WorldWideScience

Sample records for on-line cyclotron beam

  1. On-line measurements of proton beam current from a PET cyclotron using a thin aluminum foil

    Science.gov (United States)

    Ghithan, S.; do Carmo, S. J. C.; Ferreira Marques, R.; Fraga, F. A. F.; Simões, H.; Alves, F.; Crespo, P.

    2013-07-01

    The number of cyclotrons capable of accelerating protons to about 20 MeV is increasing throughout the world. Originally aiming at the production of positron emission tomography (PET) radionuclides, some of these facilities are equipped with several beam lines suitable for scientific research. Radiobiology, radiophysiology, and other dosimetric studies can be performed using these beam lines. In this work, we measured the Bragg peak of the protons from a PET cyclotron using a stacked target consisting of several aluminum foils interleaved with polyethylene sheets, readout by in-house made transimpedance electronics. The measured Bragg peak is consistent with simulations performed using the SRIM/TRIM simulation toolkit. Furthermore, we report on experimental results aiming at measuring proton beam currents down to 10 pA using a thin aluminum foil (20-μm-thick). The aluminum was chosen for this task because it is radiation hard, it has low density and low radiation activity, and finally because it is easily available at negligible cost. This method allows for calculating the dose delivered to a target during an irradiation with high efficiency, and with minimal proton energy loss and scattering.

  2. Progress of General Test Stand for Intensive Beam Cyclotron

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>The general test stand for intensive beam cyclotron is one of the preliminary tasks of BRIF project at CIAE. The test stand, which actually is a small compact cyclotron with designed energy of 10 MeV,

  3. Beam stripping extraction from the VINCY cyclotron

    Directory of Open Access Journals (Sweden)

    Ristić-Đurović Jasna L.

    2006-01-01

    Full Text Available The extraction system of a cyclotron guides an ion beam from a spiral acceleration orbit, through an extraction trajectory, into a high energy transport line. The two methods commonly used to direct an ion into the extraction path are deflection, by the electric field of an electrostatic deflector, and ion stripping, by a thin carbon foil. Compared to the electrostatic deflector system, the stripping extraction provides a fast and easy change of the extracted ion energy and is easier to manufacture operate, and maintain. However, the extraction trajectory and dynamics of an ion beam after stripping are highly dependant on the ion energy and specific charge. Thus, when a multipurpose machine such as the VINCY Cyclotron is concerned, it is far from easy to deliver a variety of ion beams into the same high energy transport line and at the same time preserve a reasonable compactness of the extraction system. The front side stripping extraction system of the VINCY Cyclotron provides high (~70 MeV and mid (~30 MeV energy protons, as well as a number of heavy ions in broad energy ranges. The back side stripping extraction system extracts low energy protons (~18 MeV and enables their simultaneous use with high energy protons at the front side of the machine.

  4. Development of beam instruments at JAERI cyclotron facility

    Energy Technology Data Exchange (ETDEWEB)

    Okumura, Susumu; Fukuda, Mitsuhiro; Ishibori, Ikuo; Agematsu, Takashi; Yokota, Watalu; Nara, Takayuki; Nakamura, Yoshiteru; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A beam phase monitor and two kinds of fluence distribution monitors have been developed for measuring characteristics of cyclotron beams. The beam phase monitor provides a beam phase signal for tuning a beam chopping system and a beam phase selection system. A two-dimensional fluence distribution on a large area is measured with fluence distribution monitors. (author)

  5. Beam Phase Measurements in the AGOR Cyclotron

    CERN Document Server

    Brandenburg, S; Van Asselt, W K

    2003-01-01

    Beamphase measurement to optimize the isochronism is an essential part of the diagnostics in multi-particle, multi-energy cyclotrons. In the AGOR cyclotron an array of 13 nondestructive beamphase pick-ups is installed. To reduce the large disturbances from the RF-system the measurements are traditionally performed at the 2nd harmonic of the RF-frequency. To further improve the sensitivity intensity modulation of the beam has been introduced. This creates side-bands in the Fourier spectrum, that are completely free of interference from the RF-system. These side-bands contain information on both the beamphase with respect to the accelerating voltage and the number of revolutions up to the radius of the measurement. A specific case is intensity modulation at the orbital frequency, where the side-bands contain only information on the beamphase. Measurements with the different methods will be presented, demonstrating that the intensity modulation strongly improves the sensitivity of the measurement. Useful beampha...

  6. Ion-Beam-Excited Electrostatic Ion Cyclotron Waves

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field.......Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field....

  7. Unstable Electrostatic Ion Cyclotron Waves Exited by an Ion Beam

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Electrostatic ion cyclotron waves were observed in a quiescent cesium plasma into which a low‐energy beam of sodium ions was injected. The instability appeared when the beam velocity was above 12 times the ion thermal velocity. The waves propagated along the magnetic field with a velocity somewhat...

  8. Heavy ion beam transmission in the AGOR cyclotron

    NARCIS (Netherlands)

    Sen, Ayanangsha

    2013-01-01

    In the framework of the TRImP program initiated at the KVI in 2002, the AGOR cyclotron was used to accelerate low energy heavy ion beams up to a beam intensity (>=10^12 particles per second). Typical beam ions are: 206Pb accelerated to 8 MeV/amu and 20Ne accelerated to 25 MeV/amu. In the course of b

  9. Influence of injection beam emittance on beam transmission efficiency in a cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kurashima, Satoshi, E-mail: kurashima.satoshi@jaea.go.jp; Kashiwagi, Hirotsugu; Miyawaki, Nobumasa; Yoshida, Ken-Ichi; Okumura, Susumu [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-02-15

    The JAEA AVF cyclotron accelerates various kinds of high-energy ion beams for research in biotechnology and materials science. Beam intensities of an ion species of the order of 10{sup −9}–10{sup −6} ampere are often required for various experiments performed sequentially over a day. To provide ion beams with sufficient intensity and stability, an operator has to retune an ion source in a short time. However, the beam intensity downstream of the cyclotron rarely increases in proportion to the intensity at the ion source. To understand the cause of this beam behavior, transmission efficiencies of a {sup 12}C{sup 5+} beam from an electron cyclotron resonance ion source to the cyclotron were measured for various conditions of the ion source. Moreover, a feasible region for acceleration in the emittance of the injection beam was clarified using a transverse-acceptance measuring system. We confirmed that the beam emittance and profile were changed depending on the condition of the ion source and that matching between the beam emittance and the acceptance of the cyclotron was degraded. However, after fine-tuning to improve the matching, beam intensity downstream of the cyclotron increased.

  10. Optimal Design of Proposed 800 MeV Proton Cyclotron Beam Dynamics

    Institute of Scientific and Technical Information of China (English)

    YANG; Jian-jun; LI; Ming; ZHANG; Tian-jue; SONG; Guo-fang; AN; Shi-zhong

    2015-01-01

    The high intensity beam dynamic simulation shows that the theoretic beam current limit of the original design version of the 800 MeV proton cyclotron CYCIEA-800is 1mA.In order to further improve the current limit and reduce beam losses in the cyclotron,the layout of the cyclotron

  11. Beam phase measurement in the AGOR-cyclotron

    NARCIS (Netherlands)

    Brandenburg, S; Roobol, LP; Schreuder, HW; de Vries, L; Laune, B; Baron, E.; Lieuvin, M.

    1999-01-01

    The AGOR cyclotron is equipped with thirteen phase probes for optimization of the isochronism The beam phase is measured at the 2(nd) harmonic of the RF frequency, in order to be able to suppress the large RF interference from the nearby resonators. At low RF frequencies a phase accuracy of 1 deg. i

  12. Ion-Beam-Excited Electrostatic Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  13. Ion-Beam-Excited, Electrostatic, Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  14. Effects of electron-cyclotron instabilities on gyrotron beam quality

    Energy Technology Data Exchange (ETDEWEB)

    Jost, G.; Tran, T.M.; Appert, K. [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP); Wuethrich, S. [CRAY Research, PATP/PSE, EPFL, Lausanne (Switzerland)

    1996-02-01

    A two-dimensional PIC code aimed at the investigation of electron-cyclotron beam instabilities in gyrotrons and their effects on the beam quality is presented. The code is based on recently developed techniques for handling charge conservation and open boundaries. It has been implemented on the massively parallel computer CRAY T3D. First results show an electromagnetic backward instability periodically growing and decaying to energy levels close to those obtained from the electrostatic Bernstein wave instability. On the average, the resulting beam degradation is 3 to 4 times larger than that predicted by electrostatic models. (author) 8 figs., 14 refs.

  15. On-line laser spectroscopy with thermal atomic beams

    CERN Document Server

    Thibault, C; De Saint-Simon, M; Duong, H T; Guimbal, P; Huber, G; Jacquinot, P; Juncar, P; Klapisch, Robert; Liberman, S; Pesnelle, A; Pillet, P; Pinard, J; Serre, J M; Touchard, F; Vialle, J L

    1981-01-01

    On-line high resolution laser spectroscopy experiments have been performed in which the light from a CW tunable dye laser interacts at right angles with a thermal atomic beam. /sup 76-98/Rb, /sup 118-145 /Cs and /sup 208-213/Fr have been studied using the ionic beam delivered by the ISOLDE on-line mass separator at CERN while /sup 30-31/Na and /sup 38-47/K have been studied by setting the apparatus directly on-line with the PS 20 GeV proton beam. The principle of the method is briefly explained and some results concerning nuclear structure are given. The hyperfine structure, spins and isotope shifts of the alkali isotopes and isomers are measured. (8 refs).

  16. Heavy ion cocktail beams at the 88 inch Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Daniela; McMahan, Margaret A.; Argento, David; Gimpel, Thomas; Guy, Aran; Morel, James; Siero, Christine; Thatcher, Ray; Lyneis, Claude M.

    2002-09-03

    Cyclotrons in combination with ECR ion sources provide the ability to accelerate ''cocktails'' of ions. A cocktail is a mixture of ions of near-identical mass-to-charge (m/q) ratio. The different ions cannot be separated by the injector mass-analyzing magnet and are tuned out of the ion source together. The cyclotron then is utilized as a mass analyzer by shifting the accelerating frequency. This concept was developed soon after the first ECR ion source became operational at the 88-Inch Cyclotron and has since become a powerful tool in the field of heavy ion radiation effects testing. Several different ''cocktails'' at various energies are available at the 88-Inch cyclotron for radiation effect testing, covering a broad range of linear energy transfer and penetration depth. Two standard heavy ion cocktails at 4.5 MeV/nucleon and 10 MeV/nucleon have been developed over the years containing ions from boron to bismuth. Recently, following requests for higher penetration depths, a 15MeV/nucleon heavy ion cocktail has been developed. Up to nine different metal and gaseous ion beams at low to very high charge states are tuned out of the ion source simultaneously and injected together into the cyclotron. It is therefore crucial to balance the ion source very carefully to provide sufficient intensities throughout the cocktail. The paper describes the set-up and tuning of the ion source for the various heavy ion cocktails.

  17. Superconducting Ring Cyclotron for Riken RI Beam Factory in Japan

    Science.gov (United States)

    Okuno, H.; Dantsuka, T.; Yamada, K.; Kase, M.; Maie, T.; Kamigaito, O.

    2010-04-01

    Since 1997, RIKEN Nishina Center has been constructing the Radioactive Isotope Beam Factory (RIBF) and succeeded in beam commissioning of its accelerator complex at the end of 2006. The world's first superconducting ring cyclotron (SRC) is the final booster in the RIBF accelerator complex which is able to accelerate all-element heavy ions to a speed of about 70% of the velocity of light. The ring cyclotron consists of 6 major superconducting sector magnets with a maximum field of 3.8 T. The total stored energy is 235 MJ, and its overall sizes are 19 m diameter, 8 m height and 8,300 tons. The magnet system assembly was completed in August 2005, and successfully reached the maximum field in November 2005. The first beam was extracted at the end of 2006 and the first uranium beam was extracted in March 2007. However operation of the helium refrigerator was not satisfactory although the commissioning of SRC was successful. Operation was stopped every two month due to degradation of its cooling power. In February 2008 the reason of the degradation was revealed to be oil contamination. Operation of the cryogenic system was restarted from August 2008 after hard task to clean up the helium refrigerator and to add oil separators to the compressor. After restoration long-term steady operation to keep the magnet superconducting continued for about 8 months with no sign of degradation of cooling capacity.

  18. Prospects for advanced electron cyclotron resonance and electron beam ion source charge breeding methods for EURISOL

    Energy Technology Data Exchange (ETDEWEB)

    Delahaye, P.; Jardin, P.; Maunoury, L.; Traykov, E.; Varenne, F. [GANIL, CEA/DSM-CNRS/IN2P3, Bd. Becquerel, BP 55027, 14076 Caen Cedex 05 (France); Galata, A.; Porcellato, A. M.; Prete, G. F. [INFN-Laboratori Nazionali di Legnaro, Viale dell' Universita 2, 35020 Legnaro, Padova (Italy); Angot, J.; Lamy, T.; Sortais, P.; Thuillier, T. [LPSC Grenoble, 53, rue des Martyrs, 38026 Grenoble Cedex (France); Ban, G. [LPC Caen, 6 bd Marechal Juin, 14050 Caen Cedex (France); Celona, L.; Lunney, D. [INFN-Laboratori Nazionali del Sud, via S.Sofia 62, 95125 Catania (Italy); Choinski, J.; Gmaj, P.; Jakubowski, A.; Steckiewicz, O. [Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5a, 02 093 Warsaw (Poland); Kalvas, T. [Department of Physics, University of Jyvaeskylae, PB 35 (YFL) 40351 Jyvaeskylae (Finland); and others

    2012-02-15

    As the most ambitious concept of isotope separation on line (ISOL) facility, EURISOL aims at producing unprecedented intensities of post-accelerated radioactive isotopes. Charge breeding, which transforms the charge state of radioactive beams from 1+ to an n+ charge state prior to post-acceleration, is a key technology which has to overcome the following challenges: high charge states for high energies, efficiency, rapidity and purity. On the roadmap to EURISOL, a dedicated R and D is being undertaken to push forward the frontiers of the present state-of-the-art techniques which use either electron cyclotron resonance or electron beam ion sources. We describe here the guidelines of this R and D.

  19. R&D of the Fluoroscopes of 100 MeV Cyclotron Beam Lines

    Institute of Scientific and Technical Information of China (English)

    YIN; Meng; GUAN; Feng-ping; XIE; Huai-dong; ZHENG; Xia; XING; Jian-sheng; LV; Yin-long

    2013-01-01

    Beijing Radioactive Ion-beam Facility(BRIF)consists of a 100 MeV H-cyclotron CYCIAE-100and nine beam lines.All the beam lines provide the channels of the proton beam or the neutron beam to the terminal of physics experiment.There are many beam diagnosis monitors distributing along the beam lines,including,Faraday cups,beam position monitors,fluoroscopes,collimators,emittance measurement

  20. Electron Cyclotron Maser Emissions from Evolving Fast Electron Beams

    CERN Document Server

    Tang, J F; Chen, L; Zhao, G Q; Tan, C M

    2016-01-01

    Fast electron beams (FEBs) are common products of solar active phenomena. Solar radio bursts are an important diagnostic tool in the understanding of FEBs as well as the solar plasma environment in which they are propagating along solar magnetic fields. In particular, the evolutions of the energy spectrum and velocity distribution of FEBs due to the interaction with the ambient plasma and field when propagating can significantly influence the efficiency and property of their emissions. In this paper, we discuss some possible evolutions of the energy spectrum and velocity distribution of FEBs due to the energy loss processes and the pitch-angle effect caused by the magnetic field inhomogeneity, and analyze the effects of these evolutions on electron cyclotron maser (ECM) emission, which is one of the most important mechanisms of producing solar radio bursts by FEBs. The results show that the growth rates all decrease with the energy loss factor $Q$, but increase with the magnetic mirror ratio $\\sigma$ as well ...

  1. Applied research with cyclotron beams at FLNR JINR

    Energy Technology Data Exchange (ETDEWEB)

    Oganessian, Yu.Ts.; Apel, P.Yu.; Didyk, A.Yu.; Dmitriev, S.N.; Gulbekian, G.G. [Joint Inst. for Nuclear Research, Dubna, Moscow (Russian Federation). Flerov Lab. of Nuclear Reactions

    1997-03-01

    The Center of Applied Physics at the Flerov Laboratory carries out an R and D program comprising development of track membrane technology, materials research with heavy ion beams and production of radioisotopes. Experiments are performed on three cyclotrons: U-400, U-200 and IC-100 providing a wide variety of ion beams with the energies of 1 to 10 MeV/u. The activity on track membranes (TMs) includes studies of track formation in polymers and latent track structure, track sensitization and etching, methods of membrane testing, development of track membranes on the basis of new materials, surface modification of TMs, design and construction of facilities for track membrane production. Recent experiments on heavy ion-induced radiation damage in non-polymeric substances have been devoted to defect creation in semiconductor and dielectric single crystals. TEM, SEM, STM and `in situ` luminescent spectroscopy are used to investigate heavy ion effects. Methods for producing several isotopes of high radiochemical and isotopic purity for medical, biomedical and environmental protection applications have been developed. (author)

  2. Design of a superconducting beam transport channel and beam dynamics for a strong-focusing cyclotron

    Science.gov (United States)

    Badgley, Karie Elizabeth

    There is an increasing interest in high power proton accelerators for use as neutron and muon sources, accelerator driven systems (ADS) for nuclear waste transmutation, high energy physics, medical physics, nuclear physics, and medical isotope production. Accelerating high current beams has a number of challenges; including avoiding harmful resonance crossing, space charge effects and, specific to cyclotrons, sufficient turn separation at injection and extraction. The Accelerator Research Laboratory at Texas A&M University is developing a high-power strong-focusing cyclotron with two main technologies to overcome these challenges. The first is a superconducting RF cavity to provide the energy gain required for fully separated turns. The second is the use of superconducting beam transport channels within the sectors of the cyclotron to provide strong-focusing with alternating focusing and defocusing quadrupoles. A method has been developed to find the equilibrium spiral orbit through the cyclotron which maintains isochronicity. The isochronous spiral orbit was then used to perform full linear optics calculations. The strengths of the quadrupoles were adjusted to hold the horizontal and vertical betatron tunes constant per turn to avoid resonance crossing. Particle tracking was performed with a modified MAD-X-PTC code and Synergia to provide a framework for future space charge studies. Magnetic modeling was performed on a 2D cross section of the beam transport channel. The wire locations were adjusted to reduce the higher order multipoles and a good field region was obtained at 70% of the beam pipe aperture with multipoles less than 10-4 . The 2D model was also used to determine the required current density needed to produce the quadrupole gradients. MgB2 superconducting wire was chosen as it meets all the field and current requirements and can operate at a reduced cryogenic cost. A winding mandrel was also designed and fabricated which minimized the bend radius for

  3. The beam commissioning of BRIF and future cyclotron development at CIAE

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tianjue, E-mail: tjzhang@ciae.ac.cn; Yang, Jianjun, E-mail: yangjianjun2000@tsinghua.org.cn

    2016-06-01

    As an upgrade project of the existing HI-13 tandem accelerator facility, the Beijing Radioactive Ion-beam Facility (BRIF) is being constructed in China Institute of Atomic Energy (CIAE). This project consists of an 100 MeV proton compact cyclotron, a two-stage ISOL system, a superconducting linac booster and various experimental terminals. The beam commissioning of the cyclotron was launched by the end of 2013 and on July 4, 2014 the first 100 MeV proton beam was received on a temporary target which was positioned at the outlet of the cyclotron. The beam current was stably maintained at above 25 μA for about 9 h on July 25, 2014 and the cyclotron is now ready for providing CW proton beam on target-source for RIB production. The beam current is expected to be increased to 200–500 μA in the coming years. The installation of the ISOL system is finished and the stable ion beam test shows it can reach a mass resolution better than 10,000. It is expected to generate dozens of RIB by 100 MeV proton beam. In addition, this paper also introduces the recent progress of the pre-study of an 800 MeV, 3–4 MW separate-sector proton cyclotron, which is aimed to provide high power proton beam for various applications, such as neutron and neutrino physics, proton radiography and nuclear data measurement and ADS system.

  4. The beam commissioning of BRIF and future cyclotron development at CIAE

    Science.gov (United States)

    Zhang, Tianjue; Yang, Jianjun

    2016-06-01

    As an upgrade project of the existing HI-13 tandem accelerator facility, the Beijing Radioactive Ion-beam Facility (BRIF) is being constructed in China Institute of Atomic Energy (CIAE). This project consists of an 100 MeV proton compact cyclotron, a two-stage ISOL system, a superconducting linac booster and various experimental terminals. The beam commissioning of the cyclotron was launched by the end of 2013 and on July 4, 2014 the first 100 MeV proton beam was received on a temporary target which was positioned at the outlet of the cyclotron. The beam current was stably maintained at above 25 μA for about 9 h on July 25, 2014 and the cyclotron is now ready for providing CW proton beam on target-source for RIB production. The beam current is expected to be increased to 200-500 μA in the coming years. The installation of the ISOL system is finished and the stable ion beam test shows it can reach a mass resolution better than 10,000. It is expected to generate dozens of RIB by 100 MeV proton beam. In addition, this paper also introduces the recent progress of the pre-study of an 800 MeV, 3-4 MW separate-sector proton cyclotron, which is aimed to provide high power proton beam for various applications, such as neutron and neutrino physics, proton radiography and nuclear data measurement and ADS system.

  5. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Science.gov (United States)

    Zhang, Xu; Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming; Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN-LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  6. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xu, E-mail: emmazhang103@gmail.com [China Institute of Atomic Energy (China); Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming [China Institute of Atomic Energy (China); Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir [BEST Cyclotron Inc (Canada)

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN–LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  7. Ion beam driven resonant ion-cyclotron instability in a magnetized dusty plasma

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, Ved; Vijayshri [School of Sciences, Indira Gandhi National Open University, Maidan Garhi, New Delhi 110 068 (India); Sharma, Suresh C. [Department of Applied Physics, Delhi Technological University, Shahbad Daulatpur, Bawana Road, Delhi 110 042 (India); Gupta, Ruby [Department of Physics, Swami Shraddhanand College, University of Delhi, Alipur, Delhi 110 036 (India)

    2014-03-15

    Electrostatic ion cyclotron waves are excited by axial ion beam in a dusty plasma via Cerenkov and slow cyclotron interaction. The dispersion relation of the instability is derived in the presence of positively/negatively charged dust grains. The minimum beam velocity needed for the excitation is estimated for different values of relative density of negatively charged dust grains. It is shown that the minimum beam velocity needed for excitation increases as the charge density carried by dust increases. Temperature of electrons and ions, charge and mass of dust grains, external static magnetic field and finite boundary of dusty plasma significantly modify the dispersion properties of these waves and play a crucial role in the growth of resonant ion cyclotron instability. The ion cyclotron modes with phase velocity comparable to the beam velocity possess a large growth rate. The maximum value of growth rate increases with the beam density and scales as the one-third power of the beam density in Cerenkov interaction and is proportional to the square root of beam density in slow cyclotron interaction.

  8. The ISOLDE on-line isotope separator at the 600 MeV Synchro-Cyclotron

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Is at present being thoroughly modified and improved, in order to allow for the increased proton beam intensities, resulting from the SC improvement programme. This photograph, taken before the dismantinling of the facility in June 1973, shows the separator analysing magnet (centre background), the collector chamber of the mass-separated ion.

  9. High performance computation on beam dynamics problems in high intensity compact cyclotrons

    Institute of Scientific and Technical Information of China (English)

    ADELMANN; Andreas

    2011-01-01

    This paper presents the research progress in the beam dynamics problems for future high intensity compact cyclotrons by utilizing the state-of-the-art high performance computation technology. A "Start-to-Stop" model, which includes both the interaction of the internal particles of a single bunch and the mutual interaction of neighboring multiple bunches in the radial direction, is established for compact cyclotrons with multi-turn extraction. This model is then implemented in OPAL-CYCL, which is a 3D object-oriented parallel code for large scale particle simulations in cyclotrons. In addition, to meet the running requirement of parallel computation, we have constructed a small scale HPC cluster system and tested its performance. Finally, the high intensity beam dynamics problems in the 100 MeV compact cyclotron, which is being constructed at CIAE, are studied using this code and some conclusions are drawn.

  10. Intelligent Low-level RF System by Non-destructive Beam Monitoring Device for Cyclotrons

    CERN Document Server

    Malafeh, M S Sharifi Asadi; Afarideh, H; Chai, J S

    2015-01-01

    The project of a10MeV PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of cyclotron accelerator is designed to stabilize acceleration voltage and control the resonance frequency of the cavity. In this work Intelligent Low Level Radio Frequency Circuit or ILLRF suitable for Most of the AVF cyclotron accelerators was designed by the beam monitoring device and narrow band tunable band-pass filter. In this design, for the RF phase detection does not need to signal processing by microcontroller

  11. Neutron Beams from Deuteron Breakup at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    McMahan, M.A.; Ahle, L.; Bleuel, D.L.; Bernstein, L.; Braquest, B.R.; Cerny, J.; Heilbronn, L.H.; Jewett, C.C.; Thompson, I.; Wilson, B.

    2007-07-31

    Accelerator-based neutron sources offer many advantages, in particular tunability of the neutron beam in energy and width to match the needs of the application. Using a recently constructed neutron beam line at the 88-Inch Cyclotron at LBNL, tunable high-intensity sources of quasi-monoenergetic and broad spectrum neutrons from deuteron breakup are under development for a variety of applications.

  12. Modelling third harmonic ion cyclotron acceleration of deuterium beams for JET fusion product studies experiments

    DEFF Research Database (Denmark)

    Schneider, M.; Johnson, T.; Dumont, R.

    2016-01-01

    Recent JET experiments have been dedicated to the studies of fusion reactions between deuterium (D) and Helium-3 (3He) ions using neutral beam injection (NBI) in synergy with third harmonic ion cyclotron radio-frequency heating (ICRH) of the beam. This scenario generates a fast ion deuterium tail...

  13. The effects of beam line pressure on the beam quality of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Toivanen, V., E-mail: ville.toivanen@jyu.f [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, P.O. Box 35 (YFL), 40500 Jyvaeskylae (Finland); Steczkiewicz, O.; Tarvainen, O.; Ropponen, T.; Arje, J.; Koivisto, H. [University of Jyvaeskylae, Department of Physics, Accelerator Laboratory, P.O. Box 35 (YFL), 40500 Jyvaeskylae (Finland)

    2010-05-01

    The results of a series of measurements studying the possibility to use neutral gas feeding into the beam line as a way to improve the quality of the heavy ion beams produced with an electron cyclotron resonance ion source (ECRIS) are presented. Significant reduction of the beam spot size and emittance can be achieved with this method. The observed effects are presumably due to increased space charge compensation degree of the ion beam in the beam line section between the ion source and the analyzing magnet. This is the region where the neutral gas was injected. It is shown that the effects are independent of the ion source tuning. Transmission measurements through the beam line and K-130 cyclotron have been carried out to study the effects of improved ion beam quality to the transmission efficiency.

  14. On-line desalting of crude oil in the source region of a Fourier transform ion cyclotron resonance mass spectrometer.

    Science.gov (United States)

    Chanthamontri, C Ken; Stopford, Andrew P; Snowdon, Ryan W; Oldenburg, Thomas B P; Larter, Stephen R

    2014-08-01

    The presence of dissolved metal ions in waters associated with crude oils has many negative implications for the transport, processing, and refining of petroleum. In addition, mass spectrometric analysis of sodium containing crude oil samples suffers from ionization suppression, unwanted adduct formation, and an increase in the complexity of data analysis. Here, we describe a method for the reduction/elimination of these adverse effects by modification of the source region gas-inlet system of a 12 T Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. Several acids were examined as part of this study, with the most suitable for on-line desalting found to have both high vapor pressure and low pK(a); 12.1 M HCl showed the strongest desalting effect for crude oil samples with a sodium removal index (SRI) of 88%-100% ± 7% for the NaOS compound class. In comparison, a SRI of only 38% ± 9% was observed for a H₂O/toluene solution-phase extraction of oil 1. These results clearly demonstrate the increased efficacy of pseudo-vapor phase desalting with the additional advantages that initial sample solution conditions are preserved and no sample preparation is required prior to analysis.

  15. Concept of Powerful Multistage Coaxial Cyclotron for Pulsed and Continuous Beam Production

    CERN Document Server

    Tumanyan, A R; Guiragossian, Z G T; Akopov, N Z

    1999-01-01

    The concept of large-radius multistage coaxial cyclotrons having separated orbits is described, to generate proton beams of 120-2000 MeV energy at tens of GW pulsed and hundreds of MW in continuous beam power operation. Accelerated beam losses must be less than 0.1 W/m for the intercepted average beam power linear density. The concept is inherently configured to actively compensate the longitudinal and transverse space charge expansion in beam bunches. These are based on (1) actively varying the bunch acceleration equilibrium phase while maintaining isochronism, independently for each cyclotron turns; (2) independently changing the acceleration voltage for each turn together with orbit corrections that preserve isochronism; (3) independently changing the transverse betatron oscillation tune shift, to assure non-resonant operation. Also, (4) sextupole lenses are included to compensate for chromaticity effects. Moreover, the concept is based on optimum uses of practical successful results so far achieved in bea...

  16. The First On-line Radioactive Ion Beam from BRIF

    Institute of Scientific and Technical Information of China (English)

    CUI; Bao-qun; MA; Ying-jun; MA; Rui-gang; TANG; Bing; HUANG; Qing-hua; CHEN; Li-hua; MA; Xie

    2015-01-01

    Many of the reactions fundamentally important in nuclear physics and astrophysics can only be studied with high energy radioactive ion beams (RIBs).Radioactive ion beams offer unique opportunities to further our knowledge about the structure of the nucleus,the stellar processes.

  17. Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kurashima, Satoshi, E-mail: kurashima.satoshi@jaea.go.jp; Miyawaki, Nobumasa; Kashiwagi, Hirotsugu; Okumura, Susumu [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Taguchi, Mitsumasa [Quantum Beam Science Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Fukuda, Mitsuhiro [Research Center for Nuclear Physics, Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan)

    2015-07-15

    The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method.

  18. Cerenkov and cyclotron Cerenkov instabilities in a dielectric loaded parallel plate waveguide sheet electron beam system

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Ding; Ding Yaogen [Key Laboratory of High Power Microwave Sources and Technologies, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190 (China)

    2011-09-15

    A dielectric loaded parallel plate waveguide sheet electron beam system can be taken as a reliable model for the practical dielectric loaded rectangular waveguide sheet beam system that has a transverse cross section with a large width to height ratio. By using kinetic theory, the dispersion equations for Cerenkov and cyclotron Cerenkov instabilities in the parallel plate waveguide sheet beam system have been obtained rigorously. The dependences of the growth rate of both instabilities on the electric and structural parameters have also been investigated in detail through numerical calculations. It is worthwhile to point out that adopting an electron beam with transverse velocity can evidently improve the growth rate of Cerenkov instability, which seems like the case of cyclotron Cerenkov instability.

  19. Production of a highly charged uranium ion beam with RIKEN superconducting electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Higurashi, Y.; Ohnishi, J.; Nakagawa, T.; Haba, H.; Fujimaki, M.; Komiyama, M.; Kamigaito, O. [RIKEN Nishina Center, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); Tamura, M.; Aihara, T.; Uchiyama, A. [SHI Accelerator Service Ltd., 1-17-6 Osaki, Shinagawa, Tokyo 141-0032 (Japan)

    2012-02-15

    A highly charged uranium (U) ion beam is produced from the RIKEN superconducting electron cyclotron resonance ion source using 18 and 28 GHz microwaves. The sputtering method is used to produce this U ion beam. The beam intensity is strongly dependent on the rod position and sputtering voltage. We observe that the emittance of U{sup 35+} for 28 GHz microwaves is almost the same as that for 18 GHz microwaves. It seems that the beam intensity of U ions produced using 28 GHz microwaves is higher than that produced using 18 GHz microwaves at the same Radio Frequency (RF) power.

  20. Measurement of the Beam Size and Emittance for the CRC Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae Hoon; Kim, Yu Seok [Dongguk University, Gyeongju (Korea, Republic of)

    2012-05-15

    The purpose of the present study was to confirm beam property for regional Cyclotron Research Center (CRC) installed at Chosun University Hospital. The regional CRC has been developed to produce radioisotope for positron emission tomography (PET). The original radioisotope production cyclotron had a large beam size, which need to be reduced by collimator. In order to construct the proton-induced X-ray emission and proton-induced gamma-ray emission (PIXE-PIGE) beam line, ion beam will be transported to PIXE-PIGE chamber that we have identified the beam size decreased by collimator and beam emittance. There are several methods to measure the emittace, such as the slit and collector method, the pepper-pot method, and the quad scan method. These methods use a slit and monitor to measure the beam profiles, which depend on the field gradient of the quadrupole magnet. In this study, we did not use magnet and monitor. The emittance calculation based on simulated data by previously proven program is approached to consider various methods. Beam emittance was calculated in two methods. The two methods were classical method and ion beam position with divergence method. We found that the beam sizes of x, y-direction are reduced very well

  1. Cyclotrons: 1978

    Energy Technology Data Exchange (ETDEWEB)

    Martin, J.A. (comp.)

    1978-01-01

    A compilation is presented of the experimental facilities of the world's cyclotrons including history and status, staff and operation, research staff, target facilities, magnet, acceleration system, vacuum system, characteristic beams, beam properties, and a plan view of the facility for each cyclotron. (GHT)

  2. The design and construction of a pulsed beam generation system based on high intensity cyclotron

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    In order to perform the studies on a pulsed beam generation system based on a high intensity cyclotron, a test beam line with a pulsed beam generation for a 10 MeV compact cyclotron (CYCIAE-10) has been designed and constructed at China Institute of Atomic Energy (CIAE). A 70 MHz continuous H- beam can be pulsed to the pulse length of less than 10 ns with a repetition rate of 4.4 MHz. The sine waveform with a frequency of 2.2 MHz is adopted for the chopper and a mesh structure with single drift and dual gaps is used for the 70 MHz buncher. A helical resonator is designed and constructed based on simulations and experiments on the RF matching for the chopper. A helical inductance loop that is exceptionally large of its kind and equipped with water cooling for the resonator has been successfully wound and a 500 W solid RF amplifier has been manufactured. A special measuring device has been designed, which can be used to measure both the DC beam and the pulsed beam. The required pulsed beam was obtained after pulsed beam tuning.

  3. Accelerator and detector physics at the Bern medical cyclotron and its beam transport line

    Directory of Open Access Journals (Sweden)

    Auger Martin

    2016-03-01

    Full Text Available The cyclotron laboratory for radioisotope production and multi-disciplinary research at the Bern University Hospital (Inselspital is based on an 18-MeV proton accelerator, equipped with a specifically conceived 6-m long external beam line, ending in a separate bunker. This facility allows performing daily positron emission tomography (PET radioisotope production and research activities running in parallel. Some of the latest developments on accelerator and detector physics are reported. They encompass novel detectors for beam monitoring and studies of low current beams.

  4. Magnetic fields and beam optics studies of a 250 MeV superconducting proton radiotherapy cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Won [Research Institute and Hospital, National Cancer Center, 809 Madu-dong, Koyang, Kyonggi (Korea, Republic of)], E-mail: jwkim@ncc.re.kr

    2007-11-21

    A 250 MeV superconducting cyclotron for the proton radiation therapy was designed at the Michigan State University (MSU) for use at the Paul Scherrer Institut. This work was based on the conceptual design carried out at the MSU in 1994. The previous design was refined to finalize the magnet configuration and to optimally arrange cyclotron elements for the actual construction. The spiral angle of the pole was reduced, the new hill-edges and valley shims being introduced. The magnetic fields were highly isochronized using a least square fitting routine involving a schematic shimming scheme. The resulting reference field was adequate for the elaborate study of beam optics. The optics simulation predicted that extraction efficiency of above 80% was achievable for a beam with the initial phase width of 20{sup o}. The vertical deflector was investigated located in the central region to control the beam intensity with tracking of beam phase spaces. Some measurement results for the constructed cyclotron were found in a good agreement with those of the optics study.

  5. Electron Cloud Cyclotron Resonances in the Presence of a Short-bunch-length Relativistic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Celata, C.M.; Furman, Miguel A.; Vay, J.-L.; Yu, Jennifer W.

    2008-09-02

    Computer simulations using the 2D code"POSINST" were used to study the formation of the electron cloud in the wiggler section of the positron damping ring of the International Linear Collider. In order to simulate an x-y slice of the wiggler (i.e., a slice perpendicular to the beam velocity), each simulation assumed a constant vertical magnetic field. At values of the magnetic field where the cyclotron frequency was an integral multiple of the bunch frequency, and where the field strength was less than approximately 0.6 T, equilibrium average electron densities were up to three times the density found at other neighboring field values. Effects of this resonance between the bunch and cyclotron frequency are expected to be non-negligible when the beam bunch length is much less than the product of the electron cyclotron period and the beam velocity, for a beam moving at v~;;c. Details of the dynamics of the resonance are described.

  6. Analytic fluid theory of beam spiraling in high-intensity cyclotrons

    Directory of Open Access Journals (Sweden)

    A. J. Cerfon

    2013-02-01

    Full Text Available Using a two-dimensional fluid description, we investigate the nonlinear radial-longitudinal dynamics of intense beams in isochronous cyclotrons in the nonrelativistic limit. With a multiscale analysis separating the time scale associated with the betatron motion and the slower time scale associated with space-charge effects, we show that the longitudinal-radial vortex motion can be understood in the frame moving with the charged beam as the nonlinear advection of the beam by the E×B velocity field, where E is the electric field due to the space charge and B is the external magnetic field. This interpretation provides simple explanations for the stability of round beams and for the development of spiral halos in elongated beams. By numerically solving the nonlinear advection equation for the beam density, we find that it is also in quantitative agreement with results obtained in particle-in-cell simulations.

  7. Visualization and on line monitoring of geometric parameters of beams at KSRS

    CERN Document Server

    Ioudin, L; Potlovsky, K; Rezvov, V

    2001-01-01

    On the basis of developed hardware and software we investigate the opportunity of on line registration of geometric parameters of low intensity SR beam and electron beams in single shot mode. Ionization and luminescence detectors form real optic image of a beam cross section. The image is registered by a TV camera, digitized and processed by a computer. Gray scale image and profiles of a beam are represented. Accumulation and statistic processing of the data give the possibility to increase the sensitivity of the hardware and to calculate the average position of the beam gravity center, dispersion and statistic uncertainty.

  8. Steerable beam systems for electron cyclotron resonance heating

    Energy Technology Data Exchange (ETDEWEB)

    Colborn, J.

    1985-08-31

    Several methods are discussed for steering a 200 kW pencil beam of electromagnetic waves in the 60 GHz to 200 GHz frequency range. These include methods incorporating swivelling mirrors, phased arrays, mode converters, and optical materials. It is found that for the near term, the mechanical systems are best, capable of steering times of 3 ms to 100 ms and losses of less than 5%. Optical methods, as yet virtually uninvestigated, appear to offer the only means of beam-steering in the 5..mu..s to 100..mu..s range necessary for MHD mode tracking.

  9. Note: Production of a mercury beam with an electron cyclotron resonance ion source.

    Science.gov (United States)

    Vondrasek, R; Pardo, R; Scott, R

    2013-11-01

    An electron cyclotron resonance ion source has been utilized to produce mercury beams with intensities of 4.5 eμA of (202)Hg(29+) and 3.0 eμA of (202)Hg(31+) from natural abundance mercury metal. The production technique relies on the evaporation of liquid mercury into the source plasma vacuum region and utilizes elemental mercury instead of a volatile organic compound as the neutral feed material.

  10. Parallel Beam Dynamics Code Development for High Intensity Cyclotron

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>1 Parallel PIC algorithm Self field solver is the key part of a high intensity beam dynamic PIC code which usually adopts the P-M (Particle-Mesh) method to solve the space charge. The P-M method is composed of four major

  11. The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector

    Science.gov (United States)

    Braccini, Saverio

    2013-04-01

    The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few μA for radioisotope production, as well as for both pulsed and continuous beams.

  12. The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector

    Energy Technology Data Exchange (ETDEWEB)

    Braccini, Saverio [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland)

    2013-04-19

    The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few {mu}A for radioisotope production, as well as for both pulsed and continuous beams.

  13. Scattering of diffracting beams of electron cyclotron waves by random density fluctuations in inhomogeneous plasmas

    Science.gov (United States)

    Weber, Hannes; Maj, Omar; Poli, Emanuele

    2015-03-01

    The physics and first results of the new WKBeam code for electron cyclotron beams in tokamak plasmas are presented. This code is developed on the basis of a kinetic radiative transfer model which is general enough to account for the effects of diffraction and density fluctuations on the beam. Our preliminary numerical results show a significant broadening of the power deposition profile in ITER due to scattering from random density fluctuations at the plasma edge, while such scattering effects are found to be negligible in medium-size tokamaks like ASDEX upgrade.

  14. Study of ion beam transport from the SECRAL electron cyclotron resonance ion source at the Institute of Modern Physics.

    Science.gov (United States)

    Cao, Y; Lu, W; Zhang, W H; Sha, S; Yang, Y; Ma, B H; Wang, H; Zhu, Y H; Guo, J W; Fang, X; Lin, S H; Li, X X; Feng, Y C; Li, J Y; Zhao, H Y; Ma, H Y; Zhang, X Z; Guo, X H; Wu, Q; Sun, L T; Zhao, H W; Xie, D Z

    2012-02-01

    Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper.

  15. Beam tracking simulation in the central region of a 13 MeV PET cyclotron

    Science.gov (United States)

    Anggraita, Pramudita; Santosa, Budi; Taufik, Mulyani, Emy; Diah, Frida Iswinning

    2012-06-01

    This paper reports the trajectories simulation of proton beam in the central region of a 13 MeV PET cyclotron, operating with negative proton beam (for easier beam extraction using a stripper foil), 40 kV peak accelerating dee voltage at fourth harmonic frequency of 77.88 MHz, and average magnetic field of 1.275 T. The central region covers fields of 240mm × 240mm × 30mm size at 1mm resolution. The calculation was also done at finer 0.25mm resolution covering fields of 30mm × 30mm × 4mm size to see the effects of 0.55mm horizontal width of the ion source window and the halted trajectories of positive proton beam. The simulations show up to 7 turns of orbital trajectories, reaching about 1 MeV of beam energy. The distribution of accelerating electric fields and magnetic fields inside the cyclotron were calculated in 3 dimension using Opera3D code and Tosca modules for static magnetic and electric fields. The trajectory simulation was carried out using Scilab 5.3.3 code.

  16. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    Energy Technology Data Exchange (ETDEWEB)

    Thomae, R., E-mail: rthomae@tlabs.ac.za; Conradie, J.; Fourie, D.; Mira, J.; Nemulodi, F. [iThemba LABS, P.O. Box 722, Somerset West 7130 (South Africa); Kuechler, D.; Toivanen, V. [CERN, BE/ABP/HSL, 1211 Geneva 23 (Switzerland)

    2016-02-15

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  17. The influence of the edge density fluctuations on electron cyclotron wave beam propagation in tokamaks

    DEFF Research Database (Denmark)

    Bertelli, N.; Balakin, A.A.; Westerhof, E.

    2010-01-01

    A numerical analysis of the electron cyclotron (EC) wave beam propagation in the presence of edge density fluctuations by means of a quasi-optical code [Balakin A. A. et al, Nucl. Fusion 48 (2008) 065003] is presented. The effects of the density fluctuations on the wave beam propagation...... are estimated in a vacuum beam propagation between the edge density layer and the EC resonance absorption layer. Consequences on the EC beam propagation are investigated by using a simplified model in which the density fluctuations are described by a single harmonic oscillation. In addition, quasi......-optical calculations are shown by using edge density fluctuations as calculated by two-dimensional interchange turbulence simulations and validated with the experimental data [O. E. Garcia et al, Nucl. Fusion 47 (2007) 667]...

  18. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS.

    Science.gov (United States)

    Thomae, R; Conradie, J; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V

    2016-02-01

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  19. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    Science.gov (United States)

    Thomae, R.; Conradie, J.; Fourie, D.; Mira, J.; Nemulodi, F.; Kuechler, D.; Toivanen, V.

    2016-02-01

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  20. On-Line Bunch Tomography and Beam Modelling for MTE Commissioning

    CERN Document Server

    Rothe, Johannes

    2015-01-01

    For my stay as a CERN Summer Student from June 29 to September 25, 2015, I worked with Guido Sterbini of the Accelerator and Beam Physics group. I was based in the CERN Control Center (CCC) at the Prevessin Site, and supported the ongoing beam commissioning work on Multi-Turn Extraction through the development of on-line monitoring and control tools for the Proton Synchrotron (PS) machine.

  1. Simulations of Beam Quality in a 13 MeV PET Cyclotron

    Directory of Open Access Journals (Sweden)

    A. Pramudita

    2015-12-01

    Full Text Available Simulation of the trajectories of negative hydrogen ion (H− beam in a 13 MeV PET cyclotron (DECY-13 were carried out by using the Runge-Kutta (RK4 approximation method and Scilab 5.4.1. The magnetic and electric fields were calculated using Opera-3d/TOSCA softwares at 1 mm resolution. The cyclotron is of a fourth-harmonics type, meaning that the acceleration occurs four times per cycle, with a radiofrequency (RF field of 77.66 MHz frequency and 40 kV amplitude. The calculations and simulations show that the maximum distance between the ion source and the puller is about 6 mm, while the maximum width of the beam at 13 MeV is about 10 mm, and the initial phase between the RF field and the beam ranges from -10° to 10°, with a yield of about 10% of the beam from the ion source getting accelerated to 13 MeV.

  2. Numerical Simulations of Nonlinear Dynamics of Electron Cyclotron Maser with a Straight Beam

    Institute of Scientific and Technical Information of China (English)

    KONG Ling-Bao; HOU Zhi-Ling

    2011-01-01

    An electron cyclotron maser based on anomalous Doppler effect (ADECM) with an initially axial beam velocity is considered,and the nonlinear equation of beam-wave interaction is presented.With the numerical methods,the nonlinear dynamics of the ADECM is investigated.It is shown that the saturated interaction efficiency of the ADECM approaches 90% and the interaction length for the saturated efficiency spans about 5-20cm.The results may be of importance for designing a compact device in applications in microwave generations or microwave heating of ceramic laminates.In the late 1950s,the theoretical studies on the instability of electron cyclotron maser based on normal Doppler effect (NDECM) were performed almost simultaneously by Gaponov,[1] Twiss,[2] and Schneider.[3] Their discoveries have resulted in the most successful fast-wave devices such as the gyrotron and variants.[4,5] The possible applications of microwaves span a wide range of technologies such as in thermonuclear fusion energy,charged particle accelerations,radar systems,and processing of advanced ceramics.[6-16]%An electron cyclotron maser based on anomalous Doppler effect (ADECM) with an initially axial beam velocity is considered, and the nonlinear equation of beam-wave interaction is presented. With the numerical methods, the nonlinear dynamics of the ADECM is investigated. It is shown that the saturated interaction efficiency of the ADECM approaches 90% and the interaction length for the saturated efficiency spans about 5-20 cm. The results may be of importance for designing a compact device in applications in microwave generations or microwave heating of ceramic laminates.

  3. Experimental observation of acoustic emissions generated by a pulsed proton beam from a hospital-based clinical cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Kevin C.; Solberg, Timothy D.; Avery, Stephen, E-mail: Stephen.Avery@uphs.upenn.edu [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Vander Stappen, François; Janssens, Guillaume; Prieels, Damien [Ion Beam Applications SA, Louvain-la-Neuve 1348 (Belgium); Bawiec, Christopher R.; Lewin, Peter A. [School of Biomedical Engineering, Drexel University, Philadelphia, Pennsylvania 19104 (United States); Sehgal, Chandra M. [Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2015-12-15

    Purpose: To measure the acoustic signal generated by a pulsed proton spill from a hospital-based clinical cyclotron. Methods: An electronic function generator modulated the IBA C230 isochronous cyclotron to create a pulsed proton beam. The acoustic emissions generated by the proton beam were measured in water using a hydrophone. The acoustic measurements were repeated with increasing proton current and increasing distance between detector and beam. Results: The cyclotron generated proton spills with rise times of 18 μs and a maximum measured instantaneous proton current of 790 nA. Acoustic emissions generated by the proton energy deposition were measured to be on the order of mPa. The origin of the acoustic wave was identified as the proton beam based on the correlation between acoustic emission arrival time and distance between the hydrophone and proton beam. The acoustic frequency spectrum peaked at 10 kHz, and the acoustic pressure amplitude increased monotonically with increasing proton current. Conclusions: The authors report the first observation of acoustic emissions generated by a proton beam from a hospital-based clinical cyclotron. When modulated by an electronic function generator, the cyclotron is capable of creating proton spills with fast rise times (18 μs) and high instantaneous currents (790 nA). Measurements of the proton-generated acoustic emissions in a clinical setting may provide a method for in vivo proton range verification and patient monitoring.

  4. External beam's nozzle design for the CRC cyclotron PIXE/PIGE

    Science.gov (United States)

    Choi, Yeon-Gyeong; Kim, Yu-Seok

    2015-02-01

    Recently, 13-MeV proton cyclotrons have been applied to non-destructive trace element analytical techniques, such as proton-induced X-ray emission (PIXE) and proton-induced gamma-ray emission (PIGE). A new extended beam line has been designed for PIXE/PIGE measurements in order to deliver protons to the target with minimal losses, thus reducing secondary radiation. A target chamber for PIXE/PIGE measurements is installed at the end of the extended beam line, and the beam size may be optimized by using a series of collimators that are located in front of the target. The optimized proton beam, with low currents (˜nA) for PIXE/PIGE experiments, requires a small beam size with variable energies from ˜10 keV to 3 MeV. Based on the ionization cross-section curve, a 3-MeV proton beam has been determined to be suitable for PIXE/PIGE measurements. Therefore, the 13-MeV protons extracted from the cyclotron must be reduced to 3 MeV, and this is achieved through the incorporation of an energy degrader. The appropriate thickness of the energy degrader has been estimated by using the stopping range in matter (SRIM) program. Also, suitable materials must be used for the construction of the collimator and the energy degrader in order to meet the requirements of low neutron activation due to the application of protons. In this study, we evaluated a number of suitable materials with low neutron yields and with little energy spread as the beam passes through the energy degrader and collimator. The appropriate thickness of the energy degrader for the reduction of the proton energy from 13 MeV to 3 MeV was determined using the SRIM code. Also, the neutron yield at the nozzle was estimated using the MCNPX code.

  5. Chemical investigations of isotope separation on line target units for carbon and nitrogen beams

    CERN Document Server

    Franberg, H; Gäggeler, H W; Köster, U

    2006-01-01

    Radioactive ion beams (RIBs) are of significant interest in a number of applications. Isotope separation on line (ISOL) facilities provide RIB with high beam intensities and good beam quality. An atom that is produced within the ISOL target will first diffuse out from the target material. During the effusion towards the transfer line and into the ion source the many contacts with the surrounding surfaces may cause unacceptable delays in the transport and, hence, losses of the shorter-lived isotopes. We performed systematic chemical investigations of adsorption in a temperature and concentration regime relevant for ISOL targets and ion source units, with regard to CO/sub x/ and NOmaterials are potential construction materials for the above-mentioned areas. Off-line and on-line tests have been performed using a gas thermochromatography setup with radioactive tracers. The experiments were performed at the production of tracers for atmospheric chemistry (PROTRAC) facility at the Paul Schener Institute in Villigen...

  6. On-line Observation Of Electron Beam Bunches In The Large Storage Ring Of Kurchatov Srs

    CERN Document Server

    Ioudin, L I; Krylov, Y V; Rezvov, V A; Stirin, A I; Valentinov, A G; Yupinov, Y L

    2004-01-01

    A complex of instrumentation for visual quantitative estimation of electron beam bunches in the big storage ring of Kurchatov Synchrotron Radiation Centre (KSRC) is tested. The bunches pass through a cylindrical electrostatic sensor whose signal is recorded by a wide-band oscillograph. The TV camera reads the optical image of the signal from the oscillograph screen. The TV signal numbering board inputs the video image to the computer memory. The monitor displays the beam bunch structure. A special program provides on-line visualisation of bunch behaviour on the beam orbit. The images of beam structure and a series of images showing the beam behaviour in the regimes of accumulation, acceleration and in the stationary regime a full power are numbered and stored.

  7. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Science.gov (United States)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Lu, W.; Xie, D. Z.; Hitz, D.; Zhang, X. Z.; Yang, Y.

    2017-09-01

    The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24-28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of 40Ar+ and 129Xe26+ have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL), China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24 +18 GHz ) heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  8. Beam imaging in the injection line of the INFN-LNS superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Nicolosi, Dario, E-mail: dario.nicolosi@lns.infn.it; Cosentino, Luigi; Mascali, David; Pappalardo, Alfio; Castro, Maurizio; Celona, Luigi; Marchetta, Carmelo; Marletta, Salvatore; Maugeri, Antonio; Rifuggiato, Danilo; Seminara, Angelo; Gammino, Santo [INFN-Laboratori Nazionali del Sud, Via S. Sofia 62, 95123 Catania (Italy)

    2016-02-15

    A cheap and efficient diagnostic system for beam monitoring has been recently developed at INFN-LNS in Catania. It consists of a high sensitivity CCD camera detecting the light produced by an ion beam hitting the surface of a scintillating screen and a frame grabber for image acquisition. A scintillating screen, developed at INFN-LNS and consisting of a 2 μm BaF{sub 2} layer evaporated on an aluminium plate, has been tested by using {sup 20}Ne and {sup 40}Ar beams in the keV energy range. The CAESAR ECR ion source has been used for investigating the influence of the frequency and magnetic field tuning effects, the impact of the microwave injected power, and of the focusing solenoids along the low energy beam transport on the beam shape and current. These tests will allow to better understand the interplay between the plasma and beam dynamics and, moreover, to improve the transport efficiency along the low energy beam line and the matching with the superconducting cyclotron, particularly relevant in view of the expected upgrade of the machine.

  9. Direct measurement of refracted trajectory of transmitting electron cyclotron beam through plasma on the Large Helical Device

    Directory of Open Access Journals (Sweden)

    Takahashi Hiromi

    2015-01-01

    Full Text Available The electron-cyclotron (EC -beam refraction due to the presence of plasma was investigated in the Large Helical Device. The transmitted-EC-beam measurement system was constructed and the beam pattern on the opposite side of the irradiated surface was measured using an IR camera. Clear dependence of the EC-beam refraction on the electron density was observed and the beam shift in the toroidal direction showed good agreement with the ray-trace calculation of TRAVIS. The influence of the peripheral density profile and the thermal effect on the beam refraction were discussed.

  10. A PIXE mini-beam setup at the bonn cyclotron for archeometric metal analyses

    Science.gov (United States)

    Weber, J.; Beier, Th.; Diehl, U.; Lambrecht, D.; Mommsen, H.; Pantenburg, F. J.

    1990-04-01

    The exact analysis of the elemental composition at and around a soldering joint of an antique piece of jewelry can elucidate the joining technologies and give hints of the genuineness of the object. As analytical method we use PIXE, which is nondestructive, multielemental and with fundamental parameter calculations gives absolute concentration values. To obtain the necessary spot size of the H 2+ beam at the Bonn cyclotron we use a piezo-controlled diaphragm, whose demagnified image is focussed on the target by two magnetic quadrupole triplets. With an electrostatic deflector the beam spot of 0.1 × 0.3 mm 2 size can be moved 2 mm in each direction on the target. With a laser beam, which simulates the ion beam, an irregularly shaped archeological object can be positioned. The laser is also used to obtain the alignment of the target surface to the ion beam direction and the small beam size makes it easier to find a flat part on the surface of the object; both of these are important preconditions for using the fundamental parameter method. A scan over a joint of modern gold alloys demonstrates the ability to detect soldering joints. The analysis of four pieces of Roman gold jewelry found in the area of Cologne and Bonn shows examples of brazing with a solder as well as diffusion soldering.

  11. On-line beam monitoring for neutron capture therapy at the MIT Research Reactor

    Science.gov (United States)

    Harling, Otto K.; Moulin, Damien J.; Chabeuf, Jean-Michel; Solares, Guido R.

    1995-08-01

    Neutron capture therapy sets new requirements on the measurement and monitoring of the radiation fields used in this new form of therapy. Beams used for neutron capture therapy are comprised of mixed radiation fields which include slow, epithermal, and fast neutrons, as well as gamma rays. A computer-based beam monitoring system for epithermal or thermal neutron capture therapy is described. This system provides accurate, sensitive, and rapid on-line readout and recording of the various beam components. Readout of fluxes, fluences, and corresponding doses in the target are provided in color coded graphic analog as well as numerical form on the computer monitors. Variations in neutron spectrum or spatial distribution of the beam can be rapidly diagnosed with the aid of the monitor readout. Redundancy of fluence measurement is provided by an independent system using scalers and timers and by utilizing reactor power measuring instruments.

  12. Advances in intense beams, beam delivery, targetry, and radiochemistry at advanced cyclotron systems

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.R. [Advanced Cyclotron Systems Inc., 7851 Alderbridge Way, Richmond, BC, V6X 2A4 (Canada)]. E-mail: djohnson@advancedcyclotron.com; Watt, R. [Advanced Cyclotron Systems Inc., 7851 Alderbridge Way, Richmond, BC, V6X 2A4 (Canada); Kovac, B. [Advanced Cyclotron Systems Inc., 7851 Alderbridge Way, Richmond, BC, V6X 2A4 (Canada); Zyuzin, A. [Advanced Cyclotron Systems Inc., 7851 Alderbridge Way, Richmond, BC, V6X 2A4 (Canada); Van Lier, E. [Advanced Cyclotron Systems Inc., 7851 Alderbridge Way, Richmond, BC, V6X 2A4 (Canada); Erdman, K.L. [Advanced Cyclotron Systems Inc., 7851 Alderbridge Way, Richmond, BC, V6X 2A4 (Canada); Gyles, Wm. [Advanced Cyclotron Systems Inc., 7851 Alderbridge Way, Richmond, BC, V6X 2A4 (Canada); Sabaiduc, V. [Advanced Cyclotron Systems Inc., 7851 Alderbridge Way, Richmond, BC, V6X 2A4 (Canada); McQuarrie, S.A. [Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, T6G 1Z2 (Canada); Wilson, J. [Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, T6G 1Z2 (Canada); Backhouse, C. [Department of Electrical Engineering, University of Alberta, Edmonton, AB (Canada); Gelbart, Wm. [Advanced System Design, C22, S6, RR1, Garden Bay, BC, V0N 1S0 (Canada); Kuo, T. [4654 N. Larwin Ave., Concorde, CA 94521 United States (United States)

    2007-08-15

    The increasing demand for radionuclides for PET and SPECT has resulted in ACSI system improvements starting from the cyclotron and proceeding to the Radiochemistry Modules. With more TR30 cyclotrons installed and operating at full capacity, emphasis has been placed on improving the operational components to reduce both the incidence of failure and subsequent maintenance time. A cyclotron system has been developed that meets the needs of a regional radiopharmacy that supplies both positron and single photon emitters that would not otherwise be available. This new system has been named the TR24. In order to deal with some of the challenges of high currents, a method has been developed for passivating the entrance window foil during high current irradiation of a water target used to produce F-18. A method has been developed for passivating the entrance window foil to reduce unwanted chemical species that interfere with radiopharmaceutical production. Preliminary results for novel radioiodine production technique using the TR19/9 are also discussed.

  13. In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study

    Science.gov (United States)

    Shao, Yiping; Sun, Xishan; Lou, Kai; Zhu, Xiaorong R.; Mirkovic, Dragon; Poenisch, Falk; Grosshans, David

    2014-07-01

    We developed and investigated a positron emission tomography (PET) system for use with on-line (both in-beam and intra-fraction) image-guided adaptive proton therapy applications. The PET has dual rotating depth-of-interaction measurable detector panels by using solid-state photomultiplier (SSPM) arrays and LYSO scintillators. It has a 44 mm diameter trans-axial and 30 mm axial field-of-view (FOV). A 38 mm diameter polymethyl methacrylate phantom was placed inside the FOV. Both PET and phantom axes were aligned with a collimated 179.2 MeV beam. Each beam delivered ˜50 spills (0.5 s spill and 1.5 s inter-spill time, 3.8 Gy at Bragg peak). Data from each beam were acquired with detectors at a given angle. Nine datasets for nine beams with detectors at nine different angles over 180° were acquired for full-tomographic imaging. Each dataset included data both during and 5 min after irradiations. The positron activity-range was measured from the PET image reconstructed from all nine datasets and compared to the results from simulated images. A 22Na disc-source was also imaged after each beam to monitor the PET system's performance. PET performed well except for slight shifts of energy photo-peak positions (PET with high sensitivity and uniform resolution. Sub-mm activity-ranges were achieved with minimal 6 s acquisition time and three spill irradiations. These results indicate the feasibility of PET for intra-fraction beam-range verification. Further studies are needed to develop and apply a novel clinical PET system for on-line image-guided adaptive proton therapy.

  14. Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN.

    Science.gov (United States)

    Toivanen, V; Küchler, D

    2016-02-01

    The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

  15. Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

    Energy Technology Data Exchange (ETDEWEB)

    Toivanen, V., E-mail: ville.aleksi.toivanen@cern.ch; Küchler, D. [European Organization for Nuclear Research (CERN), 1211 Geneva 23 (Switzerland)

    2016-02-15

    The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

  16. Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

    Science.gov (United States)

    Toivanen, V.; Küchler, D.

    2016-02-01

    The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

  17. Production of electron cyclotron resonance plasma by using multifrequencies microwaves and active beam profile control on a large bore electron cyclotron resonance ion source with permanent magnets.

    Science.gov (United States)

    Kato, Yushi; Watanabe, Takeyoshi; Matsui, Yuuki; Hirai, Yoshiaki; Kutsumi, Osamu; Sakamoto, Naoki; Sato, Fuminobu; Iida, Toshiyuki

    2010-02-01

    A new concept on magnetic field with all magnets on plasma production and confinement has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure. The magnetic field configuration is constructed by a pair of magnets assembly, i.e., comb-shaped magnet which cylindrically surrounds the plasma chamber. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequencies are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequencies microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

  18. On-line neutron beam monitoring of the Finnish BNCT facility

    Science.gov (United States)

    Tanner, Vesa; Auterinen, Iiro; Helin, Jori; Kosunen, Antti; Savolainen, Sauli

    1999-02-01

    A Boron Neutron Capture Therapy (BNCT) facility has been built at the FiR 1 research reactor of VTT Chemical Technology in Espoo, Finland. The facility is currently undergoing dosimetry characterisation and neutron beam operation research for clinical trials. The healthy tissue tolerance study, which was carried out in the new facility during spring 1998, demonstrated the reliability and user-friendliness of the new on-line beam monitoring system designed and constructed for BNCT by VTT Chemical Technology. The epithermal neutron beam is monitored at a bismuth gamma shield after an aluminiumfluoride-aluminium moderator. The detectors are three pulse mode U 235-fission chambers for epithermal neutron fluence rate and one current mode ionisation chamber for gamma dose rate. By using different detector sensitivities the beam intensity can be measured over a wide range of reactor power levels (0.001-250 kW). The detector signals are monitored on-line with a virtual instrumentation (LabView) based PC-program, which records and displays the actual count rates and total counts of the detectors in the beam. Also reactor in-core power instrumentation and control rod positions can be monitored via another LabView application. The main purpose of the monitoring system is to provide a dosimetric link to the dose in a patient during the treatment, as the fission chamber count rates have been calibrated to the induced thermal neutron fluence rate and to the absorbed dose rate at reference conditions in a tissue substitute phantom.

  19. Proton heating and beam formation via parametrically unstable Alfven-cyclotron waves

    Science.gov (United States)

    Marsch, Eckart; Araneda, Jaime; -Vinas, Adolfo F.

    Vlasov theory and one-dimensional hybrid simulations are used to study the effects that compressible fluctuations driven by parametric instabilities of Alfvén/cyclotron waves have on proe ton velocity distributions. Field-aligned proton beams are generated during the saturation phase of the wave-particle interaction, with a drift speed which is slightly greater than the Alfvén speed and is maintained until the end of the simulation. The main part of the dise tribution becomes anisotropic due to phase mixing as is typically observed in the velocity distributions measured in the fast solar wind. We identify the key instabilities and also find that even in the parameter regime, where fluid theory appears to be appropriate, strong kinetic effects still prevail.

  20. A new and simple calibration-independent method for measuring the beam energy of a cyclotron.

    Science.gov (United States)

    Gagnon, Katherine; Jensen, Mikael; Thisgaard, Helge; Publicover, Julia; Lapi, Suzanne; McQuarrie, Steve A; Ruth, Thomas J

    2011-01-01

    This work recommends a new and simple-to-perform method for measuring the beam energy of an accelerator. The proposed method requires the irradiation of two monitor foils interspaced by an energy degrader. The primary advantage of the proposed method, which makes this method unique from previous energy evaluation strategies that employ the use of monitor foils, is that this method is independent of the detector efficiency calibration. This method was evaluated by performing proton activation of (nat)Cu foils using both a cyclotron and a tandem Van de Graaff accelerator. The monitor foil activities were read using a dose calibrator set to an arbitrary calibration setting. Excellent agreement was noted between the nominal and measured proton energies.

  1. A new and simple calibration-independent method for measuring the beam energy of a cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Katherine, E-mail: kgagnon1@ualberta.c [Cross Cancer Institute, Edmonton PET Centre, University of Alberta, Edmonton, AB, T6G 1Z2 (Canada); Jensen, Mikael; Thisgaard, Helge [Hevesy Laboratory, Risoe-DTU, Technical University of Denmark, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Publicover, Julia; Lapi, Suzanne [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada); McQuarrie, Steve A. [Cross Cancer Institute, Edmonton PET Centre, University of Alberta, Edmonton, AB, T6G 1Z2 (Canada); Ruth, Thomas J. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, V6T 2A3 (Canada)

    2011-01-15

    This work recommends a new and simple-to-perform method for measuring the beam energy of an accelerator. The proposed method requires the irradiation of two monitor foils interspaced by an energy degrader. The primary advantage of the proposed method, which makes this method unique from previous energy evaluation strategies that employ the use of monitor foils, is that this method is independent of the detector efficiency calibration. This method was evaluated by performing proton activation of {sup nat}Cu foils using both a cyclotron and a tandem Van de Graaff accelerator. The monitor foil activities were read using a dose calibrator set to an arbitrary calibration setting. Excellent agreement was noted between the nominal and measured proton energies.

  2. This picture was taken in 1967 during the first test of the Isotope On-Line Separator (ISOLDE) installation at the 600 MeV CERN Synchro Cyclotron.

    CERN Multimedia

    CERN PhotoLab

    1967-01-01

    When ISOLDE began operation, it was unique in the world. It used a new technique to overcome the problem of rapidly separating interesting atoms from the rest of the nuclear target. Through a combination of chemical and electromagnetic methods the different isotopes were separated and converted into an ion beam made of just one isotope. On-line production of radioactive nuclei, in this way, offered many new opportunities for physicists as it allowed them to perform previously impossible experiments on short-lived nuclei. ISOLDE has become one of CERN's major installations and it supports a broad scientific programme by providing beams to different experiments. The techniques developed at ISOLDE have opened up a new field of radioactive ion-beam accelerators, both at CERN and worldwide.

  3. A CW radiofrequency ion source for production of negative hydrogen ion beams for cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Kalvas, T.; Tarvainen, O.; Komppula, J.; Koivisto, H.; Tuunanen, J. [University of Jyväskylä, Department of Physics (Finland); Potkins, D.; Stewart, T.; Dehnel, M. P. [D-Pace, Inc., Nelson, B.C. Canada (Canada)

    2015-04-08

    A CW 13.56 MHz radiofrequency-driven ion source RADIS for production of H{sup −} and D{sup −} beams is under development for replacing the filament-driven ion source of the MCC30/15 cyclotron. The RF ion source has a 16-pole multicusp plasma chamber, an electromagnet-based magnetic filter and an external planar spiral RF antenna behind an AlN window. The extraction is a 5-electrode system with an adjustable puller electrode voltage for optimizing the beam formation, a water-cooled electron dump electrode and an accelerating einzel lens. At 2650 W of RF power, the source produces 1 mA of H{sup −} (2.6 mA/cm{sup 2}), which is the intensity needed at injection for production of 200 µA H{sup +} with the filament-driven ion source. A simple pepperpot device has been developed for characterizing the beam emittance. Plans for improving the power efficiency with the use of a new permanent magnet front plate is discussed.

  4. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    CMS Collaboration

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hard sensors. Inside CMS two rings instrumented with 12 single crystal diamond sensors each are installed on both sides of the interaction point. The sensors are subdivided in two pads, and each pad is read out by a dedicated fast radiation hard ASIC in 130 nm CMOS technology. Due to the excellent time resolution collision products will be separated from machine induced background. In the backend a dead-time less histogramming unit is used, and a fast microTCA system with GHz sampling rate is under development. The detector will measure both the on-line luminosity and the background bunch-by-bunch. The performance of a prototype detector in a test-beam will be reported, and results from the operation during data taking will be presented.

  5. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    Karacheban, Olena

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hardsensors. Inside CMS two rings instrumented with 12 single crystal diamondsensors each are installed on both sides of the interaction point. Thesensors are subdivided in two pads, and each pad is read out by adedicated fast radiation hard ASIC in 130 nm CMOS technology.Due to the excellent time resolution collision products will be separatedfrom machine induced background. In the backend a dead-time lesshistogramming unit is udsed, and a fast microTCA system with GHz samplingrate is under development.The detector will measure both the on-line luminosity and the backgroundbunch-by-bunch.The performance of a prototype detector in a test-beam will be reported,and results from the operation during data taking will be presented.

  6. Formation of multi-charged ion beams by focusing effect of mid-electrode on electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Imai, Youta, E-mail: imai@nf.eie.eng.osaka-u.ac.jp; Kimura, Daiju; Kurisu, Yosuke; Nozaki, Dai; Yano, Keisuke; Kumakura, Sho; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki [Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2014-02-15

    We are constructing a tandem type electron cyclotron resonance ion source (ECRIS) and a beam line for extracting ion beams. The ion beam is extracted from the second stage by an accel-decel extraction system with a single-hole and the ion beam current on each electrode is measured. The total ion beam current is measured by a faraday cup downstream the extraction electrodes. We measure these currents as a function of the mid-electrode potential. We also change the gap length between electrodes and perform similar measurement. The behaviors of these currents obtained experimentally against the mid-electrode potential show qualitatively good agreement with a simple theoretical consideration including sheath potential effects. The effect of mid-electrode potential is very useful for decreasing the beam loss for enhancing ion beam current extracted from ECRIS.

  7. On-line Scanned Probe Microscopy Transparently Integrated with DualBeam SEM/FIB Systems

    Science.gov (United States)

    Ignatov, Andrey; Komissar, Anatoly; Lewis, Aaron

    2013-03-01

    A multifunctional scanning probe microscope (SPM) will be described that transparently integrates with a DualBeam SEM/FIB System. This is done without perturbing any of the capabilities of the Dual Beam in terms of detectors, gas injectors, analyzers etc while allowing for a completely exposed probe tip to be imaged online even with immersion objectives at working distances as short as 4 mm. In addition, the completely free motion of the rotation axis of the stage is maintained with the probe tip at the eucentric point, this makes it possible to orient the sample in any direction on any structure The X and Y scan range of the atomic force microscopic (AFM) imaging achieves 35 microns with rough motion over 10 millimeters. This permits the SPM to tilt into position perpendicular to the SEM or FIB or under an angle for rapid and accurate placement of the probe tip at or on structures such as biopolymeric materials that are nanometric in X, Y and Z extent. Thus, not only can a structure's nanometric height be accurately profiled but this can be accomplished with the on-line excellence of SEM for X, Y metrology. Furthermore, electron and ion beam sensitive samples can be imaged and characterized by AFM at high resolution.

  8. Proton beam dosimetry for radiosurgery: implementation of the ICRU Report 59 at the Harvard Cyclotron Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Newhauser, Wayne D. [Massachusetts General Hospital, Northeast Proton Therapy Center, Department of Radiation Oncology, Boston, MA (United States)]. E-mail: wnewhauser@mdanderson.org; Myers, Karla D.; Rosenthal, Stanley J.; Smith, Alfred R. [Massachusetts General Hospital, Northeast Proton Therapy Center, Department of Radiation Oncology, Boston, MA (United States)

    2002-04-21

    Recent proton dosimetry intercomparisons have demonstrated that the adoption of a common protocol, e.g. ICRU Report 59, can lead to improved consistency in absorbed dose determinations. We compared absorbed dose values, measured in the 160 MeV proton radiosurgery beamline at the Harvard Cyclotron Laboratory, based on ionization chamber methods with those from a Faraday cup technique. The Faraday cup method is based on a proton fluence determination that allows the estimation of absorbed dose with the CEMA approximation, under which the dose is equal to the fluence times the mean mass stopping power. The ionization chamber technique employs an air-kerma calibration coefficient for {sup 60}Co radiation and a calculated correction in order to take into account the differences in response to {sup 60}Co and proton beam radiations. The absorbed dose to water, based on a diode measurement calibrated with a Faraday cup technique, is approximately 2% higher than was obtained from an ionization chamber measurement. At the Bragg peak depth, the techniques agree to within their respective uncertainties, which are both approximately 4% (1 standard deviation). The ionization chamber technique exhibited superior reproducibility and was adopted in our standard clinical practice for radiosurgery. (author)

  9. Inclined slot-excited annular electron cyclotron resonance plasma source for hyperthermal neutral beam generation.

    Science.gov (United States)

    You, H-J; Kim, D-W; Koo, M; Jang, S-O; Jung, Y-H; Hong, S-H; Lee, B-J

    2011-01-01

    An inclined slot-excited antenna (ISLAN) electron cyclotron resonance (ECR) plasma source is newly designed and constructed for higher flux hyperthermal neutral beam (HNB) generation. The developed ISLAN source is modified from vertical slot-excited antenna (VSLAN) source in two aspects: one is the use of inclined slots instead of vertical slots, and the other is a cusp magnetic field configuration rather than a toroidal configuration. Such modifications allow us to have more uniform arrangement of slots and magnets, then enabling plasma generation more uniform and thinner. Moreover, ECR plasma allows higher ionization rate, enabling plasma density higher even in submillitorr pressures, therefore decreasing the collision rate and∕or the reionization rate of the reflected atoms while passing through the plasma, and eventually getting higher flux of HNBs. In this paper, we report the design features and the plasma characteristics of the ISLAN source by doing plasma measurements and electromagnetic simulations. It was found that ISLAN source can be a high potential source for larger flux HNB generation; the source was found to give higher plasma densities and better uniformities than inductively coupled plasma source, particularly in low pressure ranges. Also, it is important that using ISLAN gives easier matching and better stability, i.e., ISLAN shows similar field patterns and good plasma symmetries irrespective of the variations of the mean diameter of the ring resonator and∕or the presence of a limiter or a reflector, and the operating pressures.

  10. submitter Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    CERN Document Server

    Thomae, R; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V

    2016-01-01

    ABSTRACT At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  11. Production of intense highly charged ion beams by IMP 14.5 GHz electron cyclotron resonance ion source

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new 14.5 GHz Electron Cyclotron Resonance (ECR) ion source has been constructed over the last two years. The source was designed and tested by making use of the latest results from ECR ion source development, such as high mirror magnetic field, large plasma volume, and biased probe. 140μA of O7+, 185μA of Ar11+ and 50 μA of Xe26+ could be produced with a RF power of 800 W. The intense beams of highly charged metallic ions are produced by means of the method of a metal evaporation oven and volatile compound through axial access. The test results are 130μA of Ca11+, 70μA of Ca12+ and 65μA of Fe10+. The ion source has been put into operation for the cyclotron at the Institute of Modern Physics (IMP).

  12. Using the Orbit Tracking Code Z3CYCLONE to Predict the Beam Produced by a Cold Cathode PIG Ion Source for Cyclotrons under DC Extraction

    CERN Document Server

    Forringer, Edward

    2005-01-01

    Experimental measurements of the emittance and luminosity of beams produced by a cold-cathode Phillips Ionization Guage (PIG) ion source for cyclotrons under dc extraction are reviewed. (The source being studied is of the same style as ones that will be used in a series of 250 MeV proton cyclotrons being constructed for cancer therapy by ACCEL Inst, Gmbh, of Bergisch Gladbach, Germany.) The concepts of 'plasma boundary' and 'plasma temperature' are presented as a useful set of parameters for describing the initial conditions used in computational orbit tracking. Experimental results for r-pr and z-pz emittance are compared to predictions from the MSU orbit tracking code Z3CYCLONE with results indicating that the code is able to predict the beam produced by these ion sources with adequate accuracy such that construction of actual cyclotrons can proceed with reasonably prudent confidence that the cyclotron will perform as predicted.

  13. Enhancement of Ar sup 8 sup + ion beam intensity from RIKEN 18 GHz electron cyclotron resonance ion source by optimizing the magnetic field configuration

    CERN Document Server

    Higurashi, Y; Kidera, M; Kase, M; Yano, Y; Aihara, T

    2003-01-01

    We successfully produced a 1.55 emA Ar sup 8 sup + ion beam using the RIKEN 18 GHz electron cyclotron resonance ion source at a microwave power of 700 W. To produce such an intense beam, we optimized the minimum magnetic field of mirror magnetic field and plasma electrode position. (author)

  14. Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions

    CERN Document Server

    Kasarinov, N Y; Kalagin, I V; Kazacha, V I

    2002-01-01

    The gradient method for measuring the transversal emittance of a high current ion beam in the injection channel of the cyclotron DC-72 is considered. The standard scanner is proposed for measuring the transversal dimensions of the beam. The formulae for determination of the mean square beam dimensions by current signals from the scanner needle are adduced. The method of the emittance recovery for axial-symmetric ion beam is set for the case when the space charge effect is essential. The algorithm for tuning of the quadrupole lenses in the injection channel of the cyclotron DC-72 for obtaining the axial-symmetric ion beam is proposed. The evaluations of the expected accuracy of the proposed method for the emittance recovery have been carried out.

  15. The Influence of Neutral Beam Injection on the Heating and Current Drive with Electron Cyclotron Wave on EAST

    Science.gov (United States)

    Chang, Pengxiang; Wu, Bin; Wang, Jinfang; Li, Yingying; Wang, Xiaoguang; Xu, Handong; Wang, Xiaojie; Liu, Yong; Zhao, Hailin; Hao, Baolong; Yang, Zhen; Zheng, Ting; Hu, Chundong

    2016-11-01

    Both neutral beam injection (NBI) and electron cyclotron resonance heating (ECRH) have been applied on the Experimental Advanced Superconducting Tokamak (EAST) in the 2015 campaign. In order to achieve more effective heating and current drive, the effects of NBI on the heating and current drive with electron cyclotron wave (ECW) are analyzed utilizing the code TORAY and experimental data in the shot #54411 and #54417. According to the experimental and simulated results, for the heating with ECW, NBI can improve the heating efficiency and move the power deposition place towards the inside of the plasma. On the other hand, for the electron cyclotron current drive (ECCD), NBI can also improve the efficiency of ECCD and move the place of ECCD inward. These results will be valuable for the center heating, the achievement of fully non-inductive current drive operation and the suppression of magnetohydrodynamic (MHD) instabilities with ECW on EAST or ITER with many auxiliary heating methods. supported by the National Magnetic Confinement Fusion Science Program of China (Nos. 2013GB101001 and 2014DFG61950) and National Natural Science Foundation of China (Nos. 11405212 and 11175211)

  16. Upgrade of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN.

    Science.gov (United States)

    Toivanen, V; Bellodi, G; Dimov, V; Küchler, D; Lombardi, A M; Maintrot, M

    2016-02-01

    Linac3 is the first accelerator in the heavy ion injector chain of the Large Hadron Collider (LHC), providing multiply charged heavy ion beams for the CERN experimental program. The ion beams are produced with GTS-LHC, a 14.5 GHz electron cyclotron resonance ion source, operated in afterglow mode. Improvement of the GTS-LHC beam formation and beam transport along Linac3 is part of the upgrade program of the injector chain in preparation for the future high luminosity LHC. A mismatch between the ion beam properties in the ion source extraction region and the acceptance of the following Low Energy Beam Transport (LEBT) section has been identified as one of the factors limiting the Linac3 performance. The installation of a new focusing element, an einzel lens, into the GTS-LHC extraction region is foreseen as a part of the Linac3 upgrade, as well as a redesign of the first section of the LEBT. Details of the upgrade and results of a beam dynamics study of the extraction region and LEBT modifications will be presented.

  17. Upgrade of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

    Science.gov (United States)

    Toivanen, V.; Bellodi, G.; Dimov, V.; Küchler, D.; Lombardi, A. M.; Maintrot, M.

    2016-02-01

    Linac3 is the first accelerator in the heavy ion injector chain of the Large Hadron Collider (LHC), providing multiply charged heavy ion beams for the CERN experimental program. The ion beams are produced with GTS-LHC, a 14.5 GHz electron cyclotron resonance ion source, operated in afterglow mode. Improvement of the GTS-LHC beam formation and beam transport along Linac3 is part of the upgrade program of the injector chain in preparation for the future high luminosity LHC. A mismatch between the ion beam properties in the ion source extraction region and the acceptance of the following Low Energy Beam Transport (LEBT) section has been identified as one of the factors limiting the Linac3 performance. The installation of a new focusing element, an einzel lens, into the GTS-LHC extraction region is foreseen as a part of the Linac3 upgrade, as well as a redesign of the first section of the LEBT. Details of the upgrade and results of a beam dynamics study of the extraction region and LEBT modifications will be presented.

  18. Beam Loss by Lorentz Stripping in a 100 MeV Compact H~- Cyclotron

    Institute of Scientific and Technical Information of China (English)

    Larry; Root

    2002-01-01

    The success of TRIUMF’s ISAC facility demonstrates that a 500 MeV 100 μ A H cyclotron is agood choice for the driver stage of an ISOL type RIB facility. As a result, China Institute of AtomicEnergy is proposing the construction of a 75~100 MeV 200~500μA H~- cyclotron as an upgrade to theBeijing Tandem Laboratory. This would be a multiple user facility, which would include a RIB target

  19. Cyclotron Institute Upgrade Project

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Henry [Texas A& M University; Yennello, Sherry [Texas A& M University; Tribble, Robert [Texas A& M University

    2014-08-26

    The Cyclotron Institute at Texas A&M University has upgraded its accelerator facilities to extend research capabilities with both stable and radioactive beams. The upgrade is divided into three major tasks: (1) re-commission the K-150 (88”) cyclotron, couple it to existing beam lines to provide intense stable beams into the K-500 experimental areas and use it as a driver to produce radioactive beams; (2) develop light ion and heavy ion guides for stopping radioactive ions created with the K-150 beams; and (3) transport 1+ ions from the ion guides into a charge-breeding electron-cyclotron-resonance ion source (CB-ECR) to produce highly-charged radioactive ions for acceleration in the K-500 cyclotron. When completed, the upgraded facility will provide high-quality re-accelerated secondary beams in a unique energy range in the world.

  20. Monte Carlo simulation to evaluate the contamination in an energy modulated carbon ion beam for hadron therapy delivered by cyclotron.

    Science.gov (United States)

    Morone, M Cristina; Calabretta, Luciano; Cuttone, Giacomo; Fiorini, Francesca

    2008-11-07

    Protons and carbon ion beams for hadron therapy can be delivered by cyclotrons with a fixed energy. In order to treat patients, an energy degrader along the beam line will be used to match the particle range with the target depth. Fragmentation reactions of carbon ions inside the degrader material could introduce a small amount of unwanted contaminants to the beam, giving additional dose to the patient out of the target volume. A simulation study using the FLUKA Monte Carlo code has been carried out by considering three different materials as the degrader. Two situations have been studied: a realistic one, lowering the carbon beam energy from 300 MeV/n to 220 MeV/n, corresponding to a range of 10 cm in water, and the worst possible case, lowering the carbon energy to 50 MeV/n, corresponding to the millimeter range. The main component of the contaminant is represented by alpha particles and protons, with a typical momentum after the degrader greater than that of the primary beam, and can be eliminated by the action of a momentum analyzing system and slits, and by a second thin absorber. The residual component of fragments reaching the patient is negligible with respect to the fragment quantity generated by the primary beam inside the patient before arriving at the end of the target volume.

  1. Effect of imperfections of the radial component of a magnetic field on beam dynamics in medical cyclotron C235-V3

    Science.gov (United States)

    Karamysheva, G. A.; Kostromin, S. A.; Morozov, N. A.; Samsonov, E. V.; Syresin, E. M.

    2014-11-01

    This paper presents numerical simulations and experimental results related to the effect of imperfections of the radial component of a magnetic field on the beam dynamics in the medical cyclotron C235-V3 of the Dimitrovgrad Proton Therapy Center. These imperfections in the region of the minimal axial betatron frequency lead to a transformation of coherent motion of the center of gravity of the beam to the incoherent motion of separate particles. The radial component increases the axial size of the beam by a factor of 2 at a radius of 20 cm, which produces additional losses of protons. To reduce undesirable actions of the radial component on the axial motion, the magnetic system in the central region has been optimized using two procedures: the positioning of shim correctors on sectors and selecting a special asymmetric arrangement of the upper and lower central plugs. This led to a twofold reduction in the axial size of the beam and a decrease in proton losses. Eventually, the beam transmission in C235-V3 has been increased to 72% without a limiting aperture diaphragm, which is commonly used in cyclotrons of this type. This makes it possible to reduce the irradiation dose of machine elements and increase the beam current at a deflector entrance of the cyclotron C235-V3 by a factor of 1.5 when compared to a serial C235 cyclotron.

  2. Medical cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A P

    1976-01-01

    Cyclotrons as tools for therapy and for the production of radionuclides for use in nuclear medicine have been extensively reviewed in the literature. The current world status with respect to cyclotrons used primarily for research, development and application in nuclear medicine is reviewed here in the context of geographical distribution and type of use, presently available commercial types, machine characteristics and trends. Aspects of design requirements from a user perspective such as machine, beam and target characteristics are covered. Some special problems concerning many factors which can lead to effective production of the desired radionuclide or product are considered in light of machine characteristics. Consideration is also given to future directions for accelerators in nuclear medicine.

  3. Charge breeding results and future prospects with electron cyclotron resonance ion source and electron beam ion source (invited).

    Science.gov (United States)

    Vondrasek, R; Levand, A; Pardo, R; Savard, G; Scott, R

    2012-02-01

    The Californium Rare Ion Breeder Upgrade (CARIBU) of the Argonne National Laboratory ATLAS facility will provide low-energy and reaccelerated neutron-rich radioactive beams for the nuclear physics program. A 70 mCi (252)Cf source produces fission fragments which are thermalized and collected by a helium gas catcher into a low-energy particle beam with a charge of 1+ or 2+. An electron cyclotron resonance (ECR) ion source functions as a charge breeder in order to raise the ion charge sufficiently for acceleration in the ATLAS linac. The final CARIBU configuration will utilize a 1 Ci (252)Cf source to produce radioactive beams with intensities up to 10(6) ions∕s for use in the ATLAS facility. The ECR charge breeder has been tested with stable beam injection and has achieved charge breeding efficiencies of 3.6% for (23)Na(8+), 15.6% for (84)Kr(17+), and 13.7% for (85)Rb(19+) with typical breeding times of 10 ms∕charge state. For the first radioactive beams, a charge breeding efficiency of 11.7% has been achieved for (143)Cs(27+) and 14.7% for (143)Ba(27+). The project has been commissioned with a radioactive beam of (143)Ba(27+) accelerated to 6.1 MeV∕u. In order to take advantage of its lower residual contamination, an EBIS charge breeder will replace the ECR charge breeder in the next two years. The advantages and disadvantages of the two techniques are compared taking into account the requirements of the next generation radioactive beam facilities.

  4. Generation of high charge state metal ion beams by electron cyclotron resonance heating of vacuum arc plasma in cusp trap.

    Science.gov (United States)

    Nikolaev, A G; Savkin, K P; Oks, E M; Vizir, A V; Yushkov, G Yu; Vodopyanov, A V; Izotov, I V; Mansfeld, D A

    2012-02-01

    A method for generating high charge state heavy metal ion beams based on high power microwave heating of vacuum arc plasma confined in a magnetic trap under electron cyclotron resonance conditions has been developed. A feature of the work described here is the use of a cusp magnetic field with inherent "minimum-B" structure as the confinement geometry, as opposed to a simple mirror device as we have reported on previously. The cusp configuration has been successfully used for microwave heating of gas discharge plasma and extraction from the plasma of highly charged, high current, gaseous ion beams. Now we use the trap for heavy metal ion beam generation. Two different approaches were used for injecting the vacuum arc metal plasma into the trap--axial injection from a miniature arc source located on-axis near the microwave window, and radial injection from sources mounted radially at the midplane of the trap. Here, we describe preliminary results of heating vacuum arc plasma in a cusp magnetic trap by pulsed (400 μs) high power (up to 100 kW) microwave radiation at 37.5 GHz for the generation of highly charged heavy metal ion beams.

  5. Studies of extraction and transport system for highly charged ion beam of 18 GHz superconducting electron cyclotron resonance ion source at Research Center for Nuclear Physics.

    Science.gov (United States)

    Yorita, T; Hatanaka, K; Fukuda, M; Ueda, H; Yasuda, Y; Morinobu, S; Tamii, A; Kamakura, K

    2014-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source is installed to increase beam currents and to extend the variety of ions especially for highly charged heavy ions which can be accelerated by cyclotrons of Research Center for Nuclear Physics (RCNP), Osaka University. The beam production developments of several ions from B to Xe have been already done [T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 79, 02A311 (2008) and T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 81, 02A332 (2010)] and the further studies for those beam extraction and its transport have been done in order to increase the beam current more. The plasma electrode, extraction electrode, and einzel lens are modified. Especially extraction electrode can be applied minus voltage for the beam extraction and it works well to improve the extracted beam current. The extraction voltage dependences of transmission and emittance also have been studied for beam current improvement which is injected into azimuthally varying field cyclotron at RCNP.

  6. Studies of extraction and transport system for highly charged ion beam of 18 GHz superconducting electron cyclotron resonance ion source at Research Center for Nuclear Physics

    Science.gov (United States)

    Yorita, T.; Hatanaka, K.; Fukuda, M.; Ueda, H.; Yasuda, Y.; Morinobu, S.; Tamii, A.; Kamakura, K.

    2014-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source is installed to increase beam currents and to extend the variety of ions especially for highly charged heavy ions which can be accelerated by cyclotrons of Research Center for Nuclear Physics (RCNP), Osaka University. The beam production developments of several ions from B to Xe have been already done [T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 79, 02A311 (2008) and T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 81, 02A332 (2010)] and the further studies for those beam extraction and its transport have been done in order to increase the beam current more. The plasma electrode, extraction electrode, and einzel lens are modified. Especially extraction electrode can be applied minus voltage for the beam extraction and it works well to improve the extracted beam current. The extraction voltage dependences of transmission and emittance also have been studied for beam current improvement which is injected into azimuthally varying field cyclotron at RCNP.

  7. Studies of extraction and transport system for highly charged ion beam of 18 GHz superconducting electron cyclotron resonance ion source at Research Center for Nuclear Physics

    Energy Technology Data Exchange (ETDEWEB)

    Yorita, T., E-mail: yorita@rcnp.osaka-u.ac.jp; Hatanaka, K.; Fukuda, M.; Ueda, H.; Yasuda, Y.; Morinobu, S.; Tamii, A.; Kamakura, K. [Research Center for Nuclear Physics (RCNP), Osaka University, Osaka 567-0047 (Japan)

    2014-02-15

    An 18 GHz superconducting electron cyclotron resonance ion source is installed to increase beam currents and to extend the variety of ions especially for highly charged heavy ions which can be accelerated by cyclotrons of Research Center for Nuclear Physics (RCNP), Osaka University. The beam production developments of several ions from B to Xe have been already done [T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 79, 02A311 (2008) and T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 81, 02A332 (2010)] and the further studies for those beam extraction and its transport have been done in order to increase the beam current more. The plasma electrode, extraction electrode, and einzel lens are modified. Especially extraction electrode can be applied minus voltage for the beam extraction and it works well to improve the extracted beam current. The extraction voltage dependences of transmission and emittance also have been studied for beam current improvement which is injected into azimuthally varying field cyclotron at RCNP.

  8. Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL.

    Science.gov (United States)

    Zhao, H W; Sun, L T; Zhang, X Z; Guo, X H; Cao, Y; Lu, W; Zhang, Z M; Yuan, P; Song, M T; Zhao, H Y; Jin, T; Shang, Y; Zhan, W L; Wei, B W; Xie, D Z

    2008-02-01

    There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e microA of O(7+), 505 e microA of Xe(20+), 306 e microA of Xe(27+), and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

  9. Optimization of a charge-state analyzer for electron cyclotron resonance ion source beams

    NARCIS (Netherlands)

    Saminathan, S.; Beijers, J. P. M.; Kremers, H. R.; Mironov, V.; Mulder, J.; Brandenburg, S.

    2012-01-01

    A detailed experimental and simulation study of the extraction of a 24 keV He+ beam from an ECR ion source and the subsequent beam transport through an analyzing magnet is presented. We find that such a slow ion beam is very sensitive to space-charge forces, but also that the neutralization of the b

  10. Effect of upflowing field-aligned electron beams on the electron cyclotron waves in the auroral magnetosphere

    Indian Academy of Sciences (India)

    Sushil Kumar; S K Singh; A K Gwal

    2007-04-01

    The role of low density upflowing field-aligned electron beams (FEBs) on the growth rate of the electron cyclotron waves at the frequencies r < ­e, propagating downward in the direction of the Earth's magnetic field, has been analysed in the auroral region at e/e < 1 where e is the plasma frequency and ­e is the gyrofrequency. The FEBs with low to high energy (b) but with low temperature (∥b) have no effect on these waves. The FEBs with b < 1 keV and ∥b (> 1.5 keV) have been found to have significant effect on the growth rate. Analysis has revealed that it is mainly the ∥b which inhibits the growth rate (magnitude) and the range of frequency (bandwidth) of the instability mainly in the higher frequency spectrum. The inhibition in the growth rate and bandwidth increases with increase in ∥b. The FEBs with less b (giving drift velocity) reduce growth rate more than the beams with larger b. The inhibition of growth rate increases with the increase in the ratio e/e indicating that the beams are more effective at higher altitudes.

  11. A test-bench for isotope separator on-line of Beijing radioactive ion-beam facility

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Bing, E-mail: tangb364@126.com; Ma, Ruigang; Huang, Qinghua; Chen, Lihua; Ma, Yingjun; Cui, Baoqun; Jiang, Weisheng

    2013-12-15

    Highlights: • The modular design makes the maintenance of target station easily. • The diagnosis for low intensity beam is solved. • A positive surface ion source has been developed. -- Abstract: A test-bench for isotope separator on-line of Beijing radioactive ion-beam facility (BRISOL) has been built in China Institute of Atomic Energy (CIAE). The test-bench consists of target station, charge exchange cell, mass separator, quadrupole, hexapole, multipole and beam diagnostic system. It is nearly the same configuration as the first stage of BRISOL and all these components will be used on the BRISOL. A series of experiments have been carried out on this test-bench, and the primary results showed that all the components worked well. A Li{sup +} beam has been generated from the positive surface-ionization source and its emittance and the transmission of the beam line have been measured. The design, construction and experimental results of this test-bench have been presented.

  12. Matrix:. AN Innovative Pixel Ionization Chamber for On-Line Beam Monitoring in Hadrontherapy

    Science.gov (United States)

    Braccini, S.; Pitta', G.; Donetti, M.; Cirio, R.; La Rosa, A.; Garella, M. A.; Giordanengo, S.; Marchetto, F.; Peroni, C.

    2006-04-01

    The control of intensity, position and shape of clinical beams are key issues in the treatment of tumours using hadron beams, especially in the case of active dose distribution systems. For this purpose an innovative pixel ionization chamber, named MATRIX, has been designed, constructed and tested. The chamber is conceived to be located very near the patient to precisely monitor the beam parameters used to verify the treatment planning specifications. MATRIX operates in air and is characterized by a 21 × 21 cm2 sensitive area subdivided in 1024 pixels of 6.5 × 6.5 mm2. To minimize the amount of material crossed by the beam, the anode is made of a 50 μm kapton foil, with a deposit of 17 μm copper on each side. A very sensitive electronics is used for the readout, based on a dedicated chip. In this paper the construction of the chamber and the very positive results of the first beam tests are described.

  13. Harvesting (67)Cu from the Collection of a Secondary Beam Cocktail at the National Superconducting Cyclotron Laboratory.

    Science.gov (United States)

    Mastren, Tara; Pen, Aranh; Loveless, Shaun; Marquez, Bernadette V; Bollinger, Elizabeth; Marois, Boone; Hubley, Nicholas; Brown, Kyle; Morrissey, David J; Peaslee, Graham F; Lapi, Suzanne E

    2015-10-20

    Isotope harvesting is a promising new method to obtain isotopes for which there is no reliable continuous supply at present. To determine the possibility of obtaining radiochemically pure radioisotopes from an aqueous beam dump at a heavy-ion fragmentation facility, preliminary experiments were performed to chemically extract a copper isotope from a large mixture of projectile fragmentation products in an aqueous medium. In this work a 93 MeV/u secondary beam cocktail was collected in an aqueous beam stop at the National Superconducting Cyclotron Laboratory (NSCL) located on the Michigan State University (MSU) campus. The beam cocktail consisted of ∼2.9% (67)Cu in a large mixture of co-produced isotopes ranging in atomic number from ∼19 to 34. The chemical extraction of (67)Cu was achieved via a two-step process: primary extraction using a divalent metal chelation disk followed by anion-exchange chromatography. A significant fraction (74 ± 4%) of the (67)Cu collected in the aqueous beam stop was recovered with >99% radiochemical purity. To illustrate the utility of this product, the purified (67)Cu material was then used to radiolabel an anti-EGFR antibody, Panitumumab, and injected into mice bearing colon cancer xenografts. The tumor uptake at 5 days postinjection was found to be 12.5 ± 0.7% which was in very good agreement with previously reported studies with this radiolabeled antibody. The present results demonstrate that harvesting isotopes from a heavy-ion fragmentation facility could be a promising new method for obtaining high-quality isotopes that are not currently available by traditional methods.

  14. Effect of electron cyclotron resonance ion source frequency tuning on ion beam intensity and quality at Department of Physics, University of Jyvaeskylae

    Energy Technology Data Exchange (ETDEWEB)

    Toivanen, V.; Koivisto, H.; Steczkiewicz, O.; Tarvainen, O.; Ropponen, T. [Department of Physics, University of Jyvaeskylae (JYFL) (Finland); Celona, L.; Gammino, S.; Mascali, D.; Ciavola, G. [Instituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, 95123 Catania (Italy)

    2010-02-15

    Ion beam intensity and quality have a crucial effect on the operation efficiency of the accelerator facilities. This paper presents the investigations on the ion beam intensity and quality after the mass separation performed with the Department of Physics, University of Jyvaeskylae 14 GHz electron cyclotron resonance ion source by sweeping the microwave in the 14.05-14.13 GHz range. In many cases a clear variation in the ion beam intensity and quality as a function of the frequency was observed. The effect of frequency tuning increased with the charge state. In addition, clear changes in the beam structure seen with the beam viewer were observed. The results confirmed that frequency tuning can have a remarkable effect on ion beam intensity and quality especially in the case of highly charged ion beams. The examples presented here represent the typical charge state behavior observed during the measurements.

  15. Comparison of cyclotron and linacs for high-intensity-beam applications

    Energy Technology Data Exchange (ETDEWEB)

    Bhatia, T.S.; Jason, A.; Mottershead, C.T. [Los Alamos National Lab., NM (United States); Cooper, R. [Amparo Corp., NM (United States)

    1998-11-01

    This is the final report of a two-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The goals of this project were three-fold: (1) to understand the current level of cyclotron design expertise especially in the areas of space-charge modeling and simulation codes, (2) to develop a better understanding of the capabilities and limitations of circular machines, especially in the area of current limits, and (3) to stay abreast of the developments at other institutions in the area of high-current circular machines. These goals were partially met especially in the area of code development for the application of linac codes to motion of ions in a circular orbit. The authors were also able to continue their interactions with the other institutions working in this area.

  16. Collective Thomson scattering of a high power electron cyclotron resonance heating beam in LHD

    DEFF Research Database (Denmark)

    Kubo, S.; Nishiura, M.; Tanaka, K.

    2010-01-01

    Collective Thomson scattering (CTS) system has been constructed at LHD making use of the high power ECRH system in LHD. The necessary features for CTS, high power probing beams and receiving beams, both with well defined Gaussian profile and with the fine controllability, are endowed in the ECRH...

  17. SHyPIE: a new source for on-line production of multicharged radioactive condensable ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Lecesne, N.; Foury, P.; Gaubert, G.; Huguet, Y.; Jardin, P.; Leroy, R.; Lewitowicz, M.; Marry, C.; Maunoury, L.; Pacquet, J.Y.; Robert, E.; Saint-Laurent, M.G.; Seron, D.; Sortais, P.; Villari, A.C.C. [Grand Accelerateur National d' Ions Lourds (GANIL), 14 - Caen (France); Angelique, J.C.; Orr, N.A. [Laboratoire de Physique Corpusculaire (CNRS/IN2P3), ISMRA, 14 - Caen (France); Blank, B. [CENBG, Centre d' Etudes Nucleaires de Bordeaux Gradignan, 33 (France); Clapier, F.; Ducourtieux, M.; Kandri-Rody, S.; Obert, J.; Pauwels, N.; Proust, J.; Putaux, J.C. [Institut de Physique Nucleaire, (IN2P3/CNRS) 91 - Orsay (France); Lepine, A. [IFUSP, C.P., Sao Paulo (Brazil)

    1999-07-01

    In order to define the future intensity and reliability of the on line radioactive beams for the SPIRAL project, an intense activity of research and development is being done around the target and the ion source problems. The main instrument for this purpose is the isotopic separator SIRa (Separateur d'Ions Radioactifs) installed in the D2 experimental cave at GANIL. One of the research axis is the production of multicharged radioactive condensable ions. In this aim, we have built a new compact ECR ion source, SHyPIE (Source Hybride pour la Production d'Ions Exotiques), whose original magnetic configuration is under patent since 1997. This new magnetic structure allows to place an internal production target very close to the plasma, while avoiding radiation damages of the sensitive permanent magnets. A series of on line experiments have been done, using SHyPIE with several internal target systems, and around thirty species of condensable and noble gases radioactive multicharged ion beams have been produced. The behaviour of the plasma in a close geometry with the production target has been studied. (authors)

  18. Photoconducting ultraviolet detectors based on GaN films grown by electron cyclotron resonance molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Misra, M.; Shah, K.S. [Radiation Monitoring Devices, Inc., Watertown, MA (United States); Moustakas, T.D.; Vaudo, R.P.; Singh, R. [Boston Univ., MA (United States). Molecular Beam Epitaxy Lab.

    1995-08-01

    We report for the first time, fabrication of photoconducting UV detectors made from GaN films grown by molecular beam epitaxy. Semi-instilating GaN films were grown by the method of electron cyclotron resonance microwave plasma-assisted molecular beam epitaxy (ECR-MBE). Photoconductive devices with interdigitated electrodes were fabricated and their photoconducting properties were investigated. In this paper we report on the performance of the detectors in terms of UV responsivity, gain-quantum efficiency product, spectral response and response time. We have measured responsivity of 125A/W and gain-quantum efficiency product of 600 at 254nm and 25V. The response time was measured to be on the order of 20ns for our detectors, corresponding to a bandwidth of 25Mhz. The spectral response showed a sharp long-wavelength cutoff at 365nm, and remained constant in the 200nm to 365nm range. The response of the detectors to low-energy x-rays was measured and found to be linear for x-rays with energies ranging from 60kVp to 90kVp.

  19. Profiles of ion beams and plasma parameters on a multi-frequencies microwaves large bore electron cyclotron resonance ion source with permanent magnets.

    Science.gov (United States)

    Kato, Yushi; Sakamoto, Naoki; Kiriyama, Ryutaro; Takenaka, Tomoya; Kurisu, Yosuke; Nozaki, Dai; Sato, Fuminobu; Iida, Toshiyuki

    2012-02-01

    In order to contribute to various applications of plasma and beams based on an electron cyclotron resonance, a new concept on magnetic field with all magnets on plasma production and confinement has been proposed with enhanced efficiency for broad and dense ion beam. The magnetic field configuration consists of a pair of comb-shaped magnet surrounding plasma chamber cylindrically. Resonance zones corresponding for 2.45 GHz and 11-13 GHz frequencies are positioned at spatially different positions. We launch simultaneously multiplex frequencies microwaves operated individually, try to control profiles of the plasma parameters and the extracted ion beams, and to measure them in detail.

  20. First results of the INSIDE in-beam PET scanner for the on-line monitoring of particle therapy treatments

    Science.gov (United States)

    Piliero, M. A.; Belcari, N.; Bisogni, M. G.; Camarlinghi, N.; Cerello, P.; Coli, S.; Del Guerra, A.; Ferrero, V.; Fiorina, E.; Giraudo, G.; Kostara, E.; Morrocchi, M.; Pennazio, F.; Peroni, C.; Pirrone, G.; Rivetti, A.; Rolo, M. D.; Rosso, V.; Sportelli, G.; Wheadon, R.

    2016-12-01

    Quality assessment of particle therapy treatments by means of PET systems has been carried out since late `90 and it is one of the most promising in-vivo non invasive monitoring techniques employed clinically. It can be performed with a diagnostic PET scanners installed outside the treatment room (off-line monitoring) or inside the treatment room (in-room monitoring). However the most efficient way is by integrating a PET scanner with the treatment delivery system (on-line monitoring) so that the biological wash out and the patient repositioning errors are minimized. In this work we present the performance of the in-beam PET scanner developed within the INSIDE project. The INSIDE PET scanner is made of two planar heads, 10 cm wide (transaxially) and 25 cm long (axially), composed of pixellated LFS crystals coupled to Hamamatsu MPPCs. Custom designed Front-End Electronics (FE) and Data AcQuisition (DAQ) systems allow an on-line reconstruction of PET images from separated in-spill and inter-spill data sets. The INSIDE PET scanner has been recently delivered at the CNAO (Pavia, Italy) hadrontherapy facility and the first experimental measurements have been carried out. Homogeneous PMMA phantoms and PMMA phantoms with small air and bone inserts were irradiated with monoenergetic clinical proton beams. The activity range was evaluated at various benchmark positions within the field of view to assess the homogeneity of response of the PET system. Repeated irradiations of PMMA phantoms with clinical spread out Bragg peak proton beams were performed to evaluate the reproducibility of the PET signal. The results found in this work show that the response of the INSIDE PET scanner is independent of the position within the radiation field. Results also show the capability of the INSIDE PET scanner to distinguish variations of the activity range due to small tissue inhomogeneities. Finally, the reproducibility of the activity range measurement was within 1 mm.

  1. Development of a compact thermal lithium atom beam source for measurements of electron velocity distribution function anisotropy in electron cyclotron resonance plasmas.

    Science.gov (United States)

    Nishioka, T; Shikama, T; Nagamizo, S; Fujii, K; Zushi, H; Uchida, M; Iwamae, A; Tanaka, H; Maekawa, T; Hasuo, M

    2013-07-01

    The anisotropy of the electron velocity distribution function (EVDF) in plasmas can be deduced from the polarization of emissions induced by anisotropic electron-impact excitation. In this paper, we develop a compact thermal lithium atom beam source for spatially resolved measurements of the EVDF anisotropy in electron cyclotron resonance (ECR) plasmas. The beam system is designed such that the ejected beam has a slab shape, and the beam direction is variable. The divergence and flux of the beam are evaluated by experiments and calculations. The developed beam system is installed in an ECR plasma device with a cusp magnetic field, and the LiI 2s-2p emission (670.8 nm) is observed in low-pressure helium plasma. The two-dimensional distributions of the degree and direction of the polarization in the LiI emission are measured by a polarization imaging system. The evaluated polarization distribution suggests the spatial variation of the EVDF anisotropy.

  2. Comparison of short-lived medical isotopes activation by laser thin target induced protons and conventional cyclotron proton beams

    Science.gov (United States)

    Murray, Joseph; Dudnikova, Galina; Liu, Tung-Chang; Papadopoulos, Dennis; Sagdeev, Roald; Su, J. J.; UMD MicroPET Team

    2014-10-01

    Production diagnostic or therapeutic nuclear medicines are either by nuclear reactors or by ion accelerators. In general, diagnostic nuclear radioisotopes have a very short half-life varying from tens of minutes for PET tracers and few hours for SPECT tracers. Thus supplies of PET and SPECT radiotracers are limited by regional production facilities. For example 18F-fluorodeoxyglucose (FDG) is the most desired tracer for positron emission tomography because its 110 minutes half-life is sufficient long for transport from production facilities to nearby users. From nuclear activation to completing image taking must be done within 4 hours. Decentralized production of diagnostic radioisotopes will be idea to make high specific activity radiotracers available to researches and clinicians. 11 C, 13 N, 15 O and 18 F can be produced in the energy range from 10-20 MeV by protons. Protons of energies up to tens of MeV generated by intense laser interacting with hydrogen containing targets have been demonstrated by many groups in the past decade. We use 2D PIC code for proton acceleration, Geant4 Monte Carlo code for nuclei activation to compare the yields and specific activities of short-lived isotopes produced by cyclotron proton beams and laser driven protons.

  3. G2DEM: a parallel two-dimensional electromagnetic PIC code for the study of electron-cyclotron instabilities of relativistic electron beams in cylindrical cavities

    Energy Technology Data Exchange (ETDEWEB)

    Jost, G.; Tran, T.M.; Appert, K. [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP); Wuethrich, S. [CRAY Research, PATP/PSE, EPFL, Lausanne (Switzerland)

    1996-12-01

    A two-dimensional PIC code aimed at the investigation of electron-cyclotron beam instabilities in gyrotrons and their effects on the beam quality is presented. The code is based on recently developed techniques for handling charge conservation and open boundaries and uses an electromagnetic field which is decomposed in its transverse magnetic (TM) and electric (TE) components. The code has been implemented on the massively parallel computer CRAY T3D, and on the CRAY Y-MP. (author) figs., tabs., refs.

  4. SU-E-J-92: On-Line Cone Beam CT Based Planning for Emergency and Palliative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Held, M; Morin, O; Pouliot, J [UC San Francisco, San Francisco, CA (United States)

    2014-06-01

    Purpose: To evaluate and develop the feasibility of on-line cone beam CT based planning for emergency and palliative radiotherapy treatments. Methods: Subsequent to phantom studies, a case library of 28 clinical megavoltage cone beam CT (MVCBCT) was built to assess dose-planning accuracies on MVCBCT for all anatomical sites. A simple emergency treatment plan was created on the MVCBCT and copied to its reference CT. The agreement between the dose distributions of each image pair was evaluated by the mean dose difference of the dose volume and the gamma index of the central 2D axial plane. An array of popular urgent and palliative cases was also evaluated for imaging component clearance and field-of-view. Results: The treatment cases were categorized into four groups (head and neck, thorax/spine, pelvis and extremities). Dose distributions for head and neck treatments were predicted accurately in all cases with a gamma index of >95% for 2% and 2 mm criteria. Thoracic spine treatments had a gamma index as low as 60% indicating a need for better uniformity correction and tissue density calibration. Small anatomy changes between CT and MVCBCT could contribute to local errors. Pelvis and sacral spine treatment cases had a gamma index between 90% and 98% for 3%/3 mm criteria. The limited FOV became an issue for large pelvis patients. Imaging clearance was difficult for cases where the tumor was positioned far off midline. Conclusion: The MVCBCT based dose planning and delivery approach is feasible in many treatment cases. Dose distributions for head and neck patients are unrestrictedly predictable. Some FOV restrictions apply to other treatment sites. Lung tissue is most challenging for accurate dose calculations given the current imaging filters and corrections. Additional clinical cases for extremities need to be included in the study to assess the full range of site-specific planning accuracies. This work is supported by Siemens.

  5. Production of neutron deficient rare isotope beams at IGISOL; on-line and off-line studies

    Energy Technology Data Exchange (ETDEWEB)

    Huikari, J. E-mail: jussi.huikari@phys.jyu.fi; Dendooven, P.; Jokinen, A.; Nieminen, A.; Penttilae, H.; Peraejaervi, K.; Popov, A.; Rinta-Antila, S.; Aeystoe, J

    2004-08-01

    This article reports on recent on-line yield measurements employing the light-ion and heavy-ion reaction-based ion guide systems and new results on {alpha}-recoil ion transport properties in ion guides with and without electric fields. In addition, the presently used ion guide designs for fusion evaporation reactions are introduced. The present study investigated different schemes for ion extraction from the gas cell. The addition of an extra ring electrode between the traditional skimmer electrode and the exit hole led to transmission independent of the primary beam intensity as opposed to strong intensity dependence observed earlier with the plain skimmer only. Furthermore, the mass resolving power of the IGISOL mass separator was increased to 1100 as compared to 250 with the skimmer system when using the RF-sextupole for the extraction from the heavy-ion ion guide. As a new method, the possibility to increase the ion guide efficiency by injecting electrons into the stopping volume is introduced. The efficiency of the electron emitter ion guide was a factor of ten higher in off-line conditions. Also, the influence of the buffer gas purity on the ion survival is discussed.

  6. The Eurisol report. A feasibility study for a European isotope-separation-on-line radioactive ion beam facility

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-12-01

    The Eurisol project aims at a preliminary design study of the next-generation European isotope separation on-line (ISOL) radioactive ion beam (RIB) facility. In this document, the scientific case of high-intensity RIBs using the ISOL method is first summarised, more details being given in appendix A. It includes: 1) the study of atomic nuclei under extreme and so-far unexplored conditions of composition (i.e. as a function of the numbers of protons and neutrons, or the so-called isospin), rotational angular velocity (or spin), density and temperature, 2) the investigation of the nucleosynthesis of heavy elements in the Universe, an important part of nuclear astrophysics, 3) a study of the properties of the fundamental interactions which govern the properties of the universe, and in particular of the violation of some of their symmetries, 4) potential applications of RIBs in solid-state physics and in nuclear medicine, for example, where completely new fields could be opened up by the availability of high-intensity RIBs produced by the ISOL method. The proposed Eurisol facility is then presented, with particular emphasis on its main components: the driver accelerator, the target/ion-source assembly, the mass-selection system and post-accelerator, and the required scientific instrumentation. Special details of these components are given in appendices B to E, respectively. The estimates of the costs of the Eurisol, construction and running costs, have been performed in as much details as is presently possible. The total capital cost (installation manpower cost included) of the project is estimated to be of the order of 630 million Euros within 20%. In general, experience has shown that operational costs per annum for large accelerator facilities are about 10% of the capital cost. (A.C.)

  7. Spiral Inflector For Compact Cyclotron

    CERN Document Server

    Karamysheva, G A

    2004-01-01

    Compact cyclotron for explosives detection by nuclear resonance absorption of γ-rays in nitrogen is under development [1] Cyclotron will be equipped with the external ion source. The injection system consists of a double-drift beam bunching system, a spiral inflector, beam diagnostics, focusing and adjustment elements [2]. The spiral inflector for ion bending from axial to median plane is used. Computer model of spiral inflector for the Customs cyclotron is developed. 3D electrostatic field calculations of the designed inflector are performed. Calculated electric field map and magnetic field map of the cyclotron [3] are used for beam dynamic simulations. Numeric simulations are carried out for 500 particles using code for calculation of particle dynamics by integration of differential equations in Cartesian coordinate system written in MATLAB. Direct Coulomb particle-to-particle method is used to take into account space-charge effects.

  8. High current H{sub 2}{sup +} and H{sub 3}{sup +} beam generation by pulsed 2.45 GHz electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yuan; Peng, Shixiang, E-mail: sxpeng@pku.edu.cn; Ren, Haitao; Zhao, Jie; Chen, Jia; Zhang, Tao; Guo, Zhiyu [State Key Laboratory of Nuclear Physics and Technology and Institute of Heavy Ion Physics, Peking University, Beijing 100871 (China); Zhang, Ailin [University of Chinese Academy of Sciences, Beijing 100049 (China); Chen, Jia' er [State Key Laboratory of Nuclear Physics and Technology and Institute of Heavy Ion Physics, Peking University, Beijing 100871 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2014-02-15

    The permanent magnet 2.45 GHz electron cyclotron resonance ion source at Peking University can produce more than 100 mA hydrogen ion beam working at pulsed mode. For the increasing requirements of cluster ions (H{sub 2}{sup +} and H{sub 3}{sup +}) in linac and cyclotron, experimental study was carried out to further understand the hydrogen plasma processes in the ion source for the generation of cluster ions. The constituents of extracted beam have been analyzed varying with the pulsed duration from 0.3 ms to 2.0 ms (repetition frequency 100 Hz) at different operation pressure. The fraction of cluster ions dramatically increased when the pulsed duration was lower than 0.6 ms, and more than 20 mA pure H{sub 3}{sup +} ions with fraction 43.2% and 40 mA H{sub 2}{sup +} ions with fraction 47.7% were obtained when the operation parameters were adequate. The dependence of extracted ion fraction on microwave power was also measured at different pressure as the energy absorbed by plasma will greatly influence electron temperature and electron density then the plasma processes in the ion source. More details will be presented in this paper.

  9. BEST medical radioisotope production cyclotrons

    Science.gov (United States)

    Sabaiduc, Vasile; Milton, Bruce; Suthanthiran, Krishnan; Gelbart, W. Z.; Johnson, Richard R.

    2013-04-01

    Best Cyclotron Systems Inc (BCSI) is currently developing 14 MeV, 25 MeV, 35MeV and 70MeV cyclotrons for radioisotope production and research applications as well as the entire spectrum of targets and nuclear synthesis modules for the production of Positron Emission Tomography (PET), Single Photon Emission Computed Tomography (SPECT) and radiation therapy isotopes. The company is a subsidiary of Best Medical International, renowned in the field of medical instrumentation and radiation therapy. All cyclotrons have external negative hydrogen ion sources, four radial sectors with two dees in opposite valleys, cryogenic vacuum system and simultaneous beam extraction on opposite lines. The beam intensity ranges from 400 μA to 1000 μA, depending on the cyclotron energy and application [1].

  10. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yu Seok; Chai, Jong Seo; Bak, Seong Ki; Park, Chan Won; Jo, Young Ho; Hong, Seong Seok; Lee, Min Yong; Jang Ho Ha

    2000-01-01

    The first cyclotron in Korea, MC-50 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-60{mu}A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23 days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed.

  11. Production of neutron deficient rare isotope beams at IGISOL; on-line and off-line studies

    NARCIS (Netherlands)

    Huikari, J; Dendooven, P; Jokinen, A; Nieminen, A; Penttila, H; Perajarvi, K; Popov, A; Rinta-Antila, S; Aysto, J

    2004-01-01

    This article reports on recent on-line yield measurements employing the light-ion and heavy-ion reaction-based ion guide systems and new results on a-recoil ion transport properties in ion guides with and without electric fields. In addition, the presently used ion guide designs for fusion evaporati

  12. Commercial compact cyclotrons in the 90`s

    Energy Technology Data Exchange (ETDEWEB)

    Milton, B.F.

    1995-09-01

    Cyclotrons continue to be efficient accelerators for radio-isotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicate a strong future for commercial cyclotrons. In this paper the authors will survey recent developments in the areas of cyclotron technology, as they relate to the new generation of commercial cyclotrons. Design criteria for the different types of commercial cyclotrons will be presented, with reference to those demands that differ from those in a research oriented cyclotron project. The authors also discuss the possibility of systems designed for higher energies and capable of extracted beam currents of up to 2.0 mA.

  13. The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source.

    Science.gov (United States)

    Tarvainen, O; Orpana, J; Kronholm, R; Kalvas, T; Laulainen, J; Koivisto, H; Izotov, I; Skalyga, V; Toivanen, V

    2016-09-01

    The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O(3+)-O(7+) were recorded at various tuner positions and frequencies in the range of 14.00-14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited "mode-hopping" between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

  14. The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source

    Science.gov (United States)

    Tarvainen, O.; Orpana, J.; Kronholm, R.; Kalvas, T.; Laulainen, J.; Koivisto, H.; Izotov, I.; Skalyga, V.; Toivanen, V.

    2016-09-01

    The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O3+-O7+ were recorded at various tuner positions and frequencies in the range of 14.00-14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited "mode-hopping" between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

  15. The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O., E-mail: olli.tarvainen@jyu.fi; Orpana, J.; Kronholm, R.; Kalvas, T.; Laulainen, J.; Koivisto, H. [Department of Physics (JYFL), University of Jyväskylä, 40500 Jyväskylä (Finland); Izotov, I.; Skalyga, V. [Institute of Applied Physics, RAS, 46 Ul’yanova St., 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., 603950 Nizhny Novgorod (Russian Federation); Toivanen, V. [European Organization for Nuclear Research (CERN), 1211 Geneva 23 (Switzerland)

    2016-09-15

    The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O{sup 3+}–O{sup 7+} were recorded at various tuner positions and frequencies in the range of 14.00–14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited “mode-hopping” between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

  16. The INSIDE project: on-line monitoring and simulation validation with the in-beam PET scanner

    Science.gov (United States)

    Ferrero, V.; INSIDE Collaboration

    2017-05-01

    The quality assurance of particle therapy treatment is a fundamental issue that can be addressed by developing reliable monitoring techniques and indicators of the treatment plan accuracy. Monitoring using Position Emission Tomography (PET) systems is the only in-vivo non invasive technique employed clinically and has been carried out in particle therapy since 1997. However, the PET monitoring of β + emitter isotopes is typically done after the treatment, resulting in a large fraction of lost data because of the isotopes rapid physical decay. The INSIDE collaboration has recently installed an in-beam PET scanner at the Italian National Center of Oncologic Hadrontherapy in Pavia, Italy. Here, there is an ongoing project in order to start testing the method on patients. This work focuses on the online performances of the scanner with clinical beams.

  17. Monitoring tumor motion with on-line mega-voltage cone-beam computed tomography imaging in a cine mode

    Energy Technology Data Exchange (ETDEWEB)

    Reitz, Bodo [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States); Gayou, Olivier [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States); Parda, David S [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States); Miften, Moyed [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States)

    2008-02-21

    Accurate daily patient localization is becoming increasingly important in external-beam radiotherapy (RT). Mega-voltage cone-beam computed tomography (MV-CBCT) utilizing a therapy beam and an on-board electronic portal imager can be used to localize tumor volumes and verify the patient's position prior to treatment. MV-CBCT produces a static volumetric image and therefore can only account for inter-fractional changes. In this work, the feasibility of using the MV-CBCT raw data as a fluoroscopic series of portal images to monitor tumor changes due to e.g. respiratory motion was investigated. A method was developed to read and convert the CB raw data into a cine. To improve the contrast-to-noise ratio on the MV-CB projection data, image post-processing with filtering techniques was investigated. Volumes of interest from the planning CT were projected onto the MV-cine. Because of the small exposure and the varying thickness of the patient depending on the projection angle, soft-tissue contrast was limited. Tumor visibility as a function of tumor size and projection angle was studied. The method was well suited in the upper chest, where motion of the tumor as well as of the diaphragm could be clearly seen. In the cases of patients with non-small cell lung cancer with medium or large tumor masses, we verified that the tumor mass was always located within the PTV despite respiratory motion. However for small tumors the method is less applicable, because the visibility of those targets becomes marginal. Evaluation of motion in non-superior-inferior directions might also be limited for small tumor masses. Viewing MV-CBCT data in a cine mode adds to the utility of MV-CBCT for verification of tumor motion and for deriving individualized treatment margins.

  18. Monitoring tumor motion with on-line mega-voltage cone-beam computed tomography imaging in a cine mode

    Science.gov (United States)

    Reitz, Bodo; Gayou, Olivier; Parda, David S.; Miften, Moyed

    2008-02-01

    Accurate daily patient localization is becoming increasingly important in external-beam radiotherapy (RT). Mega-voltage cone-beam computed tomography (MV-CBCT) utilizing a therapy beam and an on-board electronic portal imager can be used to localize tumor volumes and verify the patient's position prior to treatment. MV-CBCT produces a static volumetric image and therefore can only account for inter-fractional changes. In this work, the feasibility of using the MV-CBCT raw data as a fluoroscopic series of portal images to monitor tumor changes due to e.g. respiratory motion was investigated. A method was developed to read and convert the CB raw data into a cine. To improve the contrast-to-noise ratio on the MV-CB projection data, image post-processing with filtering techniques was investigated. Volumes of interest from the planning CT were projected onto the MV-cine. Because of the small exposure and the varying thickness of the patient depending on the projection angle, soft-tissue contrast was limited. Tumor visibility as a function of tumor size and projection angle was studied. The method was well suited in the upper chest, where motion of the tumor as well as of the diaphragm could be clearly seen. In the cases of patients with non-small cell lung cancer with medium or large tumor masses, we verified that the tumor mass was always located within the PTV despite respiratory motion. However for small tumors the method is less applicable, because the visibility of those targets becomes marginal. Evaluation of motion in non-superior-inferior directions might also be limited for small tumor masses. Viewing MV-CBCT data in a cine mode adds to the utility of MV-CBCT for verification of tumor motion and for deriving individualized treatment margins.

  19. A line-of-sight electron cyclotron emission receiver for electron cyclotron resonance heating feedback control of tearing modes

    DEFF Research Database (Denmark)

    Oosterbeek, J.W.; Bürger, A.; Westerhof, E.;

    2008-01-01

    An electron cyclotron emission (ECE) receiver inside the electron cyclotron resonance heating (ECRH) transmission line has been brought into operation. The ECE is extracted by placing a quartz plate acting as a Fabry-Perot interferometer under an angle inside the electron cyclotron wave (ECW) beam...

  20. Production of chemically reactive radioactive ion beams through on-line separation; Production de faisceaux d'ions radioactifs chimiquement reactifs par separation en ligne

    Energy Technology Data Exchange (ETDEWEB)

    Joinet, A

    2003-10-01

    The ISOL (isotope separation on line) allows the production of secondary radioactive ion beams through spallation or fragmentation or fission reactions that take place in a thick target bombarded by a high intensity primary beam. The challenge is to increase the intensity and purity of the radioactive beam. The optimization of the system target/source requires the right choice of material for the target by taking into account the stability of the material, its reactivity and the ionization method used. The target is an essential part of the system because radioactive elements are generated in it and are released more or less quickly. Tests have been made in order to select the best fitted material for the release of S, Se, Te, Ge and Sn. Materials tested as target filling are: ZrO{sub 2}, Nb, Ti, V,TiO{sub 2}, CeO{sub x}, ThO{sub 2}, C, ZrC{sub 4} and VC). Other molecules such as: COSe, COS, SeS, COTe, GeS, SiS, SnS have been studied to ease the extraction of recoil nuclei (Se, S, Te, Ge and Sn) produced inside the target.

  1. Ion sources for cyclotron applications

    Energy Technology Data Exchange (ETDEWEB)

    Leung, K.N.; Bachman, D.A.; McDonald, D.S.; Young, A.T.

    1992-07-01

    The use of a multicusp plasma generator as an ion source has many advantages. The development of both positive and negative ion beams based on the multicusp source geometry is presented. It is shown that these sources can be operated at steady state or cw mode. As a result they are very suitable for cyclotron operations.

  2. Non-inductive current built-up by local electron cyclotron heating and current drive with a 28 GHz focused beam on QUEST

    Science.gov (United States)

    Onchi, Takumi; Idei, Hiroshi; Hasegawa, Makoto; Ohwada, Hiroaki; Zushi, Hideki; Hanada, Kazuaki; Kariya, Tsuyoshi; Mishra, Kishore; Shikama, Taichi; Quest Team

    2016-10-01

    The plasma current can be driven solely by injecting electron cyclotron waves (ECWs) in spherical tokamak (ST) configuration. A system of 28 GHz gyrotron (maximum power: 270 kW) is renewed and reinstalled on QUEST. A focused ECW beam, whose diameter is about 5 cm at the second harmonic resonance, is injected for local ECW heating and current drive. The local power density at resonance exceeds 75 MW/m2 at an injection power of 150 kW. The incident ECW polarization can be adjusted employing the phase shifter consisting of two corrugated plates. During 1.25 second pulse of ECH, plasma current is built up to Ip = 70 kA fully non-inductively with a core electron density of ne > 1018 m-3. The closed flux in such ST plasma is determined at the inboard limiter on the center stack. Energetic electrons are also responsible for the pressure and equilibrium. This work is supported by JSPS KAKENHI (15H04231, 15K17800), NIFS Collaboration Research program (NIFS13KUTR085, NIFS11KUTR069, NIFS16KUTR114).

  3. Beam Dynamics Studies of ECR Injections for the Coupled Cyclotron Facility at NSCL%NSCL从ECR离子源向CCF注入的离子束流动力学研究

    Institute of Scientific and Technical Information of China (English)

    X.Wu; Q.Zhao; D.Cole; M.Doleans; G.Machicoane; F.Marti; P.Miller; J.Stetson; M.Steiner; P.Zavodszky

    2007-01-01

    The Coupled Cyclotron Facility(CCF)has been operating at the NSCL since 2001,providing up to 160MeV/u heavy ion beams for nuclear physics experiments.Recent steps,particularly the improvement of the ECR-to-K500 injection line,were taken to improve the CCF performance.For that purpose an off-line ECR source.ARTEMIS-B,was built and used to investigate the impact on beam brightness under various source operating conditions,different initial focusing systems and current analysis dipole.Beam dynamics simulations including space-charge and 3D electrostatic field effects were performed and beam diagnostics including emittance scanner were used,leading to a better understanding of the CCF beam injection process New initial electrostatic focusing elements such as a large-bore quadrupole triplet and a quadrupole doubledoublet with compensating octupole were tested,and a new beam tuning procedure was established to improve the beam brightness for the CCF.Following these efforts,a significant increase of primary beam power out of the CCF has been achieved.

  4. Shielding Design for a Medical Cyclotron

    Institute of Scientific and Technical Information of China (English)

    WANG; Feng; SONG; Guo-fang; GUAN; Feng-ping; LV; Yin-long; ZHANG; Xing-zhi

    2012-01-01

    <正>A 10 MeV 100 μA medical cyclotron is constructed at CIAE which is used in the production of FDG. The energy of the cyclotron can reach 14 MeV by adjusting the magnetic field and RF system parameters, and the shielding design is in accordance with the 14 MeV beam energy. In this shielding design only neutron is considered, and the neutron source is produced by proton

  5. Commercial compact cyclotrons in the 90's

    Energy Technology Data Exchange (ETDEWEB)

    Milton, B.F

    1995-09-01

    Cyclotrons continue to be efficient accelerators for radio-isotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicate a strong future for commercial cyclotrons. In this paper we will survey recent developments in the areas of cyclotron technology, as they relate to the new generation of commercial cyclotrons. Design criteria for the different types of commercial cyclotrons will be presented, with reference to those demands that differ from those in a research oriented cyclotron project. We will also discuss the possibility of systems designed for higher energies and capable of extracted beam currents of up to 2.0 mA. (author)

  6. Beam dump system design for 100 MeV high intensity proton cyclotron%100 MeV强流质子回旋加速器束流调试靶系统

    Institute of Scientific and Technical Information of China (English)

    贾先禄; 张天爵; 王峰; 吕银龙; 魏素敏; 毕远杰; 宋国芳; 解怀东

    2013-01-01

    中国原子能科学研究院正在建造一台100 MeV,200 μA的强流质子回旋加速器,需要使用束流调试靶来调试加速器,为此设计了一套束流功率为20 kW的质子束调试系统.对该系统的束流输运线、靶材料的选取、靶结构、水冷计算、屏蔽结构等作了介绍.给出了整条束流输运线的匹配计算结果;通过对质子打靶后的中子产额、角通量、靶的活化等方面的比较,最终选用铝作为靶材料;根据加速器引出束流能量和功率,设计了分层式靶结构,同时对靶进行了水冷计算;打靶产生的出射粒子平均能量较高,导致产生的辐射剂量很大,考虑到对环境与工作人员的影响及费用,需要对其进行局部屏蔽,给出了屏蔽计算结果及屏蔽结构的设计.%A 100 MeV proton cyclotron, referred to as CYCIAE-100, is designed to provide proton beams with energy up to 200 μA. When the cyclotron is under commissioning, a beam dump is required to measure the beam with a power of 20 kW. The paper introduces the beam line, target material selecting, target configuration, cooling calculation and the local shielding structure. The calculation result of the beam line matching is given. After comparing the neutron yield, flux angle and thermal activation of the targets of different materials by the proton targeting, the aluminum is selected as the target material. Based on the extraction beam energy and power of the cyclotron, a layered target configuration is designed, and the cooling calculation result is presented. The average energy of the emergent particle produced by the proton targeting is relatively high, so it will produce large radiation dose. Considering the harmful effect on the environment and personnel, the local shielding is selected for use. The calculation result and configuration of the local shielding are also presented in the paper.

  7. Nuclear physics with superconducting cyclotron at Kolkata: Scopes and possibilities

    Indian Academy of Sciences (India)

    Sailajananda Bhattacharya

    2010-08-01

    The K500 superconducting cyclotron at the Variable Energy Cyclotron Centre, Kolkata, India is getting ready to deliver its first accelerated ion beam for experiment. At the same time, the nuclear physics programme and related experimental facility development activities are taking shape. A general review of the nuclear physics research opportunities with the superconducting cyclotron and the present status of the development of different detector arrays and other experimental facilities will be presented.

  8. SC Cyclotron and RIB Facilities in Kolkata

    CERN Document Server

    Sinha, Bikash; Chakrabarti, Alok

    2005-01-01

    The superconducting cyclotron under construction at this Centre has bending limit (K-bend) of 520 and focusing limit (K-foc) of 160. It is being constructed, primarily, for nuclear physics experiments with heavy ion beams at intermediate energies. The 100-ton main magnet is currently in the commissioning phase with the main coil already at 4.2K temperature. Magnetic field measurements will be carried out over the next several months. All other systems of the cyclotron are in an advanced stage of fabrication or development. We plan to start assembly of the complete cyclotron around the end of 2005. In the phase-I of the project one beam line has been provided. Construction of three more beam lines and various experimental facilities for nuclear physics as well as irradiation experiments has also been funded and the work is well on its way. An ISOL type Radioactive Ion Beam (RIB) facility is being built with the existing K=130 room temperature cyclotron, VEC, as the primary beam source. In-beam RIB production a...

  9. Cyclotron waves in plasma

    CERN Document Server

    Lominadze, D G

    2013-01-01

    Cyclotron Waves in Plasma is a four-chapter text that covers the basic physical concepts of the theory of cyclotron waves and cyclotron instabilities, brought about by the existence of steady or alternating plasma currents flowing perpendicular to the magnetic field.This book considers first a wide range of questions associated with the linear theory of cyclotron oscillations in equilibrium plasmas and in electron plasmas in metals and semiconductors. The next chapter deals with the parametric excitation of electron cyclotron oscillations in plasma in an alternating electric field. A chapter f

  10. Cyclotron-based neutron source for BNCT

    Science.gov (United States)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K.; Tanaka, H.; Sakurai, Y.; Maruhashi, A.

    2013-04-01

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation & treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8×109 neutrons/cm2/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with 10B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  11. Cyclotron-based neutron source for BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K. [Sumitomo Heavy Industries, Ltd (Japan); Tanaka, H.; Sakurai, Y.; Maruhashi, A. [Kyoto University Research Reactor Institute (Japan)

    2013-04-19

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation and treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8 Multiplication-Sign 109 neutrons/cm{sup 2}/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with {sup 10}B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  12. Space-charge compensation measurements in electron cyclotron resonance ion source low energy beam transport lines with a retarding field analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Winklehner, D.; Leitner, D., E-mail: leitnerd@nscl.msu.edu; Cole, D.; Machicoane, G.; Tobos, L. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States)

    2014-02-15

    In this paper we describe the first systematic measurement of beam neutralization (space charge compensation) in the ECR low energy transport line with a retarding field analyzer, which can be used to measure the potential of the beam. Expected trends for the space charge compensation levels such as increase with residual gas pressure, beam current, and beam density could be observed. However, the overall levels of neutralization are consistently low (<60%). The results and the processes involved for neutralizing ion beams are discussed for conditions typical for ECR injector beam lines. The results are compared to a simple theoretical beam plasma model as well as simulations.

  13. Undergraduate Education with the Rutgers 12-Inch Cyclotron

    Science.gov (United States)

    Koeth, Timothy W.

    The Rutgers 12-Inch Cyclotron is a research grade accelerator dedicated to undergraduate education. From its inception, it has been intended for instruction and has been designed to demonstrate classic beam physics phenomena and provides students hands on experience with accelerator technology. The cyclotron is easily reconfigured, allowing experiments to be designed and performed within one academic semester. Our cyclotron offers students the opportunity to operate an accelerator and directly observe many fundamental beam physics concepts, including axial and radial betatron motion, destructive resonances, weak and azimuthally varying field (AVF) focusing schemes, RF and DEE voltage effects, diagnostic techniques, and perform low energy nuclear reactions. This paper emphasizes the unique beam physics measurements and beam manipulations capable at the Rutgers 12-Inch Cyclotron.

  14. A new generation of medical cyclotrons for the 90`s

    Energy Technology Data Exchange (ETDEWEB)

    Milton, B.F.

    1995-08-01

    Cyclotrons continue to be efficient accelerators for use in radio-isotope production. In recent years, developments in accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper the authors will survey recent developments in the areas of cyclotron technology as they relate to the new generation of commercial cyclotrons. Existing and potential markets for these cyclotrons will be presented. They will also discuss the possibility of systems capable of extracted energies up to 150 MeV and extracted beam currents of up to 2.0 mA.

  15. Measurement and Simulation of Beam Centering on CYCIAE-10

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The beam centering is very important for the compact cyclotron, especially for the cyclotrons with the axial injection. It is critical that the cyclotron has a good beam centering to increase the beam current and reduce the beam loss. In the accelerating process,

  16. The Leuven isotope separator on-line laser ion source

    CERN Document Server

    Kudryavtsev, Y; Franchoo, S; Huyse, M; Gentens, J; Kruglov, K; Müller, W F; Prasad, N V S; Raabe, R; Reusen, I; Van den Bergh, P; Van Duppen, P; Van Roosbroeck, J; Vermeeren, L; Weissman, L

    2002-01-01

    An element-selective laser ion source has been used to produce beams of exotic radioactive nuclei and to study their decay properties. The operational principle of the ion source is based on selective resonant laser ionization of nuclear reaction products thermalized and neutralized in a noble gas at high pressure. The ion source has been installed at the Leuven Isotope Separator On-Line (LISOL), which is coupled on-line to the cyclotron accelerator at Louvain-la-Neuve. sup 5 sup 4 sup , sup 5 sup 5 Ni and sup 5 sup 4 sup , sup 5 sup 5 Co isotopes were produced in light-ion-induced fusion reactions. Exotic nickel, cobalt and copper nuclei were produced in proton-induced fission of sup 2 sup 3 sup 8 U. The b decay of the sup 6 sup 8 sup - sup 7 sup 4 Ni, sup 6 sup 7 sup - sup 7 sup 0 Co, sup 7 sup 0 sup - sup 7 sup 5 Cu and sup 1 sup 1 sup 0 sup - sup 1 sup 1 sup 4 Rh isotopes has been studied by means of beta-gamma and gamma-gamma spectroscopy. Recently, the laser ion source has been used to produce neutron-d...

  17. ECR Ion Source for a High-Brightness Cyclotron

    Science.gov (United States)

    Comeaux, Justin; McIntyre, Peter; Assadi, Saeed

    2011-10-01

    New technology is being developed for high-brightness, high-current cyclotrons with performance benefits for accelerator-driven subcritical fission power, medical isotope production, and proton beam cancer therapy. This paper describes the design for a 65 kV electron cyclotron resonance (ECR) ion source that will provide high-brightness beam for injection into the cyclotron. The ion source is modeled closely upon the one that is used at the Paul Scherrer Institute. Modifications are being made to provide enhanced brightness and compatibility for higher-current operation.

  18. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    Science.gov (United States)

    Jang, Hyojae; Jin, Hyunchang; Jang, Ji-Ho; Hong, In-Seok

    2016-02-01

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

  19. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hyojae, E-mail: lkcom@ibs.re.kr; Jin, Hyunchang; Jang, Ji-Ho; Hong, In-Seok [Rare Isotope Science Project, Institute for Basic Science, Daejeon (Korea, Republic of)

    2016-02-15

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

  20. Suppression of cyclotron instability in Electron Cyclotron Resonance ion sources by two-frequency heating

    Energy Technology Data Exchange (ETDEWEB)

    Skalyga, V. [Institute of Applied Physics of Russian Academy of Sciences, 46 Ulyanova st., Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina st., Nizhny Novgorod (Russian Federation); Izotov, I.; Mansfeld, D. [Institute of Applied Physics of Russian Academy of Sciences, 46 Ulyanova st., Nizhny Novgorod (Russian Federation); Kalvas, T.; Koivisto, H.; Komppula, J.; Kronholm, R.; Laulainen, J.; Tarvainen, O. [Department of Physics, University of Jyväskylä, Jyväskylä (Finland)

    2015-08-15

    Multiple frequency heating is one of the most effective techniques to improve the performance of Electron Cyclotron Resonance (ECR) ion sources. The method increases the beam current and average charge state of the extracted ions and enhances the temporal stability of the ion beams. It is demonstrated in this paper that the stabilizing effect of two-frequency heating is connected with the suppression of electron cyclotron instability. Experimental data show that the interaction between the secondary microwave radiation and the hot electron component of ECR ion source plasmas plays a crucial role in mitigation of the instabilities.

  1. Effect of frequency tuning on bremsstrahlung spectra, beam intensity, and shape in the 10 GHz NANOGAN electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, G., E-mail: gerosro@gmail.com; Mal, Kedar; Kumar, Narender; Lakshmy, P. S.; Mathur, Y.; Kumar, P.; Kanjilal, D.; Roy, A. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi (India); Baskaran, R. [Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu (India)

    2014-02-15

    Studies on the effect of the frequency tuning on the bremsstrahlung spectra, beam intensities, and beam shape of various ions have been carried out in the 10 GHz NANOGAN ECR ion source. The warm and cold components of the electrons were found to be directly correlated with beam intensity enhancement in case of Ar{sup 9+} but not so for O{sup 5+}. The warm electron component was, however, much smaller compared to the cold component. The effect of the fine tuning of the frequency on the bremsstrahlung spectrum, beam intensities and beam shape is presented.

  2. Multicavity proton cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    J. L. Hirshfield

    2002-08-01

    Full Text Available A mechanism for acceleration of protons is described, in which energy gain occurs near cyclotron resonance as protons drift through a sequence of rotating-mode TE_{111} cylindrical cavities in a strong nearly uniform axial magnetic field. Cavity resonance frequencies decrease in sequence from one another with a fixed frequency interval Δf between cavities, so that synchronism can be maintained between the rf fields and proton bunches injected at intervals of 1/Δf. An example is presented in which a 122 mA, 1 MeV proton beam is accelerated to 961 MeV using a cascade of eight cavities in an 8.1 T magnetic field, with the first cavity resonant at 120 MHz and with Δf=8 MHz. Average acceleration gradient exceeds 40 MV/m, average effective shunt impedance is 223 MΩ/m, but maximum surface field in the cavities does not exceed 7.2 MV/m. These features occur because protons make many orbital turns in each cavity and thus experience acceleration from each cavity field many times. Longitudinal and transverse stability appear to be intrinsic properties of the acceleration mechanism, and an example to illustrate this is presented. This acceleration concept could be developed into a proton accelerator for a high-power neutron spallation source, such as that required for transmutation of nuclear waste or driving a subcritical fission burner, provided a number of significant practical issues can be addressed.

  3. Alfven cyclotron instability and ion cyclotron emission

    Energy Technology Data Exchange (ETDEWEB)

    Gorelenkov, N.N.; Cheng, C.Z.

    1995-07-01

    Two-dimensional solutions of compressional Alfven eigenmodes (CAE) are studied in the cold plasma approximation. For finite inverse aspect ratio tokamak plasmas the two-dimensional eigenmode envelope is localized at the low magnetic field side with the radial and poloidal localization on the order of a/{radical}m and a/(fourth root of m), respectively, where m is the dominant poloidal mode number. Charged fusion product driven Alfven Cyclotron Instability (ACI) of the compressional Alfven eigenmodes provides the explanation for the ion cyclotron emission (ICE) spectrum observed in tokamak experiments. The ACI is excited by fast charged fusion products via Doppler shifted cyclotron wave-particle resonances. The ion cyclotron and electron Landau dampings and fast particle instability drive are calculated perturbatively for deuterium-deuterium (DD) and deuterium-tritium (DT) plasmas. Near the plasma edge at the low field side the velocity distribution function of charged fusion products is localized in both pitch angle and velocity. The poloidal localization of the eigenmode enhances the ACI growth rates by a factor of {radical}m in comparison with the previous results without poloidal envelope. The thermal ion cyclotron damping determines that only modes with eigenfrequencies at multiples of the edge cyclotron frequency of the background ions can be easily excited and form an ICE spectrum similar to the experimental observations. Theoretical understanding is given for the results of TFTR DD and DT experiments with {upsilon}{sub {alpha}0}/{upsilon}{sub A} < 1 and JET experiments with {upsilon}{sub {alpha}0}/{upsilon}{sub A} > 1.

  4. Injection and extraction for cyclotrons

    CERN Document Server

    Kleeven, W

    2006-01-01

    The main design goals for beam injection are explained and special problems related to a central region with internal ion source are considered. The principle of a PIG source is addressed. The issue of vertical focusing in the cyclotron centre is briefly discussed. Several examples of numerical simulations are given. Different ways of (axial) injection are briefly outlined. A proposal for a magnetostatic axial inflector is given. Different solutions for beam extraction are treated. These include the internal target, extraction by stripping, resonant extraction using a deflector and self-extraction. The different ways of creating a turn-separation are explained. The purpose of different types of extraction devices such as harmonic coils, deflectors and gradient corrector channels are outlined. Several illustrations are given in the form of photographs and drawings.

  5. Low energy cyclotron for radiocarbon dating

    Energy Technology Data Exchange (ETDEWEB)

    Welch, J.J.

    1984-12-01

    The measurement of naturally occurring radioisotopes whose half lives are less than a few hundred million years but more than a few years provides information about the temporal behavior of geologic and climatic processes, the temporal history of meteoritic bodies as well as the production mechanisms of these radioisotopes. A new extremely sensitive technique for measuring these radioisotopes at tandem Van de Graaff and cyclotron facilities has been very successful though the high cost and limited availability have been discouraging. We have built and tested a low energy cyclotron for radiocarbon dating similar in size to a conventional mass spectrometer. These tests clearly show that with the addition of a conventional ion source, the low energy cyclotron can perform the extremely high sensitivity /sup 14/C measurements that are now done at accelerator facilities. We found that no significant background is present when the cyclotron is tuned to accelerate /sup 14/C negative ions and the transmission efficiency is adequate to perform radiocarbon dating on milligram samples of carbon. The internal ion source used did not produce sufficient current to detect /sup 14/C directly at modern concentrations. We show how a conventional carbon negative ion source, located outside the cyclotron magnet, would produce sufficient beam and provide for quick sampling to make radiocarbon dating milligram samples with a modest laboratory instrument feasible.

  6. The Warsaw K=160 cyclotron

    Science.gov (United States)

    Choinski, J.; Miszczak, J.; Sura, J.

    2001-12-01

    The overview of the Warsaw cyclotron facility is presented. The facility consists of K=160 cyclotron, 10 GHz ECR ion source, and several experimental stations. The cyclotron is of compact design with 2 straight dees. A yearly operation time is about 2900 hours on an average for the past few years. The cyclotron can deliver beams up to Ar with energy up to 10 MeV/amu to the experimental area. Experimental stations are: 1) The multidetector OSIRIS II, allows the study of exotic nuclei in the double magic 100Sn region. The experimental set-up consists of 8 HPGe detectors equipped with charged particle 4π multiplicity filter SiBall, 50 elements BGO γ-rays multiplicity filter, 4 sector polarimeter and electron conversion detector system. 2) CUDAC-Coulomb Universal Detector Scattering Chamber-an array of PIN-diodes in connection with HPGe detectors and the computer data analysis package GOSIA, maintained by the Laboratory allows investigation the Coulomb Excitation (COULEX) reactions. 3) IGISOL or Helium-jet transport system opened investigation of the reaction products by means of the online mass separator with ion-guide system. The system uses the Scandinavian-type mass separator built in INR Świerk, Poland. 4) Giant Dipole Resonance studies using experimental set-up JANOSIK developed for the detection of high-energy photons emitted in heavy-ion collisions. The set-up consists of a large NaI(Tl) detector (25 cm×29 cm) surrounded by shields: passive lead shield, active anticoincidence plastic shield and LiH shield to absorb neutrons, and a multiplicity filter of 32 small scintillator detectors (BaF2 and NaI(Tl)). 5) Laser spectroscopy stand now in test phase. The laser spectroscopy group at HIL has completed an equipment consisting of Argon ion Laser Innova 400-25W in all lines and coherent Ring Laser 669-21 as well as atomic beam apparatus.

  7. Synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    The electromagnetic coil which forms the first section of the proton extraction channel in the improved synchro-cyclotron. The photograph shows the positioning gear and the current septum. An extraction efficiency above 50% is expected.

  8. The new cyclotrons

    CERN Multimedia

    Lawson, J D

    1966-01-01

    Article describing how valuable scientific work can still be carried out with the smaller energy cyclotrons such as those at the Radiochemical Centre, Amersham and the Atomic Energy Research Establishment, Harwell (2 pages).

  9. High-current cyclotron to drive an electronuclear assembly

    CERN Document Server

    Alenitsky, Yu G

    2002-01-01

    The proposal on creation of a high-current cyclotron complex for driving an electronuclear assembly reported at the 17th Meeting on Accelerators of Charged Particles is discussed. Some changes in the basic design parameters of the accelerator are considered in view of new results obtained in the recent works. It is shown that the cyclotron complex is now the most real and cheapest accelerator for production of proton beams with a power of up to 10 MW. Projects on design of a high-current cyclotron complex for driving an electronuclear subcritical assembly are presented.

  10. Vacuum Pre-designing for CYCIAE-230 Superconducting Cyclotron

    Institute of Scientific and Technical Information of China (English)

    ZHANG; Su-ping; PAN; Gao-feng; LI; Zhen-guo; QIN; Jiu-chang

    2015-01-01

    CYCIAE-230superconducting cyclotron has two separate vacuum system,one is for beam chamber,another is for cryostat.Beam chamber and cryostat shall maintain separate vacuum against atmospheric pressure.The pressure of pumps inlet is better than 1×10-4Pa and the

  11. On-line test using multi-foil SiC target at iThemba LABS

    Science.gov (United States)

    Monetti, A.; Bark, R. A.; Andrighetto, A.; Beukes, P.; Conradie, J. L.; Corradetti, S.; Fourie, D.; Lussi, C.; Manzolaro, M.; Meneghetti, G.; Prete, G.; Rossignoli, M.; Scarpa, D.; Van Schalkwyk, P.; Stoddart, N.; Vasquez, J.

    2016-06-01

    In a collaboration between the INFN-SPES project and iThemba LABS, an on-line test of the power dissipation of a multi-slice target concept for radioactive-ion beam production has been performed. Using the 66MeV proton beam from the iThemba LABS Separated Sector Cyclotron, a total power of 4kW was deposited in the target complex, consisting of 13 Silicon Carbide (SiC) discs of about 1 millimetre thickness housed in a graphite cylinder. The results of the measurements fully validate thermal FEM simulations and confirm that the multi-foil target system is a reliable and affordable device for second-generation ISOL-RIB facilities like SPES.

  12. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole.

    Science.gov (United States)

    Rodrigues, G; Becker, R; Hamm, R W; Baskaran, R; Kanjilal, D; Roy, A

    2014-02-01

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged (238)U(40+) (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  13. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, G., E-mail: gerosro@gmail.com; Kanjilal, D.; Roy, A. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi (India); Becker, R. [Institut fur Angewandte Physik der Universitaet, D-60054 Frankfurt/M (Germany); Hamm, R. W. [R and M Technical Enterprises, Inc., 4725 Arlene Place, Pleasanton, California 94566 (United States); Baskaran, R. [Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu (India)

    2014-02-15

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged {sup 238}U{sup 40+} (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  14. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

    Science.gov (United States)

    Rodrigues, G.; Becker, R.; Hamm, R. W.; Baskaran, R.; Kanjilal, D.; Roy, A.

    2014-02-01

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged 238U40+ (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  15. Single photon ionization time-of-flight mass spectrometry with a pulsed electron beam pumped excimer VUV lamp for on-line gas analysis: setup and first results on cigarette smoke and human breath.

    Science.gov (United States)

    Mühlberger, F; Streibel, T; Wieser, J; Ulrich, A; Zimmermann, R

    2005-11-15

    Single-photon ionization (SPI) using vacuum ultraviolet (VUV) light produced by an electron beam pumped rare gas excimer source has been coupled to a compact and mobile time-of-flight mass spectrometer (TOFMS). The novel device enables real-time on-line monitoring of organic trace substances in complex gaseous matrixes down to the ppb range. The pulsed VUV radiation of the light source is employed for SPI in the ion source of the TOFMS. Ion extraction is also carried out in a pulsed mode with a short time delay with respect to ionization. The experimental setup of the interface VUV light source/time-of-flight mass spectrometer is described, and the novel SPI-TOFMS system is characterized by means of standard calibration gases. Limits of detection down to 50 ppb for aliphatic and aromatic hydrocarbons were achieved. First on-line applications comprised real-time measurements of aromatic and aliphatic trace compounds in mainstream cigarette smoke, which represents a highly dynamic fluctuating gaseous matrix. Time resolution was sufficient to monitor the smoking process on a puff-by-puff resolved basis. Furthermore, human breath analysis has been carried out to detect differences in the breath of a smoker and a nonsmoker, respectively. Several well-known biomarkers for smoke could be identified in the smoker's breath. The possibility for even shorter measurement times while maintaining the achieved sensitivity makes this new device a promising tool for on-line analysis of organic trace compounds in process gases or biological systems.

  16. Generation of multi-charged high current ion beams using the SMIS 37 gas-dynamic electron cyclotron resonance (ECR) ion source

    Energy Technology Data Exchange (ETDEWEB)

    Dorf, M. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zorin, V. G. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Sidorov, A. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Bokhanov, A. F. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Izotov, I. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Razin, S. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Skalyga, V. A. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics

    2013-06-02

    A gas-dynamic ECR ion source (GaDIS) is distinguished by its ability to produce high current and high brightness beams of moderately charged ions. Contrary to a classical ECR ion source where the plasma confinement is determined by the slow electron scattering into an empty loss-cone, the higher density and lower electron temperature in a GaDIS plasma lead to an isotropic electron distribution with the confinement time determined by the prompt gas-dynamic flow losses. As a result, much higher ion fluxes are available, however a decrease in the confinement time of the GaDIS plasma lowers the ion charge state. The gas-dynamic ECR ion source concept has been successfully realized in the SMIS 37 experimental facility operated at the Institute of Applied Physics, Russia. The use of high-power (~100 kW) microwave (37.5 GHz) radiation provides a dense plasma (~1013 cm-3) with a relatively low electron temperature (~50- 100 eV) and allows for the generation of high current (~1 A/cm2) beams of multi-charged ions. In this work we report on the present status of the SMIS 37 ion source and discuss the advanced numerical modeling of ion beam extraction using the particle-in-cell code WARP

  17. Generation of multi-charged high current ion beams using the SMIS 37 gas-dynamic electron cyclotron resonance (ECR) ion source

    Energy Technology Data Exchange (ETDEWEB)

    Dorf, M.A., E-mail: dorf1@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Zorin, V.G.; Sidorov, A.V.; Bokhanov, A.F.; Izotov, I.V.; Razin, S.V.; Skalyga, V.A. [Institute of Applied Physics RAS, 46 Ulyanov Street, 603950 Nizhny Novgorod (Russian Federation)

    2014-01-01

    A gas-dynamic ECR ion source (GaDIS) is distinguished by its ability to produce high current and high brightness beams of moderately charged ions. Contrary to a classical ECR ion source where the plasma confinement is determined by the slow electron scattering into an empty loss-cone, the higher density and lower electron temperature in a GaDIS plasma lead to an isotropic electron distribution with the confinement time determined by the prompt gas-dynamic flow losses. As a result, much higher ion fluxes are available; however a decrease in the confinement time of the GaDIS plasma lowers the ion charge state. The gas-dynamic ECR ion source concept has been successfully realized in the SMIS 37 experimental facility operated at the Institute of Applied Physics, Russia. The use of high-power (∼100 kW) microwave (37.5 GHz) radiation provides a dense plasma (∼10{sup 13} cm{sup −3}) with a relatively low electron temperature (∼50–100 eV) and allows for the generation of high current (∼1 A/cm{sup 2}) beams of multi-charged ions. In this work we report on the present status of the SMIS 37 ion source and discuss the advanced numerical modeling of ion beam extraction using the particle-in-cell code WARP.

  18. A hybrid electron cyclotron resonance metal ion source with integrated sputter magnetron for the production of an intense Al{sup +} ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Weichsel, T., E-mail: tim.weichsel@fep.fraunhofer.de; Hartung, U.; Kopte, T. [Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, 01277 Dresden (Germany); Zschornack, G. [Institute of Solid State Physics, Dresden University of Technology, 01062 Dresden, Germany and Helmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Dresden (Germany); Kreller, M.; Philipp, A. [DREEBIT GmbH, 01900 Grossroehrsdorf (Germany)

    2015-09-15

    A metal ion source prototype has been developed: a combination of magnetron sputter technology with 2.45 GHz electron cyclotron resonance (ECR) ion source technology—a so called magnetron ECR ion source (MECRIS). An integrated ring-shaped sputter magnetron with an Al target is acting as a powerful metal atom supply in order to produce an intense current of singly charged metal ions. Preliminary experiments show that an Al{sup +} ion current with a density of 167 μA/cm{sup 2} is extracted from the source at an acceleration voltage of 27 kV. Spatially resolved double Langmuir probe measurements and optical emission spectroscopy were used to study the plasma states of the ion source: sputter magnetron, ECR, and MECRIS plasma. Electron density and temperature as well as Al atom density were determined as a function of microwave and sputter magnetron power. The effect of ECR heating is strongly pronounced in the center of the source. There the electron density is increased by one order of magnitude from 6 × 10{sup 9} cm{sup −3} to 6 × 10{sup 10} cm{sup −3} and the electron temperature is enhanced from about 5 eV to 12 eV, when the ECR plasma is ignited to the magnetron plasma. Operating the magnetron at constant power, it was observed that its discharge current is raised from 1.8 A to 4.8 A, when the ECR discharge was superimposed with a microwave power of 2 kW. At the same time, the discharge voltage decreased from about 560 V to 210 V, clearly indicating a higher plasma density of the MECRIS mode. The optical emission spectrum of the MECRIS plasma is dominated by lines of excited Al atoms and shows a significant contribution of lines arising from singly ionized Al. Plasma emission photography with a CCD camera was used to prove probe measurements and to identify separated plasma emission zones originating from the ECR and magnetron discharge.

  19. Development of the cyclotron radioisotope production technology

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Yong Sup; Chun, K.S.; Yang, S.D.; Lee, J.D.; Ahn, S.H.; Yun, Y.K.; Park, H.; Lee, J.S.; Chai, J.S.; Kim, U.S.; Hong, S.S.; Lee, M.Y.; Park, C.W.; Baik, S. K.; Kim, E. H.; Kim, T. K.; Kim, K. S.; Kim, J. H

    1999-04-01

    The purpose of this study is to contribute the advance of nuclear medicine and to the improvement of human health through the development of various accelerator radionuclides and mass production with automization of production. The results obtained from this study are following: 1) In order to introduce 30 MeV high current cyclotron, the specification of cyclotron has been made, the building site was selected and we drew the draw-up of cyclotron. The cyclotron installation contract was postponed until the financial resources could be secured. 2) For a development high purity 1-123 producing system, a Xe-124 target system, a temperature measurement system of the inner part of the target and a target window were fabricated. A Xe-124 gas target recovery system and a full production system of 1-123 was drew up. 3) For a development of a therapeutic nuclide At-211, a target for the production of At-211 via {sup 209}Bi(alpha, 2n) reaction was fabricated. Produced At-211 was separated by distillation method. 4) For development of beta-emitting nuclides, Ti-45, C-11, F{sub 2}-18, beam irradiation system suitable for each target were fabricated. 5) For automatic production of Ga-67, automated module and PLC program was made 6) For the quality control of radiopharmaceuticals, analytical method of thallium and copper by polarography was investigated and established.

  20. Inflation and Cyclotron Motion

    CERN Document Server

    Greensite, Jeff

    2016-01-01

    We consider, in the context of a braneworld cosmology, the motion of the universe coupled to a four-form gauge field, with constant field strength, defined in higher dimensions. It is found, under rather general initial conditions, that in this situation there is a period of exponential inflation combined with cyclotron motion in the inflaton field space. The main effect of the cyclotron motion is that conditions on the flatness of the inflaton potential, which are typically necessary for exponential inflation, can be evaded. There are Landau levels associated with the four-form gauge field, and these correspond to quantum excitations of the inflaton field.

  1. Cyclotrons with Fast Variable and/or Multiple Energy Extraction

    CERN Document Server

    Baumgarten, C

    2013-01-01

    We discuss the principle possibility of stripping extraction in combination with reverse bends in isochronous separate sector cyclotrons (and/or FFAGs). If one uses reverse bends between the sectors (instead of drifts) and places stripper foils at the sector exit edges, the stripped beam has a reduced bending radius and it should be able to leave the cyclotron within the range of the reverse bend - even if the beam is stripped at less than full energy. We are especially interested in $H_2^+$-cyclotrons, which allow to double the charge to mass ratio by stripping. However the principle could be applied to other ions or ionized molecules as well. For the production of proton beams by stripping extraction of an $H_2^+$-beam, we discuss possible designs for three types of machines: First a low-energy cyclotron for the simultaneous production of several beams at multiple energies - for instance 15 MeV, 30 MeV and 70 MeV - thus allowing to have beam on several isotope production targets. In this case it is desired ...

  2. Status of the Cyclotron Institute Upgrade Project

    Science.gov (United States)

    Melconian, Dan

    2016-09-01

    The Texas A&M University Re-accelerated EXotics (T-REX) project, an upgrade to the Cyclotron Institute, will provide high-quality re-accelerated secondary beams of a unique energy range and the ability to provide primary beams to two experiments concurrently. The upgrade is nearing completion of its three major tasks: re-commissioning of the existing K150 cyclotron; construction of light- and heavy-ion guide transport systems; and charge-boosting the K150 RIB for re-acceleration using the K500 cyclotron. The light-ion guide transport system will utilize the high intensity (>= 10 μ A) proton beam from the K150 to produce rare ions via fusion-evapouration reactions or proton-induced fission fragments. These ions will be transported to an ECR charge breeder prior to injection in the K500. The heavy-ion guide will use deep inelastic, transfer and fragmentation reactions using the up to 25 MeV/u primary beams from the K150. The products will be separated by a superconducting solenoid and collected in a large gas-catcher, after which a multi-RFQ system will transport the RIB to any of: the charge-breeder and K500; the TAMU Penning Trap beamline; or an MR-TOF for beam analysis. The status of the T-REX upgrade and an overview of its capabilities will be presented Supported by DOE Grant Number DE-FG03-93ER40773 and the Robert A. Welch Foundation Grant Number H-A-0098.

  3. Variable-Energy Cyclotron for Proton Therapy Application

    CERN Document Server

    Alenitsky, Yu G; Vorozhtsov, A S; Glazov, A A; Mytsyn, G V; Molokanov, A G; Onishchenko, L M

    2004-01-01

    The requirements to characteristics of the beams used for proton therapy are considered. The operation and proposed cyclotrons for proton therapy are briefly described. The technical decisions of creation of the cyclotron with energy variation in the range 70-230 MeV and with current up to 100 nA are estimated. Taking into account the fact, that the size and cost of the cyclotron are approximately determined by the maximum proton energy, it is realistically offered to limit the maximum proton energy to 190 MeV and to elaborate a cyclotron project with a warm winding of the magnet for acceleration of H^{-} ions. The energy of the extracted protons for each run is determined by a stripped target radius in the vacuum chamber of the accelerator, and the radiation dose field for the patient is created by the external devices using the developed techniques.

  4. Design Study Of Cyclotron Magnet With Permanent Magnet

    Science.gov (United States)

    Kim, Hyun Wook; Chai, Jong Seo

    2011-06-01

    Low energy cyclotrons for Positron emission tomography (PET) have been wanted for the production of radio-isotopes after 2002. In the low energy cyclotron magnet design, increase of magnetic field between the poles is needed to make a smaller size of magnet and decrease power consumption. The Permanent magnet can support this work without additional electric power consumption in the cyclotron. In this paper the study of cyclotron magnet design using permanent magnet is shown and also the comparison between normal magnet and the magnet which is designed with permanent magnet is shown. Maximum energy of proton is 8 MeV and RF frequency is 79.3 MHz. 3D CAD design was done by CATIA P3 V5 R18 [1] and the All field calculations had been performed by OPERA-3D TOSCA [2]. The self-made beam dynamics program OPTICY [3] is used for making isochronous field and other calculations.

  5. Design of 10 MeV cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    R Solhju

    2015-09-01

    Full Text Available Design and construction of 10MeV cyclotron has been started at Amirkabir University of Technology since 2012. So far, the conceptual and detail engineering design phases have been finalized. The main purpose of this baby cyclotron is to generate proton beam for the production of PET radioisotopes. The cyclotron consists of magnet, cavity, ion source, RF and LLRF system, vacuum system, cooling system, power amplifiers and power supplies system. In this paper, a brief of design principles for all the parts of cyclotron and their final simulation results is presented. It should be noted that these simulations have been performed and optimized by the most accurate softwares such as TOSCA, ANSYS, HFSS, SolidWorks and CST. Also, the manufacturing feasibility of all the parts is performed and their dimensions and parameters are synchronized with manufacturing standards

  6. Upgrading Synchro-cyclotron

    CERN Multimedia

    1974-01-01

    Final touches to the central region of SC2, the refurbished 600 MeV synchro-cyclotron, before the start of commissioning. Modifications included a new type of ion source at the centre. Protons were first accelerated in SC2 at full energy by October 1974. (See photo 7408042X)

  7. Electron-Cyclotron Waves

    NARCIS (Netherlands)

    Westerhof, E.

    1994-01-01

    The essential elements of the theory of electron cyclotron waves are reviewed, The two main electro-magnetic modes of propagation are identified and their dispersion and absorption properties are discussed. The importance of the use of the relativistic resonance condition is stressed.

  8. Mean magnetic field calculation program with allowance for flutter for isochronous cyclotron (Cyclotron Analytic Model Program - CAMP)

    CERN Document Server

    Kiyan, I N; Vorozhtsov, S B

    2002-01-01

    The Cyclotron Analytic Model Program (CAMP) written in C++ with the use of Visual C++ is described. The program is intended for the mean magnetic field calculation of the isochronous cyclotron with allowance for flutter. The program algorithm was developed on the basis of the paper 'Calculation of Isochronous Fields for Sector-Focused Cyclotrons', by M.M.Gordon (Particle Accelerators. 1983. V.13). The accuracy of the calculations, performed with this program, was tested with the use of maps of isochronous magnetic fields of different cyclotrons with the azimuthally varying fields - AVF cyclotrons, in which the ion beams were produced. The calculation by CAMP showed that the isochronous mean magnetic field curve for the measured magnetic field, in which the ion beam was produced, exactly corresponded to the curve of the isochronous mean magnetic field, calculated with the allowance for flutter for all the AVF cyclotrons that were considered. As is evident from the calculations, this program can be used for cal...

  9. Monte-Carlo Simulation of Cryopanel Parameter in CYCIAE-100 Cyclotron

    Institute of Scientific and Technical Information of China (English)

    PAN; Gao-feng; ZHANG; Su-ping; XING; Jian-sheng; LI; Zhen-guo; QIN; Jiu-chang

    2015-01-01

    The diameter of CYCIAE-100cyclotron main magnet is 4m,the angle of magnet valley is 35°and its height is about 500mm.Due to restrictions on the size of compact cyclotron structure,the available vacuum suction space is limited.According to the beam loss theory,particles

  10. Improved charge breeding efficiency of light ions with an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Vondrasek, R.; Kutsaev, Sergey [Argonne National Laboratory, Argonne, Illinois 60439 (United States); Delahaye, P.; Maunoury, L. [Grand Accelerateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Blvd Henri Becquerel, 14076 Caen (France)

    2012-11-15

    The Californium Rare Isotope Breeder Upgrade is a new radioactive beam facility for the Argonne Tandem Linac Accelerator System (ATLAS). The facility utilizes a {sup 252}Cf fission source coupled with an electron cyclotron resonance ion source to provide radioactive beam species for the ATLAS experimental program. The californium fission fragment distribution provides nuclei in the mid-mass range which are difficult to extract from production targets using the isotope separation on line technique and are not well populated by low-energy fission of uranium. To date the charge breeding program has focused on optimizing these mid-mass beams, achieving high charge breeding efficiencies of both gaseous and solid species including 14.7% for the radioactive species {sup 143}Ba{sup 27+}. In an effort to better understand the charge breeding mechanism, we have recently focused on the low-mass species sodium and potassium which up to present have been difficult to charge breed efficiently. Unprecedented charge breeding efficiencies of 10.1% for {sup 23}Na{sup 7+} and 17.9% for {sup 39}K{sup 10+} were obtained injecting stable Na{sup +} and K{sup +} beams from a surface ionization source.

  11. Cyclotrons as Drivers for Precision Neutrino Measurements

    Directory of Open Access Journals (Sweden)

    A. Adelmann

    2014-01-01

    Full Text Available As we enter the age of precision measurement in neutrino physics, improved flux sources are required. These must have a well defined flavor content with energies in ranges where backgrounds are low and cross-section knowledge is high. Very few sources of neutrinos can meet these requirements. However, pion/muon and isotope decay-at-rest sources qualify. The ideal drivers for decay-at-rest sources are cyclotron accelerators, which are compact and relatively inexpensive. This paper describes a scheme to produce decay-at-rest sources driven by such cyclotrons, developed within the DAEδALUS program. Examples of the value of the high precision beams for pursuing Beyond Standard Model interactions are reviewed. New results on a combined DAEδALUS—Hyper-K search for CP violation that achieve errors on the mixing matrix parameter of 4° to 12° are presented.

  12. Vortex dynamics and shear layer instability in high intensity cyclotrons

    CERN Document Server

    Cerfon, Antoine J

    2016-01-01

    We show that the space charge dynamics of high intensity beams in the plane perpendicular to the magnetic field in cyclotrons is described by the two-dimensional Euler equations for an incompressible fluid. This analogy with fluid dynamics gives a unified and intuitive framework to explain the beam spiraling and beam break up behavior observed in experiments and in simulations. In particular, we demonstrate that beam break up is the result of a classical instability occurring in fluids subject to a sheared flow. We give scaling laws for the instability and predict the nonlinear evolution of beams subject to it. Our work suggests that cyclotrons may be uniquely suited for the experimental study of shear layers and vortex distributions that are not achievable in Penning-Malmberg traps.

  13. Electromagnetic Cyclotron Waves in the Solar Wind: Wind Observation and Wave Dispersion Analysis

    Science.gov (United States)

    Jian, L. K.; Moya, P. S.; Vinas, A. F.; Stevens, M.

    2016-01-01

    Wind observed long-lasting electromagnetic cyclotron waves near the proton cyclotron frequency on 11 March 2005, in the descending part of a fast wind stream. Bi-Maxwellian velocity distributions are fitted for core protons, beam protons, and alpha-particles. Using the fitted plasma parameters we conduct kinetic linear dispersion analysis and find ion cyclotron and/or firehose instabilities grow in six of 10 wave intervals. After Doppler shift, some of the waves have frequency and polarization consistent with observation, thus may be correspondence to the cyclotron waves observed.

  14. Status report of the Jyvaskyla ion guide isotope separator on-line facility

    NARCIS (Netherlands)

    Penttila, H; Dendooven, P; Honkanen, A; Huhta, M; Jauho, PP; Jokinen, A; Lhersonneau, G; Oinonen, M; Parmonen, JM; Perajarvi, K; Aysto, J

    1997-01-01

    The ion guide isotope separator facility IGISOL of the University of Jyvaskyla has been moved to the new K-130 heavy ion cyclotron laboratory. The totally reconstructed facility is described in detail. The primary beams and targets, helium pumping, separator beam line construction and separator beam

  15. Electron Cyclotron Emission Radiometer

    Science.gov (United States)

    Morales, Cristina

    2009-11-01

    There is much interest in studying plasmas that generate hot electrons. The goal of this project is to develop a wide band electron cyclotron radiometer to measure the non-Maxwellian rapid rises in electron temperature. These rapid increases in temperature will then be correlated to instabilities in the plasma. This project explores a type of noncontact temperature measurement. We will attempt to show the feasibility of electron cyclotron emissions to measure the Maryland Centrifugal Experiment's electron plasma temperature. The radiometer has been designed to have 100dB of gain and a sensitivity of 24mV/dB given by its logarithmic amplifier. If successful, this radiometer will be used as a diagnostic tool in later projects such as the proposed experiment studying magnetic reconnection using solar flux loops.

  16. Cyclotron Line Variability

    CERN Document Server

    Mihara, Tatehiro; Nagase, Fumiaki

    2014-01-01

    We systematically analyzed the spectra of X-ray binary pulsars observed with GINGA (Mihara 1995). A new model NPEX (Negative and Positive power-laws EXponential) was introduced t o represent the pulsar continuum. Combining the NPEX continuum with the CYAB factor (cyclotron resonance scattering model), we successfully fit the whole-band spectra of all the pulsars. A possible physical meaning of the NPEX model is the Comptonized spectra. By using the smooth and concave NPEX model, the cyclotron structures were detected from 12 pulsars, about a half of the 23 sources, including new discoveries from LMC X-4 and GS 1843+00. The magnetic fields were scattered in the range of $3\\times10^{11}$ - $5\\times10^{12}$ G. The distribution was shown for the first time, which is remarkably similar to that of radio pulsars with a peak at $2 \\times 10^{12}$ G. The double harmonic cyclotron structures of 4U 0115+63 in 1990 changed to a sin gle structure in 1991. The resonance energy also increased by 40 % as the luminosity decre...

  17. A new generation of medical cyclotrons for the 90's

    Energy Technology Data Exchange (ETDEWEB)

    Milton, B.F

    1995-08-01

    Cyclotrons continue to be efficient accelerators for use in radio-isotope production. In recent years, developments in accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper we will survey recent developments in the areas of cyclotron technology as they relate to the new generation of commercial cyclotrons. Existing and potential markets for these cyclotrons will be presented. We will also discuss the possibility of systems capable of extracted energies up to 150 MeV and extracted beam currents of up to 2.0 mA. (author)

  18. Emittance Measurement for Beamline Extension at the PET Cyclotron

    Directory of Open Access Journals (Sweden)

    Sae-Hoon Park

    2016-01-01

    Full Text Available Particle-induced X-ray emission is used for determining the elemental composition of materials. This method uses low-energy protons (of several MeV, which can be obtained from high-energy (of tens MeV accelerators. Instead of manufacturing an accelerator for generating the MeV protons, the use of a PET cyclotron has been suggested for designing the beamline for multipurpose applications, especially for the PIXE experiment, which has a dedicated high-energy (of tens MeV accelerator. The beam properties of the cyclotron were determined at this experimental facility by using an external beamline before transferring the ion beam to the experimental chamber. We measured the beam profile and calculated the emittance using the pepper-pot method. The beam profile was measured as the beam current using a wire scanner, and the emittance was measured as the beam distribution at the beam dump using a radiochromic film. We analyzed the measurement results and are planning to use the results obtained in the simulations of external beamline and aligned beamline components. We will consider energy degradation after computing the beamline simulation. The experimental study focused on measuring the emittance from the cyclotron, and the results of this study are presented in this paper.

  19. Bi-directional Alfv\\'en Cyclotron Instabilities in the Mega-Amp Spherical Tokamak

    CERN Document Server

    Sharapov, S E; Akers, R; Ayed, N Ben; Cecconello, M; Cook, J W C; Cunningham, G; Verwichte, E; Tea, the MAST

    2014-01-01

    Alfv\\'en cyclotron instabilities excited by velocity gradients of energetic beam ions were investigated in MAST experiments with super-Alfv\\'enic NBI over a wide range of toroidal magnetic fields from ~0.34 T to ~0.585 T. In MAST discharges with high magnetic field, a discrete spectrum of modes in the sub-cyclotron frequency range is excited toroidally propagating counter to the beam and plasma current (toroidal mode numbers n < 0).

  20. Radiation safety aspects of the AGOR superconducting cyclotron facility

    NARCIS (Netherlands)

    Beijers, JPM; de Meijer, RJ

    1996-01-01

    This paper describes shielding calculations and skyshine estimates for the new AGOR K=600 superconducting cyclotron facility. Both simple, semi-empirical models and Monte-Carlo simulations were used. The calculations are based on a 200 MeV proton beam incident on a trick aluminum target. Also the

  1. Radiation safety aspects of the AGOR superconducting cyclotron facility

    NARCIS (Netherlands)

    Beijers, JPM; de Meijer, RJ

    1996-01-01

    This paper describes shielding calculations and skyshine estimates for the new AGOR K=600 superconducting cyclotron facility. Both simple, semi-empirical models and Monte-Carlo simulations were used. The calculations are based on a 200 MeV proton beam incident on a trick aluminum target. Also the de

  2. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 35

    Energy Technology Data Exchange (ETDEWEB)

    1986-10-29

    Efforts are reported on the installation and checkout of cyclotron components which had been previously fabricated. Final integration of subsystems and major systems leading to internal beam tests is reported near completion. Progress is reported in relation to control system components, focus and steering magnet design, and rf system testing. (LEW)

  3. A small low energy cyclotron for radioisotope measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bertsche, K.J.

    1989-11-01

    Direct detection of {sup 14}C by accelerator mass spectrometry has proved to be a much more sensitive method for radiocarbon dating than the decay counting method invented earlier by Libby. A small cyclotron (the cyclotrino'') was proposed for direct detection of radiocarbon in 1980. This combined the suppression of background through the use of negative ions, which had been used effectively in tandem accelerators, with the high intrinsic mass resolution of a cyclotron. Development of a small electrostatically-focused cyclotron for use as a mass spectrometer was previously reported but the sensitivity needed for detection of {sup 14}C at natural abundance was not achieved. The major contributions of this work are the integration of a high current external ion source with a small flat-field, electrostatically-focused cyclotron to comprise a system capable of measuring {sup 14}C at natural levels, and the analysis of ion motion in such a cyclotron, including a detailed analysis of phase bunching and its effect on mass resolution. A high current cesium sputter negative ion source generates a beam of carbon ions which is pre-separated with a Wien filter and is transported to the cyclotron via a series of electrostatic lenses. Beam is injected radially into the cyclotron using electrostatic deflectors and an electrostatic mirror. Axial focusing is entirely electrostatic. A microchannel plate detector is used with a phase-grated output. In its present form the system is capable of improving the sensitivity of detecting {sup 14}C in some biomedical experiments by a factor of 10{sup 4}. Modifications are discussed which could bring about an additional factor of 100 in sensitivity, which is important for archaeological and geological applications. Possibilities for measurements of other isotopes, such as {sup 3}H, and {sup 10}Be, and {sup 26}Al, are discussed. 70 refs.

  4. Conceptual Design Study of 13 MeV Proton Cyclotron

    Directory of Open Access Journals (Sweden)

    Silakhuddin

    2012-04-01

    Full Text Available A study to determine the conceptual design of a 13 MeV proton cyclotron for PET (Positron Emission Tomography facility has been carried out. Based on studies on reactions of PET radioisotopes production, reaction cross-sections and some design references, a design of the proton cyclotron is proposed. The design criteria for the main components are decided using empirical and semitheoretical methods, as well as by referring to data regarding cyclotrons for PET production. The empirical method was carried out by using some data from operational experiences of BATAN cyclotron at Serpong, while the semitheoretical method was carried out by using the commonly used equations of cyclotron basic theory. The general layout of components and the main components, namely the ion source, the RF dees, the magnet, and the extractor are discussed. Based on the calculations and on the data used, the cyclotron is designed as a negative ion acceleration cyclotron with internal ion source. The designated proton energy and beam currents are 13 MeV and 50 µA. Its magnetic field is in the relativistic mode with sectors on the pole. The magnetic field intensity at the extraction radius is 12.745 kG and in the innermost radius is 12.571 kG. The magnetic poles consist of four sectors to make adequate space for components placement such as dees, ion source, extractor and beam probe. The dee angle is 430. The dee operates at 78 MHz on the fourth harmonic. A multifoil extractor is chosen to obtain an efficient operation

  5. Transparency of Magnetized Plasma at Cyclotron Frequency

    Energy Technology Data Exchange (ETDEWEB)

    G. Shvets; J.S. Wurtele

    2002-03-14

    Electromagnetic radiation is strongly absorbed by a magnetized plasma if the radiation frequency equals the cyclotron frequency of plasma electrons. It is demonstrated that absorption can be completely canceled in the presence of a magnetostatic field of an undulator or a second radiation beam, resulting in plasma transparency at the cyclotron frequency. This effect is reminiscent of the electromagnetically induced transparency (EIT) of the three-level atomic systems, except that it occurs in a completely classical plasma. Unlike the atomic systems, where all the excited levels required for EIT exist in each atom, this classical EIT requires the excitation of the nonlocal plasma oscillation. The complexity of the plasma system results in an index of refraction at the cyclotron frequency that differs from unity. Lagrangian description was used to elucidate the physics and enable numerical simulation of the plasma transparency and control of group and phase velocity. This control naturally leads to applications for electromagnetic pulse compression in the plasma and electron/ion acceleration.

  6. Status of the NSCL Cyclotron Gas Stopper

    CERN Document Server

    Joshi, N; Brodeur, M; Morrissey, D J; Schwarz, S

    2016-01-01

    A gas-filled reverse cyclotron for the thermalisation of energetic beams is under construction at NSCL/MSU. Rare isotopes produced via projectile fragmentation after in-flight separation will be injected into the device and converted into low-energy beams through buffer gas interactions as they spiral towards the centre of the device. The extracted thermal beams will be used for low energy experiments such as precision mass measurements with traps or laser spectroscopy, and further transport for reacceleration. Detailed calculations have been performed to optimize the magnetic field design as well as the transport and stopping of ions inside the gas. An RF carpet will be used to transport the thermal ions to the axial extraction point. The calculations indicate that the cyclotron gas stopper will be much more efficient for the thermalisation of light and medium mass ions compared to linear gas cells. In this contribution we will discuss simulations of the overall performance and acceptance of machine, the bea...

  7. The physics design of magnet in 14 MeV cyclotron

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The 14 MeV, 400 μA compact cyclotron is under construction at China Institute of Atomic Energy (CIAE). The design of main magnet and the result of beam dynamics in the cyclotron will be described in this paper, including the choice of main parameters of magnet, the method of shimming isochronous field in the compact cyclotron and optimization of the magnetic field in central region. The beam will be accelerated to 14.6 MeV by optimizing the magnet structure.

  8. PHENIX on-line systems

    Energy Technology Data Exchange (ETDEWEB)

    Adler, S.S.; Allen, M.; Alley, G.; Amirikas, R.; Arai, Y.; Awes, T.C.; Barish, K.N.; Barta, F.; Batsouli, S.; Belikov, S.; Bennett, M.J.; Bobrek, M.; Boissevain, J.G.; Boose, S.; Britton, C.; Britton, L.; Bryan, W.L.; Cafferty, M.M.; Carey, T.A.; Chang, W.C.; Chi, C.Y.; Chiu, M.; Cianciolo, V.; Cole, B.A.; Constantin, P.; Cook, K.C.; Cunitz, H.; Desmond, E.J.; Ebisu, K.; Efremenko, Y.V.; El Chenawi, K.; Emery, M.S.; Engo, D.; Ericson, N.; Fields, D.E.; Frank, S.; Frantz, J.E.; Franz, A.; Frawley, A.D.; Fried, J.; Gannon, J.; Gee, T.F.; Gentry, R.; Giannotti, P.; Gustafsson, H.-A.; Haggerty, J.S.; Hahn, S.; Halliwell, J.; Hamagaki, H.; Hansen, A.G.; Hara, H.; Harder, J.; He, X.; Heistermann, F.; Hemmick, T.K.; Hibino, M.; Hill, J.C. E-mail: jhill@iastate.edu; Homma, K.; Jacak, B.V.; Jagadish, U.; Jia, J.; Kajihara, F.; Kametani, S.; Kamyshkov, Y.; Kandasamy, A.; Kang, J.H.; Kapustinsky, J.; Katou, K.; Kelley, M.A.; Kelly, S.; Kikuchi, J.; Kim, S.Y.; Kim, Y.G.; Kistenev, E.; Kotchetkov, D.; Kurita, K.; Lajoie, J.G.; Lenz, M.; Lenz, W.; Li, X.H.; Lin, S.; Liu, M.X.; Markacs, S.; Matathias, F.; Matsumoto, T.; Mead, J.; Mischke, R.E.; Mishra, G.C.; Moore, A.; Muniruzzamann, M.; Musrock, M.; Nagle, J.L.; Nandi, B.K.; Newby, J.; Nystrand, J.; O' Brien, E.; O' Connor, P.; Ohnishi, H.; Oskarsson, A.; Osterman, L.; Oyama, K.; Paffrath, L.; Pancake, C.E.; Pantuev, V.S.; Petridis, A.N.; Pisani, R.P.; Plagge, T.; Plasil, F.; Purschke, M.L.; Rankowitz, S.; Rao, R.; Rau, M.; Read, K.F.; Ryu, S.S.; Sakaguchi, T.; Sato, H.D.; Seto, R.; Shiina, T.; Silvermyr, D.; Simon-Gillo, J.; Simpson, M.; Sippach, W.; Skank, H.D.; Skutnik, S.; Sleege, G.A.; Smith, G.D.; Smith, M.; Stankus, P.W.; Steinberg, P.; Sugitate, T.; Sullivan, J.P.; Taketani, A.; Tamai, M.; Tanaka, Y.; Thomas, W.D.; Todd, R.; Toldo, F.; Turner, G.; Ushiroda, T.; Velkovska, J.; Hecke, H.W. van; Lith, M. van; Villatte, L.; Achen, W. von; Walker, J.W.; Wang, H.Q.; White, S.N.; Wintenberg, A.L.; Witzig, C.; Wood, L.[and others

    2003-03-01

    The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each detector subsystem for the purpose of generating events for physics analysis. Processing of event data begins when the Data Collection Modules (DCM) receive data via fiber-optic links from the FEMs. The DCMs format and zero suppress the data and generate data packets. These packets go to the Event Builders (EvB) that assemble the events in final form. The Level-1 trigger (LVL1) generates a decision for each beam crossing and eliminates uninteresting events. The FEMs carry out all detector processing of the data so that it is delivered to the DCMs using a standard format. The FEMs also provide buffering for LVL1 trigger processing and DCM data collection. This is carried out using an architecture that is pipelined and deadtimeless. All of this is controlled by the Master Timing System (MTS) that distributes the RHIC clocks. A Level-2 trigger (LVL2) gives additional discrimination. A description of the components and operation of the PHENIX On-Line system is given and the solution to a number of electronic infrastructure problems are discussed.

  9. Cyclotrons and positron emitting radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  10. RF control hardware design for CYCIAE-100 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhiguo, E-mail: bitbearAT@hotmail.com; Fu, Xiaoliang; Ji, Bin; Zhao, Zhenlu; Zhang, Tianjue; Li, Pengzhan; Wei, Junyi; Xing, Jiansheng; Wang, Chuan

    2015-11-21

    The Beijing Radioactive Ion-beam Facility project is being constructed by BRIF division of China Institute of Atomic Energy. In this project, a 100 MeV high intensity compact proton cyclotron is built for multiple applications. The first successful beam extraction of CYCIAE-100 cyclotron was done in the middle of 2014. The extracted proton beam energy is 100 MeV and the beam current is more than 20 μA. The RF system of the CYCIAE-100 cyclotron includes two half-wavelength cavities, two 100 kW tetrode amplifiers and power transmission line systems (all above are independent from each other) and two sets of Low Level RF control crates. Each set of LLRF control includes an amplitude control unit, a tuning control unit, a phase control unit, a local Digital Signal Process control unit and an Advanced RISC Machines based EPICS IOC unit. These two identical LLRF control crates share one common reference clock and take advantages of modern digital technologies (e.g. DSP and Direct Digital Synthesizer) to achieve closed loop voltage and phase regulations of the dee-voltage. In the beam commission, the measured dee-voltage stability of RF system is better than 0.1% and phase stability is better than 0.03°. The hardware design of the LLRF system will be reviewed in this paper.

  11. Central region design for a 10 MeV internal ion source cyclotron

    Institute of Scientific and Technical Information of China (English)

    QIN Bin; LIU Kai-Feng; FENG Yi-Zhang; FAN Ming-Wu

    2009-01-01

    Internal ion sources are widely adopted in commercial cyclotrons used for short-life isotopes produc-tion. Without beam manipulation provided by the external beam injection line, the central region of this type of cyclotron is more sensitive and should be carefully designed. A design study and beam dynamics simulation for the central region of a 10 MeV compact cyclotron is presented. The OPERA3D/TOSCA code was used to calculate the electric field from a parameterized three dimensional (3D) central region model. With iterative structure optimizations of the central region, the beam centering and vertical focusing is well controlled, and the RF phase acceptance is around 25° A c++ code for beam simulation in the central region was developed and tested.

  12. Design and Experimental Study of the External H~- Ion Source for a 10 MeV Medical Cyclotron

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    A 10 MeV medical cyclotron has been designed by the BRIF Division at CIAE, for which the H- beam is axially injected to the machine. To satisfy the requirement for the cyclotron with H- ion source, a compact multicusp H- ion source has

  13. Design of RF system for CYCIAE-230 superconducting cyclotron

    Science.gov (United States)

    Yin, Zhiguo; Ji, Bin; Fu, Xiaoliang; Cao, Xuelong; Zhao, Zhenlu; Zhang, Tinajue

    2017-05-01

    The CYCIAE230 is a low-current, compact superconducting cyclotron designed for proton therapy. The Radio Frequency system consists of four RF cavities and applies second harmonic to accelerate beams. The driving power for the cavity system is estimated to be approximately 150 kW. The LLRF controller is a self-made device developed and tested at low power using a small-scale cavity model. In this paper, the resonator systems of an S.C. cyclotron in history are reviewed. Contrary to those RF systems, the cavities of the CYCIAE230 cyclotron connect two opposite dees. Two high-power RF windows are included in the system. Each window carries approximately 75 kW RF power from the driver to the cavities. Thus, the RF system for the CY-CIAE230 cyclotron is operated in driven push-pull mode. The two-way amplifier-coupler-cavity systems are operated with approximately the same amount of RF power but 180° out of phase compared with each other. The design, as well as the technical advantage and limitations of this operating mode, of the CYCIAE230 cyclotron RF system is analyzed.

  14. Design of a two-ion-source (2-IS) beam transport line for the production of multi charged radioactive ion beams

    CERN Document Server

    Banerjee, V; Bandyopadhyay, A; Chattopadhyay, S; Polley, A; Nakagawa, T; Kamigaito, O; Goto, A; Yano, Y

    2000-01-01

    A 'two-ion-source' beam transport line between a surface ionization source and a 6.4 GHz on-line Electron Cyclotron Resonance Ion Source (ECRIS) for the production of multi-charged radioactive ions has been designed. The 1 sup + ions from the surface ionization source are decelerated and focused onto the ECRIS plasma so that they can be efficiently trapped there and further ionized to charge state q>1 sup +. A scheme for stepwise and gradual deceleration of the 1 sup + ion beam consisting of a multi-electrode decelerator and a tuning electrode placed before the ECRIS has been optimized. The beam dynamics calculations show that the 1 sup + beam decelerated to energies of 20-50 eV could be focused to a spot size smaller than the radial dimensions of the ECR plasma zone.

  15. The development of technology for the improvement of cyclotron performance

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Jong Seo; Kim, Y. S.; Ha, J. H.; Lee, M. Y.; Lee, H. S

    1999-05-01

    We show the first-order beam optics theory which is a simplified theory that can be used to carry out the initial design of a cyclotron. Based on this, a computer program has been developed to determine main cyclotron parameters such as number of magnet sectors, sector angle, hill and valley fields, and overall size of the cyclotron etc. We then show the result of two-dimensional magnetic field calculation using POISSON program. By using this program, one can determine magnet yoke geometry and the average magnetic fields etc. Finally, the three-dimensional computer program OPERA-3D had been invoked to determine magnet pole tips (i.e. sector). Validity of the design can be seen by investigating magnetic fields, radial and vertical focusing frequencies as a function of the beam energy. In this report, we show the results of cyclotron magnet design. And we designed 72 MHz RF system and ion source system. We tested RF resonance each coupling methods. We show the result of RF design and prototype operation. Our developed ion source is PIG type. We described our design methods and implementation. We report the result of getting negative hydrogen ion.

  16. EC-5 fifth international workshop on electron cyclotron emission and electron cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Prater, R.; Lohr, J. [eds.

    1985-12-31

    This report contains papers on the following topics: electron cyclotron emission measurements; electron cyclotron emission theory; electron cyclotron heating; gyrotron development; and ECH systems and waveguide development. These paper have been indexed separately elsewhere. (LSP).

  17. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  18. The cyclotron laboratory and the RFQ accelerator in Bern

    Science.gov (United States)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Scampoli, P.; von Bremen, K.; Weber, M.

    2013-07-01

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  19. The cyclotron laboratory and the RFQ accelerator in Bern

    Energy Technology Data Exchange (ETDEWEB)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Weber, M. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland); Scampoli, P. [Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics (LHEP), University of Bern, Sidlerstrasse 5, CH-3012 Bern, Switzerland and Department of Physical Sciences, University Federico II, Via Cintia, I-60126 Napoli (Italy); Bremen, K. von [SWAN Isotopen AG, Inselspital, CH-3010 Bern (Switzerland)

    2013-07-18

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  20. Modern compact accelerators of cyclotron type for medical applications

    Science.gov (United States)

    Smirnov, V.; Vorozhtsov, S.

    2016-09-01

    Ion beam therapy and hadron therapy are types of external beam radiotherapy. Recently, the vast majority of patients have been treated with protons and carbon ions. Typically, the types of accelerators used for therapy were cyclotrons and synchrocyclotrons. It is intuitively clear that a compact facility fits best to a hospital environment intended for particle therapy and medical diagnostics. Another criterion for selection of accelerators to be mentioned in this article is application of superconducting technology to the magnetic system design of the facility. Compact isochronous cyclotrons, which accelerate protons in the energy range 9-30 MeV, have been widely used for production of radionuclides. Energy of 230 MeV has become canonical for all proton therapy accelerators. Similar application of a carbon beam requires ion energy of 430 MeV/u. Due to application of superconducting coils the magnetic field in these machines can reach 4-5 T and even 9 T in some cases. Medical cyclotrons with an ironless or nearly ironless magnetic system that have a number of advantages over the classical accelerators are in the development stage. In this work an attempt is made to describe some conceptual and technical features of modern accelerators under consideration. The emphasis is placed on the magnetic and acceleration systems along with the beam extraction unit, which are very important from the point of view of the facility compactness and compliance with the strict medical requirements.

  1. New Cyclotron Targetry to Enhance F-18 clinical Position Emission Tomography

    Energy Technology Data Exchange (ETDEWEB)

    J. Michael Doster

    2008-12-19

    This project proposes to develop cyclotron targets that produce F-18 for clinical Positron Emission Tomography (PET) at significantly higher rates than that available from current targetry. This production rate of 18F is directly proportional to the beam current. Higher beam currents would result in increased 18F production but would be accompanied by higher heat loads to the target. The beam power available in most commercial cyclotrons exceeds the heat removal capacity of current target technology by a factor of two to four, significantly limiting the production rate of Fluorine-18.

  2. Buncher Power Source Monitoring System of 100 MeV Cyclotron

    Institute of Scientific and Technical Information of China (English)

    WEI; Jun-yi; FU; Xiao-liang; GUO; Juan-juan; ZHANG; Yi-wang; CAO; Xue-long; YIN; Zhi-guo; JI; Bin

    2015-01-01

    The 100MeV cyclotron provides 70-100MeV and 200μA proton beam,which can be used in astrophysics,medical,defense,energy and other fields.Buncher system can enhance the beam intensity and expand the scope of application of the accelerator.Buncher system is one part of the

  3. Extraction and diagnostic systems of the CIME cyclotron for SPIRAL project; Systemes d`ejection et de diagnostics du cyclotron CIME du projet SPIRAL

    Energy Technology Data Exchange (ETDEWEB)

    Bibet, D.; Bourgarel, M.P. [Grand Accelerateur National d`Ions Lourds (GANIL), 14 - Caen (France); Laune, B.; Malard, M.; Mormiche, M.; Serafini, A.; Szott, Ph. [Services Techniques, Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1999-11-01

    The extraction of the CIME cyclotron of the SPIRAL R.I.B. facility is composed of two electrostatic deflectors followed by two magnetostatic channels. For the diagnostics, a radial probe carrying a plastic scintillator for the radioactive beams, has been built, as well as dedicated probes in front of each of the channels. A set of 15 electrostatic pick up probes will enable the phase tuning for the stable beams. All these elements have been built and fully tested at the IPN, prior to there final installation on the CIME cyclotron. (authors) 4 figs.

  4. Lattice design and beam dynamics studies of the high energy beam transport line in the RAON heavy ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hyunchang, E-mail: hcjin@ibs.re.kr; Jang, Ji-Ho; Jang, Hyojae; Jeon, Dong-O

    2015-12-01

    In RAON heavy ion accelerator, beams generated by superconducting electron cyclotron resonance ion source (ECR-IS) or Isotope Separation On-Line (ISOL) system are accelerated by lower energy superconducting linac and high energy superconducting linac. The accelerated beams are used in the high energy experimental hall which includes bio-medical and muon-SR facilities, after passing through the high energy beam transport lines. At the targets of those two facilities, the stable and small beams meeting the requirements rigorously are required in the transverse plane. Therefore the beams must be safely sent to the targets and simultaneously satisfy the two requirements, the achromatic condition and the mid-plane symmetric condition, of the targets. For this reason, the lattice design of the high energy beam transport lines in which the long deflecting sections are included is considered as a significant issue in the RAON accelerator. In this paper, we will describe the calculated beam optics satisfying the conditions and present the result of particle tracking simulations with the designed lattice of the high energy beam transport lines in the RAON accelerator. Also, the orbit distortion caused by the machine imperfections and the orbit correction with correctors will be discussed.

  5. Hospital based superconducting cyclotron for neutron therapy: Medical physics perspective

    Science.gov (United States)

    Yudelev, M.; Burmeister, J.; Blosser, E.; Maughan, R. L.; Kota, C.

    2001-12-01

    The neutron therapy facility at the Gershenson Radiation Oncology Center, Harper University Hospital in Detroit has been operational since September 1991. The d(48.5)+Be beam is produced in a gantry mounted superconducting cyclotron designed and built at the National Superconducting Cyclotron Laboratory (NSCL). Measurements were performed in order to obtain the physical characteristics of the neutron beam and to collect the data necessary for treatment planning. This included profiles of the dose distribution in a water phantom, relative output factors and the design of various beam modifiers, i.e., wedges and tissue compensators. The beam was calibrated in accordance with international protocol for fast neutron dosimetry. Dosimetry and radiobiology intercomparions with three neutron therapy facilities were performed prior to clinical use. The radiation safety program was established in order to monitor and reduce the exposure levels of the personnel. The activation products were identified and the exposure in the treatment room was mapped. A comprehensive quality assurance (QA) program was developed to sustain safe and reliable operation of the unit at treatment standards comparable to those for conventional photon radiation. The program can be divided into three major parts: maintenance of the cyclotron and related hardware; QA of the neutron beam dosimetry and treatment delivery; safety and radiation protection. In addition the neutron beam is used in various non-clinical applications. Among these are the microdosimetric characterization of the beam, the effects of tissue heterogeneity on dose distribution, the development of boron neutron capture enhanced fast neutron therapy and variety of radiobiology experiments.

  6. Cyclotron resonant interactions in cosmic particle accelerators

    CERN Document Server

    Terasawa, T; 10.1007/s11214-012-9878-0

    2012-01-01

    A review is given for cyclotron resonant interactions in space plasmas. After giving a simple formulation for the test particle approach, illustrative examples for resonant interactions are given. It is shown that for obliquely propagating whistler waves, not only fundamental cyclotron resonance, but also other resonances, such as transit-time resonance, anomalous cyclotron resonance, higher-harmonic cyclotron resonance, and even subharmonic resonance can come into play. A few recent topics of cyclotron resonant interactions, such as electron injection in shocks, cyclotron resonant heating of solar wind heavy ions, and relativistic modifications, are also reviewed.

  7. Multimegawatt DAE$\\delta$ALUS Cyclotrons for Neutrino Physics

    CERN Document Server

    Abs, M; Alonso, J R; Barletta, W A; Barlow, R; Calabretta, L; Calanna, A; Campo, D; Celona, L; Conrad, J M; Gammino, S; Kleeven, W; Koeth, T; Maggiore, M; Okuno, H; Piazza, L A C; Seidel, M; Shaevitz, M H; Stingelin, L; Yang, J J; Yeck, J

    2012-01-01

    DAE$\\delta$ALUS (Decay-At-rest Experiment for $\\delta_{CP}$ studies At the Laboratory for Underground Science) provides a new approach to the search for CP violation in the neutrino sector. High-power continuous-wave proton cyclotrons efficiently provide the necessary proton beams with an energy of up to 800 MeV to create neutrinos from pion and muon decay-at-rest. The experiment searches for $\\bar{\

  8. Coaxial Ring Cyclotron as a Perspective Nuclear Power Engineering Machine

    OpenAIRE

    Tumanyan, A. R.; Simonyan, Kh. A.; Mkrtchyan, R. L.; Amatuni, A. Ts.; Avakyan, R. O.; Khudaverdyan, A. G.

    1995-01-01

    The circuit arrangement of the proposed coaxial ring cyclotron (CRC) is described, and its main advantages, such as simple injection technique, several injected beams summation option, high efficiency, are considered. The proposed proton accelerator is a perspective machine for the solution of the main problems of the present day nuclear power engineering as well as for the next-generation nuclear power plants, representing a combination of subcritical reactors and particle accelerators. The ...

  9. Determination of Magnet Specification of 13 MeV Proton Cyclotron Based on Opera 3D

    Directory of Open Access Journals (Sweden)

    Taufik

    2014-08-01

    Full Text Available The magnet is one of the main components of a cyclotron, used to form a circular particle beam trajectories and to provide focusing of the beam. To support the mastery of 13-MeV proton cyclotron technologies, cyclotron magnet design must be done to satisfy cyclotron magnet requirements. This research was conducted by studying important parameters in designing the cyclotron magnet which is then used to determine the design requirements. The magnet design was based on the results of a 3D simulation using Opera 3D software. Opera 3D is a software developed by Cobham plc to solve physical problems in 3D such as magnetostatic using finite element methods. The simulation started by drawing a 3D model of the magnet using a modeler, followed by magnetic field calculations by Tosca module in the Opera 3D software. Simulation results were analyzed with the Genspeo software to determine whether the parameters of the cyclotron magnet have met design requirements. The results indicate that the magnet design satisfied the cyclotron magnet design requirement, that B in the median plane of the magnetic pole approached the isochronous curve, providing axial and radial focusing beam, crossing the resonance line at vr = 1 when the particle energy is low and the particle energy is more than 13 MeV, and lead to small enough phase shift of about 13°. The dimension of the cyclotron magnet is 1.96 m × 1.30 m × 1.21 m; its weight is 17.3 ton; its coil current is 88,024 ampere-turn; its center magnetic field is 1.27479 T; its maximum magnetic field is 1.942116 T; its minimum magnetic field is 0.7689 T; its valley gap is 120 mm; its hill gaps are 40 to 50.78 mm; and its hill angles are 35° to 44°.to 44°

  10. CSIR cyclotron modified for radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    National Accelerator Centre (NAC) staff members will be making an important contribution to radiation therapy in South Africa when the Transvaal Department of Hospital Services starts treating certain types of cancer with fast neutrons, at the Pretoria Cyclotron on the CSIR campus. The fast neutrons will be utilized mainly to treat advanced cancers of the head and the neck. The project will develop along two lines. Firstly the Pretoria cyclotron must be modified and secondly satisfactory radiobiological data must be provided before patients may be treated. This radiobiological experiment heralds a new area for use of the cyclotron which has thus far been used mainly for basic nuclear research and the production of isotopes.

  11. Use of cyclotrons in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Qaim, S.M. E-mail: s.m.qaim@fz-juelich.de

    2004-11-01

    Cyclotrons are versatile ion-accelerating machines which find many applications in medicine. In this short review their use in hadron therapy is briefly discussed. Proton therapy is gaining significance because of its capability to treat deep-lying tumours. A strong area of application of cyclotrons involves the production of short-lived neutron deficient radiotracers for use in emission tomography, especially positron emission tomography. This fast and quantitative in vivo diagnostic technique is being increasingly used in neurology, cardiology and oncology. Besides routine patient care, considerable interdisciplinary work on development of new positron emitters is under way. A short account of those efforts is given. The use of cyclotrons in the production of radionuclides for internal radiotherapy is also briefly described.

  12. Traveling wave ion transport for the cyclotron gas stopper

    Energy Technology Data Exchange (ETDEWEB)

    Brodeur, M., E-mail: maxime.brodeur.2@nd.edu; Joshi, N.; Gehring, A.E.; Bollen, G.; Morrissey, D.J.; Schwarz, S.

    2013-12-15

    Highlights: • Estimated transport time of thermal ions of 5 ms or less for the cyclotron gas stopper using the ion surfing method. • Experimental investigation of a prototype ion conveyor to transport ions in the magnet magnetic field gradient. • Efficient long-distance ion transport with the conveyor is expected. -- Abstract: Next generation beam thermalization devices such as the cyclotron gas stopper are being developed to efficiently deliver a broad range of radioactive isotopes to experiments. Ion transport methods utilizing a traveling wave were investigated experimentally as part of the developments needed for this device. The “ion surfing” method, which will be used to transports thermal ions inside the main chamber of the cyclotron gas stopper, was found to transport ions at speeds reaching 75 m/s, resulting in net transport times as short as 5 ms. A second traveling wave transport method called the “ion conveyor” was investigated for the challenging task of extracting the ions through the cyclotron gas stopper magnetic field gradient. Results from the first prototype conveyor show a strong pressure and wave amplitude dependance for the transport efficiency. A second prototype designed to operate over a larger pressure range is currently being tested.

  13. Digital control in LLRF system for CYCIAE-100 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhiguo, E-mail: bitbearAT@hotmail.com; Fu, Xiaoliang; Ji, Bin; Zhang, Tianjue; Wang, Chuan

    2016-05-21

    As a driven accelerator, the CYCIAE-100 cyclotron is designed by China Institute of Atomic Energy for the Beijing Radio Ion-beam Facility project. The cyclotron RF system is designed to use two RF power sources of 100 kW to drive two half-wavelength cavities respectively. Two Dee accelerating electrodes are kept separately from each other inside the cyclotron, while their accelerating voltages are maintained in phase by the efforts of LLRF control. An analog–digital hybrid LLRF system has been developed to achieve cavity tuning control, dee voltage amplitude and phase stabilization etc. The analog subsystems designs are focused on RF signal up/down conversion, tuning control, and dee voltage regulation. The digital system provides an RF signal source, aligns the cavity phases and maintains a Finite State Machine. The digital parts combine with the analog functions to provide the LLRF control. A brief system hardware introduction will be given in this paper, followed by the review of several major characteristics of the digital control in the 100 MeV cyclotron LLRF system. The commissioning is also introduced, and most of the optimization during the process was done by changing the digital parts.

  14. Digital control in LLRF system for CYCIAE-100 cyclotron

    Science.gov (United States)

    Yin, Zhiguo; Fu, Xiaoliang; Ji, Bin; Zhang, Tianjue; Wang, Chuan

    2016-05-01

    As a driven accelerator, the CYCIAE-100 cyclotron is designed by China Institute of Atomic Energy for the Beijing Radio Ion-beam Facility project. The cyclotron RF system is designed to use two RF power sources of 100 kW to drive two half-wavelength cavities respectively. Two Dee accelerating electrodes are kept separately from each other inside the cyclotron, while their accelerating voltages are maintained in phase by the efforts of LLRF control. An analog-digital hybrid LLRF system has been developed to achieve cavity tuning control, dee voltage amplitude and phase stabilization etc. The analog subsystems designs are focused on RF signal up/down conversion, tuning control, and dee voltage regulation. The digital system provides an RF signal source, aligns the cavity phases and maintains a Finite State Machine. The digital parts combine with the analog functions to provide the LLRF control. A brief system hardware introduction will be given in this paper, followed by the review of several major characteristics of the digital control in the 100 MeV cyclotron LLRF system. The commissioning is also introduced, and most of the optimization during the process was done by changing the digital parts.

  15. Plane gyroklinotron at first and third harmonics of cyclotron frequency

    Energy Technology Data Exchange (ETDEWEB)

    Kurayev, A.A.; Lukashonok, D.V.; Sinitsyn, A.K., E-mail: kurayev@bsuir.by, E-mail: timka86@gmail.com [Belarusian State University of Informatics and Radioelectronics, Minsk (Belarus)

    2011-07-01

    The results of gyroklinotron's parameters optimization for efficiency at f = 100 GHz with interaction on first and third harmonics of the cyclotron frequency are presented. The predicted electron gyroklinotron's efficiency reaches 70% on first harmonic and 40% on third harmonic. This is more than in usual gyrotron. Besides in contrast to usual gyrotron the width electron beam on radius of guiding centers of electron orbits in gyroklinotron may considerable exceed working wave length {lambda}. This allows to use in it considerable more power of electron beams EB then in usual gyrotron. (author)

  16. Calculation of New Beam Dump Shielding for CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The 100 MeV high intensity cyclotron, CYCIAE-100, places a demanding requirement on the collection device to accept the proton beam. According to the original design, the beam dump would be settled in the cyclotron vault. It uses pure aluminum as the target material,

  17. Formación on line On line learning

    Directory of Open Access Journals (Sweden)

    O. Grau-Perejoan

    2008-09-01

    Full Text Available La formación on line es una modalidad de enseñanza a distancia basada en las nuevas tecnologías. En este artículo se pretende hacer una introducción a base de describir a grandes rasgos sus características principales: asincronía, no presencialidad, comunicación escrita, función del profesor on line, así como los retos, los riesgos, las ventajas y los inconvenientes que plantea. Se exponen las diferencias entre la formación on line y la formación presencial, de manera que los docentes puedan adaptar de la mejor manera posible sus propuestas formativas a la modalidad on line. Se introduce el importantísimo papel de la planificación y de la fase de diseño y, finalmente, se repasan conceptos útiles para comprender mejor el mundo de la formación on line como son los conceptos entorno virtual de aprendizaje (EVA o Blended Learning (B-Learning.On line learning is a type of distance education based on new technologies. This article's aim is to introduce its main characteristics -asynchrony, non-presentiality, written communication, e-teacher role- as well as its challenges, risks, advantages and limitations. Differences between on line learning and face-to-face learning are presented in order to enable educational professionals to adapt their courses to the on line methodology. Planning and designing are introduced as key phases and, finally, useful concepts such as Virtual Learning Environment (VLE or Blended Learning (B-Learning are reviewed in order to achieve a better understanding of the on line learning field.

  18. Development of an 18 GHz superconducting electron cyclotron resonance ion source at RCNP.

    Science.gov (United States)

    Yorita, Tetsuhiko; Hatanaka, Kichiji; Fukuda, Mitsuhiro; Kibayashi, Mitsuru; Morinobu, Shunpei; Okamura, Hiroyuki; Tamii, Atsushi

    2008-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source has recently been developed and installed in order to extend the variety and the intensity of ions at the RCNP coupled cyclotron facility. Production of several ions such as O, N, Ar, Kr, etc., is now under development and some of them have already been used for user experiments. For example, highly charged heavy ion beams like (86)Kr(21+,23+) and intense (16)O(5+,6+) and (15)N(6+) ion beams have been provided for experiments. The metal ion from volatile compounds method for boron ions has been developed as well.

  19. Status report on cyclotron operation

    CERN Document Server

    Kovács, P; Ander, I; Lakatos, T; Fenyvesi, A; Ditrói, F; Takács, S; Tarkanyi, F

    2003-01-01

    The operation of the cyclotron in 2002 was concentrated to 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 4084 hours, the breakdown periods amounted to 15 hours last year. In order to improve the circumstances of the irradiations, several following improvements were done. (R.P.)

  20. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  1. Cyclotrons with fast variable and/or multiple energy extraction

    Directory of Open Access Journals (Sweden)

    C. Baumgarten

    2013-10-01

    Full Text Available We discuss the possibility in principle of stripping extraction in combination with reverse bends in isochronous separate-sector cyclotrons (and/or fixed field alternating gradient accelerators. If one uses reverse bends between the sectors (instead of or in combination with drifts and places stripper foils at the sector exit edges, the stripped beam has a reduced bending radius and it should be able to leave the cyclotron within the range of the valley—even if the beam is stripped at less than full energy. We are especially interested in stripping of H_{2}^{+}, as it doubles the charge to mass ratio of the ions. However the method could be applied to other ions or ionized molecules as well. For the production of proton beams by stripping extraction of an H_{2}^{+} beam, we discuss possible designs for three types of machines: First, a low-energy cyclotron for the simultaneous production of several beams at multiple energies—for instance 15, 30, and 70 MeV—thus allowing beam delivery on several isotope production targets. In this case it can be an advantage to have a strong energy dependence of the direction of the extracted beam. Second, we consider a fast variable-energy proton machine for cancer therapy that should allow extraction (of the complete beam at all energies in the range of about 70 MeV to about 250 MeV into the same beam line. Third, we consider a high-intensity high-energy machine, where the main design goals are extraction with low losses, low activation of components, and high reliability. Especially if such a machine is considered for an accelerator driven system (ADS, this extraction mechanism has advantages: Beam trips by the failure of electrostatic elements could be avoided and the turn separation would be less critical, which allows operation at lower main cavity voltages. This would in turn reduce the number of rf trips. The price that has to be paid for these advantages is an increase in size and/or field

  2. Studies of radioisotope production with an AVF cyclotron in TIARA

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, Toshiaki [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    The production of radioisotopes to be used mainly for nuclear medicine and biology is studied with an AVF cyclotron in TIARA. A production method of no-carrier-added {sup 186}Re with the {sup 186}W(p,n){sup 186}Re reaction has been developed; this product may be used as a therapeutic agent in radioimmunotherapy due to the adequate nuclear and chemical properties. For the study of the function of plants using a positron-emitter two-dimensional imaging system, a simple method of producing the positron emitter {sup 18}F in water was developed by taking advantage of a highly-energetic {alpha} beam from the AVF cyclotron. (author)

  3. Preliminary results with a strip ionization chamber used as beam monitor for hadrontherapy treatments

    Science.gov (United States)

    Boriano, A.; Bourhaleb, F.; Cirio, R.; Cirrone, G. A. P.; Cuttone, G.; Donetti, M.; Garelli, E.; Giordanengo, S.; Luparia, A.; Marchette, F.; Peroni, C.; Raffaele, L.; Sabini, M. G.; Valastro, L.

    2006-01-01

    Preliminary results are presented from a test of a parallel plate ionization chamber with the anode segmented in strips (MOPI) to be used as a beam monitor for therapeutical treatments on the 62 MeV proton beam line of the INFN-LNS Superconducting Cyclotron. Ocular pathologies have been treated at the Catana facility since March 2002. The detector, placed downstream of the patient collimator, will allow the measurement of the relevant beam diagnostic parameters during treatment such as integrated beam fluence, for dose determination; the beam baricentre, width and asymmetry will be obtained from the fluence profile sampled with a resolution of about 100 Urn at a rate up to 1 kHz with no dead time. In this test, carried out at LNS, the detector has been exposed to different beam shapes and the integrated fluence derived by the measured beam profiles has been compared with that obtained with other dosimeters normally used for treatment. The skewness of the beam profile has been measured and shown to be suitable to on-line check variations of the beam shape.

  4. Design of an EBIS charge breeder system for rare-isotope beams

    Science.gov (United States)

    Park, Young-Ho; Son, Hyock-Jun; Kim, Jongwon

    2016-09-01

    Rare-isotope beams will be produced by using the isotope separation on-line (ISOL) system at the Rare Isotope Science Project (RISP). A proton cyclotron is the driver accelerator for ISOL targets, and uranium carbide (UCx) will be a major target material. An isotope beam of interest extracted from the target will be ionized and selected by using a mass separator. The beam emittance will then be reduced by using a radio-frequency quadrupole (RFQ) cooler before the beam is injected into the electron-beam ion-source (EBIS) charge breeder (CB). The maximum electron beam current of the EBIS is 3 A from a cathode made of IrCe in an applied magnetic field of 0.2 T. The size of the electron beam is compressed by magnetic fields of up to 6 T caused in the charge-breeding region by a superconducting solenoid. The design of EBIS-CB was performed by using mechanics as well as beam optics. A test stand for the electron gun and its collector, which can take an electron-beam power of 20 kW, are under construction. The gun assembly was first tested by using a high-voltage pulse so as to measure its perveance. The design of the EBIS, along with its test stand, is described.

  5. Vortex Dynamics and Shear-Layer Instability in High-Intensity Cyclotrons

    Science.gov (United States)

    Cerfon, Antoine J.

    2016-04-01

    We show that the space-charge dynamics of high-intensity beams in the plane perpendicular to the magnetic field in cyclotrons is described by the two-dimensional Euler equations for an incompressible fluid. This analogy with fluid dynamics gives a unified and intuitive framework to explain the beam spiraling and beam breakup behavior observed in experiments and in simulations. Specifically, we demonstrate that beam breakup is the result of a classical instability occurring in fluids subject to a sheared flow. We give scaling laws for the instability and predict the nonlinear evolution of beams subject to it. Our work suggests that cyclotrons may be uniquely suited for the experimental study of shear layers and vortex distributions that are not achievable in Penning-Malmberg traps.

  6. Emittance of short-pulsed high-current ion beams formed from the plasma of the electron cyclotron resonance discharge sustained by high-power millimeter-wave gyrotron radiation

    Science.gov (United States)

    Razin, S.; Zorin, V.; Izotov, I.; Sidorov, A.; Skalyga, V.

    2014-02-01

    We present experimental results on measuring the emittance of short-pulsed (≤100 μs) high-current (80-100 mA) ion beams of heavy gases (Nitrogen, Argon) formed from a dense plasma of an ECR source of multiply charged ions (MCI) with quasi-gas-dynamic mode of plasma confinement in a magnetic trap of simple mirror configuration. The discharge was created by a high-power (90 kW) pulsed radiation of a 37.5-GHz gyrotron. The normalized emittance of generated ion beams of 100 mA current was (1.2-1.3) π mm mrad (70% of ions in the beams). Comparing these results with those obtained using a cusp magnetic trap, it was concluded that the structure of the trap magnetic field lines does not exert a decisive influence on the emittance of ion beams in the gas-dynamic ECR source of MCI.

  7. The development of cyclotron radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Dae; Chun, K. W.; Suh, Y. S.; Lee, J. D.; Ahn, S. H. and others

    1999-03-01

    The purpose of this project is to developthe radiopharmaceuticals and automatic synthetic unit for labelled compounds, and to establish mass production system of radiopharmaceuticals. These will contribute to the early diagnosis of the disease hard to cure. The contents of this project are as follows, the development of the radiopharmaceutical for imaging of cancer, the development of automatic synthesizer for the synthesis of radio-pharmaceuticals, the development of hormone derivatives labelled with {sup 12}'3I, the development of the radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for imaging of myocardial metabolism.

  8. On-line phase space measurement with kicker excitation

    Science.gov (United States)

    Dietrich, J.; Maier, R.; Mohos, I.

    1998-12-01

    A new method for on-line phase space measurements with kicker excitation at COSY was developed. The position data were measured using the analog output of two beam position monitors (BPMs) and directly monitored on a digital storage oscilloscope with an external clock (bunch-synchronous sampling). Nonlinear behavior of the proton beam was visible as well as were resonance islands. Typical measurements are presented.

  9. Method and apparatus for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2010-08-17

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber that includes at least a first section that induces a first magnetron effect that increases a cyclotron frequency of an ion and at least a second section that induces a second magnetron effect that decreases the cyclotron frequency of an ion. The cyclotron frequency changes induced by the first and second magnetron effects substantially cancel one another so that an ion traversing the at least first and second sections will experience no net change in cyclotron frequency.

  10. Evaluation of the latent radiation dose from the activated radionuclides in a cyclotron vault

    Science.gov (United States)

    Kim, Hyunduk; Cho, Gyuseong; Kim, Sun A.; Kang, Bo Sun

    2015-02-01

    The production of short-lived radioisotopes for the synthesis of radiopharmaceuticals typically takes advantage of a cyclotron that accelerates a proton beam up to a few tens of MeV. The number of cyclotrons has been continuously increasing since the first operation of the MC-50 for the production of radiopharmaceuticals at the Korea Institute of Radiological & Medical Sciences (KIRAMS) in 1986, and currently 35 cyclotrons are under operation throughout the nation. As the number of operating cyclotrons has increased, concerns about radiation safety for the persons who are working at the facilities and dwelling in the vicinity of the facilities are becoming important issues. Radiation that could emit a time-dependent dose was shown to exist in a cyclotron vault after its shutdown. The calculation of the latent radiation dose rate was performed by using the MCNPX and the FISPACT. The calculated results for the activated long-lived radioisotopes in the concrete wall and the structural components of the cyclotron facility were compared with the measured data that were obtained by using gamma-ray spectroscopy with a HPGe detector.

  11. Ion cyclotron harmonics in the Saturn downward current auroral region

    Science.gov (United States)

    Menietti, J. D.; Schippers, P.; Santolík, O.; Gurnett, D. A.; Crary, F.; Coates, A. J.

    2011-12-01

    Observations of intense upgoing electron beams and diffuse ion beams have been reported during a pass by Cassini in a downward current auroral region, nearby a source region of Saturn kilometric radiation. Using the Cassini Radio and Plasma Wave Science (RPWS) instrument low frequency waveform receiver and the Cassini Plasma Spectrometer Investigation (CAPS) instrument we have been able to identify ion cyclotron harmonic waves associated with the particle beams. These observations indicate similarities with terrestrial auroral emissions, and may be a source of wave-particle interactions. We fit the observed plasma electron distribution with drifting Maxwellians and perform a linear numerical analysis of plasma wave growth. The results are relevant to ion heating and possibly to electron acceleration.

  12. Recent Results on Ion-Cyclotron and Combined Heating of Textor

    NARCIS (Netherlands)

    Koch, R.; Messiaen, A. M.; Ongena, J.; Vannieuwenhove, R.; Van Oost, G.; van Wassenhove, G.; Dumortier, P.; Durodie, F.; Vandenplas, P. E.; Vanesteer, D.; Vervier, M.; Weynants, R. R.; Finken, K.H.; Euringer, H.; Philipps, V.; Samm, U.; Unterberg, B.; Winter, J.; Bertschinger, G.; Esser, H. G.; Fuchs, G.; Giesen, B.; Hintz, E.; Hoenen, F.; Hutteman, P.; Konen, L.; Korten, M.; Koslowski, H. R.; KramerFlecken, A.; Lochter, M.; Mank, G.; Pospieszczyk, A.; Schweer, B.; Soltwisch, H.; Telesca, G.; Uhlemann, R.; Waidmann, G.; Wolf, G. H.; Boedo, J.; Gray, D.; Hillis, D. L.; Oyevaar, T.; Tammen, H. F.; Tanabe, T.; Ueda, Y.

    1995-01-01

    The recent experimental activity in the field of auxiliary heating and related topics on TEXTOR is reviewed. TEXTOR is equipped with up to 4 MW of ion cyclotron heating power and 3.4 MW of neutral beam injection. The combination of the radiating boundary concept with high auxiliary power has

  13. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    2003-01-01

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  14. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  15. Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source.

    Science.gov (United States)

    Yang, Y; Sun, L T; Feng, Y C; Fang, X; Lu, W; Zhang, W H; Cao, Y; Zhang, X Z; Zhao, H W

    2014-08-01

    Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

  16. Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source

    Science.gov (United States)

    Yang, Y.; Sun, L. T.; Feng, Y. C.; Fang, X.; Lu, W.; Zhang, W. H.; Cao, Y.; Zhang, X. Z.; Zhao, H. W.

    2014-08-01

    Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

  17. Predictive ion source control using artificial neural network for RFT-30 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Young Bae, E-mail: ybkong@kaeri.re.kr; Hur, Min Goo; Lee, Eun Je; Park, Jeong Hoon; Park, Yong Dae; Yang, Seung Dae

    2016-01-11

    An RFT-30 cyclotron is a 30 MeV proton accelerator for radioisotope production and fundamental research. The ion source of the RFT-30 cyclotron creates plasma from hydrogen gas and transports an ion beam into the center region of the cyclotron. Ion source control is used to search source parameters for best quality of the ion beam. Ion source control in a real system is a difficult and time consuming task, and the operator should search the source parameters by manipulating the cyclotron directly. In this paper, we propose an artificial neural network based predictive control approach for the RFT-30 ion source. The proposed approach constructs the ion source model by using an artificial neural network and finds the optimized parameters with the simulated annealing algorithm. To analyze the performance of the proposed approach, we evaluated the simulations with the experimental data of the ion source. The performance results show that the proposed approach can provide an efficient way to analyze and control the ion source of the RFT-30 cyclotron.

  18. Beam line design using G4BeamLine

    CERN Document Server

    Dogan, Arda

    2014-01-01

    In Turkey in Ankara TAEK SANAEM Proton Accelerator Facility (PAF), there is a cyclotron which produces a focused intense 30 MeV proton beam and sends this beam to four different arms, three of which uses this beam to produce pharmaceutical medicine. The remaining one is spared for R&D purposes and the idea was to use these protons coming out from the fourth arm to use space radiation tests, which cannot be done in Turkey at the moment. However, according to SCC 25100 standards which is for 30 MeV protons, the beam coming out of cyclotron is too intense and focused to use for space radiation tests. Therefore, the main aim of my project is to design a beam line which will defocus the beam and reduce the flux so that the space radiation tests can be done according to the standards of SCC 25100.

  19. Preliminary Design Study of High-Power H2+ Cyclotrons for the DAEdALUS Experiment

    CERN Document Server

    Calabretta, L; Gammino, S; Rifuggiato, D; Ciavola, G; Maggiore, M; Piazza, L A C; Alonso, J R; Barletta, W A; Calanna, A; Conrad, J M

    2011-01-01

    This report provides a first design for H2+ accelerators as the DAEdALUS neutrino sources. A description of all aspects of the system, from the ion source to the extracted beam, is provided. The analysis provides a first proof of principle of a full cyclotron system which can provide the necessary beam power for the CP violation search proposed by the DAEdALUS Collaboration.

  20. Installation and Test of 100 MeV Cyclotron Safety Interlock System

    Institute of Scientific and Technical Information of China (English)

    HOU; Shi-gang; SONG; Guo-fang; LI; Zhen-guo; WANG; Feng; LV; Yin-long; XING; Jian-sheng; CAI; Hong-ru; YIN; Zhi-guo; WU; Long-cheng; XIE; Huai-dong; GE; Tao; CAO; Lei; FU; Xiao-liang; WEN; Li-peng

    2013-01-01

    The safety system is an important part of BRIF project,which will play a key role for protection of staff,and equipments.100 MeV cyclotron will deliver proton beam of 200μA with energy of 100 MeV.Radiation caused by beam loss will be occurred when the machine running or commissioning,which is hazard to staff and device,so a set of interlock system is designed for protecting people and apparatus.

  1. Compact ultrafast orthogonal acceleration time-of-flight mass spectrometer for on-line gas analysis by electron impact ionization and soft single photon ionization using an electron beam pumped rare gas excimer lamp as VUV-light source.

    Science.gov (United States)

    Mühlberger, F; Saraji-Bozorgzad, M; Gonin, M; Fuhrer, K; Zimmermann, R

    2007-11-01

    Orthogonal acceleration time-of-flight mass spectrometers (oaTOFMS), which are exhibiting a pulsed orthogonal extraction of ion bunches into the TOF mass analyzer from a continuous primary ion beam, are well-suited for continuous ionization methods such as electron impact ionization (EI). Recently an electron beam pumped rare gas excimer lamp (EBEL) was introduced, which emits intensive vacuum UV (VUV) radiation at, e.g., 126 nm (argon excimer) and is well suited as the light source for soft single photon ionization (SPI) of organic molecules. In this paper, a new compact oaTOFMS system which allows switching between SPI, using VUV-light from an EBEL-light source, and conventional EI is described. With the oaTOFMS system, EBEL-SPI and EI mass spectral transients can be recorded at very high repetition rates (up to 100 kHz), enabling high duty cycles and therefore good detection efficiencies. By using a transient recorder card with the capability to perform on-board accumulation of the oaTOF transients, final mass spectra with a dynamic range of 106 can be saved to the hard disk at a rate of 10 Hz. As it is possible to change the ionization modes (EI and SPI) rapidly, a comprehensive monitoring of complex gases with highly dynamic compositions, such as cigarette smoke, is possible. In this context, the EI based mass spectra address the bulk composition (compounds such as water, oxygen, carbon dioxide, etc. in the up to percentage concentration range) as well as some inorganic trace gases such as argon, sulfur dioxide, etc. down to the low ppm level. The EBEL-SPI mass spectra on the other hand are revealing the organic composition down to the lower ppb concentration range.

  2. CERN Video News on line

    CERN Multimedia

    2003-01-01

    The latest CERN video news is on line. In this issue : an interview with the Director General and reports on the new home for the DELPHI barrel and the CERN firemen's spectacular training programme. There's also a vintage video news clip from 1954. See: www.cern.ch/video or Bulletin web page

  3. Microwave emission related to cyclotron instabilities in a minimum-B electron cyclotron resonance ion source plasma

    Science.gov (United States)

    Izotov, I.; Tarvainen, O.; Mansfeld, D.; Skalyga, V.; Koivisto, H.; Kalvas, T.; Komppula, J.; Kronholm, R.; Laulainen, J.

    2015-08-01

    Electron cyclotron resonance ion sources (ECRIS) have been essential in the research and applications of nuclear physics over the past 40 years. They are extensively used in a wide range of large-scale accelerator facilities for the production of highly charged heavy ion beams of stable and radioactive elements. ECRISs are susceptible to kinetic instabilities due to resonance heating mechanism leading to anisotropic electron velocity distribution function. Instabilities of cyclotron type are a proven cause of frequently observed periodic bursts of ‘hot’ electrons and bremsstrahlung, accompanied with emission of microwave radiation and followed by considerable drop of multiply charged ions current. Detailed studies of the microwave radiation associated with the instabilities have been performed with a minimum-B 14 GHz ECRIS operating on helium, oxygen and argon plasmas. It is demonstrated that during the development of cyclotron instability ‘hot’ electrons emit microwaves in sub-microsecond scale bursts at temporally descending frequencies in the 8-15 GHz range with two dominant frequencies of 11.09 and 12.59 GHz regardless of ECRIS settings i.e. magnetic field strength, neutral gas pressure or species and microwave power. The experimental data suggest that the most probable excited plasma wave is a slow extraordinary Z-mode propagating quasi-longitudinally with respect to the external magnetic field.

  4. Cyclotron Line Measurements with INTEGRAL

    Science.gov (United States)

    Pottschmidt, K.; Kreykenbohm, I.; Caballero, I.; Fritz, S.; Schoenherr, G.; Kretschmar, P.; Wilms, J.; McBride, V. A.; Suchy, S.; Rothschild, R. E.

    2008-01-01

    Due to its broadband energy coverage, INTEGRAL has made important contributions to observing and interpreting cyclotron lines, which are present in the 10-100 keV range of a sample of accreting pulsars. In these systems photons with energies fulfilling the resonance condition inelastically Compton scatter off electrons quantized in the accretion column above the neutron star's magnetic pole(s). This process gives rise to the broad, absorption-like lines or 'cyclotron resonant scattering features' (CRSF). The observed lines allow to directly measure the B-fields of these sources, resulting in values of a few times 1E12G. In this overview I will present recent highlights regarding CRSF observations as well as discuss current ideas and models for the physical conditions in the accretion column. Among the former are the stability of the spectrum of Vela X-1 during giant flares in 2003, the observation of three cyclotron lines during the 2004 outburst of V0332+53, the confirmation of the fundamental line at approximately 45 keV during a 2005 normal outburst of A0535-26, and the simultaneous detection of the two lines in the dipping source 4U 1907+09 (for which also a torque reversal was detected for the first time). Through these and other observations it has become increasingly apparent that two types of observations can potentially be used to constrain the accretion column geometry: the determination of energy ratios for multiple harmonic lines (only two sources with greater than 2 lines are known), was well as the evolution of the fundamental line centroid, which, for different sources, may or may not be correlated with flux. Furthermore, first steps have been taken away from the usual phenomenological description of the lines, towards a physical approach based on self-consistent CRSF modeling. Initial applications are presented.

  5. Ion cyclotron waves at Titan

    Science.gov (United States)

    Russell, C. T.; Wei, H. Y.; Cowee, M. M.; Neubauer, F. M.; Dougherty, M. K.

    2016-03-01

    During the interaction of Titan's thick atmosphere with the ambient plasma, it was expected that ion cyclotron waves would be generated by the free energy of the highly anisotropic velocity distribution of the freshly ionized atmospheric particles created in the interaction. However, ion cyclotron waves are rarely observed near Titan, due to the long growth times of waves associated with the major ion species from Titan's ionosphere, such as CH4+ and N2+. In the over 100 Titan flybys obtained by Cassini to date, there are only two wave events, for just a few minutes during T63 flyby and for tens of minutes during T98 flyby. These waves occur near the gyrofrequencies of proton and singly ionized molecular hydrogen. They are left-handed, elliptically polarized, and propagate nearly parallel to the field lines. Hybrid simulations are performed to understand the wave growth under various conditions in the Titan environment. The simulations using the plasma and field conditions during T63 show that pickup protons with densities ranging from 0.01 cm-3 to 0.02 cm-3 and singly ionized molecular hydrogens with densities ranging from 0.015 cm-3 to 0.25 cm-3 can drive ion cyclotron waves with amplitudes of ~0.02 nT and of ~0.04 nT within appropriate growth times at Titan, respectively. Since the T98 waves were seen farther upstream than the T63 waves, it is possible that the instability was stronger and grew faster on T98 than T63.

  6. Cyclotron Line Measurements with INTEGRAL

    Science.gov (United States)

    Pottschmidt, K.; Kreykenbohm, I.; Caballero, I.; Fritz, S.; Schoenherr, G.; Kretschmar, P.; Wilms, J.; McBride, V. A.; Suchy, S.; Rothschild, R. E.

    2008-01-01

    Due to its broadband energy coverage, INTEGRAL has made important contributions to observing and interpreting cyclotron lines, which are present in the 10-100 keV range of a sample of accreting pulsars. In these systems photons with energies fulfilling the resonance condition inelastically Compton scatter off electrons quantized in the accretion column above the neutron star's magnetic pole(s). This process gives rise to the broad, absorption-like lines or 'cyclotron resonant scattering features' (CRSF). The observed lines allow to directly measure the B-fields of these sources, resulting in values of a few times 1E12G. In this overview I will present recent highlights regarding CRSF observations as well as discuss current ideas and models for the physical conditions in the accretion column. Among the former are the stability of the spectrum of Vela X-1 during giant flares in 2003, the observation of three cyclotron lines during the 2004 outburst of V0332+53, the confirmation of the fundamental line at approximately 45 keV during a 2005 normal outburst of A0535-26, and the simultaneous detection of the two lines in the dipping source 4U 1907+09 (for which also a torque reversal was detected for the first time). Through these and other observations it has become increasingly apparent that two types of observations can potentially be used to constrain the accretion column geometry: the determination of energy ratios for multiple harmonic lines (only two sources with greater than 2 lines are known), was well as the evolution of the fundamental line centroid, which, for different sources, may or may not be correlated with flux. Furthermore, first steps have been taken away from the usual phenomenological description of the lines, towards a physical approach based on self-consistent CRSF modeling. Initial applications are presented.

  7. Precise On-line Position Measurement for Particle Therapy

    CERN Document Server

    Actis, O; König, S

    2014-01-01

    An on-line beam position monitoring and regular beam stability tests are of utmost importance for the Quality Assurance (QA) of the patient treatment at any particle therapy facility. The Gantry${0.5 mm}2$ at the Paul Scherrer Institute uses a strip ionization chamber for the on-line beam position verification. The design of the strip chamber placed in the beam in front of the patient allows for a small beam penumbra in order to achieve a high-quality lateral beam delivery. The detector granularity and the low noise allow the reconstruction of the signals offered by Gantry${0.5 mm}2$ with a precision of about 0.1 mm. The frond-end electronics and the whole data processing sequence have been optimized for minimizing the dead time between the beam applications to about 2 ms: the charge collection is performed in about 1 ms, read-out takes place in 100 $\\mu$s while data verification and logging are completed in less than 1 ms. The sub-millimeter precision of the lateral reconstruction allows the dose inhomogenei...

  8. Superconducting cyclotrons at Michigan State University

    Science.gov (United States)

    Blosser, H. G.

    1987-04-01

    This paper describes the status of the three superconducting cyclotrons which are in operation or under construction at the National Superconducting Cyclotron Laboratory. The oldest of these, the K500, has been in operation since September 1982 supporting a national user program in heavy ion nuclear physics. A second large research cyclotron, the K800, is now nearing completion. This cyclotron will accelerate lighter heavy ions to 200 MeV/nuc and heavier particles up to energies given by 1200 Q2/ A MeV/nucleon. The magnet for this cyclotron came into operation in May 1984 and has performed smoothly and reliably in three extended operating periods. At present, K800 construction activity centers on fabrication and installation of the rf system, the extraction system, and the ECR injection line. The third NSCL superconducting cyclotron is a smaller 50 MeV deuteron cyclotron to be used for neutron therapy in the radiation oncology center of a major Detroit hospital (Harper Hospital). Design features of this small, application oriented, cyclotron are described in some detail.

  9. High brightness 50 MeV Cyclotron for Accelerator-Driven Subcritical Fission

    Science.gov (United States)

    Assadi, Saeed; Badgley, Karie; Mann, Thomas; McIntyre, Peter; Pogue, Nathaniel; Sattarov, Akhdiyor

    2011-10-01

    The Accelerator Research Lab at Texas A&M University is developing new accelerator technology for a high-brightness, high-current cyclotron with capabilities that will be beneficial for applications to accelerator-driven subcritical fission, medical isotope production, and proton therapy. As a first embodiment of the technology, we are developing a detailed design for TAMU-50, a 50 MeV, 5 mA proton cyclotron with high beam brightness. In this presentation we present devices and beamline components for injection, extraction, controls and diagnostics. We emphasize the system integration and implementation of TAMU-50 for production of medical radioisotopes.

  10. Kinetic instabilities in pulsed operation mode of a 14 GHz electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O., E-mail: olli.tarvainen@jyu.fi; Kalvas, T.; Koivisto, H.; Komppula, J.; Kronholm, R.; Laulainen, J. [Department of Physics, University of Jyväskylä, 40500 Jyväskylä (Finland); Izotov, I.; Mansfeld, D. [Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Skalyga, V. [Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., 603950 Nizhny Novgorod (Russian Federation)

    2016-02-15

    The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz A-electron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10-100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime.

  11. Developing the smallest possible medical cyclotron

    CERN Multimedia

    Katarina Anthony

    2011-01-01

    Imagine a portable medical cyclotron operated in a conventional radioactive facility at a hospital. Imagine a nurse or technician switching it on and producing isotopes at the patient’s bedside. Sounds like science fiction? Think again.   CERN has teamed up with Spain’s national scientific research centre (CIEMAT) to develop an avant-garde cyclotron to be used for Positron Emission Tomography (PET). “We plan to make a cyclotron that doesn't need an insulated building or ‘vault’: a cyclotron small enough to fit inside a hospital lift,” explains Jose Manuel Perez, who is leading the CIEMAT/CERN collaboration. “It will be the smallest possible medical cyclotron for single patient dose production and will dramatically reduce costs for hospitals.” While PET technology has transformed imaging techniques, many of its medical benefits have remained confined to highly specialised hospitals. “Studies have foun...

  12. Clean Air OnLine

    Energy Technology Data Exchange (ETDEWEB)

    Finney, D. [Environment Canada, Gatineau, PQ (Canada). Air Pollution Prevention Directorate

    2004-04-07

    This presentation describes Clean Air OnLine, a multi-tiered website dedicated to providing Canadians with information on air quality. The website is under development to support action to reduce air emissions, demonstrate the links between air emissions and environmental impacts, and enhance the understanding of sustainable community development issues such as health, energy, and urban sprawl. Partners in the Clean Air OnLine (CAOL) initiative include Environment Canada and the Clean Air Partnership which includes the Greater Toronto Area pilot project. The audience for CAOL includes municipal decision makers, local decision makers, community leaders, and the general public. The project provides Canadians with air pollution contextual information on pollution sources, pollutants, and related issues. It also provides information on health, environmental and economic impacts and the interrelationships with climate change issues and energy use. tabs., figs.

  13. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  14. Electromagnetic waves near the proton cyclotron frequency in the solar wind

    Science.gov (United States)

    Jian, Lan; Alexander, Robert; Wicks, Robert; Stevens, Michael; Figueroa-Vinas, Adolfo; Russell, Christopher

    2015-04-01

    Strong narrow-band electromagnetic waves around the proton cyclotron frequency have been found sporadically in the solar wind throughout the inner heliosphere. They are nearly-circularly polarized and propagate close to the magnetic field. Electromagnetic waves near the proton cyclotron frequency can be ion cyclotron waves or magnetosonic waves. They can play an important role in modulating the solar wind ion distribution, and contribute to the heating and acceleration of solar wind. Since the waves are left-hand or right-hand polarized in the spacecraft frame with similar characteristics, they are probably due to Doppler shift of a same type of waves, or there could be a mixture of waves with intrinsically different polarizations. Through the assistance of audification, we have studied the long-lasting low frequency wave events in 2005 using high-cadence magnetic field data from the Wind mission. The Solar Wind Experiment team of the Wind mission has provided the temperature anisotropies for core protons, beam protons, and alpha particles, as well as the beam drift for selected cases. We conduct wave dispersion analysis using these ion moments to examine if these waves can be explained by ion cyclotron anisotropy instability or ion beam instability related to the solar wind inhomogeneities.

  15. Status report of the Jyvaeskylaeion guide isotope separator on-line facility

    Energy Technology Data Exchange (ETDEWEB)

    Penttilae, H.; Dendooven, P.; Honkanen, A.; Huhta, M.; Jauho, P.P.; Jokinen, A.; Lhersonneau, G.; Oinonen, M.; Parmonen, J.-M.; Peraejaervi, K.; Aeystoe, J. [Jyvaeskylae Univ. (Finland). Dept. of Physics

    1997-04-01

    The ion guide isotope separator facility IGISOL of the University of Jyvaeskylaehas been moved to the new K-130 heavy ion cyclotron laboratory. The totally reconstructed facility is described in detail. The primary beams and targets, helium pumping, separator beam line construction and separator beam diagnostics are discussed. The spectroscopy stations are introduced with illustrative examples from the research program, including beta-delayed proton and neutron spectroscopy, gamma-ray spectroscopy with and without arrays, conversion electron spectroscopy, collinear laser spectroscopy and nuclear level lifetime spectroscopy. (orig.). 15 refs.

  16. Electromagnetic waves near the proton cyclotron frequency: Stereo observations

    Energy Technology Data Exchange (ETDEWEB)

    Jian, L. K. [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Wei, H. Y.; Russell, C. T. [Institute of Geophysics and Planetary Physics, University of California, Los Angeles, CA 90095 (United States); Luhmann, J. G. [Space Science Laboratory, University of California, Berkeley, CA 94720 (United States); Klecker, B. [Max-Planck-Institut für Extraterrestrische Physik, D-85741 Garching (Germany); Omidi, N. [Solana Scientific Inc., Solana Beach, CA 92075 (United States); Isenberg, P. A. [Institute for the Study of Earth, Oceans, and Space, University of New Hampshire, Durham, NH 03824 (United States); Goldstein, M. L.; Figueroa-Viñas, A. [Heliophysics Science Division, NASA Goddard Space Flight Center, MD 20771 (United States); Blanco-Cano, X., E-mail: lan.jian@nasa.gov [Instituto de Geofisica, Universidad Nacional Autónoma de México, Coyoacán D.F. (Mexico)

    2014-05-10

    Transverse, near-circularly polarized, parallel-propagating electromagnetic waves around the proton cyclotron frequency were found sporadically in the solar wind throughout the inner heliosphere. They could play an important role in heating and accelerating the solar wind. These low-frequency waves (LFWs) are intermittent but often occur in prolonged bursts lasting over 10 minutes, named 'LFW storms'. Through a comprehensive survey of them from Solar Terrestrial Relations Observatory A using dynamic spectral wave analysis, we have identified 241 LFW storms in 2008, present 0.9% of the time. They are left-hand (LH) or right-hand (RH) polarized in the spacecraft frame with similar characteristics, probably due to Doppler shift of the same type of waves or waves of intrinsically different polarities. In rare cases, the opposite polarities are observed closely in time or even simultaneously. Having ruled out interplanetary coronal mass ejections, shocks, energetic particles, comets, planets, and interstellar ions as LFW sources, we discuss the remaining generation scenarios: LH ion cyclotron instability driven by greater perpendicular temperature than parallel temperature or by ring-beam distribution, and RH ion fire hose instability driven by inverse temperature anisotropy or by cool ion beams. The investigation of solar wind conditions is compromised by the bias of the one-dimensional Maxwellian fit used for plasma data calibration. However, the LFW storms are preferentially detected in rarefaction regions following fast winds and when the magnetic field is radial. This preference may be related to the ion cyclotron anisotropy instability in fast wind and the minimum in damping along the radial field.

  17. The Cyclotron Production and Nuclear Imaging of BROMINE-77.

    Science.gov (United States)

    Galiano, Eduardo

    In this investigation, bromine-77 was produced with a medical cyclotron and imaged with gamma cameras. Br -77 emits a 240 kev photon with a half life of 56 hours. The C-Br bond is stronger than the C-I bond and bromine is not collected in the thyroid. Bromine can be used to label many organic molecules by methods analogous to radioiodination. The only North American source of Br-77 in the 70's and 80's was Los Alamos National Laboratory, but it discontinued production in 1989. In this method, a p,3n reaction on Br-77 produces Kr-77 which decays with a 1.2 hour half life to Br-77. A cyclotron generated 40 MeV proton beam is incident on a nearly saturated NaBr or LiBr solution contained in a copper or titanium target. A cooling chamber through which helium gas is flowed separates the solution from the cyclotron beam line. Helium gas is also flowed through the solution to extract Kr-77 gas. The mixture flows through a nitrogen trap where Kr-77 freezes and is allowed to decay to Br-77. Eight production runs were performed, three with a copper target and five with a titanium target with yields of 40, 104, 180, 679, 1080, 685, 762 and 118 uCi respectively. Gamma ray spectroscopy has shown the product to be very pure, however corrosion has been a major obstacle, causing the premature retirement of the copper target. Phantom and in-vivo rat nuclear images, and an autoradiograph in a rat are presented. The quality of the nuclear scans is reasonable and the autoradiograph reveals high isotope uptake in the renal parenchyma, a more moderate but uniform uptake in pulmonary and hepatic tissue, and low soft tissue uptake. There is no isotope uptake in the brain or the gastric mucosa.

  18. Production of high intensity {sup 48}Ca for the 88-Inch Cyclotron and other updates

    Energy Technology Data Exchange (ETDEWEB)

    Benitez, J. Y.; Hodgkinson, A.; Lyneis, C. M., E-mail: jybenitez@lbl.gov; Strohmeier, M.; Thullier, T.; Todd, D.; Xie, D. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Franzen, K. Y. [Mevion Medical Systems, 300 Foster St., Littleton, Massachusetts 01460 (United States)

    2014-02-15

    Recently the Versatile ECR for NUclear Science (VENUS) ion source was engaged in a 60-day long campaign to deliver high intensity {sup 48}Ca{sup 11+} beam to the 88-Inch Cyclotron. As the first long term use of VENUS for multi-week heavy-element research, new methods were developed to maximize oven to target efficiency. First, the tuning parameters of VENUS for injection into the cyclotron proved to be very different than those used to tune VENUS for maximum beam output of the desired charge state immediately following its bending magnet. Second, helium with no oxygen support gas was used to maximize the efficiency. The performance of VENUS and its low temperature oven used to produce the stable requested 75 eμA of {sup 48}Ca{sup 11+} beam current was impressive. The consumption of {sup 48}Ca in VENUS using the low temperature oven was checked roughly weekly, and was found to be on average 0.27 mg/h with an ionization efficiency into the 11+ charge state of 5.0%. No degradation in performance was noted over time. In addition, with the successful operation of VENUS the 88-Inch cyclotron was able to extract a record 2 pμA of {sup 48}Ca{sup 11+}, with a VENUS output beam current of 219 eμA. The paper describes the characteristics of the VENUS tune used for maximum transport efficiency into the cyclotron as well as ongoing efforts to improve the transport efficiency from VENUS into the cyclotron. In addition, we briefly present details regarding the recent successful repair of the cryostat vacuum system.

  19. Production of high intensity 48Ca for the 88-Inch Cyclotron and other updates

    Science.gov (United States)

    Benitez, J. Y.; Franzen, K. Y.; Hodgkinson, A.; Lyneis, C. M.; Strohmeier, M.; Thullier, T.; Todd, D.; Xie, D.

    2014-02-01

    Recently the Versatile ECR for NUclear Science (VENUS) ion source was engaged in a 60-day long campaign to deliver high intensity 48Ca11+ beam to the 88-Inch Cyclotron. As the first long term use of VENUS for multi-week heavy-element research, new methods were developed to maximize oven to target efficiency. First, the tuning parameters of VENUS for injection into the cyclotron proved to be very different than those used to tune VENUS for maximum beam output of the desired charge state immediately following its bending magnet. Second, helium with no oxygen support gas was used to maximize the efficiency. The performance of VENUS and its low temperature oven used to produce the stable requested 75 eμA of 48Ca11+ beam current was impressive. The consumption of 48Ca in VENUS using the low temperature oven was checked roughly weekly, and was found to be on average 0.27 mg/h with an ionization efficiency into the 11+ charge state of 5.0%. No degradation in performance was noted over time. In addition, with the successful operation of VENUS the 88-Inch cyclotron was able to extract a record 2 pμA of 48Ca11+, with a VENUS output beam current of 219 eμA. The paper describes the characteristics of the VENUS tune used for maximum transport efficiency into the cyclotron as well as ongoing efforts to improve the transport efficiency from VENUS into the cyclotron. In addition, we briefly present details regarding the recent successful repair of the cryostat vacuum system.

  20. Design study of an ultra-compact superconducting cyclotron for isotope production

    Science.gov (United States)

    Smirnov, V.; Vorozhtsov, S.; Vincent, J.

    2014-11-01

    A 12.5 MeV, 25 μA, proton compact superconducting cyclotron for medical isotope production has been designed and is currently in fabrication. The machine is initially aimed at producing 13N ammonia for Positron Emission Tomography (PET) cardiology applications. With an ultra-compact size and cost-effective price point, this system will offer clinicians unprecedented access to the preferred radiopharmaceutical isotope for cardiac PET imaging. A systems approach that carefully balanced the subsystem requirements coupled to precise beam dynamics calculations was followed. The system is designed to irradiate a liquid target internal to the cyclotron and to minimize the need for radiation shielding. The main parameters of the cyclotron, its design, and principal steps of the development work are presented here.

  1. Results of RIKEN superconducting electron cyclotron resonance ion source with 28 GHz.

    Science.gov (United States)

    Higurashi, Y; Ohnishi, J; Nakagawa, T; Haba, H; Tamura, M; Aihara, T; Fujimaki, M; Komiyama, M; Uchiyama, A; Kamigaito, O

    2012-02-01

    We measured the beam intensity of highly charged heavy ions and x-ray heat load for RIKEN superconducting electron cyclotron resonance ion source with 28 GHz microwaves under the various conditions. The beam intensity of Xe(20+) became maximum at B(min) ∼ 0.65 T, which was ∼65% of the magnetic field strength of electron cyclotron resonance (B(ECR)) for 28 GHz microwaves. We observed that the heat load of x-ray increased with decreasing gas pressure and field gradient at resonance zone. It seems that the beam intensity of highly charged heavy ions with 28 GHz is higher than that with 18 GHz at same RF power.

  2. Accelerator Science and Technology in Canada -- From the Microtron to TRIUMF, Superconducting Cyclotrons and the Canadian Light Source

    Science.gov (United States)

    Craddock, M. K.; Laxdal, R. E.

    As elsewhere, accelerators in Canada have evolved from modest beginnings to major facilities such as TRIUMF (currently with the highest-power driver for rare isotope beam production) and the third generation Canadian Light Source. Highlights along the way include construction of the first microtron, the first racetrack microtron and the first superconducting cyclotron (to which list might have been added the first pulse stretcher ring, had it been funded sooner). This article will summarize the history of accelerators in Canada, documenting both the successes and the near-misses. Besides the research accelerators, a thriving commercial sector has developed, manufacturing small cyclotrons and linacs, beam line components and superconducting rf cavities.

  3. Accelerator Science and Technology in Canada — From the Microtron to TRIUMF, Superconducting Cyclotrons and the Canadian Light Source

    Science.gov (United States)

    Craddock, M. K.; Laxdal, R. E.

    As elsewhere, accelerators in Canada have evolved from modest beginnings to major facilities such as TRIUMF (currently with the highest-power driver for rare isotope beam production) and the third generation Canadian Light Source. Highlights along the way include construction of the first microtron, the first racetrack microtron and the first superconducting cyclotron (to which list might have been added the first pulse stretcher ring, had it been funded sooner). This article will summarize the history of accelerators in Canada, documenting both the successes and the near-misses. Besides the research accelerators, a thriving commercial sector has developed, manufacturing small cyclotrons and linacs, beam line components and superconducting rf cavities.

  4. BEARS: Radioactive ion beams at LBNL

    Energy Technology Data Exchange (ETDEWEB)

    Powell, J.; Guo, F.Q. [Lawrence Berkeley National Lab., CA (United States); Haustein, P.E. [Brookhaven National Lab., Upton, NY (United States). Chemistry Dept.] [and others

    1998-07-01

    BEARS (Berkeley Experiments with Accelerated Radioactive Species) is an initiative to develop a radioactive ion-beam capability at Lawrence Berkeley National Laboratory. The aim is to produce isotopes at an existing medical cyclotron and to accelerate them at the 88 inch Cyclotron. To overcome the 300-meter physical separation of these two accelerators, a carrier-gas transport system will be used. At the terminus of the capillary, the carrier gas will be separated and the isotopes will be injected into the 88 inch Cyclotron`s Electron Cyclotron Resonance (ECR) ion source. The first radioactive beams to be developed will include 20-min {sup 11}C and 70-sec {sup 14}O, produced by (p,n) and (p,{alpha}) reactions on low-Z targets. A test program is currently being conducted at the 88 inch Cyclotron to develop the parts of the BEARS system. Preliminary results of these tests lead to projections of initial {sup 11}C beams of up to 2.5 {times} 10{sup 7} ions/sec and {sup 14}O beams of 3 {times} 10{sup 5} ions/sec.

  5. Cyclotron resonance absorption in ionospheric plasma

    Science.gov (United States)

    Villalon, Elena

    1991-04-01

    The mode conversion of ordinary polarized electromagnetic waves into electrostatic cyclotron waves in the inhomogeneous ionospheric plasma is investigated. Near resonance the warm plasma dispersion relation is a function of the angle theta between the geomagnetic field and the density gradient and of the wave frequency omega, which lies between the electron cyclotron frequency and its doubling. The differential equations describing the electric field amplitudes near the plasma resonance are studied, including damping at the second gyroharmonic. The energy transmission coefficients and power absorbed by the cyclotron waves are calculated. The vertical penetration of the plasma wave amplitudes is estimated using a WKB analysis of the wave equation.

  6. Performance optimization of H(-) multicusp ion source for KIRAMS-30 cyclotron.

    Science.gov (United States)

    Kang, Kun Uk; An, Dong Hyun; Chang, Hong Suk; Chai, Jong Seo

    2008-02-01

    KIRAMS-30 cyclotron has been developed and implemented for radio isotope production. For the purpose of producing negative hydrogen ions and low energy beam injection to the central region of KIRAMS-30, 10 mA H(-) multicusp ion source with beam kinetic energies in the 20-30 keV range and the normalized 4 rms emittance less than 1 mm mrad was installed. The optimized ion source operating condition is presented and the correlation between the extracted beam current and ion source parameters is described for the performance enhancement of the ion source.

  7. A preliminary study of the electron cyclotron resonance ion source for the RAON injector

    Science.gov (United States)

    Hong, I. S.; Kim, Y.; Choi, S. J.; Heo, J. I.; Jin, H. C.; Park, B. S.

    2016-09-01

    We have built and tested an electron cyclotron resonance (ECR) ion source for the Rare Isotope Accelerator of Newness (RAON) injector. Fully superconducting magnets were developed for the ECR ion source. First, an oxygen plasma was ignited, and a preliminary highly-charged oxygen beam was extracted. Next, a 100 μA beam current of oxygen 5+ was extracted when a 1 kW microwave power was injected using a 28 GHz gyrotron. Finally, an off-site test facility was proposed to test the components of the injector by using heavy-ion beams generated by the ECR ion source.

  8. Transmission improvement options via local energy degradation at a cyclotron driven ocular tumor treatment facility

    Science.gov (United States)

    Gerbershagen, Alexander; Hrbacek, Jan; Ijpes, Dennis; Schippers, Jacobus Maarten

    2017-06-01

    The goal of this work is to increase the beam transmission from the cyclotron to the patient location of ocular tumor treatment facility Optis 2 at the Paul Scherrer Institute and thus to reduce the patient treatment times. The examined options for such transmission increase were the installation of local degraders in the patient treatment room and modification of the energy selection collimator settings. The experiments have shown that an improvement of the beam transmission is possible to achieve, however on a cost of an increase in lateral or distal penumbra of the beam. The benefits and drawbacks of the examined options are discussed.

  9. General Electric PETtrace cyclotron as a neutron source for boron neutron capture therapy

    Science.gov (United States)

    Bosko, Andrey

    This research investigates the use of a PETtrace cyclotron produced by General Electric (GE) as a neutron source for boron neutron capture therapy (BNCT). The GE PETtrace was chosen for this investigation because this type of cyclotron is popular among nuclear pharmacies and clinics in many countries; it is compact and reliable; it produces protons with energies high enough to produce neutrons with appropriate energy and fluence rate for BNCT and it does not require significant changes in design to provide neutrons. In particular, the standard PETtrace 18O target is considered. The cyclotron efficiency may be significantly increased if unused neutrons produced during radioisotopes production could be utilized for other medical modalities such as BNCT at the same time. The resulting dose from the radiation emitted from the target is evaluated using the Monte Carlo radiation transport code MCNP at several depths in a brain phantom for different scattering geometries. Four different moderating materials of various thicknesses were considered: light water, carbon, heavy water, arid Fluental(TM). The fluence rate tally was used to calculate photon and neutron dose, by applying fluence rate-to-dose conversion factors. Fifteen different geometries were considered and a 30-cm thick heavy water moderator was chosen as the most suitable for BNCT with the GE PETtrace cyclotron. According to the Brookhaven Medical Research Reactor (BMRR) protocol, the maximum dose to the normal brain is set to 12.5 RBEGy, which for the conditions of using a heavy water moderator, assuming a 60 muA beam current, would be reached with a treatment time of 258 min. Results showed that using a PETtrace cyclotron in this configuration provides a therapeutic ratio of about 2.4 for depths up to 4 cm inside a brain phantom. Further increase of beam current proposed by GE should significantly improve the beam quality or the treatment time and allow treating tumors at greater depths.

  10. Design study of a 9 MeV compact cyclotron system for PET

    Science.gov (United States)

    Lee, Byeong-No; Shin, Seung-Wook; Song, Hoseung; Kim, Hyun-Wook; Chai, Jong-Seo

    2013-06-01

    A cyclotron is an accelerator which can be applied to both cancer diagnosis and treatment. Among commercially sold cyclotrons, the major energy is used for positron emission tomography (PET) ranges from 10 to 20 MeV. In this research, 9 MeV compact cyclotron for PET was designed. The research was conducted on the response cross section and the yield for the energy distribution to decide the design features. Also, it was determined the specifications on the basis of the fluoro-deoxy-glucose (FDG) maximum dose. The machine, which has a 20 uA beam current, is designed to be installed in small-to-medium-sized hospitals in local cities because of its relatively light weight (6 tons). This compact cyclotron, which provides 9-MeV proton beams, is composed of a azimuthally varying field (AVF) electromagnet, 83-MHz RF systems with a 20 kW amplifier, a panning ion gauge (PIG) type ion-source for negative hydrogen, and a double-stage high-vacuum system. The basic model design was done by using 3-D CAD program, CATIA and all the field calculations were performed using commercial electromagnetic field analysis code, OPERA-3D TOSCA. From this research, we expect a time reduction for FDG production, a decrease of radioactive exposure for workers, and an equipment cost reduction.

  11. Electron cyclotron heating and current drive

    NARCIS (Netherlands)

    Westerhof, E.

    1996-01-01

    Plasma heating and non-inductive current drive by waves in the electron cyclotron range of frequencies are reviewed. Both theoretical aspects concerning wave properties, heating and current drive mechanisms, as well as the major experimental results are summarized.

  12. Method and apparatuses for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  13. Building 211 cyclotron characterization survey report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-30

    The Building 211 Cyclotron Characterization Survey includes an assessment of the radioactive and chemical inventory of materials stored within the facility; an evaluation of the relative distribution of accelerator-produced activation products within various cyclotron components and adjacent structures; measurement of the radiation fields throughout the facility; measurement and assessment of internal and external radioactive surface contamination on various equipment, facility structures, and air-handling systems; and an assessment of lead (Pb) paint and asbestos hazards within the facility.

  14. Wave Beam Propagation Through Density Fluctuations

    NARCIS (Netherlands)

    Balakin, A. A.; Bertelli, N.; Westerhof, E.

    2011-01-01

    Perturbations induced by edge density fluctuations on electron cyclotron wave beams propagating in fusion plasmas are studied by means of a quasi-optical code. The effects of such fluctuations are illustrated here by showing the beam propagation in the case of single harmonic perturbations to the wa

  15. The NSCL cyclotron gas stopper – Entering commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, S. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Bollen, G. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); Facility for Rare Isotope Beams, East Lansing, MI (United States); Chouhan, S. [Facility for Rare Isotope Beams, East Lansing, MI (United States); Das, J.J. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Green, M. [Facility for Rare Isotope Beams, East Lansing, MI (United States); Magsig, C. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Morrissey, D.J. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Department of Chemistry, Michigan State University, East Lansing, MI 48824 (United States); Ottarson, J.; Sumithrarachchi, C. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Villari, A.C.C.; Zeller, A. [Facility for Rare Isotope Beams, East Lansing, MI (United States)

    2016-06-01

    Linear gas stopping cells have been used successfully at NSCL to slow down ions produced by projectile fragmentation from the 100 MeV/u to the keV energy range. These ‘stopped beams’ have first been used for low-energy high precision experiments and more recently for NSCLs re-accelerator ReA. A gas-filled reverse cyclotron is currently under construction by the NSCL to complement the existing stopping cells: Due to its extended stopping length, efficient stopping and fast extraction is expected even for light and medium-mass ions, which are difficult to thermalize in linear gas cells. The device is based on a 2.6 T maximum-field cyclotron-type magnet to confine the injected beam while it is slowed down in ≈100 mbar of LN{sub 2}-temperature helium gas. Once thermalized, the beam will be transported to the center of the device by a traveling-wave RF-carpet system, extracted along the symmetry axis with an ion conveyor and miniature RF-carpets, and accelerated to a few tens of keV of energy for delivery to the users. The superconducting magnet has been constructed on a 60 kV platform and energized to its nominal field strength. The magnet’s two cryostats use 3 cryo-refrigerators each and liquid-nitrogen cooled thermal shields to cool the coil pair to superconductivity. This concept, chosen not to have to rely on external liquid helium, has been working well. Measurements of axial and radial field profiles confirm the field calculations. The individual RF-ion guiding components for low-energy ion transport through the device have been tested successfully. The beam stopping chamber with its 0.9 m-diameter RF carpet system and the ion extraction system are being prepared for installation inside the magnet for low-energy ion transport tests.

  16. On-line charge breeding using ECRIS and EBIS

    Science.gov (United States)

    Vondrasek, Richard

    2016-06-01

    The efficient and rapid production of a high-quality, pure beam of highly charged ions is at the heart of any radioactive ion beam facility. Whether an electron cyclotron resonance (ECR) ion source or an electron beam ion source (EBIS) is used to produce these highly charged ions, their operating characteristics will set the boundaries on the range of experiments which can be performed. In addition, time structure and duty cycle have to be considered when defining the operating parameters of the accelerator system as a whole. At Argonne National Laboratory (ANL), an ECR charge breeder was developed as part of the Californium Rare Ion Breeder Upgrade (CARIBU) program. The charge breeding efficiency and high charge state production of the source is at the forefront of ECR charge breeders, but its overall performance as part of the accelerator system is limited by pervasive background and relatively long breeding times. As such, an EBIS charge breeder has been developed and is running in an off-line configuration. It has already demonstrated good breeding efficiencies, shorter residence times, and reduced background and is scheduled to replace the ECR charge breeder in late 2015. The resultant change in duty cycle and time structure necessitates changes to the overall operation of the facility. The experiences with these breeders, as well as from several other facilities which already utilize an ECR or EBIS for charge breeding, help to define the operational characteristics of each technology - their strengths, their weaknesses, and the possible paths to improvement.

  17. RIKEN RI Beam Factory project

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Yasushige; Goto, Akira; Katayama, Takeshi [Institute of Physical and Chemical Research, Wako, Saitama (Japan)

    1997-03-01

    The RARF proposes `RIKEN RI Beam Factory` as a next facility-expanding project. The factory makes it the primary aim to provide RI (Radioactive Isotope) beams covering over the whole atomic-mass range with the world-highest intensity in a wide energy range up to several hundreds MeV/nucleon. These RI beams are generated by the fragmentation of high-intensity heavy-ion beams. For the efficient production heavy-ion energies will be boosted up to over 100 MeV/nucleon even for very heavy ions by a K2500-MeV superconducting ring cyclotron serving as a post accelerator of the existing K540-MeV ring cyclotron. A new type of experimental installation called `MUSES` (Multi-USe Experimental Storage rings) will be constructed as well. With MUSES, various types of unique colliding experiments will become possible. (author)

  18. Initial experience with an 11 MeV self-shielded medical cyclotron on operation and radiation safety

    Directory of Open Access Journals (Sweden)

    Pant G

    2007-01-01

    Full Text Available A self-shielded medical cyclotron (11 MeV was commissioned at our center, to produce positron emitters, namely, 18 F, 15 O, 13 N and 11 C for positron emission tomography (PET imaging. Presently the cyclotron has been exclusively used for the production of 18 F - for 18 F-FDG imaging. The operational parameters which influence the yield of 18 F - production were monitored. The radiation levels in the cyclotron and radiochemistry laboratory were also monitored to assess the radiation safety status in the facility. The target material, 18 O water, is bombarded with proton beam from the cyclotron to produce 18 F - ion that is used for the synthesis of 18 F-FDG. The operational parameters which influence the yield of 18 F - were observed during 292 production runs out of a total of more than 400 runs. The radiation dose levels were also measured in the facility at various locations during cyclotron production runs and in the radiochemistry laboratory during 18 F-FDG syntheses. It was observed that rinsing the target after delivery increased the number of production runs in a given target, as well as resulted in a better correlation between the duration of bombardment and the end of bombardment 18 F - activity with absolutely clean target after being rebuilt. The radiation levels in the cyclotron and radiochemistry laboratory were observed to be well within prescribed limits with safe work practice.

  19. Design of the ion cyclotron system for TPX

    Energy Technology Data Exchange (ETDEWEB)

    Swain, D.; Shipley, S.; Yugo, J.; Goulding, R.; Batchelor, D.; Stallings, D. [Oak Ridge National Lab., TN (United States); Fredd, E. [Princeton Univ., NJ (United States). Plasma Physics Lab.

    1993-06-01

    The TPX experiment will operate for very long pulse times ({ge} 1000 s) and will require current drive of several different types to explore the advanced physics operating modes as one of its main missions. Fast wave current drive (FWCD) using ion cyclotron waves in the 40--80 MHz range will be used as one of the main current-drive mechanisms. For initial operation, 8 MW of rf will be supplied, along with 8 MW of neutral beams and 1.5 MW of lower hybrid power. The ion cyclotron (IC) system is a major part of the TPX heating and current drive system. The IC system must: supply 8 MW of power through two main horizontal ports; be upgradable to provide up to 12 MW of rf power through two ports; operate, for 1000-s pulses every 75 min; drive current using FWCD with high reliability; be bakeable to 350{degree}C for cleaning; and incorporate shielding to attenuate the neutron and gamma flux from DD operation so that hands-on maintenance can be performed exterior to the vacuum vessel. The system will consist of four modified FMIT power units that will be upgraded to deliver 2 MW each to the plasma. Two antennas, each with six current straps, will be located in adjacent ports. A sophisticated matching system is needed to provide experimental flexibility and reliability.

  20. Design of the ion cyclotron system for TPX

    Energy Technology Data Exchange (ETDEWEB)

    Swain, D.; Shipley, S.; Yugo, J.; Goulding, R.; Batchelor, D.; Stallings, D. (Oak Ridge National Lab., TN (United States)); Fredd, E. (Princeton Univ., NJ (United States). Plasma Physics Lab.)

    1993-01-01

    The TPX experiment will operate for very long pulse times ([ge] 1000 s) and will require current drive of several different types to explore the advanced physics operating modes as one of its main missions. Fast wave current drive (FWCD) using ion cyclotron waves in the 40--80 MHz range will be used as one of the main current-drive mechanisms. For initial operation, 8 MW of rf will be supplied, along with 8 MW of neutral beams and 1.5 MW of lower hybrid power. The ion cyclotron (IC) system is a major part of the TPX heating and current drive system. The IC system must: supply 8 MW of power through two main horizontal ports; be upgradable to provide up to 12 MW of rf power through two ports; operate, for 1000-s pulses every 75 min; drive current using FWCD with high reliability; be bakeable to 350[degree]C for cleaning; and incorporate shielding to attenuate the neutron and gamma flux from DD operation so that hands-on maintenance can be performed exterior to the vacuum vessel. The system will consist of four modified FMIT power units that will be upgraded to deliver 2 MW each to the plasma. Two antennas, each with six current straps, will be located in adjacent ports. A sophisticated matching system is needed to provide experimental flexibility and reliability.

  1. PREFACE: Physics with Reaccelerated ISOL Beams Physics with Reaccelerated ISOL Beams

    Science.gov (United States)

    Orr, Nigel

    2010-02-01

    Since the pioneering work of Cockcroft and Walton, one of the central tools in experimental nuclear physics has been reactions induced by accelerated beams. Over the last 25 years or so, following the experiments at Berkeley and elsewhere which saw the uncovering of evidence for the neutron halo, reactions induced by high-energy beams (gtrsim 30 MeV/nucleon) of radioactive nuclei produced via in-flight fragmentation have become an essential probe of nuclei far from stability. Radioactive ions have, however, long been available at very low energies, through the Isotope Separation On-Line (ISOL) method. Indeed, the technique may be traced back as far as the work of Kofoed-Hansen and Nielsen in Copenhagen in the early 1950s. The first, and longest running dedicated ISOL facility is, of course, ISOLDE at CERN, which first started operation in October 1967. Given the combination of intense beams coupled to thick targets, the ISOL technique has the capability of producing very high yields of nuclei far from stability. Extracting and separating the nuclei of interest from the targets requires, as experience at ISOLDE and elsewhere has shown over the years, a broad range of techniques both in both chemistry and ion-source technology, as well as separation techniques. Nevertheless, the routine production of a broad range of elements and isotopes has become possible over the years. Many nuclear reaction studies require beams with energies considerably lower than those produced by in-flight fragmentation, and often with superior optical qualities and much smaller energy spreads (ideally with the characteristics of stable beams). Such needs have lead to the development of (re)accelerated ISOL beams, whereby the on-line target-ion source systems and separators are coupled to a post-accelerator. The first such facility was developed at the Cyclotron Research Centre at Louvain-la-Neuve in the late 1980s based on the existing Cyclone-110 accelerator. Whilst originally

  2. Design, fabrication, and beam commissioning of a continuous-wave four-rod rf quadrupole

    Science.gov (United States)

    Yin, X. J.; Yuan, Y. J.; Xia, J. W.; He, Y.; Zhao, H. W.; Zhang, X. H.; Du, H.; Li, Z. S.; Li, X. N.; Jiang, P. Y.; Yang, Y. Q.; Ma, L. Z.; Wu, J. X.; Xu, Z.; Sun, L. T.; Zhang, W.; Zhang, X. Z.; Meng, J.; Zhou, Z. Z.; Yao, Q. G.; Cai, G. Z.; Lu, W.; Wang, H. N.; Chen, W. J.; Zhang, Y.; Xu, X. W.; Xie, W. J.; Lu, Y. R.; Zhu, K.; Liu, G.; Yan, X. Q.; Gao, S. L.; Wang, Z.; Chen, J. E.

    2016-01-01

    A new heavy-ion linac within a continuous-wave (CW) 4-rod radio-frequency quadrupole (RFQ) was designed and constructed as the injector for the separated-sector cyclotron (SSC) at the Heavy Ion Research Facility at Lanzhou (HIRFL). In this paper, we present the development of and the beam commissioning results for the 53.667 MHz CW RFQ. In the beam dynamics design, the transverse phase advance at zero current, σ0 ⊥ , is maintained at a relatively high level compared with the longitudinal phase advance (σ0 ∥ ) to avoid parametric resonance. A quasi-equipartitioning design strategy was applied to control the emittance growth and beam loss. The installation error of the electrodes was checked using a FARO 3D measurement arm during the manufacturing procedure. This method represents a new approach to measuring the position shifts of electrodes in a laboratory environment and provides information regarding the manufacturing quality. The experimental results of rf measurements exhibited general agreement with the simulation results obtained using CST code. During on-line beam testing of the RFQ, two kinds of ion beams (40Ar 8 + and 16O5+ ) were transported and accelerated to 142.8 keV /u , respectively. These results demonstrate that the SSC-Linac has made a significant progress. And the design scheme and technology experiences developed in this work can be applied to other future CW RFQs.

  3. Design, fabrication, and beam commissioning of a continuous-wave four-rod rf quadrupole

    Directory of Open Access Journals (Sweden)

    X. J. Yin

    2016-01-01

    Full Text Available A new heavy-ion linac within a continuous-wave (CW 4-rod radio-frequency quadrupole (RFQ was designed and constructed as the injector for the separated-sector cyclotron (SSC at the Heavy Ion Research Facility at Lanzhou (HIRFL. In this paper, we present the development of and the beam commissioning results for the 53.667 MHz CW RFQ. In the beam dynamics design, the transverse phase advance at zero current, σ_{0⊥}, is maintained at a relatively high level compared with the longitudinal phase advance (σ_{0∥} to avoid parametric resonance. A quasi-equipartitioning design strategy was applied to control the emittance growth and beam loss. The installation error of the electrodes was checked using a FARO 3D measurement arm during the manufacturing procedure. This method represents a new approach to measuring the position shifts of electrodes in a laboratory environment and provides information regarding the manufacturing quality. The experimental results of rf measurements exhibited general agreement with the simulation results obtained using CST code. During on-line beam testing of the RFQ, two kinds of ion beams (^{40}Ar^{8+} and ^{16}O^{5+} were transported and accelerated to 142.8  keV/u, respectively. These results demonstrate that the SSC-Linac has made a significant progress. And the design scheme and technology experiences developed in this work can be applied to other future CW RFQs.

  4. On-line control of the nonlinear dynamics for synchrotrons

    Science.gov (United States)

    Bengtsson, J.; Martin, I. P. S.; Rowland, J. H.; Bartolini, R.

    2015-07-01

    We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of "smart sextupole knobs" attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  5. Cyclotron resonance maser experiments in a bifilar helical waveguide

    Science.gov (United States)

    Aharony; Drori; Jerby

    2000-11-01

    Oscillator and amplifier cyclotron-resonance-maser (CRM) experiments in a spiral bifilar waveguide are presented in this paper. The slow-wave CRM device employs a low-energy low-current electron beam (2-12 keV, approximately 0.5 A). The pitch angle of the helical waveguide is relatively small; hence, the phase velocity in this waveguide, V(ph) congruent with0.8c (where c is the speed of light), is much faster than the axial velocity of the electrons, V(ez)traveling-wave-tube-type interactions are eliminated in this device. According to the CRM theory, the dominant effect in this operating regime, V(ez)2%). The wide tunable range of this CRM device due to the nondispersive bifilar helix is discussed.

  6. Short-time change of heavy-ion microbeams with different mass to charge ratios by scaling method for the JAEA AVF cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kurashima, Satoshi, E-mail: kurashima.satoshi@jaea.go.jp [Department of Advanced Radiation Technology, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Okumura, Susumu; Miyawaki, Nobumasa; Kashiwagi, Hirotsugu; Satoh, Takahiro; Kamiya, Tomihiro [Department of Advanced Radiation Technology, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Fukuda, Mitsuhiro [Research Center for Nuclear Physics, Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Yokota, Watalu [Department of Advanced Radiation Technology, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2013-07-01

    The JAEA AVF cyclotron provides heavy-ion beams covering a wide range of linear-energy-transfers for microbeam formation. Two types of microbeam formation systems, one using a micro-aperture and the other focusing lenses, are installed on two vertical beam lines of the cyclotron. The average beam time for an experiment using the former system is usually less than 3 h, that is comparable to the time for cyclotron tuning. The time ratio between experiment and tuning determines the usage efficiency of the facility. In order to reduce the tuning time, a scaling method has been introduced to change the ion species with various mass to charge ratios (M/Q) in a shorter total time. The principle of the scaling method is to keep the magnetic rigidity of ion beams constant. This requirement is easily achieved by adjusting the extraction voltage of an ion source proportionally to the M/Q in the beam injection line. Although some cyclotron adjustments, other than the magnetic field strength at the extraction radius, are required, the tuning can be completed within 20 min, and no change is basically required in the beam transport line downstream of the cyclotron. Using the scaling method, 255 MeV {sup 20}Ne{sup 7+}, 335 MeV {sup 20}Ne{sup 8+}, and 440 MeV {sup 40}Ar{sup 13+} beams were extracted from the cyclotron in sequence after the usual tuning of a 220 MeV {sup 12}C{sup 5+}. As a result, we have succeeded in changing the ion species of the heavy-ion microbeam within a total of 30 min.

  7. Fundamental ion cyclotron resonance heating of JET deuterium plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Krasilnikov, A. V. [Troitsk Institute of Nuclear Physics (TRINITI), Russia; Van Eester, D. [Laboratory for Plasma Physics-ERM/KMS (LPP-ERM/KMS), Brussels, Belgium; Lerche, E. [Laboratory for Plasma Physics-ERM/KMS (LPP-ERM/KMS), Brussels, Belgium; Ongena, J. [Laboratory for Plasma Physics-ERM/KMS (LPP-ERM/KMS), Brussels, Belgium; Amosov, V. N. [Troitsk Institute of Nuclear Physics (TRINITI), Russia; Biewer, Theodore M [ORNL; Bonheure, G. [Laboratory for Plasma Physics-ERM/KMS (LPP-ERM/KMS), Brussels, Belgium; Crombe, K. [Ghent University, Belgium; Ericsson, G. [Uppsala University, Uppsala, Sweden; Esposito, Basilio [ENEA, Frascati; Giacomelli, L. [Uppsala University, Uppsala, Sweden; Hellesen, C. [Uppsala University, Uppsala, Sweden; Hjalmarsson, A. [Uppsala University, Uppsala, Sweden; Jachmich, S. [EURATOM / UKAEA, UK; Kallne, J. [Uppsala University, Uppsala, Sweden; Kaschuck, Yu A [Troitsk Institute of Nuclear Physics (TRINITI), Russia; Kiptily, V. [EURATOM / UKAEA, UK; Leggate, H. [EURATOM / UKAEA, UK; Mailloux, J. [EURATOM / UKAEA, UK; Marocco, D. [ENEA, Frascati; Mayoral, M.-L. [EURATOM / UKAEA, UK; Popovichev, S. [EURATOM / UKAEA, UK; Riva, M. [ENEA, Frascati; Santala, M. [EURATOM / UKAEA, UK; Stamp, M. F. [EURATOM / UKAEA, UK; Vdovin, V. [Russian Research Center, Kurchatov Institute, Moscow, Russia; Walden, A. [EURATOM / UKAEA, UK

    2009-03-01

    Radio frequency heating of majority ions is of prime importance for understanding the basic role of auxiliary heating in the activated D T phase of ITER. Majority deuterium ion cyclotron resonance heating (ICRH) experiments at the fundamental cyclotron frequency were performed in JET. In spite of the poor antenna coupling at 25 MHz, this heating scheme proved promising when adopted in combination with D neutral beam injection (NBI). The effect of fundamental ICRH of a D population was clearly demonstrated in these experiments: by adding ~25% of heating power the fusion power was increased up to 30 50%, depending on the type of NBI adopted. At this power level, the ion and electron temperatures increased from Ti ~ 4.0 keV and Te ~ 4.5 keV (NBI-only phase) to Ti ~ 5.5 keV and Te ~ 5.2 keV (ICRH + NBI phase), respectively. The increase in the neutron yield was stronger when 80 keV rather than 130 keV deuterons were injected in the plasma. It is shown that the neutron rate, the diamagnetic energy and the electron as well as the ion temperature scale roughly linearly with the applied RF power. A synergistic effect of the combined use of ICRF and NBI heating was observed: (i) the number of neutron counts measured by the neutron camera during the combined ICRF + NBI phases of the discharges exceeded the sum of the individual counts of the NBI-only and ICRF-only phases; (ii) a substantial increase in the number of slowing-down beam ions was detected by the time of flight neutron spectrometer when ICRF power was switched on; (iii) a small D subpopulation with energies slightly above the NBI launch energy was detected by the neutral particle analyzer and -ray spectroscopy.

  8. Conceptual design of CFETR electron cyclotron wave system

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yunying, E-mail: yytang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, Hefei 230031, Anhui (China); University of Science and Technology of China, Jinzhai Road 96, Hefei 230026, Anhui (China); Wang, Xiaojie; Liu, Fukun; Zhang, Liyuan; Wei, Wei; Xu, Handong; Xu, Weiye; Wu, Dajun; Feng, Jianqiang [Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, Hefei 230031, Anhui (China)

    2015-05-15

    Highlights: • The conceptual design of 170 GHz/20 MW electron cyclotron wave system was introduced. • The layout of RF sources was given. • The design and layout of transmission lines were shown and series of microwave components were introduced. • The structure of launcher was described in detail. • By the optic calculation and optimization of RF propagation inside the launcher, the quasi-optical parameters for launcher design were given. And then temperature distribution and thermal-stress of the injection mirror were analyzed. - Abstract: China Fusion Engineering Test Reactor (CFETR) is a test tokamak which is built for magnetically confined fusion plasma experiments. The electron cyclotron (EC) wave system of CFETR is designed to inject 20 MW RF power into the plasma for heating and current drive (H&CD) applications. The EC wave system consists of RF sources, twenty transmission lines (TLs) and one equatorial launcher. RF sources contain twenty gyrotrons with the output power 1 MW. There are series of microwave components distributed along the TL and the percentage of power losses of each TL is about 8.7%. In the equatorial launcher, five RF beams are injected into one focusing mirror and then reflected to the plasma via one injection mirror. The focusing mirror is spherical to focus Gaussian beam and the injection mirror which is flat can steer in the toroidal direction. After optic calculation and optimization, all the quasi-optical parameters for launcher design are given. Combining with the thermal stress analysis, the chosen inner diameter of water channel of injection mirror is 12 mm and the suggested water velocity is 3 m/s.

  9. Improving cancer treatment with cyclotron produced radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M. Finn, R.D.

    1992-08-04

    This report describes the author's continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program has 3 interactive components: Radiochemistry /Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section under the DOE grant during the 1989--1992 grant period, will be employed in the Pharmacology and Immunology sections of the DOE grant during the 1992--1995 grant period. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  10. Cyclotron resonance absorption in ionospheric plasma

    Energy Technology Data Exchange (ETDEWEB)

    Villalon, E. (Northeastern Univ., Boston, MA (USA) Geophysics Lab., Hanscom AFB, MA (USA))

    1991-04-01

    The mode conversion of ordinary polarized electromagnetic waves into electrostatic cyclotron waves in the inhomogeneous ionospheric plasma is investigated. Near resonance the warm plasma dispersion relation is a function of the angle {theta} between the geomagnetic field and the density gradient and of the wave frequency {omega}, where {Omega} {le} {omega} {le} 2{Omega} and {Omega} is the electron cyclotron frequency. The differential equations describing the electric field amplitudes near the plasma resonance are studied, including damping at the second gyroharmonic. For certain values of {omega} and {theta} (e.g., {theta} < 45{degree}, {omega} {approximately} 2{Omega}) the wave equations reduce to the parabolic cylinder equation. The energy transmission coefficients and power absorbed by the cyclotron waves are calculated. The vertical penetration of the plasma wave amplitudes is iestimated using a WKB analysis of the wave equation.

  11. Cyclotron laboratory of the Institute for Nuclear Research and Nuclear Energy

    Science.gov (United States)

    Tonev, D.; Goutev, N.; Georgiev, L. S.

    2016-06-01

    An accelerator laboratory is presently under construction in Sofia at the Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences. The laboratory will use a TR24 type of cyclotron, which provides a possibility to accelerate a proton beam with an energy of 15 to 24 MeV and current of up to 0.4 mA. An accelerator with such parameters allows to produce a large variety of radioisotopes for development of radiopharmaceuticals. The most common radioisotopes that could be produced with such a cyclotron are PET isotopes like: 11C, 13N, 15O, 18F, 124I, 64Cu, 68Ge/68Ga, and SPECT isotopes like: 123I, 111In, 67Ga, 57Co, 99m Tc. Our aim is to use the cyclotron facility for research in the fields of radiopharmacy, radiochemistry, radiobiology, nuclear physics, solid state physics, applied research, new materials and for education in all these fields including nuclear energy. The building of the laboratory will be constructed nearby the Institute for Nuclear Research and Nuclear Energy and the cyclotron together with all the equipment needed will be installed there.

  12. Alfvenic behavior of alpha particle driven ion cyclotron emission in TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Cauffman, S.; Majeski, R. [Princeton Plasma Physics Lab., NJ (United States); McClements, K.G. [UKAEA Government Division, Oxfordshire (United Kingdom). Euratom/UKAEA Fusion Association] [and others

    1995-07-01

    Ion cyclotron emission (ICE) has been observed during D-T discharges in the Tokamak Fusion Test Reactor (TFTR), using rf probes located near the top and bottom of the vacuum vessel. Harmonics of the alpha cyclotron frequency ({Omega}{sub {alpha}}) evaluated at the outer midplane plasma edge are observed at the onset of the beam injection phase of TFTR supershots, and persist for approximately 100-250 ms. These results are in contrast with observations of ICE in JET, in which harmonics of {Omega}{sub {alpha}} evolve with the alpha population in the plasma edge. Such differences are believed to be due to the fact that newly-born fusion alpha particles are super-Alfvenic near the edge of JET plasmas, while they are sub-Alfvenic near the edge of TFTR supershot plasmas. In TFTR discharges with edge densities such that newly-born alpha particles are super-Alfvenic, alpha cyclotron harmonics are observed to persist. These results are in qualitative agreement with numerical calculations of growth rates due to the magnetoacoustic cyclotron instability.

  13. Instability of Annular Beam with Finite Thickness in Dielectric-Loaded Cylindrical Waveguide

    OpenAIRE

    Tamura, Shusuke; Yamakawa, Mitsuhisa; Takashima, Yusuke; Ogura, Kazuo

    2008-01-01

    The cherenkov and slow cyclotron instabilities driven by an axially injected electron beam in a cylindrical waveguide are studied using a new version of the self-consistent linear theory considering three-dimensional beam perturbations. There are three kinds of models for beam instability analysis, which are based on a cylindrical solid beam, an infinitesimally thin annular beam, and a finitely thick annular beam. Among these models, the beam shape properly representing the often used actual ...

  14. Radioactive ion beam development in Berkeley

    CERN Document Server

    Wutte, D C; Leitner, M A; Xie, Z Q

    1999-01-01

    Two radioactive ion beam projects are under development at the 88" Cyclotron, BEARS (Berkeley Experiment with accelerated radioactive species) and the 14O experiment. The projects are initially focused on the production of 11C and 14O, but it is planned to expand the program to 17F, 18F, 13N and 76Kr. For the BEARS project, the radioactivity is produced in form of either CO2 or N2O in a small medical 10 MeV proton cyclotron. The activity is then transported through a 300 m long He-jet line to the 88" cyclotron building, injected into the AECR-U ion source and accelerated through the 88" cyclotron to energies between 1 to 30 MeV/ nucleon. The 14O experiment is a new experiment at the 88" cyclotron to measure the energy-shape of the beta decay spectrum. For this purpose, a target transfer line and a radioactive ion beam test stand has been constructed. The radioactivity is produced in form of CO in a hot carbon target with a 20 MeV 3He from the 88" Cyclotron. The activity diffuses through an 8m long stainless s...

  15. Coupled operation of the Oak Ridge isochronous cyclotron and the 25 MV tandem

    Energy Technology Data Exchange (ETDEWEB)

    Lord, R.S.; Ball, J.B.; Beckers, R.M.; Cleary, T.P.; Hudson, E.D.; Ludemann, C.A.; Martin, J.A.; Milner, W.T.; Mosko, S.W.; Ziegler, N.F.

    1981-01-01

    Coupled operation of the 25 MV tandem and the Oak Ridge Isochronous Cyclotron (ORIC) was achieved on January 27, 1981. A beam of 38 MeV /sup 16/O/sup 2 +/ was injected into ORIC, stripped to 8/sup +/ and accelerated to 324 MeV. Shortly afterwards, the energy was increased to the maximum design value of 25 MeV/amu (400 MeV). A spectrum taken of the scattering of this beam from a thin /sup 208/Pb target in the broad range spectrograh exhibited a resolution of 115 keV (FWHM). Performance of the system was in close agreement with that predicted from calculations.

  16. Direct injection into the IsoDAR Cyclotron using a RFQ

    Science.gov (United States)

    Axani, Spencer; IsoDAR Collaboration

    2015-04-01

    Beginning in the 1970s, the use of Radio Frequency Quadrupoles (RFQs) has been pervasive in linear accelerators in order to accelerate, bunch, and separate ion species. Current research suggests this may be an ideal way to inject a low energy H2+ beam axially into a cyclotron. The IsoDAR (Isotope Decay At Rest) experiment aims to implement this injection system in order to achieve higher Low Energy Beam Transport (LEBT) efficiencies and ultimately construct a novel compact neutrino factory to test the hypothesis of sterile neutrinos. This talk will focus on the research and development needed to implement a RFQ into the IsoDAR experiment.

  17. Bio-Nano ECRIS: an electron cyclotron resonance ion source for new materials production.

    Science.gov (United States)

    Uchida, T; Minezaki, H; Tanaka, K; Muramatsu, M; Asaji, T; Kato, Y; Kitagawa, A; Biri, S; Yoshida, Y

    2010-02-01

    We developed an electron cyclotron resonance ion source (ECRIS) for new materials production on nanoscale. Our main target is the endohedral fullerenes, which have potential in medical care, biotechnology, and nanotechnology. In particular, iron-encapsulated fullerene can be applied as a contrast material for magnetic resonance imaging or microwave heat therapy. Thus, our new ECRIS is named the Bio-Nano ECRIS. In this article, the recent progress of the development of the Bio-Nano ECRIS is reported: (i) iron ion beam production using induction heating oven and (ii) optimization of singly charged C(60) ion beam production.

  18. Are on-line currencies virtual banknotes?

    OpenAIRE

    Stephen F. Quinn; William Roberds

    2003-01-01

    The history of money is marked by innovations that have expanded the role of "inside money"-money created by the private sector. For instance, the past few years have seen the development of several types of on-line payment arrangements, some of which have been dubbed "on-line currencies." ; This article examines the likely success or failure of on-line currencies by means of a historical analogy. The discussion compares the introduction of on-line currencies to the debut of the bearer bankno...

  19. A proposal for a novel H ion source based on electron cyclotron resonance heating and surface ionization

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie A [Los Alamos National Laboratory; Kurennoy, Sergey [Los Alamos National Laboratory

    2008-01-01

    A design for a novel H{sup -} ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE{sub 111} eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H{sup -} ion beam is further 'self-extracted' through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H{sup -} ion current, beam emittance and duty factor of the novel source are estimated.

  20. A Proposal for a Novel H- Ion Source Based on Electron Cyclotron Resonance Plasma Heating and Surface Ionization

    Science.gov (United States)

    Tarvainen, O.; Kurennoy, S.

    2009-03-01

    A design for a novel H- ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE111 eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H- ion beam is further "self-extracted" through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H- ion current, beam emittance and duty factor of the novel source are estimated.

  1. Acceleration of positrons by a relativistic electron beam in the presence of quantum effects

    Energy Technology Data Exchange (ETDEWEB)

    Niknam, A. R. [Laser and Plasma Research Institute, Shahid Beheshti University, G.C., Tehran (Iran, Islamic Republic of); Aki, H.; Khorashadizadeh, S. M. [Physics Department, Birjand University, Birjand (Iran, Islamic Republic of)

    2013-09-15

    Using the quantum magnetohydrodynamic model and obtaining the dispersion relation of the Cherenkov and cyclotron waves, the acceleration of positrons by a relativistic electron beam is investigated. The Cherenkov and cyclotron acceleration mechanisms of positrons are compared together. It is shown that growth rate and, therefore, the acceleration of positrons can be increased in the presence of quantum effects.

  2. A Rare-Ion Beam Facility at iThemba LABS

    Science.gov (United States)

    Bark, R. A.

    2015-11-01

    iThemba LABS, chiefly based around a k=200 Separated Sector Cyclotron (SSC), is a multidisciplinary facility engaged in basic nuclear physics research, materials research, radionuclide production and hadron therapy. A proposal to acquire a new cyclotron to produce rare-ion beams for nuclear and materials research is outlined.

  3. First online production of radioactive ion beams at VECC

    Energy Technology Data Exchange (ETDEWEB)

    Naik, Vaishali, E-mail: vaishali@vecc.gov.in [Variable Energy Cyclotron Centre (VECC), Sector-1 Block-AF, Bidhan Nagar, Kolkata 700064 (India); Chakrabarti, Alok; Bhattacharjee, Mahuwa; Karmakar, Prasanta [Variable Energy Cyclotron Centre (VECC), Sector-1 Block-AF, Bidhan Nagar, Kolkata 700064 (India); Bhattacharjee, Sampa [UGC-DAE CSR, Kolkata Centre, III/LB-8, Bidhan Nagar, Kolkata 700098 (India); Bandyopadhyay, Arup; Dechoudhury, Siddhartha; Kumar, Dodi Lavanya; Mondal, Manas; Pandey, H.K.; Mandi, T.K.; Dutta, D.P.; Roy, Tapatee Kundu; Bhowmik, Debasis; Sanyal, Dirtha; Ray, Ayan; Sabir Ali, Md.; Srivastava, S.C.L.; Nabhiraj, P.Y. [Variable Energy Cyclotron Centre (VECC), Sector-1 Block-AF, Bidhan Nagar, Kolkata 700064 (India)

    2013-12-15

    Highlights: • We have presented details of a gas-jet transport and catcher technique for on-line production of radioactive ion beams (RIB). • Radioactive ion beams of {sup 14}O (71 s), {sup 42}K(12.4 h), {sup 43}K (22.2 h) and {sup 41}Ar (1.8 h) have been produced using the technique. • A combined efficiency of 15–21% has been measured for diffusion through the catcher, ionization and extraction of RIB through the ECR ion-source. • Preliminary data from alpha-particle induced fission of {sup 232}Th indicates the possibility of many fission products getting transported through the gas-jet coupled ECR ion-source. -- Abstract: Radioactive ion beams (RIB) have been recently accelerated for the first time at the VECC-RIB facility. Beams of {sup 14}O (71 s), {sup 42}K (12.4 h), {sup 43}K (22 h) and {sup 41}Ar (1.8 h) have been produced by bombarding 1 atm nitrogen and argon gas targets with 1 micro-ampere proton and alpha particle beams from the K130 cyclotron. Radioactive atoms were transported 15 m away to the ECR ion-source using a gas-jet transport system. Typical measured intensity of RIB at the separator focal plane is few times 10{sup 3} pps. About 3300 pps of 1.4 MeV {sup 14}O was measured after acceleration through a 3.4 m long RFQ linac. The details of the gas-jet coupled ECR and RIB production experiments are presented.

  4. Imaging Cyclotron Orbits of Electrons in Graphene.

    Science.gov (United States)

    Bhandari, Sagar; Lee, Gil-Ho; Klales, Anna; Watanabe, Kenji; Taniguchi, Takashi; Heller, Eric; Kim, Philip; Westervelt, Robert M

    2016-03-09

    Electrons in graphene can travel for several microns without scattering at low temperatures, and their motion becomes ballistic, following classical trajectories. When a magnetic field B is applied perpendicular to the plane, electrons follow cyclotron orbits. Magnetic focusing occurs when electrons injected from one narrow contact focus onto a second contact located an integer number of cyclotron diameters away. By tuning the magnetic field B and electron density n in the graphene layer, we observe magnetic focusing peaks. We use a cooled scanning gate microscope to image cyclotron trajectories in graphene at 4.2 K. The tip creates a local change in density that casts a shadow by deflecting electrons flowing nearby; an image of flow can be obtained by measuring the transmission between contacts as the tip is raster scanned across the sample. On the first magnetic focusing peak, we image a cyclotron orbit that extends from one contact to the other. In addition, we study the geometry of orbits deflected into the second point contact by the tip.

  5. Tokamak startup with electron cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Holly, D J; Prager, S C; Shepard, D A; Sprott, J C

    1980-04-01

    Experiments are described in which the startup voltage in a tokamak is reduced by approx. 60% by the use of a modest amount of electron cyclotron resonance heating power for preionization. A 50% reduction in volt-second requirement and impurity reflux are also observed.

  6. <600> MeV synchro-cyclotron

    CERN Multimedia

    1971-01-01

    One of the 14 pancakes of the new magnet coils for the 600 MeV synchro-cyclotron which were wound and coated with epoxy resin on the CERN site. These new coils will replace the present ones which have been in use for more than 14 years but are now showing signs of deteriorations.

  7. Stability of the Electron Cyclotron Resonance

    Science.gov (United States)

    Asch, Joachim; Bourget, Olivier; Meresse, Cédric

    2015-12-01

    We consider the magnetic AC Stark effect for the quantum dynamics of a single particle in the plane under the influence of an oscillating homogeneous electric and a constant perpendicular magnetic field. We prove that the electron cyclotron resonance is insensitive to impurity potentials.

  8. The irradiation facility at the AGOR cyclotron

    NARCIS (Netherlands)

    Brandenburg, Sytze; Ostendorf, Reint; Hofstee, Mariet; Kiewiet, Harry; Beijers, Hans

    2007-01-01

    The KVI is conducting radiobiology research using protons up to 190 MeV from the superconducting AGOR cyclotron in collaboration with the University Medical Center Groningen (UMCG) since 1998. Using the same set-up, we have started irradiations for radiation hardness studies of detectors and compone

  9. Electron cyclotron resonance heating on TEXTOR

    NARCIS (Netherlands)

    Westerhof, E.; Hoekzema, J. A.; Hogeweij, G. M. D.; Jaspers, R. J. E.; Schüller, F. C.; Barth, C. J.; Bongers, W. A.; Donne, A. J. H.; Dumortier, P.; van der Grift, A. F.; van Gorkom, J. C.; Kalupin, D.; Koslowski, H. R.; Kramer-Flecken, A.; Kruijt, O. G.; Cardozo, N. J. L.; Mantica, P.; van der Meiden, H. J.; Merkulov, A.; Messiaen, A.; Oosterbeek, J. W.; Oyevaar, T.; Poelman, A. J.; Polman, R. W.; Prins, P. R.; Scholten, J.; Sterk, A. B.; Tito, C. J.; Udintsev, V.S.; Unterberg, B.; Vervier, M.; van Wassenhove, G.

    2003-01-01

    The 110 GHz and the new 140 GHz gyrotron systems for electron cyclotron resonance heating (ECRH) and ECCD on TEXTOR are described and results of ECRH experiments with the 110 GHz system are reported. Central ECRH on Ohmic plasmas shows the presence of an internal electron transport barrier near q =

  10. On line routing per mobile phone

    DEFF Research Database (Denmark)

    Bieding, Thomas; Görtz, Simon; Klose, Andreas

    2009-01-01

    On-line routing is concerned with building vehicle routes in an ongoing fashion in such a way that customer requests arriving dynamically in time are efficiently and effectively served. An indispensable prerequisite for applying on-line routing methods is mobile communication technology. Addition...

  11. Simulation of Electron Behavior in PIG Ion Source for 9MeV Cyclotron

    CERN Document Server

    Ghergherehchi, Mitra; Yeon, Yeong- Heum; Chai, Jong- Seo

    2013-01-01

    In this paper, we focus on a PIG source for producing intense H-ions inside a 9MeV cyclotron. The properties of the PIG ion source were simulated for a variety of electric field distributions and magnetic field strengths using CST Particle Studio. After analyzing secondary electron emission (SEE) as a function of both magnetic and electric field strengths, we found that for the modeled PIG geometry a magnetic field strength of 0.2 T provided the best results in term of number of secondary electrons. Furthermore, at 0.2 T the number of secondary electrons proved to be greatest regardless of the cathode potential. Also the modified PIG ion source with quartz insulation tubes was tested in KIRAMS-13 cyclotron by varying gas flow rate and arc current, respectively. The capacity of the designed ion source was also demonstrated by producing plasma inside the constructed 9MeV cyclotron. As a result, the ion source is verified to be capable to produce intense H- beam and high ion beam current for the desired 9 MeV cy...

  12. EVIDENCE OF LANDAU AND CYCLOTRON RESONANCE BETWEEN PROTONS AND KINETIC WAVES IN SOLAR WIND TURBULENCE

    Energy Technology Data Exchange (ETDEWEB)

    He, Jiansen; Wang, Linghua; Tu, Chuanyi; Zong, Qiugang [School of Earth and Space Sciences, Peking University, Beijing 100871 (China); Marsch, Eckart, E-mail: jshept@gmail.com [Institute for Experimental and Applied Physics, Christian-Albrechts-Universität zu Kiel, D-24118 Kiel (Germany)

    2015-02-20

    The wave–particle interaction processes occurring in the solar wind provide crucial information to understand the wave dissipation and simultaneous particle heating in plasma turbulence. One requires observations of both wave fluctuations and particle kinetics near the dissipation range, which have, however, not yet been analyzed simultaneously. Here we show new evidence of wave–particle interactions by combining the diagnosis of wave modes with the analysis of particle kinetics on the basis of measurements from the WIND spacecraft with a high cadence of about 3 s. Solar wind protons appear to be highly dynamic in their velocity distribution consisting of varying anisotropic core and beam components. The basic scenario of solar wind proton heating through wave–particle interaction is suggested to be the following. Left-handed cyclotron resonance occurs continuously, and is evident from the observed proton core velocity distribution and the concurrent quasi-parallel left-handed Alfvén cyclotron waves. Landau and right-handed cyclotron resonances are persistent and indicated by the observed drifting anisotropic beam and the simultaneous quasi-perpendicular right-handed kinetic Alfvén waves in a general sense. The persistence of non-gyrotropic proton distributions may cast new light on the nature of the interaction between particles and waves near and beyond the proton gyro-frequency.

  13. AC Power Supply for Wobbler Magnet of the MC-50 Cyclotron

    CERN Document Server

    Kim, Yu-Seok; Kang, Bong-Koo; Lee, Hong-Gi; Park, Ki-Hyeon; Wha Chung, Chin; Woo Lee, Wol

    2005-01-01

    The MC-50 cyclotron (k=50) produces the ion beam for nuclear physics, chemistry, and applied researches in Korea. It has a small beam diameter with Gaussian beam shape, whereas many users want a beam irradiation on a large target. A wobbler magnet and an AC power supply were designed and constructed to meet the users' requirement. The power supply has two independently operating channels for the vertical and horizontal coils of the wobbler magnet. The frequency of the AC power supply for both coils is programmable from 1 to 20 Hz in a step of 1 Hz, and the maximum rms output current is 12 A. Various properties of the power supply and experimental results are given in the paper.

  14. Review of highly charged heavy ion production with electron cyclotron resonance ion source (invited)

    Science.gov (United States)

    Nakagawa, T.

    2014-02-01

    The electron cyclotron resonance ion source (ECRIS) plays an important role in the advancement of heavy ion accelerators and other ion beam applications worldwide, thanks to its remarkable ability to produce a great variety of intense highly charged heavy ion beams. Great efforts over the past decade have led to significant ECRIS performance improvements in both the beam intensity and quality. A number of high-performance ECRISs have been built and are in daily operation or are under construction to meet the continuously increasing demand. In addition, comprehension of the detailed and complex physical processes in high-charge-state ECR plasmas has been enhanced experimentally and theoretically. This review covers and discusses the key components, leading-edge developments, and enhanced ECRIS performance in the production of highly charged heavy ion beams.

  15. Development of a surface ionization source for the production of radioactive alkali ion beams in SPIRAL

    Energy Technology Data Exchange (ETDEWEB)

    Eleon, C. [GANIL, CEA/DSM CNRS/IN2P3, Bd H. Becquerel, BP 55027, 14076 CAEN cedex 5 (France)], E-mail: sceleon@triumf.ca; Jardin, P.; Gaubert, G.; Saint-Laurent, M.-G.; Alcantara-Nunez, J.; Alves Conde, R.; Barue, C.; Boilley, D.; Cornell, J. [GANIL, CEA/DSM CNRS/IN2P3, Bd H. Becquerel, BP 55027, 14076 CAEN cedex 5 (France); Delahaye, P. [3 CERN ISOLDE, 1211 Geneva 23 (Switzerland); Dubois, M.; Jacquot, B.; Leherissier, P.; Leroy, R.; Lhersonneau, G. [GANIL, CEA/DSM CNRS/IN2P3, Bd H. Becquerel, BP 55027, 14076 CAEN cedex 5 (France); Marie-Jeanne, M. [3 CERN ISOLDE, 1211 Geneva 23 (Switzerland); Maunoury, L. [CIRIL, Bd H. Becquerel, BP 55027, 14076 CAEN cedex 5 (France); Pacquet, J.Y.; Pellemoine, F. [GANIL, CEA/DSM CNRS/IN2P3, Bd H. Becquerel, BP 55027, 14076 CAEN cedex 5 (France); Pierret, C. [CIRIL, Bd H. Becquerel, BP 55027, 14076 CAEN cedex 5 (France)] (and others)

    2008-10-15

    In the framework of the production of radioactive alkali ion beams by the isotope separation on-line (ISOL) method in SPIRAL I, a surface ionization source has been developed at GANIL to produce singly-charged ions of Li, Na and K. This new source has been designed to work in the hostile environment whilst having a long lifetime. This new system of production has two ohmic heating components: the first for the target oven and the second for the ionizer. The latter, being in carbon, offers high reliability and competitive ionization efficiency. This surface ionization source has been tested on-line using a {sup 48}Ca primary beam at 60.3 A MeV with an intensity of 0.14 pA. The ionization efficiencies obtained for Li, Na and K are significantly better than the theoretical values of the ionization probability per contact. The enhanced efficiency, due to the polarization of the ionizer, is shown to be very important also for short-lived isotopes. In the future, this source will be associated with the multicharged electron-cyclotron-resonance (ECR) ion source NANOGAN III for production of multicharged alkali ions in SPIRAL. The preliminary tests of the set up are also presented in this contribution.

  16. A preliminary study of a negative hydrogen PIG-type ion source for the compact cyclotron

    Institute of Scientific and Technical Information of China (English)

    YANG Zhen; LONG Ji-Dong; DONG Pan; WANG Tao; WEI Tao; HE Xiao-Zhong; ZHANG Kai-Zhi; SHI Jin-Shui

    2012-01-01

    A Penning ion gauge (PIG)-type ion source has been used for the generation of negative hydrogen ions (H-) as the internal ion source of the compact cyclotron.The discharge characteristics of the ion source are systematically studied for hydrogen operation at different discharge currents and gas flow rates on the prototype cyclotron.The preliminary study results for the low DC voltage H- extraction measurements are presented in this paper.The H- beam current is measured by the order of magnitude from several tens to hundreds of microamperes at different parameter conditions.The discussion and analysis for the experimental results are good for improving the design and working stability of the ion source.

  17. Study of the neutron field in the vicinity of an unshielded PET cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, R [Dpto. Fisica Teorica, Atomica y Optica, Universidad de Valladolid (Spain); Iniguez, M P [Dpto. Fisica Teorica, Atomica y Optica, Universidad de Valladolid (Spain); MartI-Climent, J M [Servicio de Medicina Nuclear, ClInica Universitaria de Navarra (Spain); Penuelas, I [Servicio de Medicina Nuclear, ClInica Universitaria de Navarra (Spain); Vega-Carrillo, H R [Dpto. Estudios Nucleares, IngenierIa Electrica, Matematicas, Universidad Autonoma de Zacatecas (Mexico); Barquero, R [Hospital Universitario RIo Hortega, Valladolid (Spain)

    2005-11-07

    The neutron field in the proximity of an unshielded PET cyclotron was investigated during {sup 18}F radioisotope production with an 18 MeV proton beam. Thermoluminescent detector (TLD) models TLD600 and TLD700 as well as Bonner moderating spheres were irradiated at different positions inside the vault room where the cyclotron is located to determine the thermal neutron flux, neutron spectrum and dose equivalent. Furthermore, from a combination of measurements and Monte Carlo simulations the neutron source intensity at the target was estimated. The resulting intensity is in good agreement with the IAEA recommendations. Neutron doses derived from the measured spectra were found to vary between 7 and 320 mSv per 1 {mu}A h of proton-integrated current. Finally, gamma doses were determined from TLD700 readings and amounted to around 10% of the neutron doses.

  18. Study of the neutron field in the vicinity of an unshielded PET cyclotron.

    Science.gov (United States)

    Méndez, R; Iñiguez, M P; Martí-Climent, J M; Peñuelas, I; Vega-Carrillo, H R; Barquero, R

    2005-11-01

    The neutron field in the proximity of an unshielded PET cyclotron was investigated during 18F radioisotope production with an 18 MeV proton beam. Thermoluminescent detector (TLD) models TLD600 and TLD700 as well as Bonner moderating spheres were irradiated at different positions inside the vault room where the cyclotron is located to determine the thermal neutron flux, neutron spectrum and dose equivalent. Furthermore, from a combination of measurements and Monte Carlo simulations the neutron source intensity at the target was estimated. The resulting intensity is in good agreement with the IAEA recommendations. Neutron doses derived from the measured spectra were found to vary between 7 and 320 mSv per 1 microA h of proton-integrated current. Finally, gamma doses were determined from TLD700 readings and amounted to around 10% of the neutron doses.

  19. Potential of ion cyclotron resonance frequency current drive via fast waves in DEMO

    Science.gov (United States)

    Kazakov, Ye O.; Van Eester, D.; Wauters, T.; Lerche, E.; Ongena, J.

    2015-02-01

    For the continuous operation of future tokamak-reactors like DEMO, non-inductively driven toroidal plasma current is needed. Bootstrap current, due to the pressure gradient, and current driven by auxiliary heating systems are currently considered as the two main options. This paper addresses the current drive (CD) potential of the ion cyclotron resonance frequency (ICRF) heating system in DEMO-like plasmas. Fast wave CD scenarios are evaluated for both the standard midplane launch and an alternative case of exciting the waves from the top of the machine. Optimal ICRF frequencies and parallel wave numbers are identified to maximize the CD efficiency. Limitations of the high frequency ICRF CD operation are discussed. A simplified analytical method to estimate the fast wave CD efficiency is presented, complemented with the discussion of its dependencies on plasma parameters. The calculated CD efficiency for the ICRF system is shown to be similar to those for the negative neutral beam injection and electron cyclotron resonance heating.

  20. Cyclotron production of (44)Sc: From bench to bedside.

    Science.gov (United States)

    van der Meulen, Nicholas P; Bunka, Maruta; Domnanich, Katharina A; Müller, Cristina; Haller, Stephanie; Vermeulen, Christiaan; Türler, Andreas; Schibli, Roger

    2015-09-01

    (44)Sc, a PET radionuclide, has promising decay characteristics (T1/2 = 3.97 h, Eβ(+)av = 632 keV) for nuclear imaging and is an attractive alternative to the short-lived (68)Ga (T1/2 = 68 min, Eβ(+)av = 830 keV). The aim of this study was the optimization of the (44)Sc production process at an accelerator, allowing its use for preclinical and clinical PET imaging. (44)CaCO3 targets were prepared and irradiated with protons (~11 MeV) at a beam current of 50 μA for 90 min. (44)Sc was separated from its target material using DGA extraction resin and concentrated using SCX cation exchange resin. Radiolabeling experiments at activities up to 500 MBq and stability tests were performed with DOTANOC by investigating different scavengers, including gentisic acid. Dynamic PET of an AR42J tumor-bearing mouse was performed after injection of (44)Sc-DOTANOC. The optimized chemical separation method yielded up to 2 GBq (44)Sc of high radionuclidic purity. In the presence of gentisic acid, radiolabeling of (44)Sc with DOTANOC was achieved with a radiochemical yield of ~99% at high specific activity (10 MBq/nmol) and quantities which would allow clinical application. The dynamic PET images visualized increasing uptake of (44)Sc-DOTANOC into AR42J tumors and excretion of radioactivity through the kidneys of the investigated mouse. The concept "from-bench-to-bedside" was clearly demonstrated in this extended study using cyclotron-produced (44)Sc. Sufficiently high activities of (44)Sc of excellent radionuclidic purity are obtainable for clinical application, by irradiation of enriched calcium at a cyclotron. This work demonstrates a promising basis for introducing (44)Sc to clinical routine of nuclear imaging using PET. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Analysis of relay based valley coil system of K-130 Cyclotron and an approach to computer controlled system

    Energy Technology Data Exchange (ETDEWEB)

    Shoor, B.

    2016-09-11

    To overcome the first harmonic field imperfection in sector focused cyclotron, a set of coils placed in valleys are used to produce an opposite first harmonic effect. Usually, at the time of beam tuning the phase of the first harmonic is varied using a relay system. It can be shown analytically that magnitude of it changes simultaneously, when phase is changed. This is not desirable at the time of beam tuning. Moreover phase changes in long steps, which hampers accuracy of beam tuning. To overcome this, a computer controlled system is suggested where amplitude remains constant at the time of phase change. Moreover, phase can be changed continuously which gives better tuning accuracy.

  2. Identification and Angular Distribution of Residual Radionuclides Detected on the Wall of BATAN’s Cyclotron Cave

    Directory of Open Access Journals (Sweden)

    I. Kambali

    2016-04-01

    Full Text Available Detection and measurement of radiation sources around BATAN’s cyclotron facilities in Serpong are required as an early step to avoid radiation impacts on the radiation employees who work with the cyclotron. In this paper, radiation emitted from the wall of the CS-30 cyclotron cave are detected and measured using an NaI(Tl detector coupled with a pocket multichannel analyzer (MCA at a counting time of 30 minutes for each sampling point on the wall. The sampling points were in the directions of within ±150o with respect to the incoming proton beams, and the measurements were conducted at heights between 1.2 m and 1.8 m off the floor for every sampling point. The experimental results indicate that Co-60 and Cs-134 detected on the cyclotron cave wall are major radionuclides that contribute to the emitted gamma radiation. The distribution of the gamma ray intensities given off by Co-60 and Cs-134 depend on the angle and position of the sampling points. In general the highest gamma ray rates can be found in the area around 0o relative to the incoming proton beams. In addition, no other radioactive sources are significantly detected on the wall. The maximum exposure measured on the wall surface was much less than the permissible occupational exposure for radiation workers and general public.

  3. On-line generalized Steiner problem

    Energy Technology Data Exchange (ETDEWEB)

    Awerbuch, B.; Azar, Y.; Bartal, Y. [Tel Aviv Univ. (Israel)

    1996-12-31

    The Generalized Steiner Problem (GSP) is defined as follows. We are given a graph with non-negative weights and a set of pairs of vertices. The algorithm has to construct minimum weight subgraph such that the two nodes of each pair are connected by a path. We consider the on-line generalized Steiner problem, in which pairs of vertices arrive on-line and are needed to be connected immediately. We give a simple O(log{sup 2} n) competitive deterministic on-line algorithm. The previous best online algorithm (by Westbrook and Yan) was O({radical}n log n) competitive. We also consider the network connectivity leasing problem which is a generalization of the GSP. Here edges of the graph can be either bought or leased for different costs. We provide simple randomized O(log{sup 2} n) competitive algorithm based on the on-line generalized Steiner problem result.

  4. The war against on-line piracy

    OpenAIRE

    Harris, Julian

    2011-01-01

    A summary by Julian Harris, Deputy General Editor Amicus Curiae, of US attempts to control what it identifies as rogue Internet sites engaged in on-line piracy and opposition to such legislative moves.

  5. On-Line Acquisitions by LOLITA

    Directory of Open Access Journals (Sweden)

    Frances G. Spigai

    1970-12-01

    Full Text Available The on-line acquisition program (LOLITA in use at the Oregon State University Library is described in terms of development costs, equipment requirements, and overall design philosophy. In particular, the record format and content of records in the on-order file, and the on-line processing of these records (input, search, correction, output using a cathode ray tube display terminal are detailed.

  6. ACSEPP On-Line Electronic Payment Protocol

    Institute of Scientific and Technical Information of China (English)

    WANG Shao-bin; ZHU Xian; HONG Fan

    2004-01-01

    With analyzing the existing on-line electronic payment protocols, this paper presents a new on-line electronic payment protocol named ACSEPP: Anonymous, Convenient and Secure Electronic Payment Protocol.Its aim is to design a practical electronic payment protocol which is both secure and convenient.Without using PKI_CA frame, it realized the anonymity of consumer and merchant, the convenient of handling, the low cost of maintenance and the security.

  7. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency

    Science.gov (United States)

    Nagornov, Konstantin O.; Kozhinov, Anton N.; Tsybin, Yury O.

    2017-02-01

    The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω c . In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω c quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω+), whereas the ω c and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω+ quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω c frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω+ frequencies can be reduced to negligible levels relative to peaks close to ω c frequencies. Due to reduced errors with which the ω c quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω+ frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences.

  8. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.

    Science.gov (United States)

    Nagornov, Konstantin O; Kozhinov, Anton N; Tsybin, Yury O

    2017-04-01

    The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω c . In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω c quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω+), whereas the ω c and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω+ quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω c frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω+ frequencies can be reduced to negligible levels relative to peaks close to ω c frequencies. Due to reduced errors with which the ω c quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω+ frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. Graphical Abstract ᅟ.

  9. New developments of {sup 11}C post-accelerated beams for hadron therapy and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Augusto, R.S., E-mail: r.s.augusto@cern.ch [European Organization for Nuclear Research – CERN, 1211 Geneva 23 (Switzerland); Ludwig Maximilians – University of Munich, Munich (Germany); Mendonca, T.M.; Wenander, F. [European Organization for Nuclear Research – CERN, 1211 Geneva 23 (Switzerland); Penescu, L. [MedAustron GmbH, Wiener Neustadt (Austria); Orecchia, R. [CNAO – Centro Nazionale di Adroterapia Oncologica per il trattamento dei tumori, Pavia (Italy); Parodi, K. [Ludwig Maximilians – University of Munich, Munich (Germany); Ferrari, A.; Stora, T. [European Organization for Nuclear Research – CERN, 1211 Geneva 23 (Switzerland)

    2016-06-01

    Hadron therapy was first proposed in 1946 and is by now widespread throughout the world, as witnessed with the design and construction of the CNAO, HIT, PROSCAN and MedAustron treatment centres, among others. The clinical interest in hadron therapy lies in the fact that it delivers precision treatment of tumours, exploiting the characteristic shape (the Bragg peak) of the energy deposition in the tissues for charged hadrons. In particular, carbon ion therapy is found to be biologically more effective, with respect to protons, on certain types of tumours. Following an approach tested at NIRS in Japan [1], carbon ion therapy treatments based on {sup 12}C could be combined or fully replaced with {sup 11}C PET radioactive ions post-accelerated to the same energy. This approach allows providing a beam for treatment and, at the same time, to collect information on the 3D distributions of the implanted ions by PET imaging. The production of {sup 11}C ion beams can be performed using two methods. A first one is based on the production using compact PET cyclotrons with 10–20 MeV protons via {sup 14}N(p,α){sup 11}C reactions following an approach developed at the Lawrence Berkeley National Laboratory [2]. A second route exploits spallation reactions {sup 19}F(p,X){sup 11}C and {sup 23}Na(p,X){sup 11}C on a molten fluoride salt target using the ISOL (isotope separation on-line) technique [3]. This approach can be seriously envisaged at CERN-ISOLDE following recent progresses made on {sup 11}C{sup +} production [4] and proven post-acceleration of pure {sup 10}C{sup 3/6+} beams in the REX-ISOLDE linac [5]. Part of the required components is operational in radioactive ion beam facilities or commercial medical PET cyclotrons. The driver could be a 70 MeV, 1.2 mA proton commercial cyclotron, which would lead to 8.1 × 10{sup 711}C{sup 6+} per spill. This intensity is appropriate using {sup 11}C ions alone for both imaging and treatment. Here we report on the ongoing feasibility

  10. New developments of 11C post-accelerated beams for hadron therapy and imaging

    Science.gov (United States)

    Augusto, R. S.; Mendonca, T. M.; Wenander, F.; Penescu, L.; Orecchia, R.; Parodi, K.; Ferrari, A.; Stora, T.

    2016-06-01

    Hadron therapy was first proposed in 1946 and is by now widespread throughout the world, as witnessed with the design and construction of the CNAO, HIT, PROSCAN and MedAustron treatment centres, among others. The clinical interest in hadron therapy lies in the fact that it delivers precision treatment of tumours, exploiting the characteristic shape (the Bragg peak) of the energy deposition in the tissues for charged hadrons. In particular, carbon ion therapy is found to be biologically more effective, with respect to protons, on certain types of tumours. Following an approach tested at NIRS in Japan [1], carbon ion therapy treatments based on 12C could be combined or fully replaced with 11C PET radioactive ions post-accelerated to the same energy. This approach allows providing a beam for treatment and, at the same time, to collect information on the 3D distributions of the implanted ions by PET imaging. The production of 11C ion beams can be performed using two methods. A first one is based on the production using compact PET cyclotrons with 10-20 MeV protons via 14N(p,α)11C reactions following an approach developed at the Lawrence Berkeley National Laboratory [2]. A second route exploits spallation reactions 19F(p,X)11C and 23Na(p,X)11C on a molten fluoride salt target using the ISOL (isotope separation on-line) technique [3]. This approach can be seriously envisaged at CERN-ISOLDE following recent progresses made on 11C+ production [4] and proven post-acceleration of pure 10C3/6+ beams in the REX-ISOLDE linac [5]. Part of the required components is operational in radioactive ion beam facilities or commercial medical PET cyclotrons. The driver could be a 70 MeV, 1.2 mA proton commercial cyclotron, which would lead to 8.1 × 10711C6+ per spill. This intensity is appropriate using 11C ions alone for both imaging and treatment. Here we report on the ongoing feasibility studies of such approach, using the Monte Carlo particle transport code FLUKA [6,7] to simulate

  11. TFTR Michelson interferometer electron cyclotron emission diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Stauffer, F.J.; Boyd, D.A.; Cutler, R.C.; McCarthy, M.P.

    1985-05-01

    In July 1984, a Fourier transform spectrometer employing a fast-scanning Michelson interferometer began operating on TFTR. This diagnostic system can measure the electron cyclotron emission spectrum 72 times per s with a time resolution of 11 ms and a spectral resolution of 3.6 GHz. The initial operating spectral range is 75--540 GHz, which is adequate for measuring the first three cyclotron harmonics at present TFTR magnetic field levels. The range can be extended easily to 75--1080 GHz in order to accommodate increases in toroidal magnetic field or to study superthermal ECE. The measured spectra are absolutely calibrated using a liquid nitrogen cooled blackbody reference source. The second harmonic feature of each spectrum is used to calculate the absolute electron temperature profile.

  12. Hybrid simulation of electron cyclotron resonance heating

    CERN Document Server

    Ropponen, T; Suominen, P; Koponen, T K; Kalvas, T; Koivisto, H

    2008-01-01

    Electron Cyclotron Resonance (ECR) heating is a fundamentally important aspect in understanding the physics of Electron Cyclotron Resonance Ion Sources (ECRIS). Absorption of the radio frequency (RF) microwave power by electron heating in the resonance zone depends on many parameters including frequency and electric field strength of the microwave, magnetic field structure and electron and ion density profiles. ECR absorption has been studied in the past by e.g. modelling electric field behaviour in the resonance zone and its near proximity. This paper introduces a new ECR heating code that implements damping of the microwave power in the vicinity of the resonance zone, utilizes electron density profiles and uses right hand circularly polarized (RHCP) electromagnetic waves to simulate electron heating in ECRIS plasma.

  13. Hybrid simulation of electron cyclotron resonance heating

    Energy Technology Data Exchange (ETDEWEB)

    Ropponen, T. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FI-40014 (Finland)], E-mail: tommi.ropponen@phys.jyu.fi; Tarvainen, O. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Suominen, P. [CERN Geneve 23, CH-1211 (Switzerland); Koponen, T.K. [Department of Physics, University of Jyvaeskylae, Nanoscience Center, P.O. Box 35, FI-40014 (Finland); Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FI-40014 (Finland)

    2008-03-11

    Electron Cyclotron Resonance (ECR) heating is a fundamentally important aspect in understanding the physics of Electron Cyclotron Resonance Ion Sources (ECRIS). Absorption of the radio frequency (RF) microwave power by electron heating in the resonance zone depends on many parameters including frequency and electric field strength of the microwave, magnetic field structure and electron and ion density profiles. ECR absorption has been studied in the past by e.g. modelling electric field behaviour in the resonance zone and its near proximity. This paper introduces a new ECR heating code that implements damping of the microwave power in the vicinity of the resonance zone, utilizes electron density profiles and uses right hand circularly polarized (RHCP) electromagnetic waves to simulate electron heating in ECRIS plasma.

  14. Transmission efficiency improvement of the injector line of SFC by particle beam decorrelation

    Institute of Scientific and Technical Information of China (English)

    杨尧; 赵红卫; 原有进; 冯玉成; 孙良亭; 方兴; 卢旺; 张文慧; 曹云; 张雪珍

    2015-01-01

    The operation of the HIRFL accelerator has shown that the beam transmission efficiency of the sector focusing cyclotron (SFC) injector line is rather poor. Beam simulations have been performed to investigate the possible causes for this low transmission. It is predicted that the property of transversal coupling of the ion beam from electron cyclotron resonance (ECR) ion source can be an important factor to degrade the beam quality by increasing the beam emittance, resulting in a serious particle loss. An improved operation scheme for the SECRAL associated line has been proposed, and the corresponding experiment was carried out. This paper presents the test results.

  15. Ion Cyclotron Heating on Proto-MPEX

    Science.gov (United States)

    Goulding, R. H.; Caughman, J. B. O.; Rapp, J.; Biewer, T. M.; Campbell, I. H.; Caneses, J. F.; Kafle, N.; Ray, H. B.; Showers, M. A.; Piotrowicz, P. A.

    2016-10-01

    Ion cyclotron heating will be used on Proto-MPEX (Prototype Material Plasma Exposure eXperiment) to increase heat flux to the target, to produce varying ion energies without substrate biasing, and to vary the extent of the magnetic pre-sheath for the case of a tilted target. A 25 cm long, 9 cm diameter dual half-turn helical ion cyclotron antenna has been installed in the device located at the magnetic field maximum. It couples power to ions via single pass damping of the slow wave at the fundamental resonance, and operates with ω 0.8ωci at the antenna location. It is designed to operate at power levels up to 30 kW, with a later 200 kW upgrade planned. Near term experiments include measuring RF loading at low power as a function of frequency and antenna gap. The plasma is generated by a helicon plasma source that has achieved ne > 5 ×1019m-3 operating with deuterium, as measured downstream from the ion cyclotron antenna location. Measurements will be compared with 1-D and 2-D models of RF coupling. The latest results will be presented. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  16. Assessment of Electron-Cyclotron-Current-Drive-Assisted Operation in DEMO

    Directory of Open Access Journals (Sweden)

    Marushchenko N.B.

    2012-09-01

    Full Text Available The achievable efficiency for external current drive through electron-cyclotron (EC waves in a demonstration tokamak reactor is discussed. Two possible reactor designs, one for steady state and one for pulsed operation, are considered. It is found that for midplane injection the achievable current drive efficiency is limited by secondharmonic absorption at levels consistent with previous studies. Propagation through the second-harmonic region can be reduced by moving the launch position to the high-field side (this can be obtained by injecting the beam from an upper port in the vacuum vessel. In this case, beam tracing calculations deliver values for the EC current drive efficiency approaching those usually reported for neutral beam current drive.

  17. On the criteria guiding the design of the upper electron-cyclotron launcher for ITER

    Directory of Open Access Journals (Sweden)

    Poli E.

    2015-01-01

    Full Text Available Electron cyclotron waves injected from an antenna located in the upper part of the vessel will be employed in ITER to controlMHD instabilities, particularly neoclassical tearingmodes (NTMs. The derivation of the NTM stabilization criteria used up to now to guide the optimization of the launcher is reviewed in this paper and their range of validity elucidated. Possible effects leading to a deterioration of the predicted performance through a broadening of the EC deposition profile are discussed. The most detrimental effect will likely be the scattering of the EC beams from density fluctuations, resulting in a beam broadening in the 100% range. The combined impact of these effects with that of beam misalignment (with respect to the targeted surface is discussed for a time slice of the standard Q = 10 H-mode scenario.

  18. Formación on line

    Directory of Open Access Journals (Sweden)

    O. Grau-Perejoan

    Full Text Available La formación on line es una modalidad de enseñanza a distancia basada en las nuevas tecnologías. En este artículo se pretende hacer una introducción a base de describir a grandes rasgos sus características principales: asincronía, no presencialidad, comunicación escrita, función del profesor on line, así como los retos, los riesgos, las ventajas y los inconvenientes que plantea. Se exponen las diferencias entre la formación on line y la formación presencial, de manera que los docentes puedan adaptar de la mejor manera posible sus propuestas formativas a la modalidad on line. Se introduce el importantísimo papel de la planificación y de la fase de diseño y, finalmente, se repasan conceptos útiles para comprender mejor el mundo de la formación on line como son los conceptos entorno virtual de aprendizaje (EVA o Blended Learning (B-Learning.

  19. Matching from H(-) multicusp source to central region of a 100 MeV compact cyclotron for high current injection.

    Science.gov (United States)

    Yao, Hongjuan; Zhang, Tianjue; Lu, Yinlong; Jia, Xianlu; Guan, Fengping; Lin, Yuzheng

    2008-02-01

    The way of matching the beam from an external ion source to the central region of the cyclotron CYCIAE-100 is presented in this article. The transverse acceptances of the central region were calculated, which provided the matching ellipse parameter requirements to the injection transport optics design. The optics of the injection line was simulated using TRANSOPTR, which allowed space charge effect calculation, and neutralization was taken into account.

  20. Matching from H- multicusp source to central region of a 100MeV compact cyclotron for high current injectiona)

    Science.gov (United States)

    Yao, Hongjuan; Zhang, Tianjue; Lu, Yinlong; Jia, Xianlu; Guan, Fengping; Lin, Yuzheng

    2008-02-01

    The way of matching the beam from an external ion source to the central region of the cyclotron CYCIAE-100 is presented in this article. The transverse acceptances of the central region were calculated, which provided the matching ellipse parameter requirements to the injection transport optics design. The optics of the injection line was simulated using TRANSOPTR, which allowed space charge effect calculation, and neutralization was taken into account.

  1. The new solid target system at UNAM in a self-shielded 11 MeV cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Zarate-Morales, A.; Gaspar-Carcamo, R. E.; Lopez-Rodriguez, V.; Flores-Moreno, A.; Trejo-Ballado, F.; Avila-Rodriguez, Miguel A. [Unidad PET, Facultad de Medicina, Universidad Nacional Autonoma de Mexico, 04510 , D.F. Mexico (Mexico)

    2012-12-19

    A dual beam line (BL) self-shielded RDS 111 cyclotron for radionuclide production was installed at the School of Medicine of the National Autonomous University of Mexico in 2001. One of the BL's was upgraded to Eclipse HP (Siemens) in 2008 and the second BL was recently upgraded (June 2011) to the same version with the option for the irradiation of solid targets for the production of metallic radioisotopes.

  2. Structure modification and medical application of the natural products by proton beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. W.; Park, J. K.; Kang, J. E.; Shin, S. C.; Ahn, J. H.; Lee, E. S. [Dongguk University, Gyeongju (Korea, Republic of)

    2008-04-15

    This study was performed for the investigation of changes of constituent contents of Korean ginseng (Panax genseng C.A. Meyer) after proton beam irradiation (Beam energy from MC-50 cyclotron : 36.5MeV) with beam range of 500 - 10000Gy

  3. Progress in theory and simulation of ion cyclotron emission from magnetic confinement fusion plasmas

    Science.gov (United States)

    Dendy, Richard; Chapman, Ben; Chapman, Sandra; Cook, James; Reman, Bernard; McClements, Ken; Carbajal, Leopoldo

    2016-10-01

    Suprathermal ion cyclotron emission (ICE) is detected from all large tokamak and stellarator plasmas. Its frequency spectrum has narrow peaks at sequential cyclotron harmonics of the energetic ion population (fusion-born or neutral beam-injected) at the outer edge of the plasma. ICE was the first collective radiative instability driven by confined fusion-born ions observed in deuterium-tritium plasmas in JET and TFTR, and the magnetoacoustic cyclotron instability is the most likely emission mechanism. Contemporary ICE measurements are taken at very high sampling rates from the LHD stellarator and from the conventional aspect ratio KSTAR tokamak. A correspondingly advanced modelling capability for the ICE emission mechanism has been developed using 1D3V PIC and hybrid-PIC codes, supplemented by analytical theory. These kinetic codes simulate the self-consistent full orbit dynamics of energetic and thermal ions, together with the electric and magnetic fields and the electrons. We report recent progress in theory and simulation that addresses: the scaling of ICE intensity with energetic particle density; the transition between super-Alfvénic and sub-Alfvénic regimes for the collectively radiating particles; and the rapid time evolution that is seen for some ICE measurements. This work was supported in part by the RCUK Energy Programme [Grant Number EP/I501045] and by Euratom.

  4. Cyclotron Lines: From Magnetic Field Strength Estimators to Geometry Tracers in Neutron Stars

    Indian Academy of Sciences (India)

    Chandreyee Maitra

    2017-09-01

    With forty years since the discovery of the first cyclotron line in Her X-1, there have been remarkable advancements in the field related to the study of the physics of accreting neutron stars – cyclotron lines have been a major torchbearer in this regard, from being the only direct estimator of the magnetic field strength, a tracer of accretion geometry and an indicator of the emission beam in these systems. The main flurry of activities have centred around studying the harmonic separations, luminosity dependence, pulse phase dependence and more recently, the shapes of the line and the trend for long-term evolution in the line energy. This article visits the important results related to cyclotron lines since its discovery and reviews their significance. An emphasis is laid on pulse phase resolved spectroscopy and the important clues a joint timing and spectral study in this context can provide, to build a complete picture for the physics of accretion and hence X-ray emission in accreting neutron stars.

  5. Development of the RF cavity for the SKKUCY-9 compact cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seungwook; Lee, Jongchul [Department of Energy Science, Sungkyunkwan University, 2066, Seobu-Ro, Jangan-Gu, Suwon-si, Gyeonggi-do (Korea, Republic of); LEE, Byeong-No [Radiation Equipment Research Division, Korea Atomic Energy Research Institute, 111, Daedeok-daero 989 Beon-gil, Yuseong-gu, Daejeon (Korea, Republic of); Ha, Donghyup; Namgoong, Ho [College of Information & Communication Engineering, Sungkyunkwan University, 2066, Seobu-Ro, Jangan-Gu, Suwon-si, Gyeonggi-do (Korea, Republic of); Chai, Jongseo, E-mail: jschai@skku.edu [College of Information & Communication Engineering, Sungkyunkwan University, 2066, Seobu-Ro, Jangan-Gu, Suwon-si, Gyeonggi-do (Korea, Republic of)

    2015-09-21

    A 9 MeV compact cyclotron, named SKKUCY-9, for a radiopharmaceutical compound especially fludeoxyglucose (FDG) production for a positron emission tomography (PET) machine was developed at Sungkyunkwan University. H{sup −} ions which are produced from a Penning Ionization Gauge(PIG) ion source, travel through a normal conducting radio frequency (RF) cavity which operates at 83.2 MHz for an acceleration and electro-magnet for a beam focusing until the ions acquire energy of about 9 MeV. For installation at a small local hospital, our SKKUCY-9 cyclotron is developed to be compact and light-weight, comparable to conventional medical purpose cyclotrons. For compactness, we adapted a deep valley and large angle hill type for the electro-magnet design. Normally a RF cavity is installed inside of the empty space of the magnet valley region, which is extremely small in our case. We faced problems such as difficulties of installing the RF cavity, low Q-value. Despite of those difficulties, a compact RF cavity and its system including a RF power coupler to feed amplified RF power to the RF cavity and a fine tuner to compensate RF frequency variations was successfully developed and tested.

  6. Energy transfer between energetic ring current H(+) and O(+) by electromagnetic ion cyclotron waves

    Science.gov (United States)

    Thorne, Richard M.; Horne, Richard B.

    1994-01-01

    Electromagnetic ion cyclotron (EMIC) waves in the frequency range below the helium gyrofrequency can be excited in the equatorial region of the outer magnetosphere by cyclotron resonant instability with anisotropic ring current H(+) ions. As the unducted waves propagate to higher latitudes, the wave normal should become highly inclined to the ambient magnetic field. Under such conditions, wave energy can be absorbed by cyclotron resonant interactions with ambient O(+), leading to ion heating perpendicular to the ambient magnetic field. Resonant wave absorption peaks in the vicinity of the bi-ion frequency and the second harmonic of the O(+) gyrofrequrency. This absorption should mainly occur at latitudes between 10 deg and 30 deg along auroral field lines (L is greater than or equal to 7) in the postnoon sector. The concomitant ion heating perpendicular to the ambient magnetic field can contribute to the isotropization and geomagnetic trapping of collapsed O(+) ion conics (or beams) that originate from a low-altitude ionospheric source region. During geomagnetic storms when the O(+) content of the magnetosphere is significantly enhanced, the absorption of EMIC waves should become more efficient, and it may contribute to the observed acceleration of O(+) ions of ionospheric origin up to ring current energies.

  7. Ion cyclotron waves near comet C/2013 A1 (Siding Spring) and Mars

    Science.gov (United States)

    Crary, F. J.; Dols, V. J.; Connerney, J. E. P.; Espley, J. R.

    2014-12-01

    On October 19, 2014, comet C/2013 A1 (Siding Spring) passed approximately 135,000 km from Mars. Previously,we predicted the amplitude of ion cyclotron waves which might be observed during the Siding Spring encounter. Ioncyclotron waves have been observed both in the vicinity of comets and of Mars. These waves are generated by theionization of neutrals in the flowing solar wind, which produces an unstable ring-beam velocity distribution. We estimated that, for a production rate of 2x1028 s-1, ion cyclotron wave with amplitudes over 0.1 nT would be present within ‡5 hours (1.2 million km) of closest approach. We will compare the actual observations made by the MAVEN spacecraft with these predictions. The spacecraft was close to or downstream of the martian bow shock, which complicates the interpretation of the data. Taking thisinto account, we will describe the observations and their implications for wave activity and cometary neutral production. We also present updated hybrid simulations of ion cyclotron wave generation. The simulations use our best estimate of solar wind conditions at the time of the encounter and a variable injection of 18 AMU pickup ions, at a rates consistent a model of the cometary neutrals.

  8. Observation of increased ion cyclotron resonance signal duration through electric field perturbations.

    Science.gov (United States)

    Kaiser, Nathan K; Bruce, James E

    2005-09-15

    Ion motion in Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is complex and the subject of ongoing theoretical and experimental studies. Two predominant pathways for the loss of ICR signals are thought to include damping of cyclotron motion, in which ions lose kinetic energy and radially damp toward the center of the ICR cell, and dephasing of ion coherence, in which ions of like cyclotron frequency become distributed out of phase at similar cyclotron radii. Both mechanisms result in the loss of induced ion image current in FTICR-MS measurements and are normally inseparable during time-domain signal analysis. For conventional ICR measurements which take advantage of ion ensembles, maximization of the ion population size and density can produce the desired effect of increasing phase coherence of ions during cyclotron motion. However, this approach also presents the risk of coalescence of ion packets of similar frequencies. In general, ICR researchers in the past have lacked the tools necessary to distinguish or independently control dephasing and damping mechanisms for ICR signal loss. Nonetheless, the ability to impart greater phase coherence of ions in ICR measurements will allow significant advances in FTICR-MS research by improving the current understanding of ICR signal loss contributions of dephasing and damping of ion ensembles, increasing overall time-domain signal length, and possibly, resulting in more routine ultrahigh resolution measurements. The results presented here demonstrate the ability to employ a high density electron beam to perturb electric fields within the ICR cell during detection of cyclotron motion, in an approach we call electron-promoted ion coherence (EPIC). As such, EPIC reduces ICR signal degradation through loss of phase coherence, and much longer time-domain signals can be obtained. Our results demonstrate that time-domain signals can be extended by more than a factor of 4 with the implementation of EPIC, as

  9. Development of on-line laser power monitoring system

    Science.gov (United States)

    Ding, Chien-Fang; Lee, Meng-Shiou; Li, Kuan-Ming

    2016-03-01

    Since the laser was invented, laser has been applied in many fields such as material processing, communication, measurement, biomedical engineering, defense industries and etc. Laser power is an important parameter in laser material processing, i.e. laser cutting, and laser drilling. However, the laser power is easily affected by the environment temperature, we tend to monitor the laser power status, ensuring there is an effective material processing. Besides, the response time of current laser power meters is too long, they cannot measure laser power accurately in a short time. To be more precisely, we can know the status of laser power and help us to achieve an effective material processing at the same time. To monitor the laser power, this study utilize a CMOS (Complementary metal-oxide-semiconductor) camera to develop an on-line laser power monitoring system. The CMOS camera captures images of incident laser beam after it is split and attenuated by beam splitter and neutral density filter. By comparing the average brightness of the beam spots and measurement results from laser power meter, laser power can be estimated. Under continuous measuring mode, the average measuring error is about 3%, and the response time is at least 3.6 second shorter than thermopile power meters; under trigger measuring mode which enables the CMOS camera to synchronize with intermittent laser output, the average measuring error is less than 3%, and the shortest response time is 20 millisecond.

  10. Design of the Eelectron Cyclotron Resonance Heating Transmission System for HL-2A

    Institute of Scientific and Technical Information of China (English)

    周俊; 刘永

    2004-01-01

    HL-2A will be equipped with a 75 GHz/1 MW/1s electron cyclotron resonance heating (ECRH) system. The paper describes the design of the transmission system, which is made up of a transmission line, an equatorial launcher and a measureing system. The paper describes in detail the design of main components of the system such as, waveguides, ellipsoidal surface mirrors, chemical vapor (CVD) diamond window, steering mirror, and new directional coupler with a k-spectrometer. The newly-designed launcher can make the beam steer poloidally to deposit energy in different locations.

  11. Preliminary results of ion trajectory tracking in the acceleration region of the VINCY cyclotron

    Directory of Open Access Journals (Sweden)

    Ilić Anđelija Ž.

    2006-01-01

    Full Text Available In an accelerating region of a cyclotron, an ion makes a large number of turns; thus, its n the Runge-Kutta method of the fourth order with the adaptive time step has been developed. The accuracy requirement is simultaneously set on position and momentum calculation. Magnetic fields used as inputs, have been evaluated in terms of the radial fluctuations of the orbital frequency, i.e. their isochronisms. Ion trajectory tracking has been performed for the following four test beams: H-, H+3, 4He+, He+, and 40Ar6+.

  12. The Neutron Emission Ratio Observer NERO at the National Superconducting Cyclotron Laboratory

    Science.gov (United States)

    Pereira, Jorge; Hosmer, Paul; Lorusso, Giuseppe; Santi, Peter; Del Santo, Marcelo; Herlitzius, Clemens; Kratz, Karl-Ludwig; Montes, Fernando; Schatz, Hendrik; Schertz, Florian; Schnorrenberger, Linda; Smith, Karl; Wiescher, Michael

    2009-10-01

    The new neutron counter NERO (Neutron Emission Ratio Observer) was built at the National Superconducting Cyclotron Laboratory (NSCL) for measuring Pn values of neutron-rich nuclei produced as fast fragmentation beams. The design was motivated by the requirement of being coupled to the NSCL beta counting system, so that β-decay particles and neutrons emitted from implanted nuclei can be measured simultaneously, while keeping a high efficiency. The detector's performance and main features will be discussed, as well as recent measurements done at NSCL for astrophysical studies of the r-process.

  13. Fourier transform ion cyclotron resonance at SHIPTRAP. A non-destructive detection method for heavy radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Weber, C.; Dilling, J.; Kluge, H.J.; Marx, G.; Mukherjee, M.; Quint, W.; Rahaman, S.; Rodriguez, D.; Schoenfelder, J.; Sikler, G.; Tarisien, M. [GSI, Darmstadt (Germany)

    2003-07-01

    The physics program of the SHIPTRAP facility comprises mass spectrometry, nuclear spectroscopy, optical spectroscopy, and chemistry of fusion reaction produced nuclides and, especially, transeinsteinium elements. One of the major limitations to the experimental investigations is the low production rate for exotic nuclei. Detection schemes based on a destructive time-of-flight measurement lead to intolerably long beam times. An alternative is the Fourier transform-ion cyclotron resonance (FT-ICR) technique. It is suited for ion identification and mass measurements as well as for chemical studies. (orig.)

  14. Plasma diagnostics in TFTR using emission of cyclotron radiation at arbitrary frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Fidone, I.; Giruzzi, G.; Taylor, G.

    1995-07-01

    Emission of cyclotron radiation at arbitrary wave frequency for diagnostic purposes is discussed. It is shown that the radiation spectrum at arbitrary frequencies is more informative than the first few harmonics and it is suited for diagnosis of superthermal electrons without any {open_quotes}ad hoc{close_quotes} value of the wall reflection coefficient. Thermal radiation from TFTR is investigated and it is shown that the bulk and the tail of the electron momentum distribution during strong neutral beam injection is a Maxwellian with a single temperature in all ranges of electron energies.

  15. Fullerene-rare gas mixed plasmas in an electron cyclotron resonance ion source

    CERN Document Server

    Asaji, T; Uchida, T; Minezaki, H; Ishihara, S; Racz, R; Muramatsu, M; Biri, S; Kitagawa, A; Kato, Y; Yoshida, Y

    2015-01-01

    A synthesis technology of endohedral fullerenes such as Fe@C60 has developed with an electron cyclotron resonance (ECR) ion source. The production of N@C60 was reported. However, the yield was quite low, since most fullerene molecules were broken in the ECR plasma. We have adopted gas-mixing techniques in order to cool the plasma and then reduce fullerene dissociation. Mass spectra of ion beams extracted from fullerene-He, Ar or Xe mixed plasmas were observed with a Faraday cup. From the results, the He gas mixing technique is effective against fullerene destruction.

  16. On line routing per mobile phone

    DEFF Research Database (Denmark)

    Bieding, Thomas; Görtz, Simon; Klose, Andreas

    2009-01-01

    . Additionally it is of utmost importance that the employed communication system is suitable integrated with the firm’s enterprise application system and business processes. On basis of a case study, we describe in this paper a system that is cheap and easy to implement due to the use of simple mobile phones......On-line routing is concerned with building vehicle routes in an ongoing fashion in such a way that customer requests arriving dynamically in time are efficiently and effectively served. An indispensable prerequisite for applying on-line routing methods is mobile communication technology...

  17. Educational On-Line Gaming Propensity

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana; Kirchner, Kathrin

    2014-01-01

    Educational on-line games are promising for new generations of students who are grown up digital. Th e new generations of students are technology savvy and spend lots of time on the web and on social networks. Based on an exploratory study, this article investigates the factors that infl uence...... students’ willingness to participate in serious games for teaching/learning. Th is study investigates the relationship between students’ behavior on Facebook, Facebook games, and their attitude toward educational on-line games. Th e results of the study reveal that the early adopters of educational games...

  18. Application for the On-line Isotope Mass Separator ISOLDE Facility: the Mass Scan

    CERN Document Server

    Sánchez-Conejo, Jorge

    2003-01-01

    The purpose of the Mass Scan Application is to scan the mass of the ion beam that passes through the GPS (General Purpose Separator) on the On-Line Isotope Mass Separator ISOLDE facility. The application has been developed in Java, making use of the Java Development Kit 1.4 and the PS Java environment.

  19. Production of highly charged heavy ions by 18 GHz superconducting electron cyclotron resonance at Research Center for Nuclear Physics.

    Science.gov (United States)

    Yorita, Tetsuhiko; Hatanaka, Kichiji; Fukuda, Mitsuhiro; Kibayashi, Mitsuru; Morinobu, Shunpei; Okamura, Hiroyuki; Tamii, Atsushi

    2010-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source has been installed as a subject of the azimuthally varying field cyclotron upgrade project (K. Hatanaka et al., in Proceedings of the 17th International Conference on Cyclotrons and Their Applications, Tokyo, Japan, 18-22 October 2004, pp. 115-117), in order to increase beam currents and to extend the variety of ions. The production development of several ions has been performed since 2006 and some of them have already been used for user experiments [T. Yorita et al., Rev. Sci. Instrum. 79, 02A311 (2008)]. Further optimizations for each component such as the material of plasma electrode, material, and shape of bias probe and mirror field have been continued and more intense ion beams have been obtained for O, N, and Ar. For the purpose of obtaining highly charged Xe with several microamperes, the optimization of position and shape of plasma electrode and bias disk has also been done and highly charged Xe(32+) beam has been obtained successfully.

  20. Use of maze in cyclotron hoppers; Utilizacao de labirinto em bunker de ciclotron

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Fernando A.; Alves, Juliano S.; Fochesatto, Cintia; Cerioli, Luciane; Borges, Joao Alfredo; Gonzalez, Delfin; Silva, Daniel C., E-mail: fernandofernandes@biofarmaco.com.br [Delfin Farmacos e Derivados (Biofarmaco Marcadores Moleculares), Lauro de Freitas, BA (Brazil)

    2013-07-01

    Introduction: the increasing number of cyclotrons in Brazil due to constitutional amendment 49 /06 that enabled the production of radiopharmaceuticals with a short half - life by private companies. The radionuclides used for PET - CT require production centers near or within the diagnostic centers. In order to minimize maintenance and operating risks, gaining efficiency, our facility was the first in Brazil to use the access to a cyclotron bunker via maze, rather than armored door stopper type. Materials: the design calculations were based on the Monte Carlo method (MCNP5 - Monte Carlo N-Particletransportcode version 5). At the ends of the labyrinth are installed a door of polyethylene, for thermalization of neutrons, and other of wood for limiting access. Both legs of the maze have wall thickness of 100cm. In inspection Brazilian CNEN realize measures of dose rate for neutrons and gamma 9 points: 7 around the bunker, 1 over the bunker and 1 in the exhaust with the cyclotron operating with maximum load, double beam of 50uA for 2 hours. After commissioning were carried out around the bunker, the following measures: cumulative dose in three months with dosimeters for neutron rate dose with a gas proportional detector type filled with {sup 3}He and polyethylene neutron moderator and dose rate with a Geiger - Mueller detector for gamma radiation. Readings with neutron detectors were classified as background radiation and dose rates were always below the limits established in standard EN 3.01, and the calculation of the predicted regardless of the intensity of irradiation inside the bunker. Conclusion: the use of labyrinths as a way to access the bunkers cyclotron has been shown to be effective as the radiation shielding and efficient by allowing quick and easy access, virtually eliminating the maintenance.

  1. Benchmarking of codes for electron cyclotron heating and electron cyclotron current drive under ITER conditions

    NARCIS (Netherlands)

    Prater, R.; Farina, D.; Gribov, Y.; Harvey, R. W.; Ram, A. K.; Lin-Liu, Y. R.; Poli, E.; Smirnov, A. P.; Volpe, F.; Westerhof, E.; Zvonkovo, A.

    2008-01-01

    Optimal design and use of electron cyclotron heating requires that accurate and relatively quick computer codes be available for prediction of wave coupling, propagation, damping and current drive at realistic levels of EC power. To this end, a number of codes have been developed in laboratories wor

  2. Improvement of dose distribution in phantom by using epithermal neutron source based on the Be(p,n) reaction using a 30 MeV proton cyclotron accelerator.

    Science.gov (United States)

    Tanaka, H; Sakurai, Y; Suzuki, M; Takata, T; Masunaga, S; Kinashi, Y; Kashino, G; Liu, Y; Mitsumoto, T; Yajima, S; Tsutsui, H; Takada, M; Maruhashi, A; Ono, K

    2009-07-01

    In order to generate epithermal neutrons for boron neutron capture therapy (BNCT), we proposed the method of filtering and moderating fast neutrons, which are emitted from the reaction between a beryllium target and 30 MeV protons accelerated by a cyclotron, using an optimum moderator system composed of iron, lead, aluminum, calcium fluoride, and enriched (6)LiF ceramic filter. At present, the epithermal-neutron source is under construction since June 2008 at Kyoto University Research Reactor Institute. This system consists of a cyclotron to supply a proton beam of about 1 mA at 30 MeV, a beam transport system, a beam scanner system for heat reduction on the beryllium target, a target cooling system, a beam shaping assembly, and an irradiation bed for patients. In this article, an overview of the cyclotron-based neutron source (CBNS) and the properties of the treatment neutron beam optimized by using the MCNPX Monte Carlo code are presented. The distribution of the RBE (relative biological effectiveness) dose in a phantom shows that, assuming a (10)B concentration of 13 ppm for normal tissue, this beam could be employed to treat a patient with an irradiation time less than 30 min and a dose less than 12.5 Gy-eq to normal tissue. The CBNS might be an alternative to the reactor-based neutron sources for BNCT treatments.

  3. Particle-in-cell (PIC) simulations of beam instabilities in gyrotron beam tunnels

    Energy Technology Data Exchange (ETDEWEB)

    Tran, T.M.; Jost, G.; Appert, K.; Sauter, O. [Ecole Polytechnique Federale, Lausanne (Switzerland). Centre de Recherche en Physique des Plasma (CRPP); Wuthrich, S. [CRAY Research, PATP/PSE, Ecole Polytechnique Federale, Lausanne (Switzerland)

    1995-10-01

    Experimental observations seem to indicate that the beam velocity and energy spreads are larger than those calculated from the electron trajectory codes which do not take into account the effects of beam instabilities. On the other hand, parasitic oscillations of the beam with frequencies close to the electron cyclotron frequency {omega}{sub ce} have been observed experimentally, suggesting the possibility that instabilities can be excited in the beam tunnels and are responsible for the beam degradation. 2D electrostatic and electromagnetic time-dependent PIC codes have been developed to simulate the beam transport in the beam tunnel. The results of extensive parametric runs, using these codes (which were ported on the Cray T3D massively parallel computer), together with the role of the beam instabilities around {omega}{sub ce} on the beam degradation will be reported. (author) 2 figs., 9 refs.

  4. Electron cyclotron plasma startup in the GDT experiment

    Science.gov (United States)

    Yakovlev, D. V.; Shalashov, A. G.; Gospodchikov, E. D.; Solomakhin, A. L.; Savkin, V. Ya.; Bagryansky, P. A.

    2017-01-01

    We report on a new plasma startup scenario in the gas dynamic trap (GDT) magnetic mirror device. The primary 5 MW neutral beam injection (NBI) plasma heating system fires into a sufficiently dense plasma target (‘seed plasma’), which is commonly supplied by an arc plasma generator. In the reported experiments, a different approach to seed plasma generation is explored. One of the channels of the electron cyclotron resonance (ECR) heating system is used to ionize the neutral gas and build up the density of plasma to a level suitable for NBI capture. After a short transition of approximately 1 ms the discharge becomes essentially similar to a standard one initiated by the plasma gun. This paper presents the discharge scenario and experimental data on the seed plasma evolution during ECRH, along with the dependencies on incident microwave power, magnetic configuration and pressure of a neutral gas. The characteristics of the consequent high-power NBI discharge are studied and differences from the conventional scenario are discussed. A theoretical model describing the ECR breakdown and the seed plasma accumulation in a large-scale mirror trap is developed on the basis of the GDT experiment.

  5. Electron-cyclotron plasma startup in the GDT experiment

    CERN Document Server

    Yakovlev, D V; Gospodchikov, E D; Solomakhin, A L; Savkin, V Ya; Bagryansky, P A

    2016-01-01

    The paper reports on a new plasma startup scenario in the Gas Dynamic Trap (GDT) magnetic mirror device. The primary 5 MW neutral beam injection (NBI) plasma heating system fires into a sufficiently dense plasma target ("seed plasma"), which is commonly supplied by an arc plasma generator. In the reported experiments, a different approach to seed plasma generation is explored. One of the channels of the electron cyclotron resonance (ECR) heating system is used to ionize the neutral gas and build up the density of plasma to a level suitable for NBI capture. After a short transition (about 1 ms) the discharge becomes essentially similar to a standard one initiated by the plasma gun. The paper presents the discharge scenario and experimental data on the seed plasma evolution during ECR heating, along with the dependencies on incident microwave power, magnetic configuration and pressure of a neutral gas. The characteristics of consequent high-power NBI discharge are studied and differences to the conventional sce...

  6. Current drive by electron cyclotron waves in stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Castejon, F.; Alejaldre, C.; Coarasa, J. A.

    1992-07-01

    In this paper we propose a method to estimate the induced current by Electron Cyclotron waves fast enough, from the numerical point of view, to be included in a ray-tracing code, and yet accounting for the complicated geometry of stellarators. Since trapped particle effects are particularly important in this Current Drive method and in stellarator magnetic configuration, they are considered by the modification they introduce in the current drive efficiency. Basically, the method consists of integrating the Fisch and Boozer relativistic efficiency, corrected with the effect of trapped particles, times the absorbed power per momentum interval. This one is calculated for a Maxwellian distribution function, assuming a nearly linear regime. The influence of impurities and of species which are not protons is studied, calculating the efficiency for plasmas with Zeff) - Finally, a numerical analysis particularized to TJ-II stellarator is presented. The absorbed power density is calculated by the ray tracing code RAYS, taking into account the actual microwave beam structure. (Author) 23 refs.

  7. ON-LINE DOCUMENTS CONTENT MANAGEMENT

    Directory of Open Access Journals (Sweden)

    VASILESCU RAMONA VIOLETA

    2010-05-01

    Full Text Available This paper outlines the steps and technologies used in developing an on-line application server with many desktop clients, and with high power processing for a wide range of input documents to obtain searchable documents on the highest portability standards, PDF and PDF /A.

  8. Microwave Absorption in Electron Cyclotron Resonance Plasma

    Institute of Scientific and Technical Information of China (English)

    LIU Ming-Hai; HU Xi-Wei; WU Qin-Chong; YU Guo-Yang

    2000-01-01

    The microwave power absorption in electron cyclotron resonance plasma reactor was investigated with a twodimensional hybrid-code. Simulation results indicated that there are two typical power deposition profiles over the entire parameter region: (1) microwave power deposition peaks on the axis and decreases in radial direction,(2) microwave power deposition has its maximum at some radial position, i.e., a hollow distribution. The spatial distribution of electron temperature resembles always to the microwave power absorption profile. The dependence of plasma parameter on the gas pressure is discussed also.

  9. Relativistic Cyclotron Instability in Anisotropic Plasmas

    Science.gov (United States)

    López, Rodrigo A.; Moya, Pablo S.; Navarro, Roberto E.; Araneda, Jaime A.; Muñoz, Víctor; Viñas, Adolfo F.; Alejandro Valdivia, J.

    2016-11-01

    A sufficiently large temperature anisotropy can sometimes drive various types of electromagnetic plasma micro-instabilities, which can play an important role in the dynamics of relativistic pair plasmas in space, astrophysics, and laboratory environments. Here, we provide a detailed description of the cyclotron instability of parallel propagating electromagnetic waves in relativistic pair plasmas on the basis of a relativistic anisotropic distribution function. Using plasma kinetic theory and particle-in-cell simulations, we study the influence of the relativistic temperature and the temperature anisotropy on the collective and noncollective modes of these plasmas. Growth rates and dispersion curves from the linear theory show a good agreement with simulations results.

  10. Electron cyclotron emission diagnostics on KSTAR tokamak.

    Science.gov (United States)

    Jeong, S H; Lee, K D; Kogi, Y; Kawahata, K; Nagayama, Y; Mase, A; Kwon, M

    2010-10-01

    A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.

  11. Electron cyclotron emission diagnostics on KSTAR tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, S. H. [Korea Atomic Energy Research Institute, 1045 Daedeokdaero, Daejeon 305-353 (Korea, Republic of); Lee, K. D.; Kwon, M. [National Fusion Research Institute, 113 Gwahangno, Daejeon 305-333 (Korea, Republic of); Kogi, Y. [Fukuoka Institute of Technology, Higashiku, Fukuoka 811-0295 (Japan); Kawahata, K.; Nagayama, Y. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Mase, A. [KASTEC, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan)

    2010-10-15

    A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.

  12. Electron Cyclotron Resonance Heating of a High-Density Plasma

    DEFF Research Database (Denmark)

    Hansen, F. Ramskov

    1986-01-01

    Various schemes for electron cyclotron resonance heating of tokamak plasmas with the ratio of electron plasma frequency to electron cyclotron frequency, "»pe/^ce* larger than 1 on axis, are investigated. In particular, a mode conversion scheme is investigated using ordinary waves at the fundamental...

  13. The next generation of electron cyclotron emission imaging diagnostics (invited)

    NARCIS (Netherlands)

    Zhang, P.; Domier, C.W.; Liang, T.; Kong, X.; Tobias, B.; Shen, Z.; N C Luhmann Jr.,; Park, H.; Classen, I.G.J.; van de Pol, M.J.; Donne, A. J. H.; R. Jaspers,

    2008-01-01

    A 128 channel two-dimensional electron cyclotron emission imaging system collects time-resolved 16x8 images of T-e profiles and fluctuations on the TEXTOR tokamak. Electron cyclotron emission imaging (ECEI) is undergoing significant changes which promise to revolutionize and extend its capabilities

  14. The next generation of electron cyclotron emission imaging diagnostics (invited)

    NARCIS (Netherlands)

    Zhang, P.; Domier, C.W.; Liang, T.; Kong, X.; Tobias, B.; Shen, Z.; N C Luhmann Jr.,; Park, H.; Classen, I.G.J.; van de Pol, M.J.; Donne, A. J. H.; R. Jaspers,

    2008-01-01

    A 128 channel two-dimensional electron cyclotron emission imaging system collects time-resolved 16x8 images of T-e profiles and fluctuations on the TEXTOR tokamak. Electron cyclotron emission imaging (ECEI) is undergoing significant changes which promise to revolutionize and extend its capabilities

  15. On-Line Adaptive Radiation Therapy: Feasibility and Clinical Study

    Directory of Open Access Journals (Sweden)

    Taoran Li

    2010-01-01

    Full Text Available The purpose of this paper is to evaluate the feasibility and clinical dosimetric benefit of an on-line, that is, with the patient in the treatment position, Adaptive Radiation Therapy (ART system for prostate cancer treatment based on daily cone-beam CT imaging and fast volumetric reoptimization of treatment plans. A fast intensity-modulated radiotherapy (IMRT plan reoptimization algorithm is implemented and evaluated with clinical cases. The quality of these adapted plans is compared to the corresponding new plans generated by an experienced planner using a commercial treatment planning system and also evaluated by an in-house developed tool estimating achievable dose-volume histograms (DVHs based on a database of existing treatment plans. In addition, a clinical implementation scheme for ART is designed and evaluated using clinical cases for its dosimetric qualities and efficiency.

  16. A versatile apparatus for on-line emission channeling experiments

    CERN Document Server

    da Silva, Manuel Ribeiro; Correia, João Guilherme; Amorim, Lígia Marina; Pereira, Lino Miguel da Costa

    2013-01-01

    The concept and functionality of an apparatus dedicated to emission channeling experiments using short-lived isotopes on-line at ISOLDE/CERN is described. The setup is assembled in two functional blocks - (a) base stand including beam collimation, implantation and measurement chamber, cryogenic extension, and vacuum control system and - (b) Panmure goniometer extension including maneuvering cradle and sample heating furnace. This setup allows for in situ implantation and sample analysis in the as-implanted state and upon cooling down to 50 K and during annealing up to 1200 K. The functionality of the setup will be illustrated with the example of establishing the lattice location of $^{56}$Mn probes implanted into GaAs.

  17. Cyclotron resonance effects on stochastic acceleration of light ionospheric ions

    Science.gov (United States)

    Singh, N.; Schunk, R. W.; Sojka, J. J.

    1982-01-01

    The production of energetic ions with conical pitch angle distributions along the auroral field lines is a subject of considerable current interest. There are several theoretical treatments showing the acceleration (heating) of the ions by ion cyclotron waves. The quasi-linear theory predicts no acceleration when the ions are nonresonant. In the present investigation, it is demonstrated that the cyclotron resonances are not crucial for the transverse acceleration of ions by ion cyclotron waves. It is found that transverse energization of ionospheric ions, such as He(+), He(++), O(++), and O(+), is possible by an Electrostatic Hydrogen Cyclotron (EHC) wave even in the absence of cyclotron resonance. The mechanism of acceleration is the nonresonant stochastic heating. However, when there are resonant ions both the total energy gain and the number of accelerated ions increase with increasing parallel wave number.

  18. Performance Estimation for the Beam Scraper of CYCIAE-100

    Institute of Scientific and Technical Information of China (English)

    YANG; Jian-jun; SONG; Guo-fang; ZHONG; Jun-qing

    2013-01-01

    In the central region of high intensity cyclotron,the beam halo particles can be wiped away by the beam scraper.Calculation shows if the scraper is installed at the region corresponding to the particle energy lower than 5 MeV,it is capable to collect the beam halo particles which might otherwise be lost at the high energy region;Meanwhile,it will not generate a mass of secondary neutrons,and therefore lessen

  19. Electron cyclotron maser emission mode coupling to the z-mode on a longitudinal density gradient in the context of solar type III bursts

    CERN Document Server

    Pechhacker, Roman

    2012-01-01

    A beam of super-thermal, hot electrons was injected into maxwellian plasma with a density gradient along a magnetic field line. 1.5D particle-in-cell simulations were carried out which established that the EM emission is produced by the perpendicular component of the beam injection momentum. The beam has a positive slope in the distribution function in perpendicular momentum phase space, which is the characteristic feature of a cyclotron maser. The cyclotron maser in the overdense plasma generates emission at the electron cyclotron frequency. The frequencies of generated waves were too low to propagate away from the injection region, hence the wavelet transform shows a pulsating wave generation and decay process. The intensity pulsation frequency is twice the relativistic cyclotron frequency. Eventually, a stable wave packet formed and could mode couple on the density gradient to reach frequencies of the order of the plasma frequency, that allowed for propagation. The emitted wave is likely to be a z-mode wav...

  20. Characterization of the proton beam from an IBA Cyclone 18/9 with radiochromic film EBT2

    Energy Technology Data Exchange (ETDEWEB)

    Sansaloni, F.; Lagares, J. I.; Arce, P.; Llop, J.; Perez, J. M. [Medical Applications Unit, Technology Department, CIEMAT, Madrid (Spain); Radiochemistry Department, Molecular Imaging unit, CIC-biomaGUNE, San Sebastian (Spain); Technology Department, CIEMAT (Spain)

    2012-12-19

    The use of radiochromic films is widespread in different areas of medical physics like radiotherapy and hadrontherapy; however, radiochromic films have been scarcely used in the characterization of proton or deuteron beams generated in biomedical cyclotrons. In this paper the radiochromic film EBT2 was used to study the beam size and the proton beam energy of an IBA Cyclone 18/9 cyclotron. The results indicate that the beam size can be easily measured at a very low expense; however, an accurate determination of the beam energy might require the implementation of certain experimental improvements.

  1. Characterization of the proton beam from an IBA Cyclone 18/9 with radiochromic film EBT2

    Science.gov (United States)

    Sansaloni, F.; Lagares, J. I.; Arce, P.; Llop, J.; Perez, J. M.

    2012-12-01

    The use of radiochromic films is widespread in different areas of medical physics like radiotherapy and hadrontherapy; however, radiochromic films have been scarcely used in the characterization of proton or deuteron beams generated in biomedical cyclotrons. In this paper the radiochromic film EBT2 was used to study the beam size and the proton beam energy of an IBA Cyclone 18/9 cyclotron. The results indicate that the beam size can be easily measured at a very low expense; however, an accurate determination of the beam energy might require the implementation of certain experimental improvements.

  2. Cyclotron and linac production of Ac-225.

    Science.gov (United States)

    Melville, Graeme; Allen, Barry J

    2009-04-01

    Radium needles that were once implanted into tumours as a cancer treatment are now obsolete and constitute a radioactive waste problem, as their half-life is 1600 years. The reduction of radium by photonuclear transmutation by bombarding Ra-226 with high-energy photons from a medical linear accelerator (linac) has been investigated. A linac dose of 2800 Gy produced about 2.4 MBq (64 microCi) of Ra-225, which decays to Ac-225 and can then be used for 'Targeted Alpha Therapy' (TAT) of cancer. This result, while consistent with theoretical calculations, is far too low to be of practical use unless much larger quantities of radium are irradiated. The increasing application of Ac-225 for cancer therapy indicates the potential need for its increased production and availability. This paper investigates the possibility of producing of Ac-225 in commercial quantities, which could potentially reduce obsolete radioactive material and displace the need for expensive importation of Ac-225 from the USA and Russia in the years ahead. Scaled up production of Ac-225 could theoretically be achieved by the use of a high current cyclotron or linac. Production specifications are determined for a linac in terms of current, pulse length and frequency, as well as an examination of other factors such as radiation issues and radionuclei separation. Yields are compared with those calculated for the Australian National Cyclotron in Sydney.

  3. Resonant cyclotron scattering in magnetars' emission

    CERN Document Server

    Rea, Nanda; Turolla, Roberto; Lyutikov, Maxim; Gotz, Diego

    2008-01-01

    We present a systematic application of a resonant cyclotron scattering (RCS) model to a comprehensive set of magnetars, including canonical and transient anomalous X-ray pulsars, and soft gamma repeaters. In this scenario, non-thermal magnetar spectra in the soft X-rays (i.e. below ~10keV) result from resonant cyclotron scattering of the thermal surface emission by hot magnetospheric plasma. We find that this model can successfully account for the X-ray emission of magnetars, while using the same number of free parameters than the commonly used empirical blackbody plus power-law model. We find that the entire class of sources is characterized by magnetospheric plasma with similar properties, in particular the optical depth is in a quite narrow range (tau_{res} ~1-2). This leads to an estimate of the magnetospheric electron densities at the resonance n_e ~ 1.5x10^{13} tau_{res} cm^{-3}, which is 3 orders of magnitudes greater than n_{GJ}, the Goldreich-Julian electron density for pulsar magnetospheres. The inf...

  4. High energy fast neutrons from the Harwell variable energy cyclotron. I. Physical characteristics.

    Science.gov (United States)

    Goodhead, D T; Berry, R J; Bance, D A; Gray, P; Stedeford, J B

    1977-10-01

    A high energy fast neutron beam potentially suitable for radiotherapy was built at the Harwell variable energy cyclotron. The beam line is described and results are given of physical measurements on the fast neutron beams produced by 42 MeV deuterons on thick (4 mm) and thin (2 mm) beryllium targets. With 20 muA beam current the entrance dose rate in a phantom 150 cm from the target was about 130 rad min-1 with the thick target and about 60 rad min-1 with the thin target. Therefore, it is possible to use both the thin target and the relatively large target-skin distance of 150 cm to improve depth dose for radiotherapy or radiobiology. With this arrangement the dose rate decreased to 50% at depths in the phantom of 11.3-15.4 cm, depending on the field size. The use of primarily hydrogenous materials for shielding and collimation provided beam edge definition similar to that of 60Co teletherapy units, and off-axis radiation levels of approximately 1% which compare favorably with 14 MeV deuteron-tritium generators. The copper backing of the thin target became highly radioactive and an alterative material may be preferable. Biologic characteristics of the beam are described in a companion paper.

  5. Possible Scheme of the Analyzing Part of a Cyclotron Injection Beamline with Higher Energy

    CERN Document Server

    Kazarinov, Nikolay; Stetson, Jeffry W

    2005-01-01

    The ion beam produced with an ECR ion source (ECRIS) with an extraction voltage of 30 kV may be additionally accelerated using a negative voltage of -30 kV applied to the last electrode of the extraction system, connected to the beamline biased to the same -30 kV potential. In this way the kinetic energy of the beam is increased to 60 keV/q, decreasing to half the space charge effect on the beam emittance. Using a large gap analyzing magnet placed right after the ECRIS and no focusing element, the transmission is still close to 100%. The voltage on the beamline must be kept constant from the ECRIS till the image focal plane of the analyzing magnet where the full separation of the beam charge states is achieved. An insulator break separates the biased beamline from the downstream section, which is at zero potential. Passing through this section of the beamline, the ion beam is decelerated to 30 keV/q, the energy necessary for the injection in the cyclotron. In order to prevent the increase of the beam divergen...

  6. Roles of Fast-Cyclotron and Alfven-Cyclotron Waves for the Multi-Ion Solar Wind

    CERN Document Server

    Xiong, Ming

    2012-01-01

    Using linear Vlasov theory of plasma waves and quasi-linear theory of resonant wave-particle interaction, the dispersion relations and the electromagnetic field fluctuations of fast and Alfven waves are studied for a low-beta multi-ion plasma in the inner corona. Their probable roles in heating and accelerating the solar wind via Landau and cyclotron resonances are quantified. We assume that (1) low-frequency Alfven and fast waves have the same spectral shape and the same amplitude of power spectral density; (2) these waves eventually reach ion cyclotron frequencies due to a turbulence cascade; (3) kinetic wave-particle interaction powers the solar wind. The existence of alpha particles in a dominant proton/electron plasma can trigger linear mode conversion between oblique fast-whistler and hybrid alpha-proton cyclotron waves. The fast-cyclotron waves undergo both alpha and proton cyclotron resonances. The alpha cyclotron resonance in fast-cyclotron waves is much stronger than that in Alfven-cyclotron waves. ...

  7. Beam induced electron cloud resonances in dipole magnetic fields

    Science.gov (United States)

    Calvey, J. R.; Hartung, W.; Makita, J.; Venturini, M.

    2016-07-01

    The buildup of low energy electrons in an accelerator, known as electron cloud, can be severely detrimental to machine performance. Under certain beam conditions, the beam can become resonant with the cloud dynamics, accelerating the buildup of electrons. This paper will examine two such effects: multipacting resonances, in which the cloud development time is resonant with the bunch spacing, and cyclotron resonances, in which the cyclotron period of electrons in a magnetic field is a multiple of bunch spacing. Both resonances have been studied directly in dipole fields using retarding field analyzers installed in the Cornell Electron Storage Ring. These measurements are supported by both analytical models and computer simulations.

  8. Feasibility study on epithermal neutron field for cyclotron-based boron neutron capture therapy.

    Science.gov (United States)

    Yonai, Shunsuke; Aoki, Takao; Nakamura, Takashi; Yashima, Hiroshi; Baba, Mamoru; Yokobori, Hitoshi; Tahara, Yoshihisa

    2003-08-01

    To realize the accelerator-based boron neutron capture therapy (BNCT) at the Cyclotron and Radioisotope Center of Tohoku University, the feasibility of a cyclotron-based BNCT was evaluated. This study focuses on optimizing the epithermal neutron field with an energy spectrum and intensity suitable for BNCT for various combinations of neutron-producing reactions and moderator materials. Neutrons emitted at 90 degrees from a thick (stopping-length) Ta target, bombarded by 50 MeV protons of 300 microA beam current, were selected as a neutron source, based on the measurement of angular distributions and neutron energy spectra. As assembly composed of iron, AlF3/Al/6LiF, and lead was chosen as moderators, based on the simulation trials using the MCNPX code. The depth dose distributions in a cylindrical phantom, calculated with the MCNPX code, showed that, within 1 h of therapeutic time, the best moderator assembly, which is 30-cm-thick iron, 39-cm-thick AlF3/Al/6LiF, and 1-cm-thick lead, provides an epithermal neutron flux of 0.7 x 10(9) [n cm(-2) s(-1)]. This results in a tumor dose of 20.9 Gy-eq at a depth of 8 cm in the phantom, which is 6.4 Gy-eq higher than that of the Brookhaven Medical Research Reactor at the equivalent condition of maximum normal tissue tolerance. The beam power of the cyclotron is 15 kW, which is much lower than other accelerator-based BNCT proposals.

  9. Beam simulation studies of ECR beam extraction and low energy beam transport for FRIB.

    Science.gov (United States)

    Ren, Haitao; Pozdeyev, Eduard; Lund, Steven M; Machicoane, Guillaume; Wu, Xiaoyu; Morgan, Glenn

    2016-02-01

    To meet the beam power requirements of 400 kW at the fragmentation target for facility for Rare Isotope Beams (FRIB), simultaneous acceleration of two-charge states should be used for heavier ions. These intense multi-charged ion beams will be produced by a 28 GHz electron cyclotron resonance (ECR) ion source at a high voltage of 35 kV. After extraction, the ion beam will be pre-accelerated to 12 keV/u with a 50 kV platform, transported down to an achromatic charge state selection (CSS) system followed by a vertical transport line, and then injected into a radio frequency quadrupole accelerator. The TRACK code developed at ANL is used to perform the simulations of the ECR beam extraction and low energy beam transport for FRIB. In this study, we include the magnetic field of ECR ion source into simulations. Different initial beam conditions as well as different space charge neutralization levels are tested for the ECR beamline. The beam loss in CSS system and the corresponding protective measures are discussed. The detailed results about the beam dynamic simulation and beam loss in CSS system will be presented in this paper.

  10. Educational On-Line Gaming Propensity

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana; Kirchner, Kathrin

    2014-01-01

    Educational on-line games are promising for new generations of students who are grown up digital. Th e new generations of students are technology savvy and spend lots of time on the web and on social networks. Based on an exploratory study, this article investigates the factors that infl uence...... students’ willingness to participate in serious games for teaching/learning. Th is study investigates the relationship between students’ behavior on Facebook, Facebook games, and their attitude toward educational on-line games. Th e results of the study reveal that the early adopters of educational games...... are likely to be students, who are young, have only a few Facebook connections, who currently play Facebook game(s). Furthermore, the study emphasizes that there may be differences between students coming from various countries....

  11. New Trends in on-line Marketing

    OpenAIRE

    Palkovič, Lukáš

    2011-01-01

    This bachelor thesis deals with new trend of internet marketing, it focuses especially on viral marketing. The theoretical part charasterizes the process of viral campaigns, furthermore deals with the components and aspects of on-line environment. Another separated chapter presents social networks, their place in viral marketing and at last but not least the viral video making process. The practical part contains different analyses of specific viral campaigns. The next and equally the last pa...

  12. Connecting to On-line Data

    Science.gov (United States)

    Eichhorn, G.; Astrophysics Datacenter Executive Committee (ADEC)

    2004-05-01

    The Astrophysics Datacenter Executive Committee (ADEC) is coordinating the development of a system to facilitate the linking to on-line data. This system has three components: 1. Unique dataset identifiers. 2. A verification system for identifiers. 3. Permanent links to on-line data sets. 1. The ADEC has agreed on a naming scheme for data sets that allows for the unique identification of any data set. The ADEC data centers will clearly mark their data with these identifiers to allow the generation of links to these data. 2. Each data center has a utility that can check whether a data set identifier is a valid identifier at that center. A central verifier allows third parties access to these individual verifiers through a single portal. 3. The central verifier also provides permanent links to data sets through a central link forwarding system. This makes it possible to move data sets between data centers while maintaining the permanent links. The ADEC plans to first use this system to implement the linking from the literature to on-line data in a collaboration with the AAS and the University of Chicago Press for the AAS journals.

  13. The development of a room temperature electron cyclotron resonance ion source (Lanzhou electron cyclotron resonance ion source No. 4) with evaporative cooling technology at Institute of Modern Physics

    Energy Technology Data Exchange (ETDEWEB)

    Lu, W., E-mail: luwang@impcas.ac.cn; Sun, L. T.; Qian, C.; Feng, Y. C.; Ma, H. Y.; Zhang, X. Z.; Ma, B. H.; Zhao, H. W. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 73000 (China); Guo, J. W.; Fang, X.; Yang, Y. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 73000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Xiong, B.; Guo, S. Q.; Ruan, L. [Institute of Electrical Engineering, CAS, Beijing 100190 (China)

    2015-04-15

    LECR4 (Lanzhou electron cyclotron resonance ion source No. 4) has been successfully constructed at IMP and has also been connected with the Low Energy Beam Transport (LEBT) and Radio Frequency Quadrupole (RFQ) systems. These source magnet coils are cooled through evaporative cooling technology, which is the first attempt with an ECR ion source in the world. The maximum mirror field is 2.5 T (with iron plug) and the effective plasma chamber volume is 1.2 l. It was designed to be operated at 18 GHz and aimed to produce intense multiple charge state heavy ion beams for the linear injector project SSC-Linac at IMP. In February 2014, the first analyzed beam at 18 GHz was extracted. During about three months’ commissioning, some outstanding results have been achieved, such as 1.97 emA of O{sup 6+}, 1.7 emA of Ar{sup 8+}, 1.07 emA of Ar{sup 9+}, and 118 euA of Bi{sup 28+}. The source has also successfully delivered O{sup 5+} and Ar{sup 8+} ion beams for RFQ commissioning in April 2014. This paper will give a brief overview of the design of LECR4. Then, the latest results of this source at 18 GHz will be presented.

  14. The development of a room temperature electron cyclotron resonance ion source (Lanzhou electron cyclotron resonance ion source No. 4) with evaporative cooling technology at Institute of Modern Physics.

    Science.gov (United States)

    Lu, W; Sun, L T; Qian, C; Guo, J W; Fang, X; Feng, Y C; Yang, Y; Ma, H Y; Zhang, X Z; Ma, B H; Xiong, B; Guo, S Q; Ruan, L; Zhao, H W

    2015-04-01

    LECR4 (Lanzhou electron cyclotron resonance ion source No. 4) has been successfully constructed at IMP and has also been connected with the Low Energy Beam Transport (LEBT) and Radio Frequency Quadrupole (RFQ) systems. These source magnet coils are cooled through evaporative cooling technology, which is the first attempt with an ECR ion source in the world. The maximum mirror field is 2.5 T (with iron plug) and the effective plasma chamber volume is 1.2 l. It was designed to be operated at 18 GHz and aimed to produce intense multiple charge state heavy ion beams for the linear injector project SSC-Linac at IMP. In February 2014, the first analyzed beam at 18 GHz was extracted. During about three months' commissioning, some outstanding results have been achieved, such as 1.97 emA of O(6+), 1.7 emA of Ar(8+), 1.07 emA of Ar(9+), and 118 euA of Bi(28+). The source has also successfully delivered O(5+) and Ar(8+) ion beams for RFQ commissioning in April 2014. This paper will give a brief overview of the design of LECR4. Then, the latest results of this source at 18 GHz will be presented.

  15. Progress in research, April 1, 1992--March 31, 1993, Texas A and M University Cyclotron Institute

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-07-01

    This Institute annual report for the period 1 April 1992--31 March 1993 covers a period which has seen the initial runs of three new spectrometers which constitute a major portion of the new detection capabilities developed for this facility. These devices are the Proton Spectrometer (PSP), the Mass Achromat Recoil Mass Spectrometer (MARS), and the Multipole dipole Multipole (MDM) Particle Spectrometer. These devices are now available to pursue the studies of Gamow Teller states, reactions of astrophysical interest, and giant resonance studies for which they were constructed, as well as for other experiments. A beam analysis system which will deliver high resolution beams to the MDM spectrometer is currently under construction. With the completion of these spectrometer projects, the facility emphasis is now focused on the development of the full capabilities of the K500 cyclotron and on the research program. During the report period, the ECR-K500 cyclotron combination operated 5,849 hours. Theoretical work reported in this document ranges from nuclear structure calculations using the IBM-2 model to calculations of kaon production and the in-medium properties of the rho and phi mesons, the latter as a probe of the QCD phase transition. Nuclear dynamics and exotic shapes and fragmentation modes of hot nuclei are also addressed. In atomic physics, new measurements of x-ray emission from highly ionized ions, of molecular dissociation and of surface interactions are reported.

  16. Major results of the electron cyclotron heating experiment in the PDX tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Hsuan, H.; Bol, K.; Bowen, N.; Boyd, D.; Cavallo, A.; Dimits, A.; Doane, J.; Elder, G.; Goldman, M.; Grek, B.

    1984-07-01

    Electron Cyclotron Heating (ECH) experiments on PDX have been carried out with two 60 GHz pulsed gyrotrons each yielding up to approximately 100 kW. The ECH system used two waveguide runs each about 30 meters long. One run included 5 bends and the other, 7 bends. Predetermined waveguide modes were transmitted. The electron cyclotron waves were launched in narrow beams from both the high field and the low field sides of the plasma torus. The major new physics results are: (1) efficient central electron heating for both ohmic and neutral beam heated target plasmas; (2) alteration of MHD behavior using ECH; (3) identification of the trapped electron population with ECH; and (4) signature of velocity-space time evolution during ECH. In the best heating results obtained, Thomson scattering data indicated a central temperature increase from less than or equal to 1.5 keV to greater than or equal to 2.5 keV. This occurred with an average density of about 10/sup 13/ cm/sup -3/ and approximately 80 kW outside-launch ordinary-mode heating.

  17. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Yushi, E-mail: kato@eei.eng.osaka-u.ac.jp; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu [Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2016-02-15

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  18. Developing laser ablation in an electron cyclotron resonance ion source for actinide detection with AMS

    Energy Technology Data Exchange (ETDEWEB)

    Bauder, W. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Pardo, R.C.; Kondev, F.G.; Kondrashev, S.; Nair, C.; Nusair, O. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Palchan, T. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel); Scott, R.; Seweryniak, D.; Vondrasek, R. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Collon, P. [University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Paul, M. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel)

    2015-10-15

    A laser ablation material injection system has been developed at the ATLAS electron cyclotron resonance (ECR) ion source for use in accelerator mass spectrometry experiments. Beam production with laser ablation initially suffered from instabilities due to fluctuations in laser energy and cratering on the sample surface by the laser. However, these instabilities were rectified by applying feedback correction for the laser energy and rastering the laser across the sample surface. An initial experiment successfully produced and accelerated low intensity actinide beams with up to 1000 counts per second. With continued development, laser ablation shows promise as an alternative material injection scheme for ECR ion sources and may help substantially reduce cross talk in the source.

  19. Control system renewal for efficient operation in RIKEN 18 GHz electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, A., E-mail: a-uchi@riken.jp; Ozeki, K.; Higurashi, Y.; Kidera, M.; Komiyama, M.; Nakagawa, T. [RIKEN Nishina Center, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)

    2016-02-15

    A RIKEN 18 GHz electron cyclotron resonance ion source (18 GHz ECRIS) is used as an external ion source at the Radioactive Ion Beam Factory (RIBF) accelerator complex to produce an intense beam of medium-mass heavy ions (e.g., Ca and Ar). In most components that comprise the RIBF, the control systems (CSs) are integrated by the Experimental Physics and Industrial Control System (EPICS). On the other hand, a non-EPICS-based system has hardwired controllers, and it is used in the 18 GHz ECRIS CS as an independent system. In terms of efficient and effective operation, the 18 GHz ECRIS CS as well as the RIBF CS should be renewed using EPICS. Therefore, we constructed an 18 GHz ECRIS CS by using programmable logic controllers with embedded EPICS technology. In the renewed system, an operational log system was developed as a new feature, for supporting of the 18 GHz ECRIS operation.

  20. A Proton-Cyclotron Wave Storm Generated by Unstable Proton Distribution Functions in the Solar Wind

    Science.gov (United States)

    Wicks, R. T.; Alexander, R. L.; Stevens, M.; Wilson, L. B., III; Moya, P. S.; Vinas, A.; Jian, L. K.; Roberts, D. A.; O’Modhrain, S.; Gilbert, J. A.; Zurbuchen, T. H.

    2016-01-01

    We use audification of 0.092 seconds cadence magnetometer data from the Wind spacecraft to identify waves with amplitudes greater than 0.1 nanoteslas near the ion gyrofrequency (approximately 0.1 hertz) with duration longer than 1 hour during 2008. We present one of the most common types of event for a case study and find it to be a proton-cyclotron wave storm, coinciding with highly radial magnetic field and a suprathermal proton beam close in density to the core distribution itself. Using linear Vlasov analysis, we conclude that the long-duration, large-amplitude waves are generated by the instability of the proton distribution function. The origin of the beam is unknown, but the radial field period is found in the trailing edge of a fast solar wind stream and resembles other events thought to be caused by magnetic field footpoint motion or interchange reconnection between coronal holes and closed field lines in the corona.

  1. Electromagnetic ion cyclotron waves observed near the oxygen cyclotron frequency by ISEE 1 and 2

    Science.gov (United States)

    Fraser, B. J.; Samson, J. C.; Hu, Y. D.; Mcpherron, R. L.; Russell, C. T.

    1992-01-01

    The first results of observations of ion cyclotron waves by the elliptically orbiting ISEE 1 and 2 pair of spacecraft are reported. The most intense waves (8 nT) were observed in the outer plasmasphere where convection drift velocities were largest and the Alfven velocity was a minimum. Wave polarization is predominantly left-handed with propagation almost parallel to the ambient magnetic field, and the spectral slot and polarization reversal predicted by cold plasma propagation theory are identified in the wave data. Computations of the experimental wave spectra during the passage through the plasmapause show that the spectral slots relate to the local plasma parameters, possibly suggesting an ion cyclotron wave growth source near the spacecraft. A regular wave packet structure seen over the first 30 min of the event is attributed to the modulation of this energy source by the Pc 5 waves seen at the same time.

  2. Cyclotrons and positron emission tomography radiopharmaceuticals for clinical imaging.

    Science.gov (United States)

    Saha, G B; MacIntyre, W J; Go, R T

    1992-07-01

    Positron emission tomography (PET) requires positron-emitting radionuclides that emit 511-keV photons detectable by PET imagers. Positron-emitting radionuclides are commonly produced in charged particle accelerators, eg, linear accelerators or cyclotrons. The most widely available radiopharmaceuticals for PET imaging are carbon-11-, nitrogen-13-, and oxygen-15-labeled compounds, many of which, either in their normal state or incorporated in other compounds, serve as physiological tracers. Other useful PET radiopharmaceuticals include fluorine-18-, bromine-75-, gallium-68 (68Ga)-, rubidium-82 (82Rb)-, and copper-62 (62Cu)-labeled compounds. Many positron emitters have short half-lives and thus require on-site cyclotrons for application, and others (68Ga, 82Rb, and 62Cu) are available from radionuclides generators using relatively long-lived parent radionuclides. This review is divided into two sections: cyclotrons and PET radiopharmaceuticals for clinical imaging. In the cyclotron section, the principle of operation of the cyclotron, types of cyclotrons, medical cyclotrons, and production of radionuclides are discussed. In the section on PET radiopharmaceuticals, the synthesis and clinical use of PET radiopharmaceuticals are described.

  3. The Dispersion Relations and Instability Thresholds of Oblique Plasma Modes in the Presence of an Ion Beam

    CERN Document Server

    Verscharen, Daniel

    2012-01-01

    An ion beam can destabilize Alfv\\'en/ion-cyclotron waves and magnetosonic/whistler waves if the beam speed is sufficiently large. Numerical solutions of the hot-plasma dispersion relation have previously shown that the minimum beam speed required to excite such instabilities is significantly smaller for oblique modes with $\\vec k \\times \\vec B_0\

  4. Ion cyclotron emission by spontaneous emission

    Energy Technology Data Exchange (ETDEWEB)

    Da Costa, O. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Gresillon, D. [Ecole Polytechnique, 91 - Palaiseau (France). Lab. de Physique des Milieux Ionises

    1994-07-01

    The goal of the study is to examine whether the spontaneous emission can account for ICE (ion cyclotron emission) experimental results, or part of them. A straightforward approach to plasma emission is chosen, investigating the near equilibrium wave radiation by gyrating ions, and thus building from the majority and fast fusion ions the plasma fluctuations and emission on the fast magnetoacoustic or compressional Alfven wave mode in the IC frequency range. Similarities with the ICE experiments are shown: the emission temperature in the presence of fast ions (even in a very small amount), the strong fast ion emission increase with the harmonic, the fine double-line splitting of each peak, the linear but not proportional increase of the peak width with the harmonic. 3 refs., 2 figs.

  5. Simulation of cyclotron resonant scattering features

    Directory of Open Access Journals (Sweden)

    Schwarm Fritz-Walter

    2014-01-01

    Full Text Available X-ray binary systems consisting of a mass donating optical star and a highly magnetized neutron star, under the right circumstances, show quantum mechanical absorption features in the observed spectra called cyclotron resonant scattering features (CRSFs. We have developed a simulation to model CRSFs using Monte Carlo methods. We calculate Green’s tables which can be used to imprint CRSFs to arbitrary X-ray continua. Our simulation keeps track of scattering parameters of individual photons, extends the number of variable parameters of previous works, and allows for more flexible geometries. Here we focus on the influence of bulk velocity of the accreted matter on the CRSF line shapes and positions.

  6. Ion cyclotron resonance heating system on Aditya

    Indian Academy of Sciences (India)

    D Bora; Sunil Kumar; Raj Singh; S V Kulkarni; A Mukherjee; J P Singh; Raguraj Singh; S Dani; A Patel; Sai Kumar; V George; Y S S Srinivas; P Khilar; M Kushwah; P Shah; H M Jadav; Rajnish Kumar; S Gangopadhyay; H Machhar; B Kadia; K Parmar; A Bhardwaj; Suresh Adav; D Rathi; D S Bhattacharya

    2005-02-01

    An ion cyclotron resonance heating (ICRH) system has been designed, fabricated indigenously and commissioned on Tokamak Aditya. The system has been commissioned to operate between 20·0 and 47·0 MHz at a maximum power of 200 kW continuous wave (CW). Duration of 500 ms is sufficient for operation on Aditya, however, the same system feeds the final stage of the 1·5 MW ICRH system being prepared for the steady-state superconducting tokamak (SST-1) for a duration of 1000 s. Radio frequency (RF) power (225 kW) has been generated and successfully tested on a dummy load for 100s at 30·0 MHz. Lower powers have been coupled to Aditya in a breakdown experiment. We describe the system in detail in this work.

  7. Electron cyclotron resonance heating and current drive

    Energy Technology Data Exchange (ETDEWEB)

    Fidone, I.; Castejon, F.

    1992-07-01

    A brief summary of the theory and experiments on electron- cyclotron heating and current drive is presented. The general relativistic formulation of wave propagation and linear absorption is considered in some detail. The O-mode and the X-mode for normal and oblique propagation are investigated and illustrated by several examples. The experimental verification of the theory in T-10 and D- III-D is briefly discussed. Quasilinear evolution of the momentum distribution and related applications as, for instance, non linear wave, damping and current drive, are also considered for special cases of wave frequencies, polarization and propagation. In the concluding section we present the general formulation of the wave damping and current drive in the absence of electron trapping for arbitrary values of the wave frequency. (Author) 13 refs.

  8. Improving cancer treatment with cyclotron produced radionuclides. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.; Finn, R.D.

    1993-11-01

    This report describes our continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section will be employed in the Pharmacology and Immunology sections during the next year. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  9. Semi-classical quantum theory for cyclotron radiation

    Institute of Scientific and Technical Information of China (English)

    陈军锋; 邓劲松; 徐毅; 尤峻汉

    1997-01-01

    A semi-classical quantum theory of the cyclotron radiation of the nonrelativistic thermal electrons in a very strong magnetic field is presented.The basic formulae of the absorption coefficient of cyclotron resonance kv and the absorption (scattering) cross-section of cyclotron resonance σv have been derived under the quadrupole approximation.σv is an important quantity in the study of the "magnetic inverse-Compton scattering".It is shown that σv is greatly larger than the Thomson cross-sectron σT,which is important in discussing the magnetic inverse-Compton scattering of the relativistic electrons in a very strong magnetic field.

  10. Accelerators for hadrontherapy: From Lawrence cyclotrons to linacs

    Science.gov (United States)

    Amaldi, U.; Bonomi, R.; Braccini, S.; Crescenti, M.; Degiovanni, A.; Garlasché, M.; Garonna, A.; Magrin, G.; Mellace, C.; Pearce, P.; Pittà, G.; Puggioni, P.; Rosso, E.; Verdú Andrés, S.; Wegner, R.; Weiss, M.; Zennaro, R.

    2010-08-01

    Hadrontherapy with protons and carbon ions is a fast developing methodology in radiation oncology. The accelerators used and planned for this purpose are reviewed starting from the cyclotrons used in the thirties. As discussed in the first part of this paper, normal and superconducting cyclotrons are still employed, together with synchrotrons, for proton therapy while for carbon ion therapy synchrotrons have been till now the only option. The latest developments concern a superconducting cyclotron for carbon ion therapy, fast-cycling high frequency linacs and 'single room' proton therapy facilities. These issues are discussed in the second part of the paper by underlining the present challenges, in particular the treatment of moving organs.

  11. Radiation Monitoring System of 30 MeV Cyclotron

    Science.gov (United States)

    Lee, Jin-Woo; Hur, Min-Goo; Jeong, Gyosung; Kim, Jongil

    2017-09-01

    A state-of-the-art radiation monitoring system was implemented at KAERI for a 30-MeV cyclotron. This system consists of several types of radiation measuring systems for ambient dose equivalent rate measurements of outside photon and neutron areas as well as inside the cyclotron, and monitors the alpha and beta particulates released from a stack, as well as the results of worker contamination at the portal of the cyclotron. In addition, an automatic alarm system is also mounted if there are alarms in the measuring systems.

  12. Global Simulation of Electromagnetic Ion Cyclotron Waves

    Science.gov (United States)

    Khazanov, George V.; Gallagher, D. L.; Kozyra, J. U.

    2007-01-01

    It is very well known that the effects of electromagnetic ion cyclotron (EMIC) waves on ring current (RC) ion and radiation belt (RB) electron dynamics strongly depend on such particle/wave characteristics as the phase-space distribution function, frequency, wave-normal angle, wave energy, and the form of wave spectral energy density. The consequence is that accurate modeling of EMIC waves and RC particles requires robust inclusion of the interdependent dynamics of wave growth/damping, wave propagation, and particles. Such a self-consistent model is being progressively developed by Khazanov et al. This model is based on a system of coupled kinetic equations for the RC and EMIC wave power spectral density along with the ray tracing equations. We will discuss the recent progress in understanding EMIC waves formation mechanisms in the inner magnetosphere. This problem remains unsettled in spite of many years of experimental and theoretical studies. Modern satellite observations by CRRES, Polar and Cluster still do not reveal the whole picture experimentally since they do not stay long enough in the generation region to give a full account of all the spatio-temporal structure of EMIC waves. The complete self-consistent theory taking into account all factors significant for EMIC waves generation remains to be developed. Several mechanisms are discussed with respect to formation of EMIC waves, among them are nonlinear modification of the ionospheric reflection by precipitating energetic protons, modulation of ion-cyclotron instability by long-period (Pc3/4) pulsations, reflection of waves from layers of heavy-ion gyroresonances, and nonlinearities of wave generation process. We show that each of these mechanisms have their attractive features and explains certain part experimental data but any of them, if taken alone, meets some difficulties when compared to observations. We conclude that development of a refined nonlinear theory and further correlated analysis of modern

  13. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy.

    Science.gov (United States)

    Cao, Yun; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia

    2014-02-01

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C(5+) ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C(5+) ion beam was got when work gas was CH4 while about 262 eμA of C(5+) ion beam was obtained when work gas was C2H2 gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  14. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy

    Science.gov (United States)

    Cao, Yun; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia

    2014-02-01

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C5+ ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C5+ ion beam was got when work gas was CH4 while about 262 eμA of C5+ ion beam was obtained when work gas was C2H2 gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  15. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Yun, E-mail: caoyun@impcas.ac.cn; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia [Institute of Modern Physics, CAS, Lanzhou 730000 (China)

    2014-02-15

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C{sup 5+} ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C{sup 5+} ion beam was got when work gas was CH{sub 4} while about 262 eμA of C{sup 5+} ion beam was obtained when work gas was C{sub 2}H{sub 2} gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  16. Recent development of RIKEN 28 GHz superconducting electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Higurashi, Y., E-mail: higurasi@riken.jp; Ohnishi, J.; Ozeki, K.; Kidera, M.; Nakagawa, T. [RIKEN, 2-1 Hirosawa, Wako, Saitama (Japan)

    2014-02-15

    Over the past two years, we have tried to improve the performance of the RIKEN superconducting electron cyclotron resonance ion source using several methods. For the production of U vapor, we chose the sputtering method because it is possible to install a large amount of material inside the plasma chamber and thus achieve long-term operation without a break, although it is assumed that the beam intensity is weaker than in the oven technique. We also used an aluminum chamber instead of a stainless steel one. Using these methods, we successfully produced ∼180 eμA of U{sup 35+} and ∼230 eμA of U{sup 33+} at the injected radio frequency (RF) power of ∼4 kW (28 GHz). Very recently, to further increase the beam intensity of U{sup 35+}, we have started to develop a high temperature oven and have successfully produced a highly charged U ion beam. In this contribution, we report on the beam intensity of highly charged U ions as a function of various parameters (RF power and sputtering voltage) and discuss the effects of these parameters on the beam stability in detail.

  17. Total on-line purchasing system (TOPS)

    Energy Technology Data Exchange (ETDEWEB)

    Collins, N.

    1995-11-01

    The Information Management Division (IMD) at LLNL is developing a new purchasing system for the Procurement Department. The first major development of this new system is called, {open_quotes}Total On-Line Purchasing System{close_quotes} (TOPS). TOPS will help speed up the requisitioning process by having requisitions electronically entered by requesters and electronically sent to buyers to be put on Purchase Orders. The new purchasing system will use Electronic Commerce (EC)/Electronic Data Interchange (EDI), to help increase transaction flows for shipping notices, RFQs, Quotes, Purchase Orders, and Invoices. ANSI X.12 is the EDI standard that this new EC will use.

  18. Recent radioactive ion beam program at RIKEN and related topics

    Indian Academy of Sciences (India)

    Akira Ozawa

    2001-08-01

    Recent experimental programs at RIKEN concerning RI beams are reviewed. RIKEN has the ring cyclotron (RRC) with high intense heavy-ion beams and large acceptance fragment separator, RIPS. The complex can provide high intense RI-beams. By using the high intense RI-beams, a variety of experiments have been done. Recently, nuclear structure for unstable nuclei has been paid much attention. In special, disappearance and appearance of magic numbers are discussed experimentally and theoretically. Thus, in this review, related experiments concerning disappearance and appearance of magic numbers are described. Finally, future project in RIKEN, RI-beam factory, is introduced briefly.

  19. Production of an accelerated oxygen-14 beam

    CERN Document Server

    Powell, J; Cerny, J

    2003-01-01

    BEARS is an ongoing project to provide a light-ion radioactive-beam capability at the 88-Inch Cyclotron at LBNL. Light radioactive isotopes are produced at a 10 MeV proton medical cyclotron, transported 350 m via a high-speed gas transport capillary, cryogenically separated, and injected into the 88-Inch Cyclotron's ion source. The first radioactive beam successfully accelerated was carbon-11 and beams of intensity more than 10 sup 8 ions/s have been utilized for experiments. Development of oxygen-14 as the second BEARS beam presented considerable technical challenges, both due to its short half-life of 71 s and the radiation chemistry of oxygen in the target. The usual techniques developed for medical uses of oxygen-15 involve the addition of significant amounts of carrier oxygen, something that would overload the ion source. As a solution, oxygen-14 is produced as water in a carrier-free form, and is chemically converted in two steps to carbon dioxide, a form readily usable by the BEARS. This system has bee...

  20. Development of a PET cyclotron based irradiation setup for proton radiobiology

    Science.gov (United States)

    Ghithan, Sharif; Crespo, Paulo; do Carmo, S. J. C.; Ferreira Marques, Rui; Fraga, F. A. F.; Simões, Hugo; Alves, Francisco; Rachinhas, P. J. B. M.

    2015-02-01

    An out-of-yoke irradiation setup using the proton beam from a cyclotron that ordinary produces radioisotopes for positron emission tomography (PET) has been developed, characterized, calibrated and validated. The current from a 20 μm thick aluminum transmission foil is readout by home-made transimpedance electronics, providing online dose information. The main monitoring variables, delivered in real-time, include beam current, integrated charge and dose rate. Hence the dose and integrated current delivered at a given instant to an experimental setup can be computer-controlled with a shutter. In this work, we report on experimental results and Geant4 simulations of a setup which exploits for the first time the 18 MeV proton beam from a PET cyclotron to irradiate a selected region of a target using the developed irradiation system. By using this system, we are able to deliver a homogeneous beam on targets with 18 mm diameter, allowing to achieve the controlled irradiation of cell cultures located in biological multi-well dishes of 16 mm diameter. We found that the magnetic field applied inside the cyclotron plays a major role for achieving the referred to homogeneity. The quasi-Gaussian curve obtained by scanning the magnet current and measuring the corresponding dose rate must be measured before any irradiation procedure, with the shutter closed. At the optimum magnet current, which corresponds to the center of the Gaussian, a homogenous dose is observed over the whole target area. Making use of a rotating disk with a slit of 0.5 mm at a radius of 150 mm, we could measure dose rates on target ranging from 500 mGy/s down to 5 mGy/s. For validating the developed irradiation setup, several Gafchromic® EBT2 films were exposed to different values of dose. The absolute dose in the irradiated films were assessed in the 2D film dosimetry system of the Department of Radiotherapy of Coimbra University Hospital Center with a precision better than 2%. In the future, we plan

  1. Characteristics comparison between a cyclotron-based neutron source and KUR-HWNIF for boron neutron capture therapy

    Science.gov (United States)

    Tanaka, H.; Sakurai, Y.; Suzuki, M.; Masunaga, S.; Kinashi, Y.; Kashino, G.; Liu, Y.; Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Maruhashi, A.; Ono, K.

    2009-06-01

    At Kyoto University Research Reactor Institute (KURRI), 275 clinical trials of boron neutron capture therapy (BNCT) have been performed as of March 2006, and the effectiveness of BNCT has been revealed. In order to further develop BNCT, it is desirable to supply accelerator-based epithermal-neutron sources that can be installed near the hospital. We proposed the method of filtering and moderating fast neutrons, which are emitted from the reaction between a beryllium target and 30-MeV protons accelerated by a cyclotron accelerator, using an optimum moderator system composed of iron, lead, aluminum and calcium fluoride. At present, an epithermal-neutron source is under construction from June 2008. This system consists of a cyclotron accelerator, beam transport system, neutron-yielding target, filter, moderator and irradiation bed. In this article, an overview of this system and the properties of the treatment neutron beam optimized by the MCNPX Monte Carlo neutron transport code are presented. The distribution of biological effect weighted dose in a head phantom compared with that of Kyoto University Research Reactor (KUR) is shown. It is confirmed that for the accelerator, the biological effect weighted dose for a deeply situated tumor in the phantom is 18% larger than that for KUR, when the limit dose of the normal brain is 10 Gy-eq. The therapeutic time of the cyclotron-based neutron sources are nearly one-quarter of that of KUR. The cyclotron-based epithermal-neutron source is a promising alternative to reactor-based neutron sources for treatments by BNCT.

  2. On-line and Mobil Learning Activities

    Science.gov (United States)

    Ackerman, S. A.; Whittaker, T. M.; Jasmin, T.; Mooney, M. E.

    2012-12-01

    Introductory college-level science courses for non-majors are critical gateways to imparting not only discipline-specific information, but also the basics of the scientific method and how science influences society. They are also indispensable for student success to degree. On-line, web-based homework (whether on computers or mobile devices) is a rapidly growing use of the Internet and is becoming a major component of instruction in science, replacing delayed feedback from a few major exams. Web delivery and grading of traditional textbook-type questions is equally effective as having students write them out for hand grading, as measured by student performance on conceptual and problem solving exams. During this presentation we will demonstrate some of the interactive on-line activities used to teach concepts and how scientists approach problem solving, and how these activities have impacted student learning. Evaluation of the activities, including formative and summative, will be discussed and provide evidence that these interactive activities significantly enhance understanding of introductory meteorological concepts in a college-level science course. More advanced interactive activities are also used in our courses for department majors, some of these will be discussed and demonstrated. Bring your mobile devices to play along! Here is an example on teaching contouring: http://profhorn.aos.wisc.edu/wxwise/contour/index.html

  3. Fast particle-driven ion cyclotron emission (ICE) in tokamak plasmas and the case for an ICE diagnostic in ITER

    CERN Document Server

    McClements, K G; Dendy, R O; Carbajal, L; Chapman, S C; Cook, J W S; Harvey, R W; Heidbrink, W W; Pinches, S D

    2014-01-01

    Fast particle-driven waves in the ion cyclotron frequency range (ion cyclotron emission or ICE) have provided a valuable diagnostic of confined and escaping fast ions in many tokamaks. This is a passive, non-invasive diagnostic that would be compatible with the high radiation environment of deuterium-tritium plasmas in ITER, and could provide important information on fusion {\\alpha}-particles and beam ions in that device. In JET, ICE from confined fusion products scaled linearly with fusion reaction rate over six orders of magnitude and provided evidence that {\\alpha}-particle confinement was close to classical. In TFTR, ICE was observed from super-Alfv\\'enic {\\alpha}-particles in the plasma edge. The intensity of beam-driven ICE in DIII-D is more strongly correlated with drops in neutron rate during fishbone excitation than signals from more direct beam ion loss diagnostics. In ASDEX Upgrade ICE is produced by both super-Alfv\\'enic DD fusion products and sub-Alfv\\'enic deuterium beam ions.

  4. Plasma-Sheath Instability in Hall Thrusters Due to Periodic Modulation of the Energy of Secondary Electrons in Cyclotron Motion

    Energy Technology Data Exchange (ETDEWEB)

    Sydorenko, D.; Smolyakov, A.; Kaganovich, I.; Raitses, Y.

    2008-04-23

    Particle-in-cell simulation of Hall thruster plasmas reveals a plasma-sheath instability manifesting itself as a rearrangement of the plasma sheath near the thruster channel walls accompanied by a sudden change of many discharge parameters. The instability develops when the sheath current as a function of the sheath voltage is in the negative conductivity regime. The major part of the sheath current is produced by beams of secondary electrons counter-streaming between the walls. The negative conductivity is the result of nonlinear dependence of beam-induced secondary electron emission on the plasma potential. The intensity of such emission is defined by the beam energy. The energy of the beam in crossed axial electric and radial magnetic fields is a quasi-periodical function of the phase of cyclotron rotation, which depends on the radial profile of the potential and the thruster channel width. There is a discrete set of stability intervals determined by the final phase of the cyclotron rotation of secondary electrons. As a result, a small variation of the thruster channel width may result in abrupt changes of plasma parameters if the plasma state jumps from one stability interval to another.

  5. Versatile Ion-polarized Techniques On-line (VITO) experiment at ISOLDE-CERN

    Energy Technology Data Exchange (ETDEWEB)

    Stachura, M., E-mail: monika.stachura@cern.ch [CERN, 1211 Geneva 23 (Switzerland); Gottberg, A. [CERN, 1211 Geneva 23 (Switzerland); Johnston, K. [CERN, 1211 Geneva 23 (Switzerland); Universität des Saarlandes, Experimentalphysik, 66123 Saabrucken (Germany); Bissell, M.L.; Garcia Ruiz, R.F. [Instituut voor Kern- en Stralingsfysica, KU Leuven, Celestijnenlaan 200 D, 3001 Leuven (Belgium); Martins Correia, J.; Granadeiro Costa, A.R. [Centro de Ciências e Tecnologias Nucleares - C" 2TN, Instituto Superior Técnico, Campus Tecnológico e Nuclear, Estrada Nacional 10 (km 139,7), 2695-066 Bobadela LRS (Portugal); Dehn, M. [Technische Universität München, Physics Department, James-Franck-Str. 1, 85748 Garching (Germany); Deicher, M. [Universität des Saarlandes, Experimentalphysik, 66123 Saabrucken (Germany); Fenta, A. [CICECO, Complexo de Laboratórios Tecnológicos, Campus Universitário de Santiago, 3810-193 Aveiro (Portugal); Hemmingsen, L. [Kemisk Institut, Københavns Universitet, Universtetsparken 5, 2100 København (Denmark); Mølholt, T.E. [CERN, 1211 Geneva 23 (Switzerland); Munch, M. [Institut for Fysik og Astronomi, Aarhus Universitet, Ny Munkegade 120, 8000 Aarhus C (Denmark); Neyens, G. [Instituut voor Kern- en Stralingsfysica, KU Leuven, Celestijnenlaan 200 D, 3001 Leuven (Belgium); and others

    2016-06-01

    The VITO (Versatile Ion-polarized Techniques Online) project is a new experimental setup at the ISOLDE facility at CERN. VITO is a dedicated beam line for producing laser-induced spin-polarized beams of both, atoms and ions, and it has been commissioned in response to the continuously growing demand for the use of spin-polarized beams. The new VITO beam line is a modification of the formerly existing ultra-high vacuum beam line, connecting ASPIC (Apparatus for Surface Physics and Interfaces at CERN), and it has been under construction since the beginning of 2014. Once fully commissioned, VITO will open up numerous possibilities for carrying out multidisciplinary experiments in the areas of nuclear and solid state physics, fundamental interaction physics and biophysics. In its final stage the VITO beam line will provide three fully independent experimental stations: UHV chamber for material science applications, a β-asymmetry station where highly-polarized ions will be available, and a central open-end station suitable for travelling experiments. The VITO beam line will operate in two different modes providing either beams of spin-polarized atoms or ions, or non-polarized ion beams to all three end stations operating from 10{sup −10} mbar to 50 mbar. Recent experimental campaigns with stable and radioactive beams have allowed for testing VITO’s constituent parts and have demonstrated 96% of ion beam transmission to the collection chamber installed on the central station. The first experimental results obtained with on-line Perturbed Angular Correlation (PAC) spectroscopy using {sup 68m}Cu ion-beams will be briefly discussed.

  6. Versatile Ion-polarized Techniques On-line (VITO) experiment at ISOLDE-CERN

    Science.gov (United States)

    Stachura, M.; Gottberg, A.; Johnston, K.; Bissell, M. L.; Garcia Ruiz, R. F.; Martins Correia, J.; Granadeiro Costa, A. R.; Dehn, M.; Deicher, M.; Fenta, A.; Hemmingsen, L.; Mølholt, T. E.; Munch, M.; Neyens, G.; Pallada, S.; Silva, M. R.; Zakoucky, D.

    2016-06-01

    The VITO (Versatile Ion-polarized Techniques Online) project is a new experimental setup at the ISOLDE facility at CERN. VITO is a dedicated beam line for producing laser-induced spin-polarized beams of both, atoms and ions, and it has been commissioned in response to the continuously growing demand for the use of spin-polarized beams. The new VITO beam line is a modification of the formerly existing ultra-high vacuum beam line, connecting ASPIC (Apparatus for Surface Physics and Interfaces at CERN), and it has been under construction since the beginning of 2014. Once fully commissioned, VITO will open up numerous possibilities for carrying out multidisciplinary experiments in the areas of nuclear and solid state physics, fundamental interaction physics and biophysics. In its final stage the VITO beam line will provide three fully independent experimental stations: UHV chamber for material science applications, a β-asymmetry station where highly-polarized ions will be available, and a central open-end station suitable for travelling experiments. The VITO beam line will operate in two different modes providing either beams of spin-polarized atoms or ions, or non-polarized ion beams to all three end stations operating from 10-10 mbar to 50 mbar. Recent experimental campaigns with stable and radioactive beams have allowed for testing VITO's constituent parts and have demonstrated 96% of ion beam transmission to the collection chamber installed on the central station. The first experimental results obtained with on-line Perturbed Angular Correlation (PAC) spectroscopy using 68mCu ion-beams will be briefly discussed.

  7. Impedance matching network systems using stub-lines of 20 kW CW RF amplifier for SKKUCY-9 compact cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hyun; Song, Ho Seung; Kim, Jeong Hwan; Cong, Truong Van; Kim, Hui Su; Yeon, Yeong Heum; Lee, Yong seok; Chai, Jong Seo, E-mail: jschai@skku.edu

    2015-01-21

    The SKKUCY-9 is a compact cyclotron for radioactive isotopes (RI) production of positron emission tomography (PET). Charged particles such as H-ions are accelerated azimuthally within a high intensity electric field (E-field) generated from a radio frequency (RF) system in cyclotron. A high power RF signal is transmitted from an RF amplifier to an RF resonating cavity. The RF system of the SKKUCY-9 operates in continuous wave (CW) mode. If an ion beam were accelerated in the cyclotron, the vacuum level and permittivity would be changed because of beam loading. It causes an impedance shift of the RF resonating cavity. This impedance mismatch generates reflected power that decreases the RF transmitting power. To prevent this situation, an impedance matching system is necessary. This paper describes the impedance matching system of a 20 kW RF amplifier in an SKKUCY-9 compact cyclotron. The impedance matching circuit was designed using both an input stage and output stage, which are divided between the cathode and anode in a vacuum tube that is used as an amplifying device. The equivalent circuit of the matching system is made of passive elements. The characteristic results of designed circuit were calculated using a Smith chart. In assembling, the inductors were replaced by movable stub-line structures. The dimensions of the stub-line structures were optimized with equations and the measurement results. The experiment was performed to find the result values of matching circuit impedance and RF power amplitude.

  8. An after-market, five-port vertical beam line extension for the PETtrace

    DEFF Research Database (Denmark)

    Barnhart, T. E.; Engle, J. W.; Severin, Gregory

    2012-01-01

    Most commercial cyclotrons intended for medical isotope production provide a limited number of beam ports crowded into a minimal vault space. Taking advantage of our new lab construction, we planned and installed a beam-line on port ♯2 of our GEMS PETtrace to bring beam to an additional 5 target...... positions. These are oriented in the vertical plane, with the downward directed beam well suited for molten target substrates. © 2012 American Institute of Physics...

  9. An after-market, five-port vertical beam line extension for the PETtrace

    Science.gov (United States)

    Barnhart, T. E.; Engle, J. W.; Severin, G. W.; Valdovinos, H. F.; Gagnon, K.; Nickles, R. J.

    2012-12-01

    Most commercial cyclotrons intended for medical isotope production provide a limited number of beam ports crowded into a minimal vault space. Taking advantage of our new lab construction, we planned and installed a beam-line on port ♯2 of our GEMS PETtrace to bring beam to an additional 5 target positions. These are oriented in the vertical plane, with the downward directed beam well suited for molten target substrates.

  10. Cyclotron mode frequency shifts in multi-species ion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Affolter, M.; Anderegg, F.; Dubin, D.H.E.; Driscoll, C.F.

    2014-06-27

    In trapped plasmas, electric fields and collective effects shift the cyclotron mode frequencies away from the “bare” cyclotron frequency for each species s. Here, these shifts are measured on a set of cyclotron modes (m=0,1, and 2) with cos(mθ) azimuthal dependence in near rigid-rotor multi-species ion plasmas. We observe that these frequency shifts are dependent on the plasma density, through the E×B rotation frequency f{sub E}, and on the “local” charge concentration δ{sub s} of species s, in close agreement with theory. - Highlights: • Cyclotron modes varying as sin(mθ) with m=0,1and2 are detected. • These mode frequencies shift by factors of the ExB rotation frequency. • These frequency shifts depend on the species charge fraction and radial distribution. • Centrifugal separation of species can greatly modify these frequency shifts.

  11. Cryogenic system for VECC K500 superconducting cyclotron

    CERN Document Server

    Pal, G; Bhattacharyya, T K; Bhandari, R K

    2009-01-01

    VEC Centre, Kolkata in India is at an advanced stage of commissioning a K500 superconducting cyclotron. The superconducting coil of the magnet for cyclotron is cooled by liquid helium. Three liquid helium cooled cryopanels, placed inside the Dees of the radiofrequency system, maintain the vacuum in the acceleration region of the superconducting cyclotron. The cryogenic system for magnet for cyclotron has been tested by cooling the coil and energizing the magnet. The cryogenic system for cryopanels has also been tested. Heater and temperature sensor were placed on the liquid helium cold head for cryopanel. The temperature of the cold head was observed to be below 20 K upto a heat load of 11.7 watt.

  12. Single electron detection and spectroscopy via relativistic cyclotron radiation

    CERN Document Server

    Asner, D M; de Viveiros, L; Doe, P J; Fernandes, J L; Fertl, M; Finn, E C; Formaggio, J A; Furse, D; Jones, A M; Kofron, J N; LaRoque, B H; Leber, M; McBride, E L; Miller, M L; Mohanmurthy, P; Monreal, B; Oblath, N S; Robertson, R G H; Rosenberg, L J; Rybka, G; Rysewyk, D; Sternberg, M G; Tedeschi, J R; Thummler, T; VanDevender, B A; Woods, N L

    2014-01-01

    It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spec- trometer. We observe the cyclotron radiation emitted by individual magnetically-trapped electrons that are produced with mildly-relativistic energies by a gaseous radioactive source. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta elec- tron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work demonstrates a fundamentally new approach to precision beta sp...

  13. Single-electron detection and spectroscopy via relativistic cyclotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Asner, David M.; Bradley, Rich; De Viveiros Souza Filho, Luiz A.; Doe, Peter J.; Fernandes, Justin L.; Fertl, M.; Finn, Erin C.; Formaggio, Joseph; Furse, Daniel L.; Jones, Anthony M.; Kofron, Jared N.; LaRoque, Benjamin; Leber, Michelle; MCBride, Lisa; Miller, M. L.; Mohanmurthy, Prajwal T.; Monreal, Ben; Oblath, Noah S.; Robertson, R. G. H.; Rosenberg, Leslie; Rybka, Gray; Rysewyk, Devyn M.; Sternberg, Michael G.; Tedeschi, Jonathan R.; Thummler, Thomas; VanDevender, Brent A.; Woods, N. L.

    2015-04-01

    It has been understood since 1897 that accelerating charges should emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spectrometer. We observe the cyclotron radiation emitted by individual electrons that are produced with mildly-relativistic energies by a gaseous radioactive source and are magnetically trapped. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work is a proof-of-concept for future neutrino mass experiments using this technique.

  14. The fundamental cyclotron line in 4U 1538-52

    CERN Document Server

    Rodes-Roca, J J; Bernabéu, J G

    2009-01-01

    We present pulse phase averaged spectra of the high mass X-ray binary pulsar 4U 1538-52/QV Nor. Observations of this persistent accreting pulsar were made with the Rossi X-ray Timing Explorer (RXTE). We study the variability of cyclotron resonant scattering feature (CRSF or simply cyclotron line) in the high energy spectra of this binary system. We show that the parameters of the CRSF are correlated. The first one is, as suggested by theory, between the width and the energy of the cyclotron line. The second one is between the relative width and the optical depth of the cyclotron line. We discuss these results with studies of other X-ray pulsars and their implications on the line variability.

  15. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 32

    Energy Technology Data Exchange (ETDEWEB)

    1968-06-28

    Completion of magnet tests, followed by completion of installation of major cyclotron components, are reported. Intermediate level power tests of the rf system are also reported. Design and fabrication of the control system are reported to be under way. (LEW)

  16. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 26

    Energy Technology Data Exchange (ETDEWEB)

    1968-01-17

    Progress is reported in the fabrication, installation, and testing of cyclotron components, including magnets and coils, rf components, vacuum and control equipment. Also reported are magnet and rf component measurements. (LEW)

  17. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 23

    Energy Technology Data Exchange (ETDEWEB)

    1967-10-09

    Progress is reported in the design, installation of various components of the cyclotron, including coils, magnets, rf system, and vacuum system. Also reported are measurements on magnets and rf components. (LEW)

  18. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 20

    Energy Technology Data Exchange (ETDEWEB)

    1967-06-30

    Progress is reported in the fabrication and testing of cyclotron components, including magnet system and rf system components. Work on vacuum components and instrumentation and control equipment is also reported. (LEW)

  19. Fusion Reactivity in the Case of Ion Cyclotron Resonant Heating

    Institute of Scientific and Technical Information of China (English)

    俞国扬; 常永斌; 沈林芳

    2003-01-01

    By applying the integral-variable-change technique,an explicit expression of deuterium-tritium fusion reactivity in the case of second harmonic ion cyclotron resonant heating on deuterium is obtained.

  20. Beam Phase Detection for Proton Therapy Accelerators

    CERN Document Server

    Aminov, Bachtior; Getta, Markus; Kolesov, Sergej; Pupeter, Nico; Stephani, Thomas; Timmer, J

    2005-01-01

    The industrial application of proton cyclotrons for medical applications has become one of the important contributions of accelerator physics during the last years. This paper describes an advanced vector demodulating technique used for non-destructive measurements of beam intensity and beam phase over 360°. A computer controlled I/Q-based phase detector with a very large dynamic range of 70 dB permits the monitoring of beam intensity, phase and eventually energy for wide range of beam currents down to -130 dBm. In order to avoid interference from the fundamental cyclotron frequency the phase detection is performed at the second harmonic frequency. A digital low pass filter with adjustable bandwidth and steepness is implemented to improve accuracy. With a sensitivity of the capacitive pickup in the beam line of 30 nV per nA of proton beam current at 250 MeV, accurate phase and intensity measurements can be performed with beam currents down to 3.3 nA.

  1. Beam interactions with surface waves and higher-order modes in oversized backward wave oscillators

    Energy Technology Data Exchange (ETDEWEB)

    Ogura, Kazuo; Kojima, Akihiko; Kawabe, Fumiaki; Yambe, Kiyoyuki [Niigata University, Niigata (Japan); Amin, Ruhul [Islamic University of Technology, Gazipur (Bangladesh)

    2014-10-15

    Beam interactions with surface waves and higher-order modes in an oversized backward wave oscillator (BWO) are studied. In addition to the well-known Cherenkov interaction, the slow cyclotron interaction occurs due to transverse perturbations of the electron beam. The Cherenkov interaction dominates the slow cyclotron interaction. Growth rates of both the interactions for the higher order modes are small compared with those for the surface-wave modes in an oversized BWO. The coaxial slow-wave structure exhibits a reduced number of higher-order modes, which consequently reduces the mode competition problem and improves beam interactions with higher order modes. For higher values of beam currents, the slow cyclotron wave grows at a faster rate than the Cherenkov waves.

  2. Effective dose to immuno-PET patients due to metastable impurities in cyclotron produced zirconium-89

    Science.gov (United States)

    Alfuraih, Abdulrahman; Alzimami, Khalid; Ma, Andy K.; Alghamdi, Ali; Al Jammaz, Ibrahim

    2014-11-01

    Immuno-PET is a nuclear medicine technique that combines positron emission tommography (PET) with radio-labeled monoclonal antibodies (mAbs) for tumor characterization and therapy. Zirconium-89 (89Zr) is an emerging radionuclide for immuno-PET imaging. Its long half-life (78.4 h) gives ample time for the production, the administering and the patient uptake of the tagged radiopharmaceutical. Furthermore, the nuclides will remain in the tumor cells after the mAbs are catabolized so that time series studies are possible without incurring further administration of radiopharmarceuticals. 89Zr can be produced in medical cyclotrons by bombarding an yttrium-89 (89Y) target with a proton beam through the 89Y(p,n)89Zr reaction. In this study, we estimated the effective dose to the head and neck cancer patients undergoing 89Zr-based immune-PET procedures. The production of 89Zr and the impurities from proton irradiation of the 89Y target in a cyclotron was calculated with the Monte Carlo code MCNPX and the nuclear reaction code TALYS. The cumulated activities of the Zr isotopes were derived from real patient data in literature and the effective doses were estimated using the MIRD specific absorbed fraction formalism. The estimated effective dose from 89Zr is 0.5±0.2 mSv/MBq. The highest organ dose is 1.8±0.2 mSv/MBq in the liver. These values are in agreement with those reported in literature. The effective dose from 89mZr is about 0.2-0.3% of the 89Zr dose in the worst case. Since the ratio of 89mZr to 89Zr depends on the cooling time as well as the irradiation details, contaminant dose estimation is an important aspect in optimizing the cyclotron irradiation geometry, energy and time.

  3. Nuclear Structure and Nuclear Astrophysics Studies with Fast Heavy-Ion Beams

    Science.gov (United States)

    Motobayashi, Tohru

    Collaboration between France and Japan on studies with fast RI (radioactive isotope) beams and related technical developments started in 1980s, when the GANIL accelerators and RIKEN cyclotron complex started operation and RI beam production technique was developed. Several examples of collaboration on nuclear physics and nuclear astrophysics experiments including related technical development are discussed.

  4. Aprender a innovar: una experiencia on line

    Directory of Open Access Journals (Sweden)

    Joaquín MORENO MARCHAL

    2014-11-01

    Full Text Available La creatividad y la innovación se han convertido en recursos clave en la denominada sociedad del conocimiento, que bien podría ser también llamada sociedad de la innovación. Pero innovar es una actividad compleja, que integra la aplicación de múltiples capacidades, el pensamiento divergente y convergente, la gestión de equipos humanos, la comunicación. Ahora bien, a innovar se puede, y se debe, aprender. Aprender a innovar es un reto y también una obligación para el conjunto del sistema educativo en todos sus niveles. Partiendo de estas consideraciones este trabajo expone una experiencia de aprendizaje de la creatividad y de la innovación a través de un curso totalmente on line basado en la plataforma MOODLE, en el marco del Programa de Formación Permanente de la Universidad de Cádiz. Se presenta un modelo del proceso de innovación, denominado CREALAB, de elaboración propia. Este modelo se ha utilizado como base del proceso de aprendizaje de la creatividad y de la innovación y en el diseño del curso, está organizado en torno a actividades y tiene un carácter iterativo y realimentado. Se presentan además el conjunto del diseño metodológico y los resultados obtenidos en las dos ediciones celebradas hasta el momento. El diseño del curso totalmente on line y los resultados alcanzados permiten estimar un alto potencial de aplicación, tanto a nivel personal como a nivel organizacional.

  5. On-line chemical composition analyzer development

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, M.J.; Garrison, A.A.; Muly, E.C.; Moore, C.F.

    1992-02-01

    The energy consumed in distillation processes in the United States represents nearly three percent of the total national energy consumption. If effective control of distillation columns can be accomplished, it has been estimated that it would result in a reduction in the national energy consumption of 0.3%. Real-time control based on mixture composition could achieve these savings. However, the major distillation processes represent diverse applications and at present there does not exist a proven on-line chemical composition sensor technology which can be used to control these diverse processes in real-time. This report presents a summary of the findings of the second phase of a three phase effort undertaken to develop an on-line real-time measurement and control system utilizing Raman spectroscopy. A prototype instrument system has been constructed utilizing a Perkin Elmer 1700 Spectrometer, a diode pumped YAG laser, two three axis positioning systems, a process sample cell land a personal computer. This system has been successfully tested using industrially supplied process samples to establish its performance. Also, continued application development was undertaken during this Phase of the program using both the spontaneous Raman and Surface-enhanced Raman modes of operation. The study was performed for the US Department of Energy, Office of Industrial Technologies, whose mission is to conduct cost-shared R D for new high-risk, high-payoff industrial energy conservation technologies. Although this document contains references to individual manufacturers and their products, the opinions expressed on the products reported do not necessarily reflect the position of the Department of Energy.

  6. On-Line Texture Diagnostics for Coated Conductor Manufacture. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    White, M. K.

    2002-12-30

    This Phase I project was undertaken to assess the feasibility of implementing a particular diagnostic method for characterizing the crystallographic texture of high temperature superconductor (HTS) coated conductors on-line during their reel-to-reel continuous manufacture. Key factors in this technique were the use of an area detector to greatly reduce scan time, an x-ray mirror to enhance incident beam brightness, and an automation scheme for diffractometer control, tape motion control, and calculation and output of texture characterizations.

  7. First results of 28 GHz superconducting electron cyclotron resonance ion source for KBSI accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Yong; Lee, Byoung-Seob; Choi, Seyong; Kim, Seong Jun; Ok, Jung-Woo; Yoon, Jang-Hee; Kim, Hyun Gyu; Shin, Chang Seouk; Hong, Jonggi; Bahng, Jungbae; Won, Mi-Sook, E-mail: mswon@kbsi.re.kr [Busan Center, Korea Basic Science Institute, Busan 609-735 (Korea, Republic of)

    2016-02-15

    The 28 GHz superconducting electron cyclotron resonance (ECR) ion source has been developed to produce a high current heavy ion for the linear accelerator at KBSI (Korea Basic Science Institute). The objective of this study is to generate fast neutrons with a proton target via a p(Li,n)Be reaction. The design and fabrication of the essential components of the ECR ion source, which include a superconducting magnet with a liquid helium re-condensed cryostat and a 10 kW high-power microwave, were completed. The waveguide components were connected with a plasma chamber including a gas supply system. The plasma chamber was inserted into the warm bore of the superconducting magnet. A high voltage system was also installed for the ion beam extraction. After the installation of the ECR ion source, we reported the results for ECR plasma ignition at ECRIS 2014 in Russia. Following plasma ignition, we successfully extracted multi-charged ions and obtained the first results in terms of ion beam spectra from various species. This was verified by a beam diagnostic system for a low energy beam transport system. In this article, we present the first results and report on the current status of the KBSI accelerator project.

  8. First results of 28 GHz superconducting electron cyclotron resonance ion source for KBSI accelerator

    Science.gov (United States)

    Park, Jin Yong; Lee, Byoung-Seob; Choi, Seyong; Kim, Seong Jun; Ok, Jung-Woo; Yoon, Jang-Hee; Kim, Hyun Gyu; Shin, Chang Seouk; Hong, Jonggi; Bahng, Jungbae; Won, Mi-Sook

    2016-02-01

    The 28 GHz superconducting electron cyclotron resonance (ECR) ion source has been developed to produce a high current heavy ion for the linear accelerator at KBSI (Korea Basic Science Institute). The objective of this study is to generate fast neutrons with a proton target via a p(Li,n)Be reaction. The design and fabrication of the essential components of the ECR ion source, which include a superconducting magnet with a liquid helium re-condensed cryostat and a 10 kW high-power microwave, were completed. The waveguide components were connected with a plasma chamber including a gas supply system. The plasma chamber was inserted into the warm bore of the superconducting magnet. A high voltage system was also installed for the ion beam extraction. After the installation of the ECR ion source, we reported the results for ECR plasma ignition at ECRIS 2014 in Russia. Following plasma ignition, we successfully extracted multi-charged ions and obtained the first results in terms of ion beam spectra from various species. This was verified by a beam diagnostic system for a low energy beam transport system. In this article, we present the first results and report on the current status of the KBSI accelerator project.

  9. The electron cyclotron resonance ion source with arc-shaped coils concept (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Koivisto, H.; Tarvainen, O. [Department of Physics, University of Jyvaeskylae, Jyvaeskylae (Finland); Suominen, P. [CERN, CH-1211 Geneve 23 (Switzerland); Spaedtke, P. [GSI, Darmstadt, Planckstr. 1, 64221 Darmstadt (Germany)

    2012-02-15

    The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cost-driven compromises such as extraction mirror ratio of 1.05-1.2, microwave frequency of 6.4 GHz, and beam line with limited capacity, Ar{sup 4+} beam intensity of up to 2 {mu}A was measured. Subsequent design study has shown that the ARC-ECRIS operating at the microwave frequency above 40 GHz could be constructed. This specific design would be based on NbTi-wires and it fulfills the experimental magnetic field scaling laws. In this article, the ARC-ECRIS concept and its potential applications will be described.

  10. Electron beam injection during active experiments. I - Electromagnetic wave emissions

    Science.gov (United States)

    Winglee, R. M.; Kellogg, P. J.

    1990-01-01

    The wave emissions produced in Echo 7 experiment by active injections of electron beams were investigated to determine the properties of the electromagnetic and electrostatic fields for both the field-aligned and cross-field injection in such experiments and to evaluate the sources of free energy and relative efficiencies for the generation of the VLF and HF emissions. It is shown that, for typical beam energies in active experiments, electromagnetic effects do not substantially change the bulk properties of the beam, spacecraft charging, and plasma particle acceleration. Through simulations, beam-generated whistlers; fundamental z-mode and harmonic x-mode radiation; and electrostatic electron-cyclotron, upper-hybrid, Langmuir, and lower-hybrid waves were identified. The characteristics of the observed wave spectra were found to be sensitive to both the ratio of the electron plasma frequency to the cyclotron frequency and the angle of injection relative to the magnetic field.

  11. Electron cyclotron emission diagnostic for ITER.

    Science.gov (United States)

    Rowan, W; Austin, M; Beno, J; Ellis, R; Feder, R; Ouroua, A; Patel, A; Phillips, P

    2010-10-01

    Electron temperature measurements and electron thermal transport inferences will be critical to the nonactive and deuterium phases of ITER operation and will take on added importance during the alpha heating phase. The diagnostic must meet stringent criteria on spatial coverage and spatial resolution during full field operation. During the early phases of operation, it must operate equally well at half field. The key to the diagnostic is the front end design. It consists of a quasioptical antenna and a pair of calibration sources. The radial resolution of the diagnostic is less than 0.06 m. The spatial coverage extends at least from the core to the separatrix with first harmonic O-mode being used for the core and second harmonic X-mode being used for the pedestal. The instrumentation used for the core measurement at full field can be used for detection at half field by changing the detected polarization. Intermediate fields are accessible. The electron cyclotron emission systems require in situ calibration, which is provided by a novel hot calibration source. The critical component for the hot calibration source, the emissive surface, has been successfully tested. A prototype hot calibration source has been designed, making use of extensive thermal and mechanical modeling.

  12. Cyclotron-based effects on plant gravitropism

    Science.gov (United States)

    Kordyum, E.; Sobol, M.; Kalinina, Ia.; Bogatina, N.; Kondrachuk, A.

    Primary roots exhibit positive gravitropism and grow in the direction of the gravitational vector, while shoots respond negatively and grow opposite to the gravitational vector. We first demonstrated that the use of a weak combined magnetic field (CMF), which is comprised of a permanent magnetic field and an alternating magnetic field with the frequency resonance of the cyclotron frequency of calcium ions, can change root gravitropism from a positive direction to negative direction. Two-day-old cress seedlings were gravistimulated in a chamber that was placed into a μ-metal shield where this CMF was created. Using this "new model" of a root gravitropic response, we have studied some of its components including the movement of amyloplasts-statoliths in root cap statocytes and the distribution of Ca 2+ ions in the distal elongation zone during gravistimulation. Unlike results from the control, amyloplasts did not sediment in the distal part of a statocyte, and more Ca 2+ accumulation was observed in the upper side of a gravistimulated root for seedlings treated with the CMF. For plants treated with the CMF, it appears that a root gravitropic reaction occurs by a normal physiological process resulting in root bending although in the opposite direction. These results support the hypothesis that both the amyloplasts in the root cap statocytes and calcium are important signaling components in plant gravitropism.

  13. The effect of gas mixing and biased disc voltage on the preglow transient of electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O.; Toivanen, V.; Komppula, J.; Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyvaeskylae, Jyvaeskylae 40500 (Finland)

    2012-02-15

    The effect of gas mixing and biased disc voltage on the preglow of electron cyclotron resonance ion source plasma has been studied with the AECR-U type 14 GHz ion source. It was found that gas mixing has a significant effect on the preglow. The extracted transient beam currents and efficiency of the heavier species increase, while the currents and efficiency of the lighter species decrease when gas mixing is applied. The effect of the biased disc was found to be pronounced in continuous operation mode in comparison to preglow. The data provide information on the time scales of the plasma processes explaining the effects of gas mixing and biased disc. The results also have implications on production of radioactive ion beams in preglow mode for the proposed Beta Beam neutrino factory.

  14. Ion cyclotron emission calculations using a 2D full wave numerical code

    Energy Technology Data Exchange (ETDEWEB)

    Batchelor, D.B.; Jaeger, E.F.; Colestock, P.L.

    1987-01-01

    Measurement of radiation in the HF band due to cyclotron emission by energetic ions produced by fusion reactions or neutral beam injection promises to be a useful diagnostic on the large devices which are entering the reactor regime of operation. A number of complications make the modelling and interpretation of such measurements difficult using conventional geometrical optics methods. In particular, the long wavelength and lack of high directivity of antennas in this frequency regime make observation of a single path across the plasma into a viewing dump impractical. Pickup antennas effectively see the whole plasma and wall reflection effects are important. The 2D full wave ICHR code has been modified to calculate wave fields due to a distribution of energetic ions in tokamak geometry. The radiation is modeled as due to an ensemble of localized source currents distributed in space. The spatial structure of the coherent wave field is then calculated including cyclotron harmonic damping as compared to the usual procedure of incoherently summing powers of individual radiators. This method has the advantage that phase information from localized radiating currents is globally retained so the directivity of the pickup antennas is correctly represented. Also, standing waves and wall reflections are automatically included.

  15. Ion cyclotron emission calculations using a 2D full wave numerical code

    Energy Technology Data Exchange (ETDEWEB)

    Batchelor, D.B.; Jaeger, E.F.; Colestock, P.L.

    1987-09-01

    Measurement of radiation in the HF band due to cyclotron emission by energetic ions produced by fusion reactions or neutral beam injection promises to be a useful diagnostic on large devices which are entering the reactor regime of operation. A number of complications make the modelling and interpretation of such measurements difficult using conventional geometrical optics methods. In particular the long wavelength and lack of high directivity of antennas in this frequency regime make observation of a single path across the plasma into a viewing dump impractical. Pickup antennas effectively see the whole plasma and wall reflection effects are important. We have modified our 2D full wave ICRH code/sup 2/ to calculate wave fields due to a distribution of energetic ions in tokamak geometry. The radiation is modeled as due to an ensemble of localized source currents distributed in space. The spatial structure of the coherent wave field is then calculated including cyclotron harmonic damping as compared to the usual procedure of incoherently summing powers of individual radiators. This method has the advantage that phase information from localized radiating currents is globally retained so the directivity of the pickup antennas is correctly represented. Also standing waves and wall reflections are automatically included.

  16. Ion cyclotron emission calculations using a 2D full wave numerical code

    Science.gov (United States)

    Batchelor, D. B.; Jaeger, E. F.; Colestock, P. L.

    1987-09-01

    Measurement of radiation in the HF band due to cyclotron emission by energetic ions produced by fusion reactions or neutral beam injection promises to be a useful diagnostic on large devices which are entering the reactor regime of operation. A number of complications make the modelling and interpretation of such measurements difficult using conventional geometrical optics methods. In particular the long wavelength and lack of high directivity of antennas in this frequency regime make observation of a single path across the plasma into a viewing dump impractical. Pickup antennas effectively see the whole plasma and wall reflection effects are important. We have modified our 2D full wave ICRH code2 to calculate wave fields due to a distribution of energetic ions in tokamak geometry. The radiation is modeled as due to an ensemble of localized source currents distributed in space. The spatial structure of the coherent wave field is then calculated including cyclotron harmonic damping as compared to the usual procedure of incoherently summing powers of individual radiators. This method has the advantage that phase information from localized radiating currents is globally retained so the directivity of the pickup antennas is correctly represented. Also standing waves and wall reflections are automatically included.

  17. Design of a second cyclotron harmonic gyrotron oscillator with photonic band-gap cavity

    Energy Technology Data Exchange (ETDEWEB)

    Liu Gaofeng; Chen Xiaoan; Tang Changjian, E-mail: angelchen765@163.com [College of Physical Science and Technology of Sichuan University, Chengdu 610065 (China)

    2011-07-27

    A photonic band-gap cavity (PBGC) gyrotron with a frequency of about 98 GHz is designed. Theoretical analyses and numerical calculations are made for the PBGC operating at fundamental and second cyclotron harmonic with a TE{sub 34} waveguide mode to demonstrate the beam-wave interaction. The results show that mode competition is successfully eliminated in the PBGC using mode selectivity and choosing the appropriate operating parameters. As a result, the second harmonic PBGC gyrotron operating at TE{sub 34} mode achieves a higher output efficiency than that of the fundamental. It is also demonstrated that, in the case of the chosen parameters for TE{sub 34} waveguide mode, the use of PBG structure in the second harmonic gyrotron brings about not only a lower operating B-field but also a weaker mode competition. The results show that the high-order electromagnetic mode can be developed to interact with the high cyclotron harmonic using the selectivity of the PBGC, which gives an encouraging outlook for the development of high-harmonic gyrotrons.

  18. Direct Technetium radiopharmaceuticals production using a 30MeV Cyclotron

    Directory of Open Access Journals (Sweden)

    M Kamali Dehgan

    2011-07-01

    Full Text Available Background and purpose of the study: Technetium-99m is the major radionuclide used in the world and mainly is provided by fission product. However extensive research has been conducted on the use of accelerators for production of 99mTc. This investigation reports the production of 99mTc radioisotope using cyclotrons followed by the preparation, quality control and biodistribution studies of four major Tc-radiopharmaceuticals. Methods: The high purity molybdenum natural target (130mg/cm2 was irradiated in a Cyclone 30 accelerator using 160 µA of 25 MeV proton beam energy for 1000 µA-h. After dissolution, the technetium radionuclides were extracted using methyl ethyl ketone (MEK followed by preparation of Tc-MIBI, Tc-DTPA, Tc-DMSA and Tc-phytate as radiopharmaceutical samples. Results: The results of quality controls and animal biodistribution studies showed successful production of Tc radionuclides (including 99mTc in the bombarded target and subsequent labelling of the kit with Tc. Conclusion: The developed high power Mo target if constructed using enriched 100Mo, could be a practical method for large-scale production of 99mTc and promising as an alternative to fission product 99Mo-99mTc generators for local applications near cyclotron facilities.

  19. A strong-focusing 800 MeV cyclotron for high-current applications

    Science.gov (United States)

    Pogue, N.; Assadi, S.; Badgley, K.; Comeaux, J.; Kellams, J.; McInturff, A.; McIntyre, P.; Sattarov, A.

    2013-04-01

    A superconducting strong-focusing cyclotron (SFC) is being developed for high-current applications. It incorporates four innovations. Superconducting quarter-wave cavities are used to provide >20 MV/turn acceleration. The orbit separation is thereby opened so that bunch-bunch interactions between successive orbits are eliminated. Quadrapole focusing channels are incorporated within the sectors so that alternating-gradient strong-focusing transport is maintained throughout. Dipole windings on the inner and outer orbits provide enhanced control for injection and extraction of bunches. Finally each sector magnet is configured as a flux-coupled stack of independent apertures, so that any desired number of independent cyclotrons can be integrated within a common footprint. Preliminary simulations indicate that each SFC should be capable of accelerating 10 mA CW to 800 MeV with very low loss and >50% energy efficiency. A primary motivation for SFC is as a proton driver for accelerator-driven subcritical fission in a molten salt core. The cores are fueled solely with the transuranics from spent nuclear fuel from a conventional nuclear power plant. The beams from one SFC stack would destroy all of the transuranics and long-lived fission products that are produced by a GWe reactor [1]. This capability offers the opportunity to close the nuclear fuel cycle and provide a path to green nuclear energy.

  20. Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities.

    Science.gov (United States)

    Tarvainen, O; Laulainen, J; Komppula, J; Kronholm, R; Kalvas, T; Koivisto, H; Izotov, I; Mansfeld, D; Skalyga, V

    2015-02-01

    Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum Bmin-field in single frequency heating mode is often ≤0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

  1. Development of electron cyclotron emission imaging system on the HL-2A tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, M.; Shi, Z. B.; Liu, Z. T.; Ding, X. T.; Li, J.; Zhong, W. L.; Chen, W.; Che, Y. L.; Fu, B. Z.; Cui, Z. Y.; Sun, P.; Liu, Y.; Yang, Q. W.; Duan, X. R. [Southwestern Institute of Physics, P. O. Box 432, Chengdu 610041 (China); Che, S.; Domier, C. W.; Luhmann, N. C. Jr.; Hu, X.; Spear, A. [Department of Electrical and Computer Engineering, University of California at Davis, Davis, California 95616 (United States)

    2013-11-15

    A 2D electron cyclotron emission imaging (ECEI) system has been developed for measurement of electron temperature fluctuations in the HL-2A tokamak. It is comprised of a front-end 24 channel heterodyne imaging array with a tunable RF range spanning 75–110 GHz, and a set of back-end ECEI electronics that together generate 24 × 8 = 192 channel images of the 2nd harmonic X-mode electron cyclotron emission from the HL-2A plasma. The simulated performance of the local oscillator (LO) optics and radio frequency (RF) optics is presented, together with the laboratory characterization results. The Gaussian beams from the LO optics are observed to properly cover the entire detector array. The ECE signals from the plasma are mixed with the LO signal in the array box, then delivered to the electronics system by low-loss microwave cables, and finally to the digitizers. The ECEI system can achieve temporal resolutions of ∼μs, and spatial resolutions of 1 cm (radially) and 2 cm (poloidally)

  2. Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O., E-mail: olli.tarvainen@jyu.fi; Laulainen, J.; Komppula, J.; Kronholm, R.; Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyväskylä, 40500 Jyväskylä (Finland); Izotov, I.; Mansfeld, D. [Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Skalyga, V. [Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., 603950 Nizhny Novgorod (Russian Federation)

    2015-02-15

    Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum B{sub min}-field in single frequency heating mode is often ≤0.8B{sub ECR}, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

  3. Influence of visualization on consumption during on-line shopping

    OpenAIRE

    Hictaler, Urška

    2013-01-01

    This diploma work studies the influence of visualization on consumption during on-line shopping. The first part of the thesis starts with key areas of visualization, consumption and on-line shopping. Visualization, areas of use, human perception and ways of product presentation in on-line shops are defined discussed first. Next, consumption, consumers and factors that influence their decisions and satisfaction are defined. The last topic in the first part of the thesis discusses on-line shopp...

  4. On-Line Learning: One Way to Bring People Together

    Science.gov (United States)

    Goff-Kfouri, Carol Ann

    2006-01-01

    The purpose of this study was to demonstrate the benefits of on-line learning for adult learners and to further demystify three common misconceptions concerning on-line learning: students certainly do receive support from their on-line professors, the professor is pro-active rather than passive, and students may be more motivated to learn than in…

  5. A Distributed System for Learning Programming On-Line

    Science.gov (United States)

    Verdu, Elena; Regueras, Luisa M.; Verdu, Maria J.; Leal, Jose P.; de Castro, Juan P.; Queiros, Ricardo

    2012-01-01

    Several Web-based on-line judges or on-line programming trainers have been developed in order to allow students to train their programming skills. However, their pedagogical functionalities in the learning of programming have not been clearly defined. EduJudge is a project which aims to integrate the "UVA On-line Judge", an existing…

  6. Study of the source term of radiation of the CDTN GE-PET trace 8 cyclotron with the MCNPX code

    Energy Technology Data Exchange (ETDEWEB)

    Benavente C, J. A.; Lacerda, M. A. S.; Fonseca, T. C. F.; Da Silva, T. A. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Vega C, H. R., E-mail: jhonnybenavente@gmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-10-15

    Full text: The knowledge of the neutron spectra in a PET cyclotron is important for the optimization of radiation protection of the workers and individuals of the public. The main objective of this work is to study the source term of radiation of the GE-PET trace 8 cyclotron of the Development Center of Nuclear Technology (CDTN/CNEN) using computer simulation by the Monte Carlo method. The MCNPX version 2.7 code was used to calculate the flux of neutrons produced from the interaction of the primary proton beam with the target body and other cyclotron components, during 18F production. The estimate of the source term and the corresponding radiation field was performed from the bombardment of a H{sub 2}{sup 18}O target with protons of 75 μA current and 16.5 MeV of energy. The values of the simulated fluxes were compared with those reported by the accelerator manufacturer (GE Health care Company). Results showed that the fluxes estimated with the MCNPX codes were about 70% lower than the reported by the manufacturer. The mean energies of the neutrons were also different of that reported by GE Health Care. It is recommended to investigate other cross sections data and the use of physical models of the code itself for a complete characterization of the source term of radiation. (Author)

  7. First operation and effect of a new tandem-type ion source based on electron cyclotron resonance

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Yushi, E-mail: kato@eei.eng.osaka-u.ac.jp; Kimura, Daiju; Yano, Keisuke; Kumakura, Sho; Imai, Youta; Nishiokada, Takuya; Nagaya, Tomoki; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu [Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2016-02-15

    A new tandem type source has been constructed on the basis of electron cyclotron resonance plasma for producing synthesized ion beams in Osaka University. Magnetic field in the first stage consists of all permanent magnets, i.e., cylindrically comb shaped one, and that of the second stage consists of a pair of mirror coil, a supplemental coil and the octupole magnets. Both stage plasmas can be individually operated, and produced ions in which is energy controlled by large bore extractor also can be transported from the first to the second stage. We investigate the basic operation and effects of the tandem type electron cyclotron resonance ion source (ECRIS). Analysis of ion beams and investigation of plasma parameters are conducted on produced plasmas in dual plasmas operation as well as each single operation. We describe construction and initial experimental results of the new tandem type ion source based on ECRIS with wide operation window for aiming at producing synthesized ion beams as this new source can be a universal source in future.

  8. Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mascali, David, E-mail: davidmascali@lns.infn.it; Castro, Giuseppe; Celona, Luigi; Neri, Lorenzo; Gammino, Santo [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Biri, Sándor; Rácz, Richárd; Pálinkás, József [Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/c, H-4026 Debrecen (Hungary); Caliri, Claudia [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Università degli Studi di Catania, Dip.to di Fisica e Astronomia, via Santa Sofia 64, 95123 Catania (Italy); Romano, Francesco Paolo [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); CNR, Istituto per i Beni Archeologici e Monumentali, Via Biblioteca 4, 95124 Catania (Italy); Torrisi, Giuseppe [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Università Mediterranea di Reggio Calabria, DIIES, Via Graziella, I-89100 Reggio Calabria (Italy)

    2016-02-15

    An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

  9. On-Line Impact Load Identification

    Directory of Open Access Journals (Sweden)

    Krzysztof Sekuła

    2013-01-01

    Full Text Available The so-called Adaptive Impact Absorption (AIA is a research area of safety engineering devoted to problems of shock absorption in various unpredictable scenarios of collisions. It makes use of smart technologies (systems equipped with sensors, controllable dissipaters and specialised tools for signal processing. Examples of engineering applications for AIA systems are protective road barriers, automotive bumpers or adaptive landing gears. One of the most challenging problems for AIA systems is on-line identification of impact loads, which is crucial for introducing the optimum real-time strategy of adaptive impact absorption. This paper presents the concept of an impactometer and develops the methodology able to perform real-time impact load identification. Considered dynamic excitation is generated by a mass M1 impacting with initial velocity V0. An analytical formulation of the problem, supported with numerical simulations and experimental verifications is presented. Two identification algorithms based on measured response of the impacted structure are proposed and discussed. Finally, a concept of the AIA device utilizing the idea of impactometer is briefly presented.

  10. SOL: INNOVACIÓN ON-LINE

    Directory of Open Access Journals (Sweden)

    Rubén Faúndez

    2007-11-01

    Full Text Available Las aplicaciones de simulación tienden a ser cada vez más cercanas a usuarios e industrias. Sin embargo, muchas de ellas no poseen ni la capacidad ni el conocimiento como para desarrollar internamente sus modelos de simulación. Por este motivo, y como una forma de apoyar la toma de decisiones basándose en modelos de simulación, se presenta la plataforma SOL (Simulación On Line. La metodología completa de trabajo, así como la interacción entre SOL, Empresa y Asesor, son presentadas. Su base de datos, los niveles de usuarios, sus funcionalidades, y la creación automatizada de información grafica y visual, también son explicadas. En el caso de aplicación, el uso de SOL para apoyar la toma de decisiones en una operación de movimiento de material, permite a los tomadores de decisión acceder a análisis robustos basados en información extraída de los modelos de simulación. SOL, al almacenar información, funcionar vía web, generar análisis automatizados y crear visualizaciones, permite cumplir con las expectativas de los usuarios respecto a una solución integral en simulación.

  11. Cyclotron-based of plant gravisensing

    Science.gov (United States)

    Kordyum, E.; Kalinina, Ia.; Bogatina, N.; Kondrachuk, A.

    Roots exhibit positive gravitropism they grow in the direction of a gravitational vector while shoots respond negatively and grow opposite to a gravitational vector We first demonstrated the inversion of roots gravitropism from positive to negative one under gravistimulation in the weak combined magnetic field WCMF consisted of permanent magnetic field PMF with the magnitude of order of 50 mu T and altering magnetic field AMF with the 6 mu T magnitude and a frequency of 32 Hz It was found that the effect of inversion has a resonance nature It means that in the interval of frequencies 1-45 Hz inversion of root gravitropism occurs only at frequency 32 Hz 2-3-day old cress seedlings were gravistimulated in moist chambers which are placed in mu -metal shields Inside mu -metal shields combined magnetic fields have been created The magnitude of magnetic fields was measured by a flux-gate magnetometer Experiments were performed in darkness at temperature 20 pm 1 0 C We measured the divergence angle of a growing root from its horizontal position After 1 h of gravistimulation in the WCMF we observed negative gravitropism of cress roots i e they grow in the opposite direction to a gravitational vector Frequency of 32 Hz for the magnitude of the PMF applied formally corresponds to cyclotron frequency of Ca 2 ions This indicates possible participation of calcium ions in root gravitropism There are many evidences of resonance effects of the WCMF on the biological processes that involve Ca 2 but the nature of

  12. Potential applications of a new microwave ECR (electron cyclotron resonance) multicusp plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.

    1990-01-01

    A new microwave electron cyclotron resonance (ECR) multicusp plasma ion source using two ECR plasma production regions and multicusp plasma confinement has been developed at Oak Ridge National Laboratory. This source has been operated to produce uniform and dense plasmas over large areas of 300 to 400 cm{sup 2}. The plasma source has been operated with continuous argon gas feed and pulsed microwave power. The discharge initiation phenomena and plasma properties have been investigated and studied as functions of discharge parameters. Together with the discharge characteristics observed, a hypothetical discharge mechanism for this plasma source is reported and discussed. Potential applications, including plasma and ion-beam processing for manufacturing advanced microelectronics and for space electric propulsion, are discussed. 7 refs., 6 figs.

  13. Reversed Shear Alfv'en Eigenmode Stabilization by Localized Electron Cyclotron Heating

    Science.gov (United States)

    van Zeeland, M. A.; Lohr, J.; Heidbrink, W. W.; Nazikian, R.; Solomon, W. M.; Gorelenkov, N. N.; Kramer, G. J.; Austin, M. E.; Rhodes, T. L.; Holcomb, C.; Makowski, M. A.; McKee, G. R.; Sharapov, S. E.

    2007-11-01

    Reversed shear Alfv'en eigenmode (RSAE) activity in DIII-D is observed to be stabilized by electron cyclotron heating (ECH) near the minimum of the safety factor (qmin) in neutral beam heated discharges with reversed magnetic shear. The degree of RSAE stabilization and the volume averaged neutron production (Sn) are highly dependent on ECH deposition location relative to qmin. Ideal MHD simulations predict RSAE existence during ECH, indicating that the mode disappearance is due to kinetic effects not taken into account by the ideal MHD model. While discharges with ECH stabilization of RSAEs have higher Sn than discharges with significant RSAE activity, neutron production remains strongly reduced (up to 60%), indicating the bulk of the deficit is not due to RSAEs alone.

  14. Evaluation Study for the Production of the Medical Isotope ^90Y, using a Cyclotron

    Science.gov (United States)

    Necsoiu, D.; Morgan, I. L.; Hupf, Homer; Armbruster, J.; Boyce, D.; El Bouanani, M.; McDaniel, F. D.

    2000-10-01

    The use of radioisotopes in therapy, medical imaging and laboratory tests is well-established worldwide. ^90Y is a very good therapeutic candidate for radioimmunotherapy applications. Traditionally, medical radioisotopes are produced using either nuclear reactors or proton accelerators. In this study, the medical isotope ^90Y has been produced using ^90Zr(n,p)^90Y nuclear reaction. Neutrons for the activation process were produced using ^natRh(p,xn) reaction with a 27 MeV proton beam from a cyclotron. Since ^90Y is a pure beta emitter, the gamma rays from the ^90Zr(n,2n)^89Zr reaction were used to quantify the incident neutron flux on the ^90Zr sample. Experimental results of the neutron production and ^90Y activity are presented.

  15. Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T., E-mail: uchida-t@toyo.jp [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Graduate School of Interdisciplinary New Science, Toyo University, Kawagoe 350-8585 (Japan); Rácz, R.; Biri, S. [Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/C, H-4026 Debrecen (Hungary); Muramatsu, M.; Kitagawa, A. [National Institute of Radiological Sciences (NIRS), Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, Suita 565-0871 (Japan); Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Faculty of Science and Engineering, Toyo University, Kawagoe 350-8585 (Japan)

    2016-02-15

    We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.

  16. First results of the 2.45 GHz Oshima electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Asaji, T., E-mail: asaji@nc-toyama.ac.jp [National Institute of Technology, Toyama College, 13 Hongo, Toyama 939-8630 (Japan); Nakamura, T.; Furuse, M. [National Institute of Technology, Oshima College, 1091-1 Komatsu, Suouoshima, Oshima, Yamaguchi 742-2193 (Japan); Hitobo, T. [Tateyama Machine Co., Ltd., 30 Shimonoban, Toyama 930-1305 (Japan); Uchida, T. [Graduate School of Engineering, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 (Japan); Muramatsu, M. [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2016-02-15

    A new electron cyclotron resonance ion source has been constructed at Oshima College with a 2.45 GHz magnetron microwave source and permanent magnets employed as the main components. In addition, a solid-state power amplifier with a frequency range of 2.5–6.0 GHz was installed to study two-frequency plasma heating. Three solenoid coils were set up for adjusting the axial magnetic fields. Argon plasma generation and ion beam production have been conducted during the first year of operation. Ion current densities in the ECR plasma were measured using a biased disk. For 2.45 and 4.65 GHz two-frequency plasma heating, the ion density was approximately 1.5 times higher than that of 2.45 GHz single-frequency heating.

  17. Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification

    Science.gov (United States)

    Uchida, T.; Rácz, R.; Muramatsu, M.; Kato, Y.; Kitagawa, A.; Biri, S.; Yoshida, Y.

    2016-02-01

    We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.

  18. Design of a correlation electron cyclotron emission diagnostic for Alcator C-Moda)

    Science.gov (United States)

    Sung, C.; White, A. E.; Irby, J. H.; Leccacorvi, R.; Vieira, R.; Oi, C. Y.; Peebles, W. A.; Nguyen, X.

    2012-10-01

    A correlation electron cyclotron emission (CECE) diagnostic has been installed in Alcator C-Mod. In order to measure electron temperature fluctuations, this diagnostic uses a spectral decorrelation technique. Constraints obtained with nonlinear gyrokinetic simulations guided the design of the optical system and receiver. The CECE diagnostic is designed to measure temperature fluctuations which have kθ ≤ 4.8 cm-1 (kθρs < 0.5) using a well-focused beam pattern. Because the CECE diagnostic is a dedicated turbulence diagnostic, the optical system is also flexible, which allows for various collimating lenses and antenna to be used. The system overview and the demonstration of its operability as designed are presented in this paper.

  19. Design of a new tracking device for on-line dose monitor in ion therapy

    CERN Document Server

    Traini, Giacomo; Bollella, Angela; Collamati, Francesco; De Lucia, Erika; Faccini, Riccardo; Ferroni, Fernando; Frallicciardi, Paola Maria; Mancini-Terracciano, Carlo; Marafini, Michela; Mattei, Ilaria; Miraglia, Federico; Muraro, Silvia; Paramatti, Riccardo; Piersanti, Luca; Pinci, Davide; Rucinski, Antoni; Russomando, Andrea; Sarti, Alessio; Sciubba, Adalberto; Senzacqua, Martina; Solfaroli-Camillocci, Elena; Toppi, Marco; Voena, Cecilia; Patera, Vincenzo

    2016-01-01

    Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam interactions in the patient tissues. In fact, the charged particle emission shape can be correlated with the spatial dose release and the Bragg peak position. The detector uses the information provided by 12 layers of scintillating fibers followed by a plastic scintillator and a small calorimeter made of a pixelated Lutetium Fine Silicate crystal. Simulations have been performed to evaluate the achievable spatial resolution and a possible application of the device for the monitoring of the dose pro?le in a real treatment is presented.

  20. The LHC Logging Service : Handling terabytes of on-line data

    CERN Document Server

    Roderick, C; Gaspar Aparicio, R D; Grancher, E; Khodabandeh, A; Segura Chinchilla, N

    2009-01-01

    Based on previous experience with LEP, a long-term data logging service for the LHC was developed and put in place in 2003, several years before beam operation. The scope of the logging service covers the evolution over time of data acquisitions on accelerator equipment and beam related parameters. The intention is to keep all this time-series data on-line for the lifetime of LHC, allowing easy data comparisons with previous years. The LHC hardware commissioning has used this service extensively prior to the first beams in 2008 and even more so in 2009. Current data writing rates exceed 15TB/year and continue to increase. The high data volumes and throughput rates, in writing as well as in reading, require special arrangements on data organization and data access methods.