WorldWideScience

Sample records for oil-refrigerant r12 mixture

  1. Behavior of FFC refrigerants in the presence of refrigerant oils. Oelverhalten chlorfreier Kaeltemittel

    Energy Technology Data Exchange (ETDEWEB)

    Burke, M.; Kruse, H. (Hannover Univ. (Germany, F.R.). Inst. fuer Kaeltetechnik und Angewandte Waermetechnik)

    1990-01-01

    Looking for substitutes for the ozone-depleting refrigerants R12 and R22, investigations were made of the miscibility of FFC refrigerants (R23 - trifluoromethane CHF{sub 3}, R134a - tetrafluoroethane CH{sub 3}-CHF{sub 2}, and R152a - difluoroethane CH{sub 3}-CHF{sub 2}) with refrigerator oils. First experimental results reveal the refrigerants' behavior when mixed with mineral oils, alkylbenzene, PAG and ester-based oils. Mixtures of above refrigerants, especially R134a/R152a and R23/R152a as binary nonazeotropic mixtures, are considered conceivable substitutes. While addition of R23 reduces the mixture's flammability, addition of R152a improves the solubility of R134a in refrigerant oils. (orig./HW).

  2. Thermodynamic analysis of a novel exhaust heat-driven non-adiabatic ejection-absorption refrigeration cycle using R290/oil mixture

    International Nuclear Information System (INIS)

    Li, Keqiao; Cai, Dehua; Liu, Yue; Jiang, Jingkai; Sun, Wei; He, Guogeng

    2017-01-01

    Graphical abstract: A novel air-cooled non-adiabatic ejection-absorption refrigeration cycle using R290/refrigeration oil has been thermodynamically analyzed. Influences of the ejector and the non-adiabatic absorber applications on the system performance and other system operation parameters have been investigated. The simulation results will be of great help to the miniaturization and practical application of the air-cooled absorption refrigeration system. - Highlights: • A novel air-cooled non-adiabatic ejection-absorption refrigeration cycle is proposed. • Influences of the ejector and the air-cooled non-adiabatic absorber applications on the system performance are investigated. • Variations of system performance and other system operation parameters are investigated. • R290/refrigeration oil mixture used as working pairs is analyzed. - Abstract: This paper thermodynamically analyzes a novel air-cooled non-adiabatic ejection-absorption refrigeration cycle with R290/oil mixture driven by exhaust heat. An ejector located at the upstream of the non-adiabatic absorber is employed to improve the cycle performance. Variations of COP, circulation ratio and component heat load of the system as a function of generating temperature, pressure ratio, absorption temperature, condensing temperature and evaporating temperature have been investigated in this work. The simulation results show that, compared with the conventional absorption refrigeration cycle, this non-adiabatic ejection-absorption refrigeration cycle has higher absorption efficiency, better performance, wider working condition range and lower total heat load and its COP can reach as high as 0.5297. The implementation of the ejector and the non-adiabatic absorber helps to realize the miniaturization and wider application of the absorption refrigeration system. In addition, R290/oil mixture is a kind of highly potential working pairs for absorption refrigeration.

  3. On-road performance analysis of R134a/R600a/R290 refrigerant mixture in an automobile air-conditioning system with mineral oil as lubricant

    International Nuclear Information System (INIS)

    Ravikumar, T.S.; Mohan Lal, D.

    2009-01-01

    R134a has been accepted as the single major refrigerant in the automobile industry and it has been used worldwide. But, the problem associated with it is the use of the PAG oil as the lubricant. Unlike the conventional mineral oil, the synthetic PAG oil used with R134a is highly hygroscopic in nature. The PAG lubricants come with different additives unique for different compressors. This leads to serious service issues. Therefore, a refrigerant, which will be readily available to replace R12, and also compatible with mineral oil, is needed. In the present study the readily available R134a is used in place of R12. However, to avoid PAG oil and to use the conventional mineral oil as lubricant, R134a is mixed with the commercially available hydrocarbon blend, (45.2% R290 and 56.8% R600a) in the proportion of 91% and 9%, respectively by mass. The quantity of hydrocarbons used is well below the lower flammable limit. This new mixture R134a/R600a/R290 is tested in the air-conditioning system of a passenger car 'on road' in the true running conditions and compared with the results that has been obtained with R12. The cool down performance under varying speed and varying ambient conditions, system performance under severe accelerating conditions and bumper-to-bumper traffic conditions is studied. The test results show that the new blend can be a promising substitute for the existing R12 systems and it can eliminate the use of hygroscopic PAG oil.

  4. Component-wise exergy and energy analysis of vapor compression refrigeration system using mixture of R134a and LPG as refrigerant

    Science.gov (United States)

    Gill, Jatinder; Singh, Jagdev

    2017-11-01

    In this work, the experimental examination was carried out using a mixture of R134a and LPG refrigerant (consisting of R134a and LPG in a proportion of 28:72 by weight) as a replacement for R134a in a vapor compression refrigeration system. Exergy and energy tests were carried out at different evaporator and condenser temperatures with controlled environmental conditions. The results showed that the exergy destruction in the compressor, condenser, evaporator, and a capillary tube of the R134a / LPG refrigeration system was found lower by approximately 11.13-3.41%, 2.24-3.43%, 12.02-13.47% and 1.54-5.61% respectively. The compressor exhibits the highest level of destruction, accompanied by a condenser, an evaporator and a capillary tube in refrigeration systems. The refrigeration capacity, COP and power consumption of the compressor of the R134a /LPG refrigeration system were detected higher and lower compared to the R134a refrigeration system by about 7.04-11.41%, 15.1-17.82%, and 3.83-8.08% respectively. Also, the miscibility of R134a and LPG blend with mineral oil discovered good. The R134a and LPG refrigerant mixture proposed in this study perform superior to R134a from component-wise exergy and energy analyses under similar experimental conditions.

  5. Component-wise exergy and energy analysis of vapor compression refrigeration system using mixture of R134a and LPG as refrigerant

    Science.gov (United States)

    Gill, Jatinder; Singh, Jagdev

    2018-05-01

    In this work, the experimental examination was carried out using a mixture of R134a and LPG refrigerant (consisting of R134a and LPG in a proportion of 28:72 by weight) as a replacement for R134a in a vapor compression refrigeration system. Exergy and energy tests were carried out at different evaporator and condenser temperatures with controlled environmental conditions. The results showed that the exergy destruction in the compressor, condenser, evaporator, and a capillary tube of the R134a / LPG refrigeration system was found lower by approximately 11.13-3.41%, 2.24-3.43%, 12.02-13.47% and 1.54-5.61% respectively. The compressor exhibits the highest level of destruction, accompanied by a condenser, an evaporator and a capillary tube in refrigeration systems. The refrigeration capacity, COP and power consumption of the compressor of the R134a /LPG refrigeration system were detected higher and lower compared to the R134a refrigeration system by about 7.04-11.41%, 15.1-17.82%, and 3.83-8.08% respectively. Also, the miscibility of R134a and LPG blend with mineral oil discovered good. The R134a and LPG refrigerant mixture proposed in this study perform superior to R134a from component-wise exergy and energy analyses under similar experimental conditions.

  6. Thermodynamic performance of R502 alternative refrigerant mixtures for low temperature and transport applications

    International Nuclear Information System (INIS)

    Park, Ki-Jung; Jung, Dongsoo

    2007-01-01

    In this study, two pure hydrocarbon refrigerants, R1270 (propylene) and R290 (propane), and three binary mixtures composed of R1270, R290 and R152a were tested in a refrigerating bench tester with a scroll compressor in an attempt to substitute R502, which is used in most low temperature and transport refrigeration applications. The test bench provided 3-3.5 kW capacity, and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions, resulting in the average saturation temperatures of -28 and 45 o C in the evaporator and condenser, respectively. The test results showed that all refrigerants tested had 9.6-18.7% higher capacity and 17.1-27.3% higher COP than R502. The compressor discharge temperature of R1270 was similar to that of R502, while those of all the other refrigerants were 23.7-27.9 o C lower than that of R502. For all alternative refrigerants, the charge was reduced up to 60% as compared to R502. There, of course, was no problem with mineral oil, since the mixtures were mainly composed of hydrocarbons. Since some of them are mixtures, one can change their compositions a little to suit various needs in many applications without significant deterioration of the performance. Overall, these alternative refrigerants offer better system performance and reliability than R502 and can be used as long term substitutes for R502 due to their excellent environmental properties

  7. Influence of Oil on Refrigerant Evaporator Performance

    Science.gov (United States)

    Kim, Jong-Soo; Nagata, Karsuya; Katsuta, Masafumi; Tomosugi, Hiroyuki; Kikuchi, Kouichiro; Horichi, Toshiaki

    In vapor compression refrigeration system using oil-lubricated compressors, some amount of oil is always circulated through the system. Oil circulation can have a significant influence on the evaporator performance of automotive air conditioner which is especially required to cool quickly the car interior after a period standing in the sun. An experimental investigation was carried out an electrically heated horizontal tube to measure local heat transfer coefficients for various flow rates and heat fluxes during forced convection boiling of pure refrigerant R12 and refrigerant-oil mixtures (0-11% oil concentration by weight) and the results were compared with oil free performance. Local heat transfer coefficients increased at the region of low vapor quality by the addition of oil. On the other hand, because the oil-rich liquid film was formed on the heat transfer surface, heat transfer coefficients gradually decreased as the vapor quality became higher. Average heat transfer coefficient reached a maximum at about 4% oil concentration and this trend agreed well with the results of Green and Furse. Previous correlations, using the properties of the refrigerant-oil mixture, could not predict satisfactorily the local heat transfer coefficients data. New correlation modified by oil concentration factor was developed for predicting the corresponding heat transfer coefficient for refrigerant-oil mixture convection boiling. The maximum percent deviation between predicted and measured heat transfer coefficient was within ±30%.

  8. Performance analysis of the reciprocating compressor with hydrocarbon refrigerant mixtures, R290/R600a

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.H.; Chung, Y.G.; Pak, H.Y. [Hanyang University, Seoul (Korea); Park, K.W. [LG Industrial Systems, Seoul (Korea)

    1999-03-01

    A performance analysis simulation program that can be applied to a hermetic reciprocating compressor with various refrigerants has been developed. For the numerical analysis, the passage of refrigerant in compressor is subdivided into control volumes. Instead of the ideal gas assumption, CSD equation of state is applied to calculate the thermodynamic properties of refrigerants. To verify the validity of developed program, the result has been compared with the experimental data served by the compressor supplier. The performance of each refrigerant and the possibility of direct application are estimated by applying R12, 134a, R290, R600a and R290/R600a mixture to an existing compressor. Also, parametric study for various crank rotating speeds and the mole fractions of refrigerant has been performed. 22 refs., 12 figs., 5 tabs.

  9. Dynamics of gas bubble growth in oil-refrigerant mixtures under isothermal decompression

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Joao Paulo; Barbosa Junior, Jader R.; Prata, Alvaro T. [Federal University of Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. of Mechanical Engineering], Emails: jpdias@polo.ufsc.br, jrb@polo.ufsc.br, prata@polo.ufsc.br

    2010-07-01

    This paper proposes a numerical model to predict the growth of gaseous refrigerant bubbles in oil-refrigerant mixtures with high contents of oil subjected to isothermal decompression. The model considers an Elementary Cell (EC) in which a spherical bubble is surrounded by a concentric and spherical liquid layer containing a limited amount of dissolved liquid refrigerant. The pressure reduction in the EC generates a concentration gradient at the bubble interface and the refrigerant is transported to the bubble by molecular diffusion. After a sufficiently long period of time, the concentration gradient in the liquid layer and the bubble internal pressure reach equilibrium and the bubble stops growing, having attained its stable radius. The equations of momentum and chemical species conservation for the liquid layer, and the mass balance at the bubble interface are solved via a coupled finite difference procedure to determine the bubble internal pressure, the refrigerant radial concentration distribution and the bubble growth rate. Numerical results obtained for a mixture of ISO VG10 ester oil and refrigerant HFC-134a showed that bubble growth dynamics depends on model parameters like the initial bubble radius, initial refrigerant concentration in the liquid layer, decompression rate and EC temperature. Despite its simplicity, the model showed to be a potential tool to predict bubble growth and foaming which may result from important phenomena occurring inside refrigeration compressors such as lubrication of sliding parts and refrigerant degassing from the oil stored in oil sump during compressor start-up. (author)

  10. Bubble-point and dew-point equation for binary refrigerant mixture R22-R142b

    Energy Technology Data Exchange (ETDEWEB)

    Liancheng Tan; Zhongyou Zhao; Yonghong Duan (Xi' an Jiaotong Univ., Xi' an (China). Dept. of Power Machinery Engineering)

    1992-01-01

    A bubble-point and dew-point equation (in terms either of temperature or of pressure is suggested for the refrigerant mixture R22-R142b), which is regarded as one of the alternatives to R12. This equation has been examined with experimental data. A modified Rackett equation for the calculation of the bubble-point volume is also proposed. Compared with the experimental data, the rms errors in the calculated values of the bubble-point temperature, the dew-point temperature, and the bubble-point volume are 1.093%, 0.947%, and 1.120%, respectively. The calculation covers a wide range of temperatures and pressures, even near the critical point. It is shown how the equations are extrapolated to calculate other binary refrigerant mixtures. (author)

  11. The application of hydrocarbon refrigerant mixtures in a hermetic reciprocating compressor for high back pressure conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.M.; Pak, H.Y. [Hanyang University, Seoul (Korea)

    1999-03-01

    The application of hydrocarbon refrigerant mixtures in a hermetic reciprocating compressor for dehumidifier is investigated. The selected refrigerants are R12, R134a, HC-Blend(R290/R600a), CX(R152a/R600a) and OS-12a. Both theoretical and experimental investigations have been performed for the selected refrigerants. The test results of hydrocarbon refrigerants have been compared to traditional refrigerant(R12) and R134a. The results show that hydrocarbon refrigerant mixtures(HC-Blend, CX and OS-12a) are very good alternatives in the refrigeration system for R12 and R134a. 11 refs., 3 fig., 12 tabs.

  12. Condensation heat transfer for refrigerant-oil mixtures in microfin tube condenser

    Energy Technology Data Exchange (ETDEWEB)

    Cho, K N [Sungkyunkwan University, Seoul (Korea); Tae, S J [Sungkyunkwan University Graduate School, Seoul (Korea)

    2000-04-01

    Condensation heat transfer experiments for R-22 and R-407 C refrigerants mixed with mineral oil and POE oil respectively were performed in straight and U-bend sections of a microfin tube. Experimental parameters were an oil concentration from 0 to 5 %, a mass flux from 100 to 400 kg/m{sup 2}s and an inlet quality from 0.5 to 0.9. The enhancement factors for R-22 and R-407 C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as the mass maximum at the 90 deg. position. The heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33 % than the average heat transfer coefficients at the first straight section. (author). 10 refs., 6 figs., 1 tab.

  13. Flow condensation pressure drop characteristics of R410A-oil mixture inside small diameter horizontal microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiangchao; Ding, Guoliang; Hu, Haitao; Zhu, Yu [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Gao, Yifeng [International Copper Association Shanghai Office, Shanghai 200020 (China); Deng, Bin [Institute of Heat Transfer Technology, Golden Dragon Precise Copper Tube Group Inc., Shanghai 200135 (China)

    2010-11-15

    Flow condensation pressure drop characteristics of R410A-oil mixture inside small diameter (5.0 mm and 4.0 mm O.D.) horizontal microfin tubes were investigated experimentally covering nominal oil concentrations from 0% to 5%. The research results indicate that, comparing with the frictional pressure drop of pure R410A, the frictional pressure drop of R410A-oil mixture may decrease by maximum of 18% when the vapor quality is lower than 0.6, and increase by maximum of 13% when the vapor quality is higher than 0.6. A new frictional pressure drop correlation for R410A-oil mixture flow condensation inside microfin tubes is developed based on the refrigerant-oil mixture properties, and can agree with 94% of the experimental data within a deviation of -30% to +30%. (author)

  14. Assessment of propane/commercial butane mixtures as possible alternatives to R134a in domestic refrigerators

    International Nuclear Information System (INIS)

    Fatouh, M.; El Kafafy, M.

    2006-01-01

    The possibility of using hydrocarbon mixtures as working fluids to replace R134a in domestic refrigerators has been evaluated through a simulation analysis in the present work. The performance characteristics of domestic refrigerators were predicted over a wide range of evaporation temperatures (-35 to -10 o C) and condensation temperatures (40-60 deg. C) for various working fluids such as R134a, propane, commercial butane and propane/iso-butane/n-butane mixtures with various propane mass fractions. The performance characteristics of the considered domestic refrigerator were identified by the coefficient of performance (COP), volumetric cooling capacity, cooling capacity, condenser capacity, input power to compressor, discharge temperature, pressure ratio and refrigerant mass flow rate. The results showed that pure propane could not be used as a drop in replacement for R134a in domestic refrigerators because of its high operating pressures and low COP. Commercial butane yields many desirable characteristics but requires a compressor change. The coefficient of performance of the domestic refrigerator using a ternary hydrocarbon mixture with propane mass fractions from 0.5 to 0.7 is higher than that of R134a. Comparison among the considered working fluids confirmed that the average refrigerant mass flow rate of the propoane/commercial butane mixture is 50% lower than that of R134a. Also, the results indicated that R134a and the propoane/commercial butane mixture with 60% propane mass concentration have approximately the same values of saturation pressure, compressor discharge temperature, condenser heat load, input power, cooling capacity and volumetric cooling capacity. However, the pressure ratio of the hydrocarbon mixture with 60% propane is lower than that of R134a by about 11.1%. Finally, the reported results confirmed that the propane/iso-butane/n-butane mixture with 60% propane is the best drop in replacement for R134a in domestic refrigerators under normal

  15. Study of the Vapor-Liquid Coexistence Curve and the Critical Curve for Nonazeotropic Refrigerant Mixture R152a + R114 System

    Science.gov (United States)

    Kabata, Yasuo; Higashi, Yukihiro; Uematsu, Masahiko; Watanabe, Koichi

    Measurements of the vapor-liquid coexistence curve in the critical region for the refrigerant mixture of R152a (CH3CHF2: 1, l-difluoroethane) +R 114 (CCIF2CCIF2 :1, 2-dichloro-1, 1, 2, 2-tetrafluoroethane) system were made by visual observation of the disappearance of the meniscus at the vapor-liquid interface within an optical cell. Forty-eight saturated densities along the vapor-liquid coexistence curve between 204 and 861 kg·m-3 for five different compositions of 10, 20, 50, 80 and 90 wt% R 152a were obtained in the temperature range 370 to 409 K. The experimental errors of temperature, density, and mass fraction were estimated within ±10mK, ±0.5% and +0.05 %, respectively. On the basis of these measurements, the critical parameters of five different compositions for the R 152a +R 114 system were determined in consideration of the meniscus disappearance level as well as intensity of the critical opalescence. In accordance with the previous results of three other refrigerant mixtures, i.e., R 12 +R 22 system, R 22 +R 114 system and R 13B1 + R 114 system, the coexistence curve and critical curve on the temperature-density diagram for binary refrigerant mixtures were discussed. In addition, correlations of its composition dependence for this system were proposed.

  16. Performance prediction of rotary compressor with hydrocarbon refrigerant mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Park, M.W.; Chung, Y.G. [Hanyang University Graduate School, Seoul (Korea); Park, K.W. [LG Industrial System Corporation Limited (Korea); Park, H.Y. [Hanyang University, Seoul (Korea)

    1999-04-01

    This paper presents the modeling approach that can be predicted transient behavior of rotary compressor. Mass and energy conservation laws are applied to the control volume, and real gas state equation is used to obtain thermodynamic properties of refrigerant. The valve equation is solved to analyze discharge process also. Dynamic analysis of vane and roller is carried out to gain friction work. From above modeling, the performance of rotary compressor with radial clearance and friction loss is investigated numerically. The performance of each refrigerant and the possibility of using the hydrocarbon refrigerant mixtures in an existing rotary compressor are estimated by applying R12, R134a, R290/R600a mixture also. (author). 6 refs., 13 figs., 1 tab.

  17. Energy savings with the effect of magnetic field using R290/600a mixture as substitute for CFC12 and HFC134a

    Directory of Open Access Journals (Sweden)

    Mani Kolandavel

    2008-01-01

    Full Text Available This paper presents an experimental study on the replacement of CFC12 and HFC134a by the new R290/R600a refrigerant mixture as drop-in replacement refrigerant with and without the effect of magnetic field. Without any modification to the system components drop-in experimental tests were performed on a vapour compression refrigeration system with a reciprocating compressor, which was originally designed to operate with CFC12.The test results with no magnets showed that the refrigerant R290/R600a had 19.9-50.1% higher refrigerating capacity than R12 and 28.6-87.2% than R134a. The mixture R290/R600a consumed 6.8- -17.4% more energy than R12. The coefficient of performance of R290/R600a mixture increases from 3.9-25.1% than R12 at lower evaporating temperatures and 11.8-17.6% at higher evaporating temperatures. The effect of magnetic field force reduced the compressor energy consumption by 1.5-2.5% than with no magnets. The coefficient of performance of the system was higher in the range 1.5-2.4% with the effect of magnetic field force. The R290/600a (68/32 by wt.% mixture can be considered as an excellent alternative refrigerant for CFC12 and HFC134a systems.

  18. Effects of synthetic oil in a compression refrigeration system using R410A. Part II: quality of heat transfer and pressure losses within the heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Lottin, O.; Guillemet, P. [Ecole Polytechnique de l' Universite de Nantes (France). Laboratoire de Thermocinetique; Lebreton, J-M. [Electricite de France, Moret sur Loing (France)

    2003-11-01

    The consequences of the oil rejected by the compressor of a vapour-compression refrigeration system on the operation of the evaporator and condenser are analysed. The modelled prototype uses the mixture of HFC R410A and a synthetic polyolester (POE) oil. The rise of the amount of lubricant circulating in the system leads to a progressive change in the behaviour of the mixture of refrigerant and oil that, for the higher oil mass fraction, evolves like a zeotropic mixture. One also observes that the presence of lubricant is generally associated with a fall of the performances of the heat exchangers, except however in the evaporator where an optimum is observed when the quantity of oil is equal to 0.1% of the total mass of the mixture. Some conclusions are drawn about the choice of correlations for the calculation of the refrigerant side heat transfer coefficient in a plate evaporator. (author)

  19. Thermodynamic analysis of refrigerant mixtures for possible replacements for CFCs by an algorithm compiling property data

    International Nuclear Information System (INIS)

    Arcaklioglu, Erol; Cavusoglu, Abdullah; Erisen, Ali

    2006-01-01

    In this study, we formed an algorithm to find refrigerant mixtures of equal volumetric cooling capacity (VCC) when compared to CFC based refrigerants in vapor compression refrigeration systems. To achieve this aim the point properties of the refrigerants are obtained from REFPROP where appropriate. We used replacement mixture ratios-of varying mass percentages-suggested by various authors along with our newly formed mixture ratios. In other words, we tried to see the effect of changing mass percentages of the suggested (i.e. in the literature) replacement refrigerants on the VCC of the cooling system. Secondly, we used this algorithm to calculate the coefficient of performance (COP) of the same refrigeration system. This mechanism has provided us the ability to compare the COP of the suggested refrigerant mixtures and our newly formed mixture ratios with the conventional CFC based ones. According to our results, for R12 R290/R600a (56/44) mixture, for R22 R32/R125/R134a (32.5/5/62.5) mixture, and for R502 R32/R125/R134a (43/5/52) mixture are appropriate and can be used as replacements

  20. A thermodynamic analysis of a transcritical cycle with refrigerant mixture R32/R290 for a small heat pump water heater

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jianlin; Xu, Zong; Tian, Gaolei [Department of Refrigeration and Cryogenic Engineering, School of Energy and Power Engineering, Xi' an Jiaotong University, West Xianning Road, No. 28, Xianning West Road, Xi' an Shaanxi 710049 (China)

    2010-12-15

    In this study, a thermodynamic analysis on the performance of a transcritical cycle using azeotropic refrigerant mixtures of R32/R290 with mass fraction of 70/30 has been performed. The main purpose of this study is to theoretically verify the possibility of applying the chosen refrigerant mixture in small heat pumps for high temperature water heating applications. Performance evaluation has been carried out for a simple azeotropic mixture R32/R290 transcritical cycle by varying evaporator temperature, outlet temperature of gas cooler and compressor discharge pressure. Furthermore, the effects of an internal heat exchanger on the transcritical R32/R290 cycle have been presented at different operating conditions. The results show that high heating coefficient of performance (COP{sub h}) and volumetric heating capacity can be achieved by using this transcritical cycle. It is desirable to apply the chosen refrigerant mixture R32/R290 in small heat pump water heater for high temperature water heating applications, which may produce hot water with temperature up to 90 C. (author)

  1. Heat transfer property of refrigerant-oil mixture in a flooded evaporator: The role of bubble formation and oil retention

    International Nuclear Information System (INIS)

    Koo, Kyoung-Min; Kim, Sung-Gyu; Jeong, Young-Man; Lee, Jae-Keun; Kim, Soo Hyung; Lee, Soowon; Park, Nae-Hyun; Na, Byung-Chul; Hwang, Yoon-Jae; Kim, Byung-Soon; Hwang, Joon-Hyun

    2013-01-01

    We examined the effect of oil retention on the heat transfer performance of a shell-and-tube-type evaporator which had 26 inner tubes and was filled with the refrigerant R-134a. The refrigerant was boiled on the surface of the inner tubes in the evaporator, while chilled water circulated through these tubes. An experimental apparatus was designed to measure both the pressure and temperature profiles at the inlet and outlet of the flooded evaporator. Four windows were installed for observing the operation of the flooded evaporator. A series of experiments were carried out under the following conditions: the refrigerant saturation temperature, 5 .deg. C; refrigerant inlet quality, 0.1; heat fluxes from water to the refrigerant, 5-7 kW/m"2.. The concentration of the oil retained in the refrigerant was then varied up to approximately 10% to observe the effect on the heat transfer performance of the flooded evaporator. Increasing the oil content (i.e., increasing the concentration up to a maximum of approximately 10%) in the refrigerant R134a did not lead to any appreciable reduction in the overall heat transfer coefficient of a flooded evaporator with multiple-inner-tubes. When the oil concentration in the refrigerant was approximately 10%, the heat transfer degradation in the case of the flooded evaporator with multiple-inner-tubes was approximately 11%, which was found to be much smaller than the heat transfer degradation in the case of a flooded evaporator with a single-tube (26-49%). This observation suggested that the oil retained in the refrigerant did not significantly deteriorate the heat transfer performance of the flooded evaporator, presumably because the presence of tube bundles promoted forced convection by agitating bubbles

  2. A numerical study on the oil retention of R410A and PVE oil mixture in multi heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hak Soo; Kim, Min Soo [Seoul National University, Seoul (Korea, Republic of)

    2016-04-15

    Predicting an amount of discharged oil from a compressor is necessary to charge the compressor with proper amount of oil. The amount of discharged oil can be predicted by calculating the oil retention amount in each component of a heat pump system. This study suggests a method for calculating the oil retention amount in a heat pump system. In addition, flow pattern of refrigerant and oil mixture in horizontal gas line of refrigerant was ascertained by flow visualization. The oil retention amounts in each component of multi heat pump system were calculated with respect to mass flux of refrigerant, Oil circulation ratio (OCR), length of horizontal and vertical lines. Oil retention amounts in horizontal and vertical gas lines of refrigerant were significant. To validate the model for gas lines of refrigerant, comparison between predicted and experimental oil retention amounts was conducted, and mean absolute percentage error was 15.0%.

  3. Thermodynamic performance of an auto-cascade ejector refrigeration cycle with mixed refrigerant R32 + R236fa

    International Nuclear Information System (INIS)

    Tan, Yingying; Wang, Lin; Liang, Kunfeng

    2015-01-01

    In this paper, an auto-cascade ejector refrigeration cycle (ACERC) is proposed to obtain lower refrigeration temperature based on conventional ejector refrigeration and auto-cascade refrigeration principle. The thermodynamic performance of ACERC is investigated theoretically. The zeotropic refrigerant mixture R32 + R236fa is used as its working fluid. A parametric analysis is conducted to evaluate the effects of some thermodynamic parameters on the cycle performance. The study shows that refrigerant mixture composition, condenser outlet temperature and evaporation pressure have effects on performance of ACERC. The theoretical results also indicate that the ACERC can achieve the lowest refrigeration temperature at the temperature level of −30 °C. The application of zeotropic refrigerant mixture auto-cascade refrigeration in the ejector refrigeration cycle can provide a new way to obtain lower refrigeration temperature utilizing low-grade thermal energy. - Highlights: • An auto-cascade ejector refrigerator with R32 + R236fa mixed refrigerant is proposed. • The cycle can obtain a refrigeration temperature at −30 °C temperature range. • The effects of some thermodynamic parameters on the cycle performance are evaluated

  4. Condensation heat transfer characteristics of R410A-oil mixture in 5 mm and 4 mm outside diameter horizontal microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiangchao; Ding, Guoliang; Hu, Haitao; Zhu, Yu [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Gao, Yifeng [International Copper Association Shanghai Office, Shanghai 200020 (China); Deng, Bin [Institute of Heat Transfer Technology, Golden Dragon Precise Copper Tube Group Inc., Shanghai 200135 (China)

    2010-10-15

    Condensation heat transfer characteristics of R410A-oil mixture in 5 mm and 4 mm outside diameter horizontal microfin tubes were investigated experimentally. The experimental condensing temperature is 40 C, and nominal oil concentration range is from 0% to 5%. The test results indicate that the presence of oil deteriorates the heat transfer. The deterioration effect is negligible at nominal oil concentration of 1%, and becomes obvious with the increase of nominal oil concentration. At 5% nominal oil concentration, the heat transfer coefficient of R410A-oil mixture is found to have a maximum reduction of 25.1% and 23.8% for 5 mm and 4 mm tubes, respectively. The predictabilities of the existing condensation heat transfer correlations were verified with the experimental data, and Yu and Koyama correlation shows the best predictability. By replacing the pure refrigerant properties with the mixture's properties, Yu and Koyama correlation has a deviation of -15% to + 20% in predicting the local condensation heat transfer coefficient of R410A-oil mixture. (author)

  5. REFRIGERANT/LUBRICANT MIXTURES: PROBLEMS OF APPLICATION AND PROPERTY RESEARCH

    Directory of Open Access Journals (Sweden)

    Yu. Semenyuk

    2013-10-01

    Full Text Available The results and generalizations of thermophysical property research for the refrigerant/lubricant mixtures are summarized. The methodological aspects of the experimental studies of the thermal properties of real working media for vapor compression refrigeration machines and the general principles of the thermodynamic properties simulation for such solutions are analyzed. It is shown that the admixtures of compressor oil in the refrigerant make the efficiency parameters of compressor systems much lower. The question of a selective solubility of the multicomponent refrigerants in compressor oils is discussed.

  6. Liquid viscosity of low-GWP refrigerant mixtures (R32 + R1234yf) and (R125 + R1234yf)

    International Nuclear Information System (INIS)

    Dang, Yagu; Kamiaka, Takumi; Dang, Chaobin; Hihara, Eiji

    2015-01-01

    Highlights: • We measured liquid viscosity of low GWP refrigerant R1234yf binary mixtures. • Viscosity of R1234yf mixtures were correlated with the roughness hard-sphere method. • Viscosity of R1234yf mixtures were correlated with the Grunberg and Nissan method. - Abstract: In this work, the viscosity of R1234yf, (R32 + R1234yf), and (R125 + R1234yf) in one-phase liquid was measured. The combined expanded uncertainty of viscosity measurement apparatus of confidence of 0.95 (k = 2) is about 2.0%. The measurements of mixtures containing (30.0, 50.0, and 70.0) wt% R32 or R125 were carried out between T = (283.0 and 323.0) K (at intervals of T = 5 K) and P = (1.58 and 2.74) MPa, with a moving piston viscometer (VISCOpro 1600, accuracy ±1.0%) and a Coriolis flowmeter (Ultramass MKII, accuracy ±0.001 g/ml). The measured data were correlated with a hard-sphere (RSH) method and the Grunberg and Nissan method. The average absolute deviations are (2.2 and 3.3)% for the (R32 + R1234yf) and (R125 + R1234yf) mixtures by RSH method, (2.8 and 1.3)% for the (R32 + R1234yf) and (R125 + R1234yf) mixtures by Grunberg and Nissan method, while (3.5 and 2.4)% for the (R32 + R1234yf) and (R125 + R1234yf) mixtures by RefProp V9.1, respectively

  7. Polyhalogenated hydrocarbon refrigerants and refrigerant oils colored with fluorescent dyes and method for their use as leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parekh, M.

    1988-07-19

    A leak detectable refrigeration composition is described comprising: (A) a refrigeration liquid selection from the group consisting of: (1) a polyhalogenated hydrocarbon refrigerant; (2) a refrigeration oil selected from the group consisting of naphthenic oils, paraffinic oils, alkylated benzenes, silicones, polyglycols, diesters or triesters of dicarboxylic or tricarboxylic acids, and polyalkyl silicate oils, and (3) a mixture of A(1) and A(2), and (B) a fluorescent dye compound or composition comprising the dye selected from the group consisting of: (1) a fluorescent dye selected from the group consisting of perylene, naphthoxanthene, monocyclic aromatic compounds having an organometallic compound, (2) a solution of fluorescent dye in a solvent, and (3) a mixture of B(1) and B(2). The fluorescent dye compound or composition is soluble in the refrigeration liquid. The concentration of the dye being at least 0.001 grams per 100 grams of the refrigeration liquid.

  8. Performance and energy saving analysis of a refrigerator using hydrocarbon mixture (HC-R134a) as working fluid

    Science.gov (United States)

    Mohtar, M. N.; Nasution, H.; Aziz, A. A.

    2015-12-01

    The use of hydrocarbon mixture as a working fluid in a refrigerator system is rarely explored. Almost all domestic refrigerators use hydroflourocarbon R134a (HFC-R134a) as refrigerants. In this study, hydrocarbon gas (HC-R134a) is used as the alternative refrigerant to replace HFC-R134a. It has a composition of R290 (56%), R600a (54.39%) and additive (0.1%wt) blended for the trials. The experiments were conducted with 105 g and 52.5 g refrigerant mass charge, subjected to internal heat load of 0, 1, 2, 3 and 4 kg respectively. The study investigates the coefficient of performance of the refrigerator (COPR) and energy consumption. The results show that the use of HC-R134a as the replaceable refrigerant can save energy ranging from 2.04% to 7.09%, as compared to the conventional HFC-R134a refrigerant. Naturally, the COPR improvement and temperature distribution using HC-R134a are much better than HFC-R134a

  9. Performance computation of window air conditioner with very low GWP near azeotropic refrigerant mixtures as a drop in Substitutes to R22

    Directory of Open Access Journals (Sweden)

    Vali Shaik Sharmas

    2018-01-01

    Full Text Available The principal objective of the present study is to compute the thermodynamic performance of window air conditioner based on standard vapour compression refrigeration cycle using R22, R407C and nineteen refrigerant mixtures. In this work nineteen R290/R1270 blends at different compositions are developed. A MATLAB code is developed to compute the thermodynamic performance parameters of all the studied refrigerants at condensing and evaporating temperatures of 54.4°C and 7.2°C respectively. The performance parameters are cooling effect, compressor work, COP, compressor discharge temperature, power per ton of refrigeration and volumetric cooling capacity respectively. Analytical results revealed that COP of new binary mixture R290/R1270 (90/10 by mass % is 2.82% higher among R22, R407C and nineteen studied refrigerants. Energy required by the compressor per ton of refrigeration for R290/R1270 (90/10 by mass % is 2.73% lower among R22, R407C and nineteen studied fluids. The discharge temperature of the compressor for all the nineteen investigated blends are reduced by 6.0-8.9oC compared to R22. Overall thermodynamic performance of window air conditioner with R290/R1270 (90/10 by mass % is better than R22 with significant savings in energy consumption and hence it is an energy efficient ecofriendly refrigerant mixture as a drop in substitute to R22.

  10. Analysis of a variable speed air conditioner considering the R-290/POE ISO 22 mixture effect

    International Nuclear Information System (INIS)

    Ribeiro, Guilherme B.; Barbosa, Jader R.

    2016-01-01

    Highlights: • A numerical model that considers the oil-refrigerant mixture effect is proposed. • In order to compare the model, an air conditioner calorimeter was constructed. • The system was evaluated under oil circulation ratios between 1 and 7%. • The presence of oil resulted in a significant SEER deterioration (around 69%). - Abstract: Air-conditioning applications using propane (R-290) have several environmental and thermodynamic advantages over more commonly used refrigerants, such as R-410A and R-22. This paper presents the development of a mathematical model for variable capacity air conditioning systems that use R-290/POE ISO 22 as refrigerant/lubricant. The thermodynamic performance of the refrigeration system is evaluated in terms of the SEER (Seasonal Energy Efficiency Ratio). The thermodynamic properties of the refrigerant/lubricant mixture were obtained from a departure-function approach using the Peng-Robinson equation of state. The effect of the oil on the condenser and evaporator heat transfer coefficients and pressure drops was also taken into account. Sub-models were developed for each component of the air conditioning system, including the connecting lines and the scroll compressor. Furthermore, an air conditioner experimental calorimeter was constructed and tested in order to validate the proposed model.

  11. Modified Peng-Robinson Equation of State for Pure and Mixture Refrigerants with R-32,R-125 and R-134a

    Science.gov (United States)

    Ll, Jin; Sato, Haruki; Watanabe, Koichi

    On the basis of critically-evaluated thermodynamic property data among those recently published, a new Peng-Robinson equation of state for the HFC refrigerants,R-32,R-125 and R-134a,has be end eveloped so as to represent the VLE properties in the vapor-liquid coexisting phase at temperatures 223K-323K. In accord with a challenge to correlate the binary and/or ternary interatction parameters as functions of temperature, we have also applied the present modified Peng-Robinson equation of state to the promising alternative HFC refrigerant mixtures, i.e., R-32/125,R-32/134a and R-32/125/134a systems. The developed equation of state improves significantly its effectiveness for practical engineering property calculations at refrigerantion and air-conditioning industries in comparison with conventional Peng-Robinson equation.

  12. Thermodynamic analysis on a modified ejector expansion refrigeration cycle with zeotropic mixture (R290/R600a) for freezers

    International Nuclear Information System (INIS)

    Yan, Gang; Bai, Tao; Yu, Jianlin

    2016-01-01

    This study presents a modified ejector expansion cycle with zeotropic mixtures (R290/R600a) for freezers, in which an ejector and a phase-separator are employed to enhance the cycle performance. Energetic and exergetic methods are used to theoretically investigate the system operating characteristics. In addition, comparative research among the modified cycle, conventional ejector expansion cycle and basic throttling cycle is carried out. The results demonstrate that the modified cycle exhibits higher refrigeration COP (coefficient of performance), volumetric refrigeration capacity and system exergy efficiency than conventional ejector expansion cycle and basic throttling cycle. Under the given operation conditions, the system performance improvements of the modified cycle in terms of the COP, refrigeration capacity and system exergy efficiency over the basic throttling cycle could reach about 56.0%, 4.5% and 77.7%, respectively. The performance characteristics of the proposed cycle show its potential practical advantages in freezer applications. - Highlights: • A zeotropic mixture based ejector refrigeration cycle with a separator is proposed. • Comparative research among the different cycles is carried out. • Energetic and exergetic methods are used to investigate the system performance. • The COP and system exergy efficiency are improved by 56.0% and 77.7%, respectively.

  13. Performance of refrigerating machineries with new refrigerants; Performance des machines frigorifiques avec les nouveaux refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A; Jurkowski, R [CIAT, 01 - Culoz (France)

    1998-12-31

    This paper reports on a comparative study of the thermal performances of different refrigerants like R-22, R-134a, R-404A and R-407C when used as possible substitutes for the HCFC22 refrigerant in a given refrigerating machinery equipped with compact high performance plate exchangers. Thermal performances are compared in identical operating conditions. The behaviour of the two-phase exchange coefficient is analyzed with respect to the different parameters. The composition of the mixture after one year of operation has been analyzed too and the influence of oil on the performances is studied. (J.S.)

  14. Performance of refrigerating machineries with new refrigerants; Performance des machines frigorifiques avec les nouveaux refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A.; Jurkowski, R. [CIAT, 01 - Culoz (France)

    1997-12-31

    This paper reports on a comparative study of the thermal performances of different refrigerants like R-22, R-134a, R-404A and R-407C when used as possible substitutes for the HCFC22 refrigerant in a given refrigerating machinery equipped with compact high performance plate exchangers. Thermal performances are compared in identical operating conditions. The behaviour of the two-phase exchange coefficient is analyzed with respect to the different parameters. The composition of the mixture after one year of operation has been analyzed too and the influence of oil on the performances is studied. (J.S.)

  15. Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator

    International Nuclear Information System (INIS)

    Wongwises, Somchai; Chimres, Nares

    2005-01-01

    This work presents an experimental study on the application of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator. The hydrocarbons investigated are propane (R290), butane (R600) and isobutane (R600a). A refrigerator designed to work with HFC-134a with a gross capacity of 239 l is used in the experiment. The consumed energy, compressor power and refrigerant temperature and pressure at the inlet and outlet of the compressor are recorded and analysed as well as the distributions of temperature at various positions in the refrigerator. The refrigerant mixtures used are divided into three groups: the mixture of three hydrocarbons, the mixture of two hydrocarbons and the mixture of two hydrocarbons and HFC-134a. The experiments are conducted with the refrigerants under the same no load condition at a surrounding temperature of 25 deg. C. The results show that propane/butane 60%/40% is the most appropriate alternative refrigerant to HFC-134a

  16. Relationship between composition of mixture charged and that in circulation in an auto refrigerant cascade and a J-T refrigerator operating in liquid refrigerant supply mode

    Science.gov (United States)

    Sreenivas, Bura; Nayak, H. Gurudath; Venkatarathnam, G.

    2017-01-01

    The composition of the refrigerant mixture in circulation during steady state operation of J-T and allied refrigerators is not the same as that charged due to liquid hold up in the heat exchangers and phase separators, as well as the differential solubility of different refrigerant components in the compressor lubricating oil. The performance of refrigerators/liquefiers operating on mixed refrigerant cycles is dependent on the mixture composition. It is therefore important to charge the right mixture that results in an optimum composition in circulation during steady state operation. The relationship between the charged and circulating composition has been experimentally studied in a J-T refrigerator operating in the liquid refrigerant supply (LRS) mode and an auto refrigerant cascade refrigerator (with a phase separator) operating in the gas refrigerant supply (GRS) mode. The results of the study are presented in this work. The results show that the method presented earlier for J-T refrigerators operating in GRS mode is also applicable in the case of refrigerators studied in this work.

  17. Evaporation of new refrigerants on tubes with improved surfaces; Evaporation de nouveaux refrigerants sur des tubes a surface amelioree

    Energy Technology Data Exchange (ETDEWEB)

    Kattan, N.; Favrat, D.; Thome, J. R.; Nidegger, E.; Zuercher, O. [Ecole Polytechnique Federale, Lab. d` Energetique Industrielle (LENI), Lausanne (Switzerland)

    1995-07-15

    The substitution of old refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, request a good knowledge of heat transfer properties of substitute fluids. The test measurements in LENI test facility (concentric tubes with water flowing in a counter-current flow) with new refrigerants like HFC134a, HCFC123, R-404A, R-402A, have established a new data bank with new refrigerants, a comparison with old refrigerants like CFC11, CFC12 CFC/HCFC502 and with existent correlations. Correlations were programmed to calculate and compare heat transfer coefficient during the tests. To develop a new correlation based on flow regimes, a high speed Sony video tape camera is used to observe and identify flow patterns. Important images are captured, digitalized, stored for later analysis and sent to a color plotter. Several flow pattern maps were programmed and compared to flow regimes observed on the test rig. Local flow boiling heat transfer coefficients were measured for HFC134a and HCFC123 evaporating inside a microfin tube. In addition, microfin heat transfer augmentation relative to plain tube test data was investigated. The presence of oil in the evaporator has an effect on heat transfer coefficient. Local flow boiling heat transfer coefficients were measured for refrigerant HFC134a-oil ester (Mobil EAL Arctic 68). A new thermodynamic approach for modeling mixtures of refrigerants and lubricating oils is developed. A very high accuracy, straight vibrating tube type of density flowmeter is used to measure oil concentrations of flowing HFC134a-oil mixtures. (author) 28 figs., 25 refs.

  18. Evaporation heat transfer for R-22 and R-407C refrigerant-oil mixture in a microfin tube with a U-bend

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Keumnam; Tae, Sang-Jin [Sungkyunkwan University, Suwon (D.P.R. of Korea). School of Mechanical Engineering

    2000-05-01

    Evaporation heat transfer experiments for two refrigerants, R-407C and R-22, mixed with polyol ester and mineral oils were performed in straight and U-bend sections of a microfin tube. Experimental parameters include an oil concentration varied from 0 to 5%, an inlet quality varied from 0.1 to 0.5, two mass fluxes of 219 and 400 kg m{sup -2} s{sup -1} and two heat fluxes of 10 and 20 kW m{sup -2}. Pressure drop in the test section increased by approximately 20% as the oil concentration increased from 0 to 5%. Enhancement factors decreased as oil concentration increased under inlet quality of 0.5, mass flux of 219 kg m{sup -2} s{sup -1} and heat flux of 10 kW m{sup -2}, whereas they increased under inlet quality of 0.1, mass flux of 400 kg m{sup -2} s{sup -1}, and heat flux of 20 kW m{sup -2}. The local heat transfer coefficient at the outside curvature of a U-bend was larger than that at the inside curvature of a U-bend, and the maximum value occurred at the 90{sup o} position of the U-bend. The heat transfer coefficient was larger in a region of 30 tube diameter length at the second straight section than that at the first straight section. (author)

  19. Use of nanoparticles to make mineral oil lubricants feasible for use in a residential air conditioner employing hydro-fluorocarbons refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ruixiang [School of Energy and Power Engineering, Xi' an Jiaotong University 710049 Xi' an (China); School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture, No. 1, Zhanlan Guan Road, Beijing 100044 (China); Wu, Qingping; Wu, Yezheng [School of Energy and Power Engineering, Xi' an Jiaotong University 710049 Xi' an (China)

    2010-11-15

    The application of nano-fluids in refrigerating systems is considered to be a potential way to improve the energy efficiency and reliability of HVAC and R facilities and to make economic the use of environment-friendly refrigerants. In this paper, we report a method that uses nanoparticles to enhance the energy efficiency of retrofitted residential air conditioners (RAC) employing HFCs as alternative refrigerants. The reliability and performance of RAC with nanoparticles in the working fluid have been investigated experimentally. A new mineral-based nano-refrigeration oil (MNRO), formed by blending some nanoparticles (NiFe{sub 2}O{sub 4}) into naphthene based oil B32, was employed in the RAC using R410a as refrigerant. A method showing how to disperse the NiFe{sub 2}O{sub 4} nanoparticles in the mineral oil refrigeration lubricants is presented together with an investigation of their stability. The solubilities of the new MNRO in R134a, R407C, R410a and R425a were measured. The performances of the RAC, such as the cooling/heating capacity, the power input and the energy efficiency ratio, were determined. The results indicate that the mixture of R410a/MNRO works normally in the RAC. The cooling/heating EER of the RAC increased about 6% by replacing the Polyol-Easter oil VG 32 lubricant with MNRO. (author)

  20. Abatement of CFC emissions in air conditioning and refrigerating technology. Partial project 9. Minderung von FCKW-Emissionen in der Klima- und Kaeltetechnik. Teilvorhaben 9; Bestimmung thermodynamischer Eigenschaften des Gemisches R 152a - R 134a. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    There are two ozone-neutral materials that could substitute the strongly ozone-destructive refrigerant R12, namely 1,1 difluoroethane (R152a) and 1,1,1,2 tetrafluoroethane (R134a). R152a has excellent thermodynamic and energetic properties. It is innocuous and easy to produce. Its great drawback is its inflammability due to the four hydrogen atoms per molecule. R134a is chemically inert and non-flammable, but its mixing behaviour with refrigerating oils poses problems. Idealised refrigeration processes using R134a show somewhat lower performance data than these using R128 so R134a would be expected to have a slightly greater primary energy demand. It may turn out that by using a mixture of R152a and R134a the unfavourable properties of the two components when used singly can be mutually moderated or completely neutralised, as follows. Addition of R134a neutralises the inflammability of R152a. A mixture may be expected to have more favourable thermodynamic and energetic properties than R134a alone. The foremost aim of the project was to determine by experiment the thermodynamic properties of the mixture of R152a and R134a. (orig./EF)

  1. Experimental investigation and correlation of two-phase frictional pressure drop of R410A-oil mixture flow boiling in a 5 mm microfin tube

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Guoliang; Hu, Haitao; Huang, Xiangchao [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Deng, Bin [Institute of Heat Transfer Technology, Golden Dragon Precise Copper Tube Group Inc., Shanghai 200135 (China); Gao, Yifeng [International Copper Association, Shanghai Office, Shanghai 200020 (China)

    2009-01-15

    This study presents experimental two-phase frictional data for R410A-oil mixture flow boiling in an internal spiral grooved microfin tube with outside diameter of 5 mm. Experimental parameters include the evaporation temperature of 5 C, the mass flux from 200 to 400 kg m{sup -2} s{sup -1}, the heat flux from 7.46 to 14.92 kW m{sup -2}, the inlet vapor quality from 0.1 to 0.8, and nominal oil concentration from 0 to 5%. The test results show that the frictional pressure drop of R410A initially increases with vapor quality and then decreases, presenting a local maximum in the vapor quality range between 0.7 and 0.8; the frictional pressure drop of R410A-oil mixture increases with the mass flux, the presence of oil enhances two-phase frictional pressure drop, and the effect of oil on frictional pressure drop is more evident at higher vapor qualities where the local oil concentrations are higher. The enhanced factor is always larger than unity and increases with nominal oil concentration at a given vapor quality. The range of the enhanced factor is about 1.0-2.2 at present test conditions. A new correlation to predict the local frictional pressure drop of R410A-oil mixture flow boiling inside the internal spiral grooved microfin tube is developed based on local properties of refrigerant-oil mixture, and the measured local frictional pressure drop is well correlated with the empirical equation proposed by the authors. (author)

  2. Analytical computation of thermodynamic performance parameters of actual vapour compression refrigeration system with R22, R32, R134a, R152a, R290 and R1270

    Directory of Open Access Journals (Sweden)

    Vali Shaik Sharmas

    2018-01-01

    Full Text Available The present work focuses on analytical computation of thermodynamic performance of actual vapour compression refrigeration system by using six pure refrigerants. The refrigerants are namely R22, R32, R134a, R152a, R290 and R1270 respectively. A MATLAB code is developed to compute the thermodynamic performance parameters of actual vapour compression system such as refrigeration effect, compressor work, COP, power per ton of refrigeration, compressor discharge temperature and volumetric refrigeration capacity at condensing and evaporating temperatures of 54.4oC and 7.2oC respectively. Analytical results exhibited that COP of both R32 and R134a are 15.95% and 11.71% higher among the six investigated refrigerants. However R32 and R134a cannot be replaced directly into R22 system. This is due to their higher compressor discharge temperature and poor volumetric capacity respectively. The discharge temperature of both R1270 and R290 are lower than R22 by 20-26oC. Volumetric refrigeration capacity of R1270 (3197 kJ/m3 is very close to that of volumetric capacity of R22 (3251 kJ/m3. Both R1270 and R290 shows good miscibility with R22 mineral oil. Overall R1270 would be a suitable ecofriendly refrigerant to replace R22 from the stand point of ODP, GWP, volumetric capacity, discharge temperature and miscibility with mineral oil although its COP is lower.

  3. Flow boiling of refrigerant-oil mixtures; Transferts de chaleur dans un melange constitue de fluide frigorigene et d'huile

    Energy Technology Data Exchange (ETDEWEB)

    Feidt, M

    1999-10-13

    The phase out of chlorine containing refrigerants (CFC and HCFC) has led to the introduction of new refrigerants and lubricants to the market. The interest in using HFC fluids as working fluids to replace fluids harmful to the stratospheric ozone layer. The study presents the influence of synthetic oil (POE ISO 68) on flow boiling of refrigerants R134a (pure fluid) and R410A (R32/R125 50%/50%). Local and average heat transfer coefficients and pressure drops have been measured for a smooth horizontal tube. The distribution of the heat transfer coefficient at the inner wall has been obtained from solving the inverse heat conduction problem (IHCP) and resulted in a local combination of nucleate and convective contributions to flow boiling. Local heat transfer coefficients have been averaged and displayed as a function of the vapour quality. For R134a: small amounts of oil (1% to 6%) in the liquid phase increased the heat transfer coefficient at low and intermediate vapour qualities (less than 0.60) compared to pure fluid. However a hugh reduction of the heat transfer has been observed at higher vapour qualities. For R410A : oil dramatically decreases the heat transfer coefficient compared to pure fluid. Pressure drops are also affected by small amounts of lubricant: an important increase has been noted for both fluids. Available design methods for flow boiling heat transfer coefficient (superposition, enhancement, asymptotic) badly predict the experimental results. Nevertheless a new design method accounting for flow patterns has shown good agreements. The influence of the lubricant on the heat transfer is discussed and a new proposition is made to calculate pressure drops. (author)

  4. COP improvement of refrigerator/freezers, air-conditioners, and heat pumps using nonazeotropic refrigerant mixtures

    Science.gov (United States)

    Westra, Douglas G.

    1993-01-01

    With the February, 1992 announcement by President Bush to move the deadline for outlawing CFC (chloro-fluoro-carbon) refrigerants from the year 2000 to the year 1996, the refrigeration and air-conditioning industries have been accelerating their efforts to find alternative refrigerants. Many of the alternative refrigerants being evaluated require synthetic lubricants, are less efficient, and have toxicity problems. One option to developing new, alternative refrigerants is to combine existing non-CFC refrigerants to form a nonazeotropic mixture, with the concentration optimized for the given application so that system COP (Coefficient Of Performance) may be maintained or even improved. This paper will discuss the dilemma that industry is facing regarding CFC phase-out and the problems associated with CFC alternatives presently under development. A definition of nonazeotropic mixtures will be provided, and the characteristics and COP benefits of nonazeotropic refrigerant mixtures will be explained using thermodynamic principles. Limitations and disadvantages of nonazeotropic mixtures will be discussed, and example systems using such mixtures will be reviewed.

  5. Flow boiling of refrigerant-oil mixtures; Transferts de chaleur dans un melange constitue de fluide frigorigene et d'huile

    Energy Technology Data Exchange (ETDEWEB)

    Feidt, M.

    1999-10-13

    The phase out of chlorine containing refrigerants (CFC and HCFC) has led to the introduction of new refrigerants and lubricants to the market. The interest in using HFC fluids as working fluids to replace fluids harmful to the stratospheric ozone layer. The study presents the influence of synthetic oil (POE ISO 68) on flow boiling of refrigerants R134a (pure fluid) and R410A (R32/R125 50%/50%). Local and average heat transfer coefficients and pressure drops have been measured for a smooth horizontal tube. The distribution of the heat transfer coefficient at the inner wall has been obtained from solving the inverse heat conduction problem (IHCP) and resulted in a local combination of nucleate and convective contributions to flow boiling. Local heat transfer coefficients have been averaged and displayed as a function of the vapour quality. For R134a: small amounts of oil (1% to 6%) in the liquid phase increased the heat transfer coefficient at low and intermediate vapour qualities (less than 0.60) compared to pure fluid. However a hugh reduction of the heat transfer has been observed at higher vapour qualities. For R410A : oil dramatically decreases the heat transfer coefficient compared to pure fluid. Pressure drops are also affected by small amounts of lubricant: an important increase has been noted for both fluids. Available design methods for flow boiling heat transfer coefficient (superposition, enhancement, asymptotic) badly predict the experimental results. Nevertheless a new design method accounting for flow patterns has shown good agreements. The influence of the lubricant on the heat transfer is discussed and a new proposition is made to calculate pressure drops. (author)

  6. Numerical analysis of an air condenser working with the refrigerant fluid R407C

    International Nuclear Information System (INIS)

    Aprea, Ciro; Maiorino, Angelo

    2007-01-01

    As CFC (clorofluorocarbon) and HCFC (hydrochlorofluorocarbon) refrigerants which have been used as refrigerants in a vapour compression refrigeration system were know to provide a principal cause to ozone depletion and global warming, production and use of these refrigerants have been restricted. Therefore, new alternative refrigerants should be searched for, which fit to the requirements in an air conditioner or a heat pump, and refrigerant mixtures which are composed of HFC (hydrofluorocarbon) refrigerants having zero ODP (ozone depletion potential) are now being suggested as drop-in or mid-term replacement. However also these refrigerants, as the CFC and HCFC refrigerants, present a greenhouse effect. The zeotropic mixture designated as R407C (R32/R125/R134a 23/25/52% in mass) represents a substitute of the HCFC22 for high evaporation temperature applications as the air-conditioning. Aim of the paper is a numerical-experimental analysis for an air condenser working with the non azeotropic mixture R407C in steady-state conditions. A homogeneous model for the condensing refrigerant is considered to forecast the performances of the condenser; this model is capable of predicting the distributions of the refrigerant temperature, the velocity, the void fraction, the tube wall temperature and the air temperature along the test condenser. Obviously in the refrigerant de-superheating phase the numerical analysis becomes very simple. A comparison with the measurements on an air condenser mounted in an air channel linked to a vapour compression plant is discussed. The results show that the simplified model provides a reasonable estimation of the steady-state response and that this model is useful to design purposes

  7. OPTIMAL SYSNTHESIS PROCESSES OF LOW-TEMPERATURE CONDENSATION ASSOCIATED OIL GAS PLANT REFRIGERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    O. Ostapenko

    2015-10-01

    Full Text Available Design of modern high-efficient systems is a key priority for the Energy Sector of Ukraine. The cooling technological streams of gas and oil refineries, including air coolers, water cooling and refrigeration systems for specific refrigerants are the objectives of the present study. Improvement of the refrigeration unit with refrigerant separation into fractions is mandatory in order to increase cooling capacity, lowering the boiling point of coolant and increasing the coefficient of target hydrocarbons extraction from the associated gas flow. In this paper it is shown that cooling temperature plays significant role in low-temperature condensation process. Two operation modes for refrigeration unit were proposed: permanent, in which the concentration of the refrigerant mixture does not change and dynamic, in which the concentration of refrigerant mixtures depends on the ambient temperature. Based on the analysis of exergy losses the optimal concentration of refrigerant mixtures propane/ethane for both modes of operation of the refrigeration unit has been determined. On the basis of the conducted pinch-analysis the modification of refrigeration unit with refrigerant separation into fractions was developed. Additional recuperative heat exchangers for utilization heat were added to the scheme. Several important measures to increase the mass flow rate of refrigerant through the second section of the refrigeration centrifugal compressor from 22.5 to 25 kg/s without violating the agreed operational mode of the compressor sections were implemented.

  8. Review of numerical simulation of capillary tube using refrigerant mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Valladares, O. [Centro de Investigacion en Energia de la UNAM, Morelos (Mexico)

    2004-05-01

    A detailed one-dimensional steady and transient state numerical simulation of the thermal and fluid-dynamic behaviour of capillary tube expansion devices considering metastable region and working with pure and mixed refrigerants has been developed and presented in previous works [Appl. Therm. Eng. 22 (2002) 173; Appl. Therm. Eng. 22 (2002) 379]. The discretized governing equations are coupled using an implicit step-by-step method. Due to the changes observed in the thermo-physical properties of mixtures using REFPROP v7.0 [Reference Fluid Thermodynamic and Transport Properties, NIST Standard Reference Database 23, Gaithersburg, MD 20899, USA, 2002] compared to REFPROP v5.0 [NIST Thermodynamic Properties of Refrigerants and Refrigerant Mixtures Database, Standard Reference Data Program, Gaithersburg, MD 20899, USA (February 1996)]; an extensive comparison of the numerical simulation developed with experimental data presented in the technical literature will be shown in order to demonstrate the accuracy of this detailed model. Finally, refrigerant-specific rating charts to predict in an easy way R-407C flow rates through adiabatic capillary tube are shown and used. (author)

  9. Review of numerical simulation of capillary tube using refrigerant mixtures

    International Nuclear Information System (INIS)

    Garcia-Valladares, O.

    2004-01-01

    A detailed one-dimensional steady and transient state numerical simulation of the thermal and fluid-dynamic behaviour of capillary tube expansion devices considering metastable region and working with pure and mixed refrigerants has been developed and presented in previous works [Appl. Therm. Eng. 22 (2002) 173; Appl. Therm. Eng. 22 (2002) 379]. The discretized governing equations are coupled using an implicit step-by-step method. Due to the changes observed in the thermo-physical properties of mixtures using REFPROP v7.0 [Reference Fluid Thermodynamic and Transport Properties, NIST Standard Reference Database 23, Gaithersbug, MD 20899, USA, 2002] compared to REFPROP v5.0 [NIST Thermodynamic Properties of Refrigerants and Refrigerant Mixtures Database, Standard Reference Data Program, Gaithersbug, MD 20899, USA (February 1996)]; an extensive comparison of the numerical simulation developed with experimental data presented in the technical literature will be shown in order to demonstrate the accuracy of this detailed model. Finally, refrigerant-specific rating charts to predict in an easy way R-407C flow rates through adiabatic capillary tube are shown and used

  10. Literature survey of heat transfer enhancement techniques in refrigeration applications

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, M.K.; Shome, B. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

    1994-05-01

    A survey has been performed of the technical and patent literature on enhanced heat transfer of refrigerants in pool boiling, forced convection evaporation, and condensation. Extensive bibliographies of the technical literature and patents are given. Many passive and active techniques were examined for pure refrigerants, refrigerant-oil mixtures, and refrigerant mixtures. The citations were categorized according to enhancement technique, heat transfer mode, and tube or shell side focus. The effects of the enhancement techniques relative to smooth and/or pure refrigerants were illustrated through the discussion of selected papers. Patented enhancement techniques also are discussed. Enhanced heat transfer has demonstrated significant improvements in performance in many refrigerant applications. However, refrigerant mixtures and refrigerant-oil mixtures have not been studied extensively; no research has been performed with enhanced refrigerant mixtures with oil. Most studies have been of the parametric type; there has been inadequate examination of the fundamental processes governing enhanced refrigerant heat transfer, but some modeling is being done and correlations developed. It is clear that an enhancement technique must be optimized for the refrigerant and operating condition. Fundamental processes governing the heat transfer must be examined if models for enhancement techniques are to be developed; these models could provide the method to optimize a surface. Refrigerant mixtures, with and without oil present, must be studied with enhancement devices; there is too little known to be able to estimate the effects of mixtures (particularly NARMs) with enhanced heat transfer. Other conclusions and recommendations are offered.

  11. Evaporation of new refrigerants on tube with improved surfaces. Final report. Appendices: A, B, C, D, E and F; Evaporation de nouveaux refrigerants sur des tubes a surface amelioree. Rapport final. Annexes: A, B, C, D, E et F

    Energy Technology Data Exchange (ETDEWEB)

    Kattan, N.; Favrat, D.; Thome, J. R.; Nidegger, E.; Zuercher, O. [Ecole Polytechnique Federale, Lab. d` Energetique Industrielle (LENI), Lausanne (Switzerland)

    1995-07-15

    The substitution of old refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, request a good knowledge of heat transfer properties of substitute fluids. The test measurements in LENI test facility (concentric tubes with water flowing in a counter-current flow) with new refrigerants like HFC134a, HCFC123, R-402A, have established a new data bank with new refrigerants, a comparison with old refrigerants like CFC11, CFC12 CFC/HCFC502 and with existent correlations. Correlations were programmed to calculate and compare heat transfer coefficient during the tests. To develop a new correlation based on flow regimes, a high speed Sony video tape camera is used to observe and identify flow patterns. Important images are captured, digitalized, stored for later analysis and sent to a color plotter. Several flow pattern maps were programmed and compared to flow regimes observed on the test rig. Local flow boiling heat transfer coefficients were measured for HFC134a and HCFC123 evaporating inside a microfin tube. In addition, microheat transfer augmentation relative to plain tube test data was investigated. The presence of oil in the evaporator has an effect on heat transfer coefficient. Local flow boiling heat transfer coefficients were measured for refrigerant HFC134a-oil ester (Mobil EAL Arctic 68). A new thermodynamic approach for modeling mixtures of refrigerants and lubricating oils is developed. A very high accuracy, straight vibrating tube type of density flowmeter is used to measure oil concentrations of flowing HFC134a-oil mixtures. (author) figs., tabs., refs.

  12. Substitution of the CFCs R-11, R-13, R-503, R-13B1, R-113, R-114 and R-12B1 in existing refrigerating, air-conditioning and heat pump systems with refrigerants of low ozone depletion potential in the Federal Republic of Germany. Status report; Ersatz der FCKW R11, R13, R503, R13B1, R113, R114, und R12B1 in bestehenden Kaelte-, Klima- und Waermepumpenanlagen in der Bundesrepublik Deutschland durch Kaeltemittel mit geringem Ozonabbaupotential. Statusbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    The technical basics and the state of the art for the substitution of the CFC refrigerants R-11, R-13, R-503, R-13B1, R-113, R-114 and R-12B1 in existing refrigeration systems are described and explained. The report contains an overview of the current applications of these refrigerants in the FRG, a review and discussion of existing substitutes, the presentation and evaluation of research and experiences with the conversion to alternative refrigerants, the presentation of the required infrastructure and a discussion of the technical feasibility. The conversion of existing systems to refrigerants of lower ozone depletion potential is in conclusion evaluated with regard to its technical feasibility, environmental relevance and economic efficiency. (orig.) [Deutsch] Es werden die technischen Grundlagen und der Stand der Technik zum Ersatz der FCKW-Kaeltemittel R11, R13, R503, R13B1, R113, R114 und R12B1 in bestehenden Kaelteanlagen dargestellt und erlaeutert. Der Bericht beinhaltet einen Ueberblick ueber die derzeitige Anwendung dieser Kaeltemittel in der BRD, die Vorstellung und Diskussion existierender Ersatzstoffe, die Darstellung und Bewertung der Forschung und Erfahrungen zu Umruestungen auf Ersatzstoffe, die Vorstellung der erforderlichen Infrastruktur und die Diskussion der technischen Durchfuehrbarkeit. Die Umstellung bestehender Anlagen auf Kaeltemittel mit geringerem Ozonabbaupotential wird abschliessend hinsichtlich der technischen Durchfuehrbarkeit, der Umweltrelevanz und der Wirtschaftlichkeit bewertet. (orig.)

  13. The use of an MHV-2 equation of state for modeling the thermodynamic properties of refrigerant mixtures

    International Nuclear Information System (INIS)

    Morrison, J.D.; Barley, M.H.; Parker, I.B.

    1995-01-01

    This paper reports on the development and application of a thermodynamic model based on the second-order Modified Huron Vidal equation of state (MHV-2) to predict the properties of ternary mixtures of the refrigerants R32, R125, and R134a. The mixing rules of this equation of state have been used to incorporate directly an activity-coefficient model for the excess Gibbs free energy. The parameters for the activity-coefficient model have been derived from experimental VLE data for binary mixtures. This methodology has enabled the production of a thermodynamically consistent model which can be used to predict the phase equilibria of R32/R125/R134a mixtures. The input data used in the model are presented in the paper and the predictions of the model are compared with available experimental data. The model has been used to predict the behavior of ternary refrigerant blends of R32/R125/R134a in fractionation scenarios, such as liquid charging and vapor leakage, which are of direct interest to the refrigeration industry. Details of these applications and comparisons with experimental data are discussed, along with other general uses of the thermodynamic model

  14. Test Report #33: Compressor Calorimeter Test of R-410A Alternative: R-32/R-134a Mixture Using a Scroll Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sharma, Vishaldeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-02-18

    This report investigates the tested performance of lower - GWP candidate refrigerant, 94.07 wt% R - 32 + 5.93 wt % R - 134 a mixture (hereafter referred to as R - 32/134a), as an alternative to baseline refrigerant R - 410 A using a 36,000 Btu/hr compressor calorimeter located at the Heat Exchanger Advanced Testing Facility at Oak Ridge National Laboratory . These tests were conducted during May and August 2013. R - 410A is a near - azeotropic blend of R - 32 and R - 125 with 0.5/0.5 mass fraction and has a GWP 100 of 2100. R - 32 and R - 134a are pure refrigerants and have GWP 100 of 716 and 1370 1, respectively. Based on the GWP 100 values of pure refrigerants and their mass fraction in the blend, GWP 100 of R - 32/134a, which is under development by National Refrigerant, is 755. This report compares various performance parameters, such as cooling capacity, compressor power, refrigerant mass flow rate, EER, isentropic efficiency and discharge temperature of the alternative refrigerant to that of R - 410 A.

  15. Performance of a Throttle Cycle Refrigerator with Nitrogen-Hydrocarbon and Argon-Hydrocarbon Mixtures

    Science.gov (United States)

    Venkatarathnam, G.; Senthil Kumar, P.; Srinivasa Murthy, S.

    2004-06-01

    Throttle cycle refrigerators are a class of vapor compression refrigerators that can provide refrigeration at cryogenic temperatures and operate with refrigerant mixtures. The performance of our prototype refrigerators with nitrogen-hydrocarbon, nitrogen-hydrocarbon-helium and argon-hydrocarbon refrigerant mixtures is presented in this paper.

  16. Exergetic and thermodynamic comparison of R12 and R134a as vapour compression refrigeration working fluids

    Energy Technology Data Exchange (ETDEWEB)

    De Rossi, Filippo; Mastrullo, Rita; Mazzei, Pietro [Naples Univ. (Italy)

    1993-05-01

    A software package for both the computation of thermodynamic properties and the analysis of the usual vapour compression plant schemes is a useful tool for air conditioning and refrigeration researchers and manufacturers. At present, it could make an important contribution to the search for CFC substitutes; in fact, comparisons between two or more working fluids could be accomplished more easily. A program created by the authors is presented by means of some demonstrative diagrams referring to a comparison between the ''ozone killer'' R12 and its substitute R134a. An R134a exergy-enthalpy chart is also provided. (Author)

  17. Applications of the Simple Multi-Fluid Model to Correlations of the Vapor-Liquid Equilibrium of Refrigerant Mixtures Containing Carbon Dioxide

    Science.gov (United States)

    Akasaka, Ryo

    This study presents a simple multi-fluid model for Helmholtz energy equations of state. The model contains only three parameters, whereas rigorous multi-fluid models developed for several industrially important mixtures usually have more than 10 parameters and coefficients. Therefore, the model can be applied to mixtures where experimental data is limited. Vapor-liquid equilibrium (VLE) of the following seven mixtures have been successfully correlated with the model: CO2 + difluoromethane (R-32), CO2 + trifluoromethane (R-23), CO2 + fluoromethane (R-41), CO2 + 1,1,1,2- tetrafluoroethane (R-134a), CO2 + pentafluoroethane (R-125), CO2 + 1,1-difluoroethane (R-152a), and CO2 + dimethyl ether (DME). The best currently available equations of state for the pure refrigerants were used for the correlations. For all mixtures, average deviations in calculated bubble-point pressures from experimental values are within 2%. The simple multi-fluid model will be helpful for design and simulations of heat pumps and refrigeration systems using the mixtures as working fluid.

  18. Thermodynamic analysis of an absorption refrigeration system with ionic-liquid/refrigerant mixture as a working fluid

    International Nuclear Information System (INIS)

    Kim, Yoon Jo; Kim, Sarah; Joshi, Yogendra K.; Fedorov, Andrei G.; Kohl, Paul A.

    2012-01-01

    Thermodynamics of an ionic-liquid (IL) based absorption refrigeration system has been numerically analyzed. It provides an alternative to the normally toxic working fluids, such as the ammonia in conventional absorption systems. The use of ILs also eliminates crystallization and metal-compatibility problems of the water/LiBr system. Mixtures of refrigerants and imidazolium-based ILs are theoretically explored as the working fluid pairs in a miniature absorption refrigeration system, so as to utilize waste-heat to power a refrigeration/heat pump system for electronics cooling. A non-random two-liquid (NRTL) model was built and used to predict the solubility of the mixtures. Saturation temperatures at the evaporator and condenser were set at 25 °C and 50 °C, respectively, with the power dissipation of 100 W. Water in combination with [emim][BF 4 ] (1-ethyl-3-methylimidazolium tetrafluoroborate) gave the highest coefficient of performance (COP) around 0.9. The refrigerant/IL compatibility indicated by the circulation ratio, alkyl chain length of the IL, and thermodynamic properties of the refrigerants, such as latent heat of evaporation were proven to be important factors in determining the performance of the absorption system. The negative effect of high viscosity was mitigated by dilution of the IL with the refrigerant and the use of slightly larger microfluidic channel heat exchangers. -- Highlights: ► Mixtures of refrigerant/ionic-liquid are studied for absorption system. ► We carry out comprehensive theoretical thermodynamic analysis. ► The essential factors of refrigerant/IL affecting the performance are identified. ► Water/[emim][BF 4 ] showed the best performance of COP. ► The effects of high viscosity ILs on the system performance are not significant.

  19. The effect of heat exchanger parameters on performance predictions for nonazeotropic refrigerant mixtures in liquid-liquid heat pumps

    International Nuclear Information System (INIS)

    Stanger, S.; Den Braven, K.R.; Owre, T.A.S.

    1990-01-01

    The effects of constant heat exchanger area on the coefficient of performance (COP) for liquid-liquid heat pumps were analyzed for systems which use nonazeotropic mixtures as the working fluid. For this analysis, two different computer models were compared. In the first, the log mean temperature differences (LMTDs) through the heat exchangers were specified, and were held constant for all refrigerant compositions. The second method was constructed so that the heat exchanger UA product was held constant, thus approximating constant heat exchanger area over a range of refrigerant compositions. Results from these models show only a one percent difference in COP prediction between holding LMTD constant and holding UA constant over the range of mixture composition. This paper reports the models compared using mixtures of R-22/R-11 and R-22/R-114. It is also shown that changes in glide and lift temperatures have little influence on the differences between the two models

  20. Compressor Calorimeter Test of R-410A Alternative: R-32/134a Mixture Using a Scroll Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S [ORNL; Sharma, Vishaldeep [ORNL; Abdelaziz, Omar [ORNL

    2014-02-01

    As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of lower-GWP alternative refrigerant R-32 + R-134a mixture, to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-410A and having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10 F to 55 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat, and 65 F suction temperature. A liquid subcooling level of 15 F was maintained for all the test conditions. The tests showed that the discharge temperature of the alternative refrigerant was higher than that of R-410A at all test conditions. Also, the energy efficiency ratio (EER) and cooling capacity of compressor using the alternative refrigerant were slightly lower in comparison to that of R-410A.

  1. SIMULATION OF NON-AZEOTROPIC REFRIGERANT MIXTURES FOR USE IN A DUAL-CIRCUIT REFRIGERATOR/FREEZER WITH COUNTERCURRENT HEAT EXCHANGES

    Science.gov (United States)

    The paper discusses a refrigerator/freezer (RF) system that has two complete and independent refrigeration cycles for the two compartments. It uses a non-azeotropic refrigerant mixture (NARM) in each cycle and countercurrent heat exchangers throughout. This RF is housed in a stan...

  2. Performance comparison of a refrigerator system using R134a and hydrocarbon refrigerant (HCR134a) with different expansion devices

    Science.gov (United States)

    Aziz, A.; Izzudin; Mainil, A. K.

    2017-09-01

    The objective of this study is to compare the performance of refrigerator system using working fluid between R134a refrigerant and HCR134a as hydrocarbon refrigerant for substitution of R134a. The use of capillary tube (CT) 1.5 m with HCR134a showed that slightly better COP than among the others, due to the lower pressure of condenser, conversely thermostatic expansion valve (TEV) showed that better COP than among the others with R134a. COP of CT 1.25 m and CT 1.5 m using HCR134a increase about 42.89% and 18.09% compared to R134a, where the electric current of refrigerator system decrease about 11.63% and 10.98%. However, the COP of HCR134a with CT 2.7 m and TEV were obtained lower than R134a about 16.2% and 17.06% and the use of electric current is higher than R134a about 12.98% and 16.5%. The use of HCR134a provides a higher refrigeration effect than R134a about 66.71%-88.27% for various types of expansion devices. The results confirmed that HCR134a could be an alternative refrigerant for replacement of R134a refrigerant.

  3. Phase and viscosity behaviour of refrigerant-lubricant mixtures

    DEFF Research Database (Denmark)

    Cisneros, Sergio; Garcia, J.; Fernandez, J.

    2005-01-01

    , mainly as a function of the molecular asymmetry. This also has a profound effect in the mixture transport properties. Thus, in this work the general aspects of phase and viscosity behaviour linked to the type of asymmetry found in refrigerant-lubricant mixtures are discussed in the context of phase...

  4. Heat transfer correlations for evaporation of refrigerant mixtures flowing inside horizontal microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiaoyan [School of Energy Engineering, Xi' an University of Science and Technology, 58 Yanta Street, Xi' an, Shaanxi 710054 (China); School of Energy and Power Engineering, Xi' an Jiaotong University, 28 Xianning Road, Xi' an, Shaanxi 710049 (China); Yuan, Xiuling [School of Energy and Power Engineering, Xi' an Jiaotong University, 28 Xianning Road, Xi' an, Shaanxi 710049 (China)

    2008-11-15

    Based on the experimental results of R417A flowing inside horizontal microfin tubes, the present work deals with the development of prediction methods for evaporation heat transfer of refrigerant mixtures in microfin tube. The microfin model by Thome et al. is modified by adjusting the convective heat transfer term, and the other microfin model is developed by introducing the enhancement factor into the modified-Kattan model. The comparison of the calculations by several microfin models and the experimental results reveals that the new microfin models developed at the present study are in much better agreement with the experimental results with the reducing average deviation by 30-50% than the models by Thome et al. and Cavallini et al., and are recommended for the prediction of evaporation heat transfer coefficients for non-azeotropic refrigerant mixtures inside microfin tubes. (author)

  5. Heat transfer correlations for evaporation of refrigerant mixtures flowing inside horizontal microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Xiaoyan, Zhang [School of Energy Engineering, Xi' an University of Science and Technology, 58 Yanta Street, Xi' an, Shaanxi 710054 (China); School of Energy and Power Engineering, Xi' an Jiaotong University, 28 Xianning Road, Xi' an, Shaanxi 710049 (China)], E-mail: gqzxy@sohu.com; Xiuling, Yuan [School of Energy and Power Engineering, Xi' an Jiaotong University, 28 Xianning Road, Xi' an, Shaanxi 710049 (China)

    2008-11-15

    Based on the experimental results of R417A flowing inside horizontal microfin tubes, the present work deals with the development of prediction methods for evaporation heat transfer of refrigerant mixtures in microfin tube. The microfin model by Thome et al. is modified by adjusting the convective heat transfer term, and the other microfin model is developed by introducing the enhancement factor into the modified-Kattan model. The comparison of the calculations by several microfin models and the experimental results reveals that the new microfin models developed at the present study are in much better agreement with the experimental results with the reducing average deviation by 30-50% than the models by Thome et al. and Cavallini et al., and are recommended for the prediction of evaporation heat transfer coefficients for non-azeotropic refrigerant mixtures inside microfin tubes.

  6. Heat transfer correlations for evaporation of refrigerant mixtures flowing inside horizontal microfin tubes

    International Nuclear Information System (INIS)

    Zhang Xiaoyan; Yuan Xiuling

    2008-01-01

    Based on the experimental results of R417A flowing inside horizontal microfin tubes, the present work deals with the development of prediction methods for evaporation heat transfer of refrigerant mixtures in microfin tube. The microfin model by Thome et al. is modified by adjusting the convective heat transfer term, and the other microfin model is developed by introducing the enhancement factor into the modified-Kattan model. The comparison of the calculations by several microfin models and the experimental results reveals that the new microfin models developed at the present study are in much better agreement with the experimental results with the reducing average deviation by 30-50% than the models by Thome et al. and Cavallini et al., and are recommended for the prediction of evaporation heat transfer coefficients for non-azeotropic refrigerant mixtures inside microfin tubes

  7. Correlation of refrigerant mass flow rate through adiabatic capillary tubes using mixture refrigerant carbondioxide and ethane for low temperature applications

    Science.gov (United States)

    Nasruddin, Syaka, Darwin R. B.; Alhamid, M. Idrus

    2012-06-01

    Various binary mixtures of carbon dioxide and hydrocarbons, especially propane or ethane, as alternative natural refrigerants to Chlorofluorocarbons (CFCs) or Hydro fluorocarbons (HFCs) are presented in this paper. Their environmental performance is friendly, with an ozone depletion potential (ODP) of zero and Global-warming potential (GWP) smaller than 20. The capillary tube performance for the alternative refrigerant HFC HCand mixed refrigerants have been widely studied. However, studies that discuss the performance of the capillary tube to a mixture of natural refrigerants, in particular a mixture of azeotrope carbon dioxide and ethane is still undeveloped. A method of empirical correlation to determine the mass flow rate and pipe length has an important role in the design of the capillary tube for industrial refrigeration. Based on the variables that effect the rate of mass flow of refrigerant in the capillary tube, the Buckingham Pi theorem formulated eight non-dimensional parameters to be developed into an empirical equations correlation. Furthermore, non-linear regression analysis used to determine the co-efficiency and exponent of this empirical correlation based on experimental verification of the results database.

  8. Prediction of refrigerant absorption and onset of natural convection in lubricant oil

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Jader R.; Marcelino Neto, Moises A. [Department of Mechanical Engineering, Federal University of Santa Catarina, Florianopolis, SC 88040900 (Brazil); Thoma, Stefan M. [Department of Mechanical and Process Engineering, Swiss Federal Institute of Technology, Sonneggstrasse 3, 8092 Zurich (Switzerland)

    2008-11-15

    Refrigerant absorption and mixing in lubricant oil are important in the design of refrigeration compressors and refrigeration systems. Experimental work is reported on absorption of R-134a vapour through the top interface of an initially stagnant layer of pure lubricant oil. Since the liquid refrigerant is heavier than the oil, mixing is enhanced due to natural mass convection. In the present paper, the behaviour of the liquid temperature during absorption is described based on measurements carried out in a test rig consisting of a transparent 70 mm ID, 150 mm long, vertical glass tube through which absorption can be directly observed. Transient liquid temperatures were measured at three different heights in the test section (two in the vapour, one in the liquid). The experimental work is complemented by a theoretical analysis of the critical time for the onset of mass transfer induced Rayleigh instability. The model is based on a critical mass transfer Rayleigh number criterion widely reported in the literature and takes into account the variation of physical properties in the liquid layer. The critical time for the onset of natural mass convection increases with decreasing system pressure as a result of a lower equilibrium concentration at the vapour-liquid interface. (author)

  9. Evaporation of refrigerant HFC 407C on plain tubes or at an improved surface; Evaporation du refrigerant HFC 407C sur des tubes lisses ou a surface amelioree

    Energy Technology Data Exchange (ETDEWEB)

    Zuercher, O.; Favrat, D.; Thome, J. R.; Kattan, N.; Nidegger, E. [Ecole polytechnique federale, Lab. d` energetique industrielle, Lausanne (Switzerland)

    1996-11-15

    The substitution of CFC refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, requires good methods for predicting heat transfer of substitute fluids. The measurements in the LENI test facility (concentric tubes with water flowing in a counter-current flow) with HFC 407C, HFC 134a, HCFC 123, HFC 404a and HFC/HCFC 402A provide a new data bank for new refrigerants, and allow a coherent comparison with old refrigerants CFC 11, CFC 12, CFC/HCFC 502 and with existing correlations. The existing correlations were found to be inadequate. Because of this work, an improved flow pattern map and flow boiling model were developed, which resulted in a substantial progress in the accurate predict of heat transfer in plain, horizontal tubes for refrigerants without oil. The Kattan et al. correlation was programmed to calculate and compare predicted heat transfer coefficients to the new HFC 407C test data. The flow pattern map proposed by Kattan et al. was also programmed and compared to flow regimes observed for HFC 407C. It predicted the HFC 407C flow pattern data quite accurately. The original objective of the HFC 407C measurements was the validation of the Kattan et al. correlation applied to a zeotropic refrigerant blend. Local flow boiling heat transfer coefficients were measured for HFC 407C evaporating inside a microfin and a plain tube. In addition, microfin heat transfer augmentation relative to a plain tube was investigated. The presence of oil in the evaporator had a complex effect on heat transfer coefficients. Local flow boiling heat transfer coefficients were measured for refrigerant HFC 407C ester oil mixtures (Mobil EAL Arctic 68). A new thermodynamic approach for modeling mixtures of zeotropic refrigerant blends and lubricating oils was also developed. (author) figs., tabs., 14 refs.

  10. Studies on capillary tube expansion device used in J-T refrigerators operating with nitrogen-hydrocarbon mixtures

    Science.gov (United States)

    Harish Kruthiventi, S. S.; Venkatarathnam, G.

    2017-10-01

    Capillary tube expansion devices are used extensively in small closed cycle J-T refrigerators operating with refrigerant mixtures due to its low cost and the absence of any moving parts. It is possible for J-T refrigerators operating with mixtures that the velocity of refrigerant mixture at capillary tube outlet reaches a value where it equals the speed of sound at certain conditions. The variation of the speed of sound of nitrogen-hydrocarbon mixtures used in J-T refrigerators has been studied in two phase (vapour-liquid) and three-phase (Vapour-liquid-liquid) region as a function of temperature and pressure in this work. Also the conditions under which choking occurs in practical J-T refrigerators is investigated.

  11. Refrigeration Cycle Design for Refrigerant Mixtures by Molecular Simulation

    Czech Academy of Sciences Publication Activity Database

    Smith, W.R.; Francová, Magda; Kowalski, M.; Nezbeda, Ivo

    2010-01-01

    Roč. 75, č. 4 (2010), s. 383-391 ISSN 0010-0765 R&D Projects: GA AV ČR IAA400720710 Grant - others:NSERC(CA) OGP1041 Institutional research plan: CEZ:AV0Z40720504 Keywords : refrigerants * molecular simulation s * vapor–liquid equilibrium Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.853, year: 2010

  12. Redesign 3 R Machine as a Refrigerant Waste Treatment Alternative in Environmental Rescue

    Science.gov (United States)

    Negara, I. P. S.; Arsawan, I. M.

    2018-01-01

    Cooling machine technologies really affect nowadays’ modern life, not only limited in enhancement of life quality and comfort, but it has also reached the essential things of humans’ life supporter (Arora, 2001). Cooling machine technologies have direct contribution toward environmental damage such as depletion of ozone layer and global warming through synthetic refrigerant waste and leakage (CFC and HFC) to environment. The refrigerant release to the environment is 60% of the service sector. Destructive characteristics of ozone possessed by CFC were first proposed by Rowland and Molina which were then supported by yard measurement. It is estimated that ozone layer damage occurs for about 3% every decade. The ozone layer located in the stratosphere is functioned to prevent ultraviolet-B ray from entering into earth surface. This Ultraviolet-B is suspected to be the cause of health problem for humans and disorder for plants on earth. As for the purpose of this research is to obtain a product design of refrigerant waste processing system (recovery and recycle refrigerant) as well as to acknowledge the work method (COP) of cooling machines that use CFC refrigerant (R-12) as the result of recovery and recycle compared to CFC refrigerant (R-12)/pure R134a. One method that can be used is by redesigning existing equipment namely 3R machine that cannot be used anymore thus it can be reused. This research will be conducted through modifying the existing 3R machine therefore it can be reused and be easily operated as well as doing the maintenance, after that the refrigerant as the result of recovery will be tried on a refrigeration system and a test of refrigeration system work method will be conducted by using the refrigerant recycle product which is obtained and compared with the work method of the one with pure refrigeration.The result has been achieved that the redesign product of refrigerant waste processing equipment can be reused and able to perform the recovery

  13. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Cain, J.M. (Calm (James M.), Great Falls, VA (United States))

    1993-04-30

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

  14. Functional Dependence of Thermodynamic and Thermokinetic Parameters of Refrigerants Used in Mine Air Refrigerators. Part 1 - Refrigerant R407C

    Science.gov (United States)

    Nowak, Bernard; Życzkowski, Piotr; Łuczak, Rafał

    2017-03-01

    The authors of this article dealt with the issue of modeling the thermodynamic and thermokinetic properties (parameters) of refrigerants. The knowledge of these parameters is essential to design refrigeration equipment, to perform their energy efficiency analysis, or to compare the efficiency of air refrigerators using different refrigerants. One of the refrigerants used in mine air compression refrigerators is R407C. For this refrigerant, 23 dependencies were developed, determining its thermodynamic and thermokinetic parameters in the states of saturated liquid, dry saturated vapour, superheated vapor, subcooled liquid, and in the two-phase region. The created formulas have been presented in Tables 2, 5, 8, 10 and 12, respectively. It should be noted that the scope of application of these formulas is wider than the range of changes of that refrigerant during the normal operation of mine refrigeration equipment. The article ends with the statistical verification of the developed dependencies. For this purpose, for each model correlation coefficients and coefficients of determination were calculated, as well as absolute and relative deviations between the given values from the program REFPROP 7 (Lemmon et al., 2002) and the calculated ones. The results of these calculations have been contained in Tables 14 and 15.

  15. 2014 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    2014-01-01

    The proceedings of the 2014 German refrigeration and air conditioning meeting contain contributions on the following topics: cryotechnology, fundamentals and materials for the refrigeration and heat pump technology, devices and components for the refrigeration and heat pump technology, applications of refrigeration technologies, air conditioning technology and heat pump applications, cryotechnology in biology and medicine, heat transfer and ventilation, guidelines and legal topics, refrigerant fluid - oil mixtures, control and surveillance, simulation and control, ambient air.

  16. Experimental investigation of moderately high temperature water source heat pump with non-azeotropic refrigerant mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shengjun; Wang, Huaixin; Guo, Tao [Department of Thermal Energy and Refrigeration Engineering, School of Mechanical Engineering, Tianjin University, Tianjin 300072 (China)

    2010-05-15

    Experimental investigations were carried out on non-azeotropic refrigerant mixtures, named M1A (mass fraction of 20%R152a and 80%R245fa), M1B (mass fraction of 37% R152a and 63%R245fa) and M1C (mass fraction of 50%R152a and 50%R245fa), based on a water-to-water heat pump system in the condensing temperature range of 70-90 C with a cycle temperature lift of 45 C. Performance of R245fa was tested for comparison. Unfair factors in experimental comparative evaluation research with the same apparatus were identified and corrected. Experimental cycle performance of the mixtures were tested and compared with improved experimental assessment methodology. The results show that all of the mixtures deliver higher discharge temperature, higher heating capacity, higher COP and higher {epsilon}{sub h,c} than R245fa. M1B presents the most excellent cycle performance and is recommended as working fluid for moderate/high temperature heat pump. (author)

  17. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1992-11-09

    The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

  18. Influence of special attributes of zeotropic refrigerant mixtures on design and operation of vapour compression refrigeration and heat pump systems

    International Nuclear Information System (INIS)

    Rajapaksha, Leelananda

    2007-01-01

    The use of zeotropic refrigerant mixtures introduces a number of novel issues that affect the established design and operational practices of vapour compression systems used in refrigeration, air conditioning and heat pump applications. Two attributes; composition shift and temperature glide, associated with the phase changing process of zeotropic mixtures are the primary phenomena that bring in these issues. However, relevant researches are uncovering ways how careful system designs and selection of operational parameters allow improving the energy efficiency and the capacity of vapour compression refrigeration systems. Most of these concepts exploit the presence of composition shift and temperature glide. This paper qualitatively discusses how the mixture attributes influence the established heat exchanger design practices, performance and operation of conventional vapour compression systems. How the temperature glide and composition shift can be incorporated to improve the system performance and the efficiency are also discussed

  19. Investigation of the effect of different refrigerants on performances of binary geothermal power plants

    International Nuclear Information System (INIS)

    Basaran, Anil; Ozgener, Leyla

    2013-01-01

    Highlights: • Working fluid selection plays a key role on binary cycle performance. • Selected refrigerants were analyzed in the sample cycle under the same working conditions. • Energy and exergy efficiencies of binary cycle were calculated for 8 refrigerants. - Abstract: The paper tries to review the argument of the use of working fluids for binary cycle power plants and has been dedicated to this specific argument with a more general perspective. Binary cycle that allows the production of electricity from geothermal energy sources is one of these systems. In this cycle, thermal energy obtained from geothermal sources is transferred to second working fluid. Therefore, selection of second working fluid plays a key role on the cycle performance. In this study, a sample geothermal binary power cycle was modeled and 12 refrigerants that are HFC, HC, and zoetrope refrigerant mixtures were selected as working fluid. Energy and exergy efficiencies of binary cycle were calculated for 12 refrigerants. Dry type fluids of investigated refrigerants R 236ea, R 600, R 600a, and R 227ea showed higher energy and exergy efficiencies, respectively. On the other hand, R 143a, R 415A, R 290, and R 413A that are wet fluids indicated lower energy and exergy efficiencies, respectively

  20. Performance of an auto refrigerant cascade refrigerator operating in gas refrigerant supply (GRS) mode with nitrogen-hydrocarbon and argon-hydrocarbon refrigerants

    Science.gov (United States)

    Gurudath Nayak, H.; Venkatarathnam, G.

    2009-07-01

    There is a worldwide interest in the development of auto refrigerant cascade (ARC) refrigerators operating with refrigerant mixtures. Both flammable and non-flammable refrigerant mixtures can be used in these systems. The performance of an ARC system with optimum nitrogen-hydrocarbon and argon-hydrocarbon mixtures between 90 and 160 K is presented in this paper.

  1. TRANSPORT PROPERTIES FOR REFRIGERANT MIXTURES

    Directory of Open Access Journals (Sweden)

    V. Geller

    2014-06-01

    Full Text Available A set of models to predict viscosity and thermal conductivity of refrigerant mixtures is developed. A general model for viscosity and thermal conductivity use the three contributions sum form (the dilute-gas terms, the residual terms, and the liquid terms. The corresponding states model is recommended to predict the dense gas transport properties over a range of reduced density from 0 to 2. It is shown that the RHS model provides the most reliable results for the saturated-liquid and the compressed-liquid transport properties over a range of given temperatures from 0,5 to 0,95.

  2. Pilot retrofit test of refrigerant R-134a for GDSCC

    Science.gov (United States)

    Albus, J.; Brown, B.; Dungao, M.; Spencer, G.

    1994-01-01

    NASA has issued an interim policy requiring all of its Centers to eliminate consumption (purchase) of stratospheric ozone-depleting substances, including chlorofluorocarbons (CFC's), by 1995. Also, plans must be outlined for the eventual phase out of their usage. The greatest source of CFC consumption and usage at the Goldstone Deep Space Communications Complex is refrigerant R-12, which is used in many of the facility's air-conditioning systems. A pilot retrofit test shows that retrofitting R-12 air-conditioning systems with hydrofluorocarbon R-13a would be a workable means to comply with the R-12 portion of NASA's policy. Results indicate acceptable cost levels and nearly equivalent system performance.

  3. Effect of refrigeration lubricants on the heat transfer performance in the microfin tube evaporator

    Energy Technology Data Exchange (ETDEWEB)

    Cho, K N; Tae, S J [Sung Kyun Kwan University, Seoul (Korea)

    1999-01-01

    The present study experimentally investigated the defect of refrigeration lubricant on the heat transfer performance in the straight sections and U-bend of a microfin tube evaporator by using R-22/mineral oil and R-407C/POE oil. The apparatus consisted of test section with U-bend, preheater, condenser, oil injection and sampling devices, magnetic pump, mass flow meter etc. The experimental parameters were oil concentration of 0 to 5 wt%, inlet quality of 0.1 to 0.5, mass flux of 219 and 400 kg/m{sup 2}s and heat flux of 10 and 20 kw/m{sup 2}. The effects of parameters on the heat transfer coefficients were large in the order of inlet quality, mass flux and heat flux as oil concentration got increased. As oil concentration was increased, heat transfer coefficients were continuously decreased for R-22 and increased by 3% up to the concentration of 1% and then decreased for R-407C under the condition of large inlet quality, and small mass flux and heat flux. But, the heat transfer coefficients were increased up to the opposite conditions. The variation of enhancement factors for R-407C refrigerants under the opposite conditions. The variation of enhancement factors for R-407C was under 50% of that for R-22 and the variation with respect to the positions in the test section was small. The pressure drops were increased for both R-22 and R-407C refrigerants as oil concentration was increased. The pressure drops for R-407C were smaller by the maximum of 18% than those for R-22. 12 refs., 1 tab., 14 figs.

  4. Compressor Calorimeter Test of R-404A Alternatives ARM-31a, D2Y-65, L-40, and R32 + R-134a Mixture using a Scroll Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S [ORNL; Sharma, Vishaldeep [ORNL; Abdelaziz, Omar [ORNL

    2013-08-01

    As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of four lower-GWP alternative refrigerants, ARM-31a, D2Y-65, L-40, and R-32 + R-134a mixture, to that of refrigerant R-404A (baseline) in a scroll compressor designed for medium temperature refrigeration applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-404A and having a nominal rated capacity of 23,500 Btu/hr. Tests were conducted over a suction dew point temperature range of -10 F to 35 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat, and 65 F suction temperature. A liquid subcooling level of 10 F to 15 F was maintained for all the test conditions. However, the cooling capacities reported in this study are normalized for 0 F subcooling. The tests showed that the compressor energy efficiency ratio (EER) and cooling capacity with all four alternative refrigerants tested are higher at higher saturation suction and saturation discharge temperature and lower at lower saturation suction and saturation discharge temperature, compared to that of R-404A. Discharge temperatures of all the alternative refrigerants were higher than that of R-404A at all test conditions.

  5. Experimental investigation of HFC407C/HC290/HC600a mixture in a window air conditioner

    International Nuclear Information System (INIS)

    Jabaraj, D.B.; Avinash, P.; Lal, D. Mohan; Renganarayan, S.

    2006-01-01

    HCFC22, one of the widely used refrigerants in window air conditioners must be phased out soon as per the Montreal protocol. Presently, HFC407C is considered as a potential drop in substitute for HCFC22, but retrofitting HCFC22 systems with HFC407C with polyol ester oil (POE) is a major issue as HFC407C is immiscible with mineral oil. The miscibility issue of HFC407C with mineral oil was overcome with the addition of a HC blend to it. The above technoeconomic feasibility issues to retrofit the existing HCFC22 systems with an ozone friendly refrigerant and retain the energy efficiency of the system are challenges in the air conditioning sector. In this present work, an experimental analysis has been conducted in a window air conditioner retrofitted with eco-friendly refrigerant mixtures of HFC407C/HC290/HC600a without changing the mineral oil. Its performance, as well as energy consumption, was compared with the conventional one. It is observed that the mixtures demand lengthening of the condenser in order to maintain the discharge pressure within acceptable limits. This also resulted in better heat transfer at the condenser. Therefore, in this study, the condenser tube length was increased by 19% to suit the mixtures as compared to HCFC22. Compared to HCFC22, the refrigeration capacity of the new mixture was 9.54-12.76% higher than that of HCFC22, while the actual COP was found to be 11.91-13.24% higher than that of HCFC22. The overall performance has proved that the HFC407C/HC blend refrigerant mixture could be an eco-friendly substitute to phase out HCFC22

  6. Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU

    International Nuclear Information System (INIS)

    Ganni, V.; Knudsen, P.; Arenius, D.; Casagrande, F.

    2014-01-01

    The planned approach to have a turnkey helium refrigeration system for the MSU-FRIB accelerator system, encompassing the design, fabrication, installation and commissioning of the 4.5-K refrigerator cold box(es), cold compression system, warm compression system, gas management, oil removal and utility/ancillary systems, was found to be cost prohibitive. Following JLab’s suggestion, MSU-FRIB accelerator management made a formal request to evaluate the applicability of the recently designed 12GeV JLab cryogenic system for this application. The following paper will outline the findings and the planned approach for the FRIB helium refrigeration system

  7. Prediction of performance of a jet cooling system operating with pure refrigerants or non-azeotropic mixtures. Influence de la nature des fluides, purs ou en melanges non-azeotropiques, sur les performances d'une machine de climatisation a ejecto-compresseur

    Energy Technology Data Exchange (ETDEWEB)

    Dorantes, R; Lallemand, A [Centre National de la Recherche Scientifique (CNRS), 69 Villeurbanne (France). Centre de Thermique

    1995-01-01

    This paper investigates a simple model of an ejector-compression refrigeration cycle and its applications to air conditioning. The efficiency using either classical refrigerants (R11, R22, R114), other pure refrigerants (R123, R133a, R134a, R141b, R142b, R152a, RC318) or non-azeotropic mixtures is presented. The results suggest that, for different temperatures of the heat source and the heat sink, the entrainment ratio and the system efficiency depend mainly on the fluid type and the mixture composition. An exergetic analysis shows that the major part of the exergy destruction takes place in the ejector, but that the boiler and condenser exergetic losses are significant. (author)

  8. Heat and mass transfer prediction of binary refrigerant mixtures condensing in a horizontal microfin tube

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Shigeru; Yu, Jian; Ishibashi, Akira

    1999-07-01

    In the face of the phase-out of HCFC22 for its effect on globe environment, the alternative refrigerant has been paid attention in the refrigeration and heat pump industry. In the present stage, it is found that any pure refrigerant is not a good substitute of HCFC22 for the system in use. The authors have to use binary or ternary refrigerant mixtures as the substitute to meet industrial requirement. But until now, although the heat transfer characteristics of the refrigerant mixtures can be measured in experiments and predicted in some degree, the mass transfer characteristics in condensation process, which is a main part in most systems, can not be clarified by both experimental and theoretical methods. In the present study a non-equilibrium model for condensation of binary refrigerant mixtures inside a horizontal microfin tube is proposed. In this model it is assumed that the phase equilibrium is only established at the vapor-liquid interface, while the bulk vapor and the bulk liquid are in non-equilibrium in the same cross section. The mass transfer characteristic in vapor core is obtained from the analogy between mass and momentum transfer. In the liquid layer, the mass fraction distribution is neglected, but the mass transfer coefficient is treated as infinite that can keep a finite value for the mass transfer rate in liquid phase. From the calculation results compared with the experimental ones for the condensation of HFC134a/HCFC123 and HCFC22/CFC114 mixtures, it is found that the calculated heat flux distribution along the tube axis is in good agreement with that of experiment, and the calculated values of condensing length agree well with the experimental ones. Using the present model, the local mass faction distribution, the diffusion mass transfer rate and the mass transfer characteristics in both vapor and liquid phase are demonstrated. From these results, the effect of mass transfer resistance on condensation heat transfer characteristics for binary

  9. Analysis of ammonia/water and ammonia/salt mixture absorption cycles for refrigeration purposes in fishing ships

    International Nuclear Information System (INIS)

    Táboas, Francisco; Bourouis, Mahmoud; Vallès, Manel

    2014-01-01

    In this work, the use of waste heat energy of jacket water in diesel engines of fishing ships was analysed for use as a heat source for absorption refrigeration systems. The thermodynamic simulation of an absorption refrigeration cycle with three different working fluid mixtures that use ammonia as a refrigerant was carried out. This analysis was assessed in terms of the cooling demand and cycle performance as a function of the evaporator, condenser and generator temperatures. Moreover, the need for rectifying the vapour stream leaving the generator was analysed together with the drag of the fraction of non-evaporated liquid to the absorber. The results show that the NH 3 /(LiNO 3  + H 2 O) and NH 3 /LiNO 3 fluid mixtures have higher values of COP as compared to NH 3 /H 2 O fluid mixture, the differences being more pronounced at low generation temperatures. If the activation temperature is set to 85 °C, the minimum evaporation temperatures that can be achieved are −18.8 °C for the cycle with NH 3 /LiNO 3 , −17.5 °C for the cycle with NH 3 /(LiNO 3  + H 2 O) cycle and −13.7 °C for the NH 3 /H 2 O cycle at a condensing temperature of 25 °C. Also, for the NH 3 /(LiNO 3  + H 2 O) fluid mixture, it has been demonstrated that the absorption refrigeration cycle can be operated without a distillation column and in this case the water content in the refrigerant stream entering the evaporator is less than 1.5% in weight at the operating conditions selected. - Highlights: •Ammonia absorption systems can provide refrigeration necessities for fishing ships. •Absorption refrigeration systems reduce the energy consumption of fishing ships. •The NH 3 /(LiNO 3  + H 2 O) mixture is recommended for absorption refrigeration cycles

  10. Effect-directed analysis and mixture effects of AhR-active PAHs in crude oil and coastal sediments contaminated by the Hebei Spirit oil spill

    International Nuclear Information System (INIS)

    Hong, Seongjin; Lee, Sangwoo; Choi, Kyungho; Kim, Gi Beum; Ha, Sung Yong; Kwon, Bong-Oh; Ryu, Jongseong; Yim, Un Hyuk; Shim, Won Joon; Jung, Jinho; Giesy, John P.; Khim, Jong Seong

    2015-01-01

    The major AhR-active PAHs were identified in crude oil and oil-contaminated sediments by use of effect-directed analysis. As part of the study, an enhanced potency balance analysis was conducted by establishing the novel relative potency values of (alkyl)-PAHs from the H4IIE-luc bioassay. Silica gel column fractionation of crude oil resulted in greater AhR-mediated potencies in fractions of aromatics (F2) and resins (F3), and such trend was also observed for field collected sediment samples. AhR-mediated potencies of six F2 sub-fractions from HPLC indicated that the majority of F2 responses were attributable to 3–4 ring aromatics. Target PAHs including C4-phenanthrene, C1-chrysene, and C3-chrysene in sediments explained ∼18% of the bioassay-derived TCDD-EQs, however, the unknown AhR agonists and potential mixture effects remain in question. Overall, the AhR-potency and antagonistic potential of residual oil in sediment tended to decrease over time, thus monitoring of weathering process would be key for the post management of oil-contaminated sites. - Highlights: • AhR-active PAHs in crude oil and sediments were newly determined using EDA. • Novel relative potency values of (alkyl)-PAHs for AhR activity were established. • Three to four ring PAHs were identified to be major AhR agonists in crude oil. • Parent and alkyl-PAHs explained ∼18% of the total AhR-mediated potencies of crude oil. • AhR-mediated potencies apparently decreased by the timely weathering processes. - “Major AhR agonists were identified three to four ring PAHs in crude oil and sediments determined by use of effect-directed analysis.”

  11. Theoretical analysis of a combined power and ejector refrigeration cycle using zeotropic mixture

    International Nuclear Information System (INIS)

    Yang, Xingyang; Zhao, Li; Li, Hailong; Yu, Zhixin

    2015-01-01

    Highlights: • A combined power and refrigeration cycle using zeotropic mixture is analyzed. • The cycle performances with different mixture compositions are compared. • Both exergy and parametric analysis of the combined cycle are conducted. - Abstract: A theoretical study on a combined power and ejector refrigeration cycle using zeotropic mixture isobutane/pentane is carried out. The performances of different mixture compositions are compared. An exergy analysis is conducted for the cycle. The result reveals that most exergy destruction happens in the ejector, where more than 40% exergy is lost. The heat exchange in generator causes the second largest exergy loss, larger than 28%. As the mass fraction of isobutane changes ranges from 100% to 0%, the relative exergy destruction of each component is also changing. And mixture isobutane/pentane (50/50) has the maximum exergy efficiency of 7.83%. The parametric analysis of generator temperature, condenser temperature and evaporator temperature for all the mixtures shows that, all these three thermodynamic parameters have a strong effect on the cycle performance.

  12. TESTING OF REFRIGERANT MIXTURES IN RESIDENTIAL HEAT PUMPS

    Science.gov (United States)

    The report gives results of an investigation of four possibilities for replacing Hydrochlorofluorocarbon-22 (HCFC-22) with the non-ozone-depleting new refrigerants R-407D and R-407C in residential heat pumps. The first and simplest scenario was a retrofit with no hardware modific...

  13. 2014 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte- und Klimatagung 2014. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-07-01

    The proceedings of the 2014 German refrigeration and air conditioning meeting contain contributions on the following topics: cryotechnology, fundamentals and materials for the refrigeration and heat pump technology, devices and components for the refrigeration and heat pump technology, applications of refrigeration technologies, air conditioning technology and heat pump applications, cryotechnology in biology and medicine, heat transfer and ventilation, guidelines and legal topics, refrigerant fluid - oil mixtures, control and surveillance, simulation and control, ambient air.

  14. Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

    Directory of Open Access Journals (Sweden)

    Mishra Shubham

    2016-12-01

    Full Text Available Performance assessment of ejector-expansion vapor compression refrigeration system with eco-friendly R134a alternative refrigerants (R152a, R1234yf, R600a, R600, R290, R161, R32, and propylene is presented for air-conditioning application. Ejector has been modeled by considering experimental data based correlations of component efficiencies to take care of all irreversibilities. Ejector area ratio has been optimized based on maximum coefficient of performance (COP for typical air-conditioner operating temperatures. Selected refrigerants have been compared based on area ratio, pressure lift ratio, entrainment ratio, COP, COP improvement and volumetric cooling capacity. Effects of normal boiling point and critical point on the performances have been studied as well. Using ejector as an expansion device, maximum improvement in COP is noted in R1234yf (10.1%, which reduces the COP deviation with R134a (4.5% less in basic cycle and 2.5% less in ejector cycle. Hence, R1234yf seems to be best alternative for ejector expansion system due to its mild flammability and comparable volumetric capacity and cooling COP. refrigerant R161 is superior to R134a in terms of both COP and volumetric cooling capacity, although may be restricted for low capacity application due to its flammability.

  15. Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

    Science.gov (United States)

    Mishra, Shubham; Sarkar, Jahar

    2016-12-01

    Performance assessment of ejector-expansion vapor compression refrigeration system with eco-friendly R134a alternative refrigerants (R152a, R1234yf, R600a, R600, R290, R161, R32, and propylene) is presented for air-conditioning application. Ejector has been modeled by considering experimental data based correlations of component efficiencies to take care of all irreversibilities. Ejector area ratio has been optimized based on maximum coefficient of performance (COP) for typical air-conditioner operating temperatures. Selected refrigerants have been compared based on area ratio, pressure lift ratio, entrainment ratio, COP, COP improvement and volumetric cooling capacity. Effects of normal boiling point and critical point on the performances have been studied as well. Using ejector as an expansion device, maximum improvement in COP is noted in R1234yf (10.1%), which reduces the COP deviation with R134a (4.5% less in basic cycle and 2.5% less in ejector cycle). Hence, R1234yf seems to be best alternative for ejector expansion system due to its mild flammability and comparable volumetric capacity and cooling COP. refrigerant R161 is superior to R134a in terms of both COP and volumetric cooling capacity, although may be restricted for low capacity application due to its flammability.

  16. Caracterización de los aceites de refrigeración utilizados en motocompresores herméticos que trabajan con el gas refrigerante LB-12

    Directory of Open Access Journals (Sweden)

    Celestino Oro Ortiz

    2011-03-01

    Full Text Available El objetivo de este trabajo va dirigido a conocer las principales propiedades de los aceites de refrigeración de formulaciónnacional y extranjera concebidos para los sistemas que trabajan con el refrigerante R-12 y en la actualidad se utilizancon el gas refrigerante LB-12. Se realizó un análisis de laboratorio a los aceites estudiados según las normas de laASTM para los productos derivados del petróleo. Los resultados de este trabajo son de interés para la correctaselección del aceite de refrigeración atendiendo al modelo de compresor, refrigerante utilizado y condiciones deexplotación.  The use of the hydrocarbons as refrigerants in actuality have been a great diffusion in the hermetic motocompressorsof domestic refrigerators and other, in substitution of the R-12 refrigerant which result harmful to the ozone layer. Theobjective of this research was to know the principal properties of the refrigeration oils of national and foreign formulationmarketed for the refrigeration systems that work with the refrigerant R-12 and in the nowadays are using the refrigerantgas LB-12. In this work was made laboratories analysis to the oil using the ASTM norms for the oil products. Theresults of this work are interesting for the suitable selection of the refrigeration oil it must be taken into accountmotocompressor model, refrigerant used, and exploitation conditions.

  17. Prediction of vapour-liquid and vapour-liquid-liquid equilibria of nitrogen-hydrocarbon mixtures used in J-T refrigerators

    Science.gov (United States)

    Narayanan, Vineed; Venkatarathnam, G.

    2018-03-01

    Nitrogen-hydrocarbon mixtures are widely used as refrigerants in J-T refrigerators operating with mixtures, as well as in natural gas liquefiers. The Peng-Robinson equation of state has traditionally been used to simulate the above cryogenic process. Multi parameter Helmholtz energy equations are now preferred for determining the properties of natural gas. They have, however, been used only to predict vapour-liquid equilibria, and not vapour-liquid-liquid equilibria that can occur in mixtures used in cryogenic mixed refrigerant processes. In this paper the vapour-liquid equilibrium of binary mixtures of nitrogen-methane, nitrogen-ethane, nitrogen-propane, nitrogen-isobutane and three component mixtures of nitrogen-methane-ethane and nitrogen-methane-propane have been studied with the Peng-Robinson and the Helmholtz energy equations of state of NIST REFPROP and compared with experimental data available in the literature.

  18. Petroleum Diesel Fuel and Linseed Oil Mixtures as Engine Fuels

    Science.gov (United States)

    Markov, V. A.; Kamaltdinov, V. G.; Savastenko, A. A.

    2018-01-01

    The actual problem is the use of alternative biofuels in automotive diesel engines. Insufficiently studied are the indicators of toxicity of exhaust gases of these engines operating on biofuel. The aim of the study is to identify indicators of the toxicity of exhaust gases when using of petroleum diesel fuel and linseed oil mixtures as a fuel for automotive diesel engines. Physical and chemical properties of linseed oil and its mixtures with petroleum diesel fuel are considered. Experimental researches of D-245.12C diesel are carried out on mixtures of diesel fuel and corn oil with a different composition. An opportunity of exhaust toxicity indexes improvement using these mixtures as a fuel for automobiles engine is shown.

  19. Flow boiling heat transfer coefficients at cryogenic temperatures for multi-component refrigerant mixtures of nitrogen-hydrocarbons

    Science.gov (United States)

    Ardhapurkar, P. M.; Sridharan, Arunkumar; Atrey, M. D.

    2014-01-01

    The recuperative heat exchanger governs the overall performance of the mixed refrigerant Joule-Thomson cryocooler. In these heat exchangers, the non-azeotropic refrigerant mixture of nitrogen-hydrocarbons undergoes boiling and condensation simultaneously at cryogenic temperature. Hence, the design of such heat exchanger is crucial. However, due to lack of empirical correlations to predict two-phase heat transfer coefficients of multi-component mixtures at low temperature, the design of such heat exchanger is difficult.

  20. Development of Reference Equations of State for Refrigerant Mixtures Including Hydrocarbons

    Science.gov (United States)

    Miyamoto, Hiroyuki; Watanabe, Koichi

    In recent years, most accurate equations of state for alternative refrigerants and their mixtures can easily be used via convenient software package, e.g., REFPROP. In the present paper, we described the current state-of-the-art equations of state for refrigerant mixtures including hydrocarbons as components. Throughout our discussion, the limitation of the available experimental data and the necessity of the improvement against the arbitrary fitting of recent modeling were confirmed. The enough number of reliable experimental data, especially for properties in the higher pressures and temperatures and for derived properties, should be accumulated in the near future for the development of the physically-sound theoretical background. The present review argued about the possibility of the progress for the future thermodynamic property modeling throughout the detailed discussion regarding the several types of the equations of state as well as the recent innovative measurement technique.

  1. Energy and exergy analysis of a new ejector enhanced auto-cascade refrigeration cycle

    International Nuclear Information System (INIS)

    Yan, Gang; Chen, Jiaheng; Yu, Jianlin

    2015-01-01

    Highlights: • A new ejector enhanced auto-cascade refrigeration cycle using R134a/R23 is proposed. • The performance of new and basic cycles is compared by simulation method. • The new cycle outperforms the basic cycle in both energetic and exergy aspects. • Both cycles have optimum mixture compositions to obtain optimal performance. - Abstract: A new ejector enhanced auto-cascade refrigeration cycle using R134a/R23 refrigerant mixture is proposed in this paper. In the new cycle, an ejector is used to recover part of the work that would otherwise be lost in the throttling processes. The performance comparison between the new cycle and a basic auto-cascade refrigeration cycle is carried out based on the first and second laws of thermodynamics. The simulation results show that both the coefficient of performance and exergy efficiency of the new cycle can be improved by 8.42–18.02% compared with those of the basic cycle at the same operation conditions as the ejector has achieved pressure lift ratios of 1.12–1.23. It is found that in the new cycle, the highest exergy destruction occurs in the compressor followed by the condenser, cascade condenser, expansion valve, ejector and evaporator. The effect of some main parameters on the cycle performance is further investigated. The results show that for the new cycle, the achieved performance improvement over the basic cycle is also dependent on the mixture composition and the vapor quality at the condenser outlet. The coefficient of performance improvement of the new cycle over the basic cycle degrades with increasing vapor quality. In addition, there exists an optimum mixture composition to obtain the maximum coefficient of performance for the new cycle when other operation conditions are given. The optimum mixture composition of both cycles may be fixed at about 0.5 under the given evaporating temperature.

  2. Vapor-liquid critical surface of ternary difluoromethane + pentafluoroethane + 1,1,1,2-tetrafluoroethane (R-32/125/134a) mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Higashi, Y.

    1999-09-01

    The plane of vapor-liquid criticality for ternary refrigerant mixtures of difluoromethane (R-32) + pentafluoroethane (R-125) + 1,1,1,2-tetrafluoroethane (R-134a) was determined from data on the vapor-liquid coexistence curve near the mixture critical points. The composition (mass percentage) of the mixtures studied were 23% R-32 + 25% R-125 + 52% R-134a (R-407C). 25% R-32 + 15% R-125 + 60% R-134a (R-407E), and 20% R-32 + 40% R-125 + 40% R-134a (R-407A). The critical temperature of each mixture was determined by observation of the disappearance of the meniscus. The critical density of each mixture was determined on the basis of meniscus disappearance level and the intensity of the critical opalescence. The uncertainties of the temperature, density, and composition measurements are estimated as {+-}10mK, {+-}5kg{center_dot}m{sup {minus}3}, and {+-}0.05%, respectively. In addition, predictive methods for the critical parameters of R-32/125/134a mixtures are discussed.

  3. The use of TiO2 nanoparticles to reduce refrigerator ir-reversibility

    International Nuclear Information System (INIS)

    Padmanabhan, Venkataramana Murthy V.; Palanisamy, Senthilkumar

    2012-01-01

    Highlights: ► COP of hydrocarbons mixture VCRSs increases less when compared to R134a. ► Compressor ir-reversibility of VCRSs decreases by 33% (R134a), 14% (R436A and R436B). ► Total ir-reversibility of selected VCRSs decreases. ► Exergy efficiency of R134a is exceptionally low at lower reference temperature. ► Exergy efficiency of selected VCRSs increases. - Abstract: The ir-reversibility at the process of a vapour-compression refrigeration system (VCRS) with nanoparticles in the working fluid was investigated experimentally. Mineral oil (MO) with 0.1 g L −1 TiO 2 nanoparticles mixture were used as the lubricant instead of Polyol-ester (POE) oil in the R134a, R436A (R290/R600a-56/44-wt.%) and R436B (R290/R600a-52/48-wt.%)VCRSs. The VCRS ir-reversibility at the process with the nanoparticles was investigated using second law of thermodynamics. The results indicate that R134a, R436A and R436B and MO with TiO 2 nanoparticles work normally and safely in the VCRS. The VCRSs total ir-reversibility (529, 588 and 570 W) at different process was better than the R134a, R436A and R436B and POE oil system (777, 697 and 683 W). The same tests with Al 2 O 3 nanoparticles showed that the different nanoparticles properties have little effect on the VCRS ir-reversibility. Thus, TiO 2 nanoparticles can be used in VCRS with reciprocating compressor to considerably reduce ir-reversibility at the process.

  4. Effect of evaporator temperature on vapor compression refrigeration system

    Directory of Open Access Journals (Sweden)

    Abdullah A.A.A. Al-Rashed

    2011-12-01

    Full Text Available This paper presents a comparable evaluation of R600a (isobutane, R290 (propane, R134a, R22, for R410A, and R32 an optimized finned-tube evaporator, and analyzes the evaporator effect on the system coefficient of performance (COP. Results concerning the response of a refrigeration system simulation software to an increase in the amount of oil flowing with the refrigerant are presented. It is shown that there is optima of the apparent overheat value, for which either the exchanged heat or the refrigeration coefficient of performance (COP is maximized: consequently, it is not possible to optimize both the refrigeration COP and the evaporator effect. The obtained evaporator optimization results were incorporated in a conventional analysis of the vapor compression system. For a theoretical cycle analysis without accounting for evaporator effects, the COP spread for the studied refrigerants was as high as 11.7%. For cycle simulations including evaporator effects, the COP of R290 was better than that of R22 by up to 3.5%, while the remaining refrigerants performed approximately within a 2% COP band of the R22 baseline for the two condensing temperatures considered.

  5. Condensing heat transfer characteristics of hydrocarbon refrigerants in 9.52 and 12.7 mm smooth tube

    Science.gov (United States)

    Yoon, Jung-In; Lee, Ho-Saeng; Lee, Kwang-Bae; Kim, Jae-Dol; Bansal, Pradeep

    2005-12-01

    Experimental results for heat transfer characteristic and pressure gradients of hydrocarbon (HC) refrigerants and R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have one tube diameter of 12.70 mm with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local condensing heat transfer coefficients of HC refrigerants were higher than that of R-22. The average condensing heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in HC refrigerants than R-22. Comparing the heat transfer coefficient of experimental results with that of other correlations, the presented results had a good agreement with most of the Cavallini’s correlations.

  6. Experimental investigation of a two-step transport refrigerator with R744; Experimentelle Untersuchung einer zweistufigen Trans-portkaelteanlage mit R744

    Energy Technology Data Exchange (ETDEWEB)

    Moehlenkamp, A.; Lemke, N.; Koehler, J. [TU Braunschweig (Germany). Inst. fuer Thermodynamik

    2012-07-01

    Until now, predominantly closed, single-stage refrigeration cycles are used in the transport refrigeration. Two-stage cooling circuits facilitate new circuit variations and result in a significant increase in the energy efficiency in comparison to single-stage refrigeration cycles. This is especially true for the natural refrigerant R744 (carbon dioxide). Due to the thermodynamic features in the range of transport refrigeration R744 provides an alternative to the predominantly used synthetic refrigerants R404A and R410A with an enhanced global warming potential.The authors of the contribution under consideration report on a two-stage laboratory system which enables experimental investigations of transport refrigeration and is operated with the coolant R744. This two-stage laboratory system with an internal heat exchanger on a medium-pressure level continuously supplies coldness for normal refrigeration and deep-freezing. The design of the laboratory plant is based on a reference system for motor vehicles and thus corresponds to the practical conditions. First experimental results at an ambient temperature of 30 Celsius are presented and discussed.

  7. THE RESULTS OF THE STUDY BOILING POINT OUT OZONE-SAFE REFRIGERANT R410A IN THE EVAPORATORS OF REFRIGERATING MACHINES

    Directory of Open Access Journals (Sweden)

    V. G. Bukin

    2012-01-01

    Full Text Available The results of experimental research boiling heat transfer of ozone-friendly R410A refrigerant in evaporators machines and the possibility of its use in place of the prohibited refrigerant R22.

  8. Design of refrigeration system using refrigerant R134a for macro compartment

    Science.gov (United States)

    Rani, M. F. H.; Razlan, Z. M.; Shahriman, A. B.; Yong, C. K.; Harun, A.; Hashim, M. S. M.; Faizi, M. K.; Ibrahim, I.; Kamarrudin, N. S.; Saad, M. A. M.; Zunaidi, I.; Wan, W. K.; Desa, H.

    2017-10-01

    The main objective of this study is to analyse and design an optimum cooling system for macro compartment. Current product of the refrigerator is not specified for single function and not compact in size. Hence, a refrigeration system using refrigerant R134a is aimed to provide instant cooling in a macro compartment with sizing about 150 × 150 × 250 mm. The macro compartment is purposely designed to fit a bottle or drink can, which is then cooled to a desired drinking temperature of about 8°C within a period of 1 minute. The study is not only concerned with analysing of heat load of the macro compartment containing drink can, but also focused on determining suitable heat exchanger volume for both evaporator and condenser, calculating compressor displacement value and computing suitable resistance value of the expansion valve. Method of optimization is used to obtain the best solution of the problem. Mollier diagram is necessary in the process of developing the refrigeration system. Selection of blower is made properly to allow air circulation and to increase the flow rate for higher heat transfer rate. Property data are taken precisely from thermodynamic property tables. As the main four components, namely condenser, compressor, evaporator and expansion valve are fully developed, the refrigeration system is complete.

  9. Taguchi Method for Development of Mass Flow Rate Correlation Using Hydrocarbon Refrigerant Mixture in Capillary Tube

    OpenAIRE

    Sulaimon, Shodiya; Nasution, Henry; Aziz, Azhar Abdul; Abdul-Rahman, Abdul-Halim; Darus, Amer N

    2014-01-01

    The capillary tube is an important control device used in small vapor compression refrigeration systems such as window air-conditioners, household refrigerators and freezers. This paper develops a non-dimensional correlation based on the test results of the adiabatic capillary tube for the mass flow rate through the tube using a hydrocarbon refrigerant mixture of 89.3% propane and 10.7% butane (HCM). The Taguchi method, a statistical experimental design approach, was employed. This approach e...

  10. Exergy analysis of scroll compressors working with R22, R407C, and R417A as refrigerant for HVAC system

    Directory of Open Access Journals (Sweden)

    Kalaiselvam Sivakumar

    2009-01-01

    Full Text Available The rise in crisis of power enthralls the world economically and the options for conventional and non-conventional energy resources have been searched out. No system exists in this world with 100% efficiency due to several irreversibility's. If the output obtained from the system is maximum for a given input, maximum amount of energy can be saved globally. To understand the thermodynamic losses occurring in the system and to predict the available energy that can be tapped from the system, exergy plays a major role. Experimental study on exergy in a system can pave the way to understand the complete behavior of the system exergually. Conceptually exergy studies are based on simulation, to provide a new dimension to the concept of exergy experimental validation have been promoted. The analogy of exergy analysis of three refrigerants working in scroll compressors and their exergual features are explained in this paper. The refrigerants R22, R417A, and R407C and their thermo dynamical behavior, irreversibility were experimented in an air conditioning system with three scroll compressors, interaction between the system and the refrigerant in terms of pressure drop and heat transfer, friction has been implemented for the calculation of exergy. The entire system performance on the basis of refrigerant is validated in each part of the air conditioning system. The resultant coefficient of performance of R407C is 2.41% less than R22 in a R22 designed scroll compressor with minimal exergy losses. The second law efficiency of 50 to 55% obtained in R22 has fewer rules over R407C and R417A which has 48 to 52%. The diminutive deviation of results encourages R417A refrigerant to be used as a substitute for R22. Thus the exergual prediction of performance of refrigerant and second law efficiency can identify the use of eco-friendly refrigerant in scroll compressor.

  11. Hydroprocesssing of light gas oil - rape oil mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Walendziewski, Jerzy; Stolarski, Marek; Luzny, Rafal; Klimek, Bartlomiej [Faculty of Chemistry, Wroclaw University of Technology, ul. Gdanska 7/9, 50-310 Wroclaw (Poland)

    2009-05-15

    Two series of experiments of hydroprocessing of light gas oil - rape oil mixtures were carried out. The reactor feed was composed of raw material: first series - 10 wt.% rape oil and 90 wt.% of diesel oil; second series - 20 wt.% rape oil and 80 wt.% of diesel oil. Hydroprocessing of both mixtures was performed with the same parameter sets, temperature (320, 350 and 380 C), hydrogen pressure 3 and 5 MPa, LHSV = 2 h{sup -} {sup 1} and hydrogen feed ratio of 500 Nm{sup 3}/m{sup 3}. It was stated that within limited range it is possible to control vegetable oil hydrogenolysis in the presence of light gas oil fraction (diesel oil boiling range) through the proper selection of the process parameters. Hydrogenolysis of ester bonds and hydrogenation of olefinic bonds in vegetable oils are the main reactions in the process. Basic physicochemical properties of the obtained hydroprocessed products are presented. (author)

  12. Cooling performance of R510A in domestic water purifiers

    International Nuclear Information System (INIS)

    Park, Ki Jung; Lee, Yo Han; Jung, Dong Soo

    2010-01-01

    Cooling performance of R510A is examined both numerically and experimentally in an effort to replace HFC134a in the refrigeration system of domestic water purifiers. Although the use of HFC134a is currently dominant, it is being phased out in Europe and most developed countries due to its high potential contribution to global warming. To solve this problem, cycle simulation and experimental measurements are conducted with a new refrigerant mixture of 88%RE170/12%R600a using actual domestic water purifiers. This mixture has been recently numbered and listed as R510A by ASHRAE. Test results show that, due to the small internal volume of the refrigeration system of the domestic water purifiers, system performance with R510A is greatly influenced by the amount of charge. With the optimum charge amount of 20 to 21 g, approximately 50% that of HFC134a, the energy consumption of R510A is 22.3% lower than that of HFC134a. The compressor discharge temperature of R510A is 3.7 .deg. C lower than that of HFC134a at the optimum charge. Overall, R510A, a new, long term, and environmentally safe refrigerant, is a good alternative for HFC134a. Furthermore, it requires only minor changes in the refrigeration system of the domestic water purifiers

  13. 48 CFR 52.223-12 - Refrigeration Equipment and Air Conditioners.

    Science.gov (United States)

    2010-10-01

    ... and Air Conditioners. 52.223-12 Section 52.223-12 Federal Acquisition Regulations System FEDERAL... Provisions and Clauses 52.223-12 Refrigeration Equipment and Air Conditioners. As prescribed in 23.804(b), insert the following clause: Refrigeration Equipment and Air Conditioners (MAY 1995) The Contractor shall...

  14. Performance Analysis of Joule-Thomson Cooler Supplied with Gas Mixtures

    Science.gov (United States)

    Piotrowska, A.; Chorowski, M.; Dorosz, P.

    2017-02-01

    Joule-Thomson (J-T) cryo-coolers working in closed cycles and supplied with gas mixtures are the subject of intensive research in different laboratories. The replacement of pure nitrogen by nitrogen-hydrocarbon mixtures allows to improve both thermodynamic parameters and economy of the refrigerators. It is possible to avoid high pressures in the heat exchanger and to use standard refrigeration compressor instead of gas bottles or high-pressure oil free compressor. Closed cycle and mixture filled Joule-Thomson cryogenic refrigerator providing 10-20 W of cooling power at temperature range 90-100 K has been designed and manufactured. Thermodynamic analysis including the optimization of the cryo-cooler mixture has been performed with ASPEN HYSYS software. The paper describes the design of the cryo-cooler and provides thermodynamic analysis of the system. The test results are presented and discussed.

  15. Cryogenic mixed refrigerant processes

    CERN Document Server

    Venkatarathnam, Gadhiraju

    2010-01-01

    Teaches the need for refrigerant mixtures, the type of mixtures that can be used for different refrigeration and liquefaction applications, the different processes that can be used and the methods to be adopted for choosing the components of a mixture and their concentration for different applications.

  16. Estimation of performance of a J-T refrigerators operating with nitrogen-hydrocarbon mixtures and a coiled tubes-in-tube heat exchanger

    Science.gov (United States)

    Satya Meher, R.; Venkatarathnam, G.

    2018-06-01

    The exergy efficiency of Joule-Thomson (J-T) refrigerators operating with mixtures (MRC systems) strongly depends on the choice of refrigerant mixture and the performance of the heat exchanger used. Helically coiled, multiple tubes-in-tube heat exchangers with an effectiveness of over 96% are widely used in these types of systems. All the current studies focus only on the different heat transfer correlations and the uncertainty in predicting performance of the heat exchanger alone. The main focus of this work is to estimate the uncertainty in cooling capacity when the homogenous model is used by comparing the theoretical and experimental studies. The comparisons have been extended to some two-phase models present in the literature as well. Experiments have been carried out on a J-T refrigerator at a fixed heat load of 10 W with different nitrogen-hydrocarbon mixtures in the evaporator temperature range of 100-120 K. Different heat transfer models have been used to predict the temperature profiles as well as the cooling capacity of the refrigerator. The results show that the homogenous two-phase flow model is probably the most suitable model for rating the cooling capacity of a J-T refrigerator operating with nitrogen-hydrocarbon mixtures.

  17. 21 CFR 102.37 - Mixtures of edible fat or oil and olive oil.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Mixtures of edible fat or oil and olive oil. 102... for Specific Nonstandardized Foods § 102.37 Mixtures of edible fat or oil and olive oil. The common or usual name of a mixture of edible fats and oils containing less than 100 percent and more than 0 percent...

  18. The design and development of an oil-free compressor for Spacelab Refrigerator/Freezer

    Science.gov (United States)

    Hye, A.

    1984-01-01

    Design features and test results of an oil-free compressor developed for Spacelab Mission-4 Refrigerator/Freezer are detailed. The compressor has four identical pistons activated by a common eccentric shaft, operated by a brushless dc motor at 1300 rpm. The stroke of each piston is 0.28 cm, with the piston ends connected to the shaft by means of sealed needle bearings, eliminating the ned for oil. The mass flow rates produced by the compressor are by over 100 percent higher compared to the original Amfridge unit. Test results show that the compressor can meet the Spacelab refrigerator/freezer requirements.

  19. R-32 As An Alternative To Ammonia In Industrial Refrigeration

    OpenAIRE

    Pearson, Andy

    2016-01-01

    Ammonia is recognised to be the most commonly used refrigerant in industrial systems however it is limited in some applications by its toxicity. Â R-32 has similar flammability characteristics and a similar pressure-temperature relationship, and through its use as a blend component it has become widely used and readily available. Â This paper compares and contrasts ammonia and R-32 with specific reference to industrial applications. Â The analysis includes comparison of refrigerating effect, ...

  20. FY1995 study of thermodynamic properties of HFC refrigerant mixtures for Lorentz-cycled new generation air-conditioning equipments; 1995 nendo Lorentz cycle ka shinsedai kucho kikiyo HFC kei kongo reibai no netsurikigaku seishitsu ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    A hydrochlorofluorocarbon (HCFC) refrigerant, R-22, is currently being used almost exclusively as a refrigerant for conventional air-conditioning equipments. Since HCFCs are expected to be banned shortly, it is considered a crucial issue to support R and D of the air-conditioning system Lorentz-cycled with hydrofluorocarbon (HFC) refrigerants mixtures. In the present research project, therefore, it is aimed to reveal some of the essential thermodynamic properties of HFC refrigerant mixtures systematically. On the basis of a series of achievements for the last several years by the present research coordinator and his group regarding thermodynamic properties of single-component and blended HFC refrigerants, we have conducted following three major research programs rather systematically on which no challenges have ever been reported worldwide. Throughout a series of experimental as well as analytical researches performed so as to meet the objectives mentioned above, some novel knowledge and valuable outcomes could be obtained in the present study. (1) Precise measurements of vapor-liquid equilibrium properties with simultaneous determination of densities, latent heats of vaporization, and isobaric specific heat capacities in liquid phase. (2) Analytical studies to establish thermodynamic property modeling. (3) Feasibility study of evaluating the Lorentz-cycled performance. (NEDO)

  1. Efficacy of pretreating oil palm fronds with an acid-base mixture catalyst.

    Science.gov (United States)

    Jung, Young Hoon; Park, Hyun Min; Park, Yong-Cheol; Park, Kyungmoon; Kim, Kyoung Heon

    2017-07-01

    Oil palm fronds are abundant but recalcitrant to chemical pretreatment. Herein, an acid-base mixture was applied as a catalyst to efficiently pretreat oil palm fronds. Optimized conditions for the pretreatment were a 0.1M acidic acid-base mixture and 3min ramping to 190°C and 12min holding. The oil palm fronds pretreated and washed with the acid-base mixture exhibited an enzymatic digestibility of 85% by 15 FPU Accellerase 1000/g glucan after 72h hydrolysis, which was significantly higher than the enzymatic digestibilities obtained by acid or alkali pretreatment alone. This could be attributed to the synergistic actions of the acid and base, producing an 87% glucose recovery with 100% and 40.3% removal of xylan and lignin, respectively, from the solids. Therefore, an acid-base mixture can be a feasible catalyst to deconstruct oil palm fronds for sugar production. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Composition shift in liquid-recirculation refrigerating systems: an experimental investigation for the pure fluid R134a and the mixture R32/134a

    Energy Technology Data Exchange (ETDEWEB)

    Giuliani, G.; Marchesi Donati, F.; Polonara, F. [Ancona Univ. (Italy). Dip. di Energetica; Hewitt, N.J. [University of Ulster at Coleraine, Northern Ireland (United Kingdom). NICERT

    1999-09-01

    The ability of zeotropic mixtures with a remarkable temperature glide to operate in liquid-recirculation systems is investigated and the results of an experimental comparison between the performances of the pure fluid R134a and the zeotropic mixture R32/134a (25/75% by mass) are presented. R134a performs slightly better in the liquid-recirculation mode than in the traditional dry-expansion mode; on the other hand, liquid-recirculation configuration has a detrimental effect on the zeotropic mixture's performance. The reason for this detrimental effect is the mixture component separation which occurs at the liquid/vapor separator. The effect of this separation is investigated using gas chromatograph analysis.

  3. Fermilab satellite refrigerator compressors with the oil- and moisture-removal systems

    International Nuclear Information System (INIS)

    Satti, J.A.; Andrews, R.A.

    1983-08-01

    We have designed and tested a helium purification system for the Energy Doubler and the experimental areas. A purification system is installed after each screw compressor in the satellite refrigerators. The purification system removes oil mist, oil vapor, water vapor, and particulate from the compressed helium. The units were designed with consideration of modularity and necessary redundancy (i.e., guard purification). Test results which led to the final configuration are presented, along with achieved performance of the oil removal in the operating system

  4. Experimental evaluation of R448A as R404A lower-GWP alternative in refrigeration systems

    International Nuclear Information System (INIS)

    Mota-Babiloni, Adrián; Navarro-Esbrí, Joaquín; Peris, Bernardo; Molés, Francisco; Verdú, Gumersindo

    2015-01-01

    Highlights: • R448A (GWP = 1273) is an A1 refrigerant proposed in DX supermarket refrigeration systems. • Performance of R448A and R404A is evaluated under different conditions. • R448A presents lower cooling capacity but higher COP than R404A. • The R448A maximum discharge temperature is always below 380 K. • R448A is more interesting at high condensing (ambient) temperatures. - Abstract: Due to the adoption of EU Regulation No 517/2014, R404A is going to be banned in Europe in most of refrigeration applications, in which is typically used, due to its very high GWP value, 3943. In this paper an experimental comparison between R404A and R448A, a non-flammable alternative with GWP of 1390, is presented. The experimental tests are intended to simulate typical freezing and conservation temperatures and different condensing conditions. Despite cooling capacity of R448A is slightly below that of R404A, R448A energy consumption is even smaller; and R448A COP is higher than that obtained using R404A. Hence, it can be concluded that R448A could be an energy efficient alternative to R404A with a GWP reduction of 70%. Compressor discharge temperature remains at non-dangerous levels.

  5. Thermodynamic and heat transfer analyses for R1234yf and R1234ze(E) as drop-in replacements for R134a in a small power refrigerating system

    International Nuclear Information System (INIS)

    Janković, Zvonimir; Sieres Atienza, Jaime; Martínez Suárez, José Antonio

    2015-01-01

    In this paper we present two different analyses of R1234yf and R1234ze(E) as drop-in replacements for R134a in a small power refrigeration system. The first analysis is based on equal evaporation and condensation temperatures before and after the refrigerant replacement. The second analysis is carried out for equal cooling medium conditions in the condenser, so that the transport properties and the heat transfer features in the condenser are considered for the three refrigerants. In order to perform the analyses, a simulation model was developed, that takes into account specific data, characteristics and dimensions of the main components of a small power refrigeration system. The model was validated with experimental data for R134a and later used to predict the behavior with R1234yf and R1234ze(E). Results show that different conclusions may be drawn if the drop-in analysis is carried out for equal condensation temperatures or for equal temperatures of the cooling medium in the condenser, as well as that these results are affected by the condenser design. In general, R1234yf seems as an adequate drop-in refrigerant for R134a, but R1234ze(E) may perform better when an overridden compressor can be used to match the refrigerating system cooling power. - Highlights: • Low GWP refrigerants R1234yf and R1234ze(E) are potential replacements for R134a. • Refrigerating system mathematical model to predict drop-in performance. • Drop-in analysis for the same evaporation and condensation temperatures. • Drop-in analysis for the same cooling medium temperatures. • Refrigerant heat transfer features have a great impact on the drop-in performance

  6. Experimental evaluation of desuperheating and oil cooling process through liquid injection in two-staged ammonia refrigeration systems with screw compressors

    International Nuclear Information System (INIS)

    Zlatanović, Ivan; Rudonja, Nedžad

    2012-01-01

    This paper examines the problem of achieving desuperheating through liquid injection in two-staged refrigeration systems based on screw compressors. The oil cooling process by refrigerant injection is also included. The basic thermodynamic principles of desuperheating and compressor cooling as well as short comparison with traditional method with a thermosyphon system have also been presented. Finally, the collected data referring to a big refrigeration plant are analyzed in the paper. Specific ammonia system concept applied in this refrigeration plant has demonstrated its advantages and disadvantages. - Highlights: ► An experiment was setup during a frozen food factory refrigeration system reconstruction and adaptation. ► Desuperheating and low-stage compressors oil cooling process were investigated. ► Efficiency of compression process and high-stage compressors functioning were examined. ► Evaporation temperature reduction has great influence on the need for injected liquid refrigerant. ► Several cases in which desuperheating and oil cooling process application are justified were determined.

  7. Flow Boiling of Pure and Oil Contaminated Carbon Dioxide as Refrigerant

    DEFF Research Database (Denmark)

    Mohamed, A.-R. Mohamed

    2003-01-01

    of benefit of the environment. The main challenge for CO2 based refrigerant systems is to increase the performance of the heat exchangers. Especially there is a need for information concerning heat transfer and pressure drop in evaporator and condenser with CO2 as refrigerant. The reason this is the very...... to 40 kW/m2 and evaporation temperature from -10°C to -35°C corresponding to a reduced pressure between0.35 and .16. The conclusion from the measurements is that oil gives a reduction in heat transfer coefficient compared to pure CO2. The reduction in heat transfer coefficient is greater at high...... described in the present report is measured heat transfer coefficient and pressure drop for flow boiling of oil free and oil contaminated CO2. Measurements have been done on tube with internal diameter of 10 mm and 4 mm- The mass flux has been varied from 90 kg/m2s to 750 kg/m2s, heat flux from 5 kW/m2...

  8. Optimization of a cascade refrigeration system using refrigerant C_3H_8 in high temperature circuits (HTC) and a mixture of C_2H_6/CO_2 in low temperature circuits (LTC)

    International Nuclear Information System (INIS)

    Nasruddin; Sholahudin, S.; Giannetti, N.; Arnas

    2016-01-01

    Highlights: • Multi-objective optimization is conducted in the cascade refrigeration system. • Combination of operating temperature and refrigerant performance has been studied. • Characteristic of C_3H_8 and a mixture of C_2H_6/CO_2 have been investigated. • Determining of CO_2 fraction to optimize refrigeration system has been done. - Abstract: This paper discusses the multi-objectives optimization of a cascade refrigeration system using refrigerant C_3H_8 in high temperature circuits (HTC) and a mixture of C_2H_6/CO_2 in low temperature circuits (LTC). The evaporator temperature, condenser temperature, C_2H_6/CO_2 mixture condensation temperature, cascade temperature differences, and the CO_2 mass fraction are chosen as the decision variables. Whereas cooling capacity, cold space temperature, and ambient temperature are taken as the constraints. The purpose of this research is to design a cascade refrigeration system whose optimum performance are defined in terms of economics and thermodynamics. Accordingly, there are two objective functions that should be simultaneously optimized including the total annual cost which consists of the capital and operational cost and the total exergy destruction of the system. To this aim, the optimum operating temperature of the system and CO_2 fraction should be determined so that the system has minimum exergy destruction and annual cost. Results show that, the optimum value of the decision variables for this system can be determined by trade-off between annual cost and exergy destruction.

  9. Yield and characteristics of shale oil from the retorting of oil shale and fine oil-shale ash mixtures

    International Nuclear Information System (INIS)

    Niu, Mengting; Wang, Sha; Han, Xiangxin; Jiang, Xiumin

    2013-01-01

    Highlights: • The whole formation process of shale oil might be divided into four stages. • Higher ash/shale mass ratio intensified the cracking and coking of shale oil. • Ash/shale ratio of 1:2 was recommended for oil shale fluidized bed retort with fine oil-shale ash as solid heat carrier. - Abstract: For exploring and optimizing the oil shale fluidized bed retort with fine oil-shale ash as a solid heat carrier, retorting experiments of oil shale and fine oil-shale ash mixtures were conducted in a lab-scale retorting reactor to investigate the effects of fine oil-shale ash on shale oil. Oil shale samples were obtained from Dachengzi Mine, China, and mixed with fine oil-shale ash in the ash/shale mass ratios of 0:1, 1:4, 1:2, 1:1, 2:1 and 4:1. The experimental retorting temperature was enhanced from room temperature to 520 °C and the average heating rate was 12 °C min −1 . It was found that, with the increase of the oil-shale ash fraction, the shale oil yield first increased and then decreased obviously, whereas the gas yield appeared conversely. Shale oil was analyzed for the elemental analysis, presenting its atomic H/C ratio of 1.78–1.87. Further, extraction and simulated distillation of shale oil were also conducted to explore the quality of shale oil. As a result, the ash/shale mixing mass ratio of 1:2 was recommended only for the consideration of increasing the yield and quality of shale oil

  10. Low Global Warming Potential Refrigerants for Commercial Refrigeration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sharma, Vishaldeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Environmental concerns are driving regulations for the heating, ventilating, air-conditioning and refrigeration (HVAC&R) industry towards lower GWP alternatives to HFC refrigerants. Existing lower GWP refrigerant alternatives include hydrocarbons, such as propane (R-290) and isobutane (R-600a), as well as carbon dioxide (R-744), ammonia (R-717), and R-32. In addition, new lower GWP refrigerant alternatives are currently being developed by refrigerant manufacturers, including hydrofluoro-olefin (HFO) and unsaturated hydrochlorofluorocarbon (HCFO) refrigerants. The selection of an appropriate refrigerant for a given refrigeration application should be based on several factors, including the GWP of the refrigerant, the energy consumption of the refrigeration system over its operating lifetime, and leakage of refrigerant over the system lifetime. For example, focusing on energy efficiency alone may overlook the significant environmental impact of refrigerant leakage; while focusing on GWP alone might result in lower efficiency systems that result in higher indirect impact over the equipment lifetime. Thus, the objective of this Collaborative Research and Development Agreement (CRADA) between

  11. ARTI Refrigerant Database. [Quarterly progress report, 1 July 1993--30 September 1993

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1993-11-28

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R134a, R-141b, R-142b, R-143a, R-152a, R-227ea, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyol ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  12. Clathrate hydrate dissociation conditions of refrigerants R404A, R406A, R408A and R427A: Experimental measurements and thermodynamic modeling

    International Nuclear Information System (INIS)

    Hashemi, Hamed; Babaee, Saeedeh; Mohammadi, Amir H.; Naidoo, Paramespri; Ramjugernath, Deresh

    2015-01-01

    Highlights: • The application of refrigerant hydrates in cold storage systems is investigated. • Hydrate dissociation conditions of various refrigerants have been measured. • A correlative thermodynamic model was applied to the data. • Enthalpy of dissociation for the refrigerants studied calculated. • Experimental measurements performed over a wide range of pressures. - Abstract: Clathrate hydrate dissociation conditions were measured for four “alternative” refrigerants, viz. R404A, R406A, R408A and R427A. The experimental measurements were performed within the pressure range of (0.079 to 9.995) MPa and temperatures ranging from (272.7 to 288.7) K. An isochoric pressure-search method was used to perform the measurements. A thermodynamic model based on the van der Waals–Platteeuw (vdW–P) model was applied for the prediction of the dissociation conditions which were compared to the experimental measurements. The fluid phase was modeled using the MHV2 G E -EoS mixing rule along with the UNIFAC (original) activity model. The van der Waals–Platteeuw (vdW–P) model was used for the modeling of the hydrate phase. There was reasonable agreement between the experimental and predicted values

  13. ANALISIS PERBANDINGAN EVAPORATOR KULKAS (LEMARI ES DENGAN MENGUNAKAN REFRIGERANT R-22 DAN R-134A

    Directory of Open Access Journals (Sweden)

    Imam Faozan

    2017-03-01

    Full Text Available Tulisan ini bertujuan untuk mengetahui komponen mesin refrigerasi khususnya pembahasan evaporator. Dalam penelitian ini digunakan lemari pendingin (kulkas sederhana untuk pengawetan dan pendinginan bahan makanan dalam rumah tangga. Untuk refrigerant yang digunakan adalah Refrigerant Freon  R – 22 dan  Freon R - 134a sebagai perbandingan dan untuk mengetahui performance evaporator ( COP pada mesin refrigerasi untuk rumah tangga. Lemari pendingin yang dianalisa berukuran tinggi  = 1 m, panjang  = 0,55 m  dan lebar 0,5 m. Temperatur evaporasi = -5°C dan temperature kondensasi = 40°C.

  14. INTENSIFICATION OF MICROBIAL EXOPOLYSACCHARIDE ETHAPOLAN BIOSYNTHESIS ON MIXTURE OF MOLASSES AND SUNFLOWER OIL

    Directory of Open Access Journals (Sweden)

    T. P. Pirog

    2017-12-01

    Full Text Available The purpose of the research was to establish Acinetobacter sp. IMB B-7005 cultivation conditions, which provide the maximal synthesis of microbial exopolysaccharide ethapolan on a mixture of molasses and sunflower oil, and to explore the possibility of replacing refined oil in a mixture with molasses for waste one. On the basis of theoretical calculations of energy consumption for the synthesis of ethapolan and biomass, it was determined that the optimal molar ratio of the concentrations of energy-deficient (sucrose and energy-excessive (sunflower oil substrates in the mixture was 1.0:0.9. Experiments have shown that the highest values of exopolysaccharide synthesis were observed at a molar ratio of monosubstrates in mixture 1.0:1.1, which is as close as possible to the theoretically calculated one. It was shown that increasing concentration of molasses and refined oil in mixture from 1.0 to 1.5% was accompanied by increase in amount of synthesized exopolysaccharide and its synthesizing capacity by 1.2 and 1.3 times, respectively. The possibility of replacing refined oil in a mixture with molasses for various types of waste (after frying potatoes, meat, vegetables and mixed was established. The maximum parameters of exopolysaccharide synthesis (concentration 14 g/l, synthesizing capacity 3.5 g exopolysaccharide/g biomass were observed when using mixed waste oil for both inoculum obtaining and EPS biosynthesis. The obtained results testify to the possibility of development of universal technology for obtaining microbal exopolysaccharide ethapolan on a mixture of waste (molasses and waste oil independent of the type and provider of waste oil.

  15. In-tube flow boiling of R-407C and R-407C/oil mixtures. Part 1: Microfin tube

    Energy Technology Data Exchange (ETDEWEB)

    Zuercher, O; Thome, J R; Favrat, D

    1999-07-01

    In-tube evaporation tests for R-407C and R-407C/oil are reported for a microfin tube. The tests were run at a nominal inlet pressure of 645 kPa (93.5 psia) at mass velocities of 100, 200 and 300 kg/(m{sup 2}{center{underscore}dot}s) (20.5, 41, and 61 lb/s{center{underscore}dot}ft{sup 2}) over nearly the entire vapor quality range. At similar operating conditions, pure R-407C performed similarly to previous pure R-134a tests at the highest mass velocity, but lower than R-134a for the other mass velocities. Any amount of oil tended to decrease local R-407C microfin heat transfer coefficients, especially at high vapor qualities were degradations of as much as 50% or more occurred. Two-phase pressure drops were increased by the presence of oil, especially at high vapor qualities. Buildup of the local oil mass fraction in the microfin test sections was observed at high vapor qualities, together with the formation of slowly flowing viscous liquid films, a phenomenon that became more acute at lower mass velocities.

  16. Estimation of Freezing Point of Hydrocarbon and Hydrofluorocarbon Mixtures for Mixed Refrigerant jt Cryocooler

    Science.gov (United States)

    Hwang, G.; Lee, J.; Jeong, S.

    2010-04-01

    Estimating the freezing point of refrigerant is an essential part in designing an MR JT (Mixed refrigerant Joule-Thomson) cryocooler to prevent itself from clogging and to operate with stability. There were researches on estimating freezing point, but some of them resulted in the wrong prediction of clogging. In this paper, the freezing point of the MR is precisely estimated with caution of clogging. The solubility of HC (hydrocarbon) and HFC (hydrofluorocarbon) mixture components are obtained with their activity coefficients, which represent the molecular interaction among the components. The freezing points of the MR JT cryocooler are systematically investigated in the operating temperature range from 70 K to 90 K.

  17. Impact of Refrigerated Storage on Quality of Oil from Freshwater Jarko (Wallago attu Fish.

    Directory of Open Access Journals (Sweden)

    Nusrat N. Memon

    2010-12-01

    Full Text Available The effect of refrigerated storage on the quality of freshwater fish oil Jarko (Wallago attu was evaluated by measuring fatty acid profile, free fatty acids (FFA, peroxide value (PV, acid value (AV, sponification value (SV, iodine value (IV and poylene index (PI up to the time period of 120 days. After 120 days storage, mono unsaturated fatty acids (MUFA and polyunsaturated fatty acids (PUFA contents were decreased by 24.89% and 33.70%, respectively. While, saturated fatty acids (SFA content was found to be increased by 26.82%, against the actual value. The change in polyunsaturated fatty acids during refrigerated storage was measured by the PI value. The PI decreased during storage due to lipid oxidation, but remained nearly constant after 90th day of storage. The results of PV, AV and FFA demonstrates that Wallago attu fish oil remained acceptable for consumption for 60 days but eventually exceeded the recommended values after 60 days of refrigerated storage.

  18. Experimental investigation of hydrocarbon mixtures to replace HFC-134a in an automotive air conditioning system

    International Nuclear Information System (INIS)

    Wongwises, Somchai; Kamboon, Amnouy; Orachon, Banchob

    2006-01-01

    This paper presents an experimental study on the application of hydrocarbon mixtures to replace HFC-134a in automotive air conditioners. The hydrocarbons investigated are propane (R290), butane (R600) and isobutane (R600a). The measured data are obtained from an automotive air conditioning test facility utilizing HFC-134a as the refrigerant. The air conditioner, with a capacity of 3.5 kW driven by a Diesel engine, is charged and tested with four different ratios of hydrocarbon mixtures. The experiments are conducted at the same surrounding conditions. The temperature and pressure of the refrigerant at every major position in the refrigerant loop, the temperature, flow rate and humidity of air, torque and engine speed are recorded and analyzed. The parameters investigated are the refrigeration capacity, the compressor power and the coefficient of performance (COP). The results show that propane/butane/isobutane: 50%/40%/10% is the most appropriate alternative refrigerant to replace HFC-134a, having the best performance of all the hydrocarbon mixtures investigated

  19. Impact of the lubricating oil on thermodynamic performances of reversible heat pumps; Impact de l'huile de lubrification sur les performances thermodynamiques des pompes a chaleur reversibles

    Energy Technology Data Exchange (ETDEWEB)

    Youbi-Idrissi, M

    2003-12-01

    This work deals with the effect of oil on the energy performances of refrigerating systems. To characterise this impact, two thermodynamic properties were studied: the solubility and the enthalpy. Thus, a simple measurement method was presented, allowing to study both transient and steady-state behaviour of various refrigerant/oil pairs. Thus, experimental data were validated and modelled. The suitable use of the solubility curves showed the zeotropic character of the refrigerant/oil mixture, which is directly reflected on the enthalpy calculation. For this property, a thermodynamic model was developed and experimentally validated. Its application led to a new presentation of the Mollier diagram taking into account the oil presence. It was then shown that, among all the circuit elements, the evaporator is the most penalized by the oil presence. Its performances decrease when the circulating mass fraction of oil increases, the superheat decreases and when the refrigerant-oil solubility increases. An experimental study on a reversible heat pump confirmed that if the circulation mass fraction of oil in the machine is lower than 2%, the impact of oil is reduced. Lastly, a local model of a refrigerating unit, initially charged with a zeotropic mixture, allowed to analyse the profiles of temperature, heat transfer coefficient and local composition of the refrigerant along a circuit. (author)

  20. Condensation of pure and near-azeotropic refrigerants in microfin tubes: A new computational procedure

    Energy Technology Data Exchange (ETDEWEB)

    Cavallini, A; Del Col, D; Mancin, S; Rossetto, L [Dipartimento di Fisica Tecnica, University of Padova, Via Venezia 1, Padova 35131 (Italy)

    2009-01-15

    Microfin tubes are widely used in air cooled and water cooled heat exchangers for heat pump and refrigeration applications during condensation or evaporation of refrigerants. In order to design heat exchangers and to optimize heat transfer surfaces, accurate procedures for computing pressure drops and heat transfer coefficients are necessary. This paper presents a new simple model for the prediction of the heat transfer coefficient to be applied to condensation in horizontal microfin tubes of halogenated and natural refrigerants, pure fluids or nearly azeotropic mixtures. The updated model accounts for refrigerant physical properties, two-phase flow patterns in microfin tubes and geometrical characteristics of the tubes. It is validated against a data bank of 3115 experimental heat transfer coefficients measured in different independent laboratories all over the world including diverse inside tube geometries and different condensing refrigerants among which R22, R134a, R123, R410A and CO{sub 2}. (author)

  1. Greenhouse gas emissions for refrigerant choices in room air conditioner units.

    Science.gov (United States)

    Galka, Michael D; Lownsbury, James M; Blowers, Paul

    2012-12-04

    In this work, potential replacement refrigerants for window-mounted room air conditioners (RACs) in the U.S. have been evaluated using a greenhouse gas (GHG) emissions analysis. CO(2)-equivalent emissions for several hydrofluoroethers (HFEs) and other potential replacements were compared to the most widely used refrigerants today. Included in this comparison are pure refrigerants that make up a number of hydrofluorocarbon (HFC) mixtures, pure hydrocarbons, and historically used refrigerants such as propane and ammonia. GHG emissions from direct and indirect sources were considered in this thermodynamic analysis. Propylene, dimethyl ether, ammonia, R-152a, propane, and HFE-152a all performed effectively in a 1 ton window unit and produced slightly lower emissions than the currently used R-22 and R-134a. The results suggest that regulation of HFCs in this application would have some effect on reducing emissions since end-of-life emissions remain at 55% of total refrigerant charge despite EPA regulations that mandate 80% recovery. Even so, offsite emissions due to energy generation dominate over direct GHG emissions and all the refrigerants perform similarly in totals of indirect GHG emissions.

  2. Impact of the lubricating oil on thermodynamic performances of reversible heat pumps; Impact de l'huile de lubrification sur les performances thermodynamiques des pompes a chaleur reversibles

    Energy Technology Data Exchange (ETDEWEB)

    Youbi-Idrissi, M.

    2003-12-01

    This work deals with the effect of oil on the energy performances of refrigerating systems. To characterise this impact, two thermodynamic properties were studied: the solubility and the enthalpy. Thus, a simple measurement method was presented, allowing to study both transient and steady-state behaviour of various refrigerant/oil pairs. Thus, experimental data were validated and modelled. The suitable use of the solubility curves showed the zeotropic character of the refrigerant/oil mixture, which is directly reflected on the enthalpy calculation. For this property, a thermodynamic model was developed and experimentally validated. Its application led to a new presentation of the Mollier diagram taking into account the oil presence. It was then shown that, among all the circuit elements, the evaporator is the most penalized by the oil presence. Its performances decrease when the circulating mass fraction of oil increases, the superheat decreases and when the refrigerant-oil solubility increases. An experimental study on a reversible heat pump confirmed that if the circulation mass fraction of oil in the machine is lower than 2%, the impact of oil is reduced. Lastly, a local model of a refrigerating unit, initially charged with a zeotropic mixture, allowed to analyse the profiles of temperature, heat transfer coefficient and local composition of the refrigerant along a circuit. (author)

  3. Combustion of soybean oil and diesel mixtures for heating purposes

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Adriana Correa; Sanz, Jose Francisco [European University Miguel de Cervantes, Valladolid (Spain)], E-mail: acorrea@uemc.es; Hernandez, Salvador; Navas, Luis Manuel; Rodriguez, Elena; Ruiz, Gonzalo [University of Valladolid (Spain). Dept. of Agricultural and Forest Engineering; San Jose, Julio [University of Valladolid (Spain). Dept. of Energetic Engineering; Gomez, Jaime [University of Valladolid (Spain). Dept. of Communications and Signal Theory and Telematics Engineering

    2008-07-01

    Using blends of vegetable oils with petroleum derivates for heating purposes has several advantages over other energy application for vegetable oils. This paper presents the results of an investigation by use of soybean oil and diesel mixture as fuel for producing heat in conventional diesel installation. The paper is set out as follows: properties characterization of soybean oil as fuel and of diesel oil, as well as the mixture of both; selection of the mixture according to their physical chemical properties and how they adapt to conventional combustion installation; experimentation with the selected mixture, allowing the main combustion parameters to be measured; processing the collected data, values of combustion, efficiency and reduction of emissions. Conclusions show that the use of soybean oil and diesel mixture for producing heat energy in conventional equipment is feasible and beneficial for reduction emissions. (author)

  4. R13B1 and R114 exergy-enthalpy charts and their usefulness in a refrigerating-heating process analysis

    International Nuclear Information System (INIS)

    de Rossi, F.; Mastrullo, R.; Sasso, M.; Sibilio, S.

    1989-01-01

    R13B1 and R114 exergy-enthalpy diagrams in SI units based on data and equations published by the International Institute of Refrigeration are presented. The charts cover the ranges of 0.5 kPa to 15000 kPa and 120 degrees C to 180 degrees C for R13B1 and 0.8 kPa to 5000 kPa and -70 degrees C to 250 degrees C for R114. In this paper an analysis of a cascade refrigerating-heating compound system is included to illustrate the use of the charts

  5. Toxicity Data to Determine Refrigerant Concentration Limits

    Energy Technology Data Exchange (ETDEWEB)

    Calm, James M.

    2000-09-30

    This report reviews toxicity data, identifies sources for them, and presents resulting exposure limits for refrigerants for consideration by qualified parties in developing safety guides, standards, codes, and regulations. It outlines a method to calculate an acute toxicity exposure limit (ATEL) and from it a recommended refrigerant concentration limit (RCL) for emergency exposures. The report focuses on acute toxicity with particular attention to lethality, cardiac sensitization, anesthetic and central nervous system effects, and other escape-impairing effects. It addresses R-11, R-12, R-22, R-23, R-113, R-114, R-116, R-123, R-124, R-125, R-134, R-134a, R-E134, R-141b, R-142b, R-143a, R-152a, R-218, R-227ea, R-236fa, R-245ca, R-245fa, R-290, R-500, R-502, R-600a, R-717, and R-744. It summarizes additional data for R-14, R-115, R-170 (ethane), R-C318, R-600 (n-butane), and R-1270 (propylene) to enable calculation of limits for blends incorporating them. The report summarizes the data a nd related safety information, including classifications and flammability data. It also presents a series of tables with proposed ATEL and RCL concentrations-in dimensionless form and the latter also in both metric (SI) and inch-pound (IP) units of measure-for both the cited refrigerants and 66 zerotropic and azeotropic blends. They include common refrigerants, such as R-404A, R-407C, R-410A, and R-507A, as well as others in commercial or developmental status. Appendices provide profiles for the cited single-compound refrigerants and for R-500 and R-502 as well as narrative toxicity summaries for common refrigerants. The report includes an extensive set of references.

  6. Measurements of saturation densities in critical region and critical loci for binary R-32/125 and R-125/143a systems

    Energy Technology Data Exchange (ETDEWEB)

    Kishizawa, G.; Sato, H.; Watanabe, K.

    1999-05-01

    R-32/125 (difluoromethane/pentafluoroethane) and R-125/143a (pentafluoroethane/1,1,1-trifluoroethane) binary systems are promising alternative refrigerants to replace conventional refrigerants, i.e., R-22 and R-502. The saturated vapor- and liquid-density data in the critical region of these mixtures were measured using the visual observation of the miniscus disappearance in an optical cell. For the R-32/125 system, 35 saturation density data were measured at three compositions, 10, 35, and 50 mass % R-32. Nineteen saturation density data were also measured for R-125/143a (50/50 mass %). The critical temperatures and densities for these binary refrigerants were determined by taking into consideration the level and location of the meniscus disappearance as well as the intensity of the critical opalescence. Correlations to represent the critical loci of these binary refrigerants for an entire range of compositions have been developed. The experimental uncertainties of the saturation density data are estimated to be within 9 mK in temperature and 0.5 to 5.0 kg{center{underscore}dot}m{sup {minus}3} in density. The uncertainties of the critical temperature and density are estimated to be within 12 to 14 mK and 4 to 8 kg{center{underscore}dot}m{sup {minus}3}, respectively.

  7. Depicting mass flow rate of R134a /LPG refrigerant through straight and helical coiled adiabatic capillary tubes of vapor compression refrigeration system using artificial neural network approach

    Science.gov (United States)

    Gill, Jatinder; Singh, Jagdev

    2018-07-01

    In this work, an experimental investigation is carried out with R134a and LPG refrigerant mixture for depicting mass flow rate through straight and helical coil adiabatic capillary tubes in a vapor compression refrigeration system. Various experiments were conducted under steady-state conditions, by changing capillary tube length, inner diameter, coil diameter and degree of subcooling. The results showed that mass flow rate through helical coil capillary tube was found lower than straight capillary tube by about 5-16%. Dimensionless correlation and Artificial Neural Network (ANN) models were developed to predict mass flow rate. It was found that dimensionless correlation and ANN model predictions agreed well with experimental results and brought out an absolute fraction of variance of 0.961 and 0.988, root mean square error of 0.489 and 0.275 and mean absolute percentage error of 4.75% and 2.31% respectively. The results suggested that ANN model shows better statistical prediction than dimensionless correlation model.

  8. Auto-refrigerating cascade for superconducting applications

    International Nuclear Information System (INIS)

    Forrest, S.M.; Hall, P.H.; Missimer, D.J.

    1987-01-01

    Extremely low temperatures, in the range of 230 to 90 K, are achieved in a single circuit compression refrigeration system operated by a conventional compressor. The system relies upon a series of intermediate cooling stages. The refrigerant is a mixture and the system employs fractional condensation, distillation, phase separation and intermediate heat transfer. Each stage includes the steps of withdrawing a portion of the liquid condensate from the compressed vapor-liquid refrigerant mixture which enters the stage. The withdrawn condensate is then throttled to a lower pressure and is mixed with the refrigerant being recycled to the compressor from the final evaporator. Evaporating the throttled condensate absorbs heat from and at least partially condenses the compressed uncondensed vapor in the compressed mixture

  9. Process of decomposing an oil mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kubierschky, K

    1917-12-02

    A process is described for the decomposition of oil mixtures, and the like, by means of alcohol, characterized in that the subject mixture is brought into solution in high-grade alcohol, and this solution is washed countercurrent with dilute alcohol.

  10. Thermodynamic comparision of R744/R600a and R744/R600 used in mid-high temperature heat pump system

    Directory of Open Access Journals (Sweden)

    Fan Xiao-Wei

    2014-01-01

    Full Text Available The mid-high temperature heat pump provides hot water at a relatively high temperature using some industrial waste heat as its source. Now, the main refrigerants in this application are CFC114, HCFC123, and HCFC142b, etc., which are scheduled to be phased out due to their high ozone depletion potential and global warmth potential. Some studies have been conducted to find an eco-friendly alternative. In this paper, the natural non-azeotropic mixtures R744/R600a and R744/R600 are analyzed as alternatives. The performance of the heat pump system using new mixture is discussed and compared with those with CFC114, HCFC123, and HCFC142b. Under the given operating conditions, the maximum heating COP should occur at the mass fractions of 18/82 for R744/R600a and 10/90 for R744/R600. Both of their COP are higher than those with the refrigerants of CFC114, HCFC123, and HCFC142b. The COP and volumetric heating capacity of the system with R744/R600a are superior to those with R744/R600.

  11. Spectroscopic and Chemometric Analysis of Binary and Ternary Edible Oil Mixtures: Qualitative and Quantitative Study.

    Science.gov (United States)

    Jović, Ozren; Smolić, Tomislav; Primožič, Ines; Hrenar, Tomica

    2016-04-19

    The aim of this study was to investigate the feasibility of FTIR-ATR spectroscopy coupled with the multivariate numerical methodology for qualitative and quantitative analysis of binary and ternary edible oil mixtures. Four pure oils (extra virgin olive oil, high oleic sunflower oil, rapeseed oil, and sunflower oil), as well as their 54 binary and 108 ternary mixtures, were analyzed using FTIR-ATR spectroscopy in combination with principal component and discriminant analysis, partial least-squares, and principal component regression. It was found that the composition of all 166 samples can be excellently represented using only the first three principal components describing 98.29% of total variance in the selected spectral range (3035-2989, 1170-1140, 1120-1100, 1093-1047, and 930-890 cm(-1)). Factor scores in 3D space spanned by these three principal components form a tetrahedral-like arrangement: pure oils being at the vertices, binary mixtures at the edges, and ternary mixtures on the faces of a tetrahedron. To confirm the validity of results, we applied several cross-validation methods. Quantitative analysis was performed by minimization of root-mean-square error of cross-validation values regarding the spectral range, derivative order, and choice of method (partial least-squares or principal component regression), which resulted in excellent predictions for test sets (R(2) > 0.99 in all cases). Additionally, experimentally more demanding gas chromatography analysis of fatty acid content was carried out for all specimens, confirming the results obtained by FTIR-ATR coupled with principal component analysis. However, FTIR-ATR provided a considerably better model for prediction of mixture composition than gas chromatography, especially for high oleic sunflower oil.

  12. Study of thermodynamic properties of HFC refrigerant mixtures for Loretz-cycled niew generation air-conditioning equipment; Lorentz cycle ka shinsedai kucho kikiyo HFC kei kongo reibai no netsu rikigaku seishitsu ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, K; Sato, H [Keio University, Tokyo (Japan). Faculty of Science and Technology

    1997-02-01

    This paper describes thermodynamic properties of HFC refrigerant mixtures for Lorentz-cycled new generation air-conditioning equipment. Equipment has been completed for simultaneous measurement of density and vapor-liquid equilibrium property, accurate measurement of latent heat of vaporization, and accurate measurement of specific heat at constant pressure in liquid phase. Final adjustment and preliminary measurements are currently conducted. Through analytical investigation using actually measured data of thermodynamic properties of HFC refrigerant mixtures, five state equations were obtained, i.e., modified Peng-Robinson state equation which can reproduce the vapor-liquid equilibrium property of refrigerant mixtures, modified Patel-Teja state equation, Helmholtz function type state equation which is applicable in the whole fluid region of refrigerant mixtures, and so on. An evaluation test equipment has been fabricated as a trial for Lorentz-cycled air-conditioning equipments using HFC refrigerant mixtures, and demonstration test is conducted to confirm the validity. 9 refs., 5 figs.

  13. Study of change of refrigerant R22 in chiller units by simulation in EcosimPro

    International Nuclear Information System (INIS)

    Prieto, J.; Molina, C.; Olmedo, J.; Gavilan, C. J.

    2014-01-01

    On January 1, 2010 is forbidden to hold any stock of virgin R 2 2 refrigerant and it is also forbidden to use virgin R 2 2 refrigerant for the service and maintenance of equipment under the new European Community Regulation 20137/2000. On January 1, 2015 and stock of R 2 2, even if reclaimed or recycled, will be illegal to hold. In accordance with the European Community regulation, Cofrentes Nuclear Power Plant begins the R 2 2 retrofit. (Author)

  14. Dimensioning of flanged heat exchangers using the CYRANO software: pure refrigerants and mixtures; Dimensionnement des batteries a ailettes a l`aide du logiciel CYRANO: frigorigenes purs et melanges

    Energy Technology Data Exchange (ETDEWEB)

    Bensafi, A; Borg, S [CETIAT, Centre Technique des Industries Aerauliques et Thermiques, 69 - Villeurbanne (France)

    1998-12-31

    A software for the dimensioning and simulation of flanged heat exchangers is presented. This software divides the exchanger into pipe sections in which local values of physical properties of fluids and thermal exchange coefficients are used, and for which individual thermal-hydraulic performances are determined. CYRANO can be used for condensers, evaporators and monophase exchanges, with refrigerants like water, R22, R134a and R32/R125/R134a mixtures. The software can be used also in the case of specified complex circuits, equipped with smooth or grooved pipes and with smooth continuous, corrugated or slatted flanges with non-homogeneous air temperature and velocity distributions. The validation of CYRANO was performed on 7 exchangers with and without humidity condensation on the flanges. Comparisons with test results show that the average of errors in exchanged powers is of about 5%, and of about 30% in the case of internal pressure drops. Some simulations of exchangers with HFC mixtures are also presented. (J.S.) 34 refs.

  15. Dimensioning of flanged heat exchangers using the CYRANO software: pure refrigerants and mixtures; Dimensionnement des batteries a ailettes a l`aide du logiciel CYRANO: frigorigenes purs et melanges

    Energy Technology Data Exchange (ETDEWEB)

    Bensafi, A.; Borg, S. [CETIAT, Centre Technique des Industries Aerauliques et Thermiques, 69 - Villeurbanne (France)

    1997-12-31

    A software for the dimensioning and simulation of flanged heat exchangers is presented. This software divides the exchanger into pipe sections in which local values of physical properties of fluids and thermal exchange coefficients are used, and for which individual thermal-hydraulic performances are determined. CYRANO can be used for condensers, evaporators and monophase exchanges, with refrigerants like water, R22, R134a and R32/R125/R134a mixtures. The software can be used also in the case of specified complex circuits, equipped with smooth or grooved pipes and with smooth continuous, corrugated or slatted flanges with non-homogeneous air temperature and velocity distributions. The validation of CYRANO was performed on 7 exchangers with and without humidity condensation on the flanges. Comparisons with test results show that the average of errors in exchanged powers is of about 5%, and of about 30% in the case of internal pressure drops. Some simulations of exchangers with HFC mixtures are also presented. (J.S.) 34 refs.

  16. Bioremediation potential of a tropical soil contaminated with a mixture of crude oil and production water.

    Science.gov (United States)

    Alvarez, Vanessa Marques; Santos, Silvia Cristina Cunha Dos Santos; Casella, Renata da Costa; Vital, Ronalt Leite; Sebastin, Gina Vasquez; Seldin, Lucy

    2008-12-01

    A typical tropical soil from the northeast of Brazil, where an important terrestrial oil field is located, was accidentally contaminated with a mixture of oil and saline production water. To study the bioremediation potential in this area, molecular methods based on PCR-DGGE were used to determine the diversity of the bacterial communities in bulk and in contaminated soils. Bacterial fingerprints revealed that the bacterial communities were affected by the presence of the mixture of oil and production water, and different profiles were observed when the contaminated soils were compared with the control. Halotolerant strains capable of degrading crude oil were also isolated from enrichment cultures obtained from the contaminated soil samples. Twenty-two strains showing these features were characterized genetically by amplified ribosomal DNA restriction analysis (ARDRA) and phenotypically by their colonial morphology and tolerance to high NaCl concentrations. Fifteen ARDRA groups were formed. Selected strains were analyzed by 16S rDNA sequencing, and Actinobacteria was identified as the main group found. Strains were also tested for their growth capability in the presence of different oil derivatives (hexane, dodecane, hexadecane, diesel, gasoline, toluene, naphthalene, o-xylene, and p-xylene) and different degradation profiles were observed. PCR products were obtained from 12 of the 15 ARDRA representatives when they were screened for the presence of the alkane hydroxylase gene (alkB). Members of the genera Rhodococcus and Gordonia were identified as predominant in the soil studied. These genera are usually implicated in oil degradation processes and, as such, the potential for bioremediation in this area can be considered as feasible.

  17. Multi-ejector concept for R-744 supermarket refrigerators; Multi-Ejektoren Konzept fuer R-744 Supermarkt-Kaelteanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Hafner, Armin [SINTEF Energy Research, Trondheim (Norway); Foersterling, Sven [TLK-Thermo GmbH, Braunschweig (Germany); Banasiak, Krzystof [Silesian Univ. of Technology, Gliwice (Poland)

    2012-07-01

    Supermarkets are commercial buildings with major energy consumption and contribute also to relatively large direct emissions of greenhouse (GHG) through emissions of refrigerants from the refrigeration plants and the air conditioning system installed. The huge majority of these systems, which are installed in European supermarkets, are applying HFC-404A as working fluid. Average annual leakage rates in Europe are in the range of 15-20 % of the total charge. Worldwide the figure is about 30 % and HCFC-22 being the main refrigerant in use. Restrictions on the use of synthetic refrigerants are coming into force in several countries. There is a need for a natural refrigerant which allows for a safe investment in efficient refrigeration systems which will not be forced to be retrofitted by legislation in the future. Systems applying R-744 as the only refrigerant have been developed and more than 500 supermarkets exist in Europe, mainly in northern and mid-European countries. However, the systems still have large potential in development with respect to energy efficiency, heat recovery and cost efficiency. The paper describes the calculation method to identify the possible annual energy savings for different supermarket systems layout. The adoption of non-controlled ejectors and additional function such as heat recovery are evaluated. Results show relevant improvements in system efficiency when heat recovery has been adopted. Ejector usage is not widely spread at the moment. Thus, a theoretical analysis applying the programming language Modelica has been carried out. (orig.)

  18. Oil-free heat pump plants with R744 (CO{sub 2}); Oelfreie Waermepumpenanlagen mit R744 (CO{sub 2})

    Energy Technology Data Exchange (ETDEWEB)

    Hafner, Armin [SINTEF Energy Research, Trondheim (Norway)

    2011-07-01

    Refrigeration systems must have a certain oil level to ensure lubrication of mechanical components of the compressor. Some of the oil will escape from the compressor into the working fluid and thus into the cooling circuit (heat exchanger, tubes, header, etc.) The advantages of oil-free R744 refrigerators are assessed for different applications, e.g. industrial cooling (e.g. in supermarket), cooling during transport, cooling on board ships for production of cooled sea water, and in industrial heat pumps. The simpler design of oil-free systems will result in lower construction cost and also in a lower life cycle cost. The CREATIV project focussed on the development of an oil-free, hermetically sealed compressor. The compressor will be installed in the SINTEF-/NTNU laboratories at Trondheim in 2012 and will then be tested on site in several pilot projects. [German] In Kaelteanlagen muss eine bestimmte Menge an Oel vorhanden sein, um die Schmierung von mechanisch bewegten Teilen des Verdichters sicherzustellen. Dieses Oel wird hauptsaechlich im Verdichter bevorratet, jedoch gelangt ein nicht unwesentlicher Anteil mit dem Arbeitsmedium in den Kaeltemittelkreislauf. Somit befindet sich eine nicht vernachlaessigbare Menge an Schmiermittel in den Waermeuebertragern, Rohrleitungen, im Sammler etc. Die Vorteile von oelfreien R744-Kaelteanlagen im Vergleich zu konventionellen Kaelteanlagen werden fuer unterschiedliche Anwendungen bewertet: grosstechnische Kuehlung (z. B. Supermarktkuehlung), Transportkuehlung, an Bord von Schiffen bei der Produktion von gekuehltem Meerwasser (RSW) und von industriellen Waermepumpen. Aufgrund der viel einfacheren Bauweise von oelfreien Anlagen werden die Anlagenkosten meistens reduziert. Durch Reduzierung von Service- und Instandhaltungsarbeiten sowie einer verbesserten Systemleistung, die zu einem energieeffizienteren Betrieb fuehrt, sind die Gesamtkosten waehrend der Lebensdauer (Life Cycle Costs) einer oelfreien Anlage im Vergleich zu

  19. Taguchi Method for Development of Mass Flow Rate Correlation using Hydrocarbon Refrigerant Mixture in Capillary Tube

    Directory of Open Access Journals (Sweden)

    Shodiya Sulaimon

    2014-07-01

    Full Text Available The capillary tube is an important control device used in small vapor compression refrigeration systems such as window air-conditioners, household refrigerators and freezers. This paper develops a non-dimensional correlation based on the test results of the adiabatic capillary tube for the mass flow rate through the tube using a hydrocarbon refrigerant mixture of 89.3% propane and 10.7% butane (HCM. The Taguchi method, a statistical experimental design approach, was employed. This approach explores the economic benefit that lies in studies of this nature, where only a small number of experiments are required and yet valid results are obtained. Considering the effects of the capillary tube geometry and the inlet condition of the tube, dimensionless parameters were chosen. The new correlation was also based on the Buckingham Pi theorem. This correlation predicts 86.67% of the present experimental data within a relative deviation of -10% to +10%. The predictions by this correlation were also compared with results in published literature.

  20. Use of ATR-FTIR spectroscopy coupled with chemometrics for the authentication of avocado oil in ternary mixtures with sunflower and soybean oils.

    Science.gov (United States)

    Jiménez-Sotelo, Paola; Hernández-Martínez, Maylet; Osorio-Revilla, Guillermo; Meza-Márquez, Ofelia Gabriela; García-Ochoa, Felipe; Gallardo-Velázquez, Tzayhrí

    2016-07-01

    Avocado oil is a high-value and nutraceutical oil whose authentication is very important since the addition of low-cost oils could lower its beneficial properties. Mid-FTIR spectroscopy combined with chemometrics was used to detect and quantify adulteration of avocado oil with sunflower and soybean oils in a ternary mixture. Thirty-seven laboratory-prepared adulterated samples and 20 pure avocado oil samples were evaluated. The adulterated oil amount ranged from 2% to 50% (w/w) in avocado oil. A soft independent modelling class analogy (SIMCA) model was developed to discriminate between pure and adulterated samples. The model showed recognition and rejection rate of 100% and proper classification in external validation. A partial least square (PLS) algorithm was used to estimate the percentage of adulteration. The PLS model showed values of R(2) > 0.9961, standard errors of calibration (SEC) in the range of 0.3963-0.7881, standard errors of prediction (SEP estimated) between 0.6483 and 0.9707, and good prediction performances in external validation. The results showed that mid-FTIR spectroscopy could be an accurate and reliable technique for qualitative and quantitative analysis of avocado oil in ternary mixtures.

  1. Numerical investigation of boiling heat transfer on hydrocarbon mixture refrigerant in vertical rectangular minichannel

    OpenAIRE

    Huixing Li; Yu Liu

    2016-01-01

    In order to investigate the characteristics of boiling heat transfer for hydrocarbon mixture refrigerant in plate-fin heat exchanger which is used in the petrochemical industry field, a model was established on boiling heat transfer in vertical rectangular channel. The simulated results were compared with the experimental data from literature. The results show that the deviation between the simulated results and experimental data is within ±15%. Meanwhile, the characteristic of boiling heat t...

  2. Experimental investigations on automobile air conditioners working with R134a and R290/R600a as an alternative

    Directory of Open Access Journals (Sweden)

    Kandhaswamy Karthikeyan

    2017-01-01

    Full Text Available In this work, the performance of R134a based automobile air conditioning system has been evaluated by retrofitted with R290/R600a mixture (in the ratio of 50:50, by mass, as an alternative. The performance was evaluated at five different operating speeds (1000, 1500, 2000, 2500, and 3000, which covers the entire range of working conditions with four different cabin load (100, 200, 300, and 400 W. The condenser inlet air temperature was varied in the range between 30 and 50°C, which covers the entire climatic variations in Coimbatore city of India. The performance characteristics such as, refrigerating effect, coefficient of performance, compressor power consumption, and compressor discharge temperatures were considered for comparison. The results showed that, hydrocarbon mixture has faster cooling rate due to its high latent heat of vaporization, 5% higher coefficient of performance due to higher refrigeration effect, 8-10 K lower compressor discharge temperature due to its lower specific heat ratio with 5% lower compressor power consumption due to its lower viscosity and lower liquid density. The charge requirement of R290/R600a mixture is about 50% less compared to R134a. However, the mixture composition is considered as an interment replacement in automobile air conditioners due to composition shift under leak-age conditions. Hence, R290/R600a mixture is considered as an interim energy efficient and environment friendly option in R134a automobile air conditioners to extend its life.

  3. Thermodynamic analysis of hydrocarbon refrigerants in a sub-cooling refrigeration system

    Directory of Open Access Journals (Sweden)

    BUKOLA O. BOLAJI

    2013-06-01

    Full Text Available In this study, the performance simulation of some hydrocarbon refrigerants (R290, R600 and R600a as alternatives to R134a in refrigeration system with sub-cooling is conducted by thermodynamic calculation of performance parameters using the REFPROP software. The results obtained showed that the saturated vapour pressure and temperature characteristic profiles for R600 and R600a are very close to that of R134a. The three hydrocarbon refrigerants exhibited very high refrigerating effect and condenser duty than R134a. The best of these parameters was obtained using R600. The discharge temperatures obtained using R600 and R600a were low, while that of R290 was very much higher. The highest coefficient of performance (COP and relative capacity index were obtained using R600. Average COPs of R600 and R600a are 4.6 and 2.2% higher than that of R134a, respectively. The performances of R600 and R600a in system were better than those of R134a and R290. The best performance was obtained using R600 in the system.

  4. Desolventizing of soybean oil/azeotrope mixtures using ceramic membranes.

    Science.gov (United States)

    de Melo, Jonas R M; Tiggeman, Lidia; Rezzadori, Katia; Steffens, Juliana; Palliga, Marshall; Oliveira, J Vladimir; Di Luccio, Marco; Tres, Marcus V

    2017-08-01

    This work investigates the use of ceramic membranes with different molecular weight cut-offs (MWCOs: 5, 10 and 20 kDa) to desolventize azeotropic solvent mixtures (ethanol/n-hexane and isopropyl alcohol/n-hexane) from soybean oil/azeotrope micelles. Results show that a decrease in the MWCO of a membrane and an increase in the solvent mass ratio in the mixture resulted in a significant reduction in the permeate flux. The 20 kDa membrane presented the highest permeate flux, 80 and 60 kg/m 2 h for the soybean oil/n-hexane/isopropyl alcohol and soybean oil/n-hexane/ethanol azeotropes, respectively, for an oil to solvent ratio of 1:3 (w/w). The highest oil retention was found using the n-hexane/isopropyl alcohol azeotrope, around 25% in the membrane with the lowest MWCO, that is, 5 kDa. It is shown that the azeotropic mixtures provided intermediate characteristics compared to the original pure solvent behavior.

  5. Heating Performance Analysis of a Geothermal Heat Pump Working with Different Zeotropic and Azeotropic Mixtures

    Directory of Open Access Journals (Sweden)

    Robert Bedoić

    2018-06-01

    Full Text Available The aim of the paper is to examine the possibility of application of the spreadsheet calculator and Reference Fluid Thermodynamic and Transport Properties database to a thermodynamic process. The heating process of a real soil-to-water heat pump, including heat transfer in the borehole heat exchanger has been analysed. How the changes of condensing temperature, at constant evaporating temperature, influence the following: heating capacity, compressor effective power, heat supplied to evaporator, compression discharge temperature and coefficient of performance, are investigated. Also, the energy characteristics of a heat pump using different refrigerants for the same heating capacity and the same temperature regime are compared. The following refrigerants are considered: two zeotropic mixtures, R407C and R409A, a mixture with some zeotropic characteristics, R410A, and an azeotropic mixture, R507A.

  6. Fuel properties of biodiesel from vegetable oils and oil mixtures. Influence of methyl esters distribution

    International Nuclear Information System (INIS)

    Martínez, G.; Sánchez, N.; Encinar, J.M.; González, J.F.

    2014-01-01

    In this work, the quality of biodiesel produced by basic transesterification from several vegetable oils (soybean, rapeseed, sunflower, high oleic sunflower, Cynara Cardunculus L., Brassica Carinata and Jatropha Curca) cultivated in Extremadura has been studied in detail. The influence of raw material composition on properties such as density, viscosity, cetane number, higher heating value, iodine and saponification values and cold filter plugging point has been verified. Other biodiesel properties such as acid value, water content and flash and combustion points were more dependent on characteristics of production process. Biodiesel produced by rapeseed, sunflower and high oleic sunflower oils transesterification have been biofuels with better properties according to Norm EN 14214. Finally, it has been tested that it is possible to use oils mixtures in biodiesel production in order to improve the biodiesel quality. In addition, with the same process conditions and knowing properties of biodiesel from pure oils; for biodiesel from oils mixtures, its methyl esters content, and therefore properties dependent this content can be predicted from a simple mathematical equation proposed in this work. - Highlights: • Biodiesel quality produced by basic transesterification from vegetable oils. • We examine influences of methyl esters distribution on biodiesel properties. • Biofuels from soybean, sunflower and rapeseed oils were with better properties. • Oils mixtures improve biodiesel quality to fulfill Norm EN 14214. • An equation to predict properties of biodiesel from oil mixtures is proposed

  7. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1997-02-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  8. Classification of refrigerants; Classification des fluides frigorigenes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This document was made from the US standard ANSI/ASHRAE 34 published in 2001 and entitled 'designation and safety classification of refrigerants'. This classification allows to clearly organize in an international way the overall refrigerants used in the world thanks to a codification of the refrigerants in correspondence with their chemical composition. This note explains this codification: prefix, suffixes (hydrocarbons and derived fluids, azeotropic and non-azeotropic mixtures, various organic compounds, non-organic compounds), safety classification (toxicity, flammability, case of mixtures). (J.S.)

  9. Experimental comparison between R409A and R437A performance in a heat pump unit

    Directory of Open Access Journals (Sweden)

    Duarte M. V.

    2017-04-01

    Full Text Available This paper reports an experimental comparison between the use of the refrigerants R409A and R437A in a heat pump unit designed and developed to work with R12. Although the use of both refrigerants in new equipments were abolished in EU and US according the new F-Gas Regulation of EU and SNAP, they still being used as options for R12 in old equipments, especially in developing countries. Both refrigerants were studied for the same test conditions, according to two groups of tests: group A (variation of the heat source temperature and group B (variation of refrigerant flow rate. The results obtained showed that the R437A presents a higher discharge pressure and a lower discharge temperature. The heating and cooling capacities of both refrigerants were similar, as well as the exergetic efficiency. For the group A of tests the COP of both refrigerants was similar and for the group B of tests the R409A presented an average COP 15% higher. According to the results obtained it is recommended the use of R409A in old equipments (as transition refrigerant until the acquisition of equipments operating with refrigerants with low-GWP becomes technically and economic feasible.

  10. System performance with R407A, R407B, R407C compared to R22

    DEFF Research Database (Denmark)

    Knudsen, Hans Jørgen Høgaard

    1997-01-01

    both the cooling capacity and COP are smaller then the cooling capacity and COP with R22. The cooling capacity for R407A and R407B is lower than the capacity for R22 for brine temperatures less than 0 C and higher then the cooling capacity for R22 for brine temperatures higher than 0 C. The COP for R......407A and R407B er lower than the COP for R22.The volumetric and isentropic efficiency of the compressor are with mixture higher than the volumetric and isentropic efficiency with R22.......The article presents the results obtained by substituting R22 with mixture of R32/R125/R134A (R407A, R407B and R407C) in an existing refrigeration plant. Cooling capacity, coefficient of performance and heat transfer coefficient in the evaporator have been measured.The results show that for R407C...

  11. Experimental Assessment of residential split type air-conditioning systems using alternative refrigerants to R-22 at high ambient temperatures

    International Nuclear Information System (INIS)

    Joudi, Khalid A.; Al-Amir, Qusay R.

    2014-01-01

    Highlights: • R290, R407C and R410A in residential split A/C units at high ambient. • 1 and 2 TR residential air conditioners with R22 alternatives at high ambient. • Residential split unit performance at ambients up to 55 °C with R22 alternatives. - Abstract: Steady state performance of residential air conditioning systems using R22 and alternatives R290, R407C, R410A, at high ambient temperatures, have been investigated experimentally. System performance parameters such as optimum refrigerant charge, coefficient of performance, cooling capacity, power consumption, pressure ratio, power per ton of refrigeration and TEWI environmental factor have been determined. All refrigerants were tested in the cooling mode operation under high ambient air temperatures, up to 55 °C, to determine their suitability. Two split type air conditioner of 1 and 2 TR capacities were used. A psychrometric test facility was constructed consisting of a conditioned cool compartment and an environmental duct serving the condenser. Air inside the conditioned compartment was maintained at 25 °C dry bulb and 19 °C wet bulb for all tests. In the environmental duct, the ambient air temperature was varied from 35 °C to 55 °C in 5 °C increments. The study showed that R290 is the better candidate to replace R22 under high ambient air temperatures. It has lower TEWI values and a better coefficient of performance than the other refrigerants tested. It is suitable as a drop-in refrigerant. R407C has the closest performance to R22, followed by R410A

  12. System performance with R407A, R407B, R407C compared to R22

    DEFF Research Database (Denmark)

    Knudsen, Hans Jørgen Høgaard

    1997-01-01

    been determined.The results show that for R407C both the cooling capacity and the COP are smaller than the cooling capacity and COP for R22. The cooling capacity for R407A and for R407B is lower then the cooling capacity for R22 for brine temperatures less than 0 C and higher than the capacity for R22...... for brine temperatures higher than 0 C. The COP for R407A and 407B are lower than the COP for R22.The volumetriv and isentropic efficiency of the compressor are with mixtures higher than the volumetric and isentropic efficiency with R22.......The paper presents the results obtained by substituting R22 with mixtures of R32/R124/134a (R407A, R407B and R407C) in an existing refrigeration plant. The cooling water flow and cooling water inlet temperature together with the brine flow and brine inlet temperature have been kept on a value...

  13. Energy and environmental performance assessment of R744 booster supermarket refrigeration systems operating in warm climates

    DEFF Research Database (Denmark)

    Gullo, Paride; Elmegaard, Brian; Cortella, Giovanni

    2016-01-01

    This paper presents a theoretical comparison among different commercial refrigeration systems in terms of annual energy consumption and environmental impact. Eight configurations were studied: a R744/R134a cascade refrigeration system (baseline), a conventional and an improved R744 booster system...... as on the running modes of a conventional European supermarket. A transition zone, which occurred between sub critical and transcritical operations, was adopted.The results showed that all the enhanced configurations may achieve a comparable energy saving to the one of the baseline in both the selected locations...

  14. Utilization of the heat of mixing in open-circuit throttle refrigerators

    International Nuclear Information System (INIS)

    Zhakharov, N.D.; Anikeev, G.N.; Grezin, A.K.

    1986-01-01

    Open-circuit throttle refrigerators based on gas mixtures operate, as a rule, according to a single-stream scheme. The refrigerating effect is determined by the isothermal throttling effect of the mixture in the cylinder under the conditions at the inlet to the cryogenic unit. The authors use the heat of mixing of the cryogenic mixtures to increase the available refrigerating effect. Data are presented on mixtures of nitrogen and Freon-13; the thermodynamic properties of these compounds have been investigated experimentally over a wide range of parameters. It was found that in the case of correct selection of the scheme and complex optimization of the parameters, two-stream throttle refrigerators exceed the single-stream throttle refrigerators by at least a factor of 1.5 with respect to relative useful energy. With account taken of the design, technological, and operational parameters, that which is most promising is the scheme with mixing of the components in reverse flow

  15. HFC perspectives in air-conditioning and refrigeration; Perspectives HFC en A/C et refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, P [ELF Atochem, Centre d` Application de Lavallois, 92 (France)

    1998-12-31

    This paper is a series of transparencies dealing with the development of substitutes for the replacement of the R-22 refrigerant in air-conditioning systems (R-134a, R-407C, R-410A), and in industrial refrigeration systems of agriculture and food industry (R-134a and R-404A). (J.S.)

  16. HFC perspectives in air-conditioning and refrigeration; Perspectives HFC en A/C et refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, P. [ELF Atochem, Centre d`Application de Lavallois, 92 (France)

    1997-12-31

    This paper is a series of transparencies dealing with the development of substitutes for the replacement of the R-22 refrigerant in air-conditioning systems (R-134a, R-407C, R-410A), and in industrial refrigeration systems of agriculture and food industry (R-134a and R-404A). (J.S.)

  17. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1998-08-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufactures and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on many refrigerants including propane, ammonia, water, carbon dioxide, propylene, ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  18. Effect of randomization of mixtures of butter oil and vegetable oil on absorption and lipid metabolism in rats

    DEFF Research Database (Denmark)

    Becker, C.; Lund, Pia; Hølmer, Gunhild Kofoed

    2001-01-01

    of the dietary fats compared. Data on the fate of such lipids beyond the bloodstream is rather scarce and animal model studies are needed. Aim of the study To compare the metabolism of butter oil and mixtures of butter and rapeseed oil, native or randomized, in a model. The regiospecific fatty acid distribution...... present in dietary fats was followed through absorption, chylomicron formation, and deposition in adipose tissue and in different liver lipids (triacylglycerols, phospholipids, and cholesterol esters). Methods Rats were fed for 6 weeks from weaning either butter oil (BO), a butteroil- rapeseed oil mixture...... (interesterification) of butter oil with rapeseed oil (65:35 w/w) for use as edible fat did not have any impact on the fatty acid composition beyond the chylomicron step when compared to the native mixture....

  19. Energetic, economic and environmental impacts of using nanorefrigerant in domestic refrigerators in Malaysia

    International Nuclear Information System (INIS)

    Javadi, F.S.; Saidur, R.

    2013-01-01

    Highlights: • Energy saving of using nanorefrigerant except of normal refrigerant in domestic refrigerator is investigated in Malaysia. • Using nanorefrigerant cause to reduce energy consumption of domestic refrigerator. • The maximum energy saving would be happen in case of using 0.1% TiO 2 –mineral oil–R134a nanorefrigerant. • Emission reduction is an environmental effect of using nanorefrigerant. - Abstract: The electricity demand in the residential sector has increased rapidly in recent years in Malaysia. This is mainly due to lifestyle improvement; and is also associated with the increase in the number of domestic refrigerators in this tropical country. This paper investigates the effect of using nanorefrigerant on energy saving in domestic refrigerators and emission reduction of greenhouse gases as an environmental viewpoint. The combination of R-134a refrigerant with TiO 2 and Al 2 O 3 nanoparticles with different mass fractions was scrutinized as a new refrigerant. It has been found that the energy saving using nanorefrigerant (0.1% TiO 2 nanoparticle/Mineral Oil) would be greater than normal refrigerant, with 10,863 MW h reduction in energy consumption by the year 2030. In this regard, this technology will be environmentally friendly by decreasing greenhouse emission, especially in terms of carbon dioxide. Thus, nanorefrigerant can help to increase the performance of domestic refrigerators and reduce energy consumption. Favorable effect on emission reduction and economic justification were concluded

  20. [Study of Determination of Oil Mixture Components Content Based on Quasi-Monte Carlo Method].

    Science.gov (United States)

    Wang, Yu-tian; Xu, Jing; Liu, Xiao-fei; Chen, Meng-han; Wang, Shi-tao

    2015-05-01

    Gasoline, kerosene, diesel is processed by crude oil with different distillation range. The boiling range of gasoline is 35 ~205 °C. The boiling range of kerosene is 140~250 °C. And the boiling range of diesel is 180~370 °C. At the same time, the carbon chain length of differentmineral oil is different. The carbon chain-length of gasoline is within the scope of C7 to C11. The carbon chain length of kerosene is within the scope of C12 to C15. And the carbon chain length of diesel is within the scope of C15 to C18. The recognition and quantitative measurement of three kinds of mineral oil is based on different fluorescence spectrum formed in their different carbon number distribution characteristics. Mineral oil pollution occurs frequently, so monitoring mineral oil content in the ocean is very important. A new method of components content determination of spectra overlapping mineral oil mixture is proposed, with calculation of characteristic peak power integrationof three-dimensional fluorescence spectrum by using Quasi-Monte Carlo Method, combined with optimal algorithm solving optimum number of characteristic peak and range of integral region, solving nonlinear equations by using BFGS(a rank to two update method named after its inventor surname first letter, Boyden, Fletcher, Goldfarb and Shanno) method. Peak power accumulation of determined points in selected area is sensitive to small changes of fluorescence spectral line, so the measurement of small changes of component content is sensitive. At the same time, compared with the single point measurement, measurement sensitivity is improved by the decrease influence of random error due to the selection of points. Three-dimensional fluorescence spectra and fluorescence contour spectra of single mineral oil and the mixture are measured by taking kerosene, diesel and gasoline as research objects, with a single mineral oil regarded whole, not considered each mineral oil components. Six characteristic peaks are

  1. Modern reciprocating compressors for the use of high pressure refrigerants (e.g. R410A, CO2). Criteria for construction and lubricating systems; Moderne zuigercompressoren voor de toepassing van hogedrukkoudemiddelen (zoals R410A, CO2). Eisen aan constructie en smeersystemen

    Energy Technology Data Exchange (ETDEWEB)

    Van der Lande, C. [Uniechemie, Apeldoorn (Netherlands); Grosse-Kracht, R. [Bitzer, Kuehlmaschinenbau, Sindelfingen (Germany)

    2005-09-01

    The use of high pressure refrigerants like R410A (air conditioning and chillers) and CO2 (low temperature cascade in supermarkets) demands changes in the standard fine reciprocating compressors. The design accounts essential criteria like thermodynamic and physical properties and the interaction between refrigerants and applied lubricants. These are high pressures, the mass flow, the vapour density, the high specific cooling capacity, the power consumption and the temperatures of oil and discharge gasses. [Dutch] De toepassing van R410A (in de klimaat-techniek) en CO2 (in lagetemperatuurcascade-installaties voor de supermarkttoepassing) vereist een aanpassing van standaard semi-hermetische zuigercompressoren om de fysische- en thermodynamische eigenschappen van het koudemiddel tot hun recht te laten komen. Dit zijn vooral de optredende drukken, de massastroom, de dampdichtheid, de hoge specifieke koelcapaciteit, het opgenomen vermogen en de olie- en persgastemperatuur.

  2. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1996-04-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates. Citations in this report are divided into the following topics: thermophysical properties; materials compatibility; lubricants and tribology; application data; safety; test and analysis methods; impacts; regulatory actions; substitute refrigerants; identification; absorption and adsorption; research programs; and miscellaneous documents. Information is also presented on ordering instructions for the computerized version.

  3. Application of Cascade Refrigeration System with Mixing Refrigerant in Cold Air Cutting

    Science.gov (United States)

    Yang, Y.; Tong, M. W.; Yang, G.; Wang, X. P.

    In the mechanical cutting process, the replacement of traditional cutting solution with cold air can avoid the pollution of environment. In order to high efficient the refrigerating device and flexible adjust the temperature of cold air, it is necessary to use cascade refrigeration system to supply cool quantity for the compressed air. The introduction of a two-component non-azeotropic mixing refrigerant into the cryogenic part of the cascade system, can effectively solve the problems of the system working at too high pressure and the volume expanding of refrigerant in case of the cascade refrigeration sets closed down. However, the filling ratio of mixing refrigerants impact on the relationships among the closing down pressure, refrigerating output and refrigerating efficiency. On the basis of computing and experiment, the optimal mixing ratio of refrigerant R22/R13 and a low temperature of -60° were obtained in this study. A cold air injecting device possessing high efficiency in energy saving has also been designed and manufactured. The cold air, generated from this cascade system and employed in a cutting process, takes good comprehensive effects on machining and cutting.

  4. Migration of carbon nanotubes from liquid phase to vapor phase in the refrigerant-based nanofluid pool boiling

    Directory of Open Access Journals (Sweden)

    Peng Hao

    2011-01-01

    Full Text Available Abstract The migration characteristics of carbon nanotubes from liquid phase to vapor phase in the refrigerant-based nanofluid pool boiling were investigated experimentally. Four types of carbon nanotubes with the outside diameters from 15 to 80 nm and the lengths from 1.5 to 10 μm were used in the experiments. The refrigerants include R113, R141b and n-pentane. The oil concentration is from 0 to 10 wt.%, the heat flux is from 10 to 100 kW·m-2, and the initial liquid-level height is from 1.3 to 3.4 cm. The experimental results indicate that the migration ratio of carbon nanotube increases with the increase of the outside diameter or the length of carbon nanotube. For the fixed type of carbon nanotube, the migration ratio decreases with the increase of the oil concentration or the heat flux, and increases with the increase of the initial liquid-level height. The migration ratio of carbon nanotube increases with the decrease of dynamic viscosity of refrigerant or the increase of liquid phase density of refrigerant. A model for predicting the migration ratio of carbon nanotubes in the refrigerant-based nanofluid pool boiling is proposed, and the predictions agree with 92% of the experimental data within a deviation of ±20%.

  5. Characterisation of Oil-Gas Mixtures by Raman Spectroscopy

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    2004-01-01

    . The present project deals with development of a technique for quick analysis of oil-gas mixtures. The main emphasis is laid on characterisation of gas phases in equilibrium with oil at high pressures and high temperatures by Raman spectroscopy. The Raman technique has a great potential of being useful, due...

  6. A solar absorption refrigeration system operating with the mixture ammonia-lithium nitrate

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, W.; Martinez, F.; Garcia-Valladares, O. [Centro de Investigacion en Energia de la Univ. Nacional Autonoma de Mexico, Mor (Mexico); Rivera, C.O. [Univ. Veracruzana, Campus Coatzacoalcos (Mexico)

    2007-07-01

    An intermittent solar absorption refrigeration system for ice production operating with the ammonia-lithium nitrate mixture has been developed in the Centro de Investigacion en Energia of the Universidad Nacional Autonoma de Mexico. The system consists basically of a compound parabolic concentrator (CPC), a generator-absorber, a condenser, a condensate tank, an expansion valve and an evaporator. The system was evaluated in sunny days with insolations above 20 MJ/m{sup 2}-day at different condenser temperatures. The generator temperatures varied from 108 to 121 C and the evaporator temperatures inside the camera from -8 to 0 C. The coefficients of performance (COP) varied from 0.13 to 0.26 depending of the operating temperatures of the system and the solar irradiation. (orig.)

  7. Magnetic refrigeration apparatus with belt of ferro or paramagnetic material

    Science.gov (United States)

    Barclay, John A.; Stewart, Walter F.; Henke, Michael D.; Kalash, Kenneth E.

    1987-01-01

    A magnetic refrigerator operating in the 12 to 77K range utilizes a belt which carries ferromagnetic or paramagnetic material and which is disposed in a loop which passes through the center of a solenoidal magnet to achieve cooling. The magnetic material carried by the belt, which can be blocks in frames of a linked belt, can be a mixture of substances with different Curie temperatures arranged such that the Curie temperatures progressively increase from one edge of the belt to the other. This magnetic refrigerator can be used to cool and liquefy hydrogen or other fluids.

  8. Condensation of nano-refrigerant inside a horizontal tube

    Science.gov (United States)

    Darzi, Milad; Sadoughi, M. K.; Sheikholeslami, M.

    2018-05-01

    In this paper, condensing pressure drop of refrigerant-based nanofluid inside a tube is studied. Isobutene was selected as the base fluid while CuO nanoparticles were utilized to prepare nano-refrigerant. However, for the feasibility of nanoparticle dispersion into the refrigerant, Polyester oil (POE) was utilized as lubricant oil and added to the pure refrigerant by 1% mass fraction. Various values of mass flux, vapor quality, concentration of nanoparticle are investigated. Results indicate that adding nanoparticles leads to enhance frictional pressure drop. Nanoparticles caused larger pressure drop penalty at relatively lower vapor qualities which may be attributed to the existing condensation flow pattern such that annular flow is less influenced by nanoparticles compared to intermittent flow regime.

  9. Combined cold compressor/ejector helium refrigerator cycle

    International Nuclear Information System (INIS)

    Schlafke, A.P.; Brown, D.P.; Wu, K.C.

    1984-01-01

    This chapter demonstrates how the use of a cold compressor in series with an ejector is an effective way to produce the desired low pressure in a helium refrigeration system. The cold compressor is tentatively located at the low pressure side below the J-T heat exchanger. The ejector is the first stage and the cold compressor is the second stage of the two-stage pumping system. A centrifugal, oil-bearing type compressor was installed on the R and D refrigerator at the Brookhaven National Laboratory. It is determined that the combined cold compressor and ejector system produces a lower temperature on the same load or more cooling at the same temperature compared with a system which uses an ejector alone. Results of the test showed a gain of 20%

  10. Comparative Study of Breakdown Voltage of Mineral, Synthetic and Natural Oils and Based Mineral Oil Mixtures under AC and DC Voltages

    Directory of Open Access Journals (Sweden)

    Abderrahmane Beroual

    2017-04-01

    Full Text Available This paper deals with a comparative study of AC and DC breakdown voltages of based mineral oil mixtures with natural and synthetic esters mainly used in high voltage power transformers. The goal was to analyze the performances of oil mixtures from the dielectric withstand point of view and to predict the behavior of transformers originally filled with mineral oil and re-filled with synthetic or natural ester oils when emptied for maintenance. The study concerns mixtures based on 20%, 50%, and 80% of natural and synthetic ester oils. AC breakdown voltages were measured using a sphere-sphere electrode system according to IEC 60156 specifications; the same specification was adopted for DC measurements since there is no standard specifications for this voltage waveform. A statistical analysis of the mean values, standard deviations, and histograms of breakdown voltage data was carried out. The Normal and Weibull distribution functions were used to analyze the experimental data and the best function that the data followed was used to estimate the breakdown voltage with risk of 1%, 10%, and 50% probability. It was shown that whatever the applied voltage waveforms, ester oils always have a significantly higher breakdown voltage than mineral oil. The addition of only 20% of natural or synthetic ester oil was sufficient to considerably increase the breakdown voltage of mineral oil. The dielectric strength of such a mixture is much higher than that of mineral oil alone and can reach that of ester oils. From the point of view of dielectric strength, the mixtures constitute an option for improving the performance of mineral oil. Thus, re-filling of transformers containing up to 20% mineral oil residues with ester oils, does not present any problem; it is even advantageous when considering only the breakdown voltage. Under AC, the mixtures with natural ester always follow the behavior of vegetable oil alone. With the exception of the 20% mixture of natural

  11. Performance of R290 and R1270 for R22 applications with evaporator and condenser temperature variation

    International Nuclear Information System (INIS)

    Park, Ki Jung; Jung, Dong Soo

    2008-01-01

    In this study, therma l performance of two hydrocarbon refrigerants of R290 and R1270 was measured in an attempt to substitute R22. They were tested in a heat pump bench tester of 1 ton capacity with a hermetic rotary compressor. Water and water/glycol mixture were employed as the secondary heat transfer fluids in the test bench. All tests were conducted under the same external conditions simulating three different air-conditioning and heat pumping conditions. Test results show that the coefficient of performance of these hydrocarbon refrigerants is up to 11.5% higher than that of R22 under all conditions. Refrigeration capacity of R290 is up to 8.2% lower than that of R22 under normal airconditioning and heat pumping conditions. Under extremely cold temperature conditions, however, the capacity of R290 is 5% higher than that of R22. On the other hand, the capacity of R1270 is similar to that of R22 under all conditions. Compressor discharge temperatures of these hydrocarbons are reduced by 14-31 .deg. C as compared to R22. The amount of charge is reduced up to 58% as compared to R22. Overall, these hydrocarbons provide good performance with reasonable energy savings without any environmental problems and thus can be used as long-term alternatives for residential air-conditioning and heat pumping applications

  12. Transesterification of camelina sativa oil with supercritical alcohol mixtures

    International Nuclear Information System (INIS)

    Sun, Yingqiang; Ponnusamy, Sundaravadivelnathan; Muppaneni, Tapaswy; Reddy, Harvind K.; Wang, Jun; Zeng, Zheling; Deng, Shuguang

    2015-01-01

    Highlights: • Transesterification of camelina oil under supercritical methanol/ethanol and 1-butanol mixture conditions. • Chemical composition of fatty acid methyl esters, ethyl esters and butyl esters. • Effect of different alcohol molar ratio on biodiesel yields. • Effect of different alcohol molar ratio on physical properties of biodiesel products. - Abstract: The transesterification of camelina sativa oil with methanol–1-butanol, and ethanol–1-butanol alcohol mixtures under supercritical conditions have been studied in order to maximize biodiesel yield and improve biodiesel quality. The influence of the variation of the molar ratio of methanol–1-butanol and ethanol–1-butanol from 1:0, 3:1, 2:1, 1:1, 1:2, to 0:1 on the yield of free fatty methyl esters/free fatty ethanol esters–free fatty acid butyl esters, the composition of the biodiesel blend mixtures, and the physical properties of the biodiesel have been investigated at the reaction temperature of 290 °C, reaction time of 30 min, and the initial reaction pressure of 500 psi. A maximum yield of 86.14 wt% for free fatty acid methyl esters–free fatty acid butyl esters with the optimum cold property can be obtained at the molar ratio of methanol–1-butanol of 0.5–0.9. Also, a maximum yield of 85.60 wt% for free fatty ethyl esters–free fatty butyl esters with the lowest pour point can be achieved at the molar ratio of ethanol–1-butanol in the range of 0.5–0.7

  13. Two-component mixture model: Application to palm oil and exchange rate

    Science.gov (United States)

    Phoong, Seuk-Yen; Ismail, Mohd Tahir; Hamzah, Firdaus Mohamad

    2014-12-01

    Palm oil is a seed crop which is widely adopt for food and non-food products such as cookie, vegetable oil, cosmetics, household products and others. Palm oil is majority growth in Malaysia and Indonesia. However, the demand for palm oil is getting growth and rapidly running out over the years. This phenomenal cause illegal logging of trees and destroy the natural habitat. Hence, the present paper investigates the relationship between exchange rate and palm oil price in Malaysia by using Maximum Likelihood Estimation via Newton-Raphson algorithm to fit a two components mixture model. Besides, this paper proposes a mixture of normal distribution to accommodate with asymmetry characteristics and platykurtic time series data.

  14. Condensation of refrigerants in horizontal microfin tubes: comparison of prediction methods for heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H S; Honda, H [Kyushu University, Fukuoka (Japan). Institute of Advanced Material Study

    2003-06-01

    A comparison was made between the predictions of previously proposed empirical correlations and theoretical model and available experimental data for the heat transfer coefficient during condensation of refrigerants in horizontal microfin tubes. The refrigerants tested were R11, R123, R134a, R22 and R410A. Experimental data for six tubes with the tube inside diameter at fin root of 6.49-8.8 8 mm, the fin height of 0.16-0.24 mm, fin pitch of 0.34-0.53 mm and helix angle of groove of 12-20{sup o} were adopted. The r.m.s. error of the predictions for all tubes and all refrigerants decreased in the order of the correlations proposed by Luu and Bergies [ASHRAE Trans. 86 (1980) 293], Cavallini et al. Condensation of new refrigerants inside smooth and enhanced tubes. In: Proc. 19th Int. Cong. Refrigeration, vol. IV, Hague, The Netherlands, 1995. p. 105-114, Shikazono et al. [Trans. Jap. Sco. Mech. Engrs. 64 (1995) 196], Kedzierski and Goncalves [J. Enhanced Heat Transfer 6 (1999) 16], Yu and Koyama [Yu J, Koyama S. Condensation heat transfer of pure refrigerants in microfin tubes. In: Proc. Int. Refrigeration Conference at Purdue Univ., West Lafayette, USA, 1998. p. 325-330], and the theoretical model proposed by Wang et al. [Int. J. Heat Mass Transfer 45 (2002) 1513]. (author)

  15. An experimental and theoretical study on an injection-assisted air-conditioner using R32 in the refrigeration cycle

    International Nuclear Information System (INIS)

    Qv, Dehu; Dong, Bingbing; Cao, Lin; Ni, Long; Wang, Jijin; Shang, Runxin; Yao, Yang

    2017-01-01

    Highlights: • An advanced injection-assisted air-conditioner (IAC) using R32 was proposed. • In the whole day-night cycle, cooling capacity and energy efficiency ratio of the IAC were enhanced dramatically. • The injection duration of 8 s maximized the IAC cooling potential. • Two-phase injection attained the highest exergetic efficiency approximating 50% or more. • The economic and environmental benefits of the IAC were demonstrated. - Abstract: An air-conditioner (AC) that uses refrigerant R32 assisted with one-phase vapor injection shows high energy efficiency and low discharge temperature in the heat-pump cycle, but the performance is not satisfactory in the refrigeration cycle. In this study, an improved injection cycle consisting of one-phase vapor injection mode and two-phase injection mode is proposed and integrated into an AC using R32, which is now referred to as an advanced injection-assisted air-conditioner (IAC). Through an experimental and theoretical study, an optimal injection duration of 8 s is attained for maximizing the refrigeration potential of the IAC. Furthermore, in an entire day–night cycle, both the cooling capacity and energy efficiency ratio (EER) of the IAC within the two-phase injection cycle are enhanced by 25% and 32%, respectively, compared with those of a noninjection-assisted AC. Moreover, two-phase injection offers the highest exergetic efficiency, approximately 50% or more in the refrigeration cycle, exhibiting remarkable thermodynamic performance of the IAC. In addition, compared to the conventional AC using R410A, the IAC using R32 within a two-phase injection cycle demonstrates reasonable payback performance and substantial reduction in carbon dioxide and sulfur dioxide emissions in the refrigeration cycle.

  16. Candidates to replace R-12 as a radiator gas in Cherenkov detectors

    Science.gov (United States)

    Harvey, Allan H.; Paulechka, Eugene; Egan, Patrick F.

    2018-06-01

    Dichlorodifluoromethane (R-12) has been widely used as a radiator gas in pressure threshold Cherenkov detectors for high-energy particle physics. However, that compound is becoming unavailable due to the Montreal Protocol. To find a replacement with suitably high refractive index, we use a combination of theory and experiment to examine the polarizability and refractivity of several non-ozone-depleting compounds. Our measurements show that the fourth-generation refrigerants R-1234yf (2,3,3,3-tetrafluoropropene) and R-1234ze(E) (trans-1,3,3,3-tetrafluoropropene) have sufficient refractivity to replace R-12 in this application. If the slight flammability of these compounds is a problem, two nonflammable alternatives are R-218 (octafluoropropane), which has a high Global Warming Potential, and R-13I1 (trifluoroiodomethane), which has low Ozone Depletion Potential and Global Warming Potential but may not be sufficiently inert.

  17. Computer model of the refrigeration system of an ice rink

    Energy Technology Data Exchange (ETDEWEB)

    Teyssedou, G.; Zmeureanu, R. [Concordia Univ., Centre for Building Studies, Montreal, PQ (Canada). Dept. of Building, Civil and Environmental Engineering; Giguere, D. [Natural Resources Canada, Varennes, PQ (Canada). CANMET Energy Technology Centre

    2008-07-01

    This paper presented a refrigeration system model of an existing ice rink using a component approach. The chillers, the ice-concrete slab and the controller were the 3 main components used in the simulations which were performed using both open and closed loop systems. The simulated ice rink refrigeration system was based on measurements taken in an existing indoor ice rink located in Montreal, Quebec. Measurements of the refrigeration system included electricity demand; heat flux on the ice sheet; exterior air temperature; ice temperature; return brine temperature; brine temperature at the pump; brine temperature at both evaporator exits; and refrigerant temperature and pressure at the expansion and condenser valve exits. Simulation results and measurements were found to be in good agreement. A computer model of the refrigeration system was developed using the TRNSYS 16 program. The refrigeration system was composed of 2 chillers using refrigerant R-22. The impact of heat recovery from the condensers on the energy demand for sanitary water heating was also estimated. The potential reduction of equivalent carbon dioxide emissions was calculated using the total equivalent warming impact (TEWI) criterion in an effort to estimate the refrigeration impact on global warming. 12 refs., 4 tabs., 12 figs.

  18. Effects of clove oil-phospholipid mixtures on rheology of gum tragacanth - possible application for surfactant action on mucus gel simulants.

    Science.gov (United States)

    Banerjee, R; Puniyani, R R

    2000-01-01

    The present study evaluates the effectiveness of specialised biomaterials consisting of clove oil- phospholipid mixtures as possible substitute surfactants in diseases of altered mucus viscosity by studying their effect on the viscosity of mucus gel simulants in vitro. Test surfactants consisting of phospholipid-clove oil mixtures in the ratio of 1 part of oil to 9 parts of phospholipid were prepared. The phospholipids used were dipalmitoyl phosphatidylcholine (PC), phosphatidylethanolamine (PE) and phosphatidylglycerol (PG) and binary mixtures of PC: PE and PC: PG in the ratio of 2 parts of PC to 3 parts of PE or PG. The effects of the phospholipid-clove oil mixtures on the viscosity of mucus gel simulant (MGS: a polymeric gel consisting predominantly of gum tragacanth and simulating respiratory mucus), was studied by application of steady shear rates ranging from 0.512 to 51.2/s in a concentric cylinder viscometer at 37 degrees C. The change in MGS viscosity, after incubation with surfactants, was found to have a non-Newtonian character and to follow the power law model with R2 values >0.8. The addition of clove oil-phospholipid mixtures caused a decrease in the MGS viscosity when compared with the effect of the phospholipid alone at low shear rates in case of PC, PG and PCPG. The combination of PC : PG with clove oil caused ratios of change in MGS viscosity < 1 i.e., caused a decrease in the MGS viscosity. PC: PG with clove oil was capable of lowering MGS viscosity and should be further researched as possible therapies for diseases of altered mucus rheology.

  19. Experimental investigation of R-134a and R-600a refrigerant blend ...

    African Journals Online (AJOL)

    GWP) ≤ 150 according to the European Union protocol, alongside other properties, which no single refrigerant has met as at today. This study focused on blending of existing refrigerants towards obtaining blends with GWP ≤ 150.

  20. Theoretical study on a novel dual-nozzle ejector enhanced refrigeration cycle for household refrigerator-freezers

    International Nuclear Information System (INIS)

    Zhou, Mengliu; Wang, Xiao; Yu, Jianlin

    2013-01-01

    Highlights: • A novel dual-nozzle ejector enhanced refrigeration cycle is proposed. • The novel cycle is evaluated by using the developed mathematical model. • The results show the performances of the novel cycle could be significantly improved. • The novel cycle shows its promise in household refrigerator-freezers applications. - Abstract: In this study, a novel dual-nozzle ejector enhanced refrigeration cycle is presented for dual evaporator household refrigerator-freezers. The proposed ejector equipped with two nozzles can efficiently recover the expansion work from cycle throttling processes and enhance cycle performances. The performances of the novel cycle are evaluated by using the developed mathematical model, and then compared with that of the conventional ejector enhanced refrigeration cycle and basic vapor-compression refrigeration cycle. The simulation results show that for the given operating conditions, the coefficient of performance (COP) of the novel cycle using refrigerant R134a is improved by 22.9–50.8% compared with that of the basic vapor-compression refrigeration cycle, and the COP improvement is 10.5–30.8% larger than that of the conventional ejector enhanced refrigeration cycle. The further simulation results of the novel cycle using refrigerant R600a indicate that the cycle COP and volumetric refrigeration capacity could be significantly improved

  1. Performance analysis of the electric vehicle air conditioner by replacing hydrocarbon refrigerant

    Science.gov (United States)

    Santoso, Budi; Tjahjana, D. D. D. P.

    2017-01-01

    The thermal comfort in passenger cabins needs an automotive air-conditioning system. The electric vehicle air conditioner system is driven by an electric compressor which includes a compressor and an electric motor. Almost air-conditioning system uses CFC-12, CFC-22 and HFC-134a as refrigerant. However, CFC-12 and CFC-22 will damage the ozone layer. The extreme huge global warming potentials (GWP) values of CFC-12, CFC-22, and HFC-134a represent the serious greenhouse effect of Earth. This article shows new experimental measurements and analysis by using a mixture of HC-134 to replace HFC-134a. The result is a refrigerating effect, the coefficient of performance and energy factor increase along with cooling capacity, both for HFC-134a and HC-134. The refrigerating effect of HC-134 is almost twice higher than HFC-134a. The coefficient of performance value of HC-134 is also 36.42% greater than HFC-134a. Then, the energy factor value of HC-134 is 3.78% greater than HFC-134a.

  2. Reassessment of forced convection heat transfer correlations for refrigerant-12

    International Nuclear Information System (INIS)

    Celata, G.P.; Cuomo, M.; D'Annibale, F.; Farello, G.E.; Setaro, T.

    1986-01-01

    In the frame of a Refrigerant-12 experiment on postulated accidental transients in Pressurized Water Reactors under way at Heat Transfer Laboratory (ENEA Casaccia Research Center), an assessment of the main correlation available in scientific literature, for the different heat transfer regions encountered when a liquid is boiled in a confined heated channel, has been performed. Considering a vertical tube uniformly heated over its length with CHF at the exit, the following heat transfer regimes may be individuated: convective heat transfer to liquid, subcooled boiling, saturated nucleate boiling, forced convective heat transfer through liquid film (annular flow regime) and thermal crisis. From the comparison of computed values with an original ENEA dataset, the best correlations in predicting Refrigerant-12 data have been individuated. In a few cases, though preserving the original structure of the correlations, mainly developed for water, it was necessary to adjust some coefficients by means of best-fit procedures through our experimental data. The work has been performed in the frame of the ENEA Thermal Reactor Department Safety Research Project

  3. Simulation of absorption refrigeration system for automobile application

    Directory of Open Access Journals (Sweden)

    Ramanathan Anand

    2008-01-01

    Full Text Available An automotive air-conditioning system based on absorption refrigeration cycle has been simulated. This waste heat driven vapor absorption refrigeration system is one alternate to the currently used vapour compression refrigeration system for automotive air-conditioning. Performance analysis of vapor absorption refrigeration system has been done by developing a steady-state simulation model to find the limitation of the proposed system. The water-lithium bromide pair is used as a working mixture for its favorable thermodynamic and transport properties compared to the conventional refrigerants utilized in vapor compression refrigeration applications. The pump power required for the proposed vapor absorption refrigeration system was found lesser than the power required to operate the compressor used in the conventional vapor compression refrigeration system. A possible arrangement of the absorption system for automobile application is proposed.

  4. The experimental investigation of refrigerant distribution and leaking characteristics of R290 in split type household air conditioner

    International Nuclear Information System (INIS)

    Tang, Weier; He, Guogeng; Cai, Dehua; Zhu, Yihao; Zhang, Aoni; Tian, Qiqi

    2017-01-01

    Highlights: • A new quasi-liquid nitrogen method (QLNM) was proposed and firstly applied in experiments. • The R290 distribution was investigated by QLNM and the results proved the validation. • A solenoid valve was proposed to install near the capillary in STHAC in order to reduce risk factor. • R290 leaking rate was firstly measured by QLNM before and after the installation a solenoid valve. - Abstract: As a high-profile replacement for R22 split type household air conditioner (STHAC), R290 has several advantages in terms of thermodynamic properties, environmental characteristics, and cost. However, the obvious shortcoming of R290 is its flammability, which has a potential fire risk to the building. At present, the most important measure to ensure the safety of a R290 STHAC is to limit the refrigerant charge by domestic and international standards. But in fact, when the leakage of R290 occur from a STHAC, the distribution of R290 in STHAC, and the leaking rate also will seriously affect the safety of an R290 STHAC. In this study, a new quasi-liquid nitrogen method (QLNM) has been proposed in order to investigate the refrigerant distribution in R290 STHACs and the leaking rate under various conditions, and the experiments have been conducted. The experimental results of distribution proved the validation of the QLNM and showed that a large portion of the refrigerant distributed in the condenser when the air conditioner is on running stage and the refrigerant will migrate from the condenser to the evaporator when the air conditioner is on closed stage. Based on this, the installation of a solenoid valve near the capillary has been proposed. The comparison of experimental results of R290 leaking rate before and after the installation of a solenoid valve showed it will obviously reduce the leaking rate and thereby improve the safety of the R290 STHACs.

  5. Performance Analysis of Multipurpose Refrigeration System (MRS on Fishing Vessel

    Directory of Open Access Journals (Sweden)

    Ust Y.

    2016-04-01

    Full Text Available The use of efficient refrigerator/freezers helps considerably to reduce the amount of the emitted greenhouse gas. A two-circuit refrigerator-freezer cycle (RF reveals a higher energy saving potential than a conventional cycle with a single loop of serial evaporators, owing to pressure drop in each evaporator during refrigeration operation and low compression ratio. Therefore, several industrial applications and fish storage systems have been utilized by using multipurpose refrigeration cycle. That is why a theoretical performance analysis based on the exergetic performance coefficient, coefficient of performance (COP, exergy efficiency and exergy destruction ratio criteria, has been carried out for a multipurpose refrigeration system by using different refrigerants in serial and parallel operation conditions. The exergetic performance coefficient criterion is defined as the ratio of exergy output to the total exergy destruction rate (or loss rate of availability. According to the results of the study, the refrigerant R32 shows the best performance in terms of exergetic performance coefficient, COP, exergy efficiency, and exergy destruction ratio from among the other refrigerants (R1234yf, R1234ze, R404A, R407C, R410A, R143A and R502. The effects of the condenser, freezer-evaporator and refrigerator-evaporator temperatures on the exergetic performance coefficient, COP, exergy efficiency and exergy destruction ratios have been fully analyzed for the refrigerant R32.

  6. Two-phase flow in refrigeration systems

    CERN Document Server

    Gu, Junjie; Gan, Zhongxue

    2013-01-01

    Two-Phase Flow in Refrigeration Systems presents recent developments from the authors' extensive research programs on two-phase flow in refrigeration systems. This book covers advanced mass and heat transfer and vapor compression refrigeration systems and shows how the performance of an automotive air-conditioning system is affected through results obtained experimentally and theoretically, specifically with consideration of two-phase flow and oil concentration. The book is ideal for university postgraduate students as a textbook, researchers and professors as an academic reference book, and b

  7. Quality control of mixtures consisting of engine oil and rapeseed oil by means of online oil sensors; Qualitaetsueberwachung von Motoroel-Rapsoelmischungen mit Online-Oelsensoren. Labortests

    Energy Technology Data Exchange (ETDEWEB)

    Thuneke, Klaus; Schreiber, Katja [Technologie- und Foerderzentrum, Straubing (Germany)

    2013-10-01

    It was the goal of the work to investigate interactions between motor oils and rapeseed oil fuel and to test oil sensors for monitoring the quality of aged mixtures of motor oil and rapeseed oil. At first oil samples were aged in the laboratory, whereby motor oil type, share of rapeseed oil and aeration was varied. Depending on type of engine oil different ageing effects were noticed. Higher shares of rapeseed and aeration stimulate increase of viscosity and acid value. In a further step online oil sensors were tested in both, a model of a lubrication system and a test engine. The signals of the sensors plausibly described the oil ageing process by the indicators dynamic or acoustic viscosity, permittivity number, specific electric conductivity. In particular viscosity and permittivity are suitable for showing changes in different motor oil rapeseed oil mixtures during oil ageing. However, for a reliable control system detecting critical rapeseed oil enrichment in the motor oil onboard, further work has to be done. (orig.)

  8. EXPERIMENTAL STUDY OF PALM OIL MILL EFFLUENT AND OIL PALM FROND WASTE MIXTURE AS AN ALTERNATIVE BIOMASS FUEL

    Directory of Open Access Journals (Sweden)

    S. HASSAN, L. S. KEE

    2013-12-01

    Full Text Available Palm oil mill effluent (POME sludge generated from palm oil mill industry and oil palm frond (OPF from oil palm plantation are considered biomass wastes that can be fully utilized as a renewable energy sources. In this study, an attempt has been made to convert these residues into solid biomass fuel. The study was conducted by developing experimental testing on the POME and OPF mixture. The performance of each sample with different weight percentage was investigated using standard tests. The biomass mixture was converted into compressed form of briquette through a simple process. The properties of the briquettes were observed and compared at different weight percentage following standard testing methods included ultimate and proximate analyses, burning characteristics, dimensional stability and crack analysis. Experimental results showed that POME sludge and OPF mixture is feasible as an alternative biomass fuel, with briquette of 90:10 POME sludge to OPF ratio has a good combination of properties as an overall.

  9. Prediction of thermodynamic properties of refrigerants using data mining

    International Nuclear Information System (INIS)

    Kuecueksille, Ecir Ugur; Selbas, Resat; Sencan, Arzu

    2011-01-01

    The analysis of vapor compression refrigeration systems requires the availability of simple and efficient mathematical formulations for the determination of thermodynamic properties of refrigerants. The aim of this study is to determine thermodynamic properties as enthalpy, entropy and specific volume of alternative refrigerants using data mining method. Alternative refrigerants used in the study are R134a, R404a, R407c and R410a. The results obtained from data mining have been compared to actual data from the literature. The study shows that the data mining methodology is successfully applicable to determine enthalpy, entropy and specific volume values for any temperature and pressure of refrigerants. Therefore, computation time reduces and simulation of vapor compression refrigeration systems is fairly facilitated.

  10. Local heat transfer coefficients during boiling of R22 and R407C in horizontal smooth and microfin tubes; Coefficients d'echange locaux au cours de l'ebullition du R22 et du R407C dans des tubes horizontaux, lisse ou micro-ailete

    Energy Technology Data Exchange (ETDEWEB)

    Lallemand, M; Branescu, C; Haberschill, P [Centre de Thermique, INSA-CNRS, UMR 5008, Villeurbanne (France)

    2001-07-01

    The purpose of this study is to experimentally investigate forced convective boiling. The heat transfer coefficients of pure refrigerant R22 and non azeotropic refrigerant mixture R407C were measured in both a smooth tube and a microfin tube. The tests have been carried out with a uniform heat flux all along the tube length. The refrigerant mass flux was varied from 100 to 300 kg m{sup -2} s{sup -1} and heat fluxes from 10 to 30 kW m{sup -2}. Local heat transfer coefficient depend strongly on heat flux at a low quality and on mass fluxes at a high quality. When compared to smooth tube, the microfin tubes exhibit a significant heat transfer enhancement, up to 180%. In comparison to R22, the R407C heat transfer coefficients of smooth and microfin tubes are 15 to 35% lower, respectively. The best heat transfer enhancement is obtained at low heat flux and mass flow rate. (Author)

  11. Investigation of pressure drop in capillary tube for mixed refrigerant Joule-Thomson cryocooler

    International Nuclear Information System (INIS)

    Ardhapurkar, P. M.; Sridharan, Arunkumar; Atrey, M. D.

    2014-01-01

    A capillary tube is commonly used in small capacity refrigeration and air-conditioning systems. It is also a preferred expansion device in mixed refrigerant Joule-Thomson (MR J-T) cryocoolers, since it is inexpensive and simple in configuration. However, the flow inside a capillary tube is complex, since flashing process that occurs in case of refrigeration and air-conditioning systems is metastable. A mixture of refrigerants such as nitrogen, methane, ethane, propane and iso-butane expands below its inversion temperature in the capillary tube of MR J-T cryocooler and reaches cryogenic temperature. The mass flow rate of refrigerant mixture circulating through capillary tube depends on the pressure difference across it. There are many empirical correlations which predict pressure drop across the capillary tube. However, they have not been tested for refrigerant mixtures and for operating conditions of the cryocooler. The present paper assesses the existing empirical correlations for predicting overall pressure drop across the capillary tube for the MR J-T cryocooler. The empirical correlations refer to homogeneous as well as separated flow models. Experiments are carried out to measure the overall pressure drop across the capillary tube for the cooler. Three different compositions of refrigerant mixture are used to study the pressure drop variations. The predicted overall pressure drop across the capillary tube is compared with the experimentally obtained value. The predictions obtained using homogeneous model show better match with the experimental results compared to separated flow models

  12. Alternative refrigerants performance in plate heat condenser for air conditioning; Scambiatori compatti per il condizionamento ambientale

    Energy Technology Data Exchange (ETDEWEB)

    Boccardi, G.; Celata, G.P.; Marchesi Donati, F. [ENEA, Rome (Italy). Inst. of Thermal-Fluid Dynamics; Cumo, M. [Rome Univ. La Sapienza, Rome (Italy). Dept. of Nuclear Engineering and Energy Conversion; Gerosa, A. [Rome Univ. Tor Vergata, Rome (Italy). Dept. of Mechanical Engineering; Zorzin, A. [R and D Alfa Laval Artec Spa Vicenza, Vicenza (Italy)

    1999-12-01

    An experimental campaign on plate heat exchangers, used as evaporators and condenser in domestic refrigeration loops is presented in this paper. The research's purpose is to test the influence of some thermal-hydraulic parameters on the global overall heat transfer coefficient. R134a, R407C, R410A, and R22 are the fluids tested under reference thermal conditions. The experimental tests allows one to withdraw conclusions on the substitution effect on the thermal and global efficiency of the plant. Also, a new method for calculating the thermodynamical mixture parameters is applied to the condensation of mixtures R407C and R410A and its benefit evaluated. The refrigerant loop overall performance and the condenser global heat transfer coefficient are the parameters chosen to enlighten the characteristics of the alternative refrigerants (R134a, R407C, and R410A) with respect to the fluid that they are supposed to substitute (R22). [Italian] Scambiatori a piastre compatti impiegati come evaporatori e condensatori nei circuiti frigoriferi, sono l'oggetto della ricerca presentata in questo articolo. L'efficienza termica di tali componenti e' valutata in condizioni di riferimento commerciali. I refrigeranti utilizzati sono tre fluidi proposti per sostituire l'R22, un Hcfc, attualmente il refrigerante piu' utilizzato nel condizionamento ambientale. Una serie di prove condotte con quest'ultimo fluido consente di studiare gli effetti della sostituzione del fluido di progetto sulle prestazioni sia degli scambiatori, sia piu' in generale, dell'intero circuito frigorifero. In particolare sono state studiate le prestazioni di due coppie di evaporatori e condensatori in termini di coefficiente globale di scambio termico e di Cop dell'impianto. Nel presente lavoro e' inoltre presentato e utilizzato un metodo termodinamico per il calcolo della temperatura di saturazione per le miscele zeotropiche in bifase; uno dei refrigeranti

  13. Ultimate refrigerating conditions, behavior turning and a thermodynamic analysis for absorption–compression hybrid refrigeration cycle

    International Nuclear Information System (INIS)

    Zheng Danxing; Meng Xuelin

    2012-01-01

    Highlights: ► Two novel fundamental concepts of the absorption refrigeration cycle were proposed. ► The interaction mechanism of compressor pressure increasing with other key-parameters was investigated. ► A set of optimal operating condition of hybrid refrigeration cycle was found. ► A simulation and investigation for R134a-DMF hybrid refrigeration cycle was performed. - Abstract: The absorption–compression hybrid refrigeration cycle has been considered as an effective approach to reduce the mechanical work consumption by using low-grade heat, such as solar energy. This work aims at studying the thermodynamic mechanism of the hybrid refrigeration cycle. Two fundamental concepts have been proposed, which are the ultimate refrigerating temperature (or the ultimate temperature lift) and the behavior turning. On the basis of that, the interaction mechanism of compressor pressure increasing with other key-parameters and the impact of compressor pressure increasing on the cycle performance have been investigated. The key-parameters include the concentration difference, the circulation ratio of working fluid, etc. The work points out that the hybrid refrigeration cycle performance varies with the change of compressor outlet pressure and depends on which one achieves dominance in the hybrid refrigeration cycle, the absorption sub-system or the compression sub-system. The behavior turning point during parameters changing corresponds to a maximum value of the heat powered coefficient of performance. In this case, the hybrid refrigeration cycle performance is optimal because the low-grade heat utilization is the most effective. In addition, to validate the theoretical analysis, a solar hybrid refrigeration cycle with R134a–DMF as working pair was simulated. The Peng–Robinson equation of state was adopted to calculate thermophysical properties when the reliability assessment of the prediction models on the available literature data of R134a–DMF system had been

  14. Combined treatment of Thymus vulgaris L., Rosmarinus officinalis L. and Myrtus communis L. essential oils against Salmonella typhimurium: Optimization of antibacterial activity by mixture design methodology.

    Science.gov (United States)

    Fadil, Mouhcine; Fikri-Benbrahim, Kawtar; Rachiq, Saad; Ihssane, Bouchaib; Lebrazi, Sara; Chraibi, Marwa; Haloui, Taoufik; Farah, Abdellah

    2018-05-01

    To increase the sensibility of Salmonella typhimurium strain, a mixture of Thymus vulgaris L. (T. vulgaris L.), Rosmarinus officinalis L. (R. officinalis L.) and Myrtus communis L. (M. communis L.) essential oils (EOs) was used in combined treatment by experimental design methodology (mixture design). The chemical composition of EOs was firstly identified by GC and GC/MS and their antibacterial activity was evaluated. The results of this first step have shown that thymol and borneol were the major compounds in T. vulgaris and M. communis L. EOs, respectively, while 1,8-cineole and α-pinene were found as major compounds in R. officinalis L. The same results have shown a strong antibacterial activity of T. vulgaris L. EO followed by an important power of M. communis L. EO against a moderate activity of R. officinalis L. EO. Besides, 1/20 (v/v) was the concentration giving a strain response classified as sensitive. From this concentration, the mixture design was performed and analyzed. The optimization of mixtures antibacterial activities has highlighted the synergistic effect between T. vulgaris L. and M. communis L. essential oils. A formulation comprising 55% of T. vulgaris L. and 45% of M. communis L. essential oils, respectively, can be considered for the increase of Salmonella typhimurium sensibility. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Prediction of thermophysical properties of mixed refrigerants using artificial neural network

    International Nuclear Information System (INIS)

    Sencan, Arzu; Koese, Ismail Ilke; Selbas, Resat

    2011-01-01

    The determination of thermophysical properties of the refrigerants is very important for thermodynamic analysis of vapor compression refrigeration systems. In this paper, an artificial neural network (ANN) is proposed to determine properties as heat conduction coefficient, dynamic viscosity, kinematic viscosity, thermal diffusivity, density, specific heat capacity of refrigerants. Five alternative refrigerants are considered: R413A, R417A, R422A, R422D and R423A. The training and validation were performed with good accuracy. The thermophysical properties of the refrigerants are formulated using artificial neural network (ANN) methodology. Liquid and vapor thermophysical properties of refrigerants with new formulation obtained from ANN can be easily estimated. The method proposed offers more flexibility and therefore thermodynamic analysis of vapor compression refrigeration systems is fairly simplified.

  16. Theoretical research on the performance of the transcritical ejector refrigeration cycle with various refrigerants

    International Nuclear Information System (INIS)

    Wang, F.; Li, D.Y.; Zhou, Y.

    2015-01-01

    The transcritical ejector refrigeration cycle (TERC), which has shown an attractive alternative to the ejector refrigeration systems, can better match large variable-temperature heat sources and yields higher COP. In this paper, in order to find a proper working fluid for the TERC, the performance of the TERC with CO_2 and various working fluids with low critical temperatures including R1270, R32, R143a, R125 and R115 are studied and compared. A thermodynamic model for ejector is set up to simulate the ejector by introducing the real properties of refrigerants. The results indicate that R1270 has the highest COP at the same heat source condition and medium working pressures, and is one of environment-friendly working fluids, hence R1270 is the most proper one. The COP of the transcritical cycle is higher than that of the subcritical cycle, and The effective performance coefficient COP_m of the transcritical cycle is also better. When the heater outlet temperature is increased, its system COP_m improves, but its system COP almost does not change. - Highlights: • A thermodynamic model is used to simulate the ejector with real properties. • The performance of the TERC with various refrigerants is compared. • The environment-friendly working fluid of R1270 shows the most proper one. • The COP of the transcritical cycle is higher than that of the subcritical cycle.

  17. Microphase Separation in Oil-Water Mixtures Containing Hydrophilic and Hydrophobic Ions

    NARCIS (Netherlands)

    Tasios, Nikos; Samin, Sela; van Roij, Rene; Dijkstra, Marjolein

    2017-01-01

    We develop a lattice-based Monte Carlo simulation method for charged mixtures capable of treating dielectric heterogeneities. Using this method, we study oil-water mixtures containing an antagonistic salt, with hydrophilic cations and hydrophobic anions. Our simulations reveal several phases with a

  18. Catalytic hydrodeoxygenation and hydrocracking of Alcell (R) lignin in alcohol/formic acid mixtures using a Ru/C catalyst

    NARCIS (Netherlands)

    Kloekhorst, Arjan; Shen, Yu; Yie, Yao; Fang, Ma; Heeres, Hero Jan

    The catalytic conversion of Alcell (R) lignin in iso-propanol/formic acid mixtures (1: 1 mass ratio) was explored in a batch set-up using Ru/C as the catalyst (673 K, 4 h, 28% mass lignin intake on solvent). Lignin oils were obtained in good yields (71% mass yields on lignin input) and shown to

  19. Optimization of an Indirect Enzymatic Method for the Simultaneous Analysis of 3-MCPD, 2-MCPD, and Glycidyl Esters in Edible Oils.

    Science.gov (United States)

    Koyama, Kazuo; Miyazaki, Kinuko; Abe, Kousuke; Ikuta, Keiich; Egawa, Yoshitsugu; Kitta, Tadashi; Kido, Hirotsugu; Sano, Takashi; Takahashi, Yukinari; Nezu, Toru; Nohara, Hidenori; Miyashita, Takashi; Yada, Hiroshi; Yamazaki, Kumiko; Watanabe, Yomi

    2015-01-01

    We developed a novel, indirect enzymatic method for the analysis of fatty acid esters of 3-monochloro-1,2-propanediol (3-MCPD), 2-monochloro-1,3-propanediol (2-MCPD), and glycidol (Gly) in edible oils and fats. Using this method, the ester analytes were rapidly cleavaged by Candida rugosa lipase at room temperature for 0.5 h. As a result of the simultaneous hydrolysis and bromination steps, 3-MCPD esters, 2-MCPD esters, and glycidyl esters were converted to free 3-MCPD, 2-MCPD, and 3-monobromo-1,2-propanediol (3-MBPD), respectively. After the addition of internal standards, the mixtures were washed with hexane, derivatized with phenylboronic acid, and analyzed by gas chromatography-mass spectrometer (GC-MS). The analytical method was evaluated in preliminary and feasibility studies performed by 13 laboratories. The preliminary study from 4 laboratories showed the reproducibility (RSD R ) of 3-MCPD and 2-MCPD in extra virgin olive (EVO) oil, semi-solid palm oil, and solid palm oil. However, the RSDR and recoveries of Gly in the palm oil samples were not satisfactory. The Gly content of refrigerated palm oil samples decreased whereas the samples at room temperature were stable for three months, and this may be due to the depletion of Gly during cold storage. The feasibility studies performed by all 13 laboratories were conducted based on modifications of the shaking conditions for ester cleavage, the conditions of Gly bromination, and the removal of gel formed by residual lipase. Satisfactory RSDR were obtained for EVO oil samples spiked with standard esters (4.4% for 3-MCPD, 11.2% for 2-MCPD, and 6.6% for Gly).

  20. Modifications to JLab 12 GeV Refrigerator and Wide Range Mix Mode Performance Testing Results

    Science.gov (United States)

    Knudsen, P.; Ganni, V.; Hasan, N.; Dixon, K.; Norton, R.; Creel, J.

    2017-02-01

    Analysis of data obtained during the spring 2013 commissioning of the new 4.5 K refrigeration system at Jefferson Lab (JLab) for the 12 GeV upgrade indicated a wide capacity range with good efficiency and minimal operator interaction. Testing also showed that the refrigerator required higher liquid nitrogen (LN) consumption for its pre-cooler than anticipated by the design. This does not affect the capacity of the refrigerator, but it does result in an increased LN utility cost. During the summer of 2015 the modifications were implemented by the cold box manufacturer, according to a design similar to the JLab 12 GeV cold box specification. Subsequently, JLab recommissioned the cold box and performed extensive performance testing, ranging from 20% to 100% of the design maximum capacity, and in various modes of operation, ranging from pure refrigeration, pure liquefaction, half-and-half mix mode and at selected design modes using the Floating Pressure - Ganni Cycle. The testing demonstrated that the refrigerator system has a good and fairly constant performance over a wide capacity range and different modes of operation. It also demonstrated the modifications resulted in a LN consumption that met the design for the pure refrigeration mode (which is the most demanding) and was lower than the design for the nominal and maximum capacity modes. In addition, a pulsed-load test, similar to what is expected for cryogenic systems supporting fusion experiments, was conducted to observe the response using the Floating Pressure - Ganni Cycle, which was stable and robust. This paper will discuss the results and analysis of this testing pertaining to the LN consumption, the system efficiency over a wide range of capacity and different modes and the behaviour of the system to a pulsed load.

  1. Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC/R), AFSC 3E1X1. OSSN 2368

    National Research Council Canada - National Science Library

    1999-01-01

    Survey Coverage: The Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC/R) career ladder, AFSC 3E1X1, was surveyed to gather data needed to guide the development and evaluation of training...

  2. ENZYMATIC BIODIESEL SYNTHESIS FROM ACID OIL USING A LIPASE MIXTURE

    Directory of Open Access Journals (Sweden)

    Kelly C. N. R. Pedro

    Full Text Available The conventional biodiesel production process has some disadvantages. It is necessary to use refined vegetable oils with low free fatty acids (FFAs content. An alternative route is to use low-cost acid oils in an enzymatic process. The use of lipases allows simultaneous esterification of FFAs and transesterification of triglycerides present in raw material forming alkyl esters. The aim of this work was to study the production of biodiesel using soybean oils with different acid contents (Acid Value of 8.5, 50, 90 and ethanol catalyzed by commercial immobilized lipases (Novozym 435, Lipozyme RM IM and Lipozyme TL IM. A significant decrease of acid value was observed mainly with Novozym 435 and Lipozyme RM IM. The use of a mixture of two immobilized lipases was also investigated to decrease catalyst cost and increase the amount of ester produced. The three commercial immobilized lipases were mixed in a dual system and tested for biodiesel synthesis from acid oil (AV of 8.5, 50 and 90. A positive synergistic effect occurred mainly for Lipozyme TL IM (1,3-specific lipase and Novozym 435 (non-specific lipase blend. The ester content doubled when this lipase mixture was used in ethanolysis of acid oil with AV of 90.

  3. Eco-Friendly Superwetting Material for Highly Effective Separations of Oil/Water Mixtures and Oil-in-Water Emulsions.

    Science.gov (United States)

    Wang, Chih-Feng; Yang, Sheng-Yi; Kuo, Shiao-Wei

    2017-02-20

    Because the treatment of oily wastewater, generated from many industrial processes, has become an increasing environmental concern, the search continues for simple, inexpensive, eco-friendly, and readily scalable processes for fabricating novel materials capable of effective oil/water separation. In this study we prepared an eco-friendly superhydrophilic and underwater superoleophobic polyvinylpyrrolidone (PVP)-modified cotton that mediated extremely efficient separations of mixtures of oil/water and oil/corrosive solutions. This PVP-modified cotton exhibited excellent antifouling properties and could be used to separate oil/water mixtures continuously for up to 20 h. Moreover, the compressed PVP-modified cotton could separate both surfactant-free and -stabilized oil-in-water emulsions with fluxes of up to 23,500 L m -2 h -1 bar -1 -a level one to two orders of magnitude higher than that possible when using traditional ultrafiltration membranes having similar rejection properties. The high performance of our PVP-modified cotton and its green, low-energy, cost-effective preparation suggest its great potential for practical applications.

  4. An Evaluation of the Environmental Impact of Different Commercial Supermarket Refrigeration Systems Using Low Global Warming Potential Refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Beshr, Mohamed [University of Maryland, College Park; Aute, Vikrant [University of Maryland, College Park; Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Radermacher, Reinhard [University of Maryland, College Park

    2014-01-01

    Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system s Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCP of different air-conditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.

  5. Efficiency analysis of alternative refrigerants for ejector cooling cycles

    International Nuclear Information System (INIS)

    Gil, Bartosz; Kasperski, Jacek

    2015-01-01

    Highlights: • Advantages of using alternative refrigerants as ejector refrigerants were presumed. • Computer software basing on theoretical model of Huang et al. (1999) was prepared. • Optimal temperature range of primary vapor for each working fluid was calculated. - Abstract: Computer software, basing on the theoretical model of Huang et al. with thermodynamic properties of selected refrigerants, was prepared. Investigation was focused on alternative refrigerants that belong to two groups of substances: common solvents (acetone, benzene, cyclopentane, cyclohexane and toluene) and non-flammable synthetic refrigerants applied in Organic Rankine Cycle (ORC) (R236ea, R236fa, R245ca, R245fa, R365mfc and RC318). Refrigerants were selected to detect a possibility to use them in ejector cooling system powered by a high-temperature heat source. A series of calculations were carried out for the generator temperature between 70 and 200 °C, with assumed temperatures of evaporation 10 °C and condensation 40 °C. Investigation revealed that there is no single refrigerant that ensures efficient operation of the system in the investigated temperature range of primary vapor. Each substance has its own maximum entrainment ratio and COP at its individual temperature of the optimum. The use of non-flammable synthetic refrigerants allows obtaining higher COP in the low primary vapor temperature range. R236fa was the most beneficial among the non-flammable synthetic refrigerants tested. The use of organic solvents can be justified only for high values of motive steam temperature. Among the solvents, the highest values of entrainment ratio and COP throughout the range of motive temperature were noted for cyclopentane. Toluene was found to be an unattractive refrigerant from the ejector cooling point of view

  6. Cytotoxic and antibacterial activity of the mixture of olive oil and lime cream in vitro conditions.

    Science.gov (United States)

    Sumer, Zeynep; Yildirim, Gulay; Sumer, Haldun; Yildirim, Sahin

    2013-01-01

    The mixture of olive oil and lime cream has been traditionally used to treat external burns in the region of Hatay/Antakya and middle Anatolia. Olive oil and lime cream have been employed by many physicians to treat many ailments in the past. A limited number of studies have shown the antibacterial effect of olive oil and that it does not have any toxic effect on the skin. But we did not find any reported studies on the mixture of olive oil and lime cream. The aim of this paper is to investigate the cytotoxic and antibacterial activity of olive oil and lime cream individually or/and in combination in vitro conditions, by using disk-diffusion method and in cell culture. The main purpose in using this mixture is usually to clear burns without a trace. Agar overlay, MTT (Cytotoxicity assay) and antibacterial susceptibility tests were used to investigate the cytotoxic and antibacterial activity of olive oil and lime cream. We found that lime cream has an antibacterial activity but also cytotoxic on the fibroblasts. On the other hand olive oil has limited or no antibacterial effect and it has little or no cytotoxic on the fibroblasts. When we combined lime cream and olive oil, olive oil reduced its cytotoxic impact. These results suggest that mixture of olive oil and lime cream is not cytotoxic and has antimicrobial activity.

  7. Case Study of R-1234yf Refrigerant: Implications for the Framework for Responsible Innovation.

    Science.gov (United States)

    Wodzisz, Rafał

    2015-12-01

    Safety and care for the natural environment are two of the most important values that drive scientific enterprise in twentieth century. Researchers and innovators often develop new technologies aimed at pollution reduction, and therefore satisfy the strive for fulfilment of these values. This work is often incentivized by policy makers. According to EU directive 2006/40/EC on mobile air conditioning since 2013 all newly approved vehicles have to be filled with refrigerant with low global warming potential (GWP). Extensive and expensive research financed by leading car manufacturers led to invention of R-1234yf refrigerant with GWP marketing. Secondly, I examine framework for responsible innovation. In greater detail I discuss the notions of care for future generations and collective responsibility. Thirdly, I apply the offered framework to the case study at hand. Finally, I draw some conclusions which go in two directions: one is to make some suggestions for improving the framework of RI, and the second is to identify missed opportunities for developing truly responsible refrigerant.

  8. Compatibility of refrigerants and lubricants with elastomers. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, G.R.; Seiple, R.H.; Taikum, Orawan

    1994-01-01

    The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. In part I of the program the swell behavior in the test fluids has been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed fro the refrigerant test fluids and 24 hours after removal from the lubricants. Part II of the testing program includes the evaluation of tensile strength, hardness, weight, and dimensional changes after immersion aging in refrigerant/lubricant mixtures of selected elastomer formulations at elevated temperature and pressure.

  9. Substitution of R502 in existing refrigerating, air-conditioning and heat pump systems with refrigerants of low ozone depletion potential in the Federal Republic of Germany; Ersatz von R 502 in bestehenden Kaelte-, Klima- und Waermepumpenanlagen in der Bundesrepublik Deutschland durch Kaeltemittel mit geringerem Ozonabbaupotential

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    The technical basics and the state of engineering for the substitution of R502 in existing refrigeration systems are described and explained. The report contains an overview of the current applications of R502 in the FRG, the presentation and discussion of existing substitutes, the presentation and valuations of research and experiences with the adaptation to alternative refrigerants, the presentation of the required infrastructure and a discussion of the technical feasibility. The conversion of existing systems to refrigerants of lower ozone depletion potential is in conclusion valuated with regard to its technical feasibility, environmental relevance and economic efficiency. (orig.) [Deutsch] Es werden die technischen Grundlagen und der Stand der Technik zum Ersatz von R502 in bestehenden Kaelteanlagen dargestellt und erlaeutert. Der Bericht beinhaltet einen Ueberblick ueber die derzeitige Anwendung von R502 in der BRD, die Vorstellung und Diskussion existierender Ersatzstoffe, die Darstellung und Bewertung der Forschung und Erfahrungen zu Umruestungen auf Ersatzstoffe, die Vorstellung der erforderlichen Infrastruktur und die Diskussion der technischen Durchfuehrbarkeit. Die Umstellung bestehender Anlagen auf Kaeltemittel mit geringerem Ozonabbaupotential wird abschliessend hinsichtlich der technischen Durchfuehrbarkeit, der Umweltrelevanz und der Wirtschaftlichkeit bewertet. (orig.)

  10. Data mining techniques for thermophysical properties of refrigerants

    International Nuclear Information System (INIS)

    Kuecueksille, Ecir Ugur; Selbas, Resat; Sencan, Arzu

    2009-01-01

    This study presents ten modeling techniques within data mining process for the prediction of thermophysical properties of refrigerants (R134a, R404a, R407c and R410a). These are linear regression (LR), multi layer perception (MLP), pace regression (PR), simple linear regression (SLR), sequential minimal optimization (SMO), KStar, additive regression (AR), M5 model tree, decision table (DT), M5'Rules models. Relations depending on temperature and pressure were carried out for the determination of thermophysical properties as the specific heat capacity, viscosity, heat conduction coefficient, density of the refrigerants. Obtained model results for every refrigerant were compared and the best model was investigated. Results indicate that use of derived formulations from these techniques will facilitate design and optimize of heat exchangers which is component of especially vapor compression refrigeration system

  11. Comparison of a R744 cascade refrigeration system with R404A and R22 conventional systems for supermarkets

    International Nuclear Information System (INIS)

    Silva, Alessandro da; Pedone Bandarra Filho, Enio; Pontes Antunes, Arthur Heleno

    2012-01-01

    The present article focuses on the energy efficiency and climate performance of three different systems used in supermarket applications. The refrigeration systems consist of a cascade cycle (CO 2 /HFC-404A) – provide nominal refrigerating capacity – with carbon dioxide for subcritical operation and HFC-404A in the high stage temperature stage (pump circuit for normal refrigeration and direct expansion for deep-freezing), and also HFC-404A and HCFC-22 with direct expansion systems. The cascade system presented a lower refrigerant charge, 47 kg of both fluids, which represents less than a half of the refrigerant charge of the other systems. An important factor is the total GWP in case of leakage, where the impact in the atmosphere of the cascade system operating with CO 2 was much less than the two direct expansion systems.

  12. Estimating animal abundance with N-mixture models using the R-INLA package for R

    KAUST Repository

    Meehan, Timothy D.

    2017-05-03

    Successful management of wildlife populations requires accurate estimates of abundance. Abundance estimates can be confounded by imperfect detection during wildlife surveys. N-mixture models enable quantification of detection probability and often produce abundance estimates that are less biased. The purpose of this study was to demonstrate the use of the R-INLA package to analyze N-mixture models and to compare performance of R-INLA to two other common approaches -- JAGS (via the runjags package), which uses Markov chain Monte Carlo and allows Bayesian inference, and unmarked, which uses Maximum Likelihood and allows frequentist inference. We show that R-INLA is an attractive option for analyzing N-mixture models when (1) familiar model syntax and data format (relative to other R packages) are desired, (2) survey level covariates of detection are not essential, (3) fast computing times are necessary (R-INLA is 10 times faster than unmarked, 300 times faster than JAGS), and (4) Bayesian inference is preferred.

  13. Ammonia-a refrigerant in the past and present, more and more in the future

    International Nuclear Information System (INIS)

    Ciconkov, Risto; Lindborg, Anders

    2000-01-01

    The harmful influence on the global climate of CFCs (R11, R12, R502) and HCFCs (R22) refrigerants causes the depletion of the stratospheric ozone and the greenhouse effect. The international activity for the phase-out of the ozone depletion substances (ODSS) is the Montreal Protocol. The alternative refrigerants on the market are natural working fluids: ammonia, hydrocarbons (HCs), carbon dioxide, water and air. HFCs are for some applications the alternatives for CFC/HCFCs and have no ozone depletion (ODP=O), but the HFCs are greenhouse gases and have GWP and are regulated in the Kyoto Protocol. Ammonia has been in use for more than 125 years. The advantages of ammonia are excellent thermodynamic and heat transport properties, but ammonia is regarded as toxic and flammable. The ammonia refrigerating systems are liable under codes and standards, which shall be followed. With better knowledge and understanding, good practice and right comprehension of people involved in ammonia refrigeration, this refrigerant is a winner. There are many research projects and activities in order to widen the use of ammonia in the applications where CFC/HCFCs were used in the past. Regarding to this trend, it is a paradoxical situation in Macedonia and other developing countries where ammonia systems of cold stores, diaries, breweries and food processing go out of use. (Author)

  14. Energetic analysis of a commercial absorption refrigeration unit using an ammonia-water mixture

    Directory of Open Access Journals (Sweden)

    Josegil Jorge de Araújo

    2017-09-01

    Full Text Available The ROBUR® absorption refrigeration system (ARS, model ACF60, with a capacity of 17.5 kW, is tested, modeled and simulated in the steady state. To simulate the thermal load a heating system with secondary coolant was used, in which a programmable logic controller (PLC kept the inlet temperature EVA at around 285.15 K. The mathematical model used was based on balancing the mass, energy and ammonia concentrations and completed by closing equations such as, Newton's cooling equation. The mathematical model was implemented using the Engineering Equation Solver – EES®. The results obtained after modeling and a numerical permanent simulation are studied using the Duhring diagram. Potential points of internal heat recovery are visualized, and by using graphs of the binary mixture, it is possible to identify the thermodynamic states of all monitored points. The data obtained in the numerical simulation of the ARS was compared with data acquired in the actual tests of the ARS with the ROBUR® apparatus.

  15. Energy and exergy analysis of LPG (liquefied petroleum gas) as a drop in replacement for R134a in domestic refrigerators

    International Nuclear Information System (INIS)

    El-Morsi, Mohamed

    2015-01-01

    This study presents a comparison of energetic and exergetic performance of a vapour compression refrigeration system using pure HC (hydrocarbon) refrigerants. In this study, three different pure HCs propane (R290), butane (R600) and commercial LPG (liquefied petroleum gas) are used in the theoretical analysis. R134a is also used in the analysis as a reference refrigerant. The evaporator temperature ranges from −30 to 0 °C while the condenser ranges from 30 to 50 °C. MATLAB software is used for solving the thermodynamic equations, while the thermo-physical properties are calculated using REFPROP software. The results show that R600 has the highest COP c and exergetic efficiency, while LPG has the lowest. When compared to R134a, the COP c for R134a is higher than that for LPG by 10%. Also, the exergetic efficiency is higher by 5%. However, LPG has the advantage of being not expensive, available in large amounts and zero ozone depletion potential and low global warming potential. - Highlights: • The results show that R600 has the highest COP c & exergy efficiency, and the lowest irreversibility. • LPG has the lowest COP c & exergy efficiency, and the highest irreversibility. • Compared to R134a, LPG has a lower COP c and exergy efficiency by an average of 10% and 5%, respectively

  16. A review of linear compressors for refrigeration

    OpenAIRE

    Liang, Kun

    2017-01-01

    Linear compressor has no crank mechanism compared with conventional reciprocating compressor. This allows higher efficiency, oil-free operation, lower cost and smaller size when linear compressors are used for vapour compression refrigeration (VCR) system. Typically, a linear compressor consists of a linear motor (connected to a piston) and suspension springs, operated at resonant frequency. This paper presents a review of linear compressors for refrigeration system. Different designs and mod...

  17. Investigation of the mixture flow rates of oil-water two-phase flow using the turbine flow meter

    International Nuclear Information System (INIS)

    Li Donghui; Feng Feifei; Wu Yingxiang; Xu Jingyu

    2009-01-01

    In this work, the mixture flow rate of oil-water flows was studied using the turbine flow-meter. The research emphasis focuses on the effect of oil viscosity and input fluids flow rates on the precision of the meter. Experiments were conducted to measure the in-situ mixture flow rate in a horizontal pipe with 0.05m diameter using seven different viscosities of white oil and tap water as liquid phases. Results showed that both oil viscosity and input oil fraction exert a remarkable effect on measured results, especially when the viscosity of oil phase remained in the area of high value. In addition, for metering mixture flow rate using turbine flow-meter, the results are not sensitive to two-phase flow pattern according to the experimental data.

  18. Theoretical analysis of ejector refrigeration system performance under overall modes

    International Nuclear Information System (INIS)

    Chen, Weixiong; Shi, Chaoyin; Zhang, Shuangping; Chen, Huiqiang; Chong, Daotong; Yan, Junjie

    2017-01-01

    Highlights: • Real gas theoretical model is used to get ejector performance at critical/sub-critical modes. • The model has a better accuracy against the experiment results compared to ideal gas model. • The overall performances of two refrigerants are analyzed based on the parameter analysis. - Abstract: The ejector refrigeration integrated in the air-conditioning system is a promising technology, because it could be driven by the low grade energy. In the present study, a theoretical calculation based on the real gas property is put forward to estimate the ejector refrigeration system performance under overall modes (critical/sub-critical modes). The experimental data from literature are applied to validate the proposed model. The findings show that the proposed model has higher accuracy compared to the model using the ideal gas law, especially when the ejector operates at sub-critical mode. Then, the performances of the ejector refrigeration circle using different refrigerants are analyzed. R290 and R134a are selected as typical refrigerants by considering the aspects of COP, environmental impact, safety and economy. Finally, the ejector refrigeration performance is investigated under variable operation conditions with R290 and R134a as refrigerants. The results show that the R290 ejector circle has higher COP under critical mode and could operate at low evaporator temperature. However, the performance would decrease rapidly at high condenser temperature. The performance of R134a ejector circle is the opposite, with relatively lower COP, and higher COP at high condenser temperature compared to R290.

  19. Efficiency improvement of commercial refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Denecke, Julius [NTNU, Trondheim (Norway); Hafner, Armin [SINTEF Energy Research, Trondheim (Norway)

    2011-07-01

    This work presents a historical review of carbon dioxide refrigeration systems. Further a literature survey is carried out to get a status of existing refrigeration technology related to supermarkets. In the next step various energy saving options are stated. A heat recovery model, basing on a R744 booster refrigeration system is established and described. Simplified demand curves for refrigeration, air conditioning and heating will base this model to calculate different heat recovery layouts. Supermarket future trends will be considered and integrated in the calculation. Finally the calculated energy consumptions will be compared with real energy consumptions of selected supermarket refrigeration systems.

  20. Molecular and structural changes induced by essential oils treatments in Vicia faba roots detected by genotoxicity testing.

    Science.gov (United States)

    Sturchio, Elena; Boccia, Priscilla; Zanellato, Miriam; Meconi, Claudia; Donnarumma, Lucia; Mercurio, Giuseppe; Mecozzi, Mauro

    2016-01-01

    Over the last few years, there has been an increased interest in exploiting allelopathy in organic agriculture. The aim of this investigation was to examine the effects of essential oil mixtures in order to establish their allelopathic use in agriculture. Two mixtures of essential oils consisting respectively of tea tree oil (TTO) and clove plus rosemary (C + R) oils were tested. Phytotoxicity and genotoxicity tests on the root meristems of Vicia faba minor were performed. A phytotoxic influence was particularly relevant for C + R mixture, while genotoxicity tests revealed significant results with both C + R oil mixture and TTO. Phenotypic analysis on Vicia faba minor primary roots following C + R oil mixture treatment resulted in callose production, an early symptom attributed to lipid peroxidation. The approach described in this study, based on genotoxicity bioassays, might identify specific DNA damage induced by essential oil treatments. These tests may represent a powerful method to evaluate potential adverse effects of different mixtures of essential oils that might be useful in alternative agriculture. Future studies are focusing on the positive synergism of more complex mixtures of essential oils in order to reduce concentrations of potentially toxic components while at the same time maintaining efficacy in antimicrobial and antifungal management.

  1. Estimation of the minimum Prandtl number for binary gas mixtures formed with light helium and certain heavier gases: Application to thermoacoustic refrigerators

    International Nuclear Information System (INIS)

    Campo, Antonio; Papari, Mohammad M.; Abu-Nada, Eiyad

    2011-01-01

    This paper addresses a detailed procedure for the accurate estimation of low Prandtl numbers of selected binary gas mixtures. In this context, helium (He) is the light primary gas and the heavier secondary gases are nitrogen (N 2 ), oxygen (O 2 ), xenon (Xe), carbon dioxide (CO 2 ), methane (CH 4 ), tetrafluoromethane or carbon tetrafluoride (CF 4 ) and sulfur hexafluoride (SF 6 ). The three thermophysical properties forming the Prandtl number of binary gas mixtures Pr mix are heat capacity at constant pressure C p,mix (thermodynamic property), viscosity η mix (transport property) and thermal conductivity λ mix (transport property), which in general depend on temperature T and molar gas composition w. The precise formulas for the calculation of the trio C p,mix , η mix , and λ mix are gathered from various dependable sources. When the set of computed Pr mix values for the seven binary gas mixtures He + N 2 , He + O 2 , He + Xe, He + CO 2 , He + CH 4 , He + CF 4 , He + SF 6 at atmospheric conditions T = 300 K, p = 1 atm is plotted against the molar gas composition w on the w-domain [0,1], the family of Pr mix (w) curves exhibited distinctive concave shapes. In the curves format, all Pr mix (w) curves initiate with Pr ∼ 0.7 at w = 0 (associated with light primary He). Forthwith, each Pr mix (w) curve descends to a unique minimum and thereafter ascend back to Pr ∼ 0.7 at the terminal point w = 1 (connected to heavier secondary gases). Overall, it was found that among the seven binary gas mixtures tested, the He + Xe gas mixture delivered the absolute minimum Prandtl number Pr mix,min = 0.12 at the optimal molar gas composition w opt = 0.975. - Highlights: →Accurate estimation of low Prandtl numbers for some helium-based binary gas mixtures. →The thermophysical properties of the gases are calculated with precise formulas. →The absolute minimum Prandtl number is delivered by the He + Xe binary gas mixture. →Application to experimental thermoacoustic

  2. Experimental study on a prototype of heat pipe solar water heater using refrigerant R134a as a transfer fluid

    Science.gov (United States)

    Sitepu, T.; Sembiring, J.; Ambarita, H.

    2018-02-01

    A prototype of a solar water heater by using refrigerant as a heat transfer fluid is investigated experimentally. The objective is to explore the characteristics and the performance of the prototype. To make heat transfer from the collector to the heated fluid effectively, refrigerant R134a is used as a transfer. In the experiments, the initial pressure inside the heat pipe is varied. The prototype is exposed to solar irradiation in a location in Medan city for three days of the experiment. Solar collector temperatures, solar radiation, water temperature, and ambient temperature are measured. The efficiency of the system is analyzed. The results show that temperature of the hot water increases as the initial pressure of the working fluid increase. However, the increasing is not linear, and there must exist an optimum initial pressure. For the case with the refrigerant pressure of 110 psi, the maximum hot water temperature and maximum thermal efficiency are 45.36oC and 53.23%, respectively. The main conclusion can be drawn here is that solar water heater by using refrigerant R134a should be operated at initial pressure 110 psi.

  3. Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Vineyard, Edward Allan [ORNL

    2012-01-01

    Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; system performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.

  4. Study of change of refrigerant R{sub 2}2 in chiller units by simulation in EcosimPro; Estudio de cambio de gas refriferante R{sub 2}2 en unidades enfriadoras mediante simulacion en EcosimPro

    Energy Technology Data Exchange (ETDEWEB)

    Prieto, J.; Molina, C.; Olmedo, J.; Gavilan, C. J.

    2014-07-01

    On January 1, 2010 is forbidden to hold any stock of virgin R{sub 2}2 refrigerant and it is also forbidden to use virgin R{sub 2}2 refrigerant for the service and maintenance of equipment under the new European Community Regulation 20137/2000. On January 1, 2015 and stock of R{sub 2}2, even if reclaimed or recycled, will be illegal to hold. In accordance with the European Community regulation, Cofrentes Nuclear Power Plant begins the R{sub 2}2 retrofit. (Author)

  5. mixtools: An R Package for Analyzing Mixture Models

    Directory of Open Access Journals (Sweden)

    Tatiana Benaglia

    2009-10-01

    Full Text Available The mixtools package for R provides a set of functions for analyzing a variety of finite mixture models. These functions include both traditional methods, such as EM algorithms for univariate and multivariate normal mixtures, and newer methods that reflect some recent research in finite mixture models. In the latter category, mixtools provides algorithms for estimating parameters in a wide range of different mixture-of-regression contexts, in multinomial mixtures such as those arising from discretizing continuous multivariate data, in nonparametric situations where the multivariate component densities are completely unspecified, and in semiparametric situations such as a univariate location mixture of symmetric but otherwise unspecified densities. Many of the algorithms of the mixtools package are EM algorithms or are based on EM-like ideas, so this article includes an overview of EM algorithms for finite mixture models.

  6. Situation and perspectives in refrigerating and air-conditioning. The point of view of Elf Atochem; Situation et perspectives en refrigeration et air conditionne. Point de vue d`Elf Atochem

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This paper is a series of transparencies which explains the engagements of Elf Atochem company in the replacement of chlorofluorocarbons (CFCs): development of HFCs, production of FORANE, safety and environmental criteria, main refrigerants and their application in new installations, perspectives in reconversion, replacement of R-22, CFC-12 and R-502 fluids with respect to their applications. (J.S.)

  7. Studies on The Synergistic Effect of Some Irradiated Essential Oils in Some Food Products

    International Nuclear Information System (INIS)

    Hanafy, M.A.A.

    2013-01-01

    Cumin, rosemary and thyme essential oils were gamma irradiated. Then, antibacterial and antioxidant activities were studied to measure the synergistic effect of their essential oils mixtures. 4, 6 and 4 kGy were the recommended doses for cumin, rosemary and thyme, respectively according to antimicrobial activity (agar well-diffusion) against S. typhimurium, S. aureus, B. cereus and E. coli. There were no changes in the physiochemical properties due to irradiation but, some changes occurred in the GC/MS analysis where, the amount of oxygenated compounds increased in cumin and thyme essential oils while, the oxygenated compounds decreased in rosemary essential oil. The mixture made from non-irradiated cumin (C 0 ) and rosemary (R 0 ) essential oils were showed the highest antimicrobial activity against E. coil and B. cereus at 50 μl. Mixtures made from non-irradiated cumin and thyme (T 0 ) essential oils showed the highest antimicrobial activity against B. cereus. Mixtures made form irradiated cumin at dose 4 kGy (C 4 ) and rosemary at dose 6 kGy (R 6 ) essential oils introduced promising antimicrobial activity as well as C 0 XR 0 mixture. Fraction inhibitory concentrations (FIC) were studied against selected four bacterial strains for measuring synergistic activity however, (FIC) represented indifference in all essential oils mixtures but, the C 0 X R 0 mixture against B. cereus (0.375) and E. coli (0.375) was synergy (below 0.5). Furthermore, the FIC shows addition in case of R 0 XT 0 , C 2 XR 6 , C 4 XR 6 and R 6 XT 4 against B. cereus. And in case of C 4 XR 6 against S. typhimurium. Preliminary experiment represented that 0.2, 0.4 and 0.1% were the acceptable odor in sunflower oil supplemented with rosemary, cumin and thyme essential oils, respectively.

  8. Thermodynamic analysis of hydrocarbon refrigerants-based ethylene BOG re-liquefaction system

    Science.gov (United States)

    Beladjine, Boumedienne M.; Ouadha, Ahmed; Addad, Yacine

    2016-09-01

    The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refrigeration cycle operating with a hydrocarbon refrigerant. The hydrocarbon refrigerants considered are propane (R290), butane (R600), isobutane (R600a), and propylene (R1270). A computer program written in FORTRAN is developed to compute parameters for characteristic points of the cycles and the system's performance, which is determined and analyzed using numerical solutions for the refrigerant condensation temperature, temperature in tank, and temperature difference in the cascade condenser. Results show that R600a gives the best performance, followed by (in order) R600, R290, and R1270. Furthermore, it is found that an increase in tank temperature improves system performance but that an increase in refrigerant condensation temperature causes deterioration. In addition, it is found that running the system at a low temperature difference in the cascade condenser is advantageous.

  9. Transesterification of waste vegetable oil under pulse sonication using ethanol, methanol and ethanol–methanol mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Guerra, Edith; Gude, Veera Gnaneswar, E-mail: gude@cee.msstate.edu

    2014-12-15

    Highlights: • Pulse sonication effect on transesterification of waste vegetable oil was studied. • Effects of ethanol, methanol, and alcohol mixtures on FAMEs yield were evaluated. • Effect of ultrasonic intensity, power density, and its output rates were evaluated. • Alcohol mixtures resulted in higher biodiesel yields due to better solubility. - Abstract: This study reports on the effects of direct pulse sonication and the type of alcohol (methanol and ethanol) on the transesterification reaction of waste vegetable oil without any external heating or mechanical mixing. Biodiesel yields and optimum process conditions for the transesterification reaction involving ethanol, methanol, and ethanol–methanol mixtures were evaluated. The effects of ultrasonic power densities (by varying sample volumes), power output rates (in W), and ultrasonic intensities (by varying the reactor size) were studied for transesterification reaction with ethanol, methanol and ethanol–methanol (50%-50%) mixtures. The optimum process conditions for ethanol or methanol based transesterification reaction of waste vegetable oil were determined as: 9:1 alcohol to oil ratio, 1% wt. catalyst amount, 1–2 min reaction time at a power output rate between 75 and 150 W. It was shown that the transesterification reactions using ethanol–methanol mixtures resulted in biodiesel yields as high as >99% at lower power density and ultrasound intensity when compared to ethanol or methanol based transesterification reactions.

  10. Impact of Flax Seed and Canola Oils Mixture Supplementation on The Physiological and Biochemical Changes Induced by Monosodium Glutamate in Rats

    International Nuclear Information System (INIS)

    Anwar, M.M.; Mohamed, N.E.

    2010-01-01

    One of the most important problems in the human health nutrition field is the use of food flavor. Monosodium glutamate is one of the main flavors used as an ingredient in various food products, however it produces physiological and biochemical changes. The main objective of this study is to evaluate the supplementation of flax seed and canola oils mixture against the physiological and biochemical changes induced by monosodium glutamate in rats. In addition to analyses the physical and chemical characteristics of flax seed and canola oil and fatty acids composition by using gas liquid chromatography. The results concerning that unsaturated fatty acids of flax seed oil were oleic (18:1) 22%, linoleic acid (18:2) 30 % and linolenic acid (18:3) 36%. Total unsaturated fatty acids percentage in flaxseed oil was 88% and total saturated fatty acids 12%. The unsaturated fatty acids of canola oil were oleic (18:1) 66%, linoleic acid (18:2) 18% and linolenic acid (18:3) 7%, total unsaturated fatty acids percentage in canola oil was 92% and total saturated fatty acids was 8%. On the other hand, treatment of rats with monosodium glutamate for ten consecutive days led to a decrease in RBCs, Hb, Hct % and increased platelet count with decrease in WBCs and undesirable changes in its differential count. There is also, high significant increase in testicular thiobarbituric acid reactive substances (TBARS) which is accompanied with significant reduction in catalase (CAT) activity, reduced glutathione (GSH) content and serum testosterone level. These disturbances were associated with significant increase in the liver enzymes ALT,AST and ALP and increase in the level of total biluribin and glucose. Also, significant increase in urea, creatinine and uric acid were recorded. The supplementation with mixture of flax seed and canola oils mixture for one month after the injection of monosodium glutamate caused noticeable amelioration in the damage occurred as a result of this flavor. To

  11. Exergy analysis of vapor compression refrigeration cycle with two-stage and intercooler

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Bayram [Mehmet Akif Ersoy University, Bucak Emin Guelmez Vocational School, Bucak, Burdur (Turkey)

    2012-07-15

    In this study, exergy analyses of vapor compression refrigeration cycle with two-stage and intercooler using refrigerants R507, R407c, R404a were carried out. The necessary thermodynamic values for analyses were calculated by Solkane program. The coefficient of performance, exergetic efficiency and total irreversibility rate of the system in the different operating conditions for these refrigerants were investigated. The coefficient of performance, exergetic efficiency and total irreversibility rate for alternative refrigerants were compared. (orig.)

  12. Development of a low-temperature refrigerant on the basis of carbon dioxide; Entwicklung eines Tieftemperaturkaeltemittels auf Basis von Kohlendioxid

    Energy Technology Data Exchange (ETDEWEB)

    Goepfert, Tobias; Hesse, Ullrich [Technische Univ. Dresden (Germany). Bitzer-Stiftungsprofessur fuer Kaelte-, Kryo- und Kompressorentechnik

    2014-07-01

    With the help of known substance properties and derived calculation correlations the mixtures were identified on the basis of R744, which are suitable as a cryogenic refrigerant in the range -50 to -100 degrees Celsius. A prediction and assessment of the suitability of the mixtures is made and the still unknown material properties are shown, which are required for detailed evaluation. [German] Mit Hilfe von bekannten Stoffeigenschaften und abgeleiteten Berechnungskorrelationen wurden Gemische auf der Basis von R744 identifiziert, welche sich als Tieftemperaturkaeltemittel im Bereich von -50 bis -100 Grad Celsius eigenen. Es wird eine Prognose und Abschaetzung der Eignung der Stoffgemische vorgenommen und es werden die noch unbekannten Stoffeigenschaften dargestellt, die zur genauen Bewertung benoetigt werden.

  13. Influence of the nozzle angle on refrigeration performance of a gas wave refrigerator

    Science.gov (United States)

    Liu, P.; Zhu, Y.; Wang, H.; Zhu, C.; Zou, J.; Wu, J.; Hu, D.

    2017-05-01

    A gas wave refrigerator (GWR) is a novel refrigerating device that refrigerates a medium by shock waves and expansion waves generated by gas pressure energy. In a typical GWR, the injection energy losses between the nozzle and the expansion tube are essential factors which influence the refrigeration efficiency. In this study, numerical simulations are used to analyze the underlying mechanism of the injection energy losses. The results of simulations show that the vortex loss, mixing energy loss, and oblique shock wave reflection loss are the main factors contributing to the injection energy losses in the expansion tube. Furthermore, the jet angle of the gas is found to dominate the injection energy losses. Therefore, the optimum jet angle is theoretically calculated based on the velocity triangle method. The value of the optimum jet angle is found to be 4^{circ }, 8^{circ }, and 12^{circ } when the refrigeration efficiency is the first-order, second-order, and third-order maximum value over all working ranges of jet frequency, respectively. Finally, a series of experiments are conducted with the jet angle ranging from -4^{circ } to 12^{circ } at a constant expansion ratio. The results indicate the optimal jet angle obtained by the experiments is in good agreement with the calculated value. The isentropic refrigeration efficiency increased by about 4 % after the jet angle was optimized.

  14. Burn drug made from ozonated vegetable oil mixture with white tumeric and cassava leaves extract

    Directory of Open Access Journals (Sweden)

    Moulydia Farah

    2018-01-01

    Full Text Available This research aims to create a burn treatment performed with ozonation process from a mixture of vegetable oil and added extracts of herbal ingredients. Ozonation on vegetable oils proven to kill bacteria and safe for the body. Ozonated vegetable oil produced from the ozone reactor batch process by doing a variety of extraction mixture to Oleozon® and vegetable oils. Then the results of ozonation is added extracts of herbal ingredients that cassava leaves and white turmeric to increase effectiveness in killing bacteria. Cassava leaves have anti-inflammatory agent, namely Vitamin C. While white turmeric Curcuma zedoaria have substance, which of the two compounds can inhibit and kill bacteria. The quality of ozonated oil (Oleozon® analytically were tested by the method of iodine number, acid number, peroxide number, and FTIR. Ozonation increased the peroxide and acid values for both oils, the increase being higher for mixture of coconut oil and soybean oil. The results of such mixing is then tested in bacteria to determine their effectiveness in killing the bacteria. The best ozonation condition is in an increase of 386,85% acid value, peroxide value about 102,91 meq/kg oil, and decrease in iodine number up to 21%. The result showed that under these conditions, ozonized oil has an antiseptic effect against Staphylococcus aureus. The final results of this study are expected to be a new innovation in the healing of skin wounds caused by burns as an anti-inflammatory that is effective, safe, and environmentally friendly.

  15. Experimental Study on Compression/Absorption High-Temperature Hybrid Heat Pump with Natural Refrigerant Mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Young; Park, Seong Ryong; Baik, Young Jin; Chang, Ki Chang; Ra, Ho Sang; Kim, Min Sung [Korea Institute of Energy Research, Daejeon (Korea, Republic of); Kim, Yong Chan [Korea University, Seoul (Korea, Republic of)

    2011-12-15

    This research concerns the development of a compression/absorption high-temperature hybrid heat pump that uses a natural refrigerant mixture. Heat pumps based on the compression/absorption cycle offer various advantages over conventional heat pumps based on the vapor compression cycle, such as large temperature glide, temperature lift, flexible operating range, and capacity control. In this study, a lab-scale prototype hybrid heat pump was constructed with a two-stage compressor, absorber, desorber, desuperheater, solution heat exchanger, solution pump, liquid/vapor separator, and rectifier as the main components. The hybrid heat pump system operated at 10-kW-class heating capacity producing hot water whose temperature was more than 90 .deg. C when the heat source and sink temperatures were 50 .deg. C. Experiments with various NH{sub 3}/H{sub 2}O mass fractions and compressor/pump circulation ratios were performed on the system. From the study, the system performance was optimized at a specific NH{sub 3} concentration.

  16. Rheology of petrolatum-paraffin oil mixtures : Applications to analogue modelling of geological processes

    NARCIS (Netherlands)

    Duarte, João C.; Schellart, Wouter P.; Cruden, Alexander R.

    2014-01-01

    Paraffins have been widely used in analogue modelling of geological processes. Petrolatum and paraffin oil are commonly used to lubricate model boundaries and to simulate weak layers. In this paper, we present rheological tests of petrolatum, paraffin oil and several homogeneous mixtures of the two.

  17. Energy performance of supermarket refrigeration and air conditioning integrated systems working with natural refrigerants

    International Nuclear Information System (INIS)

    Cecchinato, Luca; Corradi, Marco; Minetto, Silvia

    2012-01-01

    The current trends in commercial refrigeration aim at reducing the synthetic refrigerant charge, either by minimising the internal volume of the circuit or by utilising natural refrigerants, and at energy saving. The energy efficiency of supermarkets can be improved by optimising components design, recovering thermal and refrigerating energy, adopting innovative technology solutions, integrating the HVAC system with medium temperature and low temperature refrigeration plants and, finally, reducing thermal loads on refrigerated cases. This study aims at investigating the performance of different lay-out and technological solutions where only natural refrigerants are used and at finding the potential for improving energy efficiency over the traditional systems in different climates. In the analysis, chillers and heat pumps working with ammonia or propane, medium temperature systems working with ammonia or propane and carbon dioxide as heat transfer fluid or with carbon dioxide as the refrigerant and low temperature systems working with carbon dioxide are considered and benchmarked with a state-of-the-art HFCs based plant. The most efficient investigated solution enables an annual energy saving higher than 15% with respect to the baseline solution for all the considered climates. - Highlights: ► Different natural refrigerants supermarket HVAC and R integrated systems are analysed. ► Some of the proposed solutions offer a significant benefit over the baseline one. ► Up to 18.7% energy saving is achieved in the considered climates. ► The refrigeration unit condensation by the AC chiller offers the poorest results.

  18. Analysis of a combined Rankine-vapour-compression refrigeration cycle

    International Nuclear Information System (INIS)

    Aphornratana, Satha; Sriveerakul, Thanarath

    2010-01-01

    This paper describes a theoretical analysis of a heat-powered refrigeration cycle, a combined Rankine-vapour-compression refrigeration cycle. This refrigeration cycle combines an Organic Rankine Cycle and a vapour-compression cycle. The cycle can be powered by low grade thermal energy as low as 60 deg. C and can produce cooling temperature as low as -10 deg. C. In the analysis, two combined Rankine-vapour-compression refrigeration cycles were investigated: the system with R22 and the system with R134a. Calculated COP values between 0.1 and 0.6 of both the systems were found.

  19. Development of a youth elixir; La mise en oeuvre d`un elixir de jouvence

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This short paper presents a new refrigerant developed by Quiri Refrigeration company in collaboration with Electricite de France (EdF), which can replace the no-longer produced R-12 CFC. This substitute, called `youth elixir` is a mixture of HCFCs and has similar physical characteristics, is compatible with the R-12 and can be used in a similar pressure range. Its use requires to modify the existing installation but with a reasonable cost. (J.S.)

  20. Effects of Gelatin-Based Edible Films Enriched with Laurel Essential Oil on the Quality of Rainbow Trout (Oncorhynchus mykiss) Fillets During Refrigerated Storage

    OpenAIRE

    Tuba Baygar; Taçnur Baygar; Hatice Hasanhocaoglu; Cansu Metin; Yunus Alparslan

    2014-01-01

    The effects of gelatin films enriched with laurel leaf essential oil on the quality of rainbow trout (Oncorhynchus mykiss) during refrigerated storage at (4±1) °C were examined over a period of 26 days. Fish fillets were wrapped with 8 % gelatin films containing 0, 0.1 and 1 % (by volume per mass) of laurel essential oil and vacuum packaged. Sensory (raw and cooked fish), microbiological (total viable counts, psychrotrophic bacteria counts, Enterobacteriaceae and lactic acid bacteria) and ...

  1. Evaporating heat transfer of R22 and R410A in horizontal smooth and microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Man-Hoe; Shin, Joeng-Seob [Korea Advanced Institute of Science and Technology, Daejeon (Korea). Department of Mechanical Engineering

    2005-09-01

    An experimental investigation of evaporating heat transfer in 9.52 mm O.D. horizontal copper tubes was conducted. The refrigerants tested were R22 and the near-azeotropic mixture, R410A. The test rig had a straight, horizontal test section with an active length of 0.92 m and was heated by the heat transfer fluid (hot water) circulated in a surrounding annulus. Constant heat flux of 11.0 kW/m{sup 2} was maintained and refrigerant quality varied from 0.2 to 0.8.. The results were reported for evaporation at 15 {sup o}C in a 0.92 m long test section for 30-60 kg/h mass flow rate. The local and average heat transfer coefficients for seven microfin tubes were presented compared to those for a smooth tube. The average evaporation heat transfer coefficients of R22 and R410A for the microfin tubes were 1.86-3.27 and 1.64-2.99 times higher than those for the smooth tube, respectively. When compared to R22 at the same test conditions, the evaporating heat transfer coefficients for R410A were 97-129% of R22. (author)

  2. Exhaust of plant oil fuelled cogeneration unit drives a two-stage refrigerating absorber; Abgas aus Pflanzenoel-BHKW treibt zweistufige Absorptionskaeltemaschine an

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, W.

    2008-05-15

    Skating rinks are expensive to operate. In view of exploding energy prices, energetic optimisation is economically favourable even in more recent buildings. In the Hacker-Pschorr-Arena building at Bad Toelz, which was commissioned in 2004, the space HVAC system was modernized. A plant oil fuelled cogeneration unit and an exhaust-driven two-stage refrigerating absorber were installed. (orig.)

  3. Catalytic Partial Oxidation of Biomass/Oil Mixture

    Czech Academy of Sciences Publication Activity Database

    Veselý, Václav; Hanika, Jiří; Tukač, V.; Lederer, J.; Kovač, D.

    2013-01-01

    Roč. 7, č. 10 (2013), s. 1940-1945 ISSN 1934-8983 R&D Projects: GA TA ČR TE01020080; GA MPO 2A-2TP1/024 Institutional support: RVO:67985858 Keywords : hydrocarbon oil * biomass * catalytic partial oxidation Subject RIV: CI - Industrial Chemistry, Chemical Engineering http://www.davidpublishing.com/journals_info.asp?jId=1718#

  4. Protective Activity of the Mixtures of Pine Oil and Copper Hydroxide against Bacterial Spot and Anthracnose on Red Pepper

    Directory of Open Access Journals (Sweden)

    Jae-Woo Soh

    2014-09-01

    Full Text Available This research was performed to examine the protective activities of the mixtures of pine oil and copper hydroxide against bacterial spot and anthracnose on pepper plants. As for bacterial spot, the treatment of pine oil alone displayed high disease incidence (59.6% and low protective effect (28.9%. In comparison, the treatments of mixtures and copper hydroxide alone showed protective activities of 66.8-76.1%. The mixture of pine oil and copper hydroxide (4:1 suppressed the most effectively bacterial spot on pepper. On the other hand, the mixture of pine oil and copper hydroxide (4:1 also showed the strongest protective effect against pepper anthracnose among the 4 treatments tested; its disease incidence and disease control value were 49.8% and 41.7%, respectively. The other treatments showed low protective activities with control values of 7.4-17.1%. These results suggested that the mixture of pine oil and copper hydroxide (4:1 can be used for the environmental-friendly disease control of bacterial spot and anthracnose on pepper.

  5. Study of mixtures based on hydrocarbons used in ORC (Organic Rankine Cycle) for engine waste heat recovery

    International Nuclear Information System (INIS)

    Shu, Gequn; Gao, Yuanyuan; Tian, Hua; Wei, Haiqiao; Liang, Xingyu

    2014-01-01

    For high temperature ORC (Organic Rankine Cycle) used in engine waste heat recovery, it's very critical to select a high temperature working fluid. HCs (Hydrocarbons) usually have excellent cycle performance, but the flammability limits their practical application. Considering that some retardants can be used to suppress flammability, the paper presents an application of mixtures based on hydrocarbons blending with refrigerant retardants to engine waste heat ORC. Three pure hydrocarbons (cyclopentane, cyclohexane, benzene) and two retardants (R11, R123) are selected for combination. Thermal efficiency and exergy loss are selected as the main objective functions. Based on thermodynamic model, the effects of retardants mass fraction, evaporation temperature and IHE (internal heat exchanger) are investigated. Results show that zeotropic mixtures do have higher thermal efficiency and lower exergy loss than pure fluids, at a certain mixture ratio. There exists the OMR (optimal mixture ratio) for different mixtures, and it changes with the evaporation temperature. When adding IHE to system, cycle performance could be obviously improved, and for benzene/R11 (0.7/0.3), the efficiency growth is about 7.12%∼9.72%. Using it, the maximum thermal efficiency of the system can achieve 16.7%, and minimum exergy loss is only 30.76 kW. - Highlights: • A theoretical analysis of Organic Rankine Cycle for engine exhaust heat recovery is proposed. • Mixtures based on hydrocarbons as working fluids have been suggested. • Effects of the IHE (internal heat exchanger) on ORC system are investigated. • OMR (Optimal mixture ratio) changes with the evaporation temperature. • Using the system, maximum thermal efficiency can achieve 16.7%

  6. Investigation of waste heat recovery of binary geothermal plants using single component refrigerants

    Science.gov (United States)

    Unverdi, M.

    2017-08-01

    In this study, the availability of waste heat in a power generating capacity of 47.4 MW in Germencik Geothermal Power Plant has been investigated via binary geothermal power plant. Refrigerant fluids of 7 different single components such as R-134a, R-152a, R-227ea, R-236fa, R-600, R-143m and R-161 have been selected. The binary cycle has been modeled using the waste heat equaling to mass flow rate of 100 kg/s geothermal fluid. While the inlet temperature of the geothermal fluid into the counter flow heat exchanger has been accepted as 110°C, the outlet temperature has been accepted as 70°C. The inlet conditions have been determined for the refrigerants to be used in the binary cycle. Finally, the mass flow rate of refrigerant fluid and of cooling water and pump power consumption and power generated in the turbine have been calculated for each inlet condition of the refrigerant. Additionally, in the binary cycle, energy and exergy efficiencies have been calculated for 7 refrigerants in the availability of waste heat. In the binary geothermal cycle, it has been found out that the highest exergy destruction for all refrigerants occurs in the heat exchanger. And the highest and lowest first and second law efficiencies has been obtained for R-600 and R-161 refrigerants, respectively.

  7. Thermochemical recycling of mixture of scrap tyres and waste lubricating oil into high caloric value products

    International Nuclear Information System (INIS)

    Abdul-Raouf, Manar E.; Maysour, Nermine E.; Abdul-Azim, Abdul-Azim A.; Amin, Mahasen S.

    2010-01-01

    Scrap tyres and used lubricating oils represent together growing environmental problem because they are not biodegradable and their components cannot readily be recovered. In the present investigation, the thermochemical recycling of mixture of old tyres with waste lubricating oil by pyrolysis and the value of the products obtained have been studied. First, thermobalance experiments were carried out, studying the influence of the following variables: temperature, type of catalyst and catalyst concentration on the pyrolysis reaction of a mixture of 1/1 wt./wt. oil/tyre ratio. These thermobalance results were thoroughly investigated to study the effect of the main process variables on yields of derived products: oils, gases and solid residue.

  8. Commissioning and Operational Experience with 1 kW Class Helium Refrigerator/Liquefier for SST-1

    Science.gov (United States)

    Dhard, C. P.; Sarkar, B.; Misra, Ruchi; Sahu, A. K.; Tanna, V. L.; Tank, J.; Panchal, P.; Patel, J. C.; Phadke, G. D.; Saxena, Y. C.

    2004-06-01

    The helium refrigerator/liquefier (R/L) for the Steady State Super conducting Tokamak (SST-1) has been developed with very stringent specifications for the different operational modes. The total refrigeration capacity is 650 W at 4.5 K and liquefaction capacity of 200 l/h. A cold circulation pump is used for the forced flow cooling of 300 g/s supercritical helium (SHe) for the magnet system (SCMS). The R/L has been designed also to absorb a 200 W transient heat load of the SCMS. The plant consists of a compressor station, oil removal system, on-line purifier, Main Control Dewar (MCD) with associated heat exchangers, cold circulation pump and warm gas management system. An Integrated Flow Control and Distribution System (IFDCS) has been designed, fabricated and installed for distribution of SHe in the toroidal and poloidal field coils as well as liquid helium for cooling of 10 pairs of current leads. A SCADA based control system has been designed using PLC for R/L as well as IFDCS. The R/L has been commissioned and required parameters were achieved confirming to the process. All the test results and commissioning experiences are discussed in this paper.

  9. New class of microminiature Joule — Thomson refrigerator and vacuum package

    Science.gov (United States)

    Paugh, Robert L.

    1990-12-01

    Progress is reported on the development of a two-stage, fast cooldown Joule — Thomson refrigerator using nitrogen gas and a nitrogen — hydrocarbon gas mixture as the refrigerants. The refrigerator incorporates a microminiature Venturi pump to reduce the pressure of the exhaust of the main boiler to bring the operating temperature of the cold stage to < 70 K in as little as 10 s. The vacuum package for the refrigerator contains no organic materials and is designed to provide a ten year shelf life. Special glass strengthening techniques are being used to achieve cooler survival of acceleration tests of up to 100 000g.

  10. Optimization of Surfactant Mixtures and Their Interfacial Behavior for Advanced Oil Recovery

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaran, Prof. P.

    2001-02-27

    The goal of this report is to develop improved extraction processes to mobilize and produce the oil left untapped using conventional techniques. Current chemical schemes for recovering the residual oil have been in general less than satisfactory. High cost of the processes as well as significant loss of chemicals by adsorption on reservoir materials and precipitation has limited the utility of chemical-flooding operations. There is a need to develop cost-effective, improved reagent schemes to increase recovery from domestic oil reservoirs. The goal of the report was to develop and evaluate novel mixtures of surfactants for improved oil recovery.

  11. Contribution to the heat transfer analysis of substitute refrigerants in evaporator tubes with smooth or enhanced tube surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Kattan, N

    1997-12-31

    The substitution of CFC refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, requests a good knowledge of heat transfer properties of substitute fluids. A new test facility has been built at the Laboratory for Industrial Energy Systems (LENI) to contribute to this international effort. It consists of two sets of concentric tubes allowing either annular or inside tube convective boiling with a counter current water flow heating to be studied. A new data base including heat transfer coefficients and pressure drop measurements for four new refrigerants (R123, R134A, R402A and R404A) and three older refrigerants (R11, R12 and R502) has been collected. Flow boiling measurements covered a broad range of mass velocities, vapor qualities and heat fluxes. Some of the tests included plain tubes and others enhanced surface tubes (microfilms from Wieland) in horizontal and vertical orientations. An improved Wilson plot technique, that covers both the transition and turbulent flow regimes of the water flowing in the annular channel for the inside tube boiling tests, is proposed to overcome the severe limitations of conventional Wilson plots, to improve accuracy and to facilitate data processing. Mean flow boiling heat transfer coefficients were measured for R12 and R134A evaporating inside a horizontal plain tube and for R11 and R123 evaporating inside a horizontal plain tube. Local flow boiling heat transfer coefficients were measured for : R134A, R123, R404A and R502 evaporating inside a horizontal plain tube, for R134A and R123 evaporating inside a horizontal microfin tube and for R134 evaporating inside a vertical microfin tube. In addition microfin heat transfer augmentation relative to plain tube test data was investigated. The measured heat transfer coefficients were compared to different existing inside tube flow boiling correlations. (author) figs., tabs., refs.

  12. 40 CFR Appendix E to Subpart B of... - The Standard for Automotive Refrigerant Recycling Equipment Intended for Use With Both CFC-12 and...

    Science.gov (United States)

    2010-07-01

    ... Refrigerant Recycling Equipment Intended for Use With Both CFC-12 and HFC-134a E Appendix E to Subpart B of... Appendix E to Subpart B of Part 82—The Standard for Automotive Refrigerant Recycling Equipment Intended for... Intended for Use With Both CFC-12 and HFC-134a Foreword The purpose of this standard is to establish...

  13. Recent investigations on refrigerants for magnetic refrigerators

    International Nuclear Information System (INIS)

    Hashimoto, T.

    1986-01-01

    In development of the magnetic refrigerator, an important problem is selection of magnetic materials as refrigerants. The main purpose of the present paper is to discuss the magnetic and thermal properties necessary for these refrigerants and to report recent investigations. Magnetic refrigerants can be expediently divided into two groups, one for the Carnottype magnetic refrigerator below 20 K and the other for the Ericsson-type refrigerator. The required physical properties of refrigerants in each type of the magnetic refrigerator are first discussed. And then, the results of recent investigations on the magnetic, thermal and magnetocaloric characters of several promising magnetic refrigerants are shown. Finally, a brief prospect of the magnetic refrigerants and refrigerators is given

  14. Boiling Heat Transfer to Halogenated Hydrocarbon Refrigerants

    Science.gov (United States)

    Yoshida, Suguru; Fujita, Yasunobu

    The current state of knowledge on heat transfer to boiling refrigerants (halogenated hydrocarbons) in a pool and flowing inside a horizontal tube is reviewed with an emphasis on information relevant to the design of refrigerant evaporators, and some recommendations are made for future research. The review covers two-phase flow pattern, heat transfer characteristics, correlation of heat transfer coefficient, influence of oil, heat transfer augmentation, boiling from tube-bundle, influence of return bend, burnout heat flux, film boiling, dryout and post-dryout heat transfer.

  15. Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

    Science.gov (United States)

    Rasta, IM; Susila, IDM; Subagia, IWA

    2018-01-01

    The application of refrigeration technology to postharvest fishery products is an very important. Moreover, Indonesia is a tropical region with relatively high temperatures. Fish storage age can be prolonged with a decrease in temperature. Frozen fish can even be stored for several months. Fish freezing means preparing fish for storage in low-temperature cold storage. The working fluid used in cold storage to cool low-temperature chambers and throw heat into high-temperature environments is refrigerant. So far refrigerant used in cold storage is Hydrochloroflourocarbons (HCFC) that is R-22. Chlor is a gas that causes ODP (Ozone Depleting Potential), while Flour is a gas that causes GWP (Global Warming Potential). Government policy began in 2015 to implement Hydrochloroflourocarbons Phase-Out Management Plan. Hydrocarbon (HC) is an alternative substitute for R-22. HC-22 (propane ≥ 99.5%) has several advantages, among others: environmentally friendly, indicated by a zero ODP value, and GWP = 3 (negligible), thermophysical property and good heat transfer characteristics, vapor phase density Which is low, and good solubility with mineral lubricants. The use of HC-22 in cold storage is less than R-22. From the analysis results obtained, cold storage system using HC-22 has better performance and energy consumption is more efficient than the R-22.

  16. Research and Development Roadmap For Next-Generation Low-Global Warming Potential Refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-07-01

    The Department of Energy commissioned this roadmap to establish a set of high-priority research and development (R&D) activities that will accelerate the transition to low-GWP refrigerants across the entire heating, ventilation, air-conditioning and refrigeration (HVAC&R) industry. The schedule of R&D activities occurs within an accelerated five-year timeframe, and covers several prominent equipment types. The roadmap is organized around four primary objectives to: assess and mitigate safety risks, characterize refrigerant properties, understand efficiency and environmental tradeoffs, and support new refrigerant and equipment development.

  17. Experimental investigations on a diesel engine operated with fuel blends derived from a mixture of Pakistani waste tyre oil and waste soybean oil biodiesel.

    Science.gov (United States)

    Qasim, Muhammad; Ansari, Tariq Mahmood; Hussain, Mazhar

    2017-10-18

    The waste tyre and waste cooking oils have a great potential to be used as alternative fuels for diesel engines. The aim of this study was to convert light fractions of pyrolysis oil derived from Pakistani waste vehicle tyres and waste soybean oil methyl esters into valuable fuel and to reduce waste disposal-associated environmental problems. In this study, the waste tyre pyrolysis liquid (light fraction) was collected from commercial tyre pyrolysis plant and biodiesel was prepared from waste soybean oil. The fuel blends (FMWO10, FMWO20, FMWO30, FMWO40 and FMWO50) were prepared from a 30:70 mixture of waste tyre pyrolysis liquid and waste soybean oil methyl esters with different proportions of mineral diesel. The mixture was named as the fuel mixture of waste oils (FMWO). FT-IR analysis of the fuel mixture was carried out using ALPHA FT-IR spectrometer. Experimental investigations on a diesel engine were carried out with various FMWO blends. It was observed that the engine fuel consumption was marginally increased and brake thermal efficiency was marginally decreased with FMWO fuel blends. FMWO10 has shown lowest NOx emissions among all the fuel blends tested. In addition, HC, CO and smoke emissions were noticeably decreased by 3.1-15.6%, 16.5-33.2%, and 1.8-4.5%, respectively, in comparison to diesel fuel, thereby qualifying the blends to be used as alternative fuel for diesel engines.

  18. Alternative Refrigerant Evaluation for High-Ambient-Temperature Environments: R-22 and R-410A Alternatives for Rooftop Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goetzler, William [Navigant Consulting Inc., Burlington, MA (United States); Guernsey, Matt [Navigant Consulting Inc., Burlington, MA (United States); Bargach, Youssef [Navigant Consulting Inc., Burlington, MA (United States)

    2016-09-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for Low-Global Warming Potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants relative to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in packaged or Rooftop Unit (RTU) air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerants selection process, the test procedures, and the final results.

  19. Helium refrigeration system for BNL colliding beam accelerator

    International Nuclear Information System (INIS)

    Brown, D.P.; Farah, Y.; Gibbs, R.J.; Schlafke, A.P.; Schneider, W.J.; Sondericker, J.H.; Wu, K.C.

    1983-01-01

    A Helium Refrigeration System which will supply the cooling required for the Colliding Beam Accelerator at Brookhaven National Laboratory is under construction. Testing of the compressor system is scheduled for late 1983 and will be followed by refrigerator acceptance tests in 1984. The refrigerator has a design capacity of 24.8 kW at a temperature level near 4K while simultaneously producing 55 kW for heat shield loads at 55K. When completed, the helium refrigerator will be the world's largest. Twenty-five oil-injected screw compressors with an installed total of 23,250 horsepower will supply the gas required. One of the unique features of the cycle is the application of three centrifugal compressors used at liquid helium temperature to produce the low temperatures (2.5K) and high flow rates (4154 g/s) required for this service

  20. Quantitative analysis of properties of petroleum mixtures by near infrared spectroscopy; Analise quantitativa de propriedades de misturas de petroleos via espectrofotometria no infravermelho proximo

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Leila M.; Silva, Elisangela B.; Fortuny, Montserrat; Dariva, Claudio; Santos, Alexandre F. [Universidade Tiradentes (UNIT), Aracaju, SE (Brazil). Instituto de Tecnologia e Pesquisa (ITP); Araujo, Augusto M. [Siemens Brazil, Rio de Janeiro, RJ (Brazil); Coutinho, Raquel C.C. [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2008-07-01

    An experimental study is carried out aiming to develop a method of quantitative analysis of properties of petroleum mixtures, such as water and asphaltene contents, heavy oil concentration and viscosity based on the use of a NIR spectrophotometer. A strategy of generation of crude oil mixtures with known properties was developed to help calibrating the NIR spectrophotometer. Petroleum mixtures involving 2 or 3 oils under known ratios were prepared based on a set of different light and heavy Brazilian crude oil samples. Moreover, experimental data of 5 binary mixtures were also assembled into a data set named multi-compound. Results indicated that excellent calibration models can be obtained for binary mixtures with correlation coefficient (R{sup 2}) greater than 99% for water and asphaltene contents, viscosity and heavy oil concentration. For ternary systems, excellent correlations (R{sup 2}>99%) can be attained for asphaltene and heavy oil contents. Finally for the multi-compound data set, the asphaltene content was the only property that resulted in R{sup 2}>99%, which demonstrates the adequacy of the NIR technique for assessing this property. (author)

  1. Analysis of Refrigeration Cycle Performance with an Ejector

    Directory of Open Access Journals (Sweden)

    Wani J. R.

    2016-01-01

    Full Text Available A conventional refrigeration cycle uses expansion device between the condenser and the evaporator which has losses during the expansion process. A refrigeration cycle with ejector is a promising modification to improve the performance of conventional refrigeration cycle. The ejector is used to recover some of the available work so that the compressor suction pressure increases. To investigate the enhancement a model with R134a refrigerant was developed. To solve the set of equations and simulate the cycle performance a subroutine was written on engineering equation solver (EES environment. At specific conditions, the refrigerant properties are obtained from EES. At the design conditions the ejector refrigeration cycle achieved 5.141 COP compared to 4.609 COP of the conventional refrigeration cycle. This means that ejector refrigeration cycle offers better COP with 10.35% improvement compared to conventional refrigeration cycle. Parametric analysis of ejector refrigeration cycle indicated that COP was influenced significantly by evaporator and condenser temperatures, entrainment ratio and diffuser efficiency.

  2. Applicability of ASST-A helium refrigeration system for JLab End Station Refrigerator

    Science.gov (United States)

    Hasan, N.; Knudsen, P.; Ganni, V.

    2017-12-01

    The MØLLER experiment at Jefferson Lab (JLab) is a high power (5 kW) liquid hydrogen target scheduled to be operational in the 12 GeV-era. At present, cryogenic loads and targets at three of JLab’s four experimental halls are supported by the End Station Refrigerator (ESR) - a CTI/Helix 1.5 kW 4.5 K refrigerator. It is not capable of supporting the high power target load and a capacity upgrade of the ESR cryogenic system is essential. The ASST-A helium refrigeration system is a 4 kW 4.5 K refrigerator. It was designed and used for the Superconducting Super Collider Lab (SSCL) magnet string test and later obtained by JLab after the cancellation of that project. The modified ASST-A refrigeration system, which will be called ESR-II along with a support flow from JLab’s Central Helium Liquefier (CHL) is considered as an option for the End Station Refrigerator capacity upgrade. The applicability of this system for ESR-II under varying load conditions is investigated. The present paper outlines the findings of this process study.

  3. Influence of oil on flow condensation heat transfer of R410A inside 4.18 mm and 1.6 mm inner diameter horizontal smooth tubes

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiangchao; Ding, Guoliang; Hu, Haitao; Zhu, Yu.; Peng, Hao [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Gao, Yifeng [International Copper Association Shanghai Office, Shanghai 200020 (China); Deng, Bin [Institute of Heat Transfer Technology, Golden Dragon Precise Copper Tube Group Inc., Shanghai 200135 (China)

    2010-01-15

    The influence of oil on condensation heat transfer of R410A inside 4.18 mm and 1.6 mm inner diameter horizontal smooth tubes is investigated experimentally. The experimental condensing temperature is 40 C, and nominal oil concentration range is from 0% to 5%. The test results indicate that the presence of oil deteriorates the heat transfer, and the deterioration effect becomes obvious with the increase of oil concentration. At oil concentration of 5%, the heat transfer coefficient decreases by maximum 24.9% and 28.5% for 4.18 mm and 1.6 mm tubes, respectively. A new correlation for heat transfer coefficients of R410A-oil mixture flow condensation inside smooth tubes is proposed, which agrees with all the experimental data within a deviation of -30% {proportional_to} +20%. (author)

  4. Thermochemical recycling of mixture of scrap tyres and waste lubricating oil into high caloric value products

    Energy Technology Data Exchange (ETDEWEB)

    Abdul-Raouf, Manar E.; Maysour, Nermine E.; Abdul-Azim, Abdul-Azim A. [Egyptian Petroleum Research Institute, Nasr City, Cairo (Egypt); Amin, Mahasen S. [Faculty of Science, Benha University, Benha (Egypt)

    2010-06-15

    Scrap tyres and used lubricating oils represent together growing environmental problem because they are not biodegradable and their components cannot readily be recovered. In the present investigation, the thermochemical recycling of mixture of old tyres with waste lubricating oil by pyrolysis and the value of the products obtained have been studied. First, thermobalance experiments were carried out, studying the influence of the following variables: temperature, type of catalyst and catalyst concentration on the pyrolysis reaction of a mixture of 1/1 wt./wt. oil/tyre ratio. These thermobalance results were thoroughly investigated to study the effect of the main process variables on yields of derived products: oils, gases and solid residue. (author)

  5. Parametric analysis and optimization for a combined power and refrigeration cycle

    International Nuclear Information System (INIS)

    Wang Jiangfeng; Dai Yiping; Gao Lin

    2008-01-01

    A combined power and refrigeration cycle is proposed, which combines the Rankine cycle and the absorption refrigeration cycle. This combined cycle uses a binary ammonia-water mixture as the working fluid and produces both power output and refrigeration output simultaneously with only one heat source. A parametric analysis is conducted to evaluate the effects of thermodynamic parameters on the performance of the combined cycle. It is shown that heat source temperature, environment temperature, refrigeration temperature, turbine inlet pressure, turbine inlet temperature, and basic solution ammonia concentration have significant effects on the net power output, refrigeration output and exergy efficiency of the combined cycle. A parameter optimization is achieved by means of genetic algorithm to reach the maximum exergy efficiency. The optimized exergy efficiency is 43.06% under the given condition

  6. Compatibility of refrigerants and lubricants with elastomers

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, G.R.; Seiple, R.H.

    1993-01-01

    The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

  7. Performance evaluation of an ejector subcooled vapor-compression refrigeration cycle

    International Nuclear Information System (INIS)

    Xing, Meibo; Yan, Gang; Yu, Jianlin

    2015-01-01

    Highlights: • An ejector subcooled vapor-compression refrigeration cycle is proposed. • The performance of the cycle with ejector subcooling is evaluated theoretically. • Increase in refrigeration capacity can be achieved by the ejector subcooled cycle. • The new cycle exhibits higher COP compared to the basic single-stage cycle. • Performance of the new cycle depends on the operation pressures of the ejector. - Abstract: In this study, a novel vapor-compression refrigeration cycle with mechanical subcooling using an ejector is proposed to improve the performance of a conventional single-stage vapor-compression refrigeration cycle. In the theoretical study, a mathematical model is developed to predict the performance of the cycle by using R404A and R290, and then compared with that of the conventional refrigeration cycle. The simulation results show that the performance of the ejector subcooled cycle is better than that of the conventional cycle. When the evaporator temperature ranges from −40 to −10 °C and the condenser temperature is 45 °C, the novel cycle displays volumetric refrigeration capacity improvements of 11.7% with R404A and 7.2% with R290. And the novel cycle achieves COP improvements of 9.5% with R404A and 7.0% with R290. In addition, the improvement of the COP and cooling capacity of this novel cycle largely depends on the operation pressures of the ejector. The potential practical advantages offered by the cycle may be worth further attention in future studies

  8. Flammability Indices for Refrigerants

    Science.gov (United States)

    Kataoka, Osami

    This paper introduces a new index to classify flammable refrigerants. A question on flammability indices that ASHRAE employs arose from combustion test results of R152a and ammonia. Conventional methods of not only ASHRAE but also ISO and Japanese High-pressure gas safety law to classify the flammability of refrigerants are evaluated to show why these methods conflict with the test results. The key finding of this paper is that the ratio of stoichiometric concentration to LFL concentration (R factor) represents the test results most precisely. In addition, it has excellent correlation with other flammability parameters such as flame speed and pressure rise coefficient. Classification according to this index gives reasonable flammability order of substances including ammonia, R152a and carbon monoxide. Theoretical background why this index gives good correlation is also discussed as well as the insufficient part of this method.

  9. On subcooler design for integrated two-temperature supermarket refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Liang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang, Chun-Lu [College of Mechanical Engineering, Tongji University, No. 4800, Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    The energy saving opportunity of supermarket refrigeration systems using subcooler between the medium-temperature (MT) refrigeration system and the low-temperature (LT) refrigeration system has been identified in the previous work. This paper presents a model-based comprehensive analysis on the subcooler design. The optimal subcooling control is discussed as well. With optimal subcooler size and subcooling control, the maximum energy savings of integrated two-temperature supermarket refrigeration system using R404A or R134a as working fluid can achieve 27% or 20%, respectively. The load ratio of MT to LT system and the operating conditions have considerable impact on the energy savings. (author)

  10. Alternative Refrigerant Evaluation for High-Ambient-Temperature Environments: R-22 and R-410A Alternatives for Mini-Split Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linkous, Randall Lee [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Goetzler, William [Navigant Consulting Inc., Burlington, MA (United States); Guernsey, Matt [Navigant Consulting Inc., Burlington, MA (United States); Kassuga, Theo [Navigant Consulting Inc., Burlington, MA (United States)

    2015-10-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient-Temperature Evaluation Program for low– global warming potential (Low-GWP) Refrigerants aims to develop an understanding of the performance of low-GWP alternative refrigerants to hydrochlorofluorocarbon (HCFC) and hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high-ambient-temperature conditions. This final report describes the parties involved, the alternative refrigerant selection process, the test procedures, and the final results.

  11. Selective Production of 9R-Hydroxy-10E,12Z,15Z-Octadecatrienoic Acid from α-Linolenic Acid in Perilla Seed Oil Hydrolyzate by a Lipoxygenase from Nostoc Sp. SAG 25.82.

    Science.gov (United States)

    Kim, Kyoung-Rok; An, Jung-Ung; Lee, Seon-Hwa; Oh, Deok-Kun

    2015-01-01

    Hydroxy fatty acids (HFAs) derived from omega-3 polyunsaturated fatty acids have been known as versatile bioactive molecules. However, its practical production from omega-3 or omega-3 rich oil has not been well established. In the present study, the stereo-selective enzymatic production of 9R-hydroxy-10E,12Z,15Z-octadecatrienoic acid (9R-HOTE) from α-linolenic acid (ALA) in perilla seed oil (PO) hydrolyzate was achieved using purified recombinant 9R-lipoxygenase (9R-LOX) from Nostoc sp. SAG 25.82. The specific activity of the enzyme followed the order linoleic acid (LA) > ALA > γ-linolenic acid (GLA). A total of 75% fatty acids (ALA and LA) were used as a substrate for 9R-LOX from commercial PO by hydrolysis of Candida rugosa lipase. The optimal reaction conditions for the production of 9R-HOTE from ALA using 9R-LOX were pH 8.5, 15°C, 5% (v/v) acetone, 0.2% (w/v) Tween 80, 40 g/L ALA, and 1 g/L enzyme. Under these conditions, 9R-LOX produced 37.6 g/L 9R-HOTE from 40 g/L ALA for 1 h, with a conversion yield of 94% and a productivity of 37.6 g/L/h; and the enzyme produced 34 g/L 9R-HOTE from 40 g/L ALA in PO hydrolyzate for 1 h, with a conversion yields of 85% and a productivity of 34 g/L/h. The enzyme also converted 9R-hydroxy-10E,12Z-octadecadienoic acid (9R-HODE) from 40 g/L LA for 1.0 h, with a conversion yield of 95% and a productivity of 38.4 g/L. This is the highest productivity of HFA from both ALA and ALA-rich vegetable oil using LOX ever reported. Therefore, our result suggests an efficient method for the production of 9R-HFAs from LA and ALA in vegetable oil using recombinant LOX in biotechnology.

  12. Purification of radioactive waste oil by a supercritical fluid

    International Nuclear Information System (INIS)

    Yoo, Jaeryong; Sung, Jinhyun; Park, Kwangheon; Kim, Hongdoo; Kim, Hakwon; Lim, Taeyoon; Yim, Sanghak; Yoon, Weonseob

    2006-01-01

    The radioactive waste oil from the nuclear industry is potentially hazardous due to its possibility to contaminate soil and underwater. Pollutants in waste oil are generally radioactive heavy metals or organo-metals. Radioactive waste oils are highly viscous fluids that are similar to used-motor oils. Several processes have been developed to regenerated used motor oil, such as acid clay treatment, chemical addition, vacuum distillation, thermal cracking and hydrofinishing. However, these technologies are difficult to apply to separating radioactive nuclides from radioactive waste oils. In recent years, our laboratory developed a membrane method for the regeneration of used motor oils. We applied supercritical Co2 (scCO2) as a viscosity reducing additive to waste oils at a lower process temperature in order to improve membrane permeability and thus the energy saving. However, the membrane cannot filter the contaminants in radioactive waste oil that are not particles, such as radioactive ions in impurity water in the oil. In this paper, we suggest a method extracting clean oil from the radioactive waste oil rather than filtering by a supercritical fluid. We selected R22, a refrigerant, as a solvent for extraction. R22 has a mild critical point - 96.1 .deg. and 49.9bar. Regeneration of waste oils by extracting clean oil using a supercritical fluid such as R22 is easy to handle and reduce secondary wastes. In this paper, we examine the feasibility of R22 in extracting clean oil from radioactive waste oils

  13. Boiling of multicomponent working fluids used in refrigeration and cryogenic systems

    Science.gov (United States)

    Mogorychny, V. I.; Dolzhikov, A. S.

    2017-11-01

    Working fluids based on mixtures are widely used in cryogenic and refrigeration engineering. One of the main elements of low-temperature units is a recuperative heat exchanger where the return flow cools the direct (cold regeneration is carrying out) resulting in continuous boiling and condensation of the multicomponent working fluid in the channels. The temperature difference between the inlet and outlet of the heat exchanger can be more than 100K, which leads to a strong change in thermophysical properties along its length. In addition, the fraction of the liquid and vapor phases in the flow varies very much, which affects the observed flow regimes in the heat exchanger channels. At the moment there are not so many experimental data and analytical correlations that would allow to estimate the heat transfer coefficient during the flow of a two-phase mixture flow at low temperatures. The work is devoted to the study of the boiling process of multicomponent working fluids used in refrigeration and cryogenic engineering. The description of the method of determination of heat transfer coefficient during boiling of mixtures in horizontal heated channel is given as well as the design of the experimental stand allowing to make such measurements. This stand is designed on the basis of a refrigeration unit operating on the Joule-Thomson throttle cycle and makes it possible to measure the heat transfer coefficient with a good accuracy. Also, the calculated values of the heat transfer coefficient, obtained with the use of various correlations, are compared with the existing experimental data. Knowing of the heat transfer coefficient will be very useful in the design of heat exchangers for low-temperature units operating on a mixture refrigerant.

  14. Viscosity and density study for characterization of oil mixtures; Estudo da viscosidade e densidade para caracterizacao das misturas de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Michelle I.; Azevedo, Vildomar S.; Jacinto, Tulio Wagner B. [Aurizonia Petroleo S.A, Natal, RN (Brazil); Vieira, Mariane; Vidal, Rosangela Regia Lima; Garcia, Rosangela Balaban [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)

    2008-07-01

    The oil can be defined as a mixture of hydrocarbons and sulphur, nitrogen and oxygenated organic derivatives at lower amount. There is a practical difficulty of analytical determination of the oil composition, mainly due to the large quantity of medium and heavy oil fractions. For heavier fractions, it is necessary to infer the composition of the cut from properties that can be readily obtained in the laboratory, such as refraction index, density and viscosity. The analysis of oil composition and its fractions is important information on various aspects (IOB et al., 1996): determining the operating conditions of refining, selection of suitable catalysts and mixing operations ('blending'), the economic evaluation of mixtures and analysis of environmental impact due to emissions. The first study on characterization of fractions of the oil was reported by Hill and Coats (1928), who set an empirical relationship between the density and Saybolt viscosity named viscosity-density constant (VGC). The statement was obtained from the analysis of the density with the oil viscosity changes. Physical properties such as density, boiling point and viscosity can be used to classify the oil. The aim of this work was to classify oil fractions based on viscosity-density constant, using mixtures of oils with different APIs. The results showed that there is an optimum composition for each mixture, and the addition of more oil of medium classification does not lead to potential commercial oil. (author)

  15. Smart candle soot coated membranes for on-demand immiscible oil/water mixture and emulsion switchable separation.

    Science.gov (United States)

    Li, Jian; Zhao, Zhihong; Li, Dianming; Tian, Haifeng; Zha, Fei; Feng, Hua; Guo, Lin

    2017-09-21

    Oil/water separation is of great importance for the treatment of oily wastewater, including immiscible light/heavy oil-water mixtures, oil-in-water or water-in-oil emulsions. Smart surfaces with responsive wettability have received extensive attention especially for controllable oil/water separation. However, traditional smart membranes with a switchable wettability between superhydrophobicity and superhydrophilicity are limited to certain responsive materials and continuous external stimuli, such as pH, electrical field or light irradiation. Herein, a candle soot coated mesh (CSM) with a larger pore size and a candle soot coated PVDF membrane (CSP) with a smaller pore size with underwater superoleophobicity and underoil superhydrophobicity were successfully fabricated, which can be used for on-demand immiscible oil/water mixtures and surfactants-stabilized oil/water emulsion separation, respectively. Without any continuous external stimulus, the wettability of our membranes could be reversibly switched between underwater superoleophobicity and underoil superhydrophobicity simply by drying and washing alternately, thus achieving effective and switchable oil/water separation with excellent separation efficiency. We believe that such smart materials will be promising candidates for use in the removal of oil pollutants in the future.

  16. Refrigeration and process engineering: contributions to a better environment; Contributions du genie frigorifique et du genie des procedes pour un meilleur environnement

    Energy Technology Data Exchange (ETDEWEB)

    Bonjour, J.

    2004-05-15

    In order to reach a better environment, two groups of methods can be considered: substituting polluting by clean (or at least with a lower impact) operations or developing pollution treatment solutions. This document first presents various researches in Refrigeration aiming to limit the environmental impact of some activities in this field. For instance, researches on boiling heat transfer -and specifically on the mechanisms governing this phenomenon- are developed. The motivation of such studies lies in the enhancement of evaporators. The effect of the presence of oil or of the choice of zeotropic mixtures on refrigerating machines performances is then highlighted. Lastly, a new method for the optimization (minimization) of the energy consumption of water-cooled ammonia compressors is proposed. Process Engineering provides solutions for the treatment of some air pollutants (e.g. Volatile Organic Compounds or carbon dioxide), among which some use the phenomenon of adsorption, and allow the pollutant separation, capture, concentration and possibly recovery. A new TSA (Temperature Swing Adsorption) process with indirect heating and cooling is developed for performing these operations. This TSA process can be enhanced if combined with other processes such as condensation. The analysis methods typical of Energy Engineering (mainly Refrigeration and Air Conditioning) are shown to be an appreciable help for the optimization of the overall air treatment system. This is the incentive for suggesting the use of a new tool, namely a psychrometric-like chart for nitrogen-toluene mixtures in the presence of an activated carbon adsorbent. (author)

  17. Thermoeconomic optimization of subcooled and superheated vapor compression refrigeration cycle

    International Nuclear Information System (INIS)

    Selbas, Resat; Kizilkan, Onder; Sencan, Arzu

    2006-01-01

    An exergy-based thermoeconomic optimization application is applied to a subcooled and superheated vapor compression refrigeration system. The advantage of using the exergy method of thermoeconomic optimization is that various elements of the system-i.e., condenser, evaporator, subcooling and superheating heat exchangers-can be optimized on their own. The application consists of determining the optimum heat exchanger areas with the corresponding optimum subcooling and superheating temperatures. A cost function is specified for the optimum conditions. All calculations are made for three refrigerants: R22, R134a, and R407c. Thermodynamic properties of refrigerants are formulated using the Artificial Neural Network methodology

  18. Operation characteristic and performance comparison of organic Rankine cycle (ORC) for low-grade waste heat using R245fa, R123 and their mixtures

    International Nuclear Information System (INIS)

    Feng, Yong-qiang; Hung, Tzu-Chen; He, Ya-Ling; Wang, Qian; Wang, Shuang; Li, Bing-xi; Lin, Jaw-Ren; Zhang, Wenping

    2017-01-01

    Highlights: • Experimental comparison using R123, R245fa and their mixtures has been investigated. • The basic operation parameters and the detailed operation characteristics of pure and mixture working fluids are addressed. • The mixture owns a relatively higher pump power consumption, 10–50% higher than that of R245fa and 2–47% higher than that of R123. • The highest system generating efficiency of 4.53% is obtained by 0.67R245fa/0.33R123. - Abstract: The operation characteristic and performance comparison of low-grade organic Rankine cycle (ORC) using R245fa, R123 and their mixtures have been investigated. The heat source temperature is set to be 120 °C, while the mass flow rate is controlled by adjusting the pump frequency. The basic operation parameters are first examined, while the detailed operation characteristics of pure and mixture working fluids are addressed. The system overall performance, including thermal efficiency and system generating efficiency, for pure and mixture working fluids are explored. The experimental results show that the mixtures own a relatively higher pump power consumption and enhancing the pump performance is also significant for ORC application. Whether the mixtures exhibit better thermodynamic performance than the pure working fluids depend on the operation parameters and mass fraction of mixtures. 0.67R245fa/0.33R123 owns the highest maximum net electricity output of 1.67 kW, 4.38% higher than that of R245fa and 63.73% higher than that of R123. Compared to the pure working fluids, the mixture working fluids own a better thermodynamic performance and a moderate economic performance.

  19. Thermoeconomic Optimization of Cascade Refrigeration System Using Mixed Carbon Dioxide and Hydrocarbons at Low Temperature Circuit

    Directory of Open Access Journals (Sweden)

    Nasruddin Nasruddin

    2016-12-01

    Full Text Available Many applications and industrial processes require very low cooling temperature, such as cold storage in the biomedical field, requiring temperature below -80 °C. However,single-cycle refrigeration systems can only achieve the effective cooling temperature of -40 °C and, also, the performance of the cycle will decrease drastically for cooling temperatures lower than -35°C. Currently, most of cascade refrigeration systems use refrigerants that have ozone depletion potential (ODP and global warming potential (GWP, therefore, in this study, a cascade system is simulated using a mixture of environmentally friendly refrigerants, namely, carbon dioxide and a hydrocarbon (propane, ethane or ethylene as the refrigerant of the low temperature circuit. A thermodynamic analysis is performed to determine the optimal composition of the mixture of carbon dioxide and hydrocarbons in the scope of certain operating parameters. In addition, an economic analysis was also performed to determine the annual cost to be incurred from the cascade refrigeration system. The multi-objective/thermoeconomic optimization points out optimal operating parameter values of the system, to addressing both exergy efficiency and its relation to the costs to be incurred.

  20. Effect of temperature on thermoacoustic properties of olive oil in alcohol mixtures

    International Nuclear Information System (INIS)

    Shriwas, R S; Chimankar, O P; Tabhane, P V; Dange, S P; Tembhurkar, Y D

    2012-01-01

    The ultrasonic studies in liquids are great use in understanding the nature and strength of molecular interactions. Recently ultrasonic is the rapidly growing field research, which has been used in the food industry for both analysis and modification of food products. This paper presents ultrasonic velocity, density, adiabatic compressibility in olive oil with alcohol at different concentration that has been measured in the temperature range from 283.15K to 298.15K. The Moelwyn-Hughes parameter has been utilised to establish some simple relations between the available volumes, Bayer's non- linearity parameter, internal pressure, van der Waal's constant, Debye temperature etc. a relationship among the isobaric, isothermal and isochoric thermo-acoustical parameter have been studied and analyzed in the case olive oil with alcohol mixture. The present treatments had the distinct advantages of the thermo-acoustic parameters in the particular mixture.

  1. Numerical research on the scroll compressor with refrigeration injection

    International Nuclear Information System (INIS)

    Wang Baolong; Shi Wenxing; Li Xianting; Yan Qisen

    2008-01-01

    A general model for a scroll compressor with refrigerant injection is established in this paper. The model can be used to predict the macro performance and inner compression process of the injected scroll compressor. A series of experiments are conducted to validate the accuracy of the model. The results show that the model can precisely predict not only the general performance of the compressor but also the inner compression with or without refrigerant injection. Based on the thermodynamic model and the test bench, the injection process of the scroll compressor has been investigated and the thermodynamic essence is revealed. It is found that the refrigerant injection process can be considered as a continual parameter-varying 'adiabatic throttling + isobaric mixture' time-varying process

  2. Effect of vegetable oils on fatty acid composition and cholesterol content of chicken frankfurters

    Science.gov (United States)

    Belichovska, D.; Pejkovski, Z.; Belichovska, K.; Uzunoska, Z.; Silovska-Nikolova, A.

    2017-09-01

    To study the effect of pork adipose tissue substitution with vegetable oils in chicken frankfurters, six frankfurter formulations were produced: control; with pork backfat; with olive oil; with rapeseed oil; with sunflower oil; with palm oil, and; with a mixture of 12% rapeseed oil and 8% palm oil. Fatty acid composition and cholesterol content and some oxides thereof were determined in the final products. The use of vegetable oils resulted in improvement of the fatty acid composition and nutritional of frankfurters. Frankfurters with vegetable oils contained significantly less cholesterol and some of its oxides, compared to the frankfurters with pork fat. The formulation with palm oil had the least favourable fatty acid composition. The use of 12% rapeseed oil improved the ratio of fatty acids in frankfurters with a mixture of rapeseed and palm oils. Complete pork fat replacement with vegetable oils in chicken frankfurter production is technologically possible. The mixture of 12% rapeseed oil and 8% palm oil is a good alternative to pork fat from health aspects. Further research is needed to find the most appropriate mixture of vegetable oils, which will produce frankfurters with good sensory characteristics, a more desirable fatty acid ratio and high nutritional value.

  3. Experimental study on a resorption system for power and refrigeration cogeneration

    International Nuclear Information System (INIS)

    Jiang, L.; Wang, L.W.; Liu, C.Z.; Wang, R.Z.

    2016-01-01

    Energy conversion technologies, especially for power generation and refrigeration technologies driven by the low temperature heat, are gathering the momentum recently. This paper presents a novel resorption system for electricity and refrigeration cogeneraion. Compared with adsorption refrigeration system, resorption refrigeration is characterized as safety and simple structure since there is no ammonia liquid in the system. The cogeneration system is mainly composed of three HTS (high temperature salt) unit beds; three LTS (low temperature salts) unit beds, one expander, three ammonia valves, two oil valves, four water valves and connection pipes. Chemical working pair of MnCl 2 –CaCl 2 –NH 3 is selected. Since scroll expander is suitable for small type power generation system, it is chosen for expansion process. 4.8 kg MnCl 2 and 3.9 kg CaCl 2 impregnated in expanded natural graphite treated with sulfuric acid (ENG-TSA) are filled in the cogeneration system. Experimental results show that maximum cooling power 2.98 kW is able to be obtained while maximum shaft power is about 253 W with 82.3 W average value. The cogeneration system can be utilized for the heat source temperature lower than 170 °C. Total energy efficiency increases from 0.293 to 0.417 then decreases to 0.407 while exergy efficiency increases from 0.12 to 0.16. - Highlights: • A resorption system for power and refrigeration cogeneration is established and investigated. • ENG-TSA as the additive improves the heat and mass performance of composite adsorbent. • The highest shaft power and refrigeration power are 253 W and 2.98 kW, respectively. • Total energy efficiency of the system increases from 0.293 to 0.417 then decreases to 0.407.

  4. 46 CFR 154.1735 - Methyl acetylene-propadiene mixture.

    Science.gov (United States)

    2010-10-01

    ... relieve into the compressor suction line. (4) An alarm that sounds in the cargo control station and in the... mixture must have a refrigeration system without vapor compression or have a refrigeration system with the following features: (1) A vapor compressor that does not raise the temperature and pressure of the vapor...

  5. Evaporating heat transfer characteristics of R22 and R410A in 9.52 mm O.D. smooth and microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M H; Shin, J S; Lim, B H [Sam Sung Electronics Corporation Limited (Korea, Republic of)

    1998-10-01

    An experimental investigation of evaporating heat transfer in 9.52 mm horizontal copper tubes was conducted. The refrigerant tested were R22 and near-azeotropic mixture, R410A. The test rig had a straight, horizontal test section with an active length of 0.92 m and was heated by the heat transfer fluid(hot water) circulated in a surrounding annulus. Constant heat flux of 11.0 kW/m{sup 2} was maintained and refrigerant quality varied from 0.2 to 0.8. The results were reported for evaporation at 15 deg. C in a 0.92 m long test section for 30{approx}60 kg/h mass flow rate. The local and average heat transfer coefficients for seven microfin tubes were presented compared to those for a smooth tube. The average evaporation heat transfer coefficients of R22 and R410A for the microfin tubes were 86{approx}227% and 64{approx}199%, respectively, higher than those for the smooth tube. When compared to R22 at the same test conditions, the evaporating heat transfer coefficients for R410A were 97{approx}129% of R22. (author). 23 refs., 9 figs., 4 tabs.

  6. Control of the Tevatron Satellite Refrigeration system

    International Nuclear Information System (INIS)

    Theilacker, J.; Chapman, L.; Gannon, J.; Hentges, M.; Martin, M.; Rode, C.H.; Zagel, J.

    1984-01-01

    This chapter describes a computerized control system for 24 satellite refrigerators which cool a six kilometer ring of superconducting magnets. The control system consists of 31 independent microprocessors operating over 400 servo loops, and a central computer system which provides monitoring, alarms, logging and changing of parameters. Topics considered include pressure measurement, flow measurement, temperature measurement, gas analysis, control valves, expansion engine controllers, and control loops. Each refrigerator has 12 active microprocessor based control loops which tune the refrigerator to one of its four operating modes: satellite, liquefier, refrigerator, and stand-by. It is suggested that optimizing the refrigerator control loops and quench recovery scheme will minimize the accelerator down time

  7. Curing kinetics of alkyd/melamine resin mixtures

    Directory of Open Access Journals (Sweden)

    Jovičić Mirjana C.

    2009-01-01

    Full Text Available Alkyd resins are the most popular and useful synthetic resins applied as the binder in protective coatings. Frequently they are not used alone but are modified with other synthetic resins in the manufacture of the coatings. An alkyd/melamine resin mixture is the usual composition for the preparation of coating called 'baking enamel' and it is cured through functional groups of resins at high temperatures. In this paper, curing kinetics of alkyd resins based on castor oil and dehydrated castor oil with melamine resin, has been studied by DSC method with programmed heating and in isothermal mode. The results determined from dynamic DSC curves were mathematically transformed using the Ozawa isoconversional method for obtaining the isothermal data. These results, degree of curing versus time, are in good agreement with those determined by the isothermal DSC experiments. By applying the Ozawa method it is possible to calculate the isothermal kinetic parameters for the alkyd/melamine resin mixtures curing using only calorimetric data obtained by dynamic DSC runs. Depending on the alkyd resin type and ratio in mixtures the values of activation energies of curing process of resin mixtures are from 51.3 to 114 kJ mol-1. The rate constant of curing increases with increasing the content of melamine resin in the mixture and with curing temperature. The reaction order varies from 1.12 to 1.37 for alkyd based on dehydrated castor oil/melamine resin mixtures and from 1.74 to 2.03 for mixtures with alkyd based on castor oil. Based on the results obtained, we propose that dehydrated castor oil alkyd/melamine resin mixtures can be used in practice (curing temperatures from 120 to 160°C.

  8. A study of alternative refrigerants for the refrigeration and air conditioning sector in Mauritius

    Science.gov (United States)

    Dreepaul, R. K.

    2017-11-01

    The most frequently used refrigerants in the refrigeration and air conditioning (RAC) sector in Mauritius are currently hydrochlorofluorocarbons (HCFC) and hydrofluorocarbons (HFC). However, because of their strong influence on global warming and the impact of HCFCs on the ozone layer, refrigerants such as ammonia (NH3), carbon dioxide (CO2) and Hydrocarbons (HC), having minimal impact on the environment, are being considered. So far, HCs have only been safely used in domestic refrigeration. Ammonia has been used mainly for industrial refrigeration whereas CO2 is still under study. In this paper, a comparative study of the various feasible alternatives is presented in a survey that was undertaken with major stake holders in the field. The retrofitting possibility of existing equipment was assessed and safety issues associated with each refrigerant were analysed. The major setback of hydrocarbons as a widely accepted refrigerant is its flammability which was considered as a major safety hazard by the majority of respondents in the survey and the main advantages are the improved equipment coefficient of performance (COP) and better TEWI factor. This resulted in a 12 % drop in energy consumption. Despite the excellent thermodynamic properties of ammonia, its use has mainly been confined to industrial refrigeration due to its toxicity. In Mauritius, the performance of ammonia in air conditioning is being evaluated on a pilot basis. The major setback of carbon dioxide as a refrigerant is the high operating pressure which is considered a safety hazard. The high initial investment cost and the lack of qualified maintenance technician is also an issue. The use of CO2 is mainly being considered in the commercial refrigeration sector.

  9. Improving Asphalt Mixture Performance by Partially Replacing Bitumen with Waste Motor Oil and Elastomer Modifiers

    Directory of Open Access Journals (Sweden)

    Sara Fernandes

    2017-08-01

    Full Text Available The environmental concern about waste generation and the gradual decrease of oil reserves has led the way to finding new waste materials that may partially replace the bitumens used in the road paving industry. Used motor oil from vehicles is a waste product that could answer that demand, but it can also drastically reduce the viscosity, increasing the asphalt mixture’s rutting potential. Therefore, polymer modification should be used in order to avoid compromising the required performance of asphalt mixtures when higher amounts of waste motor oil are used. Thus, this study was aimed at assessing the performance of an asphalt binder/mixture obtained by replacing part of a paving grade bitumen (35/50 with 10% waste motor oil and 5% styrene-butadiene-styrene (SBS as an elastomer modifier. A comparison was also made with the results of a previous study using a blend of bio-oil from fast pyrolysis and ground tire rubber modifier as a partial substitute for usual PG64-22 bitumen. The asphalt binders were tested by means of Fourier infrared spectra and dynamic shear rheology, namely by assessing their continuous high-performance grade. Later, the water sensitivity, fatigue cracking resistance, dynamic modulus and rut resistance performance of the resulting asphalt mixtures was evaluated. It was concluded that the new binder studied in this work improves the asphalt mixture’s performance, making it an excellent solution for paving works.

  10. Effects of a mixture of vegetable and essential oils and fatty acid potassium salts on Tetranychus urticae and Phytoseiulus persimilis.

    Science.gov (United States)

    Tsolakis, H; Ragusa, S

    2008-06-01

    Laboratory trials were carried out to evaluate the toxicity and the influence of a commercial mixture of vegetal, essential oils, and potassium salts of fatty acids (Acaridoil 13SL) on the population growth rate (r(i)--instantaneous rate of increase) of two mite species, the phytophagous Tetranychus urticae Koch and the predator Phytoseiulus persimilis Athias-Henriot. A residue of 1.3 mg/cm(2) of pesticide solution was harmless for Ph. persimilis eggs, while a moderate mortality of eggs and of larvae from treated eggs of T. urticae, was observed (53.8%). The pesticide also caused a delay in the postembryonic development of the tetranychid. Moreover, 83.4% mortality was reported for treated females tetranychids and only 24.0% for Ph. persimilis females. The pesticide influenced negatively the population growth of T. urticae which showed a very low rate of increase (r(i)=0.07), compared to that obtained in the control (r(i)=0.68). The pesticide did not affect negatively the reproductive potential of Ph. persimilis (r(i)=0.54 and r(i)=0.57 for test and control, respectively). These results suggest a considerable acaricidal activity of potassium salts of fatty acids and caraway oil on T. urticae and a good selectivity on Ph. persimilis.

  11. Rotary magnetic refrigerator for superfluid helium production

    International Nuclear Information System (INIS)

    Hakuraku, Y.; Ogata, H.

    1986-01-01

    A new rotary-magnetic refrigerator designed to obtain superfluid helium temperatures by executing a magnetic Carnot cycle is developed. A rotor containing 12 magnetic refrigerants (gadolinium-gallium-garnet) is immersed in liquid helium at 4.2 K and rotated at constant speed in a steady magnetic field distribution. Performance tests demonstrate that the new rotary refrigerator is capable of obtaining a temperature of 1.48 K. The maximum useful cooling power obtained at 1.8 K is 1.81 W which corresponds to a refrigeration efficiency of 34%

  12. Stabilization of heavy oil-water emulsions using a bio/chemical emulsifier mixture

    Energy Technology Data Exchange (ETDEWEB)

    Farahbakhsh, A.; Taghizadeh, M.; Movagharnejad, K. [Chemical Engineering Department, Babol University of Technology, Babol (Iran, Islamic Republic of); Yakhchali, B. [National Institute of Genetic Engineering and Biotechnology, Tehran (Iran, Islamic Republic of)

    2011-11-15

    In this study, the viscosity reduction of heavy oil has been investigated through the formation of oil-water emulsion using a bio/chemical emulsifier mixture. Four bioemulsifiers from indigenous Rhodococcus ergthropolis and Bacillus licheniformis strains were used to stabilize a highly-viscous oil-in-water emulsion. The Taguchi method with an L{sub 9} orthogonal array design was used to investigate the effect of various control factors on the formation of the oil/water emulsions. An emulsion with lowest viscosity was formed using ACO4 strain. The substantial stability of the oil-in-water emulsion allows the heavy oil to be transported practically over long distances or remain stationary for a considerable period of time prior to utilization. As the result of Taguchi analysis, the temperature and concentration of the emulsifier had a significant influence on viscosity reduction of the emulsion. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  13. Being everything to anyone: Applicability of thermoacoustic technology in the commercial refrigeration market

    Science.gov (United States)

    Poese, Matthew E.; Smith, Robert W. M.; Garrett, Steven L.

    2005-09-01

    This talk will compare electrodynamically driven thermoacoustic refrigeration technology to some common implementations of low-lift vapor-compression technology. A rudimentary explanation of vapor-compression refrigeration will be presented along with some of the implementation problems faced by refrigeration engineers using compressor-based systems. These problems include oil management, compressor slugging, refrigerant leaks and the environmental impact of refrigerants. Recently, the method of evaluating this environmental impact has been codified to include the direct effects of the refrigerants on global warming as well as the so-called ``indirect'' warming impact of the carbon dioxide released during the generation (at the power plant) of the electrical power consumed by the refrigeration equipment. It is issues like these that generate commercial interest in an alternative refrigeration technology. However, the requirements of a candidate technology for adoption in a mature and risk-averse commercial refrigeration industry are as hard to divine as they are to meet. Also mentioned will be the state of other alternative refrigeration technologies like free-piston Stirling, thermoelectric and magnetocaloric as well as progress using vapor compression technology with alternative refrigerants like hydrocarbons and carbon dioxide.

  14. Numerical investigation of boiling heat transfer on hydrocarbon mixture refrigerant in vertical rectangular minichannel

    Directory of Open Access Journals (Sweden)

    Huixing Li

    2016-05-01

    Full Text Available In order to investigate the characteristics of boiling heat transfer for hydrocarbon mixture refrigerant in plate-fin heat exchanger which is used in the petrochemical industry field, a model was established on boiling heat transfer in vertical rectangular channel. The simulated results were compared with the experimental data from literature. The results show that the deviation between the simulated results and experimental data is within ±15%. Meanwhile, the characteristic of boiling heat transfer was investigated in vertical rectangular minichannel of plate-fin heat exchanger. The results show that the boiling heat transfer coefficient increases with the increase in quality and mass flux and is slightly impacted by the heat flux. This is because that the main boiling mechanism is forced convective boiling while the contribution of nucleate boiling is slight. The correlation of Liu and Winterton is in good agreement with the simulation results. The deviation between correlation calculations and simulation results is mostly less than ±15%. These results will provide some constructive instructions for the understanding of saturated boiling mechanism in a vertical rectangular minichannel and the prediction of heat transfer performance in plate-fin heat exchanger.

  15. The selective partitioning of the oligomers of polyethoxylated surfactant mixtures between interface and oil and water bulk phases.

    Science.gov (United States)

    Graciaa, Alain; Andérez, José; Bracho, Carlos; Lachaise, Jean; Salager, Jean-Louis; Tolosa, Laura; Ysambertt, Fredy

    2006-11-16

    Because their affinities for the oil and water phases vary considerably with the number of ethylene oxide units in their hydrophilic group, the ethoxylated nonionic species occurring in commercial products tend to behave in a non-collective way, with the low ethoxylation oligomers partitioning mostly in the oil phase. This results in a surfactant mixture at the interface which is more hydrophilic than the one which was introduced in the system in the first place. The pseudophase model is used to study the partitioning in Winsor III type systems, and to estimate the deviation of the interfacial mixture composition from the overall one. New results indicate that the selective partitioning into the oil phase increases when the oil phase becomes aromatic, when the total surfactant concentration decreases and when the water-to-oil ratio decreases.

  16. The Safety and Efficacy of a Mixture of Honey, Olive Oil, and Beeswax for the Management of Hemorrhoids and Anal Fissure: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Noori S. Al-Waili

    2006-01-01

    Full Text Available We have found that a mixture of honey, olive oil, and beeswax was effective for treatment of diaper dermatitis, psoriasis, eczema, and skin fungal infection. The mixture has antibacterial properties. A prospective pilot study was conducted to evaluate the therapeutic effect of topical application of the mixture on patients with anal fissure or hemorrhoids.Fifteen consecutive patients, 13 males and 2 females, median age 45 years (range: 28–70, who presented with anal fissure (5 patients or first- to third-degree hemorrhoids (4 with first degree, 4 with second degree, and 2 with third degree, were treated with a 12-h application of a natural mixture containing honey, olive oil, and beeswax in ratio of 1:1:1(v/v/v. Bleeding, itching, edema, and erythema were measured using a scoring method: 0 = none, 1 = mild, 2 = moderate, 3 = severe, and 4 = very severe. The pain score was checked using a visual analog scale (minimum = 0, maximum = 10. Efficacy of treatment was assessed by comparing the symptoms' score before and after treatment; at weekly intervals for a maximum of 4 weeks. The patients were observed for evidence of any adverse effect such as appearance of new signs and symptoms, or worsening of the existing symptoms. The honey mixture significantly reduced bleeding and relieved itching in patients with hemorrhoids. Patients with anal fissure showed significant reduction in pain, bleeding, and itching after the treatment. No side effect was reported with use of the mixture. We conclude that a mixture of honey, olive oil, and beeswax is safe and clinically effective in the treatment of hemorrhoids and anal fissure, which paves the way for further randomized double blind studies.

  17. Optimization of Surfactant Mixtures and Their Interfacial Behavior for Advanced Oil Recovery

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaran, Prof. P.

    2002-03-04

    The objective of this project was to develop a knowledge base that is helpful for the design of improved processes for mobilizing and producing oil left untapped using conventional techniques. The main goal was to develop and evaluate mixtures of new or modified surfactants for improved oil recovery. In this regard, interfacial properties of novel biodegradable n-alkyl pyrrolidones and sugar-based surfactants have been studied systematically. Emphasis was on designing cost-effective processes compatible with existing conditions and operations in addition to ensuring minimal reagent loss.

  18. Image analysis for composition monitoring. Commercial blends of olive and soybean oil - doi: 10.4025/actascitechnol.v35i2.15216

    Directory of Open Access Journals (Sweden)

    Jessica Kehrig Fernandes

    2013-04-01

    Full Text Available Olive oil represents an important component of a healthy and balanced dietary. Due to commercial features, characterization of pure olive oil and commercial mixtures represents an important challenge. Reported techniques can successfully quantify components in concentrations lower than 1%, but may present long delays, too many purification steps or use expensive equipment. Image analysis represents an important characterization technique for food science and technology. By coupling image and UV-VIS spectroscopy analysis, models with linear dependence on parameters were developed and could successfully describe the mixture concentration in the range of 0-100% in mass of olive oil content. A validation sample, containing 25% in mass of olive oil, not used for parameter estimation, was also used for testing the proposed procedure, leading to a prediction of 24.8 ± 0.6. Due to image analysis results,  3-parameter-based models considering only R and G components were developed for olive oil content prediction in mixtures with up to 70% in mass of olive oil, the same test sample was used and its concentration was predicted as 24.5 ± 1.2. These results show that image analysis represents a promising technique for on-line/in-line monitoring of blending process of olive soybean oil for commercial mixtures.  

  19. Co-crystal of (R,R)-1,2-cyclohexanediol with (R,R)-tartaric acid, a key structure in resolution of the ({+-})-trans-diol by supercritical extraction, and the related ternary phase system

    Energy Technology Data Exchange (ETDEWEB)

    Thorey, Paul [Department of Chemical and Environmental Process Engineering, Budapest University of Technology and Economics, H-1521 Budapest (Hungary); Bombicz, Petra [Institute of Structural Chemistry, Chemical Research Center, Hungarian Academy of Science, H-1525 Budapest (Hungary); Szilagyi, Imre Miklos [Material Structure and Modeling Research Group, Hungarian Academy of Sciences, H-1111 Budapest (Hungary); Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1521 Budapest (Hungary); Molnar, Peter; Bansaghi, Gyoergy; Szekely, Edit; Simandi, Bela [Department of Chemical and Environmental Process Engineering, Budapest University of Technology and Economics, H-1521 Budapest (Hungary); Parkanyi, Laszlo [Institute of Structural Chemistry, Chemical Research Center, Hungarian Academy of Science, H-1525 Budapest (Hungary); Pokol, Gyoergy [Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1521 Budapest (Hungary); Madarasz, Janos, E-mail: madarasz@mail.bme.hu [Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, H-1521 Budapest (Hungary)

    2010-01-10

    A novel co-crystal of trans-(R,R)-1,2-cyclohexanediol and (R,R)-tartaric acid (with 1:1 molar ratio, 1) has been found to be a key crystalline compound in the improved resolution of ({+-})-trans-1,2-cyclohexanediol by supercritical fluid extraction. The molecular and crystal structure of this co-crystal, which crystallizes in orthorhombic crystal system (space group P2{sub 1}2{sub 1}2{sub 1}, a = 6.7033(13) A, b = 7.2643(16), c = 24.863(5), Z = 4), has been solved by single crystal X-ray diffraction (R = 0.064). The packing arrangement consists of two dimensional layers of sandwich-like sheets, where the inner part is constructed by double layers of tartaric acids which hydrophilicity is 'covered' on both upper and bottom side by cyclohexanediols with the hydrophobic cyclohexane rings pointing outward. Thus, a rather complex hydrogen bonding pattern is constructed. The relatively high melting point (133 {sup o}C) observed by both simultaneous TG/DTA and DSC, and the main features of FTIR-spectrum of 1 are explained by the increased stability of this crystal structure. DSC studies on binary mixtures of co-crystal 1 with (R,R)-1,2-cyclohexanediol or (R,R)-tartaric acid, revealed eutectic temperatures of T{sub eu} = 100 or 131 {sup o}C, respectively. Between (S,S)-1,2-cyclohexanediol and (R,R)-tartaric acid a eutectic temperature of T{sub eu} = 85 {sup o}C have also been observed. The phase relations have been confirmed by powder X-ray diffraction, as well.

  20. Overview of Air Liquide refrigeration systems between 1.8 K and 200 K

    Science.gov (United States)

    Gondrand, C.; Durand, F.; Delcayre, F.; Crispel, S.; Baguer, G. M. Gistau

    2014-01-01

    Cryogenic refrigeration systems are necessary for numerous applications. Gas purification and distillation require temperatures between 15 K and 200 K depending on the application, space simulation chambers down to 15 K, superconductivity between 1.8 K and up to 75 K (magnets, cavities or HTS devices like cables, FCL, SMES, etc), Cold Neutron Sources between 15 and 20 K, etc. Air Liquide Advanced Technologies is designing and manufacturing refrigerators since 60 years to satisfy those needs. The step by step developments achieved have led to machines with higher efficiency and reliability. In 1965, reciprocating compressors and Joule Thomson expansion valves were used. In 1969, centripetal expanders began to be used. In 1980, oil lubricated screw compressors took the place of reciprocating compressors and a standard range of Claude cycle refrigerators was developed: the HELIAL series. 1980 was also the time for cryogenic centrifugal compressor development. In 2011, driven by the need for lower operational cost (high efficiency and low maintenance), cycle oil free centrifugal compressors on magnetic bearings were introduced instead of screw compressors. The power extracted by centripetal expanders was recovered. Based on this technology, a range of Turbo-Brayton refrigerators has been designed for temperatures between 40 K and 150 K. On-going development will enable widening the range of Turbo-Brayton refrigerators to cryogenic temperatures down to 15 K.. Cryogenic centrifugal circulators have been developed in order to answer to an increasing demand of 4 K refrigerators able to distribute cold power.

  1. Overview of Air Liquide refrigeration systems between 1.8 K and 200 K

    International Nuclear Information System (INIS)

    Gondrand, C.; Durand, F.; Delcayre, F.; Crispel, S.; Baguer, G. M. Gistau

    2014-01-01

    Cryogenic refrigeration systems are necessary for numerous applications. Gas purification and distillation require temperatures between 15 K and 200 K depending on the application, space simulation chambers down to 15 K, superconductivity between 1.8 K and up to 75 K (magnets, cavities or HTS devices like cables, FCL, SMES, etc), Cold Neutron Sources between 15 and 20 K, etc. Air Liquide Advanced Technologies is designing and manufacturing refrigerators since 60 years to satisfy those needs. The step by step developments achieved have led to machines with higher efficiency and reliability. In 1965, reciprocating compressors and Joule Thomson expansion valves were used. In 1969, centripetal expanders began to be used. In 1980, oil lubricated screw compressors took the place of reciprocating compressors and a standard range of Claude cycle refrigerators was developed: the HELIAL series. 1980 was also the time for cryogenic centrifugal compressor development. In 2011, driven by the need for lower operational cost (high efficiency and low maintenance), cycle oil free centrifugal compressors on magnetic bearings were introduced instead of screw compressors. The power extracted by centripetal expanders was recovered. Based on this technology, a range of Turbo-Brayton refrigerators has been designed for temperatures between 40 K and 150 K. On-going development will enable widening the range of Turbo-Brayton refrigerators to cryogenic temperatures down to 15 K.. Cryogenic centrifugal circulators have been developed in order to answer to an increasing demand of 4 K refrigerators able to distribute cold power

  2. Overview of Air Liquide refrigeration systems between 1.8 K and 200 K

    Energy Technology Data Exchange (ETDEWEB)

    Gondrand, C.; Durand, F.; Delcayre, F.; Crispel, S. [AL-AT, 2 rue de Clémencières, 38360 Sassenage (France); Baguer, G. M. Gistau [CRYOGUY, 44, chemin de la Buisse, 38330 Biviers (France)

    2014-01-29

    Cryogenic refrigeration systems are necessary for numerous applications. Gas purification and distillation require temperatures between 15 K and 200 K depending on the application, space simulation chambers down to 15 K, superconductivity between 1.8 K and up to 75 K (magnets, cavities or HTS devices like cables, FCL, SMES, etc), Cold Neutron Sources between 15 and 20 K, etc. Air Liquide Advanced Technologies is designing and manufacturing refrigerators since 60 years to satisfy those needs. The step by step developments achieved have led to machines with higher efficiency and reliability. In 1965, reciprocating compressors and Joule Thomson expansion valves were used. In 1969, centripetal expanders began to be used. In 1980, oil lubricated screw compressors took the place of reciprocating compressors and a standard range of Claude cycle refrigerators was developed: the HELIAL series. 1980 was also the time for cryogenic centrifugal compressor development. In 2011, driven by the need for lower operational cost (high efficiency and low maintenance), cycle oil free centrifugal compressors on magnetic bearings were introduced instead of screw compressors. The power extracted by centripetal expanders was recovered. Based on this technology, a range of Turbo-Brayton refrigerators has been designed for temperatures between 40 K and 150 K. On-going development will enable widening the range of Turbo-Brayton refrigerators to cryogenic temperatures down to 15 K.. Cryogenic centrifugal circulators have been developed in order to answer to an increasing demand of 4 K refrigerators able to distribute cold power.

  3. Thermo-Economic Evaluation of Organic Rankine Cycles for Geothermal Power Generation Using Zeotropic Mixtures

    Directory of Open Access Journals (Sweden)

    Florian Heberle

    2015-03-01

    Full Text Available We present a thermo-economic evaluation of binary power plants based on the Organic Rankine Cycle (ORC for geothermal power generation. The focus of this study is to analyse if an efficiency increase by using zeotropic mixtures as working fluid overcompensates additional requirements regarding the major power plant components. The optimization approach is compared to systems with pure media. Based on process simulations, heat exchange equipment is designed and cost estimations are performed. For heat source temperatures between 100 and 180 °C selected zeotropic mixtures lead to an increase in second law efficiency of up to 20.6% compared to pure fluids. Especially for temperatures about 160 °C, mixtures like propane/isobutane, isobutane/isopentane, or R227ea/R245fa show lower electricity generation costs compared to the most efficient pure fluid. In case of a geothermal fluid temperature of 120 °C, R227ea and propane/isobutane are cost-efficient working fluids. The uncertainties regarding fluid properties of zeotropic mixtures, mainly affect the heat exchange surface. However, the influence on the determined economic parameter is marginal. In general, zeotropic mixtures are a promising approach to improve the economics of geothermal ORC systems. Additionally, the use of mixtures increases the spectrum of potential working fluids, which is important in context of present and future legal requirements considering fluorinated refrigerants.

  4. Alternative Refrigerant Evaluation for High-Ambient Temperature Environments: R-22 and R-410A Alternatives for Mini-Split Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Munk, Jeffrey D [ORNL; Shrestha, Som S [ORNL; Linkous, Randall Lee [ORNL; Goetzler, William [Navigant Consulting Inc.; Guernsey, Matt [Navigant Consulting Inc.; Kassuga, Theo [Navigant Consulting Inc.

    2015-08-01

    The Oak Ridge National Laboratory (ORNL) High-Ambient Temperature Testing Program for Low-GWP Refrigerants aims to develop an understanding of the performance of low-Global Warming Potential (low-GWP) alternatives to Hydrochlorofluorocarbon (HCFC) and Hydrofluorocarbon (HFC) refrigerants in mini-split air conditioners under high ambient temperature conditions. This interim working paper describes the parties involved, the alternative refrigerants selection process, the test procedures, and the preliminary results.

  5. Using Acid Number as a Leading Indicator of Refrigeration and Air Conditioning System Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dennis Cartlidge; Hans Schellhase

    2003-07-31

    This report summarizes a literature review to assess the acidity characteristics of the older mineral oil and newer polyolester (POE) refrigeration systems as well as to evaluate acid measuring techniques used in other non-aqueous systems which may be applicable for refrigeration systems. Failure in the older chlorofluorocarbon/hydrochlorofluorocarbon (CFC/HCFC) / mineral oil systems was primarily due to thermal degradation of the refrigerant which resulted in the formation of hydrochloric and hydrofluoric acids. These are strong mineral acids, which can, over time, severely corrode the system metals and lead to the formation of copper plating on iron surfaces. The oil lubricants used in the older systems were relatively stable and were not prone to hydrolytic degradation due to the low solubility of water in oil. The refrigerants in the newer hydrofluorocarbon (HFC)/POE systems are much more thermally stable than the older CFC/HCFC refrigerants and mineral acid formation is negligible. However, acidity is produced in the new systems by hydrolytic decomposition of the POE lubricants with water to produce the parent organic acids and alcohols used to prepare the POE. The individual acids can therefore vary but they are generally C5 to C9 carboxylic acids. Organic acids are much weaker and far less corrosive to metals than the mineral acids from the older systems but they can, over long time periods, react with metals to form carboxylic metal salts. The salts tend to accumulate in narrow areas such as capillary tubes, particularly if residual hydrocarbon processing chemicals are present in the system, which can lead to plugging. The rate of acid production from POEs varies on a number of factors including chemical structure, moisture levels, temperature, acid concentration and metals. The hydrolysis rate of reaction can be reduced by using driers to reduce the free water concentration and by using scavenging chemicals which react with the system acids. Total acid

  6. Flow, stock, and impact assessment of refrigerants in the Japanese household air conditioner sector.

    Science.gov (United States)

    Xue, Mianqiang; Kojima, Naoya; Machimura, Takashi; Tokai, Akihiro

    2017-05-15

    Refrigerants provide society with great benefits while have the potential to cause adverse effects on the environment and human health. The present study estimated time-dependent flows and stocks and assessed the effects of refrigerants (R-22, R-410a, and R-32) in household air conditioners in Japan. It was found that stock of R-22 and R-410a peaked at 49,147t in 2000 and 55,994t in 2017, respectively. The largest flow of R-22 and R-410a to waste phase occurred at 3417t/yr. in 2005 and 4011t/yr. in 2023, respectively. The total global warming potential (GWP) due to refrigerant emissions increased from 3.6kt CO 2 eq. in 1952 to 6999kt CO 2 eq. in 2019, and then decreased to 5314kt CO 2 eq. in 2030. The ozone depletion potential (ODP) peaked at 141t CFC-11 eq. in 2002. When substituting R-410a for R-22, the ODP decreased 50% while the GDP increased 8%. When substituting R-32 for R-410a, there was no effect on the ODP while the GDP decreased 6%. The human health damage due to the global warming effect of refrigerant emission was much higher than that due to the ozone depleting effect. The refrigerant emission in use and waste management phases dominated the human health damage. The dynamic estimation not only allows us to evaluate the performance of past policies but also supports the future sustainable management associated with the health effects of refrigerants. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Optimization of natural lipstick formulation based on pitaya (Hylocereus polyrhizus) seed oil using D-optimal mixture experimental design.

    Science.gov (United States)

    Kamairudin, Norsuhaili; Gani, Siti Salwa Abd; Masoumi, Hamid Reza Fard; Hashim, Puziah

    2014-10-16

    The D-optimal mixture experimental design was employed to optimize the melting point of natural lipstick based on pitaya (Hylocereus polyrhizus) seed oil. The influence of the main lipstick components-pitaya seed oil (10%-25% w/w), virgin coconut oil (25%-45% w/w), beeswax (5%-25% w/w), candelilla wax (1%-5% w/w) and carnauba wax (1%-5% w/w)-were investigated with respect to the melting point properties of the lipstick formulation. The D-optimal mixture experimental design was applied to optimize the properties of lipstick by focusing on the melting point with respect to the above influencing components. The D-optimal mixture design analysis showed that the variation in the response (melting point) could be depicted as a quadratic function of the main components of the lipstick. The best combination of each significant factor determined by the D-optimal mixture design was established to be pitaya seed oil (25% w/w), virgin coconut oil (37% w/w), beeswax (17% w/w), candelilla wax (2% w/w) and carnauba wax (2% w/w). With respect to these factors, the 46.0 °C melting point property was observed experimentally, similar to the theoretical prediction of 46.5 °C. Carnauba wax is the most influential factor on this response (melting point) with its function being with respect to heat endurance. The quadratic polynomial model sufficiently fit the experimental data.

  8. Optimization of Natural Lipstick Formulation Based on Pitaya (Hylocereus polyrhizus Seed Oil Using D-Optimal Mixture Experimental Design

    Directory of Open Access Journals (Sweden)

    Norsuhaili Kamairudin

    2014-10-01

    Full Text Available The D-optimal mixture experimental design was employed to optimize the melting point of natural lipstick based on pitaya (Hylocereus polyrhizus seed oil. The influence of the main lipstick components—pitaya seed oil (10%–25% w/w, virgin coconut oil (25%–45% w/w, beeswax (5%–25% w/w, candelilla wax (1%–5% w/w and carnauba wax (1%–5% w/w—were investigated with respect to the melting point properties of the lipstick formulation. The D-optimal mixture experimental design was applied to optimize the properties of lipstick by focusing on the melting point with respect to the above influencing components. The D-optimal mixture design analysis showed that the variation in the response (melting point could be depicted as a quadratic function of the main components of the lipstick. The best combination of each significant factor determined by the D-optimal mixture design was established to be pitaya seed oil (25% w/w, virgin coconut oil (37% w/w, beeswax (17% w/w, candelilla wax (2% w/w and carnauba wax (2% w/w. With respect to these factors, the 46.0 °C melting point property was observed experimentally, similar to the theoretical prediction of 46.5 °C. Carnauba wax is the most influential factor on this response (melting point with its function being with respect to heat endurance. The quadratic polynomial model sufficiently fit the experimental data.

  9. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

  10. Method and refrigerants for replacing existing refrigerants in centrifugal compressors

    International Nuclear Information System (INIS)

    Kopko, W.L.

    1991-01-01

    This patent describes a method for replacing an existing refrigerant in a centrifugal compressor. It comprises selecting a desired impeller Mach number for the centrifugal compressor; selecting a base refrigerant constituent; combining at least one additive refrigerant constituent with the base refrigerant constituent to form a replacement refrigerant having at least one physical or chemical property different from the existing refrigerant and substantially providing the desired impeller Mach number in the centrifugal compressor; and replacing the existing refrigerant with the replacement refrigerant

  11. Process optimisation of microwave-assisted extraction of peony ( Paeonia suffruticosa Andr .) seed oil using hexane-ethanol mixture and its characterisation

    Science.gov (United States)

    Xiaoli Sun; Wengang Li; Jian Li; Yuangang Zu; Chung-Yun Hse; Jiulong Xie; Xiuhua Zhao

    2016-01-01

    Ethanol and hexane mixture agent microwave-assisted extraction (MAE) method was conducted to extract peony (Paeonia suffruticosa Andr.) seed oil (PSO). The aim of the study was to optimise the extraction for both yield and energy consumption in mixture agent MAE. The highest oil yield (34.49%) and lowest unit energy consumption (14 125.4 J g -1)...

  12. Gelation of Oil Slicks by Amine Carbamates as an Adjunct to U.S. Navy Oil Spill Recovery Operations

    Science.gov (United States)

    1977-01-14

    plan for a field test in Boston Harbor was to be developed and submitted to the EPA, Coast Guard, state and municipal water control authorities. Di ...Residual Special Fuel Oil #6, and similar oils) was found to be a mixture of 40 g. dodecylamine, 25 R. tetradecylamine, and 4.5 g. hexadecylamine In...solution with 100 g. methyl alcohol. By far the best system, however, was a mixture of 70% dehydroabletylamine ("Amine D", as manufactured by Hercules Corp

  13. Oil spill R ampersand D efforts in Sweden

    International Nuclear Information System (INIS)

    Thorell, D.; Jansson, B.

    1992-01-01

    Let me at first mention some significant facts of the Baltic Sea and of Sweden. It has an average depth of only 60 to 70 meters.The waters are low in temperature as well as low in oxygen and salt content (salinity). The air-temperature is in the winter often lower than minus 20 degrees C. The entrance to the Baltic is very narrow and shallow, which means that it takes thirty years before the water in the Baltic is completely renewed. This makes the Baltic Sea to the world's largest brackish water area where the organisms are very vulnerable and sensitive to all kinds of pollution. Oil spills pose a special threat. Every year, approximately 45 million tons of oil of all types crude, bunker, diesel - to name some - are transported through Swedish waters. The shipping of oil in other parts of the Baltic Sea exceeds this figure; a shipping not subject to our legislation but from time to time, with its spills polluting our environment. Sweden has an extremely long coastline to protect: 14,000 kilometers (nearly 9,000 miles) along the mainland plus the shores of more than 100,000 islands. Some oil spills have contaminated more than 12,000 islands which have large bird and seal populations and are public recreation areas for 1 million people and pleasure boats. Sweden started a comprehensive oil spill R ampersand D programme in 1982. This programme, introduced in this document, is now ended and strategies for the twenty-first century are now being drawn up

  14. PARAMETRIC STUDY OF ENERGY, EXERGY AND THERMOECONOMIC ANALYSES ON VAPOR-COMPRESSION SYSTEM CASCADED WITH LIBR/WATER AND NH3/WATER ABSORBTION CASCADE REFRIGERATION CYCLE

    Directory of Open Access Journals (Sweden)

    ahmet selim dalkilic

    2017-03-01

    Full Text Available Energy savings on cooling systems can be performed by using novel refrigeration cycles. For this aim, vapour compression-vapour absorption cascade refrigeration systems can be considered as substitute to single-stage vapour compression refrigeration systems. Renewable energy sources of geothermal and solar heat, waste heat of processes have been used by these cycles to provide cooling and they also require less electrical energy than vapour compression cycles having alternative refrigerants. In this study, a vapour compression (VC and vapour absorption (VA cascade systems are analysed with the second law analysis for varied cooling capacities. While lithium bromide-water and NH3/H2O are the working fluids in VA part, various refrigerants are used in VC section. The refrigerants of R134a and R600a, R410A and R407C are tested as drop in alternatives for R12 and R22, respectively. The effects of alteration in cooling capacity, superheating and sub cooling in VC part, temperature in the generator and absorber, and degree of overlap in cascade condenser in VA part on the coefficient of system performance are studied. Validation of the results have been performed by the values given in the literature. Improvement in COP of VC, VA and cascade system are obtained separately. According to the analyses, cascade systems’ COP values increase with increasing the temperatures of generator and evaporator and they also increase with decreasing the condenser and absorber temperatures. Moreover, the generator has the highest exergy destruction rates, second and third one were the condenser and absorber, respectively. Electricity consumption and payback period are also determined considering the various parameters of the study.

  15. Fish oil affects immune function in 9 to 12 month old infants

    DEFF Research Database (Denmark)

    Damsgaard, Camilla Trab; Lauritzen, Lotte; Kjær, Tanja

    2006-01-01

    /day) or no fish oil and cow’s milk or infant formula from 9 to 12 month of age in 64 healthy Danish infants. Before and after the intervention we measured the fatty acid composition of erythrocyte (RBC) membranes, plasma IgE levels, C-reactive protein and soluble IL-2 receptors (sIL-2R) as well as cytokine...

  16. Falling R and D in oil companies

    International Nuclear Information System (INIS)

    Creusen, H.; Minne, B.

    2000-01-01

    During the last decade, the research expenditures of the 11 major oil companies and two specialised oil engineers have dropped worldwide. To explain this trend, this article points to an R and D race among the companies and to certain common expectations. The race is due to the absence of knowledge spillovers across the companies, because they need to keep their process innovations secret. Common expectations regarding the high risks of research for new energy sources leads to wait-and-see behaviour instead of own research. A small increase in research efficiency partly compensates for the drop in R and D

  17. Potential benefits of saturation cycle with two-phase refrigerant injection

    International Nuclear Information System (INIS)

    Lee, Hoseong; Hwang, Yunho; Radermacher, Reinhard; Chun, Ho-Hwan

    2013-01-01

    In this paper, a saturation cycle is proposed to enhance a vapor compression cycle performance by reducing thermodynamic losses associated with single phase gas compression and isenthalpic expansion. In order to approach the saturation cycle, a two-phase refrigerant injection technique is applied to the multi-stage cycle. This multi-stage cycle with different options is modeled, and its performance is evaluated under ASHRAE standard operating conditions for air conditioning systems. Moreover, the two-phase refrigerant injection cycle is compared with the typical vapor injection cycle which is utilizing the internal heat exchanger or the flash tank. Low GWP refrigerants are applied to this two-phase refrigerant injection cycle. In terms of the COP and its improvement, R123 has a higher potential than any other refrigerants in the multi-stage cycle. Lastly, practical ideas realizing the saturation cycle are discussed such as multi-stage phase separator, phase separator with helical structure inside, and injection location of the compressor. -- Highlights: • A saturation cycle is proposed to enhance the vapor compression cycle performance. • Two-phase refrigerant injection technique is applied to the multi-stage cycle. • Modeling results of the proposed cycle show the significant performance improvement. • Low GWP refrigerants are applied and R123 shows the highest performance. • New parameters, α and ε, are used to show the potential of the saturation cycle

  18. Identification of unresolved complex mixtures (UCMs) of hydrocarbons in commercial fish oil supplements.

    Science.gov (United States)

    Reid, Anna-Jean M; Budge, Suzanne M

    2015-01-01

    Heightened awareness of the health benefits of fish oil consumption has led to a great increase in the number of fish oil supplements available to the consumer. Therefore manufacturers are continually looking for ways to distinguish their products from those of competitors. Minimally refined or virgin fish oils provide a unique feature; however, petroleum hydrocarbon contamination from oil spills is a reality in the world's oceans. The question arises whether oil produced from fish species caught in these polluted areas is free of petroleum hydrocarbons, with particular interest in unresolved complex mixtures (UCMs). This study investigates the presence of UCMs in commercially available fish oil supplements advertised as being virgin, as well as refined. Weathered petroleum hydrocarbons in the form of a UCM were found at 523 µg g(-1) in a virgin Alaskan salmon oil supplement. Supplements that were refined were free of this contamination. Fish used in the production of fish oil supplements appear to have accumulated petrogenic hydrocarbons in their tissues which were not removed by minimal oil refining. Further study is required to determine if there are any health implications associated with long-term consumption of these contaminated supplements. © 2014 Society of Chemical Industry.

  19. Ternary mixtures of alkyltriphenylphosphonium bromides (C12 TPB ...

    Indian Academy of Sciences (India)

    Administrator

    Critical Micellar Concentrations (CMCs) by conductometry, but their ternary mixtures produce single ... efficiently quenched pyrene fluorescence; the performances of the homologues in this respect were assessed. Keywords ..... The shape of the amphiphile aggregates ..... Haque M E, Das A R and Moulik S P 1999 J. Colloid.

  20. EVALUASI PENGELOLAAN REFRIGERAN CFC, DAN HFC DENGAN MESIN 3R DAN UJI UNJUK KERJA MESIN PENDINGIN STUDI KASUS PADA BENGKEL AC MOBIL DI DENPASAR - BALI

    Directory of Open Access Journals (Sweden)

    I MADE RASTA

    2015-06-01

    Full Text Available CFC refrigerant has been known to be one of causes of ozone layer diminishing and HFC is one of green house gases contributing to global warming through the leak and synthetic refrigerant waste to environment. As a response to the ozone layer diminishment on stratosphere, UNEP, in 1981, through a negotiating process of international stages of development reserve the ozone layer through Wina Convention legalized in March 1985. It was then followed up with Montreal Protocol in September 1987 consisting supervision rules on producing, consuming, and treading ozone damaging materials. The government of Indonesia had ratified the convention through President Decree Number 23 Year 1999. The ozone layer reservation program implementation in Indonesia is facilitated by KLH. Governor of Bali issued Decree Number 523/04-B/HK/2010 on membership restructuring of ozone layer reservation and ozone damaging materials control team work in province of Bali. This research was done in 27 car AC service companies or workshop, which received grant of 3R engine in Denpasar, Bali. The research was dominantly focused on monitoring and evaluation, that is how car AC service company or workshop manage CFC/ R-12 and HFC/R-134a refrigerant at service time using 3R engine that refrigerant does not escape to atmostphere. Cooling machine work procedure test (COP was conducted in laboratory. Research result showed that car AC service company or workshop could manage CFC/ R-12 and HFC /R-l 34a eefctively ( 88,3%. The cooling engine work procedure using CFC /R-12 as the result of 3R engine recovery and recycel resulted in 2,435 while pure CFC/R-12 resulted in 2,54. There were differences in cooling engine work procedure to the use of pure CFC/R-12 refrigerant with that resulted by 3R engine with avarage difference 0,089 or 3,53%.

  1. Essential Oils of Hyptis pectinata Chemotypes: Isolation, Binary Mixtures and Acute Toxicity on Leaf-Cutting Ants.

    Science.gov (United States)

    Feitosa-Alcantara, Rosana B; Bacci, Leandro; Blank, Arie F; Alves, Péricles B; Silva, Indira Morgana de A; Soares, Caroline A; Sampaio, Taís S; Nogueira, Paulo Cesar de L; Arrigoni-Blank, Maria de Fátima

    2017-04-12

    Leaf-cutting ants are pests of great economic importance due to the damage they cause to agricultural and forest crops. The use of organosynthetic insecticides is the main form of control of these insects. In order to develop safer technology, the objective of this work was to evaluate the formicidal activity of the essential oils of two Hyptis pectinata genotypes (chemotypes) and their major compounds on the leaf-cutting ants Acromyrmex balzani Emery and Atta sexdens rubropilosa Forel. Bioassays of exposure pathways (contact and fumigation) and binary mixtures of the major compounds were performed. The major compounds identified in the essential oils of H. pectinata were β-caryophyllene, caryophyllene oxide and calamusenone. The essential oils of H. pectinata were toxic to the ants in both exposure pathways. Essential oils were more toxic than their major compounds alone. The chemotype calamusenone was more toxic to A. balzani in both exposure pathways. A. sexdens rubropilosa was more susceptible to the essential oil of the chemotype β-caryophyllene in both exposure pathways. In general, the binary mixtures of the major compounds resulted in additive effect of toxicity. The essential oils of H. pectinata is a raw material of great potential for the development of new insecticides.

  2. Comparative study during condensation of R152 a and R134 a with presence of non-condensable gas inside a vertical tube

    Science.gov (United States)

    Charef, Adil; Feddaoui, M'barek; Najim, Monssif; Meftah, Hicham

    2018-04-01

    A computational study of the liquid film condensation from vapour-gas mixtures of HFC refrigerants inside a vertical tube is performed. The external wall of the tube is subjected to constant temperature. The model uses an implicit finite difference method to solve the governing equations for the liquid film and gas flow together including the boundary and interfacial matching conditions. Parametric computations were realised to examine the effects of inlet Reynolds number, tube length, and inlet temperature of the gas mixtures on the condensation mechanism. A comparative study between the results obtained for studied R152 a and R134 a with presence of non-condensable gas is made. The predicted results indicate that the condensation of R152 a-air corresponds to a higher accumulated condensation m c d and local heat transfer coefficient h T when compared to R134 a-air in the same conditions. Increasing the inlet Reynolds number or the tube length improve the condensation. Additionally, lower non-condensable gas in R152 a - a i r substantially enhances the heat and mass exchanges.

  3. Acute toxicities of crude oils and oil-dispersant mixtures to Red sea fishes and invertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Eisler, R.

    1975-11-01

    Crude oil from fields in the Persian Gulf and in the Sinai plus a chemical oil dispersant were tested, using static bioassay procedures, for toxicity to adults or juveniles of ten marine species: Heteroxenia fuscescens, a soft coral; Nerita forskali and Drupa granulata, gastropod molluscs; Mytilus variabilis, a mussel; Acanthopleura haddoni, a chiton (mollusc); Echinometra mathaei, sea urchin; Calcinus latens, a hermit crab; Palaemon pacificus, a shrimp; Parupeneus barberinus, goatfish; and Siganus rivulatus, rabbitfish. Concentrations fatal to 50 percent of individual test species in 168 hours, LC-50 (168 h), ranged from 0.74 to more than 30.0 ml/liter for Persian Gulf crude, from 14.5 to more than 30.0 ml/liter for Sinai crude, and from 0.006 to 0.064 ml/liter for the dispersant. In general, fishes and crustaceans were the most sensitive groups assayed and molluscs the most resistant. LC-50 (168 h) values for oil-dispersant mixtures of 10 parts oil to 1 part dispersant (v/v) for selected species ranged from 0.047 to 0.152 ml/liter which appears to reflect the biocidal properties of the dispersant. Some individuals that survived immersion in high concentrations of the test compounds for 168 h were adversely affected during treatment and afterwards.

  4. EXPERIMENTAL PERFORMANCE OF R134a AND R152a USING MICROCHANNEL CONDENSER

    OpenAIRE

    Bhatkar, V. W.

    2018-01-01

    An experimental performance study on vapour compression refrigeration system with R134a and drop in substitute R152a with aluminium microchannel condenser was carried out for condensation temperature of 48°C while evaporation temperature varied from -10 to 15°C. Refrigerant charge of R152a was reduced by 40% over R134a with the microchannel condenser. Performance parameters like work input to the compressor, coefficient of performance, refrigerating capacity, condenser capacity and the produc...

  5. Corrosion of API 5L B and X52 in crude oil/water/gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Perdomo, J J; Gonzalez, J J; Viloria, A; De Veer, H; De Abreu, Y

    2000-02-01

    Laboratory and field tests were conducted to evaluate the corrosion behavior of API 5L grade B and X52 steels using Furrial's crude oil in the presence of water and gas containing carbon dioxide (CO{sub 2}) and hydrogen sulfide (H{sub 2}S). The results suggest that the corrosiveness of this crude oil/water/gas mixture is not detrimental to either steel. However, pitting corrosion was observed. The low general corrosion rates measured were attributed to the natural inhibiting properties of the crude oil.

  6. Investigation of two-phase thermosyphon performance filled with modern HFC refrigerants

    Science.gov (United States)

    Gorecki, Grzegorz

    2018-02-01

    Two-phase closed thermosyphons (TPCTs) are widely utilized as heat exchanger elements in waste heat recovery systems and as passive heating/cooling devices. They are popular because of their high thermal conductivity, simple construction and reliability. Previous researches indicate that refrigerants are performing better than typical TPCT working fluids like deionized water or alcohols in the low temperature range. In the present study three HFC (Hydrofluorocarbons) refrigerants were tested: R134a, R404A and R407C. The total length of the investigated TPCT is 550 mm with equal length (245 mm) condenser and evaporator sections. Its outer diameter is 22 mm with 1 mm wall thickness. The evaporator section was heated by hot water with varying inlet temperature by 5 K step in the range of 288 K - 323 K. The condenser was cooled by cold water with inlet temperature kept at a constant value of 283 K. It was found that using R134a and R404A as working fluids heat transfer rates are the highest. For both refrigerants 10% is optimal filling ratio. They can be utilized interchangeably because the differences between their throughputs are within uncertainty bands. R407C performance was 50% lower. Other disadvantages of using this refrigerant are relatively high working pressures and higher optimal filling ratio (30%).

  7. Refrigeration Playbook: Natural Refrigerants; Selecting and Designing Energy-Efficient Commercial Refrigeration Systems That Use Low Global Warming Potential Refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Caleb [CTA Architects Engineers, Boise, ID (United States); Reis, Chuck [CTA Architects Engineers, Boise, ID (United States); Nelson, Eric [CTA Architects Engineers, Boise, ID (United States); Armer, James [CTA Architects Engineers, Boise, ID (United States); Arthur, Rob [CTA Architects Engineers, Boise, ID (United States); Heath, Richard [CTA Architects Engineers, Boise, ID (United States); Rono, James [CTA Architects Engineers, Boise, ID (United States); Hirsch, Adam [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Doebber, Ian [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    This report provides guidance for selecting and designing energy efficient commercial refrigeration systems using low global warming potential refrigerants. Refrigeration systems are generally the largest energy end use in a supermarket type building, often accounting for more than half of a building's energy consumption.

  8. Tail dependence between oil and stocks of major oil-exporting countries using the CoVaR approach

    Directory of Open Access Journals (Sweden)

    Nader Trabelsi

    2017-12-01

    Full Text Available This paper investigates the negative tail risk dependence between oil shocks and stock indices (at aggregated and desegregated levels for Saudi Arabia (KSA, United Arab Emirates (UAE and Russia, over the period between 2007 and 2016. DCC-MGARCH approach and CoVaR measure are employed to assess the oil shock exposure. The results show that the tail dependence is significant and depends on the origin of the oil shocks, with intensity that varies across countries and sectors. Keywords: Oil price shocks, Oil-exporting countries, Conditional VaR, JEL Classification: C58, G11, Q4

  9. 2017 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    2017-01-01

    This year's lecture programme includes 117 presentations in the five working departments of DKV and 10 lectures at the special event ''Energy-efficient air conditioning in data centres''. The main topics in the respective departments were: (1) Cryogenics: Space applications; Cryogenic plants; Cryomedicine and cryobiology; Components, developments; Processes and plants; Valves, design. (2) Basics: Evaporation, material values; evaporation, condensation; absorption; adsorption, latent storage; cycle simulation. (3) Components: CO 2 plant engineering and components; refrigerants; process control, adsorption, sublimation and storage technology; refrigerating machine oils, heat exchangers and corrosion; components 4.0, sensors and control technology; simulation of plant processes. (4) Cold application: Application; Application / Natural Refrigerants; Mobile Applications Car; Mobile Applications; Supermarket / Efficiency; Optimization / Efficiency. (5) Air conditioning and heat pump applications: load shifting, smart home, flexibility; heat sources and industrial heat pumps; modelling, simulations; energy concepts heat pumps and photovoltaics; monitoring, evaluation; technology trends / working materials. Six papers are separately analyzed for this database. [de

  10. Utilisation de mélanges non-azéotropiques dans les cycles thermodynamiques à compression Use of Non-Azeotropic Mixtures in Thermodynamic Compression Cycles

    Directory of Open Access Journals (Sweden)

    Ambrosino J. L.

    2006-11-01

    Full Text Available L'utilisation de mélanges non-azéotropiques comme fluides frigorigènes présente différents avantages en ce qui concerne le fonctionnement des installations de réfrigération / conditionnement / chauffage mettant en oeuvre des cycles thermodynamiques à compression avec changement de phase. En outre, de tels mélanges représentent une alternative intéressante aux corps purs actuellement recherchés pour résoudre les problèmes d'environnement liés à la destruction de la couche d'ozone. Cet article analyse les connaissances acquises concernant la mise en oeuvre d'une telle solution. The use of non-azeotropic mixtures as refrigerants has various advantages concerning the operating of refrigeration / air-conditioning / heating installations implementing thermodynamic compression cycles with a phase change. Likewise, such mixtures represent an interesting alternative to pure components which are now being looked to as a solution to environmental problems linked to the destruction of the ozone layer. This article analyzes what is known about the implementation of such a solution.

  11. ENERGETIC AND EXERGETIC ASSESSMENT OF DISPLAY CASES USED IN THE MARKET APPLICATIONS FOR PREFERENCE REFRIGERANT

    Directory of Open Access Journals (Sweden)

    M.Ziya SOGUT

    2013-01-01

    Full Text Available This study examines energy and exergy analyses of display cases used to preserve daily products in market applications for different refrigerants. In the study, vapor compression cooling cycle is taken as a model and R22, R134a, R404A and R507C refrigerants used in common application and R407C, R410A and R422D evaluated as alternative refrigerants are studied under constant load in cycle. According to COP and exergy analyses, R134a gas and alternative gas R407C have come forth among the other gases with values 5.33 and 60.86%, and 5.41 and 62.04% respectively. The study finally emphasizes the importance of exergy analysis which is an important method to determine irreversibility of the systems.

  12. Investigation of an experimental ejector refrigeration machine operating with refrigerant R245fa at design and off-design working conditions. Part 1. Theoretical analysis

    KAUST Repository

    Shestopalov, K.O.

    2015-07-01

    © 2015 Elsevier Ltd and IIR.All rights reserved. The ejector refrigeration machine (ERM) offers several advantages over other heat-driven refrigeration machine, including simplicity in design and operation, high reliability and low installation cost, which enable its wide application in the production of cooling. In this paper the theoretical analysis of ejector design and ejector refrigeration cycle performance is presented. It is shown that ERM performance characteristics depend strongly on the operating conditions, the efficiency of the ejector used, and the thermodynamic properties of the refrigerant used. A 1-D model for the prediction of the entrainment ratio ω, and an optimal design for ejectors with cylindrical and conical-cylindrical mixing chambers are presented in this paper. In order to increase ERM performance values, it is necessary first of all to improve the performance of the ejector.

  13. Corrosion of API 5L B and X52 in crude oil/water/gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Perdomo, J.J.; Gonzalez, J.J.; Viloria, A.; De Veer, H.; De Abreu, Y.

    2000-02-01

    Laboratory and field tests were conducted to evaluate the corrosion behavior of API 5L grade B and X52 steels using Furrial's crude oil in the presence of water and gas containing carbon dioxide (CO{sub 2}) and hydrogen sulfide (H{sub 2}S). The results suggest that the corrosiveness of this crude oil/water/gas mixture is not detrimental to either steel. However, pitting corrosion was observed. The low general corrosion rates measured were attributed to the natural inhibiting properties of the crude oil.

  14. A parasitic magnetic refrigerator for cooling superconducting magnet

    International Nuclear Information System (INIS)

    Nakagome, H.; Takahashi, M.; Ogiwara, H.

    1988-01-01

    The application of magnetic refrigeration principle at a liquid helium temperature (4.2K) is very useful for cooling a superconducting magnet for its potential of high efficiency. The magnetic refrigerator equipped with 14 pieces of GGG (gadolinium-gallium-garnet) single crystal unit (30mm in diameter 10mm in length) in the rotating disk operates along the gradient of the magnetic field produced by a racetrack superconducting magnet, whose maximum magnetic field is 4.5 Tesla and the minimum field is 1.1 Tesla. The final goal of their program is to liquefy gaseous helium evaporated from a liquid helium vessel of the racetrack superconducting magnet by the rotating magnetic refrigerator which operates by using the magnetic field of the superconducting magnet. A 0.12W refrigeration power in the 0.72rpm operation has been achieved under condition of 4.2K to 11.5K operation. The helium evaporation rate of this magnet system is estimated as the order of 10mW, and the achieved refrigeration power of 0.12W at 4.2K is sufficient for cooling the superconducting magnet

  15. Study of reverse Brayton cryocooler with Helium-Neon mixture for HTS cable

    Science.gov (United States)

    Dhillon, A. K.; Ghosh, P.

    2017-12-01

    As observed in the earlier studies, helium is more efficient than neon as a refrigerant in a reverse Brayton cryocooler (RBC) from the thermodynamic point of view. However, the lower molecular weight of helium leads to higher refrigerant inventory as compared to neon. Thus, helium is suitable to realize the high thermodynamic efficiency of RBC whereas neon is appropriate for the compactness of the RBC. A binary mixture of helium and neon can be used to achieve high thermodynamic efficiency in the compact reverse Brayton cycle (RBC) based cryocooler. In this paper, an attempt has been made to analyze the thermodynamic performance of the RBC with a binary mixture of helium and neon as the working fluid to provide 1 kW cooling load for high temperature superconductor (HTS) power cables working with a temperature range of 50 K to 70 K. The basic RBC is simulated using Aspen HYSYS V8.6®, a commercial process simulator. Sizing of each component based on the optimized process parameters for each refrigerant is performed based on a computer code developed using Engineering Equation Solver (EES-V9.1). The recommendation is provided for the optimum mixture composition of the refrigerant based on the trade-off factors like thermodynamic efficiency such as the exergy efficiency and equipment considerations. The outcome of this study may be useful for recommending a suitable refrigerant for the RBC operating at a temperature level of 50 K to 70 K.

  16. Design and component testing of a low-temperature waste heat driven refrigeration system. Phases I and II. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Hynek, S.; Borhanian, H.; Krepchin, I.; Walker, D.; Mariano, C.; Fuller, H.; Lee, K.

    1982-03-01

    The design and the component testing of a 20-ton refrigeration system powered by 140/sup 0/F waste heat have been completed. A major advantage of such a system is that essentially all operating power comes from the waste heat with only minor injections of auxiliary power. This Rankine-Rankine system uses R-22 for both power and refrigeration cycles. A single semi-hermetic housing contains the expander, compressor, feed pump, and motor/generator. The integral induction motor/generator acts as a starter, makes up shaft power deficits, absorbs shaft power surpluses, and provides overspeed protection. Experiments determined that 0.0015 in. is the optimum axial clearance for the gerotor R-22 evaporator feed pump to minimize both friction and backleakage, that oil injection to the pump had no effect on either friction or backleage, and that a centrifugal inducer was needed to prevent cavitation under certain operating conditions. Two cylinders of a standard four-cylinder York refrigeration compressor were transformed into expanders to power the remaining two compressor cylinders. Rotary expander valves were used in lieu of conventional poppet valves to lower breathing losses. Testing demonstrated a 75% mechanical efficiency, an 83% isentropic efficiency, and the necessity to support both the rotary valve and the expander wristpins with rolling contact bearings. Fabrication of the 20-ton experimental system is nearing completion and experimental tests are being planned.

  17. ENERGY EFFICIENCY, ENERGY SAVING POTENTIAL AND ENVIRONMENTAL IMPACT RESEARCH OF LPG CARRIER REFRIGERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    V. О. Bedrosov

    2016-12-01

    Full Text Available Nowadays energy efficiency improvement and global warming are issues of current interest because of the natural resources depletion and extreme climate change. Thus, the problem of formation of strict regulations regarding emissions into the air arises. This paper presents the study of cascade refrigeration system for re-condensing of associated petroleum gas during sea transportation for LPG carrier. The structural optimization has been performed. LPG gas carriers with 266 000 m3 ethane capacity require 15 MW cascade refrigeration system for re-condensing if the temperature in the coastal LPG storage is -70°C, and the temperature for transported Ethan is maintained at  -75°C. For current storage conditions the required system cooling capacity is only 1,078 MW intended for the heat gain rejection from the environment during Ethane transportation. The replacement of ozone-depleting refrigerant R22 to alternative agents: R407C, R404A, R402A, R717, R290, R1270 was estimated. The results of analysis have shown that the proposed improvements can be used to optimize the LPG carrier cascade refrigeration system

  18. Studies for the stabilization of coal-oil mixtures. Final report, August 1978-May 1981

    Energy Technology Data Exchange (ETDEWEB)

    Botsaris, G.D.; Glazman, Y.M.; Adams-Viola, M.

    1981-01-01

    A fundamental understanding of the stabilization of coal-oil mixtures (COM) was developed. Aggregation of the coal particles was determined to control both the sedimentation and rheological properties of the COM. Sedimentation stability of COM prepared with coal, 80% < 200 mesh, is achieved by particle aggregation, which leads to the formation of a network of particles throughout the oil. The wettability of coal powders was evaluated by the Pickering emulsion test and a spherical agglomeration test to assess its effect on the stability of various COM formulations. Sedimentation stability of hydrophilic coal-oil-water mixtures (COWM) involves the formation of water bridges between the coal particles, while less stabilization of oleophilic COWM is achieved by the formation of an emulsion. Anionic SAA were least sensitive to the coal type and enhanced the aggregation stability of the suspension. The effect of cationic SAA, nonionic SAA and polymer additives depended upon the specific chemical structure of the SAA, the water content of the COM and the type of coal. The sedimentation stability of ultrafine COM was not directly due to the fineness of the powder but due to the formation of a network of flocculated particles.

  19. Potential Alternative Lower Global Warming Refrigerants for Air Conditioning in Hot Climates

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL; Shen, Bo [ORNL

    2017-01-01

    The earth continues to see record increase in temperatures and extreme weather conditions that is largely driven by anthropogenic emissions of warming gases such as carbon dioxide and other more potent greenhouse gases such as refrigerants. The cooperation of 188 countries in the Conference of the Parties in Paris 2015 (COP21) resulted in an agreement aimed to achieve a legally binding and universal agreement on climate, with the aim of keeping global warming below 2 C. A global phasedown of hydrofluorocarbons (HFCs) can prevent 0.5 C of warming by 2100. However, most of the countries in hot climates are considered as developing countries and as such are still using R-22 (a Hydrochlorofluorocarbon (HCFC)) as the baseline refrigerant and are currently undergoing a phase-out of R-22 which is controlled by current Montreal Protocol to R-410A and other HFC based refrigerants. These HFCs have significantly high Global Warming Potential (GWP) and might not perform as well as R-22 at high ambient temperature conditions. In this paper we present recent results on evaluating the performance of alternative lower GWP refrigerants for R-22 and R-410A for small residential mini-split air conditioners and large commercial packaged units. Results showed that several of the alternatives would provide adequate replacement for R-22 with minor system modification. For the R-410A system, results showed that some of the alternatives were almost drop-in ready with benefit in efficiency and/or capacity. One of the most promising alternatives for R-22 mini-split unit is propane (R-290) as it offers higher efficiency; however it requires compressor and some other minor system modification to maintain capacity and minimize flammability risk. Between the R-410A alternatives, R-32 appears to have a competitive advantage; however at the cost of higher compressor discharge temperature. With respect to the hydrofluoroolefin (HFO) blends, there existed a tradeoff in performance and system design

  20. A binary mixture operated heat pump

    International Nuclear Information System (INIS)

    Hihara, E.; Saito, T.

    1991-01-01

    This paper evaluates the performance of possible binary mixtures as working fluids in high- temperature heat pump applications. The binary mixtures, which are potential alternatives of fully halogenated hydrocarbons, include HCFC142b/HCFC22, HFC152a/HCFC22, HFC134a/HCFC22. The performance of the mixtures is estimated by a thermodynamic model and a practical model in which the heat transfer is considered in heat exchangers. One of the advantages of binary mixtures is a higher coefficient of performance, which is caused by the small temperature difference between the heat-sink/-source fluid and the refrigerant. The mixture HCFC142b/HCFC22 is promising from the stand point of thermodynamic performance

  1. The performance of a residential heat pump operating with a nonazeotropic binary refrigerant mixture

    Science.gov (United States)

    Didion, D.; Mulroy, W.

    Results of laboratory measurement of the performance change of a substantially unmodified residential heat pump designed for 222 when charged with a non azeotropic, binary mixture of R1381 and R152a is presented. Results are presented for various sizes of fixed expansion devices. The effect of gliding temperature in the saturation zone was found to be small. The effect of compositions shift by flash distillation in the accumulator was found to measurably improve low temperature heating performance. It was further observed that some system modification (such as the addition of a receiver) could have further enhanced this low temperature heating performance improvement.

  2. Moringa Seed Oils

    Directory of Open Access Journals (Sweden)

    Joana O. Ilesanmi

    2010-01-01

    Full Text Available This study was conducted to determine the effects of neem (Azadirachta indica A. Juss and moringa (Moringa oleifera seed oils on the storability of cowpea grain. Cowpea samples were treated with various concentrations (0.5, 1.0, and 1.5 mL/200 g cowpea of pure neem and moringa oils and their mixtures in ratios of 1:1, 1:2, and 1:3. The treated cowpea samples were stored for 180 days. Data were collected every 30 days on number of eggs laid, total weevil population, and percentage of uninfested grains and analysed statistically. Significantly different means were compared using LSD at <.05. Increasing oil concentration resulted in better cowpea protection, for example, in oviposition where the control had 6513 eggs, only 8 eggs were recorded in pure neem oil-treated sample at 0.5 mL/200 g. Generally, better results were obtained with higher oil concentrations either in their pure forms or mixtures. The control had a total weevil population of 4988, while most treated samples had none. The control samples had 0% uninfested grains, while 73–94% of uninfested grains were observed in treated samples after 6 months of storage. Therefore, mixture of the oils at 1.5 mL/200 g can be effectively used to store cowpea.

  3. Traditional Mediterranean plants: characterization and use of an essential oils mixture to treat Malassezia otitis externa in atopic dogs.

    Science.gov (United States)

    Nardoni, Simona; Pistelli, Luisa; Baronti, Ilenia; Najar, Basma; Pisseri, Francesca; Bandeira Reidel, Rose Vanessa; Papini, Roberto; Perrucci, Stefania; Mancianti, Francesca

    2017-08-01

    Several plants extracts from Mediterranean countries are traditionally employed in skin troubles both in humans and in animals. Malassezia pachydermatis is a lipophylic yeast responsible for otitis externa and dermatitis in dogs and for cutaneous and systemic disease in humans. Five mixtures of essential oils obtained from Mediterranean plants (Citrus paradisi, Salvia sclarea, Ocimum basilicum, Rosmarinus officinalis, Citrus limon, Anthemis nobilis, Lavandula hybrida and Thymus vulgaris) provided with antifungal and/or anti-inflammatory action assayed in vitro, were tested in vivo versus M. pachydermatis to treat once daily for 2 weeks 25 atopic dogs with Malassezia otitis externa. Mixture composed by C. limon 1%, S. sclarea 0,5%, R. officinalis 1%, A. nobilis 0,5% yielded excellent results in all treated dogs. Despite of clinical resolution after all treatments the number of blastospores did not decrease. This study confirms recent findings suggesting a multifactorial alternative approach for the management of canine Malassezia otitis.

  4. Multiresponse optimisation on biodiesel obtained through a ternary mixture of vegetable oil and animal fat: Simplex-centroid mixture design application

    International Nuclear Information System (INIS)

    Orives, Juliane Resges; Galvan, Diego; Coppo, Rodolfo Lopes; Rodrigues, Cezar Henrique Furtoso; Angilelli, Karina Gomes; Borsato, Dionísio

    2014-01-01

    Highlights: • Mixture experimental design was used which allowed evaluating various responses. • Predictive equation was presented that allows verifying the behavior of the mixtures. • The results depicted that the obtained biodiesel dispensed the use of any additives. - Abstract: The quality of biodiesel is a determining factor in its commercialisation, and parameters such as the Cold Filter Plugging Point (CFPP) and Induction Period (IP) determine its operability in engines on cold days and storage time, respectively. These factors are important in characterisation of the final product. A B100 biodiesel formulation was developed using a multiresponse optimisation, for which the CFPP and cost were minimised, and the IP and yield were maximised. The experiments were carried out according to a simplex-centroid mixture design using soybean oil, beef tallow, and poultry fat. The optimum formulation consisted of 50% soybean oil, 20% beef tallow, and 30% poultry fat and had CFPP values of 1.92 °C, raw material costs of US$ 903.87 ton −1 , an IP of 8.28 h, and a yield of 95.68%. Validation was performed in triplicate and the t-test indicated that there were no difference between the estimated and experimental values for none of the dependent variables, thus indicating efficiency of the joint optimisation in the biodiesel production process that met the criteria for CFPP and IP, as well as high yield and low cost

  5. Involvement of α-, γ- and δ-Tocopherol Isomers from
Pumpkin (Cucurbita pepo L.) Seed Oil or Oil Mixtures in
the Biphasic DPPH˙ Disappearance Kinetics

    OpenAIRE

    Broznić, Dalibor; Jurešić, Gordana Čanadi; Milin, Čedomila

    2016-01-01

    The antioxidant activity of three types of pumpkin seed oil or oil mixtures (cold- -pressed, produced from roasted seed paste and salad) produced in the northern part of Croatia and the kinetics of their behaviour as free radical scavengers were investigated using DPPH˙. In addition, the involvement of oil tocopherol isomers (α-, γ- and δ-) in different steps of DPPH˙ disappearance and their impact on the rate of reaction were analysed. The kinetics of DPPH˙ disappearance is a two-step proces...

  6. CFD investigations on supersonic ejectors for refrigeration applications

    International Nuclear Information System (INIS)

    Bartosiewicz, Y.; Aidoun, Z.; Mercadier, Y.

    2004-01-01

    This paper presents numerical results of a supersonic ejector for refrigeration applications. One of the interesting features is that the current model is based on the NIST properties for the R142b refrigerant: to the authors knowledge, it is the first paper dealing with a local CFD model which takes into account shock-boundary layer interactions in a real refrigerant. The numerical results put demonstrate the crucial role of the secondary nozzle for the mixing rate performance. In addition, these results point out the need of an extensive validation of the turbulence model, especially in the modeling of the off-design mode. (author)

  7. Utilization of carrageenan, citric acid and cinnamon oil as an edible coating of chicken fillets to prolong its shelf life under refrigeration conditions.

    Science.gov (United States)

    Khare, Anshul Kumar; Abraham, Robinson J J; Appa Rao, V; Babu, R Narendra

    2016-02-01

    The present study was conducted to determine efficacy of edible coating of carrageenan and cinnamon oil to enhance the shelf life of chicken meat stored under refrigeration conditions. Chicken breast was coated with carrageenan and cinnamon oil by three methods of application viz., spraying brushing and dipping. The coated meat was evaluated for drip loss, pH, thiobarbituric acid number (TBA), tyrosine value (TV), extract release volume (ERV), Warner-Bratzler shear force value (WBSFV), instrumental color, microbiological, and sensory qualities as per standard procedures. There was a significant difference observed for physicochemical parameters (pH, TBA, TV, ERV, drip loss and WBSFV) and microbiological analysis between storage periods in all the samples and between the control and treatments throughout the storage period but samples did not differed significantly for hunter color scores. However, there was no significant difference among three methods of application throughout the storage period though dipping had a lower rate of increase. A progressive decline in mean sensory scores was recorded along with the increase in storage time. The carrageenan and cinnamon edible coating was found to be a good alternative to enhance the shelf life of chicken meat under refrigeration conditions. It was also observed from study that dipping method of the application had comparatively higher shelf life than other methods of application.

  8. Linking the Value Assessment of Oil and Gas Firms to Ambidexterity Theory Using a Mixture of Normal Distributions

    Directory of Open Access Journals (Sweden)

    Casault Sébastien

    2016-05-01

    Full Text Available Oil and gas exploration and production firms have return profiles that are not easily explained by current financial theory – the variation in their market returns is non-Gaussian. In this paper, the nature and underlying reason for these significant deviations from expected behavior are considered. Understanding these differences in financial market behavior is important for a wide range of reasons, including: assessing investments, investor relations, decisions to raise capital, assessment of firm and management performance. We show that using a “thicker tailed” mixture of two normal distributions offers a significantly more accurate model than the traditionally Gaussian approach in describing the behavior of the value of oil and gas firms. This mixture of normal distribution is also more effective in bridging the gap between management theory and practice without the need to introduce complex time-sensitive GARCH and/or jump diffusion dynamics. The mixture distribution is consistent with ambidexterity theory that suggests firms operate in two distinct states driven by the primary focus of the firm: an exploration state with high uncertainty and, an exploitation (or production state with lower uncertainty. The findings have direct implications on improving the accuracy of real option pricing techniques and futures analysis of risk management. Traditional options pricing models assume that commercial returns from these assets are described by a normal random walk. However, a normal random walk model discounts the possibility of large changes to the marketplace from events such as the discovery of important reserves or the introduction of new technology. The mixture distribution proves to be well suited to inherently describe the unusually large risks and opportunities associated with oil and gas production and exploration. A significance testing study of 554 oil and gas exploration and production firms empirically supports using a mixture

  9. A review – Status of CO2 as a low temperature refrigerant: Fundamentals and R and D opportunities

    International Nuclear Information System (INIS)

    Bansal, Pradeep

    2012-01-01

    Carbon dioxide (CO 2 ) has emerged as one of the most promising and preferred refrigerants for low temperature refrigeration systems in the food and refrigeration industry and/or recreational activities. In recent times, the widespread use of CO 2 refrigerant, particularly in supermarkets, has proved commercially attractive worldwide. Some of the designs that are most commonly used in industry include cascade, transcritical and transcritical booster, while many other interesting designs and variations are also being consistently used for specific situations. This paper presents the holistic view of the fundamentals and application of CO 2 refrigerant in low temperature refrigeration systems, along with some discussion on its benign properties, thermodynamic analysis, the challenges, the need for fundamental research and design of novel systems for its continuing dominance in the refrigeration industry.

  10. Crystallization-induced dynamic resolution R-epimer from 25-OCH3-PPD epimeric mixture.

    Science.gov (United States)

    Zhang, Sainan; Tang, Yun; Cao, Jiaqing; Zhao, Chen; Zhao, Yuqing

    2015-11-15

    25-OCH3-PPD is a promising antitumor dammarane sapogenin isolated from the total saponin-hydrolyzed extract of Panax ginseng berry and Panax notoginseng leaves. 20(R)-25-OCH3-PPD was more potent as an anti-cancer agent than 20(S)-25-OCH3-PPD and epimeric mixture of 25-OCH3-PPD. This paper describes the rapid separation process of the R-epimer of 25-OCH3-PPD from its epimeric mixture by crystallization-induced dynamic resolution (CIDR). The optimized CIDR process was based on single factor analysis and nine well-planned orthogonal design experiments (OA9 matrix). A rapid and sensitive reverse phase high-performance liquid chromatographic (HPLC) method with evaporative light-scattering detector (ELSD) was developed and validated for the quantitation of 25-OCH3-PPD epimeric mixture and crystalline product. Separation and quantitation were achieved with a silica column using a mobile phase consisting of methanol and water (87:13, v/v) at a flow rate of 1.0mL/min. The ELSD detection was performed at 50°C and 3L/min. Under conditions involving 3mL of 95% ethanol, 8% HCl, and a hermetically sealed environment for 72h, the maximum production of 25(R)-OCH3-PPD was achieved with a chemical purity of 97% and a total yield of 87% through the CIDR process. The 25(R)-OCH3-PPD was nearly completely separated from the 220mg 25-OCH3-PPD epimeric mixture. Overall, a simple and steady small-batch purification process for the large-scale production of 25(R)-OCH3-PPD from 25-OCH3-PPD epimeric mixture was developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Modelling refrigerant distribution in microchannel evaporators

    DEFF Research Database (Denmark)

    Brix, Wiebke; Kærn, Martin Ryhl; Elmegaard, Brian

    2009-01-01

    of the refrigerant distribution is carried out for two channels in parallel and for two different cases. In the first case maldistribution of the inlet quality into the channels is considered, and in the second case a non-uniform airflow on the secondary side is considered. In both cases the total mixed superheat...... out of the evaporator is kept constant. It is shown that the cooling capacity of the evaporator is reduced significantly, both in the case of unevenly distributed inlet quality and for the case of non-uniform airflow on the outside of the channels.......The effects of refrigerant maldistribution in parallel evaporator channels on the heat exchanger performance are investigated numerically. For this purpose a 1D steady state model of refrigerant R134a evaporating in a microchannel tube is built and validated against other evaporator models. A study...

  12. Performance Analysis of Solar Combined Ejector-Vapor Compression Cycle Using Environmental Friendly Refrigerants

    Directory of Open Access Journals (Sweden)

    A. B. Kasaeian

    2013-04-01

    Full Text Available In this study, a new model of a solar combined ejector-vapor compression refrigeration system has been considered. The system is equipped with an internal heat exchanger to enhance the performance of the cycle. The effects of working fluid and operating conditions on the system performance including COP, entrainment ratio (ω, compression ratio (rp and exergy efficiency were investigated. Some working fluids suggested are: R114, R141b, R123, R245fa, R600a, R365mfc, R1234ze(e and R1234ze(z. The results show that R114 and R1234ze(e yield the highest COP and exergy efficiency followed by R123, R245fa, R365mfc, R141b, R152a and R600a. It is noticed that the COP value of the new solar ejector-vapor compression refrigeration cycle is higher than that of the conventional ejector cycle with R1234ze(e for all operating conditions. This paper also demonstrates that R1234ze(e will be a suitable refrigerant in the solar combined ejector-vapor compression refrigeration system, due to its environmental friendly properties and better performance. ABSTRAK: Kajian ini menganalisa model baru sistem penyejukan mampatan gabungan ejektor-wap solar.Sistem ini dilengkapi dengan penukar haba dalaman untuk meningkatkan prestasi kitaran.Kesan bendalir bekerja dan keadaan operasi pada prestasi sistem termasuk COP, nisbah pemerangkapan (ω, nisbah mampatan (rp dan kecekapan eksergi telah disiasat.Beberapa bendalir bekerja yang dicadangkan adalah: R114, R141b, R123, R245fa, R600a, R365mfc, R1234ze(e dan R1234ze(z.Hasil kajian menunjukkan R114 dan R1234ze(e menghasilkan COP dan kecekapan eksergi tertinggi diikuti oleh R123, R245fa, R365mfc, R141b, R152a dan R600a.Didapati nilai COP kitaran penyejukan mampatan bagi ejektor-wap solar baru adalah lebih tinggi daripada kitaran ejektor konvensional dengan R1234ze(e bagi semua keadaan operasi.Kertas kerja ini juga menunjukkan bahawa R1234ze(e boleh menjadi penyejuk yang sesuai dalam sistem penyejukan mampatan gabungan ejektor

  13. The R-134a energy efficiency problem

    International Nuclear Information System (INIS)

    Behrens, N.; Dekleva, T.W.; Hartley, J.G.; Murphy, F.T.; Powell, R.L.

    1990-01-01

    This paper examines the controversy over the relative energy efficiencies of R-134a and R-12, from a theoretical thermodynamic perspective. In this regard, the authors have used an in-house process flowsheeting program which allows to simulate the complete thermodynamic cycle, and investigate the effects of superheat and subcooling. Special attention is given to the suitable basis for comparing the energy efficiencies of different refrigerants calculated from thermodynamic data. Modelling experiments demonstrate the relative extent to which R-12 and R-134a respond differently to superheat and subcooling. With appropriate superheat and subcooling taken into consideration, such as applied in standard practice in the home appliance industry, R-134a can provide COP values essentially equivalent to that of R-12

  14. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1998-03-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to thermophysical properties, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air conditioning and refrigeration equipment. It also references documents addressing compatibility of refrigerants and lubricants with other materials.

  15. The disappearance of HCFC 22 and the search for the ideal refrigerant; La disparition du HCFC-22 et le recherche du refrigerant ideal

    Energy Technology Data Exchange (ETDEWEB)

    Dumas, C. [Ville de Montreal, PQ (Canada). Direction des Immeubles Gestion de l' Energie et du Genie Climatique

    2003-03-01

    The City of Montreal, Quebec is searching for the optimum refrigerant, and has determined that ammonia, carbon dioxide, hydrocarbons and refrigerant-mixes in the 400 series are to be considered for general refrigeration and in skating rinks in the next years. The refrigerants of the 400 series contribute to the greenhouse effect and it is not possible to utilize them in sunk type systems. The City of Montreal has 12 per cent of ice surfaces in Quebec. The Montreal Protocol, a United Nations document calls for the gradual elimination of the refrigerant monochlorodifluoromethane (HCFC 22) starting in 2004 and that none will be made after 2020 in order to protect the ozone layer. In this document, the author discussed the following topics: (1) supply problems, regulations, international index used to compare refrigeration systems, (2) the origin of refrigerants available on the market and why the chemical industry is incapable of producing the miracle refrigerant, and (3) a proposal for an action plan for the control and the reduction of HCFC 22 leaks, the replacement of entire refrigeration systems and the preparation for the period following the availability of HCFC 22. The author offered twelve conclusions. 10 refs., 9 figs.

  16. Effects of Gelatin-Based Edible Films Enriched with Laurel Essential Oil on the Quality of Rainbow Trout (Oncorhynchus mykiss Fillets During Refrigerated Storage

    Directory of Open Access Journals (Sweden)

    Tuba Baygar

    2014-01-01

    Full Text Available The effects of gelatin films enriched with laurel leaf essential oil on the quality of rainbow trout (Oncorhynchus mykiss during refrigerated storage at (4±1 °C were examined over a period of 26 days. Fish fillets were wrapped with 8 % gelatin films containing 0, 0.1 and 1 % (by volume per mass of laurel essential oil and vacuum packaged. Sensory (raw and cooked fish, microbiological (total viable counts, psychrotrophic bacteria counts, Enterobacteriaceae and lactic acid bacteria and chemical (proximate composition, pH, total volatile base nitrogen (TVB-N, thiobarbituric acid (TBA, free fatty acid (FFA and peroxide value (PV analysis, and colour measurement were carried out during the storage period and shelf-life was determined periodically. The obtained results showed that the gelatin film enriched with laurel essential oil was suitable for the preservation of rainbow trout fillet and the ability of laurel essential oil to preserve the film depended on its ratio. Combined effects of gelatin film and laurel essential oil (1 % by volume per mass was efficient in maintaining the quality characteristics at an acceptable level up to 22 days of storage, while the control and gelatin film without the essential oil reached an unacceptable level at 15 and 20 days, respectively.

  17. Advanced exergy analysis of a R744 booster refrigeration system with parallel compression

    DEFF Research Database (Denmark)

    Gullo, Paride; Elmegaard, Brian; Cortella, Giovanni

    2016-01-01

    In this paper, the advanced exergy analysis was applied to a R744 booster refrigeration system with parallel compression taking into account the design external temperatures of 25 degrees C and 35 degrees C, as well as the operating conditions of a conventional European supermarket. The global...... efficiencies of all the chosen compressors were extrapolated from some manufactures' data and appropriated optimization procedures of the performance of the investigated solution were implemented.According to the results associated with the conventional exergy evaluation, the gas cooler/condenser, the HS (high...... stage) compressor and the MT (medium temperature) display cabinet exhibited the highest enhancement potential. The further splitting of their corresponding exergy destruction rates into their different parts and the following assessment of the interactions among the components allowed figuring out...

  18. Nucleate boiling of halogenated coolants - correlation analysis; Ebulicao nucleada de refrigerantes halogenados: analise de correlacoes

    Energy Technology Data Exchange (ETDEWEB)

    Ribatski, Gherhardt; Jabardo, Jose M. Saiz [Sao Paulo Univ., Sao Carlos, SP (Brazil). Escola de Engenharia. Dept. de Engenharia Mecanica

    1998-07-01

    Present study has been focused on a literature of heat transfer under nucleate boiling conditions of halocarbon refrigerants and their mixtures with lubricating oil. Two kind of correlations regarding the heat transfer mechanism have been found: strictly empirical, based on a straight curve fitting of experimental data, and semi-empirical, based on the particular point of view of the author regarding the physical mechanism but still fitted with experimental data. As a general rule, it has been noted that correlations present significant discrepancies among each other, a result which mostly reflects the wide range of experimental conditions used as a reference. A similar trend has been observed with refrigerant/oil mixtures. Given the current status of halocarbon refrigerants for refrigeration applications, there is clearly a need for further research regarding the nucleate boiling phenomenon related to those compounds. (author)

  19. Effect of a herbal essential oil mixture on growth and internal organ ...

    African Journals Online (AJOL)

    Dietary treatments were: a control and two diets containing 24 mg/kg or 48 mg/kg of an essential oil mixture. There were no significant effects of dietary treatment on body weight of the broilers at 21 and 42 days. The effect of the age of the parents did not have a significant effect on body weight of the broilers at 21 and 42 ...

  20. Enhancement of isobutane refrigerator performance by using far-infrared coating

    International Nuclear Information System (INIS)

    Hsu, Yu-Chun; Teng, Tun-Ping

    2016-01-01

    Highlights: • Two-step synthesis method was employed to produce FIRCs. • Emissivity of FIRCs was determined using a FT-IR. • The highest emissivity of FIRMs was MWCNT. • No-load pull-down and 24-h on-load cycling test were performed. • The COP and EF of S2 were greater than those of S1 by 5.92% and 7.89%. - Abstract: This study evaluated the effect on refrigeration performance and feasibility of a far-infrared coating (FIRC) on the condenser of a small isobutane (R-600a) refrigerator. The evaluation was based on the no-load pull-down and 24-h on-load cycling tests. Far-infrared materials and a water-based coating material were mixed using a two-step synthesis method to obtain the FIRC material. Fourier transform infrared spectrometry established that the optimal far-infrared material was a multiwalled carbon nanotube (MWCNT). The results of the no-load pull-down test revealed that the electricity consumption, freezer temperature, and coefficient of performance (COP) of the R-600a refrigerator with MWCNT-FIRC (S2) were lower than those of the refrigerator without MWCNT-FIRC (S1) by 3.39%, 3.61%, and 2.92%, respectively. The results of the 24-h on-load cycling test showed that S2 had a lower electricity consumption, higher slope of pull-down (SPD), higher compression ratio (CR), higher COP, lower duty ratio (DR), and higher energy factor (EF), changing upon those of S1 by −7.05%, 5.66%, 3.24%, 5.92%, −5.63, and 7.89%, respectively. A MWCNT-FIRC on the condenser of an R-600a refrigerator can enhance refrigeration performance and reduce electricity consumption, resulting in energy saving and carbon reduction.

  1. Competitive adsorption behaviors of carbon dioxide and n-dodecane mixtures in 13X molecular sieve

    Science.gov (United States)

    Zhu, Chaofan; Dong, Mingzhe; Gong, Houjian

    2018-01-01

    The CO2 cyclic injection has been proven to be effective to enhance tight oil recovery under constant reservoir temperature and down hole pressure conditions. However, the enhance tight oil recovery mechanism was unclear, especially the adsorption of the CO2 and alkane in the surface. Therefore, it is great important to study the adsorption mechanism of CO2 and alkane mixtures in tight oil. In this study, a new experimental method and apparatus have been designed to test the change of the mole fraction of CO2 and n-C12 before and after the adsorption equilibrium. Then, the adsorption amount of CO2 and n-C12 was obtained by a mathematical method. Moreover, the adsorption character of CO2 and n-C12 mixtures in 13X molecular sieve and the effect of pressure on the adsorption and amount were studied. The results show that the adsorption of CO2 and the desorption of n-C12 follow the Langmuir adsorption. This study provides a straightforward method to experimentally determine the adsorption properties of the tight oil, which can be used to evaluate enhanced tight oil recovery by CO2 injection.

  2. Thermoacoustic refrigeration

    Science.gov (United States)

    Garrett, Steven L.; Hofler, Thomas J.

    1991-12-01

    A new refrigerator which uses resonant high amplitude sound in inert gases to pump heat is described and demonstrated. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). The thermoacoustic refrigerator has no sliding seals, requires no lubrication, uses only low-tolerance machine parts, and contains no expensive components. Because the compressor moving mass is typically small and the oscillation frequency is high, the small amount of vibration is very easily isolated. This low vibration and lack of sliding seals makes thermoacoustic refrigeration an excellent candidate for food refrigeration and commercial/residential air conditioning applications. The design, fabrication, and performance of the first practical, autonomous thermoacoustic refrigerator, which will be flown on the Space Shuttle (STS-42), are described, and designs for terrestrial applications are presented.

  3. FUZZY THERMOECONOMIC APPROACH TO NANOFLUID SELECTION IN VAPOR COMPRESSION REFRIGERATION CYCLE

    Directory of Open Access Journals (Sweden)

    D. Kuleshov

    2014-06-01

    Full Text Available The working fluid selection in the vapour compression refrigeration cycles has been studied as a fuzzy thermoeconomic optimization problem. Three criteria: thermodynamic (COP Coefficient Of Performance, economic (LCC Life Cycle Cost, and ecologic (GWP – Global Warming Potential are chosen as target functions. The decision variables X as an information characteristics of desired refrigerant are presented by its critical parameters and normal boiling temperature. Local criteria are expressed via thermodynamic properties restored from information characteristics of refrigerant X, as well as life cycle costs are calculated by the standard economic relationships. GWP values are taken from the refrigerant database. Class of substances under consideration is presented by the natural refrigerant R600a embedded with nanostructured materials.

  4. The climate change implications of manufacturing refrigerants. A calculation of 'production' energy contents of some common refrigerants

    International Nuclear Information System (INIS)

    Campbell, N.J.; McCulloch, A.

    1998-01-01

    Total Equivalent Warming Impact (TEWI) analysis has been shown to be a useful aid to quantifying the climate change effect of potential emissions from the operation of systems that involve the use of greenhouse gases and consume energy, so generating CO 2 emissions. It enables these systems to be optimized for minimum global warming impact. In previous studies, the energies required to manufacture the greenhouse gases themselves were not included; by analogy with other chemical manufacturing processes they were assumed to be small in the context of climate change. In the work described here, climate change impacts from the energy used to produce a number of common refrigerant fluids are evaluated. These impacts are compared with the potential impact on global warming from the other components of TEWI: use and disposal of the refrigerants, including direct release into the environment. It is shown that the implications for climate change of the production of traditional refrigerants like ammonia, hydrocarbons or CFC-12 and new refrigerating fluids, such as HFC-134a, are truly insignificant in comparison with other stages of the life cycle of a refrigerator and have no role in TEWI. (author)

  5. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1999-01-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  6. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-07-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  7. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-11-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  8. Computer-Aided Chemical Product Design Framework: Design of High Performance and Environmentally Friendly Refrigerants

    DEFF Research Database (Denmark)

    Cignitti, Stefano; Zhang, Lei; Gani, Rafiqul

    properties and needs should carefully be selected for a given heat pump cycle to ensure that an optimum refrigerant is found? How can cycle performance and environmental criteria be integrated at the product design stage and not in post-design analysis? Computer-aided product design methods enable...... the possibility of designing novel molecules, mixtures and blends, such as refrigerants through a systematic framework (Cignitti et al., 2015; Yunus et al., 2014). In this presentation a computer-aided framework is presented for chemical product design through mathematical optimization. Here, molecules, mixtures...... and blends, are systematically designed through a decomposition based solution method. Given a problem definition, computer-aided molecular design (CAMD) problem is defined, which is formulated into a mixed integer nonlinear program (MINLP). The decomposed solution method then sequentially divides the MINLP...

  9. Variability of Phenolic and Volatile Compounds in Virgin Olive Oil from Leccino and Istarska Bjelica Cultivars in Relation to Their Fruit Mixtures

    Directory of Open Access Journals (Sweden)

    Olivera Koprivnjak

    2012-01-01

    Full Text Available Phenolic and volatile compounds are closely related to valuable gastronomic and nutritional properties, as well as oxidative stability of virgin olive oil. Since biochemical synthesis and transformation of these compounds during olive processing depend on the activity of endogenous enzymes, which are partially influenced by genetic factors, mixtures of different cultivars could have either a synergistic or antagonistic effect on phenolic and volatile compounds in the resulting oil. In this context, two specific cultivars from the Istrian peninsula, Leccino (L and Istarska bjelica (B, were selected. Two monovarietal fruit samples (L100 and B100 and four mixtures in the following mass ratios: L/B=80:20, L/B=60:40, L/B=40:60 and L/B=20:80 were prepared. The mass fraction of total phenols was determined colourimetrically, while C6 and C5 volatiles from lipoxygenase pathway were determined by headspace solid-phase microextraction-gas chromatography. Mass fraction of total phenols in the oil samples from fruit mixtures changed linearly from (199.5±7.2 in Leccino to (642.0±61.7 mg/kg in Istarska bjelica, in a strict correlation with fruit mass ratio of the two cultivars. Leccino monovarietal samples had statistically higher values (p≤0.05 of C6 aldehydes ((15.32±1.69 vs. (10.91±0.62 mg/kg and C6 alcohols ((2.96±0.98 vs. (0.17±0.05 mg/kg, but lower values of C5 compounds ((0.77±0.12 vs. (0.96±0.05 mg/kg compared to Istarska bjelica samples. Volatiles having a direct contribution to the oil aroma (odour activity value >1.0 were 1-penten-3-one (84–201, E-2-hexenal (26–42, hexanal (1.8–2.4 and Z-2-penten-1-ol (1.3–2.6. A significant synergistic effect was observed for C6 aldehydes in the case of L/B=40:60 fruit mixture. The addition of Istarska bjelica to Leccino fruits caused a significant antagonistic effect on C6 alcohols, but no significant deviations from the expected values were found in the case of C6 esters and C5 compounds

  10. Performance comparison of air source heat pump with R407C and R22 under frosting and defrosting

    International Nuclear Information System (INIS)

    Liu Zhiqiang; Li Xiaolin; Wang Hanqing; Peng Wangming

    2008-01-01

    The dynamic performance characteristics of the air source heat pump (ASHP) with refrigerants R22 and R407C during frosting and defrosting are studied. The results show that both refrigerant systems have similar performance characteristics, except that the performance of the R407C system deteriorated faster than that of the R22 system under frosting, and the performance of the R407C system attains its steady state faster than that of the R22 system after defrosting. R407C refrigerant can be used in either existing systems or in new systems that were originally designed for R22

  11. Condensation heat transfer coefficients of flammable refrigerants on various enhanced tubes

    International Nuclear Information System (INIS)

    Park, Ki Jung; Jung, Dong Soo

    2005-01-01

    In this study, external condensation Heat Transfer Coefficients (HTCs) of six flammable refrigerants of propylene (R1270), propane (R290), isobutane (R600a), butane (R600), dimethylether (RE170), and HFC32 were measured at the vapor temperature of 39 .deg. C on a 1023 fpm low fin and turbo-C tubes. All data were taken under the heat flux of 32∼116 and 42∼142 kW/m 2 for the low fin and turbo-C tubes respectively. Flammable refrigerants' data obtained on enhanced tubes showed a typical trend that external condensation HTCs decrease with increasing wall subcooling. HFC32 and DME showed up to 30% higher HTCs than those of HCFC22 due to their excellent thermophysical properties. Propylene, propane, isobutane, and butane showed similar or lower HTCs than those of HCFC22. Beatty and Katz' correlation predicted the HTCs of the flammable refrigerants obtained on a low fin tube within a mean deviation of 7.3%. Turbo-C tube showed the best performance due to its 3 dimensional surface geometry for fast removal of condensate

  12. Oxidative stability of cnicken thigh meat after treatment of abies alba essential oil

    Directory of Open Access Journals (Sweden)

    Adriana Pavelková

    2015-12-01

    Full Text Available In the present work, the effect of the Abies alba essential oil in two different concentrations on oxidative stability of chicken thigh muscles during chilled storage was investigated. In the experiment were chickens of hybrid combination Cobb 500 after 42 days of the fattening period slaughtered.  All the broiler chickens were fed with the same feed mixtures and were kept under the same conditions. The feed mixtures were produced without any antibiotic preparations and coccidiostatics. After slaughtering was dissection obtained fresh chicken thigh with skin from left half-carcass which were divided into five groups (n = 5: C - control air-packaged group; A1 - vacuum-packaged experimental group; A2 - vacuum-packaged experimental group with ethylenediaminetetraacetic acid (EDTA solution 1.50% w/w; A3 - vacuum-packaged experimental group with Abies alba oil 0.10% v/w and A4 - vacuum-packaged experimental group with Abies alba oil 0.20% v/w. The Abies alba essential oil was applicate on ground chicken things and immediately after dipping, each sample was packaged using a vacuum packaging machine and storage in refrigerate at 4 ±0.5 °C. Thiobarbituric acid (TBA value expressed in number of malondialdehyde was measured in the process of first storage day of 1st, 4th, 8th, 12th and 16th day after slaughtering and expressed on the amount of malondialdehyde (MDA in 1 kg sample. The treatments of chicken things with Abies alba essential oil show statistically significant differences between all testing groups and control group, where higher average value of MDA measured in thigh muscle of broiler chickens was in samples of control group (0.4380 mg.kg-1 compared to experimental groups A1 (0.124 mg.kg-1, A2 (0.086 mg.kg-1, A3 (0.082 mg.kg-1 and A4 (0.077 mg.kg-1 after 16-day of chilled storage. Experiment results show that the treatment of chicken thigh with Abies alba essential oil positively influenced on the reduction of oxidative processes in thigh

  13. Effectiveness of Indonesian Essential Oil Mixture of Lemongrass, Cananga, and Patchouli in Relaxation through Inhalation: A Clinical Test on Healthy Woman with High Potential for Stress

    Directory of Open Access Journals (Sweden)

    Richard Siahaan

    2014-12-01

    Full Text Available Relaxation is one of many mechanisms for coping with stress. One of the most widely used methods for relaxation is aromatherapy with the application of essential oils. Known for their therapeutic benefits, essential oils can be extracted from various Indonesian native herbs such as lemongrass (sereh wangi or Cymbopogon winterianus, cananga or ylang-ylang (kenanga or Canarium odoratum, and patchouli (nilam or Pogostemon cabin. This study aims to examine the effectiveness of a mixture of Indonesian essential oil made of lemongrass, cananga, and patchouli extracts. Experiment was conducted by asking a number of subjects to inhale the oil mixture and assessing its effectiveness in terms of psychological relaxation by using Visual Analog Scale or VAS and of physical relaxation by examining the subjects’ blood pressure (MAP, pulse frequency, and breathing frequency. The result was then compared with that of lavender oil and with the control group. The study was conducted on 60 healthy women through single-blind clinical trials (before and after using the “intent to treat” approach, followed by a startle test. Participants were divided into three groups: (1 20 participants who were treated with Indonesian essential oil mixture, (2 20 participants who were treated with lavender oil, and (3 20 participants who served as the control group. Psychological relaxation measurement showed that Indonesian essential oil mixture produced the same degree of effectiveness as lavender oil and the control groups did, although both treatments tended to produce better results than the control group did. However, physical relaxation measurement showed that Indonesian essential oil mixture produced a higher degree of effectiveness than lavender oil and tended to produce a better result than the control group did, especially in terms of blood pressure based on MAP scores.

  14. A Weibull model to describe antimicrobial kinetics of oregano and lemongrass essential oils against Salmonella Enteritidis in ground beef during refrigerated storage.

    Science.gov (United States)

    de Oliveira, Thales Leandro Coutinho; Soares, Rodrigo de Araújo; Piccoli, Roberta Hilsdorf

    2013-03-01

    The antimicrobial effect of oregano (Origanum vulgare L.) and lemongrass (Cymbopogon citratus (DC.) Stapf.) essential oils (EOs) against Salmonella enterica serotype Enteritidis in in vitro experiments, and inoculated in ground bovine meat during refrigerated storage (4±2 °C) for 6 days was evaluated. The Weibull model was tested to fit survival/inactivation bacterial curves (estimating of p and δ parameters). The minimum inhibitory concentration (MIC) value for both EOs on S. Enteritidis was 3.90 μl/ml. The EO concentrations applied in the ground beef were 3.90, 7.80 and 15.60 μl/g, based on MIC levels and possible activity reduction by food constituents. Both evaluated EOs in all tested levels, showed antimicrobial effects, with microbial populations reducing (p≤0.05) along time storage. Evaluating fit-quality parameters (RSS and RSE) Weibull models are able to describe the inactivation curves of EOs against S. Enteritidis. The application of EOs in processed meats can be used to control pathogens during refrigerated shelf-life. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Antioxidant Activity of Potato Peel Extracts in a Fish-RapeseedOil Mixture and in Oil-in-Water Emulsions

    DEFF Research Database (Denmark)

    Farvin, Sabeena; Nielsen, Nina Skall; Jacobsen, Charlotte

    2010-01-01

    The objectives of the present work were (a) to extract the phenolic fraction from the peels of two Danish varieties of potatoes, viz. Sava and Bintje, and examine their antioxidant capacity in in-vitro systems (b) to evaluate the effect of these extracts on the storage stability of a fish- rapeseed...... oil mixture and oil-in-water emulsions. Multiple antioxidant activity of the potato peel extracts was evident from in-vitro systems as they showed strong reducing power, radical scavenging ability, ferrous ion chelating activity and prevented oxidation in a liposome model system. The Sava variety...... in emulsions. Thus, the results of the present study show the possibility of utilizing waste potato peel as a promising source of natural antioxidants for retarding lipid oxidation....

  16. Evaluation of a diesel engine running with stationary mixtures of soybean oil and reused oil diesel; Avaliacao de um motor diesel estacionario funcionando com misturas de oleo de soja reutilizado e oleo diesel

    Energy Technology Data Exchange (ETDEWEB)

    Maronhas, Maite E.S.; Fernandes, Haroldo C.; Siqueira, Wagner C.; Figueiredo, Augusto C. [Universidade Federal de Vicosa (UFV), MG (Brazil)], Emails: maronhas@gmail.com, haroldo@ufv.br, augusto.figueiredo@ufv.br

    2009-07-01

    The tests were conducted at the Laboratory of Agricultural Mechanization Department of Agricultural Engineering, Federal University of Vicosa using a stationary diesel engine Yanmar brand NS{sub B} 75, with nominal power of 5.8 kw at 2400 rpm, direct injection, and water cooled. This work aimed to examine the reuse of soybean oil to drive the engine stationary. Were used as fuel five mixtures of diesel oil (DO) and soybean oil (OS) re-used in the kitchen of the restaurant of the university in the proportions of 0-100%, 25-75%, 50-50%, 75-25 % and 100-0% respectively. The power and torque of the engine is higher for the mixture showed a 75% OD and 25% OS and 25% lower for DO and 75% OS. The lowest hourly consumption was with a mixture of 25% and 75% OD and OS was 15% lower than for the pure diesel. The values found justifying the use of mixtures of diesel and soybean oil reused, but the technical aspects, especially regarding the wear of the engine, must be evaluated to indicate the use after a long period of engine operation. (author)

  17. Carbon dioxide R744 as a refrigerant in automotive air-conditioning systems; Kohlendioxid-R744 als Kaeltemittel in Fahrzeug-Klimaanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, P.; Graz, M.; Obrist, F. [Obrist Engineering GmbH (Germany); Parsch, W. [LuK Fahrzeug-Hydraulik GmbH und Co. KG (Germany); Rinne, F. [Sanden Technical Center (Europe) GmbH (Germany)

    2001-12-01

    Toyota's announcement that they are to use environmentally friendly, high-performance air-conditioning systems based on the refrigerant R744 as from the year 2003 confirms a world-wide trend. German competitors documented their development achievements in this area during the course of SAE conferences in Phoenix during the period 1998 to 2000. The authors who contributed to the present article come from LuK/Sanden and Obrist Engineering, both of which work closely with Audi, BMW, DaimlerChrysler, Volkswagen and their suppliers to develop components and processes. (orig.) [German] Die Ankuendigung von Toyota, umweltfreundliche und leistungsfaehige Klimaanlagen mit dem Kaeltemittel R744 ab 2003 serienmaessig einzusetzen, bestaetigt einen weltweiten Trend. Auch die deutschen Wettbewerber haben - unter anderem im Verlauf von SAE-Veranstaltungen in Phoenix in den Jahren 1998 bis 2000 - ihre Entwicklungsleistungen auf diesem Gebiet dokumentiert. Das Autorenteam besteht aus Mitarbeitern der Firmen LuK/Sanden und Obrist Engineering, die in enger Zusammenarbeit mit Audi, BMW, DaimlerChrysler, Volkswagen und deren Zulieferern Komponenten und Prozesse fuer zukuenftige Klimaanlagen entwickeln. (orig.)

  18. Commissioning and operational results of helium refrigeration system at JLab for the 12GeV upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Knudsen, Peter N. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Ganni, Venkatarao [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Dixon, Kelly D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Norton, Robert O. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Creel, Jonathan D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2015-12-01

    The new 4.5 K refrigerator system at the Jefferson Lab (JLab) Central Helium Liquefier (CHL-2) for the 12 GeV upgrade was commissioned in late spring of 2013, following the commissioning of the new compressor system, and has been supporting 12 GeV LINAC commissioning since that time. Six design modes were tested during commissioning, consisting of a maximum capacity, nominal capacity, maximum liquefaction, maximum refrigeration, maximum fill and a stand-by/reduced load condition. The maximum capacity was designed to support a 238 g/s, 30 K and 1.16 bar cold compressor return flow, a 15 g/s, 4.5 K liquefaction load and a 12.6 kW, 35-55 K shield load. The other modes were selected to ensure proper component sizing and selection to allow the cold box to operate over a wide range of conditions and capacities. The cold box system is comprised of two physically independent cold boxes with interconnecting transfer-lines. The outside (upper) 300-60 K vertical cold box has no turbines and incorporates a liquid nitrogen pre-cooler and 80-K beds. The inside (lower) 60-4.5 K horizontal cold box houses seven turbines that are configured in four expansion stages including one Joule-Thompson expander and a 20-K bed. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will summarize the analysis of the test data obtained over the wide range of operating conditions and capacities which were tested.

  19. A new human IgG avidity test, using mixtures of recombinant antigens (rROP1, rSAG2, rGRA6), for the diagnosis of difficult-to-identify phases of toxoplasmosis.

    Science.gov (United States)

    Drapała, Dorota; Holec-Gąsior, Lucyna; Kur, Józef; Ferra, Bartłomiej; Hiszczyńska-Sawicka, Elżbieta; Lautenbach, Dariusz

    2014-07-01

    The preliminary diagnostic utility of two mixtures of Toxoplasma gondii recombinant antigens (rROP1+rSAG2 and rROP1+rGRA6) in IgG ELISA and IgG avidity test has been evaluated. A total of 173 serum samples from patients with toxoplasmosis and seronegative people were examined. The sensitivity of IgG ELISA for rROP1+rSAG2 and rROP1+rGRA6 was 91.1% and 76.7%, respectively, while the reactivity for sera from patients where acute toxoplasmosis was suspected was higher, at 100% and 95.4%, respectively, than for people with chronic infection, at 88.2% and 70.6%. In this study a different trend in avidity maturation of IgG antibodies for two mixtures of proteins in comparison with native antigen was observed. The results suggest that a new IgG avidity test using the mixtures of recombinant antigens may be useful for the diagnosis of difficult-to-identify phases of toxoplasmosis. For this reason, selected mixtures after the additional tests on groups of sera with well-defined dates of infection could be used as a better alternative to the native antigens of the parasite in the serodiagnosis of human T. gondii infection. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Closed Cycle Solar Refrigeration with the Calcium Chloride System ...

    African Journals Online (AJOL)

    A closed cycle solid absorption intermittent refrigerator, using CaC12 absorbent and NH3 refrigerant, was constructed and tested to obtain the instantaneous and cumulative available overall COP. The combined collector/absorber/generator unit had double glazing of 1.14 m2 exposed areas. The system was fitted with a ...

  1. Energetic, Exergetic and Exergoeconomic Analysis of CO2 Refrigeration Systems Operating in Hot Climates

    DEFF Research Database (Denmark)

    Gullo, Paride; Elmegaard, Brian; Cortella, Giovanni

    2015-01-01

    of the product of a R744 refrigeration solution with auxiliary compressor with those of a R744 conventional system, both of them operating in transcritical conditions. The results pointed out that the adoption of an auxiliary compressor resulted in an increase of the COP by approximately 18.7% over...... conditions. CO2 refrigeration system with parallel compression represents one of the solutions which have been proposed in the last few years in order to enhance the performance of a single-stage refrigeration system. The main target of this study is to compare the thermodynamic efficiency and the final cost...

  2. Falling R and D but stable investments by oil companies, why? A study on R and D and investment in fixed assets in the oil industry

    International Nuclear Information System (INIS)

    Creusen, H.; Minne, B.

    2000-04-01

    In the last decade the world-wide research expenditures of the major oil companies have dropped. This is remarkable since their investments in fixed assets remained stable. This study reveals that the level of fixed investments particularly depend on their financial strength, while R and D mainly relates to competitors' research and common expectations. The decline in R and D is initiated by common expectations. In the mature oil industry, companies foresee diminishing research potential within the current technology. This is also confirmed by the declining number of patent applications. The high risks of research on renewable energy may lead to wait and see behaviour instead of new research initiatives. Actually, oil companies have hardly applied for patents on renewable energy. The R and D decline is intensified by a dwindling R and D-race, which is due to a large overlap in research topics. The companies protect their research results because they largely compete on their unique technologies which embody their research results. The research overlap appears from patents: the oil companies apply for patents in exactly the same patent classes. 19 refs

  3. Manufacturing A Refrigerator with Heat Recovery Unit

    Directory of Open Access Journals (Sweden)

    Mustafa Mohammed Kadhim

    2018-02-01

    Full Text Available This study aims to exploite the rejected heating energy from condenser and benefit from it to reheat the foods and other materials. It can also be employed to improve the coefficient of performance of a refrigerator at the same time by using approximately the same consumption electrical energy used to operate the compressor and refrigerator in general. This idea has been implemented by manufacturing of a refrigerator with using additional part has the same metal and condenser pipe diameters but its surface area does not exceed 40% from total surface area of the condenser and its design as an insulated cabinet from all sides to prevent heat leakage through it and located between the compressor and the condenser. Small electrical fan has been added inside this cabinet to provide a suitable air circulation and a homogenous temperature distribution inside the cabinet space. It is expected that the super heating energy of refrigerant (R134a which comes out of the compressor would be removed  inside this cabinet and this insist to condensate the refrigerant (cooling fluid with a rate higher than that used in the normal refrigerator only. Three magnetic valves have been used in order to control the refrigerant flow in state of operation the refrigerator only or to gather with heating cabinet. To measure the temperatures at each process of the simple vapor compression refrigeration cycle, nine temperature sensors at input and output of each compressor, condenser and an evaporator in additional to input of cabinet and inside it and on evaporator surface have been provided. Five pressure gages have been used to measure the value of pressure and compare it for the two states of operation. The consumption of electrical energy  can be calculated by adding an ammeter and a voltmeter and compare between the consumption energy of both states. The obtained results show that there is an improvement in the coeffecient of performance in state of operation the

  4. Compressor Calorimeter Test of R-410A Alternatives R-32, DR-5, and L-41a

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S [ORNL; Mahderekal, Isaac [ORNL; Sharma, Vishaldeep [ORNL; Abdelaziz, Omar [ORNL

    2013-02-01

    As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares performance of alternative refrigerants R32, DR-5, and L-41A to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. Compressor calorimeter tests were performed to evaluate the performance of the lower-GWP alternative refrigerants in place of the common refrigerant R-410A in a 36,000 Btu/hr compressor calorimeter using a compressor having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10 F to 55 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat and 65 F suction temperature. A liquid subcooling level of 15 F was maintained for all the test conditions. The tests showed that performance of these three lower-GWP alternative refrigerants is comparable to that of R-410A. For the 20 F superheat and 15 F subcooling test conditions, EERs of R32, DR-5, and L-41A were 90% to 99%, 96% to 99%, and 94% to 101%, respectively, compared to that of R-410A. Similarly, cooling capacities of R32, DR-5, and L-41A were 98% to 103%, 92% to 96%, and 84% to 92%, respectively, compared to that of R-410A.

  5. THERMODYNAMIC ANALYSIS AND SIMULATION OF A NEW COMBINED POWER AND REFRIGERATION CYCLE USING ARTIFICIAL NEURAL NETWORK

    Directory of Open Access Journals (Sweden)

    Hossein Rezvantalab

    2011-01-01

    Full Text Available In this study, a new combined power and refrigeration cycle is proposed, which combines the Rankine and absorption refrigeration cycles. Using a binary ammonia-water mixture as the working fluid, this combined cycle produces both power and refrigeration output simultaneously by employing only one external heat source. In order to achieve the highest possible exergy efficiency, a secondary turbine is inserted to expand the hot weak solution leaving the boiler. Moreover, an artificial neural network (ANN is used to simulate the thermodynamic properties and the relationship between the input thermodynamic variables on the cycle performance. It is shown that turbine inlet pressure, as well as heat source and refrigeration temperatures have significant effects on the net power output, refrigeration output and exergy efficiency of the combined cycle. In addition, the results of ANN are in excellent agreement with the mathematical simulation and cover a wider range for evaluation of cycle performance.

  6. EXTRACTION AND PARTIAL CHARACTERISATION OF PHYTOSTEROL FROM ETHANOLYSIS REACTION MIXTURE OF OIL DEODERISER DISTILLATES

    DEFF Research Database (Denmark)

    Panpipat, Worawan; Xu, Xuebing; Guo, Zheng

    Various plants and plant products (e.g. vegetable oil) are the major sources of phytosterols. Phytosterols are naturally occurring in either free form, or esters of fatty acids or glycoside forms, depending on their natural sources. As a potential industrial product, the main source is from...... deodoriser distillate (DOD) which is a by-product of oil refinery. Major applications of phystosterols are used as a functional food additive and a building block. Phytosterols are found to have cholesterol lowering effect by the inhibition of cholesterol absorption in the intestine lumen. As a building...... block, phytosteryl derivatives can be developed and introduced to pharmaceutical and cosmetic industries. Recently, we have successfully converted phytosteryl ester from industrial rapeseed and soybean oil DOD ethanolysed mixture to free phytosterols by using enzymatic transesterification. This study...

  7. General review of solar-powered closed sorption refrigeration systems

    International Nuclear Information System (INIS)

    Sarbu, Ioan; Sebarchievici, Calin

    2015-01-01

    Highlights: • Provide review of development in solar sorption refrigeration technologies. • Theoretical basis and applications of absorption and adsorption cycles are discussed. • Thermodynamic properties of most common working pairs have been reviewed. • Development of hybrid or thermal energy storage adsorption systems was explored. • A comparison between solar-powered absorption and adsorption systems was performed. - Abstract: The negative environmental impacts of burning fossil fuels have forced the energy research community seriously to consider renewable sources, such as naturally available solar energy. Thermally powered refrigeration technologies are classified into two categories: thermo-mechanical technology and sorption technology (open systems or closed systems). This paper provides a detailed review of the solar closed sorption (absorption and adsorption) refrigeration systems, which utilise working pairs (fluids). After an introduction of the basic principles of these systems, the history of development and recent advances in solar sorption refrigeration technologies are reported. The adsorption cooling typically has a lower heat source temperature requirement than the absorption cooling. Based on the coefficient of performance (COP), the absorption systems are preferred over the adsorption systems, and the higher temperature issues can be easily handled with solar adsorption systems. The thermodynamic properties of most common working fluids, as well as the use of ternary mixtures in solar-powered absorption systems, have been reviewed in this study. The paper also refers to new approaches to increase the efficiency and sustainability of the basic adsorption cycles, such as the development of hybrid or thermal energy storage adsorption systems. This research shows that solar-powered closed sorption refrigeration technologies can be attractive alternatives not only to serve the needs for air-conditioning, refrigeration, ice making, thermal

  8. Computation of thermophysical properties of working fluids in refrigerating and air conditioning systems

    International Nuclear Information System (INIS)

    Ciconkov, Risto; Tuneski, Nikola

    2003-01-01

    A survey of the refrigerants and international regulations concerning the Montreal Protocol and the Kyoto Protocol is given. The necessity of their thermophysical properties: density (specific volume), specific heat, thermal conductivity and viscosity for calculation of heat exchangers (evaporators and condensers) is explained. The existing polynomial approximations of saturated thermophysical properties of the refrigerant R407C are presented. Further, the basic principles of the least squares method with an emphasize on the approximation with a polynomial of two variables are elaborated. An application of the method for obtaining a polynomial approximation of the thermophysical properties for the refrigerants R404A and R407C in the superheated area using the MatchCAD software is made. At the end the obtained approximations are discussed regarding to the deviations between the input data and the results. (Author)

  9. Magnetic refrigerator for hydrogen liquefaction

    Energy Technology Data Exchange (ETDEWEB)

    Numazawa, T [National Institute for Materials Science, Tsukuba (Japan); Kamlya, K. [Japan Atomic Energy Agency, Naka (Japan); Utaki, T. [Osaka University, Osaka (Japan); Matsumoto, K. [Kanazawa University, Kanazawa (Japan)

    2013-06-15

    This paper reviews the development status of magnetic refrigeration system for hydrogen liquefaction. There is no doubt that hydrogen is one of most important energy sources in the near future. In particular, liquid hydrogen can be utilized for infrastructure construction consisting of storage and transportation. Liquid hydrogen is in cryogenic temperatures and therefore high efficient liquefaction method must be studied. Magnetic refrigeration which uses the magneto-caloric effect has potential to realize not only the higher liquefaction efficiency > 50 %, but also to be environmentally friendly and cost effective. Our hydrogen magnetic refrigeration system consists of Carnot cycle for liquefaction stage and AMR (active magnetic regenerator) cycle for precooling stages. For the Carnot cycle, we develop the high efficient system > 80 % liquefaction efficiency by using the heat pipe. For the AMR cycle, we studied two kinds of displacer systems, which transferred the working fluid. We confirmed the AMR effect with the cooling temperature span of 12 K for 1.8 T of the magnetic field and 6 second of the cycle. By using the simulation, we estimate the total efficiency of the hydrogen liquefaction plant for 10 kg/day. A FOM of 0.47 is obtained in the magnetic refrigeration system operation temperature between 20 K and 77 K including LN2 work input.

  10. Study of extraction of rare earths by oil sulfoxides and their mixtures with tributyl phosphate

    International Nuclear Information System (INIS)

    Mikhlin, E.B.; Vol'dman, G.M.; Zelikman, A.N.; Novikova, N.N.

    1977-01-01

    Neodymium distribution is studied during its extraction from nitrate solutions with oil sulphoxides (OSO) and their mixtures with TBP in a wide range of neodymium and desalting agent (aluminium nitrate) concentrations. The extraction capacity of OSO is shown to considerably exceed that of TBP. A synergic effect due to formation of mixed solvates is observed at extraction with an OSO-TBP mixture. The separation coefficients (β) of the pairs Ce-La, Pr-Ce and Nd-Pr are determined. OSO and, especially, the OSO-TBP mixture are shown to be applicable for separating cerium and lanthanum, since the βsub(Ge/La) value for these extraction agents is higher than that for TBP, the extraction agent capacity attaining values that are acceptable for practival purposes

  11. Microbiological quality and other characteristics of refrigerated chicken meat in contact with cellulose acetate-based film incorporated with rosemary essential oil

    Directory of Open Access Journals (Sweden)

    Adriane Alexandre Machado de Melo

    2012-12-01

    Full Text Available Antimicrobial active packaging delays or inhibits microorganism growth in packed products, and it can be used in a variety of food systems. The objective of the present research was to develop packaging incorporated with natural antimicrobial agents (active film. The effects of the active film on the spoilage, pathogenic microorganism counts, pH and color of the refrigerated chicken breast cuts were analyzed. Cellulose acetate-based active films incorporating two concentrations (20% and 50%, v/w of rosemary (Rosmarinus officinalis L. essential oil were manufactured and placed in contact with the chicken breast cuts for six days. An analysis of variance and mean comparison tests (Tukey's test, p<0.05 were performed on the results. The films that contained 20% essential oil and were intercalated with chicken breast samples did not demonstrate significant effects on the control of psychrotrophic or total coliform microorganisms during the storage period; however, the films incorporated with 50% essential oil demonstrated efficacy toward the control of coliforms during the storage of the samples (6 days, 2 ± 2ºC. The pH was related to the psychrotrophic microorganism count and was not influenced by the treatment. The color was not influenced by the time of storage or the treatment. The results demonstrate that active films incorporating 50% rosemary essential oil are effective at controlling certain microorganisms in chicken breast cuts.

  12. The construction of a Pomeranchuk cell driven by a 4He-circulating dilution refrigerator and some related experiments

    International Nuclear Information System (INIS)

    Brandt, B. van den.

    1981-01-01

    This thesis deals with some investigations at very low temperatures in which a 4 He-circulating 3 He- 4 He dilution refrigerator and a Pomeranchuk cooling device are used. The main theme is the design and construction of a special device, a Pomeranchuk cell that is precooled and pressurized with a 4 He-circulating 3 He- 4 He dilution refrigerator, that can be used to obtain a lowest temperature of the order of 1.1 mK. Furthermore, some details of the working of such a dilution refrigerator and some properties of 3 He- 4 He mixtures at high pressures were investigated. (Auth.)

  13. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study.

    Science.gov (United States)

    Haidari, Leila A; Brown, Shawn T; Wedlock, Patrick; Connor, Diana L; Spiker, Marie; Lee, Bruce Y

    2017-04-19

    Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. Copyright © 2017. Published

  14. Portable refrigerant charge meter and method for determining the actual refrigerant charge in HVAC systems

    Science.gov (United States)

    Gao, Zhiming; Abdelaziz, Omar; LaClair, Tim L.

    2017-08-08

    A refrigerant charge meter and a method for determining the actual refrigerant charge in HVAC systems are described. The meter includes means for determining an optimum refrigerant charge from system subcooling and system component parameters. The meter also includes means for determining the ratio of the actual refrigerant charge to the optimum refrigerant charge. Finally, the meter includes means for determining the actual refrigerant charge from the optimum refrigerant charge and the ratio of the actual refrigerant charge to the optimum refrigerant charge.

  15. Chromatographic and spectroscopic analysis of heavy crude oil mixtures with emphasis in nuclear magnetic resonance spectroscopy: A review

    International Nuclear Information System (INIS)

    Silva, Sandra L.; Silva, Artur M.S.; Ribeiro, Jorge C.; Martins, Fernando G.; Da Silva, Francisco A.; Silva, Carlos M.

    2011-01-01

    Graphical abstract: The chromatographic and spectroscopic techniques used to characterize heavy crude oils, although more focused in the nuclear magnetic resonance spectroscopy as the technique of choice, due to its capability to provide great information on the chemical nature of individual types of proton and carbon atoms in different and complex mixtures of crude oils are described. This review is based on 65 references and describes in a critical and interpretative ways the advantages of the NMR spectroscopy as a main technique to be used in crude oil refining industries that want to characterize crude oil fractions and the obtained refined products. Highlights: ► Chromatogrfaphic and spectroscopic techniques used to characterize heavy crude oils have been reviewed. ► This review describes in a critical and interpretative ways the advantages of the NMR spectroscopy as a main technique to be used in crude oil refining industries. ► The progress in the interpretation of the NMR spectra and of different multivariate data analyses and their potential in the identification and characterization of hydrocarbons and their physical and chemical properties have also been reviewed. - Abstract: The state of the art in the characterization of heavy crude oil mixtures is presented. This characterization can be done by different techniques, such as gas chromatography (GC), high performance liquid chromatography (HPLC), thin layer chromatography (TLC), infrared spectroscopy (IR), Raman spectroscopy, nuclear magnetic resonance (NMR) spectroscopy and mass spectrometry (MS). Nuclear magnetic resonance spectroscopy is the technique of choice due to its capability to provide information on the chemical nature of individual types of hydrogen and carbon atoms in different and complex mixtures of crude oils. The progress made in the interpretation of the NMR spectra with the development of new NMR techniques and different multivariate data analyses could give relevant

  16. Numerical and experimental study of the slug-flow regime in a mixture of castor and paraffin oils in a T-type microchannel

    Science.gov (United States)

    Minakov, A. V.; Shebeleva, A. A.; Yagodnitsyna, A. A.; Kovalev, A. V.; Bilsky, A. V.

    2017-09-01

    The slow-flug regime in a mixture of castor and paraffin oils in a T-type microchannel with crosssectional dimensions of 200 × 400 μm has been studied by numerical and experimental methods. The domain of existence of the slow-flug regime in this system has been determined. Dependence of the paraffin-oil slug length on the ratio of flow rates of the mixture components is established. Comparison of the calculated and experimental data shows their good agreement.

  17. Advanced Refrigerant-Based Cooling Technologies for Information and Communication Infrastructure (ARCTIC)

    Energy Technology Data Exchange (ETDEWEB)

    Salamon, Todd

    2012-12-13

    of a 100 kW prototype data center installation of the refrigerant-based modular cooling technology were dramatic in terms of energy efficiency and the ability to cool high-heat-density equipment. The prototype data center installation consisted of 10 racks each loaded with 10 kW of high-heat-density IT equipment with the racks arranged in a standard hot-aisle/cold-aisle configuration with standard cabinet spacing. A typical chilled-water CRAC unit would require approximately 16 kW to cool such a heat load. In contrast, the refrigerant-based modular cooling technology required only 2.3 kW of power for the refrigerant pump and shelf-level fans, a reduction of 85 percent. Differences in hot-aisle and cold-aisle temperature were also substantially reduced, mitigating many issues that arise in purely air-based cooling systems, such as mixing of hot and cold air streams, or from placing high-heat-density equipment in close proximity. The technology is also such that it is able to retro-fit live equipment without service interruption, which is particularly important to the large installed ICT customer base, thereby providing a means of mitigating reliability and performance concerns during the installation, training and validation phases of product integration. Moreover, the refrigerant used in our approach, R134a, is a widely-used, non-toxic dielectric liquid which, unlike water, is non-conducting and non-corrosive and will not damage electronics in the case of a leak a triple-play win over alternative water-based liquid coolant technologies. Finally, through use of a pumped refrigerant, pressures are modest (~60 psi), and toxic lubricants and oils are not required, in contrast to compressorized refrigerant systems another environmental win. Project Activities - The ARCTIC project goal was to further develop and dramatically accelerate the commercialization of this game-changing, refrigerant-based, liquid-cooling technology and achieve a revolutionary increase in energy

  18. Experimental studies on a vapour compression system using ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... The addition of nanoparticles to the refrigerant results in improvements in the ... reduces by 25% when POE oil is replaced by a mixture of mineral oil and alumina nanoparticles.

  19. Evaluation of thermal-hydraulic performance of hydrocarbon refrigerants during flow boiling in a microchannels array heat sink

    International Nuclear Information System (INIS)

    Chávez, Cristian A.; Leão, Hugo L.S.L.; Ribatski, Gherhardt

    2017-01-01

    Highlights: • Evaluation of refrigerants R600a, R290 and R1270 during flow boiling in a microchannels array. • Comparison of data for hydrocarbons with previous data for R134a. • Parametric analysis of heat transfer coefficient, pressure drop, ONB and exergy behaviors. • Comparison of the experimental data and prediction methods from literature. • In general, refrigerant R290 presents the best performance. - Abstract: The present study concerns an experimental evaluation of the performance of hydrocarbon refrigerants during flow boiling in a microchannels array heat sink. The heat sink is composed of fifty channels with cross sectional areas of 123 × 494 μm"2 and length of 15 mm manufactured in a copper block. Heat transfer coefficient and pressure drop data were obtained for refrigerants R600a, R290 and R1270, mass velocities from 165 to 823 kg/m"2 s, heat fluxes up to 400 kW/m"2, liquid subcooling at the inlet of the test section of 5, 10 and 15 °C and saturation temperature of 25 °C. The data were compared with experimental results obtained in a previous study for R134a and predictions by methods from literature. In general, R290 presented the best performance, providing the highest average heat transfer coefficient and a pressure drop only slightly higher than R1270 that was the fluid presenting the lowest pressure drop. An exergy analysis also revealed the refrigerant R290 as the one presenting the best performance. However, R290 needed the highest excess of superheating to trigger the boiling process (ONB). The methods from literature evaluated in the present study poorly predicted the experimental data for two-phase pressure drop. On the other hand, the method of Kanizawa et al. (2016) was quite accurate in predicting the heat transfer results.

  20. Assessment of commercially available energy-efficient room air conditioners including models with low global warming potential (GWP) refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Shah, N. K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, W. Y. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gerke, B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-30

    Improving the energy efficiency of room air conditioners (RACs) while transitioning to low global-warming-potential (GWP) refrigerants will be a critical step toward reducing the energy, peak load, and emissions impacts of RACs while keeping costs low. Previous research quantified the benefits of leapfrogging to high efficiency in tandem with the transition to low-GWP refrigerants for RACs (Shah et al., 2015) and identified opportunities for initial action to coordinate energy efficiency with refrigerant transition in economies constituting about 65% of the global RAC market (Shah et al., 2017). This report describes further research performed to identify the best-performing (i.e., most efficient and low-GWP-refrigerant using) RACs on the market, to support an understanding of the best available technology (BAT). Understanding BAT can help support market-transformation programs for high-efficiency and low-GWP equipment such as minimum energy performance standards (MEPS), labeling, procurement, and incentive programs. We studied RACs available in six economies—China, Europe, India, Japan, South Korea, and the United States—that together account for about 70% of global RAC demand, as well as other emerging economies. The following are our key findings: • Highly efficient RACs using low-GWP refrigerants, e.g., HFC-32 (R-32) and HC-290 (R-290), are commercially available today at prices comparable to similar RACs using high-GWP HCFC-22 (R-22) or HFC-410A (R-410A). • High efficiency is typically a feature of high-end products. However, highly efficient, cost-competitive (less than 1,000 or 1,500 U.S. dollars in retail price, depending on size) RACs are available. • Where R-22 is being phased out, high GWP R-410A still dominates RAC sales in most mature markets except Japan, where R-32 dominates. • In all of the economies studied except Japan, only a few models are energy efficient and use low-GWP refrigerants. For example, in Europe, India, and Indonesia

  1. The optimum intermediate pressure of two-stages vapor compression refrigeration cycle for Air-Conditioning unit

    Science.gov (United States)

    Ambarita, H.; Sihombing, H. V.

    2018-03-01

    Vapor compression cycle is mainly employed as a refrigeration cycle in the Air-Conditioning (AC) unit. In order to save energy, the Coefficient of Performance (COP) of the need to be improved. One of the potential solutions is to modify the system into multi-stages vapor compression cycle. The suitable intermediate pressure between the high and low pressures is one of the design issues. The present work deals with the investigation of an optimum intermediate pressure of two-stages vapor compression refrigeration cycle. Typical vapor compression cycle that is used in AC unit is taken into consideration. The used refrigerants are R134a. The governing equations have been developed for the systems. An inhouse program has been developed to solve the problem. COP, mass flow rate of the refrigerant and compressor power as a function of intermediate pressure are plotted. It was shown that there exists an optimum intermediate pressure for maximum COP. For refrigerant R134a, the proposed correlations need to be revised.

  2. Theoretical investigation of adiabatic capillary tubes working with propane/n-butane/iso-butane blends

    International Nuclear Information System (INIS)

    Fatouh, M.

    2007-01-01

    In this paper, a theoretical model is developed to predict the refrigerant flow characteristics in adiabatic capillary tubes using propane/n-butane/iso-butane mixtures as working fluids in a domestic refrigerator. This model is based on the mass, energy and momentum conservation equations for a homogeneous refrigerant flow under different inlet conditions, such as subcooled, saturated and two phase flow. The effects of the inlet pressure (8-16 bar), inlet vapor quality (0.001-15%), inlet subcooling degree (1-15 o C), mass flow rate (1-5 kg/h), propane mass fraction (0.5-0.7), capillary tube inner diameter (0.6-1.0 mm) and the tube surface roughness on the capillary tube length are predicted. The results showed that the present model predicts data that are very close to the available experimental data in the literature with an average error of 2.65%. The pressure of the hydrocarbon mixture (HCM) decreases, while its vapor quality, specific volume and Mach number increase along the capillary tube. Also, the results indicated that the capillary tube length is largely dependent on the capillary tube diameter. Other parameters such as mass flow rate, inlet pressure, subcooling degree (or quality) and relative roughness influence the capillary tube length in that order. The capillary tube length as a function of the significant parameters is presented in equation form. Also, capillary tube selection charts either to predict the mass flow rates of propane/n-butane/iso-butane mixtures through adiabatic capillary tubes or to select the capillary tube size according to the required applications are developed. The comparison between R12, R134a and the hydrocarbon mixture (HCM) of propane/n-butane/iso-butane indicated that for a given mass flow rate, the pressure drop per unit length is about 4.13, 5.0 and 12.0 bar/m for R12, R134a and HCM, respectively. The ratios of the average mass flow rate of the HCM with a propane mass fraction of 0.6 to those of R12 and R134a are about

  3. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study☆

    Science.gov (United States)

    Haidari, Leila A.; Brown, Shawn T.; Wedlock, Patrick; Connor, Diana L.; Spiker, Marie; Lee, Bruce Y.

    2017-01-01

    Background Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Methods Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as “electric refrigerators”) at different locations in the supply chain under various circumstances. Results At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Conclusion Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar

  4. Review of magnetic refrigeration system as alternative to conventional refrigeration system

    Science.gov (United States)

    Mezaal, N. A.; Osintsev, K. V.; Zhirgalova, T. B.

    2017-10-01

    The refrigeration system is one of the most important systems in industry. Developers are constantly seeking for how to avoid the damage to the environment. Magnetic refrigeration is an emerging, environment-friendly technology based on a magnetic solid that acts as a refrigerant by magneto-caloric effect (MCE). In the case of ferromagnetic materials, MCE warms as the magnetic moments of the atom are aligned by the application of a magnetic field. There are two types of magnetic phase changes that may occur at the Curie point: first order magnetic transition (FOMT) and second order magnetic transition (SOMT). The reference cycle for magnetic refrigeration is AMR (Active Magnetic Regenerative cycle), where the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. Regeneration can be accomplished by blowing a heat transfer fluid in a reciprocating fashion through the regenerator made of magnetocaloric material that is alternately magnetized and demagnetized. Many magnetic refrigeration prototypes with different designs and software models have been built in different parts of the world. In this paper, the authors try to shed light on the magnetic refrigeration and show its effectiveness compared with conventional refrigeration methods.

  5. Fuel conversion characteristics of black liquor and pyrolysis oil mixture for efficient gasification with inherent catalyst

    OpenAIRE

    Bach Oller, Albert; Furusjö, Erik; Umeki, Kentaro

    2014-01-01

    This paper describes the technical feasibility of a catalytic co-gasification process using a mixture of black liquor (BL) and pyrolysis oil (PO). A technical concern is if gasifiers can be operated at low temperature (~1000 ºC) without problems of tar, soot or char, as is the case for pure BL due to the catalytic effect of fuel alkali. Hence, we investigated fuel conversion characteristics of BL/PO mixture: conversion of single droplet in flame, and char gasification reactivity. 20wt.% (BP20...

  6. Substrate interactions in dehalogenation of 1,2-dichloroethane, 1,2-dichloropropane, and 1,1,2-trichloroethane mixtures by Dehalogenimonas spp.

    Science.gov (United States)

    Dillehay, Jacob L; Bowman, Kimberly S; Yan, Jun; Rainey, Fred A; Moe, William M

    2014-04-01

    When chlorinated alkanes are present as soil or groundwater pollutants, they often occur in mixtures. This study evaluated substrate interactions during the anaerobic reductive dehalogenation of chlorinated alkanes by the type strains of two Dehalogenimonas species, D. lykanthroporepellens and D. alkenigignens. Four contaminant mixtures comprised of combinations of the chlorinated solvents 1,2-dichloroethane (1,2-DCA), 1,2-dichloropropane (1,2-DCP), and 1,1,2-trichloroethane (1,1,2-TCA) were assessed for each species. Chlorinated solvent depletion and daughter product formation determined as a function of time following inoculation into anaerobic media revealed preferential dechlorination of 1,1,2-TCA over both 1,2-DCA and 1,2-DCP for both species. 1,2-DCA in particular was not dechlorinated until 1,1,2-TCA reached low concentrations. In contrast, both species concurrently dechlorinated 1,2-DCA and 1,2-DCP over a comparably large concentration range. This is the first report of substrate interactions during chlorinated alkane dehalogenation by pure cultures, and the results provide insights into the chlorinated alkane transformation processes that may be expected for contaminant mixtures in environments where Dehalogenimonas spp. are present.

  7. Combustion of biodiesel fuel produced from hazelnut soapstock/waste sunflower oil mixture in a Diesel engine

    International Nuclear Information System (INIS)

    Usta, N.; Oeztuerk, E.; Can, Oe.; Conkur, E.S.; Nas, S.; Con, A.H.; Can, A.C.; Topcu, M.

    2005-01-01

    Biodiesel is considered as an alternative fuel to Diesel fuel No. 2, which can be generally produced from different kinds of vegetable oils. Since the prices of edible vegetable oils are higher than that of Diesel fuel No. 2, waste vegetable oils and non-edible crude vegetable oils are preferred as potential low priced biodiesel sources. In addition, it is possible to use soapstock, a by-product of edible oil production, for cheap biodiesel production. In this study, a methyl ester biodiesel was produced from a hazelnut soapstock/waste sunflower oil mixture using methanol, sulphuric acid and sodium hydroxide in a two stage process. The effects of the methyl ester addition to Diesel No. 2 on the performance and emissions of a four cycle, four cylinder, turbocharged indirect injection (IDI) Diesel engine were examined at both full and partial loads. Experimental results showed that the hazelnut soapstock/waste sunflower oil methyl ester can be partially substituted for the Diesel fuel at most operating conditions in terms of the performance parameters and emissions without any engine modification and preheating of the blends

  8. Evaluation of the use of a vegetable oil in distribution transformers

    OpenAIRE

    Fernando-Navas,Diego; Echeverry-Ibarra,Diego Fernando; Cadavid-Ramírez,Héctor

    2012-01-01

    Since the start of transformers immersed in refrigerating liquid, the fluid traditionally used has been mineral oil. However, in recent decades, efforts have been joined in the search for alternatives with a lower environmental impact and which also satisfy the technical requirements of insulation and refrigeration in the transformers. Currently, insulating vegetable oils are available in the market, which may have lower environmental impact during their use and final disposition; nevertheles...

  9. 非共沸混合冷媒R22+R114の水平な内面溝付き管内における凝縮および蒸発熱伝達

    OpenAIRE

    小山, 繁; 宮良, 明男; 高松, 洋; 米本, 和生; 藤井, 哲

    1987-01-01

    Experimental results of the condensation and evaporation of non-azeotropic refrigerant mixtures of R22 and R114 inside a horizontal tube with internal spiral grooves are presented. The test condenser and evaporator, which are of the same shape, are tube-in-tube counter flow type heat exchangers. The inner tube is made of copper with a geometry as follows: outer diameter 9.52mm, mean wall thickness 0.60mm, mean inner diameter 8.32mm, groove depth 0.15mm, number of grooves 60, lead angle of gro...

  10. Bioremediation of oil sludge contaminated soil using bulking agent mixture enriched consortia of microbial inoculants based by irradiated compost

    International Nuclear Information System (INIS)

    Tri Retno, D.L.; Mulyana, N.

    2013-01-01

    Bulking agent mixture enriched consortia of microbial inoculants based by irradiated compost was used on bioremediation of microcosm scale contaminated by hydrocarbon soil. Bioremediation composting was carried out for 42 days. Composting was done with a mixture of bulking agent (sawdust, residual sludge biogas and compost) by 30%, mud petroleum (oil sludge) by 20% and 50% of soil. Mixture of 80% soil and 20% oil sludge was used as a control. Irradiated compost was used as a carrier for consortia of microbial inoculants (F + B) which biodegradable hydrocarbons. Treatment variations include A1, A2, B1, B2, C1, C2, D1 and D2. Process parameters were observed to determine the optimal conditions include: temperature, pH, water content, TPC (Total Plate Count) and degradation of % TPH (Total Petroleum Hydrocarbon). Optimal conditions were achieved in the remediation of oil sludge contamination of 20% using the B2 treatment with the addition consortia of microbial inoculants based by irradiated compost of sawdust (bulking agentby 30% at concentrations of soil by 50% with TPH degradation optimal efficiency of 81.32%. The result of GC-MS analysis showed that bioremediation for 42 days by using a sawdust as a mixture of bulking agents which enriched consortia of microbial inoculants based by irradiated compost is biodegradeable, so initial hydrocarbons with the distribution of the carbon chain C-7 to C-54 into final hydrocarbons with the distribution of carbon chain C-6 to C-8. (author)

  11. Method and apparatus for recovering oil from an oil spill on the surface of a body of water

    International Nuclear Information System (INIS)

    Schweizer, R.W.; Patel, K.P.; Lau, P.Y.

    1991-01-01

    This patent describes a method of recovering a hydrophobic hydrocarbon oil from the surface of a body of water, the body of water having a water temperature, the oil having a specific gravity which is less than the specific gravity of the water in the body of water and a viscosity which is greater than approximately 80 centipoise at the water temperature. It comprises continuously withdrawing a feed oil-water mixture from the surface of the body of water; continuously adjusting the viscosity of the oil in the feed oil-water mixture to a level below approximately 80 centipoise to form an adjusted oil-water mixture; and continuously passing the adjusted oil-water mixture through an oil-water coalescer to separate the oil in the adjusted oil-water mixture from the water in the adjusted oil-water mixture

  12. PERFORMANCE ANALYSIS OF VCR SYSTEM WITH VARYING THE DIAMETERS OF HELICAL CONDENSER COIL BY USING R-134A REFRIGERANT

    OpenAIRE

    R.Hussain Vali; P.Yagnasri; S.Naresh Kumar Reddy

    2016-01-01

    Vapor compression machine is a refrigerator in which the heat removed from the cold by evaporation of the refrigerant is given a thermal potential so that it can gravitate to a natural sink by compressing the vapor produced. Majority of the refrigerators works on the Vapor compression refrigeration system. The system consists of components like compressor, condenser, expansion valve and evaporator. The performance of the system depends on the performance of all the components of the system. ...

  13. Oxidative stability of chicken’s breast after vacuum packaging, EDTA, sage and rosemary essential oils treatment

    Directory of Open Access Journals (Sweden)

    Adriana Pavelková

    2016-07-01

    Full Text Available In the present work, the effect of the sage and rosemary essential oils on oxidative stability of chicken breast muscles during chilled storage was investigated. In the experiment were chickens of hybrid combination Cobb 500 after 42 days of the fattening period slaughtered.  All the broiler chickens were fed with the same feed mixtures and were kept under the same conditions. The feed mixtures were produced without any antibiotic preparations and coccidiostats. After slaughtering was dissection obtained fresh chicken breast with skin from left half-carcass, which were divided into five groups (n = 5: C - control air-packaged group; A1 - vacuum-packaged experimental group; A2 - vacuum-packaged experimental group with EDTA solution 1.50% w/w; A3 - vacuum-packaged experimental group with Salvia officinalis L. oil 2.0% v/w and A4 - vacuum-packaged experimental group with Rosmarinus officinalis L. essential oil 2.0% v/w. The sage and rosemary essential oils were applicate on surface chicken breasts and immediately after dipping, each sample was packaged using a vacuum packaging machine and storage in refrigerate at 4  ±0.5 °C. The value of thiobarbituric acid (TBA expressed as amount of malondialdehyde (MDA in 1 kg sample was measured during storage in 1st, 4th, 8th, 12th and 16th day. The treatments of chicken breasts with sage and rosemary essential oils show statistically significant differences between all testing groups and control group, where higher average value of MDA measured in breast muscle of broiler chickens was in samples of control group (0.396 mg.kg-1 compared to experimental groups A1 (0.060 mg.kg-1, A2 (0.052 mg.kg-1, A3 (0.042 mg.kg-1 and A4 (0.041 mg.kg-1 after 16-day of chilled storage. The results of experiment showed that the treatment of chicken breast with sage and rosemary essential oils had positive effect on the decrease of oxidative processes in breast muscles during chilling storage and use of plant essential oils

  14. Optimization of Multi-layer Active Magnetic Regenerator towards Compact and Efficient Refrigeration

    DEFF Research Database (Denmark)

    Lei, Tian; Engelbrecht, Kurt; Nielsen, Kaspar Kirstein

    2016-01-01

    Magnetic refrigerators can theoretically be more efficient than current vapor compression systems and use no vapor refrigerants with global warming potential. The core component, the active magnetic regenerator (AMR) operates based on the magnetocaloric effect of magnetic materials and the heat r....... In addition, simulations are carried out to investigate the potential of applying nanofluid in future magnetic refrigerators.......Magnetic refrigerators can theoretically be more efficient than current vapor compression systems and use no vapor refrigerants with global warming potential. The core component, the active magnetic regenerator (AMR) operates based on the magnetocaloric effect of magnetic materials and the heat...... their Curie temperature. Simulations are implemented to investigate how to layer the FOPT materials for obtaining higher cooling capacity. Moreover, based on entropy generation minimization, optimization of the regenerator geometry and related operating parameters is presented for improving the AMR efficiency...

  15. Refrigeration and global warming

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    Some aspects of global warming in general, and the implications for refrigerants and refrigerator efficiency in particular, are briefly considered in a question and answer format. The concepts of Global Warming Potential (GWP) and Total Equivalent Warming Impact (TEWI) are explained. GWP is an index which allows a simple comparison to be make between the warming effects of different gases on a kg to kg basis relative to carbon. The GWP depends both on the lifetime of a substance in the atmosphere and its infra-red absorption capacity. The overall warming effect of operating a refrigeration system for its entire life is measured by its TEWI. Chloroflourocarbons (CFCs) which have been widely used as refrigerants are powerful greenhouse gases with high GWPs. Because of the bank of CFCs in refrigerating systems, their levels in the atmosphere are still increasing and it will be some time before refrigerant changes will be effective in reducing the warming effects of refrigerant releases. Hydrocarbons, hydroflourocarbons and ammonia all have a part to play as substitute refrigerants. Refrigerator efficiency is very important in terms of reducing CO 2 emissions. (UK)

  16. Effect of Replacing Pork Fat with Vegetable Oils on Quality Properties of Emulsion-type Pork Sausages

    OpenAIRE

    Lee, Hyun-Jin; Jung, Eun-Hee; Lee, Sang-Hwa; Kim, Jong-Hee; Lee, Jae-Joon; Choi, Yang-II

    2015-01-01

    This study was conducted to evaluate the quality properties of emulsion-type pork sausages when pork fat is replaced with vegetable oil mixtures during processing. Pork sausages were processed under six treatment conditions: T1 (20% pork fat), T2 (10% pork fat + 2% grape seed oil + 4% olive oil + 4% canola oil), T3 (4% grape seed oil + 16% canola oil), T4 (4% grape seed oil + 4% olive oil + 12% canola oil), T5 (4% grape seed oil + 8% olive oil + 8% canola oil), and T6 (4% grape seed oil + 12%...

  17. Energy and exergy analyses of a bi-evaporator compression/ejection refrigeration cycle

    International Nuclear Information System (INIS)

    Geng, Lihong; Liu, Huadong; Wei, Xinli; Hou, Zhonglan; Wang, Zhenzhen

    2016-01-01

    Highlights: • A bi-evaporator compression/ejection refrigeration cycle was studied experimentally. • Experiments were operated at the same external conditions and cooling capacities. • COP improvement was 16.94–30.59% higher than that of the conventional system. • The exergy efficiency of the R134a cycle was improved by 7.57–28.29%. - Abstract: Aiming to reduce the throttling loss in the vapor compression refrigeration cycle, a bi-evaporator compression/ejection refrigeration cycle (BCERC) using an ejector as the expansion device was experimentally investigated with R134a refrigerant. The effects of the compressor frequency and the operating conditions on the coefficient of performance (COP) and the amount of exergy destruction of each component were studied. The results were compared with that of the conventional vapor compression refrigeration cycle under the same external operating conditions and cooling capacities. Results showed that the refrigeration cycle with an ejector as the expansion device exhibited lower irreversibility for each component and total system in comparison with the conventional vapor compression refrigeration cycle. The COP and the exergy efficiency of the BCERC were higher than that of the conventional system. The COP and exergy efficiency improvements became more significant as the condenser water temperature increased, the evaporator water temperature decreased and the compressor frequency increased. In the BCERC with a constant frequency compressor, the COP and the exergy efficiency could be improved by 16.94–30.59%, 7.57–28.29%, respectively. The COP and the exergy efficiency of the BCERC with a variable frequency compressor could increase by around 32.64% and 23.32%, respectively.

  18. Fluorocarbon Adsorption in Hierarchical Porous Frameworks

    Energy Technology Data Exchange (ETDEWEB)

    Motkuri, Radha K.; Annapureddy, Harsha V.; Vijayakumar, M.; Schaef, Herbert T.; Martin, P F.; McGrail, B. Peter; Dang, Liem X.; Krishna, Rajamani; Thallapally, Praveen K.

    2014-07-09

    The adsorption behavior of a series of fluorocarbon derivatives was examined on a set of microporous metal organic framework (MOF) sorbents and another set of hierarchical mesoporous MOFs. The microporous M-DOBDC (M = Ni, Co) showed a saturation uptake capacity for R12 of over 4 mmol/g at a very low relative saturation pressure (P/Po) of 0.02. In contrast, the mesoporous MOF MIL-101 showed an exceptionally high uptake capacity reaching over 14 mmol/g at P/Po of 0.4. Adsorption affinity in terms of mass loading and isosteric heats of adsorption were found to generally correlate with the polarizability of the refrigerant with R12 > R22 > R13 > R14 > methane. These results suggest the possibility of exploiting MOFs for separation of azeotropic mixtures of fluorocarbons and use in eco-friendly fluorocarbon-based adsorption cooling and refrigeration applications.

  19. Partition behavior of virgin olive oil phenolic compounds in oil-brine mixtures during thermal processing for fish canning.

    Science.gov (United States)

    Sacchi, Raffaele; Paduano, Antonello; Fiore, Francesca; Della Medaglia, Dorotea; Ambrosino, Maria Luisa; Medina, Isabel

    2002-05-08

    The chemical modifications and partitioning toward the brine phase (5% salt) of major phenol compounds of extra virgin olive oil (EVOO) were studied in a model system formed by sealed cans filled with oil-brine mixtures (5:1, v/v) simulating canned-in-oil food systems. Filled cans were processed in an industrial plant using two sterilization conditions commonly used during fish canning. The partitioning of phenolic compounds toward brine induced by thermal processing was studied by reversed-phase high-performance liquid chromatographic analysis of the phenol fraction extracted from oils and brine. Hydroxytyrosol (1), tyrosol (2), and the complex phenolic compounds containing 1 and 2 (i.e., the dialdehydic form of decarboxymethyl oleuropein aglycon 3, the dialdehydic form of decarboxymethyl ligstroside aglycon 4, and the oleuropein aglycon 6) decreased in the oily phase after sterilization with a marked partitioning toward the brine phase. The increase of the total amount of 1 and 2 after processing, as well as the presence of elenolic acid 7 released in brine, revealed the hydrolysis of the ester bond of hydrolyzable phenolic compounds 3, 4, and 6 during thermal processing. Both phenomena (partitioning toward the water phase and hydrolysis) contribute to explain the loss of phenolic compounds exhibited by EVOO used as filling medium in canned foods, as well as the protection of n-3 polyunsaturated fatty acids in canned-in-EVOO fish products.

  20. Comparative study of irreversibilities in an aqua-ammonia absorption refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Ataer, O E [Gazi Univ., Ankara (TR). Mechanical Engineering Dept.; Gogus, Y [Middle East Technical Univ., Ankara (Turkey)

    1991-03-01

    Irreversibilities in components of an aqua-ammonia absorption refrigeration system (ARS) have been determined by second law analysis. The components of the ARS are as follows: condenser, evaporator, absorber, generator, pump, expansion valves, mixture heat exchanger and refrigerant heat exchanger. It is assumed that the ammonia concentration at the generator exit is, independent of the other parameters, equal to 0.999 and at the evaporator exit the gas is saturated vapour. Pressure losses between the generator and condenser, and the evaporator and absorber are taken into consideration. In the results the dimensionless exergy loss of each component, the exergetic coefficient of performance, the coefficient of performance and the circulation ratio are given graphically for each different generator, evaporator, condenser and absorber temperature. (author).

  1. COMPARISON OF THE QUALITY OF VEGETABLE OILS DESIGNED FOR THE FRYING FOOD

    Directory of Open Access Journals (Sweden)

    Ladislav Mura

    2012-12-01

    Full Text Available The object of the research was to investigate the quality of vegetable oils for cooking food. The analysis used two types of oils - oil Fritol and Promienna. Both oils were purchased commercially. Oil changes were observed at frying French fries. At the same changes were observed oil stored at room temperature and the temperature in the refrigerator. The determined parameters included the measurement of polar materials in oil with electronic device Testo 265 for measuring the quality of cooking oil. Determination of change in the texture of oil during the oil deterioration by device Texturometer TA.XT Plus and determination the peroxide value by STN EN ISO 3960:2007. The work is also evaluating the results of the studied parameters. In all compared cases based on the content of the TPM showed higher heat resistance oil Fritol and sample of oil stored in the refrigerator.doi:10.5219/210

  2. Cryogenic forced convection refrigerating system

    International Nuclear Information System (INIS)

    Klee, D.J.

    1988-01-01

    This patent describes the method of refrigerating products by contact with a refrigerating gas which comprises introducing product into a refrigeration zone, contacting the product with the refrigerating gas for a sufficient time to refrigerate it to the appropriate extent and removing the refrigerated product. The improvement for producing the refrigeration gas from a liquid cryogen such that essentially all of the liquid cryogen is fully vaporized before contacting the product comprises: (a) introducing the liquid cryogen, selected from the group consisting of liquid air and liquid nitrogen, at elevated pressure into an ejector as the motive fluid to accelerate a portion of a warm refrigerating gas through the ejector while mixing the cryogen and gas to effect complete vaporization of the liquid cryogen and substantial cooling of the portion of the refrigerating gas resulting in a cold discharge gas which is above the liquefaction temperature of the cryogen; (b) introducing the cold discharge gas into a forced circulation pathway of refrigerating gas and producing a cold refrigerating gas which contacts and refrigerates product and is then at least partially recirculated; (c) sensing the temperature of the refrigerating gas in the forced circulation pathway and controlling the introduction of liquid cryogen with regard to the sensed temperature to maintain the temperature of the discharge gas above the liquefacton temperature of the cryogen utilized

  3. Experiments during flow boiling of a R22 drop-in: R422D adiabatic pressure gradients

    International Nuclear Information System (INIS)

    Rosato, A.; Mauro, A.W.; Mastrullo, R.; Vanoli, G.P.

    2009-01-01

    R22, the HCFC most widely used in refrigeration and air-conditioning systems in the last years, is phasing-out. R422D, a zero ozone-depleting mixture of R125, R134a and R600a (65.1%/31.5%/3.4% by weight, respectively), has been recently proposed as a drop-in substitute. For energy consumption calculations and temperature control, it is of primary importance to estimate operating conditions after substitution. To determine pressure drop in the evaporator and piping line to the compressor, in this paper the experimental adiabatic pressure gradients during flow boiling of R422D are reported for a circular smooth horizontal tube (3.00 mm inner radius) in a range of operating conditions of interest for dry-expansion evaporators. The data are used to establish the best predictive method for calculations and its accuracy: the Moreno-Quiben and Thome method provided the best predictions for the whole database and also for the segregated data in the annular flow regime. Finally, the experimental data have been compared with the adiabatic pressure gradients of both R22 and its much used alternative R407C available in the literature.

  4. CO2LD: An innovation educational project for High Degree Professional Training in Refrigeration

    Directory of Open Access Journals (Sweden)

    Ramon Cabello Lopez

    2013-12-01

    Full Text Available Refrigeration is one of the technology sectors which has suffered most changes in the last twenty years, because of the negative impact of the fluids used in the refrigeration cycles, the refrigerants, due to their impact in the ozone layer and the promotion of the global warming. Due to the negative impacts of the fluids, the European Union has established several directives to restrict the use of refrigerant fluids, causing the need of adaptation of the sector to the new regulations. The adaptation of the refrigeration sector to the new regulations must be done by all agents involved, included the training and education of the future refrigeration technicians. To allow this, the project CO2LD has been developed to introduce the future technology in the High Degree Professional Training in Refrigeration. The objective of the project consisted on introducing more efficient and more sustainable refrigeration systems, R134a/CO2 cascade cycles, in the studies of High Degree Professional Training in Refrigeration, and create a collaborative framework among students, secondary-schools, refrigeration technicians, refrigeration companies and the University to facilitate the know-how transfer. This paper presents the objectives of the project, describes its development and analyses the main conclusions of it.

  5. Total Synthesis of (R, R, R)-gamma-Tocopherol through Cu-Catalyzed Asymmetric 1,2-Addition

    NARCIS (Netherlands)

    Wu, Zhongtao; Harutyunyan, Syuzanna R.; Minnaard, Adriaan J.

    2014-01-01

    Based on the asymmetric copper-catalyzed 1,2-addition of Grignard reagents to ketones, (R,R,R)--tocopherol has been synthesized in 36% yield over 12 steps (longest linear sequence). The chiral center in the chroman ring was constructed with 73% ee by the 1,2-addition of a phytol-derived Grignard

  6. Thermodynamic performance analysis of a vapor compression–absorption cascaded refrigeration system

    International Nuclear Information System (INIS)

    Jain, Vaibhav; Kachhwaha, S.S.; Sachdeva, Gulshan

    2013-01-01

    Highlights: • Study includes first and second law analysis with alternatives refrigerants. • Power consumption in cascaded system is 61% less than vapor compression system. • COP of compression system is improved by 155% with cascaded absorption system. • Condenser is more sensitive to external fluid temperature as compare to evaporator. - Abstract: In the present study, a thermodynamic model for cascaded vapor compression–absorption system (CVCAS) has been developed which consists of a vapor compression refrigeration system (VCRS) coupled with single effect vapor absorption refrigeration system (VARS). Based on first and second laws, a comparative performance analysis of CVCAS and an independent VCRS has been carried out for a design capacity of 66.67 kW. The results show that the electric power consumption in CVCAS is reduced by 61% and COP of compression section is improved by 155% with respect to the corresponding values pertaining to a conventional VCRS. However there is a trade-off between these parameters and the rational efficiency which is found to decrease to half of that for a VCRS. The effect of various operating parameters, i.e., superheating, subcooling, cooling capacity, inlet temperature and the product of effectiveness and heat capacitance of external fluids are extensively studied on the COP, total irreversibility and rational efficiency of the CVCAS. Besides, the performance of environment friendly refrigerants such as R410A, R407C and R134A is found to be almost at par with that of R22. Hence, all the alternative refrigerants selected herein can serve as potential substitutes for R22. Furthermore, it has been found that reducing the irreversibility rate of the condenser by one unit due to decrease in condenser temperature depicted approximately 3.8 times greater reduction in the total irreversibility rate of the CVCAS, whereas unit reduction in the evaporator’s irreversibility rate due to increase in evaporator temperature reduced

  7. CAViaR-based forecast for oil price risk

    International Nuclear Information System (INIS)

    Huang, Dashan; Yu, Baimin; Fabozzi, Frank J.; Fukushima, Masao

    2009-01-01

    As a benchmark for measuring market risk, value-at-risk (VaR) reduces the risk associated with any kind of asset to just a number (amount in terms of a currency), which can be well understood by regulators, board members, and other interested parties. This paper employs a new VaR approach due to Engle and Manganelli [Engle, R.F., Manganelli, S., 2004. CAViaR: Conditional Autoregressive Value at Risk by Regression Quantiles. Journal of Business and Economic Statistics 22, 367-381] to forecasting oil price risk. In doing so, we provide two original contributions by introducing a new exponentially weighted moving average CAViaR model and developing a mixed data regression model for multi-period VaR prediction. (author)

  8. Flammable refrigerants

    NARCIS (Netherlands)

    Gerwen, R.J.M. van; Verwoerd, M.; Oostendorp, P.A.

    1999-01-01

    Hydrocarbons are promising alternatives for CFC, HCFC and HFC refrigerants. Due to their flammable nature, safety aspects have to be considered carefully. The world-wide situation concerning acceptability and practical application of flammable refrigerants is becoming more and more complex and

  9. A comparison of R-22, R-134a, R-410a, and R-407c condensation performance in smooth and enhanced tubes: Part 1, Heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Eckels, S J; Tesene, B A

    1999-07-01

    Local and average heat transfer coefficients during condensation are reported for R-22, R-134a, R-410a, and R-407c in one smooth tube and three enhanced surface tubes. The test tubes included a 3/8 inch outer diameter smooth tube, a 3/8 inch outer diameter microfin tube, a 5/16 inch outer diameter microfin tube, and a 5/8 inch outer diameter microfin tube. The local and average heat transfer coefficients were measured over a mass flux range of 92,100 lb/ft{sup 2}{center_dot}h to 442,200 lb/ft{sup 2}{center_dot}h and at saturation temperatures of 104 F and 122 F. A comparison of the performance of the different refrigerants reveals that R-134a has the highest heat transfer performance followed by R-22 and R-410a, which have similar performances. In general, R-407c had the lowest performance of the refrigerants tested. The microfin tube more than doubles the heat transfer coefficient compared to the smooth tube for all refrigerants at the low mass fluxes, but only increases the heat transfer coefficients by 50% at the highest mass flux tested. The measured heat transfer coefficients are also compared with a number of correlations for condensation.

  10. Effects of Herbal Essential Oil Mixture as a Dietary Supplement on Egg Production in Quail

    Directory of Open Access Journals (Sweden)

    Metin Çabuk

    2014-01-01

    Full Text Available One hundred and eighty 7-week-old laying quail were fed various diets over a 12-week period. The diets included a control diet (without essential oil mixture (EOM or antibiotics (ANTs, a basal diet including EOM (24 mg/kg feed, and a basal diet including an ANT (avilamycin, 10 mg/kg feed. Each treatment comprised 4 replications with 4 cages (15 quail per cage, amounting to 60 quail per treatment group. Diets (in mash form and water were provided for ad libitum consumption. EOM consisted of 6 different essential oils derived from the following herbs: oregano (Origanum sp., laurel leaf (Laurus nobilis L., sage leaf (Salvia triloba L., myrtle leaf (Myrtus communis, fennel seeds (Foeniculum vulgare, and citrus peel (Citrus sp.. In comparison with the control diet, adding supplements such as EOM and ANTs to the basal diet increased egg production in quail (P<0.001. However, egg production was similar between EOM and ANT treatment groups. Moreover, there were no differences between the treatment groups with regard to egg weight. Feed intake was not affected by EOM or ANT supplementation, whereas feed conversion ratio was significantly improved by EOM and ANT supplementation. Thus, we concluded that EOM has beneficial effects as a dietary supplement on egg production and feed conversion ratio.

  11. Antibacterial activity of Ziziphora clinopodioides essential oil and nisin against Bacillus subtilis and Salmonella Typhimurium in commercial barley soup

    Directory of Open Access Journals (Sweden)

    Y. Shahbazi

    2017-03-01

    Full Text Available The objective of the current study was to evaluate the antibacterial activity of nisin (250 and 500 IU/mL, Ziziphora clinopodioides essential oil (0.1 and 0.2% and their combination against Bacillus subtilis and Salmonella Typhimurium in commercial barley soup during refrigerated storage. Based on our findings, the population of pathogens was reduced with the addition of the essential oil and nisin, increased concentration of the added antibacterial agents and the longer storage time of commercial barley soup. The group treated with the essential oil at 0.2% and nisin at 500 IU/mL showed the most rapid decrease in the number of S. Typhimurium and B. subtilis. By the end of seven and five days, populations of S. Typhimurium and B. subtilis in overall concentrations of the essential oil with nisin were totally inhibited, respectively. Our findings suggest the possibility of utilising commercial barley soup with a mixture of Z. clinopodioides essential oil and nisin for the reduction of B. subtilis and S. Typhimurium.

  12. Effect of the essential oil of Rosmarinus officinalis (L. on rooster sperm motility during 4°C short-term storage

    Directory of Open Access Journals (Sweden)

    L. Touazi

    2018-05-01

    Full Text Available Aim: This study aimed to investigate the protective effect of Rosmarinus officinalis (L. essential oil on rooster sperm motility during 4°C short-term storage. Materials and Methods: R. officinalis essential oil was analyzed using gas chromatography coupled to mass spectrometry to identify the active components. 10 of 45-week-old Hubbard commercial broilers were subjected to biweekly semen collections during 3 weeks. At each collection, sperm was pooled and divided into four aliquots and then diluted with Tris extender supplemented with 870, 87, or 8.7 μg/ml of R. officinalis essential oil, identified as treatments R, R5, and R10, respectively. Tris-based extender without any supplementation was considered as a control group. Diluted sperm was then stored at 4°C in the refrigerator and analyzed at 0, 6, 24, and 48 h using a computer-assisted sperm analyzer. Different semen parameters were measured including total motility, progressive motility, gametes velocities (straight line velocity [VSL], curvilinear velocity [VCL], and average path velocity [VAP], amplitude of the lateral head displacement [ALH], and beat-cross frequency [BCF]. Results: The phytochemical analysis of R. officinalis essential oil revealed the presence of 25 active components including seven major molecules: Camphor (18.88%, camphene (5.17%, 1,8-cineole (7.85%, β-thujene (13.66%, α-thujene (4.87%, chrysanthenone (12.05%, and β-cubenene (7.97%. The results showed a beneficial effect of R. officinalis essential oil on sperm cells motility, particularly when using the lowest concentrations, 8.7 and 87 μg/ml. Progressive motility and gametes velocities (VCL, VSL, and VAP, materializing the quality of gametes motility, showed highly statistically significant values (p<0.01 in 8.7 and 87 μg/ml treatments, especially from 6 h of storage at 4°C. Conversely, the highest concentration (870 μg/ml showed harmful effects with a total spermicidal activity after 24 h of storage

  13. Compatibility of refrigerants and lubricants with elastomers. Quarterly report, 1 October 1992--30 December 1992

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, G.R.; Seiple, R.H.

    1993-01-01

    The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

  14. Determination of hydrogen content of Jatropha biodiesel oil using neutron reflection technique

    International Nuclear Information System (INIS)

    Okunade, I. O.; Jonah, S. A.; Omede, M.

    2014-01-01

    Biofuel is an environmental-friendly alternative to fossil fuel and holds immense potential for the future energy needs of the country. Non-edible jatropha biodiesel oil has been identified as one of the suitable bio-fuel options. In this work, experimental measurements were performed to determine the total hydrogen content of jatropha oil and jatropha-synthetic diesel oil mixture. The work was carried out using a neutron reflection facility at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria. Jatropha oil and jatropha-synthetic diesel mixture were subjected to experimental measurements for the purpose of determining bulk hydrogen content using neutron reflection facility that had been previously calibrated using various hydrocarbon materials of known hydrogen content. The hydrogen content of the sample were subsequently determined using their measured neutron reflection coefficient values and calibration data. In general, results obtained indicate high hydrogen content range of 10.68-12.16wt% for jatropha oil and the various jatropha-synthetic diesel mixtures. The implication of this is that jatropha oil or jatrophal-synthetic diesel mixture can be used as alternative fuel to mitigate high carbon monoxide emission.

  15. Thermodynamic simulation for a vapour compression system using organic refrigerants; Simulacao termodinamica do ciclo de compressao a vapor utilizando fluidos refrigerantes organicos

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Francisco S.; Santos, Carlos A.C. dos [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil). Lab. de Energia Solar; Torres, Ednildo A.; Jesus, Marcos F. de [Universidade Federal da Bahia (UFBA), Salvador, BA (Brazil). Dept. de Engenharia Quimica. Lab. de Energia e Gas

    2004-07-01

    According to the Montreal protocol, it is foreseen a total retreat of CFCs and HCFCs in applications of refrigeration and air conditioning. Before this context, considerable attention has been used in the substitution of HCFC-22 (R22) in systems of air conditioning, where they appear as possible alternatives two HFCs (R407c and R410a) and two HCs (R290 and R600a). In this work, possibilities and problems for the use of these fluids as alternatives to R22 in equipment of refrigeration are discussed. Five refrigerants (R22, R407c, R410a, R290 and R600) are selected, computational simulations done and your characteristic in terms of thermodynamic cycles are shown. The obtained conclusion is that propane offers the best alternative for R22 in equipment of refrigeration, because this besides being energetically efficient, is environmentally acceptable. However, safety precautions due to your inflammability must be seriously taken into account. For some applications the substitution of the current fluids (halocarbons) by the hydrocarbons can be done without larger additional costs, but not in the general case. (author)

  16. Refrigerants and environment

    Science.gov (United States)

    Tsvetkov, O. B.; Laptev, Yu A.

    2017-11-01

    The refrigeration and air-conditioning industries are important sectors of the economy and represents about 15 % of global electricity consumptions. The chlorofluorocarbons also called CFCs are a class of refrigerants containing the halogens chlorine and/or fluorine on a carbon skeleton. Because of their environmental impact the Montreal Protocol was negotiated in 1987 to limit the production of certain CFCs and hydrochlirofluorocarbons (HCFCs) in developed and developing countries. The halogenated refrigerants are depleting the ozone layer also major contribution to the greenhouse effect. To be acceptable as a refrigerant a fluid must satisfy a variety of thermodynamic criteria and should be environment friendly with zero Ozone Depletion Potential and low Global Warming Potential. The perspective of a future phase down of HFCs is considered in this report taking into account a strategy for the phase out of HCFCs and perspective of choosing of various refrigerant followed by safety issues.

  17. Eco-Friendly Alternative Refrigeration Systems -R-ES-O-N-A-N--CE ...

    Indian Academy of Sciences (India)

    An electrical signal may be converted to acoustical (i.e. ... Thermoacoustic Refrigeration System. In a simple ... Tc and rejecting Wclste heat power Qh to a heat sink at T h. •. In .... use where eco-friendliness, simplicity, reliability or low cost is.

  18. First principles predictions of thermophysical properties of refrigerant mixtures.

    Science.gov (United States)

    Oakley, Mark T; Do, Hainam; Hirst, Jonathan D; Wheatley, Richard J

    2011-03-21

    We present pair potentials for fluorinated methanes and their dimers with CO(2) based on ab initio potential energy surfaces. These potentials reproduce the experimental second virial coefficients of the pure fluorinated methanes and their mixtures with CO(2) without adjustment. Ab initio calculations on trimers are used to model the effects of nonadditive dispersion and induction. Simulations using these potentials reproduce the experimental phase-coexistence properties of CH(3)F within 10% over a wide range of temperatures. The phase coexistence curve of the mixture of CH(2)F(2) and CO(2) is reproduced with an error in the mole fractions of both phases of less than 0.1. The potentials described here are based entirely on ab initio calculations, with no empirical fits to improve the agreement with experiment.

  19. Energy consumption and energy R and D in OECD: Perspectives from oil prices and economic growth

    International Nuclear Information System (INIS)

    Leng Wong, Siang; Chia, Wai-Mun; Chang, Youngho

    2013-01-01

    We estimate the short-run and long-run elasticities of various types of energy consumption and energy R and D to changes in oil prices and income of the 20 OECD countries over the period of 1980–2010 using the Nerlove partial adjustment model (NPAM). We find negative income elasticity for coal consumption but positive income elasticity for oil and gas consumption suggesting the importance of economic growth in encouraging the usage of cleaner energy from coal to oil and gas. By introducing time dummies into the regressions, we show that climatic mitigation policies are able to promote the usage of cleaner energies. Through the dynamic linkages between energy consumption and energy R and D, we find that fossil fuel consumption promotes fossil fuel R and D and fossil fuel R and D in turn drives its own consumption. Renewable energy R and D which is more responsive to economic growth reduces fossil fuel consumption and hence fossil fuel R and D. - Highlights: • Economic growth encourages the use of cleaner forms of energy. • Economic growth promotes renewable energy R and D. • Subsidies for renewable energy R and D promote renewable energy consumption. • Fossil fuel R and D promotes fossil fuel consumption in countries with oil reserves. • Oil consumption reduces significantly with higher oil prices

  20. Combined effect of carnosol, rosmarinic acid and thymol on the oxidative stability of soybean oil using a simplex centroid mixture design.

    Science.gov (United States)

    Saoudi, Salma; Chammem, Nadia; Sifaoui, Ines; Jiménez, Ignacio A; Lorenzo-Morales, Jacob; Piñero, José E; Bouassida-Beji, Maha; Hamdi, Moktar; L Bazzocchi, Isabel

    2017-08-01

    Oxidation taking place during the use of oil leads to the deterioration of both nutritional and sensorial qualities. Natural antioxidants from herbs and plants are rich in phenolic compounds and could therefore be more efficient than synthetic ones in preventing lipid oxidation reactions. This study was aimed at the valorization of Tunisian aromatic plants and their active compounds as new sources of natural antioxidant preventing oil oxidation. Carnosol, rosmarinic acid and thymol were isolated from Rosmarinus officinalis and Thymus capitatus by column chromatography and were analyzed by nuclear magnetic resonance. Their antioxidant activities were measured by DPPH, ABTS and FRAP assays. These active compounds were added to soybean oil in different proportions using a simplex-centroid mixture design. Antioxidant activity and oxidative stability of oils were determined before and after 20 days of accelerated oxidation at 60 °C. Results showed that bioactive compounds are effective in maintaining oxidative stability of soybean oil. However, the binary interaction of rosmarinic acid and thymol caused a reduction in antioxidant activity and oxidative stability of soybean oil. Optimum conditions for maximum antioxidant activity and oxidative stability were found to be an equal ternary mixture of carnosol, rosmarinic acid and thymol. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  1. Prediction of Dangerous Time in Case Hydrocarbon Refrigerant Leaks into Household Refrigerator Cabinet

    Science.gov (United States)

    Meguro, Takatoshi; Kaji, Nobufuji; Miyake, Kunihiro

    Hydrocarbon refrigerators are now on sale in European countries. However, hydrocarbons are flammable. A common claim is that concentration of hydrocarbon in the refrigerator could exceed the lower explosive limit by a sudden leak and then a spark ignites a flame causing overpressure. There is the need of the studies on potential risks originated from the use of flammable refrigerants. Thus, the flow rate of the fresh air into the refrigerator cabinet has been defined experimentally, and the spatial average concentration in the refrigerator cabinet has been analyzed theoretically to predict the dangerous time in excess of the lower explosive limit.

  2. Chemical composition, antioxidant and antimicrobial activity of the essential oil from the leaves of Macleaya cordata (Willd) R. Br.

    Science.gov (United States)

    Li, Chun-Mei; Yang, Xiao-Yong; Zhong, Yi-Rong; Yu, Jian-Ping

    2016-01-01

    The essential oil from the leaves of Macleaya cordata R.Br. obtained by hydrodistillation was analysed by gas chromatography/mass spectrometry. Sixty-eight compounds consisting of up to 92.53% of the essential oil were identified. Antioxidant activities of the essential oil were evaluated by using DPPH radical scavenging and β-carotene-linoleic acid assays. The essential oil showed moderate antioxidant activity. In addition, the essential oil exhibited potential antimicrobial activity against all tested microorganisms, with diameters of inhibition zones ranging from 8.7 ± 0.5 to 17.2 ± 1.2 mm and minimum inhibitory concentration values from 125 to 500 μg/mL. We selected the most sensitive bacterium Staphylococcus aureus as model to observe of the action of essential oils of M. cordata on the membrane structure by scanning electron microscopy. The treated cell membranes were damaged severely. The results presented here indicate that the essential oil of M. cordata may be potential sources of antioxidant and antimicrobial agents in the future.

  3. Method of separation of gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Berlin, M.A.; Potapov, V.F.; Potapova, M.S.

    1980-04-05

    Gas mixtures are separated in a rectification tower by repeated counterflow contact of the heated gas flow and cool condensate as the pressure drops in each stage of separation (StR) and when condensate is added from StR with lower pressure to the StR with higher pressure. In order to reduce energy consumption noncondensing gas in amounts of 5-15 percent by weight of the amount of incoming gases are added. Hydrocarbon or carbon dioxide gas can be used as the latter. Example. To separate natural gas of the Shatlyk deposit of composition, percent by mo1: C1 -- 94.960; C2 -- 4.260; C3 -- 0.200; C4 -- 0.08; C4+B -- 0.51. It is enriched with carbon dioxide gas in an amount of 10 percent by weight. Upon rectification of the enriched hydrocarbon mixture separation is achieved at lower pressures of the gas mixture and less cold. This leads to reduction of energy consumption by 10-12 percent.

  4. Cyst Ablation Using a Mixture of N-Butyl Cyanoacrylate and Iodized Oil in Patients with Autosomal Dominant Polycystic Kidney Disease: the Long-Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Seung Hyup; Cho, Jeong Yeon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    We wanted to assess the long-term results of cyst ablation with using N-butyl cyanoacrylate (NBCA) and iodized oil in patients with autosomal dominant polycystic kidney disease (ADPKD) and symptomatic cysts. Cyst ablation using a mixture of NBCA and iodized oil was performed in 99 cysts from 21 patients who had such symptoms as abdominal distension and pain. The collapse or reaccumulation of the ablated cysts after the procedure was assessed during the follow-up period of 36 to 90 months. The treatment effects, including symptom relief, and the clinical data such as the blood pressure and serum creatinine levels were also assessed, together with the complications. The procedure was technically successful in all 99 cysts from the 21 patients. Any procedure-related significant complications were not detected. Seventy-seven of 99 cysts (78%) were successfully collapsed on the follow-up CT. Twenty-two cysts showed reaccumulation during long-term follow-up period. The clinical symptoms were relieved in 17 of the 21 patients (76%). Four of 12 patients (33%) with hypertension and two of six patients (33%) with azotemia were improved. End stage renal disease (ESRD) occurred in six of the 21 patients (28%) during the follow-up period. The mean age of ESRD in our patients was 57 years. The mean time interval for the development of ESRD was 19 months. Ablation using a mixture of NBCA and iodized oil may be an effective, safe method for obtaining symptom relief in patients with ADPKD.

  5. Optimization of Surfactant Mixtures and Their Interfacial Behavior for Advanced Oil Recovery, Annual Report, September 30, 1999-September 30, 2000

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaran, Prof. P.

    2001-04-04

    The goal of this report is to develop improved extraction processes to mobilize and produce the oil left untapped using conventional techniques. Current chemical schemes for recovering the residual oil have been in general less than satisfactory. High cost of the processes as well as significant loss of chemicals by adsorption on reservoir materials and precipitation has limited the utility of chemical-flooding operations. There is a need to develop cost-effective, improved reagent schemes to increase recovery from domestic oil reservoirs. The goal of the report was to develop and evaluate novel mixtures of surfactants for improved oil recovery.

  6. Predicting skin permeability from complex chemical mixtures

    International Nuclear Information System (INIS)

    Riviere, Jim E.; Brooks, James D.

    2005-01-01

    Occupational and environmental exposure to topical chemicals is usually in the form of complex chemical mixtures, yet risk assessment is based on experimentally derived data from individual chemical exposures from a single, usually aqueous vehicle, or from computed physiochemical properties. We present an approach using hybrid quantitative structure permeation relationships (QSPeR) models where absorption through porcine skin flow-through diffusion cells is well predicted using a QSPeR model describing the individual penetrants, coupled with a mixture factor (MF) that accounts for physicochemical properties of the vehicle/mixture components. The baseline equation is log k p = c + mMF + aΣα 2 H + bΣβ 2 H + sπ 2 H + rR 2 + vV x where Σα 2 H is the hydrogen-bond donor acidity, Σβ 2 H is the hydrogen-bond acceptor basicity, π 2 H is the dipolarity/polarizability, R 2 represents the excess molar refractivity, and V x is the McGowan volume of the penetrants of interest; c, m, a, b, s, r, and v are strength coefficients coupling these descriptors to skin permeability (k p ) of 12 penetrants (atrazine, chlorpyrifos, ethylparathion, fenthion, methylparathion, nonylphenol, ρ-nitrophenol, pentachlorophenol, phenol, propazine, simazine, and triazine) in 24 mixtures. Mixtures consisted of full factorial combinations of vehicles (water, ethanol, propylene glycol) and additives (sodium lauryl sulfate, methyl nicotinate). An additional set of 4 penetrants (DEET, SDS, permethrin, ricinoleic acid) in different mixtures were included to assess applicability of this approach. This resulted in a dataset of 16 compounds administered in 344 treatment combinations. Across all exposures with no MF, R 2 for absorption was 0.62. With the MF, correlations increased up to 0.78. Parameters correlated to the MF include refractive index, polarizability and log (1/Henry's Law Constant) of the mixture components. These factors should not be considered final as the focus of these studies

  7. Effect of CuO nanolubricant on compressor characteristics and performance of LPG based refrigeration cycle: experimental investigation

    Science.gov (United States)

    Kumar, Ravinder; Singh, Jagdev; Kundal, Pankaj

    2018-05-01

    Refrigeration, Ventilation and Air Conditioning system is the largest reason behind the increasing demand of energy consumption in the world and saving that energy through some innovative methods becomes a large issue for the researchers. Compressor is a primary component of the refrigeration cycle. The application of nanoparticles in refrigeration cycle overcomes the energy consumption issue by improving the compressor suction and discharge characteristics. In this paper, an experimental study is carried out to investigate the effect of copper oxide (CuO) nanoparticles on different parameters of the refrigeration cycle. CuO particles are appended with the system refrigerant through lubricating oil of the compressor. Further, the viscosity measurements and friction coefficient analysis of compressor lubricant for different fractions of nanoparticles has been investigated. The results showed that both the suction and discharge characteristics of the compressor were enhanced with the utilization of nanolubricant in LPG based refrigeration cycle. Nanoparticles additive in lubricant increases the viscosity which lead to a significant decrease in friction coefficient. The COP of the cycle was improved by 46%, as the energy consumption of the compressor was decreased by 7%.

  8. Effect of CuO nanolubricant on compressor characteristics and performance of LPG based refrigeration cycle: experimental investigation

    Science.gov (United States)

    Kumar, Ravinder; Singh, Jagdev; Kundal, Pankaj

    2017-11-01

    Refrigeration, Ventilation and Air Conditioning system is the largest reason behind the increasing demand of energy consumption in the world and saving that energy through some innovative methods becomes a large issue for the researchers. Compressor is a primary component of the refrigeration cycle. The application of nanoparticles in refrigeration cycle overcomes the energy consumption issue by improving the compressor suction and discharge characteristics. In this paper, an experimental study is carried out to investigate the effect of copper oxide (CuO) nanoparticles on different parameters of the refrigeration cycle. CuO particles are appended with the system refrigerant through lubricating oil of the compressor. Further, the viscosity measurements and friction coefficient analysis of compressor lubricant for different fractions of nanoparticles has been investigated. The results showed that both the suction and discharge characteristics of the compressor were enhanced with the utilization of nanolubricant in LPG based refrigeration cycle. Nanoparticles additive in lubricant increases the viscosity which lead to a significant decrease in friction coefficient. The COP of the cycle was improved by 46%, as the energy consumption of the compressor was decreased by 7%.

  9. Bubble nucleation of R134A refrigerant in a pressurized flow boiling system

    Energy Technology Data Exchange (ETDEWEB)

    Murshed, S.M. Sohel; Vereen, Keon; Kumar, Ranganathan [University of Central Florida, Orlando, FL (United States). Dept. of Mechanical, Materials and Aerospace Engineering], e-mail: rnkumar@mail.ucf.edu

    2009-07-01

    The effect of heat flux and pressure on bubble nucleation of R134a refrigerant in a flow boiling system is experimentally studied. An experimental facility was built and an innovative concept of thermochromic liquid crystal (TLC) technique was introduced for the high resolution and accurate measurement of the overall heater surface temperature. The visualization and image recording process is performed by employing two synchronized high resolution and high speed cameras which simultaneously capture colored TLC images as well as bubble nucleation activities at high frame rates. Experiments were conducted at different high pressures ranging from 690 to 830 kPa and at different heat flux conditions in order to identify their influence on flow boiling performance specially bubbling event. Present results demonstrate that both the heat flux and pressure influence the bubble generation rate and size. For example, bubble generation frequency and size are found to increase with heat flux. An increase in pressure of 137 kPa (from 690 to 827 kPa) increased the bubble frequency and size about 32 Hz and 20 {mu}m, respectively. (author)

  10. Bubble nucleation of R134A refrigerant in a pressurized flow boiling system

    International Nuclear Information System (INIS)

    Murshed, S.M. Sohel; Vereen, Keon; Kumar, Ranganathan

    2009-01-01

    The effect of heat flux and pressure on bubble nucleation of R134a refrigerant in a flow boiling system is experimentally studied. An experimental facility was built and an innovative concept of thermochromic liquid crystal (TLC) technique was introduced for the high resolution and accurate measurement of the overall heater surface temperature. The visualization and image recording process is performed by employing two synchronized high resolution and high speed cameras which simultaneously capture colored TLC images as well as bubble nucleation activities at high frame rates. Experiments were conducted at different high pressures ranging from 690 to 830 kPa and at different heat flux conditions in order to identify their influence on flow boiling performance specially bubbling event. Present results demonstrate that both the heat flux and pressure influence the bubble generation rate and size. For example, bubble generation frequency and size are found to increase with heat flux. An increase in pressure of 137 kPa (from 690 to 827 kPa) increased the bubble frequency and size about 32 Hz and 20 μm, respectively. (author)

  11. Sustainable hydrogen production from bio-oil model compounds (meta-xylene) and mixtures (1-butanol, meta-xylene and furfural).

    Science.gov (United States)

    Bizkarra, K; Barrio, V L; Arias, P L; Cambra, J F

    2016-09-01

    In the present work m-xylene and an equimolecular mixture of m-xylene, 1-butanol and furfural, all of them bio-oil model compounds, were studied in steam reforming (SR) conditions. Three different nickel catalysts, which showed to be active in 1-butanol SR (Ni/Al2O3, Ni/CeO2-Al2O3 and Ni/La2O3-Al2O3), were tested and compared with thermodynamic equilibrium values. Tests were carried out at temperatures from 800 to 600°C at atmospheric pressure with a steam to carbon ratio (S/C) of 5.0. Despite the different bio-oils fed, the amount of moles going through the catalytic bed was kept constant in order to obtain comparable results. After their use, catalysts were characterized by different techniques and those values were correlated with the activity results. All catalysts were deactivated during the SR of the mixture, mainly by coking. The highest hydrogen yields were obtained with Ni/Al2O3 and Ni/CeO2-Al2O3 catalysts in the SR of m-xylene and SR of the mixture, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Developments in magnetocaloric refrigeration

    International Nuclear Information System (INIS)

    Brueck, Ekkes

    2005-01-01

    Modern society relies on readily available refrigeration. Magnetic refrigeration has three prominent advantages compared with compressor-based refrigeration. First, there are no harmful gases involved; second, it may be built more compactly as the working material is a solid; and third, magnetic refrigerators generate much less noise. Recently a new class of magnetic refrigerant-materials for room-temperature applications was discovered. These new materials have important advantages over existing magnetic coolants: they exhibit a large magnetocaloric effect (MCE) in conjunction with a magnetic phase-transition of first order. This MCE is larger than that of Gd metal, which is used in the demonstration refrigerators built to explore the potential of this evolving technology. In the present review we compare the different materials considering both scientific aspects and industrial applicability. Because fundamental aspects of MCE are not so widely discussed, we also give some theoretical considerations. (topical review)

  13. Optimization of Microencapsulation of Fish Oil with Gum Arabic/Casein/Beta-Cyclodextrin Mixtures by Spray Drying.

    Science.gov (United States)

    Li, Junjie; Xiong, Shanbai; Wang, Fang; Regenstein, Joe M; Liu, Ru

    2015-07-01

    Fish oil was encapsulated with gum arabic/casein/beta-cyclodextrin mixtures using spray drying. The processing parameters (solids concentration of the barrier solutions, ratio of oil to barrier materials, emulsifying temperature, and air inlet temperature) were optimized based on emulsion viscosity, emulsion stability, encapsulation efficiency, and yield. A suitable viscosity and high emulsion stability could increase encapsulation efficiency and yield. Encapsulation efficiency and yield were significantly affected by all the 4 parameters. Based on the results of orthogonal experiments, encapsulation efficiency and yield reached a maximum of 79.6% and 55.6%, respectively, at the optimal condition: solids concentration of 35%, ratios of oil to barrier materials of 3:7, emulsifying temperature of 55 °C, and air inlet temperature of 220 °C. Scanning electron microscopy analysis showed that fish oil microcapsules were nearly spherical with a smooth surface with droplet size ranging from 1 to 10 μm. © 2015 Institute of Food Technologists®

  14. 49 CFR 173.313 - UN Portable Tank Table for Liquefied Compressed Gases.

    Science.gov (United States)

    2010-10-01

    ... Refrigerant gas R 21 7.0 Allowed Normal 1.23 7.0 7.0 7.0 1030 1,1-Difluoroethane or Refrigerant gas R 152a 16....1 Allowed Normal 1.07 20.8 18.6 16.6 2517 1-Chloro-1,1-difluoroethane or Refrigerant gas R 142b 8.9 Allowed Normal 0.99 7.8 7.0 7.0 2602 Dichlorodifluoromethane and difluoroethane azeotropic mixture with...

  15. Effects of mixtures of persistent organic pollutants (POPs) derived from cod liver oil on H295R steroidogenesis

    NARCIS (Netherlands)

    Montano, M.; Zimmer, K.E.; Dahl, E.; Berge, V.; Olsaker, I.; Skaare, J.U.; Murk, A.J.; Ropstad, E.; Verhaegen, S.

    2011-01-01

    Crude cod liver oil and liver oil supplements are consumed as a source of vitamin A, D and polyunsaturated fatty acids; during winter and early pregnancy. Crude cod liver oil however constitutes a considerable source of persistent organic pollutants (POPs). This paper aimed at characterizing and

  16. Modelling of fluid flow through short tube orifices under metastable conditions: A new numerical validation approach for evaluating the mass flow rate with refrigerant mixtures (HFC-407C and HFC-410A)

    International Nuclear Information System (INIS)

    García-Valladares, O.; Santoyo, E.

    2014-01-01

    In a previous work, one-dimensional numerical modelling of fluid-flow inside short tube orifices was performed, and successfully validated against a wide range of mass flow rate measurements reported for the refrigerant HFC-134a. Governing equations of continuity, momentum, energy and entropy were solved for describing the fluid flow under a wide variety of thermodynamic transitions (e.g., subcooled liquid region, metastable liquid region, metastable two-phase region and equilibrium two-phase region), including sudden contraction and enlargement. In this new study, a comprehensive comparison analysis between numerical simulation data and experimental measurements obtained for HFC-407C and HFC-410A refrigerants (N o  = 241) to extend the applicability of the same mathematical model was carried out. Using a widespread statistical analysis, based on weighted linear regressions with an outlier detection/rejection module at 95% of confidence level, the prediction performance of the mathematical model was again assessed. Linear regressions between predicted mass flow rate data and experimental measurements were computed, and used them as a statistical comparison criterion. A statistical comparison between predicted simulation results and mass flow rate experimental data are reported. Average deviation errors of ±11.1% (for the refrigerant HFC-407C) and ±7.3% (for refrigerant HFC-410A) were found between numerical model and experimental data. These results demonstrate a new and robust application of the model to predict reliably the mass flow rate through short tube orifices under metastable conditions, which enable this tool to be reliably used for the design of short tube orifices. - Highlights: •A modelling for evaluating short tube orifice was developed for refrigerant mixtures. •The numerical model applied considered metastable regions and choke flow. •The model was validated against experimental data for HFC-407C and HFC-410A. •Statistical analysis based

  17. Deposition of heavy oil fractions: development of a computational tool to predict oil mixtures compatibility; Deposicao de fracoes pesadas do petroleo: desenvolvimento de uma ferramenta computacional para a previsao da compatibilidade de misturas de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Prucole, Elisia S.; Henriques, Fernanda P.; Silva, Leandro M.; Touma, Silvia L. [PETROBRAS S.A., Rio de de Janeiro, RJ (Brazil)

    2008-07-01

    The remarkable increase in production and processing of national heavy oils is a scenario in which the deposition problem of heavy oil fractions is important, leading to huge losses, not only in economical terms but also in regard to environmental aspects, and can occur in practically all areas of the oil industry. Thus, the knowledge about technology concerning this subject is essential. In terms of heavy fractions, the asphaltenes are the heaviest components of oil and have propensity to aggregate, flocculate, precipitate and be adsorbed on surfaces. The difficulties for modeling the behavior of asphaltenes phases occur because of the high uncertainties which take in the current knowledge about the asphaltenes, their structures, flocculation and precipitation mechanisms and the phenomenon reversibility. The main goal of this work is to propose a predictive methodology for oils compatibility. A fuzzy classifier was implemented in order to predict the compatibility of oil mixtures, assessing whether the mixture condition is stable or not. The results were satisfactory, indicating a good predictive power of the proposed computational tool. (author)

  18. The R Package bgmm : Mixture Modeling with Uncertain Knowledge

    Directory of Open Access Journals (Sweden)

    Przemys law Biecek

    2012-04-01

    Full Text Available Classical supervised learning enjoys the luxury of accessing the true known labels for the observations in a modeled dataset. Real life, however, poses an abundance of problems, where the labels are only partially defined, i.e., are uncertain and given only for a subsetof observations. Such partial labels can occur regardless of the knowledge source. For example, an experimental assessment of labels may have limited capacity and is prone to measurement errors. Also expert knowledge is often restricted to a specialized area and is thus unlikely to provide trustworthy labels for all observations in the dataset. Partially supervised mixture modeling is able to process such sparse and imprecise input. Here, we present an R package calledbgmm, which implements two partially supervised mixture modeling methods: soft-label and belief-based modeling. For completeness, we equipped the package also with the functionality of unsupervised, semi- and fully supervised mixture modeling. On real data we present the usage of bgmm for basic model-fitting in all modeling variants. The package can be applied also to selection of the best-fitting from a set of models with different component numbers or constraints on their structures. This functionality is presented on an artificial dataset, which can be simulated in bgmm from a distribution defined by a given model.

  19. Effect of Vegetable Oil Fortified Feeds on the Content of Fatty Acids in Breast and Thigh Muscles in Broiler Chickens

    Directory of Open Access Journals (Sweden)

    Tereza Krejčí-Treu

    2010-01-01

    Full Text Available The main objective of this work was to compare the effect of six vegetable oils added to feeding mixtures that were administered to broiler chickens on the content of major fatty acids in chicken meat. The experiment started with 90 one-day-old Ross 308 meat hybrid male chickens that were divided into six groups. Chickens were fed complete feeding mixtures for the prefattening (BR1, fattening (BR2, and post-fattening (BR3 of broiler chickens. The BR1 feeding mixture was administered to chickens aged 1-10 days, the BR2 feeding mixture was given from Day 11 to Day 30, and the BR3 feeding mixture was then administered until Day 42. The BR1 feeding mixture that was administered to all six groups during the first ten days of the experiment was supplemented with soybean oil. BR2 and BR3 feeding mixtures used to feed chickens aged 11-42 days were fortified with soybean oil (SO Group, rapeseed oil (RO Group, sunflower oil (SFO Group, flaxseed oil (FO Group, olive oil (OO Group, and evening primrose oil (EPO Group. The vegetable oils used differed by the composition of fatty acids, particularly by the content of oleic acid, linoleic acid, α-linolenic acid. The use of the above-described experimental diets in young broilers from Day 11 to 42 had a significant effect on the content of fatty acids in the fat from breast and thigh muscles. The content of α-linolenic acid in breast and thigh muscles of broilers that received the feed containing flaxseed oil (21.16 g/100 g of oil and 17.13 g/100 g of oil, respectively significantly increased (p ⪬ 0.01. The highest content of linoleic acid (p ⪬ 0.01 in breast and thigh muscles was found in chickens that were fed the feed containing primrose oil (59.13 g/100 g and 51.71 g/100 g. A significant increase (p ⪬ 0.01 in the level of oleic acid was detected in both breast and thigh muscles of broilers that received olive oil fortified feed (52.44 g/100 g and 43.70 g/100 g of oil. No significant variation was

  20. Refrigerant charge, pressure drop, and condensation heat transfer in flattened tubes

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, M J; Newell, T A; Chato, J C [University of Illinois, Urbana, IL (United States). Dept. of Mechanical and Industrial Engineering; Infante Ferreira, C A [Delft University of Technology (Netherlands). Laboratory for Refrigeration and Indoor Climate Control

    2003-06-01

    Horizontal smooth and microfinned copper tubes with an approximate diameter of 9 mm were successively flattened in order to determine changes in flow field characteristics as a round tube is altered into a flattened tube profile. Refrigerants R134a and R410A were investigated over a mass flux range from 75 to 400 kg m{sup -2} s{sup -}2{sup 1} and a quality range from approximately 10-80%. For a given refrigerant mass flow rate, the results show that a significant reduction in refrigerant charge is possible. Pressure drop results show increases of pressure drop at a given mass flux and quality as a tube profile is flattened. Heat transfer results indicate enhancement of the condensation heat transfer coefficient as a tube is flattened. Flattened tubes with an 18{sup o} helix angle displayed the highest heat transfer coefficients. Smooth tubes and axial microfin tubes displayed similar levels of heat transfer enhancement. Heat transfer enhancement is dependent on the mass flux, quality and tube profile. (author)

  1. Fermilab tevatron five refrigerator system tests

    International Nuclear Information System (INIS)

    Rode, C.; Ferry, R.; Leiniger, M.; Makara, J.; Misek, J.; Mizicko, D.; Richied, D.; Theilacker, J.

    1982-01-01

    The Fermilab Tevatron refrigeration system is described with the layout illustrated. The compressor control loops, the refrigerator control loops, and magnet control loops (two per refrigerator) are described and each illustrated. The mobile purifier is described. A five refrigerator test is presented, using two compressor buildings, satellite refrigerator concept test and the test current to the writing. The configuration of the five refrigerator test is diagramed

  2. Design of an ejector cycle refrigeration system

    International Nuclear Information System (INIS)

    Grazzini, G.; Milazzo, A.; Paganini, D.

    2012-01-01

    Highlights: ► A design procedure is presented for an ejection refrigeration system. ► Properties of applicable operating fluids are presented and R245fa is selected. ► Real gas properties are used. ► The diffuser is designed with a profile that controls momentum change. ► Fluid friction is accounted for along all main components. - Abstract: A design procedure, based on a one-dimensional simulation, is presented for an ejection refrigeration system. Heat exchangers are included in the calculation, accounting for temperature differences between the fluids and for pressure losses. The ideal gas assumption, which is quite common in the literature concerning ejector systems, is avoided. Furthermore, the supersonic diffuser is designed with a continuous profile, without cylindrical piece, controlling the variation of momentum along the flow path and accounting for friction. At design conditions, this should reduce the irreversibility due to the normal shock. A comparison between different operating fluids is presented and R245fa is selected. The results of the design procedure and the expected performance, in terms of first and second law efficiency, are presented.

  3. Effect of refrigeration time on the lipid oxidation and fatty acid profiles of catfish (Arius maculatus) commercialized in Cameroon

    International Nuclear Information System (INIS)

    Tenyang, N.; Womeni, H.M.; Tiencheu, B.; Villeneuve, P.; Linder, M.

    2017-01-01

    The effects of refrigeration at 4 °C during 9 days on the quality and stability of catfish oil were evaluated using a change in fatty acid composition by gas chromatography (GC), commonly used analytical indexes (acid and peroxide values), and analysis by Fourier transform infrared (FTIR) spectroscopy. The results revealed that lipid deterioration, hydrolysis and oxidation occurred throughout the cold storage (4 °C). Refrigeration induced the lipolysis of triglycerides by lipases and phospholipases. It also affected the fatty acids composition of the catfish. The progressive loss of unsaturation was monitored by the decrease in the absorbance band at 3012 cm−1on FTIR spectra and the lowest value was observed in the catfish muscle at 9 days of refrigeration. Eicosapentaenoic C20:5ω3 (EPA) and docosahexaenoic C22:6ω3 (DHA) acids were the polyunsaturated fatty acids most affected during refrigeration. Refrigeration for less than 5 days was found to be the best conditions for the preservation of the catfish. [es

  4. Analysis of ORC (Organic Rankine Cycle) systems with pure hydrocarbons and mixtures of hydrocarbon and retardant for engine waste heat recovery

    International Nuclear Information System (INIS)

    Song, Jian; Gu, Chun-wei

    2015-01-01

    The Organic Rankine Cycle (ORC) has been demonstrated to be a promising technology for the recovery of engine waste heat. Systems with hydrocarbons as the working fluids exhibit good thermal performance. However, the flammability of hydrocarbons limits their practical applications because of safety concerns. This paper examines the potential of using mixtures of a hydrocarbon and a retardant in an ORC system for engine waste heat recovery. Refrigerants R141b and R11 are selected as the retardants and blended with the hydrocarbons to form zeotropic mixtures. The flammability is suppressed, and in addition, zeotropic mixtures provide better temperature matches with the heat source and sink, which reduces the exergy loss within the heat exchange processes, thereby increasing the cycle efficiency. Energetic and exergetic analysis of ORC systems with pure hydrocarbons and with mixtures of a hydrocarbon and a retardant are conducted and compared. The net power output and the second law efficiency are chosen as the evaluation criteria to select the suitable working fluid compositions and to define the optimal set of thermodynamic parameters. The simulation results reveal that the ORC system with cyclohexane/R141b (0.5/0.5) is optimal for this engine waste heat recovery case, thereby increasing the net power output of the system by 13.3% compared to pure cyclohexane. - Highlights: • ORC with zeotropic mixtures for engine waste heat recovery is discussed. • Energetic and exergetic analysis of ORC system are conducted. • Optimal mixture working fluid composition is identified. • Greater utilization of jacket water and lower irreversible loss are important.

  5. Analysis of DC control in double-inlet GM type pulse tube refrigerators for detectors

    Science.gov (United States)

    Du, B. Y.

    2016-10-01

    Pulse tube refrigerators have demonstrated many advantages with respect to temperature stability, vibration, reliability and lifetime among cryo-coolers for detectors. Double-inlet type pulse tube refrigerators are popular in GM type pulse tube refrigerators. The single double-inlet valve may introduce DC flow in refrigerator, which deteriorates the performance of pulse tube refrigerator. One new type of DC control mode is introduced in this paper. Two parallel-placed needle valves with opposite direction named double-valve configuration, instead of single double-inlet valve, are used in our experiment to reduce the DC flow. With two double-inlet operating, the lowest cold end temperature of 18.1K and a coolant of 1.2W@20K have been obtained. It has proved that this method is useful for controlling DC flow of the pulse tube refrigerators, which is very important to understand the characters of pulse tube refrigerators for detectors.

  6. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1994-05-27

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  7. Heat transfer degradation during condensation of non-azeotropic mixtures

    Science.gov (United States)

    Azzolin, M.; Berto, A.; Bortolin, S.; Del, D., Col

    2017-11-01

    International organizations call for a reduction of the HFCs production and utilizations in the next years. Binary or ternary blends of hydroflourocarbons (HFCs) and hydrofluoroolefins (HFOs) are emerging as possible substitutes for high Global Warming Potential (GWP) fluids currently employed in some refrigeration and air-conditioning applications. In some cases, these mixtures are non-azeotropic and thus, during phase-change at constant pressure, they present a temperature glide that, for some blends, can be higher than 10 K. Such temperature variation during phase change could lead to a better matching between the refrigerant and the water temperature profiles in a condenser, thus reducing the exergy losses associated with the heat transfer process. Nevertheless, the additional mass transfer resistance which occurs during the phase change of zeotropic mixtures leads to a heat transfer degradation. Therefore, the design of a condenser working with a zeotropic mixture poses the problem of how to extend the correlations developed for pure fluids to the case of condensation of mixtures. Experimental data taken are very helpful in the assessment of design procedures. In the present paper, heat transfer coefficients have been measured during condensation of zeotropic mixtures of HFC and HFO fluids. Tests have been carried out in the test rig available at the Two Phase Heat Transfer Lab of University of Padova. During the condensation tests, the heat is subtracted from the mixture by using cold water and the heat transfer coefficient is obtained from the measurement of the heat flux on the water side, the direct measurements of the wall temperature and saturation temperature. Tests have been performed at 40°C mean saturation temperature. The present experimental database is used to assess predictive correlations for condensation of mixtures, providing valuable information on the applicability of available models.

  8. Excess molar volumes and viscosities of binary mixtures of 1,2

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 113; Issue 3. Excess molar volumes and viscosities of binary mixtures of 1,2-diethoxyethane with chloroalkanes ... The Bloomfield and Dewan model has been used to calculate viscosity ...

  9. Experiments on condensation heat transfer characteristics inside a microfin tube with R410A

    Energy Technology Data Exchange (ETDEWEB)

    Han, D H; Cho, Y J [Korea University Graduate School, Seoul (Korea); Lee, K J; Park, S S [Korea University, Seoul (Korea)

    2000-11-01

    Due to the ozone depletion and global warming potentials, some refrigerants (CFCs and HCFCs) have been rapidly substituted. R410A is considered as the alternative refrigerant of R22 for the air-conditioners used at home and in industry. Experiments on the condensation heat transfer characteristics inside a smooth or a micro-fin tube with R410A are performed in this study. The test tubes 7/9.52 mm in outer diameters and 3 m in length are used. Varying the mass flux of the refrigerant and the condensation temperatures, the average heat transfer coefficients and pressure drop are investigated. It is shown that the heat transfer is enhanced and the amount of pressure drops are larger in the microfin tube than the smooth tube. From the heat transfer enhancement coefficient and the pressure penalty factor, it is found that the high heat transfer enhancement coefficients are obtained in the range of small mass flux while the penalty factors are almost equal. (author). 13 refs., 12 figs., 1 tab.

  10. Experimental analysis of refrigerants flow boiling inside small sized microfin tubes

    Science.gov (United States)

    Diani, Andrea; Rossetto, Luisa

    2017-07-01

    The refrigerant charge reduction is one of the most challenging issues that the scientific community has to cope to reduce the anthropic global warming. Recently, mini microfin tubes have been matter of research, since they can reach better thermal performance in small domains, leading to a further refrigerant charge reduction. This paper presents experimental results about R134a flow boiling inside a microfin tube having an internal diameter at the fin tip of 2.4 mm. The mass flux was varied between 375 and 940 kg m-2 s-1, heat flux from 10 to 50 kW m-2, vapor quality from 0.10 to 0.99. The saturation temperature at the inlet of the test section was kept constant and equal to 30 °C. R134a thermal and fluid dynamic performances are presented and compared against those obtained with R1234ze(E) and R1234yf and against values obtained during R134a flow boiling inside a 3.4 mm ID microfin tube.

  11. Molecular interactions of CPC, CPB, CTAB, and EPC biosurfactants in aqueous olive oil mixtures analyzed with physicochemical data and SEM micrographs

    Directory of Open Access Journals (Sweden)

    Man Singh

    2014-12-01

    Full Text Available Structural studies of olive oil–water–biosurfactants mixtures are most attracting for several academic as well as industrial significances. Thus, densities (ρ, viscosities (η, and surface tensions (γ of cetylpyridinium chloride (CPC and bromide (CPB, cetyltrimethylammonium bromide (CTAB and egg-phosphatidylcholine (EPC biosurfactants (BS 2–10 mm kg−1 in olive oil + water mixture in 2 mm kg−1 interval at 310.15 K are reported. The densities were for apparent molal volume (Vϕ/10−6 m3 mol−1, η and γ determinations. The viscosities were fitted in extended Jones–Doles equation for intrinsic viscosity (B, kg mol−1 and slope (D, kg mol−12 derivation. The γ and Vϕ data were regressed for their limiting γ0 andVϕ0 data and the SEMs were illustrated surface morphology. The EPC caused maximum oil–water dissolution as compared to other surfactants. Intramolecular multiple force theory [IMMFT] is proposed to explain molecular interactions of olive oil–water–EPC mixtures with a possible correlation of surface and bulk reorientations with microstructures depicted with SEM. Frictional and cohesive forces as Friccohesity have been noted as driving forces to assert for validity of the IMMFT model and its link with SEM.

  12. A predictive method for crude oil volatile organic compounds emission from soil: evaporation and diffusion behavior investigation of binary gas mixtures.

    Science.gov (United States)

    Wang, Haijing; Fischer, Thomas; Wieprecht, Wolfgang; Möller, Detlev

    2015-05-01

    Due to their mobility and toxicity, crude oil volatile organic compounds (VOCs) are representative components for oil pipeline contaminated sites detection. Therefore, contaminated location risk assessment, with airborne light detection and ranging (LIDAR) survey, in particular, requires ground-based determinative methods for oil VOCs, the interaction between oil VOCs and soil, and information on how they diffuse from underground into atmosphere. First, we developed a method for determination of crude oil VOC binary mixtures (take n-pentane and n-hexane as examples), taking synergistic effects of VOC mixtures on polydimethylsiloxane (PDMS) solid-phase microextraction (SPME) fibers into consideration. Using this method, we further aim to extract VOCs from small volumes, for example, from soil pores, using a custom-made sampling device for nondestructive SPME fiber intrusion, and to study VOC transport through heterogeneous porous media. Second, specific surface Brunauer-Emmett-Teller (BET) analysis was conducted and used for estimation of VOC isotherm parameters in soil. Finally, two models were fitted for VOC emission prediction, and the results were compared to the experimental emission results. It was found that free diffusion mode worked well, and an empirical correction factor seems to be needed for the other model to adapt to our condition for single and binary systems.

  13. Magnon-driven quantum dot refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuan; Huang, Chuankun; Liao, Tianjun; Chen, Jincan, E-mail: jcchen@xmu.edu.cn

    2015-12-18

    Highlights: • A three-terminal quantum dot refrigerator is proposed. • The effects of magnetic field, applied voltage, and polarization are considered. • The region that the system can work as a refrigerator is determined. • Two different magnon-driven quantum dot refrigerators are compared. - Abstract: A new model of refrigerator consisting of a spin-splitting quantum dot coupled with two ferromagnetic reservoirs and a ferromagnetic insulator is proposed. The rate equation is used to calculate the occupation probabilities of the quantum dot. The expressions of the electron and magnon currents are obtained. The region that the system can work in as a refrigerator is determined. The cooling power and coefficient of performance (COP) of the refrigerator are derived. The influences of the magnetic field, applied voltage, and polarization of two leads on the performance are discussed. The performances of two different magnon-driven quantum dot refrigerators are compared.

  14. Adaptation of systems to fluid changes; Adaptation des systemes aux changements de fluides

    Energy Technology Data Exchange (ETDEWEB)

    Clodic, D. [Ecole Nationale Superieure des Mines, 75 - Paris (France)

    1996-12-31

    Regulation constraints and the stoppage of CFCs production and HCFCs production in the future lead to rapid evolutions in the conceiving of refrigerating installations which are linked with refrigerant changes. The refrigerant/installation pair has become the aim of detailed analyses in order to understand the relation between the thermodynamical properties of fluids and the energy efficiency of refrigerating installations. The efficiency depends entirely on the global design of the installation while the choice of the fluid is only one element that contributes to this efficiency. This paper analyzes successively: the consequences of pure refrigerant substitution on volume and centrifugal compressors, and the constraints linked with the use of mixtures close to azeotropic compounds (R408A and R404A) and mixtures with temperature shift like R407C. In this last case, the replacement is deeply different in the case of water heat exchangers and in the case of air-circulation heat exchangers. (J.S.) 3 refs.

  15. Process and apparatus for pyrolytic decomposition and coking of mixtures of finely divided solid carbonaceous material and hydrocarbon oils

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, A

    1933-09-18

    A process is described for pyrolytic decomposition and coking of mixtures of finely divided solid and semi-solid carbonaceous material and hydrocarbon oils, whereby the mixture is first heated to a high temperature; the heated products are introduced into a coking zone, where vapors are separated from nonvaporous residue afterwards to be cracked and condensed, characterized in that the mixture is heated to a high temperature under substantially noncoking conditions and that nonvaporous residue obtained in the coking zone is coked as a relatively thin layer on an externally intensely heated surface, preferably of heat-conducting, fireproof material, such as carborundum, fused-aluminum oxide, or clay.

  16. Microencapsulation by spray drying of lemon essential oil: Evaluation of mixtures of mesquite gum-nopal mucilage as new wall materials.

    Science.gov (United States)

    Cortés-Camargo, Stefani; Cruz-Olivares, Julian; Barragán-Huerta, Blanca E; Dublán-García, Octavio; Román-Guerrero, Angélica; Pérez-Alonso, César

    2017-06-01

    Mesquite gum (MG) and nopal mucilage (NM) mixtures were used for microencapsulation of lemon essential oil (LEO) by spray drying. Emulsions of MG, NM and MG-NM mixtures (25-75, 50-50, 75-25) were evaluated according to the droplet size (1.49-9.16 μm), viscosity and zeta potential (-16.07 to -20.13 mV), and microcapsules were characterised in particle size (11.9-44.4 μm), morphology, volatile oil retention (VOR) (45.9-74.4%), encapsulation efficiency (EE) (70.9-90.6%), oxidative stability and thermal analysis. The higher concentration of MG led to smaller droplet sizes and lower viscosity in the emulsions, and smaller particle sizes with the highest VOR in microcapsules. The higher concentration of NM induced to higher viscosity in the emulsions, and larger particle sizes with the highest values of EE and oxidative stability in microcapsules. This work shows evidence that MG-NM mixtures can have synergic effect in desirable characteristics such as retention and shelf life extension of LEO in microcapsules.

  17. A laboratory study of particulate and gaseous emissions from crude oil and crude oil-dispersant contaminated seawater due to breaking waves

    Science.gov (United States)

    Afshar-Mohajer, Nima; Li, Cheng; Rule, Ana M.; Katz, Joseph; Koehler, Kirsten

    2018-04-01

    Crude oil spill incidents occur frequently causing a verity of occupational, ecological and environmental problems. Dispersants are applied to enhance the dispersion rate of crude oil slicks into the water column. In this study, the aerosol size distribution from 10 nm to 20 μm, total particle-bound aromatic hydrocarbons (pPAH) and volatile organic compounds (VOCs) are measured in a 6 x 0.3 x 0.6 m tank as plunging breaking waves entrain oil slicks. The experiments are performed for seawater with slicks of crude oil, crude oil-dispersant mixture and dispersant only. The measurements investigate the effects of wave energy and slick properties on the temporal evolution of the emissions. The total number concentrations of particles originating from the oil-dispersant mixture are 1-2 orders of magnitude higher than those of crude oil across the entire nano-scale range, reaching 100x for 20 nm particles. Conversely, the differences in concentration are small in the micron range. The average concentrations of pPAH are variable but similar (150-270 ng/m3). The VOC concentrations for crude oil-dispersant mixtures are 2-3 times lower than those of crude oil, presumably due to the surfactant effect on mass diffusion. The drastic increase in ultrafine particle concentrations may raise concerns about effects of inhalation by cleanup workers and downstream communities though VOC emissions reduce. Findings through this study provide insight into how the spray of dispersant may change the ratio of airborne particulate matter and VOC emissions from seawater due to natural processes.

  18. Chilling Prospect: Climate Change Effects of Mismanaged Refrigerants in China.

    Science.gov (United States)

    Duan, Huabo; Miller, T Reed; Liu, Gang; Zeng, Xianlai; Yu, Keli; Huang, Qifei; Zuo, Jian; Qin, Yufei; Li, Jinhui

    2018-06-05

    The global community has responded to the dual threats of ozone depletion and climate change from refrigerant emissions (e.g., chlorofluorocarbons, CFCs, and hydrofluorocarbons, HFCs) in refrigerators and air conditioners (RACs) by agreeing to phase out the production of the most damaging chemicals and replacing them with substitutes. Since these refrigerants are "banked" in products during their service life, they will continue to impact our environment for decades to come if they are released due to mismanagement at the end of life. Addressing such long-term impacts of refrigerants requires a dynamic understanding of the RACs' life cycle, which was largely overlooked in previous studies. Based on field surveys and a dynamic model, we reveal the lingering ozone depletion potential (ODP) and significant global warming potential (GWP) of scrap refrigerants in China, the world's largest producer (62%) and consumer (46%) of RACs in 2015, which comes almost entirely from air conditioners rather than refrigerators. If the use and waste management of RACs continue with the current trend, the total GWP of scrap refrigerants in China will peak by 2025 at a level of 135.2 ± 18.9 Mt CO 2 e (equal to approximately 1.2% ± 0.2% of China's total greenhouse gas emissions or the national total of either The Netherlands and Czech Republic in 2015). Our results imply an urgent need for improving the recycling and waste management of RACs in China.

  19. Essential oils of culinary herbs and spices display agonist and antagonist activities at human aryl hydrocarbon receptor AhR.

    Science.gov (United States)

    Bartoňková, Iveta; Dvořák, Zdeněk

    2018-01-01

    Essential oils (EOs) of culinary herbs and spices are used to flavor, color and preserve foods and drinks. Dietary intake of EOs is significant, deserving an attention of toxicologists. We examined the effects of 31 EOs of culinary herbs and spices on the transcriptional activity of human aryl hydrocarbon receptor (AhR), which is a pivotal xenobiotic sensor, having also multiple roles in human physiology. Tested EOs were sorted out into AhR-inactive ones (14 EOs) and AhR-active ones, including full agonists (cumin, jasmine, vanilla, bay leaf), partial agonists (cloves, dill, thyme, nutmeg, oregano) and antagonists (tarragon, caraway, turmeric, lovage, fennel, spearmint, star anise, anise). Major constituents (>10%) of AhR-active EOs were studied in more detail. We identified AhR partial agonists (carvacrol, ligustilide, eugenol, eugenyl acetate, thymol, ar-turmerone) and antagonists (trans-anethole, butylidine phtalide, R/S-carvones, p-cymene), which account for AhR-mediated activities of EOs of fennel, anise, star anise, caraway, spearmint, tarragon, cloves, dill, turmeric, lovage, thyme and oregano. We also show that AhR-mediated effects of some individual constituents of EOs differ from those manifested in mixtures. In conclusion, EOs of culinary herbs and spices are agonists and antagonists of human AhR, implying a potential for food-drug interactions and interference with endocrine pathways. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Distribution and survival of Vibrio vulnificus genotypes in postharvest Gulf Coast (USA) oysters under refrigeration.

    Science.gov (United States)

    Wood, R R; Arias, C R

    2012-07-01

      The effect of refrigeration on the seafood-borne pathogen Vibrio vulnificus was investigated in terms of genotype selection and persistence in refrigerated oysters.   Naturally occurring numbers of V. vulnificus in oysters from two different locations were compared during a 2-week period under refrigeration conditions. At different time points, V. vulnificus isolates were recovered from oysters and ascribed to 16S rRNA gene type A, B or AB using restriction fragment length polymorphism. Initial V. vulnificus numbers were higher than 10(4) most probable number (MPN) g(-1) and remained unchanged throughout the duration of the study. 16S rRNA gene type B isolates accounted for 53% of the isolates recovered. Amplified fragment length polymorphism analysis confirmed the high genetic variability previously observed within this species but revealed the presence of two main genetic groups within the species that matched 16S rRNA gene ascription.   Vibrio vulnificus numbers in oysters did not significantly declined over the shelf life of the product and refrigeration did not select for specific V. vulnificus types.   The prevalence of V. vulnificus 16S rRNA gene type B in oysters was higher than previously reported from the same geographic area and was not significantly reduced during the storage period. Vibrio vulnificus is divided into two clear genotypes, regardless of the genetic marker used. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.