WorldWideScience

Sample records for oil-filled cables

  1. Compact Joint for 154kV Class XLPE and Oil-filled Cable

    Science.gov (United States)

    Gotoh, Shinichi; Tanaka, Hideo; Mituyama, Yasuichi; Niinobe, Hiroshi

    The joint of XLPE and Oil-filled cable is necessary and indispensable to meet the switch needs in replacing the oil-filled cable along with making of the underground power transmission system. However, because only connected space of the joint for the oil-filled cable is secured in narrow space of the existing manhole, the problem might be brought up to construction in the structure of the old model from the size and weight. Then, the compact joint that had reduced by about 80% of a structural size so far was developed by applying the high electric field technology according to making of EHV XLPE cable and the joint.

  2. Photoacoustic Detection of Perfluorocarbon Tracers in Air for Application to Leak Detection in Oil-Filled Cables

    Science.gov (United States)

    Zajarevich, N.; Slezak, V.; Peuriot, A.; Villa, G.; Láttero, A.; Crivicich, R.

    2013-09-01

    The underground oil-filled cable consists of a hollow copper conductor surrounded by oiled paper which acts as electrical insulation. The oil flows along the conductor and diffuses through it to the insulating paper. A lead sheath is used as the outer retaining wall. As the deterioration of this cover may cause a loss of insulation fluid, its detection is very important since this high voltage and power cable is used in cities even under sidewalks. The method of perfluorocarbon vapor tracers, based on the injection and subsequent detection of these volatile chemical substances in the vicinity of the cable, is one of the most promising methods, so far used in combination with gas chromatography and mass spectrometry. In this study, the possibility of detecting two different tracers, and , by means of resonant photoacoustic spectroscopy is studied. The beam from a tunable amplitude-modulated laser goes through an aluminum cell with quarter wave filters at both ends of an open resonator and an electret microphone in its center, attached to the walls. The calibration of the system for either substance diluted in chromatographic air showed a higher sensitivity for , so the experiment was completed checking the behavior of this substance in samples prepared with ambient air in order to analyze the application of the system to field studies.

  3. Gaussian Filtering with Tapered Oil-Filled Photonic Bandgap Fibers

    DEFF Research Database (Denmark)

    Brunetti, Anna Chiara; Scolari, Lara; Weirich, Johannes

    2008-01-01

    A tunable Gaussian filter based on a tapered oil-filled photonic crystal fiber is demonstrated. The filter is centered at X=1364nm with a bandwidth (FWHM) of 237nm. Tunability is achieved by changing the temperature of the filter. A shift of 210nm of the central wavelength has been observed by in...... by increasing the temperature from 25°C to 100°C. The measurements are compared to a simulated spectrum obtained by means of a vectorial Beam Propagation Method model....

  4. Economical Aspects of Superconducting Cable

    Science.gov (United States)

    Ohya, Masayoshi

    High-temperature superconducting (HTS) cables are expected to resolve technical problems with power grids because they put large-capacity, low-loss power transmission into a compact package. One problem is replacing old 275-kV oil filled (OF) cables with cross-linked polyethylene insulated vinyl sheath cables (XLPE cables). This is difficult because XLPE cable has a lower transmission capacity than OF cable. In addition, the high concentration of public infrastructure underground makes it extremely difficult to build new ones. However, if 66-kV HTS cables can be installed inside existing underground conduits and can achieve a power capacity equivalent to conventional 275-kV cables, construction costs could be significantly reduced. Moreover, if XLPE cables are used for a 1,000 MVA-class transmission line, then three circuits of nine 275-kV single-core cables would be required, which would incur a transmission loss of 90 W/m/cct. Three circuits of three 66-kV Three-in-One HTS cables, however, with an AC loss of 1 W/m/ph@3 kA, heat invasion of 2 W/m, and cooling system efficiency of 0.1, would reduce transmission loss to less than three-fifths that of XLPE cables.

  5. Development of a simple maintenance method for condition assessment of oil filled XLPE terminations. Diagnostic testing, oil, humidity and asset management

    Energy Technology Data Exchange (ETDEWEB)

    Liland, Knut Brede

    2011-02-15

    Development of a simple method for condition assessment of oil filled XLPE terminations An on-site/off-line prototype method for measuring water content at different positions inside oil filled high voltage cable terminations has been developed. The method consists of: 1) Measurement rod with relative humidity and temperature sensors in addition to a conductivity sensor for measuring free water in the bottom of the termination, 2) Characterisation database for three oils for converting relative humidity and temperature to absolute humidity, 3) Wireless unit for data transfer from the measurement rod to a computer and 4) Procedure for doing the measurements. The method proved to be a powerful and very simple tool in estimating the humidity and level of the oil in the termination and also detecting free water. The method was compared with more traditional and time consuming methods taking oil samples from the terminations. The agreement between the laboratory and the on-site measurements were very good. In only 10-15 minutes it was possible to diagnose the condition of the termination with respect to humidity. During the project more fundamental work studying from a provoked leakage of water into a transparent cable termination were performed by master student Geir Birkenes (NTNU) supervised by Frank Mauseth (NTNU) and Sverre Hvidsten (SINTEF Energy Research). The behavior of water droplets during leakage was visually studied and the development of the relative humidity from installed relative humidity sensors in the zero field regions below the cone was monitored on-line. Partial discharge activity (pd) was also monitored and proved that such installations are very robust. PD is not a very good method for detecting water leakage and water content in such devices due to the intermittent and in general very low discharge levels. (Author)

  6. Diagnostics of the power oil-filled transformer equipment of thermal power plants

    Science.gov (United States)

    Eltyshev, D. K.; Khoroshev, N. I.

    2016-08-01

    Problems concerning improvement of the diagnostics efficiency of the electrical facilities and functioning of the generation and distribution systems through the examples of the power oil-filled transformers, as the responsible elements referring to the electrical part of thermal power plants (TPP), were considered. Research activity is based on the fuzzy logic system allowing working both with statistical and expert information presented in the form of knowledge accumulated during operation of the power oil-filled transformer facilities. The diagnostic algorithm for various types of transformers, with the use of the intellectual estimation model of its thermal state on the basis of the key diagnostic parameters and fuzzy inference hierarchy, was developed. Criteria for taking measures allowing preventing emergencies in the electric power systems were developed. The fuzzy hierarchical model for the state assessment of the power oil-filled transformers of 110 kV, possessing high degree of credibility and setting quite strict requirements to the limits of variables of the equipment diagnostic parameters, was developed. The most frequent defects of the transformer standard elements, related with the disturbance of the isolation properties and instrumentation operation, were revealed after model testing on the real object. Presented results may be used both for the express diagnostics of the transformers state without disconnection from the power line and for more detailed analysis of the defects causes on the basis of the advanced list of the diagnostic parameters; information on those parameters may be received only after complete or partial disconnection.

  7. Research and Correlation of Diagnostic Methods for Assessment of the State of Oil Filling in Cycloid Gearbox

    Directory of Open Access Journals (Sweden)

    Petr Baron

    2015-01-01

    Full Text Available The paper describes the research in the area of the application of diagnostic methods for assessment of the state of oil filling in cycloid gearbox of robotic manipulator. The experiments were realized on request of the manufacturer of the cycloid gearbox. Primarily, the two different methods were compared: an induction, magnetic method with the use of measurement system Cosmos-Steel Dust Checker and an RTG method, XRF (X-ray fluorescent method, analyses with use of X-ray radiation. These analytical methods provide the identification and quantification of emerging Fe abrasion particles occurring in the oil filling of the redactor. The results of the experiment pointed to the unsuitability of the application of the induction magnetic method for the assessment of an actual technical state of the cycloid gearbox. The reason for this lies in specific construction of the cycloid gearbox, with characteristic high operation temperatures of the oil filling, small dimensions, high transferred power, and gear ratio.

  8. Effect of quaternary ammonium salts in the process of extracting oil filled rubber from latex

    Directory of Open Access Journals (Sweden)

    N. S. Nikulina

    2016-01-01

    Full Text Available Currently, much attention is paid to the improvement of production technology of synthetic rubber. Much attention is given to rubber is produced by emulsion polymerization. This is due to the fact that rubbers produced by emulsion polymerization have a number of positive characteristics, and are widely used in the tire and rubber industry, in composite formulations for various purposes. In recent years, the technology of production of synthetic rubbers are widely used quaternary ammonium salts which are produced on an industrial scale. Application low and high molecular weight quaternary ammonium salts to reduce pollution of environ-mental protection, exclude the use of mineral salts without significant changes in the process flowsheet. It is found that quaternary ammonium salts react with the components of the emulsion system to form insoluble complexes, which are captured produced rubber crumb. However, Applications, quaternary salts in the manufacture of oil-filled rubber in the literature sources have not been given due attention. The study presents the results of research on the effect of the concentration of a coagulating agent, tempera tours and concentration of the dispersed phase in the process of coagulation of latex in the preparation of oil-filled rubber stamps SCS-30 ARKM-15. The concentration of the coagulating agent does not significantly affect the process of separation of the rubber from the latex. The process of isolation rubber latex is advantageously carried out at a reduced temperature. The concentration of the dispersed phase also provides material effect on the coagulation process. The lead researches mouthestablished that produced rubber, rubber compounds and vulcanizates based on these indicators correspond to their requirements.

  9. Self-contained cable systems offer advantages

    Energy Technology Data Exchange (ETDEWEB)

    Morello, A.S.; Occhini, E.

    1977-05-01

    Low-pressure oil-filled (LPOF) cable systems, while seldom used in this country, have several advantages of interest to engineers. Less oil and insulating paper is required for low-pressure than for the more commonly used high-pressure systems because of the single core. The lower pessure offers safety features in the event of accidental oil loss. LPOF cables are used internationally because of their good thermal characteristics. Applications besides ac transmission lines include underground and submarine cables, such as those connecting islands with mainland facilities. Cooling can be accomplished either by circulating oil inside the central duct or circulating water through parallel nonmetallic pipes. Forced-cooling of the LPOF cables is less complicated, which allows them to have higher current ratings and makes them more adaptable to thermal transients. Conductor cooling, which increases capacity but prohibits overloads in LPOF cables, is the only system available to high voltage (HVDC) cables. Several experimental and demonstration cable systems are described. (DCK)

  10. Superconductor cable

    Science.gov (United States)

    Allais, Arnaud; Schmidt, Frank; Marzahn, Erik

    2010-05-04

    A superconductor cable is described, having a superconductive flexible cable core (1) , which is laid in a cryostat (2, 3, 4), in which the cable core (1) runs in the cryostat (2, 3, 4) in the form of a wave or helix at room temperature.

  11. Cable tensiometer

    Energy Technology Data Exchange (ETDEWEB)

    Park, B.V

    1989-05-30

    This patent describes a weight beam for measuring load on a cable. The weight beam consists of: a beam body; load cell means mounted on the beam body, the load cell means being spaced a predetermined distance from the beam body; clamp means connected to the load cell means and adapted to grip a cable whose tension is to be measured; and adjusting means connected to the load cell to deflect the cable and put the load cell under a tension load, the clamp means and the adjusting means being structurally distinct.

  12. Superconductor cable

    Science.gov (United States)

    Allais, Arnaud; Schmidt, Frank (Langenhagen, DE

    2009-12-15

    A superconductor cable includes a superconductive cable core (1) and a cryostat (2) enclosing the same. The cable core (1) has a superconductive conductor (3), an insulation (4) surrounding the same and a shielding (5) surrounding the insulation (4). A layer (3b) of a dielectric or semiconducting material is applied to a central element (3a) formed from a normally conducting material as a strand or tube and a layer (3c) of at least one wire or strip of superconductive material is placed helically on top. The central element (3a) and the layer (3c) are connected to each other in an electrically conducting manner at the ends of the cable core (1).

  13. Cable Sliding at Supports in Cable Structures

    Institute of Scientific and Technical Information of China (English)

    魏建东

    2004-01-01

    To develop an effective numerical method for the cable sliding problem in cable structures, two-node catenary cable element was built to model the cables based on analytical solution of elastic catenary. Cooperated with Newton method, continuation method was used to solve the nonlinear equations. This approach is more efficient than using Newton method only and has a wider range to select initial values for the process to converge. The relationship between the tension on a cable segment and its unstrained length was derived and used to calculate the unbalanced cable tensions at the supports. An example is presented to show the correctness and efficiency of the proposed method.

  14. On-line Monitoring System for Vapor Recovery in Oil Filling Station%加油站油气回收在线监测系统

    Institute of Scientific and Technical Information of China (English)

    孟振振; 吴锋棒; 张卫华

    2012-01-01

    In order to meet GB20952-2007 requirements and ensure vapor recovery in oil filling station, an on-line monitoring system for vapor recovery was developed. The test results from an oil filling station prove the system advantages of space saving, low cost and easy installation.%开发了加油站油气回收在线监测系统,实现了对加油站油气回收系统的在线监测,满足GB20952-2007的要求.该系统经过在模拟加油站的实验测试,已安装在中国石化北京某加油站试运行,运行效果良好,并具有占用空间小、成本低和施工安装方便的优点.

  15. VT Cable Systems 2013

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable dataset (CABLE2013) includes lines depicting the extent of Vermont's cable modem broadband system as of 6/30/2013 in addition to...

  16. Edible fat structures at high solid fat concentrations: Evidence for the existence of oil-filled nanospaces

    Science.gov (United States)

    Peyronel, Fernanda; Quinn, Bonnie; Marangoni, Alejandro G.; Pink, David A.

    2015-01-01

    We have characterized the surfaces of grain boundaries in edible oils with high solid fat content by combining ultra-small angle x-ray scattering (USAXS) with theoretical modelling and computer simulation. Our results will lead to understand the solid structures formed at the time of manufacturing fats like confectionery fats as well as pave the way for the engineering of innovative fat products. Edible fats are complex semi-solid materials where a solid structure entraps liquid oil. It was not until USAXS combined with modelling was used that the nano- to meso-structures for systems with less than 20% solids were understood. The interpretation of those results utilized models of crystalline nanoplatelets represented by rigid close-packed flat aggregates made of spheres and was allowed to aggregate using the Metropolis Monte Carlo technique. Here, we report on systems containing between 50% and 90% solids. We modelled the solid phase as being formed from seeds onto which solids condensed thereby giving rise to oil-filled nanospaces. The models predicted that the system (a) exhibits structures with fractal dimensions approximately 2, (b) a broad peak somewhat masking that slope, and (c) for smaller values of q, indications that the structures with fractal dimension approximately 2 are uniformly distributed in space. The interpretation of the experimental data was completely driven by these results. The computer simulation predictions were used in conjunction with the USAXS observations to conclude that the systems studied scattered from oil-cavities with sizes between ˜800 and ˜16 000 Å and possessed rough 2-dimensional walls.

  17. Cable Television Service; Cable Television Relay Service.

    Science.gov (United States)

    Federal Register, 1972

    1972-01-01

    The rules and regulations of the Federal Communications Commission (FCC) concerning cable television service and cable relay service are presented along with the comments of the National Cable Television Association, the National Association of Broadcasters, the Association of Maximum Service Telecasters, and a major group of program suppliers.…

  18. Cable Tensiometer for Aircraft

    Science.gov (United States)

    Nunnelee, Mark (Inventor)

    2008-01-01

    The invention is a cable tensiometer that can be used on aircraft for real-time, in-flight cable tension measurements. The invention can be used on any aircraft cables with high precision. The invention is extremely light-weight, hangs on the cable being tested and uses a dual bending beam design with a high mill-volt output to determine tension.

  19. Safer cables; Des cables plus surs

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2005-02-01

    Sixteen years after its adoption, the European construction products directive (CPD) will have soon a strong impact on the characteristics of electrical and communication cables used in European buildings and facilities. Among the six main requirements of this directive, the fire protection safety is a growing up concern and the electric cables have to be tested with respect to their fire resistance to become conformable with the directive. The cable industry has taken up the challenge. (J.S.)

  20. UtilityTelecom_CABLE2005

    Data.gov (United States)

    Vermont Center for Geographic Information — The VT Cable System dataset (CABLE2005) includes lines depicting the extent of Vermont's cable system as of 12/31/2005. Numerous cable companies provide service in...

  1. 电热油汀温升及舒适性研究%The Study on Temperature Rise and Thermal Comfort of Oil-filled Electric Heater

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    In order to solve the contradiction of oil-filled electric heater temperature rise being up to nation-al standard and meeting user comfort requirements, factors which affect heating effect are analyzed. Through con-ducting the optimization design such as oil-filled electric heater structure optimization, heating element selection optimization, the experiment results can meet the national standard for temperature rise, and meet the user′s comfort requirement, so that the result provides valuable reference to modify and design for the future.%  为解决目前电热油汀温升符合国标和满足用户舒适性要求的矛盾,本文分析影响电热油汀取暖效果的因素,通过对电热油汀结构优化、发热管选型优化等方法,经过温升测试及舒适性模拟测试证明,可以满足国家标准对温升的要求和用户的舒适性要求,为以后电热油汀的改进和优化设计提供了参考。

  2. Cable Television: Franchising Considerations.

    Science.gov (United States)

    Baer, Walter S.; And Others

    This volume is a comprehensive reference guide to cable television technology and issues of planning, franchising, and regulating a cable system. It is intended for local government officials and citizens concerned with the development of cable television systems in their communities, as well as for college and university classes in…

  3. Cable Television: Franchising Considerations.

    Science.gov (United States)

    Baer, Walter S.; And Others

    This volume is a comprehensive reference guide to cable television technology and issues of planning, franchising, and regulating a cable system. It is intended for local government officials and citizens concerned with the development of cable television systems in their communities, as well as for college and university classes in…

  4. Colleges and Cable Franchising.

    Science.gov (United States)

    Glenn, Neal D.

    After noting issues of audience appeal and financial and philosophical support for educational broadcasting, this paper urges community colleges to play an active role in the process of cable franchising. The paper first describes a cable franchise as a contract between a government unit and the cable television (CATV) company which specifies what…

  5. Cable Supported Bridges

    DEFF Research Database (Denmark)

    Gimsing, Niels Jørgen

    Cable supported bridges in the form of suspension bridges and cable-stayed bridges are distinguished by their ability to overcome large spans.The book concentrates on the synthesis of cable supported bridges, covering both design and construction aspects. The analytical part covers simple methods...

  6. Cable Television for Librarians. Cable Television Primer

    Science.gov (United States)

    Briscoe, Wallace C.

    1973-01-01

    The development of cable television, its present state, and future prospects, including a possible role for libraries, are discussed. (Other conference materials are LI 503071 and 503073 through 503084.) (SJ)

  7. Cable Tester Box

    Science.gov (United States)

    Lee, Jason H.

    2011-01-01

    Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

  8. Electrical power cable engineering

    CERN Document Server

    Thue, William A

    2011-01-01

    Fully updated, Electrical Power Cable Engineering, Third Edition again concentrates on the remarkably complex design, application, and preparation methods required to terminate and splice cables. This latest addition to the CRC Press Power Engineering series covers cutting-edge methods for design, manufacture, installation, operation, and maintenance of reliable power cable systems. It is based largely on feedback from experienced university lecturers who have taught courses on these very concepts.The book emphasizes methods to optimize vital design and installation of power cables used in the

  9. UtilityTelecom_CABLE2013

    Data.gov (United States)

    Vermont Center for Geographic Information — The VT Cable dataset (CABLE2013) includes lines depicting the extent of Vermont's cable modem broadband system as of 6/30/2013 in addition to those companies who do...

  10. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  11. Multistrand superconductor cable

    Science.gov (United States)

    Borden, Albert R.

    1985-01-01

    Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easily over one another, so as to facilitate flexing and bending of the cable, while also minimizing the possibility of causing damage to the strands by such flexing or bending. Moreover, the improved cable substantially maintains its compactness and cross-sectional shape when the cable is flexed or bent.

  12. Cable Television; A Bibliographic Review.

    Science.gov (United States)

    Schoenung, James

    This bibliographic review of publications in the field of cable television begins with an introduction to cable television and an outline of the history and development of cable television. Particular attention is given to the regulatory activities of the Federal Communications Commission and the unfulfilled potential of cable television. The…

  13. End moldings for cable dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Roose, L.D.

    1993-12-31

    End moldings for high-voltage cables are described wherein the dielectric insulator of the cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble- free cable connectors suitable for mating to premanufactured fittings are made. Disclosed are a method for making the cable connectors either in the field or in a factory, molds suitable for use with the method, and the molded cable connectors, themselves.

  14. Robotic Arm Biobarrier Cable

    Science.gov (United States)

    2008-01-01

    This image, taken by the Surface Stereo Imager on NASA's Phoenix Mars Lander on the 14th Martian day of the mission (June 7, 2008), shows the cable that held the Robotic Arm's biobarrier in place during flight has snapped. The cable's springs retracted to release the biobarrier right after landing. To the lower right of the image a spring is visible. Extending from that spring is a length of cable that snapped during the biobarrier's release. A second spring separated from the cable when it snapped and has been photographed on the ground under the lander near one of the legs. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  15. Robotic Arm Biobarrier Cable

    Science.gov (United States)

    2008-01-01

    This image, taken by the Surface Stereo Imager on NASA's Phoenix Mars Lander on the 14th Martian day of the mission (June 7, 2008), shows the cable that held the Robotic Arm's biobarrier in place during flight has snapped. The cable's springs retracted to release the biobarrier right after landing. To the lower right of the image a spring is visible. Extending from that spring is a length of cable that snapped during the biobarrier's release. A second spring separated from the cable when it snapped and has been photographed on the ground under the lander near one of the legs. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  16. Buoyant Cable Antenna System

    Science.gov (United States)

    2008-07-02

    comprise a mechanical jacket surrounding a hollow core enclosing the seismic sensor and signal transfer means. Elongated axial stress elements for...to S. H. Bittleston, discloses a semi-dry marine seismic streamer cable that consists of a number of connected streamer cable sections which each...transmitting axial loads and a radial reinforcement member for relieving radial loads are provided in the jacket . The core is filled with a fluid or fluid

  17. Modeling of cable vibration effects of cable-stayed bridges

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The analysis of dynamic responses of cable-stayed bridges subjected to wind and earthquake loads generallyconsiders only the motions of the bridge deck and pylons. The influence of the stay cable vibration on the responses of the bridgeis either ignored or considered by approximate procedures. The transverse vibration of the stay cables, which can be significant insome cases, are usually neglected in previous research. In the present study, a new three-node cable element has been developed tomodel the transverse motions of the cables. The interactions between the cable behavior and the other parts of the bridgesuperstructure are considered by the concept of dynamic stiffness. The nonlinear effect of the cable caused by its self-weight isincluded in the formulation. Numerical examples are presented to demonstrate the accuracy and efficiency of the proposed model.The impact of cable vibration behavior on the dynamic characteristics of cable-stayed bridges is discussed.

  18. Aerodynamic stability of cable-supported bridges using CFRP cables

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xin-jun; YING Lei-dong

    2007-01-01

    To gain understanding of the applicability of carbon fiber reinforced polymer (CFRP) cable in cable-supported bridges, based on the Runyang Bridge and Jinsha Bridge, a suspension bridge using CFRP cables and a cable-stayed bridge using CFRP stay cables are designed, in which the cable's cross-sectional area is determined by the principle of equivalent axial stiffness.Numerical investigations on the aerodynamic stability of the two bridges are conducted by 3D nonlinear aerodynamic stability analysis. The results showed that as CFRP cables are used in cable-supported bridges, for suspension bridge, its aerodynamic stability is superior to that of the case using steel cables due to the great increase of the torsional frequency; for cable-stayed bridge,its aerodynamic stability is basically the same as that of the case using steel stay cables. Therefore as far as the wind stability is considered, the use of CFRP cables in cable-supported bridges is feasible, and the cable's cross-sectional area should be determined by the principle of equivalent axial stiffness.

  19. AC Cable: Yokohama Project

    Science.gov (United States)

    Masuda, Takato

    High Temperature Superconducting (HTS) cables can transmit large amounts of electricity in a compact size with minimal losses. Therefore, they are expected to save the construction cost of underground lines in urban areas and decrease transmission losses. Several HTS cables have recently been demonstrated in networks around the world, and full-scale commercialization is expected in the near future. In Japan, the development of compact HTS cables suitable for urban deployment has been underway since the early 1990s. In 2007, a national project was started to verify their operational performance and long-term reliability in the grid. An HTS cable 240 m long was installed at the Asahi substation of the Tokyo Electric Power Company (TEPCO) in Yokohama; then a joint, terminations and cooling system was constructed in 2011. After successful performance tests, the cable was connected to the grid for the first time in Japan, and started to deliver electricity to 70,000 households in October 2012. This trouble-free in-grid service continued for over a year. We can conclude that the HTS cable system performs well and has the stability required for long-term in-grid operations.

  20. 30 CFR 77.605 - Breaking trailing cable and power cable connections.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Breaking trailing cable and power cable... OF UNDERGROUND COAL MINES Trailing Cables § 77.605 Breaking trailing cable and power cable connections. Trailing cable and power cable connections between cables and to power sources shall not be...

  1. Cable-Dispensing Cart

    Science.gov (United States)

    Bredberg, Alan S.

    2003-01-01

    A versatile cable-dispensing cart can support as many as a few dozen reels of cable, wire, and/or rope. The cart can be adjusted to accommodate reels of various diameters and widths, and can be expanded, contracted, or otherwise reconfigured by use of easily installable and removable parts that can be carried onboard. Among these parts are dispensing rods and a cable guide that enables dispensing of cables without affecting the direction of pull. Individual reels can be mounted on or removed from the cart without affecting the other reels: this feature facilitates the replacement or reuse of partially depleted reels, thereby helping to reduce waste. Multiple cables, wires, or ropes can be dispensed simultaneously. For maneuverability, the cart is mounted on three wheels. Once it has been positioned, the cart is supported by rubber mounts for stability and for prevention of sliding or rolling during dispensing operations. The stability and safety of the cart are enhanced by a low-center-of-gravity design. The cart can readily be disassembled into smaller units for storage or shipping, then reassembled in the desired configuration at a job site.

  2. VT Cable Modem Systems 2013

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable Modem dataset (CABLEMOD2013) includes lines depicting the extent of Vermont's cable modem broadband system as of 6/30/2013. This data...

  3. VT Cable Modem Systems 2005

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The VT Cable Modem dataset (CABLEMOD2005) includes lines depicting the extent of Vermont's cable modem broadband system as of 12/31/2005. This...

  4. Cable historical operating temperature estimator

    Energy Technology Data Exchange (ETDEWEB)

    Leon de, F.; St-Roch, P.; Beauregard, C. [Cyme International, St-Bruno, PQ (Canada)

    2006-07-01

    A tool designed to accurately determine the thermal age of underground cables was described. The cable historical operating temperature estimate (CHOTE) is a software application designed to identify which cables have exceeded their normal and emergency operating temperatures. CHOTE is also capable of predicting when cables are likely to reach their maximum design temperature in the future. The system operates by processing archived loading information from data acquisition systems in order to automatically analyze all the thermal sections of a system. Cables that exceed their emergency and normal temperatures for the longest amount of time are ranked first, and outputs display when and where the hot spots have occurred. CHOTE is also able to study the impact of the addition of new cables and to determine the remaining ampacity of cables installed in a given duct bank. It was concluded that the CHOTE system can help in the efficient management of cable repairs and installations. 28 refs., 7 figs.

  5. Space Flight Cable Model Development

    Science.gov (United States)

    Spak, Kaitlin

    2013-01-01

    This work concentrates the modeling efforts presented in last year's VSGC conference paper, "Model Development for Cable-Harnessed Beams." The focus is narrowed to modeling of space-flight cables only, as a reliable damped cable model is not yet readily available and is necessary to continue modeling cable-harnessed space structures. New experimental data is presented, eliminating the low-frequency noise that plagued the first year's efforts. The distributed transfer function method is applied to a single section of space flight cable for Euler-Bernoulli and shear beams. The work presented here will be developed into a damped cable model that can be incorporated into an interconnected beam-cable system. The overall goal of this work is to accurately predict natural frequencies and modal damping ratios for cabled space structures.

  6. The Danish Superconducting Cable Project

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1997-01-01

    The design and construction of a superconducting cable is described. The cable has a room temperature dielectric design with the cryostat placed inside the electrical insulation.BSCCO 2223 superconducting tapes wound in helix form around a former are used as the cable conductor. Results from...

  7. High Temperature Superconducting Underground Cable

    Energy Technology Data Exchange (ETDEWEB)

    Farrell, Roger, A.

    2010-02-28

    The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

  8. 30 CFR 75.607 - Breaking trailing cable and power cable connections.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Breaking trailing cable and power cable... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.607 Breaking trailing cable and power cable connections. Trailing cable and power cable connections...

  9. Pediatrics and Cable Television.

    Science.gov (United States)

    Wallerstein, Edward; And Others

    The Department of Community Medicine of the Mount Sinai School of Medicine (New York City), in cooperation with the TelePrompTer Corporation and with funding from the Health Services and Mental Health Administration of the Department of Health, Education, and Welfare, has developed a bidirectional television system using coaxial cable which links…

  10. Cable Aerodynamic Control

    DEFF Research Database (Denmark)

    Kleissl, Kenneth

    to a categorization of the different control technics together with an identification of two key mechanisms for reduction of the design drag force. During this project extensive experimental work examining the aerodynamics of the currently used cable surface modifications together with new innovative proposals have...

  11. Comparison of cable ageing

    Science.gov (United States)

    Plaček, Vít; Kohout, Tomáš

    2010-03-01

    Two cable types, which currently are used in nuclear power plants (NPP) and which are composed by jacket/insulation materials, i.e. PVC/PVC and PVC/PE, were exposed to accelerated ageing conditions, in order to simulate their behavior after 10 years in service. The cables were aged under two different test conditions: With relatively high accelerating ageing speed:Radiation ageing was carried out at room temperature at a dose rate of 2900 Gy/h, followed by thermal ageing at 100 °C. This accelerated ageing condition was fairly fast, but still in compliance with the standards. With moderate ageing speed:The radiation and thermal ageing was performed simultaneously (superimposed) at a dose rate of 2.7-3.7Gy/h and a temperature of 68-70 °C. Such a test condition seems to be very close to the radiation and temperature impact onto the cables in the real NPP service. Finally, mechanical properties were measured to characterize the ageing status of the cables. The purpose of this study was to compare degradation effects, derived from both ageing methods, and to demonstrate that results obtained from high values of accelerating parameters and from fast ageing simulation can be very different from reality. The observed results corroborated this assumption.

  12. Lightweight Electric Power Cable.

    Science.gov (United States)

    1982-09-01

    8I~ .4 111 162 MICROCi Pi RL’ LUHION TESI CHARI "LIGHTWEIGHT ELECTRIC POWER CABLE" FINAL TECHNICAL REPORT SEPTEMBER 30, 1981 to SEPTEMBER 30, 1982... Vulcanized by heat to crosslink. TPE (Thermoplastic Elastomer) - Polymers having elastomeric proper- ties. Used as thermoplastics - melt formed by

  13. Handbook for photovoltaic cabling

    Energy Technology Data Exchange (ETDEWEB)

    Klein, D. N.

    1980-08-01

    This volume, originally written as part of the Interim Performance Criteria Document Development Implementation Plan and Procedures for Photovoltaic Energy Systems, is an analysis of the several factors to be considered in selecting cabling for photovoltaic purposes. These factors, correspoonding to chapter titles, are electrical, structural, safety, durability/reliability, and installation. A glossary of terms used within the volume is included for reference.

  14. Flat conductor cable commercialization project

    Science.gov (United States)

    Hogarth, P.; Wadsworth, E.

    1977-01-01

    An undercarpet flat conductor cable and a baseboard flat conductor cable system were studied for commercialization. The undercarpet system is designed for use in office and commercial buildings. It employs a flat power cable, protected by a grounded metal shield, that terminates in receptacles mounted on the floor. It is designed to interface with a flat conductor cable telephone system. The baseboard system consists of a flat power cable mounted in a plastic raceway; both the raceway and the receptacles are mounted on the surface of the baseboard. It is designed primarily for use in residential buildings, particularly for renovation and concrete and masonry construction.

  15. Tapping the television cable.

    Science.gov (United States)

    Clarke, M; Findlay, A; Canac, J F; Vergez, A

    1996-01-01

    Immediate access to patient data is essential to support good clinical decision making and support. However, away from the surgery, the doctor is currently unable to have any access to the clinical database. Solutions exist to support remote access, such as modems or radio data networks, but these are slow, with typical speeds in the 2-10 kbaud region. We propose a novel solution, to use the TV cable already installed in many homes. Using this technology, a suitably equipped computer (RF modern) is capable of connecting at speeds in excess of 500 kbaud and will run applications in exactly the same way as if connected to a surgery network: the cable TV becomes a LAN, but on a metropolitan scale. Brunel University, in collaboration with the Cable Corporation, has been piloting such a network. Issues include not only levels of service, but also security on the network and access, since the data are being effectively received in every home. However, close scrutiny of channel use can create closed networks reserved for specific users. The technology involves use of an RF modem to transmit data on a reverse channel (based at 16 MHz) on each subnet to a router at the head end of the cable network. This frequency translates the packet and retransmits it to all the subnets on a forward channel (based at 178 MHz). Each channel occupies the bandwidth normally allocated to one TV channel. Access is based on a modified CSMA/CD protocol, so treating the cable network as single multiple access network. The modem comes as a standard card installed in a PC and appears much as an ethernet card, but at reduced speed. With an NDIS driver it is quite able to support almost any network software, and has successfully demonstrated Novell and TCP/IP. We describe the HomeWorker network and the results from a pilot study being undertaken to determine the performance of the system and its impact on working practice.

  16. Method to improve superconductor cable

    Science.gov (United States)

    Borden, A.R.

    1984-03-08

    A method is disclosed of making a stranded superconductor cable having improved flexing and bending characteristics. In such method, a plurality of superconductor strands are helically wound around a cylindrical portion of a mandrel which tapers along a transitional portion to a flat end portion. The helically wound strands form a multistrand hollow cable which is partially flattened by pressure rollers as the cable travels along the transitional portion. The partially flattened cable is impacted with repeated hammer blows as the hollow cable travels along the flat end portion. The hammer blows flatten both the internal and the external surfaces of the strands. The cable is fully flattened and compacted by two sets of pressure rollers which engage the flat sides and the edges of the cable after it has traveled away from the flat end portion of the mandrel. The flattened internal surfaces slide easily over one another when the cable is flexed or bent so that there is very little possibility that the cable will be damaged by the necessary flexing and bending required to wind the cable into magnet coils.

  17. EIGENFREQUENCY ANALYSIS OF CABLE STRUCTURES WITH INCLINED CABLES

    Institute of Scientific and Technical Information of China (English)

    William Paulsen; Greg Slayton

    2006-01-01

    The approximate eigenfrequencies for the in-plane vibrations of a cable structure consisting of inclined cables, together with point masses at various points were computed. It was discovered that the classical transfer matrix method was inadequate for this task, and hence the larger exterior matrices were used to determine the eigenfrequency equation. Then predictions of the dynamics of the general cable structure based on the asymptotic estimates of the exterior matrices were made.

  18. 14 CFR 23.689 - Cable systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cable systems. 23.689 Section 23.689... Systems § 23.689 Cable systems. (a) Each cable, cable fitting, turnbuckle, splice, and pulley used must meet approved specifications. In addition— (1) No cable smaller than 1/8 inch diameter may be used...

  19. Cable networks, services, and management

    CERN Document Server

    2015-01-01

    Cable Networks, Services, and Management is the first book to cover cable networks, services, and their management, in-depth, for network operators, engineers, researchers, and students. Thirteen experts in various fields have contributed their knowledge of network architectures and services, Operations, Administration, Maintenance, Provisioning, Troubleshooting (OAMPT) for residential and business services, cloud, Software Defined Networks (SDN), as well as virtualization concepts and their applications as part of the future directions of cable networks. The book begins by introducing architecture and services for Data Over Cable Service Interface Specification (DOCSIS) 3.0/ 3.1, Converged Cable Access Platform (CCAP), Content Distribution Networks (CDN, IP TV, and Packet Cable and Wi-Fi for Residential Services. Topics that are discussed in proceeding chapters include: operational systems and management architectures, service orders, provisioning, fault manageme t, performance management, billing systems a...

  20. Technology for long cable erection of a thousand-meter scale cable-stayed bridge

    Institute of Scientific and Technical Information of China (English)

    Rao Huarong; Deng Huibin

    2009-01-01

    In the background of the construction of Sutong Yangtze River Bridge (short as Sutong Bridge), the cable construction method and techniques of a thousand-meter scale cable-stayed bridge are introduced. Some key construction techniques, such as outspreading cable on deck, installing cable at pylon, pulling and fixing cable at the attachment with decks and cable PE sheath protection are discussed.

  1. Dynamic testing of cable structures

    Directory of Open Access Journals (Sweden)

    Caetano Elsa

    2015-01-01

    Full Text Available The paper discusses the role of dynamic testing in the study of cable structures. In this context, the identification of cable force based on vibration measurements is discussed. Vibration and damping assessment are then introduced as the focus of dynamic monitoring systems, and particular aspects of the structural behaviour under environmental loads are analysed. Diverse application results are presented to support the discussion centred on cable-stayed bridges, roof structures, a guyed mast and a transmission line.

  2. Cable Bacteria in Freshwater Sediments

    OpenAIRE

    Risgaard-Petersen, Nils; Kristiansen, Michael; Frederiksen, Rasmus B.; Dittmer, Anders Lindequist; Bjerg, Jesper Tataru; Trojan, Daniela; Schreiber, Lars; Damgaard, Lars Riis; Schramm, Andreas; Nielsen, Lars Peter

    2015-01-01

    In marine sediments cathodic oxygen reduction at the sediment surface can be coupled to anodic sulfide oxidation in deeper anoxic layers through electrical currents mediated by filamentous, multicellular bacteria of the Desulfobulbaceae family, the so-called cable bacteria. Until now, cable bacteria have only been reported from marine environments. In this study, we demonstrate that cable bacteria also occur in freshwater sediments. In a first step, homogenized sediment collected from the fre...

  3. Electromagnetic transients in power cables

    CERN Document Server

    da Silva, Filipe Faria

    2013-01-01

    From the more basic concepts to the most advanced ones where long and laborious simulation models are required, Electromagnetic Transients in Power Cables provides a thorough insight into the study of electromagnetic transients and underground power cables. Explanations and demonstrations of different electromagnetic transient phenomena are provided, from simple lumped-parameter circuits to complex cable-based high voltage networks, as well as instructions on how to model the cables.Supported throughout by illustrations, circuit diagrams and simulation results, each chapter contains exercises,

  4. STATIC ANALYSIS OF CABLE STRUCTURE

    Institute of Scientific and Technical Information of China (English)

    HUANG Yan; LAN Wei-ren

    2006-01-01

    Based on the nonlinear geometric relation between strain and displacement for flexible cable, the equilibrium equation under self-weight and influence of temperature was established and an analytical solution of displacement and tension distribution defined in Eulerian coordinate system was accurately obtained. The nonlinear algebraic equations caused by cable structure were solved directly using the modified Powell hybrid algorithm with high precision routine DNEQNE of Fortran. For example, a cable structure consisting of three cables jointly supported by a vertical spring and all the other ends fixed was calculated and compared with various methods by other scholars.

  5. Cable ampacity. A Finnish perspective

    Energy Technology Data Exchange (ETDEWEB)

    Millar, R.J.; Lehtonen, M.

    2006-07-01

    This report is primarily the practical application of a new method to calculate cable conductor temperatures in real time. A brief summary of various thermal parameter measurements in southern Finland is provided, an algorithm to compute cable temperatures in real time when both moisture migration and overall moisture content change are occurring is outlined, potential outcomes of extended loading are demonstrated, installation configurations are compared, steady-state and cyclic ratings are given for HV and MV installations, and emergency loading scenarios are evaluated. A more rational approach to cable rating in Finnish conditions is established. Conservative transient-based rating tends to give back the ampacity that might be lost due to worst possible environmental conditions for installed cables. Nevertheless, it is suggested that MV cables be derated by 20 % from their nominal catalogue ratings. orig.)

  6. Length of a Hanging Cable

    Directory of Open Access Journals (Sweden)

    Eric Costello

    2011-01-01

    Full Text Available The shape of a cable hanging under its own weight and uniform horizontal tension between two power poles is a catenary. The catenary is a curve which has an equation defined by a hyperbolic cosine function and a scaling factor. The scaling factor for power cables hanging under their own weight is equal to the horizontal tension on the cable divided by the weight of the cable. Both of these values are unknown for this problem. Newton's method was used to approximate the scaling factor and the arc length function to determine the length of the cable. A script was written using the Python programming language in order to quickly perform several iterations of Newton's method to get a good approximation for the scaling factor.

  7. Cable Bacteria in Freshwater Sediments

    DEFF Research Database (Denmark)

    Risgaard-Petersen, Nils; Kristiansen, Michael; Frederiksen, Rasmus

    2015-01-01

    In marine sediments cathodic oxygen reduction at the sediment surface can be coupled to anodic sulfide oxidation in deeper anoxic layers through electrical currents mediated by filamentous, multicellular bacteria of the Desulfobulbaceae family, the so-called cable bacteria. Until now, cable...... marine cable bacteria, with the genus Desulfobulbus as the closest cultured lineage. The results of the present study indicate that electric currents mediated by cable bacteria could be important for the biogeochemistry in many more environments than anticipated thus far and suggest a common evolutionary...... bacteria have only been reported from marine environments. In this study, we demonstrate that cable bacteria also occur in freshwater sediments. In a first step, homogenized sediment collected from the freshwater stream Giber Å, Denmark, was incubated in the laboratory. After 2 weeks, pH signatures...

  8. Photonic-powered cable assembly

    Science.gov (United States)

    Sanderson, Stephen N.; Appel, Titus James; Wrye, IV, Walter C.

    2013-01-22

    A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

  9. Cable Bacteria in Freshwater Sediments.

    Science.gov (United States)

    Risgaard-Petersen, Nils; Kristiansen, Michael; Frederiksen, Rasmus B; Dittmer, Anders Lindequist; Bjerg, Jesper Tataru; Trojan, Daniela; Schreiber, Lars; Damgaard, Lars Riis; Schramm, Andreas; Nielsen, Lars Peter

    2015-09-01

    In marine sediments cathodic oxygen reduction at the sediment surface can be coupled to anodic sulfide oxidation in deeper anoxic layers through electrical currents mediated by filamentous, multicellular bacteria of the Desulfobulbaceae family, the so-called cable bacteria. Until now, cable bacteria have only been reported from marine environments. In this study, we demonstrate that cable bacteria also occur in freshwater sediments. In a first step, homogenized sediment collected from the freshwater stream Giber Å, Denmark, was incubated in the laboratory. After 2 weeks, pH signatures and electric fields indicated electron transfer between vertically separated anodic and cathodic half-reactions. Fluorescence in situ hybridization revealed the presence of Desulfobulbaceae filaments. In addition, in situ measurements of oxygen, pH, and electric potential distributions in the waterlogged banks of Giber Å demonstrated the presence of distant electric redox coupling in naturally occurring freshwater sediment. At the same site, filamentous Desulfobulbaceae with cable bacterium morphology were found to be present. Their 16S rRNA gene sequence placed them as a distinct sister group to the known marine cable bacteria, with the genus Desulfobulbus as the closest cultured lineage. The results of the present study indicate that electric currents mediated by cable bacteria could be important for the biogeochemistry in many more environments than anticipated thus far and suggest a common evolutionary origin of the cable phenotype within Desulfobulbaceae with subsequent diversification into a freshwater and a marine lineage.

  10. 10BASE5 Ethernet Cable & Vampire Tap

    CERN Multimedia

    1983-01-01

    10BASE5 Thick Ethernet Cable, 10Mbit/sec. In the 1980s and early 1990's, Ethernet became more popular and provided a much faster data transmission rate. This cable is one of the first ethernet cables from 1983, a thick, bulky affair. Computers were attached via "Vampire Taps" which were connectors screwed straight through the shielding of the cable.

  11. 14 CFR 27.1365 - Electric cables.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electric cables. 27.1365 Section 27.1365... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 27.1365 Electric cables. (a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would...

  12. Cable Television, Market Power and Regulation.

    Science.gov (United States)

    Thorpe, Kenneth E.

    The goals of this dissertation are to provide an empirical examination of the impact of competing technologies on cable television firms and to document existing pricing behavior in the cable and pay programming industry. The introduction provides a brief overview of the cable television industry, including the impact of cable on federal policy…

  13. Cable Television: Citizen Participation in Planning.

    Science.gov (United States)

    Yin, Robert K.

    The historical background of citizen participation in local affairs and its relevance at the onset of community concern about cable television are briefly discussed in this report. The participation of citizens, municipal officials, and cable operators in laying the groundwork for a cable system as well as the pros and cons of cable television as…

  14. 14 CFR 25.689 - Cable systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Cable systems. 25.689 Section 25.689... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.689 Cable systems. (a) Each cable, cable fitting, turnbuckle, splice, and pulley must be approved. In addition— (1) No...

  15. Superconducting cable connections and methods

    Energy Technology Data Exchange (ETDEWEB)

    van der Laan, Daniel Cornelis

    2017-09-05

    Superconducting cable connector structures include a terminal body (or other structure) onto which the tapes from the superconducting cable extend. The terminal body (or other structure) has a diameter that is sufficiently larger than the diameter of the former of the superconducting cable, so that the tapes spread out over the outer surface of the terminal body. As a result, gaps are formed between tapes on the terminal body (or other structure). Those gaps are filled with solder (or other suitable flowable conductive material), to provide a current path of relatively high conductivity in the radial direction. Other connector structures omit the terminal body.

  16. Thermal analysis of underground power cable system

    Science.gov (United States)

    Rerak, Monika; Ocłoń, Paweł

    2017-10-01

    The paper presents the application of Finite Element Method in thermal analysis of underground power cable system. The computations were performed for power cables buried in-line in the ground at a depth of 2 meters. The developed mathematical model allows determining the two-dimensional temperature distribution in the soil, thermal backfill and power cables. The simulations studied the effect of soil and cable backfill thermal conductivity on the maximum temperature of the cable conductor. Also, the effect of cable diameter on the temperature of cable core was studied. Numerical analyses were performed based on a program written in MATLAB.

  17. Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables

    Directory of Open Access Journals (Sweden)

    Xu Xie

    2014-06-01

    Full Text Available In this study, the scope of CFRP cables in cable-stayed bridges is studied by establishing a numerical model of a 1400-m span of the same. The mechanical properties and characteristics of CFRP stay cables and of a cable-stayed bridge with CFRP cables are here subjected to comprehensive analysis. The anomalies in the damping properties of free vibration, nonlinear parametric vibration and wind fluctuating vibration between steel cables and CFRP cables are determined. The structural stiffness, wind resistance and traffic vibration of the cable-stayed bridge with CFRP cables are also analyzed. It was found that the static performances of a cable-stayed bridge with CFRP cables and steel cables are basically the same. The natural frequencies of CFRP cables do not coincide with the major natural frequencies of the cable-stayed bridge, so the likelihood of CFRP cable-bridge coupling vibration is minuscule. For CFRP cables, the response amplitudes of both parametric vibration and wind fluctuating vibration are smaller than those of steel cables. It can be concluded from the research that the use of CFRP cables does not change the dynamic characteristics of the vehicle-bridge coupling vibration. Therefore, they can be used in long-span cable-stayed bridges with an excellent mechanical performance.

  18. Electromagnetic Transients in Power Cables

    DEFF Research Database (Denmark)

    Silva, Filipe Faria Da; Bak, Claus Leth

    of the method. The chapter continues by analysing the frequency-spectrums of cable-based networks which have lower resonance frequencies than usual because of the larger capacitance of the cables. At the same time, a technique that may help save time when plotting the frequency spectrum of a network is proposed...... typically used for the screens of cables (both-ends bonding and cross-boding) and also presents methods that can be used to estimate the maximum current of a cable for different types of soils, i.e. thermal calculations. The end of the chapter introduces the shunt reactor, which is an important element....... It is true that in many cases, software is used to run simulations, and the reader may be tempted to think that only those designing the software need to know how to use modal theory. However, several phenomena require at least a minimum knowledge of the topic and for that reason, the book provides...

  19. Motility of electric cable bacteria

    DEFF Research Database (Denmark)

    Bjerg, Jesper Tataru; Damgaard, Lars Riis; Holm, Simon Agner

    2016-01-01

    Cable bacteria are filamentous bacteria that electrically couple sulfide oxidation and oxygen reduction at centimeter distances, and observations in sediment environments have suggested that they are motile. By time-lapse microscopy, we found that cable bacteria used gliding motility on surfaces...... with a highly variable speed of 0.50.3 ms1 (meanstandard deviation) and time between reversals of 155108 s. They frequently moved forward in loops, and formation of twisted loops revealed helical rotation of the filaments. Cable bacteria responded to chemical gradients in their environment, and around the oxic......-anoxic interface, they curled and piled up, with straight parts connecting back to the source of sulfide. Thus, it appears that motility serves the cable bacteria in establishing and keeping optimal connections between their distant electron donor and acceptors in a dynamic sediment environment....

  20. Nuclear instrumentation cable end seal

    Science.gov (United States)

    Cannon, Collins P.; Brown, Donald P.

    1979-01-01

    An improved coaxial end seal for hermetically sealed nuclear instrumentation cable exhibiting an improved breakdown pulse noise characteristic under high voltage, high temperature conditions. A tubular insulator body has metallized interior and exterior surface portions which are braze sealed to a center conductor and an outer conductive sheath. The end surface of the insulator body which is directed toward the coaxial cable to which it is sealed has a recessed surface portion within which the braze seal material terminates.

  1. ELECTROSTATIC PROCESSES IN POWER CABLES

    Directory of Open Access Journals (Sweden)

    G.V. Bezprozvannych

    2013-09-01

    Full Text Available Observation of contact electrification of power cable samples is made. It is revealed that the contact potential difference and the capacity formed under separation of free charges on the surfaces of the contacting materials depend on cable design, applied materials, and inspection schemes. Time series of capacity drift and dielectric loss tangent caused by instability of triboelectric charging of the contacting surfaces are presented.

  2. Brookhaven superconducting cable test facility

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, E.B.; Gibbs, R.J.

    1976-08-17

    Construction has started on an outdoor testing station for flexible ac superconducting power transmission cables. It is intended to serve as an intermediate step between laboratory-scale experiments and qualification testing of prototype-scale cables. The permanent equipment includes a 500 W supercritical helium refrigerator using a screw compressor and multistage turbine expanders. Helium storage for 250,000 cu ft of helium at 250 psi is provided. Initially, the cables will be tested in a horizontal cryostat some 250 ft long. High-voltage 60 Hz tests will be performed with the cable in a series resonant mode with a maximum line to ground capability of 240 kV, this is adequate for a 138 kV system design. Impulse testing up to about 650 kV is planned. The cable conductor will be energized by current transformers, initially at about 4 kA and later up to fault levels of 40 kA. The refrigerator is now at the site and testing on a dummy load will commence in the Fall of 1976. The cryostat will be installed in 1977 followed about a year later by the first cable tests.

  3. Parametric Vibration and Vibration Reduction of Cables in Cable-stayed Space Latticed Structure

    Institute of Scientific and Technical Information of China (English)

    BAO Yan; ZHOU Dai; LIU Jie

    2008-01-01

    Mechanical model and vibration equation of a cable in cable-stayed sparse latticed structure (CSLS) under external axial excitation were founded. Determination of the mass lumps and natural frequencies supplied by the space latticed structure (SLS) was analyzed. Multiple scales method (MSM) was introduced to analyze the characteristics of cable's parametric vibration, and the precise time-integration method (PTIM) was used to solve vibration equation. The vibration behavior of a cable is closely relative to the frequency ratio of the cable and SLS. The cable's parametric vibration caused by the external axial excitation easily occurs if the frequency ratio of the cable and SLS is in a certain range, and the cable's vibration amplitude varies greatly even if the initial disturbance supplied by SLS changes a little. Furthermore, the mechanical model and vibration equation of the composite cable system consisting of main cables and assistant cables were studied. The parametric analysis such as the pre-tension level and arrangement of the assistant cables was carried out. Due to the assistant cables, the single-cable vibration mode can be transferred to the global vibration mode, and the stiffness and damping of the cable system are enhanced. The natural frequencies of the composite cable system with the curve line arrangement of assistant cables are higher than those with the straight-line arrangement and the former is more effective than the latter on the cable's vibration suppression.

  4. Optical Measurement of Cable and String Vibration

    Directory of Open Access Journals (Sweden)

    Y. Achkire

    1998-01-01

    Full Text Available This paper describes a non contacting measurement technique for the transverse vibration of small cables and strings using an analog position sensing detector. On the one hand, the sensor is used to monitor the cable vibrations of a small scale mock-up of a cable structure in order to validate the nonlinear cable dynamics model. On the other hand, the optical sensor is used to evaluate the performance of an active tendon control algorithm with guaranteed stability properties. It is demonstrated experimentally, that a force feedback control law based on a collocated force sensor measuring the tension in the cable is feasible and provides active damping in the cable.

  5. A Novel Oil-Filling and Coupling Method Based on Phase Manipulation for Electrofluidic Displays%基于相变操控的电润湿显示油墨填充与封装工艺研究

    Institute of Scientific and Technical Information of China (English)

    唐彪; 蒋洪伟; 郭媛媛; Robert A.HAYES; 周国富

    2016-01-01

    Color oil filling and coupling are critical parts of electrofluidic display fabrication process.How to im-prove the uniformity and efficiency of the filling process is still a critical challenge for electrofluidic displays tech-nology.A novel oil filling and coupling approach based on phase manipulation is proposed in this paper, which al-lows the filling conducting in the atmospheric environment, while carrying out the coupling in the liquid environ-ment with the oil in frozen condition.The complexity caused by oil/water/solid interface manipulation in traditional filling method is avoided in this proposed approach, which improves the stability and compatibility of the filling process.The oil thickness analysis indicates the phased manipulation filling method giving a better controllability compared to traditional self-assembly method.The electro-optical response performance of the display device using phase manipulating method is comparable with that using normal process.This work provides a powerful method for overcoming the filling and coupling bottleneck in electrofluidic display manufacturing, and will accelerate the com-mercialization of electrofluidic display technology.%文章提出一种基于相变操控的电润湿显示油墨创新填充和封装方法,即在空气环境中完成油墨液相填充,经低温凝固后投入液体环境完成封装。该方法有效规避了在传统液下环境中填充涉及的油/水/固三相界面操控的复杂性,提高了填充工艺的兼容性和稳定性。对油墨厚度的分析结果表明,基于相变操控填充油墨厚度与像素墙高度的相关性更好,较传统自组装填充具有更好的膜厚控制性。相变操控填充电润湿显示器件的光电响应处于合理水平。该研究有效解决了电润湿显示油墨填充的技术瓶颈,对推进电润湿显示技术的应用具有重要意义。

  6. Umbilical Cable Recovery Load Analysis

    Institute of Scientific and Technical Information of China (English)

    YAN Shu-wang; JIA Zhao-lin; FENG Xiao-wei; LI Shi-tao

    2013-01-01

    Umbilical cable is a kind of integrated subsea cable widely used in the exploration and exploitation of oil and gas field.The severe ocean environment makes great challenges to umbilical maintenance and repair work.Damaged umbilical is usually recovered for the regular operation of the offshore production system.Analysis on cables in essence is a two-point boundary problem.The tension load at the mudline must be known first,and then the recovery load and recovery angle on the vessel can be solved by use of catenary equation.The recovery analysis also involves umbilicalsoil interaction and becomes more complicated.Calculation methods for recovery load of the exposed and buried umbilical are established and the relationship between the position of touch down point and the recovery load as well as the recovery angle and recovery load are analyzed.The analysis results provide a theoretical reference for offshore on-deck operation.

  7. Umbilical cable recovery load analysis

    Science.gov (United States)

    Yan, Shu-wang; Jia, Zhao-lin; Feng, Xiao-wei; Li, Shi-tao

    2013-06-01

    Umbilical cable is a kind of integrated subsea cable widely used in the exploration and exploitation of oil and gas field. The severe ocean environment makes great challenges to umbilical maintenance and repair work. Damaged umbilical is usually recovered for the regular operation of the offshore production system. Analysis on cables in essence is a two-point boundary problem. The tension load at the mudline must be known first, and then the recovery load and recovery angle on the vessel can be solved by use of catenary equation. The recovery analysis also involves umbilical-soil interaction and becomes more complicated. Calculation methods for recovery load of the exposed and buried umbilical are established and the relationship between the position of touch down point and the recovery load as well as the recovery angle and recovery load are analyzed. The analysis results provide a theoretical reference for offshore on-deck operation.

  8. Cable Television: From Here to Where?

    Science.gov (United States)

    Canadian Cable Television Association, Ottawa (Ontario).

    A brief description is presented of the present uses, regulatory structure, and future potentials of cable television for Canada. Some 30% of Canada is already wired for cable, as opposed to 9% in the United States. (RH)

  9. Repairing Damaged Power-Cable Insulation

    Science.gov (United States)

    Baker, G. E.

    1984-01-01

    Simple method saves time, money, and material. In new method cable remains in place while new insulation is applied to damaged portion. Method results in new terminations with safety factor equal to that of any portion of cable.

  10. A cable position sorting method for the balance of current distribution of parallel connected cables

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.Y. [Northern Taiwan Inst. of Science and Technology, Taipei, Taiwan (China); Yu, C.S. [National Defence Univ., Taoyuan, Taiwan (China); Wang, S.C. [Lung Hwa Univ. of Science and Technology, Taoyuan, Taiwan (China); Chen, Y.L. [MingChi Univ. of Technology, Taipei, Taiwan (China)

    2006-07-01

    In order to meet the high ampacity requirement of a low voltage main feeder, single-core power cables are usually connected in parallel in Taiwan's industrial and commercial power distribution systems. However, parallel connected cables can be problematic due to unequal current distributions among cables of the same phase, causing excessive temperature rise in the heavier loading cables, thus reducing the life expectancy of cable insulation. One of the most effective and economical methods of balancing current distributions is a properly designed cable position arrangement. This paper proposed a cable position sorting method for the balance of current distribution of parallel connected cables. A current distribution calculation method was developed based on mutual inductance theorem and the numerical iteration technique. In order to implement the sorting algorithm, two current distribution indices were proposed for the power loss of all cables and for the largest cable current value. The index values of different cable arrangement patterns generated by a novel permutation reduction method were determined and sorted and 3 cable configurations were studied. Recommendations for the arrangement of cable positions, aiming for more balanced current distributions, were also presented. It was concluded that dividing the cables into subgroups, including only one cable per phase in a subgroup, and arranging the cables in symmetric form can achieve a very balanced current distribution. 5 refs., 14 tabs., 7 figs.

  11. 47 CFR 76.640 - Support for unidirectional digital cable products on digital cable systems.

    Science.gov (United States)

    2010-10-01

    ... products on digital cable systems. 76.640 Section 76.640 Telecommunication FEDERAL COMMUNICATIONS... Standards § 76.640 Support for unidirectional digital cable products on digital cable systems. (a) The requirements of this section shall apply to digital cable systems. For purposes of this section, digital...

  12. Online Cable Tester and Rerouter

    Science.gov (United States)

    Lewis, Mark; Medelius, Pedro

    2012-01-01

    Hardware and algorithms have been developed to transfer electrical power and data connectivity safely, efficiently, and automatically from an identified damaged/defective wire in a cable to an alternate wire path. The combination of online cable testing capabilities, along with intelligent signal rerouting algorithms, allows the user to overcome the inherent difficulty of maintaining system integrity and configuration control, while autonomously rerouting signals and functions without introducing new failure modes. The incorporation of this capability will increase the reliability of systems by ensuring system availability during operations.

  13. IntelliCable Interface Specification

    Science.gov (United States)

    2016-07-14

    manager on how to use this. Some will factor the priority into account and always consume the highest priority while others...Battlefield Air Operations power manager uses a 10 pin Glenair Mighty Mouse connector with default keying . Pin 9 is specified as the IntelliCable pin. A BAO...standard Soldier Power Manager uses a 7 pin Glenair Mighty Mouse Connector, using alternative keying distinct from the Land Warrior battery specification, and the Li-145 battery. Pin 3 is defined as the IntelliCable pin.

  14. Motility of Electric Cable Bacteria

    OpenAIRE

    Bjerg, Jesper Tataru; Damgaard, Lars Riis; Holm, Simon Agner; Schramm, Andreas; Nielsen, Lars Peter

    2016-01-01

    Cable bacteria are filamentous bacteria that electrically couple sulfide oxidation and oxygen reduction at centimeter distances, and observations in sediment environments have suggested that they are motile. By time-lapse microscopy, we found that cable bacteria used gliding motility on surfaces with a highly variable speed of 0.5 ± 0.3 μm s−1 (mean ± standard deviation) and time between reversals of 155 ± 108 s. They frequently moved forward in loops, and formation of twisted loops revealed ...

  15. North American Submarine Cable Association (NASCA) Submarine Cables

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data show the locations of in-service and out-of-service submarine cables that are owned by members of NASCA and located in U.S. territorial waters. More...

  16. Remote Acquisition Amplifier For 50-Ohm Cable

    Science.gov (United States)

    Amador, Jose J.

    1995-01-01

    Buffer-amplifier unit designed to drive 50-Ohm cables up to 100 ft. (30 m) long, compensating for attenuation in cables and enabling remote operation of oscilloscopes. Variable resistor provides for adjustment of gain of amplifier, such that overall gain from input terminals of amplifier to output end of cable set to unity.

  17. Aspen Notebook: Cable and Continuing Education.

    Science.gov (United States)

    Adler, Richard; Baer, Walter S.

    This is the first of a planned series of Aspen Notebooks on cable television (CATV). Part I reports on research conducted by the Aspen Workshop on Uses of the Cable. It describes the status of continuing education and the history of educational television and explores the prospects created by cable's development for extending access to continuing…

  18. 47 CFR 32.2422 - Underground cable.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Underground cable. 32.2422 Section 32.2422... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2422 Underground cable. (a) This account shall include the original cost of underground cable installed in conduit and of...

  19. Cable Television Report and Suggested Ordinance.

    Science.gov (United States)

    League of California Cities, Sacramento.

    Guidelines and suggested ordinances for cable television regulation by local governments are comprehensively discussed in this report. The emphasis is placed on franchising the cable operator. Seventeen legal aspects of franchising are reviewed, and an exemplary ordinance is presented. In addition, current statistics about cable franchising in…

  20. Strain relief for power-cable connectors

    Science.gov (United States)

    Dean, W. T., III

    1980-01-01

    Easily fabricated grommet composed of polytetrafluoroethylene cylinder, containing U-shaped channels equally spaced around periphery, is used in power cable connectors to relieve strain on cables. Utilization of grommets provides more ease in cable insertion and removal. Potential applications include wiring in large residential and commercial buildings.

  1. Reducing Magnetic Fields Around Power Cables

    Science.gov (United States)

    Sargent, Noel B.; Gitelman, Florida; Pongracz-Bartha, Edward; Spalding, John

    1993-01-01

    Four power conductors arranged symmetrically about fifth grounded conductor. Four current-carrying wires arranged symmetrically around central grounded wire that nominally carries no current. In comparison with other cable configurations, this one results in smaller magnetic fields around cable. Technique for use when size of wires in cable makes twisting impractical.

  2. 30 CFR 18.45 - Cable reels.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Cable reels. 18.45 Section 18.45 Mineral... § 18.45 Cable reels. (a) A self-propelled machine, that receives electrical energy through a portable cable and is designed to travel at speeds exceeding 2.5 miles per hour, shall have a...

  3. 47 CFR 32.2421 - Aerial cable.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Aerial cable. 32.2421 Section 32.2421... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2421 Aerial cable. (a) This account shall include the original cost of aerial cable and of drop and block wires served by...

  4. 47 CFR 32.2423 - Buried cable.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Buried cable. 32.2423 Section 32.2423... FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2423 Buried cable. (a) This account shall include the original cost of buried cable as well as the cost of other material...

  5. 21 CFR 890.1175 - Electrode cable.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrode cable. 890.1175 Section 890.1175 Food... DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1175 Electrode cable. (a) Identification. An electrode cable is a device composed of strands of insulated electrical conductors...

  6. Power applications for superconducting cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Hansen, Steen; Jørgensen, Preben

    2000-01-01

    High temperature superconducting (HTS) cables for use in electric ac power systems are under development around the world today. There are two main constructions under development: the room temperature dielectric design and the cryogenic dielectric design. However, theoretical studies have shown...

  7. Educational Uses of Cable Television.

    Science.gov (United States)

    Cable Television Information Center, Washington, DC.

    The different educational uses of cable television as well as the methods and problems of that use are described in a state of the art review. The Federal Communications Commission regulations and related franchise activity are described, and the methods of using the educational channel as open or closed circuit TV or pay TV are indicated for…

  8. Cable Television: Developing Community Services.

    Science.gov (United States)

    Carpenter-Huffman, Polly; And Others

    The final volume of a four-volume study focuses on community use of cable television systems. Four separate aspects are discussed extensively: the possibilities of public access, use in municipal service applications, uses in education, and a guide for education planners. Each section contains several appendixes and the education sections include…

  9. Improving Energy Efficiency Cable Production

    Directory of Open Access Journals (Sweden)

    Iashutina Olga

    2016-01-01

    Full Text Available During the energy calculation is made at different temperatures of the heating surface. The influence of the speed of pulling on the cost of the finished products of cable products. The interrelation of speed broaching and temperature of the heating surface.

  10. temperature distribution in underground cable system

    Directory of Open Access Journals (Sweden)

    Rerak Monika

    2017-01-01

    Full Text Available The paper presents a mathematical model of heat transfer in the underground cable system. The computations were performed for flat formation of power cables buried in the ground at a depth of 2 meters. The model allows determining the two-dimensional temperature distribution in the soil, thermal backfill and power cables. The simulations studied the effect of soil thermal conductivity on the maximum temperature of the cable conductor. Furthermore, the effect of thermal backfill soil conductivity on the cable conductor temperature was studied. Numerical analyses were performed based on a program written in MATLAB.

  11. Offshore Cable Installation - Lillgrund. Lillgrund Pilot Project

    Energy Technology Data Exchange (ETDEWEB)

    Unosson, Oscar (Vattenfall Vindkraft AB, Stockholm (Sweden))

    2009-01-15

    This report describes the installation method and the experiences gained during the installation of the submarine cables for the offshore wind farm at Lillgrund. The wind farm consists of 48 wind turbines and is expected to produce 0.33 TWh annually. Different aspects of the installation, such as techniques, co-operation between the installation teams, weather conditions and regulatory and environmental issues are described in this report. In addition, recommendations and guidelines are provided, which hopefully can be utilised in future offshore wind projects. The trenches, in which the submarine cables were laid, were excavated weeks before the cable laying. This installation technique proved to be successful for the laying of the inter array cables. The export cable, however, was laid into position with difficulty. The main reason why the laying of the export cable proved more challenging was due to practical difficulties connected with the barge entrusted with the cable laying, Nautilus Maxi. The barge ran aground a number of times and it had difficulties with the thrusters, which made it impossible to manoeuvre. When laying the inter array cables, the method specification was closely followed, and the laying of the cables was executed successfully. The knowledge and experience gained from the offshore cable installation in Lillgrund is essential when writing technical specifications for new wind plant projects. It is recommended to avoid offshore cable installation work in winter seasons. That will lower the chances of dealing with bad weather and, in turn, will reduce the risks

  12. Cable Harness Assembly Planning in Virtual Environment

    Institute of Scientific and Technical Information of China (English)

    LIU Jianhua; NING Ruxin; BAI Shuqing; WANG Bile

    2006-01-01

    Based on the analysis of characteristic of cable harness planning in virtual environment, a discrete control node modeling (DCNM) method of cable harness in virtual environment and the cable harness assembly routing technique based on it are proposed. DCNM converts a cable harness into continuous flexed line segments connected by a series of section center points, and the design can realize cable harness planning through controlling those control nodes. This method of cable harness routing in the virtual environment breaks the status that virtual assembly process planning is just suitable for the rigid components at present, and impulse the virtual assembly process planning to be more practical. Relation algorithms have been verified in a self-developed system named virtual cable harness assembly planning (VCHAP) system, and this VCHAP system has been applied in assembly process planning of aerospace-related products.

  13. Power applications for superconducting cables in Denmark

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Østergaard, Jacob; Olsen, S. Krüger

    1999-01-01

    In Denmark a growing concern for environmental protection has lead to wishes that the open country is kept free of overhead lines as far as possible. New lines under 100 kV and existing 60/50 kV lines should be established as underground cables. Superconducting cables represent an interesting...... alternative to conventional cables, as they are able to transmit two or more times the energy than a conventional cable. HTS cables with a room temperature dielectric design are especially interesting as a target for replacing overhead lines. Superconducting cables in the overall network are of interest...... in cases such as transmission of energy into cities and through areas of special interest. The planned large groups of windmills in Denmark generating up to 2000 MVA or more both on dry land and off-shore will be an obvious case for the application of superconducting AC or DC cables. These opportunities...

  14. Self-healing cable apparatus and methods

    Science.gov (United States)

    Huston, Dryver (Inventor); Esser, Brian (Inventor)

    2007-01-01

    Self-healing cable apparatus and methods are disclosed. The cable has a central core surrounded by an adaptive cover that can extend over the entire length of the cable or just one or more portions of the cable. The adaptive cover includes a protective layer having an initial damage resistance, and a reactive layer. When the cable is subjected to a localized damaging force, the reactive layer responds by creating a corresponding localized self-healed region. The self-healed region provides the cable with enhanced damage resistance as compared to the cable's initial damage resistance. Embodiments of the invention utilize conventional epoxies or foaming materials in the reactive layer that are released to form the self-healed region when the damaging force reaches the reactive layer.

  15. Gjoea power cable; a green solution

    Energy Technology Data Exchange (ETDEWEB)

    Dretvik, Svein-Egil

    2010-07-01

    An alternative to today's power generation offshore using either gas or diesel, is alternating current (AC) electric power cable from shore. The power from shore through the AC cable gives high savings for the environment. The cable replaces 4 gas turbines with a total CO2 disposal of 240 00 tonnes each year which represents the disposal of 100 000 cars. ABB was awarded the contract which includes engineering, fabrication and installation of the power cable from Mongstad to the Gjoea platform which will be the longest AC cable in the world with a total length of 100 km. The presentation will include system design, qualification of dynamic power cable, cable fabrication experiences, testing at fabrication yard and installation aspects. (Author)

  16. High Voltage Cable Splicing and Cable Termination Techniques

    Science.gov (United States)

    1976-08-01

    solid dielectric insulations currently used are high-molecular-weight polyethylene (EP) and cross-linked poly- ethylene ( XLPE ). The EP insulation is...rated for 750 C a maximum temperature, and the XLPE insulation is rated for 900C maximum temperature. These insulation materials provide the conductor...The cost of installing PILC with copper conductors is compared to the cost of installing XLPE cable with aluminum conductors in Table 1. The

  17. Nonlinear Analysis of Cable Vibration of a Multispan Cable-Stayed Bridge under Transverse Excitation

    OpenAIRE

    Kun Lin; Dujian Zou; Minghai Wei

    2014-01-01

    The nonlinear vibrations of cable in a multispan cable-stayed bridge subjected to transverse excitation are investigated. The MECS (multielements cable system) model, where multielements per cable stay are used, is built up and used to analyze the model properties of the multispan cable-stayed bridges. Then, a simplified two-degrees-of-freedom (2-DOFs) model, where the tower or the deck is reduced to a beam, is proposed to analyze the nonlinear dynamic behaviors of the beam and cable. The res...

  18. Electromagnetic Transients in Power Cables

    DEFF Research Database (Denmark)

    Silva, Filipe Faria Da; Bak, Claus Leth

    of electromagnetic phenomena associated to their operation, among them electromagnetic transients, increased as well. Transient phenomena have been studied since the beginning of power systems, at first using only analytical approaches, which limited studies to more basic phenomena; but as computational tools became...... concerning HVAC cables. An important topic that is not covered in this book is measurements protocols/ methods. The protocols used when performing measurements on a cable depend on what is to be measured, the available equipment and accessibility. Readers interested in the topic are referred to search....... The chapter ends by proposing a systematic method that can be used when doing the insulation co-ordination study for a line, as well as the modelling requirements, both modelling depth and modelling detail of the equipment, for the study of the different types of transients followed by a step-by-step generic...

  19. Condition Monitoring of Power Cables

    OpenAIRE

    Lewin, P L; L. Hao; Swaffield, D J; Swingler, S.G.

    2007-01-01

    A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable systems. A method that only uses passive components at the measuring points has been developed and is outlined in this paper. More recent work, funded through the EPSRC Supergen V, UK Energy Infrastructure (AMPerES) grant in collaboration with UK ...

  20. Low Friction Cryostat for HTS Power Cable of Dutch Project

    NARCIS (Netherlands)

    Chevtchenko, O.; Zuijderduin, R.; Smit, J.; Willen, D.; Lentge, H.; Thidemann, C.; Traeholt, C.

    2012-01-01

    Particulars of 6 km long HTS AC power cable for Amsterdam project are: a cable has to fit in an annulus of 160 mm, with only two cooling stations at the cable ends [1]. Application of existing solutions for HTS cables would result in excessively high coolant pressure drop in the cable, possibly affe

  1. Broadband description of the copper cable transfer function

    NARCIS (Netherlands)

    Waal, D.C.H.

    2007-01-01

    This report is describes the characteristics of two different copper cables, namely the coax cable and the twisted pair cable. By using the Maxwell equations we can describe the coax cable and the twisted pair cable with the Bessel functions. By these Bessel functions we can simulate the two seconda

  2. 30 CFR 75.603 - Temporary splice of trailing cable.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Temporary splice of trailing cable. 75.603... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.603 Temporary splice of trailing cable. One temporary splice may be made in any trailing cable. Such trailing cable...

  3. Field application of a cable NDT system for cable-stayed bridge using MFL sensors integrated

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Won; Choi, Jun Sung; Park, Seung Hee [Sungkyunkwan University, Seoul (Korea, Republic of); Lee, Eun Chan [Korea Maintance Co., Ltd., Seoul (Korea, Republic of)

    2014-02-15

    In this study, an automated cable non-destructive testing(NDT) system was developed to monitor the steel cables that are a core component of cable-stayed bridges. The magnetic flux leakage(MFL) method, which is suitable for ferromagnetic continuum structures and has been verified in previous studies, was applied to the cable inspection. A multi-channel MFL sensor head was fabricated using hall sensors and permanent magnets. A wheel-based cable climbing robot was fabricated to improve the accessibility to the cables, and operating software was developed to monitor the MFL-based NDT research and control the climbing robot. Remote data transmission and robot control were realized by applying wireless LAN communication. Finally, the developed element techniques were integrated into an MFL-based cable NDT system, and the field applicability of this system was verified through a field test at Seohae Bridge, which is a typical cable-stayed bridge currently in operation.

  4. Research on Construction Monitoring Techniques for Cable Replacement of the Cable-Stayed Bridge

    Directory of Open Access Journals (Sweden)

    Dai Pu

    2013-09-01

    Full Text Available Due to various reasons, some cable-stayed bridges require the replacement of part or all stay cables after operating for a period of time. In this study, based on some engineering practices of stay cable replacement, the condition of bridge structure before replacement is analyzed with Finite Element Analysis method for plane member system. The theoretical calculations, cable force measurement, replacement methods and process monitoring for cable replacement are introduced to find out the key technical problems. From the specified bridge monitoring practices, we suggest monitoring cable tension and the main beam alignment during the process of cable replacement, to make sure the cable-stayed bridge reaches its design conditions.

  5. Analytical and numerical construction of equivalent cables.

    Science.gov (United States)

    Lindsay, K A; Rosenberg, J R; Tucker, G

    2003-08-01

    The mathematical complexity experienced when applying cable theory to arbitrarily branched dendrites has lead to the development of a simple representation of any branched dendrite called the equivalent cable. The equivalent cable is an unbranched model of a dendrite and a one-to-one mapping of potentials and currents on the branched model to those on the unbranched model, and vice versa. The piecewise uniform cable, with a symmetrised tri-diagonal system matrix, is shown to represent the canonical form for an equivalent cable. Through a novel application of the Laplace transform it is demonstrated that an arbitrary branched model of a dendrite can be transformed to the canonical form of an equivalent cable. The characteristic properties of the equivalent cable are extracted from the matrix for the transformed branched model. The one-to-one mapping follows automatically from the construction of the equivalent cable. The equivalent cable is used to provide a new procedure for characterising the location of synaptic contacts on spinal interneurons.

  6. How do you like them cables?

    CERN Multimedia

    Sergei Malyukov

    Cabling work is not for clautrophobic people! Cables are like the blood vessels and nervous system of ATLAS. With the help of all these cables, we can power ATLAS, control the detector and read out the data. Like the human blood vessels, they penetrate inside the ATLAS volume, reaching each of its elements. The ATLAS developers started to think about design of services, cables and pipes at the very first stages of the project. The cabling project has been developing most intensively during the last five years, passing through the projection and CAD design phases, then the installation of cable trays and finally the cables. The cable installation itself took two and a half years and was done by teams of technicians from several institutes from Russia, the Czech Republic and Poland. Here are some numbers to illustrate the scale of the ATLAS cabling system. More than 25000 optical fiber channels are used for reading the information from the sub-detectors and delivering the timing signals. The total numbe...

  7. Nonlinear Finite Element Analysis of Ocean Cables

    Institute of Scientific and Technical Information of China (English)

    Nam-Il KIM; Sang-Soo JEON; Moon-Young KIM

    2004-01-01

    This study has focused on developing numerical procedures for the dynamic nonlinear analysis of cable structures subjected to wave forces and ground motions in the ocean. A geometrically nonlinear finite element procedure using the isoparametric curved cable element based on the Lagrangian formulation is briefly summarized. A simple and accurate method to determine the initial equilibrium state of cable systems associated with self-weights, buoyancy and the motion of end points is presented using the load incremental method combined with penalty method. Also the Newmark method is used for dynamic nonlinear analysis of ocean cables. Numerical examples are presented to validate the present numerical method.

  8. Braided tubular superelastic cables provide improved spinal stability compared to multifilament sublaminar cables.

    Science.gov (United States)

    Tremblay, Jaëlle; Mac-Thiong, Jean-Marc; Brailovski, Vladimir; Petit, Yvan

    2015-09-01

    This study investigates the use of braided tubular superelastic cables, previously used for sternum closure following sternotomy, as sublaminar fixation method. It compares the biomechanical performance of spinal instrumentation fixation systems with regular sublaminar cables and proprietary superelastic cables. A hybrid experimental protocol was applied to six porcine L1-L4 spinal segments to compare multifilament sublaminar cables (Atlas, Medtronic Sofamor Danek, Memphis, TN) with proprietary superelastic cables. First, intact total range of motion was determined for all specimens using pure moment loading. Second, pure moments were imposed to the instrumented specimens until these intact total ranges of motion were reproduced. Compared to the intact specimens, the use of superelastic cables resulted in stiffer instrumented specimens than the use of multifilament cables for all the loading modes except axial torsion. Consequently, the superelastic cables limited the instrumented segments mobility more than the multifilament cables. Spinal instrumentation fixation systems using superelastic cables could be a good alternative to conventional sublaminar cables as it maintains a constant stabilization of the spine during loading.

  9. Nonlinear Analysis of Cable Vibration of a Multispan Cable-Stayed Bridge under Transverse Excitation

    Directory of Open Access Journals (Sweden)

    Kun Lin

    2014-01-01

    Full Text Available The nonlinear vibrations of cable in a multispan cable-stayed bridge subjected to transverse excitation are investigated. The MECS (multielements cable system model, where multielements per cable stay are used, is built up and used to analyze the model properties of the multispan cable-stayed bridges. Then, a simplified two-degrees-of-freedom (2-DOFs model, where the tower or the deck is reduced to a beam, is proposed to analyze the nonlinear dynamic behaviors of the beam and cable. The results of MECS model analysis show that the main tower in the multispan cable-stayed bridge is prone to the transverse vibration, and the local vibration of cables only has a little impact on the frequency values of the global modes. The results of simplified model analysis show that the energy can be transformed between the modes of the beam and cable when the nature frequencies of them are very close. On the other hand, with the transverse excitation changing, the cable can exhibit richer quasi-periodic or chaotic motions due to the nonlinear terms caused by the coupled mode between the beam and cable.

  10. A New Multiconstraint Method for Determining the Optimal Cable Stresses in Cable-Stayed Bridges

    Directory of Open Access Journals (Sweden)

    B. Asgari

    2014-01-01

    Full Text Available Cable-stayed bridges are one of the most popular types of long-span bridges. The structural behaviour of cable-stayed bridges is sensitive to the load distribution between the girder, pylons, and cables. The determination of pretensioning cable stresses is critical in the cable-stayed bridge design procedure. By finding the optimum stresses in cables, the load and moment distribution of the bridge can be improved. In recent years, different research works have studied iterative and modern methods to find optimum stresses of cables. However, most of the proposed methods have limitations in optimising the structural performance of cable-stayed bridges. This paper presents a multiconstraint optimisation method to specify the optimum cable forces in cable-stayed bridges. The proposed optimisation method produces less bending moments and stresses in the bridge members and requires shorter simulation time than other proposed methods. The results of comparative study show that the proposed method is more successful in restricting the deck and pylon displacements and providing uniform deck moment distribution than unit load method (ULM. The final design of cable-stayed bridges can be optimised considerably through proposed multiconstraint optimisation method.

  11. A new multiconstraint method for determining the optimal cable stresses in cable-stayed bridges.

    Science.gov (United States)

    Asgari, B; Osman, S A; Adnan, A

    2014-01-01

    Cable-stayed bridges are one of the most popular types of long-span bridges. The structural behaviour of cable-stayed bridges is sensitive to the load distribution between the girder, pylons, and cables. The determination of pretensioning cable stresses is critical in the cable-stayed bridge design procedure. By finding the optimum stresses in cables, the load and moment distribution of the bridge can be improved. In recent years, different research works have studied iterative and modern methods to find optimum stresses of cables. However, most of the proposed methods have limitations in optimising the structural performance of cable-stayed bridges. This paper presents a multiconstraint optimisation method to specify the optimum cable forces in cable-stayed bridges. The proposed optimisation method produces less bending moments and stresses in the bridge members and requires shorter simulation time than other proposed methods. The results of comparative study show that the proposed method is more successful in restricting the deck and pylon displacements and providing uniform deck moment distribution than unit load method (ULM). The final design of cable-stayed bridges can be optimised considerably through proposed multiconstraint optimisation method.

  12. Pay Cable: A Viable Advertising Medium?

    Science.gov (United States)

    Krugman, Dean M.; Barban, Arnold M.

    Cable television, which cannot only clarify local signals to weak signal areas but can also bring in distant signals to areas which have been receiving few signals, has the capacity to present special television programs to customers for extra fees. The number of pay cable subscribers is growing and industry projections are that it will reach 20…

  13. Cable Television in the Classroom. ERIC Digest.

    Science.gov (United States)

    Holmes, Glen A.; Branch, Robert C.

    Using cable television in the classroom allows teachers to include the latest news and current events in class discussions. However, many educational practitioners are uninformed about the concept and lack the knowledge to implement the technology in the classroom. This digest describes how cable television can be integrated into elementary and…

  14. Crossed Wires; Cable Television in New Jersey.

    Science.gov (United States)

    Center for Analysis of Public Issues, Princeton, NJ.

    Cable television (CATV) in New Jersey has been almost nonexistent: Because of the state's proximity to the major cities of New York and Philadelphia, there has been a scarcity of New Jersey-oriented news and public affairs programing. Cable television access, it is suggested, could fill this information gap in New Jersey if the state government…

  15. Cable Television: Its Urban Context and Programming.

    Science.gov (United States)

    Warthman, Forrest

    Cable television's future in urban settings is discussed in the context of alternative media capable of serving similar markets with similar programing. In addition to cable television, other transmission networks such as the telephone network, radio and television broadcasting, microwave networks, domestic satellites, and recording media are…

  16. Calorimetric measurements of losses in HTS cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Veje, Niels Erling Winsløv; Rasmussen, Carsten

    2001-01-01

    A calorimetric test rig is used to investigate various loss components in a 10 m long superconducting cable model. A calorimetric technique, based on thermocouple measurements, is used to measure the losses of the 10 m long superconducting cable model. The current dependent losses are also measured...

  17. Cable Television: The Process of Franchising.

    Science.gov (United States)

    Johnson, Leland L.; Botein, Michael

    In an effort to insure that cable television franchising procedures at the local level are based on a competitive and well-conceived selection process, this report discusses some of the most important steps of the franchising process. Not only does it show how the community should assess its needs and appraise the merits of the cable operator, but…

  18. Assessment of sodium conductor distribution cable

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    The study assesses the barriers and incentives for using sodium conductor distribution cable. The assessment considers environmental, safety, energy conservation, electrical performance and economic factors. Along with all of these factors considered in the assessment, the sodium distribution cable system is compared to the present day alternative - an aluminum conductor system. (TFD)

  19. Community Cable Television--Hungarian Perspectives.

    Science.gov (United States)

    Szekfu, Andras

    This paper argues that, although community cable television is one of the most dynamic (although experimental) elements of the Hungarian media structure, it is well on its way toward institutionalization. It is suggested that whether community cable television is able to retain the spontaneity, innovativeness, and elasticity of its early days may…

  20. 76 FR 32866 - Cable Landing Licenses; Correction

    Science.gov (United States)

    2011-06-07

    ... Systems Agency in the regulations that we published in the Federal Register of January 14, 2002, 67 FR... COMMISSION 47 CFR Part 1 Cable Landing Licenses; Correction AGENCY: Federal Communications Commission. ACTION... streamlined processing of cable landing license applications. Need for Correction As published, the...

  1. First Russian long length HTS power cable

    Science.gov (United States)

    Volkov, Eduard P.; Vysotsky, Vitaly S.; Firsov, Valery P.

    2012-11-01

    The Russian R&D Program for superconducting power devices is underway, supported both by government and electric power companies. In this program R&D on HTS power cables is considered as most advanced and close to commercialization. In the framework of the program, several, heavily instrumented, 5 m cables have been tested following by the 30 m - 3 phase experimental power cable development and testing in 2008-2009. The latest achievement is development and testing of the first long length 3 × 200 m power cable with rating 1.5/2 kA-20 kV. In parallel with just the cable development the innovative cryogenic system has been developed as well for the cable cooling. The system is using neon as working substance and radial turbo-machines in refrigerator. Cooling power is up to ∼8 kW at 65 K, inter-maintenance time ∼30,000 h. The cryogenic pump with superconducting motor can be used to provide subcooled liquid nitrogen flow ∼0.1-1.5 kg/s at 0.1-2.5 MPa pressure. After extensive tests at special test facility, HTS power cable and cryogenic system are planning to be installed at some substation in Moscow utility grid. In this review some details about Russian HTS power application program, 200 m cable and cryogenic system designs and tests results are presented.

  2. The Selling of Cable Television 1972.

    Science.gov (United States)

    National Cable Television Association, Inc., Washington, DC.

    The 1972 Cable Television Marketing Workshop reviewed in depth a wide variety of marketing and public relations techniques as they pertain to cable television. The workshop was attended by representatives of commercial television systems throughout the United States; it was intended to disseminate the sales and marketing experience of those…

  3. Joystick With Cable Springs Offers Better Feel

    Science.gov (United States)

    Kerley, James; Ecklund, Wayne

    1992-01-01

    Improved joystick allows motion in 6 degrees of freedom, biased toward central position and orientation by 16 segments of cable serving as springs. Improvement in feel and control results from nonlinear compliance of cable-spring assembly. Nonlinear variations accommodate natural reactions of hand and brain. Operator functions as part of feedback control loop. More comfortable, increases ability to exert control and reduces fatigue.

  4. Parallel monostrand stay cable bending fatigue

    DEFF Research Database (Denmark)

    Winkler, Jan Pawel

    of damage and replacement of bridge stay cables due to wind and traffic-induced fatigue. The understanding of fatigue mechanisms in most steel structures is well established. However, in the case of cables composed of steel strands, many important aspects related with bending fatigue remain to be clarified......This dissertation investigates the bending fatigue response of high-strength steel monostrands and multistrand stay cables to cyclic transverse deformations. Increasing bridge stock numbers and a push for longer cable-supported span lengths have led to an increased number of reported incidents...... associated with variable loading, and different testing procedures. As most of the contemporary stay cables are comprised of a number of individual highstrength steel monostrands, the research study started with an extensive experimental work on the fatigue response of a single monostrand to cyclic flexural...

  5. Nuclear power plant cable materials :

    Energy Technology Data Exchange (ETDEWEB)

    Celina, Mathias C.; Gillen, Kenneth T; Lindgren, Eric Richard

    2013-05-01

    A selective literature review was conducted to assess whether currently available accelerated aging and original qualification data could be used to establish operational margins for the continued use of cable insulation and jacketing materials in nuclear power plant environments. The materials are subject to chemical and physical degradation under extended radiationthermal- oxidative conditions. Of particular interest were the circumstances under which existing aging data could be used to predict whether aged materials should pass loss of coolant accident (LOCA) performance requirements. Original LOCA qualification testing usually involved accelerated aging simulations of the 40-year expected ambient aging conditions followed by a LOCA simulation. The accelerated aging simulations were conducted under rapid accelerated aging conditions that did not account for many of the known limitations in accelerated polymer aging and therefore did not correctly simulate actual aging conditions. These highly accelerated aging conditions resulted in insulation materials with mostly inert aging processes as well as jacket materials where oxidative damage dropped quickly away from the air-exposed outside jacket surface. Therefore, for most LOCA performance predictions, testing appears to have relied upon heterogeneous aging behavior with oxidation often limited to the exterior of the cable cross-section a situation which is not comparable with the nearly homogenous oxidative aging that will occur over decades under low dose rate and low temperature plant conditions. The historical aging conditions are therefore insufficient to determine with reasonable confidence the remaining operational margins for these materials. This does not necessarily imply that the existing 40-year-old materials would fail if LOCA conditions occurred, but rather that unambiguous statements about the current aging state and anticipated LOCA performance cannot be provided based on

  6. Simulation of the cabling process for Rutherford cables: An advanced finite element model

    Science.gov (United States)

    Cabanes, J.; Garlasche, M.; Bordini, B.; Dallocchio, A.

    2016-12-01

    In all existing large particle accelerators (Tevatron, HERA, RHIC, LHC) the main superconducting magnets are based on Rutherford cables, which are characterized by having: strands fully transposed with respect to the magnetic field, a significant compaction that assures a large engineering critical current density and a geometry that allows efficient winding of the coils. The Nb3Sn magnets developed in the framework of the HL-LHC project for improving the luminosity of the Large Hadron Collider (LHC) are also based on Rutherford cables. Due to the characteristics of Nb3Sn wires, the cabling process has become a crucial step in the magnet manufacturing. During cabling the wires experience large plastic deformations that strongly modify the geometrical dimensions of the sub-elements constituting the superconducting strand. These deformations are particularly severe on the cable edges and can result in a significant reduction of the cable critical current as well as of the Residual Resistivity Ratio (RRR) of the stabilizing copper. In order to understand the main parameters that rule the cabling process and their impact on the cable performance, CERN has developed a 3D Finite Element (FE) model based on the LS-Dyna® software that simulates the whole cabling process. In the paper the model is presented together with a comparison between experimental and numerical results for a copper cable produced at CERN.

  7. Self-healing cable for extreme environments

    Science.gov (United States)

    Huston, Dryver R. (Inventor); Tolmie, Bernard R. (Inventor)

    2009-01-01

    Self-healing cable apparatus and methods disclosed. The self-healing cable has a central core surrounded by an adaptive cover that can extend over the entire length of the self-healing cable or just one or more portions of the self-healing cable. The adaptive cover includes an axially and/or radially compressible-expandable (C/E) foam layer that maintains its properties over a wide range of environmental conditions. A tape layer surrounds the C/E layer and is applied so that it surrounds and axially and/or radially compresses the C/E layer. When the self-healing cable is subjected to a damaging force that causes a breach in the outer jacket and the tape layer, the corresponding localized axially and/or radially compressed portion of the C/E foam layer expands into the breach to form a corresponding localized self-healed region. The self-healing cable is manufacturable with present-day commercial self-healing cable manufacturing tools.

  8. 46 CFR 111.60-4 - Minimum cable conductor size.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4...-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-4 Minimum cable conductor size. Each cable conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must...

  9. Non-linear stochastic response of a shallow cable

    DEFF Research Database (Denmark)

    Larsen, Jesper Winther; Nielsen, Søren R.K.

    2004-01-01

    The paper considers the stochastic response of geometrical non-linear shallow cables. Large rain-wind induced cable oscillations with non-linear interactions have been observed in many large cable stayed bridges during the last decades. The response of the cable is investigated for a reduced two-degrees-of-freedom...

  10. 30 CFR 77.606 - Energized trailing cables; handling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Energized trailing cables; handling. 77.606... COAL MINES Trailing Cables § 77.606 Energized trailing cables; handling. Energized medium- and high-voltage trailing cables shall be handled only by persons wearing protective rubber gloves (see § 77.606-1...

  11. 47 CFR 76.614 - Cable television system regular monitoring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television system regular monitoring. 76.614 Section 76.614 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76.614 Cable television system regular monitoring. Cable television...

  12. 47 CFR 76.612 - Cable television frequency separation standards.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television frequency separation standards. 76.612 Section 76.612 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Technical Standards § 76.612 Cable television frequency separation standards. All cable...

  13. 47 CFR 76.403 - Cable television system reports.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television system reports. 76.403 Section 76.403 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Forms and Reports § 76.403 Cable television system reports. The operator of every operational cable...

  14. 30 CFR 75.828 - Trailing cable pulling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cable pulling. 75.828 Section 75.828... Longwalls § 75.828 Trailing cable pulling. The trailing cable must be de-energized prior to being pulled by any equipment other than the continuous mining machine. The cable manufacturer's recommended...

  15. 47 CFR 32.2426 - Intrabuilding network cable.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Intrabuilding network cable. 32.2426 Section 32... Intrabuilding network cable. (a) This account shall include the original cost of cables and wires located on the... between buildings on one customer's same premises. Intrabuilding network cables are used to...

  16. 47 CFR 32.2424 - Submarine & deep sea cable.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Submarine & deep sea cable. 32.2424 Section 32... Submarine & deep sea cable. (a) This account shall include the original cost of submarine cable and deep sea... defined below, are to be maintained for nonmetallic submarine and deep sea cable and metallic...

  17. Bending behavior of lapped plastic ehv cables

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, G H; Muller, A C

    1980-01-01

    One of the factors delaying the development of lapped polymeric cables has been their reputed poor bending characteristics. Complementary programs were begun at BNL several years ago to mathematically model the bending of synthetic tape cables and to develop novel plastic tapes designed to have moduli more favorable to bending. A series of bend tests was recently completed to evaluate the bending performance of several tapes developed for use in experimental superconducting cables. The program is discussed and the results of the bend tests are summarized.

  18. Frequency Dependent Losses in Transmission Cable Conductors

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt; Holbøll, Joachim; Guðmundsdóttir, Unnur Stella

    2011-01-01

    , such as thermal conditions in and around the cable, as well as the heat generated in conductors, screens, armours etc., taking into account proximity and skin effects. The work performed and presented in this paper is concerned with an improved determination of the losses generated in the conductor, by means...... of better calculation of the AC resistance of transmission cable conductors, in particular regarding higher frequencies. In this way, also losses under harmonics can be covered. Furthermore, the model is suitable for modelling of transient attenuation in high voltage cables. The AC resistance is calculated...

  19. DC Characterization of the Coaxial Superconducting Cable

    Science.gov (United States)

    Šouc, J.; Gömöry, F.; Vojenčiak, M.; Frolek, L.; Isfort, D.; Ehrenberg, J.; Bock, J.

    2008-01-01

    Coaxial cable model with superconducting core and superconducting shield conductor was constructed and tested in DC regime. While the core was already examined in our previous works, in this contribution the detailed study of the superconducting shield conductor in DC conditions is presented. It consists of 16 ReBCO coated tapes with critical current 35 A each connected in parallel. Using shunts with known values placed in series the currents in individual tapes were possible to measure. Distribution of the total cable current into the individual tapes was monitored and its influence on critical current of the cable is discussed.

  20. Optimizing of the cable bedding and the ampacity of underground power cables in trefoil formation by using the gravitational search algorithm

    National Research Council Canada - National Science Library

    Perovic, Bojan; Klimenta, Dardan; Radosavljevic, Jordan; Jevtic, Miroljub

    2016-01-01

    This paper considers the problem of the determination of the optimum values for dimensions of cable trench and cable bedding, interaxial spacings between power cables in trefoil formation and cable ampacities...

  1. Understanding losses in three core armoured submarine cables

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Ebdrup, Thomas; Bak, Claus Leth

    2016-01-01

    . For practical an economical reasons the preferred choice of cable for both the array and the transmission cables are three-core armoured submarine cables. Therefore, it has becoming increasingly important to be able to calculate the ampacity of such cables accurately. At present time, the ampacity of three......-core armoured submarine cables is calculated according to IEC 60287-1-1 [1]. Various measurements conducted both by cable manufacturers and transmission system operators (TSO) have shown that using the cable rating method stated in IEC 60287-1-1 underestimates the cable ampacity [2]-[6]. Furthermore....... However, research performed in this paper shows that while the armour is responsible for the extra losses, the main calculation error for typical HVAC submarine cables may be in the screen’s loss factor (λ1). Overestimation of the cable losses may result in core cross-sections too large with more material...

  2. Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator

    OpenAIRE

    Moses, Matthew S.; Murphy, Ryan J.; Kutzer, Michael D. M.; Armand, Mehran

    2015-01-01

    This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. Howev...

  3. Application Designs of Cable Modem System%Cable Modem系统应用设计

    Institute of Scientific and Technical Information of China (English)

    占亿民; 潘永跃; 王晖; 夏卉

    2002-01-01

    本文总结了Cable Modem系统的原理和CMTS的关键功能,系统介绍了南京电视台Cable Modem系统的设计思路和设计方法.采用源IP地址路由技术实现了用户子网划分和区分服务,并且支持基于Cable Modem系统的专网接入业务.

  4. Simplified modeling of EM field coupling to complex cable bundles

    OpenAIRE

    Schetelig, B.; J. Keghie; Kanyou Nana, R.; Fichte, L.-O.; S. Potthast; Dickmann, S.

    2010-01-01

    In this contribution, the procedure "Equivalent Cable Bundle Method" is used for the simplification of large cable bundles, and it is extended to the application on differential signal lines. The main focus is on the reduction of twisted-pair cables. Furthermore, the process presented here allows to take into account cables with wires that are situated quite close to each other. The procedure is based on a new approach to calculate the geometry of the simplified cable and us...

  5. Parametrically excited oscillation of stay cable and its control in cable-stayed bridges

    Institute of Scientific and Technical Information of China (English)

    孙炳楠; 汪至刚; 高赞明; 倪一清

    2003-01-01

    This paper presents a nonlinear dynamic model for simulation and analysis of a kind of parametrically excited vibration of stay cable caused by support motion in cable-stayed bridges. The sag, inclination angle of the stay cable are considered in the model, based on which, the oscillation mechanism and dynamic response characteristics of this kind of vibration are analyzed through numerical calculation. It is noted that parametrically excited oscillation of a stay cable with certain sag, inclination angle and initial static tension force may occur in cable-stayed bridges due to deck vibration under the condition that the natural frequency of a cable approaches to about half of the first model frequency of the bridge deck system. A new vibration control system installed on the cable anchorage is proposed as a possible damping system to suppress the cable parametric oscillation. The numerical calculation results showed that with the use of this damping system, the cable oscillation due to the vibration of the deck and/or towers will be considerably reduced.

  6. Parametrically excited oscillation of stay cable and its control in cable-stayed bridges"

    Institute of Scientific and Technical Information of China (English)

    孙炳楠; 汪至刚; 高赞明; 倪一清

    2003-01-01

    This paper presents a nonlinear dynamic model for simulation and analysis of a kind of parametrically excited vibration of stay cable caused by support motion in cable-stayed bridges. The sag, inclination angle of the stay cable are considered in the model, based on which, the oscillation mechanism and dynamic response characteristics of this kind of vibration are analyzed through numerical calculation. It is noted that parametrically excited oscillation of a stay cable with certain sag, inclination angle and initial static tension force may occur in cable-stayed bridges due to deck vibration under the condition that the natural frequency of a cable approaches to about half of the first model frequency of the bridge deck system. A new vibration control system installed on the cable anchorage is proposed as a possible damping system to suppress the cable parametric oscillation. The numerical calculation results showed that with the use of this damping system, the cable oscillation due to the vibration of the deck and/or towers will be considerably reduced.

  7. Switching Restrikes in HVAC Cable Lines and Hybrid HVAC Cable/OHL Lines

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Bak, Claus Leth; Balle Holst, Per

    2011-01-01

    The disconnection of HV underground cables may, if unsuccessful, originate a restrike in the circuit breaker, leading to high overvoltages, and potentially damaging the cable and near equipment. Due to the cable high capacitance and low resistance the voltage damping is slow, resulting, half...... a cycle after the disconnection, in a voltage of approximately 2 pu at the circuit breaker terminals. In case of restrike in that instant, it is theoretical possible to attain an overvoltage of 3 pu. The overvoltage can be even larger in hybrid cable-Overhead Lines (OHL), due to voltage magnifications...

  8. Condition Monitoring of Cables Task 3 Report: Condition Monitoring Techniques for Electric Cables

    Energy Technology Data Exchange (ETDEWEB)

    Villaran, M.; Lofaro, R.; na

    2009-11-30

    For more than 20 years the NRC has sponsored research studying electric cable aging degradation, condition monitoring, and environmental qualification testing practices for electric cables used in nuclear power plants. This report summarizes several of the most effective and commonly used condition monitoring techniques available to detect damage and measure the extent of degradation in electric cable insulation. The technical basis for each technique is summarized, along with its application, trendability of test data, ease of performing the technique, advantages and limitations, and the usefulness of the test results to characterize and assess the condition of electric cables.

  9. Chinese Market for Fibres and Cables

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    This article presents a summary of Chinese market of optical fibres and cables based on the development of the optical communications industry. Analysis shows that the market will keep growing for sometime in the future.

  10. Frequency Dependent Losses in Transmission Cable Conductors

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt; Holbøll, Joachim; Guðmundsdóttir, Unnur Stella

    2011-01-01

    Denmark is taking on the exciting project of undergrounding the electricity transmission grid. In 2009 it was decided by the Danish government to underground large parts of the 400 kV and the entire 132-150 kV transmission network before the end of 2030. For ensuring network stability...... and economical gain, such severe network changes necessitate correct estimation and optimisation of load conditions in the cable grid. Both IEC and IEEE have published standards for rating transmission cables' current carrying capacity. These standards are based on assumptions of a number of parameters...... of better calculation of the AC resistance of transmission cable conductors, in particular regarding higher frequencies. In this way, also losses under harmonics can be covered. Furthermore, the model is suitable for modelling of transient attenuation in high voltage cables. The AC resistance is calculated...

  11. Insulation Degradation Diagnostic Technology to XLPE Cable

    Science.gov (United States)

    Uchida, Katsumi; Okamoto, Tatsuki

    XLPE power cables have been in use for long time now and some of them are approaching 30 years of their designed lifetime. However, under the present severe economic situation, it is necessary to use the existing apparatus as long as possible. So, degradation diagnostic methods with high reliability are needed earnestly. This paper explains the insulation degradation mechanism of XLPE power cables and the newest diagnostic methods on each voltage class. In 3.3-77kV classes, fairly high extents of the cable accidents depend on the water-tree degradation. For 3.3-6.6kV class cables, on-line diagnostic methods with high reliability to detect bridged water-trees have been developed and put in practical use. And, for 22-77kV classes, two promising off-line diagnostic methods to detect un-bridged water-trees have begun to carry out in on-site tests.

  12. Practical Damping Identification of FAST Cable Suspension

    Directory of Open Access Journals (Sweden)

    Jinghai Sun

    2014-03-01

    Full Text Available FAST focus cabin is suspended and driven by 6 parallel large span cables. Low stiffness of cables makes the cabin sensitive to disturbance and difficult to control. Structural damping then becomes a key factor that can improve control ability. Therefore, a reasonable damping estimation is important for system design. In this paper, a practical damping identification method is developed based on Ibrahim-time-domain algorithm. The method shows satisfied performance on accuracy and reliability in simulation test and is utilized in vibration experiments to identify damping ratios of both single cable model and FAST 3 m scale cable suspension model. Finally, a preliminary analysis of the damping properties is given out based on the results of identification.

  13. A small cable tunnel inspection robot design

    Science.gov (United States)

    Zhou, Xiaolong; Guo, Xiaoxue; Huang, Jiangcheng; Xiao, Jie

    2017-04-01

    Modern city mainly rely on internal electricity cable tunnel, this can reduce the influence of high voltage over-head lines of urban city appearance and function. In order to reduce the dangers of cable tunnel artificial inspection and high labor intensity, we design a small caterpillar chassis in combination with two degrees of freedom robot with two degrees of freedom camera pan and tilt, used in the cable tunnel inspection work. Caterpillar chassis adopts simple return roller, damping structure. Mechanical arm with three parallel shafts, finish the up and down and rotated action. Two degrees of freedom camera pan and tilt are used to monitor cable tunnel with 360 °no dead angle. It looks simple, practical and efficient.

  14. Ecology: Electrical Cable Bacteria Save Marine Life.

    Science.gov (United States)

    Nielsen, Lars Peter

    2016-01-11

    Animals at the bottom of the sea survive oxygen depletion surprisingly often, and a new study identifies cable bacteria in the sediment as the saviors. The bacterial electrical activity creates an iron 'carpet', trapping toxic hydrogen sulfide.

  15. Improved ferrous shielding for flat cables

    Science.gov (United States)

    Drechsler, R. J.

    1969-01-01

    To improve shielding of flat multicore cables, a thin, seamless ferrous shield around all cores optimizes low frequency magnetic shielding. Such shielding is covered with an ultrathin seamless coat of highly conductive nonferrous material.

  16. Carbon Fiber Reinforced Polymer for Cable Structures—A Review

    Directory of Open Access Journals (Sweden)

    Yue Liu

    2015-10-01

    Full Text Available Carbon Fiber Reinforced Polymer (CFRP is an advanced composite material with the advantages of high strength, lightweight, no corrosion and excellent fatigue resistance. Therefore, unidirectional CFRP has great potential for cables and to replace steel cables in cable structures. However, CFRP is a typical orthotropic material and its strength and modulus perpendicular to the fiber direction are much lower than those in the fiber direction, which brings a challenge for anchoring CFRP cables. This paper presents an overview of application of CFRP cables in cable structures, including historical review, state of the art and prospects for the future. After introducing properties of carbon fibers, mechanical characteristics and structural forms of CFRP cables, existing CFRP cable structures in the world (all of them are cable bridges are reviewed. Especially, their CFRP cable anchorages are presented in detail. New applications for CFRP cables, i.e., cable roofs and cable facades, are also presented, including the introduction of a prototype CFRP cable roof and the conceptual design of a novel structure—CFRP Continuous Band Winding System. In addition, other challenges that impede widespread application of CFRP cable structures are briefly introduced.

  17. Bias in Cable News: Persuasion and Polarization

    OpenAIRE

    Martin, Gregory J.; Ali Yurukoglu

    2014-01-01

    We measure the persuasive effects of slanted news and tastes for like-minded news, exploiting cable channel positions as exogenous shifters of cable news viewership. Channel positions do not correlate with demographics that predict viewership and voting, nor with local satellite viewership. We estimate that Fox News increases Republican vote shares by 0.3 points among viewers induced into watching 2.5 additional minutes per week by variation in position. We then estimate a model of voters who...

  18. Monopoly quality degradation in cable television

    OpenAIRE

    Crawford, Gregory S; Shum, Matthew

    2003-01-01

    Using an empirical framework derived from models of nonlinear pricing, we estimate the degree of quality degradation in cable television markets. We find lower bounds on quality degradation ranging from 11% to 45% of observed service qualities. Furthermore, cable operators in markets with local regulatory oversight tend to offer significantly higher quality products, and engage in less quality degradation. While prices are also higher in markets with local regulatory oversight, we find that c...

  19. Analysis of Surveyor 3 television cable

    Science.gov (United States)

    Gross, F. C.; Park, J. J.

    1972-01-01

    A sample of cable described as four inches of TV cable, fabric wrapped, which had been exposed to the atmosphere for an unknown period of time, was subjected to extensive chemical analyses for the various components. The fabric was tested using attenuated total reflectance, chloroform extract, aqueous extraction, pyrolysis infrared, and reflectance spectroscopy. The wire insulation was tested using pyrolysis infrared, pyrolysis gas chromatography, differential thermal analysis, attenuated total reflectance subsurface, and tensile tests. Corrosion was also observed in parts of certain wires.

  20. Reconfigurable Buoyant Cable Antenna with Improved Gain

    Science.gov (United States)

    2010-07-28

    consists of a number of connected streamer cable sections, which each comprise a mechanical jacket surrounding a hollow core enclosing seismic sensor and...of insulation. A buoyancy layer/ jacket is either injection molded or extruded in place onto the core to make the final structure a solid object...systems: [0008] U.S. Patent No. 5,745,436, issued April 28, 1998, to Bittleston, discloses a semi-dry marine seismic streamer cable that

  1. A Cable-Shaped Lithium Sulfur Battery.

    Science.gov (United States)

    Fang, Xin; Weng, Wei; Ren, Jing; Peng, Huisheng

    2016-01-20

    A carbon nanostructured hybrid fiber is developed by integrating mesoporous carbon and graphene oxide into aligned carbon nanotubes. This hybrid fiber is used as a 1D cathode to fabricate a new cable-shaped lithium-sulfur battery. The fiber cathode exhibits a decent specific capacity and lifespan, which makes the cable-shaped lithium-sulfur battery rank far ahead of other fiber-shaped batteries.

  2. Couplings in parametrically excited inclined cables systems

    OpenAIRE

    Michon, Guilhem; Berlioz, Alain; Lamarque, Claude-Henri

    2008-01-01

    Cables in stayed bridges are subjected to important dynamic solicitations for which dynamic model are now well established. Due to their design, such structures highlight resonance phenomena and instabilities frequently observed. Nevertheless, some structures exhibit important vibration amplitudes that can not be explained simply. Measurement recently performed on a bridge point a coupling of the cable with the deck or the pillar. The present paper suggests to consider the deck flexibility co...

  3. Cable system transients theory, modeling and simulation

    CERN Document Server

    Ametani, Akihiro; Nagaoka, Naoto

    2015-01-01

    A systematic and comprehensive introduction to electromagnetic transient in cable systems, written by the internationally renowned pioneer in this field Presents a systematic and comprehensive introduction to electromagnetic transient in cable systems Written by the internationally renowned pioneer in the field Thorough coverage of the state of the art on the topic, presented in a well-organized, logical style, from fundamentals and practical applications A companion website is available

  4. Rural Electric Network Alteration Spurs Cable Production

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    <正>Most aluminum cable enterprises in Yunnan and Zhejiang focus their production capacity on overhead cables needed in rural electric network alteration. During the 12th Five-Year Plan period, China launched the rural electric network alteration & upgrade project. As of the middle of 2011, the budget of the central government for the rural electric network alteration & upgrade project planned by the National Development and Reform Commission has reached up to RMB 64.96 billion.

  5. Ecology: Electrical Cable Bacteria Save Marine Life

    DEFF Research Database (Denmark)

    Nielsen, Lars Peter

    2016-01-01

    Animals at the bottom of the sea survive oxygen depletion surprisingly often, and a new study identifies cable bacteria in the sediment as the saviors. The bacterial electrical activity creates an iron 'carpet', trapping toxic hydrogen sulfide.......Animals at the bottom of the sea survive oxygen depletion surprisingly often, and a new study identifies cable bacteria in the sediment as the saviors. The bacterial electrical activity creates an iron 'carpet', trapping toxic hydrogen sulfide....

  6. Coaxial Cables for Martian Extreme Temperature Environments

    Science.gov (United States)

    Ramesham, Rajeshuni; Harvey, Wayne L.; Valas, Sam; Tsai, Michael C.

    2011-01-01

    Work was conducted to validate the use of the rover external flexible coaxial cabling for space under the extreme environments to be encountered during the Mars Science Laboratory (MSL) mission. The antennas must survive all ground operations plus the nominal 670-Martian-day mission that includes summer and winter seasons of the Mars environment. Successful development of processes established coaxial cable hardware fatigue limits, which were well beyond the expected in-flight exposures. In keeping with traditional qualification philosophy, this was accomplished by subjecting flight-representative coaxial cables to temperature cycling of the same depth as expected in-flight, but for three times the expected number of in-flight thermal cycles. Insertion loss and return loss tests were performed on the coaxial cables during the thermal chamber breaks. A vector network analyzer was calibrated and operated over the operational frequency range 7.145 to 8.450 GHz. Even though some of the exposed cables function only at UHF frequencies (approximately 400 MHz), the testing was more sensitive, and extending the test range down to 400 MHz would have cost frequency resolution. The Gore flexible coaxial cables, which were the subject of these tests, proved to be robust and displayed no sign of degradation due to the 3X exposure to the punishing Mars surface operations cycles.

  7. Two-way cable television system characterization

    Science.gov (United States)

    Schauer, Paul T.

    1995-11-01

    This presentation is a report of the testing activities of the CableLabs Network Integrity Working Group. The working group consisted of several CableLabs member companies which conducted rf analog and digital bit-error testing at five CATV networks in the U.S. and Canada. The purpose of the working group was to measure the reliability and availability of the contemporary CATV network as specified by traditional switched access telephony performance parameters. Transmission data was collected for both forward and reverse (sub- split) paths of the rf broadband network, in both traditional and hybrid fiber/coax architectures, and for baseline and controlled variation events. The basic premise of this testing was to ascertain which cable television network elements adversely affected transmission of a 'generic' digital communications system and how they can be managed or controlled. The digital transmission utilized in the test was a QPSK modulated, T-1 rate (1.544 Mbit/second), modem without error correction. The intent was not to derive the necessary modulation technique and error correction scheme to properly operate in every cable television system, but rather to determine the principal sources of impairments existing in these networks and deduce corrective measures. The full report of the Network Integrity Working Group is published by CableLabs, Inc., and is titled, 'Two-Way Cable Television System Characterization -- Final Report', April 1995.

  8. Development of HTS power cable using YBCO coated conductor

    Science.gov (United States)

    Mukoyama, Shinichi; Yagi, Masashi; Hirano, Hironobu; Yamada, Yutaka; Izumi, Teruo; Shiohara, Yuh

    2006-10-01

    Reductions of AC losses and of cost of HTS power cables are important to put it into practical power networks. Since an YBCO-coated-conductor (YBCO tape) has higher Jc and better magnetic property than a Bi2223-Ag-sheathed-tape, an AC power cable using YBCO tapes will obtain higher performance than XLPE-cables and HTS cables using BSCCO tapes in future. Especially, an YBCO HTS cable will be expected to become a higher economical cable than a Bi cable because an YBCO tape reduced its AC losses and its wire cost. We have started developing HTS power cables using YBCO tapes. Mechanical properties, superconducting properties and other electro magnetic properties of YBCO tapes have been measured to estimate the applicability to the HTS cable. Moreover, we have developed some technologies to bring out latent potentials of YBCO tapes.

  9. Development of Heat-resistant XLPE Cable and Accessories

    Science.gov (United States)

    Yamada, Hiroyuki; Nakagawa, Shinichi; Murata, Yoshinao; Kishi, Kouji; Katakai, Shoshi

    We have developed heat-resistant XLPE cable and accessories that can be operated at 105°C as the maximum permissible conductor temperature in normal operation. Through this cable system, greater transmission capacity can be achieved using existing cable ducts and without increasing the conductor size of the cable. We have developed heat-resistant XLPE insulation material which has a higher melting point than that of conventional XLPE. The breakdown strength of heat-resistant XLPE cable at 105°C is almost the same as that of conventional XLPE cable at 90°C. The heat deformation of the new cable at 105°C is almost the same as that of conventional XLPE cable at 90°C. Conventional self-pressurized rubber joints can be applied to heat-resistant cable lines with the new waterproof joint compound with low heat resistivity.

  10. Full-scale fire experiments on vertical horizontal cable trays

    Energy Technology Data Exchange (ETDEWEB)

    Mangs, J.; Keski-Rahkonen, O. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1997-10-01

    Two full-scale fire experiments on PVC cables used in nuclear power plants were carried out, one with cables in vertical position and one with cables in horizontal position. The vertical cable bundle, 3 m high, 300 mm wide and 30 mm thick, was attached to a steel cable ladder. The vertical bundle experiment was carried out in nearly free space with three walls near the cable ladder guiding air flow in order to stabilise flames. The horizontal cable experiment was carried out in a small room with five cable bundles attached to steel cable ladders. Three of the 2 m long cable bundles were located in an array, equally spaced above each other near one long side of the room and two correspondingly near the opposite long side. The vertical cable bundle was ignited with a small propane gas burner beneath the lower edge of the bundle. The horizontal cable bundles were ignited with a small propane burner beneath the lowest bundle in an array of three bundles. Rate of heat release by means of oxygen consumption calorimetry, mass change, CO{sub 2}, CO and smoke production rate and gas, wall and cable surface temperatures were measured as a function of time, as well as time to sprinkler operation and failure of test voltage in cables. Additionally, the minimum rate of heat release needed to ignite the bundle was determined. This paper concentrates on describing and recording the experimental set-up and the data obtained. (orig.)

  11. Application study on the first cable-stayed bridge with CFRP cables in China

    Directory of Open Access Journals (Sweden)

    Kuihua Mei

    2015-08-01

    Full Text Available In order to push forward the development of CFRP cable-stayed bridge and accumulate experiences, the study on the application of the first cable-stayed bridge with CFRP cables in China was carried out. The design essentials of main components of the bridge were introduced and its integral performances, including static properties, dynamic properties and seismic response were analyzed using finite element method. A new bond-type anchorage was developed and the processes of fabricating and installing CFRP cables were elaborated. Based on the results of construction simulation, a tension scheme for bridge was propound. During constructing, the stresses and displacement of girder and pylon, as well as the forces and stresses of cables, were tested. The results indicate that all sections of the bridge could meet the requirements of the ultimate bearing capacity and normal service; the performance of the anchorage is good and the stresses in each cable system are similar; the tested values accord well with the calculated values. Further, creep deformation of the resin in anchorages under service load is not obvious. All these results demonstrate that the first application of CFRP cables in the cable-stayed bridge in China is successful.

  12. Study on longitudinal wind load calculation method of cables for cable-stayed bridge

    Institute of Scientific and Technical Information of China (English)

    Pei Minshan; Zhang Xigang; Zhu Bin; Hou Bin; Liu Changpeng

    2009-01-01

    Along with the expanding of span of cable-stayed bridge, wind load becomes a more and more important controlling factor for bridge the design. A very large proportion of the wind load acting on cables has exceeded that acting on deck. There was not any detailed prescript in Chinese code for calculation of longitudinal wind load on cables due to lack of theoretical research and experiment, and conservative simplified calculation was adopted during design, which leads to conservative and uneconomical design of structures. To resolve this problem, cable force experiment was carried out during the design of Sutong Bridge. By comparing with international research results, the calculation formula of longitudinal wind drag coefficient for cables was advanced to fill the blank of bridge wind resistant code of China, and has already been adopted in the Highway Bridge Wind Resistant Design Code (JTG/T D60-01-2004) with great significance for bridge engineering.

  13. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  14. Results from the Danish high temperature superconducting power cable project

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Østergaard, Jacob

    2002-01-01

    For the first time, a high temperature superconducting (HTS) demonstration cable system has been installed in a utility network supplying electricity to consumers. The cable is a 30-m long, 30kVrms, 2, 000Arms cable, installed in the network of Copenhagen Energy at a substation supplying approxim......For the first time, a high temperature superconducting (HTS) demonstration cable system has been installed in a utility network supplying electricity to consumers. The cable is a 30-m long, 30kVrms, 2, 000Arms cable, installed in the network of Copenhagen Energy at a substation supplying...

  15. Energy losses of superconducting power transmission cables in the grid

    DEFF Research Database (Denmark)

    Østergaard, Jacob; Okholm, Jan; Lomholt, Karin

    2001-01-01

    One of the obvious motives for development of superconducting power transmission cables is reduction of transmission losses. Loss components in superconducting cables as well as in conventional cables have been examined. These losses are used for calculating the total energy losses of conventional...... as well as superconducting cables when they are placed in the electric power transmission network. It is concluded that high load connections are necessary to obtain energy saving by the use of HTSC cables. For selected high load connections, an energy saving of 40% is expected. It is shown...... that the thermal insulation and cooling machine efficiency are the most important loss element in a superconducting cable system...

  16. High voltage pulsed cable design: a practical example

    Energy Technology Data Exchange (ETDEWEB)

    Kewish, R.W. Jr.; Boicourt, G.P.

    1979-01-01

    The design of optimum high voltage pulse cable is difficult because very little emperical data are available on performance in pulsed applications. This paper follows the design and testing of one high voltage pulse cable, 40/100 trigger cable. The design was based on an unproven theory and the impressive outcome lends support to the theory. The theory is outlined and it is shown that there exists an inductance which gives a cable of minimum size for a given maximum stress. Test results on cable manufactured according to the design are presented and compared with the test results on the cable that 40/100 replaces.

  17. Evaluation of cable ageing in Nuclear Power Plants; Evaluacion del envejecimiento de cables en centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Vergara, T. [Empresarios Agrupados, A. I. E. Madrid (Spain); Alonso Chicote, J. [TECNATOM, S. A. (Spain); Burnay, S. [AEA Technology (UK)

    2000-07-01

    The majority of power, control and instrumentation cables in nuclear power plants use polymers as their basic material for insulation and jacket. In many cases, these cables form part of safety-related circuits and should therefore be capable of operating correctly under both normal and accident conditions. Since polymeric materials are degraded by the long term action of the radiation and thermal environments found in the plant, it is important to be able to establish the cable condition during the plant lifetime. Nowadays there are a number of different methods to evaluate the remaining lifetime of cables. In the case of new plants, or new cables in old plants, accelerated ageing tests and predictive models can be used to establish the behaviour of the cable materials under operating conditions. There are verified techniques and considerable experience in the definition of predictive models. This type of approach is best carried out during the commissioning stage or in the early stages of operation. In older plants, particularly where there is a wide range of cable types in use, it is more appropriate to use condition monitoring methods to establish the state of degradation of cables in-plant. Over the last 10 years there have been considerable developments in methods for condition monitoring of cables and a tool-box of practical techniques are now available. There is no single technique which is suitable for all cable materials but the range of methods covers nearly all of the types currently in use, at present, the most established methods are the indented, thermal analysis (OIT, OITP and TGA) and dielectric loss measurements, All of these are either non-destructive methods or require only micro-samples of material. (Author) 15 refs.

  18. Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jones, Anthony M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-01

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages

  19. Recent progress of HTS cable project

    Science.gov (United States)

    Masuda, T.; Yumura, H.; Watanabe, M.

    2008-09-01

    A lot of developments of HTS wires and their applications have been conducted since the discovery of HTS materials in the world. It has been recently reported that critical current of BSCCO wires improved to more than 200 A at 77 K and a large amount of wire was provided with high quality as industrial products. This improvement can be expected to accelerate the commercialization of HTS applications such as an HTS cable, HTS motor and so on. As the proofs of such trends, Sumitomo Electric constructed two HTS cable systems and started their operations in the USA and Korea last year. One of them is the HTS cable in Albany, NY, which has a capacity of 34.5 kV and 800 A and 350 m in length. It has been operated in a real grid without any trouble for 9 months. The other is the HTS cable in Korea, which has a capacity of 22.9 kV and 1250 A and 100 m in length. Its operation also started in the KEPCO testing yard last year. These results demonstrate reliance and stability of its operation. Recently, a new national project of an HTS cable has just started in Japan to demonstrate the operation in a real grid and study the system operations including a monitoring method, an alarm system, a maintenance method, etc. This paper reports the results of Albany and Korea projects and an outline of the new project.

  20. Distance and Cable Length Measurement System

    Directory of Open Access Journals (Sweden)

    Jonay Toledo

    2009-12-01

    Full Text Available A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement.

  1. Reusable Hot-Wire Cable Cutter

    Science.gov (United States)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  2. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  3. Wire and Cable Cold Bending Test

    Science.gov (United States)

    Colozza, Anthony

    2010-01-01

    One of the factors in assessing the applicability of wire or cable on the lunar surface is its flexibility under extreme cold conditions. Existing wire specifications did not address their mechanical behavior under cold, cryogenic temperature conditions. Therefore tests were performed to provide this information. To assess this characteristic 35 different insulated wire and cable pieces were cold soaked in liquid nitrogen. The segments were then subjected to bending and the force was recorded. Any failure of the insulation or jacketing was also documented for each sample tested. The bending force tests were performed at room temperature to provide a comparison to the change in force needed to bend the samples due to the low temperature conditions. The results from the bending tests were plotted and showed how various types of insulated wire and cable responded to bending under cold conditions. These results were then used to estimate the torque needed to unroll the wire under these low temperature conditions.

  4. Analysis of Electrical Coupling Parameters in Superconducting Cables

    CERN Document Server

    Bottura, L; Rosso, C

    2003-01-01

    The analysis of current distribution and redistribution in superconducting cables requires the knowledge of the electric coupling among strands, and in particular the interstrand resistance and inductance values. In practice both parameters can have wide variations in cables commonly used such as Rutherford cables for accelerators or Cable-in-Conduits for fusion and SMES magnets. In this paper we describe a model of a multi-stage twisted cable with arbitrary geometry that can be used to study the range of interstrand resistances and inductances that is associated with variations of geometry. These variations can be due to cabling or compaction effects. To describe the variations from the nominal geometry we have adopted a cable model that resembles to the physical process of cabling and compaction. The inductance calculation part of the model is validated by comparison to semi-analytical results, showing excellent accuracy and execution speed.

  5. 75 FR 59099 - Cable Television Act of 1992

    Science.gov (United States)

    2010-09-27

    ...This document announces the effective date of rules published in the Federal Register on October 5, 1995. The Commission simplified rules affecting cable operators' rates and provided cable operators with an additional option for adjusting their rates.

  6. 78 FR 11988 - Cable Television Act of 1992

    Science.gov (United States)

    2013-02-21

    ...This document announces the effective date of rules published in the Federal Register on October 5, 1995. The Commission simplified rules affecting cable operators' rates and provided cable operators with an additional option for adjusting their rates.

  7. Optimal Energy Harvesting from Vortex-Induced Vibrations of Cables

    CERN Document Server

    Antoine, G O; Michelin, S

    2016-01-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable's geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable's ends, relying on deformation waves along the cable to carry the energy toward this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with ...

  8. Low Friction Cryostat for HTS Power Cable of Dutch Project

    DEFF Research Database (Denmark)

    Chevtchenko, Oleg; Zuijderduin, Roy; Smit, Johan;

    2012-01-01

    Particulars of 6km long HTS AC power cable for Amsterdam project are: a cable has to fit in an annulus of 160mm, with only two cooling stations at the cable ends [1]. Application of existing solutions for HTS cables would result in excessively high coolant pressure drop in the cable, possibly...... affecting public acceptance of the project. In order to solve this problem, a model cryostat was developed consisting of alternating rigid and flexible sections and hydraulic tests were conducted using sub-cooled liquid nitrogen. In the 47 m-long cryostat, containing a full-size HTS cable model, measured....... A flexible dummy HTS cable was inserted into this cryostat and sub-cooled liquid nitrogen was circulated in the annulus between the dummy cable surface and the inner cryostat surface. In the paper details are presented of the cryostat, of the measurement setup, of the experiment and of the results....

  9. OVERLOAD CAPABILITY OF POWER CABLES IN ACTUAL POWER CONSUMPTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    L.A. Szhebenyuk

    2013-09-01

    Full Text Available Results of overload capability calculations for 6-kV power cables are analyzed. The work is aimed at creating a computation system for the current rating of high-voltage cross-linked polyethylene power cables.

  10. Dynamic Analysis of Towed and Variable Length Cable Systems

    Institute of Scientific and Technical Information of China (English)

    WANG Shu-xin; WANG Yan-hui; LI Xiao-ping

    2007-01-01

    Towed cable systems are frequently used in marine measurements where the length of the towed cable varies during launch and recovery. In this paper a novel method for modeling variable length cable systems is introduced based on the finite segment formulation. The variable length of the towed cable is described by changing the length of the segment near the towing point and by increasing or decreasing the number of the discrete segments of the cable. In this way, the elastic effects of the cable can be easily handled since geometry and material properties of each segment are kept constant. Experimental results show that the dynamic behavior of the towed cable is consistent between the model and the physical cable. Results show that the model provides numerical efficiency and simulation accuracy for the variable length towed system.

  11. Nonlinear dynamic response of stay cables under axial harmonic excitation

    Institute of Scientific and Technical Information of China (English)

    Xu XIE; He ZHAN; Zhi-cheng ZHANG

    2008-01-01

    This paper proposes a new numerical simulation method for analyzing the parametric vibration of stay cables based on the theory of nonlinear dynamic response of structures under the asynchronous support excitation.The effects of important parameters related to parametric vibration of cables,I.e., characteristics of structure,excitation frequency,excitation amplitude,damping effect of the air and the viscous damping coefficient of the cables,were investigated by using the proposed method for the cables with significant length difference as examples.The analysis results show that nonlinear finite element method is a powerful technique in analyzing the parametric vibration of cables,the behavior of parametric vibration of the two cables with different Irvine parameters has similar properties,the amplitudes of parametric vibration of cables are related to the frequency and amplitude of harmonic support excitations and the effect of distributed viscous damping on parametric vibration of the cables is very small.

  12. Smaller but Fully Functional Backshell for Cable Connector

    Science.gov (United States)

    Stephenson, Gregory

    2009-01-01

    An improved design for the backshell of a connector for a shielded, multiplewire cable reduces the size of the backshell, relative to traditional designs of backshells of otherwise identical cable connectors. Notwithstanding the reduction in size, the design provides all the functionality typically demanded of such a backshell, including (1) termination of the cable shield (that is, grounding of the shield to the backshell), (2) strain relief for the cable, and (3) protection against electromagnetic interference (EMI).

  13. The Protection of Undersea Cables: A Global Security Threat

    Science.gov (United States)

    2012-03-07

    and France in 1850, by the Gutta Percha manufacturing company.11 The cable was wrapped in a natural rubber (Gutta Percha) which was an effective ...maintain position in weather conditions up to Beaufort number 7 sea state, while laying and/or repairing cables.23 Since cable repairs are not...Keynote address at the “Global Summit on Reliability of Global Undersea Communications Cable Infrastructure (ROGUCCI) conference,” Dubai , U.A.E

  14. Electrothermal Coordination in Cable Based Transmission Grids

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt; Holbøll, Joachim; Gudmundsdottir, Unnur Stella

    2013-01-01

    Electrothermal coordination (ETC) is introduced for cable based transmission grids. ETC is the term covering operation and planning of transmission systems based on temperature, instead of current. ETC consists of one part covering the load conditions of the system and one covering the thermal...... to be beneficial for both operator and system planner. It is shown how the thermal behavior can be monitored in real-time during normal dynamic load and during emergencies. In that way, ETC enables cables to be loaded above their normal rating, while maintaining high reliability of the system, which potentially...

  15. Future services for cable television networks

    Science.gov (United States)

    Powell, William H.

    1995-11-01

    This paper examines the evolutionary potential of hybrid fiber coaxial systems for new services. It is shown that the cost of building dual (or 'overlay') cable TV and telecom networks is higher than adding telephony to a cable TV network on the hybrid fiber coax principle. It is shown that other services including Ethernet access to the Internet can also be added at low incremental cost. The potential of modems carrying ATM traffic to carry an even wider range of services is also considered.

  16. Under Ground Cable Sizing Using MAT LAB

    Directory of Open Access Journals (Sweden)

    B. V. R. Uday Kiran

    2014-06-01

    Full Text Available The main theme of this paper is to explain the procedure to calculate the cross sectional area of a conductor of an underground cable for a specified power & voltage ratings. This paper will also explain one of the simplest ways to calculate the cross section. In this paper we analyzed various factors that effect in deciding the ampacity of the conductor. We developed a Mat lab code to find the cross sectional area by including some of the parameters and also the voltage drop , maximum permissible voltage drop for that size of the conductor and also the number of runs of the cable that are to be laid.

  17. Dynamic Loadability of Cable Based Transmission Grids

    DEFF Research Database (Denmark)

    Olsen, Rasmus Schmidt

    This thesis is the product of three years research within the field of dynamic loadability of cable based transmission grids. The report contains a summary of the three year PhD project which has been conducted in a collaboration between the Danish Transmission System Operator (TSO), Energinet...... supervised 2 master projects, as well as 5 special courses at DTU. Furthermore I created and taught a cable course, with approximately 25 students, throughout 13 weeks during the spring of 2011. The PhD project has until now contributed with 3 journal papers and 4 conference papers. Selected papers can...

  18. Environmental Impact of a Submarine Cable: Case Study of the Acoustic Thermometry of Ocean Climate (ATOC)/ Pioneer Seamount Cable

    Science.gov (United States)

    Kogan, I.; Paull, C. K.; Kuhnz, L.; von Thun, S.; Burton, E.; Greene, H. G.; Barry, J. P.

    2003-12-01

    To better understand the potential impacts of the presence of cables on the seabed, a topic of interest for which little data is published or publicly available, a study of the environmental impacts of the ATOC/Pioneer Seamount cable was conducted. The 95 km long, submarine, coaxial cable extends between Pioneer Seamount and the Pillar Point Air Force Station in Half Moon Bay, California. Approximately two thirds of the cable lies within the Monterey Bay National Marine Sanctuary. The cable is permitted to NOAA- Oceanic and Atmospheric Research for transmitting data from a hydrophone array on Pioneer Seamount to shore. The cable was installed unburied on the seafloor in 1995. The cable path crosses the continental shelf, descends to a maximum depth of 1,933 m, and climbs back upslope to 998 m depth near the crest of Pioneer Seamount. A total of 42 hours of video and 152 push cores were collected in 10 stations along cable and control transects using the ROVs Ventana and Tiburon equipped with cable-tracking tools. The condition of the cable, its effect on the seafloor, and distribution of benthic megafauna and infauna were determined. Video data indicated the nature of interaction between the cable and the seafloor. Rocky nearshore areas, where wave energies are greatest, showed the clearest evidence of impact. Here, evidence of abrasion included frayed and unraveling portions of the cable's armor and vertical grooves in the rock apparently cut by the cable. The greatest incision and armor damage occurred on ledges between spans in irregular rock outcrop areas. Unlike the nearshore rocky region, neither the rocks nor the cable appeared damaged along outcrops on Pioneer Seamount. Multiple loops of slack cable added during a 1997 cable repair operation were found lying flat on the seafloor. Several sharp kinks in the cable were seen at 240 m water depths in an area subjected to intense trawling activity. Most of the cable has become buried with time in sediment

  19. Broadcast Service Areas, Cable, cable, Published in Not Provided, 1:600 (1in=50ft) scale, Comcast.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Broadcast Service Areas, Cable dataset, published at 1:600 (1in=50ft) scale as of Not Provided. It is described as 'cable'. Data by this publisher are often...

  20. Working Paper for the Revision of San Francisco's Cable Franchise.

    Science.gov (United States)

    San Francisco Public Library, CA. Video Task Force.

    Ideas are presented for the revision of San Francisco's cable franchise. The recommendations in the report are based upon national research of library and urban use of cable communications and are designed to help the city's present and future cable franchises to comply with the regulations of the Federal Communications Commission by March 31,…

  1. Forced vibration of a ball attached to a cable

    Directory of Open Access Journals (Sweden)

    Douglas Oliver

    2000-01-01

    Full Text Available This work describes an analytic solution to predict the forced oscillation of a suspended cable and an attached ball. The oscillations are driven by a sinusoidal movement at the fixed end of the cable. This problem may be used in the verification of numerical software which is commonly used to design systems with suspended cables.

  2. Results from the Danish high temperature superconducting power cable project

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Østergaard, Jacob

    2002-01-01

    For the first time, a high temperature superconducting (HTS) demonstration cable system has been installed in a utility network supplying electricity to consumers. The cable is a 30-m long, 30kVrms, 2, 000Arms cable, installed in the network of Copenhagen Energy at a substation supplying approxim...

  3. 30 CFR 75.600 - Trailing cables; flame resistance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables; flame resistance. 75.600 Section 75.600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... cables; flame resistance. Trailing cables used in coal mines shall meet the requirements established...

  4. 30 CFR 75.600-1 - Approved cables; flame resistance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved cables; flame resistance. 75.600-1 Section 75.600-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... cables; flame resistance. Cables shall be accepted or approved by MSHA as flame resistant....

  5. FCC Commissioner, Legal Assistant and Staff Perceptions of Cable TV.

    Science.gov (United States)

    Krugman, Dean M.

    1979-01-01

    Describes a methodology used in interviewing Federal Communications Commission commissioners, legal assistants, and Cable Bureau staff members about their attitudes toward the cable industry and regulation; reports results of the interviews, noting respondents' disappointment in the lack of cable growth. (GT)

  6. 46 CFR 111.60-21 - Cable insulation tests.

    Science.gov (United States)

    2010-10-01

    ...-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-21 Cable insulation tests. All cable for electric power and lighting and associated equipment must be checked for proper insulation resistance to... 46 Shipping 4 2010-10-01 2010-10-01 false Cable insulation tests. 111.60-21 Section...

  7. 46 CFR 129.340 - Cable and wiring.

    Science.gov (United States)

    2010-10-01

    ... section, the insulation resistance of the remainder of the cable is measured, and the condition of the insulation is unimpaired. (m) All material in a cable splice must be chemically compatible with other material in the splice and with the materials in the cable. (n) Ampacities for conductors must comply...

  8. 46 CFR 120.340 - Cable and wiring requirements.

    Science.gov (United States)

    2010-10-01

    ... insulation is unimpaired. (n) All material in a cable splice must be chemically compatible with all other material in the splice and with the materials in the cable. (o) Ampacities of wires must meet Section 310... to replace a damaged section of the cable if, before replacing the damaged section, the...

  9. Cable Television 1980: Status and Prospect for Higher Education.

    Science.gov (United States)

    Baus, F., Ed.

    Baseline information for the would-be cable television educational programer is provided by two papers, one an overview of the state of the cable television industry, and the other a report on a marketing study conducted to determine consumer attitudes toward cable TV as an educational medium. In "The Promise and Reality of Cable…

  10. 7 CFR 2902.43 - Chain and cable lubricants.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Chain and cable lubricants. 2902.43 Section 2902.43... Items § 2902.43 Chain and cable lubricants. (a) Definition. Products designed to provide lubrication in... and cable lubricants. By that date, Federal agencies that have the responsibility for drafting...

  11. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance...

  12. Regulation of Cable Television by the State of New York.

    Science.gov (United States)

    Jones, William K.

    In order to determine the appropriate role for the State of New York in relation to cable television, a comprehensive report was prepared for the state Public Service Commission by one of its members. In addition to background detail on the technology and potential of cable television, the report investigates current cable systems and current…

  13. Uses and Values for News on Cable Television.

    Science.gov (United States)

    Baldwin, Thomas F.; And Others

    1992-01-01

    Discusses cable television subscribers' perceptions and consumption patterns of television news and describes a survey that compared broadcast and cable television news viewing habits. Media dependency and media consumption are considered, attitudes toward news sources and the perceived monetary value of the Cable News Network (CNN) are studied,…

  14. 78 FR 11987 - Cable Television Act of 1992

    Science.gov (United States)

    2013-02-21

    ...This document announces the effective date of rules published in the Federal Register on December 6, 1994. The final rules revised to provide cable operators with additional incentives to expand their facilities and services in a way that both ensures that cable rates are reasonable and expands the opportunities for cable programmers to reach viewers.

  15. 46 CFR 111.60-6 - Fiber optic cable.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fiber optic cable. 111.60-6 Section 111.60-6 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-6 Fiber optic cable. Each fiber optic cable must— (a)...

  16. Cable Television: Technical Considerations in Franchising Major Market Systems.

    Science.gov (United States)

    Pilnick, Carl

    The 1972 Federal Communications Commission's (FCC) regulations on cable television were intended to assist the penetration of cable television into the large metropolitan regions of the United States. In these major market areas, the task for developing an appropriate franchise is complicated by the changing functional nature of the cable systems…

  17. 14 CFR 23.1365 - Electric cables and equipment.

    Science.gov (United States)

    2010-01-01

    ...) Electrical cables must be installed such that the risk of mechanical damage and/or damage cased by fluids... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electric cables and equipment. 23.1365... Electrical Systems and Equipment § 23.1365 Electric cables and equipment. (a) Each electric connecting...

  18. A Marriage Proposal: Cable Television and Local Public Power.

    Science.gov (United States)

    Schwartz, Louis; Woods, Robert A.

    Two articles reprinted from "Public Power" discuss the present state of cable television (TV), its future prospects, and the opportunities offered municipal utilities by cable TV. The proposal is that local publicly-owned electric utilities meet the requirements of the Federal Communications Commission (FCC) for cable TV ownership and have the…

  19. Measurements for validation of high voltage underground cable modelling

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Gudmundsdottir, Unnur Stella; Wiechowski, Wojciech Tomasz

    2009-01-01

    This paper discusses studies concerning cable modelling for long high voltage AC cable lines. In investigating the possibilities of using long cables instead of overhead lines, the simulation results must be trustworthy. Therefore a model validation is of great importance. This paper describes...

  20. 46 CFR 111.60-19 - Cable splices.

    Science.gov (United States)

    2010-10-01

    ... with section 25.11 of IEEE 45-2002 (incorporated by reference; see 46 CFR 110.10-1). ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable splices. 111.60-19 Section 111.60-19 Shipping... REQUIREMENTS Wiring Materials and Methods § 111.60-19 Cable splices. (a) A cable must not be spliced in...

  1. 47 CFR 32.6422 - Underground cable expense.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Underground cable expense. 32.6422 Section 32.6422 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM... Underground cable expense. (a) This account shall include expenses associated with underground cable....

  2. 30 CFR 75.817 - Cable handling and support systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Cable handling and support systems. 75.817... High-Voltage Longwalls § 75.817 Cable handling and support systems. Longwall mining equipment must be provided with cable-handling and support systems that are constructed, installed and maintained to...

  3. Damage Detection for Long-Span Cable-Stayed Bridge

    Institute of Scientific and Technical Information of China (English)

    Zhao Ling; Li Aiqun; Miao Changqing; Wang Yonglan

    2006-01-01

    Based on the updated finite-element model of a cable-stayed bridge, this study investigates the technique of identifying damage existing in cable or girder by means of numerical simulation. The modal analysis is performed to identify the changes in modal frequencies and curvatures caused by damage, and the static analysis is executed to detect the influence of damage on cable force. The results indicate a relatively significant decrease in frequencies of lower vertical bending modes due to the damage in cable and little change of frequencies due to damage in girder. Different sensitivities to the location of damaged cable are observed from the frequency changes of different bending modes, which can be used to initially locate the damaged cable. The damage in either cable or girder can be further localized by the most significant change in curvature of girder. The damage occurred in a cable produces a remarkable change in force of nearby cables, whereas the damage in girder brings little change of cable forces. In addition, a pragmatic approach for localizing the damage in girder or cable is proposed based on a comprehensive utilization of the changes in frequency of vertical bending modes, modal curvature of girder, and force in cables.

  4. 47 CFR 32.6426 - Intrabuilding network cable expense.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Intrabuilding network cable expense. 32.6426... Intrabuilding network cable expense. (a) This account shall include expenses associated with intrabuilding network cable. (b) Subsidiary record categories shall be maintained as provided in § 32.2426(a) of...

  5. 47 CFR 32.6423 - Buried cable expense.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Buried cable expense. 32.6423 Section 32.6423... FOR TELECOMMUNICATIONS COMPANIES Instructions for Expense Accounts § 32.6423 Buried cable expense. (a) This account shall include expenses associated with buried cable. (b) Subsidiary record...

  6. 47 CFR 32.6421 - Aerial cable expense.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Aerial cable expense. 32.6421 Section 32.6421... FOR TELECOMMUNICATIONS COMPANIES Instructions for Expense Accounts § 32.6421 Aerial cable expense. (a) This account shall include expenses associated with aerial cable. (b) Subsidiary record...

  7. 46 CFR 113.10-3 - Cable runs.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs...

  8. Perturbation of near-field scan from connected cables

    DEFF Research Database (Denmark)

    Sørensen, Morten; Franek, Ondrej; Pedersen, Gert Frølund;

    2012-01-01

    The perturbation of near-fields scan from connected cables are investigated and how to handle the cables is discussed. A connected cable induced small but theoretical detectable changes in the near-field. This change can be seen in Huygens’ box simulations (equivalent source currents on a box...

  9. 24 CFR 3285.704 - Telephone and cable TV.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Telephone and cable TV. 3285.704....704 Telephone and cable TV. Refer to § 3285.906 for considerations pertinent to installation of telephone and cable TV....

  10. 24 CFR 3285.906 - Telephone and cable TV.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Telephone and cable TV. 3285.906... Installation Instructions § 3285.906 Telephone and cable TV. It is recommended that the installation instructions explain that telephone and cable TV wiring should be installed in accordance with requirements...

  11. Using CNR to Realize the Cable Modem MAC Authentication%通过CNR实现Cable Modem MAC认证

    Institute of Scientific and Technical Information of China (English)

    赵天元

    2005-01-01

    基于Cable Modem的认证系统的开发一直相对滞后,这也相对制约了Cable Modem高级业务的发展.介绍了笔者对Cable Modem认证的一些新的思路及尝试,通过建立Cable Modem MAC认证弥补现有认证系统的不足.

  12. Broadband Wireline Provider Service: Cable Modem - Other; BBRI_cableOther12

    Data.gov (United States)

    University of Rhode Island Geospatial Extension Program — This dataset represents the availability of wireline broadband Internet access in Rhode Island via "Cable Modem - Other" technology. Broadband availability is...

  13. Broadband Wireline Provider Service: Cable Modem - DOCSIS 3.0; BBRI_cableDOCSIS12

    Data.gov (United States)

    University of Rhode Island Geospatial Extension Program — This dataset represents the availability of wireline broadband Internet access in Rhode Island via "Cable Modem - DOCSIS 3.0" technology. Broadband availability is...

  14. Compensation of Cable Voltage Drops and Automatic Identification of Cable Parameters in 400 Hz Ground Power Units

    DEFF Research Database (Denmark)

    Borup, Uffe; Nielsen, Bo Vork; Blaabjerg, Frede

    2004-01-01

    In this paper a new cable voltage drop compensation scheme for ground power units (GPU) is presented. The scheme is able to predict and compensate the voltage drop in an output cable by measuring the current quantities at the source. The prediction is based on an advanced cable model that includes...

  15. Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jones, Anthony M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-01

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages

  16. Modeling of Pressure Effects in HVDC Cables

    DEFF Research Database (Denmark)

    Szabo, Peter; Hassager, Ole; Strøbech, Esben

    1999-01-01

    A model is developed for the prediction of pressure effects in HVDC mass impregnatedcables as a result of temperature changes.To test the model assumptions, experiments were performed in cable like geometries.It is concluded that the model may predict the formation of gas cavities....

  17. Microminiature coaxial cable and methods of manufacture

    Science.gov (United States)

    Bongianni, W. L.

    1983-12-01

    A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 (MU)m thick and from 150 to 200 (MU)m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a continuous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

  18. Study on Impedance Characteristics of Aircraft Cables

    Directory of Open Access Journals (Sweden)

    Weilin Li

    2016-01-01

    Full Text Available Voltage decrease and power loss in distribution lines of aircraft electric power system are harmful to the normal operation of electrical equipment and may even threaten the safety of aircraft. This study investigates how the gap distance (the distance between aircraft cables and aircraft skin and voltage frequency (variable frequency power supply will be adopted for next generation aircraft will affect the impedance of aircraft cables. To be more precise, the forming mechanism of cable resistance and inductance is illustrated in detail and their changing trends with frequency and gap distance are analyzed with the help of electromagnetic theoretical analysis. An aircraft cable simulation model is built with Maxwell 2D and the simulation results are consistent with the conclusions drawn from the theoretical analysis. The changing trends of the four core parameters of interest are analyzed: resistance, inductance, reactance, and impedance. The research results can be used as reference for the applications in Variable Speed Variable Frequency (VSVF aircraft electric power system.

  19. Cable Television; A Guide for Citizen Action.

    Science.gov (United States)

    Price, Monroe E.; Wicklein, John

    When commercial radio began broadcasting, some citizens saw it as a new "golden age," offering vast opportunities for educational and public service programing. These dreams did not come true because it was more profitable to sell advertising. The same pattern occured with broadcast television. Cable television provides a third chance, and this…

  20. Cinema Futures: Cain, Abel or Cable?

    NARCIS (Netherlands)

    Elsaesser, Thomas; Hoffmann, Kay

    1998-01-01

    In the late 1960s, the cinema was pronounced dead. Television, like a Biblical Cain had slain his brother Abel. Some thirty years later, a remarkable reversal: rarely has the cinema been more popular. And yet, rarely has the cinema's future seemed more uncertain. Cinema Futures: Cain, Abel or Cable?

  1. Coil-Type Asymmetric Supercapacitor Electrical Cables.

    Science.gov (United States)

    Yu, Zenan; Moore, Julian; Calderon, Jean; Zhai, Lei; Thomas, Jayan

    2015-10-21

    Cable-shaped supercapacitors (SCs) have recently aroused significant attention due to their attractive properties such as small size, lightweight, and bendability. Current cable-shaped SCs have symmetric device configuration. However, if an asymmetric design is used in cable-shaped supercapacitors, they would become more attractive due to broader cell operation voltages, which results in higher energy densities. Here, a novel coil-type asymmetric supercapacitor electrical cable (CASEC) is reported with enhanced cell operation voltage and extraordinary mechanical-electrochemical stability. The CASECs show excellent charge-discharge profiles, extraordinary rate capability (95.4%), high energy density (0.85 mWh cm(-3)), remarkable flexibility and bendability, and superior bending cycle stability (≈93.0% after 4000 cycles at different bending states). In addition, the CASECs not only exhibit the capability to store energy but also to transmit electricity simultaneously and independently. The integrated electrical conduction and storage capability of CASECS offer many potential applications in solar energy storage and electronic gadgets. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Securing Europe’s Cable Future

    NARCIS (Netherlands)

    Nijs, J.M.M. de; Gyselings, T.; Engelke, C.

    2009-01-01

    Since the very first network roll-outs, cable operators have proved their capability to closely follow market developments: every time that the network capabilities started falling back on consumer requirements, the networks were successfully upgraded. As such, operators are familiar with upgrades,

  3. Cinema Futures: Cain, Abel or Cable?

    NARCIS (Netherlands)

    Elsaesser, Thomas; Hoffmann, Kay

    1998-01-01

    In the late 1960s, the cinema was pronounced dead. Television, like a Biblical Cain had slain his brother Abel. Some thirty years later, a remarkable reversal: rarely has the cinema been more popular. And yet, rarely has the cinema's future seemed more uncertain. Cinema Futures: Cain, Abel or Cable?

  4. Cable TV: A Valuable Learning Resource.

    Science.gov (United States)

    Baca, Milton L.; Palmer, Gregory

    1985-01-01

    Valley High School, Albuquerque, New Mexico, uses cable television in many ways. The educational access channels aid in classroom instruction, students take part in national and local teleconferences, the public access channel is used to tell the community about the school, and students learn to use video equipment. (DCS)

  5. History of cable-stayed bridges

    DEFF Research Database (Denmark)

    Gimsing, Niels Jørgen

    1999-01-01

    The principle of supporting a bridge deck by inclined tension members leading to towers on either side of the span has been known for centuries. However, the real development of cable-stayed bridges did not begin before the 1950s. Since then the free span has been increased from 183 m in the Strö...

  6. Dutch VULA consumer market services over Cable

    NARCIS (Netherlands)

    Anoniem

    2015-01-01

    KPN offers a virtual unbundled local access wholesale service over its DSL infrastructure. This offer has been accepted by the Dutch Authority Consumer Market. In the report, it is argued that for consumer market services, the Dutch cable providers can develop an equivalent wholesale service from th

  7. Space charge fields in DC cables

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C; Pedersen, Aage

    1996-01-01

    The space charge that accumulates in DC cables can, mathematically, be resolved into two components. One is related to the temperature and the other to the magnitude of the electric field strength. Analytical expressions for the electric fields arising from each of these space charge components a...

  8. Observation of polyphosphate granules in cable bacteria

    Science.gov (United States)

    Yang, T.; Nielsen, L. P.; Risgaard-Petersen, N.

    2015-12-01

    Cable bacteria are long filamentous bacteria that capable for long distance electron transport: transporting electrons derived from oxidizing sulfide in anoxic layers, to oxygen at the sediment surface, over a distance of centimeters. Cable bacteria are found in many types of freshwater and marine sediment all over the world, with density of approximately thousands of kilometers per square meter. These long filaments are composed by individual cells closely related to Desulfobulbaceae, connected with a shared outer membrane inside which the strings structure are presumed to be highly conductive. The observed doubling time of cells within the filament is about 20 min, which is among the shortest compare to other bacteria. In these cable cells, we constantly observed polyphosphate granules (poly-P), regardless of cell dimension and shape. This is very interesting since it has long been recognized that the microbial polyP content is low during rapid growth and increases under unfavorable conditions, for example, increasing sulfide concentration and anoxia resulted in a decomposition of poly-P in Beggiatoa. Here, we investigated marine cable bacteria from Netherland and Aarhus Bay, focusing on the poly-P dynamics under various redox conditions. In poly-P stained cells, typically there are two big poly-P granules locate at each polar. In dividing cells, however, the morphology of poly-P changed to six small granules precisely arranged to two row. Moreover, the cells seem be able to continuously divide more than one time without elongation step. These varied poly-P morphologies demonstrate that poly-P is closely related to the cell growth and cell division, by an unknown mechanism. Individual cable filaments were picked up and were exposed to different redox conditions; our primary data indicated the cable cells could suffer anoxic condition better than oxic condition. We also detected decomposition of poly-P under anoxia. These results call for an in-depth examination

  9. The cable catapult - Putting it there and keeping it there

    Science.gov (United States)

    Forward, Robert L.; Conley, Buford R.; Stanek, Clay; Ramsey, William

    1992-01-01

    The cable catapult is the previously proposed method of using long space tethers for high speed interplanetary transport. A long conductive multistrand cable would be connected to a power supply and pointed in the desired direction. A linear motor would pull itself along the powered cable strands and launch a payload capsule toward a distant planet, where it would be caught and decelerated by another cable catapult positioned there. In this paper it is shown how cable catapults can be used to transport themselves to a distant planet and keep themselves in position near the planet despite the tendency of the payload capsule momentum transfer to push them apart.

  10. Superconducting power cables in Denmark - a case study

    DEFF Research Database (Denmark)

    Østergaard, Jacob

    1997-01-01

    A case study of a 450 MVA, 132 kV high temperature superconducting (HTS) power transmission cable has been carried out. In the study, a superconducting cable system is compared to a conventional cable system which is under construction for an actual transmission line in the Danish grid. The study...... that HTS cables will be less expensive for high power ratings, have lower losses for lines with a high load, and have a reduced reactive power production. The use of superconducting cables in Denmark accommodate plans by the Danish utility to make a substantial conversion of overhead lines to underground...

  11. 2nd International Conference on Cable-Driven Parallel Robots

    CERN Document Server

    Bruckmann, Tobias

    2015-01-01

    This volume presents the outcome of the second forum to cable-driven parallel robots, bringing the cable robot community together. It shows the new ideas of the active researchers developing cable-driven robots. The book presents the state of the art, including both summarizing contributions as well as latest research and future options. The book cover all topics which are essential for cable-driven robots: Classification Kinematics, Workspace and Singularity Analysis Statics and Dynamics Cable Modeling Control and Calibration Design Methodology Hardware Development Experimental Evaluation Prototypes, Application Reports and new Application concepts

  12. Energy dispatching analysis of lightning surges on underground cables in a cable connection station

    Energy Technology Data Exchange (ETDEWEB)

    Hong-Chan Chang; Fu-Hsien Chen; Tai-Hsiang Chen [Department of Electrical Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd., Taipei (China); Cheng-Chien Kuo [Department of Electrical Engineering, St. John' s University, 499, Sec. 4, TamKing Rd., Tamsui, Taipei (China)

    2011-01-15

    The paper aimed to simulate the transient over-voltage phenomena which occur at 345 kV and 161 kV underground cables, when lighting strikes on or near the cable connection station, by using the Electro-Magnetic Transients Program (EMTP). A feasibility study on changing related parameters, as well as cable connections and grounding methods to reduce the impact caused by lightning strikes, will be thoroughly conducted. The various components required for a detailed simulation including; lightning surges, transmission line and tower, arrester, and underground cables are all considered. Then, the transient voltage of the cables will be analyzed under different situations including; connection methods, grounding locations, length of the grounding wire of arrester, and the grounding resistance for different locations. The simulation results show that the length of the grounding wire is more sensitive to the transient over-voltage which occurred when a common grounding topology was adopted. In contrast, the use of an independent grounding topology resulted in a reduction of the grounding resistance, which effectively decreased the over-voltage, thereby avoiding surpassing the shielding voltage level of the cable, caused by the rise of ground voltage. (author)

  13. Proposal for using commercial submarine telecommunications cables for monitoring earthquakes and tsunamis - the SMART cable concept

    Science.gov (United States)

    Tilmann, Frederik; Howe, Bruce; Butler, Rhett; Strollo, Angelo; Weinstein, Stuart

    2017-04-01

    Hundreds of thousands of kilometres of commercial telecommunications cables traverse the world's oceans, many of them crossing large ocean basins, which are otherwise poorly sampled by geophysical sensors (seismometers or pressure gauges), or running along active continental margins, where additional observations would be particularly valuable for allowing observation of subduction zone earthquakes and offshore plate deformation from the updip end. However, as of today these cables are unaware of their environment. These cables are equipped with repeaters spaced at 50 km intervals to boost the telecom signal, though. These repeaters in principle offer access to power and bandwidth, providing the opportunity to add sensor capability to future "SMART" cables (Science Monitoring and Reliable Telecommunications). In a workshop held in early November 2016 at the German Research Centre for Geosciences in Potsdam (GFZ) research scientists, practitioners from earthquake observatories and tsunami warning centers, and engineers discussed possible applications of such SMART cables both from the viewpoint of fundamental research, i.e. Earth imaging and the study of earthquake processes and possibly plate deformation, as well as technical aspects of possible implementations by drawing on the expertise of operators of existing cabled networks. In this presentation, we will summarise the outcomes of this workshop.

  14. Energy dispatching analysis of lightning surges on underground cables in a cable connection station

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hong-Chan, E-mail: hcchang@mail.ntust.edu.t [Department of Electrical Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd., Taipei, Taiwan (China); Chen, Fu-Hsien, E-mail: fu@mail.sju.edu.t [Department of Electrical Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd., Taipei, Taiwan (China); Kuo, Cheng-Chien, E-mail: cckuo@mail.sju.edu.t [Department of Electrical Engineering, St. John' s University, 499, Sec. 4, TamKing Rd., Tamsui, Taipei, Taiwan (China); Chen, Tai-Hsiang, E-mail: thchen@yahoo.com.t [Department of Electrical Engineering, National Taiwan University of Science and Technology, 43, Sec. 4, Keelung Rd., Taipei, Taiwan (China)

    2011-01-15

    The paper aimed to simulate the transient over-voltage phenomena which occur at 345 kV and 161 kV underground cables, when lighting strikes on or near the cable connection station, by using the Electro-Magnetic Transients Program (EMTP). A feasibility study on changing related parameters, as well as cable connections and grounding methods to reduce the impact caused by lightning strikes, will be thoroughly conducted. The various components required for a detailed simulation including; lightning surges, transmission line and tower, arrester, and underground cables are all considered. Then, the transient voltage of the cables will be analyzed under different situations including; connection methods, grounding locations, length of the grounding wire of arrester, and the grounding resistance for different locations. The simulation results show that the length of the grounding wire is more sensitive to the transient over-voltage which occurred when a common grounding topology was adopted. In contrast, the use of an independent grounding topology resulted in a reduction of the grounding resistance, which effectively decreased the over-voltage, thereby avoiding surpassing the shielding voltage level of the cable, caused by the rise of ground voltage.

  15. Sixty-four-Channel Inline Cable Tester

    Science.gov (United States)

    2008-01-01

    Faults in wiring are a serious concern for the aerospace and aeronautics (commercial, military, and civil) industries. A number of accidents have occurred because faulty wiring created shorts or opens that resulted in the loss of control of the aircraft or because arcing led to fires and explosions. Some of these accidents have resulted in the massive loss of lives (such as in the TWA Flight 800 accident). Circuits on the Space Shuttle have also failed because of faulty insulation on wiring. STS-93 lost power when a primary power circuit in one engine failed and a second engine had a backup power circuit fault. Cables are usually tested on the ground after the crew reports a fault encountered during flight. Often such failures result from vibration and cannot be replicated while the aircraft is stationary. It is therefore important to monitor faults while the aircraft is in operation, when cables are more likely to fail. Work is in progress to develop a cable fault tester capable of monitoring up to 64 individual wires simultaneously. Faults can be monitored either inline or offline. In the inline mode of operation, the monitoring is performed without disturbing the normal operation of the wires under test. That is, the operations are performed unintrusively and are essentially undetectable for the test signal levels are below the noise floor. A cable can be monitored several times per second in the offline mode and once a second in the inline mode. The 64-channel inline cable tester not only detects the occurrence of a fault, but also determines the type of fault (short/open) and the location of the fault. This will enable the detection of intermittent faults that can be repaired before they become serious problems.

  16. Optimal energy harvesting from vortex-induced vibrations of cables.

    Science.gov (United States)

    Antoine, G O; de Langre, E; Michelin, S

    2016-11-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable's geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable's ends, relying on deformation waves along the cable to carry the energy towards this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with a rigid cylinder device. This results from two passive control mechanisms inherent to the cable geometry: (i) the adaptability to the flow velocity of the fundamental frequencies of cables through the flow-induced tension and (ii) the selection of successive vibration modes by the flow velocity for cables with gravity-induced tension.

  17. Optimal energy harvesting from vortex-induced vibrations of cables

    Science.gov (United States)

    Antoine, G. O.; de Langre, E.; Michelin, S.

    2016-11-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable's geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable's ends, relying on deformation waves along the cable to carry the energy towards this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with a rigid cylinder device. This results from two passive control mechanisms inherent to the cable geometry: (i) the adaptability to the flow velocity of the fundamental frequencies of cables through the flow-induced tension and (ii) the selection of successive vibration modes by the flow velocity for cables with gravity-induced tension.

  18. Analysis of tensioned membrane structures considering cable sliding

    Institute of Scientific and Technical Information of China (English)

    宋昌永

    2003-01-01

    In routine design of tensioned membrane structures, the membrane is generally modeled using space membrane elements and the cables by space cable elements, with no sliding allowed between the membrane and the cables. On the other hand, large deflections are expected and sliding between the membrane and the cables is inevitable. In the present paper, the general finite element code ABAQUS was employed to investigate the influence of cable sliding on membrane surface on the structural behavior. Three analysis models were devised to fulfill this purpose: (1) The membrane element shares nodes with the cable element; (2) The cable can slide on the membrane surface freely (without friction) and (3) The cable can slide on the membrane surface, but with friction between the cable and the membrane. The sliding problem is modeled using a surface - based contact algorithm. The results from three analysis models are compared, showing that cable sliding has only little influence on the structure shape and on the stress distributions in the membrane. The main influence of cable sliding may be its effect on the dynamic behavior of tensioned membrane structures.

  19. RESPONSE CHARACTERISTICS OF WIND EXCITED CABLES WITH ARTIFICIAL RIVULET

    Institute of Scientific and Technical Information of China (English)

    顾明; 刘慈军; 徐幼麟; 项海帆

    2002-01-01

    A wind tunnel investigation of response characteristics of cables with artificial rivulet is presented.A series of cable section models of different mass and stiffness and damping ratio were designed with artificial rivulet.They were tested in smooth flow under different wind speed and yaw angle and for different position of artificial rivulet.The measured response of cable models was then analyzed and compared with the experimental results obtained by other researchers and the existing theories for wind-induced cable vibration.The results show that the measured response of horizontal cable models with artificial rivulet could be well predicted by Den Hartog' s galloping theory when wind is normal to the cable axis.For the wind with certain yaw angles, the cable models with artificial rivulet exhibit velocity-restricted response characteristics.

  20. Testing of 3-meter Prototype Fault Current Limiting Cables

    Energy Technology Data Exchange (ETDEWEB)

    Gouge, Michael J [ORNL; Duckworth, Robert C [ORNL; Demko, Jonathan A [ORNL; Rey, Christopher M [ORNL; Thompson, James R [ORNL; Lindsay, David T [ORNL; Tolbert, Jerry Carlton [ORNL; Willen, Dag [Ultera; Lentge, Heidi [Ultera; Thidemann, Carsten [Ultera; Carter, Bill [AMSC

    2009-01-01

    Two 3-m long, single-phase cables have been fabricated by Ultera from second generation (2G) superconductor supplied by American Superconductor. The first cable was made with two layers of 2G tape conductor and had a critical current of 5,750 A while the second cable had four layers and a critical current of 8,500 A. AC loss was measured for both cables at ac currents of up to 4 kArms. Ultera performed initial fault current studies of both cables in Denmark with limited currents in the range from 9.1 to 44 kA. Results from these tests will provide a basis for a 25-m long, three-phase, prototype cable to be tested at ORNL early next year and a 300-m long, fault current limiting, superconducting cable to be installed in a ConEd substation in New York City.

  1. submitter On Roebel Cable Geometry for Accelerator Magnet

    CERN Document Server

    Fleiter, J; Ballarino, A

    2016-01-01

    Roebel-type cables made of a ReBCO conductor are potential candidates for high-field accelerator magnets. The necessity to promote a large effective transverse section in a Roebel cable to avoid local overstress leading to degradation in electrical performance has been recently addressed. In this paper, a new geometry of meander tapes for a Roebel cable that enhances both the transverse effective section and the current margin at crossing segments is discussed. As Roebel cables are bent at the coil ends, the modulation of the bending radius of strands along the cable pitch leads to a shift of the strands with respect to each other. The shift magnitude is analytically investigated in this paper as a function of both cable features and coil geometry. Finally, the minimum transposition pitch of Roebel cables is determined on the basis of coil characteristics.

  2. Evaluation of foam-skin cables for aerial applications

    Science.gov (United States)

    Samuelson, G. R.

    Since the introduction of foam-skin filled cables, there has been considerable discussion within the Industry, both pro and con, regarding the acceptability of foam-skin filled cables for aerial application. This paper reports on results obtained from a study undertaken to evaluate the changes in transmission properties of such cables in a simulated aerial environment. Cable samples produced by six cable manufacturers using conventional, high-temperature drip-resistant filling compounds with a petrolatum base were subjected to temperature cycling from -40 F to 140 F. Transmission parameters were measured at 1, 150 and 772 kHz and compared to initial values. A solid polypropylene insulated filled cable was included for reference. The results show that foam-skin petrolatum based filled cables exhibit stable electrical characteristics when exposed to cycled temperature extremes.

  3. Analytical Solution for the Current Distribution in Multistrand Superconducting Cables

    CERN Document Server

    Bottura, L; Fabbri, M G

    2002-01-01

    Current distribution in multistrand superconducting cables can be a major concern for stability in superconducting magnets and for field quality in particle accelerator magnets. In this paper we describe multistrand superconducting cables by means of a distributed parameters circuit model. We derive a system of partial differential equations governing current distribution in the cable and we give the analytical solution of the general system. We then specialize the general solution to the particular case of uniform cable properties. In the particular case of a two-strand cable, we show that the analytical solution presented here is identical to the one already available in the literature. For a cable made of N equal strands we give a closed form solution that to our knowledge was never presented before. We finally validate the analytical solution by comparison to numerical results in the case of a step-like spatial distribution of the magnetic field over a short Rutherford cable, both in transient and steady ...

  4. External heating of electrical cables and auto-ignition investigation.

    Science.gov (United States)

    Courty, L; Garo, J P

    2017-01-05

    Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, David

    2012-12-31

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

  6. Cryogenic cooling system for HTS cable

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shigeru [Taiyo Nippon Sanso, Tsukuba (Japan)

    2017-06-15

    Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

  7. Horizon-T Experiment Calibrations - Cables

    CERN Document Server

    Beznosko, D; Iakovlev, A; Makhataeva, Z; Vildanova, M I; Yelshibekov, K; Zhukov, V V

    2016-01-01

    An innovative detector system called Horizon-T is constructed to study Extensive Air Showers (EAS) in the energy range above 1016 eV coming from a wide range of zenith angles (0o - 85o). The system is located at Tien Shan high-altitude Science Station of Lebedev Physical Institute of the Russian Academy of Sciences at approximately 3340 meters above the sea level. The detector consists of eight charged particle detection points separated by the distance up to one kilometer as well as optical detector to view the Vavilov-\\v{C}erenkov light from the EAS. Each detector connects to the Data Acquisition system via cables. The calibration of the time delay for each cable and the signal attenuation is provided in this article.

  8. Development of polymer packaging for power cable

    Directory of Open Access Journals (Sweden)

    S. Sremac

    2014-10-01

    Full Text Available This paper discusses the issues of product design and the procedure of developing polymer packaging as one of the most important engineering tasks. For the purpose of packing power cables a polymer packaging has been designed in the form of drum. Packaging and many other consumer products are largely produced using polymeric materials due to many positive features. High Density Polyethylene is the type of polyethylene proposed for packaging purposes due to its low degree of branching and strong intermolecular forces. Transport and storage processes were automated based on the radio-frequency identification technology. The proposed system is flexible in terms of its possibility of accepting and processing different types of cables and other products.

  9. Influence of Icing on Bridge Cable Aerodynamics

    DEFF Research Database (Denmark)

    Koss, Holger; Frej Henningsen, Jesper; Olsen, Idar

    2013-01-01

    In recent years the relevance of ice accretion for wind-induced vibration of structural bridge cables has been recognised and became a subject of research in bridge engineering. Full-scale monitoring and observation indicate that light precipitation at moderate low temperatures between zero and -...... forces of different bridge cables types. The experiments were conducted in a wind tunnel facility capable amongst others to simulate incloud icing conditions........ The determination of these force coefficients require a proper simulation of the ice layer occurring under the specific climatic conditions, favouring real ice accretion over simplified artificial reproduction. The work presented in this paper was performed to study the influence of ice accretion on the aerodynamic...

  10. Optical fiber cable chemical stripping fixture

    Science.gov (United States)

    Kolasinski, John R. (Inventor); Coleman, Alexander M. (Inventor)

    1995-01-01

    An elongated fixture handle member is connected to a fixture body member with both members having interconnecting longitudinal central axial bores for the passage of an optical cable therethrough. The axial bore of the fixture body member, however, terminates in a shoulder stop for the outer end of a jacket of the optical cable covering both an optical fiber and a coating therefor, with an axial bore of reduced diameter continuing from the shoulder stop forward for a predetermined desired length to the outer end of the fixture body member. A subsequent insertion of the fixture body member including the above optical fiber elements into a chemical stripping solution results in a softening of the exposed external coating thereat which permits easy removal thereof from the optical fiber while leaving a desired length coated fiber intact within the fixture body member.

  11. Occupational Asthma in a Cable Manufacturing Company

    Science.gov (United States)

    Attarchi, Mirsaeed; Dehghan, Faezeh; Yazdanparast, Taraneh; Mohammadi, Saber; Golchin, Mahdie; Sadeghi, Zargham; Moafi, Masoud; Seyed Mehdi, Seyed Mohammad

    2014-01-01

    Background: During the past decade, incidence of asthma has increased, which might have been due to environmental exposures. Objectives: Considering the expansion of cable manufacturing industry in Iran, the present study was conducted to evaluate the prevalence of occupational asthma in a cable manufacturing company in Iran as well as its related factors. Patients and Methods: This study was conducted on employees of a cable manufacturing company in Yazd, Iran, in 2012. The workers were divided into two groups of exposure (to toluene diisocyanate, polyvinyl chloride, polyethylene or polypropylene) and without exposure. Diagnosis of occupational asthma was made based on the subjects’ medical history, spirometry and peak flowmetry, and its frequency was compared between the two groups. Results: The overall prevalence of occupational asthma was 9.7%. This rate was 13.8% in the exposed group. Logistic regression analysis showed that even after adjustment for confounding factors, a significant correlation existed between the frequency of occupational asthma and exposure to the produced dust particles (P < 0.05). In addition, age, work experience, body mass index, cigarette smoking and shift work had significant correlations with the prevalence of occupational asthma (P < 0.05). Conclusions: Considering the high prevalence of occupational asthma among cable manufacturing company workers in Iran, this issue needs to be addressed immediately in addition to reduction of exposure among subjects. Reduction in work shift duration, implementation of tobacco control and cessation programs for the personnel, and performing spirometry tests and respiratory examinations in shorter periods may be among effective measures for reducing the incidence of occupational asthma in this industry. PMID:25558389

  12. A Flexible Recommendation System for Cable TV

    OpenAIRE

    Goncalves, Diogo; Costa, Miguel; Couto, Francisco M.

    2016-01-01

    Recommendation systems are being explored by Cable TV operators to improve user satisfaction with services, such as Live TV and Video on Demand (VOD) services. More recently, Catch-up TV has been introduced, allowing users to watch recent broadcast content whenever they want to. These services give users a large set of options from which they can choose from, creating an information overflow problem. Thus, recommendation systems arise as essential tools to solve this problem by helping users ...

  13. History of cable-stayed bridges

    DEFF Research Database (Denmark)

    Gimsing, Niels Jørgen

    1999-01-01

    The principle of supporting a bridge deck by inclined tension members leading to towers on either side of the span has been known for centuries. However, the real development of cable-stayed bridges did not begin before the 1950s. Since then the free span has been increased from 183 m...... in the Strömsund Bridge (from 1955) to 890 m in the Tatara Bridge (from 1999)....

  14. Optical fibre cable selection for electricity utilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The report provides an assessment of the range of optical fibre cable solutions available, by type e.g. OPGW, ADSS, rather than by design. it also examines the key issues which will influence an electricity utilities decisions and proposes a method of evaluating the options to identify the one which most closely matches the utility's critical needs, with measurements against time, cost and quality targets. (author)

  15. Localization of troubles in telephone cable networks

    Energy Technology Data Exchange (ETDEWEB)

    Chuxin Chen; Hollidge, T.L.; Sharma, D.D. [Pacific Bell, San Ramon, CA (United States)

    1996-12-31

    This paper describes an intelligent system which detects the location of troubles in a local telephone cable network. Such a task is very challenging, tedious, and requires human experts with years of experience and high analytical skills. Our system captures the expertise and knowledge required for this task, along with automated access to database systems, so that the system can help a human analyst to pin-point network trouble location more efficiently and accurately, ultimately reducing the cost of maintenance and repair. The system utilizes probabilistic reasoning techniques and logical operators to determine which plant component has the highest failure probability. This is achieved by building a topology of the local cable network, constructing a causal net which contains belief of failure for each plant component, given their current status, history data, cable pair distribution, and connectivity to other components. The Trouble Localization (TL) Module described in this paper is a crucial part of a larger system: Outside Plant Analysis System (OPAS) which has been deployed Statewide for over nine months at Pacific Bell PMAC centers. The TL system module utilizes AI and Object-Oriented technology. It is implemented in C++ on Unix workstations, and its graphical user interface is in an X Window environment.

  16. AC Losses of Prototype HTS Transmission Cables

    Energy Technology Data Exchange (ETDEWEB)

    Demko, J.A.; Dresner, L.; Hughey, R.L.; Lue, J.W.; Olsen, S.K.; Sinha, U.; Tolbert, J.C.

    1998-09-13

    Since 1995 Southwire Company and Oak Ridge National Laboratory (ORNL) have jointly designed, built, and tested nine, l-m long, high temperature superconducting (HTS) transmission cable prototypes. This paper summarizes the AC loss measurements of five of the cables not reported elsewhere, and compares the losses with each other and with theory developed by Dresner. Losses were measured with both a calorimetric and an electrical technique. Because of the broad resistive transition of the HTS tapes, the cables can be operated stably beyond their critical currents. The AC losses were measured in this region as well as below critical currents. Dresner's theory takes into account the broad resistive transition of the HTS tapes and calculates the AC losses both below and above the critical current. The two sets of AC 10SS data agree with each other and with the theory quite welL In particular, at low currents of incomplete penetration, the loss data agree with the theoretical prediction of hysteresis loss based on only the outer two Iayers carrying the total current.

  17. Cable energy function of cortical axons.

    Science.gov (United States)

    Ju, Huiwen; Hines, Michael L; Yu, Yuguo

    2016-01-01

    Accurate estimation of action potential (AP)-related metabolic cost is essential for understanding energetic constraints on brain connections and signaling processes. Most previous energy estimates of the AP were obtained using the Na(+)-counting method, which seriously limits accurate assessment of metabolic cost of ionic currents that underlie AP conduction along the axon. Here, we first derive a full cable energy function for cortical axons based on classic Hodgkin-Huxley (HH) neuronal equations and then apply the cable energy function to precisely estimate the energy consumption of AP conduction along axons with different geometric shapes. Our analytical approach predicts an inhomogeneous distribution of metabolic cost along an axon with either uniformly or nonuniformly distributed ion channels. The results show that the Na(+)-counting method severely underestimates energy cost in the cable model by 20-70%. AP propagation along axons that differ in length may require over 15% more energy per unit of axon area than that required by a point model. However, actual energy cost can vary greatly depending on axonal branching complexity, ion channel density distributions, and AP conduction states. We also infer that the metabolic rate (i.e. energy consumption rate) of cortical axonal branches as a function of spatial volume exhibits a 3/4 power law relationship.

  18. Dynamic behaviors of pretensioned cable AERORail structure

    Institute of Scientific and Technical Information of China (English)

    李方元; 吴培峰

    2015-01-01

    The AERORail, a new aerial transport platform, was chosen as the object of this work. Following a review of the literature on static behaviors, model tests on the basic dynamic mechanical characteristics were conducted. A series of 90 tests were completed with different factors, including tension force, vehicle load and vehicle speed. With regard to the proper tension and vehicle load, at a certain speed range, the tension increments of the rail’s cable were proved relatively small. It can be assumed that the change of tension is small and can be reasonably ignored when the tension of an entire span is under a dynamic load. When the tension reaches a certain range, the calculation of the cable track structure using classical cable theory is acceptable. The tests prove that the average maximum dynamic amplification factor of the deflection is small, generally no more than 1.2. However, when the vehicle speed reaches a certain value, the amplified factor will reach 2.0. If the moving loads increase, the dynamic amplification factor of dynamic deflection will also increase. The tension will change the rigidity of the structure and the vibration frequency; furthermore, the resonance speed will change at a certain tension. The vibration is noticeable when vehicles pass through at the resonance speed, and this negative impact on driving comfort requires the right velocity to avoid the resonance. The results demonstrate that more design details are required for the AERORail structure.

  19. An Optimization Model for Fiber-Optic Cable Installation Aboard Naval Vessels

    Science.gov (United States)

    2013-06-01

    of the most impressive components of Site B’s cable installation process was their real time tracking system. When a cable arrives at the shipyard...This is important because fiber-optic cables can be run in the same wireways or trays as heavier power cable (Cables Plus USA). 2. Specification Value

  20. Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator

    Science.gov (United States)

    Moses, Matthew S.; Murphy, Ryan J.; Kutzer, Michael D. M.; Armand, Mehran

    2016-01-01

    This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy.

  1. Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator.

    Science.gov (United States)

    Moses, Matthew S; Murphy, Ryan J; Kutzer, Michael D M; Armand, Mehran

    2015-12-01

    This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy.

  2. Rapid Optimization of Tension Distribution for Cable-Driven Parallel Manipulators with Redundant Cables

    Institute of Scientific and Technical Information of China (English)

    OUYANG Bo; SHANG Weiwei

    2016-01-01

    The solution of tension distributions is infinite for cable-driven parallel manipulators(CDPMs) with redundant cables. A rapid optimization method for determining the optimal tension distribution is presented. The new optimization method is primarily based on the geometry properties of a polyhedron and convex analysis. The computational efficiency of the optimization method is improved by the designed projection algorithm, and a fast algorithm is proposed to determine which two of the lines are intersected at the optimal point. Moreover, a method for avoiding the operating point on the lower tension limit is developed. Simulation experiments are implemented on a six degree-of-freedom(6-DOF) CDPM with eight cables, and the results indicate that the new method is one order of magnitude faster than the standard simplex method.The optimal distribution of tension distribution is thus rapidly established on real-time by the proposed method.

  3. Semiactive variable stiffness control for parametric vibration of cables

    Institute of Scientific and Technical Information of China (English)

    Li Hui; Chen Wenli; Ou Jinping

    2006-01-01

    In this paper, a semiactive variable stiffness (SVS) device is used to decrease cable oscillations caused by parametric excitation, and the equation of motion of the parametric vibration of the cable with this SVS device is presented.The ON/OFF control algorithm is used to operate the SVS control device. The vibration response of the cable with the SVS device is numerically studied for a variety of additional stiffness combinations in both the frequency and time domains and for both parametric and classical resonance vibration conditions. The numerical studies further consider the cable sag effect.From the numerical results, it is shown that the SVS device effectively suppresses the cable resonance vibration response, and as the stiffness of the device increases, the device achieves greater suppression of vibration. Moreover, it was shown that the SVS device increases the critical axial displacement of the excitation under cable parametric vibration conditions.

  4. Guy cable design and damping for vertical axis wind turbines

    Science.gov (United States)

    Carne, T. G.

    1981-01-01

    Guy cables are frequently used to support vertical axis wind turbines since guying the turbine reduces some of the structural requirements on the tower. The guys must be designed to provide both the required strength and the required stiffness at the top of the turbine. The axial load which the guys apply to the tower, bearings, and foundations is an undesirable consequence of using guys to support the turbine. Limiting the axial load so that it does not significantly affect the cost of the turbine is an important objective of the cable design. The lateral vibrations of the cables is another feature of the cable design which needs to be considered. These aspects of the cable design are discussed, and a technique for damping cable vibrations was mathematically analyzed and demonstrated with experimental data.

  5. Antenna mechanism of length control of actin cables

    CERN Document Server

    Mohapatra, Lishibanya; Kondev, Jane

    2014-01-01

    Actin cables are linear cytoskeletal structures that serve as tracks for myosin-based intracellular transport of vesicles and organelles in both yeast and mammalian cells. In a yeast cell undergoing budding, cables are in constant dynamic turnover yet some cables grow from the bud neck toward the back of the mother cell until their length roughly equals the diameter of the mother cell. This raises the question: how is the length of these cables controlled? Here we describe a novel molecular mechanism for cable length control inspired by recent experimental observations in cells. This antenna mechanism involves three key proteins: formins, which polymerize actin, Smy1 proteins, which bind formins and inhibit actin polymerization, and myosin motors, which deliver Smy1 to formins, leading to a length-dependent actin polymerization rate. We compute the probability distribution of cable lengths as a function of several experimentally tuneable parameters such as the formin-binding affinity of Smy1 and the concentra...

  6. Design, processing, and properties of Bi 2212\\/Ag Rutherford cables

    CERN Document Server

    Collings, E W; Scanlan, R M; Dietderich, D R; Motowidlo, L R; Sokolowski, R S; Aoki, Y; Hasegawa, T

    1999-01-01

    In a program intended to explore the use of high temperature superconducting (HTSC) cables in high field synchrotron dipole magnets model Bi:2212/Ag Rutherford cables were designed bearing in mind the needs for mechanical integrity, relatively high tensile strength, and low coupling losses. To satisfy these needs a core-type cable design was selected and a readily available heat-resistant core material acquired. Cables were wound for critical current- and AC loss measurement. Both winding-induced (mechanical) and core-induced (chemical) critical current degradation was examined. Interstrand coupling loss was measured calorimetrically on model cable samples with bare- and oxide-coated cores. From the results it was predicted that the losses of full-scale Bi:2212/Ag-wound LHC-type Rutherford cables would fall close to the acceptability range for the windings of high-field accelerator dipoles. (10 refs).

  7. Optical Fiber Grating Sensor for Force Measurement of Anchor Cable

    Institute of Scientific and Technical Information of China (English)

    JIANG Desheng; FU Jinghua; LIU Shengchun; SUI Lingfeng; FU Rong

    2006-01-01

    The development of the sensor suitable for measuring large load stress to the anchor cable becomes an important task in bridge construction and maintenance. Therefore, a new type of optical fiber sensor was developed in the laboratory - optical fiber grating sensor for force measurement of anchor cable (OFBFMAC). No similar report about this kind of sensor has been found up to now in China and other countries. This sensor is proved to be an effective way of monitoring in processes of anchor cable installation, cable cutting, cable force regulation, etc, with the accurate and repeatable measuring results. Its successful application in the tie bar cable force safety monitoring for Wuhan Qingchuan bridge is a new exploration of optical fiber grating sensing technology in bridge tie bar monitoring system.

  8. Study on the Configuration of Towed Flexible Cables

    Institute of Scientific and Technical Information of China (English)

    陈敏康; 张仁颐

    2003-01-01

    Based on the fundamental equation of flexible cable dynamics for a towed system, an easily solved mathematical model is set up in this paper by means of appropriate simplification. Several regular patterns of spatial motion of towed flexible cables in water are obtained through numerical simulation with the finite difference method, and then modification and verification by trial results at sea. A technical support is provided for the towing ship to maneuver properly when a flexible cable is towed. Furthermore, the relations between two towed flexible cables, which are towed simultaneously by a ship, are investigated. The results show that the ship towing two flexible cables is safe under the suggested arrangement of two winches for the towing system, and the coiling/uncoiling sequences of the cables as well as the suggested way of maneuvering.

  9. The Coupling Effect of Spatial Reticulated Shell Structure with Cables

    Institute of Scientific and Technical Information of China (English)

    MA Jun; ZHOU Dai; FU Xu-chen

    2005-01-01

    The spatial reticulated shell structure with cables (RSC) is a kind of coupling working system, which consists of flexible cables, reticulated shell structure (RS) and tower columns. The dynamic analysis of RSC based on the coupling model was carried out. Three kinds of elements such as the spatial bar element, cable element and beam element were introduced to analyze the reticulated shell, cable and tower column respectively. Furthermore,such parameter influences as structural boundary conditions, grid configuration, the span-to-depth ratio and the arrangement of cable system upon structural dynamics were analyzed. The structural vibration modes can be divided into four groups based on some numerical examples. And the frequencies in the same group are very close while the frequencies in different groups are different from each other obviously. It is clear that the sequence of the appearance of the each mode group heavily depends on the comparative stiffness of the tower column system, RS and cables.

  10. Total Magnetic Field Signatures over Submarine HVDC Power Cables

    Science.gov (United States)

    Johnson, R. M.; Tchernychev, M.; Johnston, J. M.; Tryggestad, J.

    2013-12-01

    Mikhail Tchernychev, Geometrics, Inc. Ross Johnson, Geometrics, Inc. Jeff Johnston, Geometrics, Inc. High Voltage Direct Current (HVDC) technology is widely used to transmit electrical power over considerable distances using submarine cables. The most commonly known examples are the HVDC cable between Italy and Greece (160 km), Victoria-Tasmania (300 km), New Jersey - Long Island (82 km) and the Transbay cable (Pittsburg, California - San-Francisco). These cables are inspected periodically and their location and burial depth verified. This inspection applies to live and idle cables; in particular a survey company could be required to locate pieces of a dead cable for subsequent removal from the sea floor. Most HVDC cables produce a constant magnetic field; therefore one of the possible survey tools would be Marine Total Field Magnetometer. We present mathematical expressions of the expected magnetic fields and compare them with fields observed during actual surveys. We also compare these anomalies fields with magnetic fields produced by other long objects, such as submarine pipelines The data processing techniques are discussed. There include the use of Analytic Signal and direct modeling of Total Magnetic Field. The Analytic Signal analysis can be adapted using ground truth where available, but the total field allows better discrimination of the cable parameters, in particular to distinguish between live and idle cable. Use of a Transverse Gradiometer (TVG) allows for easy discrimination between cable and pipe line objects. Considerable magnetic gradient is present in the case of a pipeline whereas there is less gradient for the DC power cable. Thus the TVG is used to validate assumptions made during the data interpretation process. Data obtained during the TVG surveys suggest that the magnetic field of a live HVDC cable is described by an expression for two infinite long wires carrying current in opposite directions.

  11. China’s Aluminum Alloy Cable Market has Taken Shape

    Institute of Scientific and Technical Information of China (English)

    2014-01-01

    <正>Aluminum alloy cable is a mature product and technology that has been used for nearly fifty years in the U.S.Through six years’promotion,it has been widely recognized and accepted in the China market since 2013,which laid the foundation for the development of the aluminum alloy cable market.Aluminum alloy cable is widely applied in the fields of civil construction and industrial and mining enterprises,especially in real estate,steel and metallurgy.

  12. 77 FR 61351 - Cable Television Technical and Operational Requirements

    Science.gov (United States)

    2012-10-09

    ...In this document, the Federal Communications Commission proposes to update technical and operational rules related to cable television systems and other multichannel video programming distributors that operate coaxial cable systems. The Commission seeks comments on rules that would update its minimum signal quality standards and signal leakage detection and monitoring for digital transmission. Additionally, the Commission proposes numerous corrections and updates to its to its cable television technical rules.

  13. DEMAND PULL AND SUPPLY PUSH IN PORTUGUESE CABLE TELEVISION

    OpenAIRE

    João Leitão

    2004-01-01

    In this paper a Vector Autoregressive Model is applied to the most representative Portuguese cable television operators, in order to obtain a dynamic analysis of the interactivity established between the supply and the demand of network services, through the strategy of vertical integration of services. The results reveal the existence of two driving forces in the Portuguese main cable networks, on the one hand, the supply push which contributes to the enhancement of the basic cable demand, a...

  14. Service Life Estimation Technique of Oxidized XLPE Cables

    Science.gov (United States)

    Hatanaka, Masaki; Nakade, Masahiko; Hirose, Takafumi; Sugimoto, Syuu; Namiki, Yukihiko

    XLPE which is the insulator of the XLPE cable will be oxidized by heat. But, an accident caused by oxidized XLPE has hardly reported until now. Therefore, oxidization of XLPE hasn’t been regard as important. But recently we found that XLPE cable used for a long time could break down due to the oxidization of XLPE by simulation result. So, we developed the service life estimation technique of oxidized XLPE cables used FT-IR.

  15. BEHAVIOR OF ELASTIC TOWING CABLES IN SHEAR CURRENTS

    Institute of Scientific and Technical Information of China (English)

    HOU Guo-xiang; LI Hong-bin; ZHANG Sheng-jun; YANG Yun-tao; XU Shi-hua; XIE Wei

    2005-01-01

    The formulation and solution of governing equations that can be used to analyse the three-dimensional behaviour of elastic towing cables subjected to arbitrary sheared currents were presented in this paper. The elastic cable geometry was described in terms of two angles, elevation and azimuth, which are related to Cartesian co-ordinates by geometry compatibility relations. These relations were combined with the cable equilibrium equations to obtain a system of non-linear differential equations. In the end, results for cable tension, angles, geometry and elongation are presented for example cases.

  16. Generalized cable theory for neurons in complex and heterogeneous media.

    Science.gov (United States)

    Bédard, Claude; Destexhe, Alain

    2013-08-01

    Cable theory has been developed over the last decade, usually assuming that the extracellular space around membranes is a perfect resistor. However, extracellular media may display more complex electrical properties due to various phenomena, such as polarization, ionic diffusion, or capacitive effects, but their impact on cable properties is not known. In this paper, we generalize cable theory for membranes embedded in arbitrarily complex extracellular media. We outline the generalized cable equations, then consider specific cases. The simplest case is a resistive medium, in which case the equations recover the traditional cable equations. We show that for more complex media, for example, in the presence of ionic diffusion, the impact on cable properties such as voltage attenuation can be significant. We illustrate this numerically, always by comparing the generalized cable to the traditional cable. We conclude that the nature of intracellular and extracellular media may have a strong influence on cable filtering as well as on the passive integrative properties of neurons.

  17. Utility of polymer cerclage cables in revision shoulder arthroplasty.

    Science.gov (United States)

    Edwards, T Bradley; Stuart, Kyle D; Trappey, George J; O'Connor, Daniel P; Sarin, Vineet K

    2011-04-11

    Revision shoulder arthroplasty often requires humeral osteotomy for stem extraction or is complicated by periprosthetic fracture. In these situations, various modes of fixation are used, including cerclage wires, cable plates, and allograft strut augmentation. The use of metal wires and cables, however, has been associated with soft tissue irritation, sharps injuries, and accelerated wear of joint arthroplasty bearing surfaces. As an alternative to traditional metal cables, the SuperCable (Kinamed Inc, Camarillo, California) contains braided ultra-high molecular-weight polyethylene fibers surrounding a nylon core. To date, no studies have examined the use of nonmetallic cerclage cables in shoulder arthroplasty.A retrospective review was performed of 11 patients who underwent shoulder arthroplasty for which nonmetallic cerclage cables were used. Clinical and radiographic data were examined regarding patient age, procedure performed, indication for cerclage cabling, time to healing of osteotomy or fracture, and any complications associated with the use of these cerclage cables. Minimum follow-up was 1 year. Ten patients underwent reverse total shoulder arthroplasty, and 1 patient underwent revision unconstrained total shoulder arthroplasty. Mean follow-up was 20.5 months. Ten patients required humeral osteotomy for stem or cement removal. Allograft augmentation was performed in 7 patients. Mean time to healing was 3.2 months. No patients experienced loosening or migration of hardware or allograft, and no complications directly related to the use of nonmetallic cerclage cables were identified. Copyright 2011, SLACK Incorporated.

  18. Strand critical current degradation in $Nb_{3}$ Sn Rutherford cables

    CERN Document Server

    Barzi, E; Higley, H C; Scanlan, R M; Yamada, R; Zlobin, A V

    2001-01-01

    Fermilab is developing 11 Tesla superconducting accelerator magnets based on Nb/sub 3/Sn superconductor. Multifilamentary Nb/sub 3/Sn strands produced using the modified jelly roll, internal tin, and powder-in-tube technologies were used for the development and test of the prototype cable. To optimize the cable geometry with respect to the critical current, short samples of Rutherford cable with packing factors in the 85 to 95% range were fabricated and studied. In this paper, the results of measurements of critical current, n-value and RRR made on the round virgin strands and on the strands extracted from the cable samples are presented. (5 refs).

  19. Current distribution among layers of single phase HTS cable conductor

    Science.gov (United States)

    Zheng, Y. B.; Wang, Y. S.; Pi, W.; Ju, P.; Wang, Y. S.

    2014-12-01

    High temperature superconducting (HTS) power cable shows high application prospect in modern power transmission, as it is superior over conventional transmission lines in high engineering current density and environmental friendliness. Its configuration is generally composed of several HTS layers designed with the principle of uniform current distribution, but there are few experimental results to verify the distribution. In this paper, a HTS cable model was designed based on the principle of uniform current, and the current distributions among layers in an HTS cable model were measured by Rogowski coils. The results provide an important basis for design of multi-layer HTS cable.

  20. Analysis of tensioned membrane structures considering cable sliding

    Institute of Scientific and Technical Information of China (English)

    宋昌永

    2003-01-01

    In routine design of tensioned membrane st ructures, the membrane is gen erally modeled using space membrane elements and the cables by space cable eleme nts, with no sliding allowed between the membrane and the cables. On the other h and, large deflections are expected and sliding between the membrane and the cab les is inevitable. In the present paper, the general finite element code ABAQUS was employed to investigate the influence of cable sliding on membrane surface o n the structural behavior. Three analysis models were devised to fulfill this pu rpose: (1) The membrane element shares nodes with the cable element; (2) The cab le can slide on the membrane surface freely (without friction) and (3) The cable can slide on the membrane surface, but with friction between the cable and the membrane. The sliding problem is modeled using a surface-based contact algorithm . The results from three analysis models are compared, showing that cable slidin g has only little influence on the structure shape and on the stress distributio ns in the membrane. The main influence of cable sliding may be its effect on the dynamic behavior of tensioned membrane structures.

  1. Development of scaling rules for Rutherford type superconducting cables

    Energy Technology Data Exchange (ETDEWEB)

    Royet, J.M.; Scanlan, R.M.

    1990-09-01

    During the R D phase of the Superconducting Supercollider (SSC) program, LBL was responsible for establishing the parameters for cables used in SSC dipole and quadrupole magnets. In addition, the design and fabrication of a new cable for use in the Low Beta Quadrupoles. As a result of the development work on these and other cables, we have arrived a set of scaling rules which provide guidelines for choosing the parameters for a wide range of superconducting cables. These parameters include strand size, strand number, keystone angle, percent compaction, cable pitch and compacted cable dimensions. In addition, we have defined the tolerance ranges for the key cable manufacturing parameters such as mandrel size and shape, stand tension, and Turkshead temperature control. In this paper, we present the results on cables ranging from 8 strands to 36 strands of 0.65mm wire and from 8 strands to 30 strands of 0.8mm wire. We use these results to demonstrate the application of the scaling rules for Rutherford-type cable.

  2. Non-destructive control applied on power station cables: assessment of the residual mechanical properties of cables; Controle non-destructif applique aux cables centrales: determination des caracteristiques mecaniques residuelles des cables

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, Y.; Pinel, B.; Brincourt, T.

    1996-12-31

    Cables in power plants are subjected to thermal and radiation stresses. As a result, these equipments have their electrical and mechanical properties modified versus time. In order to follow mechanical characteristics on site, we have tested a non destructive equipment named `INDENTER`. The experiments have been conducted on L.O.C.A. cables (EPR-CSPE) and PVC. Results obtained are satisfying for L.O.C.A. cables. For PVC cables, supplementary tests might be done in order to pronounce opinion in the interest of this equipment. we have observed chose relation between modulus INDENTER and classical mechanical data (absolute elongation at break). (authors).

  3. A new approach to underground cable performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Al-Saud, M.S.; El-Kady, M.A.; Findlay, R.D. [Department of Electrical and Computer Engineering, McMaster University, Hamilton, Ontario L8S 4K1 (Canada)

    2008-05-15

    This paper presents a new approach to thermal field sensitivities and ampacity computations of underground power cables using a proposed algorithm of perturbed finite-element analysis. The new approach involves the use of derived sensitivity coefficients associated with various cable parameters of interest, and use these coefficients to achieve optimal cable performance. The proposed model provides a quick methodology, based on the finite-element model, to assess the cable thermal performance subject to variations in the cable thermal circuit parameters. The developed algorithm was applied to various practical cable systems. The effect of multilayered thermal conductivities and boundary parameters variations on the actual cable system ampacity was investigated using the proposed methodology. A comparison was made of the obtained results with the conventional finite-element approach in order to show the applicability and usefulness of the developed methodology. Our objective was to assess the effects of operating parameter variations in a straightforward manner, without repeating the thermal field analysis for each parameter change. The thermal field of an underground power cable sample directly buried in the soil was measured in the laboratory using a developed full-size experimental setup. The investigations involve all parts of the thermal circuit parameters representing cable composition, surrounding soil and boundary phenomena. The experimental setup was used to validate the simulation model by comparing the simulation results with the real laboratory measurements. Such experimental verification confirmed the accuracy of the new introduced finite-element sensitivity methodology. (author)

  4. Development of superconducting transmission cable. CRADA final report

    Energy Technology Data Exchange (ETDEWEB)

    Hawsey, R.; Stovall, J.P. [Oak Ridge National Lab., TN (United States); Hughey, R.L.; Sinha, U.K. [Southwire Co., Carrollton, GA (United States)

    1997-10-01

    The purpose of this Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and Southwire Company is to develop the technology necessary to proceed to commercialization of high-temperature superconducting (HTS) transmission cables. Power transmission cables are a promising near-term electric utility application for high-temperature superconductivity. Present HTS wires match the needs for a three-phase transmission cable: (1) the wires must conduct high currents in self-field, (2) there are no high forces developed, and (3) the cables may operate at relatively low current density. The commercially-available HTS wires, in 100-m lengths, make construction of a full three-phase, alternating current (ac) transmission cable possible. If completed through the pre-commercialization phase, this project will result in a new capability for electric power companies. The superconducting cable will enable delivery with greater efficiency, higher power density, and lower costs than many alternatives now on the market. Job creation in the US is expected as US manufacturers supply transmission cables to the expanding markets in Asia and to the densely populated European cities where pipe-type cable is prevalent. Finally, superconducting cables may enable delivery of the new, diverse and distributed sources of electricity that will constitute the majority of new installed electrical generation in the world during the coming decades.

  5. Modeling and Experiments of Spray System for Cable Painting Robot

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jia-liang; Lü Tian-sheng; LI Bei-zhi

    2008-01-01

    Many cable-stayed bridges have been built in the world in the past decades,and cable-stayed structures have been adopted in many large constructions.The cable painting robot is safe and economically efficient for stay cable maintenance.In order to satisfy the need for spraying cables in hiigh attitude,an automatic cable spray system for cable painting robots is presented in this paper.Using the βdistribution,paint thickness distribution on a cylinder surface is modeled.The spray gun's number,angle and movement are analyzed to get coat evenness.Then a robotic spray system engineering prototype has been developed,which includes a cable electric running climbing base,a spray cover,four airless spray guns and a pressurized paint container.Experiments indicate that four airless spray guns can guarantee good coat quality for general stay cables.The field tests have been successfully conducted on Nanpu Bridge,Shanghai.

  6. VLF Tan Delta Measurement for Used XLPE Power Cables

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Woo Sang; Ha, Che Wung; Joo, Kwang Ho [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2011-05-15

    Medium voltage power cables in nuclear power plants are currently managed through the visual inspection or by monitoring environmental factors such as the temperature and radiation levels. However, these methods are insufficient to monitor aging degradation of power cables. The NRC requires an additional monitoring program to detect the aged degradation, especially for safety-related power cables which are inaccessible or installed underground. EPRI suggested that very low frequency (VLF) tan {delta} test be included in MV power cable diagnostic programs. In addition, the VLF tan {delta} test was recently adopted for domestic submarine distribution cable diagnostics. KEPRI suggested that the impacts of leakage current should be controlled in VLF tan {delta} test for the submarine cables. As a pre-process to develop such a program, tan {delta} tests have been performed for 4.16 kV cables which were removed from the domestic nuclear power plant after approximate 30 years of service to analyze the degradation of long time serviced cables and the effect of leakage current from the both ends of cables

  7. Payout tension control system for reel mounted cable

    Science.gov (United States)

    Winkler, Gerhard B.

    1992-06-01

    A payout control arm is angularly displaceable about a brake shaft during payout of a cable from a storage reel in response to tensioning forces transmitted through the cable from a payout load with the cable being entrained about a pulley rotatably carried on the control arm in spaced relation to the brake shaft. Gearing drivingly connects the pulley to the brake shaft to stop payout and cause the cable to frictionally grip the pulley in response to brake engagement thereby preventing continued transmittal of tensioning forces to the reel.

  8. Performances of super-long span prestressed cable-stayed bridge with CFRP cables and RPC girder

    Institute of Scientific and Technical Information of China (English)

    Fang Zhi; Fan Fenghong; Ren Liang

    2013-01-01

    To discuss the applicability of advanced composite carbon fiber reinforced polymer (CFRP) and ultra-high performance concrete reactive powder concrete (RPC) in super-long span cable-stayed bridges , taking a 1 008 m cable-stayed bridge with steel girders and steel cables as an example,a new cable-stayed bridge in the same span with RPC girders and CFRP cables was designed,in which the cable’s cross section was determined by the principle of equivalent cable capacity and the girder’s cross section was determined in virtual of its stiffness, shear capacity and local stability. Based on the methods of finite element analysis,the comparative analysis of these two cable-stayed bridge schemes about static performances,dynamic performances,stability and wind resis-tance behavior were carried out. The results showed that it was feasible to form a highly efficient,durable concrete cable-stayed bridge with RPC girders and CFRP cables and made its applicable span range expand to 1 000 m long around.

  9. NONLINEAR TRANSIENT RESPONSE OF STAY CABLE WITH VISCOELASTICITY DAMPER IN CABLE-STAYED BRIDGE

    Institute of Scientific and Technical Information of China (English)

    陈水生; 孙炳楠; 冯义卿

    2004-01-01

    Taking the bending stiffness,static sag,and geometric non-linearity into consideration,the space nonlinear vibration partial differential equations were derived.The partical differential equations were discretized in space by finite center difference approximation,then the nonlinear ordinal differential equations were obtained.A hybrid method involving the combination of the Newmark method and the pseudo-force strategy was proposed to analyze the nonlinear transient response of the inclined cable-dampers system subjected to arbitrary dynamic loading.As an example,two typical stay cables were calculated by the present method.The results reveal both the validity and the deficiency of the viscoelasticity damper for vibration control of stay cables.The efficiency and accuracy of the proposed method is also verified by comparing the results with those obtained by using Runge-Kutta direct integration technique.A new time history analysis method is provided for the research on the stay cable vibration control.

  10. The Cable Fable Revisited: Discourse, Policy, and the Making of Cable Television.

    Science.gov (United States)

    Streeter, Thomas

    1987-01-01

    Discusses how utopian talk about cable television as a dramatic new technology swept through the policy arena in the 1970s. Analyzes this talk as a discursive practice to demonstrate both the value of discourse analysis and some contradictions of the policy process. Shows how discourse thus helped shape an institution that it failed to describe.…

  11. Advances in cables and outside plant for cable television and optical fibre local networks

    Science.gov (United States)

    Bridle, Peter

    1986-11-01

    During 1985 Bristish Telecom commenced the installation of a number of cable television systems in the United Kingdom. One of these systems, in Westminster, London, is of the Switched Star type, developed by the British Telecom Research Laboratories. The network comprises optical fiber cable between the head-end and the cabinet-mounted switch, and coaxial cable between the switch and the customer. A number of new outside plant products have been developed to meet the special requirements of the Westminister installation. This earlier work, together with the experience gained from the installation of optical fibers in the British Telecom trunk and junction networks, formed an ideal basis for evolving the line plant necessary to enable BT to introduce singlemode optical fiber into the local network. A range of cables is being developed by UK companies, suitable for installing in the harsh environment of the local network. Joint organizers and flexibility nodes are being introduced, both for underground application and for within the exchange and customer's premises. In addition blown-fiber techniques are being used to introduce fiber into these networks.

  12. Energy cables: defects research and identification; Cables d'energie: recherche et identification de defauts

    Energy Technology Data Exchange (ETDEWEB)

    Kuzyk, H. [Electricite de France (EDF), 75 - Paris (France)

    2006-05-15

    This article presents the different types of power cables and their possible defects (external and internal). Then it describes the procedure used for defects detection and for the identification of the type of defect (measurement of the insulation resistance, dielectric test, continuity measurement). (J.S.)

  13. Fire induced damage to electrical cables and fire growth on cables

    Energy Technology Data Exchange (ETDEWEB)

    Keski-Rahkonen, O.; Mangs, J. [VTT Building and Transport (Finland); Bertrand, R. [IRSN (France); Roewekamp, M. [GRS (Germany)

    2002-07-01

    Cable fires are statistically significant initiators of high-risk developments in NPPs. Statistical, analytical, numerical simulation, as well as experimental work in three countries is reviewed. Despite fair progress some areas for new research are still found to be necessary. (orig.)

  14. Two-way cable television project

    Science.gov (United States)

    Wilkens, H.; Guenther, P.; Kiel, F.; Kraus, F.; Mahnkopf, P.; Schnee, R.

    1982-02-01

    The market demand for a multiuser computer system with interactive services was studied. Mean system work load at peak use hours was estimated and the complexity of dialog with a central computer was determined. Man machine communication by broadband cable television transmission, using digital techniques, was assumed. The end to end system is described. It is user friendly, able to handle 10,000 subscribers, and provides color television display. The central computer system architecture with remote audiovisual terminals is depicted and software is explained. Signal transmission requirements are dealt with. International availability of the test system, including sample programs, is indicated.

  15. Diagnostics and testing of high voltage cable systems

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, P.; Oyegoke, B.; Aro, M.

    2003-07-01

    Reliability demands on electricity generation and distribution are increasing. Power utilities have faced new challenges due to liberalisation of electricity markets, increasing authors regulation and new claims for compensation of unexpected power shut downs. As a result power utilities have to concentrate more on asset management to reduce costs, to postpone investments, to optimise technical management keeping at the same time reliability and power quality at high level. Nowadays it is important to do right things at right place at right time. Maintenance strategy is changing from predictive or repairing maintenance to the condition based maintenance (CBM). Success of CBM depends partly on how good and reliable tools are available to determine condition of electrical apparatus. Cables have been used in electricity distribution since beginning of 20th century. Oldest still in use cables in Finland has been installed late 1940's. Nowadays almost all new distribution systems in urban areas are done using cables. Wide variety of cables are in use. Knowledge of condition and history of cables is not so well documented. Professional skill to install cable systems is disappearing due to outsourcing of maintenance groups. There is a worry about increasing amount of after installation faults due to loosing of professional skills to install cable systems. Wide variety of cable insulation systems and large variety in ages of cables still in use will place hard challenges for cable condition assessment. Earlier studies showed that measurement of insulation resistance is almost only diagnostic measurement performed to cable systems. Knowledge and experience of new diagnostic method is not so widely distributed. Based on previous project, dielectric response (DR) measurement and partial discharge (PD) measurement seemed to be most promising tools for the condition assessment of cable systems. Increased moisture content in oil-paper insulated cable or water trees in

  16. Proposed Ordinance for the Regulation of Cable Television. Working Draft.

    Science.gov (United States)

    Chicago City Council, IL.

    A model ordinance is proposed for the regulation of cable television in the city of Chicago. It defines the language of the ordinance, sets forth the method of granting franchises, and describes the terms of the franchises. The duties of a commission to regulate cable television are listed and the method of selecting commission members is…

  17. LOW-LOSS CABLE AND METHOD OF FABRICATION

    Science.gov (United States)

    McCarthy, R.L. et al.

    1960-09-27

    A radiation-resistant coaxial electrical cable capable of carrying very small currents at high voltages with little leakage is described. The cable comprises an inner axial conductor separated from an outer coaxial tubular conductor by annular layer of fibrous silica insulation. The silica insulation is formed by leaching boron from spun horosilicate glass and then heat treating the silica at a high temperature.

  18. Comparison of several innovative bridge cable surface modifications

    DEFF Research Database (Denmark)

    Kleissl, Kenneth; Georgakis, Christos T.

    Over the last two decades, several bridge cable manufacturers have introduced surface modifications on the high-density polyethylene (HDPE) sheathing that is installed for the protection of inner cable strands or wires. The modifications are based on research undertaken predominantly in Europe an...

  19. 47 CFR 15.118 - Cable ready consumer electronics equipment.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Cable ready consumer electronics equipment. 15... Unintentional Radiators § 15.118 Cable ready consumer electronics equipment. (a) All consumer electronics TV... provisions of this section. Consumer electronics TV receiving equipment that includes features intended...

  20. A Coaxial Cable Fabry-Perot Interferometer for Sensing Applications

    Directory of Open Access Journals (Sweden)

    Ming Luo

    2013-11-01

    Full Text Available This paper reports a novel coaxial cable Fabry-Perot interferometer for sensing applications. The sensor is fabricated by drilling two holes half-way into a coaxial cable. The device physics was described. The temperature and strain responses of the sensor were tested. The measurement error was calculated and analyzed.

  1. Levitation of Superconductive Cable in Earth Magnetic Field

    Directory of Open Access Journals (Sweden)

    Bohus Ulrych

    2006-01-01

    Full Text Available The paper represents an introductory study about a superconductive cable levitating in Earth’s magnetic field. Built are two mathematical models of the problem providing both the shape of the arc of the cable and forces acting along it. The theoretical analysis is supplemented with an illustrative example.

  2. Problems of Automatic Test of Insulation in Cable Production

    Science.gov (United States)

    Red'ko, V. V.; Leonov, A. P.; Red'ko, L. A.; Bolgova, V. A.

    2016-01-01

    The article presents a qualitative and quantitative assessment of cable products insulation defects that can be reliably detected by means of the electrosparking control during the cable production process. The performance potential of technological control is evaluated: the limit of reliable detection of defective places in insulation taking into account the technical capabilities of modern control devices is marked.

  3. A method for calculating the productivity of cable communications networks

    Science.gov (United States)

    Shulikin, S. N.; Shulikina, M. S.; Maryin, S. S.; Vinogradova, D. V.; Zavgorodnyaya, M. E.

    2016-04-01

    A probabilistic-mathematical instrument was used to develop a method for calculating the productivity of a cable line. The effect of deviation of factors from data of recording devices was determined when identifying random stream characteristics. The developed method was used to perform predictive calculation of the productivity of the modern cable communication line.

  4. Study of High Voltage AC Underground Cable Systems

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Bak, Claus Leth; Wiechowski, Wojciech T.

    2010-01-01

    High-Voltage cables are starting to be more often used to transmit electric energy at high-voltage levels, introducing in the electric grid phenomena that are uncommon when using Overhead Lines. Under the phenomena worthy of special attention are those related with the cable energisation and deen...

  5. Chemical oxidation of cable insulating oil contaminated soil

    NARCIS (Netherlands)

    Jinlan Xu,; Pancras, T.; Grotenhuis, J.T.C.

    2011-01-01

    Leaking cable insulating oil is a common source of soil contamination of high-voltage underground electricity cables in many European countries. In situ remediation of these contaminations is very difficult, due to the nature of the contamination and the high concentrations present. Chemical oxidati

  6. Cable Television: A Summary Overview for Local Decisionmaking.

    Science.gov (United States)

    Baer, Walter S.

    Addressed to citizen groups, local government officials, and others concerned with the development of cable television in their communities, this report summarizes briefly some of the major issues surrounding local decisionmaking for cable television. This summary presents some of the more detailed information found in the companion publication,…

  7. A New Approach to Outreach Services: Cable Television.

    Science.gov (United States)

    Schenk, George E.; Wiscons, Bradley J.

    1984-01-01

    Describes the delivery of counseling center presentations to college students via cable television. Discusses the development of the first tape, which was on career development, and detailed other uses of videotapes. Future plans include use of cable television in health education and financial aid as well as career planning. (JAC)

  8. Cable Television and Education; A Report from the Field.

    Science.gov (United States)

    National Cable Television Association, Inc., Washington, DC.

    Cable television, with its potential wealth of channels, provides education with a possible new tool through which existing services can be improved and new services devised. This report very briefly describes some of the possibilities for the use of cable television and gives a number of examples of ways in which communities are using cable…

  9. Cable Television U. S. A. An Analysis of Government Policy.

    Science.gov (United States)

    Seiden, Martin H.

    It is the opinion of the author that the Federal Communications Commission (FCC) has wasted much of its time and energy in recent years constantly forming and revising cable television regulations when cable television is a relatively minor phenomenon with which the Commission should not have concerned itself in the first place. Thus, this book…

  10. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  11. Education and Cable TV: A Guide to Franchising and Utilization.

    Science.gov (United States)

    Shafer, Jon

    Designed to provide the educator with some answers about cable television (CATV), this monograph and resource catalog provides a basic description of CATV, its educational uses, and the franchising provisions which relate to its educational uses. The transition of CATV from an association with broadcast television toward cable information systems…

  12. A Critical Look At South Dakota Cable TV Franchising.

    Science.gov (United States)

    Williamson, Rick P.

    An examination of the present status and future potential of cable television (CATV) in South Dakota is conducted. Chapter 1 offers a brief introduction to cable in the State and Chapter 2 discusses the value of CATV to South Dakota. The next Chapter presents a State plan for communications and the fourth deals with the subject of franchising. The…

  13. Information Delivery Systems--The Alternative of Cable TV.

    Science.gov (United States)

    Bardwell, John

    Cable television offers great benefits in its large information carrying capacity, its local and selective character, and its two-way capability. A key fact in the history of cable television is that in 1971 the PCC required that one channel be reserved for educational use. Planning for the "wired city" has presented problems for both town…

  14. Experimental Investigation of Aerodynamic Instability of Iced Bridge Cable Sections

    DEFF Research Database (Denmark)

    Koss, Holger; Lund, Mia Schou Møller

    2013-01-01

    of bridge cables under wind action. This paper describes the experimental simulation of ice accretion on a real bridge cable sheet HDPE tube segment (diameter 160mm) and its effect on the aerodynamic load. Furthermore, aerodynamic instability will be estimated with quasi-steady theory using the determined...

  15. Development and testing of a 50 KA, pulsed superconducting cable

    Energy Technology Data Exchange (ETDEWEB)

    Wollan; DeClerc, J.; Hamilton, W.; Zeitlin, B.

    1983-05-01

    Prototype cables for 7.5 T, pulsed field application in tokamak poloidal field coils have been designed, fabricated, and evaluated. Successful fabrication of a 10 m superconducting sample represents the largest superconducting cable ever made. Details of the fabrication, the problems expected and encountered, and the solutions to those problems are discussed. Results of stability measurements on the superconducting prototype also are presented.

  16. The Offshore Wind Farm Array Cable Layout Problem

    DEFF Research Database (Denmark)

    Bauer, Joanna; Lysgaard, Jens

    2014-01-01

    In an offshore wind farm (OWF), the turbines are connected to a transformer by cable routes that cannot cross each other. Finding the minimum cost array cable layout thus amounts to a vehicle routing problem with the additional constraints that the routes must be embedded in the plane. For this p...

  17. Calculation Method for Normal Inducedlongitudinal Voltage on Pilot Cable

    Directory of Open Access Journals (Sweden)

    Abdelaziz B.M. Kamel,

    2014-09-01

    Full Text Available In this paper a full study and detailed calculations of the induced voltage in pilot cables are carried out. First an introduction showing the importance of the induced voltage and its effect in pilot cables. The first calculation method Flat Formation. The second calculation method Trefoil Formation. Then the results obtained for both methods and compared. Finally a conclusion is conduct.

  18. Modeling and simulation of HTS cables for scattering parameter analysis

    Science.gov (United States)

    Bang, Su Sik; Lee, Geon Seok; Kwon, Gu-Young; Lee, Yeong Ho; Chang, Seung Jin; Lee, Chun-Kwon; Sohn, Songho; Park, Kijun; Shin, Yong-June

    2016-11-01

    Most of modeling and simulation of high temperature superconducting (HTS) cables are inadequate for high frequency analysis since focus of the simulation's frequency is fundamental frequency of the power grid, which does not reflect transient characteristic. However, high frequency analysis is essential process to research the HTS cables transient for protection and diagnosis of the HTS cables. Thus, this paper proposes a new approach for modeling and simulation of HTS cables to derive the scattering parameter (S-parameter), an effective high frequency analysis, for transient wave propagation characteristics in high frequency range. The parameters sweeping method is used to validate the simulation results to the measured data given by a network analyzer (NA). This paper also presents the effects of the cable-to-NA connector in order to minimize the error between the simulated and the measured data under ambient and superconductive conditions. Based on the proposed modeling and simulation technique, S-parameters of long-distance HTS cables can be accurately derived in wide range of frequency. The results of proposed modeling and simulation can yield the characteristics of the HTS cables and will contribute to analyze the HTS cables.

  19. Testing of an HTS Power Cable Made from YBCO Tapes

    Energy Technology Data Exchange (ETDEWEB)

    Gouge, Michael J [ORNL; Duckworth, Robert C [ORNL; Demko, Jonathan A [ORNL; Rey, Christopher M [ORNL; Lindsay, David T [ORNL; Roden, Mark L [ORNL; Tolbert, Jerry Carlton [ORNL

    2007-01-01

    Oak Ridge National Laboratory (ORNL) has designed, built, and tested a 1.25-m-long, prototype high temperature superconducting (HTS) power cable made from second-generation YBa2Cu3Ox (YBCO)-coated conductor tapes. Electrical tests of this cable were performed in liquid nitrogen at 77 K. DC testing of the HTS cable included determination of the V-I curve with a critical current of about 2100 A, which was consistent with the critical currents of the two layers of 4.4-mm wide YBCO tapes. AC testing of the cable was conducted at currents up to about 1500 Arms. The ac losses were determined calorimetrically by measuring the response of a calibrated temperature sensor placed on the former and electrically by use of a Rogowski coil with a lock-in amplifier. Over-current testing was conducted at peak current values up to 4.9 kA for pulse lengths of 0.3-0.5 s. Test results are compared to earlier data from a 1.25-m-long power cable made from 1-cm-wide YBCO tapes and also comparable BSCCO cables. This commercial-grade HTS cable demonstrated the feasibility of second-generation YBCO tapes in an ac cable application.

  20. 76 FR 72982 - Cable Statutory License: Specialty Station List; Correction

    Science.gov (United States)

    2011-11-28

    ... the Federal Register on November 8, 2011 at 76 FR 69288: On page 69289, WNYA-CA, Albany, NY was... Copyright Office Cable Statutory License: Specialty Station List; Correction AGENCY: Copyright Office... use of the cable compulsory license. In response to the publication of an initial list of...

  1. Coupling currents in Rutherford cables under time varying conditions

    NARCIS (Netherlands)

    Verweij, A.P.; Kate, ten H.H.J.

    1993-01-01

    A network model is presented to simulate fully transposed Rutherford cables under time varying conditions. The intrinsic properties of the cable and the external applied conditions can be changed spatially. Several statistical distributions of the contact resistances are built in to investigate loca

  2. Double Layered Sheath in Accurate HV XLPE Cable Modeling

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Silva, J. De; Bak, Claus Leth;

    2010-01-01

    This paper discusses modelling of high voltage AC underground cables. For long cables, when crossbonding points are present, not only the coaxial mode of propagation is excited during transient phenomena, but also the intersheath mode. This causes inaccurate simulation results for high frequency ...

  3. Estimation of Medium Voltage Cable Parameters for PD Detection

    DEFF Research Database (Denmark)

    Villefrance, Rasmus; Holbøll, Joachim T.; Henriksen, Mogens

    1998-01-01

    Medium voltage cable characteristics have been determined with respect to the parameters having influence on the evaluation of results from PD-measurements on paper/oil and XLPE-cables. In particular, parameters essential for discharge quantification and location were measured. In order to relate...

  4. 46 CFR 113.50-20 - Distribution of cable runs.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Distribution of cable runs. 113.50-20 Section 113.50-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Public Address Systems § 113.50-20 Distribution of cable runs. (a)...

  5. 46 CFR 111.12-9 - Generator cables.

    Science.gov (United States)

    2010-10-01

    ... REQUIREMENTS Generator Construction and Circuits § 111.12-9 Generator cables. (a) The current-carrying capacity of generator cables must not be: (1) Less than 115 percent of the continuous generator rating; or (2) Less than 115 percent of the overload for a machine with a 2 hour or greater overload rating....

  6. Ground Loop Impedance of Long EHV Cable Lines

    DEFF Research Database (Denmark)

    Ohno, Teruo; Bak, Claus Leth; Sørensen, Thomas K.

    2012-01-01

    The distance protection scheme without communication is often applied to the backup protection of EHV cable lines. For a reliable operation of a ground distance relay, the ground loop impedance of EHV cable lines needs to have a linear relationship to the distance from the relay location to the f...

  7. Metal flame spray coating protects electrical cables in extreme environment

    Science.gov (United States)

    Brady, R. D.; Fox, H. A.

    1967-01-01

    Metal flame spray coating prevents EMF measurement error in sheathed instrumentation cables which are externally attached to cylinders which were cooled on the inside, but exposed to gamma radiation on the outside. The coating provides a thermoconductive path for radiation induced high temperatures within the cables.

  8. Optimized and practical electrical joints for CORC type HTS cables

    Science.gov (United States)

    Mulder, T.; Dudarev, A.; van der Laan, D. C.; Mentink, M. G. T.; Dhallé, M.; ten Kate, H. H. J.

    2015-12-01

    Within CERN the development of REBCO-CORC (Conductor On Round Core) type cables is pursued in view of possible application in future detector and accelerator magnets. An important issue is the design and qualification of terminations for connecting CORC cables mutually or to bus-bars. A termination design is envisaged that combines a simple manufacturing process with a lowest possible joint terminal resistance in the few nΩ range at 4.2 K, first for a single CORC cable and subsequently for CORC based Cable-in-Conduit Conductors. The investigation concerns the effect of tapering the CORC cable within the joint to form a staircase like geometry, which allows current to pass more directly from the copper joint casing to the inner REBCO layers of the CORC cable. Simulations have shown a substantial decrease in joint resistance at operating current in the case both CORC cable and joint casing are tapered. The CORC cable and new joint were tested at CERN. In this paper, some details of the new joint design, fabrication process, and model are presented and the results are summarized.

  9. Optimized and practical electrical joints for CORC type HTS cables

    CERN Document Server

    Mulder, T; van der Laan, D C; Mentink, M G T; Dhallé, M; ten Kate, H H J

    2015-01-01

    Within CERN the development of REBCO-CORC (Conductor On Round Core) type cables is pursued in view of possible application in future detector and accelerator magnets. An important issue is the design and qualification of terminations for connecting CORC cables mutually or to bus-bars. A termination design is envisaged that combines a simple manufacturing process with a lowest possible joint terminal resistance in the few nΩ range at 4.2 K, first for a single CORC cable and subsequently for CORC based Cable-in-Conduit Conductors. The investigation concerns the effect of tapering the CORC cable within the joint to form a staircase like geometry, which allows current to pass more directly from the copper joint casing to the inner REBCO layers of the CORC cable. Simulations have shown a substantial decrease in joint resistance at operating current in the case both CORC cable and joint casing are tapered. The CORC cable and new joint were tested at CERN. In this paper, some details of the new joint design, fabric...

  10. Nuclear-Hardfibre Optic Cable Assemblies for Tactical Systems,

    Science.gov (United States)

    A nuclear hard fibre optic cable assembly has been developed for the US Army FOTS(LH) programme on behalf of CECOM, Fort Monmouth. The fibre is based...built equipment. The fibre optic cable assembly is completed with expanded beam hermaphrodite connectors. An extensive qualification test programme has

  11. SIMULATION OF ELECTROMAGNETIC PICKUP ON CCTV COAXIAL CABLE

    Directory of Open Access Journals (Sweden)

    O. V. Boiprav

    2013-01-01

    Full Text Available The utilization of computer-aided design FEKO for simulation of electromagnetic interference on coaxial cables of different types, such as those used in CCTV (RG59/U, RG11/U, RG179/U is proposed. Item and parameters selection for this simulation rationale is given. The obtained results are described and analyzed. It was found that a cable RG179U is the most vulnerable to external electromagnetic radiation among of all coaxial cables used in the CCTV design. It was revealed that the electromagnetic interference levels on coaxial cable depends on this one length and takes maximum value when it is a multiple of the external electromagnetic radiation wavelength. A method for electromagnetic interference on the cable network CCTV reduction is proposed.

  12. Life-assessment technique for nuclear power plant cables

    Science.gov (United States)

    Bartoníček, B.; Hnát, V.; Plaček, V.

    1998-06-01

    The condition of polymer-based cable material can be best characterized by measuring elongation at break of its insulating materials. However, it is not often possible to take sufficiently large samples for measurement with the tensile testing machine. The problem has been conveniently solved by utilizing differential scanning calorimetry technique. From the tested cable, several microsamples are taken and the oxidation induction time (OIT) is determined. For each cable which is subject to the assessment of the lifetime, the correlation of OIT with elongation at break and the correlation of elongation at break with the cable service time has to be performed. A reliable assessment of the cable lifetime depends on accuracy of these correlations. Consequently, synergistic effects well known at this time - dose rate effects and effects resulting from the different sequence of applying radiation and elevated temperature must be taken into account.

  13. Dynamic Response Analysis of Towed Cable During Deployment/Retrieval

    Institute of Scientific and Technical Information of China (English)

    WANG Fei; HUANG Guo-liang; DENG De-heng

    2008-01-01

    A numerical approach was developed to analyze the transient behavior of towed cable during ac- tively controlled deployment/retrieval (DR). The cable motion is described by the lumped parameter method, its corresponding boundary conditions are presented. In view of its varying length during DR, two auxiliary arguments are introduced to describe its continuous varying length and discrete number of nodes(equations), the length is determined by the pay out(or reel-in) rate, which is then used to determine the node number by a logic relation. For the discrete mathematical model of towed cable, an algorithm was developed to deal with the discrete governing equations. The simulation results indicate that the cable experiences more com- plex motions due to its varying length, and tension fluctuates seriously in the startup and ending stage of deployment/retrieval. The effect of towing ship's motion in waves on cable during deployment/retrieval is also considered via numerical simulation.

  14. Advanced programs for ampacity calculations of power cables

    Energy Technology Data Exchange (ETDEWEB)

    Anders, G.J.; Rodolakis, T.

    1996-11-01

    For several years the Cable Ampacity Program (CAP) has been used by both utility and consulting engineers involved in thermal design of cable installations. CAP is capable of addressing both steady state and transient thermal rating calculations. A study was conducted to further strengthen the analytical capabilities of CAP in order to accommodate recently introduced changes in the International Standards, and to address particular cable installations often encountered in practice. As a result, CAP features the following improvements: (1) representation of cables on riser poles, (2) improved loss computations, (3) representation of multiple cables per phase, and (4) automatic reading of load curve data from ASCII files. A CAP user manual is included. tabs., figs.

  15. Geometrical nonlinear stability analyses of cable-truss domes

    Institute of Scientific and Technical Information of China (English)

    高博青; 卢群鑫; 董石麟

    2003-01-01

    The nonlinear finite element method is used to analyze the geometrical nonlinear stability of cable-truss domes with different cable distributions. The results indicate that the critical load increases evidently when cables, especially diagonal cables, are distributed in the structure. The critical loads of the structure at different rise-span ratios are also discussed in this paper. It was shown that the effect of the tensional cable is more evident at small rise-span ratio. The buckling of the structure is characterized by a global collapse at small rise-span ratio; that the torsional buckling of the radial truss occurs at big rise-span ratio; and that at proper rise-span ratio, the global collapse and the lateral buckling of the truss occur nearly simultaneously.

  16. Extracting modal parameters of a cable on shaky motion pictures

    Science.gov (United States)

    Hwa Kim, Byeong

    2014-12-01

    A set of modal parameters of a cable are extracted from a motion picture captured by a digital camera operated with shaking hands. It is difficult to identify the center of the targets attached to the cable surface from the blurred motion image of the cable, because of the high-speed motion of the cable, low sampling frequency of the camera, and the effect of shaking hands on the motion pictures. This paper proposes a multi-template matching algorithm to solve these difficulties. In addition, a sensitivity-based system identification algorithm is proposed for extracting the natural frequencies and the damping ratios from ambient cable vibration data. Three sets of vibration tests are performed to examine the validity of the proposed algorithms. The results show that the proposed approach of using these two algorithms is fairly feasible for extracting modal parameters from severely blurred motion pictures.

  17. Overcurrent experiments on HTS tape and cable conductor

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Jensen, Kim Høj; Træholt, Chresten;

    2001-01-01

    their critical current. In this light, it is important to investigate the response of HTS tapes and cable conductors to overcurrents several times the critical current. A number of experiments have been performed on HTS tapes and cable conductors, with currents up to 20 times the critical current. During...... overcurrent experiments, the voltage, and the temperature were measured as functions of time in order to investigate the dynamic behavior of the HTS tape and cable conductor. After each experiment, damage to the superconductors was assessed by measuring the critical current. Preliminary results show...... that within seconds an HTS tape (critical current=17 A) heats above room temperature with an overcurrent larger than 140 A. Similar overcurrent experiments showed that a HTS cable conductor could sustain damage with overcurrents exceeding 10 times the critical current of the cable conductor....

  18. Electric Propulsion Cables For Milli-Newton Thrusters

    Science.gov (United States)

    Jakob, Manfred; Bertrand, Arnaud; El-Idrissi, Mohamed; Schaper, Wolfgang, , Dr.

    2011-10-01

    AXON' Kabel GmbH, is developing and manufacturing cables and connectors up to complete interconnect systems for all types of applications needed in Space. As a request from ESA, AXON has developed a new generation of cables suitable for current and future applications to feed electric propulsion thruster systems in spacecraft with electric power. Under this project the main objectives were to find and select materials for the composition to produce a cable withstanding quite strongrequirements for operating temperature, radiation resistance, high voltage application and in variants to various current ratings (A); the cable construction will also include ESD immunisation. The paper will summarise the specification achieved and will give an overview on the test results with the prototype cables.

  19. System and method for sub-sea cable termination

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Qin; Yin, Weijun; Zhang, Lili

    2016-04-05

    An electrical connector includes a first cable termination chamber configured to receive a first power cable having at least a first conductor sheathed at least in part by a first insulating layer and a first insulation screen layer. Also, the electrical connector includes a first non-linear resistive layer configured to be coupled to a portion of the first conductor unsheathed by at least the first insulation screen layer and configured to control a direct current electric field generated in the first cable termination chamber. In addition, the electrical connector includes a first deflector configured to be coupled to the first power cable and control an alternating current electric field generated in the first cable termination chamber.

  20. Response analysis of a submarine cable under fault movement

    Institute of Scientific and Technical Information of China (English)

    Liu Aiwen

    2009-01-01

    Based on the performance of submarine cables in past earthquakes, an analytical method to determine cable performance under seabed fault movement is proposed in this paper. First, common types of earthquake damage to submarine cables are summarized, which include seabed displacement induced by fault movement, submarine landslides and seabed soil liquefaction, etc. The damage is similar to damage observed to buried pipelines following land earthquakes. The Hengchun earthquake of Dec. 26, 2006 is used as a case study. The M7.2 earthquake occurred in the South China Sea at 20:26 Beijing Time, and caused 14 international submarine cables to sever and break. The results show that the proposed method predicts damage similar to that observed in the Hengchun earthquake. Based on parametric studies of the influence of the water depth and the magnitude of the submarine earthquake, countermeasures to prevent damage to submarine cables are proposed.

  1. Behaviour of French electrical cables under fire conditions

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, R.; Chaussard, M.; Gonzalez, R.; Lacoue, J.; Mattei, J.M.; Such, J.M

    2001-12-01

    A fire Probabilistic Safety Assessment - called fire PSA - is being carried out by the French Institute of Nuclear Safety and Protection (IPSN) to be used in the framework of the safety assessment of operating 900 MWe PWRs. The aim of this study is to evaluate the core damage conditional probability which could result from a fire. A fire can induce unavailability of safety equipment notably damaging electrical cables that are a significant risk contributor. The purpose of this communication is to present the electrical cable fire tests carried out by IPSN to identify the failure modes and to determine the cable damage criteria. Moreover, are indicated the impact of each kind of cable failure mode and the methodology used to estimate the conditional probability of a failure mode when cable damage occurred. (authors)

  2. First International Conference on Cable-Driven Parallel Robots

    CERN Document Server

    Pott, Andreas; Cable-Driven Parallel Robots

    2013-01-01

    This publication presents the outcome of the "First International Conference on Cable-Driven Parallel Robots" in 2012. This is the first conference to bring together the cable robot community and dedicate a forum for the international experts of this field. It contains the Know-how, ideas and experiences of active researchers developing cable-driven robots. The book presents the state of the art, including summarizing contributions and latest research results and, where relevant, the future outlook. The book covers the essential topics for cable-driven robots: classification and definition, kinematics, workspace analysis, cable modeling, control and calibration, design methodology, hardware/prototype development, experimental evaluation, application reports and new application concepts.

  3. Analytical Calculation of Current Distribution in Multistrand Superconducting Cables

    CERN Document Server

    Bottura, L; Fabbri, M G

    2003-01-01

    In recent years the problem of current distribution in multistrand superconducting cables has received increasing attention for large scale superconductivity applications due to its effect on the stability of fusion magnets and the field quality of accelerator magnets. A modelling approach based on distributed parameters has revealed to be very effective in dealing with long cables made of some tens or hundreds of strands. In this paper we present a fully analytical solution equation for a distributed parameters model in cables made of an arbitrary number of strands, whose validity is subjected to symmetry conditions generally satisfied in practical cables. We give in particular analytical formulae of practical use for the estimation of the maximum strand currents, time constants and redistribution lengths as a function of the cable properties and the external voltage source.

  4. Dynamic responses of cable-stayed bridges to vehicular loading including the effects of the local vibration of cables

    Institute of Scientific and Technical Information of China (English)

    He ZHANG; Xu XIE

    2011-01-01

    Stay cables,the primary load carrying components of cable-stayed bridges (CSBs),are characterised by high flexibility which increases with the span of the bridge.This makes stay cables vulnerable to local vibrations which may have significant effects on the dynamic responses of long-span CSBs.Hence,it is essential to account for these effects in the assessment of the dynamics CSBs.In this paper,the dynamic responses of CSBs under vehicular loads are studied using the finite element method (FEM),while the local vibration of stay cables is analyzed using the substructure method.A case study of a cable-stayed steel bridge with a center span of 448 m demonstrates that stay cables undergo large displacements in the primary mode of the whole bridge although,in general,a cable's local vibrations are not obvious.The road surface roughness has significant effects on the interaction force between the deck and vehicle but little effect on the global response of the bridge.Load impact factors of the main girder and tower are small,and the impact factors of the tension of cables are larger than those of the displacements of girders and towers.

  5. A new monitoring method of cable tension of cable-stayed bridge-fiber Bragg grating method

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xu-she; DU Yan-liang; NING Chen-xiao

    2005-01-01

    A new on-line monitoring method based on fiber Bragg grating (FBG) for cable tension of cable-stayed bridge was introduced. The major structure of sensing head using in the test of cable tension is elastic annular. The FBG is attached inflexibility to the exterior surface of annulus and form straight-through sensing head. Sensing headis installed between the anchor device and stow-board of funiculus holes of the cable-stayed bridge. Accompany with the change of the outside pressure, the Bragg center reflective wavelength of optical fiber grating changed correspondingly. According to this characteristic, through demodulating the△λ, the value of the cable tension can be determined. The experiment results and the theory indicate that the test system has simple structure, good stability and linear,wide response capacity, and has no special request for tester, The measurement method for the test of ca ble tension is practical and effective.

  6. Surface Plasmons in Coaxial Metamaterial Cables

    Science.gov (United States)

    Kushwaha, Manvir S.; Djafari-Rouhani, Bahram

    2013-07-01

    Thanks to Victor Veselago for his hypothesis of negative index of refraction, meta-materials — engineered composites — can be designed to have properties difficult or impossible to find in nature: they can have both electrical permittivity (ɛ) and magnetic permeability (μ) simultaneously negative. The metamaterials — henceforth negative-index materials (NIMs) — owe their properties to subwavelength structure rather than to their chemical composition. The tailored electromagnetic response of the NIMs has had a dramatic impact on classical optics: they are becoming known to have changed many basic notions related with electromagnetism. The present article is focused on gathering and reviewing fundamental characteristics of plasmon propagation in coaxial cables fabricated of the right-handed medium (RHM) (with ɛ > 0, μ > 0) and the left-handed medium (LHM) (with ɛ < 0, μ < 0) in alternate shells starting from the innermost cable. Such structures as conceived here may pave the way to some interesting effects in relation to, for example, optical science exploiting the cylindrical symmetry of coaxial waveguides that make it possible to perform all major functions of an optical fiber communication system in which the light is born, manipulated, and transmitted without ever leaving the fiber environment, with precise control over the polarization rotation and pulse broadening. This review also covers briefly the nomenclature, classification, potential applications, and the limitations (related, for example, to the inherent losses) of the NIMs and their impact on classical electrodynamics in general, and in designing the cloaking devices in particular. A recent surge in efforts on invisibility and the cloaking devices seems to have spoiled the researchers worldwide: proposals include not only a way to hide an object without having to wrap the cloak around it, but also to replace a given object with another, thus adding to the deception even further! All this

  7. Shock-wave dynamics during oil-filled transformer explosions

    Science.gov (United States)

    Efremov, V. P.; Ivanov, M. F.; Kiverin, A. D.; Utkin, A. V.

    2017-05-01

    This paper presents a numerical and experimental study of the shock-wave processes evolving inside a closed vessel filled with mineral oil. Obtained experimental Hugoniot data for oil are compared with the corresponding data for water. It is found that compression of mineral oil and water can be described by approximately the same Hugoniot over a wide pressure range. Such similarity allows the use of water instead of mineral oil in the transformer explosion experiments and to describe the compression processes in both liquids using similar equations of state. The Kuznetsov equation of state for water is adopted for a numerical study of mineral oil compression. The features of the evolution of shock waves within mineral oil are analyzed using two-dimensional numerical simulations. Numerical results show that different energy sources may cause different scenarios of loading on the shell. The principal point is the phase transition taking place at relatively high temperatures for the case of high-power energy sources. In this case, a vapor-gaseous bubble emerges that qualitatively changes the dynamics of compression waves and the pattern of loads induced on the shell. Taking into account the features of the process together with the concept of water-oil similarity, the present work presents a new approach for experimental modeling of transformer shell destruction using an explosion with given characteristics in a water-filled shell.

  8. Shock-wave dynamics during oil-filled transformer explosions

    Science.gov (United States)

    Efremov, V. P.; Ivanov, M. F.; Kiverin, A. D.; Utkin, A. V.

    2016-08-01

    This paper presents a numerical and experimental study of the shock-wave processes evolving inside a closed vessel filled with mineral oil. Obtained experimental Hugoniot data for oil are compared with the corresponding data for water. It is found that compression of mineral oil and water can be described by approximately the same Hugoniot over a wide pressure range. Such similarity allows the use of water instead of mineral oil in the transformer explosion experiments and to describe the compression processes in both liquids using similar equations of state. The Kuznetsov equation of state for water is adopted for a numerical study of mineral oil compression. The features of the evolution of shock waves within mineral oil are analyzed using two-dimensional numerical simulations. Numerical results show that different energy sources may cause different scenarios of loading on the shell. The principal point is the phase transition taking place at relatively high temperatures for the case of high-power energy sources. In this case, a vapor-gaseous bubble emerges that qualitatively changes the dynamics of compression waves and the pattern of loads induced on the shell. Taking into account the features of the process together with the concept of water-oil similarity, the present work presents a new approach for experimental modeling of transformer shell destruction using an explosion with given characteristics in a water-filled shell.

  9. Assessment of heavy metals concentration in soils around oil filling ...

    African Journals Online (AJOL)

    GREG

    2Nuclear Chemistry and Environmental Research Center, National Nuclear .... soil samples were stored in sealed plastic containers, carefully ... of metal pollution by employing the method based on the pollution .... and animals when its concentration exceeds the safe limits ..... to runoff of agricultural waste to the station site.

  10. Antenna Mechanism of Length Control of Actin Cables.

    Directory of Open Access Journals (Sweden)

    Lishibanya Mohapatra

    2015-06-01

    Full Text Available Actin cables are linear cytoskeletal structures that serve as tracks for myosin-based intracellular transport of vesicles and organelles in both yeast and mammalian cells. In a yeast cell undergoing budding, cables are in constant dynamic turnover yet some cables grow from the bud neck toward the back of the mother cell until their length roughly equals the diameter of the mother cell. This raises the question: how is the length of these cables controlled? Here we describe a novel molecular mechanism for cable length control inspired by recent experimental observations in cells. This "antenna mechanism" involves three key proteins: formins, which polymerize actin, Smy1 proteins, which bind formins and inhibit actin polymerization, and myosin motors, which deliver Smy1 to formins, leading to a length-dependent actin polymerization rate. We compute the probability distribution of cable lengths as a function of several experimentally tuneable parameters such as the formin-binding affinity of Smy1 and the concentration of myosin motors delivering Smy1. These results provide testable predictions of the antenna mechanism of actin-cable length control.

  11. Electrical Aging Phenomena of Power Cables Aged by Switching Impulses

    Institute of Scientific and Technical Information of China (English)

    L.Cao; A.Zanwar; S.Grzybowski

    2013-01-01

    Due to the insufficient information regarding the aging phenomenon of cables caused by switching impulses,we aged 15 kV XLPE and EPR cable samples by 10000 switching impulses in experiments and tested them.Plus in order to compare the aging phenomenon under multi-stress conditions,additional EPR cable samples were aged by rated AC voltage and current with switching impulses superimposed.We used measurements of partial discharge parameters to monitor the cables' conditions during their aging process,and the AC breakdown voltages measurement to evaluate the cables after aging.Moreover,the Fourier transform infrared (FTIR) spectroscopy measurements revealed the changes of insulation materials after aging.The measurement results confirm that the accelerated aging of cable samples had taken place.The impacts of each individual aging factor are shown through the selected measurements and comparison.The study also helps to assess the reliability of the XLPE and EPR cables under similar condition while serving in power systems.

  12. Electrical Model of Balanced AC HTS Power Cable

    Science.gov (United States)

    Zuijderduin, R.; Chevtchenko, O.; Smit, J. J.; Willén, D.; Melnik, I.; Geschiere, A.

    The future electricity grid will be more sustainable and it will have more power transmission and distribution capability with more electrical power added from decentralized sources on distribution level and from wind parks and other large sources on transmission level. More interconnections and more underground transmission and distribution will be put up. Use of high temperature superconducting (HTS) power cables provides solutions to many of the future grid problems caused by these trends. In this paper we present an electrical model of a balanced 6 km-long three phase triaxial HTS power cable for the Dutch project being developed by a consortium of Alliander, Ultera™ and TUD. The cable currents in all three phases are balanced by selecting proper twist pitches and insulation thickness. The paper focuses on determining inductances, capacitances and AC losses of the balanced cable. Using the developed model, we also determine the voltage drop as function of the cable length, the neutral current and the effect of the imbalanced capacitances on the current distribution of the Dutch distribution cable. The model is validated and it can be used for accurate simulation of the electrical behaviour of triaxial HTS cables in electrical grids.

  13. Cryogenic System for a High Temperature Superconducting Power Transmission Cable

    Energy Technology Data Exchange (ETDEWEB)

    Demko, J.A.; Gouge, M.J.; Hughey, R.L.; Lue, J.W.; Martin, R.; Sinha, U.; Stovall, J.P.

    1999-07-12

    High-temperature superconducting (HTS) cable systems for power transmission are under development that will use pressurized liquid nitrogen to provide cooling of the cable and termination hardware. Southwire Company and Oak Ridge National Laboratory have been operating a prototype HTS cable system that contains many of the typical components needed for a commercial power transmission application. It is being used to conduct research in the development of components and systems for eventual commercial deployment. The cryogenic system was built by Air Products and Chemicals, Allentown, Pennsylvania, and can circulate up to 0.35 kg/s of liquid nitrogen at temperatures as low as 67 K at pressures of 1 to 10 bars. Sufficient cooling is provided for testing a 5-m-long HTS transmission cable system that includes the terminations required for room temperature electrical connections. Testing of the 5-m HTS transmission cable has been conducted at the design ac conditions of 1250 A and 7.5 kV line to ground. This paper contains a description of the essential features of the HTS cable cryogenic system and performance results obtained during operation of the system. The salient features of the operation that are important in large commercial HTS cable applications will be discussed.

  14. HEAT TRANSFER EXPERIMENTS AND ANALYSIS OF A SIMULATED HTS CABLE

    Energy Technology Data Exchange (ETDEWEB)

    Demko, J. A. [Oak Ridge National Laboratory (ORNL); Duckworth, R. C. [Oak Ridge National Laboratory (ORNL); Gouge, M. J. [Oak Ridge National Laboratory (ORNL); Knoll, D. [Oak Ridge National Laboratory (ORNL)

    2010-01-01

    Long-length high temperature superconducting (HIS) cable projects, over 1 km, are being designed that are cooled by flowing liquid nitrogen. The compact counter-flow cooling arrangement which has the supply and return stream in a single cryostat offers several advantages including smallest space requirement, least heat load, and reduced cost since a return cryostat is not required. One issue in long length HIS cable systems is the magnitude of the heat transfer radially through the cable. It is extremely difficult to instrument an HIS cable in service on the grid with the needed thermometry because of the issues associated with installing thermometers on high voltage components. A 5-meter long test system has been built that simulates a counter-flow cooled, HIS cable using a heated tube to simulate the cable. Measurements of the temperatures in the flow stream and on the tube wall can be made and compared to analysis. These data can be used to benchmark different HIS cable heat transfer and fluid flow analysis approaches.

  15. Thin semi-rigid coaxial cables for cryogenics applications

    Science.gov (United States)

    Kushino, Akihiro; Kasai, Soichi

    2013-03-01

    We have developed cryogenic coaxial cables for low temperature signal readout from sensitive devices, such as transition edge sensors, superconducting tunnel junctions, and kinetic inductance detectors. In order to reduce heat penetration into cryogenic stages, low thermal conductivity metals were chosen for both center and outer electrical conductors. Various types of coaxial cables, employing stainless-steel, cupro-nickel, brass, beryllium-copper, phosphor-bronze, niobium, and niobium-titanium, were manufactured using drawing dies. Thermal and electrical properties were investigated between 1 and 8 K. Coaxial cables made of copper alloys showed thermal conductance roughly consistent with literature, meanwhile Nb coaxial cable must be affected by the drawing process and thermal conductance was lowered. Attenuation of superconducting Nb and NbTi coaxial cables were observed to be adequately small up to above 10 GHz compared to those of normal conducting coaxial cables, which are subject to the Wiedemann-Franz law. We also measured normal conducting coaxial cables with silver-plated center conductors to improve high frequency performance.

  16. Nonlinear Dynamic Reliability of Coupled Stay Cables and Bridge Tower

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Nonlinear vibration can cause serious problems in long span cable-stayed bridges. When the internal resonance threshold is reached between the excitation frequency and natural frequency,large amplitudes occur in the cable. Based on the current situation of lacking corresponding constraint criteria, a model was presented for analyzing the dynamic reliability of coupling oscillation between the cable and tower in a cable-stayed bridge. First of all, in the case of cable sag, the d'Alembert principle is applied to studying the nonlinear dynamic behavior of the structure, and resonance failure interval of parametric oscillation is calculated accordingly. Then the dynamic reliability model is set up using the JC method. An application of this model has been developed for the preliminary design of one cable-stayed bridge located on Hai River in Tianjin, and time histories analysis as well as reliability indexes have been obtained. When frequency ratio between the cable and tower is approaching 1∶2, the reliability index is 0.98, indicating high failure probability. And this is consistent with theoretical derivation and experimental results in reference. This model, which is capable of computing the reliability index of resonance failure, provides theoretical basis for the establishment of corresponding rule.

  17. A wave lab inside a coaxial cable

    Science.gov (United States)

    Serra, João M.; Brito, Miguel C.; Alves, J. Maia; Vallera, A. M.

    2004-09-01

    The study of electromagnetic wave propagation in a coaxial cable can be a powerful approach to the study of waves at an undergraduate level. This study can explore different experimental situations, going from those where the finite velocity of propagation must be considered (distributed or transmission line behaviour), to those where this velocity may be considered infinite (lumped behaviour). We believe that the student observation of the existence of these two regimes can be important for the understanding of wave phenomena in general. In this work we show that this can be achieved using low-cost equipment and a set of quite simple experiments, such as the measurement of wave propagation velocity or the study of standing waves and resonance. The results obtained in a coherent set of selected experiments are discussed.

  18. Ultrasonic Welding of Wires and Cables

    Science.gov (United States)

    Heinz, Stefan; Wagner, Guntram; Eifler, Dietmar

    2012-03-01

    In the automobile industry, ultrasonic metal welding is an established method. At the Institute of Materials Science and Engineering (WKK) at the University of Kaiserslautern, Germany, systematic investigations of the weldability of Al-wires and flat flexible copper cables were carried out. In the case of Al-wires, joints with cross-sectional area of up to 80 mm2 and tensile shear load of about 3500 N were finally realized. Furthermore, methods to reduce unintentional adherence between the sonotrode coupling face and the Al-wires were developed. To realize FFC joints, ultrasonic spot welding systems and ultrasonic torsion welding systems were used. A central purpose of these investigations is the development of a system to enable welding through the insulation of the FFC without weakening the base material.

  19. Dissipationless conductance in a topological coaxial cable

    Science.gov (United States)

    Schuster, Thomas; Iadecola, Thomas; Chamon, Claudio; Jackiw, Roman; Pi, So-Young

    2016-09-01

    We present a dynamical mechanism leading to dissipationless conductance, whose quantized value is controllable in a (3+1)-dimensional electronic system. The mechanism is exemplified by a theory of Weyl fermions coupled to a Higgs field, also known as an axion insulator. We show that the insertion of an axial gauge flux can induce vortex lines in the Higgs field, similar to the development of vortices in a superconductor upon the insertion of magnetic flux. We further show that the necessary axial gauge flux can be generated using Rashba spin-orbit coupling or a magnetic field. Vortex lines in the Higgs field are known to bind chiral fermionic modes, each of which serves as a one-way channel for electric charge with conductance e2/h . Combining these elements, we present a physical picture, the "topological coaxial cable," illustrating how the value of the quantized conductance could be controlled in such an axion insulator.

  20. Dissipationless conductance in a topological coaxial cable

    CERN Document Server

    Schuster, Thomas; Chamon, Claudio; Jackiw, Roman; Pi, So-Young

    2016-01-01

    We present a dynamical mechanism leading to dissipationless conductance, whose quantized value is controllable, in a (3+1)-dimensional electronic system. The mechanism is exemplified by a theory of Weyl fermions coupled to a Higgs field--also known as an axion insulator. We show that the insertion of an axial gauge flux can induce vortex lines in the Higgs field, similarly to the development of vortices in a superconductor upon the insertion of magnetic flux. We further show that the necessary axial gauge flux can be generated using Rashba spin-orbit coupling or a magnetic field. Vortex lines in the Higgs field are known to bind chiral fermionic modes, each of which serves as a one-way channel for electric charge with conductance $e^2/h$. Combining these elements, we present a physical picture, the "topological coaxial cable," illustrating how the value of the quantized conductance could be controlled in such an axion insulator.

  1. Steady State Analysis of Towed Marine Cables

    Institute of Scientific and Technical Information of China (English)

    WANG Fei; HUANG Guo-liang; DENG De-heng

    2008-01-01

    Efficient numerical schemes were presented for the steady state solutions of towed marine cables. For most of towed systems, the steady state problem can be resolved into two-point boundary-value problem, or initial value problem in some special cases where the initial values are available directly. A new technique was proposed and attempted to solve the two-point boundary-value problem rather than the conventional shooting method due to its algorithm complexity and low efficiency. First, the boundary conditions are transformed into a set of nonlinear governing equations about the initial values, then bisection method is employed to solve these nonlinear equations with the aid of 4th order Runge-Kutta method. In common sense, non-uniform (sheared) current is assumed, which varies in magnitude and direction with depth. The schemes are validated through the DE Zoysa's example, then several numerical examples are also presented to illustrate the numerical schemes.

  2. An Assembly Line Balancing Problem Automotive Cables

    Directory of Open Access Journals (Sweden)

    Triki Hager

    2015-02-01

    Full Text Available In this paper, an Assembly Line Balancing Problem (ALBP is presented in a real-world automotive cables manufacturer company. This company found it necessary to balance its line, since it needs to increase the production rate. In this ALBP, the number of stations is known and the objective is to minimize cycle time where both precedence and zoning constrains must be satisfied. This problem is formulated as a binary linear program (BLP. Since this problem is NP-hard, an innovative Genetic Algorithm (GA is implemented. The full factorial design is used to obtain the better combination GA parameters and a simple convergence experimental study is performed on the stopping criteria to reduce computational time. Comparison of the proposed GA results with CPLEX software shows that, in a reasonable time, the GA generates consistent solutions that are very close to their optimal ones. Therefore, the proposed GA approach is very effective and competitive.

  3. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  4. Current Status of Cable Television in the Top-100 Broadcast Markets.

    Science.gov (United States)

    Kaplan, Stuart J.

    1978-01-01

    A study of the status of cable television in the major broadcast markets suggests that the cable industry has made very little progress in penetrating the top-100 markets, that the rate of development of new cable systems in the top-100 markets has slowed in recent years, and that the primary function of cable television is to retransmit…

  5. Low AC Loss in a 3 kA HTS Cable of the Dutch Project

    NARCIS (Netherlands)

    Chevtchenko, O.; Zuijderduin, R.; Smit, J.; Willen, D.; Lentge, H.; Thidemann, C.; Traeholt, C.; Melnik, I.; Geschiere, A.

    2012-01-01

    are: a cable has to fit in an annulus of 160 mm, with two cooling stations at the cable ends only. Existing solutions for HTS cables would lead to excessively high coolant pressure drop in the cable, potentially affecting public acceptance of the project. A way out would be to substantially reduce A

  6. The Cable Television Industry's Ongoing Commitment to Education and America's Teachers, Children and Families.

    Science.gov (United States)

    National Cable Television Association, Inc., Washington, DC.

    This cable television industry report provides a sampling of case studies and overviews which describe cable operator, multiple system operator (MSO), and program networks' initiatives, resources, and support for education and the communities they serve. The information focuses on the following categories: Cable in the Classroom; cable's high…

  7. HEAT TESTS OF POWER CABLES WITH XLPE INSULATION AT DIRECT VOLTAGES UP TO 110 KV

    Directory of Open Access Journals (Sweden)

    T.Yu. Antonets

    2015-12-01

    Full Text Available In this paper, experiment for determining the temperature difference between the elements of cable and in the open air is considered. The formation of a three cables laid in a plane with different spacing between adjacent cables. Tests to heat of cables for XLPE-polyethylene are used as a solid dielectric insulation. The line to XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. When single-core cables are installed in parallel the load current may not share equally between the parallel cables. This is because a significant proportion of the impedance of large conductors is due to self reactance and mutual reactance. Hence the spacing and relative location of each cable will have an effect on the current sharing. Calculation for each cable configuration is necessary. Possibility of using for determining the thermal properties of XLPE-cables a sheath applied over the cable surface with coefficient convection heat transfer between cable surface and the air region about it of equal zero. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function.

  8. Cable Damage Detection System and Algorithms Using Time Domain Reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G A; Robbins, C L; Wade, K A; Souza, P R

    2009-03-24

    This report describes the hardware system and the set of algorithms we have developed for detecting damage in cables for the Advanced Development and Process Technologies (ADAPT) Program. This program is part of the W80 Life Extension Program (LEP). The system could be generalized for application to other systems in the future. Critical cables can undergo various types of damage (e.g. short circuits, open circuits, punctures, compression) that manifest as changes in the dielectric/impedance properties of the cables. For our specific problem, only one end of the cable is accessible, and no exemplars of actual damage are available. This work addresses the detection of dielectric/impedance anomalies in transient time domain reflectometry (TDR) measurements on the cables. The approach is to interrogate the cable using time domain reflectometry (TDR) techniques, in which a known pulse is inserted into the cable, and reflections from the cable are measured. The key operating principle is that any important cable damage will manifest itself as an electrical impedance discontinuity that can be measured in the TDR response signal. Machine learning classification algorithms are effectively eliminated from consideration, because only a small number of cables is available for testing; so a sufficient sample size is not attainable. Nonetheless, a key requirement is to achieve very high probability of detection and very low probability of false alarm. The approach is to compare TDR signals from possibly damaged cables to signals or an empirical model derived from reference cables that are known to be undamaged. This requires that the TDR signals are reasonably repeatable from test to test on the same cable, and from cable to cable. Empirical studies show that the repeatability issue is the 'long pole in the tent' for damage detection, because it is has been difficult to achieve reasonable repeatability. This one factor dominated the project. The two-step model

  9. Cable Damage Detection System and Algorithms Using Time Domain Reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G A; Robbins, C L; Wade, K A; Souza, P R

    2009-03-24

    This report describes the hardware system and the set of algorithms we have developed for detecting damage in cables for the Advanced Development and Process Technologies (ADAPT) Program. This program is part of the W80 Life Extension Program (LEP). The system could be generalized for application to other systems in the future. Critical cables can undergo various types of damage (e.g. short circuits, open circuits, punctures, compression) that manifest as changes in the dielectric/impedance properties of the cables. For our specific problem, only one end of the cable is accessible, and no exemplars of actual damage are available. This work addresses the detection of dielectric/impedance anomalies in transient time domain reflectometry (TDR) measurements on the cables. The approach is to interrogate the cable using time domain reflectometry (TDR) techniques, in which a known pulse is inserted into the cable, and reflections from the cable are measured. The key operating principle is that any important cable damage will manifest itself as an electrical impedance discontinuity that can be measured in the TDR response signal. Machine learning classification algorithms are effectively eliminated from consideration, because only a small number of cables is available for testing; so a sufficient sample size is not attainable. Nonetheless, a key requirement is to achieve very high probability of detection and very low probability of false alarm. The approach is to compare TDR signals from possibly damaged cables to signals or an empirical model derived from reference cables that are known to be undamaged. This requires that the TDR signals are reasonably repeatable from test to test on the same cable, and from cable to cable. Empirical studies show that the repeatability issue is the 'long pole in the tent' for damage detection, because it is has been difficult to achieve reasonable repeatability. This one factor dominated the project. The two-step model

  10. Cable fire risk of a nuclear power plant; Ydinvoimalaitoksen kaapelipaloriski

    Energy Technology Data Exchange (ETDEWEB)

    Aulamo, H.

    1998-02-01

    The aim of the study is to carry out a comprehensive review of cable fire risk issues of nuclear power plants (NPP) taking into account latest fire and risk assessment research results. A special emphasis is put on considering the fire risk analysis of cable rooms in the framework of TVO Olkiluoto NPP probabilistic safety assessment. The assumptions made in the analysis are assessed. The literature study section considers significant fire events at nuclear power plants, the most severe of which have nearly led to a reactor core damage (Browns Ferry, Greifswald, Armenia, Belojarsk, Narora). Cable fire research results are also examined. 62 refs.

  11. Analysis of Statistical Distributions of Energization Overvoltages of EHV Cables

    DEFF Research Database (Denmark)

    Ohno, Teruo; Ametani, Akihiro; Bak, Claus Leth;

    Insulation levels of EHV systems have been determined based on the statistical distribution of switching overvoltages since 1970s when the statistical distribution was found for overhead lines. Responding to an increase in the planned and installed EHV cables, the authors have derived...... the statistical distribution of energization overvoltages for EHV cables and have made clear their characteristics compared with those of the overhead lines. This paper identifies the causes and physical meanings of the characteristics so that it becomes possible to use the obtained statistical distribution...... for the determination of insulation levels of cable systems....

  12. Aerodynamic stability of cable-stayed-suspension hybrid bridges

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xin-jun; SUN Bing-nan

    2005-01-01

    Three-dimensional nonlinear aerodynamic stability analysis was applied to study the aerodynamic stability of a cable-stayed-suspension (CSS) hybrid bridge with main span of 1400 meters, and the effects of some design parameters (such as the cable sag, length of suspension portion, cable plane arrangement, subsidiary piers in side spans, the deck form, etc.) on the aerodynamic stability of the bridge are analytically investigated. The key design parameters, which significantly influence the aerodynamic stability of CSS hybrid bridges, are pointed out, and based on the wind stability the favorable structural system of CSS hybrid bridges is discussed.

  13. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a second of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last six years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with Ac Cables) research project. The main topics are discussed...

  14. False mystique of broadband technology: utility entry into cable television

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, G.L.; Levy, S.A.

    1983-06-23

    The authors believe that investments by electric utilities in cable-television ownership are ill-advised. They argue here that it is more appropriate for utilities to contract for cable-television channels or to form joint ventures to obtain essential utility uses. Utility executives should recognize, they say, that the more certain purposes of their companies can be accomplished in much-less-risky ways than ownership and that cable television offers an inappropriate field for profit-making ventures by utility companies. 42 references.

  15. Ultra Low Loss Optical Fiber Cable Assemblies. Volume 2.

    Science.gov (United States)

    1983-06-07

    attenuation of each cabled fiber is calculated per paragraph 3.1.4. 4.4.5 TESi RESULTS REPORTING The pre test and post test attenuation of each cabled fiber...lg oss of a za:ad pAi: of~~~~~~~~~~~~ coe~r o ±s ;o asma -c~Ln: f cable anda)1khaa :ocaptacla -!5 . imUvab1. gtbers seda.4 crod n .2..) ~"be deaa= on

  16. Arc tracking energy balance for copper and aluminum aeronautic cables

    Science.gov (United States)

    André, T.; Valensi, F.; Teulet, P.; Cressault, Y.; Zink, T.; Caussé, R.

    2017-04-01

    Arc tracking tests have been carried out between two voluntarily damaged aeronautic cables. Copper or aluminum conductors have been exposed to short circuits under alternating current. Various data have been recorded (arc voltage and current, radiated power and ablated mass), enabling to determine a power balance, in which every contribution is estimated. The total power is mainly transferred to the cables (between 50 and 65%, depending on the current and the cable type), and causes the melting and partial vaporization of the metallic core and insulating material, or is conducted or radiated. The other part is deposited into the arc column, being either radiated, convected or conducted.

  17. Land cable systems for the connection of wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Brakelmann, Heinrich; Brueggmann, Jan [Duisburg-Essen Univ., Duisburg (Germany). Inst. of Energy Transport and -Storage; Frisch, Walter [IFK Gesellschaft m.b.H., Salzburg (Austria). CEO

    2011-07-01

    This paper reports about the application of earth ploughs for the installation of high-voltage and extra-high-voltage cables. In the first part, there is a general description of the ploughing process with its features, the plough and the plough-cavity itself as well as some impressions of installation process. The second part analyzes the current rating of a cable system, installed by earth ploughs. Beside steady-state loads, time varying loads are assumed. The temperature profile in the soil is displayed and conclusions for the moisture content of the soil are drawn. The application of new filling materials for cables in pipes is introduced. (orig.)

  18. Fiber Optic Cable Thermal Preparation to Ensure Stable Operation

    Science.gov (United States)

    Thoames Jr, William J.; Chuska, Rick F.; LaRocca, Frank V.; Switzer, Robert C.; Macmurphy, Shawn L.; Ott, Melanie N.

    2008-01-01

    Fiber optic cables are widely used in modern systems that must provide stable operation during exposure to changing environmental conditions. For example, a fiber optic cable on a satellite may have to reliably function over a temperature range of -50 C up to 125 C. While the system requirements for a particular application will dictate the exact method by which the fibers should be prepared, this work will examine multiple ruggedized fibers prepared in different fashions and subjected to thermal qualification testing. The data show that if properly conditioned the fiber cables can provide stable operation, but if done incorrectly, they will have large fluctuations in transmission.

  19. A preliminary bending fatigue spectrum for steel monostrand cables

    DEFF Research Database (Denmark)

    Winkler, Jan; Fischer, Gregor; Georgakis, Christos T.;

    2011-01-01

    This paper presents the results of the experimental study on the bending fatigue resistance of high-strength steel monostrand cables. From the conducted fatigue tests in the high-stress, low-cycle region, a preliminary bending fatigue spectrum is derived for the estimation of monostrand cable...... service life expectancy. The presented preliminary bending fatigue spectrum of high-strength monostrands is currently unavailable in the published literature. The presented results provide relevant information on the bending mechanism and fatigue characteristics of monostrand steel cables in tension...

  20. Simultaneous Thermal and Gamma Radiation Aging of Cable Polymers

    Energy Technology Data Exchange (ETDEWEB)

    Fifield, Leonard S.; Liu, Shuaishuai; Bowler, Nicola

    2016-12-19

    Polymers used in nuclear power plant electrical cable systems experience aging and degradation over time due to environmental stress including heat and gamma irradiation. Prediction of long-term cable performance has been based on results of short-term accelerated laboratory aging studies, but questions remain regarding the correlation of accelerated aging to long-term, in-plant aging. This work seeks to increase understanding of the combined effects of heat and radiation on cable polymer material aging toward addressing these questions.

  1. Cubierta de doble curvatura de cables pretensados (Finlandia

    Directory of Open Access Journals (Sweden)

    Bergholt, K.

    1966-03-01

    Full Text Available A new ice hockey stadium has been built in Tampere, Finland. It has a reinforced concrete structure and a light, double curvature, roof suspended from a network of prestressed cables. It has a rectangular planform, 63x92 m, and it can accommodate 10,000 spectators. The hockey rink is in the centre. After a brief comparison of various types of suspended roofs, the author describes his own design, and discusses the most delicate aspects of the project. The cables are anchored in lateral arched beams, whose stability is provided by external prestressed concrete ribs. The author emphasizes the importance of these beams for the overall efficiency of the project. Special care was taken to avoid curvature of the cables where these penetrate into the lateral beams, without, however, restricting the freedom of the cables to oscillate. The article describes the placing of the cables, the details of the cables themselves, and their stretching: all of which is a technology that is now well know and tried.El nuevo estadio para hockey sobre hielo, construido, en Tampere, Finlandia, a base de una estructura en hormigón armado y una cubierta ligera de doble curvatura formada por una red de cables pretensados, tiene forma rectangular con planta de 63,2 x 92 m; está previsto para 10.000 espectadores y lleva en el centro la cancha para hockey. Después de una ligera comparación de los distintos tipos de cubiertas suspendidas, el autor describe su obra y analiza las partes más sensibles de la cubierta suspendida por él proyectada. Los cables están anclados en vigas o arcos laterales cuya estabilidad está asegurada por tirantes exteriores de hormigón pretensado. El autor subraya la particular importancia que tiene la concepción de estas vigas o arcos laterales para la economía de la obra. Se tuvo especial cuidado en evitar codos en los cables donde éstos entran en las vigas o arcos laterales, sin por eso restringa la necesaria libertad de movimiento de

  2. Calibrator device for the extrusion of cable coatings

    Science.gov (United States)

    Garbacz, Tomasz; Dulebová, Ľudmila; Spišák, Emil; Dulebová, Martina

    2016-05-01

    This paper presents selected results of theoretical and experimental research works on a new calibration device (calibrators) used to produce coatings of electric cables. The aim of this study is to present design solution calibration equipment and present a new calibration machine, which is an important element of the modernized technology extrusion lines for coating cables. As a result of the extrusion process of PVC modified with blowing agents, an extrudate in the form of an electrical cable was obtained. The conditions of the extrusion process were properly selected, which made it possible to obtain a product with solid external surface and cellular core.

  3. Analysis and prevention of accident-caused faults in power cable lines

    Directory of Open Access Journals (Sweden)

    Susakova Tatyana V.

    2017-01-01

    Full Text Available To ensure fault-free operation of power cable lines it is essential to make a thorough analysis of the type of faults and their location. The paper considers the most common type of faults and main reasons for cable damage. The case study of cable faults at an urban network (Zabaikalsky Krai shows that the root cause is insulation deterioration, especially with the cables reaching the end of their 35 year lifetime. Therefore, to prevent faults and mitigate the threats it is necessary to increase surveillance of cable systems and use cables with higher reliability and functionality, e.g., XLPE cables.

  4. Aerodynamic instability of cables in transmission power lines; Inestabilidad aerodinamica en cables de lineas de transmision

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Lopez, Alberto; Vilar Rojas, Jorge Ivan; Munoz Black, Celso J. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    One of the aerodynamic instabilities of transmission power lines cables is galloping, which consists in the appearance of important cable vibrations, mainly when the wind hits orthogonally the power line. In some cases the maximum amplitude that occurs reaches several meters, even when the wind velocities in a region are well below the value used for the mechanical design of the power lines. In general terms, galloping is associated with particular climatic conditions such as low temperatures and high humidities. In these conditions a coating of ice that adheres to the cable is formed, changing its transverse cross section, propitiating the galloping, although some authors have reported galloping without ice. These climatic conditions are presented mainly in the Northern part of our country and in the high regions of the mountain zones; nevertheless, the galloping phenomenon has been reported in few cases by Comision Federal de Electricidad (CFE). The possible expansion of the power lines in these regions of the country leads to prevent the measures needed to diminish the appearance of this phenomenon. In this paper mention is made in particular of the solution adopted to the galloping problem that has appeared in the transmission power line of Salamayuca to Reforma, Ciudad Juarez, Chihuahua (CFE,1991). [Espanol] Una de las inestabilidades aerodinamicas que se presentan en los cables de lineas de transmision es el galopeo, el cual consiste en la aparicion de vibraciones importantes de los cables, sobre todo cuando el flujo del viento incide ortogonalmente a la linea. En algunos casos las amplitudes maximas que se presentan llegan a ser de varios metros, aun cuando las velocidades del viento en una region esten muy por debajo del valor empleado para el diseno mecanico de las lineas. Generalmente, el galopeo se asocia con condiciones climaticas particulares como son las bajas temperaturas y altas humedades. En estas condiciones se forma una cubierta de hielo que se

  5. Simple Program to Investigate Hysteresis Damping Effect of Cross-Ties on Cables Vibration of Cable-Stayed Bridges

    Directory of Open Access Journals (Sweden)

    Panagis G. Papadopoulos

    2012-01-01

    Full Text Available A short computer program, fully documented, is presented, for the step-by-step dynamic analysis of isolated cables or couples of parallel cables of a cable-stayed bridge, connected to each other and possibly with the deck of the bridge, by very thin pretensioned wires (cross-ties and subjected to variation of their axial forces due to traffic or to successive pulses of a wind drag force. A simplified SDOF model, approximating the fundamental vibration mode, is adopted for every individual cable. The geometric nonlinearity of the cables is taken into account by their geometric stiffness, whereas the material nonlinearities of the cross-ties include compressive loosening, tensile yielding, and hysteresis stress-strain loops. Seven numerical experiments are performed. Based on them, it is observed that if two interconnected parallel cables have different dynamic characteristics, for example different lengths, thus different masses, weights, and geometric stiffnesses, too, or if one of them has a small additional mass, then a single pretensioned very thin wire, connecting them to each other and possibly with the deck of the bridge, proves effective in suppressing, by its hysteresis damping, the vibrations of the cables.

  6. Dynamic Analysis and Vibration Attenuation of Cable-Driven Parallel Manipulators for Large Workspace Applications

    Directory of Open Access Journals (Sweden)

    Jingli Du

    2013-01-01

    Full Text Available Cable-driven parallel manipulators are one of the best solutions to achieving large workspace since flexible cables can be easily stored on reels. However, due to the negligible flexural stiffness of cables, long cables will unavoidably vibrate during operation for large workspace applications. In this paper a finite element model for cable-driven parallel manipulators is proposed to mimic small amplitude vibration of cables around their desired position. Output feedback of the cable tension variation at the end of the end-effector is utilized to design the vibration attenuation controller which aims at attenuating the vibration of cables by slightly varying the cable length, thus decreasing its effect on the end-effector. When cable vibration is attenuated, motion controller could be designed for implementing precise large motion to track given trajectories. A numerical example is presented to demonstrate the dynamic model and the control algorithm.

  7. Rain-Wind Induced Vibration Mitigation of Stay Cables by Aerodynamic Means

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jun; LI Ming-shui; LIAO Hai-li

    2009-01-01

    Stay cables with various surface profiles were tested in wind tunnel.Dimples and helical fillets were applied to mitigate the rain-wind induced vibration.The rain-wind excited responses of the cable with smooth surface were larger than those of the cables with dimples and helical fillets.At high Reynolds number,the drag coefficients of cables with dimples and helical fillets are much larger than those of smooth surface cable.

  8. Analysis of Statistical Distributions of Energization Overvoltages of EHV Cables

    DEFF Research Database (Denmark)

    Ohno, Teruo; Ametani, Akihiro; Bak, Claus Leth

    Insulation levels of EHV systems have been determined based on the statistical distribution of switching overvoltages since 1970s when the statistical distribution was found for overhead lines. Responding to an increase in the planned and installed EHV cables, the authors have derived the statist......Insulation levels of EHV systems have been determined based on the statistical distribution of switching overvoltages since 1970s when the statistical distribution was found for overhead lines. Responding to an increase in the planned and installed EHV cables, the authors have derived...... the statistical distribution of energization overvoltages for EHV cables and have made clear their characteristics compared with those of the overhead lines. This paper identifies the causes and physical meanings of the characteristics so that it becomes possible to use the obtained statistical distribution...... for the determination of insulation levels of cable systems....

  9. 77 FR 46527 - Distribution of the 2010 Cable Royalty Funds

    Science.gov (United States)

    2012-08-03

    ... have traditionally been movies and syndicated television series, sports programming, commercial and... Copyright Act for the retransmission to cable subscribers of over-the-air television and radio broadcast... Sports Claimants, Public Television Claimants, Commercial Television Claimants (represented by...

  10. 78 FR 4169 - Distribution of the 2011 Cable Royalty Funds

    Science.gov (United States)

    2013-01-18

    ... have traditionally been movies and syndicated television series, sports programming, commercial and... Copyright Act for the retransmission to cable subscribers of over-the-air television and radio broadcast... Sports Claimants, Public Television Claimants, Commercial Television Claimants (represented by...

  11. Control of critical coupling in a coiled coaxial cable resonator.

    Science.gov (United States)

    Huang, Jie; Wei, Tao; Wang, Tao; Fan, Jun; Xiao, Hai

    2014-05-01

    This paper reports a coiled coaxial cable resonator fabricated by cutting a slot in a spring-like coiled coaxial cable to produce a periodic perturbation. Electromagnetic coupling between two neighboring slots was observed. By manipulating the number of slots, critical coupling of the coiled coaxial cable resonator can be well controlled. An ultrahigh signal-to-noise ratio (over 50 dB) at the resonant frequency band was experimentally achieved from a coiled coaxial cable resonator with 38 turns. A theoretic model is developed to understand the device physics. The proposed device can be potentially used as a high quality and flexibly designed band-stop filter or a sensor in structural health monitoring.

  12. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students research......This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with AC Cables) research project. The main topics are discussed...

  13. ALOHA Cabled Observatory (ACO): Acoustic Doppler Current Profiler (ADCP): Temperature

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The University of Hawaii's ALOHA ("A Long-term Oligotrophic Habitat Assessment") Cabled Observatory (ACO) is located 100 km north of the island of Oahu, Hawaii (22...

  14. A continuum model for current distribution in Rutherford cables

    CERN Document Server

    Akhmedov, A I; Breschi, M

    2001-01-01

    An analysis of eddy currents induced in flat Rutherford-type cables by external time dependent magnetic fields has been performed. The induced currents generate in turn a secondary magnetic field which has a longitudinal periodicity (periodic pattern). The dependence of the amplitude of the pattern on the history of the cable excitation has been investigated. The study has been carried out with two different models for the simulation of current distribution in Rutherford cables, namely a network model, based on a lumped parameters circuit and a "continuum" model, based on a distributed parameters circuit. We show the results of simulations of the current distribution in the inner cable of a short LHC dipole model in different powering conditions and compare them to experimental data. (12 refs).

  15. Loss and Inductance Investigation in Superconducting Cable Conductors

    DEFF Research Database (Denmark)

    Olsen, Søren Krüger; Tønnesen, Ole; Træholt, Chresten

    1999-01-01

    An important parameter in the design and optimization of a superconducting cable conductor is the control of the current distribution among single tapes and layers. This distribution is to a large degree determined by inductances, since the resistances are low. The self and mutual inductances...... of the layers are therefore studied theoretically. The current distribution between the superconducting layers is monitored as a function of transport current, and the results are compared with the expected current distribution given by our electrical circuit model.The AC-losses are measured as a function...... of transport current and current distribution.This presentation is based on a number of experiments performed on prototype superconducting cable conductors. The critical current (1uV/cm) of the conductor at 77K was 1590 A (cable #1) and 3240 A (cable #2) respectively.At an rms current of 2 kA (50 Hz) the AC...

  16. 46 CFR 183.340 - Cable and wiring requirements.

    Science.gov (United States)

    2010-10-01

    ...; (2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; or (3) Meet § 111.60... to: (i) The metallic hull; or (ii) The common ground plate on nonmetallic vessels; and (3) Have final...

  17. ALOHA Cabled Observatory (ACO): Acoustic Doppler Current Profiler (ADCP): Velocity

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The University of Hawaii's ALOHA ("A Long-term Oligotrophic Habitat Assessment") Cabled Observatory (ACO) is located 100 km north of the island of Oahu, Hawaii (22...

  18. Calculating Parameters for a ReBCO Cable Joint Terminal

    CERN Document Server

    Vipp, Venno

    2016-01-01

    The aim of this project was to evaluate the effects of temperature and length on the design of a joint for a 6-around 1 CORC based conductor and optimize the terminal geometry for a single strand cable.

  19. Critical current measurement for design of HTS DC power cables

    Science.gov (United States)

    Watanabe, Hirofumi

    2017-02-01

    Critical currents of HTS DC power cables were calculated. In the calculation a relationship between critical current density and magnetic flux density proposed by Gömöry et al. [1] was used and the parameters used in the relationship were obtained by the critical current measurements with respect to the external magnetic field for a sample of the HTS tape. Numerical models of cables were composed and their critical currents were calculated, which showed the strong dependence on the arrangement of the HTS tapes in the cable. Critical current measurements of model cables assembled based on the calculations showed that the measured critical currents also depended on the arrangement of the HTS tapes strongly. The calculated results were compared with the experimental results, which showed that the experimental results agreed well with the calculated results.

  20. Geometrical nonlinear stability analyses of cable-truss domes

    Institute of Scientific and Technical Information of China (English)

    高博青; 卢群鑫; 董石麟

    2003-01-01

    The nonlinear finite element method is used to analyze the geometrical nonlinear stability of cabletruss domes with different cable distributions. The results indicate that the critical load increases evidently when cables, especially diagonal cables, are distributed in the structure. The critical loads of the structure at different rise-span ratios are also discussed in this paper. It was shown that the effect of the tensional cable is more evident at small rise-span ratio. The buckling of the structure is characterized by a global collapse at small rlse-span ratio ; that the torsional buckling of the radial truss occurs at big rise-span ratio; and that at proper rise-span ratio, the global collapse and the lateral buckling of the truss occur nearly simultaneously.

  1. 47 CFR 32.2410 - Cable and wire facilities.

    Science.gov (United States)

    2010-10-01

    ... SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2410 Cable and wire facilities. This account shall be used by Class B companies to record the original cost...

  2. Broadcast Service Areas, Cable, Published in Not Provided, US Army.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Broadcast Service Areas, Cable dataset as of Not Provided. Data by this publisher are often provided in Not Applicable coordinate system; in a Not Applicable...

  3. Video and Cable: Emerging Forms of Library Service.

    Science.gov (United States)

    Genova, B. K. L.

    1979-01-01

    Sketches the history of video and cable communications use in libraries, current library activities in video collection and production, problems with some library video projects, trends in video services, and plans for future video uses within libraries. (FM)

  4. Temperature Dependence of PMD of the Optical Cables

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, S.J. [Korea Electric Power Research Institute, Taejon (Korea)

    2000-03-01

    This report is relevant to the project {sup K}EPCO All-Optical Network Project{sup w}hich is being carried out by Computer and Communication Group in Power System Laboratory. This report is planned to be used as a reference guide for the PMD strategy of the KEPCO optical networks. The PMD of the optical cable installed in the air as OPGW is greatly affected by the environmental temperature change, unlike that of the optical cable installed underground. The variance was turned out to be 70% larger compared with that of underground optical cable and the time scale of the PMD was less than 5 min, in the worst case. Hence, the compensation technology should be chosen taking into account the properties of the aerial optical cables. (author). 6 refs., 3 figs., 1 tab.

  5. High temperature superconductor cable concepts for fusion magnets

    CERN Document Server

    AUTHOR|(CDS)2078397

    2013-01-01

    Three concepts of high temperature superconductor cables carrying kA currents (RACC, CORC and TSTC) are investigated, optimized and evaluated in the scope of their applicability as conductor in fusion magnets. The magnetic field and temperature dependence of the cables is measured; the thermal expansion and conductivity of structure, insulation and filling materials are investigated. High temperature superconductor winding packs for fusion magnets are calculated and compared with corresponding low temperature superconductor cases.

  6. Monopoly Quality Degradation and Regulation in Cable Television

    OpenAIRE

    Crawford, Gregory; Shum, Matthew

    2005-01-01

    Using an empirical framework based on the Mussa-Rosen model of monopoly quality choice, we calculate the degree of quality degradation in cable television markets and the impact of regulation on those choices. We find lower bounds of quality degradation ranging from 11 to 45 percent of offered service qualities. Furthermore, cable operators in markets with local regulatory oversight offer significantly higher quality, less degradation, and greater quality per dollar, despite higher prices.

  7. Analysis of DC Power Transmission Using High Tc Superconducting Cables

    Institute of Scientific and Technical Information of China (English)

    Jun-Lian Zhang; Jian-Xun Jin

    2008-01-01

    A conceptual superconducting DC cable model is designed and its magnetic fields distribution is analyzed with Ansoft/Maxwell soft. A DC Power transmission system is also studied by using the Matlab/Simulink. With the DC Line and AC Ground Fault, the system losses analysis is introduced.The analysis results mainly include the magnetic fields distribution of the HTS cable model with Ansoft/Maxwell, the system loss, the DC Line and AC Ground Fault with Matlab/Simulation.

  8. An Acoustic Source Reactive to Tow Cable Strum

    Science.gov (United States)

    2012-09-21

    shown in FIG. 3 in which the device is clamped to a tow cable 100 and which resembles a head mass of a Tonpilz transducer . The device 10 can be made of...steel or any other material appropriate for a transducer head mass. [0020] A Tonpilz transducer typically comprises a stack of piezoelectric...piezoelectric stack of a Tonpilz transducer that generates vibrational energy is replaced by the mile long tow cable 100 that generates vibrational

  9. Assessing Resilience in the Global Undersea Cable Infrastructure

    Science.gov (United States)

    2012-06-01

    Linear Program MCNF Multi-Commodity (Minimum-Cost) Network Flow PFE Power Feed Equipment Tbps Terabits per second VBA Visual Basic for...components of a modern submarine optical fiber cable system include the cables themselves, repeaters, branching units, power feed equipment ( PFE ), and...repeaters themselves while also allowing for undersea fiber connections. The PFE supply electrical current to the repeaters to support the

  10. CECOM Index of Technical Papers, International Wire and Cable Symposia,

    Science.gov (United States)

    1982-10-18

    OF POLYPROPLYENE HOMO -AND COPOLYMERS AT HIGH F REOUENCI ES 3Y: SUER(LE* Doi*. REBEILLE, J.Co C0809 J.C, 󈧬CH-I9 aoL. TWENTY SixTi SYMPOSIUov 1977 - AD...CABLE ilTH LCAC.)JG COILS F IR CABLE A."?.593 ULTIAIC\\41C. JACKFT THICKNESS AND ECC ’𔃾TRICITY MO ... k, J.C. 701 CHARAC7=ERIZATION OF CRCSSrALK IN

  11. Influence of Cable Vibrations on Connectors Used in Automotive Applications

    OpenAIRE

    AMEL Bouzera; ROCHDI El Abdi; ERWANN Carvou; NOUREDDINE Benjemâa; LAURENT Tristani; EL MOSTAFA Zindine

    2012-01-01

    In order to determine the influence of cable vibrations on the contact resistance of connectors, the cable resonant frequency and the resulting movement of both parts of the connector have been studied. The increase of contact voltage, followed by rapidfluctuations generated by wear particles, has been analysed. A test bench designed to monitor wire vibrations was used while the transferred amplitude was measured by a high sensitivity displacement sensor. The contact interface was made of cop...

  12. Succession of cable bacteria and electric currents in marine sediment

    OpenAIRE

    Schauer, Regina; Risgaard-Petersen, Nils; Kjeldsen, Kasper U.; Tataru Bjerg, Jesper J; B Jørgensen, Bo; Schramm, Andreas; Nielsen, Lars Peter

    2014-01-01

    Filamentous Desulfobulbaceae have been reported to conduct electrons over centimetre-long distances, thereby coupling oxygen reduction at the surface of marine sediment to sulphide oxidation in sub-surface layers. To understand how these ‘cable bacteria' establish and sustain electric conductivity, we followed a population for 53 days after exposing sulphidic sediment with initially no detectable filaments to oxygen. After 10 days, cable bacteria and electric currents were established through...

  13. Sensitivity analyses of cables to suspen-dome structural system

    Institute of Scientific and Technical Information of China (English)

    高博青; 翁恩豪

    2004-01-01

    The construction of the cables is a key step for erecting suspen-dome structures. In practical engineering, it is difficult to ensure that the designed pre-stresses of cables have been exactly introduced into the structures in the site; so it is necessary to evaluate the influence of the variation of the pre-stresses on the structural behavior. In the present work, an orthogonal design method was employed to investigate the pre-stressed cables' sensitivity to the suspen-dome system. The investigation was concentrated on a Kiewitt suspen-dome. Parametric studies were carried out to study the sensitivity of the structure's static behavior, dynamic behavior, and buckling loads when the pre-stresses in the cables varied. The investigation indicated that suspen-dome structures are sensitive to the pre-stresses in all cables; and that the sensitivity depended on the location of the cables and the kind of structural behavior. Useful suggestions are given at the end of the paper.

  14. Sensitivity analyses of cables to suspen-dome structural system

    Institute of Scientific and Technical Information of China (English)

    高博青; 翁恩豪

    2004-01-01

    The construction of the cables is a key step for erecting suspen-dome structures. In practical engineering, it is difficult to ensure that the designed pre-stresses of cables have been exactly introduced into the structures in the site; so it is necessary to evaluate the influence of the variation of the pre-stresses on the structural behavior. In the present work, an orthogonal design method was employed to investigate the pre-stressed cables'sensitivity to the suspen-dome system. The investigation was concentrated on a Kiewitt suspen-dome. Parametric studies were carried out to study the sensitivity of the structure's static behavior, dynamic behavior, and buckling loads when the pre-stresses in the cables varied. The investigation indicated that suspen-dome structures are sensitive to the pre-stresses in all cables; and that the sensitivity depended on the location of the cables and the kind of structural behavior. Useful suggestions are given at the end of the paper.

  15. Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments

    Science.gov (United States)

    Ramesham, Rajeshuni; Lindensmith, Christian A.; Roberts, William T.; Rainen, Richard A.

    2011-01-01

    Means have been developed for enabling fiber optic cables of the Laser Induced Breakdown Spectrometer instrument to survive ground operations plus the nominal 670 Martian conditions that include Martian summer and winter seasons. The purpose of this development was to validate the use of the rover external fiber optic cabling of ChemCam for space applications under the extreme thermal environments to be encountered during the Mars Science Laboratory (MSL) mission. Flight-representative fiber optic cables were subjected to extreme temperature thermal cycling of the same diurnal depth (or delta T) as expected in flight, but for three times the expected number of in-flight thermal cycles. The survivability of fiber optic cables was tested for 600 cumulative thermal cycles from -130 to +15 C to cover the winter season, and another 1,410 cumulative cycles from -105 to +40 C to cover the summer season. This test satisfies the required 3 times the design margin that is a total of 2,010 thermal cycles (670 x 3). This development test included functional optical transmission tests during the course of the test. Transmission of the fiber optic cables was performed prior to and after 1,288 thermal cycles and 2,010 thermal cycles. No significant changes in transmission were observed on either of the two representative fiber cables subject through the 3X MSL mission life that is 2,010 thermal cycles.

  16. Energy based optimization of viscous-friction dampers on cables

    Science.gov (United States)

    Weber, F.; Boston, C.

    2010-04-01

    This investigation optimizes numerically a viscous-friction damper connected to a cable close to one cable anchor for fastest reduction of the total mechanical cable energy during a free vibration decay test. The optimization parameters are the viscous coefficient of the viscous part and the ratio between the friction force and displacement amplitude of the friction part of the transverse damper. Results demonstrate that an almost pure friction damper with negligibly small viscous damping generates fastest cable energy reduction over the entire decay. The ratio between the friction force and displacement amplitude of the optimal friction damper differs from that derived from the energy equivalent optimal viscous damper. The reason for this is that the nonlinearity of the friction damper causes energy spillover from the excited to higher modes of the order of 10%, i.e. cables with attached friction dampers vibrate at several frequencies. This explains why the energy equivalent approach does not yield the optimal friction damper. Analysis of the simulation data demonstrates that the optimally tuned friction damper dissipates the same energy per cycle as if each modal component of the cable were damped by its corresponding optimal linear viscous damper.

  17. Rapid cable tension estimation using dynamic and mechanical properties

    Science.gov (United States)

    Martínez-Castro, Rosana E.; Jang, Shinae; Christenson, Richard E.

    2016-04-01

    Main tension elements are critical to the overall stability of cable-supported bridges. A dependable and rapid determination of cable tension is desired to assess the state of a cable-supported bridge and evaluate its operability. A portable smart sensor setup is presented to reduce post-processing time and deployment complexity while reliably determining cable tension using dynamic characteristics extracted from spectral analysis. A self-recording accelerometer is coupled with a single-board microcomputer that communicates wirelessly with a remote host computer. The portable smart sensing device is designed such that additional algorithms, sensors and controlling devices for various monitoring applications can be installed and operated for additional structural assessment. The tension-estimating algorithms are based on taut string theory and expand to consider bending stiffness. The successful combination of cable properties allows the use of a cable's dynamic behavior to determine tension force. The tension-estimating algorithms are experimentally validated on a through-arch steel bridge subject to ambient vibration induced by passing traffic. The tension estimation is determined in well agreement with previously determined tension values for the structure.

  18. Stability and normal zone propagation in YBCO CORC cables

    Science.gov (United States)

    Majoros, M.; Sumption, M. D.; Collings, E. W.; van der Laan, D.

    2016-04-01

    In this work, a two layer conductor on round core cable was tested for stability and normal zone propagation at 77 K in a liquid nitrogen bath. The cable was instrumented with voltage taps and wires on each strand over the cable’s central portion (i.e. excluding the end connections of the cable with the outside world). A heater was placed in the central zone on the surface of the cable, which allowed pulses of various powers and durations to be generated. Shrinking (recovering) and expanding (not recovering) normal zones have been detected, as well as stationary zones which were in thermal equilibrium. Such stationary thermal equilibrium zones did not expand or contract, and hit a constant upper temperature while the heater current persisted; they are essentially a form of Stekly stability. Overall, the cable showed a high degree of stability. Notably, it was able to carry a current of 0.45I c cable with maximum temperature of 123 K for one minute without damage.

  19. Triaxial HTS Cable for the AEP Bixby Project

    Energy Technology Data Exchange (ETDEWEB)

    Demko, Jonathan A [ORNL; Gouge, Michael J [ORNL; Lindsay, David T [ORNL; Roden, Mark L [ORNL; Tolbert, Jerry Carlton [ORNL

    2007-01-01

    Ultera has installed a single 200-meter long high temperature superconducting (HTS) 3-phase triaxial design cable at the American Electric Power (AEP) Bixby substation in Columbus, Ohio. The cable connects a 132/13.8 kV transformer to the distribution switchgear serving seven outgoing circuits. It was designed to carry 3000 Arms. Testing of 3- to 5-meter length prototype cables, including a 5-meter prototype with full scale terminations tested at ORNL was conducted prior to the manufacture and installation of the AEP triaxial cable. These prototypes were used to demonstrate the crucial operating conditions including steady state operation at the 3000 Arms design current, high voltage operation, high voltage withstand and 110 kV impulse, and overcurrent fault capability. A summary of the results from the thermal analysis and testing conducted by Ultera and ORNL will be presented. Some analysis of the cable thermal-hydraulic response based on the testing that were used to determine some of the cable cryogenic system requirements are also presented.

  20. Long Cable Deployments During Martian Touchdown: Lessons Learned

    Science.gov (United States)

    Shafer, Michael W.; Sell, Steven W.

    2009-01-01

    The launch of NASA/JPL's next generation Mars rover is planned for the fall of 2011. The landing scheme chosen for this rover represents a step forward in unmanned payload delivery. The rover will be lowered from a rocket powered descent stage and then placed onto the surface while hanging from three bridles. During this touchdown event, the communication between the rover and descent stage is maintained by an electrical umbilical cable which is deployed in parallel with the structural bridles. During the development of the deployment device for the electrical umbilical, many obstacles were identified and overcome. Many of these challenges were due in large part to the helical nature of the packing geometry of the umbilical cable. And although none of these issues resulted in the failure of the design, they increased both development and assembly time. Many of the issues and some of the benefits of a helical deployment were not immediately apparent during the trade studies carried out during the deployment selection process. Tests were conducted upon completion of the device in order to characterize both the deployment and separation characteristics of the cable. Extraction loads were needed for inputs to touchdown models and separation dynamics were required to assess cable-rover recontact risk. Understanding the pros and cons surrounding the deployment of a helically packed cable would most certainly influence the outcome of future trade studies surrounding the selection of cable deployment options.

  1. Experimental characterization of shape memory alloy actuator cables

    Science.gov (United States)

    Biggs, Daniel B.; Shaw, John A.

    2016-04-01

    Wire rope (or cables) are a fundamental structural element in many engineering applications. Recently, there has been growing interest in stranding NiTi wires into cables to scale up the adaptive properties of NiTi tension elements and to make use of the desirable properties of wire rope. Exploratory experiments were performed to study the actuation behavior of two NiTi shape memory alloy cables and straight monofilament wire of the same material. The specimens were held under various dead loads ranging from 50 MPa to 400 MPa and thermally cycled 25 times from 140°C to 5°C at a rate of 12°C/min. Performance metrics of actuation stroke, residual strain, and work output were measured and compared between specimen types. The 7x7 cable exhibited similar actuation to the single straight wire, but with slightly longer stroke and marginally more shakedown, while maintaining equivalent specific work output. This leads to the conclusion that the 7x7 cable effectively scaled up the adaptive properties the straight wire. Under loads below 150 MPa, the 1x27 cable had up to double the actuation stroke and work output, but exhibited larger shakedown and poorer performance when loaded higher.

  2. MIMO Terminal Performance Evaluation with a Novel Wireless Cable Method

    DEFF Research Database (Denmark)

    Fan, Wei; Kyösti, Pekka; Hentilä, Lassi

    2017-01-01

    Conventional conductive method, where antennas on the device under test (DUT) are disconnected from antenna ports and replaced with radio frequency (RF) coaxial cables, has been dominantly utilized in industry to evaluate multiple-input multiple-output (MIMO) capable terminals. However, direct RF...... emulator output ports, a wireless cable connection can be achieved. The proposed method can be executed in a small RF shielded anechoic box, and offers low system cost, high measurement reliability and repeatability.......Conventional conductive method, where antennas on the device under test (DUT) are disconnected from antenna ports and replaced with radio frequency (RF) coaxial cables, has been dominantly utilized in industry to evaluate multiple-input multiple-output (MIMO) capable terminals. However, direct RF...... cable connection introduces many practical problems and a radiated method to replace cable connection is highly desirable. Existing wireless cable method relies on the knowledge of a transfer matrix between the channel emulator (CE) output ports and DUT antenna ports, and also requires an anechoic...

  3. Truncated Cables1 causes agenesis of the corpus callosum in mice.

    Science.gov (United States)

    Mizuno, Seiya; Tra, Dinh T H; Mizobuchi, Atsushi; Iseki, Hiroyoshi; Mizuno-Iijima, Saori; Kim, Jun-Dal; Ishida, Junji; Matsuda, Yoichi; Kunita, Satoshi; Fukamizu, Akiyoshi; Sugiyama, Fumihiro; Yagami, Ken-ichi

    2014-03-01

    Agenesis of the corpus callosum (ACC) is a congenital abnormality of the brain structure. More than 60 genes are known to be involved in corpus callosum development. However, the molecular mechanisms underlying ACC are not fully understood. Previously, we produced a novel transgenic mouse strain, TAS, carrying genes of the tetracycline-inducible expression system that are not involved in brain development, and inherited ACC was observed in the brains of all homozygous TAS mice. Although ACC was probably induced by transgene insertion mutation, the causative gene and the molecular mechanism of its pathogenesis remain unclear. Here, we first performed interphase three-color fluorescence in situ hybridization (FISH) analysis to determine the genomic insertion site. Transgenes were inserted into chromosome 18 ∼12.0 Mb from the centromere. Gene expression analysis and genomic PCR walking showed that the genomic region containing exon 4 of Cables1 was deleted by transgene insertion and the other exons of Cables1 were intact. The mutant allele was designated as Cables1(TAS). Interestingly, Cables1(TAS) mRNA consisted of exons 1-3 of Cables1 and part of the transgene that encoded a novel truncated Cables1 protein. Homozygous TAS mice exhibited mRNA expression of Cables1(TAS) in the fetal cerebrum, but not that of wild-type Cables1. To investigate whether a dominant negative effect of Cables1(TAS) or complete loss of function of Cables1 gives rise to ACC, we produced Cables1-null mutant mice. ACC was not observed in Cables1-null mutant mice, suggesting that a dominant negative effect of Cables1(TAS) impairs callosal formation. Moreover, ACC frequency in Cables1(+/TAS) mice was significantly lower than that in Cables1(-/TAS) mice, indicating that wild-type Cables1 interfered with the dominant negative effect of Cables1(TAS). This study indicated that truncated Cables1 causes ACC and wild-type Cables1 contributes to callosal formation.

  4. Analysis of Harmonic Vibration of Cable-Stayed Footbridge under the Influence of Changes of the Cables Tension

    Directory of Open Access Journals (Sweden)

    Pakos Wojciech

    2015-09-01

    Full Text Available The paper presents numerical analysis of harmonically excited vibration of a cable-stayed footbridge caused by a load function simulating crouching (squats while changing the static tension in chosen cables. The intentional synchronized motion (e.g., squats of a single person or group of persons on the footbridge with a frequency close to the natural frequency of the structure may lead to the resonant vibrations with large amplitudes. The appropriate tension changes in some cables cause detuning of resonance on account of stiffness changes of structures and hence detuning in the natural frequency that is close to the excitation frequency. The research was carried out on a 3D computer model of a real structure - a cable-stayed steel footbridge in Leśnica, a quarter of Wrocław, Poland, with the help of standard computer software based on FEM COSMOS/M System.

  5. Analysis of Harmonic Vibration of Cable-Stayed Footbridge under the Influence of Changes of the Cables Tension

    Science.gov (United States)

    Pakos, Wojciech

    2015-09-01

    The paper presents numerical analysis of harmonically excited vibration of a cable-stayed footbridge caused by a load function simulating crouching (squats) while changing the static tension in chosen cables. The intentional synchronized motion (e.g., squats) of a single person or group of persons on the footbridge with a frequency close to the natural frequency of the structure may lead to the resonant vibrations with large amplitudes. The appropriate tension changes in some cables cause detuning of resonance on account of stiffness changes of structures and hence detuning in the natural frequency that is close to the excitation frequency. The research was carried out on a 3D computer model of a real structure - a cable-stayed steel footbridge in Leśnica, a quarter of Wrocław, Poland, with the help of standard computer software based on FEM COSMOS/M System.

  6. Clinical evauation on axial length and intraocular lens power measurementin silicone oil-filled eyes using A-scan ultrasound%A超测量硅油填充眼眼轴及人工晶状体度数的临床评价

    Institute of Scientific and Technical Information of China (English)

    康欣乐; 李明新

    2013-01-01

    Objective To evaluate the accuracy of axial length and intraocular lens (IOL) measurement in silicone oil - filled eyes using A - scan ultrasound. Methods The cuvette was put with the silicone oil taken from the patients ' eyes, pure silicone oil and balanced salt solution. The speed of ultrasonic wave in these solvent was measured with empir -ical method using Compat tach Ⅱ A/B acoustic instrument of French QUANTEL MEDICAL company . Then the measured axial length was corrected to evaluate the accurate power of IOL . 25 patients who had vitrectomy and silicone oil filled surgery were collected. Firstly, using the recognized acoustic speed of 0x5700 to measure the axial length of the sick eye. Secondly, using the speed by our experiment to measure the sick eye in sitting position and in supine position . Fi-naly, the power of IOL was then calculated through SRK II formula by the axial length in sitting position. They received silicone oil extraction and cataract phacoemulsification and IOL implantation in one operation . 3 months after surgery, all eyes were reexamined and the actual axial length were measured again . The eye axial length and the best correct visual a -cuity were compared before and after the operation. The postoperative refraction and preoperative expected refraction was compared. Results The mean width of colorimetric cuvettes filled with pure Ox5700 silicone oil was (31.440 ±0.011) mm, that filled with the oil taken from patients' eyes was (31.420 ± 0.047 ) mm. There was no difference between them. The width of colorimetric cuvettes filled with the balanced salt solution was 21.07 mm. The recognized acoustic speed of Ox5700 silicone oil was 990 m/s. Before the surgrey, the mean axial length under the acoustic speed of 990 m/s in sili-cone oil tamponade eyes was (23. 219 ±0.125) mm. The mean axial length under the acoustic speed of 1 027m/s in sili-cone oil tamponade eyes was (24. 103 ±0. 135) mm in sitting position and was (24. 116 ±0. 128

  7. Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

    Energy Technology Data Exchange (ETDEWEB)

    Glass, Samuel W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fifield, Leonard S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hartman, Trenton S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-30

    This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests that are

  8. Parameters analysis for assistant cables of system for transient main cable and catwalk of long-span suspension bridges at construction stages

    Science.gov (United States)

    Li, Shengli; Ou, Jinping

    2009-03-01

    On the basis of static, dynamic and transient analysis for the prestressing cable structures, the parameters to control the vibration of the system for transient main cables and catwalk of some long-span suspension bridge at the construction stages with the assistant cables are investigated adopting the method of the finite element considering the geometry nonlinearity. The review and prospect to control vibration with assistant cables are summarized, the finite element modeling of the system for transient main cables and catwalk is established, and the influence of the position of the assistant cables, disposed fashion and the tensile forces upon the critical frequencies of the system for transient main cables and catwalk is researched. At the same time, the effect of the damp and the tensile forces of the assistant cables on the equivalent damping ratio of the system for transient main cables and catwalk inside and outside the plane is studied and the effect to control the vibration of the system is analysed. In the end, the influence of the transformation for the tensile forces about assistant cables upon those of the transient main cables and catwalk is also investigated. Results show that, to increase the critical frequencies of the system, the assistant cables should be laid vertically with the main cables and be located in interim span or between the tower and interim span, and to increase the amount of the assistant cables can increase the critical frequencies ,and to increase the rigidities of the assistant cables can improve the ones of the transient main cables but decrease the anti-torsion ability of the catwalks, and to increase the damp of the assistant cables can improve the vibration of the transient main cables inside and outside the plane but the result is little outside the plane, and in addition the effect of the rigidities of the assistant cables is larger outside the plane but is little inside the plane. The results also show that the

  9. Design considerations for high-power VHF radar transceivers: Phase matching long coaxial cables using a cable radar

    Science.gov (United States)

    Johnson, P. E.; Ecklund, W. L.

    1983-01-01

    The Poker Flat 49.92-MHz MST radar uses 64 phase-controlled transmitters in individual shelters distributed throughout the antenna array. Phase control is accomplished by sampling the transmitted pulse at the directional coupler of each transmitter and sending the sample pulse back to a phase-control unit. This method requires phase matching 64 long (256 meter) coaxial cables (RG-213) to within several electrical degrees. Tests with a time domain reflectometer showed that attenuation of high frequency components in the long RG-213 cable rounded the leading edge of the reflected pulse so that the cables could only be measured to within 50 cm (about 45 deg at 49.92 MHz). Another measurement technique using a vector voltmeter to compare forward and reflected phase required a directional coupler with unattainable directivity. Several other techniques were also found lacking, primarily because of loss in the long RG-213 cables. At this point it was realized that what was needed was a simple version of the phase-coherent clear-air radar, i.e., a cable radar. The design and operation of this cable are described.

  10. High-temperature superconducting conductors and cables

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, D.E.; Maley, M.P.; Boulaevskii, L.; Willis, J.O.; Coulter, J.Y.; Ullmann, J.L.; Cho, Jin; Fleshler, S.

    1996-09-01

    This is the final report of a 3-year LDRD project at LANL. High-temperature superconductivity (HTS) promises more efficient and powerful electrical devices such as motors, generators, and power transmission cables; however this depends on developing HTS conductors that sustain high current densities J{sub c} in high magnetic fields at temperatures near liq. N2`s bp. Our early work concentrated on Cu oxides but at present, long wire and tape conductors can be best made from BSCCO compounds with high J{sub c} at low temperatures, but which are degraded severely at temperatures of interest. This problem is associated with thermally activated motion of magnetic flux lines in BSCCO. Reducing these dc losses at higher temperatures will require a high density of microscopic defects that will pin flux lines and inhibit their motion. Recently it was shown that optimum defects can be produced by small tracks formed by passage of energetic heavy ions. Such defects result when Bi is bombarded with high energy protons. The longer range of protons in matter suggests the possibility of application to tape conductors. AC losses are a major limitation in many applications of superconductivity such as power transmission. The improved pinning of flux lines reduces ac losses, but optimization also involves other factors. Measuring and characterizing these losses with respect to material parameters and conductor design is essential to successful development of ac devices.

  11. An Analytical Study of Power Line Effect on UTP Cable using Lumped Circuit Components

    Directory of Open Access Journals (Sweden)

    Mitamoni Sarma

    2013-11-01

    Full Text Available The paper defines the term electrical noise with its types. Electromagnetic Interference (EMI, which is one type of electrical noise, is also defined and general techniques used for controlling EMI are described. Networking cables are affected by the EMI effect caused by a nearby power cable and data transmission through Unshielded Twisted Pair (UTP cable, which is the mostly effected cable by EMI, may be degraded for it. Today, UTP cable is the most popular networking cable supporting 10G Ethernet. The most common effective methods for reduction of EMI effect on UTP cable, physical separation and use of shielding are described. EMI is caused by coupling mechanisms between source of interference and receptor. The two types of couplings are capacitive coupling and inductive coupling. The paper analyses and models the two couplings using lumped circuit components and electric circuit analysis considering power cable as the source of interference and networking cable as the receptor circuit of EMI.

  12. Design, analysis and control of cable-suspended parallel robots and its applications

    CERN Document Server

    Zi, Bin

    2017-01-01

    This book provides an essential overview of the authors’ work in the field of cable-suspended parallel robots, focusing on innovative design, mechanics, control, development and applications. It presents and analyzes several typical mechanical architectures of cable-suspended parallel robots in practical applications, including the feed cable-suspended structure for super antennae, hybrid-driven-based cable-suspended parallel robots, and cooperative cable parallel manipulators for multiple mobile cranes. It also addresses the fundamental mechanics of cable-suspended parallel robots on the basis of their typical applications, including the kinematics, dynamics and trajectory tracking control of the feed cable-suspended structure for super antennae. In addition it proposes a novel hybrid-driven-based cable-suspended parallel robot that uses integrated mechanism design methods to improve the performance of traditional cable-suspended parallel robots. A comparative study on error and performance indices of hybr...

  13. Computation of Electric Field and Thermal Properties of 3-Phase Cable

    Directory of Open Access Journals (Sweden)

    Hemsingh Lunavath

    2012-06-01

    Full Text Available The high voltage electric power is generally transmitted by underground cable in urban, considering about the high cost for underground cable, it is necessary for us to get accurately biggest ampacity of cables in order to ensure the operation of cables in safe. The Cross linked polyethylene (XLPE insulated power cables are used for transmission and distribution of electrical power for higher voltage level. In this paper a three phase high voltage power cable buried in soil and it can be used to investigate electrical and thermal properties of cable. An underground cable of 132kV electric field, voltage distribution using finite element method (FEM, analytical method for calculating ampacity of cable and temperature distribution is presented and verified same by using COMSOL multiphysics software.

  14. New Passive Methodology for Power Cable Monitoring and Fault Location

    Science.gov (United States)

    Kim, Youngdeug

    The utilization of power cables is increasing with the development of renewable energy and the maintenance replacement of old overhead power lines. Therefore, effective monitoring and accurate fault location for power cables are very important for the sake of a stable power supply. The recent technologies for power cable diagnosis and temperature monitoring system are described including their intrinsic limitations for cable health assessment. Power cable fault location methods are reviewed with two main categories: off-line and on-line data based methods. As a diagnostic and fault location approach, a new passive methodology is introduced. This methodology is based on analyzing the resonant frequencies of the transfer function between the input and output of the power cable system. The equivalent pi model is applied to the resonant frequency calculation for the selected underground power cable transmission system. The characteristics of the resonant frequencies are studied by analytical derivations and PSCAD simulations. It is found that the variation of load magnitudes and change of positive power factors (i.e., inductive loads) do not affect resonant frequencies significantly, but there is considerable movement of resonant frequencies under change of negative power factors (i.e., capacitive loads). Power cable fault conditions introduce new resonant frequencies in accordance with fault positions. Similar behaviors of the resonant frequencies are shown in a transformer (TR) connected power cable system with frequency shifts caused by the TR impedance. The resonant frequencies can be extracted by frequency analysis of power signals and the inherent noise in these signals plays a key role to measure the resonant frequencies. Window functions provide an effective tool for improving resonant frequency discernment. The frequency analysis is implemented on noise laden PSCAD simulation signals and it reveals identical resonant frequency characteristics with theoretical

  15. Ocean Observing using SMART subsea telecommunications cable systems

    Science.gov (United States)

    Howe, B. M.

    2015-12-01

    Planning is underway to integrate ocean sensors into SMART subsea cable systems providing basin and ultimately global array coverage within the next decades (SMART: Scientific Monitoring And Reliable Telecommunications). SMART cables will: contribute to the understanding of ocean dynamics and climate; improve knowledge of earthquakes and forecasting of tsunamis; and complement and enhance existing satellite and in-situ observing systems. SMART cables will be a first order addition to the ocean observing system, with unique contributions, strengthening and complementing satellite and in situ systems. Cables spanning the ocean basins with repeaters every ~50 km will host sensors/mini-observatories, providing power and real-time communications. The current global infrastructure of commercial submarine telecommunications cable systems consists of 1 Gm of cable with ~20,000 repeaters (to boost optical signals); the overall system is refreshed and expanded on time scales of 10 - 20 years and individual systems have lifetimes in excess of 25 years. Initial instrumentation of the cables with bottom temperature, pressure and acceleration sensors will provide unique information for monitoring and studying climate change and for improved tsunami and earthquake warning. These systems will be a new highly reliable, long-lived component of the ocean observing system, complementing satellite, float and other in situ platforms and measurements. Several UN agencies, the International Telecommunication Union, the World Meteorological Organization, and the UNESCO Intergovernmental Oceanographic Commission have formed a Joint Task Force to move this concept to fruition (ITU/WMO/IOC JTF; http://www.itu.int/en/ITU-T/climatechange/task-force-sc). A review of the overall planning effort and two NASA-funded workshops focusing on the ocean circulation and climate is presented. [Funding provided by NASA.

  16. Process for making RF shielded cable connector assemblies and the products formed thereby

    Science.gov (United States)

    Fisher, A.; Clatterbuck, C. H. (Inventor)

    1973-01-01

    A process for making RF shielded cable connector assemblies and the resulting structures is described. The process basically consists of potting wires of a shielded cable between the cable shield and a connector housing to fill in, support, regidize, and insulate the individual wires contained in the cable. The formed potting is coated with an electrically conductive material so as to form an entirely encompassing adhering conductive path between the cable shield and the metallic connector housing. A protective jacket is thereby formed over the conductive coating between the cable shield and the connector housing.

  17. Application of cable-supported spatial grid in dry coal shed

    Institute of Scientific and Technical Information of China (English)

    Haidong XING; Jiping HAO; Guobin XU

    2008-01-01

    This paper presented a new structural style cable-supported spatial grid, which was applied in large span dry coal sheds. The influence of configuration of cable on the force of cable and beam, the ratio of beam force to cable force and the deflection of span was investigated, and a rational configuration of cable was obtained. The results show that the cable-supported spatial grid can maximize the use of material strength, and have the advantages of low usage of steel, large span and sufficient headroom.

  18. Los prensacables como sistema de amarre de cables

    Directory of Open Access Journals (Sweden)

    Ana Patricia Garzón Fuentes

    2011-01-01

    Full Text Available En Colombia, uno de los elementos más comúnmente usados en el amarre y sujeción de cables de acero dentro de sus diferentes aplicaciones, son los prensacables o grapas, los cuales se conocen más corrientemente como perros. A pesar de ser tan conocidos y utilizados, es poca la información técnica que se tiene acerca de estos elementos, debido a que no ha existido la suficiente investigación pertinente. Esto hace que exista una gran incertidumbre respecto a la colocación, montaje, resistencia y comportamiento de los prensacables. En recientes ensayos se ha demostrado que los prensacables usados para asegurar los cables de acero en diferentes tipos de estructuras se deslizan a una carga menor que la carga de rotura de los cables que amarran. Actualmente, los diseños se realizan según la carga de rotura de los cables, por lo cual es importante estimar la carga de desIizamiento de los prensacables para que los diseños sean adecuados. Preocupada por esta situación, la Unidad de Estructuras de la Universidad Nacional de Colombia realizó un estudio tendiente a minimizar la incertidumbre existente en el empleo de esos elementos de sujeción. Para tal erecto, se efectuaren una serie de ensayos de tensión sobre probetas de cable de 1/2" y 3/4" de diámetro, amarradas con diferentes números de prensa cables de diámetros respectivos. Se utilizaron prensacables de tres marcas, dos nacionales y una importada. Con base en estos ensayos se encontré que el torque aplicado ala tuerca del prensacable cuando se realiza el montaje de éste sobre un cable, es el parámetro fundamental para un adecuado comportamiento del mismo. Además, debe colocarse una cantidad mínima de prensacables del mismo diámetro del cable que se va a amarrar para que haya una adecuada sujeción. Otro parámetro que se encontró importante fue la orientación de los prensacables en el montaje respecto a la punta muerta (lado corto del cable.

  19. Dynamic tensile test of single PET textile cables

    Directory of Open Access Journals (Sweden)

    Pasco F.

    2012-08-01

    Full Text Available The tyres conception involves for certain applications, the use of textile cables as reinforcement. During its use, the tyre undergoes temperatures variations and dynamic loading rates. The consideration of these conditions during the numeric simulations requires the knowledge of the sensitivity of the mechanical behaviour to loading rate and temperature. In this paper, we developed an experimental methodology for testing textile cable up to high strain rate. The main difficulty of testing cables is the optimization of cable fixing on the machine. For that purpose, we adapted the solution of fixing by progressive binding already used in quasi-static, while taking into account constraints inherent to high strain tests. Firstly, the mass of grips was decreased in order to get force signal less sensitive to grips inertia. The method was developed on a high speed hydraulic machine equipped with a thermal enclosure. The investigated temperatures and strain rates range from room temperature to 373 ∘K (100 ∘C and from 0,01 to 100/s, respectively. In addition, the hydraulic machine was equipped with a high speed video camera. The obtained images were analysed by a tracking technique to measure the average strain in the cable (from 50 to 20000 f/s.

  20. Touch DNA-The prospect of DNA profiles from cables.

    Science.gov (United States)

    Lim, Sharon; Subhani, Zuhaib; Daniel, Barbara; Frascione, Nunzianda

    2016-05-01

    Metal theft in the railroad industry poses significant challenges to transport investigators. Cable sheaths left behind at crime scenes, if appropriately analysed, could provide valuable evidence in a forensic investigation, but attempts at recovering DNA are not routinely made. Experiments were set up to ascertain the success in DNA recovery from the surface of cable sheaths after deposition of (a) sweat, (b) extracted DNA and (c) fingermarks. Since investigators try to collect fingermarks and often treat the cables with cyanoacrylate fuming (CNA fuming) or wet powder suspensions (WPS) to enhance the marks this study investigated the recovery of DNA from fingermarks pre- and post-enhancement. The double-swab technique and mini-taping were compared as options to recover DNA from the cable sheaths. Results demonstrate that generally, there is no significant difference between using swabs or mini-tapes to recover the DNA from the non-porous cables (p>0.05). It was also illustrated that CNA fuming performed better than WPS in terms of subsequent recovery and profiling of DNA. CNA fuming resulted in an average increase in DNA recovered via swabbing and taping (more than 4× and 8×, respectively), as compared to no treatment, with 50% of the DNA recovered after CNA fuming generating full DNA profiles.

  1. Current distribution among layers of single phase HTS cable conductor

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Y.B., E-mail: yeaber@ncepu.edu.cn [Key Laboratory of HV and EMC Beijing, State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, No. 2 Beinong Road, Changping District, Beijing 102206 (China); Wang, Y.S., E-mail: yswang@ncepu.edu.cn [Key Laboratory of HV and EMC Beijing, State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, No. 2 Beinong Road, Changping District, Beijing 102206 (China); Pi, W., E-mail: ppiiwei@ncepu.edu.cn [Key Laboratory of HV and EMC Beijing, State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, No. 2 Beinong Road, Changping District, Beijing 102206 (China); Ju, P., E-mail: jupeng-cool@153.com [Key Laboratory of HV and EMC Beijing, State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, No. 2 Beinong Road, Changping District, Beijing 102206 (China); Wang, Y.S., E-mail: wangyixuan@epri.sgcc.com.cn [Power System Department, China Electric Power Research Institute, No. 15 Qinghexiaoying East Road, Haidian District, Beijing 100198 (China)

    2014-12-15

    Highlights: • A 1.5 m long HTS model cable with 4 layers designed by the uniform current principle has been built. • It is testified that the current distribution is influenced by the proximity effect. • The magnetic flux density and current density have been analyzed. • AC losses of tested current are larger than those of uniform current. - Abstract: High temperature superconducting (HTS) power cable shows high application prospect in modern power transmission, as it is superior over conventional transmission lines in high engineering current density and environmental friendliness. Its configuration is generally composed of several HTS layers designed with the principle of uniform current distribution, but there are few experimental results to verify the distribution. In this paper, a HTS cable model was designed based on the principle of uniform current, and the current distributions among layers in an HTS cable model were measured by Rogowski coils. The results provide an important basis for design of multi-layer HTS cable.

  2. Copper Cable Recycling System - The INEEL LSDDP Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Conner, Craig C; Meservey, Richard Harlan; Rosenberger, S.

    2001-02-01

    The United States Department of Energy (DOE) continually seeks safer and more cost-effective technologies for the deactivation and decommissioning (D&D) of nuclear facilities. The Deactivation and Decommissioning Focus Area (DDFA) and the DOE’s office of Science and Technology (OST) sponsors Large Scale Demonstration and Deployment Projects (LSDDPs). The increasing number of deactivation and decommissioning (D&D) activities at nuclear facilities can generate hundreds of tons of cables per facility consuming valuable resources such as disposal space and copper. Driven by increasing environmental concerns as well as economical pressures there is a developing need for the recycling of the uncontaminated copper. As part of the LSDDP program the NUKEM Copper Cable Recycling System (CCRS) was demonstrated November 1999 at the Idaho National Engineering and Environmental Laboratory (INEEL). This process allows recovering and recycling the uncontaminated copper contained in surface contaminated cables. The NUKEM CCRS was originally developed in Germany for the use during the D&D of commercial power plants. Up to date the CCRS has successfully processed in Germany more than 200 metric tons of contaminated cables resulting in virtually 100% free release of copper under the German standards. A total of 13.5 tons non and surrogate contaminated cables in a wide variety of sizes were successfully processed during the technology demonstration at INEEL. The assessment has demonstrated the mobility and flexibility of this new process.

  3. A Study on Dynamic Response of Cable-Seabed Interaction

    Institute of Scientific and Technical Information of China (English)

    WANG Fei; HUANG Guo-liang; DENG De-heng; TU Xing-hua

    2009-01-01

    A numerical method is developed to investigate the dynamic response of cable-seabed interaction in this paper. The motion of cable is described by the Lumped Parameter Method, while the seabed, unlike the prevailing simplified model of elastic foundation, is modeled as an irregular continuous rigid surface with rebound and friction existing, and the forces exerted by the seabed consist of normal counterforce and isotropic tangential Coulomb friction resistance. To describe the detailed dynamic response, two coefficients are introduced by analogy with the theory of rigid body collision with friction. The cable-seabed kinematic and dynamic contact conditions are formulated subsequently, and are used to incorporate the seabed effect into the cable dynamics to produce a set of ordinary differential governing equations. In this paper, we employ 4th order Runge-Kutta method to solve these equations. Several simulation cases are presented to illustrate the seabed effect. The results show that friction and impact have a prominent influence on the statics and dynamics of the cable.

  4. Advanced superconducting power cable for MV urban power supply

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Frank [Nexans Deutschland GmbH, Hannover (Germany); Merschel, Frank [RWE Deutschland AG, Essen (Germany); Noe, Mathias [Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2015-07-01

    In recent years the technology of superconducting power cable systems has progressed such that the technical hurdles preparing for commercial applications have been mastered. Several field tests of large scale prototypes for the applications of superconducting cables as well as superconducting fault current limiters have been successfully accomplished and the technology of such systems is ready for commercialization. The presentation will give a detailed overview of the German AmpaCity project. An overview will be given on the development, manufacturing and installation of the 10 kV, 40 MVA HTS system consisting of a fault current limiter and of a 1 km cable in the city of Essen. Since it is the first time that a one kilometer HTS cable system is installed together with an HTS fault current limiter in a real grid application between two substations within a city center area, AmpaCity serves as a lighthouse project. In addition it is worldwide the longest installed HTS cable system so far. It is expected that relatively large technical advances will be made in the future of the comparatively new HTS technology, which in turn will bring associated cost reductions. For this reason, the AmpaCity pilot project in the downtown area of Essen in Germany will be an important step on the way to achieving more widespread application of HTS technology.

  5. A dual-cable noise reduction method for Langmuir probes

    Science.gov (United States)

    Yang, T. F.; Zu, Q. X.; Liu, Ping

    1995-07-01

    To obtain fast time response plasma properties, electron density and electron temperature, with a Langmuir probe, the applied probe voltage has to be swept at high frequency. Due to the RC characteristics of coaxial cables, an induced noise of a square-wave form will appear when a sawtooth voltage is applied to the probe. Such a noise is very annoying and difficult to remove, particularly when the probe signal is weak. This paper discusses a noise reduction method using a dual-cable circuit. One of the cables is active and the other is a dummy. Both of them are of equal length and are laid parallel to each other. The active cable carries the applied probe voltage and the probe current signal. The dummy one is not connected to the probe. After being carefully tuned, the induced noises from both cables are nearly identical and therefore can be effectively eliminated with the use of a differential amplifier. A clean I-V characteristic curve can thus be obtained. This greatly improves the accuracy and the time resolution of the values of ne and Te.

  6. c-Abl antagonizes the YAP oncogenic function.

    Science.gov (United States)

    Keshet, R; Adler, J; Ricardo Lax, I; Shanzer, M; Porat, Z; Reuven, N; Shaul, Y

    2015-06-01

    YES-associated protein (YAP) is a central transcription coactivator that functions as an oncogene in a number of experimental systems. However, under DNA damage, YAP activates pro-apoptotic genes in conjunction with p73. This program switching is mediated by c-Abl (Abelson murine leukemia viral oncogene) via phosphorylation of YAP at the Y357 residue (pY357). YAP as an oncogene coactivates the TEAD (transcriptional enhancer activator domain) family transcription factors. Here we asked whether c-Abl regulates the YAP-TEAD functional module. We found that DNA damage, through c-Abl activation, specifically depressed YAP-TEAD-induced transcription. Remarkably, c-Abl counteracts YAP-induced transformation by interfering with the YAP-TEAD transcriptional program. c-Abl induced TEAD1 phosphorylation, but the YAP-TEAD complex remained unaffected. In contrast, TEAD coactivation was compromised by phosphomimetic YAP Y357E mutation but not Y357F, as demonstrated at the level of reporter genes and endogenous TEAD target genes. Furthermore, YAP Y357E also severely compromised the role of YAP in cell transformation, migration, anchorage-independent growth, and epithelial-to-mesenchymal transition (EMT) in human mammary MCF10A cells. These results suggest that YAP pY357 lost TEAD transcription activation function. Our results demonstrate that YAP pY357 inactivates YAP oncogenic function and establish a role for YAP Y357 phosphorylation in cell-fate decision.

  7. Electrostatic Analysis of Annular Holes Penetrated by Shorted-Cable

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Jae Yul; Kim, Hyung Tae; Park, Hyun Shin; Cho, Young Sik [KINS, Daejeon (Korea, Republic of)

    2016-05-15

    The cabinet has an important role to protect the contained cables and digital modules for the safety function from the external electromagnetic (EM) source. Thus the immunity of an open cabinet against electromagnetic interference (EMI) numerically has been investigated using mode-matching method in. Another path for the external EM source to impinge on inner cables and digital modules is the bottom hole of the cabinet that is penetrated by various cables. Especially the EMI can detrimentally influence on the digital modules through annular space caused by sealing the bottom hole of the cabinet incompletely. Thus it is recently required that the electromagnetic interpretation in the annular hole is performed to remedy electromagnetic problems. Based on the mode-matching method, we solved the electrostatic boundary-value problem for holes penetrating shorted-cable at the bottom of a digital I and C cabinet. The Weber transform and the Hankel transform were applied to formulate the electrostatic potential. The capacitance and potential distribution generated near the penetrating shorted-cable were computed and compared with the result from the previous study.

  8. Fabrication of Rutherford-type superconducting cables for construction of dipole magnets

    Energy Technology Data Exchange (ETDEWEB)

    Scanlan, R.M.; Royet, J.; Hannaford, R.

    1988-05-01

    An experimental cabling machine has been constructed and used to investigate the fabrication of a variety of superconducting cables. These include the 23-strand and 30-strand NbTi alloy cables for the Superconducting Supercollider (SSC) and a number of experimental cables. The experimental cables include 24-strands and 36-strands as well as two-level cables with a 6 or 7-strand first level and 23 or 30-strand second level. These results were used to aid in selecting the optimum cable for the SSC dipole and quadrupole magnets. As a result of these studies, cable can now be fabricated to exacting mechanical tolerances (+/- .006 mm) and with low critical current degradation (2-5%). In addition, tooling design studies have been performed and a Prototype SSC Production Cabling Machine has been designed. The results of the cable optimization studies and the tooling design studies will be discussed. SSC cable production experience on the experimental cabling machine and the production cabling machine will be reported.

  9. Development of (RE)BCO cables for HTS power transmission lines

    Science.gov (United States)

    Mukoyama, S.; Yagi, M.; Masuda, T.; Amemiya, N.; Ishiyama, A.; Kashima, N.; Nagaya, S.; Aoki, Y.; Yoshizumi, M.; Yamada, Y.; Izumi, T.; Shiohara, Y.

    2009-10-01

    High-temperature superconducting (HTS) power cables transmit bulk power with lower loss than conventional cables. Moreover, HTS cables are expected to be constructed as a new underground cable in urban areas at lower cost compared to a high voltage XLPE cable. To put promising HTS cables to practical use, we need (RE)BCO tapes with long length, high critical current, and low cost. Recently many organizations have improved the performance of the (RE)BCO tapes, such as YBCO tapes, or other coated conductor tapes that are made with a variety of different processes. We have fabricated the conductors for the HTS power cable that was constructed of different kinds of (RE)BCO tapes and measured the I c and AC losses. We achieved significantly low AC loss of 0.1 W/m at 1 kA in the HTS conductor using narrow slit tapes that were cut by laser. Moreover, a 20 m long HTS power cable model and a cable intermediate joint were developed. Short circuit current tests were conducted on the cable system that consisted of two 10 m cables, a cable joint, and two terminations. The cables and the joint withstood the short circuit current of 31.5 kA for 2 s without damage.

  10. Development of (RE)BCO cables for HTS power transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Mukoyama, S., E-mail: mukoyama@ch.furukawa.co.j [Furukawa Electric Co. Ltd., Ichihara 290-8555 (Japan); Yagi, M. [Furukawa Electric Co. Ltd., Ichihara 290-8555 (Japan); Masuda, T. [Sumitomo Electric Industries, Ltd., Osaka 554-0024 (Japan); Amemiya, N. [Kyoto University, Kyoto 615-8510 (Japan); Ishiyama, A. [Waseda University, Tokyo 169-8555 (Japan); Kashima, N.; Nagaya, S. [Chubu Electric Power Co. Inc., Nagoya 459-8522 (Japan); Aoki, Y. [Showa Cable System Co. Ltd., Sagamihara 229-1133 (Japan); Yoshizumi, M.; Yamada, Y.; Izumi, T.; Shiohara, Y. [Superconductivity Research Laboratory, Tokyo 135-0062 (Japan)

    2009-10-15

    High-temperature superconducting (HTS) power cables transmit bulk power with lower loss than conventional cables. Moreover, HTS cables are expected to be constructed as a new underground cable in urban areas at lower cost compared to a high voltage XLPE cable. To put promising HTS cables to practical use, we need (RE)BCO tapes with long length, high critical current, and low cost. Recently many organizations have improved the performance of the (RE)BCO tapes, such as YBCO tapes, or other coated conductor tapes that are made with a variety of different processes. We have fabricated the conductors for the HTS power cable that was constructed of different kinds of (RE)BCO tapes and measured the I{sub c} and AC losses. We achieved significantly low AC loss of 0.1 W/m at 1 kA in the HTS conductor using narrow slit tapes that were cut by laser. Moreover, a 20 m long HTS power cable model and a cable intermediate joint were developed. Short circuit current tests were conducted on the cable system that consisted of two 10 m cables, a cable joint, and two terminations. The cables and the joint withstood the short circuit current of 31.5 kA for 2 s without damage.

  11. Dynamic model and workspace analysis of novel incompletely restrained cable-suspension swing system driven by two cables

    Directory of Open Access Journals (Sweden)

    Naige Wang

    2017-03-01

    Full Text Available The incompletely restrained cable-suspension swing system driven by two cables is introduced in this article. Based on wrench of forces theory and Lagrange’s equation of first kind, the static and dynamics models of incompletely restrained cable-suspension swing system driven by two cables are established, respectively. In order to obtain an intuitive understanding of the trajectory analysis, a dynamics model consisting of governing equation and geometric constraint conditions which is a set of the mixed differential-algebraic equation in mathematics is established. A typical feedback controller and an inverse model were set up to estimate the driving function. The effective workspace, which is used to guarantee an efficient swing process, mostly depends on the geometrical shape rather than the volume itself which was calculated by trajectory analysis. In order to estimate system features and ensure a limited range of tension in underconstrained spatial cable system, the probable location of unbalanced loading was evaluated by pointwise evaluation techniques during normal work.

  12. Probabilistic Modeling and Risk Assessment of Cable Icing

    DEFF Research Database (Denmark)

    Roldsgaard, Joan Hee

    assessments together with the Bayesian pre-posterior decision analysis and builds upon the quantification of Value of Information (VoI). The consequences are evaluated for different outputs of the probabilistic model to provide a basis for prioritizing risk management decision alternatives. Each step...... the bridge cables, which can cause socioeconomically expensive closures of bridges and traffic disruptions. The objective is to develop a simple model that can be used to assess the occurrence probability of ice accretion on bridge cables from readily available meteorological variables. This model is used....... The damage assessment is performed using a probabilistic approach, based on a Bayesian Probabilistic Network, where the wind environment, traffic loading, bridge specific parameters and the mechanisms that induce significant cable vibrations are the main input parameters. It is outlined how information...

  13. Laplace Synthesis Validation through Measurements on Underground Transmission Cables

    Directory of Open Access Journals (Sweden)

    Uribe-Campos Felipe Alejandro

    2014-10-01

    Full Text Available Underground cable electrical parameters ZY as well as their modal propagation characteristics are highly frequency dependent which in certain cases turns its analysis difficult. To perform electromagnetic transient studies of cables the calculation of electrical parameters is essential to obtain the waves propagation solution through the multiconductor system. At the same time this requires to solve the inverse Laplace transform on a numerical form. Although the analytic Laplace transform has an indisputable accuracy, the application of its numerical version up-to-date has not been completely accepted. A complete methodology is developed in this work to guide analyst engineers or graduate students in the calculation of electromagnetic transients of underground cable systems. Finally, to help the validation of the numerical inverse Laplace transform a scaled prototype experiment is performed in the laboratory in which a transient step-response at the remote end of an energized conductor is measured.

  14. Approximate Series Solutions for Nonlinear Free Vibration of Suspended Cables

    Directory of Open Access Journals (Sweden)

    Yaobing Zhao

    2014-01-01

    Full Text Available This paper presents approximate series solutions for nonlinear free vibration of suspended cables via the Lindstedt-Poincare method and homotopy analysis method, respectively. Firstly, taking into account the geometric nonlinearity of the suspended cable as well as the quasi-static assumption, a mathematical model is presented. Secondly, two analytical methods are introduced to obtain the approximate series solutions in the case of nonlinear free vibration. Moreover, small and large sag-to-span ratios and initial conditions are chosen to study the nonlinear dynamic responses by these two analytical methods. The numerical results indicate that frequency amplitude relationships obtained with different analytical approaches exhibit some quantitative and qualitative differences in the cases of motions, mode shapes, and particular sag-to-span ratios. Finally, a detailed comparison of the differences in the displacement fields and cable axial total tensions is made.

  15. Submarine Cables for Ocean/Climate Monitoring and Disaster Warning

    Science.gov (United States)

    Bueti, Cristina; Barnes, Chris; Meldrum, David

    2013-04-01

    A joint initiative between International Telecommunication Union (ITU), the World Meteorological Organization (WMO) and the Intergovernmental Oceanographic Commission (IOC) of UNESCO is examining novel uses for submarine telecommunication cables. The initiative addresses two main issues: the need for sustained climate-quality data from the sparsely observed deep oceans, and the desire to increase the reliability and integrity of the global tsunami warning networks. In the latter case, a significant proportion of the network suffers from failure and vandalism of the sea-surface telemetry buoys that relay the tsunami signals from the sea-bed sensor package: incorporating the sensors within a submarine cable repeater is an obvious way of increasing system reliability. At the present time, plans are well advanced to launch a pilot project with the active involvement of cable industry players.

  16. Design of a Micro Cable Tunnel Inspection Robot

    Science.gov (United States)

    Song, Wei; Liu, Lei; Zhou, Xiaolong; Wang, Chengjiang

    2016-11-01

    As the ventilation system in cable tunnel is not perfect and the environment is closed, it is easy to accumulate toxic and harmful gas. It is a serious threat to the life safety of inspection staff. Therefore, a micro cable tunnel inspection robot is designed. The whole design plan mainly includes two parts: mechanical structure design and control system design. According to the functional requirements of the tunnel inspection robot, a wheel arm structure with crawler type is proposed. Some sensors are used to collect temperature, gas and image and transmit the information to the host computer in real time. The result shows the robot with crawler wheel arm structure has the advantages of small volume, quick action and high performance-price ratio. Besides, it has high obstacle crossing and avoidance ability and can adapt to a variety of complex cable tunnel environment.

  17. Vibrations of a Shallow Cable with a Viscous Damper

    DEFF Research Database (Denmark)

    Krenk, Steen; Nielsen, Søren R. K.

    2002-01-01

    The optimal tuning and effect in terms of modal damping of a viscous damper mounted near the end of a shallow cable are investigated. The damping properties of free vibrations are extracted from the complex wavenumber. The full solution for the lower modes is evaluated numerically, and an explicit...... and rather accurate analytical approximation is obtained, generalizing recent results for a taut cable. It is found that the effect of the damper on the nearly antisymmetric modes is independent of the sag and the stiffness parameter. In contrast, the nearly symmetric modes develop regions of reduced motion...... near the ends, with increasing cable stiffness, and this reduces the effect of the viscous damper. Explicit results are obtained for the modal damping radio and for optimal tuning of the damper....

  18. Preliminary evaluation of two new cable surface innovations

    DEFF Research Database (Denmark)

    Burlina, Celeste; Georgakis, Christos T.; Larsen, S.V.;

    2015-01-01

    In this paper, the aerodynamic performance of two innovative bridge cable surfaces with concave fillets are examined and compared with traditional helical fillets. To this end, an extensive wind-tunnel test campaign was undertaken to measure the aerodynamic static force coefficients up to a Reyno......In this paper, the aerodynamic performance of two innovative bridge cable surfaces with concave fillets are examined and compared with traditional helical fillets. To this end, an extensive wind-tunnel test campaign was undertaken to measure the aerodynamic static force coefficients up...... to a Reynolds number of 3.2 x 105. The tests confirmed the results obtained from the preliminary tests performed by Kleissl and Georgakis (2013) on the prototype cable surfaces with the concave fillets. Despite a more than 100% increase of the fillet height compared to a traditional helical fillet profile...

  19. Armor corrosion monitoring of a submarine AC cable

    Energy Technology Data Exchange (ETDEWEB)

    Genesca, J. [Univ. Nacional Autonoma de Mexico (Mexico). Dept. Ingenieria Metalurgica; Perez, T. [Univ. Autonoma de Campeche (Mexico). Programa Corrosion del Golfo de Mexico; Lara, C. [CFE-LAPEM, Irapuato (Mexico)

    1997-12-01

    After the hurricane Gilberto flattened (devastated) Cancun in September 1988, the submarine cables which supplied electricity to Isla Mjueres Island remained very damaged, and it was decided to install the new ones. In 1989, four new submarine cables were installed from Punta Sam, Cancun to Isla Mujeres. Such cables, of nominal tension 34.5 KV, were manufactures with a galvanized steel armor coated with asphalt, and began operation during 1990. The object of this communication is to present the experimental procedure that gave place to the armor corrosion monitoring procedure carried out in this particular case and to compare the results with those obtained on the field. Results of the cathodic protection system applied are also presented.

  20. Cable shovel simulation modeling in the ADAMS environment

    Energy Technology Data Exchange (ETDEWEB)

    Frimpong, S.; Hu, Y.; Chang, Z. [Alberta Univ., Edmonton, AB (Canada). Centre for Advanced Energy and Minerals Research

    2003-07-01

    This paper presents a computer simulation model for cable shovels used in surface mining operations. The shovels are subject to significant wear and tear as well as fatigue failure in equipment components resulting in downtime, reduced efficiency and high production costs. The ADAMS virtual prototyping software program simulates realistic full-motion behaviour of complex mechanical systems and offers quick analysis for multiple optimal design options. Virtual prototyping reduces the need for costly physical prototypes, improves design quality and reduces product development time. The paper presents examples where the method was applied in actual mining operations. In particular, the model was used simulate the performance of cable shovels during actual digging operations. It was used to determine energy consumption under a range of digging conditions and produced efficient digging profiles. The software is also capable of simulating the critical parameters that are necessary for evaluating and optimizing the performance and energy consumption of cable shovels. 8 refs., 2 tabs., 8 figs.