has successfully developed a specially designed passive diffusion collecting chamber to collect the decay products of radon by high voltage static electricity, and using the single-chip microcomputer to reckon the radon concentration in air, which is actually a portable, continuous and automatic on-line monitoring instrument. It was made into a four-slot standard plug-in board of a NIM, and it functions as auto data memory, data process, display, over-threshold alarming and so on. (authors)

  20. Integrated on-line accelerator modeling at CEBAF

    International Nuclear Information System (INIS)

    Bowling, B.A.; Shoaee, H.; Van Zeijts, J.; Witherspoon, S.; Watson, W.

    1995-01-01

    An on-line accelerator modeling facility is currently under development at CEBAF. The model server, which is integrated with the EPICS control system, provides coupled and 2nd-order matrices for the entire accelerator, and forms the foundation for automated model- based control and diagnostic applications. Four types of machine models are provided, including design, golden or certified, live, and scratch or simulated model. Provisions are also made for the use of multiple lattice modeling programs such as DIMAD, PARMELA, and TLIE. Design and implementation details are discussed. 2 refs., 4 figs

  1. Enhancing Learner Autonomy in an On-line Editing Programme

    Directory of Open Access Journals (Sweden)

    Hebe Wong

    2011-09-01

    Full Text Available Little (1999 argues that in formal educational contexts, “the basis of learner autonomy is acceptance of responsibility for one’s own learning” (p.11. An autonomous learner takes responsibility for various aspects of learning (Benson & Voller, 1997; Holec, 1981. This study examines how learner autonomy opportunities were provided at various stages of writing in an on-line editing programme for a group of electronic engineering students and how the students took charge of their language learning when receiving feedback on their technical writing. The impact on their own learning effectiveness of the decisions students made is also discussed.

  2. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2007-12-01

    (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  3. On-line core monitoring with CORE MASTER / PRESTO

    International Nuclear Information System (INIS)

    Lindahl, S.O.; Borresen, S.; Ovrum, S.

    1986-01-01

    Advanced calculational tools are instrumental in improving reactor plant capacity factors and fuel utilization. The computer code package CORE MASTER is an integrated system designed to achieve this objective. The system covers all main activities in the area of in-core fuel management for boiling water reactors; design, operation support, and on-line core monitoring. CORE MASTER operates on a common data base, which defines the reactor and documents the operating history of the core and of all fuel bundles ever used

  4. Core on-line monitoring and computerized procedures systems

    International Nuclear Information System (INIS)

    Gangloff, W.C.

    1986-01-01

    The availability of operating nuclear power plants has been affected significantly by the difficulty people have in coping with the complexity of the plants and the operating procedures. Two ways to use modern computer technology to ease the burden of coping are discussed in this paper, an on-line core monitoring system with predictive capability and a computerized procedures system using live plant data. These systems reduce human errors by presenting information rather than simply data, using the computer to manipulate the data, but leaving the decisions to the plant operator

  5. Lower Bounds and Semi On-line Multiprocessor Scheduling

    Directory of Open Access Journals (Sweden)

    T.C. Edwin Cheng

    2003-10-01

    Full Text Available We are given a set of identical machines and a sequence of jobs from which we know the sum of the job weights in advance. The jobs have to be assigned on-line to one of the machines and the objective is to minimize the makespan. An algorithm with performance ratio 1.6 and a lower bound of 1.5 is presented. This improves recent results by Azar and Regev who published an algorithm with performance ratio 1.625 for the less general problem that the optimal makespan is known in advance.

  6. Adaptive calibration method with on-line growing complexity

    Directory of Open Access Journals (Sweden)

    Šika Z.

    2011-12-01

    Full Text Available This paper describes a modified variant of a kinematical calibration algorithm. In the beginning, a brief review of the calibration algorithm and its simple modification are described. As the described calibration modification uses some ideas used by the Lolimot algorithm, the algorithm is described and explained. Main topic of this paper is a description of a synthesis of the Lolimot-based calibration that leads to an adaptive algorithm with an on-line growing complexity. The paper contains a comparison of simple examples results and a discussion. A note about future research topics is also included.

  7. NNDC [National Nuclear Data Center] on-line services documentation

    International Nuclear Information System (INIS)

    Dunford, C.L.; Burrows, T.W.; Tuli, J.K.

    1987-01-01

    This document summarizes and describes how to access the on-line services available from the National Nuclear Data Center (NNDC) located at Brookhaven National Laboratory. The services are available free of cost to US Department of Energy, its contractors and others who support the NNDC or supply data to the NNDC. Four of the center's data bases are now accessible to non-NNDC scientists via remote connection to the center's VAX 11/780. To use this service, you must have a terminal with access by either a telephone line or the PHYSNET network. A VT100 terminal or a terminal with VT-100 emulation is recommended but not required

  8. Efficient and Secure Comparison for On-Line Auctions

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Krøigaard, Mikkel; Geisler, Martin Joakim

    2007-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption. We also propose a homomorphic encryption scheme that can be used in our protocol and makes it more efficient than previous solutions. Our protocol is well-suited for application in on-line auctions, both...... with respect to functionality and performance. It minimizes the amount of information bidders need to send, and for comparison of 16 bit numbers with security based on 1024 bit RSA (executed by two parties), our implementation takes 0.28 seconds including all computation and communication. Using precomputation...

  9. On-line computing in a classified environment

    International Nuclear Information System (INIS)

    O'Callaghan, P.B.

    1982-01-01

    Westinghouse Hanford Company (WHC) recently developed a Department of Energy (DOE) approved real-time, on-line computer system to control nuclear material. The system simultaneously processes both classified and unclassified information. Implementation of this system required application of many security techniques. The system has a secure, but user friendly interface. Many software applications protect the integrity of the data base from malevolent or accidental errors. Programming practices ensure the integrity of the computer system software. The audit trail and the reports generation capability record user actions and status of the nuclear material inventory

  10. On-line fatigue monitoring and margins probabilistic assessment

    International Nuclear Information System (INIS)

    Fournier, I.; Morilhat, P.

    1993-01-01

    An on-line computer aided system has been developed by Electricite de France, the French utility, for a fatigue monitoring of critical locations in the nuclear steam supply system. This tool, called fatiguemeter, includes as input data only existing plant parameters and is based on some conservative assumptions at several steps of the damage assessment (thermal boundary conditions, stress computation...). This paper presents recent developments performed toward a better assessing of margins involved in the complete analysis. The methodology is enlightened with an example showing the influence of plant parameters incertitude on the final stress computed at a PWR 900 MW unit pressurizer surge line nozzle. (author)

  11. On-line system for investigation of atomic structure

    International Nuclear Information System (INIS)

    Amus'ya, M.Ya.; Chernysheva, L.V.

    1983-01-01

    A description of the on-line ATOM system is presented that enables to investigate the structure of atomic electron shells and their interactions with different scattering particles-electrons, positronse photons, mesons - with the use of computerized numerical solutions. The problem is stated along with mathematical description of atomic properties including theoretical and numerical models for each investigated physical process. The ATOM system structure is considered. The Hartree-Fock method is used to determine the wave functions of the ground and excited atomic states. The programs are written in the ALGOL langauge. Different atomic characteristics were possible to be calculated for the first time with an accuracy exceeding an experimental one

  12. ELT-MELAS analyzer and its on-line programs

    International Nuclear Information System (INIS)

    Anikeev, V.B.; Berezhnoj, V.A.; Glupova

    1976-01-01

    ELT-MELAS device constructed for an automatic analysis of pictures from big bubble chambers is described. It is controlled by a medium-size ICL-1903A computer and has two measuring modes: analysis of the ''agreement'' signal and digitation of slice-scans. Main features of the hardware and of on-line controlling and diagnostic software are presented. The test results of the MELAS complex as well as preliminary results of the scan-slice measurements of pictures from 15sup(') chamber are given

  13. Molecular dynamics simulations of hydrophobous ions at the liquid-liquid interfaces: case of dicarbollide anions as synergy agents and of ionic liquids as extracting medium

    International Nuclear Information System (INIS)

    Chevrot, G.

    2008-01-01

    Based on molecular dynamics simulations, we first describe the distribution of dicarbollide salts (CCD - , Mn + ) in concentrated monophasic solutions (water, chloroform, octanol, nitrobenzene) and in the corresponding biphasic 'oil' - water solutions. We point to the importance of surface activity of the CCD - s and of their self-aggregation in water, with marked counterions effects, and we explain the synergistic effect of CCD - s in the Eu 3+ extraction by BTP ligands. In the second part of the thesis we report exploratory simulations on the extraction of Sr 2+ by 18-crown-6 to an hydrophobic ionic liquid ([BMI][PF6]), focusing on the liquid - liquid interface. Analogies and differences with a classical aqueous interface are outlined. (author)

  14. Development of new on-line statistical program for the Korean Society for Radiation Oncology.

    Science.gov (United States)

    Song, Si Yeol; Ahn, Seung Do; Chung, Weon Kuu; Shin, Kyung Hwan; Choi, Eun Kyung; Cho, Kwan Ho

    2015-06-01

    To develop new on-line statistical program for the Korean Society for Radiation Oncology (KOSRO) to collect and extract medical data in radiation oncology more efficiently. The statistical program is a web-based program. The directory was placed in a sub-folder of the homepage of KOSRO and its web address is http://www.kosro.or.kr/asda. The operating systems server is Linux and the webserver is the Apache HTTP server. For database (DB) server, MySQL is adopted and dedicated scripting language is the PHP. Each ID and password are controlled independently and all screen pages for data input or analysis are made to be friendly to users. Scroll-down menu is actively used for the convenience of user and the consistence of data analysis. Year of data is one of top categories and main topics include human resource, equipment, clinical statistics, specialized treatment and research achievement. Each topic or category has several subcategorized topics. Real-time on-line report of analysis is produced immediately after entering each data and the administrator is able to monitor status of data input of each hospital. Backup of data as spread sheets can be accessed by the administrator and be used for academic works by any members of the KOSRO. The new on-line statistical program was developed to collect data from nationwide departments of radiation oncology. Intuitive screen and consistent input structure are expected to promote entering data of member hospitals and annual statistics should be a cornerstone of advance in radiation oncology.

  15. Development of new on line statistical program for the Korean society for radiation oncology

    International Nuclear Information System (INIS)

    Song, Si Yeol; Ahn, Seung Do; Choi, Eun Kyung; Chung, Weon Kuu; Shin, Kyung Hwan; Cho, Kwan Ho

    2015-01-01

    To develop new on-line statistical program for the Korean Society for Radiation Oncology (KOSRO) to collect and extract medical data in radiation oncology more efficiently. The statistical program is a web-based program. The directory was placed in a sub-folder of the homepage of KOSRO and its web address is http://www.kosro.or.kr/asda. The operating systems server is Linux and the webserver is the Apache HTTP server. For database (DB) server, MySQL is adopted and dedicated scripting language is the PHP. Each ID and password are controlled independently and all screen pages for data input or analysis are made to be friendly to users. Scroll-down menu is actively used for the convenience of user and the consistence of data analysis. Year of data is one of top categories and main topics include human resource, equipment, clinical statistics, specialized treatment and research achievement. Each topic or category has several subcategorized topics. Real-time on-line report of analysis is produced immediately after entering each data and the administrator is able to monitor status of data input of each hospital. Backup of data as spread sheets can be accessed by the administrator and be used for academic works by any members of the KOSRO. The new on-line statistical program was developed to collect data from nationwide departments of radiation oncology. Intuitive screen and consistent input structure are expected to promote entering data of member hospitals and annual statistics should be a cornerstone of advance in radiation oncology

  16. Development of new on line statistical program for the Korean society for radiation oncology

    Energy Technology Data Exchange (ETDEWEB)

    Song, Si Yeol; Ahn, Seung Do; Choi, Eun Kyung [Dept. of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Chung, Weon Kuu [Dept. of Radiation Oncology, Kyung Hee University Hospital at Kangdong, Kyung Hee University School of Medicine, Seoul (Korea, Republic of); Shin, Kyung Hwan [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cho, Kwan Ho [Dept. of Radiation Oncology, Proton Therapy Center, National Cancer Center Hospital, Goyang (Korea, Republic of)

    2015-06-15

    To develop new on-line statistical program for the Korean Society for Radiation Oncology (KOSRO) to collect and extract medical data in radiation oncology more efficiently. The statistical program is a web-based program. The directory was placed in a sub-folder of the homepage of KOSRO and its web address is http://www.kosro.or.kr/asda. The operating systems server is Linux and the webserver is the Apache HTTP server. For database (DB) server, MySQL is adopted and dedicated scripting language is the PHP. Each ID and password are controlled independently and all screen pages for data input or analysis are made to be friendly to users. Scroll-down menu is actively used for the convenience of user and the consistence of data analysis. Year of data is one of top categories and main topics include human resource, equipment, clinical statistics, specialized treatment and research achievement. Each topic or category has several subcategorized topics. Real-time on-line report of analysis is produced immediately after entering each data and the administrator is able to monitor status of data input of each hospital. Backup of data as spread sheets can be accessed by the administrator and be used for academic works by any members of the KOSRO. The new on-line statistical program was developed to collect data from nationwide departments of radiation oncology. Intuitive screen and consistent input structure are expected to promote entering data of member hospitals and annual statistics should be a cornerstone of advance in radiation oncology.

  17. Utilities enticing customers to come on-line

    International Nuclear Information System (INIS)

    Anon

    2000-01-01

    The first tentative steps by electric utilities to offer customer services on-line is reported. While most of the on-line communications to date has been merely to present information about products and services, at least a few utilities, -- Newfoundland Power being one of them -- are now offering customers the opportunity to check on their account status, to make inquiries, and on a voluntary basis employees of the utility can receive their bills on the web. BC Hydro is even more advanced; it has offered a similar service since 1997. The option to pay bills at the BC Hydro website is coming shortly. U. S. utility companies are reported to be far more advanced in the use of the Internet; according to a study by Deloitte Consulting, U.S. utilities are advancing to the next stage wherein Web intermediaries will be offering 'shop bots' that do comparison shopping on behalf of a customer, including bidding for power on a customer's behalf at energy auctions, reverse auctions, where sellers are bidding for customers' services, and buyers clubs where customers join together to take advantage of volume buying power

  18. On-line monitoring and inservice inspection in codes

    International Nuclear Information System (INIS)

    Bartonicek, J.; Zaiss, W.; Bath, H.R.

    1999-01-01

    The relevant regulatory codes determine the ISI tasks and the time intervals for recurrent components testing for evaluation of operation-induced damaging or ageing in order to ensure component integrity on the basis of the last available quality data. In-service quality monitoring is carried out through on-line monitoring and recurrent testing. The requirements defined by the engineering codes elaborated by various institutions are comparable, with the KTA nuclear engineering and safety codes being the most complete provisions for quality evaluation and assurance after different, defined service periods. German conventional codes for assuring component integrity provide exclusively for recurrent inspection regimes (mainly pressure tests and optical testing). The requirements defined in the KTA codes however always demanded more specific inspections relying on recurrent testing as well as on-line monitoring. Foreign codes for ensuring component integrity concentrate on NDE tasks at regular time intervals, with time intervals scope of testing activities being defined on the basis of the ASME code, section XI. (orig./CB) [de

  19. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  20. Aria Sardinia: the on line community joining tradition and innovatiom

    Directory of Open Access Journals (Sweden)

    Fabrizio Lao

    2005-12-01

    Full Text Available The "ARIA Sardinia" project (Network Actions for Italians Abroad has been especially designed to integrate and give value to the network of relationships between public administrations, local socio-economic stakeholders and Italian communities abroad, this goal to be pursued with the support of new technologies and learning approaches emerging within the context of on line interest communities. The general objective of the project is the development of competencies and knowledge, intended to combine specific technical skills with local "territorial knowledge", in a process where the strengthening and the dissemination of these forms of culture come from the prompt use of innovative tools. The main activities of the project are the actions intended to guide and assist entrepreneurs, associations, development projects' partners or promoters in the path of acquisition and dissemination of the competencies which are necessary to the involvement of Italians abroad into the internationalization process of Sardinian economy. ARIA Sardinia was funded by the Italian Foreign Affairs Ministry and the European Social Fund (FSE, within the framework of the National Operational Program for Technical Assistance and System Action (PON ATAS aimed at specific promotion initiatives and fostering of permanent links between Southern Italy economy and Italians living abroad. Keywords: on line community, networking, Italians abroad, Sardinian economy, Sardinia, culture.

  1. The Automated Threaded Fastening Based on On-line Identification

    Directory of Open Access Journals (Sweden)

    Nicolas Ivan Giannoccaro

    2008-11-01

    Full Text Available The principle of the thread fastenings have been known and used for decades with the purpose of joining one component to another. Threaded fastenings are popular because they permit easy disassembly for maintenance, repair, relocation and recycling. Screw insertions are typically carried out manually. It is a difficult problem to automat. As a result there is very little published research on automating threaded fastenings, and most research on automated assembly focus on the peg-in-hole assembly problem. This paper investigates the problem of automated monitoring of the screw insertion process. The monitoring problem deals with predicting integrity of a threaded insertion, based on the torque vs. insertion depth curve generated during the insertions. The authors have developed an analytical model to predict the torque signature signals during self-tapping screw insertions. However, the model requires parameters on the screw dimensions and plate material properties are difficult to measure. This paper presents a study on on-line identification during screw fastenings. An identification methodology for two unknown parameter estimation during a self-tapping screw insertion process is presented. It is shown that friction and screw properties required by the model can be reliably estimated on-line. Experimental results are presented to validate the identification procedure.

  2. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  3. On-line optimal control improves gas processing

    International Nuclear Information System (INIS)

    Berkowitz, P.N.; Papadopoulos, M.N.

    1992-01-01

    This paper reports that the authors' companies jointly funded the first phase of a gas processing liquids optimization project that has the specific purposes to: Improve the return of processing natural gas liquids, Develop sets of control algorithms, Make available a low-cost solution suitable for small to medium-sized gas processing plants, Test and demonstrate the feasibility of line control. The ARCO Willard CO 2 gas recovery processing plant was chosen as the initial test site to demonstrate the application of multivariable on-line optimal control. One objective of this project is to support an R ampersand D effort to provide a standardized solution to the various types of gas processing plants in the U.S. Processes involved in these gas plants include cryogenic separations, demethanization, lean oil absorption, fractionation and gas treating. Next, the proposed solutions had to be simple yet comprehensive enough to allow an operator to maintain product specifications while operating over a wide range of gas input flow and composition. This had to be a supervisors system that remained on-line more than 95% of the time, and achieved reduced plant operating variability and improved variable cost control. It took more than a year to study various gas processes and to develop a control approach before a real application was finally exercised. An initial process for C 2 and CO 2 recoveries was chosen

  4. Amdel on-line analyser at Rooiberg Tin Limited

    International Nuclear Information System (INIS)

    Owen, T.V.

    1987-01-01

    An Amdel on line analysis system was installed on the 'A' mine tin flotation plant at Rooiberg in April 1984. The motivation for the installation was made on account of the large variations in the feed grade to the plant and the resulting need for rapid operational adjustments to control concentrate grades thereby maximising the financial returns. An 'on-line' analyser system presented itself as a suitable alternative to the existing control method of smaller laboratory x-ray fluorescence analysers. On the system as installed at Rooiberg, two probes were fitted in each analysis zone, viz a density probe using high energy gamma radiation from a Cesium 127 source and a specific element absorption probe using low energy gamma radiation from a Americium 241 source. The signals as received from the probes are fed to a line receiver unit in the control room where a micro computer is doing the processing and prints out the information as required. Several advantages of this type of installation were gained at Rooiberg Tin Limited

  5. Project development and commercialisation of on-line analysis systems

    International Nuclear Information System (INIS)

    Watt, J.S.

    2000-01-01

    A project team first in the Australian Atomic Energy Commission (AAEC) and since 1982 in CSIRO has developed many on-line analysis systems for the mineral and energy industries. The development of these projects, usually lasting 7-10 years, has followed a common pattern of laboratory R and D, field trials, commercialisation and technology transfer. This successful pattern is illustrated using examples of the development of systems for the on-line analysis of mineral slurries, for determination of the ash content of coal on conveyors, and for determination of the flow rates of oil, water and gas in pipelines. The first two systems, licensed to Australian companies, are used world-wide. They are now the market leaders for radioisotope gauges in their application field. The third, the multiphase flow meter, was licensed in 1997 to an international company. This meter has even greater potential than the other two systems for economic benefit from its use and for numbers of installations. (author)

  6. Increased Cortical Thickness in Professional On-Line Gamers

    Science.gov (United States)

    Hyun, Gi Jung; Shin, Yong Wook; Kim, Bung-Nyun; Cheong, Jae Hoon; Jin, Seong Nam

    2013-01-01

    Objective The bulk of recent studies have tested whether video games change the brain in terms of activity and cortical volume. However, such studies are limited by several factors including cross-sectional comparisons, co-morbidity, and short-term follow-up periods. In the present study, we hypothesized that cognitive flexibility and the volume of brain cortex would be correlated with the career length of on-line pro-gamers. Methods High-resolution magnetic resonance scans were acquired in twenty-three pro-gamers recruited from StarCraft pro-game teams. We measured cortical thickness in each individual using FreeSurfer and the cortical thickness was correlated with the career length and the performance of the pro-gamers. Results Career length was positively correlated with cortical thickness in three brain regions: right superior frontal gyrus, right superior parietal gyrus, and right precentral gyrus. Additionally, increased cortical thickness in the prefrontal cortex was correlated with winning rates of the pro-game league. Increased cortical thickness in the prefrontal and parietal cortices was also associated with higher performance of Wisconsin Card Sorting Test. Conclusion Our results suggest that in individuals without pathologic conditions, regular, long-term playing of on-line games is associated with volume changes in the prefrontal and parietal cortices, which are associated with cognitive flexibility. PMID:24474988

  7. An On-Line Method for Thermal Diffusivity Detection of Thin Films Using Infrared Video

    Directory of Open Access Journals (Sweden)

    Dong Huilong

    2016-03-01

    Full Text Available A novel method for thermal diffusivity evolution of thin-film materials with pulsed Gaussian beam and infrared video is reported. Compared with common pulse methods performed in specialized labs, the proposed method implements a rapid on-line measurement without producing the off-centre detection error. Through mathematical deduction of the original heat conduction model, it is discovered that the area s, which is encircled by the maximum temperature curve rTMAX(θ, increases linearly over elapsed time. The thermal diffusivity is acquired from the growth rate of the area s. In this study, the off-centre detection error is avoided by performing the distance regularized level set evolution formulation. The area s was extracted from the binary images of temperature variation rate, without inducing errors from determination of the heat source centre. Thermal diffusivities of three materials, 304 stainless steel, titanium, and zirconium have been measured with the established on-line detection system, and the measurement errors are: −2.26%, −1.07%, and 1.61% respectively.

  8. Calibration of high-dynamic-range, finite-resolution x-ray pulse-height spectrometers for extracting electron energy distribution data from the PFRC-2 device

    Science.gov (United States)

    Swanson, C.; Jandovitz, P.; Cohen, S. A.

    2017-10-01

    Knowledge of the full x-ray energy distribution function (XEDF) emitted from a plasma over a large dynamic range of energies can yield valuable insights about the electron energy distribution function (EEDF) of that plasma and the dynamic processes that create them. X-ray pulse height detectors such as Amptek's X-123 Fast SDD with Silicon Nitride window can detect x-rays in the range of 200eV to 100s of keV. However, extracting EEDF from this measurement requires precise knowledge of the detector's response function. This response function, including the energy scale calibration, the window transmission function, and the resolution function, can be measured directly. We describe measurements of this function from x-rays from a mono-energetic electron beam in a purpose-built gas-target x-ray tube. Large-Z effects such as line radiation, nuclear charge screening, and polarizational Bremsstrahlung are discussed.

  9. BOOK REVIEW: ON-LINE EDUCATION: AN EMANCIPATING VISION

    Directory of Open Access Journals (Sweden)

    Reviewed by Dr. Abdullah KUZU

    2006-04-01

    courses. The courses are presented as educational projects in which several methodological strategies are considered, such as: brainstorming, work groups, group dynamics, questionnaires, and direct interviews in on-line time. While making a presentation of the structure of this type of course, a permanent participation of the people involved in the educational process should be encouraged. This interaction will allow the establishing of a foundation for other types of instruments that enrich the project, meaning that it will suggest a permanent systematization of the performed work, during and afterwards, thus outlining the collective work. During the creation process of WEB courses, it has to be considered that these are "oriented by popular education principles, the rhizome, by participation design, by ultiple subjects and by pedagogical mediations. According to our view, it involves a concrete exercise of the participants, a subject treatment of both the learning and the form. In the same way, it implies a socio-historical situation of the constituents of the project, an organization according to the methodologies that was constructed by them". With regard to the actual use of the proposition, it could be said that because of the moment and the conjuncture we are living in, it demands an educational situation of permanent innovation that provides new meaning with respect to the education of the teacher and, for that, the pedagogical mediation processes and the participation programs of web courses have to be acknowledged as relevant. Here it is also worth noting that this proposal does not only include a epistemological dimension but also presents in an outstanding way the 'how, why and for what' of long distance education by exposing several important points of the LDE–Long Distance Education, utilizing an emancipating vision that joins a series of pertinent ideas to a different model for the development of courses, to their processes, as well as to the more

  10. On-Line Screening, Isolation and Identification of Antioxidant Compounds of Helianthemum ruficomum

    Directory of Open Access Journals (Sweden)

    Yasmine Chemam

    2017-02-01

    Full Text Available Many Helianthemum species (Cistaceae are recognized for their various medicinal virtues. Helianthemum ruficomum is an endemic species to the septentrional Sahara on which no report is available so far. The purpose of this work was to investigate the chemical composition and the radical scavenging capacity of this species and its isolated components. Collected from Mougheul (south-west of Algeria, the aerial parts were macerated with 80% EtOH/H2O, after evaporation, the remaining extract was diluted with H2O and extracted with petroleum ether, chloroform, ethyl acetate and n-butanol. EtOAc and n-BuOH extracts were evaluated for their free radical scavenging capacity by on-line HPLC-ABTS•+ assay. The obtained data which were confirmed by TEAC and ORAC assays, allowed guiding the fractionation of these extracts by CC, TLC and reverse phase HPLC. Among the components, 14 were isolated and identified by spectroscopic analyses: protocatechuic acid (1, trans-tiliroside (2, cis-tiliroside (3, astragalin (4, picein (7, vanillic acid 4-O-β-d-glucopyranoside (8, lavandoside (9, 4-hydroxybenzoic acid 4-O-β-d-glucopyranoside (10, nicotiflorin (11, rutin (12, vicenin-2 (13, narcissin (14 and stigmasterol (5 and β-sitosterol (6 as a mixture (71% and 29%, respectively. Compounds 5, 7, 8, 9, 10 and 14 were new for the genus Helianthemum. The antioxidant power of all the isolated compounds was also evaluated by HPLC-ABTS•+, TEAC and ORAC assays. The results clearly indicated high antioxidant potential of the extracts and tested compounds of this species especially, compounds 1, 4, 8, 9, 10 and 12.

  11. Antimutagenic activity of green tea and black tea extracts studied in a dynamic in vitro gastrointestinal model

    NARCIS (Netherlands)

    Krul, C.A.M.; Luiten-Schuite, A.; Tenfelde, A.; Ommen, B. van; Verhagen, H.; Havenaar, R.

    2001-01-01

    An in vitro gastrointestinal model, which simulates the conditions in the human digestive tract, was used to determine potential antimutagenic activity of extracts of black tea and green tea. In this paper, results are presented on the availability for absorption of potential antimutagenic compounds

  12. Automatic extraction of forward stroke volume using dynamic PET/CT: a dual-tracer and dual-scanner validation in patients with heart valve disease.

    Science.gov (United States)

    Harms, Hendrik Johannes; Tolbod, Lars Poulsen; Hansson, Nils Henrik Stubkjær; Kero, Tanja; Orndahl, Lovisa Holm; Kim, Won Yong; Bjerner, Tomas; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiær, Jørgen; Sörensen, Jens

    2015-12-01

    The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR). FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation.

  13. An on-line monitoring system for a micro electrical discharge machining (micro-EDM) process

    International Nuclear Information System (INIS)

    Liao, Y S; Chang, T Y; Chuang, T J

    2008-01-01

    A pulse-type discriminating system to monitor the process of micro electrical discharge machining (micro-EDM) is developed and implemented. The specific features are extracted and the pulses from a RC-type power source are classified into normal, effective arc, transient short circuit and complex types. An approach to discriminate the pulse type according to three durations measured at three pre-determined voltage levels of a pulse is proposed. The developed system is verified by using simulated signals. Discrimination of the pulse trains in actual machining processes shows that the pulses are mainly the normal type for micro wire-EDM and micro-EDM milling. The pulse-type distribution varies during the micro-EDM drilling process. The percentage of complex-type pulse increases monotonically with the drilling depth. It starts to drop when the gap condition is seriously deteriorated. Accordingly, an on-line monitoring strategy for the micro-EDM drilling process is proposed

  14. Novel Approach for Lithium-Ion Battery On-Line Remaining Useful Life Prediction Based on Permutation Entropy

    Directory of Open Access Journals (Sweden)

    Luping Chen

    2018-04-01

    Full Text Available The degradation of lithium-ion battery often leads to electrical system failure. Battery remaining useful life (RUL prediction can effectively prevent this failure. Battery capacity is usually utilized as health indicator (HI for RUL prediction. However, battery capacity is often estimated on-line and it is difficult to be obtained by monitoring on-line parameters. Therefore, there is a great need to find a simple and on-line prediction method to solve this issue. In this paper, as a novel HI, permutation entropy (PE is extracted from the discharge voltage curve for analyzing battery degradation. Then the similarity between PE and battery capacity are judged by Pearson and Spearman correlation analyses. Experiment results illustrate the effectiveness and excellent similar performance of the novel HI for battery fading indication. Furthermore, we propose a hybrid approach combining Variational mode decomposition (VMD denoising technique, autoregressive integrated moving average (ARIMA, and GM(1,1 models for RUL prediction. Experiment results illustrate the accuracy of the proposed approach for lithium-ion battery on-line RUL prediction.

  15. An integrated on-line irradiation and in situ live cell imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen, E-mail: gen.yang@pku.edu.cn; Wang, Yugang

    2015-09-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO{sub 2}, O{sub 2} concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia.

  16. On-line validation of feedwater flow rate in nuclear power plants using neural networks

    International Nuclear Information System (INIS)

    Khadem, M.; Ipakchi, A.; Alexandro, F.J.; Colley, R.W.

    1994-01-01

    On-line calibration of feedwater flow rate measurement in nuclear power plants provides a continuous realistic value of feedwater flow rate. It also reduces the manpower required for periodic calibration needed due to the fouling and defouling of the venturi meter surface condition. This paper presents a method for on-line validation of feedwater flow rate in nuclear power plants. The method is an improvement of the previously developed method which is based on the use of a set of process variables dynamically related to the feedwater flow rate. The online measurements of this set of variables are used as inputs to a neural network to obtain an estimate of the feedwater flow rate reading. The difference between the on-line feedwater flow rate reading, and the neural network estimate establishes whether there is a need to apply a correction factor to the feedwater flow rate measurement for calculation of the actual reactor power. The method was applied to the feedwater flow meters in the two feedwater flow loops of the TMI-1 nuclear power plant. The venturi meters used for flow measurements are susceptible to frequent fouling that degrades their measurement accuracy. The fouling effects can cause an inaccuracy of up to 3% relative error in feedwater flow rate reading. A neural network, whose inputs were the readings of a set of reference instruments, was designed to predict both feedwater flow rates simultaneously. A multi-layer feedforward neural network employing the backpropagation algorithm was used. A number of neural network training tests were performed to obtain an optimum filtering technique of the input/output data of the neural networks. The result of the selection of the filtering technique was confirmed by numerous Fast Fourier Transform (FFT) tests. Training and testing were done on data from TMI-1 nuclear power plant. The results show that the neural network can predict the correct flow rates with an absolute relative error of less than 2%

  17. An integrated on-line irradiation and in situ live cell imaging system

    International Nuclear Information System (INIS)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen; Wang, Yugang

    2015-01-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO 2 , O 2 concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia

  18. An integrated on-line irradiation and in situ live cell imaging system

    Science.gov (United States)

    Liang, Ying; Fu, Qibin; Wang, Weikang; Liu, Yu; Liu, Feng; Yang, Gen; Wang, Yugang

    2015-09-01

    Ionizing radiation poses a threat to genome integrity by introducing DNA damages, particularly DNA double-strand breaks (DSB) in cells. Understanding how cells react to DSB and maintain genome integrity is of major importance, since increasing evidences indicate the links of DSB with genome instability and cancer predispositions. However, tracking the dynamics of DNA damages and repair response to ionizing radiation in individual cell is difficult. Here we describe the development of an on-line irradiation and in situ live cell imaging system based on isotopic sources at Institute of Heavy Ion Physics, Peking University. The system was designed to irradiate cells and in situ observe the cellular responses to ionizing radiation in real time. On-line irradiation was achieved by mounting a metal framework that hold an isotopic γ source above the cell culture dish for γ irradiation; or by integrating an isotopic α source to an objective lens under the specialized cell culture dish for α irradiation. Live cell imaging was performed on a confocal microscope with an environmental chamber installed on the microscope stage. Culture conditions in the environment chamber such as CO2, O2 concentration as well as temperature are adjustable, which further extends the capacity of the system and allows more flexible experimental design. We demonstrate the use of this system by tracking the DSB foci formation and disappearance in individual cells after exposure to irradiation. On-line irradiation together with in situ live cell imaging in adjustable culture conditions, the system overall provides a powerful tool for investigation of cellular and subcellular response to ionizing radiation under different physiological conditions such as hyperthermia or hypoxia.

  19. Tunable diode laser absorption spectroscopy-based tomography system for on-line monitoring of two-dimensional distributions of temperature and H2O mole fraction

    International Nuclear Information System (INIS)

    Xu, Lijun; Liu, Chang; Jing, Wenyang; Cao, Zhang; Xue, Xin; Lin, Yuzhen

    2016-01-01

    To monitor two-dimensional (2D) distributions of temperature and H 2 O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors’ knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H 2 O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm −1 (1343.3 nm) and 7185.6 cm −1 (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H 2 O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H 2 O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis

  20. On-line determination of moisture in coal and coke

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Sowerby, B.D.

    1987-01-01

    The CSIRO Division of Mineral Engineering is developing various techniques for the on-line determination of moisture in coal and coke, and some instruments are now commercially available. These techniques permit accurate and rapid determination of moisture in materials directly on conveyor belts or in bins. The most promising techniques for direct on-belt measurement of moisture in coal are capacitance and microwave transmission. A non-contacting under-belt capacitance and gamma-ray backscatter technique has determined moisture in coal to better than 0.5 wt% in field tests. CSIRO is developing a fast neutron and gamma-ray transmission technique, which is proving very accurate in laboratory tests. This technique overcomes many of the limitations of thermal neutrons moisture gauges

  1. On-line monitoring system for utility boiler diagnostics

    International Nuclear Information System (INIS)

    Radovanovic, P.M.; Afgan, N.H.; Caralho, M.G.

    1997-01-01

    The paper deals with the new developed modular type Monitoring System for Utility Boiler Diagnostics. Each module is intended to assess the specific process and can be used as a stand alone application. Four modules are developed, namely: LTC - module for the on-line monitoring of parameters related to the life-time consumption of selected boiler components; TRD - module for the tube rupture detection by the position and working fluid Ieakage quantity; FAM - module for the boiler surfaces fouling (slagging) assessment and FLAP - module for visualization of the boiler furnace flame position. All four modules are tested on respective pilot plants built oil the 200 and 300 MWe utility boilers. Monitoring System is commercially available and can be realized in any combination of its modules depending on demands induced by the operational problems of specific boiler. Further development of Monitoring System is performed in accordance with the respective EU project on development of Boiler Expert System. (Author)

  2. On-line Certification for All: The PINVOX Algorithm

    Directory of Open Access Journals (Sweden)

    E Canessa

    2012-09-01

    Full Text Available A protoype algorithm: PINVOX (“Personal Identification Number by Voice" for on-line certification is introduced to guarantee that scholars have followed, i.e., listened and watched, a complete recorded lecture with the option of earning a certificate or diploma of completion after remotely attending courses. It is based on the injection of unique, randomly selected and pre-recorded integer numbers (or single letters or words within the audio trace of a video stream at places where silence is automatically detected. The certificate of completion or “virtual attendance” is generated on-the-fly after the successful identification of the embedded PINVOX code by a video viewer student.

  3. On-line monitoring system for I-131 manufacturing labs

    International Nuclear Information System (INIS)

    Osovizky, A.; Malamud, Y.; Paran, Y.; Tal, N.; Turgeman, S.; Weinstein, M.

    1997-01-01

    An on-line monitoring and safety system has been installed in a lab for manufacturing 1-131 capsules for nuclear medicine use. Production of up to 100mCi batches is performed in shielded glove boxes. The safety system is based on a unique, 'Medi SMARTS' system (Medical Survey Mapping Automatic Radiation Tracing System), that collects continuously the radiation measurements for processing, display, and storage for future retrieval. Radiation is measured by GM tubes, data is transferred to a data processing unit, and then via a RS-485 communication line to a computer. In addition to the operational advantages and radiation levels storage, the system is being evaluated for the purpose of identifying risky stages in the process. (authors)

  4. Issues for Bringing Electron Beam Irradiators On-Line

    International Nuclear Information System (INIS)

    Kaye, R.J.; Turman, B.N.

    1999-01-01

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined

  5. On-line fatigue monitoring system for reactor pressure vessel

    International Nuclear Information System (INIS)

    Tokunaga, K.; Sakai, A.; Aoki, T.; Ranganath, S.; Stevens, G.L.

    1994-01-01

    A workstation-based, on-line fatigue monitoring system for tracking fatigue usage applied to an operating boiling water reactor (BWR), Tsuruga Unit-1, is described. The system uses the influence function approach and determines component stresses using temperature, pressure, and flow rate data that are made available via signal taps from previously existing plant sensors. Using plant unique influence functions developed specifically for the feedwater nozzle location, the system calculates stresses as a function of time and computed fatigue usage. The analysis method used to compute fatigue usage complies with MITI Code Notification No.501. Fatigue usage results for an entire fuel cycle are presented and compared to assumed design basis events to confirm that actual plant thermal duty is significantly less severe than originally estimated in the design basis stress report. As a result, the system provides the technical basis to more accurately evaluate actual reactor conditions as well as the justification for plant life extension. (author)

  6. On-line fatigue monitoring and probabilistic assessment of margins

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, I. [Electricite de France, 93 - Saint-Denis (France). Direction des Etudes et Recherches; Morilhat, P. [Electricite de France, 93 - Saint-Denis (France). Direction des Etudes et Recherches

    1995-01-01

    An on-line computer-aided system has been developed by Electricite de France, the French utility, for fatigue monitoring of critical locations in the nuclear steam supply system. This tool, called a fatigue meter, includes as input data plant parameters and is based on some conservative assumptions at several steps of the damage assessment (thermal boundary conditions, stress computation,..). In this paper we present recent developments performed towards a better assessment of margins involved in the complete analysis. The methodology is illustrated with an example showing the influence of uncertainty in plant parameters on the final stress computed at a pressurized water reactor 900MW unit pressurizer surge line nozzle. A second example is shown to illustrate the possibility of defining some transient archetypes. ((orig.)).

  7. On-line Monitoring of Instrumentation in Research Reactors

    International Nuclear Information System (INIS)

    2017-12-01

    This publication is the result of a benchmarking effort undertaken under the IAEA coordinated research project on improved instrumentation and control (I&C) maintenance techniques for research reactors. It lays the foundation for implementation of on-line monitoring (OLM) techniques and establishment of the validity of those for improved maintenance practices in research reactors for a number of applications such as change to condition based calibration, performance monitoring of process instrumentation systems, detection of process anomalies and to distinguish between process problems/effects and instrumentation/sensor issues. The techniques and guidance embodied in this publication will serve the research reactor community in providing the technical foundation for implementation of OLM techniques. It is intended to be used by Member States to implement I&C maintenance and to improve performance of research reactors.

  8. The Task Manager for the LHCb On-Line Farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2004-01-01

    The Task Manager is a utility to start, stop and list processes on the on-line farm. Each process started by the Task Manager has a string environment variable set, named UTGID (User defined unique Thread Group Identifier) which allows to identify the process. The Task Manager uses the UTGID to list the running processes and to identify the processes to be stopped. It has also the ability to start a process using a particular user name and to set the scheduler type and the priority for the process itself. The Task Manager package includes a Linux DIM server (tmSrv), four Linux command line DIM clients (tmStart, tmLs, tmKill and tmStop) and a JCOP (Joint Control Project) PVSS client.

  9. On-line Corrosion Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2005-01-01

    The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress, ......, precipitation of deposits or crevices. The authors describe methods used for on-line monitoring of corrosion, cover the complications and the main results of a Nordic project.......The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress...

  10. NOASYS, a system for on-line noise analysis

    International Nuclear Information System (INIS)

    Massier, H.

    1978-07-01

    This report describes NOASYS, a versatile NOise Analysis SYStem for digital on-line signal processing. The system based on a minicomputer, was originally developed for the analysis of noise signals from nuclear reactors. NOASYS computes various statistical functions e.g. cross- und auto-correlation functions and power spectral densities resp., which may be used for reactor diagnosis and malfunction detection. The system processes up to 16 analog signals with a maximum sampling frequency of 100 kcps (1 channel). The processing of the sampled data is done by a number of software tasks, which may be called from a teletype or linked together for specific measuring programs. The standard configuration contains the often used processing routines e.g. Fast Fourier Transform, complex multiplication, summation etc. In addition NOASYS may be extended by users own tasks (in Assembler or Fortran) to fit for specific applications. (orig.) 891 HP [de

  11. On-line efficiency optimization of a synchronous reluctance motor

    Energy Technology Data Exchange (ETDEWEB)

    Lubin, Thierry; Razik, Hubert; Rezzoug, Abderrezak [Groupe de Recherche en Electrotechnique et Electronique de Nancy, GREEN, CNRS-UMR 7037, Universite Henri Poincare, BP 239, 54506 Vandoeuvre-les-Nancy Cedex (France)

    2007-04-15

    This paper deals with an on-line optimum-efficiency control of a synchronous reluctance motor drive. The input power minimization control is implemented with a search controller using Fibonacci search algorithm. It searches the optimal reference value of the d-axis stator current for which the input power is minimum. The input power is calculated from the measured dc-bus current and dc-bus voltage of the inverter. A rotor-oriented vector control of the synchronous reluctance machine with the optimization efficiency controller is achieved with a DSP board (TMS302C31). Experimental results are presented to validate the proposed control methods. It is shown that stability problems can appear during the search process. (author)

  12. Development of on-line monitoring system using smart material

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Kyung; Lee, Sang Pill; Park, Yi Hyun [Dongeui Univ., Busan (Korea, Republic of); Park, Young Chul [Donga Univ., Busan (Korea, Republic of)

    2003-07-01

    A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA.

  13. Development of on-line monitoring system using smart material

    International Nuclear Information System (INIS)

    Lee, Jin Kyung; Lee, Sang Pill; Park, Yi Hyun; Park, Young Chul

    2003-01-01

    A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA

  14. Issues for Bringing Electron Beam Irradiators On-Line

    Energy Technology Data Exchange (ETDEWEB)

    Kaye, R.J.; Turman, B.N.

    1999-04-20

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined.

  15. Escapist Motives for Playing On-Line Games

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    2012-01-01

    Social games have become popular along with the tremendous growth of social networking sites, esp. Facebook. There is a gap in literature on what motivates people to play Facebook games. This paper studies social games usage behavior of students. We focus on escapist reasons, based on Warmelink...... of escapist motives for playing Facebook and other on-line games, we investigate how they are linked to demographic data such as: age, gender, place of origin, along with other social interactions patterns and social network usage behavior, current gaming status and an estimate of gaming time. According...... to our study, only 10% of respondents, who have started to play Facebook games, continued to play them. The most important motives for playing games is mundane breaking, the second reason is pleasure seeking, the third is stress relieving, and the least important is imagination conjuring....

  16. Configuration Database for BaBar On-line

    International Nuclear Information System (INIS)

    Salnikov, Andrei

    2003-01-01

    The configuration database is one of the vital systems in the BaBar on-line system. It provides services for the different parts of the data acquisition system and control system, which require run-time parameters. The original design and implementation of the configuration database played a significant role in the successful BaBar operations since the beginning of experiment. Recent additions to the design of the configuration database provide better means for the management of data and add new tools to simplify main configuration tasks. We describe the design of the configuration database, its implementation with the Objectivity/DB object-oriented database, and our experience collected during the years of operation

  17. 3rd Computer Science On-line Conference

    CERN Document Server

    Senkerik, Roman; Oplatkova, Zuzana; Silhavy, Petr; Prokopova, Zdenka

    2014-01-01

    This book is based on the research papers presented in the 3rd Computer Science On-line Conference 2014 (CSOC 2014).   The conference is intended to provide an international forum for discussions on the latest high-quality research results in all areas related to Computer Science. The topics addressed are the theoretical aspects and applications of Artificial Intelligences, Computer Science, Informatics and Software Engineering.   The authors provide new approaches and methods to real-world problems, and in particular, exploratory research that describes novel approaches in their field. Particular emphasis is laid on modern trends in selected fields of interest. New algorithms or methods in a variety of fields are also presented.   This book is divided into three sections and covers topics including Artificial Intelligence, Computer Science and Software Engineering. Each section consists of new theoretical contributions and applications which can be used for the further development of knowledge of everybod...

  18. On-line Ciphers and the Hash-CBC Constructions

    DEFF Research Database (Denmark)

    Bellare, M.; Boldyreva, A.; Knudsen, Lars Ramkilde

    2012-01-01

    We initiate a study of on-line ciphers. These are ciphers that can take input plaintexts of large and varying lengths and will output the i th block of the ciphertext after having processed only the first i blocks of the plaintext. Such ciphers permit length-preserving encryption of a data stream...... with only a single pass through the data. We provide security definitions for this primitive and study its basic properties. We then provide attacks on some possible candidates, including CBC with fixed IV. We then provide two constructions, HCBC1 and HCBC2, based on a given block cipher E and a family...... of computationally AXU functions. HCBC1 is proven secure against chosen-plaintext attacks assuming that E is a PRP secure against chosen-plaintext attacks, while HCBC2 is proven secure against chosen-ciphertext attacks assuming that E is a PRP secure against chosen-ciphertext attacks....

  19. On-line defected fuel monitoring using GFP data

    International Nuclear Information System (INIS)

    Livingstone, S.; Lewis, B.J.

    2008-01-01

    This paper describes the initial development of an on-line defected fuel diagnostic tool. The tool is based on coolant activity, and uses a quantitative and qualitative approach from existing mechanistic fission product release models, and also empirical rules based on commercial and experimental experience. The model departs from the usual methodology of analyzing steady-state fission product coolant activities, and instead uses steady-state fission product release rates calculated from the transient coolant activity data. An example of real-time defected fuel analysis work is presented using a prototype of this tool with station data. The model is in an early developmental stage, and this paper demonstrates the promising potential of this technique. (author)

  20. An on-line advanced plant simulator (OLAPS)

    International Nuclear Information System (INIS)

    Samuels, J.W.

    1989-01-01

    A PC based on-line advanced plant simulator (OLAPS) for high quality simulations of Portland General Electric's Trojan Nuclear Facility is presented. OLAPS is designed to simulate the thermal-hydraulics of the primary system including core, steam generators, pumps, piping and pressurizer. The simulations are based on a five equation model that has two mass equations, two energy equations, two energy equations, and one momentum equation with a drift flux model to provide closure. A regionwise point reactor kinetics model is used to model the neutron kinetics in the core. The conservation equations, constitutive models and the numerical methods used to solve them are described. OLAPS results are compared with data from chapter 15 of the Trojan Nuclear Facility's final safety analysis report