WorldWideScience

Sample records for nuclear noninvasive imaging

  1. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging

    International Nuclear Information System (INIS)

    Pons, G.

    2011-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  2. Noninvasive imaging of breast cancer

    International Nuclear Information System (INIS)

    Medarova, Z.

    2009-01-01

    With the development of molecularly targeted cancer therapies, it is highly advantageous to be able to determine their efficacy, to improve overall patient survival. Non-invasive imaging techniques are currently available for visualizing different pathological conditions of the human body, but their use for cancer monitoring is limited due to the lack of tumor-specific imaging probes. This review will attempt to summarize the current clinical diagnostic approaches for breast cancer detection, staging, and therapy assessment. In addition, I will present some novel concepts from the field of molecular imaging that form the basis of some of our research. We believe that this general imaging strategy has the potential of significantly advancing our ability to diagnose breast cancer at the earliest stages of the pathology, before any overt clinical symptoms have developed, as well as to better direct the development of molecularly-targeted individualized therapy protocols.

  3. A novel triple-modality reporter gene for whole-body fluorescent, bioluminescent, and nuclear noninvasive imaging

    International Nuclear Information System (INIS)

    Ponomarev, Vladimir; Vider, Jelena; Shavrin, Aleksander; Ageyeva, Ludmila; Tourkova, Vilia; Doubrovin, Michael; Serganova, Inna; Beresten, Tatiana; Ivanova, Anna; Blasberg, Ronald; Balatoni, Julius; Bornmann, William; Gelovani Tjuvajev, Juri

    2004-01-01

    Two genetic reporter systems were developed for multimodality reporter gene imaging of different molecular-genetic processes using fluorescence, bioluminescence (BLI), and nuclear imaging techniques. The eGFP cDNA was fused at the N-terminus with HSV1-tk cDNA bearing a nuclear export signal from MAPKK (NES-HSV1-tk) or with truncation at the N-terminus of the first 45 amino acids (Δ45HSV1-tk) and with firefly luciferase at the C-terminus. A single fusion protein with three functional subunits is formed following transcription and translation from a single open reading frame. The NES-TGL (NES-TGL) or Δ45HSV1-tk/GFP/luciferase (Δ45-TGL) triple-fusion gene cDNAs were cloned into a MoMLV-based retrovirus, which was used for transduction of U87 human glioma cells. The integrity, fluorescence, bioluminescence, and enzymatic activity of the TGL reporter proteins were assessed in vitro. The predicted molecular weight of the fusion proteins (130 kDa) was confirmed by western blot. The U87-NES-TGL and U87-Δ45-TGL cells had cytoplasmic green fluorescence. The in vitro BLI was 7- and 13-fold higher in U87-NES-TGL and U87-Δ45-TGL cells compared to nontransduced control cells. The Ki of 14 C-FIAU was 0.49±0.02, 0.51±0.03, and 0.003±0.001 ml/min/g in U87-NES-TGL, U87-Δ45-TGL, and wild-type U87 cells, respectively. Multimodality in vivo imaging studies were performed in nu/nu mice bearing multiple s.c. xenografts established from U87-NES-TGL, U87-Δ45-TGL, and wild-type U87 cells. BLI was performed after administration of d-luciferin (150 mg/kg i.v.). Gamma camera or PET imaging was conducted at 2 h after i.v. administration of [ 131 I]FIAU (7.4 MBq/animal) or [ 124 I]FIAU (7.4 MBq/animal), respectively. Whole-body fluorescence imaging was performed in parallel with the BLI and radiotracer imaging studies. In vivo BLI and gamma camera imaging showed specific localization of luminescence and radioactivity to the TGL transduced xenografts with background levels of activity

  4. Imaging the pancreas: from ex vivo to non-invasive technology

    DEFF Research Database (Denmark)

    Holmberg, D; Ahlgren, U

    2008-01-01

    While many recently published reviews have covered non-invasive nuclear imaging techniques, the aim of this review is to focus on current developments in optical imaging technologies for investigating the pancreas. Several of these modalities are being developed into non-invasive, real-time monit......While many recently published reviews have covered non-invasive nuclear imaging techniques, the aim of this review is to focus on current developments in optical imaging technologies for investigating the pancreas. Several of these modalities are being developed into non-invasive, real...

  5. Noninvasive imaging of experimental lung fibrosis.

    Science.gov (United States)

    Zhou, Yong; Chen, Huaping; Ambalavanan, Namasivayam; Liu, Gang; Antony, Veena B; Ding, Qiang; Nath, Hrudaya; Eary, Janet F; Thannickal, Victor J

    2015-07-01

    Small animal models of lung fibrosis are essential for unraveling the molecular mechanisms underlying human fibrotic lung diseases; additionally, they are useful for preclinical testing of candidate antifibrotic agents. The current end-point measures of experimental lung fibrosis involve labor-intensive histological and biochemical analyses. These measures fail to account for dynamic changes in the disease process in individual animals and are limited by the need for large numbers of animals for longitudinal studies. The emergence of noninvasive imaging technologies provides exciting opportunities to image lung fibrosis in live animals as often as needed and to longitudinally track the efficacy of novel antifibrotic compounds. Data obtained by noninvasive imaging provide complementary information to histological and biochemical measurements. In addition, the use of noninvasive imaging in animal studies reduces animal usage, thus satisfying animal welfare concerns. In this article, we review these new imaging modalities with the potential for evaluation of lung fibrosis in small animal models. Such techniques include micro-computed tomography (micro-CT), magnetic resonance imaging, positron emission tomography (PET), single photon emission computed tomography (SPECT), and multimodal imaging systems including PET/CT and SPECT/CT. It is anticipated that noninvasive imaging will be increasingly used in animal models of fibrosis to gain insights into disease pathogenesis and as preclinical tools to assess drug efficacy.

  6. Nuclear imaging

    International Nuclear Information System (INIS)

    Miller, J.H.; Reid, B.S.

    1985-01-01

    Nuclear imaging, utilizing relatively low photon energy emitting isotopes, allows an assessment of anatomic configuration and organ function. This method of imaging is predicted on the utilization of physiologically active radioisotope-labeled compounds or biologically active radioisotopes. Localization of such isotopes in normal or abnormal concentrations may be due to varying physiological or pathological mechanisms

  7. Nuclear medicine imaging instrumentations for molecular imaging

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Song, Tae Yong; Choi, Yong

    2004-01-01

    Small animal models are extensively utilized in the study of biomedical sciences. Current animal experiments and analysis are largely restricted to in vitro measurements and need to sacrifice animals to perform tissue or molecular analysis. This prevents researchers from observing in vivo the natural evolution of the process under study. Imaging techniques can provide repeatedly in vivo anatomic and molecular information noninvasively. Small animal imaging systems have been developed to assess biological process in experimental animals and increasingly employed in the field of molecular imaging studies. This review outlines the current developments in nuclear medicine imaging instrumentations including fused multi-modality imaging systems for small animal imaging

  8. Diagnostic and prognostic value of non-invasive imaging in known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    Schuijf, J.D.; Poldermans, D.; Shaw, L.J.; Jukema, J.W.; Wall, E.E. van der; Lamb, H.J.; Roos, A. de; Wijns, W.; Bax, J.J.

    2006-01-01

    The role of non-invasive imaging techniques in the evaluation of patients with suspected or known coronary artery disease (CAD) has increased exponentially over the past decade. The traditionally available imaging modalities, including nuclear imaging, stress echocardiography and magnetic resonance imaging (MRI), have relied on detection of CAD by visualisation of its functional consequences (i.e. ischaemia). However, extensive research is being invested in the development of non-invasive anatomical imaging using computed tomography or MRI to allow detection of (significant) atherosclerosis, eventually at a preclinical stage. In addition to establishing the presence of or excluding CAD, identification of patients at high risk for cardiac events is of paramount importance to determine post-test management, and the majority of non-invasive imaging tests can also be used for this purpose. The aim of this review is to provide an overview of the available non-invasive imaging modalities and their merits for the diagnostic and prognostic work-up in patients with suspected or known CAD. (orig.)

  9. MRI Reporter Genes for Noninvasive Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Caixia Yang

    2016-05-01

    Full Text Available Magnetic resonance imaging (MRI is one of the most important imaging technologies used in clinical diagnosis. Reporter genes for MRI can be applied to accurately track the delivery of cell in cell therapy, evaluate the therapy effect of gene delivery, and monitor tissue/cell-specific microenvironments. Commonly used reporter genes for MRI usually include genes encoding the enzyme (e.g., tyrosinase and β-galactosidase, the receptor on the cells (e.g., transferrin receptor, and endogenous reporter genes (e.g., ferritin reporter gene. However, low sensitivity limits the application of MRI and reporter gene-based multimodal imaging strategies are common including optical imaging and radionuclide imaging. These can significantly improve diagnostic efficiency and accelerate the development of new therapies.

  10. Muscle perfusion and metabolic heterogeneity: insights from noninvasive imaging techniques

    DEFF Research Database (Denmark)

    Kalliokoski, Kari K; Scheede-Bergdahl, Celena; Kjaer, Michael

    2006-01-01

    Recent developments in noninvasive imaging techniques have enabled the study of local changes in perfusion and metabolism in skeletal muscle as well as patterns of heterogeneity in these variables in humans. In this review, the principles of these techniques along with some recent findings...... on functional heterogeneity in human skeletal muscle will be presented....

  11. Non-invasive terahertz field imaging inside parallel plate waveguides

    DEFF Research Database (Denmark)

    Iwaszczuk, Krzysztof; Andryieuski, Andrei; Lavrinenko, Andrei

    2011-01-01

    We present a non-invasive broadband air photonic method of imaging of the electric field of THz pulses propagating inside a tapered parallel plate waveguide. The method is based on field-enhanced second harmonic generation of the fundamental laser beam in an external electric field. We apply...

  12. An Image Registration Based Technique for Noninvasive Vascular Elastography

    OpenAIRE

    Valizadeh, Sina; Makkiabadi, Bahador; Mirbagheri, Alireza; Soozande, Mehdi; Manwar, Rayyan; Mozaffarzadeh, Moein; Nasiriavanaki, Mohammadreza

    2018-01-01

    Non-invasive vascular elastography is an emerging technique in vascular tissue imaging. During the past decades, several techniques have been suggested to estimate the tissue elasticity by measuring the displacement of the Carotid vessel wall. Cross correlation-based methods are the most prevalent approaches to measure the strain exerted in the wall vessel by the blood pressure. In the case of a low pressure, the displacement is too small to be apparent in ultrasound imaging, especially in th...

  13. Non-Invasive in vivo Imaging in Small Animal Research

    Directory of Open Access Journals (Sweden)

    V. Koo

    2006-01-01

    Full Text Available Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI, Computed Tomography (CT, Positron Emission Tomography (PET, bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

  14. Noninvasive imaging of hepatocellular carcinoma: From diagnosis to prognosis

    Science.gov (United States)

    Jiang, Han-Yu; Chen, Jie; Xia, Chun-Chao; Cao, Li-Kun; Duan, Ting; Song, Bin

    2018-01-01

    Hepatocellular carcinoma (HCC) is the most common primary liver cancer and a major public health problem worldwide. Hepatocarcinogenesis is a complex multistep process at molecular, cellular, and histologic levels with key alterations that can be revealed by noninvasive imaging modalities. Therefore, imaging techniques play pivotal roles in the detection, characterization, staging, surveillance, and prognosis evaluation of HCC. Currently, ultrasound is the first-line imaging modality for screening and surveillance purposes. While based on conclusive enhancement patterns comprising arterial phase hyperenhancement and portal venous and/or delayed phase wash-out, contrast enhanced dynamic computed tomography and magnetic resonance imaging (MRI) are the diagnostic tools for HCC without requirements for histopathologic confirmation. Functional MRI techniques, including diffusion-weighted imaging, MRI with hepatobiliary contrast agents, perfusion imaging, and magnetic resonance elastography, show promise in providing further important information regarding tumor biological behaviors. In addition, evaluation of tumor imaging characteristics, including nodule size, margin, number, vascular invasion, and growth patterns, allows preoperative prediction of tumor microvascular invasion and patient prognosis. Therefore, the aim of this article is to review the current state-of-the-art and recent advances in the comprehensive noninvasive imaging evaluation of HCC. We also provide the basic key concepts of HCC development and an overview of the current practice guidelines. PMID:29904242

  15. Non-invasive assessment of the liver using imaging

    Science.gov (United States)

    Thorling Thompson, Camilla; Wang, Haolu; Liu, Xin; Liang, Xiaowen; Crawford, Darrell H.; Roberts, Michael S.

    2016-12-01

    Chronic liver disease causes 2,000 deaths in Australia per year and early diagnosis is crucial to avoid progression to cirrhosis and end stage liver disease. There is no ideal method to evaluate liver function. Blood tests and liver biopsies provide spot examinations and are unable to track changes in function quickly. Therefore better techniques are needed. Non-invasive imaging has the potential to extract increased information over a large sampling area, continuously tracking dynamic changes in liver function. This project aimed to study the ability of three imaging techniques, multiphoton and fluorescence lifetime imaging microscopy, infrared thermography and photoacoustic imaging, in measuring liver function. Collagen deposition was obvious in multiphoton and fluorescence lifetime imaging in fibrosis and cirrhosis and comparable to conventional histology. Infrared thermography revealed a significantly increased liver temperature in hepatocellular carcinoma. In addition, multiphoton and fluorescence lifetime imaging and photoacoustic imaging could both track uptake and excretion of indocyanine green in rat liver. These results prove that non-invasive imaging can extract crucial information about the liver continuously over time and has the potential to be translated into clinic in the assessment of liver disease.

  16. Electrophysiological Source Imaging: A Noninvasive Window to Brain Dynamics.

    Science.gov (United States)

    He, Bin; Sohrabpour, Abbas; Brown, Emery; Liu, Zhongming

    2018-06-04

    Brain activity and connectivity are distributed in the three-dimensional space and evolve in time. It is important to image brain dynamics with high spatial and temporal resolution. Electroencephalography (EEG) and magnetoencephalography (MEG) are noninvasive measurements associated with complex neural activations and interactions that encode brain functions. Electrophysiological source imaging estimates the underlying brain electrical sources from EEG and MEG measurements. It offers increasingly improved spatial resolution and intrinsically high temporal resolution for imaging large-scale brain activity and connectivity on a wide range of timescales. Integration of electrophysiological source imaging and functional magnetic resonance imaging could further enhance spatiotemporal resolution and specificity to an extent that is not attainable with either technique alone. We review methodological developments in electrophysiological source imaging over the past three decades and envision its future advancement into a powerful functional neuroimaging technology for basic and clinical neuroscience applications.

  17. Nuclear imaging system

    International Nuclear Information System (INIS)

    Barrett, H.H.; Horrigan, F.A.

    1975-01-01

    This invention relates to a nuclear imaging system for mapping the source of high energy nuclear particles from a living organ which has selectively absorbed a radioactive compound by spatially coding the energy from the source in a Fresnel pattern on a detector and decoding the detector output to prouce an image of the source. The coding is produced by a Fresnel zone plate interposed between the nuclear energy source and the detector whose position is adjustable with respect to the detector to focus the slices of the nuclear source on the detector. By adjusting the zone plate to a plurality of positions, data from a plurality of cross-sectional slices are produced from which a three-dimensional image of the nuclear source may be obtained. (Patent Office Record)

  18. Nuclear imaging in pediatrics

    International Nuclear Information System (INIS)

    Siddiqui, A.R.

    1985-01-01

    The author's intent is to familiarize practicing radiologists with the technical aspects and interpretation of nuclear medicine procedures in children and to illustrate the indications for nuclear medicine procedures in pediatric problems. Pediatric doses, dosimetry, sedation, and injection techniques, organ systems, oncology and infection, testicular scanning and nuclear crystography, pediatric endocrine and skeletal systems, ventilation and perfusion imaging of both congenital and acquired pediatric disorders, cardiovascular problems, gastrointestinal, hepatobiliary, reticuloendothelial studies, and central nervous system are all topics which are included and discussed

  19. Non-invasive cardiac imaging. Spectrum, methodology, indication and interpretation

    International Nuclear Information System (INIS)

    Schaefers, Michael; Flachskampf, Frank; Sechtem, Udo; Achenbach, Stephan; Krause, Bernd J.; Schwaiger, Markus; Breithardt, Guenter

    2008-01-01

    The book contains 13 contributions concerning the following chapters: (1)methodology: echo cardiography; NMR imaging; nuclear medicine; computer tomography, (2) clinical protocols: contraction; cardiac valve function; perfusion and perfusion reserve; vitality; corona imaging; transmitters, receptors, enzymes; (3) clinic: coronary heart diseases; non-ischemic heart diseases. The appendix contains two contributions on future developments and certification/standardization

  20. Imaging in nuclear medicine

    CERN Document Server

    Hoeschen, Christoph

    2013-01-01

    This volume addresses a wide range of issues in the field of nuclear medicine imaging, with an emphasis on the latest research findings. Initial chapters set the scene by considering the role of imaging in nuclear medicine from the medical perspective and discussing the implications of novel agents and applications for imaging. The physics at the basis of the most modern imaging systems is described, and the reader is introduced to the latest advances in image reconstruction and noise correction. Various novel concepts are then discussed, including those developed within the framework of the EURATOM FP7 MADEIRA research project on the optimization of imaging procedures in order to permit a reduction in the radiation dose to healthy tissues. Advances in quality control and quality assurance are covered, and the book concludes by listing rules of thumb for imaging that will be of use to both beginners and experienced researchers.

  1. Imaging in nuclear medicine

    International Nuclear Information System (INIS)

    Giussani, Augusto; Hoeschen, Christoph

    2013-01-01

    Presents the most recent developments in nuclear medicine imaging, with emphasis on the latest research findings. Considers the latest advances in imaging systems, image reconstruction, noise correction, and quality assurance. Discusses novel concepts, including those developed within the framework of the EURATOM FP7 MADEIRA project. Lists rules of thumb for imaging of use to both beginners and experienced researchers. This volume addresses a wide range of issues in the field of nuclear medicine imaging, with an emphasis on the latest research findings. Initial chapters set the scene by considering the role of imaging in nuclear medicine from the medical perspective and discussing the implications of novel agents and applications for imaging. The physics at the basis of the most modern imaging systems is described, and the reader is introduced to the latest advances in image reconstruction and noise correction. Various novel concepts are then discussed, including those developed within the framework of the EURATOM FP7 MADEIRA research project on the optimization of imaging procedures in order to permit a reduction in the radiation dose to healthy tissues. Advances in quality control and quality assurance are covered, and the book concludes by listing rules of thumb for imaging that will be of use to both beginners and experienced researchers.

  2. Imaging in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Giussani, Augusto [BfS - Federal Office for Radiation Protection, Oberschleissheim (Germany). Dept. of Radiation Protection and Health; Hoeschen, Christoph (eds.) [Helmholtz Zentrum Muenchen - German Research Center for Environmental Health, Neuherberg (Germany). Research Unit Medical Raditation Physics and Diagnostics

    2013-08-01

    Presents the most recent developments in nuclear medicine imaging, with emphasis on the latest research findings. Considers the latest advances in imaging systems, image reconstruction, noise correction, and quality assurance. Discusses novel concepts, including those developed within the framework of the EURATOM FP7 MADEIRA project. Lists rules of thumb for imaging of use to both beginners and experienced researchers. This volume addresses a wide range of issues in the field of nuclear medicine imaging, with an emphasis on the latest research findings. Initial chapters set the scene by considering the role of imaging in nuclear medicine from the medical perspective and discussing the implications of novel agents and applications for imaging. The physics at the basis of the most modern imaging systems is described, and the reader is introduced to the latest advances in image reconstruction and noise correction. Various novel concepts are then discussed, including those developed within the framework of the EURATOM FP7 MADEIRA research project on the optimization of imaging procedures in order to permit a reduction in the radiation dose to healthy tissues. Advances in quality control and quality assurance are covered, and the book concludes by listing rules of thumb for imaging that will be of use to both beginners and experienced researchers.

  3. Nuclear imaging: Advances and trends

    International Nuclear Information System (INIS)

    Herk, G. van

    1986-01-01

    In this article, nuclear imaging instruments that are likely to be of interest to the nuclear medicine community of developing countries are emphasized. The advances, trends, developments, and future directions in the field of nuclear imaging are mentioned

  4. Nuclear magnetic resonance imaging in pharmaceutical research

    International Nuclear Information System (INIS)

    Sarkar, S.K.

    1991-01-01

    Nuclear magnetic resonance imaging has important applications in pharmaceutical research since it allows specific tissue and disease characterization in animal models noninvasively with excellent anatomical resolution and therefore provides improved ability to monitor the efficacy of novel drugs. The utility of NMR imaging in renal studies to monitor the mechanism of drug action and renal function in rats is described. The extension of the resolution of an NMR image to microscopic domain at higher magnetic field strengths and the utility of NMR microimaging in cerebrovascular and tumour metastasis studies in mice are discussed. (author). 40 refs., 14 figs

  5. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    In a method of imaging a body in which nuclear magnetic resonance is excited in a region including part of the body, and the free induction decay signal is measured, a known quantity of a material of known nuclear magnetic resonance properties, for example a bag of water, is included in the region so as to enhance the measured free induction decay signal. This then reduces the generation of noise during subsequent processing of the signal. (author)

  6. The research progress of nuclear medicine on cardiovascular molecular imaging

    International Nuclear Information System (INIS)

    Yin Xiaohua; Zhang Yongxue

    2007-01-01

    Cardiovascular molecular imaging is a rapidly evolving discipline and its clinical application is promising. Nuclear medicine is playing a leading role in this field with its special superiority of noninvasive, quantifiability, high sensitivity and specificity. It provides broad opportunities for exploring the pathophysiologic process of cardiovascular diseases and monitoring its gene therapy in the molecular level. In this review, we mainly discuss some basic knowledge on cardiovascular molecular imaging, and then focus on the applied research prospect of nuclear medicine radionuclide imaging. (authors)

  7. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    1983-06-01

    This report summarises the aspects of nuclear magnetic resonance imaging (NMRI) considered by the National Health Technology Advisory Panel and makes recommendations on its introduction in Australia with particular regard to the need for thorough evaluation of its cost effectiveness. Topics covered are: principles of the technique, equipment required, installation, costs, reliability, performance parameters, clinical indications, training and staff requirements, and safety considerations

  8. Assays for noninvasive imaging of reporter gene expression

    International Nuclear Information System (INIS)

    Gambhir, S.S.; Barrio, J.R.; Herschman, H.R.; Phelps, M.E.

    1999-01-01

    Repeated, noninvasive imaging of reporter gene expression is emerging as a valuable tool for monitoring the expression of genes in animals and humans. Monitoring of organ/cell transplantation in living animals and humans, and the assessment of environmental, behavioral, and pharmacologic modulation of gene expression in transgenic animals should soon be possible. The earliest clinical application is likely to be monitoring human gene therapy in tumors transduced with the herpes simplex virus type 1 thymidine kinase (HSV1-tk) suicide gene. Several candidate assays for imaging reporter gene expression have been studied, utilizing cytosine deaminase (CD), HSV1-tk, and dopamine 2 receptor (D2R) as reporter genes. For the HSV1-tk reporter gene, both uracil nucleoside derivatives (e.g., 5-iodo-2'-fluoro-2'-deoxy-1-β-D-arabinofuranosyl-5-iodouracil [FIAU] labeled with 124 I, 131 I ) and acycloguanosine derivatives {e.g., 8-[ 18 F]fluoro-9-[[2-hydroxy-1-(hydroxymethyl)ethoxy]methyl]guanine (8-[ 18 F]-fluoroganciclovir) ([ 18 F]FGCV), 9-[(3-[ 18 F]fluoro-1-hydroxy-2-propoxy)methyl]guanine ([ 18 F]FHPG)} have been investigated as reporter probes. For the D2R reporter gene, a derivative of spiperone {3-(2'-[ 18 F]-Fluoroethyl)spiperone ([ 18 F]FESP)} has been used with positron emission tomography (PET) imaging. In this review, the principles and specific assays for imaging reporter gene expression are presented and discussed. Specific examples utilizing adenoviral-mediated delivery of a reporter gene as well as tumors expressing reporter genes are discussed

  9. Non-invasive vascular imaging: assessing tumour vascularity

    International Nuclear Information System (INIS)

    Delorme, S.; Knopp, M.V.

    1998-01-01

    Non-invasive assessment of vascularity is a new diagnostic approach to characterise tumours. Vascular assessment is based on the pathophysiology of tumour angiogenesis and its diagnostic implications for tumour biology, prognosis and therapy response. Two current techniques investigating vascular features in addition to morphology are Doppler ultrasonography and contrast-enhanced MRI. Diagnostic differentiation has been shown to be possible with Doppler, and a high degree of observed vascularity could be linked to an aggressive course of the disease. Dynamic MRI using gadolinium chelates is already used clinically to detect and differentiate tumours. The histological correlation shows that capillary permeability is increased in malignant tumours and is the best criterion for differentiation from benign processes. Permeability and perfusion factors seem to be more diagnostic than overall vessel density. New clinical applications are currently being established for therapy monitoring. Further instrumental developments will bring harmonic imaging in Doppler, and faster imaging techniques, higher spatial resolution and novel pharmacokinetic concepts in MRI. Upcoming contrast agents for both Doppler and MRI will further improve estimation of intratumoural blood volume and vascular permeability. (orig.)

  10. Nuclear Waste Imaging and Spent Fuel Verification by Muon Tomography

    OpenAIRE

    Jonkmans, G.; Anghel, V. N. P.; Jewett, C.; Thompson, M.

    2012-01-01

    This paper explores the use of cosmic ray muons to image the contents of shielded containers and detect high-Z special nuclear materials inside them. Cosmic ray muons are a naturally occurring form of radiation, are highly penetrating and exhibit large scattering angles on high Z materials. Specifically, we investigated how radiographic and tomographic techniques can be effective for non-invasive nuclear waste characterization and for nuclear material accountancy of spent fuel inside dry stor...

  11. Computing volume potentials for noninvasive imaging of cardiac excitation.

    Science.gov (United States)

    van der Graaf, A W Maurits; Bhagirath, Pranav; van Driel, Vincent J H M; Ramanna, Hemanth; de Hooge, Jacques; de Groot, Natasja M S; Götte, Marco J W

    2015-03-01

    In noninvasive imaging of cardiac excitation, the use of body surface potentials (BSP) rather than body volume potentials (BVP) has been favored due to enhanced computational efficiency and reduced modeling effort. Nowadays, increased computational power and the availability of open source software enable the calculation of BVP for clinical purposes. In order to illustrate the possible advantages of this approach, the explanatory power of BVP is investigated using a rectangular tank filled with an electrolytic conductor and a patient specific three dimensional model. MRI images of the tank and of a patient were obtained in three orthogonal directions using a turbo spin echo MRI sequence. MRI images were segmented in three dimensional using custom written software. Gmsh software was used for mesh generation. BVP were computed using a transfer matrix and FEniCS software. The solution for 240,000 nodes, corresponding to a resolution of 5 mm throughout the thorax volume, was computed in 3 minutes. The tank experiment revealed that an increased electrode surface renders the position of the 4 V equipotential plane insensitive to mesh cell size and reduces simulated deviations. In the patient-specific model, the impact of assigning a different conductivity to lung tissue on the distribution of volume potentials could be visualized. Generation of high quality volume meshes and computation of BVP with a resolution of 5 mm is feasible using generally available software and hardware. Estimation of BVP may lead to an improved understanding of the genesis of BSP and sources of local inaccuracies. © 2014 Wiley Periodicals, Inc.

  12. 5th German cardiodiagnostic meeting 2013 with the 6th Leipzig Symposium on non-invasive cardiovascular imaging. Challenges and limit of the non-invasive cardiac imaging

    International Nuclear Information System (INIS)

    2013-01-01

    The proceedings on the German cardiodiagnostic meeting 2013 together with the 6th Leipzig Symposium on non-invasive cardiovascular imaging include abstracts concerning the following topics: Imaging in the rhythmology; adults with congenital cardiac defects; cardiac myopathies - myocarditis; cardiac valves (before and after transcutaneous valve replacement); coronary heart diseases; technical developments.

  13. Paediatric nuclear medicine imaging.

    Science.gov (United States)

    Biassoni, Lorenzo; Easty, Marina

    2017-09-01

    Nuclear medicine imaging explores tissue viability and function by using radiotracers that are taken up at cellular level with different mechanism. This imaging technique can also be used to assess blood flow and transit through tubular organs. Nuclear medicine imaging has been used in paediatrics for decades and this field is continuously evolving. The data presented comes from clinical experience and some milestone papers on the subject. Nuclear medicine imaging is well-established in paediatric nephro-urology in the context of urinary tract infection, ante-natally diagnosed hydronephrosis and other congenital renal anomalies. Also, in paediatric oncology, I-123-meta-iodobenzyl-guanidine has a key role in the management of children with neuroblastic tumours. Bone scintigraphy is still highly valuable to localize the source of symptoms in children and adolescents with bone pain when other imaging techniques have failed. Thyroid scintigraphy in neonates with congenital hypothyroidism is the most accurate imaging technique to confirm the presence of ectopic functioning thyroid tissue. Radionuclide transit studies of the gastro-intestinal tract are potentially useful in suspected gastroparesis or small bowel or colonic dysmotility. However, until now a standardized protocol and a validated normal range have not been agreed, and more work is necessary. Research is ongoing on whether magnetic resonance imaging (MRI), with its great advantage of great anatomical detail and no ionizing radiations, can replace nuclear medicine imaging in some clinical context. On the other hand, access to MRI is often difficult in many district general hospitals and general anaesthesia is frequently required, thus adding to the complexity of the examination. Patients with bone pain and no cause for it demonstrated on MRI can benefit from bone scintigraphy with single photon emission tomography and low-dose computed tomography. This technique can identify areas of mechanical stress at

  14. Risk stratification by using non-invasive radionuclide imaging in patients with unstable angina spec tories

    International Nuclear Information System (INIS)

    Saghari, M.

    2002-01-01

    Unstable angina represents a heterogeneous spectrum of clinical entities between chronic stable angina and acute myocardial infraction. Acute ischemic syndromes (including unstable angina) result from abrupt reduction in coronary flow, frequently after atherosclerotic plaque disruption and with or without associated thrombosis or vasospasm. Nuclear cardiology studies and in particular, myocardial perfusion imaging are powerful noninvasive tools for detecting and assessing the severity of acute ischemic syndromes, including unstable angina pec tories. The information derived from a nuclear cardiology study can answer unresolved clinical question and aid in subsequent patient management, specifically jeopardized myocardium detected during spontaneously occurring acute chest pain or controlled stress testing are important determinant of: 1) The need for admission to an intensive care monitoring unit 2) The need for and urgency of coronary angiography 3) The appropriate use of percutaneous or surgical coronary revascularization procedures. Extensive information suggests the stress nuclear perfusion imaging is the best validated technique for predischarge risk stratification with unstable angina patients who have been medically stabilized. Early information suggests avoidance of unecessary coronary angiography or revascularization is the cost effective strategy

  15. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods.

    Science.gov (United States)

    Barbosa, José Augusto A; Rodrigues, Alexandre B; Mota, Cleonice Carvalho C; Barbosa, Márcia M; Simões e Silva, Ana C

    2011-01-01

    Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.

  16. Molecular nuclear cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Soo; Paeng, Jin Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2004-04-01

    Molecular nuclear cardiac imaging has included Tc-99m Annexin imaging to visualize myocardial apoptosis, but is now usually associated with gene therapy and cell-based therapy. Cardiac gene therapy was not successful so far but cardiac reporter gene imaging was made possible using HSV-TK (herpes simplex virus thymidine kinase) and F-18 FHBG (fluoro-hydroxymethylbutyl guanine) or I-124 FIAU (fluoro-deoxyiodo-arabino-furanosyluracil). Gene delivery was performed by needle injection with or without catheter guidance. TK expression did not last longer than 2 weeks in myocardium. Cell-based therapy of ischemic heart or failing heart looks promising, but biodistribution and differentiation of transplanted cells are not known. Reporter genes can be transfected to the stem/progenitor cells and cells containing these genes can be transplanted to the recipients using catheter-based purging or injection. Repeated imaging should be available and if promoter are varied to let express reporter transgenes, cellular (trans)differentiation can be studied. NIS (sodium iodide symporter) or D2R receptor genes are promising in this aspect.

  17. Molecular nuclear cardiac imaging

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Paeng, Jin Chul

    2004-01-01

    Molecular nuclear cardiac imaging has included Tc-99m Annexin imaging to visualize myocardial apoptosis, but is now usually associated with gene therapy and cell-based therapy. Cardiac gene therapy was not successful so far but cardiac reporter gene imaging was made possible using HSV-TK (herpes simplex virus thymidine kinase) and F-18 FHBG (fluoro-hydroxymethylbutyl guanine) or I-124 FIAU (fluoro-deoxyiodo-arabino-furanosyluracil). Gene delivery was performed by needle injection with or without catheter guidance. TK expression did not last longer than 2 weeks in myocardium. Cell-based therapy of ischemic heart or failing heart looks promising, but biodistribution and differentiation of transplanted cells are not known. Reporter genes can be transfected to the stem/progenitor cells and cells containing these genes can be transplanted to the recipients using catheter-based purging or injection. Repeated imaging should be available and if promoter are varied to let express reporter transgenes, cellular (trans)differentiation can be studied. NIS (sodium iodide symporter) or D2R receptor genes are promising in this aspect

  18. Nuclear image display controller

    International Nuclear Information System (INIS)

    Roth, D.A.

    1985-01-01

    In a nuclear imaging system the digitized x and y coordinates of gamma ray photon emission events address memory locations corresponding to the coordinates. The respective locations are incremented each time they are addressed so at the end of a selected time or event count period the locations contain digital values or raw data corresponding to the intensity of pixels comprising an image frame. The raw data for a frame is coupled to one input of an arithmetic logic unit (ALU) whose output is coupled to a display controller memory. The output of the controller memory is coupled to another ALU input with a feedback bus and is also coupled to a further signal processing circuit which includes means for converting processed data to analog video signals for television display. The ALU is selectively controlled to let raw image data pass through to the display controllor memory or alternately to add (or subtract) raw data for the last image frame developed to the raw data for preceding frames held in the display controller to thereby produce the visual effect on the television screen of an isotope flowing through anatomy

  19. Nuclear imaging drug development tools

    International Nuclear Information System (INIS)

    Buchanan, L.; Jurek, P.; Redshaw, R.

    2007-01-01

    This article describes the development of nuclear imaging as an enabling technology in the pharmaceutical industry. Molecular imaging is maturing into an important tool with expanding applications from validating that a drug reaches the intended target through to market launch of a new drug. Molecular imaging includes anatomical imaging of organs or tissues, computerized tomography (CT), magnetic resonance imaging (MRI) and ultrasound.

  20. Magnetic resonance imaging based noninvasive measurements of brain hemodynamics in neonates

    DEFF Research Database (Denmark)

    De Vis, Jill B; Alderliesten, Thomas; Hendrikse, Jeroen

    2016-01-01

    Perinatal disturbances of brain hemodynamics can have a detrimental effect on the brain's parenchyma with consequently adverse neurodevelopmental outcome. Noninvasive, reliable tools to evaluate the neonate's brain hemodynamics are scarce. Advances in magnetic resonance imaging have provided new...

  1. In-situ Non-Invasive Imaging of Liquid-Immersed Thin Film Composite Membranes

    KAUST Repository

    Ogieglo, Wojciech; Pinnau, Ingo; Wessling, Matthias

    2017-01-01

    We present a non-invasive method to directly image liquid-immersed thin film composite membranes. The approach allows accessing information not only on the lateral distribution of the coating thickness, including variations in its swelling

  2. Non-invasive imaging of skin cancer with fluorescence lifetime imaging using two photon tomography

    Science.gov (United States)

    Patalay, Rakesh; Talbot, Clifford; Alexandrov, Yuriy; Munro, Ian; Breunig, Hans Georg; König, Karsten; Warren, Sean; Neil, Mark A. A.; French, Paul M. W.; Chu, Anthony; Stamp, Gordon W.; Dunsby, Christopher

    2011-07-01

    Multispectral fluorescence lifetime imaging (FLIM) using two photon microscopy as a non-invasive technique for the diagnosis of skin lesions is described. Skin contains fluorophores including elastin, keratin, collagen, FAD and NADH. This endogenous contrast allows tissue to be imaged without the addition of exogenous agents and allows the in vivo state of cells and tissues to be studied. A modified DermaInspect® multiphoton tomography system was used to excite autofluorescence at 760 nm in vivo and on freshly excised ex vivo tissue. This instrument simultaneously acquires fluorescence lifetime images in four spectral channels between 360-655 nm using time-correlated single photon counting and can also provide hyperspectral images. The multispectral fluorescence lifetime images were spatially segmented and binned to determine lifetimes for each cell by fitting to a double exponential lifetime model. A comparative analysis between the cellular lifetimes from different diagnoses demonstrates significant diagnostic potential.

  3. Non-invasive imaging of plant roots in different soils using magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Daniel Pflugfelder

    2017-11-01

    Full Text Available Abstract Background Root systems are highly plastic and adapt according to their soil environment. Studying the particular influence of soils on root development necessitates the adaptation and evaluation of imaging methods for multiple substrates. Non-invasive 3D root images in soil can be obtained using magnetic resonance imaging (MRI. Not all substrates, however, are suitable for MRI. Using barley as a model plant we investigated the achievable image quality and the suitability for root phenotyping of six commercially available natural soil substrates of commonly occurring soil textures. The results are compared with two artificially composed substrates previously documented for MRI root imaging. Results In five out of the eight tested substrates, barley lateral roots with diameters below 300 µm could still be resolved. In two other soils, only the thicker barley seminal roots were detectable. For these two substrates the minimal detectable root diameter was between 400 and 500 µm. Only one soil did not allow imaging of the roots with MRI. In the artificially composed substrates, soil moisture above 70% of the maximal water holding capacity (WHCmax impeded root imaging. For the natural soil substrates, soil moisture had no effect on MRI root image quality in the investigated range of 50–80% WHCmax. Conclusions Almost all tested natural soil substrates allowed for root imaging using MRI. Half of these substrates resulted in root images comparable to our current lab standard substrate, allowing root detection down to a diameter of 300 µm. These soils were used as supplied by the vendor and, in particular, removal of ferromagnetic particles was not necessary. With the characterization of different soils, investigations such as trait stability across substrates are now possible using noninvasive MRI.

  4. Molecular nuclear imaging for targeting and trafficking

    International Nuclear Information System (INIS)

    Bom, Hee Seung; Min, Jung Jun; Jeong, Hwan-Jeong

    2006-01-01

    Noninvasive molecular targeting in living subjects is highly demanded for better understanding of such diverse topics as the efficient delivery of drugs, genes, or radionuclides for the diagnosis or treatment of diseases. Progress in molecular biology, genetic engineering and polymer chemistry provides various tools to target molecules and cells in vivo. We used chitosan as a polymer, and 99m Tc as a radionuclide. We developed 99m Tc-galactosylated chitosan to target asialoglycoprotein receptors for nuclear imaging. We also developed 99m Tc-HYNIC-chitosan-transferrin to target inflammatory cells, which was more effective than 67 Ga-citrate for imaging inflammatory lesions. For an effective delivery of molecules, a longer circulation time is needed. We found that around 10% PEGylation was most effective to prolong the circulation time of liposomes for nuclear imaging of 99m Tc-HMPAO-labeled liposomes in rats. Using various characteristics of molecules, we can deliver drugs into targets more effectively. We found that 99m Tc-labeled biodegradable pullulan-derivatives are retained in tumor tissue in response to extracellular ion-strength. For the trafficking of various cells or bacteria in an intact animal, we used optical imaging techniques or radiolabeled cells. We monitored tumor-targeting bacteria by bioluminescent imaging techniques, dentritic cells by radiolabeling and neuronal stem cells by sodium-iodide symporter reporter gene imaging. In summary, we introduced recent achievements of molecular nuclear imaging technologies in targeting receptors for hepatocyte or inflammatory cells and in trafficking bacterial, immune and stem cells using molecular nuclear imaging techniques

  5. Imaging modalities for the non-invasive diagnosis of endometriosis.

    Science.gov (United States)

    Nisenblat, Vicki; Bossuyt, Patrick M M; Farquhar, Cindy; Johnson, Neil; Hull, M Louise

    2016-02-26

    About 10% of women of reproductive age suffer from endometriosis. Endometriosis is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy, the gold standard diagnostic test for endometriosis, is expensive and carries surgical risks. Currently, no non-invasive tests that can be used to accurately diagnose endometriosis are available in clinical practice. This is the first review of diagnostic test accuracy of imaging tests for endometriosis that uses Cochrane methods to provide an update on the rapidly expanding literature in this field. • To provide estimates of the diagnostic accuracy of imaging modalities for the diagnosis of pelvic endometriosis, ovarian endometriosis and deeply infiltrating endometriosis (DIE) versus surgical diagnosis as a reference standard.• To describe performance of imaging tests for mapping of deep endometriotic lesions in the pelvis at specific anatomical sites.Imaging tests were evaluated as replacement tests for diagnostic surgery and as triage tests that would assist decision making regarding diagnostic surgery for endometriosis. We searched the following databases to 20 April 2015: MEDLINE, CENTRAL, EMBASE, CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, MEDION, DARE, and PubMed. Searches were not restricted to a particular study design or language nor to specific publication dates. The search strategy incorporated words in the title, abstracts, text words across the record and medical subject headings (MeSH). We considered published peer-reviewed cross-sectional studies and randomised controlled trials of any size that included prospectively recruited women of reproductive age suspected of having one or more of the following target conditions: endometrioma, pelvic endometriosis, DIE or endometriotic lesions at specific intrapelvic anatomical locations. We included studies that compared the diagnostic test accuracy of one or more imaging modalities versus findings of surgical

  6. Imaging modalities for the non-invasive diagnosis of endometriosis

    NARCIS (Netherlands)

    Nisenblat, Vicki; Bossuyt, Patrick M. M.; Farquhar, Cindy; Johnson, Neil; Hull, M. Louise

    2016-01-01

    About 10% of women of reproductive age suffer from endometriosis. Endometriosis is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy, the gold standard diagnostic test for endometriosis, is expensive and carries surgical risks. Currently, no non-invasive tests that can

  7. Essentials of nuclear medicine imaging

    CERN Document Server

    Mettler, Fred A. Jr

    2012-01-01

    Essentials of Nuclear Medicine Imaging, by Drs. Fred A Mettler and Milton J Guiberteau, provides the practical and comprehensive guidance you need to master key nuclear imaging techniques. From physics, instrumentation, quality control, and legal requirements to hot topics such as sodium fluoride, radiopharmaceuticals, and recommended pediatric administered doses and guidelines, this sixth edition covers the fundamentals and recent developments in the practice of nuclear medicine.

  8. Nuclear imaging of the chest

    International Nuclear Information System (INIS)

    Bahk, Y.W.

    1998-01-01

    This book provides up-to-the minute information on the diagnostic nuclear imaging of chest disorders. The authors have endeavored to integrate and consolidate the many different subspecialities in order to enable a holistic understanding of chest diseases from the nuclear medicine standpoint. Highlights of the book include in addition to the cardiac scan the description of aerosol lung imaging in COPD and other important pulmonary diseases and the updates on breast and lung cancer imaging, as well as imaging of the bony thorax and esophagus. It is required reading not only for nuclear medicine practitioners and researchers but also for all interested radiologists, traumatologists, pulmonologists, oncologists and cardiologists. (orig.)

  9. Nuclear medicine imaging system

    Science.gov (United States)

    Bennett, Gerald W.; Brill, A. Bertrand; Bizais, Yves J. C.; Rowe, R. Wanda; Zubal, I. George

    1986-01-01

    A nuclear medicine imaging system having two large field of view scintillation cameras mounted on a rotatable gantry and being movable diametrically toward or away from each other is disclosed. In addition, each camera may be rotated about an axis perpendicular to the diameter of the gantry. The movement of the cameras allows the system to be used for a variety of studies, including positron annihilation, and conventional single photon emission, as well as static orthogonal dual multi-pinhole tomography. In orthogonal dual multi-pinhole tomography, each camera is fitted with a seven pinhole collimator to provide seven views from slightly different perspectives. By using two cameras at an angle to each other, improved sensitivity and depth resolution is achieved. The computer system and interface acquires and stores a broad range of information in list mode, including patient physiological data, energy data over the full range detected by the cameras, and the camera position. The list mode acquisition permits the study of attenuation as a result of Compton scatter, as well as studies involving the isolation and correlation of energy with a range of physiological conditions.

  10. Nuclear Medicine Imaging

    Science.gov (United States)

    ... necesita saber acerca de... Estudios de Imagen de Medicina Nuclear Un procedimiento de medicina nuclear se describe algunas veces como unos rayos- ... través del cuerpo del paciente. Los procedimientos de medicina nuclear utilizan pequeñas cantidades de mate- riales radiactivos, ...

  11. Non-invasive imaging of kupffer cell status using radiolabelled mannosylated albumin

    NARCIS (Netherlands)

    Mahajan, V.; Hartimath, S.; Comley, R.; Stefan-Gueldner, M.; Roth, A.; Poelstra, K.; Reker-Smit, C.; Kamps, J.; Dierckx, R.; de Vries, Erik

    2014-01-01

    Background and Aims: Kupffer cells are responsible for maintaining liver homeostasis and have a vital role in chronic hepatotoxicity and various liver diseases. Positron Imaging Tomography (PET) is a non-invasive imaging technique that allows quantification and visualization of biochemical processes

  12. Non-invasive imaging for studying anti-angiogenic therapy effects

    NARCIS (Netherlands)

    Ehling, J.; Lammers, Twan Gerardus Gertudis Maria; Kiessling, F.

    2013-01-01

    Noninvasive imaging plays an emerging role in preclinical and clinical cancer research and has high potential to improve clinical translation of new drugs. This article summarises and discusses tools and methods to image tumour angiogenesis and monitor anti-angiogenic therapy effects. In this

  13. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods

    Directory of Open Access Journals (Sweden)

    Barbosa JA

    2011-05-01

    Full Text Available José Augusto A Barbosa¹, Alexandre B Rodrigues¹, Cleonice Carvalho C Mota¹, Márcia M Barbosa², Ana C Simões e Silva¹¹Department of Pediatrics, Faculty of Medicine, Federal University of Minas Gerais (UFMG, Belo Horizonte, Minas Gerais, Brazil; ²Ecocenter, Socor Hospital, Belo Horizonte, Minas Gerais, BrazilAbstract: Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.Keywords: cardiovascular risk, endothelium dysfunction, obesity, strain and strain rate, tissue Doppler

  14. Genetic identification of Iberian rodent species using both mitochondrial and nuclear loci: application to noninvasive sampling.

    Science.gov (United States)

    Barbosa, S; Pauperio, J; Searle, J B; Alves, P C

    2013-01-01

    Species identification through noninvasive sampling is increasingly used in animal conservation genetics, given that it obviates the need to handle free-living individuals. Noninvasive sampling is particularly valuable for elusive and small species such as rodents. Although rodents are not usually assumed to be the most obvious target for conservation, of the 21 species or near-species present in Iberia, three are considered endangered and declining, while several others are poorly studied. Here, we develop a genetic tool for identifying all rodent species in Iberia by noninvasive genetic sampling. To achieve this purpose, we selected one mitochondrial gene [cytochrome b (cyt-b)] and one nuclear gene [interphotoreceptor retinoid-binding protein (IRBP)], which we first sequenced using tissue samples. Both genes allow for the phylogenetic distinction of all species except the sibling species Microtus lusitanicus and Microtus duodecimcostatus. Overall, cyt-b showed higher resolution than IRBP, revealing a clear barcoding gap. To allow these markers to be applied to noninvasive samples, we selected a short highly diagnostic fragment from each gene, which we used to obtain sequences from faeces and bones from owl pellets. Amplification success for the cyt-b and IRBP fragment was 85% and 43% in faecal and 88% and 64% in owl-pellet DNA extractions, respectively. The method allows the unambiguous identification of the great majority of Iberian rodent species from noninvasive samples, with application in studies of distribution, spatial ecology and population dynamics, and for conservation. © 2012 Blackwell Publishing Ltd.

  15. Images of nuclear power plants

    International Nuclear Information System (INIS)

    Hashiguchi, Katsuhisa; Misumi, Jyuji; Yamada, Akira; Sakurai, Yukihiro; Seki, Fumiyasu; Shinohara, Hirofumi; Misumi, Emiko; Kinjou, Akira; Kubo, Tomonori.

    1995-01-01

    This study was conducted to check and see, using Hayashi's quantification method III, whether or not the respondents differed in their images of a nuclear power plant, depending on their demographic variables particularly occupations. In our simple tabulation, we compared subject groups of nuclear power plant employees with general citizens, nurses and students in terms of their images of a nuclear power plant. The results were that while the nuclear power plant employees were high in their evaluations of facts about a nuclear power plant and in their positive images of a nuclear power plant, general citizens, nurses and students were overwhelmingly high in their negative images of a nuclear power plant. In our analysis on category score by means of the quantification method III, the first correlation axis was the dimension of 'safety'-'danger' and the second correlation axis was the dimension of 'subjectivity'-'objectivity', and that the first quadrant was the area of 'safety-subjectivity', the second quadrant was the area of 'danger-subjectivity', the third quadrant as the area of 'danger-objectivity', and the forth quadrant was the area of 'safety-objectivity'. In our analysis of sample score, 16 occupation groups was compared. As a result, it was found that the 16 occupation groups' images of a nuclear power plant were, in the order of favorableness, (1) section chiefs in charge, maintenance subsection chiefs, maintenance foremen, (2) field leaders from subcontractors, (3) maintenance section members, operation section members, (4) employees of those subcontractors, (5) general citizens, nurses and students. On the 'safety-danger' dimension, nuclear power plant workers on the one hand and general citizens, nurses and students on the other were clearly divided in terms of their images of a nuclear power plant. Nuclear power plant workers were concentrated in the area of 'safety' and general citizens, nurses and students in the area of 'danger'. (J.P.N.)

  16. Molecular–Genetic Imaging: A Nuclear Medicine–Based Perspective

    Directory of Open Access Journals (Sweden)

    Ronald G. Blasberg

    2002-07-01

    Full Text Available Molecular imaging is a relatively new discipline, which developed over the past decade, initially driven by in situ reporter imaging technology. Noninvasive in vivo molecular–genetic imaging developed more recently and is based on nuclear (positron emission tomography [PET], gamma camera, autoradiography imaging as well as magnetic resonance (MR and in vivo optical imaging. Molecular–genetic imaging has its roots in both molecular biology and cell biology, as well as in new imaging technologies. The focus of this presentation will be nuclear-based molecular–genetic imaging, but it will comment on the value and utility of combining different imaging modalities. Nuclear-based molecular imaging can be viewed in terms of three different imaging strategies: (1 “indirect” reporter gene imaging; (2 “direct” imaging of endogenous molecules; or (3 “surrogate” or “bio-marker” imaging. Examples of each imaging strategy will be presented and discussed. The rapid growth of in vivo molecular imaging is due to the established base of in vivo imaging technologies, the established programs in molecular and cell biology, and the convergence of these disciplines. The development of versatile and sensitive assays that do not require tissue samples will be of considerable value for monitoring molecular–genetic and cellular processes in animal models of human disease, as well as for studies in human subjects in the future. Noninvasive imaging of molecular–genetic and cellular processes will complement established ex vivo molecular–biological assays that require tissue sampling, and will provide a spatial as well as a temporal dimension to our understanding of various diseases and disease processes.

  17. Images compression in nuclear medicine

    International Nuclear Information System (INIS)

    Rebelo, M.S.; Furuie, S.S.; Moura, L.

    1992-01-01

    The performance of two methods for images compression in nuclear medicine was evaluated. The LZW precise, and Cosine Transformed, approximate, methods were analyzed. The results were obtained, showing that the utilization of approximated method produced images with an agreeable quality for visual analysis and compression rates, considerably high than precise method. (C.G.C.)

  18. Historic images in nuclear medicine

    DEFF Research Database (Denmark)

    Hess, Søren; Høilund-Carlsen, Poul Flemming; Alavi, Abass

    2014-01-01

    In 1976, 2 major molecular imaging events coincidentally took place: Clinical Nuclear Medicine was first published in June, and in August researchers at the Hospital of the University of Pennsylvania created the first images in humans with F-FDG. FDG was initially developed as part of an evolution...... set in motion by fundamental research studies with positron-emitting tracers in the 1950s by Michel Ter-Pegossian and coworkers at the Washington University. Today, Clinical Nuclear Medicine is a valued scientific contributor to the molecular imaging community, and FDG PET is considered the backbone...

  19. Non-invasive vascular imaging in perforator flap surgery

    International Nuclear Information System (INIS)

    Saba, Luca; Piga, Mario; Atzeni, Matteo; Ribuffo, Diego; Rozen, Warren Matthew; Alonso-Burgos, Alberto; Bura, Raffaella

    2013-01-01

    Preoperative imaging using a range of imaging modalities has become increasingly popular for preoperative planning in plastic surgery, in particular in perforator flap surgery. Modalities in this role include ultrasound (US), magnetic resonance angiography (MRA), and computed tomographic angiography (CTA). The evidence for the use of these techniques has been reported in only a handful of studies. In this paper we conducted a non-systematic review of the literature to establish the role for each of these modalities. The role of state-of-the-art vascular imaging as an application in perforator flap surgery is thus offered

  20. Validity of bioluminescence measurements for noninvasive in vivo imaging of tumor load in small animals

    NARCIS (Netherlands)

    Klerk, Clara P. W.; Overmeer, Renée M.; Niers, Tatjana M. H.; Versteeg, Henri H.; Richel, Dick J.; Buckle, Tessa; van Noorden, Cornelis J. F.; van Tellingen, Olaf

    2007-01-01

    A relatively new strategy to longitudinally monitor tumor load in intact animals and the effects of therapy is noninvasive bioluminescence imaging (BLI). The validity of BLI for quantitative assessment of tumor load in small animals is critically evaluated in the present review. Cancer cells are

  1. A Noninvasive Imaging Approach to Understanding Speech Changes following Deep Brain Stimulation in Parkinson's Disease

    Science.gov (United States)

    Narayana, Shalini; Jacks, Adam; Robin, Donald A.; Poizner, Howard; Zhang, Wei; Franklin, Crystal; Liotti, Mario; Vogel, Deanie; Fox, Peter T.

    2009-01-01

    Purpose: To explore the use of noninvasive functional imaging and "virtual" lesion techniques to study the neural mechanisms underlying motor speech disorders in Parkinson's disease. Here, we report the use of positron emission tomography (PET) and transcranial magnetic stimulation (TMS) to explain exacerbated speech impairment following…

  2. Noninvasive Quantification of Retinal Microglia Using Widefield Autofluorescence Imaging.

    Science.gov (United States)

    Kokona, Despina; Schneider, Nadia; Giannakaki-Zimmermann, Helena; Jovanovic, Joel; Ebneter, Andreas; Zinkernagel, Martin

    2017-04-01

    To validate widefield autofluorescence (AF) in vivo imaging of the retina in mice expressing green fluorescent protein (gfp) in microglia, and to monitor retinal microglia reconstitution in vivo after lethal irradiation and bone marrow transplantation. Transgenic Cx3cr1gfp/gfp and wildtype Balb/c mice were used in this study. A confocal scanning laser ophthalmoscope was used for AF imaging with a 55° and a widefield 102° lens. Intrasession reproducibility was assessed for each lens. To investigate reconstitution in vivo, bone marrow from Cx3cr1gfp/gfp mice was used to rescue lethally irradiated wildtype mice. Data were compared to confocal microscopy of retinal flat mounts. Both the 55° and the 102° lens produced high resolution images of retinal microglia with similar microglia density. However, compared to the 55° lens, the widefield 102° lens captured approximately 3.6 times more microglia cells (1515 ± 123 cells versus 445 ± 76 cells [mean ± SD], for 102° and 55°, respectively, P < 0.001). No statistical difference in the number of gfp positive cells within corresponding areas was observed within the same imaging session. Imaging of microglia reconstitution showed a similar time course compared to flat mount preparations with an excellent correlation between microglia cell numbers in AF and gfp-stained flat mounts (R = 0.92, P < 0.0001). Widefield AF imaging of mice with gfp expressing microglia can be used to quantify retinal microglia. In vivo microglia counts corresponded very well with ex vivo counts on retinal flat mounts. As such, AF imaging can largely replace ex vivo quantification.

  3. Non-invasive imaging using reporter genes altering cellular water permeability

    Science.gov (United States)

    Mukherjee, Arnab; Wu, Di; Davis, Hunter C.; Shapiro, Mikhail G.

    2016-12-01

    Non-invasive imaging of gene expression in live, optically opaque animals is important for multiple applications, including monitoring of genetic circuits and tracking of cell-based therapeutics. Magnetic resonance imaging (MRI) could enable such monitoring with high spatiotemporal resolution. However, existing MRI reporter genes based on metalloproteins or chemical exchange probes are limited by their reliance on metals or relatively low sensitivity. Here we introduce a new class of MRI reporters based on the human water channel aquaporin 1. We show that aquaporin overexpression produces contrast in diffusion-weighted MRI by increasing tissue water diffusivity without affecting viability. Low aquaporin levels or mixed populations comprising as few as 10% aquaporin-expressing cells are sufficient to produce MRI contrast. We characterize this new contrast mechanism through experiments and simulations, and demonstrate its utility in vivo by imaging gene expression in tumours. Our results establish an alternative class of sensitive, metal-free reporter genes for non-invasive imaging.

  4. An embedded system for image segmentation and multimodal registration in noninvasive skin cancer screening.

    Science.gov (United States)

    Diaz, Silvana; Soto, Javier E; Inostroza, Fabian; Godoy, Sebastian E; Figueroa, Miguel

    2017-07-01

    We present a heterogeneous architecture for image registration and multimodal segmentation on an embedded system for noninvasive skin cancer screening. The architecture combines Otsu thresholding and the random walker algorithm to perform image segmentation, and features a hardware implementation of the Harris corner detection algorithm to perform region-of-interest detection and image registration. Running on a Xilinx XC7Z020 reconfigurable system-on-a-chip, our prototype computes the initial segmentation of a 400×400-pixel region of interest in the visible spectrum in 12.1 seconds, and registers infrared images against this region at 540 frames per second, while consuming 1.9W.

  5. NANOPARTICLES IN NUCLEAR IMAGING

    Directory of Open Access Journals (Sweden)

    Dr. Vicky V Mody PhD

    2011-01-01

    Full Text Available The present review article summarizes the current state radiolabeled nanoparticles for molecular imaging applications mainly targeting cancer. Due to their enormous flexibility, and versatility the radiolabeled nanoparticles have shown their potential in the diagnosis and therapy. As the matter of fact, these radiolabeled imaging agents enable the visualization of the cellular function and the follow-up of the molecular process in living organisms. Moreover, the rapidly advancing field of nanotechnology has provided various innovative radionuclides and delivery systems, such as liposomes, magnetic agents, polymers, dendrimers, quantum dots, and carbon nanotubes to cope up with the hurdles which have been posed by various disease states.

  6. Noninvasive perfusion imaging of human brain tumors with EPISTAR

    Energy Technology Data Exchange (ETDEWEB)

    Gaa, J. [Department of Radiology, AN-234, MRI, Beth Israel Hospital, Boston, MA 02215 (United States); Warach, S. [Department of Radiology, AN-234, MRI, Beth Israel Hospital, Boston, MA 02215 (United States); Wen, P. [Department of Neurology, Brigham and Womens Hospital, Harvard Medical School, Boston, MA (United States); Thangaraj, V. [Department of Radiology, AN-234, MRI, Beth Israel Hospital, Boston, MA 02215 (United States); Wielopolski, P. [Department of Radiology, AN-234, MRI, Beth Israel Hospital, Boston, MA 02215 (United States); Edelman, R.R. [Department of Radiology, AN-234, MRI, Beth Israel Hospital, Boston, MA 02215 (United States)

    1996-08-01

    A total of 17 patients with histologically proven diagnoses of low-grade astrocytoma (n = 4), high-grade astrocytoma (n = 8), lymphoma (n = 3), and meningioma (n = 2) were examined by using EPISTAR MR imaging. Meningiomas had the highest EPISTAR tumor/white matter contrast and low-grade astrocytomas and lymphomas the lowest. High-grade astrocytomas demonstrated elevated EPISTAR signal with marked regional heterogeneity. There was agreement between tumor vascularity by SPECT and EPISTAR in the five cases where both were done. Our results show that tumor vascularity can be assessed qualitatively by using EPISTAR without the need for contrast medium injection. (orig.). With 5 figs.

  7. Nuclear imaging in epilepsy

    International Nuclear Information System (INIS)

    Chun, Kyung Ah

    2007-01-01

    Correct localization of epileptogenic zone is important for the successful epilepsy surgery. Both ictal perfusion single photon emission computed tomography (SPECT) and interictal F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) can provide useful information in the presurgical localization of intractable partial epilepsy. These imaging modalities have excellent diagnostic sensitivity in medial temporal lobe epilepsy and provide good presurgical information in neocortical epilepsy. Also provide functional information about cellular functions to better understand the neurobiology of epilepsy and to better define the ictal onset zone, symptomatogenic zone, propagation pathways, functional deficit zone and surround inhibition zones. Multimodality imaging and developments in analysis methods of ictal perfusion SPECT and new PET ligand other than FDG help to better define the localization

  8. Nuclear imaging in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Kyung Ah [Yeungnam University Hospital, Daegu (Korea, Republic of)

    2007-04-15

    Correct localization of epileptogenic zone is important for the successful epilepsy surgery. Both ictal perfusion single photon emission computed tomography (SPECT) and interictal F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) can provide useful information in the presurgical localization of intractable partial epilepsy. These imaging modalities have excellent diagnostic sensitivity in medial temporal lobe epilepsy and provide good presurgical information in neocortical epilepsy. Also provide functional information about cellular functions to better understand the neurobiology of epilepsy and to better define the ictal onset zone, symptomatogenic zone, propagation pathways, functional deficit zone and surround inhibition zones. Multimodality imaging and developments in analysis methods of ictal perfusion SPECT and new PET ligand other than FDG help to better define the localization.

  9. 2017 multimodality appropriate use criteria for noninvasive cardiac imaging: Export consensus of the Asian society of cardiovascular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Kyong Min Sarah [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Jeong A [Dept. of Radiology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang (Korea, Republic of); Choe, Yeon Hyeon [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); and others

    2017-11-15

    In 2010, the Asian Society of Cardiovascular Imaging (ASCI) provided recommendations for cardiac CT and MRI, and this document reflects an update of the 2010 ASCI appropriate use criteria (AUC). In 2016, the ASCI formed a new working group for revision of AUC for noninvasive cardiac imaging. A major change that we made in this document is the rating of various noninvasive tests (exercise electrocardiogram, echocardiography, positron emission tomography, single-photon emission computed tomography, radionuclide imaging, cardiac magnetic resonance, and cardiac computed tomography/angiography), compared side by side for their applications in various clinical scenarios. Ninety-five clinical scenarios were developed from eight selected pre-existing guidelines and classified into four sections as follows: 1) detection of coronary artery disease, symptomatic or asymptomatic; 2) cardiac evaluation in various clinical scenarios; 3) use of imaging modality according to prior testing; and 4) evaluation of cardiac structure and function. The clinical scenarios were scored by a separate rating committee on a scale of 1–9 to designate appropriate use, uncertain use, or inappropriate use according to a modified Delphi method. Overall, the AUC ratings for CT were higher than those of previous guidelines. These new AUC provide guidance for clinicians choosing among available testing modalities for various cardiac diseases and are also unique, given that most previous AUC for noninvasive imaging include only one imaging technique. As cardiac imaging is multimodal in nature, we believe that these AUC will be more useful for clinical decision making.

  10. Non-invasive nuclear device for communicating pressure inside a body to the exterior thereof

    International Nuclear Information System (INIS)

    Fleischmann, L.W.; Meyer, G.A.; Hittman, F.; Lyon, W.C.; Hayes, W.H. Jr.

    1979-01-01

    The need for a non-invasive technique for measuring the pressure in body cavities of animals or humans is recognized as highly desirable for continuous or intermittent monitoring of body conditions. The non-invasive nuclear device of the present invention is fully implantable and is fully capable of communicating pressure inside a body to the exterior to allow readout non-invasively. In its preferred form, the invention includes a housing for subcutaneous implantation with the radioactive source. An urging means such as a bellows is provided in the housing interior. The fluid pressure from a fluid pressure sensing device within the body is transmitted to the housing interior by means of a pressure-limiting fluid through a conduit. This causes the radioactive source to move against the force out of the initial or repose shielded relationship causing a proportional increase in pressure in the body portion being monitored. The radioactive output from the radioactive source corresponds to the magnitude of the pressure within the body. The housing may be securely mounted on a supporting portion of the body and the mounting serves as a radiation shield for the body. (JTA)

  11. Noninvasive optical imaging of resistance training adaptations in human muscle

    Science.gov (United States)

    Warren, Robert V.; Cotter, Joshua; Ganesan, Goutham; Le, Lisa; Agustin, Janelle P.; Duarte, Bridgette; Cutler, Kyle; O'Sullivan, Thomas; Tromberg, Bruce J.

    2017-12-01

    A quantitative and dynamic analysis of skeletal muscle structure and function can guide training protocols and optimize interventions for rehabilitation and disease. While technologies exist to measure body composition, techniques are still needed for quantitative, long-term functional imaging of muscle at the bedside. We evaluate whether diffuse optical spectroscopic imaging (DOSI) can be used for long-term assessment of resistance training (RT). DOSI measures of tissue composition were obtained from 12 adults before and after 5 weeks of training and compared to lean mass fraction (LMF) from dual-energy X-ray absorptiometry (DXA). Significant correlations were detected between DXA LMF and DOSI-measured oxy-hemo/myoglobin, deoxy-hemo/myoglobin, total-hemo/myoglobin, water, and lipid. RT-induced increases of ˜6% in oxy-hemo/myoglobin (3.4±1.0 μM, p=0.00314) and total-hemo/myoglobin (4.9±1.1 μM, p=0.00024) from the medial gastrocnemius were detected with DOSI and accompanied by ˜2% increases in lean soft tissue mass (36.4±12.4 g, p=0.01641) and ˜60% increases in 1 rep-max strength (41.5±6.2 kg, p = 1.9E-05). DOSI measures of vascular and/or muscle changes combined with correlations between DOSI and DXA suggest that quantitative diffuse optical methods can be used to evaluate body composition, provide feedback on long-term interventions, and generate new insight into training-induced muscle adaptations.

  12. Non-invasive imaging of epileptic seizures in vivo using photoacoustic tomography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Qizhi; Carney, Paul R; Yuan Zhen; Jiang Huabei [J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611 (United States); Liu Zhao [Department of Pediatrics, Division of Pediatric Neurology, University of Florida, Gainesville, FL 32610 (United States); Chen Huanxin; Roper, Steven N [Department of Neurosurgery, University of Florida, Gainesville, FL 32610-0265 (United States)], E-mail: hjiang@bme.ufl.edu

    2008-04-07

    Non-invasive laser-induced photoacoustic tomography (PAT) is an emerging imaging modality that has the potential to image the dynamic function of the brain due to its unique ability of imaging biological tissues with high optical contrast and ultrasound resolution. Here we report the first application of our finite-element-based PAT for imaging of epileptic seizures in an animal model. In vivo photoacoustic images were obtained in rats with focal seizures induced by microinjection of bicuculline, a GABA{sub A} antagonist, into the neocortex. The seizure focus was accurately localized by PAT as confirmed with gold-standard electroencephalogram (EEG). Compared to the existing neuroimaging modalities, PAT not only has the unprecedented advantage of high spatial and temporal resolution in a single imaging modality, but also is portable and low in cost, making it possible to bring brain imaging to the bedside.

  13. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  14. Peering beneath the surface: novel imaging techniques to noninvasively select gametes and embryos for ART.

    Science.gov (United States)

    Jasensky, Joshua; Swain, Jason E

    2013-10-01

    Embryo imaging has long been a critical tool for in vitro fertilization laboratories, aiding in morphological assessment of embryos, which remains the primary tool for embryo selection. With the recent emergence of clinically applicable real-time imaging systems to assess embryo morphokinetics, a renewed interest has emerged regarding noninvasive methods to assess gamete and embryo development as a means of inferring quality. Several studies exist that utilize novel imaging techniques to visualize or quantify intracellular components of gametes and embryos with the intent of correlating localization of organelles or molecular constitution with quality or outcome. However, the safety of these approaches varies due to the potential detrimental impact of light exposure or other variables. Along with complexity of equipment and cost, these drawbacks currently limit clinical application of these novel microscopes and imaging techniques. However, as evidenced by clinical incorporation of some real-time imaging devices as well as use of polarized microscopy, some of these imaging approaches may prove to be useful. This review summarizes the existing literature on novel imaging approaches utilized to examine gametes and embryos. Refinement of some of these imaging systems may permit clinical application and serve as a means to offer new, noninvasive selection tools to improve outcomes for various assisted reproductive technology procedures.

  15. Nuclear magnetic resonance imaging of the heart

    International Nuclear Information System (INIS)

    Smolorz, J.; Linden, A.; Schicha, H.; Sechtem, U.

    1988-01-01

    NMR imaging is a noninvasive technique that has been shown to provide high-quality images of the heart. Due to the signal characteristics of flowing blood, inherent contrast between blood pool and myocardium is achieved without the use of contrast media. This paper briefly describes technical aspects of NMR imaging of the heart, normal cardiovascular anatomy, applications of the technique in patients with ischemic heart disease, and the potential of NMR imaging for functional studies in various forms of heart disease. (orig.)

  16. Noninvasive imaging systems for gametes and embryo selection in IVF programs: a review.

    Science.gov (United States)

    Omidi, Marjan; Faramarzi, Azita; Agharahimi, Azam; Khalili, Mohammad Ali

    2017-09-01

    Optimizing the efficiency of the in vitro fertilization procedure by improving pregnancy rates and reducing the risks of multiple pregnancies simultaneously are the primary goals of the current assisted reproductive technology program. With the move to single embryo transfers, the need for more cost-effective and noninvasive methods for embryo selection prior to transfer is paramount. These aims require advancement in a more acquire gametes/embryo testing and selection procedures using high-tech devices. Therefore, the aim of the present review is to evaluate the efficacy of noninvasive imaging systems in the current literatures, focusing on the potential clinical application in infertile patients undergoing assisted reproductive technology treatments. In this regards, three advanced imaging systems of motile sperm organelle morphology examination, polarization microscopy and time-lapse monitoring for the best selection of the gametes and preimplantation embryos are introduced in full. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  17. (19)F-heptuloses as tools for the non-invasive imaging of GLUT2-expressing cells

    DEFF Research Database (Denmark)

    Malaisse, Willy J; Zhang, Ying; Louchami, Karim

    2012-01-01

    Suitable analogs of d-mannoheptulose are currently considered as possible tools for the non-invasive imaging of pancreatic islet insulin-producing cells. Here, we examined whether (19)F-heptuloses could be used for non-invasive imaging of GLUT2-expressing cells. After 20 min incubation, the uptake......-mannoheptulose in inhibiting insulin release. The 1-deoxy-1-fluoro-d-mannoheptulose and 3-deoxy-3-fluoro-d-mannoheptulose only marginally affected INS-1 cell viability. These findings are compatible with the view that selected (19)F-heptuloses may represent suitable tools for the non-invasive imaging of hepatocytes...

  18. Non-invasive imaging of zebrafish with spinal deformities using optical coherence tomography: a preliminary study

    Science.gov (United States)

    Bernstein, Liane; Beaudette, Kathy; Patten, Kessen; Beaulieu-Ouellet, Émilie; Strupler, Mathias; Moldovan, Florina; Boudoux, Caroline

    2013-03-01

    A zebrafish model has recently been introduced to study various genetic mutations that could lead to spinal deformities such as scoliosis. However, current imaging techniques make it difficult to perform longitudinal studies of this condition in zebrafish, especially in the early stages of development. The goal of this project is to determine whether optical coherence tomography (OCT) is a viable non-invasive method to image zebrafish exhibiting spinal deformities. Images of both live and fixed malformed zebrafish (5 to 21 days postfertilization) as well as wild-type fish (5 to 29 days postfertilization) were acquired non-invasively using a commercial SD-OCT system, with a laser source centered at 930nm (λ=100nm), permitting axial and lateral resolutions of 7 and 8μm respectively. Using two-dimensional images and three-dimensional reconstructions, it was possible to identify the malformed notochord as well as deformities in other major organs at different stages of formation. Visualization of the notochord was facilitated with the development of a segmentation algorithm. OCT images were compared to HE histological sections and images obtained by calcein staining. Because of the possibility of performing longitudinal studies on a same fish and reducing image processing time as compared with staining techniques and histology, the use of OCT could facilitate phenotypic characterization in studying genetic factors leading to spinal deformities in zebrafish and could eventually contribute to the identification of the genetic causes of spinal deformities such as scoliosis.

  19. Non-Invasive Imaging Method of Microwave Near Field Based on Solid State Quantum Sensing

    OpenAIRE

    Yang, Bo; Du, Guanxiang; Dong, Yue; Liu, Guoquan; Hu, Zhenzhong; Wang, Yongjin

    2018-01-01

    In this paper, we propose a non-invasive imaging method of microwave near field using a diamond containing nitrogen-vacancy centers. We applied synchronous pulsed sequence combined with charge coupled device camera to measure the amplitude of the microwave magnetic field. A full reconstruction formulation of the local field vector, including the amplitude and phase, is developed by measuring both left and right circular polarizations along the four nitrogen-vacancy axes. Compared to the raste...

  20. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  1. Noninvasive three-dimensional live imaging methodology for the spindles at meiosis and mitosis

    Science.gov (United States)

    Zheng, Jing-gao; Huo, Tiancheng; Tian, Ning; Chen, Tianyuan; Wang, Chengming; Zhang, Ning; Zhao, Fengying; Lu, Danyu; Chen, Dieyan; Ma, Wanyun; Sun, Jia-lin; Xue, Ping

    2013-05-01

    The spindle plays a crucial role in normal chromosome alignment and segregation during meiosis and mitosis. Studying spindles in living cells noninvasively is of great value in assisted reproduction technology (ART). Here, we present a novel spindle imaging methodology, full-field optical coherence tomography (FF-OCT). Without any dye labeling and fixation, we demonstrate the first successful application of FF-OCT to noninvasive three-dimensional (3-D) live imaging of the meiotic spindles within the mouse living oocytes at metaphase II as well as the mitotic spindles in the living zygotes at metaphase and telophase. By post-processing of the 3-D dataset obtained with FF-OCT, the important morphological and spatial parameters of the spindles, such as short and long axes, spatial localization, and the angle of meiotic spindle deviation from the first polar body in the oocyte were precisely measured with the spatial resolution of 0.7 μm. Our results reveal the potential of FF-OCT as an imaging tool capable of noninvasive 3-D live morphological analysis for spindles, which might be useful to ART related procedures and many other spindle related studies.

  2. New perspectives in nuclear imaging

    International Nuclear Information System (INIS)

    Wagner, H.N. Jr.

    1981-01-01

    In nuclear medicine, biodistribution is studied by quantitative nuclear imaging; chemistry is translated into radio-pharmacology; physics into instrumentation; and biology into physiology. Nuclear medicine can be thought of as applied physiology and physiological chemistry. The modern nuclear chemist is concerned with molecules, with relating chemical structure to biological distributions, as for iminodiacetate compounds. Using mixed ligand analysis, the hepatobiliary agent, HIDA, developed by Loberg, proved an anionic bis-complex with a charge of minus one. Further studies elsewhere showed that the co-ordination number of technetium was 5 and that an oxo-oxygen was in the apical position. From a series of analogues the amount of the complexes excreted in the bile was found to be directly proportional to the natural log of the molecular weight to charge ratio. The trend is towards the synthesis of labelled compounds whose biodistribution depends on their chemical interaction with structurally specific binding sites, i.e. receptors, enzymes or binding sites of active transport systems. Other examples include amino acids for pancreatic imaging; deoxyglucose for studies of regional brain and heart metabolism; fatty acids for studies of the heart; steroid hormones for breast tumours; and muscarinic compounds for study of the cholinergic system of the heart. Most of these compounds are labelled with 11 C, 18 F or 13 N, available only from cyclotrons, but the extension to the more widely available 123 I and sup(99m)Tc is also proceeding rapidly, stimulated chiefly by the success with the positron-emitting compounds. Advances in nuclear imaging include the development of both positron and single photon emission tomography. Biodistribution studies in man permit measurement of regional as well as global function. Improved perception is being augmented by improved quantification and automation

  3. Noninvasive mapping of water diffusional exchange in the human brain using filter-exchange imaging.

    Science.gov (United States)

    Nilsson, Markus; Lätt, Jimmy; van Westen, Danielle; Brockstedt, Sara; Lasič, Samo; Ståhlberg, Freddy; Topgaard, Daniel

    2013-06-01

    We present the first in vivo application of the filter-exchange imaging protocol for diffusion MRI. The protocol allows noninvasive mapping of the rate of water exchange between microenvironments with different self-diffusivities, such as the intracellular and extracellular spaces in tissue. Since diffusional water exchange across the cell membrane is a fundamental process in human physiology and pathophysiology, clinically feasible and noninvasive imaging of the water exchange rate would offer new means to diagnose disease and monitor treatment response in conditions such as cancer and edema. The in vivo use of filter-exchange imaging was demonstrated by studying the brain of five healthy volunteers and one intracranial tumor (meningioma). Apparent exchange rates in white matter range from 0.8±0.08 s(-1) in the internal capsule, to 1.6±0.11 s(-1) for frontal white matter, indicating that low values are associated with high myelination. Solid tumor displayed values of up to 2.9±0.8 s(-1). In white matter, the apparent exchange rate values suggest intra-axonal exchange times in the order of seconds, confirming the slow exchange assumption in the analysis of diffusion MRI data. We propose that filter-exchange imaging could be used clinically to map the water exchange rate in pathologies. Filter-exchange imaging may also be valuable for evaluating novel therapies targeting the function of aquaporins. Copyright © 2012 Wiley Periodicals, Inc.

  4. Noninvasive Multimodal Imaging to Predict Recovery of Locomotion after Extended Limb Ischemia.

    Directory of Open Access Journals (Sweden)

    Jason S Radowsky

    Full Text Available Acute limb ischemia is a common cause of morbidity and mortality following trauma both in civilian centers and in combat related injuries. Rapid determination of tissue viability and surgical restoration of blood flow are desirable, but not always possible. We sought to characterize the response to increasing periods of hind limb ischemia in a porcine model such that we could define a period of critical ischemia (the point after which irreversible neuromuscular injury occurs, evaluate non-invasive methods for characterizing that ischemia, and establish a model by which we could predict whether or not the animal's locomotion would return to baselines levels post-operatively. Ischemia was induced by either application of a pneumatic tourniquet or vessel occlusion (performed by clamping the proximal iliac artery and vein at the level of the inguinal ligament. The limb was monitored for the duration of the procedure with both 3-charge coupled device (3CCD and infrared (IR imaging for tissue oxygenation and perfusion, respectively. The experimental arms of this model are effective at inducing histologically evident muscle injury with some evidence of expected secondary organ damage, particularly in animals with longer ischemia times. Noninvasive imaging data shows excellent correlation with post-operative functional outcomes, validating its use as a non-invasive means of viability assessment, and directly monitors post-occlusive reactive hyperemia. A classification model, based on partial-least squares discriminant analysis (PLSDA of imaging variables only, successfully classified animals as "returned to normal locomotion" or "did not return to normal locomotion" with 87.5% sensitivity and 66.7% specificity after cross-validation. PLSDA models generated from non-imaging data were not as accurate (AUC of 0.53 compared the PLSDA model generated from only imaging data (AUC of 0.76. With some modification, this limb ischemia model could also serve as a

  5. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  6. Development of Noninvasive Classification Methods for Different Roasting Degrees of Coffee Beans Using Hyperspectral Imaging

    Science.gov (United States)

    Chu, Bingquan; Yu, Keqiang; Zhao, Yanru

    2018-01-01

    This study aimed to develop an approach for quickly and noninvasively differentiating the roasting degrees of coffee beans using hyperspectral imaging (HSI). The qualitative properties of seven roasting degrees of coffee beans (unroasted, light, moderately light, light medium, medium, moderately dark, and dark) were assayed, including moisture, crude fat, trigonelline, chlorogenic acid, and caffeine contents. These properties were influenced greatly by the respective roasting degree. Their hyperspectral images (874–1734 nm) were collected using a hyperspectral reflectance imaging system. The spectra of the regions of interest were manually extracted from the HSI images. Then, principal components analysis was employed to compress the spectral data and select the optimal wavelengths based on loading weight analysis. Meanwhile, the random frog (RF) methodology and the successive projections algorithm were also adopted to pick effective wavelengths from the spectral data. Finally, least squares support vector machine (LS-SVM) was utilized to establish discriminative models using spectral reflectance and corresponding labeled classes for each degree of roast sample. The results showed that the LS-SVM model, established by the RF selecting method, with eight wavelengths performed very well, achieving an overall classification accuracy of 90.30%. In conclusion, HSI was illustrated as a potential technique for noninvasively classifying the roasting degrees of coffee beans and might have an important application for the development of nondestructive, real-time, and portable sensors to monitor the roasting process of coffee beans. PMID:29671781

  7. Development of Noninvasive Classification Methods for Different Roasting Degrees of Coffee Beans Using Hyperspectral Imaging.

    Science.gov (United States)

    Chu, Bingquan; Yu, Keqiang; Zhao, Yanru; He, Yong

    2018-04-19

    This study aimed to develop an approach for quickly and noninvasively differentiating the roasting degrees of coffee beans using hyperspectral imaging (HSI). The qualitative properties of seven roasting degrees of coffee beans (unroasted, light, moderately light, light medium, medium, moderately dark, and dark) were assayed, including moisture, crude fat, trigonelline, chlorogenic acid, and caffeine contents. These properties were influenced greatly by the respective roasting degree. Their hyperspectral images (874⁻1734 nm) were collected using a hyperspectral reflectance imaging system. The spectra of the regions of interest were manually extracted from the HSI images. Then, principal components analysis was employed to compress the spectral data and select the optimal wavelengths based on loading weight analysis. Meanwhile, the random frog (RF) methodology and the successive projections algorithm were also adopted to pick effective wavelengths from the spectral data. Finally, least squares support vector machine (LS-SVM) was utilized to establish discriminative models using spectral reflectance and corresponding labeled classes for each degree of roast sample. The results showed that the LS-SVM model, established by the RF selecting method, with eight wavelengths performed very well, achieving an overall classification accuracy of 90.30%. In conclusion, HSI was illustrated as a potential technique for noninvasively classifying the roasting degrees of coffee beans and might have an important application for the development of nondestructive, real-time, and portable sensors to monitor the roasting process of coffee beans.

  8. Development of Noninvasive Classification Methods for Different Roasting Degrees of Coffee Beans Using Hyperspectral Imaging

    Directory of Open Access Journals (Sweden)

    Bingquan Chu

    2018-04-01

    Full Text Available This study aimed to develop an approach for quickly and noninvasively differentiating the roasting degrees of coffee beans using hyperspectral imaging (HSI. The qualitative properties of seven roasting degrees of coffee beans (unroasted, light, moderately light, light medium, medium, moderately dark, and dark were assayed, including moisture, crude fat, trigonelline, chlorogenic acid, and caffeine contents. These properties were influenced greatly by the respective roasting degree. Their hyperspectral images (874–1734 nm were collected using a hyperspectral reflectance imaging system. The spectra of the regions of interest were manually extracted from the HSI images. Then, principal components analysis was employed to compress the spectral data and select the optimal wavelengths based on loading weight analysis. Meanwhile, the random frog (RF methodology and the successive projections algorithm were also adopted to pick effective wavelengths from the spectral data. Finally, least squares support vector machine (LS-SVM was utilized to establish discriminative models using spectral reflectance and corresponding labeled classes for each degree of roast sample. The results showed that the LS-SVM model, established by the RF selecting method, with eight wavelengths performed very well, achieving an overall classification accuracy of 90.30%. In conclusion, HSI was illustrated as a potential technique for noninvasively classifying the roasting degrees of coffee beans and might have an important application for the development of nondestructive, real-time, and portable sensors to monitor the roasting process of coffee beans.

  9. A review of non-invasive imaging methods and applications in contaminant hydrogeology research.

    Science.gov (United States)

    Werth, Charles J; Zhang, Changyong; Brusseau, Mark L; Oostrom, Mart; Baumann, Thomas

    2010-04-01

    Contaminant hydrogeological processes occurring in porous media are typically not amenable to direct observation. As a result, indirect measurements (e.g., contaminant breakthrough at a fixed location) are often used to infer processes occurring at different scales, locations, or times. To overcome this limitation, non-invasive imaging methods are increasingly being used in contaminant hydrogeology research. Four of the most common methods, and the subjects of this review, are optical imaging using UV or visible light, dual-energy gamma radiation, X-ray microtomography, and magnetic resonance imaging (MRI). Non-invasive imaging techniques have provided valuable insights into a variety of complex systems and processes, including porous media characterization, multiphase fluid distribution, fluid flow, solute transport and mixing, colloidal transport and deposition, and reactions. In this paper we review the theory underlying these methods, applications of these methods to contaminant hydrogeology research, and methods' advantages and disadvantages. As expected, there is no perfect method or tool for non-invasive imaging. However, optical methods generally present the least expensive and easiest options for imaging fluid distribution, solute and fluid flow, colloid transport, and reactions in artificial two-dimensional (2D) porous media. Gamma radiation methods present the best opportunity for characterization of fluid distributions in 2D at the Darcy scale. X-ray methods present the highest resolution and flexibility for three-dimensional (3D) natural porous media characterization, and 3D characterization of fluid distributions in natural porous media. And MRI presents the best option for 3D characterization of fluid distribution, fluid flow, colloid transport, and reaction in artificial porous media. Obvious deficiencies ripe for method development are the ability to image transient processes such as fluid flow and colloid transport in natural porous media in three

  10. NUCLEAR IMAGING IN THE DIAGNOSIS OF CARDIAC AMYLOIDOSIS

    Directory of Open Access Journals (Sweden)

    V. B. Sergienko

    2018-01-01

    Full Text Available Histological analysis of endomyocardial tissue is still the gold standard for the diagnosis of cardiac amyloidosis but has its limitations. Accordingly, there is a need for noninvasive techniques to cardiac amyloidosis diagnostics. Echocardiography and magnetic resonance imaging can show characteristics which may not be very specific for cardiac amyloid. Recently, new opportunities of nuclear imaging in risk stratification and assessment of prognosis for patients with cardiac amyloidosis have appeared. During the last two decades different classes of radiopharmaceuticals have been developed based on compounds tropic to the components of amyloid infiltrates. In this paper we describe the current possibilities and perspectives of nuclear medicine techniques in patients with cardiac amyloidosis, including osteotropic and neurotropic scintigraphy, single-photon and positron emission tomography

  11. Non-invasive monitoring of Streptococcus pyogenes vaccine efficacy using biophotonic imaging.

    Directory of Open Access Journals (Sweden)

    Faraz M Alam

    Full Text Available Streptococcus pyogenes infection of the nasopharynx represents a key step in the pathogenic cycle of this organism and a major focus for vaccine development, requiring robust models to facilitate the screening of potentially protective antigens. One antigen that may be an important target for vaccination is the chemokine protease, SpyCEP, which is cell surface-associated and plays a role in pathogenesis. Biophotonic imaging (BPI can non-invasively characterize the spatial location and abundance of bioluminescent bacteria in vivo. We have developed a bioluminescent derivative of a pharyngeal S. pyogenes strain by transformation of an emm75 clinical isolate with the luxABCDE operon. Evaluation of isogenic recombinant strains in vitro and in vivo confirmed that bioluminescence conferred a growth deficit that manifests as a fitness cost during infection. Notwithstanding this, bioluminescence expression permitted non-invasive longitudinal quantitation of S. pyogenes within the murine nasopharynx albeit with a detection limit corresponding to approximately 10(5 bacterial colony forming units (CFU in this region. Vaccination of mice with heat killed streptococci, or with SpyCEP led to a specific IgG response in the serum. BPI demonstrated that both vaccine candidates reduced S. pyogenes bioluminescence emission over the course of nasopharyngeal infection. The work suggests the potential for BPI to be used in the non-invasive longitudinal evaluation of potential S. pyogenes vaccines.

  12. Insights into Parkinson's disease models and neurotoxicity using non-invasive imaging

    International Nuclear Information System (INIS)

    Sanchez-Pernaute, Rosario; Brownell, Anna-Liisa; Jenkins, Bruce G.; Isacson, Ole

    2005-01-01

    Loss of dopamine in the nigrostriatal system causes a severe impairment in motor function in patients with Parkinson's disease and in experimental neurotoxic models of the disease. We have used non-invasive imaging techniques such as positron emission tomography (PET) and functional magnetic resonance imaging (MRI) to investigate in vivo the changes in the dopamine system in neurotoxic models of Parkinson's disease. In addition to classic neurotransmitter studies, in these models, it is also possible to characterize associated and perhaps pathogenic factors, such as the contribution of microglia activation and inflammatory responses to neuronal damage. Functional imaging techniques are instrumental to our understanding and modeling of disease mechanisms, which should in turn lead to development of new therapies for Parkinson's disease and other neurodegenerative disorders

  13. Non-invasive detection of murals with pulsed terahertz reflected imaging system

    Science.gov (United States)

    Yuan, Minjie; Sun, Wenfeng; Wang, Xinke; Ye, Jiasheng; Wang, Sen; Zhang, Qunxi; Zhang, Yan

    2015-11-01

    Pulsed terahertz reflected imaging technology has been expected to have great potential for the non-invasive analysis of artworks. In this paper, three types of defects hidden in the plaster used to simulate the cases of defects in the murals, have been investigated by a pulsed terahertz reflected imaging system. These preset defects include a circular groove, a cross-shaped slit and a piece of "Y-type" metal plate built in the plaster. With the terahertz reflective tomography, information about defects has been determined involving the thickness from the surface of sample to the built-in defect, the profile and distribution of the defect. Additionally, three-dimensional analyses have been performed in order to reveal the internal structure of defects. Terahertz reflective imaging can be applied to the defect investigation of the murals.

  14. Fibered Confocal Fluorescence Microscopy for the Noninvasive Imaging of Langerhans Cells in Macaques.

    Science.gov (United States)

    Todorova, Biliana; Salabert, Nina; Tricot, Sabine; Boisgard, Raphaël; Rathaux, Mélanie; Le Grand, Roger; Chapon, Catherine

    2017-01-01

    We developed a new approach to visualize skin Langerhans cells by in vivo fluorescence imaging in nonhuman primates. Macaques were intradermally injected with a monoclonal, fluorescently labeled antibody against HLA-DR molecule and were imaged for up to 5 days by fibered confocal microscopy (FCFM). The network of skin Langerhans cells was visualized by in vivo fibered confocal fluorescence microscopy. Quantification of Langerhans cells revealed no changes to cell density with time. Ex vivo experiments confirmed that injected fluorescent HLA-DR antibody specifically targeted Langerhans cells in the epidermis. This study demonstrates the feasibility of single-cell, in vivo imaging as a noninvasive technique to track Langerhans cells in nontransgenic animals.

  15. Dynamic tissue phantoms and their use in assessment of a noninvasive optical plethysmography imaging device

    Science.gov (United States)

    Thatcher, Jeffrey E.; Plant, Kevin D.; King, Darlene R.; Block, Kenneth L.; Fan, Wensheng; DiMaio, J. Michael

    2014-05-01

    Non-contact photoplethysmography (PPG) has been studied as a method to provide low-cost and non-invasive medical imaging for a variety of near-surface pathologies and two dimensional blood oxygenation measurements. Dynamic tissue phantoms were developed to evaluate this technology in a laboratory setting. The purpose of these phantoms was to generate a tissue model with tunable parameters including: blood vessel volume change; pulse wave frequency; and optical scattering and absorption parameters. A non-contact PPG imaging system was evaluated on this model and compared against laser Doppler imaging (LDI) and a traditional pulse oximeter. Results indicate non-contact PPG accurately identifies pulse frequency and appears to identify signals from optically dense phantoms with significantly higher detection thresholds than LDI.

  16. Noninvasive Quantitative Imaging of Collagen Microstructure in Three-Dimensional Hydrogels Using High-Frequency Ultrasound.

    Science.gov (United States)

    Mercado, Karla P; Helguera, María; Hocking, Denise C; Dalecki, Diane

    2015-07-01

    Collagen I is widely used as a natural component of biomaterials for both tissue engineering and regenerative medicine applications. The physical and biological properties of fibrillar collagens are strongly tied to variations in collagen fiber microstructure. The goal of this study was to develop the use of high-frequency quantitative ultrasound to assess collagen microstructure within three-dimensional (3D) hydrogels noninvasively and nondestructively. The integrated backscatter coefficient (IBC) was employed as a quantitative ultrasound parameter to detect, image, and quantify spatial variations in collagen fiber density and diameter. Collagen fiber microstructure was varied by fabricating hydrogels with different collagen concentrations or polymerization temperatures. IBC values were computed from measurements of the backscattered radio-frequency ultrasound signals collected using a single-element transducer (38-MHz center frequency, 13-47 MHz bandwidth). The IBC increased linearly with increasing collagen concentration and decreasing polymerization temperature. Parametric 3D images of the IBC were generated to visualize and quantify regional variations in collagen microstructure throughout the volume of hydrogels fabricated in standard tissue culture plates. IBC parametric images of corresponding cell-embedded collagen gels showed cell accumulation within regions having elevated collagen IBC values. The capability of this ultrasound technique to noninvasively detect and quantify spatial differences in collagen microstructure offers a valuable tool to monitor the structural properties of collagen scaffolds during fabrication, to detect functional differences in collagen microstructure, and to guide fundamental research on the interactions of cells and collagen matrices.

  17. Targets and probes for non-invasive imaging of β-cells

    Energy Technology Data Exchange (ETDEWEB)

    Jodal, Andreas; Behe, Martin [Paul Scherrer Institut, Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Villigen (Switzerland); Schibli, Roger [Paul Scherrer Institut, Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Villigen (Switzerland); ETH Zurich, Department of Chemistry and Applied Biosciences, Zurich (Switzerland)

    2017-04-15

    β-cells, located in the islets of the pancreas, are responsible for production and secretion of insulin and play a crucial role in blood sugar regulation. Pathologic β-cells often cause serious medical conditions affecting blood glucose level, which severely impact life quality and are life-threatening if untreated. With 347 million patients, diabetes is one of the most prevalent diseases, and will continue to be one of the largest socioeconomic challenges in the future. The diagnosis still relies mainly on indirect methods like blood sugar measurements. A non-invasive diagnostic imaging modality would allow direct evaluation of β-cell mass and would be a huge step towards personalized medicine. Hyperinsulinism is another serious condition caused by β-cells that excessively secrete insulin, like for instance β-cell hyperplasia and insulinomas. Treatment options with drugs are normally not curative, whereas curative procedures usually consist of the resection of affected regions for which, however, an exact localization of the foci is necessary. In this review, we describe potential tracers under development for targeting β-cells with focus on radiotracers for PET and SPECT imaging, which allow the non-invasive visualization of β-cells. We discuss either the advantages or limitations for the various tracers and modalities. This article concludes with an outlook on future developments and discuss the potential of new imaging probes including dual probes that utilize functionalities for both a radioactive and optical moiety as well as for theranostic applications. (orig.)

  18. Targets and probes for non-invasive imaging of β-cells

    International Nuclear Information System (INIS)

    Jodal, Andreas; Behe, Martin; Schibli, Roger

    2017-01-01

    β-cells, located in the islets of the pancreas, are responsible for production and secretion of insulin and play a crucial role in blood sugar regulation. Pathologic β-cells often cause serious medical conditions affecting blood glucose level, which severely impact life quality and are life-threatening if untreated. With 347 million patients, diabetes is one of the most prevalent diseases, and will continue to be one of the largest socioeconomic challenges in the future. The diagnosis still relies mainly on indirect methods like blood sugar measurements. A non-invasive diagnostic imaging modality would allow direct evaluation of β-cell mass and would be a huge step towards personalized medicine. Hyperinsulinism is another serious condition caused by β-cells that excessively secrete insulin, like for instance β-cell hyperplasia and insulinomas. Treatment options with drugs are normally not curative, whereas curative procedures usually consist of the resection of affected regions for which, however, an exact localization of the foci is necessary. In this review, we describe potential tracers under development for targeting β-cells with focus on radiotracers for PET and SPECT imaging, which allow the non-invasive visualization of β-cells. We discuss either the advantages or limitations for the various tracers and modalities. This article concludes with an outlook on future developments and discuss the potential of new imaging probes including dual probes that utilize functionalities for both a radioactive and optical moiety as well as for theranostic applications. (orig.)

  19. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals.

    Directory of Open Access Journals (Sweden)

    Krisztina Manzano-Szalai

    Full Text Available In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i milk allergy, ii peanut allergy and iii egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour.

  20. Non-invasive imaging of retinal blood flow in myeloproliferative neoplasms

    DEFF Research Database (Denmark)

    Willerslev, Anne; Hansen, Mathias M; Klefter, Oliver Niels

    2017-01-01

    PURPOSE: To study the circulation in the retinal vessels in patients with blood dyscrasia due to myeloproliferative neoplasms using non-invasive retinal imaging. METHODS: Prospective consecutive case series of seven treatment-naïve patients with chronic myeloid leukaemia (n = 2), polycythemia vera...... present at baseline in patients with chronic myeloid leukaemia and were replaced by normal patterns at follow-up. Retinopathy, in the form of cotton-wool spots and retinal haemorrhages, was found at presentation in the two patients with chronic myeloid leukaemia and in one patient with polycythemia vera...

  1. Noninvasive ultrasonic measurements of temperature distribution and heat fluxes in nuclear systems

    International Nuclear Information System (INIS)

    Jia, Yunlu; Skliar, Mikhail

    2015-01-01

    Measurements of temperature and heat fluxes through structural materials are important in many nuclear systems. One such example is dry storage casks (DSC) that are built to store highly radioactive materials, such as spent nuclear reactor fuel. The temperature inside casks must be maintained within allowable limits of the fuel assemblies and the DSC components because many degradation mechanisms are thermally controlled. In order to obtain direct, real-time measurements of temperature distribution without insertion of sensing elements into harsh environment of storage casks, we are developing noninvasive ultrasound (US) methods for measuring spatial distribution of temperature inside solid materials, such as concrete overpacks, steel casings, thimbles, and rods. The measured temperature distribution can then be used to obtain heat fluxes that provide calorimetric characterisation of the fuel decay, fuel distribution inside the cask, its integrity, and accounting of nuclear materials. The physical basis of the proposed approach is the temperature dependence of the speed of sound in solids. By measuring the time it takes an ultrasound signal to travel a known distance between a transducer and a receiver, the indication about the temperature distribution along the path of the ultrasound propagation may be obtained. However, when temperature along the path of US propagation is non-uniform, the overall time of flight of an ultrasound signal depends on the temperature distribution in a complex and unknown way. To overcome this difficulty, the central idea of our method is to create an US propagation path inside material of interest which incorporates partial ultrasound reflectors (back scatterers) at known locations and use the train of created multiple echoes to estimate the temperature distribution. In this paper, we discuss experimental validation of this approach, the achievable accuracy and spatial resolution of the measured temperature profile, and stress the

  2. Non-invasive long-term fluorescence live imaging of Tribolium castaneum embryos.

    Science.gov (United States)

    Strobl, Frederic; Stelzer, Ernst H K

    2014-06-01

    Insect development has contributed significantly to our understanding of metazoan development. However, most information has been obtained by analyzing a single species, the fruit fly Drosophila melanogaster. Embryonic development of the red flour beetle Tribolium castaneum differs fundamentally from that of Drosophila in aspects such as short-germ development, embryonic leg development, extensive extra-embryonic membrane formation and non-involuted head development. Although Tribolium has become the second most important insect model organism, previous live imaging attempts have addressed only specific questions and no long-term live imaging data of Tribolium embryogenesis have been available. By combining light sheet-based fluorescence microscopy with a novel mounting method, we achieved complete, continuous and non-invasive fluorescence live imaging of Tribolium embryogenesis at high spatiotemporal resolution. The embryos survived the 2-day or longer imaging process, developed into adults and produced fertile progeny. Our data document all morphogenetic processes from the rearrangement of the uniform blastoderm to the onset of regular muscular movement in the same embryo and in four orientations, contributing significantly to the understanding of Tribolium development. Furthermore, we created a comprehensive chronological table of Tribolium embryogenesis, integrating most previous work and providing a reference for future studies. Based on our observations, we provide evidence that serosa window closure and serosa opening, although deferred by more than 1 day, are linked. All our long-term imaging datasets are available as a resource for the community. Tribolium is only the second insect species, after Drosophila, for which non-invasive long-term fluorescence live imaging has been achieved. © 2014. Published by The Company of Biologists Ltd.

  3. A General Approach to the Non-Invasive Imaging of Transgenes Using Cis-Linked Herpes Simplex Virus Thymidine Kinase

    Directory of Open Access Journals (Sweden)

    Juri G. Tjuvajev

    1999-10-01

    Full Text Available Non-invasive imaging of gene expression opens new prospects for the study of transgenic animals and the implementation of genetically based therapies in patients. We have sought to establish a general paradigm to enable whole body non-invasive imaging of any transgene. We show that the expression and imaging of HSV1-tk (a marker gene can be used to monitor the expression of the LacZ gene (a second gene under the transcriptional control of a single promoter within a bicistronic unit that includes a type II internal ribosomal entry site. In cells bearing a single copy of the vector, the expression of the two genes is proportional and constant, both in vitro and in vivo. We demonstrate that non-invasive imaging of HSV1-tk gene accurately reflects the topology and activity of the other cis-linked transgene.

  4. Chronic pelvic pain: how does noninvasive imaging compare with diagnostic laparoscopy?

    Science.gov (United States)

    Tirlapur, Seema A; Daniels, Jane P; Khan, Khalid S

    2015-12-01

    Chronic pelvic pain (CPP) has an annual prevalence of 38/1000 in the UK, with coexisting pathologies often present. Diagnostic laparoscopy has long been the gold standard diagnostic test, but with up to 40% showing no abnormality, we explore the value of noninvasive imaging, such as pelvic ultrasound and MRI. A literature review from inception until January 2015 of the following databases: PubMed, MEDLINE, Cumulative Index to Nursing and Allied Health Literature, Excerpta Medica database, and System for Information on Grey Literature in Europe were performed to identify published studies assessing the usefulness of ultrasound, MRI, and laparoscopy in the diagnosis of CPP. Three studies (194 women) addressed their comparative performance in patients with endometriosis, showing the sensitivity of ultrasound ranged between 58 and 88.5%; MRI was 56-91.5% and in the one study using histology as its reference standard, the sensitivity of laparoscopy was 85.7%. Noninvasive imaging has the additional benefit of being well tolerated, safer, and cheaper than surgery. CPP, by nature of its multifactorial causation, can be difficult to manage and often requires a multidisciplinary team. Ultrasound and MRI may provide information about the presence or lack of abnormality, which would allow general practitioners or office gynaecologists to initiate treatment and think about surgery as a second-line investigative tool.

  5. Non-invasive monitoring of in vivo hydrogel degradation and cartilage regeneration by multiparametric MR imaging

    Science.gov (United States)

    Chen, Zelong; Yan, Chenggong; Yan, Shina; Liu, Qin; Hou, Meirong; Xu, Yikai; Guo, Rui

    2018-01-01

    Numerous biodegradable hydrogels for cartilage regeneration have been widely used in the field of tissue engineering. However, to non-invasively monitor hydrogel degradation and efficiently evaluate cartilage restoration in situ is still challenging. Methods: A ultrasmall superparamagnetic iron oxide (USPIO)-labeled cellulose nanocrystal (CNC)/silk fibroin (SF)-blended hydrogel system was developed to monitor hydrogel degradation during cartilage regeneration. The physicochemical characterization and biocompatibility of the hydrogel were evaluated in vitro. The in vivo hydrogel degradation and cartilage regeneration of different implants were assessed using multiparametric magnetic resonance imaging (MRI) and further confirmed by histological analysis in a rabbit cartilage defect model for 3 months. Results: USPIO-labeled hydrogels showed sufficient MR contrast enhancement and retained stability without loss of the relaxation rate. Neither the mechanical properties of the hydrogels nor the proliferation of bone-marrow mesenchymal stem cells (BMSCs) were affected by USPIO labeling in vitro. CNC/SF hydrogels with BMSCs degraded more quickly than the acellular hydrogels as reflected by the MR relaxation rate trends in vivo. The morphology of neocartilage was noninvasively visualized by the three-dimensional water-selective cartilage MRI scan sequence, and the cartilage repair was further demonstrated by macroscopic and histological observations. Conclusion: This USPIO-labeled CNC/SF hydrogel system provides a new perspective on image-guided tissue engineering for cartilage regeneration. PMID:29464005

  6. Theranostic Iron Oxide/Gold Ion Nanoprobes for MR Imaging and Noninvasive RF Hyperthermia.

    Science.gov (United States)

    Fazal, Sajid; Paul-Prasanth, Bindhu; Nair, Shantikumar V; Menon, Deepthy

    2017-08-30

    This work focuses on the development of a nanoparticulate system that can be used for magnetic resonance (MR) imaging and E-field noninvasive radiofrequency (RF) hyperthermia. For this purpose, an amine-functional gold ion complex (GIC), [Au(III)(diethylenetriamine)Cl]Cl 2 , which generates heat upon RF exposure, was conjugated to carboxyl-functional poly(acrylic acid)-capped iron-oxide nanoparticles (IO-PAA NPs) to form IO-GIC NPs of size ∼100 nm. The multimodal superparamagnetic IO-GIC NPs produced T2-contrast on MR imaging and unlike IO-PAA NPs generated heat on RF exposure. The RF heating response of IO-GIC NPs was found to be dependent on the RF power, exposure period, and particle concentration. IO-GIC NPs at a concentration of 2.5 mg/mL showed a high heating response (δT) of ∼40 °C when exposed to 100 W RF power for 1 min. In vitro cytotoxicity measurements on NIH-3T3 fibroblast cells and 4T1 cancer cells showed that IO-GIC NPs are cytocompatible at high NP concentrations for up to 72 h. Upon in vitro RF exposure (100 W, 1 min), a high thermal response leads to cell death of 4T1 cancer cells incubated with IO-GIC NPs (1 mg/mL). Hematoxylin and eosin imaging of rat liver tissues injected with 100 μL of 2.5 mg/mL IO-GIC NPs and exposed to low RF power of 20 W for 10 min showed significant loss of tissue morphology at the site of injection, as against RF-exposed or nanoparticle-injected controls. In vivo MR imaging and noninvasive RF exposure of 4T1-tumor-bearing mice after IO-GIC NP administration showed T2 contrast enhancement and a localized generation of high temperatures in tumors, leading to tumor tissue damage. Furthermore, the administration of IO-GIC NPs followed by RF exposure showed no adverse acute toxicity effects in vivo. Thus, IO-GIC NPs show good promise as a theranostic agent for magnetic resonance imaging and noninvasive RF hyperthermia for cancer.

  7. Non-invasive imaging technics for diagnosis in children with surgical abdominal diseases

    International Nuclear Information System (INIS)

    Nakada, Koonosuke; Sato, Yutaka; Shimoyamada, Hiroaki; Kim, Yoshitaka; Ishikawa, Misao

    1984-01-01

    The usefullness of non-invasive imaging technics namely CT and ultrasonography was evaluated in pediatric surgical abdominal diseases, under the categoly of A) inflammatory masses (10), B) biliary abnormalities (6), C) neoplasms (12), and D) blunt abdominal traumas (8), which were experienced at St. Marianna University Hospital from April 1978 to January 1982. According to the results of the clinical study, the plan of useful diagnostic approaches in each group by means of several imaging technics was outlined. In group A and B, ultrasonography is usually suffice for diagnosis and therapy planning, whereas in group C and D, in addition to the ultrasound, CT is sometimes required for evaluating the involvement of vascular structures and sorrounding vital structures in cases of neoplasm, and coexisting injuries in the traumas. (author)

  8. Quantitative non-invasive intracellular imaging of Plasmodium falciparum infected human erythrocytes

    International Nuclear Information System (INIS)

    Edward, Kert; Farahi, Faramarz

    2014-01-01

    Malaria is a virulent pathological condition which results in over a million annual deaths. The parasitic agent Plasmodium falciparum has been extensively studied in connection with this epidemic but much remains unknown about its development inside the red blood cell host. Optical and fluorescence imaging are among the two most common procedures for investigating infected erythrocytes but both require the introduction of exogenous contrast agents. In this letter, we present a procedure for the non-invasive in situ imaging of malaria infected red blood cells. The procedure is based on the utilization of simultaneously acquired quantitative phase and independent topography data to extract intracellular information. Our method allows for the identification of the developmental stages of the parasite and facilitates in situ analysis of the morphological changes associated with the progression of this disease. This information may assist in the development of efficacious treatment therapies for this condition. (letters)

  9. Optimal Non-Invasive Fault Classification Model for Packaged Ceramic Tile Quality Monitoring Using MMW Imaging

    Science.gov (United States)

    Agarwal, Smriti; Singh, Dharmendra

    2016-04-01

    Millimeter wave (MMW) frequency has emerged as an efficient tool for different stand-off imaging applications. In this paper, we have dealt with a novel MMW imaging application, i.e., non-invasive packaged goods quality estimation for industrial quality monitoring applications. An active MMW imaging radar operating at 60 GHz has been ingeniously designed for concealed fault estimation. Ceramic tiles covered with commonly used packaging cardboard were used as concealed targets for undercover fault classification. A comparison of computer vision-based state-of-the-art feature extraction techniques, viz, discrete Fourier transform (DFT), wavelet transform (WT), principal component analysis (PCA), gray level co-occurrence texture (GLCM), and histogram of oriented gradient (HOG) has been done with respect to their efficient and differentiable feature vector generation capability for undercover target fault classification. An extensive number of experiments were performed with different ceramic tile fault configurations, viz., vertical crack, horizontal crack, random crack, diagonal crack along with the non-faulty tiles. Further, an independent algorithm validation was done demonstrating classification accuracy: 80, 86.67, 73.33, and 93.33 % for DFT, WT, PCA, GLCM, and HOG feature-based artificial neural network (ANN) classifier models, respectively. Classification results show good capability for HOG feature extraction technique towards non-destructive quality inspection with appreciably low false alarm as compared to other techniques. Thereby, a robust and optimal image feature-based neural network classification model has been proposed for non-invasive, automatic fault monitoring for a financially and commercially competent industrial growth.

  10. Noninvasive ultrasound molecular imaging of the effect of statins on endothelial inflammatory phenotype in early atherosclerosis.

    Directory of Open Access Journals (Sweden)

    Elham Khanicheh

    Full Text Available BACKGROUND/OBJECTIVES: Inflammatory changes on the endothelium are responsible for leukocyte recruitment to plaques in atherosclerosis. Noninvasive assessment of treatment-effects on endothelial inflammation may be of use for managing medical therapy and developing novel therapies. We hypothesized that molecular imaging of vascular cell adhesion molecule-1 (VCAM-1 with contrast enhanced ultrasound (CEU could assess treatment effects on endothelial phenotype in early atherosclerosis. METHODS: Mice with atherosclerosis produced by gene deletion of the LDL-receptor and Apobec-1-editing protein were studied. At 12 weeks of age, mice received 8 weeks of regular chow or atorvastatin-enriched chow (10 mg/kg/day. At 20 weeks, CEU molecular imaging for aortic endothelial VCAM-1 expression was performed with VCAM-1-targeted (MB(VCAM and control microbubbles (MB(Ctr. Aortic wall thickness was assessed with high frequency ultrasound. Histology, immunohistology and Western blot were used to assess plaque burden and VCAM-1 expression. RESULTS: Plaque burden was reduced on histology, and VCAM-1 was reduced on Western blot by atorvastatin, which corresponded to less endothelial expression of VCAM-1 on immunohistology. High frequency ultrasound did not detect differences in aortic wall thickness between groups. In contrast, CEU molecular imaging demonstrated selective signal enhancement for MB(VCAM in non-treated animals (MB(VCAM 2±0.3 vs MB(Ctr 0.7±0.2, p<0.01, but not in statin-treated animals (MB(VCAM 0.8±0.2 vs MB(Ctr 1.0±0.2, p = ns; p<0.01 for the effect of statin on MB(VCAM signal. CONCLUSIONS: Non-invasive CEU molecular imaging detects the effects of anti-inflammatory treatment on endothelial inflammation in early atherosclerosis. This easily accessible, low-cost technique may be useful in assessing treatment effects in preclinical research and in patients.

  11. Medical Imaging Informatics in Nuclear Medicine

    NARCIS (Netherlands)

    van Ooijen, Peter; Glaudemans, Andor W.J.M.; Medema, Jitze; van Zanten, Annie K.; Dierckx, Rudi A.J.O.; Ahaus, C.T.B. (Kees)

    2016-01-01

    Medical imaging informatics is gaining importance in medicine both in clinical practice and in scientific research. Besides radiology, nuclear medicine is also a major stakeholder in medical imaging informatics because of the variety of available imaging modalities and the imaging-oriented operation

  12. Nuclear magnetic resonance imaging method

    International Nuclear Information System (INIS)

    Johnson, G.; MacDonald, J.; Hutchison, S.; Eastwood, L.M.; Redpath, T.W.T.; Mallard, J.R.

    1984-01-01

    A method of deriving three dimensional image information from an object using nuclear magnetic resonance signals comprises subjecting the object to a continuous, static magnetic field and carrying out the following set of sequential steps: 1) exciting nuclear spins in a selected volume (90deg pulse); 2) applying non-aligned first, second and third gradients of the magnetic field; 3) causing the spins to rephase periodically by reversal of the first gradient to produce spin echoes, and applying pulses of the second gradient prior to every read-out of an echo signal from the object, to differently encode the spin in the second gradient direction for each read-out signal. The above steps 1-3 are then successively repeated with different values of gradient of the third gradient, there being a recovery interval between the repetition of successive sets of steps. Alternate echoes only are read out, the other echoes being time-reversed and ignored for convenience. The resulting signals are appropriately sampled, set out in an array and subjected to three dimensional Fourier transformation. (author)

  13. Using Non-Invasive Multi-Spectral Imaging to Quantitatively Assess Tissue Vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, A; Chernomordik, V; Riley, J; Hassan, M; Amyot, F; Dasgeb, B; Demos, S G; Pursley, R; Little, R; Yarchoan, R; Tao, Y; Gandjbakhche, A H

    2007-10-04

    This research describes a non-invasive, non-contact method used to quantitatively analyze the functional characteristics of tissue. Multi-spectral images collected at several near-infrared wavelengths are input into a mathematical optical skin model that considers the contributions from different analytes in the epidermis and dermis skin layers. Through a reconstruction algorithm, we can quantify the percent of blood in a given area of tissue and the fraction of that blood that is oxygenated. Imaging normal tissue confirms previously reported values for the percent of blood in tissue and the percent of blood that is oxygenated in tissue and surrounding vasculature, for the normal state and when ischemia is induced. This methodology has been applied to assess vascular Kaposi's sarcoma lesions and the surrounding tissue before and during experimental therapies. The multi-spectral imaging technique has been combined with laser Doppler imaging to gain additional information. Results indicate that these techniques are able to provide quantitative and functional information about tissue changes during experimental drug therapy and investigate progression of disease before changes are visibly apparent, suggesting a potential for them to be used as complementary imaging techniques to clinical assessment.

  14. Recent developments in the food quality detected by non-invasive nuclear magnetic resonance technology.

    Science.gov (United States)

    Fan, Kai; Zhang, Min

    2018-02-16

    Nuclear magnetic resonance (NMR) is a rapid, accurate and non-invasive technology and widely used to detect the quality of food, particularly to fruits and vegetables, meat and aquatic products. This review is a survey of recent developments in experimental results for the quality of food on various NMR technologies in processing and storage over the past decade. Following a discussion of the quality discrimination and classification of food, analysis of food compositions and detection of physical, chemical, structural and microbiological properties of food are outlined. Owing to high cost, low detection limit and sensitivity, the professional knowledge involved and the safety issues related to the maintenance of the magnetic field, so far the practical applications are limited to detect small range of food. In order to promote applications for a broader range of foods further research and development efforts are needed to overcome the limitations of NMR in the detection process. The needs and opportunities for future research and developments are outlined.

  15. Nuclear imaging in reflux diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Bares, R.

    1988-12-01

    Duodenogastric and gastroesophageal refluxes can be accurately detected by hepatobiliary and gastroesophageal scintigraphy. These procedures are non-invasive and easy to perform. Practical details and evaluation are described. Subsequent to a review of diagnostic results, indications are discussed. Both techniques should be applied in cases where morphological examinations did not yield any pathologic result and clinical symptoms are suggestive for functional disturbances.

  16. Diagnosis of cirrhosis and portal hypertension: imaging, non-invasive markers of fibrosis and liver biopsy

    Science.gov (United States)

    Procopet, Bogdan

    2017-01-01

    Abstract The concept of ‘cirrhosis’ is evolving and it is now clear that compensated and decompensated cirrhosis are completely different in terms of prognosis. Furthermore, the term ‘advanced chronic liver disease (ACLD)’ better reflects the continuum of histological changes occurring in the liver, which continue to progress even after cirrhosis has developed, and might regress after removing the etiological factor causing the liver disease. In compensated ACLD, portal hypertension marks the progression to a stage with higher risk of clinical complication and requires an appropriate evaluation and treatment. Invasive tests to diagnose cirrhosis (liver biopsy) and portal hypertension (hepatic venous pressure gradient measurement and endoscopy) remain of crucial importance in several difficult clinical scenarios, but their need can be reduced by using different non-invasive tests in standard cases. Among non-invasive tests, the accepted use, major limitations and major benefits of serum markers of fibrosis, elastography and imaging methods are summarized in the present review. PMID:28533906

  17. Noninvasive assessment of coronary collaterals in man by PET perfusion imaging

    International Nuclear Information System (INIS)

    Demer, L.L.; Gould, K.L.; Goldstein, R.A.; Kirkeeide, R.L.

    1990-01-01

    At present, coronary collateralization cannot be identified or assessed noninvasively in patients. In animal studies, coronary collaterals are associated with coronary steal, defined as a regional fall in perfusion during coronary arteriolar vasodilation. To determine the effect of coronary arteriolar vasodilation on collateral bed perfusion in man, myocardial perfusion imaging was performed before and after pharmacologic coronary vasodilation in patients with coronary artery disease (CAD). Regional myocardial activity of 82 Rb or 13 N ammonia was measured by positron emission tomography (PET) at rest and with intravenous dipyridamole/handgrip stress in 28 patients with angiographic collaterals and in 25 control patients with similar CAD severity by quantitative arteriography. Regional myocardial activity decreased after dipyridamole, indicating coronary steal, in 25 of 28 patients with angiographic collaterals and in only 4 of 25 control patients without angiographic collaterals. These findings suggest that developed collaterals are associated with myocardial steal in patients with CAD, allowing potential use of PET for non-invasive identification of coronary collateralization

  18. Noninvasive Vascular Displacement Estimation for Relative Elastic Modulus Reconstruction in Transversal Imaging Planes

    Directory of Open Access Journals (Sweden)

    Chris L. de Korte

    2013-03-01

    Full Text Available Atherosclerotic plaque rupture can initiate stroke or myocardial infarction. Lipid-rich plaques with thin fibrous caps have a higher risk to rupture than fibrotic plaques. Elastic moduli differ for lipid-rich and fibrous tissue and can be reconstructed using tissue displacements estimated from intravascular ultrasound radiofrequency (RF data acquisitions. This study investigated if modulus reconstruction is possible for noninvasive RF acquisitions of vessels in transverse imaging planes using an iterative 2D cross-correlation based displacement estimation algorithm. Furthermore, since it is known that displacements can be improved by compounding of displacements estimated at various beam steering angles, we compared the performance of the modulus reconstruction with and without compounding. For the comparison, simulated and experimental RF data were generated of various vessel-mimicking phantoms. Reconstruction errors were less than 10%, which seems adequate for distinguishing lipid-rich from fibrous tissue. Compounding outperformed single-angle reconstruction: the interquartile range of the reconstructed moduli for the various homogeneous phantom layers was approximately two times smaller. Additionally, the estimated lateral displacements were a factor of 2–3 better matched to the displacements corresponding to the reconstructed modulus distribution. Thus, noninvasive elastic modulus reconstruction is possible for transverse vessel cross sections using this cross-correlation method and is more accurate with compounding.

  19. Novel Noninvasive Brain Disease Detection System Using a Facial Image Sensor

    Directory of Open Access Journals (Sweden)

    Ting Shu

    2017-12-01

    Full Text Available Brain disease including any conditions or disabilities that affect the brain is fast becoming a leading cause of death. The traditional diagnostic methods of brain disease are time-consuming, inconvenient and non-patient friendly. As more and more individuals undergo examinations to determine if they suffer from any form of brain disease, developing noninvasive, efficient, and patient friendly detection systems will be beneficial. Therefore, in this paper, we propose a novel noninvasive brain disease detection system based on the analysis of facial colors. The system consists of four components. A facial image is first captured through a specialized sensor, where four facial key blocks are next located automatically from the various facial regions. Color features are extracted from each block to form a feature vector for classification via the Probabilistic Collaborative based Classifier. To thoroughly test the system and its performance, seven facial key block combinations were experimented. The best result was achieved using the second facial key block, where it showed that the Probabilistic Collaborative based Classifier is the most suitable. The overall performance of the proposed system achieves an accuracy −95%, a sensitivity −94.33%, a specificity −95.67%, and an average processing time (for one sample of <1 min at brain disease detection.

  20. General perspectives for molecular nuclear imaging

    International Nuclear Information System (INIS)

    Chung, June Key

    2004-01-01

    Molecular imaging provides a visualization of normal as well as abnormal cellular processes at a molecular or genetic level rather than at an anatomical level. Conventional medical imaging methods utilize the imaging signals produced by nonspecific physico-chemical interaction. However, molecular imaging methods utilize the imaging signals derived from specific cellular or molecular events. Because molecular and genetic changes precede anatomical change in the course of disease development, molecular imaging can detect early events in disease progression. In the near future, through molecular imaging we can understand basic mechanisms of disease, and diagnose earlier and, subsequently, treat earlier intractable disease such as cancer, neuro-degenerative diseases, and immunologic disorders. In beginning period, nuclear medicine started as a molecular imaging, and has had a leading role in the field of molecular imaging. But recently molecular imaging has been rapidly developed. Besides nuclear imaging, molecular imaging methods such as optical imaging, magnetic resonance imaging are emerging. Each imaging modalities have their advantages and weaknesses. The opportunities from molecular imaging look bright. We should try nuclear medicine continues to have a leading role in molecular imaging

  1. Development of an X-ray Computed Tomography System for Non-Invasive Imaging of Industrial Materials

    International Nuclear Information System (INIS)

    Abdullah, J.; Sipaun, S. M.; Mustapha, I.; Zain, R. M.; Rahman, M. F. A.; Mustapha, M.; Shaari, M. R.; Hassan, H.; Said, M. K. M.; Mohamad, G. H. P.; Ibrahim, M. M.

    2008-01-01

    X-ray computed tomography is a powerful non-invasive imaging technique for viewing an object's inner structures in two-dimensional cross-section images without the need to physically section it. The invention of CT techniques revolutionised the field of medical diagnostic imaging because it provided more detailed and useful information than any previous non-invasive imaging techniques. The method is increasingly being used in industry, aerospace, geosciences and archaeology. This paper describes the development of an X-ray computed tomography system for imaging of industrial materials. The theoretical aspects of CT scanner, the system configurations and the adopted algorithm for image reconstruction are discussed. The penetrating rays from a 160 kV industrial X-ray machine were used to investigate structures that manifest in a manufactured component or product. Some results were presented in this paper

  2. Myocardial imaging in the noninvasive evaluation of patients with suspected ischemic heart disease

    International Nuclear Information System (INIS)

    Pitt, B.; Strauss, H.W.

    1976-01-01

    Three noninvasive radioactive tracer techniques for evaluating patients with ischemic heart disease are described: (1) myocardial perfusion imaging, (2) acute infarct imaging, and (3) the gated blood pool scan. Myocardial perfusion imaging with tracers that distribute in the myocardium in relation to regional blood flow allows detection of patients with transmural and nontransmural infarction by the finding of decreased tracer concentration in the affected region of the myocardium. If these tracers are injected at the time of maximal stress to patients with significant coronary arterial stenosis but without infarction, areas of transient ischemia can be identified as zones of decreased tracer concentration not found when an examination is performed at rest. Acute infarct imaging with tracers that localize in acutely damaged tissue permits separation of patients with acute myocardial necrosis from those without infarction and those with more chronic damage. The gated blood pool scan permits assessment of left ventricular function and regional wall motion. The measurement of ventricular volumes, ejection fraction and regional wall motion adds significantly to the determination of hemodynamic variables in assessing patients with acute infarction. The technique also permits detection of right ventricular dysfunction. Performance of a combination of these radioactive tracer techniques is often advantageous, particularly in patients with suspected infarction. The techniques can establish whether infarction is present, whether it is acute, where the damage is located and how extensive it is; they can also provide a measure of the effect of this damage on left ventricular function

  3. Non-invasive assessment of vessel morphology and function in tumors by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kiessling, Fabian; Jugold, Manfred; Woenne, Eva C.; Brix, Gunnar

    2007-01-01

    The switch to an angiogenic phenotype is an important precondition for tumor growth, invasion and spread. Since newly formed vessels are characterized by structural, functional and molecular abnormalities, they offer promising targets for tumor diagnosis and therapy. Previous studies indicate that MRI is valuable to assess vessel morphology and function. It can be used to distinguish between benign and malignant lesions and to improve delineation of proliferating areas within heterogeneous tumors. In addition, tracer kinetic analysis of contrast-enhanced image series allows the estimation of well-defined physiological parameters such as blood volume, blood flow and vessel permeability. Frequently, changes of these parameters during cytostatic, anti-angiogenic and radiation therapy precede tumor volume reduction. Moreover, target-specific MRI techniques can be used to elucidate the expression of angiogenic markers at the molecular level. This review summarizes strategies for non-invasive characterization of tumor vascularization by functional and molecular MRI, hereby introducing representative preclinical and clinical applications. (orig.)

  4. Noninvasive imaging of transplanted living functional cells transfected with a reporter estrogen receptor gene

    Energy Technology Data Exchange (ETDEWEB)

    Takamatsu, Shinji [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan)]. E-mail: shinjit@fmsrsa.fukui-med.ac.jp; Furukawa, Takako [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan); Mori, Tetsuya [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan); Yonekura, Yoshiharu [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan); Fujibayashi, Yasuhisa [Biomedical Imaging Research Center, University of Fukui, 23-3 Shimoaizuki, Matsuoka, Yoshida, Fukui 910-1193 (Japan)

    2005-11-01

    The transplantation of functional cells such as dopaminergic cells into damaged tissue is now clinically ongoing, but at present the population of surviving cells at the transplantation site mostly cannot be noninvasively examined. To visualize surviving transplanted functional cells using a noninvasive method, we chose the estrogen receptor ligand binding domain (ERL) as a reporter molecule and 16{alpha}-[{sup 18}F]-fluoro-17{beta}-estradiol (FES) for its ligand. We used a mouse embryonic stem (ES) cell line for recipient cells as a model. To obtain ES cells that constitutively or inducibly express ERL, we transfected two types of expression vectors into EB5 parental ES cell line using the lipofection method and obtained about 30 clones for each of the two types of transfectants. Then, to examine the expression level of ERL, we performed Western blotting analysis. Ligand uptake experiments were carried out using [{sup 3}H]-estradiol with or without excessive unlabeled estradiol for control cells and ERL transfectants. Each selected clone was also used for in vivo positron emission tomography (PET) imaging studies involving FES in nude mice transplanted with control cells and ERL transfectants. In some of the clones transfected with the inducible-type ERL gene, protein was expressed much higher than in the controls. However, constitutive-type ERL gene-transfected ES cells showed no protein production in spite of their gene expression activity being considerably high. All clones also expressed equal levels of the Oct-3/4 gene, a marker of pluripotency, in comparison with the parental cells. Also, the specific uptake of [{sup 3}H]-estradiol was over 30 times higher in inducer-treated ERL-expressing ES cells compared to untreated control cells. Finally, by performing dynamic PET imaging, we successfully visualized ERL-expressing teratomas using FES.

  5. Noninvasive imaging of transplanted living functional cells transfected with a reporter estrogen receptor gene

    International Nuclear Information System (INIS)

    Takamatsu, Shinji; Furukawa, Takako; Mori, Tetsuya; Yonekura, Yoshiharu; Fujibayashi, Yasuhisa

    2005-01-01

    The transplantation of functional cells such as dopaminergic cells into damaged tissue is now clinically ongoing, but at present the population of surviving cells at the transplantation site mostly cannot be noninvasively examined. To visualize surviving transplanted functional cells using a noninvasive method, we chose the estrogen receptor ligand binding domain (ERL) as a reporter molecule and 16α-[ 18 F]-fluoro-17β-estradiol (FES) for its ligand. We used a mouse embryonic stem (ES) cell line for recipient cells as a model. To obtain ES cells that constitutively or inducibly express ERL, we transfected two types of expression vectors into EB5 parental ES cell line using the lipofection method and obtained about 30 clones for each of the two types of transfectants. Then, to examine the expression level of ERL, we performed Western blotting analysis. Ligand uptake experiments were carried out using [ 3 H]-estradiol with or without excessive unlabeled estradiol for control cells and ERL transfectants. Each selected clone was also used for in vivo positron emission tomography (PET) imaging studies involving FES in nude mice transplanted with control cells and ERL transfectants. In some of the clones transfected with the inducible-type ERL gene, protein was expressed much higher than in the controls. However, constitutive-type ERL gene-transfected ES cells showed no protein production in spite of their gene expression activity being considerably high. All clones also expressed equal levels of the Oct-3/4 gene, a marker of pluripotency, in comparison with the parental cells. Also, the specific uptake of [ 3 H]-estradiol was over 30 times higher in inducer-treated ERL-expressing ES cells compared to untreated control cells. Finally, by performing dynamic PET imaging, we successfully visualized ERL-expressing teratomas using FES

  6. Non-invasive quality evaluation of confluent cells by image-based orientation heterogeneity analysis.

    Science.gov (United States)

    Sasaki, Kei; Sasaki, Hiroto; Takahashi, Atsuki; Kang, Siu; Yuasa, Tetsuya; Kato, Ryuji

    2016-02-01

    In recent years, cell and tissue therapy in regenerative medicine have advanced rapidly towards commercialization. However, conventional invasive cell quality assessment is incompatible with direct evaluation of the cells produced for such therapies, especially in the case of regenerative medicine products. Our group has demonstrated the potential of quantitative assessment of cell quality, using information obtained from cell images, for non-invasive real-time evaluation of regenerative medicine products. However, image of cells in the confluent state are often difficult to evaluate, because accurate recognition of cells is technically difficult and the morphological features of confluent cells are non-characteristic. To overcome these challenges, we developed a new image-processing algorithm, heterogeneity of orientation (H-Orient) processing, to describe the heterogeneous density of cells in the confluent state. In this algorithm, we introduced a Hessian calculation that converts pixel intensity data to orientation data and a statistical profiling calculation that evaluates the heterogeneity of orientations within an image, generating novel parameters that yield a quantitative profile of an image. Using such parameters, we tested the algorithm's performance in discriminating different qualities of cellular images with three types of clinically important cell quality check (QC) models: remaining lifespan check (QC1), manipulation error check (QC2), and differentiation potential check (QC3). Our results show that our orientation analysis algorithm could predict with high accuracy the outcomes of all types of cellular quality checks (>84% average accuracy with cross-validation). Copyright © 2015 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  7. Image processing technology for nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Yong Beom; Kim, Woong Ki; Park, Soon Young

    1993-05-01

    Digital image processing technique is being actively studied since microprocessors and semiconductor memory devices have been developed in 1960's. Now image processing board for personal computer as well as image processing system for workstation is developed and widely applied to medical science, military, remote inspection, and nuclear industry. Image processing technology which provides computer system with vision ability not only recognizes nonobvious information but processes large information and therefore this technique is applied to various fields like remote measurement, object recognition and decision in adverse environment, and analysis of X-ray penetration image in nuclear facilities. In this report, various applications of image processing to nuclear facilities are examined, and image processing techniques are also analysed with the view of proposing the ideas for future applications. (Author)

  8. Nuclear magnetic resonance imaging in orthopedics

    International Nuclear Information System (INIS)

    Peters, P.E.; Matthiass, H.H.; Reiser, M.

    1990-01-01

    NMR imaging (MR tomography) allows the non-invasive diagnostic evaluation of cartilage, ligaments, tendons and muscles of the limbs, joints and the vertebral spine. The images are characterized by a good spatial resolution, and in contrast to the X-ray CT, sectional images can be done in all planes, as well as three-dimensional image reconstructions. The book reviews the current state of the art and foreseeable developments of NMR imaging of the supporting and connective tissue, also discussing the application of paramagnetic contrast media, and the novel NMR spectroscopy as a method pointing into the future. All contributions discussing the clinical aspects have been written jointly by experts in orthopedics and radiology. (orig.) With 153 figs., 8 tabs [de

  9. In vivo, noninvasive functional measurements of bone sarcoma using diffuse optical spectroscopic imaging

    Science.gov (United States)

    Peterson, Hannah M.; Hoang, Bang H.; Geller, David; Yang, Rui; Gorlick, Richard; Berger, Jeremy; Tingling, Janet; Roth, Michael; Gill, Jonathon; Roblyer, Darren

    2017-12-01

    Diffuse optical spectroscopic imaging (DOSI) is an emerging near-infrared imaging technique that noninvasively measures quantitative functional information in thick tissue. This study aimed to assess the feasibility of using DOSI to measure optical contrast from bone sarcomas. These tumors are rare and pose technical and practical challenges for DOSI measurements due to the varied anatomic locations and tissue depths of presentation. Six subjects were enrolled in the study. One subject was unable to be measured due to tissue contact sensitivity. For the five remaining subjects, the signal-to-noise ratio, imaging depth, optical properties, and quantitative tissue concentrations of oxyhemoglobin, deoxyhemoglobin, water, and lipids from tumor and contralateral normal tissues were assessed. Statistical differences between tumor and contralateral normal tissue were found in chromophore concentrations and optical properties for four subjects. Low signal-to-noise was encountered during several subject's measurements, suggesting increased detector sensitivity will help to optimize DOSI for this patient population going forward. This study demonstrates that DOSI is capable of measuring optical properties and obtaining functional information in bone sarcomas. In the future, DOSI may provide a means to stratify treatment groups and monitor chemotherapy response for this disease.

  10. Selective isolation and noninvasive analysis of circulating cancer stem cells through Raman imaging.

    Science.gov (United States)

    Cho, Hyeon-Yeol; Hossain, Md Khaled; Lee, Jin-Ho; Han, Jiyou; Lee, Hun Joo; Kim, Kyeong-Jun; Kim, Jong-Hoon; Lee, Ki-Bum; Choi, Jeong-Woo

    2018-04-15

    Circulating cancer stem cells (CCSCs), a rare circulating tumor cell (CTC) type, recently arose as a useful resource for monitoring and characterizing both cancers and their metastatic derivatives. However, due to the scarcity of CCSCs among hematologic cells in the blood and the complexity of the phenotype confirmation process, CCSC research can be extremely challenging. Hence, we report a nanoparticle-mediated Raman imaging method for CCSC characterization which profiles CCSCs based on their surface marker expression phenotypes. We have developed an integrated combinatorial Raman-Active Nanoprobe (RAN) system combined with a microfluidic chip to successfully process complete blood samples. CCSCs and CTCs were detected (90% efficiency) and classified in accordance with their respective surface marker expression via completely distinct Raman signals of RANs. Selectively isolated CCSCs (93% accuracy) were employed for both in vitro and in vivo tumor phenotyping to identify the tumorigenicity of the CCSCs. We utilized our new method to predict metastasis by screening blood samples from xenograft models, showing that upon CCSC detection, all subjects exhibited liver metastasis. Having highly efficient detection and noninvasive isolation capabilities, we have demonstrated that our RAN-based Raman imaging method will be valuable for predicting cancer metastasis and relapse via CCSC detection. Moreover, the exclusion of peak overlapping in CCSC analysis with our Raman imaging method will allow to expand the RAN families for various cancer types, therefore, increasing therapeutic efficacy by providing detailed molecular features of tumor subtypes. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Magnetic resonance imaging goes postmortem: noninvasive detection and assessment of myocardial infarction by postmortem MRI

    International Nuclear Information System (INIS)

    Jackowski, Christian; Warntjes, Marcel J.B.; Persson, Anders; Berge, Johan; Baer, Walter

    2011-01-01

    To investigate the performance of postmortem magnetic resonance imaging (pmMRI) in identification and characterization of lethal myocardial infarction in a non-invasive manner on human corpses. Before forensic autopsy, 20 human forensic corpses were examined on a 1.5-T system for the presence of myocardial infarction. Short axis, transversal and longitudinal long axis images (T1-weighted; T2-weighted; PD-weighted) were acquired in situ. In subsequent autopsy, the section technique was adapted to short axis images. Histological investigations were conducted to confirm autopsy and/or radiological diagnoses. Nineteen myocardial lesions were detected and age staged with pmMRI, of which 13 were histologically confirmed (chronic, subacute and acute). Six lesions interpreted as peracute by pmMRI showed no macroscopic or histological finding. Five of the six peracute lesions correlated well to coronary pathology, and one case displayed a severe hypertrophic alteration. pmMRI reliably demonstrates chronic, subacute and acute myocardial infarction in situ. In peracute cases pmMRI may display ischemic lesions undetectable at autopsy and routine histology. pmMRI has the potential to substantiate autopsy and to counteract the loss of reliable information on causes of death due to the recent disappearance of the clinical autopsy. (orig.)

  12. Noninvasive imaging of coronary arteries: current and future role of multidetector row computer tomography

    International Nuclear Information System (INIS)

    Nedevska, M.; Stoinova, V.

    2006-01-01

    Full text: This review will present the current and future role of cardiac computer tomography (CCT), and particular multidetector CCT, for imaging of atherosclerotic pathologic changes of the coronary arteries. Atherosclerosis and its cardio-vascular complications represent one of the major issues of public health in industrial countries. Different imaging modalities, including invasive coronarography, have been aimed to the diagnosis of the disease, when it provokes symptomatic decrease of the blood flow. In spite of development of surgical and percutaneous methods for coronary revascularization, coronary artery disease remains the major cause of death in North America and Europe. This demonstrates the need of novel, complementary diagnostic strategies, aimed to identify asymptomatic stages as the basis of pharmacological interventions. Noninvasive coronary angiography with multidetector CT allows both assessment of luminal stenosis and subclinical disease of arterial wall. Large trails are missing now to understand and present what will be the role of this technology in the comprehensive assessment of patients, suspected of having CAD. Based on experience and current potentials we will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development

  13. Muon tomography for imaging nuclear waste and spent fuel verification

    Energy Technology Data Exchange (ETDEWEB)

    Jonkmans, G.; Anghel, V.N.P.; Thompson, M. [Atomic Energy of Canada Limited, Chalk River (Canada)

    2010-07-01

    This paper explores the use of cosmic ray muons to image the content of, and to detect high-Z special nuclear material inside, shielded containers. Cosmic ray muons are a naturally occurring form of radiation, are highly penetrating and exhibit large scattering angles on high Z materials. Specifically, we investigated how radiographic and tomographic techniques can be effective for non-invasive nuclear waste characterization and for nuclear material accountancy of spent fuel inside dry storage containers. We show that the tracking of individual muons, as they enter and exit a structure, can potentially improve the accuracy and availability of data on nuclear waste and the content of Dry Storage Containers (DSC) used for spent fuel storage at CANDU plants. This could be achieved in near real time, with the potential for unattended and remotely monitored operations. We show that the expected sensitivity to perform material accountancy, in the case of the DSC, exceeds the IAEA detection target for nuclear material accountancy. (author)

  14. Non-invasive pre-clinical MR imaging of prostate tumor hypoxia for radiation therapy prognosis

    Directory of Open Access Journals (Sweden)

    Derek White

    2014-03-01

    Full Text Available Purpose: To investigate the usefulness of Oxygen-Enhanced Magnetic Resonance Imaging (OE-MRI changes in signal intensity related to oxygen challenge for predicting tumor response to radiation therapy.Methods: Dynamic MR signal changes were acquired using Varian 4.7T small animal MR scanner prior to image-guided radiation therapy (IGRT of small (n = 6 and large subcutaneous (n = 5 prostate tumors in adult male rats. An interleaved blood-oxygen level dependent (BOLD and tissue-oxygen level dependent (TOLD data acquisition or (IBT was performed using a baseline of medical air as positive control and using medical oxygen as a breathing challenge. BOLD used a 2-D multi-slice spoiled gradient-echo with multi-echo sequence. TOLD used a 2-D multi-slice spoiled gradient-echo sequence. Voxel changes in signal intensity were determined by a correlation coefficient mapping technique. Irradiation technique planned consisted of 1F × 15 Gy AP/PA or 2F × 7.5 Gy AP/PA to the gross tumor volume (GTV. Tumor growth measurements were recorded over time to assess the response to IGRT.Results: BOLD and TOLD signals variously illustrated positive or negative impulse responses in the tumor ROI due to inhaling medical oxygen. Correlation coefficient mapping demonstrated heterogeneity in tumors after inhaling medical oxygen. BOLD and TOLD signals exhibited increased changes in signal intensities after the first fraction of dose. Multi-fractionation had minimum effect until the second fraction of dose was applied. Tumor growth delays were observed when inhaling medical oxygen during IGRT.Conclusion: OE-MRI is a non-invasive imaging modality that can provide insight to the oxygen status of tumors. Observed increase percent changes in BOLD and TOLD signal intensities after the first fraction of dose suggest tumors experienced reoxygenation. OE-MRI could be used for predicting tumor response to IGRT when using medical oxygen for increasing GTV radiosensitivity, suggesting

  15. Patient management after noninvasive cardiac imaging results from SPARC (Study of myocardial perfusion and coronary anatomy imaging roles in coronary artery disease).

    NARCIS (Netherlands)

    Hachamovitch, R.; Nutter, B.; Hlatky, M.A.; Shaw, L.J.; Ridner, M.L.; Dorbala, S.; Beanlands, R.S.; Chow, B.J.; Branscomb, E.; Chareonthaitawee, P.; Weigold, W.G.; Voros, S.; Abbara, S.; Yasuda, T.; Jacobs, J.E.; Lesser, J.; Berman, D.S.; Thomson, L.E.; Raman, S.; Heller, G.V.; Schussheim, A.; Brunken, R.; Williams, K.A.; Farkas, S.; Delbeke, D.; Schoepf, U.J.; Reichek, N.; Rabinowitz, S.; Sigman, S.R.; Patterson, R.; Corn, C.R.; White, R.; Kazerooni, E.; Corbett, J.; Bokhari, S.; Machac, J.; Guarneri, E.; Borges-Neto, S.; Millstine, J.W.; Caldwell, J.; Arrighi, J.; Hoffmann, U.; Budoff, M.; Lima, J.; Johnson, J.R.; Johnson, B.; Gaber, M.; Williams, J.A.; Foster, C.; Hainer, J.; Carli, M.F. Di

    2012-01-01

    OBJECTIVES: This study examined short-term cardiac catheterization rates and medication changes after cardiac imaging. BACKGROUND: Noninvasive cardiac imaging is widely used in coronary artery disease, but its effects on subsequent patient management are unclear. METHODS: We assessed the 90-day

  16. Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries

    NARCIS (Netherlands)

    Langerak, Susan E.; Vliegen, Hubert W.; Jukema, J. Wouter; Kunz, Patrik; Zwinderman, Aeilko H.; Lamb, Hildo J.; van der Wall, Ernst E.; de Roos, Albert

    2003-01-01

    BACKGROUND: Magnetic resonance imaging (MRI) is a potential noninvasive diagnostic tool to detect coronary artery bypass graft stenosis, but its value in clinical practice remains to be established. We investigated the value of MRI in detecting stenotic grafts, including recipient vessels. METHODS

  17. Noninvasive measurement of burn wound depth applying infrared thermal imaging (Conference Presentation)

    Science.gov (United States)

    Jaspers, Mariëlle E.; Maltha, Ilse M.; Klaessens, John H.; Vet, Henrica C.; Verdaasdonk, Rudolf M.; Zuijlen, Paul P.

    2016-02-01

    In burn wounds early discrimination between the different depths plays an important role in the treatment strategy. The remaining vasculature in the wound determines its healing potential. Non-invasive measurement tools that can identify the vascularization are therefore considered to be of high diagnostic importance. Thermography is a non-invasive technique that can accurately measure the temperature distribution over a large skin or tissue area, the temperature is a measure of the perfusion of that area. The aim of this study was to investigate the clinimetric properties (i.e. reliability and validity) of thermography for measuring burn wound depth. In a cross-sectional study with 50 burn wounds of 35 patients, the inter-observer reliability and the validity between thermography and Laser Doppler Imaging were studied. With ROC curve analyses the ΔT cut-off point for different burn wound depths were determined. The inter-observer reliability, expressed by an intra-class correlation coefficient of 0.99, was found to be excellent. In terms of validity, a ΔT cut-off point of 0.96°C (sensitivity 71%; specificity 79%) differentiates between a superficial partial-thickness and deep partial-thickness burn. A ΔT cut-off point of -0.80°C (sensitivity 70%; specificity 74%) could differentiate between a deep partial-thickness and a full-thickness burn wound. This study demonstrates that thermography is a reliable method in the assessment of burn wound depths. In addition, thermography was reasonably able to discriminate among different burn wound depths, indicating its potential use as a diagnostic tool in clinical burn practice.

  18. Non-Invasive Detection of Lung Inflammation by Near-Infrared Fluorescence Imaging Using Bimodal Liposomes.

    Science.gov (United States)

    Desu, Hari R; Wood, George C; Thoma, Laura A

    2016-01-01

    Acute lung injury (ALI) and its more severe form, acute respiratory distress syndrome results in respiratory obstruction and severe lung inflammation. Critical characteristics of ALI are alveolar edema, infiltration of leukocytes (neutrophils and monocytes), release of pro-inflammatory cytokines and chemokines into broncho-alveolar lavage fluid, and activation of integrin receptors. The purpose of the study was to demonstrate non-invasive detection of lung inflammation using integrin receptor targeted fluorescence liposomes. An inflammation similar to that observed in ALI was elicited in rodents by intra-tracheal instillation of interleukin-1beta (IL-1beta). Cyclic arginine glycine-(D)-aspartic acid-peptide (cRGD-peptide) grafted fluorescence liposomes were administered to ALI induced male Sprague-Dawley rats for targeting lung integrin receptors. Near-infrared fluorescence imaging (NIRFI) was applied for visualization and quantitation of lung inflammation. NIRFI signals were correlated with inflammatory cellular and biochemical markers of lungs. A positive correlation was observed between NIRF signals and lung inflammation markers. Compared to control group, an intense NIRF signal was observed in ALI induced rats in the window 6-24 h post-IL-1beta instillation. Interaction of integrin receptors with targeted liposomes was assumed to contribute to intense NIRF signal. RT-PCR studies showed an elevated lung expression of alphavbeta5 integrin receptors, 12 h post-IL-1beta instillation. In vitro studies demonstrated integrin receptor specificity of targeted liposomes. These targeted liposomes showed binding to alphavbeta5 integrin receptors expressed on alveolar cells. Non-invasive detection of lung inflammation was demonstrated using a combination of integrin receptor targeting and NIRFI.

  19. Molecular imaging: a new approach to nuclear cardiology

    International Nuclear Information System (INIS)

    Dobrucki, L.W.; Sinusas, A.J.

    2005-01-01

    Nuclear cardiology has historically played an important role in detection of cardiovascular disease as well as risk statification. With the growth of molecular biology have come new therapeutic interventions and the requirement for new diagnostic imaging approaches. Noninvasive targeted radiotracer based as well as transporter gene imaging strategies are evolving to meet these new needs, but require the development of an interdisciplinary approach which focuses on molecular processes, as well as the pathogenesis and progression of disease. This progress has been made possible with the availability of transgenic animal models along with many technological advances. Future adaptations of the developing experimental procedures and instrumentations will allow for the smooth translation and application to clinical practice. This review is intended as a brief overview on the subject molecular imaging. Basic concepts and historical perspective of molecular imaging will be reviewed first, followed by description of current technology, and concluding with current applications in cardiology. The emphasis will be on the use of both single photon emission computed tomography (SPECT) and positron emission tomography (PET) radiotracers, although other imaging modalities will be also briefly discussed. The specific approaches presented here will include receptor-based and reporter gene imaging of natural and therapeutical angiogenesis

  20. Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.

    Science.gov (United States)

    Romero, Cesar A; Cabral, Glauber; Knight, Robert A; Ding, Guangliang; Peterson, Edward L; Carretero, Oscar A

    2018-01-01

    Renal blood flow (RBF) provides important information regarding renal physiology and nephropathies. Arterial spin labeling-magnetic resonance imaging (ASL-MRI) is a noninvasive method of measuring blood flow without exogenous contrast media. However, low signal-to-noise ratio and respiratory motion artifacts are challenges for RBF measurements in small animals. Our objective was to evaluate the feasibility and reproducibility of RBF measurements by ASL-MRI using respiratory-gating and navigator correction methods to reduce motion artifacts. ASL-MRI images were obtained from the kidneys of Sprague-Dawley (SD) rats on a 7-Tesla Varian MRI system with a spin-echo imaging sequence. After 4 days, the study was repeated to evaluate its reproducibility. RBF was also measured in animals under unilateral nephrectomy and in renal artery stenosis (RST) to evaluate the sensitivity in high and low RBF models, respectively. RBF was also evaluated in Dahl salt-sensitive (SS) rats and spontaneous hypertensive rats (SHR). In SD rats, the cortical RBFs (cRBF) were 305 ± 59 and 271.8 ± 39 ml·min -1 ·100 g tissue -1 in the right and left kidneys, respectively. Retest analysis revealed no differences ( P = 0.2). The test-retest reliability coefficient was 92 ± 5%. The cRBFs before and after the nephrectomy were 296.8 ± 30 and 428.2 ± 45 ml·min -1 ·100 g tissue -1 ( P = 0.02), respectively. The kidneys with RST exhibited a cRBF decrease compared with sham animals (86 ± 17.6 vs. 198 ± 33.7 ml·min -1 ·100 g tissue -1 ; P < 0.01). The cRBFs in SD, Dahl-SS, and SHR rats were not different ( P = 0.35). We conclude that ASL-MRI performed with navigator correction and respiratory gating is a feasible and reliable noninvasive method for measuring RBF in rats.

  1. Proceedings of Joint International Symposium on the role of noninvasive imaging modalities in clinical decision making of coronary artery disease

    International Nuclear Information System (INIS)

    Mena, I.G.; Strauss, H.W.

    1986-01-01

    This report contains ten papers on the use of noninvasive imaging in clinical diagnosis and decision making. Topics include a cost analysis of magnetic resonance imaging in medical technology, diagnostic uses of MRI in chronic coronary artery disease, clinical applications of cine computed tomography, the use of PET as a clinical tool, and the use of echocardiography in coronary artery disease. Individual papers are processed separately for the data base

  2. Noninvasive imaging technologies reveal edema toxin as a key virulence factor in anthrax.

    Science.gov (United States)

    Dumetz, Fabien; Jouvion, Grégory; Khun, Huot; Glomski, Ian Justin; Corre, Jean-Philippe; Rougeaux, Clémence; Tang, Wei-Jen; Mock, Michèle; Huerre, Michel; Goossens, Pierre Louis

    2011-06-01

    Powerful noninvasive imaging technologies enable real-time tracking of pathogen-host interactions in vivo, giving access to previously elusive events. We visualized the interactions between wild-type Bacillus anthracis and its host during a spore infection through bioluminescence imaging coupled with histology. We show that edema toxin plays a central role in virulence in guinea pigs and during inhalational infection in mice. Edema toxin (ET), but not lethal toxin (LT), markedly modified the patterns of bacterial dissemination leading, to apparent direct dissemination to the spleen and provoking apoptosis of lymphoid cells. Each toxin alone provoked particular histological lesions in the spleen. When ET and LT are produced together during infection, a specific temporal pattern of lesion developed, with early lesions typical of LT, followed at a later stage by lesions typical of ET. Our study provides new insights into the complex spatial and temporal effects of B. anthracis toxins in the infected host, suggesting a greater role than previously suspected for ET in anthrax and suggesting that therapeutic targeting of ET contributes to protection. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  3. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

    Science.gov (United States)

    Hynynen, Kullervo; Jones, Ryan M

    2016-09-07

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.

  4. Steato-Score: Non-Invasive Quantitative Assessment of Liver Fat by Ultrasound Imaging.

    Science.gov (United States)

    Di Lascio, Nicole; Avigo, Cinzia; Salvati, Antonio; Martini, Nicola; Ragucci, Monica; Monti, Serena; Prinster, Anna; Chiappino, Dante; Mancini, Marcello; D'Elia, Domenico; Ghiadoni, Lorenzo; Bonino, Ferruccio; Brunetto, Maurizia R; Faita, Francesco

    2018-05-04

    Non-alcoholic fatty liver disease is becoming a global epidemic. The aim of this study was to develop a system for assessing liver fat content based on ultrasound images. Magnetic resonance spectroscopy measurements were obtained in 61 patients and the controlled attenuation parameter in 54. Ultrasound images were acquired for all 115 participants and used to calculate the hepatic/renal ratio, hepatic/portal vein ratio, attenuation rate, diaphragm visualization and portal vein wall visualization. The Steato-score was obtained by combining these five parameters. Magnetic resonance spectroscopy measurements were significantly correlated with hepatic/renal ratio, hepatic/portal vein ratio, attenuation rate, diaphragm visualization and portal vein wall visualization; Steato-score was dependent on hepatic/renal ratio, attenuation rate and diaphragm visualization. Area under the receiver operating characteristic curve was equal to 0.98, with 89% sensitivity and 94% specificity. Controlled attenuation parameter values were significantly correlated with hepatic/renal ratio, attenuation rate, diaphragm visualization and Steato-score; the area under the curve was 0.79. This system could be a valid alternative as a non-invasive, simple and inexpensive assessment of intrahepatic fat. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  5. Noninvasive imaging in the assessment and prevention of coronary heart disease

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis Roberto; Peix Gonzalez, Amalia; Valiente Mustelier, Juan

    2011-01-01

    Echocardiography, multidetector computed tomography, magnetic resonance imaging, and nuclear cardiology can all help prevent coronary heart disease. Echocardiography can identify asymptomatic individuals who are at risk of coronary disease and who should receive aggressive preventative therapy by providing data on the carotid intima-media thickness, arterial stiffness and flow-mediated dilatation of the brachial artery. The calcium score is an independent predictor of cardiac events that influences clinical risk scores such as the Framingham risk score. By using multidetector computed tomography or magnetic resonance imaging for coronary angiography, it is possible to visualize both the lumen and vessel walls of coronary arteries and to discriminate between calcified and noncalcified atherosclerotic plaque before invasive coronary angiography is performed. With nuclear cardiology, the functional effects of atherosclerotic lesions can be evaluated by assessing perfusion and ventricular function simultaneously

  6. Nuclear Medicine Image Display. Chapter 14

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, H. [Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna (Austria)

    2014-12-15

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  7. Nuclear Medicine Image Display. Chapter 14

    International Nuclear Information System (INIS)

    Bergmann, H.

    2014-01-01

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  8. Syntheses of Radioiodinated Pyrimidine-2,4,6-Triones as Potential Agents for Non-Invasive Imaging of Matrix Metalloproteinases

    Directory of Open Access Journals (Sweden)

    Hans-Jörg Breyholz

    2017-05-01

    Full Text Available Dysregulated expression or activation of matrix metalloproteinases (MMPs is observed in many kinds of live-threatening diseases. Therefore, MMP imaging for example with radiolabelled MMP inhibitors (MMPIs potentially represents a valuable tool for clinical diagnostics using non-invasive single photon emission computed tomography (SPECT or positron emission tomography (PET imaging. This work includes the organic chemical syntheses and in vitro evaluation of five iodinated barbiturate based MMPIs and the selection of derivative 9 for radiosyntheses of isotopologues [123I]9 potentially useful for MMP SPECT imaging and [124I]9 for MMP PET imaging.

  9. Nuclear Medicine Imaging Devices. Chapter 11

    Energy Technology Data Exchange (ETDEWEB)

    Lodge, M. A.; Frey, E. C. [Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, MD (United States)

    2014-12-15

    Imaging forms an important part of nuclear medicine and a number of different imaging devices have been developed. This chapter describes the principles and technological characteristics of the main imaging devices used in nuclear medicine. The two major categories are gamma camera systems and positron emission tomography (PET) systems. The former are used to image γ rays emitted by any nuclide, while the latter exploit the directional correlation between annihilation photons emitted by positron decay. The first section of this chapter discusses the principal components of gamma cameras and how they are used to form 2-D planar images as well as 3-D tomographic images (single photon emission computed tomography (SPECT)). The second section describes related instrumentation that has been optimized for PET data acquisition. A major advance in nuclear medicine was achieved with the introduction of multi-modality imaging systems including SPECT/computed tomography (CT) and PET/CT. In these systems, the CT images can be used to provide an anatomical context for the functional nuclear medicine images and allow for attenuation compensation. The third section in this chapter provides a discussion of the principles of these devices.

  10. Non-invasive In Vivo Fluorescence Optical Imaging of Inflammatory MMP Activity Using an Activatable Fluorescent Imaging Agent.

    Science.gov (United States)

    Schwenck, Johannes; Maier, Florian C; Kneilling, Manfred; Wiehr, Stefan; Fuchs, Kerstin

    2017-05-08

    This paper describes a non-invasive method for imaging matrix metalloproteinases (MMP)-activity by an activatable fluorescent probe, via in vivo fluorescence optical imaging (OI), in two different mouse models of inflammation: a rheumatoid arthritis (RA) and a contact hypersensitivity reaction (CHR) model. Light with a wavelength in the near infrared (NIR) window (650 - 950 nm) allows a deeper tissue penetration and minimal signal absorption compared to wavelengths below 650 nm. The major advantages using fluorescence OI is that it is cheap, fast and easy to implement in different animal models. Activatable fluorescent probes are optically silent in their inactivated states, but become highly fluorescent when activated by a protease. Activated MMPs lead to tissue destruction and play an important role for disease progression in delayed-type hypersensitivity reactions (DTHRs) such as RA and CHR. Furthermore, MMPs are the key proteases for cartilage and bone degradation and are induced by macrophages, fibroblasts and chondrocytes in response to pro-inflammatory cytokines. Here we use a probe that is activated by the key MMPs like MMP-2, -3, -9 and -13 and describe an imaging protocol for near infrared fluorescence OI of MMP activity in RA and control mice 6 days after disease induction as well as in mice with acute (1x challenge) and chronic (5x challenge) CHR on the right ear compared to healthy ears.

  11. Infection imaging in nuclear medicine

    African Journals Online (AJOL)

    osteomyelitis, particularly in children without previous trauma to their ... Anatomical imaging (such as X-rays, ... bacterial pneumonia, whereas diffuse ... imaging is superior to Ga-67 for the detection ... Clinical value of FDG PET in patients with.

  12. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.

    1980-01-01

    This project deals with imaging systems in nuclear medicine and image evaluation and is presented as four subprojects. The goal of the first subproject is to improve diagnositc image quality by development of a general computer code for optimizing collimator design. The second subproject deals with a secondary emission and fluorescence technique for thyroid scanning while the third subproject emphasizes the need for more sophisticated image processing systems such as coherent optical spatial filtering systems and digital image processing. The fourth subproject presents a new approach for processing image data by taking into account the energy of each detected gamma-ray photon

  13. Technetium-99m labeled antisense oligonucleotide-noninvasive tumor imaging in mice

    International Nuclear Information System (INIS)

    Qin, G.M.; Zhang, Y.X.; An, R.; Gao, Z.R.; Cao, W.; Cao, G.X.; Hnatowich, D.J.

    2002-01-01

    Single-stranded RNA and DNA oligonucleotides may be useful as radiopharmaceuticals for antisense and other in vivo applications if convenient methods for stably attaching radionuclides such as 99m Tc can be developed. The c-myc oncogene works in cooperation with other oncogenes in a variety of malignant tumors. The concentration of c-myc messenger RNA increases rapidly 30 to 50 fold during DNA synthesis, thus making it a suitable target for following the progression of malignancy by noninvasive imaging with radiolabeled antisense oligonucleotide probes. Methods: 1 Oligonucleotide Conjugation: A solution of single stranded amine-derivatized DNA (100-1000μg) was prepared at a concentration of 2 mg/ml in 0.25M sodium bicarbonate, 1 M sodium chloride, 1mM EDTA, pH8.5. 2 Oligonucleotide Labeling: A fresh 50mg/ml solution of sodium tartrate was prepared in sterile 0.5 M ammonium The ability of the labeled DNA to hybridize to its complement was analyzed by Sep-Pak column chromatography before and after the addition of the complementary DNA. 3 Biodistribution and Tumor Imaging Studies: A colony of KM mice (15-20g) were inoculated with 1x10 6 Ehrlich carcinoma tumor cells in the right thigh, and the tumors were allowed to grow for 6-7 days to a size of 1.0-1.5 cm in diameter. Biodistribution studies were performed in 32 KM mice after 50 μCi per mouse of 99m Tc-labeled oncogene probes were injected intravenously. A total of 8 mice were injected intravenously in the tail vein with 1-2 mCi of 99m Tc-labeled sense or antisense probes, immobilized with ketamine hydrochloride and imaged periodically from 0.5hr to 24hr with a gamma camera. Results: Essentially complete conjugation was achieved by reverse-phase Sep-Pak C18 chromatography analysis. The labeled antisense DNA still remained the ability to hybridize with its complementary DNA. The highest accumulation of label was in the liver first, with the kidney and small bowel next. The injected activity localized in the lesion

  14. Interventional magnetic resonance imaging - non-invasive imaging for interventions; Interventionelle Magnetresonanztomographie - nichtinvasive Bildgebung fuer Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Buecker, A.; Adam, G.; Neuerburg, J.M.; Glowinski, A.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Medizinische Fakultaet

    2000-02-01

    As a prerequisite for MR-guidance of interventional procedures, instruments have to be well depicted in the MR image without obscuring or distorting the underlying anatomy. For non-vascular interventions the imaging speed has to be in the range of seconds while control of vascular interventions requires real time imaging speed. The imaging contrast has to be maintained as well as a high spatial resolution. Furthermore, sufficient patient access has to be provided by the MR scanner. Neither an ideal magnet nor the optimal single sequence are available to fulfill the above-mentioned criteria. The type of sequence - gradient echo versus spin echo - together with changing of the echo time and phase encording direction will ensure an appropriate size of the artifact and thereby of the appearance of the instrument in the MR image. The feasibility of non-vascular MR-guided interventions has been proved at field strengths ranging from 0.064 T to 1.5 T. Bone biopsies, soft tissue biopsies, drainages, and control of interstitial thermo- and cryotherapy have been reported. For vascular interventions, different real time MR strategies are currently under investigation. The development of dedicated catheters and guide wires has enabled MR-guided dilatations, stenting, placement of vena cava filters, and TIPS procedures. Considering the fast progress being made in this field, there can be no question that interventional MRI will become a well-accepted clinical tool offering potential advantages such as excellent soft tissue contrast, multiplanar imaging, flow measurements, high resolution imaging of vessel walls, and lack of ionizing radiation. (orig.) [German] Zur Durchfuehrung MR-gesteuerter Interventionen muessen interventionelle Instrumente gut sichtbar, aber ohne stoerende Artefakte darstellbar sein. Die Geschwindigkeit der Bilderstellung sollte fuer nichtvaskulaere Interventionen im Sekundenbereich liegen und fuer vaskulaere Interventionen Echtzeitbildgebung liefern. Weder

  15. Nuclear Medicine Imaging of Neuroendocrine Tumors

    NARCIS (Netherlands)

    Brabander, Tessa; Kwekkeboom, Dik J.; Feelders, Richard A.; Brouwers, Adrienne H.; Teunissen, Jaap J. M.; Papotti, M; DeHerder, WW

    2015-01-01

    An important role is reserved for nuclear imaging techniques in the imaging of neuroendocrine tumors (NETs). Somatostatin receptor scintigraphy (SRS) with In-111-DTPA-octreotide is currently the most important tracer in the diagnosis, staging and selection for peptide receptor radionuclide therapy

  16. Nuclear imaging: A powerful novel approach for tuberculosis

    International Nuclear Information System (INIS)

    Johnson, Daniel H.; Via, Laura E.; Kim, Peter; Laddy, Dominick; Lau, Chuen-Yen; Weinstein, Edward A.; Jain, Sanjay

    2014-01-01

    Nearly 20 years after the World Health Organization declared tuberculosis (TB) a global public health emergency, TB still remains a major global threat with 8.6 million new cases and 1.3 million deaths annually. Mycobacterium tuberculosis adapts to a quiescent physiological state, and is notable for complex interaction with the host, producing poorly-understood disease states ranging from latent infection to fully active disease. Of the approximately 2.5 billion people latently infected with M. tuberculosis, many will develop reactivation disease (relapse), years after the initial infection. While progress has been made on some fronts, the alarming spread of multidrug-resistant, extensively drug-resistant, and more recently totally-drug resistant strains is of grave concern. New tools are urgently needed for rapidly diagnosing TB, monitoring TB treatments and to allow unique insights into disease pathogenesis. Nuclear bioimaging is a powerful, noninvasive tool that can rapidly provide three-dimensional views of disease processes deep within the body and conduct noninvasive longitudinal assessments of the same patient. In this review, we discuss the application of nuclear bioimaging to TB, including the current state of the field, considerations for radioprobe development, study of TB drug pharmacokinetics in infected tissues, and areas of research and clinical needs that could be addressed by nuclear bioimaging. These technologies are an emerging field of research, overcome several fundamental limitations of current tools, and will have a broad impact on both basic research and patient care. Beyond diagnosis and monitoring disease, these technologies will also allow unique insights into understanding disease pathogenesis; and expedite bench-to-bedside translation of new therapeutics. Finally, since molecular imaging is readily available for humans, validated tracers will become valuable tools for clinical applications

  17. In-situ Non-Invasive Imaging of Liquid-Immersed Thin Film Composite Membranes

    KAUST Repository

    Ogieglo, Wojciech

    2017-10-14

    We present a non-invasive method to directly image liquid-immersed thin film composite membranes. The approach allows accessing information not only on the lateral distribution of the coating thickness, including variations in its swelling and density, but also on the distribution of substrate porosity, roughness, accessibility of pores to liquid, and even the degree of pore intrusion related to the thin layer deposition process. The method can be particularly helpful in the fields of functional coatings or membranes to allow laterally-resolved studies under realistic application conditions thereby opening completely new research avenues. The approach is demonstrated in a study of two polymers of intrinsic microporosity, PIM-1 and PIM-6FDA-OH, coated on polyacrylonitrile support and immersed in water. Variations of the skin morphology using different coating methods (floating, spin-coating and dip-coating) are evaluated with the help of the presented method. Surfaces of at least tens of cm2 can be potentially analyzed.

  18. Gold nanoparticles for non-invasive cell tracking with CT imaging

    Science.gov (United States)

    Meir, Rinat; Betzer, Oshra; Barnoy, Eran; Motiei, Menachem; Popovtzer, Rachela

    2018-02-01

    Cell-based therapies use living cells with therapeutic traits to treat various diseases. This is a beneficial alternative for diseases that existing medicine cannot cure efficiently. However, inconsistent results in clinical trials are preventing the advancement and implementation of cell-based therapy. In order to explain such results, there is a need to discover the fate of the transplanted cells. To answer this need, we developed a technique for noninvasive in vivo cell tracking, which uses gold nanoparticles as contrast agents for CT imaging. Herein, we investigate the design principles of this technique for intramuscular transplantation of therapeutic cells. Longitudinal studies were performed, demonstrating the ability to track cells over long periods of time. As few as 500 cells could be detected and a way to quantify the number of cells visualized by CT was demonstrated. This cell-tracking technology has the potential to become an essential tool in pre-clinical studies as well as in clinical trials and advance cell therapy.

  19. Imaging of Nuclear Weapon Trainers

    Energy Technology Data Exchange (ETDEWEB)

    Schwellenbach, David [National Security Technologies, LLC. (NSTec), Mercury, NV (United States)

    2017-12-06

    The Configurable Muon Tracker (CMT) is an adaptation of the existing drift tube detector commercially available from Decision Sciences International Corporation (DSIC). NSTec engineered the CMT around commercially available drift tube assemblies to make a detector that is more versatile than previous drift tube assemblies. The CMT became operational in February 2013. Traditionally, cosmic-ray muon trackers rely on near-vertical trajectory muons for imaging. Since there are scenarios where imaging using vertical trajectory muons is not practical, NSTec designed the CMT specifically for quick configurability to track muons from any trajectory. The CMT was originally designed to be changed from vertical imaging mode to horizontal imaging mode in a few hours with access to a crane or other lifting equipment. In FY14, locations for imaging weapon trainers and SNM were identified and it was determined that lifting equipment would not typically be available in experimental areas. The CMT was further modified and a portable lifting system was developed to allow reconfiguration of the CMT without access to lifting equipment at the facility. This system was first deployed at Los Alamos National Laboratory’s W-division, where several trainers were imaged in both horizontal and vertical modes. Real-time images have been compared in both modes showing that imaging can be done in both modes with the expected longer integration time for horizontal mode. Further imaging and post processing of the data is expected to continue into early FY15.

  20. Noninvasive detection of hepatic lipidosis in dairy cows with calibrated ultrasonographic image analysis.

    Science.gov (United States)

    Starke, A; Haudum, A; Weijers, G; Herzog, K; Wohlsein, P; Beyerbach, M; de Korte, C L; Thijssen, J M; Rehage, J

    2010-07-01

    =100mg of TAG/g of FW), and 0.97 (or=100mg of TAG/g of FW). The CAUS methodology and software for digitally analyzing liver ultrasonographic images is considered feasible for noninvasive screening of fatty liver in dairy herd health programs. Using the single parameter linear regression equation might be ideal for practical applications. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. The future of cardiovascular imaging and non-invasive diagnosis. A joint statement from the European Association of Echocardiography, the Working Groups on Cardiovascular Magnetic Resonance, Computers in Cardiology, and Nuclear Cardiology, of the European Society of Cardiology, the European Association of Nuclear Medicine and the Association for European Paediatric Cardiology.

    Science.gov (United States)

    Fraser, Alan G; Buser, Peter T; Bax, Jeroen J; Dassen, Willem R; Nihoyannopoulos, Petros; Schwitter, Jürg; Knuuti, Juhani M; Höher, Martin; Bengel, Frank; Szatmári, András

    2006-08-01

    Advances in medical imaging now make it possible to investigate any patient with cardiovascular disease using multiple methods which vary widely in their technical requirements, benefits, limitations and costs. The appropriate use of alternative tests requires their integration into joint clinical diagnostic services where experts in all methods collaborate. This statement summarises the principles that should guide developments in cardiovascular diagnostic services.

  2. The future of cardiovascular imaging and non-invasive diagnosis. A joint statement from the European Association of Echocardiography, the Working Groups on Cardiovascular Magnetic Resonance, Computers in Cardiology, and Nuclear Cardiology, of the European Society of Cardiology, the European Association of Nuclear Medicine and the Association for European Paediatric Cardiology

    International Nuclear Information System (INIS)

    Fraser, Alan G.; Nihoyannopoulos, Petros; Buser, Peter T.; Schwitter, Juerg; Bax, Jeroen J.; Knuuti, Juhani M.; Dassen, Willem R.; Hoeher, Martin; Bengel, Frank; Szatmari, Andras

    2006-01-01

    Advances in medical imaging now make it possible to investigate any patient with cardiovascular disease using multiple methods which vary widely in their technical requirements, benefits, limitations and costs. The appropriate use of alternative tests requires their integration into joint clinical diagnostic services where experts in all methods collaborate. This statement summarises the principles that should guide developments in cardiovascular diagnostic services. (orig.)

  3. Myocardial viability assessment using nuclear imaging

    International Nuclear Information System (INIS)

    Matsunari, Ichiro; Hisada, Kinichi; Taki, Junichi; Nakajima, Kenichi; Tonami, Norihisa

    2003-01-01

    Myocardial assessment continues to be an issue in patients with coronary artery disease and left ventricular dysfunction. Nuclear imaging has long played an important role in this field. In particular, PET imaging using 18 F-fluorodeoxyglucose is regarded as the metabolic gold standard of tissue viability, which has been supported by a wide clinical experience. Viability assessment using SPECT techniques has gained more wide-spread clinical acceptance than PET, because it is more widely available at lower cost. Moreover, technical advances in SPECT technology such as gated-SPECT further improve the diagnostic accuracy of the test. However, other imaging techniques such as dobutamine echocardiography have recently emerged as competitors to nuclear imaging. It is also important to note that they sometimes may work in a complementary fashion to nuclear imaging, indicating that an appropriate use of these techniques may significantly improve their overall accuracy. In keeping these circumstances in mind, further efforts are necessary to further improve the diagnostic performance of nuclear imaging as a reliable viability test. (author) 107 refs

  4. Validation of Dynamic optical coherence tomography for non-invasive, in vivo microcirculation imaging of the skin

    DEFF Research Database (Denmark)

    Themstrup, L.; Welzel, Julia; Ciardo, Silvana

    2016-01-01

    Objectives: Dynamic optical coherence tomography (D-OCT) is an angiographic variation of OCT that non-invasively provides images of the in vivo microvasculature of the skin by combining conventional OCT images with flow data. The objective of this study was to investigate and report on the D.......001), and also the redness a measurements were positively correlated with the D-OCT measurements (r = 0.48; 95% CI [0.406, 0.55]). D-OCT was able to reliably image and identify morphologic changes in the vascular network consistent with the induced physiological changes of blood flow. Conclusion: This study has...... initiated validation of the use of D-OCT for imaging of skin blood flow. Our results showed that D-OCT was able to reliably image and identify changes in the skin vasculature consistent with the induced physiological blood flow changes. These basic findings support the use of D-OCT imaging for in vivo...

  5. Non-invasive retinal imaging in mice with fluorescent Scanning Laser Ophthalmoscopy and Fourier Domain Optical Coherence Tomography

    OpenAIRE

    Hossein-Javaheri, Nima

    2010-01-01

    Visualization of the internal structures of the retina is critical for clinical diagnosis and monitoring of pathology as well as for medical research investigating the root causes of retinal degeneration. The aim of this thesis is to develop multi-modal non-invasive imaging technology for studying retinal degeneration and gene therapy in mice. We have constructed a FD-OCT prototype and combined it with a Scanning Laser Ophthalmoscope (SLO) to permit real time alignment of the retinal field of...

  6. Quantitative Analysis in Nuclear Medicine Imaging

    CERN Document Server

    2006-01-01

    This book provides a review of image analysis techniques as they are applied in the field of diagnostic and therapeutic nuclear medicine. Driven in part by the remarkable increase in computing power and its ready and inexpensive availability, this is a relatively new yet rapidly expanding field. Likewise, although the use of radionuclides for diagnosis and therapy has origins dating back almost to the discovery of natural radioactivity itself, radionuclide therapy and, in particular, targeted radionuclide therapy has only recently emerged as a promising approach for therapy of cancer and, to a lesser extent, other diseases. As effort has, therefore, been made to place the reviews provided in this book in a broader context. The effort to do this is reflected by the inclusion of introductory chapters that address basic principles of nuclear medicine imaging, followed by overview of issues that are closely related to quantitative nuclear imaging and its potential role in diagnostic and therapeutic applications. ...

  7. Evaluation of biolistic gene transfer methods in vivo using non-invasive bioluminescent imaging techniques

    Directory of Open Access Journals (Sweden)

    Daniell Henry

    2011-06-01

    Full Text Available Abstract Background Gene therapy continues to hold great potential for treating many different types of disease and dysfunction. Safe and efficient techniques for gene transfer and expression in vivo are needed to enable gene therapeutic strategies to be effective in patients. Currently, the most commonly used methods employ replication-defective viral vectors for gene transfer, while physical gene transfer methods such as biolistic-mediated ("gene-gun" delivery to target tissues have not been as extensively explored. In the present study, we evaluated the efficacy of biolistic gene transfer techniques in vivo using non-invasive bioluminescent imaging (BLI methods. Results Plasmid DNA carrying the firefly luciferase (LUC reporter gene under the control of the human Cytomegalovirus (CMV promoter/enhancer was transfected into mouse skin and liver using biolistic methods. The plasmids were coupled to gold microspheres (1 μm diameter using different DNA Loading Ratios (DLRs, and "shot" into target tissues using a helium-driven gene gun. The optimal DLR was found to be in the range of 4-10. Bioluminescence was measured using an In Vivo Imaging System (IVIS-50 at various time-points following transfer. Biolistic gene transfer to mouse skin produced peak reporter gene expression one day after transfer. Expression remained detectable through four days, but declined to undetectable levels by six days following gene transfer. Maximum depth of tissue penetration following biolistic transfer to abdominal skin was 200-300 μm. Similarly, biolistic gene transfer to mouse liver in vivo also produced peak early expression followed by a decline over time. In contrast to skin, however, liver expression of the reporter gene was relatively stable 4-8 days post-biolistic gene transfer, and remained detectable for nearly two weeks. Conclusions The use of bioluminescence imaging techniques enabled efficient evaluation of reporter gene expression in vivo. Our results

  8. Nuclear cardiac imaging: Principles and applications

    Energy Technology Data Exchange (ETDEWEB)

    Iskandrian, A.S.

    1987-01-01

    This book is divided into 11 chapters. The first three provide a short description of the instrumentation, radiopharmaceuticals, and imaging techniques used in nuclear cardiology. Chapter 4 discusses exercise testing. Chapter 5 gives the theory, technical aspects, and interpretations of thallium-201 myocardial imaging and radionuclide ventriculography. The remaining chapters discuss the use of these techniques in patients with coronary artery disease, acute myocardial infarction, valvular heart disease, and other forms of cardiac disease. The author intended to emphasize the implications of nuclear cardiology procedures on patient care management and to provide a comprehensive bibliography.

  9. Nuclear cardiac imaging: Principles and applications

    International Nuclear Information System (INIS)

    Iskandrian, A.S.

    1987-01-01

    This book is divided into 11 chapters. The first three provide a short description of the instrumentation, radiopharmaceuticals, and imaging techniques used in nuclear cardiology. Chapter 4 discusses exercise testing. Chapter 5 gives the theory, technical aspects, and interpretations of thallium-201 myocardial imaging and radionuclide ventriculography. The remaining chapters discuss the use of these techniques in patients with coronary artery disease, acute myocardial infarction, valvular heart disease, and other forms of cardiac disease. The author intended to emphasize the implications of nuclear cardiology procedures on patient care management and to provide a comprehensive bibliography

  10. Improved Geologic Interpretation of Non-invasive Electrical Resistivity Imaging from In-situ Samples

    Science.gov (United States)

    Mucelli, A.; Aborn, L.; Jacob, R.; Malusis, M.; Evans, J.

    2016-12-01

    Non-invasive geophysical techniques are useful in characterizing the subsurface geology without disturbing the environment, however, the ability to interpret the subsurface is enhanced by invasive work. Since geologic materials have electrical resistivity values it allows for a geologic interpretation to be made based on variations of electrical resistivity measured by electrical resistivity imaging (ERI). This study focuses on the pre-characterization of the geologic subsurface from ERI collected adjacent to the Montandon Marsh, a wetland located near Lewisburg, PA within the West Branch of the Susquehanna River watershed. The previous invasive data, boreholes, indicate that the subsurface consists of limestone and shale bedrock overlain with sand and gravel deposits from glacial outwash and aeolian processes. The objective is to improve our understanding of the subsurface at this long-term hydrologic research site by using excavation results, specifically observed variations in geologic materials and electrical resistivity laboratory testing of subsurface samples. The pre-excavation ERI indicated that the shallow-most geologic material had a resistivity value of 100-500 ohm-m. In comparison, the laboratory testing indicated the shallow-most material had the same range of electrical resistivity values depending on saturation levels. The ERI also showed that there was an electrically conductive material, 7 to 70 ohm-m, that was interpreted to be clay and agreed with borehole data, however, the excavation revealed that at this depth range the geologic material varied from stratified clay to clay with cobbles to weathered residual clay. Excavation revealed that the subtle variations in the electrical conductive material corresponded well with the variations in the geologic material. We will use these results to reinterpret previously collected ERI data from the entire long-term research site.

  11. Noninvasive monitoring of placenta-specific transgene expression by bioluminescence imaging.

    Directory of Open Access Journals (Sweden)

    Xiujun Fan

    Full Text Available BACKGROUND: Placental dysfunction underlies numerous complications of pregnancy. A major obstacle to understanding the roles of potential mediators of placental pathology has been the absence of suitable methods for tissue-specific gene manipulation and sensitive assays for studying gene functions in the placentas of intact animals. We describe a sensitive and noninvasive method of repetitively tracking placenta-specific gene expression throughout pregnancy using lentivirus-mediated transduction of optical reporter genes in mouse blastocysts. METHODOLOGY/PRINCIPAL FINDINGS: Zona-free blastocysts were incubated with lentivirus expressing firefly luciferase (Fluc and Tomato fluorescent fusion protein for trophectoderm-specific infection and transplanted into day 3 pseudopregnant recipients (GD3. Animals were examined for Fluc expression by live bioluminescence imaging (BLI at different points during pregnancy, and the placentas were examined for tomato expression in different cell types on GD18. In another set of experiments, blastocysts with maximum photon fluxes in the range of 2.0E+4 to 6.0E+4 p/s/cm(2/sr were transferred. Fluc expression was detectable in all surrogate dams by day 5 of pregnancy by live imaging, and the signal increased dramatically thereafter each day until GD12, reaching a peak at GD16 and maintaining that level through GD18. All of the placentas, but none of the fetuses, analyzed on GD18 by BLI showed different degrees of Fluc expression. However, only placentas of dams transferred with selected blastocysts showed uniform photon distribution with no significant variability of photon intensity among placentas of the same litter. Tomato expression in the placentas was limited to only trophoblast cell lineages. CONCLUSIONS/SIGNIFICANCE: These results, for the first time, demonstrate the feasibility of selecting lentivirally-transduced blastocysts for uniform gene expression in all placentas of the same litter and early

  12. Nuclear magnetic resonance imaging of the thorax

    International Nuclear Information System (INIS)

    Gamsu, G.; Webb, W.R.; Sheldon, P.; Kaufman, L.; Crooks, L.E.; Birnberg, F.A.; Goodman, P.; Hinchcliffe, W.A.; Hedgecock, M.

    1983-01-01

    Nuclear magnetic resonance (NMR) images of the thorax were obtained in ten normal volunteers, nine patients with advanced bronchogenic carcinoma, and three patients with benign thoracic abnormalities. In normal volunteers, mediastinal and hilar structures were seen with equal frequency on NMR images and computed tomographic scans. The hila were especially well displayed on spin-echo images. Spin-echo images showed mediastinal invasion by tumor, vascular and bronchial compression and invasion, and hilar and mediastinal adenopathy. Tumor and benign abnormalities could be separated from mediastinal and hilar fat because of their longer T1 times. Lung masses and nodules as small as 1.5 cm could be seen on the spin-echo images. NMR imaging shows promise for assessment of benign and malignant mediastinal, hilar, and lung abnormalities

  13. Pioglitazone modulates vascular inflammation in atherosclerotic rabbits : noninvasive assessment with FDG-PET-CT and dynamic contrast-enhanced MR imaging

    NARCIS (Netherlands)

    Vucic, E.; Dickson, S.D.; Calcagno, C.; Rudd, J.H.F.; Moshier, E.; Hayashi, K.; Mounessa, J.S.; Roytman, M.; Moon, M.J.; Lin, J.; Tsimikas, S.; Fisher, E.A.; Nicolay, K.; Fuster, V.; Fayad, Z.A.

    2011-01-01

    Objectives We sought to determine the antiatherosclerotic properties of pioglitazone using multimethod noninvasive imaging techniques. Background Inflammation is an essential component of vulnerable or high-risk atheromas. Pioglitazone, a peroxisome proliferator-activated receptor-gamma agonist,

  14. Positron in nuclear medicine imaging

    International Nuclear Information System (INIS)

    Basu, S.

    2012-01-01

    The last two decades have witnessed a rapid expansion of clinical indications of positron emission tomography (PET) based imaging in assessing a wide range of disorders influencing their clinical management. This is primarily based upon a large dataset of evidence that has been generated over the years. The impact has been most remarkable in the field of cancer, where it takes a pivotal role in the decision making (at initial diagnosis, early response assessment and following completion of therapeutic intervention) of a number of important malignancies. The concept of PET based personalized cancer medicine is an evolving and attractive proposition that has gained significant momentum in recent years. The non-oncological applications of PET and PET/CT are in (A) Cardiovascular Diseases (e.g. Myocardial Viability, Flow reserve with PET Perfusion Imaging and atherosclerosis imaging); (B) Neuropsychiatric disorders (e.g. Dementia, Epileptic Focus detection, Parkinson's Disease, Hyperkinetic Movement Disorders and Psychiatric diseases); (C) Infection and Inflammatory Disorders (e.g. Pyrexia of Unknown origin, complicated Diabetic Foot, Periprosthetic Infection, Tuberculosis, Sarcoidosis, Vasculitic disorders etc). Apart from these, there are certain novel clinical applications where it is undergoing critical evaluation in various large and small scale studies across several centres across the world. The modality represents a classical example of a successful translational research of recent times with a revolutionary and far-reaching impact in the field of medicine. (author)

  15. Impact of Reclassification on Thyroid Nodules with Architectural Atypia: From Non-Invasive Encapsulated Follicular Variant Papillary Thyroid Carcinomas to Non-Invasive Follicular Thyroid Neoplasm with Papillary-Like Nuclear Features.

    Directory of Open Access Journals (Sweden)

    Min Ji Jeon

    Full Text Available The follicular variant of papillary thyroid cancer (FVPTC, especially the encapsulated non-invasive subtype, is a controversial entity. Recent study suggested using 'non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP' for these indolent carcinomas. We evaluated the impact of reclassification from non-invasive encapsulated FVPTCs (EFVPTCs to NIFTPs in the diagnosis of thyroid nodules with architectural atypia.We reviewed 1301 thyroid nodules with architectural atypia in core needle biopsy (CNB specimens obtained from March 2012 to February 2013. Nodules were classified into atypia of undetermined significance with architectural atypia (AUS-A, 984, 76% or follicular neoplasm/suspicious for a follicular neoplasm (FN/SFN, 317, 24%. Among them, diagnostic surgery was performed in 384 nodules (30%.In total, 160 nodules (42% presented final malignant diagnoses including 39 non-invasive encapsulated FVPTCs (10%. The malignancy rate was estimated to be 7-35% in AUS-A nodules and 28-49% in FN/SFN nodules. After reclassification, the malignancy rate was much decreased and estimated to be 5-24% in AUS-A nodules, and 23-39% in FN/SFN nodules. Thyroid nodules with final malignant diagnoses were significantly more likely to have a FN/SFN CNB diagnosis, malignant US features and concomitant nuclear atypia in CNB specimens. However, these factors could not differentiate NIFTPs from other malignancies.After reclassification of non-invasive EFVPTCs to NIFTPs, the malignancy rate of thyroid nodules with architectural atypia in CNB specimens was decreased. However, there were no preoperative factors differentiating other malignancies from NIFTPs. The presence of malignant US features or concomitant nuclear atypia might help clinicians deciding diagnostic surgery but, these features also might indicate NIFTPs.

  16. Nuclear medicine imaging. An encyclopedic dictionary

    International Nuclear Information System (INIS)

    Thie, Joseph A.

    2012-01-01

    The rapidly growing and somewhat complex area of nuclear medicine imaging receives only limited attention in broad-based medical dictionaries. This encyclopedic dictionary is intended to fill the gap. More than 400 entries of between one and three paragraphs are included, defining and carefully explaining terms in an appropriate degree of detail. The dictionary encompasses concepts used in planar, SPECT, and PET imaging protocols and covers both scanner operations and popular data analysis approaches. In spite of the mathematical complexities in the acquisition and analysis of images, the explanations given are kept simple and easy to understand; in addition, many helpful concrete examples are provided. Nuclear Medicine Imaging: An Encyclopedic Dictionary will be ideal for those who wish to obtain a rapid grasp of a concept beyond a definition of a few words but do not want to resort to a time-consuming search of the reference literature. The almost tutorial-like style accommodates the needs of students, nuclear medicine technologists, and varieties of other medical professionals who interface with specialists within nuclear medicine.

  17. Noninvasive cardiac activation imaging of ventricular arrhythmias during drug-induced QT prolongation in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; Zhou, Zhaoye; He, Bin

    2013-10-01

    Imaging myocardial activation from noninvasive body surface potentials promises to aid in both cardiovascular research and clinical medicine. To investigate the ability of a noninvasive 3-dimensional cardiac electrical imaging technique for characterizing the activation patterns of dynamically changing ventricular arrhythmias during drug-induced QT prolongation in rabbits. Simultaneous body surface potential mapping and 3-dimensional intracardiac mapping were performed in a closed-chest condition in 8 rabbits. Data analysis was performed on premature ventricular complexes, couplets, and torsades de pointes (TdP) induced during intravenous administration of clofilium and phenylephrine with combinations of various infusion rates. The drug infusion led to a significant increase in the QT interval (from 175 ± 7 to 274 ± 31 ms) and rate-corrected QT interval (from 183 ± 5 to 262 ± 21 ms) during the first dose cycle. All the ectopic beats initiated by a focal activation pattern. The initial beat of TdPs arose at the focal site, whereas the subsequent beats were due to focal activity from different sites or 2 competing focal sites. The imaged results captured the dynamic shift of activation patterns and were in good correlation with the simultaneous measurements, with a correlation coefficient of 0.65 ± 0.02 averaged over 111 ectopic beats. Sites of initial activation were localized to be ~5 mm from the directly measured initiation sites. The 3-dimensional cardiac electrical imaging technique could localize the origin of activation and image activation sequence of TdP during QT prolongation induced by clofilium and phenylephrine in rabbits. It offers the potential to noninvasively investigate the proarrhythmic effects of drug infusion and assess the mechanisms of arrhythmias on a beat-to-beat basis. © 2013 Heart Rhythm Society. All rights reserved.

  18. Combination of radiological and nuclear medical imaging in animals: an overview about the today's possibilities

    International Nuclear Information System (INIS)

    Behe, M.; Keil, B.; Kiessling, A.; Heverhagen, J.T.; Alfke, H.; Boehm, I.; Gotthardt, M.

    2007-01-01

    Molecular imaging of small animals has made considerable progress in the last years. Various research fields are interested in imaging small animals due to the lower numbers of animals per experiment. This has advantages with respect to financial, ethical and research aspects. Non-invasive imaging allows examination of one animal several times during the same experiment. This makes it possible to follow a pathological process in the same animal over time. However, the radiological methods used such as magnetic resonance imaging or computed tomography as well as the nuclear medicine methods such as single photon emission computed tomography or positron emission tomography suffer from disadvantages. Molecular aspects are limited in the radiological methods while anatomical localization is difficult in nuclear medicine. The fusion of these methods leads to additional information. This review shows today's possibilities with their advantages as well as disadvantages. (orig.)

  19. Algorithms of image processing in nuclear medicine

    International Nuclear Information System (INIS)

    Oliveira, V.A.

    1990-01-01

    The problem of image restoration from noisy measurements as encountered in Nuclear Medicine is considered. A new approach for treating the measurements wherein they are represented by a spatial noncausal interaction model prior to maximum entropy restoration is given. This model describes the statistical dependence among the image values and their neighbourhood. The particular application of the algorithms presented here relates to gamma ray imaging systems, and is aimed at improving the resolution-noise suppression product. Results for actual gamma camera data are presented and compared with more conventional techniques. (author)

  20. Image cytometry: nuclear and chromosomal DNA quantification.

    Science.gov (United States)

    Carvalho, Carlos Roberto; Clarindo, Wellington Ronildo; Abreu, Isabella Santiago

    2011-01-01

    Image cytometry (ICM) associates microscopy, digital image and software technologies, and has been particularly useful in spatial and densitometric cytological analyses, such as DNA ploidy and DNA content measurements. Basically, ICM integrates methodologies of optical microscopy calibration, standard density filters, digital CCD camera, and image analysis softwares for quantitative applications. Apart from all system calibration and setup, cytological protocols must provide good slide preparations for efficient and reliable ICM analysis. In this chapter, procedures for ICM applications employed in our laboratory are described. Protocols shown here for human DNA ploidy determination and quantification of nuclear and chromosomal DNA content in plants could be used as described, or adapted for other studies.

  1. Development of nuclear imaging instrument and software

    International Nuclear Information System (INIS)

    Kim, Jang Hee; Chung Jae Myung; Nam, Sang Won; Chang, Hyung Uk

    1999-03-01

    In the medical diagnosis, the nuclear medical instrument using the radioactive isotope are commonly utilized. In the foreign countries, the medical application and development of the most advanced nuclear medical instrument such as Single Photon Emission Computer Tomography (SPECT) and position emission tomograph (PET), have been extensively carried out. However, in Korea, such highly expensive instruments have been all, imported, paying foreign currency. Since 1997, much efforts, the development of the radio nuclide medical instrument, the drive of the domestic production, etc. have been made to establish our own technologies and to balance the international payments under the support of the Ministry of Science and Technology. At present time, 180 nuclear imaging instruments are now in operation and 60 of them are analog camera. In analog camera, the vector X-Y monitor is need for are image display. Since the analog camera, signal can not be process in the digital form, we have difficulties to transfer and store the image data. The image displayed at the monitor must be stored in the form of polaroid or X ray film. In order to discard these disadvantages, if we developed the computer interface system, the performance analog camera will be comparable with that of the digital camera. The final objective of the research is that using the interface system developed in this research, we reconstruct the image data transmitted to the personal computer in the form of the generalized data file

  2. Evaluation of non-invasive multispectral imaging as a tool for measuring the effect of systemic therapy in Kaposi sarcoma.

    Directory of Open Access Journals (Sweden)

    Jana M Kainerstorfer

    Full Text Available Diffuse multi-spectral imaging has been evaluated as a potential non-invasive marker of tumor response. Multi-spectral images of Kaposi sarcoma skin lesions were taken over the course of treatment, and blood volume and oxygenation concentration maps were obtained through principal component analysis (PCA of the data. These images were compared with clinical and pathological responses determined by conventional means. We demonstrate that cutaneous lesions have increased blood volume concentration and that changes in this parameter are a reliable indicator of treatment efficacy, differentiating responders and non-responders. Blood volume decreased by at least 20% in all lesions that responded by clinical criteria and increased in the two lesions that did not respond clinically. Responses as assessed by multi-spectral imaging also generally correlated with overall patient clinical response assessment, were often detectable earlier in the course of therapy, and are less subject to observer variability than conventional clinical assessment. Tissue oxygenation was more variable, with lesions often showing decreased oxygenation in the center surrounded by a zone of increased oxygenation. This technique could potentially be a clinically useful supplement to existing response assessment in KS, providing an early, quantitative, and non-invasive marker of treatment effect.

  3. Nuclear imaging using Fuji Computed Radiography

    International Nuclear Information System (INIS)

    Yodono, Hiraku; Tarusawa, Nobuko; Katto, Keiichi; Miyakawa, Takayoshi; Watanabe, Sadao; Shinozaki, Tatsuyo

    1988-01-01

    We studied the feasibility of the Fuji Computed Radiography system (FCR) in nuclear medicine. The basic principle of the system is the conversion of the X-ray energy pattern into digital signals utilizing scanning laser stimulated luminescence. A Rollo phantom filled with 12 mCi of Tc-99m pertechnetate was used in this study. In imaging by the FCR, a low energy high resolution parallel hole collimator for a gamma camera was placed over the phantom and photons through the collimator were stored on a single imaging plate (IP) or 3 IPs covered by the lead plate, 0.3 mm in thickness. For imaging, it took 30 minutes by a single IP and 20 minutes by 3 IPs with the lead plate respectively. Each image of the phantom by the FCR was compared with that of obtained by a gamma camera. The image by a single IP was inferior in quality than that of by a gamma camera. However using 3 IPs with the lead plate, same quality image as by a gamma camera was obtained. The image by 3 IPs is similar to that of by 3 IPs with the lead plate. Based on the results, we performed liver and lung imaging by FCR using 3 IPs. The imaging time is twenty minutes. The images obtained with FCR are as good as the scinticamera image. However it has two major flawes in that the sensitivity is poor and the imaging time is long. Furthermore, at present this method can only be employed for static imaging. However we feel that future improvements in the FCR system will overcome these problems. (author)

  4. Application of quantum dot nanoparticles for potential non-invasive bio-imaging of mammalian spermatozoa

    Science.gov (United States)

    Various obstacles are encountered by mammalian spermatozoa during their journey through the female genital tract, and only few or none will reach the site of fertilization. Currently, there are limited technical approaches for non-invasive investigation of spermatozoa migration after insemination. A...

  5. Novel imaging techniques for the nuclear microprobe

    International Nuclear Information System (INIS)

    Saint, A.

    1998-01-01

    Many of the developments of the scanning electron microscope (SEM) have been paralleled during the development of the scanning nuclear microprobe. Secondary electrons were used in the early development of both devices to provide specimen imaging due to the large numbers of secondaries produced per incident charged particle. Other imaging contrast techniques have also been developed on both machines. These include X-ray analysis, scattering contrast, transmission microscopy, channelling induced charge and others. The 'cross-section dependent' imaging techniques such as PIXE, RBS, NRA, etc., rely on the beam current on target for a given resolution. This has prompted research and development of brighter ion sources to maintain probe resolution at high beam current. Higher beam current bring problems with beam damage to the specimen. Low beam current techniques however rely on high countrate data collection systems, but this is only for spectroscopy. To produce an image we can increase beam currents to produce live-time images for specimen manipulation and observation. The work presented here will focus on some developments in live-time imaging with a nuclear micro probe that have taken place recently at the School of Physics, Microanalytical Research Centre (MARC), University of Melbourne

  6. Nuclear medicine imaging in endocarditis

    International Nuclear Information System (INIS)

    Ivancevic, V.; Munz, D.L.

    1999-01-01

    Infective endocarditis is a serious disease which requires early diagnosis and adequate therapy. Echocardiography plays a key role in diagnosis and follow-up. Subacute infective endocarditis, however, is often difficult to prove echocardiographically due to its more subtle morphological changes. Also, echocardiography cannot reliably differentiate florid vegetations from residual structural changes of the affected valves in cured patients. Therefor, scintigraphy of infection and inflammation has been investigated as a complementary tool in diagnosis and follow-up of infective endocarditis. Immunoscintigraphy with the 99m Tc labelled anti granulocyte antibody in SPECT technique is complementary to echocardiography and seems to assess the floridity of the underlying inflammatory process. The combined use of both imaging modalities allows detection of virtually all cases of subacute infective endocarditis. SPECT immunoscintigraphy with the anti granulocyte antibody seems useful in doubtful cases of infective endocarditis, especially, if echocardiography is non-diagnostic and valve pathology pre-existing. the method may be used for follow-up and monitoring antibiotic therapy

  7. Nuclear medicine imaging in endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Ivancevic, V.; Munz, D.L. (Univ. Hospital Charite' , Humboldt Univ., Berlin (Germany). Clinic for Nuclear Medicine)

    1999-03-01

    Infective endocarditis is a serious disease which requires early diagnosis and adequate therapy. Echocardiography plays a key role in diagnosis and follow-up. Subacute infective endocarditis, however, is often difficult to prove echocardiographically due to its more subtle morphological changes. Also, echocardiography cannot reliably differentiate florid vegetations from residual structural changes of the affected valves in cured patients. Therefor, scintigraphy of infection and inflammation has been investigated as a complementary tool in diagnosis and follow-up of infective endocarditis. Immunoscintigraphy with the [sup 99m]Tc labelled anti granulocyte antibody in SPECT technique is complementary to echocardiography and seems to assess the floridity of the underlying inflammatory process. The combined use of both imaging modalities allows detection of virtually all cases of subacute infective endocarditis. SPECT immunoscintigraphy with the anti granulocyte antibody seems useful in doubtful cases of infective endocarditis, especially, if echocardiography is non-diagnostic and valve pathology pre-existing. the method may be used for follow-up and monitoring antibiotic therapy.

  8. The follicular variant of papillary thyroid cancer and noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP).

    Science.gov (United States)

    Scharpf, Joseph; Kamani, Dipti; Sadow, Peter M; Randolph, Gregory W

    2017-01-01

    Noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) is a new terminology proposed for encapsulated follicular variant of papillary thyroid carcinoma (EFVPTC). Recently, thyroid cancer incidence has increased dramatically, without affecting related mortality rate. This increase is widely attributed to the intensified surveillance leading to a substantial increase in the diagnosis of small classic papillary thyroid cancers and EFVPTCs. Recent studies emphasize the indolent behavior of the EFVPTC. Recently, there has been a reclassification of EFVPTC as NIFTP, a benign entity. The financial and emotional burden of 'cancer' diagnosis and treatment can be significant. This review recapitulates the literature supporting the reclassification of EFVPTC as NIFTP, a benign entity, and reviews standardized diagnostic criteria for EFVPTC. The information highlighted in this review will affect surgical decision making and may promote the offering of hemithyroidectomy over a total thyroidectomy to some patients with 'indeterminate' cytopathological category; postoperative radioiodine ablation will not be required for NIFTP patients.

  9. Induced-Fission Imaging of Nuclear Material

    International Nuclear Information System (INIS)

    Hausladen, Paul; Blackston, Matthew A.; Mullens, James Allen; McConchie, Seth M.; Mihalczo, John T.; Bingham, Philip R.; Ericson, Milton Nance; Fabris, Lorenzo

    2010-01-01

    This paper presents initial results from development of the induced-fission imaging technique, which can be used for the purpose of measuring or verifying the distribution of fissionable material in an unopened container. The technique is based on stimulating fissions in nuclear material with 14 MeV neutrons from an associated-particle deuterium-tritium (D-T) generator and counting the subsequent induced fast fission neutrons with an array of fast organic scintillation detectors. For each source neutron incident on the container, the neutron creation time and initial trajectory are known from detection of the associated alpha particle of the d + t → α + n reaction. Many induced fissions will lie along (or near) the interrogating neutron path, allowing an image of the spatial distribution of prompt induced fissions, and thereby fissionable material, to be constructed. A variety of induced-fission imaging measurements have been performed at Oak Ridge National Laboratory with a portable, low-dose D-T generator, including single-view radiographic measurements and three-dimensional tomographic measurements. Results from these measurements will be presented along with the neutron transmission images that have been performed simultaneously. This new capability may have applications to a number of areas in which there may be a need to confirm the presence or configuration of nuclear materials, such as nuclear material control and accountability, quality assurance, treaty confirmation, or homeland security applications.

  10. Imaging plates for nuclear radiations

    International Nuclear Information System (INIS)

    Abe, Ken; Takebe, Masahiro

    1997-01-01

    Full text. The imaging plate (IP, hereafter) is a new opto-electronic X-ray film developed by Fuji Photo Film Co. Ltd., formed with a large area of thin flexible plastic plate coated with photo-estimulable storage phosphor (e.g. Ba F Br: Eu 2+ ). Recently, it has been found highly sensitive to soft X-ray (SR), soft electrons, and also usual alpha, beta, gamma rays and others, e.g. cosmic rays, energy heavy ions, and moreover neutrons through suitable converters inside or outside of the IP. Many types of IP are now used in various fields, such as medical examinations, auto-radiography in vivo/ in situ/ in vitro, X-ray/neutron diffraction/ radiography, electron microscopy. RI contamination, assay of ore. The IP has other striking performances, e.e. extremely low intrinsic noises, a high position resolution, high detection efficiency (100-1000 times) as high as an X-ray film), extremely wide dynamic range of dose (more than 10 5 ). Besides the thermal fading yet left unresolved materially, the only feature lacking and that one has ben longing for is the radiation identification by itself. We found out that the IP has a full potential ability of radiation identification in itself. One evidence found is that the ratio of the twin peaks of the PSL (photo-stimulated luminescence) excitation spectra indicates simply the particle energies, studied and now established. Another is that the photo-beaching provides the fluorescent responses different enough to discriminate the radiations, yet in progress with cyclotron experiments, into the usage of double labeled bio tracers

  11. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  12. Analysis of renal nuclear medicine images

    International Nuclear Information System (INIS)

    Jose, R.M.J.

    2000-01-01

    Nuclear medicine imaging of the renal system involves producing time-sequential images showing the distribution of a radiopharmaceutical in the renal system. Producing numerical and graphical data from nuclear medicine studies requires defining regions of interest (ROIs) around various organs within the field of view, such as the left kidney, right kidney and bladder. Automating this process has several advantages: a saving of a clinician's time; enhanced objectivity and reproducibility. This thesis describes the design, implementation and assessment of an automatic ROI generation system. The performance of the system described in this work is assessed by comparing the results to those obtained using manual techniques. Since nuclear medicine images are inherently noisy, the sequence of images is reconstructed using the first few components of a principal components analysis in order to reduce the noise in the images. An image of the summed reconstructed sequence is then formed. This summed image is segmented by using an edge co-occurrence matrix as a feature space for simultaneously classifying regions and locating boundaries. Two methods for assigning the regions of a segmented image to organ class labels are assessed. The first method is based on using Dempster-Shafer theory to combine uncertain evidence from several sources into a single evidence; the second method makes use of a neural network classifier. The use of each technique in classifying the regions of a segmented image are assessed in separate experiments using 40 real patient-studies. A comparative assessment of the two techniques shows that the neural network produces more accurate region labels for the kidneys. The optimum neural system is determined experimentally. Results indicate that combining temporal and spatial information with a priori clinical knowledge produces reasonable ROIs. Consistency in the neural network assignment of regions is enhanced by taking account of the contextual

  13. The SNM Scanner: A Non-invasive Protocol for Effective Monitoring of Special Nuclear Material Inventories

    International Nuclear Information System (INIS)

    Lanier, R G; Dauffy, L S; Hodge, A M

    2004-01-01

    We suggest a system of monitoring special nuclear material inventories which uses simple mathematical techniques to compare the gross features of emitted gamma-ray spectra. In this report we develop the techniques necessary to make such spectral comparisons and describe their application. We also apply these ideas and develop inventory confirmation results using a room-temperature CdTe detector in a real nuclear-material inventory environment

  14. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  15. Non-invasive diagnosis in cerebral ischemia by means of magnetic resonance imaging and near-infrared spectroscopy

    International Nuclear Information System (INIS)

    Piepgras, A.; Gueckel, F.; Laemmler, B.; Weigel, R.; Schmiedek, P.

    1994-01-01

    We describe the non-invasive assessment of cerebrovascular reserve capacity by means of near-infrared spectroscopy (NIRS) and magnetic resonance imaging. Both methods are compared with transcranial Doppler sonography. There is a good correlation of the three methods in the changes in cerebral oxygen saturation and in blood velocity following acetazolamide stimulation of cerebral blood flow, except found in one patient with unilateral carotid artery occlusion. In this patient we found a decreased cerebrovascular reserve capacity, revealed by a magnetic resonance technique designed to quantify CBV and CBF. We postulate a raised oxygen extraction as raised oxygen extraction as the cause of his changes in oxygen saturation. (orig.) [de

  16. Generation of nuclear magnetic resonance images

    International Nuclear Information System (INIS)

    Beckmann, N.X.

    1986-01-01

    Two generation techniques of nuclear magnetic resonance images, the retro-projection and the direct transformation method are studied these techniques are based on the acquisition of NMR signals which phases and frequency components are codified in space by application of magnetic field gradients. The construction of magnet coils is discussed, in particular a suitable magnet geometry with polar pieces and air gap. The obtention of image contrast by T1 and T2 relaxation times reconstructed from generated signals using sequences such as spin-echo, inversion-recovery and stimulated echo, is discussed. The mathematical formalism of matrix solution for Bloch equations is also presented. (M.C.K.)

  17. High speed imaging system for nuclear diagnostics

    International Nuclear Information System (INIS)

    Eyer, H.H.

    1976-01-01

    A high speed imaging system based on state-of-the-art photosensor arrays has been designed for use in nuclear diagnostics. The system is comprised of a front-end rapid-scan solid-state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in a uphole trailer. The downhole camera takes a ''snapshot'' of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to the LLL computational facility (NADS). The impetus for such a system as well as its operation are discussed. Also discussed are new systems under development which incorporate higher data rates and more resolution

  18. High speed imaging system for nuclear diagnostics

    International Nuclear Information System (INIS)

    Eyer, H.H.

    1976-01-01

    A high speed imaging system based on state-of-the-art photosensor arrays has been designed for use in nuclear diagnostics. The system is comprised of a front-end rapid-scan solid-state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in an uphole trailer. The downhole camera takes a ''snapshot'' of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to the LLL computational facility (NADS). The impetus for such a system as well as its operation is discussed. Also discussed are new systems under development which incorporate higher data rates and more resolution

  19. Nuclear imaging of the skeletal system

    International Nuclear Information System (INIS)

    Yong Whee Bahk

    1992-01-01

    Bone scintigraphy is one of the most valuable nuclear imaging procedure, especially remarkable for its high sensitivity in disclosing bone metastasis of cancer long before radiographic demonstration. Bone scintigraphy is also useful in the diagnosis of covert fracture, occult trauma, bone contusion, early acute osteomyelitis, acute pyogenic arthritis and avascular bone necrosis. Measurements of bone clearance of radiopharmaceuticals, absorptiometry and quantitative bone scintigraphy are applied to the study of metabolic bone disorders such as osteoporosis and osteomalacia

  20. Nuclear magnetic resonance spectroscopy and imaging

    International Nuclear Information System (INIS)

    Jiang Weiping; Wang Qi; Zhou Xin

    2013-01-01

    This paper briefly introduces the basic principle of nuclear magnetic resonance (NMR). Protein's structures and functions and dynamics studied by liquid NMR are elaborated; methods for enhancing the resolution of solid state NMR and its applications are discussed; the principle of magnetic resonance imaging (MRI) is interpreted, and applications in different aspects are reviewed. Finally, the progress of NMR is commented. (authors)

  1. Nuclear imaging of the skeletal system

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee

    1993-12-31

    Bone scintigraphy is one of the most valuable nuclear imaging procedure, especially remarkable for its high sensitivity in disclosing bone metastasis of cancer long before radiographic demonstration. Bone scintigraphy is also useful in the diagnosis of covert fracture, occult trauma, bone contusion, early acute osteomyelitis, acute pyogenic arthritis and avascular bone necrosis. Measurements of bone clearance of radiopharmaceuticals, absorptiometry and quantitative bone scintigraphy are applied to the study of metabolic bone disorders such as osteoporosis and osteomalacia

  2. Images of mycobacterium for nuclear reactions

    International Nuclear Information System (INIS)

    Lima, C.T.S.; Crispim, V.R.; Silva, M.G.

    2007-01-01

    According to the World Health Organization (WHO) tuberculosis is responsible for 2.9 million deaths annually worldwide. The necessity for optimizing time to detect the tuberculosis bacillus (mycobacterium tuberculosis) in the sputum samples of affected individuals (TB patients) led to the development of a methodology based on the doping with boron of the bacillus, submission of the samples to thermal neutron beam and ionizing particles, generating nuclear reactions of the types: 10 B (n,α) 7 Li and 10 B(α, p) 13 C. Images of these bacilli are obtained by means of the nuclear tracks produced in the CR-39 detector for particles products of these nuclear reactions, α and p. When the CR-39 is submitted to a chemical attack the traces are developed and the images of the microorganisms registered in the detector can be observed with a conventional light microscope, characterizing them by morphology. The use of this methodology results in images of the mycobacterium tuberculosis becoming more defined and enlarged than those obtained by bacilloscopy, in which the sample is submitted to the method of coloration of Ziehl-Neelsen (ZN) and observed in light microscopy. (author)

  3. Nuclear imaging in the realm of medical imaging

    International Nuclear Information System (INIS)

    Deconinck, Frank

    2003-01-01

    In medical imaging, information concerning the anatomy or biological processes of a patient is detected and presented on film or screen for interpretation by a reader. The information flow from patient to reader optimally implies: - the emission, transmission or reflection of information carriers, typically photons or sound waves, which have to be correctly modulated by patient information through interactions in the patient; - their detection by adequate imaging equipment preserving essential spectral, spatial and/or temporal information; - the presentation of the information in the most perceivable way; - the observation by an unbiased and trained expert. In reality, only an approximation to this optimal situation is achieved. It is the goal of R and D in the medical imaging field to approach the optimum as much as possible within societal constraints such as patient risk and comfort, economics, etc. First, the basic physical concepts underlying the imaging process will be introduced. Different imaging modalities will then be situated in the realm of medical imaging with some emphasis on nuclear imaging

  4. A Noninvasive Method to Study Regulation of Extracellular Fluid Volume in Rats Using Nuclear Magnetic Resonance

    Science.gov (United States)

    Time-domain nuclear magnetic resonance (TD-NMR)-based measurement of body composition of rodents is an effective method to quickly and repeatedly measure proportions of fat, lean, and fluid without anesthesia. TD-NMR provides a measure of free water in a living animal, termed % f...

  5. Application of mathematical morphology in discrimination nuclear track images

    International Nuclear Information System (INIS)

    Zhang Qingxian; Ge Liangquan; Xiao Caijin

    2008-01-01

    Solid nuclear tracks test is an important and usual method in radioactivity test. But how to divide the overlapped tracks is the key of the processing of digital images of the nuclear tracks. Mathematical Morphology is used in processing of digital images of the nuclear tracks. As a result, the method has been programmed by c++ and used in experiments. It is successful in processing of digital images of the nuclear tracks. (authors)

  6. Nuclear magnetic resonance imaging of the kidney

    International Nuclear Information System (INIS)

    Hricak, H.; Crooks, L.; Sheldon, P.; Kaufman, L.

    1983-01-01

    The role of nuclear magnetic resonance (NMR) imaging of the kidney was analyzed in 18 persons (6 normal volunteers, 3 patients with pelvocaliectasis, 2 with peripelvic cysts, 1 with renal sinus lipomatosis, 3 with renal failure, 1 with glycogen storage disease, and 2 with polycystic kidney disease). Ultrasound and/or computed tomography (CT) studies were available for comparison in every case. In the normal kidney distinct anatomical structures were clearly differentiated by NMR. The best anatomical detail ws obtained with spin echo (SE) imaging, using a pulse sequence interval of 1,000 msec and an echo delay time of 28 msec. However, in the evaluation of normal and pathological conditions, all four intensity images (SE 500/28, SE 500/56, SE 1,000/28, and SE 1,000/56) have to be analyzed. No definite advantage was found in using SE imaging with a pulse sequence interval of 1,500 msec. Inversion recovery imaging enhanced the differences between the cortex and medulla, but it had a low signal-to-noise level and, therefore, a suboptimal overall resolution. The advantages of NMR compared with CT and ultrasound are discussed, and it is concluded that NMR imaging will prove to be a useful modality in the evaluation of renal disease

  7. Filter's importance in nuclear cardiology imaging

    International Nuclear Information System (INIS)

    Jesus, Maria C. de; Lima, Ana L.S.; Santos, Joyra A. dos; Megueriam, Berdj A.

    2008-01-01

    Full text: Nuclear Medicine is a medical speciality which employs tomography procedures for the diagnosis, treatment and prevention of diseases. One of the most commonly used apparatus is the Single Photon Emission Computed Tomography (SPECT). To perform exams, a very small amount of a radiopharmaceutical must be given to the patient. Then, a gamma camera is placed in convenient positions to perform the photon counting, which is used to reconstruct a full 3 dimensional distribution of the radionuclide inside the body or organ. This reconstruction provides a 3-dimensional image in spatial coordinates, of the body or organ under study, allowing the physician to give the diagnostic. Image reconstruction is usually worked in the frequency domain, due to a great simplification introduced by the Fourier decomposition of image spectra. After the reconstruction, an inverse Fourier transform must be applied to trace back the image into spatial coordinates. To optimize this reconstruction procedure, digital filters are used to remove undesirable components of frequency, which can 'shadow' relevant physical signatures of diseases. Unfortunately, the efficiency of the applied filter is strongly dependent on its own mathematical parameters. In this work we demonstrate how filters interfere on image quality in cardiology examinations with SPECT, concerning perfusion and myocardial viability and the importance of the medical physicist in the choice of the right filters avoiding some serious problems that could occur in the inadequate processing of an image damaging the medical diagnosis. (author)

  8. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  9. Non-invasive imaging methods applied to neo- and paleontological cephalopod research

    Science.gov (United States)

    Hoffmann, R.; Schultz, J. A.; Schellhorn, R.; Rybacki, E.; Keupp, H.; Gerden, S. R.; Lemanis, R.; Zachow, S.

    2013-11-01

    Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum-maximum size of objects that can be studied, of the degree of post-processing needed and availability. Main application of the methods is seen in morphometry and volumetry of cephalopod shells in order to improve our understanding of diversity and disparity, functional morphology and biology of extinct and extant cephalopods.

  10. Utility of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) to non-invasively diagnose burn depth in a porcine model☆

    Science.gov (United States)

    Burmeister, David M.; Ponticorvo, Adrien; Yang, Bruce; Becerra, Sandra C.; Choi, Bernard; Durkin, Anthony J.; Christy, Robert J.

    2015-01-01

    Surgical intervention of second degree burns is often delayed because of the difficulty in visual diagnosis, which increases the risk of scarring and infection. Non-invasive metrics have shown promise in accurately assessing burn depth. Here, we examine the use of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) for predicting burn depth. Contact burn wounds of increasing severity were created on the dorsum of a Yorkshire pig, and wounds were imaged with SFDI/LSI starting immediately after-burn and then daily for the next 4 days. In addition, on each day the burn wounds were biopsied for histological analysis of burn depth, defined by collagen coagulation, apoptosis, and adnexal/vascular necrosis. Histological results show that collagen coagulation progressed from day 0 to day 1, and then stabilized. Results of burn wound imaging using non-invasive techniques were able to produce metrics that correlate to different predictors of burn depth. Collagen coagulation and apoptosis correlated with SFDI scattering coefficient parameter ( μs′) and adnexal/vascular necrosis on the day of burn correlated with blood flow determined by LSI. Therefore, incorporation of SFDI scattering coefficient and blood flow determined by LSI may provide an algorithm for accurate assessment of the severity of burn wounds in real time. PMID:26138371

  11. Helping Your Heart with Nuclear Imaging

    International Nuclear Information System (INIS)

    Madsen, Michael Amdi

    2014-01-01

    The IAEA is helping in the fight against cardiovascular diseases (CVDs) by assisting its Member States in using nuclear science and technology to track and monitor CVDs. Nuclear imaging techniques allow doctors to look inside a patient’s body and see how organs function without running the risk of surgery. CVDs kill more people than just about anything else on the planet. The World Health Organization (WHO) estimates that roughly 30 per cent of all deaths in 2008 were caused by CVDs. That number is increasing, and by 2030 the WHO estimates that more than 23 million people will die annually from CVDs. For comparison, that is equivalent to roughly the entire population of a medium-sized country

  12. Muon trackers for imaging a nuclear reactor

    Science.gov (United States)

    Kume, N.; Miyadera, H.; Morris, C. L.; Bacon, J.; Borozdin, K. N.; Durham, J. M.; Fuzita, K.; Guardincerri, E.; Izumi, M.; Nakayama, K.; Saltus, M.; Sugita, T.; Takakura, K.; Yoshioka, K.

    2016-09-01

    A detector system for assessing damage to the cores of the Fukushima Daiichi nuclear reactors by using cosmic-ray muon tomography was developed. The system consists of a pair of drift-tube tracking detectors of 7.2× 7.2-m2 area. Each muon tracker consists of 6 x-layer and 6 y-layer drift-tube detectors. Each tracker is capable of measuring muon tracks with 12 mrad angular resolutions, and is capable of operating under 50-μ Sv/h radiation environment by removing gamma induced background with a novel time-coincidence logic. An estimated resolution to observe nuclear fuel debris at Fukushima Daiichi is 0.3 m when the core is imaged from outside the reactor building.

  13. Near-infrared quantum-dot-based non-invasive in vivo imaging of squamous cell carcinoma U14

    International Nuclear Information System (INIS)

    Cao Yu'an; Yang Kai; Li Zhigang; Zhao Cheng; Yang Jia; Shi Chunmeng

    2010-01-01

    Near-infrared (near-ir) quantum dots (QDs) are well known for their excellent optical characteristics. They hold great potential for applications in non-invasive long term observation and tracing of cells in vivo. Here, near-ir QDs with an emission wavelength of 800 nm (QD800) were used to label squamous cell carcinoma cell line U14 (U14/QD800). The effect of tissue depth and animal fur on the imaging sensitivity and stability was evaluated following subcutaneous and intramuscular injection into Kunming mice, employing an in vivo imaging system. We have demonstrated that QD800-based visual in vivo imaging increased the sensitivity of cancer early detection by a factor of 100 compared with traditional detection methods. More importantly, this study proved for the first time that animal fur has a serious impact on the detection sensitivity and duration of QD-based in vivo imaging. In general, the duration and sensitivity of QD800 for in vivo imaging were not greatly affected by a depth less than 1.8 ± 0.21 mm (subcutaneous or intramuscular). This study provides critical reference data for further research on near-ir QD-based early detection and in vivo visual observation of cancer.

  14. A simple and non-invasive method for nuclear transformation of intact-walled Chlamydomonas reinhardtii.

    Directory of Open Access Journals (Sweden)

    Sora Kim

    Full Text Available Genetic engineering in microalgae is gaining attraction but nuclear transformation methods available so far are either inefficient or require special equipment. In this study, we employ positively charged nanoparticles, 3-aminopropyl-functionalized magnesium phyllosilicate (aminoclay, approximate unit cell composition of [H2N(CH23]8Si8Mg6O12(OH4, for nuclear transformation into eukaryotic microalgae. TEM and EDX analysis of the process of transformation reveals that aminoclay coats negatively-charged DNA biomolecules and forms a self-assembled hybrid nanostructure. Subsequently, when this nanostructure is mixed with microalgal cells and plated onto selective agar plates with high friction force, cell wall is disrupted facilitating delivery of plasmid DNA into the cell and ultimately to the nucleus. This method is not only simple, inexpensive, and non-toxic to cells but also provides efficient transformation (5.03×10(2 transformants/µg DNA, second only to electroporation which needs advanced instrumentation. We present optimized parameters for efficient transformation including pre-treatment, friction force, concentration of foreign DNA/aminoclay, and plasticity of agar plates. It is also confirmed the successful integration and stable expression of foreign gene in Chlamydomonas reinhardtii through molecular methods.

  15. Noninvasive enhanced mid-IR imaging of breast cancer development in vivo

    Science.gov (United States)

    Case, Jason R.; Young, Madison A.; Dréau, D.; Trammell, Susan R.

    2015-11-01

    Lumpectomy coupled with radiation therapy and/or chemotherapy is commonly used to treat breast cancer patients. We are developing an enhanced thermal IR imaging technique that has the potential to provide real-time imaging to guide tissue excision during a lumpectomy by delineating tumor margins. This enhanced thermal imaging method is a combination of IR imaging (8 to 10 μm) and selective heating of blood (˜0.5°C) relative to surrounding water-rich tissue using LED sources at low powers. Postacquisition processing of these images highlights temporal changes in temperature and the presence of vascular structures. In this study, fluorescent, standard thermal, and enhanced thermal imaging modalities, as well as physical caliper measurements, were used to monitor breast cancer tumor volumes over a 30-day study period in 19 mice implanted with 4T1-RFP tumor cells. Tumor volumes calculated from fluorescent imaging follow an exponential growth curve for the first 22 days of the study. Cell necrosis affected the tumor volume estimates based on the fluorescent images after day 22. The tumor volumes estimated from enhanced thermal imaging, standard thermal imaging, and caliper measurements all show exponential growth over the entire study period. A strong correlation was found between tumor volumes estimated using fluorescent imaging, standard IR imaging, and caliper measurements with enhanced thermal imaging, indicating that enhanced thermal imaging monitors tumor growth. Further, the enhanced IR images reveal a corona of bright emission along the edges of the tumor masses associated with the tumor margin. In the future, this IR technique might be used to estimate tumor margins in real time during surgical procedures.

  16. Free Radical Imaging Using In Vivo Dynamic Nuclear Polarization-MRI.

    Science.gov (United States)

    Utsumi, Hideo; Hyodo, Fuminori

    2015-01-01

    Redox reactions that generate free radical intermediates are essential to metabolic processes, and their intermediates can produce reactive oxygen species, which may promote diseases related to oxidative stress. The development of an in vivo electron spin resonance (ESR) spectrometer and its imaging enables us noninvasive and direct measurement of in vivo free radical reactions in living organisms. The dynamic nuclear polarization magnetic resonance imaging (DNP-MRI), also called PEDRI or OMRI, is also a new imaging method for observing free radical species in vivo. The spatiotemporal resolution of free radical imaging with DNP-MRI is comparable with that in MRI, and each of the radical species can be distinguished in the spectroscopic images by changing the frequency or magnetic field of ESR irradiation. Several kinds of stable nitroxyl radicals were used as spin probes to detect in vivo redox reactions. The signal decay of nitroxyl probes, which is determined with in vivo DNP-MRI, reflects the redox status under oxidative stress, and the signal decay is suppressed by prior administration of antioxidants. In addition, DNP-MRI can also visualize various intermediate free radicals from the intrinsic redox molecules. This noninvasive method, in vivo DNP-MRI, could become a useful tool for investigating the mechanism of oxidative injuries in animal disease models and the in vivo effects of antioxidant drugs. © 2015 Elsevier Inc. All rights reserved.

  17. Non-invasive imaging methods applied to neo- and paleo-ontological cephalopod research

    Science.gov (United States)

    Hoffmann, R.; Schultz, J. A.; Schellhorn, R.; Rybacki, E.; Keupp, H.; Gerden, S. R.; Lemanis, R.; Zachow, S.

    2014-05-01

    Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum/maximum size of objects that can be studied, the degree of post-processing needed and availability. The main application of the methods is seen in morphometry and volumetry of cephalopod shells. In particular we present a method for precise buoyancy calculation. Therefore, cephalopod shells were scanned together with different reference bodies, an approach developed in medical sciences. It is necessary to know the volume of the reference bodies, which should have similar absorption properties like the object of interest. Exact volumes can be obtained from surface scanning. Depending on the dimensions of the study object different computed tomography techniques were applied.

  18. Non-invasive measurement and imaging of tissue iron oxide nanoparticle concentrations in vivo using proton relaxometry

    International Nuclear Information System (INIS)

    St Pierre, T G; Clark, P R; Chua-anusorn, W; Fleming, A; Pardoe, H; Jeffrey, G P; Olynyk, J K; Pootrakul, P; Jones, S; Moroz, P

    2005-01-01

    Magnetic nanoparticles and microparticles can be found in biological tissues for a variety of reasons including pathological deposition of biogenic particles, administration of synthetic particles for scientific or clinical reasons, and the inclusion of biogenic magnetic particles for the sensing of the geomagnetic field. In applied magnetic fields, the magnetisation of tissue protons can be manipulated with radiofrequency radiation such that the macroscopic magnetisation of the protons precesses freely in the plane perpendicular to the applied static field. The presence of magnetic particles within tissue enhances the rate of dephasing of proton precession with higher concentrations of particles resulting in higher dephasing rates. Magnetic resonance imaging instruments can be used to measure and image the rate of decay of spin echo recoverable proton transverse magnetisation (R 2 ) within tissues enabling the measurement and imaging of magnetic particle concentrations with the aid of suitable calibration curves. Applications include the non-invasive measurement of liver iron concentrations in iron-overload disorders and measurement and imaging of magnetic particle concentrations used in magnetic hyperthermia therapy. Future applications may include the tracking of magnetically labelled drugs or biomolecules and the measurement of fibrotic liver damage

  19. Non-Invasive Assessment of Hepatic Fibrosis by Elastic Measurement of Liver Using Magnetic Resonance Tagging Images

    Directory of Open Access Journals (Sweden)

    Xuejun Zhang

    2018-03-01

    Full Text Available To date, the measurement of the stiffness of liver requires a special vibrational tool that limits its application in many hospitals. In this study, we developed a novel method for automatically assessing the elasticity of the liver without any use of contrast agents or mechanical devices. By calculating the non-rigid deformation of the liver from magnetic resonance (MR tagging images, the stiffness was quantified as the displacement of grids on the liver image during a forced exhalation cycle. Our methods include two major processes: (1 quantification of the non-rigid deformation as the bending energy (BE based on the thin-plate spline method in the spatial domain and (2 calculation of the difference in the power spectrum from the tagging images, by using fast Fourier transform in the frequency domain. By considering 34 cases (17 normal and 17 abnormal liver cases, a remarkable difference between the two groups was found by both methods. The elasticity of the liver was finally analyzed by combining the bending energy and power spectral features obtained through MR tagging images. The result showed that only one abnormal case was misclassified in our dataset, which implied our method for non-invasive assessment of liver fibrosis has the potential to reduce the traditional liver biopsy.

  20. Non-invasive imaging and monitoring of rodent retina using simultaneous dual-band optical coherence tomography

    Science.gov (United States)

    Cimalla, Peter; Burkhardt, Anke; Walther, Julia; Hoefer, Aline; Wittig, Dierk; Funk, Richard; Koch, Edmund

    2011-03-01

    Spectral domain dual-band optical coherence tomography for simultaneous imaging of rodent retina in the 0.8 μm and 1.3 μm wavelength region and non-invasive monitoring of the posterior eye microstructure in the field of retinal degeneration research is demonstrated. The system is illuminated by a supercontinuum laser source and allows three-dimensional imaging with high axial resolution better than 3.8 μm and 5.3 μm in tissue at 800 nm and 1250 nm, respectively, for precise retinal thickness measurements. A fan-shaped scanning pattern with the pivot point close to the eye's pupil and a contact lens are applied to obtain optical access to the eye's fundus. First in vivo experiments in a RCS (royal college of surgeons) rat model with gene-related degeneration of the photoreceptor cells show good visibility of the retinal microstructure with sufficient contrast for thickness measurement of individual retinal layers. An enhanced penetration depth at 1250 nm is clearly identifiable revealing sub-choroidal structures that are not visible at 800 nm. Furthermore, additional simultaneous imaging at 1250 nm improves image quality by frequency compounding speckle noise reduction. These results are encouraging for time course studies of the rodent retina concerning its development related to disease progression and treatment response.

  1. Eigenimage filtering of nuclear medicine image sequences

    International Nuclear Information System (INIS)

    Windham, J.P.; Froelich, J.W.; Abd-Allah, M.

    1985-01-01

    In many nuclear medicine imaging sequences the localization of radioactivity in organs other than the target organ interferes with imaging of the desired anatomical structure or physiological process. A filtering technique has been developed which suppresses the interfering process while enhancing the desired process. This technique requires the identification of temporal sequential signatures for both the interfering and desired processes. These signatures are placed in the form of signature vectors. Signature matrices, M/sub D/ and M/sub U/, are formed by taking the outer product expansion of the temporal signature vectors for the desired and interfering processes respectively. By using the transformation from the simultaneous diagonalization of these two signature matrices a weighting vector is obtained. The technique is shown to maximize the projection of the desired process while minimizing the interfering process based upon an extension of Rayleigh's Principle. The technique is demonstrated for first pass renal and cardiac flow studies. This filter offers a potential for simplifying and extending the accuracy of diagnostic nuclear medicine procedures

  2. Non-invasive diagnosis of isolated chylopericardium using precordial pericardial imaging after oral administration of 131I-triolein

    International Nuclear Information System (INIS)

    Fujiseki, Yoshiki; Katsura, Tadahiko; Goto, Masakatsu; Kawanishi, Katsuyuki

    1982-01-01

    Chylopericardium is a rare disease and affects both sexes equally from neonate to adult. Usually, there are abnormal connections between the pericardial cavity and thoracic lymphatic systems. These connections are detected by (1) recovery of orally administered Sudan III from pericardial fluid, (2) evidence of radioactivity in the pericardial fluid by paracentesis after oral administration of 131 I-labeled triolein, and (3) lymphangiography. However, these method are technically difficult and invasive, thus sometimes dangerous for children. We employed precordial pericardial imaging after oral administration of 131 I-labeled triolein on a 9-year-old Japanese girl wth isolated chylopericardium before and after surgery. Abnormal connections and the back-ward flow to the pulmonary lymphatics were demonstrated by this method. This is an easy, non-invasive, reliable and safe method for detecting the abnormal connections of pericardial and lymphatic systems in children with chylopericardium. (author)

  3. Asynchrony of the early maturation of white matter bundles in healthy infants: Quantitative landmarks revealed noninvasively by diffusion tensor imaging

    International Nuclear Information System (INIS)

    Dubois, J.; Perrin, M.; Mangin, J.F.; Cointepas, Y.; Duchesnay, E.; Le Bihan, D.; Hertz-Pannier, L.; Dehaene-Lambertz, G.; Dubois, J.; Dehaene-Lambertz, G.; Perrin, M.; Mangin, J.F.; Cointepas, Y.; Duchesnay, E.; Le Bihan, D.; Hertz-Pannier, L.

    2008-01-01

    Normal cognitive development in infants follows a well-known temporal sequence, which is assumed to be correlated with the structural maturation of underlying functional networks. Postmortem studies and, more recently, structural MR imaging studies have described qualitatively the heterogeneous spatio-temporal progression of white matter myelination. However, in vivo quantification of the maturation phases of fiber bundles is still lacking. We used noninvasive diffusion tensor MR imaging and tractography in twenty-three 1-4-month-old healthy infants to quantify the early maturation of the main cerebral fascicles. A specific maturation model, based on the respective roles of different maturational processes on the diffusion phenomena, was designed to highlight asynchronous maturation across bundles by evaluating the time-course of mean diffusivity and anisotropy changes over the considered developmental period. Using an original approach, a progression of maturation in four relative stages was determined in each tract by estimating the maturation state and speed, from the diffusion indices over the infants group compared with an adults group on one hand, and in each tract compared with the average over bundles on the other hand. Results were coherent with, and extended previous findings in 8 of 11 bundles, showing the anterior limb of the internal capsule and cingulum as the most immature, followed by the optic radiations, arcuate and inferior longitudinal fascicles, then the spino-thalamic tract and fornix, and finally the cortico-spinal tract as the most mature bundle. Thus, this approach provides new quantitative landmarks for further noninvasive research on brain-behavior relationships during normal and abnormal development. (authors)

  4. Nuclear imaging evaluation of galactosylation of chitosan

    International Nuclear Information System (INIS)

    Jeong, Hwan Jeong; Kim, Eun Mi; Kim, Chang Guhn; Park, In Kyu; Cho, Chong Su; Bom, Hee Seung

    2004-01-01

    Chitosan has been studied as a non-viral gene delivery vector, drug delivery carrier, metal chelater, food additive, and radiopharmaceutical, among other things. Recently, galactose-graft chitosan was studied as a non-viral gene and drug delivery vector to target hepatocytes. The aim of this study was to investigate the usefulness of nuclear imaging for in vivo evaluation of targeting the hepatocyte by galactose grafting. Galactosyl methylated chitosan (GMC) was produced by methylation to lactobionic acid coupled chitosan Cytotoxicity of 99 mTc-GMC was determined by MTT assay. Rabbits were injected via their auricular vein with 99 mTc-GMC and 99 mTc-methylated chitosan (MC), the latter of which does not contain a galactose group, and images were acquired with a gamma camera equipped with a parallel hole collimator. The composition of the galactose group in galactosylated chitosan (GC), as well as the tri-, di-, or mono-methylation of GMC, was confirmed by NMR spectroscopy. The results of MTT assay indicated that 99 mTc-GMC was non-toxic. 99 mTc-GMC specifically accumulated in the liver within 10 minutes of injection and maintained high hepatic uptake. In contrast, 99 mTc-MC showed faint liver uptake. 99 mTc-GMC scintigraphy of rabbits showed that the galactose ligand principally targeted the liver while the chitosan functionalities led to excretion through the urinary system. Bioconjugation with a specific ligand endows some degree of targetability to an administered molecule or drug, as in the case of galactose for hepatocyte in vivo, and evaluating said targetability is a clear example of the great benefit proffered by nuclear imaging

  5. Molecular Imaging and nuclear medicine: expectations and requirements

    International Nuclear Information System (INIS)

    Rollo, F.D.

    2003-01-01

    Molecular Imaging with Nuclear Medicine offers earlier, more accurate and more specific diagnosis, as well as targeted molecular therapy, providing significant improvements in clinical outcomes. (orig.)

  6. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T

    Energy Technology Data Exchange (ETDEWEB)

    Kjoerstad, Aasmund; Corteville, Dominique M.R.; Zoellner, Frank G.; Schad, Lothar R. [Heidelberg Univ., Medical Faculty Mannheim (Germany). Computer Assisted Clinical Medicine; Henzler, Thomas [Heidelberg Univ., Medical Faculty Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine; Schmid-Bindert, Gerald [Heidelberg Univ., Medical Faculty Mannheim (Germany). Interdisciplinary Thoracic Oncology

    2015-07-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15±0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93±0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61±1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Conclusion Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue.

  7. Wavelength-Modulated Differential Photoacoustic (WM-DPA) imaging: a high dynamic range modality towards noninvasive diagnosis of cancer

    Science.gov (United States)

    Dovlo, Edem; Lashkari, Bahman; Choi, Sung soo Sean; Mandelis, Andreas

    2016-03-01

    This study explores wavelength-modulated differential photo-acoustic (WM-DPA) imaging for non-invasive early cancer detection via sensitive characterization of functional information such as hemoglobin oxygenation (sO2) levels. Well-known benchmarks of tumor formation such as angiogenesis and hypoxia can be addressed this way. While most conventional photo-acoustic imaging has almost entirely employed high-power pulsed lasers, frequency-domain photo-acoustic radar (FD-PAR) has seen significant development as an alternative technique. It employs a continuous wave laser source intensity-modulated and driven by frequency-swept waveforms. WM-DPA imaging utilizes chirp modulated laser beams at two distinct wavelengths for which absorption differences between oxy- and deoxygenated hemoglobin are minimum (isosbestic point, 805 nm) and maximum (680 nm) to simultaneously generate two signals detected using a standard commercial array transducer as well as a single-element transducer that scans the sample. Signal processing is performed using Lab View and Matlab software developed in-house. Minute changes in total hemoglobin concentration (tHb) and oxygenation levels are detectable using this method since background absorption is suppressed due to the out-of-phase modulation of the laser sources while the difference between the two signals is amplified, thus allowing pre-malignant tumors to become identifiable. By regulating the signal amplitude ratio and phase shift the system can be tuned to applications like cancer screening, sO2 quantification and hypoxia monitoring in stroke patients. Experimental results presented demonstrate WM-DPA imaging of sheep blood phantoms in comparison to single-wavelength FD-PAR imaging. Future work includes the functional PA imaging of small animals in vivo.

  8. Non-Invasive and Minimally Invasive Imaging Evaluation of CSF Rhinorrhoea – a Retrospective Study with Review of Literature

    International Nuclear Information System (INIS)

    Vimala, Leena Robinson; Jasper, Anitha; Irodi, Aparna

    2016-01-01

    Localization of a cerebrospinal fluid [CSF] fistula is a diagnostic challenge. The choice of an optimal imaging technique is necessary to locate the site of CSF leak which is required for surgical/endoscopic repair of the CSF fistula. Retrospective analysis of imaging was performed in 33 patients who presented with symptoms suggestive of CSF rhinorrhoea over a period of two years. Either a bone defect on high resolution CT [HRCT] or CSF column extending extracranially from the subarachnoid space with or without brain/ meningeal herniation on magnetic resonance [MR] cisternography was considered positive for CSF leak. The MR imaging technique included 1-mm heavily T2-weighted [TR 2000 ms; TE-200 ms] fast spin echo study in coronal and sagittal planes. HRCT sections involved 0.625 to 0.8-mm sections in the coronal plane, with or without axial planes, through the paranasal sinuses, reconstructed in a sharp algorithm and acquired with the patient in prone position. Imaging findings were compared with endoscopic findings, being the gold standard for the assessment of CSF rhinorrhea. A total of 25 patients had a combination of HRCT and MR cisternography. The sensitivity, specificity, positive predictive value [PPV] and negative predictive value [NPV] of both MR cisternography and HRCT together were 93%, 100%, 100% and 50% respectively. Two patients underwent only MR cisternography, 5 patients underwent only HRCT and one patient underwent HRCT, MR cisternography and CT cisternography. Though PPV was 100% in the groups with HRCT alone, MR cisternography alone and combined CT cisternography, HRCT and MR cisternography, the results were not statistically significant as the number of patients in those groups was lower. Combination of MR cisternography and HRCT appears to be complementary, accurate and non-invasive and should be considered as optimal imaging modality for pre-op imaging in the evaluation of CSF rhinorrhoea

  9. Non-invasive quantitative pulmonary V/Q imaging using Fourier decomposition MRI at 1.5T.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2015-12-01

    Techniques for quantitative pulmonary perfusion and ventilation using the Fourier Decomposition method were recently demonstrated. We combine these two techniques and show that ventilation-perfusion (V/Q) imaging is possible using only a single MR acquisition of less than thirty seconds. The Fourier Decomposition method is used in combination with two quantification techniques, which extract baselines from within the images themselves and thus allows quantification. For the perfusion, a region assumed to consist of 100% blood is utilized, while for the ventilation the zero-frequency component is used. V/Q-imaging is then done by dividing the quantified ventilation map with the quantified perfusion map. The techniques were used on ten healthy volunteers and fifteen patients diagnosed with lung cancer. A mean V/Q-ratio of 1.15 ± 0.22 was found for the healthy volunteers and a mean V/Q-ratio of 1.93 ± 0.83 for the non-afflicted lung in the patients. Mean V/Q-ratio in the afflicted (tumor-bearing) lung was found to be 1.61 ± 1.06. Functional defects were clearly visible in many of the patient images, but 5 of 15 patient images had to be excluded due to artifacts or low SNR, indicating a lack of robustness. Non-invasive, quantitative V/Q-imaging is possible using Fourier Decomposition MRI. The method requires only a single acquisition of less than 30 seconds, but robustness in patients remains an issue. Copyright © 2015. Published by Elsevier GmbH.

  10. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    International Nuclear Information System (INIS)

    Borelli, Flavio Antonio de Oliveira; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R.

    2013-01-01

    Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m 2 . Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction

  11. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Borelli, Flavio Antonio de Oliveira, E-mail: fborelli@cardiol.br; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R. [Instituto Dante Pazzanese de Cardiologia, São Paulo, SP (Brazil)

    2013-11-15

    Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m{sup 2}. Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction.

  12. Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope

    Science.gov (United States)

    Dubra, Alfredo; Sulai, Yusufu; Norris, Jennifer L.; Cooper, Robert F.; Dubis, Adam M.; Williams, David R.; Carroll, Joseph

    2011-01-01

    The rod photoreceptors are implicated in a number of devastating retinal diseases. However, routine imaging of these cells has remained elusive, even with the advent of adaptive optics imaging. Here, we present the first in vivo images of the contiguous rod photoreceptor mosaic in nine healthy human subjects. The images were collected with three different confocal adaptive optics scanning ophthalmoscopes at two different institutions, using 680 and 775 nm superluminescent diodes for illumination. Estimates of photoreceptor density and rod:cone ratios in the 5°–15° retinal eccentricity range are consistent with histological findings, confirming our ability to resolve the rod mosaic by averaging multiple registered images, without the need for additional image processing. In one subject, we were able to identify the emergence of the first rods at approximately 190 μm from the foveal center, in agreement with previous histological studies. The rod and cone photoreceptor mosaics appear in focus at different retinal depths, with the rod mosaic best focus (i.e., brightest and sharpest) being at least 10 μm shallower than the cones at retinal eccentricities larger than 8°. This study represents an important step in bringing high-resolution imaging to bear on the study of rod disorders. PMID:21750765

  13. Image-assisted non-invasive and dynamic biomechanical analysis of human joints

    International Nuclear Information System (INIS)

    Muhit, Abdullah A; Pickering, Mark R; Scarvell, Jennifer M; Ward, Tom; Smith, Paul N

    2013-01-01

    Kinematic analysis provides a strong link between musculoskeletal injuries, chronic joint conditions, treatment planning/monitoring and prosthesis design/outcome. However, fast and accurate 3D kinematic analysis still remains a challenge in order to translate this procedure into clinical scenarios. 3D computed tomography (CT) to 2D single-plane fluoroscopy registration is a promising non-invasive technology for biomechanical examination of human joints. Although this technique has proven to be very precise in terms of in-plane translation and rotation measurements, out-of-plane motion estimations have been a difficulty so far. Therefore, to enable this technology into clinical translation, precise and fast estimation of both in-plane and out-of-plane movements is crucial, which is the aim of this paper. Here, a fast and accurate 3D/2D registration technique is proposed to evaluate biomechanical/kinematic analysis. The proposed algorithm utilizes a new multi-modal similarity measure called ‘sum of conditional variances’, a coarse-to-fine Laplacian of Gaussian filtering approach for robust gradient-descent optimization and a novel technique for the analytic calculation of the required gradients for out-of-plane rotations. Computer simulations and in vitro experiments showed that the new approach was robust in terms of the capture range, required significantly less iterations to converge and achieved good registration and kinematic accuracy when compared to existing techniques and to the ‘gold-standard’ Roentgen stereo analysis. (paper)

  14. Non-invasive methods for estimating mPAP in COPD using cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Johns, C.S.; Capener, D.A.; Oram, C.; Wild, J.M.; Rajaram, S.; Elliot, C.; Condliffe, R.; Kiely, D.G.; Swift, A.J.

    2018-01-01

    Pulmonary hypertension (PH) is associated with a poor outcome in chronic obstructive pulmonary disease (COPD) and is diagnosed invasively. We aimed to assess the diagnostic accuracy and prognostic value of non-invasive cardiovascular magnetic resonance (CMR) models. Patients with COPD and suspected PH, who underwent CMR and right heart catheter (RHC) were identified. Three candidate models were assessed: 1, CMR-RV model, based on right ventricular (RV) mass and interventricular septal angle; 2, CMR PA/RV includes RV mass, septal angle and pulmonary artery (PA) measurements; 3, the Alpha index, based on RV ejection fraction and PA size. Of 102 COPD patients, 87 had PH. The CMR-PA/RV model had the strongest diagnostic accuracy (sensitivity 92%, specificity 80%, positive predictive value 96% and negative predictive value 63%, AUC 0.93, p<0.0001). Splitting RHC-mPAP, CMR-RV and CMR-PA/RV models by 35mmHg gave a significant difference in survival, with log-rank chi-squared 5.03, 5.47 and 7.10. RV mass and PA relative area change were the independent predictors of mortality at multivariate Cox regression (p=0.002 and 0.030). CMR provides diagnostic and prognostic information in PH-COPD. The CMR-PA/RV model is useful for diagnosis, the RV mass index and PA relative area change are useful to assess prognosis. (orig.)

  15. Non-invasive in-vivo imaging of stem cells after transplantation in cardiovascular tissue

    DEFF Research Database (Denmark)

    Mathiasen, Anders Bruun; Kastrup, Jens

    2013-01-01

    Stem cell therapy for degenerative diseases, including ischemic heart disease is now a clinical reality. In the search for the optimal cell type for each patient category, many different stem cell subpopulations have been used. In addition, different cell processing procedures and delivery methods......, migration and efficacy of the transplanted cells. Great effort is being made in finding new and better imaging techniques for different imaging modalities, and much have already been learned. But there are still many unanswered questions. In this review, we give an overview of the imaging modalities used...

  16. Quantitative, Noninvasive Imaging of DNA Damage in Vivo of Prostate Cancer Therapy by Transurethral Photoacoustic (TUPA) Imaging

    Science.gov (United States)

    2014-10-01

    fluorescence computed tomography (XFCT) imaging with an optimized spectro -spatial detector configuration: theory and simulation, IEEE Trans. Med. Imag., 99...with ultraviolet ( UV ) illumination, and wa- ter [13] and lipid [14] with near-infrared illumination. In fact, PAM can potentially image any molecule

  17. Invasive or non-invasive imaging for detecting high-risk coronary lesions?

    NARCIS (Netherlands)

    K. Patel (Kush); J. Tarkin (Jason); P.W.J.C. Serruys (Patrick); E. Tenekecioglu (Erhan); N. Foin (Nicolas); Y. Zhang (Yaojun); T. Crake (Tom); J. Moon (James); A. Mathur (Anthony); C.V. Bourantas (Christos)

    2017-01-01

    markdownabstract_Introduction:_ Advances in our understanding about atherosclerotic evolution have enabled us to identify specific plaque characteristics that are associated with coronary plaque vulnerability and cardiovascular events. With constant improvements in signal and image processing an

  18. MRI-Derived Cellularity Index as a Potential Noninvasive Imaging Biomarker of Prostate Cancer

    Science.gov (United States)

    2016-12-01

    patients has revealed atypical gelatinous necrosis. We have coined this abnormality bevacizumab-related imaging abnormality (BRIA) and have observed that...neurologic disorders . Radiology 1986;161: 401–7. 25. Merboldt K-D, HanickeW, Frahm J. Self-diffusion NMR imaging using stimulated echoes. J Magn Reson...sensitivity and functional characterization 8 Left peripheral mid gland 3–5 o’clock Bulges the capsule, no gross extraprostatic extension Motion and

  19. [Applicability of non-invasive imaging methods in forensic medicine and forensic anthropology in particular].

    Science.gov (United States)

    Marcinková, Mária; Straka, Ľubomír; Novomeský, František; Janík, Martin; Štuller, František; Krajčovič, Jozef

    2018-01-01

    Massive progress in developing even more precise imaging modalities influenced all medical branches including the forensic medicine. In forensic anthropology, an inevitable part of forensic medicine itself, the use of all imaging modalities becomes even more important. Despite of acquiring more accurate informations about the deceased, all of them can be used in the process of identification and/or age estimation. X - ray imaging is most commonly used in detecting foreign bodies or various pathological changes of the deceased. Computed tomography, on the other hand, can be very helpful in the process of identification, whereas outcomes of this examination can be used for virtual reconstruction of living objects. Magnetic resonance imaging offers new opportunities in detecting cardiovascular pathological processes or develompental anomalies. Ultrasonography provides promising results in age estimation of living subjects without excessive doses of radiation. Processing the latest information sources available, authors introduce the application examples of X - ray imaging, computed tomography, magnetic resonance imaging and ultrasonography in everyday forensic medicine routine, with particular focusing on forensic anthropology.

  20. Detection of Melanoma Metastases in Resected Human Lymph Nodes by Noninvasive Multispectral Photoacoustic Imaging

    Directory of Open Access Journals (Sweden)

    Gerrit Cornelis Langhout

    2014-01-01

    Full Text Available Objective. Sentinel node biopsy in patients with cutaneous melanoma improves staging, provides prognostic information, and leads to an increased survival in node-positive patients. However, frozen section analysis of the sentinel node is not reliable and definitive histopathology evaluation requires days, preventing intraoperative decision-making and immediate therapy. Photoacoustic imaging can evaluate intact lymph nodes, but specificity can be hampered by other absorbers such as hemoglobin. Near infrared multispectral photoacoustic imaging is a new approach that has the potential to selectively detect melanin. The purpose of the present study is to examine the potential of multispectral photoacoustic imaging to identify melanoma metastasis in human lymph nodes. Methods. Three metastatic and nine benign lymph nodes from eight melanoma patients were scanned ex vivo using a Vevo LAZR© multispectral photoacoustic imager and were spectrally analyzed per pixel. The results were compared to histopathology as gold standard. Results. The nodal volume could be scanned within 20 minutes. An unmixing procedure was proposed to identify melanoma metastases with multispectral photoacoustic imaging. Ultrasound overlay enabled anatomical correlation. The penetration depth of the photoacoustic signal was up to 2 cm. Conclusion. Multispectral three-dimensional photoacoustic imaging allowed for selective identification of melanoma metastases in human lymph nodes.

  1. Non-invasive Florentine Renaissance Panel Painting Replica Structures Investigation by Using Terahertz Time-Domain Imaging (THz-TDI) Technique

    DEFF Research Database (Denmark)

    Dandolo, Corinna Ludovica Koch; Picollo, Marcello; Cucci, Costanza

    2016-01-01

    The potentials of the Terahertz Time-Domain Imaging (THz-TDI) technique for a non-invasive inspection of panel paintings have been considered in detail. The THz-TD data acquired on a replica of a panel painting made in imitation of Italian Renaissance panel paintings were processed in order to pr...

  2. Cellular dosimetry in nuclear medicine imaging: training

    International Nuclear Information System (INIS)

    Gardin, I.; Faraggi, M.; Stievenart, J.L.; Le Guludec, D.; Bok, B.

    1998-01-01

    The radionuclides used in nuclear medicine imaging emit not only diagnostically useful photons, but also energy electron emissions, responsible for dose heterogeneity at the cellular level. The mean dose delivered to the cell nucleus by electron emissions of 99m Tc, 123 I, 111 In, 67 Ga, and 201 Tl, has been calculated, for the cell nucleus, a cytoplasmic and a cell membrane distribution of radioactivity. This model takes into account both the self-dose which results from the radionuclide located in the target cell, and the cross-dose, which comes from the surrounding cells. The results obtained by cellular dosimetry (D cel ) have been compared with those obtained with conventional dosimetry (D conv ), by assuming the same amount of radioactivity per cell. Cellular dosimetry shows, for a cytoplasmic and a cell membrane distributions of radioactivity, that the main contribution to the dose to the cell nucleus, comes from the surrounding cells. On the other hand, for a cell nucleus distribution of radioactivity, the self-dose is not negligible and may be the main contribution. The comparison between cellular and conventional dosimetry shows that D cel /D conv ratio ranges from 0.61 and O.89, in case of a cytoplasmic and a cell membrane distributions of radioactivity, depending on the radionuclide and cell dimensions. Thus, conventional dosimetry slightly overestimates the mean dose to the cell nucleus. On the other hand, D cel /D conv ranges from 1.1 to 75, in case of a cell nucleus distribution of radioactivity. Conventional dosimetry may strongly underestimates the absorbed dose to the nucleus, when radioactivity is located in the nucleus. The study indicates that in nuclear medicine imaging, cellular dosimetry may lead to a better understanding of biological effects of radiopharmaceuticals. (authors)

  3. Nuclear medicine imaging of bone infections

    International Nuclear Information System (INIS)

    Love, C.; Palestro, C.J.

    2016-01-01

    Osteomyelitis is a broad group of infectious diseases that involve the bone and/or bone marrow. It can arise haematogenously, via extension from a contiguous infection, or by direct inoculation during surgery or trauma. The diagnosis is not always obvious and imaging tests are frequently performed as part of the diagnostic work-up. Commonly performed radionuclide tests include technetium-99m ("9"9"mTc)-diphosphonate bone scintigraphy (bone), and gallium-67 ("6"7Ga) and in vitro labelled leukocyte (white blood cell; WBC) imaging. Although they are useful, each of these tests has limitations. Bone scintigraphy is sensitive but not specific, especially when underlying osseous abnormalities are present. "6"7Ga accumulates in tumour, trauma, and in aseptic inflammation; furthermore, there is typically an interval of 1–3 days between radiopharmaceutical injection of and imaging. Currently, this agent is used primarily for spinal infections. Except for the spine, WBC imaging is the nuclear medicine test of choice for diagnosing complicating osteomyelitis. The in vitro leukocyte labelling process requires skilled personnel, is laborious, and is not always available. Complementary marrow imaging is usually required to maximise accuracy. Not surprisingly, alternative radiopharmaceuticals are continuously being investigated. Radiolabelled anti-granulocyte antibodies and antibody fragments, investigated as in vivo leukocyte labelling agents, have their own limitations and are not widely available. "1"1"1In-biotin is useful for diagnosing spinal infections. Radiolabelled synthetic fragments of ubiquicidin, a naturally occurring human antimicrobial peptide that targets bacteria, have shown promise as infection specific radiopharmaceuticals. 2-["1"8F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography (PET) with or without computed tomography (CT) is very useful in musculoskeletal infection. Sensitivities of more than 95% and specificities ranging from 75–99% have

  4. Nuclear imaging of hepatic impact injury on rabbits

    International Nuclear Information System (INIS)

    Jin Rongbing; Wen Jianliang; Tang Weijia; Ma Xiaolin

    2002-01-01

    Objective: To investigate the effect and clinic application value of nuclear imaging on hepatic impact experiment. Methods: Experimental rabbits were impact injured on liver with BIM-IV bio-impact machine. Liver imaging was performed with sodium phytate labeled by 99m Tc. Liver blood pool imaging was performed with labeled red blood cells. The results of imaging were similar with the results of anatomy. Results: There were significant difference between normal liver and injured liver. Radio diminution and defect were showed on injured liver areas in labeled hepatic cells. Many types of abnormal radioactivity distribution were observed in liver pool imaging. The results of liver imaging and liver blood pool imaging were corresponded to the results of anatomy. Conclusion: Changes of hepatic cell structures and function after injury could be showed by nuclear imaging. Nuclear imaging was valuable in determining injured liver position or injured degree

  5. Artificial intelligence as a diagnostic adjunct in cardiovascular nuclear imaging

    International Nuclear Information System (INIS)

    Duncan, J.S.

    1988-01-01

    The radiologist and/or nuclear medicine physician is literally bombarded with information from today's diagnostic imaging technologies. As a consequence of this, whereas a decade ago the emphasis in medical image analysis was on improving the extraction of diagnostic information by developing and using more sophisticated imaging modalities, today those working on the development of medical imaging technology are struggling to find ways to handle all gathered information effectively. This chapter gives an introduction to the area of artificial intelligence, with an emphasis on the research ongoing in cardiovascular nuclear imaging. This chapter has reviewed the place of artificial intelligence in cardiovascular nuclear imaging. It is intended to provide a general sense of this new and emerging field, an insight into some of its specific methodologies and applications, and a closer look at the several AI approaches currently being applied in cardiovascular nuclear imaging

  6. State of the art: noninvasive imaging and management of neurovascular trauma

    Directory of Open Access Journals (Sweden)

    Cothren C Clay

    2007-01-01

    Full Text Available Abstract Neurotrauma represents a significant public health problem, accounting for a significant proportion of the morbidity and mortality associated with all traumatic injuries. Both blunt and penetrating injuries to cervicocerebral vessels are significant and are likely more common than previously recognized. Imaging of such injuries is an important component in the evaluation of individuals presenting with such potential injuries, made all the more important since many of the vascular injuries are clinically silent. Management of injuries, particularly those caused by blunt trauma, is constantly evolving. This article addresses the current state of imaging and treatment of such injuries.

  7. Non-invasive airway health assessment: Synchrotron imaging reveals effects of rehydrating treatments on mucociliary transit in-vivo

    Science.gov (United States)

    Donnelley, Martin; Morgan, Kaye S.; Siu, Karen K. W.; Farrow, Nigel R.; Stahr, Charlene S.; Boucher, Richard C.; Fouras, Andreas; Parsons, David W.

    2014-01-01

    To determine the efficacy of potential cystic fibrosis (CF) therapies we have developed a novel mucociliary transit (MCT) measurement that uses synchrotron phase contrast X-ray imaging (PCXI) to non-invasively measure the transit rate of individual micron-sized particles deposited into the airways of live mice. The aim of this study was to image changes in MCT produced by a rehydrating treatment based on hypertonic saline (HS), a current CF clinical treatment. Live mice received HS containing a long acting epithelial sodium channel blocker (P308); isotonic saline; or no treatment, using a nebuliser integrated within a small-animal ventilator circuit. Marker particle motion was tracked for 20 minutes using PCXI. There were statistically significant increases in MCT in the isotonic and HS-P308 groups. The ability to quantify in vivo changes in MCT may have utility in pre-clinical research studies designed to bring new genetic and pharmaceutical treatments for respiratory diseases into clinical trials.

  8. Multiparametric Functional MRI: Non-Invasive Imaging of Inflammation and Edema Formation after Kidney Transplantation in Mice.

    Directory of Open Access Journals (Sweden)

    Katja Hueper

    Full Text Available Kidney transplantation (ktx in mice is used to learn about rejection and to develop new treatment strategies. Past studies have mainly been based on histological or molecular biological methods. Imaging techniques to monitor allograft pathology have rarely been used.Here we investigated mice after isogenic and allogenic ktx over time with functional MRI with diffusion-weighted imaging (DWI and mapping of T2-relaxation time (T2-mapping to assess graft inflammation and edema formation. To characterize graft pathology, we used PAS-staining, counted CD3-positive T-lymphocytes, analyzed leukocytes by means flow cytometry.DWI revealed progressive restriction of diffusion of water molecules in allogenic kidney grafts. This was paralleled by enhanced infiltration of the kidney by inflammatory cells. Changes in tissue diffusion were not seen following isogenic ktx. T2-times in renal cortex were increased after both isogenic and allogenic transplantation, consistent with tissue edema due to ischemic injury following prolonged cold ischemia time of 60 minutes. Lack of T2 increase in the inner stripe of the inner medulla in allogenic kidney grafts matched loss of tubular autofluorescence and may result from rejection-driven reductions in tubular water content due to tubular dysfunction and renal functional impairment.Functional MRI is a valuable non-invasive technique for monitoring inflammation, tissue edema and tubular function. It permits on to differentiate between acute rejection and ischemic renal injury in a mouse model of ktx.

  9. Noninvasive, low-noise, fast imaging of blood volume and deoxygenation changes in muscles using light-emitting diode continuous-wave imager

    Science.gov (United States)

    Lin, Yuanqing; Lech, Gwen; Nioka, Shoko; Intes, Xavier; Chance, Britton

    2002-08-01

    This article focuses on optimizing the signal to noise ratio (SNR) of a three-wavelength light-emitting diode (LED) near-infrared continuous-wave (cw) imager and its application to in vivo muscle metabolism measurement. The shot-noise limited SNR is derived and calculated to be 2 x104 for the physiological blood concentrations of muscle. Aiming at shot-noise limited SNR performance and fast imaging, we utilize sample and hold circuits to reduce high-frequency noise. These circuits have also been designed to be parallel integrating, through which SNR of 2 x103 and 2 Hz imaging acquisition rate have been achieved when the probe is placed on a muscle model. The noise corresponds to 2 x10-4 optical density error, which suggests an in vitro resolution of 15. 4 nM blood volume and 46.8 nM deoxygenation changes. A 48 dB digital gain control circuit with 256 steps is employed to enlarge the dynamic range of the imager. We utilize cuff ischemia as a living model demonstration and its results are reported. The instrument is applied during exercise to measure the changes of blood volume and deoxygenation, which provides important information about muscle metabolism. We find that the primary source of noise encountered during exercise experiment is from the random motion of muscle. The results demonstrate that the LED cw imager is ideal for the noninvasive study of muscle metabolism.

  10. Value of Cardiovascular Magnetic Resonance Imaging in Noninvasive Risk Stratification in Tetralogy of Fallot

    NARCIS (Netherlands)

    Bokma, Jouke P.; de Wilde, Koen C.; Vliegen, Hubert W.; van Dijk, Arie P.; van Melle, Joost P.; Meijboom, Folkert J.; Zwinderman, Aeilko H.; Groenink, Maarten; Mulder, Barbara J. M.; Bouma, Berto J.

    IMPORTANCE Adults late after total correction of tetralogy of Fallot (TOF) are at risk for majorcomplications. Cardiovascular magnetic resonance (CMR) imaging is recommended toquantify right ventricular (RV) and left ventricular (LV) function. However, a commonly usedrisk model by Khairy et al

  11. Paradox image: a noninvasive index of regional left-ventricular dyskinesis

    International Nuclear Information System (INIS)

    Holman, B.L.; Wynne, J.; Idoine, J.; Zielonka, J.; Neill, J.

    1979-01-01

    The paradox image, a functional image of regional dyskinesis derived from the equilibrium (gated) radionuclide ventriculogram, was constructed by subtracting the background-corrected end-diastolic frame from the background-corrected end-systolic frame. In 11 patients showing dyskinesis by contrast ventriculography, the percentage of left-ventricular picture elements containing paradox ranged from 3.6 to 55.6% (21.44% +- 4.45 s.e.m.). In 11 patients with normokinesis and in eight patients with hypookinesis by contrast ventriculography, the left-ventricular picture elements demonstrating paradox were less than 1.1% in all cases. In nine patients with akinesis, the percentage of left-ventricular picture elements containing paradox was 2.05% +- 0.96 s.e.m. and was less than 2% in seven patients. There was also an excellent agreement between the location of dyskinesis on the paradox image and that by contrast ventriculography. The paradox image is a sensitive indicator of left-ventricular dyskinesis and should be useful in the evaluation of patients with suspected left-ventricular asynergy

  12. Noninvasive imaging of protein metabolic labeling in single human cells using stable isotopes and Raman microscopy

    NARCIS (Netherlands)

    van Manen, H.J.; Lenferink, Aufrid T.M.; Otto, Cornelis

    2008-01-01

    We have combined nonresonant Raman microspectroscopy and spectral imaging with stable isotope labeling by amino acids in cell culture (SILAC) to selectively detect the incorporation of deuterium-labeled phenylalanine, tyrosine, and methionine into proteins in intact, single HeLa cells. The C−D

  13. Noninvasive detection of hepatic lipidosis in dairy cows with calibrated ultrasonographic image analysis.

    NARCIS (Netherlands)

    Starke, A.; Haudum, A.; Weijers, G.; Herzog, K.; Wohlsein, P.; Beyerbach, M.; Korte, C.L. de; Thijssen, J.M.; Rehage, J.

    2010-01-01

    The aim was to test the accuracy of calibrated digital analysis of ultrasonographic hepatic images for diagnosing fatty liver in dairy cows. Digital analysis was performed by means of a novel method, computer-aided ultrasound diagnosis (CAUS), previously published by the authors. This method implies

  14. Nuclear medicine imaging of diabetic foot infection

    International Nuclear Information System (INIS)

    Capriotti, Gabriela; D'Alessandria, Calogero; Signore, Alberto; Chianelli, Marco; Prandini, Napoleone

    2005-01-01

    Full text: Osteomyelitis of the foot is the most frequent complication in diabetic patients. Nuclear medicine plays an important role in diagnosis and for therapy follow-up, using different tracers. We reviewed 57 papers on diabetic foot imaging (published from 1982 to 2004, 50 original papers and 7 reviews), for a total of 2889 lesions. Data analysis has been carried out to establish which imaging technique could be used as a 'gold standard' for diagnosis of infection and to evaluate the extent of disease and to monitor the efficacy of therapy. Data analysis revealed that three-phase bone-scan is sensitive but not specific whereas specificity and diagnostic accuracy of 99m Tc-WBC scintigraphy is higher than 111 In- WBC scintigraphy. In the forefoot leukocyte scintigraphy may be useful for diagnosis of osteomyelitis and for monitoring the response to medical treatment. In the mid/hind foot the leukocytes uptake is not related only to the presence of infected region, but it is attributed to inflammation, fractures and reparative processes. Other radiopharmaceuticals such as 99m Tc/ 111 In-HIG, radiolabelled antibody and their fragments, showed high sensibility, but lower specificity than WBC (96.8/66.5, 95.8/70.2, 91.3/62 vs 85.8/84.5). Conclusion: It emerged that in the forefoot when clinical suspicious of osteomyelitis is low and medical treatment is contemplated, three-phase bon scan is the procedure of choice. A positive test is not diagnostic for osteomyelitis, and radiolabelled WBC scintigraphy is necessary. In the mid/hind foot, diagnosis of neuropathic joint with infection is problematic. Radiolabelled WBC imaging is probably the most accurate test for determining the presence of infection. Although a negative study strongly indicate the absence of osteomyelitis, it is important to note that a positive result requires a complementary study with marrow agent. (author)

  15. 5th German cardiodiagnostic meeting 2013 with the 6th Leipzig Symposium on non-invasive cardiovascular imaging. Challenges and limit of the non-invasive cardiac imaging; 5. Deutsche Kardiodiagnostik-Tage 2013 mit 6. Leipziger Symposium Nichtinvasive Kardiovaskulaere Bildgebung. Herausforderungen und Grenzen der nicht-invasiven kardialen Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-04-01

    The proceedings on the German cardiodiagnostic meeting 2013 together with the 6th Leipzig Symposium on non-invasive cardiovascular imaging include abstracts concerning the following topics: Imaging in the rhythmology; adults with congenital cardiac defects; cardiac myopathies - myocarditis; cardiac valves (before and after transcutaneous valve replacement); coronary heart diseases; technical developments.

  16. Whole mount nuclear fluorescent imaging: convenient documentation of embryo morphology.

    Science.gov (United States)

    Sandell, Lisa L; Kurosaka, Hiroshi; Trainor, Paul A

    2012-11-01

    Here, we describe a relatively inexpensive and easy method to produce high quality images that reveal fine topological details of vertebrate embryonic structures. The method relies on nuclear staining of whole mount embryos in combination with confocal microscopy or conventional wide field fluorescent microscopy. In cases where confocal microscopy is used in combination with whole mount nuclear staining, the resulting embryo images can rival the clarity and resolution of images produced by scanning electron microscopy (SEM). The fluorescent nuclear staining may be performed with a variety of cell permeable nuclear dyes, enabling the technique to be performed with multiple standard microscope/illumination or confocal/laser systems. The method may be used to document morphology of embryos of a variety of organisms, as well as individual organs and tissues. Nuclear stain imaging imposes minimal impact on embryonic specimens, enabling imaged specimens to be utilized for additional assays. Copyright © 2012 Wiley Periodicals, Inc.

  17. NMR clinical imaging and spectroscopy: Its impact on nuclear medicine

    International Nuclear Information System (INIS)

    1990-01-01

    This is a collection of four papers describing aspects of past and future use of nuclear magnetic resonance as a clinical diagnostic tool. The four papers are entitled (1) What Does NMR Offer that Nuclear Medicine Does Not? by Jerry W. Froelich, (2) Oncological Imaging: Now, Future and Impact Jerry W. Froelich, (3) Magnetic Resonance Spectroscopy/Spectroscopic Imaging and Nuclear Medicine: Past, Present and Future by H. Cecil Charles, and (4) MR Cardiology: Now, Future and Impact by Robert J. Herfkens

  18. Internal radiation dosimetry using nuclear medicine imaging in radionuclide therapy

    International Nuclear Information System (INIS)

    Kim, Kyeong Min; Byun, Byun Hyun; Cheon, Gi Jeong; Lim, Sang Moo

    2007-01-01

    Radionuclide therapy has been an important field in nuclear medicine. In radionuclide therapy, relevant evaluation of internally absorbed dose is essential for the achievement of efficient and sufficient treatment of incurable disease, and can be accomplished by means of accurate measurement of radioactivity in body and its changes with time. Recently, the advances of nuclear medicine imaging and multi modality imaging processing techniques can provide chance of more accurate and easier measurement of the measures commented above, in cooperation of conventional imaging based approaches. In this review, basic concept for internal dosimetry using nuclear medicine imaging is summarized with several check points which should be considered in real practice

  19. Noninvasive spectral imaging of skin chromophores based on multiple regression analysis aided by Monte Carlo simulation

    Science.gov (United States)

    Nishidate, Izumi; Wiswadarma, Aditya; Hase, Yota; Tanaka, Noriyuki; Maeda, Takaaki; Niizeki, Kyuichi; Aizu, Yoshihisa

    2011-08-01

    In order to visualize melanin and blood concentrations and oxygen saturation in human skin tissue, a simple imaging technique based on multispectral diffuse reflectance images acquired at six wavelengths (500, 520, 540, 560, 580 and 600nm) was developed. The technique utilizes multiple regression analysis aided by Monte Carlo simulation for diffuse reflectance spectra. Using the absorbance spectrum as a response variable and the extinction coefficients of melanin, oxygenated hemoglobin, and deoxygenated hemoglobin as predictor variables, multiple regression analysis provides regression coefficients. Concentrations of melanin and total blood are then determined from the regression coefficients using conversion vectors that are deduced numerically in advance, while oxygen saturation is obtained directly from the regression coefficients. Experiments with a tissue-like agar gel phantom validated the method. In vivo experiments with human skin of the human hand during upper limb occlusion and of the inner forearm exposed to UV irradiation demonstrated the ability of the method to evaluate physiological reactions of human skin tissue.

  20. Noninvasive Label-Free Detection of Micrometastases in the Lymphatics with Ultrasound-Guided Photoacoustic Imaging

    Science.gov (United States)

    2015-10-01

    imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine ( Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine ( Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US...transducer (L11-4v, Verasonics Inc.) and build a housing which effectively couples fiber optic light delivery. o What opportunities for training and

  1. Non-invasive assessment of pulsatile intracranial pressure with phase-contrast magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Geir Ringstad

    Full Text Available Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of "true" normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43. Pulse pressure gradients were also similar in patients and healthy controls (P = .26, and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97. Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate

  2. Noninvasive imaging of multiple myeloma using near infrared fluorescent molecular probe

    Science.gov (United States)

    Hathi, Deep; Zhou, Haiying; Bollerman-Nowlis, Alex; Shokeen, Monica; Akers, Walter J.

    2016-03-01

    Multiple myeloma is a plasma cell malignancy characterized by monoclonal gammopathy and osteolytic bone lesions. Multiple myeloma is most commonly diagnosed in late disease stages, presenting with pathologic fracture. Early diagnosis and monitoring of disease status may improve quality of life and long-term survival for multiple myeloma patients from what is now a devastating and fatal disease. We have developed a near-infrared targeted fluorescent molecular probe with high affinity to the α4β1 integrin receptor (VLA-4)overexpressed by a majority of multiple myeloma cells as a non-radioactive analog to PET/CT tracer currently being developed for human diagnostics. A near-infrared dye that emits about 700 nm was conjugated to a high affinity peptidomimmetic. Binding affinity and specificity for multiple myeloma cells was investigated in vitro by tissue staining and flow cytometry. After demonstration of sensitivity and specificity, preclinical optical imaging studies were performed to evaluate tumor specificity in murine subcutaneous and metastatic multiple myeloma models. The VLA-4-targeted molecular probe showed high affinity for subcutaneous MM tumor xenografts. Importantly, tumor cells specific accumulation in the bone marrow of metastatic multiple myeloma correlated with GFP signal from transfected cells. Ex vivo flow cytometry of tumor tissue and bone marrow further corroborated in vivo imaging data, demonstrating the specificity of the novel agent and potential for quantitative imaging of multiple myeloma burden in these models.

  3. In vivo non-invasive optical imaging of temperature-sensitive co-polymeric nanohydrogel

    Science.gov (United States)

    Chen, Haiyan; Zhang, Jian; Qian, Zhiyu; Liu, Fei; Chen, Xinyang; Hu, Yuzhu; Gu, Yueqing

    2008-05-01

    Assessment of hyperthermia in pathological tissue is a promising strategy for earlier diagnosis of malignant tumors. In this study, temperature-sensitive co-polymeric nanohydrogel poly(N-isopropylacrylamide-co-acrylic acid) (PNIPA-co-AA) was successfully synthesized by the precipitation polymerization method. The diameters of nanohydrogels were controlled to be less than 100 nm. Also the lower critical solution temperature (LCST, 40 °C) was manipulated above physiological temperature after integration of near-infrared (NIR) organic dye (heptamethine cyanine dye, HMCD) within its interior cores. NIR laser light (765 nm), together with sensitive charge coupled device (CCD) cameras, were designed to construct an NIR imaging system. The dynamic behaviors of PNIPA-co-AA-HMCD composites in denuded mice with or without local hyperthermia treatment were real-time monitored by an NIR imager. The results showed that the PNIPA-co-AA-HMCD composites accumulated in the leg treated with local heating and diffused much slower than that in the other leg without heating. The results demonstrated that the temperature-responsive PNIPA-co-AA-HMCD composites combining with an NIR imaging system could be an effective temperature mapping technique, which provides a promising prospect for earlier tumor diagnosis and thermally related therapeutic assessment.

  4. In vivo non-invasive optical imaging of temperature-sensitive co-polymeric nanohydrogel

    International Nuclear Information System (INIS)

    Chen Haiyan; Hu Yuzhu; Zhang Jian; Liu Fei; Chen Xinyang; Gu Yueqing; Qian Zhiyu

    2008-01-01

    Assessment of hyperthermia in pathological tissue is a promising strategy for earlier diagnosis of malignant tumors. In this study, temperature-sensitive co-polymeric nanohydrogel poly(N-isopropylacrylamide-co-acrylic acid) (PNIPA-co-AA) was successfully synthesized by the precipitation polymerization method. The diameters of nanohydrogels were controlled to be less than 100 nm. Also the lower critical solution temperature (LCST, 40 deg. C) was manipulated above physiological temperature after integration of near-infrared (NIR) organic dye (heptamethine cyanine dye, HMCD) within its interior cores. NIR laser light (765 nm), together with sensitive charge coupled device (CCD) cameras, were designed to construct an NIR imaging system. The dynamic behaviors of PNIPA-co-AA-HMCD composites in denuded mice with or without local hyperthermia treatment were real-time monitored by an NIR imager. The results showed that the PNIPA-co-AA-HMCD composites accumulated in the leg treated with local heating and diffused much slower than that in the other leg without heating. The results demonstrated that the temperature-responsive PNIPA-co-AA-HMCD composites combining with an NIR imaging system could be an effective temperature mapping technique, which provides a promising prospect for earlier tumor diagnosis and thermally related therapeutic assessment

  5. Noninvasive imaging of human skin hemodynamics using a digital red-green-blue camera

    Science.gov (United States)

    Nishidate, Izumi; Tanaka, Noriyuki; Kawase, Tatsuya; Maeda, Takaaki; Yuasa, Tomonori; Aizu, Yoshihisa; Yuasa, Tetsuya; Niizeki, Kyuichi

    2011-08-01

    In order to visualize human skin hemodynamics, we investigated a method that is specifically developed for the visualization of concentrations of oxygenated blood, deoxygenated blood, and melanin in skin tissue from digital RGB color images. Images of total blood concentration and oxygen saturation can also be reconstructed from the results of oxygenated and deoxygenated blood. Experiments using tissue-like agar gel phantoms demonstrated the ability of the developed method to quantitatively visualize the transition from an oxygenated blood to a deoxygenated blood in dermis. In vivo imaging of the chromophore concentrations and tissue oxygen saturation in the skin of the human hand are performed for 14 subjects during upper limb occlusion at 50 and 250 mm Hg. The response of the total blood concentration in the skin acquired by this method and forearm volume changes obtained from the conventional strain-gauge plethysmograph were comparable during the upper arm occlusion at pressures of both 50 and 250 mm Hg. The results presented in the present paper indicate the possibility of visualizing the hemodynamics of subsurface skin tissue.

  6. Noninvasive imaging of brain oxygen metabolism in children with primary nocturnal enuresis during natural sleep.

    Science.gov (United States)

    Yu, Bing; Huang, Mingzhu; Zhang, Xu; Ma, Hongwei; Peng, Miao; Guo, Qiyong

    2017-05-01

    A series of studies have revealed that nocturnal enuresis is closely related to hypoxia in children with primary nocturnal enuresis (PNE). However, brain oxygen metabolism of PNE children has not been investigated before. The purpose of this study was to investigate changes in whole-brain cerebral metabolic rate of oxygen (CMRO 2 ), cerebral blood flow (CBF), and oxygen extraction fraction (OEF) in children suffering from PNE. We used the newly developed T2-relaxation-under-spin-tagging (TRUST) magnetic resonance imaging technique. Neurological evaluation, structural imaging, phase-contrast, and the TRUST imaging method were applied in children with PNE (n = 37) and healthy age- and sex-matched control volunteers (n = 39) during natural sleep to assess whole-brain CMRO 2 , CBF, OEF, and arousal from sleep scores. Results showed that whole-brain CMRO 2 and OEF values of PNE children were higher in controls, while there was no significant difference in CBF. Consequently, OEF levels of PNE children were increased to maintain oxygen supply. The elevation of OEF was positively correlated with the difficulty of arousal. Our results provide the first evidence that high oxygen consumption and high OEF values could make PNE children more susceptible to hypoxia, which may induce cumulative arousal deficits and make them more prone to nocturnal enuresis. Hum Brain Mapp 38:2532-2539, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. A red fluorescent nude mouse model of human endometriosis: advantages of a non-invasive imaging method.

    Science.gov (United States)

    Wang, Ningning; Hong, Shanshan; Tan, Jinfeng; Ke, Peiqi; Liang, Lili; Fei, Hui; Liu, Bin; Liu, Liqun; Liu, Yongdong; Yu, Bingjun

    2014-05-01

    To establish red fluorescent human endometriosis lesions in a nude mouse model and dynamically and non-invasively to compare intraperitoneal and subcutaneous injection models. Primary cultures of endometrial stromal cells (ESCs) and epithelial cells (EECs) isolated from 24 patients with a normal uterine cavity were transfected with 2.5×10(8) (Group 1) and 1.25×10(8) (Group 2) plaque-forming units (PFU) of adenovirus encoding red fluorescent protein (Ad-RFP). Transfection efficiencies, fluorescence intensity and apoptosis rate of the two types of cells were compared in vitro. A mixture of 2.5×10(8) PFU Ad-RFP-infected approximately 400 EECs cell mass and 2×10(6) ESCs for 36h was injected individually into 24 female nude mice subcutaneously (Group A) or intraperitoneally (Group B). From Day 5 after injection, an in vivo imaging system (IVIS) was used to non-invasively observe and compare the lesions of the two groups every week until Day 33. Specifically, the fluorescent intensity, positive rates, persistence time and lesion weight in the implanted human endometriosis lesions were compared. A parametric Student's t-test and two-way analysis of variance were used for statistical analysis. Compared with 1.25×10(8) PFU RFP, a titre of 2.5×10(8) PFU RFP ESCs and EECs incubated for 36h exhibited higher transfection efficiencies and higher fluorescence intensities in vitro. In vivo imaging of the fluorescent human endometriosis lesions originating from an RFP titre of 2.5×10(8) PFU showed that the intensity and lesion weight in Group A were significantly higher than in Group B. However, the two groups had the same RFP-positive rates and fluorescence persistence. The structure of each lesion was evaluated by immunohistochemistry to confirm its human endometrial origin. The red fluorescent human endometriosis model established by subcutaneously injecting 2.5×10(8) PFU RFP-transfected stromal cells and epithelial cells into nude mice had a higher fluorescent positive

  8. Non-invasive imaging of acute renal allograft rejection in rats using small animal F-FDG-PET.

    Directory of Open Access Journals (Sweden)

    Stefan Reuter

    Full Text Available BACKGROUND: At present, renal grafts are the most common solid organ transplants world-wide. Given the importance of renal transplantation and the limitation of available donor kidneys, detailed analysis of factors that affect transplant survival are important. Despite the introduction of new and effective immunosuppressive drugs, acute cellular graft rejection (AR is still a major risk for graft survival. Nowadays, AR can only be definitively by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Most important, they can not be performed in patients taking anticoagulant drugs. METHODOLOGY/PRINCIPAL FINDINGS: We present a non-invasive, entirely image-based method to assess AR in an allogeneic rat renal transplantation model using small animal positron emission tomography (PET and (18F-fluorodeoxyglucose (FDG. 3 h after i.v. injection of 30 MBq FDG into adult uni-nephrectomized, allogeneically transplanted rats, tissue radioactivity of renal parenchyma was assessed in vivo by a small animal PET-scanner (post operative day (POD 1,2,4, and 7 and post mortem dissection. The mean radioactivity (cps/mm(3 tissue as well as the percent injected dose (%ID was compared between graft and native reference kidney. Results were confirmed by histological and autoradiographic analysis. Healthy rats, rats with acute CSA nephrotoxicity, with acute tubular necrosis, and syngeneically transplanted rats served as controls. FDG-uptake was significantly elevated only in allogeneic grafts from POD 1 on when compared to the native kidney (%ID graft POD 1: 0.54+/-0.06; POD 2: 0.58+/-0.12; POD 4: 0.81+/-0.06; POD 7: 0.77+/-0.1; CTR: 0.22+/-0.01, n = 3-28. Renal FDG-uptake in vivo correlated with the results obtained by micro-autoradiography and the degree of inflammatory infiltrates observed in histology. CONCLUSIONS/SIGNIFICANCE: We propose that graft FDG-PET imaging is a new option to non-invasively, specifically, early detect, and follow

  9. Nuclear magnetic resonance (NMR) imaging of Arnold-Chiari type I malformation with hydromyelia

    International Nuclear Information System (INIS)

    DeLaPaz, R.L.; Brady, T.J.; Buonanno, F.S.; New, P.F.; Kistler, J.P.; McGinnis, B.D.; Pykett, I.L.; Taveras, J.M.

    1983-01-01

    Saturation recovery nuclear magnetic resonance (NMR) images and metrizamide computed tomography (CT) scans were obtained in an adult patient with a clinical history suggestive of syringomyelia. Both NMR and CT studies showed low lying cerebellar tonsils. The CT study demonstrated central cavitation of the spinal cord from the midthoracic to midcervical levels but could not exclude an intramedullary soft tissue mass at the cervico-medullary junction. The NMR images in transverse, coronal, and sagittal planes demonstrated extension of an enlarged central spinal cord cerebrospinal fluid space to the cervico-medullary junction. This was felt to be strong evidence for exclusion of an intramedullary soft tissue mass and in favor of a diagnosis of Arnold-Chiari Type I malformation with hydromyelia. The noninvasive nature of spinal cord and cervico-medullary junction evaluation with NMR is emphasized

  10. Noninvasive imaging of tumor integrin expression using 18F-labeled RGD dimer peptide with PEG4 linkers

    International Nuclear Information System (INIS)

    Liu, Zhaofei; Liu, Shuanglong; Wang, Fan; Liu, Shuang; Chen, Xiaoyuan

    2009-01-01

    Various radiolabeled Arg-Gly-Asp (RGD) peptides have been previously investigated for tumor integrin α v β 3 imaging. To further develop RGD radiotracers with enhanced tumor-targeting efficacy and improved in vivo pharmacokinetics, we designed a new RGD homodimeric peptide with two PEG 4 spacers (PEG 4 = 15-amino-4,7,10,13-tetraoxapentadecanoic acid) between the two monomeric RGD motifs and one PEG 4 linker on the glutamate α-amino group ( 18 F-labeled PEG 4 -E[PEG 4 -c(RGDfK)] 2 , P-PRGD2), as a promising agent for noninvasive imaging of integrin expression in mouse models. P-PRGD2 was labeled with 18 F via 4-nitrophenyl 2- 18 F-fluoropropionate ( 18 F-FP) prosthetic group. In vitro and in vivo characteristics of the new dimeric RGD peptide tracer 18 F-FP-P-PRGD2 were investigated and compared with those of 18 F-FP-P-RGD2 ( 18 F-labeled RGD dimer without two PEG 4 spacers between the two RGD motifs). The ability of 18 F-FP-P-PRGD2 to image tumor vascular integrin expression was evaluated in a 4T1 murine breast tumor model. With the insertion of two PEG 4 spacers between the two RGD motifs, 18 F-FP-P-PRGD2 showed enhanced integrin α v β 3 -binding affinity, increased tumor uptake and tumor-to-nontumor background ratios compared with 18 F-FP-P-RGD2 in U87MG tumors. MicroPET imaging with 18 F-FP-P-PRGD2 revealed high tumor contrast and low background in tumor-bearing nude mice. Biodistribution studies confirmed the in vivo integrin α v β 3 -binding specificity of 18 F-FP-P-RGD2. 18 F-FP-P-PRGD2 can specifically image integrin α v β 3 on the activated endothelial cells of tumor neovasculature. 18 F-FP-P-PRGD2 can provide important information on integrin expression on the tumor vasculature. The high integrin binding affinity and specificity, excellent pharmacokinetic properties and metabolic stability make the new RGD dimeric tracer 18 F-FP-P-PRGD2 a promising agent for PET imaging of tumor angiogenesis and for monitoring the efficacy of antiangiogenic

  11. Double contrast barium enema combined with non-invasive imaging in peritoneal mesothelioma

    International Nuclear Information System (INIS)

    Cozzi, G.; Bellomi, M.; Frigerio, L.F.; Ostinelli, C.; Marchiano, A.; Petrillo, R.; Severini, A.; Milan Univ.

    1989-01-01

    Mesotheliomas are rare tumors arising from serosal linings of the major serous cavities. Five patients with peritoneal mesothelioma underwent a double contrast barium enema (DCBE) and ultrasonography (US) (2 patients), computed tomography (CT) (3 patients) and/or magnetic resonance imaging (MRI) (3 patients). The diagnosis was confirmed at laparotomy. The radiologic pattern at DCBE is unspecific and consists of compression and dislocation of bowel loops by extrinsic masses. Mesenteric retraction and segmental stenosis may be present. In one patient DCBE was normal. US, CT and MRI findings are also unspecific but when combined with information obtained from DCBE the site and abdominal extension of the disease are well defined. (orig.)

  12. Characterizing the inflammatory tissue response to acute myocardial infarction by clinical multimodality noninvasive imaging.

    Science.gov (United States)

    Wollenweber, Tim; Roentgen, Philipp; Schäfer, Andreas; Schatka, Imke; Zwadlo, Caroline; Brunkhorst, Thomas; Berding, Georg; Bauersachs, Johann; Bengel, Frank M

    2014-09-01

    Myocardial infarction (MI) triggers a systemic inflammatory response which determines subsequent healing. Experimentally, cardiac positron emission tomography and magnetic resonance imaging have been used successfully to obtain mechanistic insights. We explored the translational potential in patients early after MI. Positron emission tomography/computed tomography and cardiac magnetic resonance were performed in 15 patients sources of inflammatory cells. Positron emission tomography and cardiac magnetic resonance multimodality characterization of the acutely infarcted, inflamed myocardium may provide multiparametric end points for clinical studies aiming at support of infarct healing. © 2014 American Heart Association, Inc.

  13. Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating-phantom results

    International Nuclear Information System (INIS)

    Daniels, M J; Varghese, T; Madsen, E L; Zagzebski, J A

    2007-01-01

    Minimally invasive therapies (such as radiofrequency ablation) are becoming more commonly used in the United States for the treatment of hepatocellular carcinomas and liver metastases. Unfortunately, these procedures suffer from high recurrence rates of hepatocellular carcinoma (∼34-55%) or metastases following ablation therapy. The ability to perform real-time temperature imaging while a patient is undergoing radiofrequency ablation could provide a significant reduction in these recurrence rates. In this paper, we demonstrate the feasibility of ultrasound-based temperature imaging on a tissue-mimicking phantom undergoing radiofrequency heating. Ultrasound echo signals undergo time shifts with increasing temperature, which are tracked using 2D correlation-based speckle tracking methods. Time shifts or displacements in the echo signal are accumulated, and the gradient of these time shifts are related to changes in the temperature of the tissue-mimicking phantom material using a calibration curve generated from experimental data. A tissue-mimicking phantom was developed that can undergo repeated radiofrequency heating procedures. Both sound speed and thermal expansion changes of the tissue-mimicking material were measured experimentally and utilized to generate the calibration curve relating temperature to the displacement gradient. Temperature maps were obtained, and specific regions-of-interest on the temperature maps were compared to invasive temperatures obtained using fiber-optic temperature probes at the same location. Temperature elevation during a radiofrequency ablation procedure on the phantom was successfully tracked to within ±0.5 0 C

  14. Simultaneous acquisition of physiological data and nuclear medicine images

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; Klein, H.A.; Orenstein, S.R.

    1988-01-01

    A technique has been developed that allows the simultaneous acquisition of both image and physiological data into a standard nuclear medicine computer system. The physiological data can be displayed along with the nuclear medicine images allowing temporal correlation between the two. This technique has been used to acquire images of gastroesophageal reflux simultaneously with the intraluminal esophageal pH. The resulting data are displayed either as a standard dynamic sequence with the physiological data appearing in a corner of the image or as condensed dynamic images

  15. Non-invasive perfusion imaging by modified STAR using asymmetric inversion slabs (ASTAR)

    International Nuclear Information System (INIS)

    Kimura, Tokunori

    2000-01-01

    Arterial spin labeling (ASL) such as STAR, EPISTAR, and FAIR have been used as imaging techniques of tissue perfusion and blood vessels (in MRA). We have developed 'ASTAR', a modified version of STAR by using asymmetric inversion slabs. ASTAR solves the problems of suppression of venous inflow and subtraction error of stationary tissue signal caused by the imbalance of signal variations. The signal variations are dependent on MT effects. In order to avoid overlapping the control slab to the tissue (including large veins), the control and tag slabs are arranged asymmetrically to preserve the same offset of modulation frequency. We evaluated both the subtraction error caused by the MT effects, and the imperfection of an IR slab using a stationary phantom. We then measured the vessel signal on the brain of a volunteer, using the above methods. Two indexes were used for the evaluation: ASL signal to control signal ratio (ASLR [%]=100*deltaS/S cont ) and ASL signal to noise ratio (ASLNR=delatS/Noise) where deltaS=|S cont -S tag |. Phantom study: each ASLR and ASLNR between ASTAR and EPISTAR was comparable and showed a decrease in noise signal level. This means that the ASL signal from the stationary tissue with an imbalance in MT effects and the imperfection in inversion slab profiles were cancelled out almost perfectly. When calculating CBF, ASLR for zero perfusion stationary tissue should be below 0.1%. We were able to satisfy this requirement in our ASTAR experiment. ASLR and ASLNR in FAIR were 40% larger than in EPISTAR and ASTAR. Volunteer brain study: compared with each ASL image, the MT effects were cancelled out in EPISTAR and ASTAR. Veins (sagittal sinus etc) disappeared in STAR and ASTAR, but were visible in EPISTAR and FAIR. Perfusion signals were similar in ASTAR and EPISTAR, indicating that both cancellation of MT effects and venous inflow from the opposite side of the tag were suppressed in ASTAR. In conclusion, ASTAR is a practical method to image blood

  16. Noninvasive imaging of malignant tumors using laminin peptide fragments YIGSR labeled with Technetium-99m

    International Nuclear Information System (INIS)

    Qin, G.M.; Zhang, Y.X.; Hu, J.; An, R.; Gao, Z.R.; Cao, G.X.; Hnatowich, D.J.

    2002-01-01

    The radiopharmaceuticals that localize specifically at certain sites (such as peptides directed against receptors expressed on tumor cells or antibodies with high binding affinities for bacterial determinants) may be expected to display greater specificity of localization. Peptides, which diffuse rapidly into target lesions and clear rapidly elsewhere, may be expected to enjoy a pharmacokinetic advantage over those, such as antibodies, which accumulate and clear more slowly. The laminin peptide fragments YIGSR is known to bind to a 67-kDa laminin receptor. This receptor is understood to be expressed at higher than normal levels in malignant tumor cells, particularly those of breast and colon carcinomas. Methods 1 peptide conjugation and labeling A 2.5 mg/mL solution of YIGSR in 0.1 M N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid (HEPES) buffer, pH8.0, and a fresh 10mg/mL solution of NHS-S-acetyl-MAG 3 in dimethylformamide dried over molecular sieve were prepared. 2 biodistribution and imaging studies A colony of KM mice (15-20g) were inoculated with 1x10 6 Ehrlich (breast) carcinoma tumor cells in the right thigh, and the tumors were allowed to grow for 6-7 days to a size of 1.0-1.5 cm in diameter. Biodistribution studies were performed in 40 KM mice after 50 μCi per mouse of 99m Tc-labeled YIGSR were injected intravenously. A total of 10 mice were injected intravenously in the tail vein with 1-2 mCi of 99m Tc-labeled YIGSR, immobilized with ketamine hydrochloride and imaged periodically from 0.5 hr to 24 hr with a gamma camera. The identical imaging procedure was also performed in mice with sterile infection/inflammation lesions to evaluate the specificity. Results Essentially complete conjugation was achieved by reverse-phase Sep-Pak C18 chromatography analysis. The highest accumulation of label was in the kidney first, with the liver and small bowel next. The injected activity localized in the lesion as early as 15 min and reached a saturation value at 3

  17. Dobutamine stress magnetic resonance imaging: a valuable method in the noninvasive diagnosis of ischemic heart disease.

    Science.gov (United States)

    van Dijkman, Paul R M; Kuijpers, Dirkjan A; Blom, Bernadette M; van Herpen, Gerard

    2002-01-01

    We assessed the clinical applicability of dobutamine stress magnetic resonance imaging (DS-MRI) for the detection of myocardial ischemia and myocardial viability. One hundred patients with suspected coronary artery disease and inconclusive exercise electrocardiography or significant repolarization abnormalities on the resting ECG underwent breath hold DS-MRI (1 Tesla), 4 days after cessation of anti-ischemic medication. Three left ventricular short axis planes were imaged at increasing doses of dobutamine. Recovery of wall thickening in a previously diminished or non contracting segment at low dose dobutamine was considered proof of viability. Development of hypo-, a- or dyskinesia at higher doses of dobutamine was taken to indicate ischemia. If the DS-MRI test was positive for ischemia, coronary angiography was performed. If indicated, this was followed by revascularization. If DS-MRI did not demonstrate ischemia, neither angiography nor revascularization were carried out. Ninety five DS-MRI investigations were available for diagnosis. Forty two patients had DS-MRI scans positive for ischemia and subsequently coronary angiography assessment of the clinical applicability of DS-MRI for the detection of myocardial ischemia was performed. One patient was false-positive. All 53 patients with non-ischemic DS-MRI scans had follow-up for 11-23 months (mean 17 months). One patient died suddenly 2 weeks after the MRI-test. The other 52 patients did not experience any coronary event nor sudden cardiac death. The predictive value of a positive (for ischemia) DS-MRI test is 98% and the predictive value of a negative DS-MRI test is also 98%.

  18. Noninvasive staging of lung cancer. Indications and limitations of gallium-67 citrate imaging

    International Nuclear Information System (INIS)

    Bekerman, C.; Caride, V.J.; Hoffer, P.B.; Boles, C.A.

    1990-01-01

    The results of evaluation of the hila and mediastinum with 67Ga scans are contradictory, as are the recommendations by different investigators on the use of 67Ga scintigraphy in the clinical evaluation of patients with primary lung carcinoma. Nevertheless, the economy and logistic simplicity of evaluating local and distant metastases with a single imaging procedure are attractive, especially because the symptoms may not enable the physician to make a correct identification of the organ systems affected by metastases. Neumann and Hoffer state that at present conventional Ga-67 scanning techniques cannot be recommended for preoperative staging of mediastinal lymph node metastases in lung cancer patients. According to Waxman, 67Ga scintigraphy, relative to other imaging modalities, is a sensitive indicator of hilar spread of a tumor. However, because of the normally high background activity within the sternum and spine, mediastinal abnormalities may be poorly detected. Since most pulmonary tumors metastasize via regional nodes to the pulmonary hilum and then to the mediastinum, the high sensitivity for the detection of pulmonary hilar abnormalities and the high specificity for detection of mediastinal lesions suggest that gallium scintigraphy is a valuable adjunctive test when used appropriately. The results obtained locally are probably the best guide for individual physicians in the selection of diagnostic tests for their patients. Gallium scans may thus be helpful in the clinical evaluation of patients with lung cancer. Although gallium scans identify mediastinal node involvement, there is considerable controversy over the relationship between the sensitivity and specificity of the method. By detecting distant extrathoracic metastases, the 67Ga scan may identify a small group of patients who can be spared a needless operation. 92 references

  19. Video image processing for nuclear safeguards

    International Nuclear Information System (INIS)

    Rodriguez, C.A.; Howell, J.A.; Menlove, H.O.; Brislawn, C.M.; Bradley, J.N.; Chare, P.; Gorten, J.

    1995-01-01

    The field of nuclear safeguards has received increasing amounts of public attention since the events of the Iraq-UN conflict over Kuwait, the dismantlement of the former Soviet Union, and more recently, the North Korean resistance to nuclear facility inspections by the International Atomic Energy Agency (IAEA). The role of nuclear safeguards in these and other events relating to the world's nuclear material inventory is to assure safekeeping of these materials and to verify the inventory and use of nuclear materials as reported by states that have signed the nuclear Nonproliferation Treaty throughout the world. Nuclear safeguards are measures prescribed by domestic and international regulatory bodies such as DOE, NRC, IAEA, and EURATOM and implemented by the nuclear facility or the regulatory body. These measures include destructive and non destructive analysis of product materials/process by-products for materials control and accountancy purposes, physical protection for domestic safeguards, and containment and surveillance for international safeguards

  20. Noninvasive monitoring of cancer therapy induced activated T cells using [18F]FB-IL-2 PET imaging.

    Science.gov (United States)

    Hartimath, S V; Draghiciu, O; van de Wall, S; Manuelli, V; Dierckx, R A J O; Nijman, H W; Daemen, T; de Vries, E F J

    2017-01-01

    Cancer immunotherapy urgently calls for methods to monitor immune responses at the site of the cancer. Since activated T lymphocytes may serve as a hallmark for anticancer responses, we targeted these cells using the radiotracer N-(4-[ 18 F]fluorobenzoyl)-interleukin-2 ([ 18 F]FB-IL-2) for positron emission tomography (PET) imaging. Thus, we noninvasively monitored the effects of local tumor irradiation and/or immunization on tumor-infiltrating and systemic activated lymphocytes in tumor-bearing mice. A 10- and 27-fold higher [ 18 F]FB-IL-2 uptake was observed in tumors of mice receiving tumor irradiation alone or in combination with immunization, respectively. This increased uptake was extended to several non-target tissues. Administration of the CXCR4 antagonist AMD3100 reduced tracer uptake by 2.8-fold, indicating a CXCR4-dependent infiltration of activated T lymphocytes upon cancer treatment. In conclusion, [ 18 F]FB-IL-2 PET can serve as a clinical biomarker to monitor treatment-induced infiltration of activated T lymphocytes and, on that basis, may guide cancer immunotherapies.

  1. Feasibility study of the non-invasive estimation of the β+ arterial input function for human PET imaging

    International Nuclear Information System (INIS)

    Hubert, X.

    2009-12-01

    This work deals with the estimation of the concentration of molecules in arterial blood which are labelled with positron-emitting radioelements. This concentration is called 'β + arterial input function'. This concentration has to be estimated for a large number of pharmacokinetic analyses. Nowadays it is measured through series of arterial sampling, which is an accurate method but requiring a stringent protocol. Complications might occur during arterial blood sampling because this method is invasive (hematomas, nosocomial infections). The objective of this work is to overcome this risk through a non-invasive estimation of β + input function with an external detector and a collimator. This allows the reconstruction of blood vessels and thus the discrimination of arterial signal from signals in other tissues. Collimators in medical imaging are not adapted to estimate β + input function because their sensitivity is very low. During this work, they are replaced by coded-aperture collimators, originally developed for astronomy. New methods where coded apertures are used with statistical reconstruction algorithms are presented. Techniques for analytical ray-tracing and for the acceleration of reconstructions are proposed. A new method which decomposes reconstructions on temporal sets and on spatial sets is also developed to efficiently estimate arterial input function from series of temporal acquisitions. This work demonstrates that the trade-off between sensitivity and spatial resolution in PET can be improved thanks to coded aperture collimators and statistical reconstruction algorithm; it also provides new tools to implement such improvements. (author)

  2. Burn-injured tissue detection for debridement surgery through the combination of non-invasive optical imaging techniques.

    Science.gov (United States)

    Heredia-Juesas, Juan; Thatcher, Jeffrey E; Lu, Yang; Squiers, John J; King, Darlene; Fan, Wensheng; DiMaio, J Michael; Martinez-Lorenzo, Jose A

    2018-04-01

    The process of burn debridement is a challenging technique requiring significant skills to identify the regions that need excision and their appropriate excision depths. In order to assist surgeons, a machine learning tool is being developed to provide a quantitative assessment of burn-injured tissue. This paper presents three non-invasive optical imaging techniques capable of distinguishing four kinds of tissue-healthy skin, viable wound bed, shallow burn, and deep burn-during serial burn debridement in a porcine model. All combinations of these three techniques have been studied through a k-fold cross-validation method. In terms of global performance, the combination of all three techniques significantly improves the classification accuracy with respect to just one technique, from 0.42 up to more than 0.76. Furthermore, a non-linear spatial filtering based on the mode of a small neighborhood has been applied as a post-processing technique, in order to improve the performance of the classification. Using this technique, the global accuracy reaches a value close to 0.78 and, for some particular tissues and combination of techniques, the accuracy improves by 13%.

  3. High-resolution non-invasive 3D imaging of paint microstructure by synchrotron-based X-ray laminography

    International Nuclear Information System (INIS)

    Reischig, Peter; Helfen, Lukas; Wallert, Arie; Baumbach, Tilo; Dik, Joris

    2013-01-01

    The characterisation of the microstructure and micromechanical behaviour of paint is key to a range of problems related to the conservation or technical art history of paintings. Synchrotron-based X-ray laminography is demonstrated in this paper to image the local sub-surface microstructure in paintings in a non-invasive and non-destructive way. Based on absorption and phase contrast, the method can provide high-resolution 3D maps of the paint stratigraphy, including the substrate, and visualise small features, such as pigment particles, voids, cracks, wood cells, canvas fibres etc. Reconstructions may be indicative of local density or chemical composition due to increased attenuation of X-rays by elements of higher atomic number. The paint layers and their interfaces can be distinguished via variations in morphology or composition. Results of feasibility tests on a painting mockup (oak panel, chalk ground, vermilion and lead white paint) are shown, where lateral and depth resolution of up to a few micrometres is demonstrated. The method is well adapted to study the temporal evolution of the stratigraphy in test specimens and offers an alternative to destructive sampling of original works of art. (orig.)

  4. High-resolution magnetic resonance imaging of rotator cuff tears using a microscopy coil. Noninvasive detection without intraarticular contrast material

    International Nuclear Information System (INIS)

    Hitachi, Shin; Takase, Kei; Higano, Shuichi; Takahashi, Shoki; Tanaka, Minoru; Tojo, Yuichi; Tabata, Shiro; Majima, Kazuhiro

    2011-01-01

    The aim of this study was to evaluate the feasibility of high-resolution magnetic resonance imaging (MRI) using a microscopy coil for the diagnosis of rotator cuff tears by comparing the method to conventional MRI and MRI arthrography. A total of 68 shoulders were prospectively studied using a 1.5-T MRI unit. Conventional MRI scans were obtained with a surface coil and high-resolution MRI scans with a microscopy coil. MRI arthrography was performed in 28 shoulders using a surface coil. MRI evaluation of tears of rotator cuff tendons was compared with arthroscopic findings and surgical results. The surgery revealed 40 full-thickness tears, 13 partial-thickness tears, and 15 intact cuffs. In all, 35 (88%) full-thickness tears were correctly diagnosed on conventional MRI and 40 (100%) on high-resolution MRI. MR arthrography delineated 11 of 12 (92%) full-thickness tears. Altogether, 5 (38%) of the partial-thickness tears were detected on conventional MRI, and 12 (92%) were clearly demonstrated on high-resolution MRI. MRI arthrography depicted three (60%) of five partial-thickness tears. High-resolution MRI showed higher sensitivity than conventional MRI (P<0.05) and had values equivalent to those of MRI arthrography for diagnosing partial-thickness tears. High-resolution MRI with a microscopy coil is a feasible, noninvasive technique for diagnosing rotator cuff tears. (author)

  5. Noninvasive measurements of cardiac high-energy phosphate metabolites in dilated cardiomyopathy by using 31P spectroscopic chemical shift imaging

    International Nuclear Information System (INIS)

    Hansch, A.; Rzanny, R.; Heyne, J.-P.; Reichenbach, J.R.; Kaiser, W.A.; Leder, U.

    2005-01-01

    Dilated cardiomyopathy (DCM) is accompanied by an impaired cardiac energy metabolism. The aim of this study was to investigate metabolic ratios in patients with DCM compared to controls by using spectroscopic two-dimensional chemical shift imaging (2D-CSI). Twenty volunteers and 15 patients with severe symptoms (left ventricular ejection fraction, LVEF 30%) of DCM were investigated. Cardiac 31 P MR 2D-CSI measurements (voxel size: 40 x 40 x 100 mm 3 ) were performed with a 1.5 T whole-body scanner. Measurement time ranged from 15 min to 30 min. Peak areas and ratios of different metabolites were evaluated, including high-energy phosphates (PCr, ATP), 2,3-diphosphoglycerate (2,3-DPG) and phosphodiesters (PDE). In addition, we evaluated how PCr/ATP ratios correlate with LVEF as an established prognostic factor of heart failure. The PCr/γ-ATP ratio was significantly decreased in patients with moderate and severe DCM and showed a linear correlation with reduced LVEFs. PDE/ATP ratios were significantly increased only in patients with severe DCM as compared to volunteers. Applying 31 P MRS with commonly-available 2D-CSI sequences is a valuable technique to evaluate DCM by determining PCr/ATP ratios noninvasively. In addition to reduced PCr/ATP ratios observed in patients suffering from DCM, significantly-increased PDE/ATP ratios were found in patients with severe DCM. (orig.)

  6. Non-invasive imaging of tumors by monitoring autotaxin activity using an enzyme-activated near-infrared fluorogenic substrate.

    Directory of Open Access Journals (Sweden)

    Damian Madan

    Full Text Available Autotaxin (ATX, an autocrine motility factor that is highly upregulated in metastatic cancer, is a lysophospholipase D enzyme that produces the lipid second messenger lysophosphatidic acid (LPA from lysophosphatidylcholine (LPC. Dysregulation of the lysolipid signaling pathway is central to the pathophysiology of numerous cancers, idiopathic pulmonary fibrosis, rheumatoid arthritis, and other inflammatory diseases. Consequently, the ATX/LPA pathway has emerged as an important source of biomarkers and therapeutic targets. Herein we describe development and validation of a fluorogenic analog of LPC (AR-2 that enables visualization of ATX activity in vivo. AR-2 exhibits minimal fluorescence until it is activated by ATX, which substantially increases fluorescence in the near-infrared (NIR region, the optimal spectral window for in vivo imaging. In mice with orthotopic ATX-expressing breast cancer tumors, ATX activated AR-2 fluorescence. Administration of AR-2 to tumor-bearing mice showed high fluorescence in the tumor and low fluorescence in most healthy tissues with tumor fluorescence correlated with ATX levels. Pretreatment of mice with an ATX inhibitor selectively decreased fluorescence in the tumor. Together these data suggest that fluorescence directly correlates with ATX activity and its tissue expression. The data show that AR-2 is a non-invasive and selective tool that enables visualization and quantitation of ATX-expressing tumors and monitoring ATX activity in vivo.

  7. Noninvasive Localization of Accessory Pathways in Patients with Wolff-Parkinson-White Syndrome: A Strain Imaging Study

    Science.gov (United States)

    Esmaeilzadeh, Maryam; Omran, Mohammad Taghi Salehi; Maleki, Majid; Haghjoo, Majid; Noohi, Feridoun; Haghighi, Zahra Ojaghi; Sadeghpour, Anita; Davari, Paridokht Nakhostin; Abkenar, Hooman Bakhshandeh

    2013-01-01

    Background: Noninvasive techniques for the localization of the accessory pathways (APs) might help guide mapping procedures and ablation techniques. We sought to examine the diagnostic accuracy of strain imaging for the localization of the APs in Wolff-Parkinson-White syndrome. Methods: We prospectively studied 25 patients (mean age = 32 ± 17 years, 58.3% men) with evidence of pre-excitation on electrocardiography (ECG). Electromechanical interval was defined as the time difference between the onset of delta wave and the onset of regional myocardial contraction. Time differences between the onset of delta wave (δ) and the onset of regional myocardial contraction (δ-So), peak systolic motion (δ-Sm), regional strain (δ-ε), peak strain (δ-εp), and peak strain rate (δ-SRp) were measured. Results: There was a significant difference between time to onset of delta wave to onset of peak systolic motion (mean ± SD) in the AP location (A) and normal segments (B) versus that in the normal volunteers (C) [A: (57.08 ± 23.88 msec) vs. B: (75.20 ± 14.75) vs. C: (72.9 0 ± 11.16); p value (A vs. B) = 0.004 and p value (A vs. C) = 0.18] and [A: (49.17 ± 35.79) vs. B: (67.60 ± 14.51) vs. C: (67.40 ± 6.06 msec); p value (A vs. B) < 0.001 and p value (A vs. C) = 0.12, respectively]. Conclusion: Our study showed that strain imaging parameters [(δ-So) and (δ-Strain)] are superior to the ECG in the localization of the APs (84% vs. 76%). PMID:23967027

  8. Magnetization Transfer Magnetic Resonance Imaging Noninvasively Detects Renal Fibrosis in Swine Atherosclerotic Renal Artery Stenosis at 3.0 T.

    Science.gov (United States)

    Jiang, Kai; Ferguson, Christopher M; Woollard, John R; Zhu, Xiangyang; Lerman, Lilach O

    2017-11-01

    Renal fibrosis is a useful biomarker for diagnosis and evaluation of therapeutic interventions of renal diseases but often requires invasive testing. Magnetization transfer magnetic resonance imaging (MT-MRI), which evaluates the presence of macromolecules, offers a noninvasive tool to probe renal fibrosis in murine renal artery stenosis (RAS) at 16.4 T. In this study, we aimed to identify appropriate imaging parameters for collagen detection at 3.0 T MRI and to test the utility of MT-MRI in measuring renal fibrosis in a swine model of atherosclerotic RAS (ARAS). To select the appropriate offset frequency, an MT-MRI study was performed on a phantom containing 0% to 40% collagen I and III with offset frequencies from -1600 to +1600 Hz and other MT parameters empirically set as pulse width at 16 milliseconds and flip angle at 800 degrees. Then selected MT parameters were used in vivo on pigs 12 weeks after sham (n = 8) or RAS (n = 10) surgeries. The ARAS pigs were fed with high-cholesterol diet to induce atherosclerosis. The MT ratio (MTR) was compared with ex vivo renal fibrosis measured using Sirius-red staining. Offset frequencies at 600 and 1000 Hz were selected for collagen detection without direct saturation of free water signal, and subsequently applied in vivo. The ARAS kidneys showed mild cortical and medullary fibrosis by Sirius-red staining. The cortical and medullary MTRs at 600 and 1000 Hz were both increased. Renal fibrosis measured ex vivo showed good linear correlations with MTR at 600 (cortex: Pearson correlation coefficient r = 0.87, P 3.0 T. Therefore, MT-MRI may potentially be clinically applicable and useful for detection and monitoring of renal pathology in subjects with RAS.

  9. Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.

    Science.gov (United States)

    Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr

    2014-03-01

    In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Applicability of compton imaging in nuclear decommissioning activities

    International Nuclear Information System (INIS)

    Ljubenov, V.Lj.; Marinkovic, P.M.

    2002-01-01

    During the decommissioning of nuclear facilities significant part of the activities is related to the radiological characterization, waste classification and management. For these purposes a relatively new imaging technique, based on information from the gamma radiation that undergoes Compton scattering, is applicable. Compton imaging systems have a number of advantages for nuclear waste characterization, such as identifying hot spots in mixed waste in order to reduce the volume of high-level waste requiring extensive treatment or long-term storage, imaging large contaminated areas and objects etc. Compton imaging also has potential applications for monitoring of production, transport and storage of nuclear materials and components. This paper discusses some system design requirements and performance specifications for these applications. The advantages of Compton imaging are compared to competing imaging techniques. (author)

  11. 3-D spectral IP imaging: Non-invasive characterization of contaminant plumes. 1998 annual progress report

    International Nuclear Information System (INIS)

    Lesmes, D.; Morgan, F.D.; Rodi, W.

    1998-01-01

    annual SAGEEP conference (Shi et al., 1998). The authors have developed algorithms for forward modeling and inversion of spectral IP data in 3-D media. The algorithms accommodate a general earth model with a complex electrical conductivity as a function of frequency and 3-D spatial position. Using regularization and optimization techniques, the inversion algorithm obtains a 3-D image of resistivity amplitude and phase for each frequency contained in the data set. They have begun testing their algorithms on synthetic data generated from a simple model of a contaminant plume. The complex resistivity parameters of the background medium and plume are based on the laboratory results described above.'

  12. Using multimodal imaging techniques to monitor limb ischemia: a rapid noninvasive method for assessing extremity wounds

    Science.gov (United States)

    Luthra, Rajiv; Caruso, Joseph D.; Radowsky, Jason S.; Rodriguez, Maricela; Forsberg, Jonathan; Elster, Eric A.; Crane, Nicole J.

    2013-03-01

    Over 70% of military casualties resulting from the current conflicts sustain major extremity injuries. Of these the majority are caused by blasts from improvised explosive devices. The resulting injuries include traumatic amputations, open fractures, crush injuries, and acute vascular disruption. Critical tissue ischemia—the point at which ischemic tissues lose the capacity to recover—is therefore a major concern, as lack of blood flow to tissues rapidly leads to tissue deoxygenation and necrosis. If left undetected or unaddressed, a potentially salvageable limb may require more extensive debridement or, more commonly, amputation. Predicting wound outcome during the initial management of blast wounds remains a significant challenge, as wounds continue to "evolve" during the debridement process and our ability to assess wound viability remains subjectively based. Better means of identifying critical ischemia are needed. We developed a swine limb ischemia model in which two imaging modalities were combined to produce an objective and quantitative assessment of wound perfusion and tissue viability. By using 3 Charge-Coupled Device (3CCD) and Infrared (IR) cameras, both surface tissue oxygenation as well as overall limb perfusion could be depicted. We observed a change in mean 3CCD and IR values at peak ischemia and during reperfusion correlate well with clinically observed indicators for limb function and vitality. After correcting for baseline mean R-B values, the 3CCD values correlate with surface tissue oxygenation and the IR values with changes in perfusion. This study aims to not only increase fundamental understanding of the processes involved with limb ischemia and reperfusion, but also to develop tools to monitor overall limb perfusion and tissue oxygenation in a clinical setting. A rapid and objective diagnostic for extent of ischemic damage and overall limb viability could provide surgeons with a more accurate indication of tissue viability. This may

  13. Nuclear medicine imaging and data processing

    International Nuclear Information System (INIS)

    Bell, P.R.; Dillon, R.S.

    1978-01-01

    The Oak Ridge Imaging System (ORIS) is a software operating system structure around the Digital Equipment Corporation's PDP-8 minicomputer which provides a complete range of image manipulation procedures. Through its modular design it remains open-ended for easy expansion to meet future needs. Already included in the system are image access routines for use with the rectilinear scanner or gamma camera (both static and flow studies); display hardware design and corresponding software; archival storage provisions; and, most important, many image processing techniques. The image processing capabilities include image defect removal, smoothing, nonlinear bounding, preparation of functional images, and transaxial emission tomography reconstruction from a limited number of views

  14. A matter of collection and detection for intraoperative and noninvasive near-infrared fluorescence molecular imaging: To see or not to see?

    Science.gov (United States)

    Zhu, Banghe; Rasmussen, John C.; Sevick-Muraca, Eva M.

    2014-01-01

    Purpose: Although fluorescence molecular imaging is rapidly evolving as a new combinational drug/device technology platform for molecularly guided surgery and noninvasive imaging, there remains no performance standards for efficient translation of “first-in-humans” fluorescent imaging agents using these devices. Methods: The authors employed a stable, solid phantom designed to exaggerate the confounding effects of tissue light scattering and to mimic low concentrations (nM–pM) of near-infrared fluorescent dyes expected clinically for molecular imaging in order to evaluate and compare the commonly used charge coupled device (CCD) camera systems employed in preclinical studies and in human investigational studies. Results: The results show that intensified CCD systems offer greater contrast with larger signal-to-noise ratios in comparison to their unintensified CCD systems operated at clinically reasonable, subsecond acquisition times. Conclusions: Camera imaging performance could impact the success of future “first-in-humans” near-infrared fluorescence imaging agent studies. PMID:24506637

  15. The Nuclear Magnetic Resonance and its utilization in image formation

    International Nuclear Information System (INIS)

    Bonagamba, T.J.; Tannus, A.; Panepucci, H.

    1987-01-01

    Some aspects about Nuclear Magnetic Resonance (as Larmor Theorem, radio frequency pulse, relaxation of spins system) and its utilization in two dimensional image processing with the necessity of a tomography plane are studied. (C.G.C.) [pt

  16. FY08 Annual Report for Nuclear Resonance Fluorescence Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Glen A.; Caggiano, Joseph A.

    2009-01-06

    FY08 annual report for project the "Nuclear Resonance Fluorescence Imaging" project. Reviews accomplishments of last 3 years, including U-235 signature search, comparison of different photon sources, and examination of NRF measurements using monochromatic photon source.

  17. Non-invasive diagnostic method using the phase image for the Kent fiber position in Wolff-Parkinson-White (WPW) syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Makino, Katsutoshi; Ichikawa, Takehiko; Futagami, Yasuo; Hamada, Masayuki (Mie Univ., Tsu (Japan). School of Medicine)

    1983-10-01

    Gated blood pool scintigraphy with sup(99m)Tc-RBC was performed in patients with WPW syndrome and healthy controls. The contraction of the normal ventricle and the Kent fiber position in cases of WPW syndrome were observed on the phase image obtained by Fourier-transformation of the time activity curve. This method is considered to be more valuable than the other non-invasive procedures in cases of WPW syndrome, especially in the preoperative examination for transecting Kent fibers.

  18. Non-invasive in vivo imaging of arthritis in a collagen-induced murine model with phosphatidylserine-binding near-infrared (NIR) dye

    OpenAIRE

    Chan, Marion M; Gray, Brian D; Pak, Koon Y; Fong, Dunne

    2015-01-01

    Introduction Development of non-invasive molecular imaging techniques that are based on cellular changes in inflammation has been of active interest for arthritis diagnosis. This technology will allow real-time detection of tissue damage and facilitate earlier treatment of the disease, thus representing an improvement over X-rays, which detect bone damage at the advanced stage. Tracing apoptosis, an event occurring in inflammation, has been a strategy used. PSVue 794 is a low-molecular-weight...

  19. Noninvasive Imaging of Retinal Morphology and Microvasculature in Obese Mice Using Optical Coherence Tomography and Optical Microangiography

    Science.gov (United States)

    Zhi, Zhongwei; Chao, Jennifer R.; Wietecha, Tomasz; Hudkins, Kelly L.; Alpers, Charles E.; Wang, Ruikang K.

    2014-01-01

    Purpose. To evaluate early diabetes-induced changes in retinal thickness and microvasculature in a type 2 diabetic mouse model by using optical coherence tomography (OCT)/optical microangiography (OMAG). Methods. Twenty-two-week-old obese (OB) BTBR mice (n = 10) and wild-type (WT) control mice (n = 10) were imaged. Three-dimensional (3D) data volumes were captured with spectral domain OCT using an ultrahigh-sensitive OMAG scanning protocol for 3D volumetric angiography of the retina and dense A-scan protocol for measurement of the total retinal blood flow (RBF) rate. The thicknesses of the nerve fiber layer (NFL) and that of the NFL to the inner plexiform layer (IPL) were measured and compared between OB and WT mice. The linear capillary densities within intermediate and deep capillary layers were determined by the number of capillaries crossing a 500-μm line. The RBF rate was evaluated using an en face Doppler approach. These quantitative measurements were compared between OB and WT mice. Results. The retinal thickness of the NFL to IPL was significantly reduced in OB mice (P < 0.01) compared to that in WT mice, whereas the NFL thickness between the two was unchanged. 3D depth-resolved OMAG angiography revealed the first in vivo 3D model of mouse retinal microcirculation. Although no obvious differences in capillary vessel densities of the intermediate and deep capillary layers were detected between normal and OB mice, the total RBF rate was significantly lower (P < 0.05) in OB mice than in WT mice. Conclusions. We conclude that OB BTBR mice have significantly reduced NFL–IPL thicknesses and total RBF rates compared with those of WT mice, as imaged by OCT/OMAG. OMAG provides an unprecedented capability for high-resolution depth-resolved imaging of mouse retinal vessels and blood flow that may play a pivotal role in providing a noninvasive method for detecting early microvascular changes in patients with diabetic retinopathy. PMID:24458155

  20. A preclinical model for noninvasive imaging of hypoxia-induced gene expression; comparison with an exogenous marker of tumor hypoxia

    Energy Technology Data Exchange (ETDEWEB)

    Wen Bixiu; Burgman, Paul; Zanzonico, Pat; O' Donoghue, Joseph; Li, Gloria C.; Ling, C. Clifton [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics, New York (United States); Cai Shangde; Finn, Ron [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York (United States); Serganova, Inna [Memorial Sloan-Kettering Cancer Center, Department of Neurology, New York (United States); Blasberg, Ronald; Gelovani, Juri [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York (United States); Memorial Sloan-Kettering Cancer Center, Department of Neurology, New York (United States)

    2004-11-01

    Hypoxia is associated with tumor aggressiveness and is an important cause of resistance to radiation therapy and chemotherapy. Assays of tumor hypoxia could provide selection tools for hypoxia-modifying treatments. The purpose of this study was to develop and characterize a rodent tumor model with a reporter gene construct that would be transactivated by the hypoxia-inducible molecular switch, i.e., the upregulation of HIF-1. The reporter gene construct is the herpes simplex virus 1-thymidine kinase (HSV1-tk) fused with the enhanced green fluorescent protein (eGFP) under the regulation of an artificial hypoxia-responsive enhancer/promoter. In this model, tumor hypoxia would up-regulate HIF-1, and through the hypoxia-responsive promoter transactivate the HSV1-tkeGFPfusion gene. The expression of this reporter gene can be assessed with the {sup 124}I-labeled reporter substrate 2'-fluoro-2'-deoxy-1-{beta}-d-arabinofuranosyl-5-iodouracil ({sup 124}I-FIAU), which is phosphorylated by the HSV1-tk enzyme and trapped in the hypoxic cells. Animal positron emission tomography (microPET) and phosphor plate imaging (PPI) were used in this study to visualize the trapped {sup 124}I-FIAU, providing a distribution of the hypoxia-induced molecular events. The distribution of {sup 124}I-FIAU was also compared with that of an exogenous hypoxic cell marker, {sup 18}F-fluoromisonidazole (FMISO). Our results showed that {sup 124}I-FIAU microPET imaging of the hypoxia-induced reporter gene expression is feasible, and that the intratumoral distributions of {sup 124}I-FIAU and {sup 18}F-FMISO are similar. In tumor sections, detailed radioactivity distributions were obtained with PPI which also showed similarity between {sup 124}I-FIAU and {sup 18}F-FMISO. This reporter system is sufficiently sensitive to detect hypoxia-induced transcriptional activation by noninvasive imaging and might provide a valuable tool in studying tumor hypoxia and in validating existing and future

  1. 7-Tesla Magnetic Resonance Imaging Precisely and Noninvasively Reflects Inflammation and Remodeling of the Skeletal Muscle in a Mouse Model of Antisynthetase Syndrome

    Directory of Open Access Journals (Sweden)

    Clara Sciorati

    2014-01-01

    Full Text Available Inflammatory myopathies comprise heterogeneous disorders. Their etiopathogenesis is poorly understood, because of the paucity of informative experimental models and of approaches for the noninvasive study of inflamed tissues. Magnetic resonance imaging (MRI provides information about the state of the skeletal muscle that reflects various facets of inflammation and remodeling. This technique has been scarcely used in experimental models of inflammatory myopathies. We characterized the performance of MRI in a well-established mouse model of myositis and the antisynthetase syndrome, based on the immunization of wild-type mice with the amino-terminal fragment of histidyl-tRNA synthetase (HisRS. Over an eight-week period following myositis induction, MRI enabled precise identification of pathological events taking place in muscle tissue. Areas of edema and of active inflammation identified by histopathology paralleled muscle modifications detected noninvasively by MRI. Muscles changes were chronologically associated with the establishment of autoimmunity, as reflected by the development of anti-HisRS antibodies in the blood of immunized mice. MR imaging easily appreciated muscle damage and remodeling even if actual disruption of myofiber integrity (as assessed by serum concentrations of creatinine phosphokinase was limited. Thus, MR imaging represents an informative and noninvasive analytical tool for studying in vivo immune-mediated muscle involvement.

  2. 7-Tesla Magnetic Resonance Imaging Precisely and Noninvasively Reflects Inflammation and Remodeling of the Skeletal Muscle in a Mouse Model of Antisynthetase Syndrome

    Science.gov (United States)

    Sciorati, Clara; Esposito, Antonio; Campana, Lara; Canu, Tamara; Monno, Antonella; Palmisano, Anna; De Cobelli, Francesco; Del Maschio, Alessandro; Ascheman, Dana P.; Manfredi, Angelo A.; Rovere-Querini, Patrizia

    2014-01-01

    Inflammatory myopathies comprise heterogeneous disorders. Their etiopathogenesis is poorly understood, because of the paucity of informative experimental models and of approaches for the noninvasive study of inflamed tissues. Magnetic resonance imaging (MRI) provides information about the state of the skeletal muscle that reflects various facets of inflammation and remodeling. This technique has been scarcely used in experimental models of inflammatory myopathies. We characterized the performance of MRI in a well-established mouse model of myositis and the antisynthetase syndrome, based on the immunization of wild-type mice with the amino-terminal fragment of histidyl-tRNA synthetase (HisRS). Over an eight-week period following myositis induction, MRI enabled precise identification of pathological events taking place in muscle tissue. Areas of edema and of active inflammation identified by histopathology paralleled muscle modifications detected noninvasively by MRI. Muscles changes were chronologically associated with the establishment of autoimmunity, as reflected by the development of anti-HisRS antibodies in the blood of immunized mice. MR imaging easily appreciated muscle damage and remodeling even if actual disruption of myofiber integrity (as assessed by serum concentrations of creatinine phosphokinase) was limited. Thus, MR imaging represents an informative and noninvasive analytical tool for studying in vivo immune-mediated muscle involvement. PMID:24895622

  3. Threedimensional imaging of organ structures by nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Waters, W.; Smolorz, J.; Wellner, U.

    1985-01-01

    A simple method for threedimensional imaging of organ structures is presented. The method is based on a special acquisition mode in a nuclear resonance tomograph, exciting layers of 20 cm thickness at different angulations. The display is done by cinematography (which is usually used in nuclear cardiology) projecting the structures in a rotating movement. (orig.) [de

  4. Non-invasive mapping of bilateral motor speech areas using navigated transcranial magnetic stimulation and functional magnetic resonance imaging.

    Science.gov (United States)

    Könönen, Mervi; Tamsi, Niko; Säisänen, Laura; Kemppainen, Samuli; Määttä, Sara; Julkunen, Petro; Jutila, Leena; Äikiä, Marja; Kälviäinen, Reetta; Niskanen, Eini; Vanninen, Ritva; Karjalainen, Pasi; Mervaala, Esa

    2015-06-15

    Navigated transcranial magnetic stimulation (nTMS) is a modern precise method to activate and study cortical functions noninvasively. We hypothesized that a combination of nTMS and functional magnetic resonance imaging (fMRI) could clarify the localization of functional areas involved with motor control and production of speech. Navigated repetitive TMS (rTMS) with short bursts was used to map speech areas on both hemispheres by inducing speech disruption during number recitation tasks in healthy volunteers. Two experienced video reviewers, blinded to the stimulated area, graded each trial offline according to possible speech disruption. The locations of speech disrupting nTMS trials were overlaid with fMRI activations of word generation task. Speech disruptions were produced on both hemispheres by nTMS, though there were more disruptive stimulation sites on the left hemisphere. Grade of the disruptions varied from subjective sensation to mild objectively recognizable disruption up to total speech arrest. The distribution of locations in which speech disruptions could be elicited varied among individuals. On the left hemisphere the locations of disturbing rTMS bursts with reviewers' verification followed the areas of fMRI activation. Similar pattern was not observed on the right hemisphere. The reviewer-verified speech disruptions induced by nTMS provided clinically relevant information, and fMRI might explain further the function of the cortical area. nTMS and fMRI complement each other, and their combination should be advocated when assessing individual localization of speech network. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Reproducibility of non-invasive assessment of skin endothelial function using laser Doppler flowmetry and laser speckle contrast imaging.

    Directory of Open Access Journals (Sweden)

    Cyril Puissant

    Full Text Available Endothelial dysfunction precedes atherosclerosis. Vasodilation induced by acetylcholine (ACh is a specific test of endothelial function. Reproducibility of laser techniques such as laser-Doppler-flowmetry (LDF and Laser-speckle-contrast-imaging (LSCI to detect ACh vasodilation is debated and results expressions lack standardization. We aimed to study at a 7-day interval (i the inter-subject reproducibility, (ii the intra-subjects reproducibility, and (iii the effect of the results expressions over variability.Using LDF and LSCI simultaneously, we performed two different ACh-iontophoresis protocols. The maximal ACh vasodilation (peak-ACh was expressed as absolute or normalized flow or conductance values. Inter-subject reproducibility was expressed as coefficient of variation (inter-CV,%. Intra-subject reproducibility was expressed as within subject coefficients of variation (intra-CV,%, and intra-class correlation coefficients (ICC. Fifteen healthy subjects were included. The inter-subject reproducibility of peak-ACh depended upon the expression of the results and ranged from 55% to 162% for LDF and from 17% to 83% for LSCI. The intra-subject reproducibility (intra-CV/ICC of peak-ACh was reduced when assessed with LSCI compared to LDF no matter how the results were expressed and whatever the protocol used. The highest intra-subject reproducibility was found using LSCI. It was 18.7%/0.87 for a single current stimulation (expressed as cutaneous vascular conductance and 11.4%/0.61 for multiple current stimulations (expressed as absolute value.ACh-iontophoresis coupled with LSCI is a promising test to assess endothelial function because it is reproducible, safe, and non-invasive. N°: NCT01664572.

  6. Coded Aperture Nuclear Scintigraphy: A Novel Small Animal Imaging Technique

    Directory of Open Access Journals (Sweden)

    Dawid Schellingerhout

    2002-10-01

    Full Text Available We introduce and demonstrate the utility of coded aperture (CA nuclear scintigraphy for imaging small animals. CA imaging uses multiple pinholes in a carefully designed mask pattern, mounted on a conventional gamma camera. System performance was assessed using point sources and phantoms, while several animal experiments were performed to test the usefulness of the imaging system in vivo, with commonly used radiopharmaceuticals. The sensitivity of the CA system for 99mTc was 4.2 × 103 cps/Bq (9400 cpm/μCi, compared to 4.4 × 104 cps/Bq (990 cpm/μCi for a conventional collimator system. The system resolution was 1.7 mm, as compared to 4–6 mm for the conventional imaging system (using a high-sensitivity low-energy collimator. Animal imaging demonstrated artifact-free imaging with superior resolution and image quality compared to conventional collimator images in several mouse and rat models. We conclude that: (a CA imaging is a useful nuclear imaging technique for small animal imaging. The advantage in signal-to-noise can be traded to achieve higher resolution, decreased dose or reduced imaging time. (b CA imaging works best for images where activity is concentrated in small volumes; a low count outline may be better demonstrated using conventional collimator imaging. Thus, CA imaging should be viewed as a technique to complement rather than replace traditional nuclear imaging methods. (c CA hardware and software can be readily adapted to existing gamma cameras, making their implementation a relatively inexpensive retrofit to most systems.

  7. Imaging in hematology. Part 2: Computed tomography, magnetic resonance imaging and nuclear imaging

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    A dramatic increase of the role of imaging in diagnosis of blood diseases occurred with the development of computed tomography (CT) and magnetic resonance imaging (MRI). At present CT of the chest, abdomen, and pelvis is routinely employed in diagnostic and staging evaluation. The bone marrow may be imaged by one of several methods, including scintigraphy, CT and MRI. Nuclear imaging at diagnosis can clarify findings of uncertain significance on conventional staging and may be very useful in the setting of large masses to follow responses to therapy nad to evaluate the residual tumor in a large mass that has responded to treatment. Recent developments such as helical CT, single proton emission computed tomography (SPECT) and positron-emission tomography (PET) have continued to advance diagnosis and therapy

  8. Three dimensional nuclear magnetic resonance spectroscopic imaging of sodium ions using stochastic excitation and oscillating gradients

    International Nuclear Information System (INIS)

    Frederick, B.deB.

    1994-12-01

    Nuclear magnetic resonance (NMR) spectroscopic imaging of 23 Na holds promise as a non-invasive method of mapping Na + distributions, and for differentiating pools of Na + ions in biological tissues. However, due to NMR relaxation properties of 23 Na in vivo, a large fraction of Na + is not visible with conventional NMR imaging methods. An alternate imaging method, based on stochastic excitation and oscillating gradients, has been developed which is well adapted to measuring nuclei with short T 2 . Contemporary NMR imaging techniques have dead times of up to several hundred microseconds between excitation and sampling, comparable to the shortest in vivo 23 Na T 2 values, causing significant signal loss. An imaging strategy based on stochastic excitation has been developed which greatly reduces experiment dead time by reducing peak radiofrequency (RF) excitation power and using a novel RF circuit to speed probe recovery. Continuously oscillating gradients are used to eliminate transient eddy currents. Stochastic 1 H and 23 Na spectroscopic imaging experiments have been performed on a small animal system with dead times as low as 25μs, permitting spectroscopic imaging with 100% visibility in vivo. As an additional benefit, the encoding time for a 32x32x32 spectroscopic image is under 30 seconds. The development and analysis of stochastic NMR imaging has been hampered by limitations of the existing phase demodulation reconstruction technique. Three dimensional imaging was impractical due to reconstruction time, and design and analysis of proposed experiments was limited by the mathematical intractability of the reconstruction method. A new reconstruction method for stochastic NMR based on Fourier interpolation has been formulated combining the advantage of a several hundredfold reduction in reconstruction time with a straightforward mathematical form

  9. High-resolution harmonics ultrasound imaging for non-invasive characterization of wound healing in a pre-clinical swine model.

    Directory of Open Access Journals (Sweden)

    Surya C Gnyawali

    Full Text Available This work represents the first study employing non-invasive high-resolution harmonic ultrasound imaging to longitudinally characterize skin wound healing. Burn wounds (day 0-42, on the dorsum of a domestic Yorkshire white pig were studied non-invasively using tandem digital planimetry, laser speckle imaging and dual mode (B and Doppler ultrasound imaging. Wound depth, as measured by B-mode imaging, progressively increased until day 21 and decreased thereafter. Initially, blood flow at the wound edge increased up to day 14 and subsequently regressed to baseline levels by day 21, when the wound was more than 90% closed. Coinciding with regression of blood flow at the wound edge, there was an increase in blood flow in the wound bed. This was observed to regress by day 42. Such changes in wound angiogenesis were corroborated histologically. Gated Doppler imaging quantitated the pulse pressure of the primary feeder artery supplying the wound site. This pulse pressure markedly increased with a bimodal pattern following wounding connecting it to the induction of wound angiogenesis. Finally, ultrasound elastography measured tissue stiffness and visualized growth of new tissue over time. These studies have elegantly captured the physiological sequence of events during the process of wound healing, much of which is anticipated based on certain dynamics in play, to provide the framework for future studies on molecular mechanisms driving these processes. We conclude that the tandem use of non-invasive imaging technologies has the power to provide unprecedented insight into the dynamics of the healing skin tissue.

  10. Role of the multi-modality image archival and communication system in nuclear medicine

    International Nuclear Information System (INIS)

    Bela Kari; Adam Mester; Erno Mako; Zoltan Gyorfi; Bela Mihalik; Zsolt; Hegyi

    2004-01-01

    algorithm design. The complete PACS system with the Internet based telecommunication part according to the clinical requirements has been created and is continuously upgraded with the support and collaboration of three domestic companies. Currently 3 modalities - CT, nuclear medicine (NM), digitised mammography - are available and can be accessed in our institute from more than 15 workstations. Additionally, other extemal institutes -Dept. of Neurology, Dept. of Orthopaedics, 1st Surgical Clinic, Budapest University of Technology and Economics, Dept. of Measurement and Informatics System- are connected to our central archives and can access the necessary and/or available modalities for both routine clinical applications and research purposes according to the access rights rule. The created system works more than a year continuously under the described circumstances and participates intensively in the research (advisory systems for non-invasive studies), education, and daily clinical routine activities. Nowadays, the simultaneous presentation and post processing of the functional and morphological images plays more and more important role in order to make more reliable and quick clinical decision by non-invasive way (both functional and morphological modalities are developing very rapidly). This technology is outstandingly effective in the fields of consultation (even if it is combined by MMS), post processing and tele-evaluation as well as education. eRAD ImageMedical TM created in Palo Alto (USA, CA) a training real patient database with various digital radiological images in their PACS in order to learn and test the feasibility of the system. (authors)

  11. Noninvasive ventilation.

    Science.gov (United States)

    Rabatin, J T; Gay, P C

    1999-08-01

    Noninvasive ventilation refers to the delivery of assisted ventilatory support without the use of an endotracheal tube. Noninvasive positive pressure ventilation (NPPV) can be delivered by using a volume-controlled ventilator, a pressure-controlled ventilator, a bilevel positive airway pressure ventilator, or a continuous positive airway pressure device. During the past decade, there has been a resurgence in the use of noninvasive ventilation, fueled by advances in technology and clinical trials evaluating its use. Several manufacturers produce portable devices that are simple to operate. This review describes the equipment, techniques, and complications associated with NPPV and also the indications for both short-term and long-term applications. NPPV clearly represents an important addition to the techniques available to manage patients with respiratory failure. Future clinical trials evaluating its many clinical applications will help to define populations of patients most apt to benefit from this type of treatment.

  12. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    International Nuclear Information System (INIS)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-01-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease

  13. Noninvasive Multimodality Imaging of the Tumor Microenvironment: Registered Dynamic Magnetic Resonance Imaging and Positron Emission Tomography Studies of a Preclinical Tumor Model of Tumor Hypoxia

    Directory of Open Access Journals (Sweden)

    HyungJoon Cho

    2009-03-01

    Full Text Available In vivo knowledge of the spatial distribution of viable, necrotic, and hypoxic areas can provide prognostic information about the risk of developing metastases and regional radiation sensitivity and may be used potentially for localized dose escalation in radiation treatment. In this study, multimodality in vivo magnetic resonance imaging (MRI and positron emission tomography (PET imaging using stereotactic fiduciary markers in the Dunning R3327AT prostate tumor were performed, focusing on the relationship between dynamic contrast-enhanced (DCE MRI using Magnevist (Gd-DTPA and dynamic 18F-fluoromisonidazole (18F-Fmiso PET. The noninvasive measurements were verified using tumor tissue sections stained for hematoxylin/eosin and pimonidazole. To further validate the relationship between 18F-Fmiso and pimonidazole uptake, 18F digital autoradiography was performed on a selected tumor and compared with the corresponding pimonidazole-stained slices. The comparison of Akep values (kep = rate constant of movement of Gd-DTPA between the interstitial space and plasma and A = amplitude in the two-compartment model (Hoffmann U, Brix G, Knopp MV, Hess T and Lorenz WJ (1995. Magn Reson Med 33, 506– 514 derived from DCE-MRI studies and from early 18F-Fmiso uptake PET studies showed that tumor vasculature is a major determinant of early 18F-Fmiso uptake. A negative correlation between the spatial map of Akep and the slope map of late (last 1 hour of the dynamic PET scan 18F-Fmiso uptake was observed. The relationships between DCE-MRI and hematoxylin/eosin slices and between 18F-Fmiso PET and pimonidazole slices confirm the validity of MRI/PET measurements to image the tumor microenvironment and to identify regions of tumor necrosis, hypoxia, and well-perfused tissue.

  14. Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT.

    Science.gov (United States)

    Komar, Gaber; Oikonen, Vesa; Sipilä, Hannu; Seppänen, Marko; Minn, Heikki

    2012-11-01

    The aim of this study was to develop a simple noninvasive method for measuring blood flow using [15O]H2O PET/CT for the head and neck area applicable in daily clinical practice. Fifteen dynamic [15O]H2O PET emission scans with simultaneous online radioactivity measurements of radial arterial blood [Blood-input functions (IFs)] were performed. Two noninvasively obtained population-based input functions were calculated by averaging all Blood-IF curves corrected for patients' body mass and injected dose [standardized uptake value (SUV)-IF] and for body surface area (BSA-IF) and injected dose. Parametric perfusion images were calculated for each set of IFs using a linearized two-compartment model, and values for several tissues were compared using Blood-IF as the gold standard. On comparing all tissues, the correlation between blood flow obtained with the invasive Blood-IF and both SUV-IF and BSA-IF was significant (R2=0.785 with P<0.001 and R2=0.813 with P<0.001, respectively). In individual tissues, the performance of the two noninvasive methods was most reliable in resting muscle and slightly less reliable in tumour and cerebellar regions. In these two tissues, only BSA-IF showed a significant correlation with Blood-IF (R2=0.307 with P=0.032 in tumours and R2=0.398 with P<0.007 in the cerebellum). The BSA-based noninvasive method enables clinically relevant delineation between areas of low and high blood flow in tumours. The blood flow of low-perfusion tissues can be reliably quantified using either of the evaluated noninvasive methods.

  15. Principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Pykett, I.L.; Newhouse, J.H.; Buonanno, F.S.; Brady, T.J.; Goldman, M.R.; Kistler, J.P.; Pohost, G.M.

    1982-01-01

    The physical principles which underlie the phenomenon of nuclear magnetic resonance (NMR) are presented in this primer. The major scanning methods are reviewed, and the principles of technique are discussed. A glossary of NMR terms is included

  16. Medical imaging. From nuclear medicine to neuro-sciences

    International Nuclear Information System (INIS)

    2003-03-01

    Nuclear medicine and functional imaging were born of the CEA's ambition to promote and develop nuclear applications in the fields of biology and health. Nuclear medicine is based on the use of radioactive isotopes for diagnostic and therapeutic purposes. It could never have developed so rapidly without the progress made in atomic and nuclear physics. One major breakthrough was the discovery of artificial radioelements by Irene and Frederic Joliot in 1934, when a short-lived radioactive isotope was created for the first time ever. Whether natural or synthetic, isotopes possess the same chemical properties as their non-radioactive counterparts. The only difference is that they are unstable and this instability causes disintegration, leading to radiation emission. All we need are suitable detection tools to keep track of them. 'The discovery of artificial radioelements is at the root of the most advanced medical imaging techniques'. The notion of tracer dates back to 1913. Invented by George de Hevesy, it lies at the root of nuclear medicine. By discovering how to produce radioactive isotopes, Irene and Frederic Joliot provided biology researchers with nuclear tools of unrivalled efficiency. Today, nuclear medicine and functional imaging are the only techniques capable of giving us extremely precise information about living organisms in a non-traumatic manner and without upsetting their balance. Positron emission tomography (PET) and nuclear magnetic resonance imaging (MRI) are the main imaging techniques used at the CEA in its neuro-imaging research activities. These techniques are now developing rapidly and becoming increasingly important not only in the neuroscience world, but also for innovative therapies and cancer treatment. (authors)

  17. (New imaging systems in nuclear medicine)

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    Further progress has been made on improving the uniformity and stability of PCR-I, the single ring analog coded tomograph. This camera has been employed in a wide range of animal studies described below. Data from PCR-I have been used in various image processing procedures. These include motion pictures of dog heart, comparison of PET and MRI image in dog heart and rat brain and quantitation of tumor metabolism in the nude mouse using blood data from heart images. A SUN workstation with TAAC board has been used to produce gated three-dimensional images of the dog heart. The ANALYZE program from the Mayo Clinic has also been mounted on a SUN workstation for comparison of images and image processing. 15 refs., 6 figs.

  18. [New imaging systems in nuclear medicine

    International Nuclear Information System (INIS)

    1990-01-01

    Further progress has been made on improving the uniformity and stability of PCR-I, the single ring analog coded tomograph. This camera has been employed in a wide range of animal studies described below. Data from PCR-I have been used in various image processing procedures. These include motion pictures of dog heart, comparison of PET and MRI image in dog heart and rat brain and quantitation of tumor metabolism in the nude mouse using blood data from heart images. A SUN workstation with TAAC board has been used to produce gated three-dimensional images of the dog heart. The ANALYZE program from the Mayo Clinic has also been mounted on a SUN workstation for comparison of images and image processing. 15 refs., 6 figs

  19. Nuclear medicine imaging in podiatric disorders

    International Nuclear Information System (INIS)

    Karl, R.D. Jr.; Hammes, C.S.

    1988-01-01

    Radionuclide scanning is a valuable diagnostic tool based on metabolic and anatomic imaging. When used in the appropriate clinical setting, radionuclide imaging is a sensitive, minimally invasive imaging modality that detects and differentiates skeletal from nonskeletal pathology in the painful foot. Isotopic scanning is of particular value in the evaluation of the diabetic foot and in the subsequent follow-up of response to therapy.72 references

  20. Basic principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Valk, J.; MacLean, C.; Algra, P.R.

    1985-01-01

    The intent of this book is to help clinicians understand the basic physical principles of magnetic resonance (MR) imaging. The book consists of the following: a discussion of elementary considerations; pulse sequencing; localization of MR signals in space; MR equipment; MR contrast agents; clinical applications; MR spectroscopy; and biological effects of MR imaging; a set of appendixes; and a bibliography. Illustrations and images are included

  1. Display of cross sectional anatomy by nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hinshaw, W.S.; Andrew, E.R.; Bottomley, P.A.; Holland, G.N.; Moore, W.S.; Worthington, B.S.

    1978-01-01

    High definition cross-sectional images produced by a new nuclear magnetic resonace (NMR) technique are shown. The images are a series of thin section scans in the coronal plane of the head of a rabbit. The NMR images are derived from the distribution of the density of mobile hydrogen atoms. Various tissue types can be distinguished and a clear registration of gross anatomy is demonstrated. No known hazards are associated with the technique. (author)

  2. Nuclear magnetic resonance imaging and brain functional exploration

    International Nuclear Information System (INIS)

    Le Bihan, D.; CEA, 91 - Orsay

    1997-01-01

    The utilization of nuclear magnetic resonance imaging for functional analysis of the brain is presented: the oxygenated and deoxygenated blood flowing in the brain do not have the same effect on NMR images; the oxygenated blood, related to brain activity, may be detected and the corresponding activity zone in the brain, identified; functional NMR imaging could be used to gain a better understanding of functional troubles linked to neurological or psychiatric diseases

  3. Display of cross sectional anatomy by nuclear magnetic resonance imaging.

    Science.gov (United States)

    Hinshaw, W S; Andrew, E R; Bottomley, P A; Holland, G N; Moore, W S

    1978-04-01

    High definition cross-sectional images produced by a new nuclear magnetic resonance (NMR) technique are shown. The images are a series of thin section scans in the coronal plane of the head of a rabbit. The NMR images are derived from the distribution of the density of mobile hydrogen atoms. Various tissue types can be distinguished and a clear registration of gross anatomy is demonstrated. No known hazards are associated with the technique.

  4. Electronics Related to Nuclear Medicine Imaging Devices. Chapter 7

    Energy Technology Data Exchange (ETDEWEB)

    Ott, R. J. [Joint Department of Physics, Royal Marsden Hospital and Institute of Cancer Research, Surrey (United Kingdom); Stephenson, R. [Rutherford Appleton Laboratory, Oxfordshire (United Kingdom)

    2014-12-15

    Nuclear medicine imaging is generally based on the detection of X rays and γ rays emitted by radionuclides injected into a patient. In the previous chapter, the methods used to detect these photons were described, based most commonly on a scintillation counter although there are imaging devices that use either gas filled ionization detectors or semiconductors. Whatever device is used, nuclear medicine images are produced from a very limited number of photons, due mainly to the level of radioactivity that can be safely injected into a patient. Hence, nuclear medicine images are usually made from many orders of magnitude fewer photons than X ray computed tomography (CT) images, for example. However, as the information produced is essentially functional in nature compared to the anatomical detail of CT, the apparently poorer image quality is overcome by the nature of the information produced. The low levels of photons detected in nuclear medicine means that photon counting can be performed. Here each photon is detected and analysed individually, which is especially valuable, for example, in enabling scattered photons to be rejected. This is in contrast to X ray imaging where images are produced by integrating the flux entering the detectors. Photon counting, however, places a heavy burden on the electronics used for nuclear medicine imaging in terms of electronic noise and stability. This chapter will discuss how the signals produced in the primary photon detection process can be converted into pulses providing spatial, energy and timing information, and how this information is used to produce both qualitative and quantitative images.

  5. Method for nuclear magnetic resonance imaging

    Science.gov (United States)

    Kehayias, J.J.; Joel, D.D.; Adams, W.H.; Stein, H.L.

    1988-05-26

    A method for in vivo NMR imaging of the blood vessels and organs of a patient characterized by using a dark dye-like imaging substance consisting essentially of a stable, high-purity concentration of D/sub 2/O in a solution with water.

  6. Three dimensional imaging in cardiac nuclear medicine

    International Nuclear Information System (INIS)

    Torizuka, Kanji; Ishii, Yasushi; Yonekura, Yoshiharu; Yamamoto, Kazutaka; Tamaki, Takeyoshi

    1981-01-01

    Methods to obtain three dimensional images of the heart were reviewed. Gated three dimensional display reconstructed from images using bidirectional collimator, was a useful method to detect akinesis of the heart wall. Tomographic observation of the heart can be carried out by a pinhole collimator to image ischemia with high sensitivity. However the focusing plane must be carefully selected to prevent false positives. In the case of emission CT (ECT), utilization of positron emitters gave a quantitative image without correction, whereas single photon ECT needed the correction due to the absorption of γ-ray. Though the reliability of the images by ECT was high, the time required for data acquisition was much longer than that by a 7 pinhole or bidirectional collimator. (Nakanishi, T.)

  7. Noninvasive imaging of alphaVbeta3 function as a predictor of the antimigratory and antiproliferative effects of dasatinib.

    Science.gov (United States)

    Dumont, Rebecca A; Hildebrandt, Isabel; Su, Helen; Haubner, Roland; Reischl, Gerald; Czernin, Johannes G; Mischel, Paul S; Weber, Wolfgang A

    2009-04-01

    Src family kinases (SFKs) are commonly deregulated in cancer cells. Among other functions, SFKs are critical for cellular migration and invasion. SFK inhibitors are being studied as targeted cancer drugs, but there are no biomarkers for noninvasive assessment of SFK inhibition. The aim of this study was to evaluate whether imaging of alpha(V)beta(3) integrin activity with positron emission tomography (PET) and [(64)Cu]DOTA-cyclo-(Arg-Gly-Asp-dPhe-Lys) {[(64)Cu]DOTA-c(RGDfK)} can be used for monitoring response to the SFK inhibitor dasatinib. Severe combined immunodeficient mice bearing U87MG xenografts were gavaged daily over 72 hours with 72 or 95 mg/kg of dasatinib or vehicle. Tumor uptake of [(64)Cu]DOTA-c(RGDfK) was measured by small-animal PET. In parallel, fluorodeoxyglucose (FDG) scans were performed to assess tumor metabolism in response to dasatinib treatment. Dasatinib significantly (P<0.0001) reduced [(64)Cu]DOTA-c(RGDfK) uptake by up to 59% in U87MG xenografts [2.10+/-0.14% injected dose/gram (ID/g) in the 95 mg/kg group and 3.12+/-0.18% ID/g in the 72 mg/kg group, versus 5.08+/-0.80% ID/g in controls]. In contrast, tumor FDG uptake showed no significant reduction with dasatinib therapy (8.13+/-0.45% ID/g in treated versus 10.39+/-1.04% ID/g in controls; P=0.170). Histologically, tumors were viable at the time of the follow-up PET scan but showed inhibition of focal adhesion kinase. Continued dasatinib treatment resulted in a significant inhibition of tumor growth (tumor size on day 10 of therapy: 21.13+/-2.60 mm(2) in treated animals versus 122.50+/-17.68 mm(2) in controls; P=0.001). [(64)Cu]DOTA-c(RGDfK) may provide a sensitive means of monitoring tumor response to SFK inhibition in alpha(V)beta(3)-expressing cancers early in the course of therapy.

  8. Progress in molecular nuclear medicine imaging of pancreatic beta cells

    International Nuclear Information System (INIS)

    Wu Haifei; Yin Hongyan; Liu Shuai; Zhang Yifan

    2010-01-01

    Diabetes mellitus is a common and frequently occurring disease which seriously threaten the health of human beings. Type 1 and type 2 diabetes respectively results from being destroyed and insufficient beta-cell mass. The associated symptoms appear until 50%-60% decrease of beta-cell mass. Because pancreas is deeply located in the body, with few beta-cell mass, the current methods of clinical diagnosis are invasive and late. So diagnosis of metabolism disease of beta-cell early non-invasively becomes more and more popular, imaging diagnosis of diabetes mellitus becomes the focus of researches, but how to estimate the mass of beta-cell still an important subject in imaging technology. (authors)

  9. Recycling and imaging of nuclear singlet hyperpolarization

    DEFF Research Database (Denmark)

    Pileio, Giuseppe; Bowen, Sean; Laustsen, Christoffer

    2013-01-01

    observation of the same batch of polarized nuclei over a period of 30 min and more. We report a recycling protocol in which the enhanced nuclear polarization achieved by dissolution-DNP is observed with full intensity and then returned to singlet order. MRI experiments may be run on a portion of the available...

  10. The three public images of nuclear power

    International Nuclear Information System (INIS)

    Gritti, Jules

    1982-01-01

    The author outlines the three main fears which, to his mind, have stemmed from the nuclear power question over the three post-war decades and marked public opinion to a greater or lesser extent: fear of the atom bomb, fear of cancer, fear of pollution [fr

  11. Nuclear imaging technology and global requirements

    International Nuclear Information System (INIS)

    Lele, R.D.

    1991-01-01

    After a brief review of the present state of availability of nuclear medicine services in the countries of world, a mention has been made of WHO programme on nuclear medicine. Nuclear medicine services in the developing countries are dependent on the availability of appropriate instrumentation and radiopharmaceuticals at affordable costs and existence of basic infrastructure required for giving such services. Basic infrastructure requirements are stable power supplies, air-conditioning systems, preventive maintenance and repair facilities. These are discussed. It is pointed out that the use of rectilinear scanners with 113m In instead of costly gamma cameras is still relevant in the third world countries. Need to develop a too low-cost gamma camera is emphasized. Electronics Corporation of India Ltd has plans to manufacture such cameras. Design of this camera is described. Foreign collaboration or technology transfer through concerned governement department needs to be explored so that the benefits of nuclear medicine can be brought to the third world countries by 2000 AD. (M.G.B.). 2 tabs

  12. Imaging of Nuclear Fragmentation in Nuclear Track Emulsion Relativistic Nuclei

    International Nuclear Information System (INIS)

    Zarubina, I.G. JINR

    2011-01-01

    The method of nuclear track emulsion provides a uniquely complete observation of multiple fragment systems produced in dissociation of relativistic nuclei. The most valuable events of coherent dissociation of nuclei in narrow jets of light and the lightest nuclei with a net charge as in the initial nucleus, occurring without the production of fragments of the target nuclei and mesons (the so-called w hite s tars), comprise a few percent among the observed interactions. The data on this phenomenon are fragmented, and the interpretation is not offered. The dissociation degree of light O, Ne, Mg and Si, and as well as heavy Au, Pb and U nuclei may reach a complete destruction to light and the lightest nuclei and nucleons, resulting in cluster systems of an unprecedented complexity. Studies with relativistic neutron-deficient nuclei have special advantages due to more complete observations. An extensive collection of macro videos of such interactions in nuclear track emulsion gathered by the Becquerel collaboration is presented

  13. Image sequence analysis in nuclear medicine: (1) Parametric imaging using statistical modelling

    International Nuclear Information System (INIS)

    Liehn, J.C.; Hannequin, P.; Valeyre, J.

    1989-01-01

    This is a review of parametric imaging methods on Nuclear Medicine. A Parametric Image is an image in which each pixel value is a function of the value of the same pixel of an image sequence. The Local Model Method is the fitting of each pixel time activity curve by a model which parameter values form the Parametric Images. The Global Model Method is the modelling of the changes between two images. It is applied to image comparison. For both methods, the different models, the identification criterion, the optimization methods and the statistical properties of the images are discussed. The analysis of one or more Parametric Images is performed using 1D or 2D histograms. The statistically significant Parametric Images, (Images of significant Variances, Amplitudes and Differences) are also proposed [fr

  14. Nuclear Fuel Assembly Assessment Project and Image Categorization

    Energy Technology Data Exchange (ETDEWEB)

    Lindsey, C.S.; Lindblad, T.; Waldemark, K. [Royal Inst. of Tech., Stockholm (Sweden); Hildingsson, Lars [Swedish Nuclear Power Inspectorate, Stockholm (Sweden)

    1998-07-01

    A project has been underway to add digital imaging and processing to the inspection of nuclear fuel by the International Atomic Energy Agency. The ultimate goals are to provide the inspector not only with the advantages of Ccd imaging, such as high sensitivity and digital image enhancements, but also with an intelligent agent that can analyze the images and provide useful information about the fuel assemblies in real time. The project is still in the early stages and several interesting sub-projects have been inspired. Here we give first a review of the work on the fuel assembly image analysis and then give a brief status report on one of these sub-projects that concerns automatic categorization of fuel assembly images. The technique could be of benefit to the general challenge of image categorization

  15. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.; Tsui, B.

    1981-01-01

    A general computer code to simulate the imaging properties of existing and hypothetical imaging systems viewing realistic source distributions within non-uniform media. Such a code allows comparative evaluations of existing and hypothetical systems, and optimization of critical parameters of system design by maximizing the signal-to-noise ratio. To be most useful, such a code allows simulation of conventional scintillation scanners and cameras as well as single-photon and position tomographic systems

  16. Noninvasive near-infrared live imaging of human adult mesenchymal stem cells transplanted in a rodent model of Parkinson’s disease

    Directory of Open Access Journals (Sweden)

    Bossolasco P

    2012-01-01

    Full Text Available P Bossolasco1,*, L Cova2,*, G Levandis3, V Diana2, S Cerri3, G Lambertenghi Deliliers1, E Polli1, V Silani2,4, F Blandini3, MT Armentero31Fondazione Matarelli, Dipartimento di Farmacologia, Chemioterapia e Tossicologia Medica, Università degli Studi di Milano, Milan, 2Department of Neurology and Laboratory of Neuroscience-IRCCS Istituto Auxologico Italiano, Cusano Milanino, 3Laboratory of Functional Neurochemistry, Interdepartmental Research Centre for Parkinson’s Disease, IRCCS National Institute of Neurology “C Mondino”, Pavia, 4Department of Neurology and Laboratory of Neuroscience, Centro “Dino Ferrari” Università degli Studi di Milano-IRCCS Istituto Auxologico Italiano, Milan, Italy *These authors contributed equally to this workBackground: We have previously shown that human mesenchymal stem cells (hMSCs can reduce toxin-induced neurodegeneration in a well characterized rodent model of Parkinson’s disease. However, the precise mechanisms, optimal cell concentration required for neuroprotection, and detailed cell tracking need to be defined. We exploited a near-infrared imaging platform to perform noninvasive tracing following transplantation of tagged hMSCs in live parkinsonian rats.Methods: hMSCs were labeled both with a membrane intercalating dye, emitting in the near-infrared 815 nm spectrum, and the nuclear counterstain, Hoechst 33258. Effects of near-infrared dye on cell metabolism and proliferation were extensively evaluated in vitro. Tagged hMSCs were then administered to parkinsonian rats bearing a 6-hydroxydopamine-induced lesion of the nigrostriatal pathway, via two alternative routes, ie, intrastriatal or intranasal, and the cells were tracked in vivo and ex vivo using near-infrared technology.Results: In vitro, NIR815 staining was stable in long-term hMSC cultures and did not interfere with cell metabolism or proliferation. A significant near-infrared signal was detectable in vivo, confined around the injection

  17. The molecular imaging approach to image infections and inflammation by nuclear medicine techniques

    NARCIS (Netherlands)

    Signore, Alberto; Glaudemans, Andor W. J. M.

    2011-01-01

    Inflammatory and infectious diseases are a heterogeneous class of diseases that may be divided into infections, acute inflammation and chronic inflammation. Radiological imaging techniques have, with the exception of functional MRI, high sensitivity but lack in specificity. Nuclear medicine

  18. Susceptibility effects in nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ziener, Christian Herbert

    2008-01-01

    The properties of dephasing and the resulting relaxation of the magnetization are the basic principle on which all magnetic resonance imaging methods are based. The signal obtained from the gyrating spins is essentially determined by the properties of the considered tissue. Especially the susceptibility differences caused by magnetized materials (for example, deoxygenated blood, BOLD-effect) or magnetic nanoparticles are becoming more important for biomedical imaging. In the present work, the influence of such field inhomogeneities on the NMR-signal is analyzed. (orig.)

  19. Exclusion and diagnosis of pulmonary embolism by a rapid ELISA D-dimer test and noninvasive imaging techniques within the context of a clinical model.

    Science.gov (United States)

    Michiels, J J; Pattynama, P M

    2000-01-01

    A negative rapid ELISA D-dimer test alone in out-patients with a low to moderate clinical probability (CP) on pulmonary embolism (PE) is predicted to safely exclude pulmonary embolism. The combination of a negative rapid ELISA D-dimer test and a low to moderate CP on PE followed by compression ultrasonography (CUS) for the detection of deep vein thrombosis (DVT) is safe and cost-effective as it reduces the need for noninvasive imaging techniques to about 50% to 60% of outpatients with suspected PE. A high probability ventilation-perfusion (VP) scan or a positive spiral CT consistent with PE and the detection of DVT by CUS are currently considered to be clear indications for anticoagulant treatment. Subsequent pulmonary angiography (PA) is the gold standard diagnostic strategy to exclude or diagnose PE in suspected outpatients with a negative CUS, a positive rapid ELISA D-dimer test, and a nondiagnostic VP scan or negative spiral CT to prevent overtreatment with anticoagulants. However, the willingness of clinicians and the availability of resources to perform PA is restricted, a fact that has provided an impetus for clinical investigators to search for alternative noninvasive strategies to exclude or detect venous thromboembolism (VTE). Serial CUS testing for the detection of DVT in patients with a low to moderate CP on PE and a nondiagnostic VP scan or negative spiral CT is predicted to be safe and will reduce the need for PA to less than 10% or even less than 5%. This noninvasive serial CUS strategy restricts the need for invasive PA to a minor group of patients (spiral CT and a high CP on PE. Prospective evaluations are warranted to implement and to validate the advantages and the disadvantages of the various combinations of noninvasive strategies and to compare serial CUS testing versus PA in randomized clinical management studies of outpatients with suspected pulmonary embolism.

  20. Noninvasive determination of myocardial blood flow, oxygen consumption and efficiency in normal humans by carbon-11 acetate positron emission tomography imaging

    International Nuclear Information System (INIS)

    Porenta, G.; Cherry, S.; Czernin, J.; Brunken, R.; Kuhle, W.; Hashimoto, T.; Schelbert, H.R.

    1999-01-01

    The aims of this study were: (1) to measure noninvasively and near simultaneously myocardial blood flow, oxygen consumption, and contractile function and (2) to analyze myocardial energy expenditure and efficiency at rest and during dobutamine stress in normal humans. Dynamic and gated carbon-11 acetate positron emission tomography (PET) imaging was performed in 11 normal subjects. The initial uptake of 11 C-acetate was measured to estimate myocardial blood flow. Oxygen consumption was derived from the monoexponential slope of the 11 C-clearance curve recorded during myocardial washout. ECG-gated systolic and diastolic images were acquired during the peak myocardial 11 C activity to measure left ventricular radius, myocardial wall thickness, and long axis length. Myocardial oxygen consumption and parameters of cardiac geometry were used to determine myocardial energetics and cardiac efficiency by tension-area area analysis. Myocardial blood flow averaged 0.8±0.06 ml min -1 g -1 at rest and 1.48±0.15 ml min -1 g -1 during dobutamine stress. Oxygen delivery and consumption were 151±13 and 88±15 μl O 2 min -1 g -1 at rest and increased to 291±31 and 216±31 μl O 2 min -1 g -1 , respectively, during pharmacological stress (P 11 C acetate imaging provides the unique capability to study noninvasively determinants of myocardial energy delivery, expenditure, and efficiency. (orig.)

  1. A Preclinical Evaluation of Antrodia camphorata Alcohol Extracts in the Treatment of Non-Small Cell Lung Cancer Using Non-Invasive Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Jeng-Feng Chiou

    2011-01-01

    Full Text Available This study was carried out to provide a platform for the pre-clinical evaluation of anti-cancer properties of a unique CAM (complementary and alternative medicine agent, Antrodia camphorata alcohol extract (ACAE, in a mouse model with the advantageous non-invasive in vivo bioluminescence molecular imaging technology. In vitro analyses on the proliferation, migration/invasion, cell cycle and apoptosis were performed on ACAE-treated non-small cell lung cancer cells, H441GL and control CGL1 cells. In vivo, immune-deficient mice were inoculated subcutaneously with H441GL followed by oral gavages of ACAE. The effect of ACAE on tumor progression was monitored by non-invasive bioluminescence imaging. The proliferation and migration/invasion of H441GL cells were inhibited by ACAE in a dose-dependent manner. In addition, ACAE induced cell cycle arrest at G0/G1 phase and apoptosis in H441GL cells as shown by flow cytometric analysis, Annexin-V immunoflourescence and DNA fragmentation. In vivo bioluminescence imaging revealed that tumorigenesis was significantly retarded by oral treatment of ACAE in a dose-dependent fashion. Based on our experimental data, ACAE contains anti-cancer properties and could be considered as a potential CAM agent in future clinical evaluation.

  2. Non-invasive diagnostic method using the phase image for the Kent fiber position in Wolff-Parkinson-White (WPW) syndrome

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Makino, Katsutoshi; Ichikawa, Takehiko; Futagami, Yasuo; Hamada, Masayuki

    1983-01-01

    Gated blood pool scintigraphy with sup(99m)Tc-RBC was performed in patients with WPW syndrome and healthy controls. The contraction of the normal ventricle and the Kent fiber position in cases of WPW syndrome were observed on the phase image obtained by Fourier-transformation of the time activity curve. This method is considered to be more valuable than the other non-invasive procedures in cases of WPW syndrome, especially in the preoperative examination for transecting Kent fibers. (Namekawa, K.)

  3. Nuclear medicine and radiologic imaging in sports injuries

    Energy Technology Data Exchange (ETDEWEB)

    Glaudermans, Andor W.J.M. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Gielen, Jan L.M.A. [Antwerp Univ. Hospital, Edegem (Belgium). Dept. of Radiology; Antwerp Univ. Hospital, Edegem (Belgium). Dept. of Sports Medicine; Antwerp Univ. Hospital, Edegem (Belgium). Dept. of Medicine; Zwerver, Johannes (ed.) [Groningen Univ. (Netherlands). Center for Sports Medicine

    2015-10-01

    This comprehensive book describes in detail how nuclear medicine and radiology can meet the needs of the sports medicine physician by assisting in precise diagnosis, clarification of pathophysiology, imaging of treatment outcome and monitoring of rehabilitation. Individual sections focus on nuclear medicine and radiologic imaging of injuries to the head and face, spine, chest, shoulder, elbow and forearm, wrist and hand, pelvic region, knee, lower leg, ankle and foot. The pathophysiology of sports injuries frequently encountered in different regions of the body is described from the perspective of each specialty, and the potential diagnostic and management benefits offered by the new hybrid imaging modalities - SPECT/CT, PET/CT, and PET/MRI - are explained. In addition, a range of basic and general issues are addressed, including imaging of the injuries characteristic of specific sports. It is hoped that this book will promote interdisciplinary awareness and communication and improve the management of injured recreational or elite athletes.

  4. Restoration and functional analysis of nuclear medicine images

    International Nuclear Information System (INIS)

    Wendt, R.E. III.

    1982-01-01

    The nuclear medicine physician uses visual interpretation of a movie-like display of the beating human heart to detect wall motion abnormalities which might be related to impaired cardiac function. The present work is directed toward extracting more information from the heart motion study, and presenting it in a useful manner. A spatially adaptive smoothing routine using a quadtree image representation gives an improvement in mean squared error compared to the S9 smoother commonly used for nuclear medicine studies. Functional images show the two-dimensional distribution of parameters of the heart motion. The most popular, the first harmonic phase functional image, formed from the first Fourier harmonic fit to each pixel time-activity curve, is subject to significant artifacts which make a simple interpretation of it difficult. A multi-harmonic approximation is more accurate and offers a wealth of unique parameters with which to construct more directly meaningful functional images

  5. Nuclear medicine and radiologic imaging in sports injuries

    International Nuclear Information System (INIS)

    Glaudermans, Andor W.J.M.; Gielen, Jan L.M.A.; Antwerp Univ. Hospital, Edegem; Antwerp Univ. Hospital, Edegem; Zwerver, Johannes

    2015-01-01

    This comprehensive book describes in detail how nuclear medicine and radiology can meet the needs of the sports medicine physician by assisting in precise diagnosis, clarification of pathophysiology, imaging of treatment outcome and monitoring of rehabilitation. Individual sections focus on nuclear medicine and radiologic imaging of injuries to the head and face, spine, chest, shoulder, elbow and forearm, wrist and hand, pelvic region, knee, lower leg, ankle and foot. The pathophysiology of sports injuries frequently encountered in different regions of the body is described from the perspective of each specialty, and the potential diagnostic and management benefits offered by the new hybrid imaging modalities - SPECT/CT, PET/CT, and PET/MRI - are explained. In addition, a range of basic and general issues are addressed, including imaging of the injuries characteristic of specific sports. It is hoped that this book will promote interdisciplinary awareness and communication and improve the management of injured recreational or elite athletes.

  6. Nuclear transverse sectional brain function imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1978-01-01

    A transverse radionuclide scanfield imaging apparatus is described comprising a plurality of highly focused closely laterally adjacent collimators arranged inwardly focused in an array which surrounds a scan field, each collimator being moveable relative to its adjacent collimator; and means for imparting travel to the collimators such that the focal point of each collimator uniformly samples at least one half of the scan field

  7. Passive 3D imaging of nuclear waste containers with Muon Scattering Tomography

    Science.gov (United States)

    Thomay, C.; Velthuis, J.; Poffley, T.; Baesso, P.; Cussans, D.; Frazão, L.

    2016-03-01

    The non-invasive imaging of dense objects is of particular interest in the context of nuclear waste management, where it is important to know the contents of waste containers without opening them. Using Muon Scattering Tomography (MST), it is possible to obtain a detailed 3D image of the contents of a waste container on reasonable timescales, showing both the high and low density materials inside. We show the performance of such a method on a Monte Carlo simulation of a dummy waste drum object containing objects of different shapes and materials. The simulation has been tuned with our MST prototype detector performance. In particular, we show that both a tungsten penny of 2 cm radius and 1 cm thickness, and a uranium sheet of 0.5 cm thickness can be clearly identified. We also show the performance of a novel edge finding technique, by which the edges of embedded objects can be identified more precisely than by solely using the imaging method.

  8. Accuracy and Precision of Radioactivity Quantification in Nuclear Medicine Images

    Science.gov (United States)

    Frey, Eric C.; Humm, John L.; Ljungberg, Michael

    2012-01-01

    The ability to reliably quantify activity in nuclear medicine has a number of increasingly important applications. Dosimetry for targeted therapy treatment planning or for approval of new imaging agents requires accurate estimation of the activity in organs, tumors, or voxels at several imaging time points. Another important application is the use of quantitative metrics derived from images, such as the standard uptake value commonly used in positron emission tomography (PET), to diagnose and follow treatment of tumors. These measures require quantification of organ or tumor activities in nuclear medicine images. However, there are a number of physical, patient, and technical factors that limit the quantitative reliability of nuclear medicine images. There have been a large number of improvements in instrumentation, including the development of hybrid single-photon emission computed tomography/computed tomography and PET/computed tomography systems, and reconstruction methods, including the use of statistical iterative reconstruction methods, which have substantially improved the ability to obtain reliable quantitative information from planar, single-photon emission computed tomography, and PET images. PMID:22475429

  9. A nuclear method to authenticate Buddha images

    International Nuclear Information System (INIS)

    Khaweerat, S; Ratanatongchai, W; Channuie, J; Wonglee, S; Picha, R; Promping, J; Silva, K; Liamsuwan, T

    2015-01-01

    The value of Buddha images in Thailand varies dramatically depending on authentication and provenance. In general, people use their individual skills to make the justification which frequently leads to obscurity, deception and illegal activities. Here, we propose two non-destructive techniques of neutron radiography (NR) and neutron activation autoradiography (NAAR) to reveal respectively structural and elemental profiles of small Buddha images. For NR, a thermal neutron flux of 10 5 n cm -2 s -1 was applied. NAAR needed a higher neutron flux of 10 12 n cm -2 s -1 to activate the samples. Results from NR and NAAR revealed unique characteristic of the samples. Similarity of the profile played a key role in the classification of the samples. The results provided visual evidence to enhance the reliability of authenticity approval. The method can be further developed for routine practice which impact thousands of customers in Thailand. (paper)

  10. A nuclear method to authenticate Buddha images

    Science.gov (United States)

    Khaweerat, S.; Ratanatongchai, W.; Channuie, J.; Wonglee, S.; Picha, R.; Promping, J.; Silva, K.; Liamsuwan, T.

    2015-05-01

    The value of Buddha images in Thailand varies dramatically depending on authentication and provenance. In general, people use their individual skills to make the justification which frequently leads to obscurity, deception and illegal activities. Here, we propose two non-destructive techniques of neutron radiography (NR) and neutron activation autoradiography (NAAR) to reveal respectively structural and elemental profiles of small Buddha images. For NR, a thermal neutron flux of 105 n cm-2s-1 was applied. NAAR needed a higher neutron flux of 1012 n cm-2 s-1 to activate the samples. Results from NR and NAAR revealed unique characteristic of the samples. Similarity of the profile played a key role in the classification of the samples. The results provided visual evidence to enhance the reliability of authenticity approval. The method can be further developed for routine practice which impact thousands of customers in Thailand.

  11. In vivo nuclear imaging of apoptosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Sup; Cheon, Gi Jeong [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2004-04-01

    Apoptosis plays a role in the pathophysiology of many kinds of diseases and in the response of treatment. Compared to the necrosis, the apoptosis a genetically controlled and energy-dependent process which removes the unwanted cells from the body; programmed cell death or cell suicide. During the apoptosis, phosphatidylserine is expressed in the cytoplasmic outer membrane in the early phase. Annexin V, an endogenous human protein (MW=35 kD), has an affinity of about 10{sup -9} M for the phosphatidylserine exposed on the outer membrane of apoptotic cells. Annexin V can be radiolabeled with {sup 99}mTc by HYNIC or EC chelators, which can be used as an radiotracer for the in vivo imaging of apoptosis. In this article, we reviewed the apoptosis, radiolabeling of annexin V, and the experimental and clinical data using annexin V imaging.

  12. Image in nuclear dosimetry using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Guinsburg, G.; Matsuoka, M.; Watanabe, S.

    1987-01-01

    A low cost methodology to produce images of internal sick organs by radioisotopic intake, is presented. Dosimetries of thermoluminescent material and Teflon (ratio:50%) in bidimensional matrix shape are used with a Pb collimator. This collimator-bidimensional matrix system was tested ''in vivo'' and in thyroid phantoms using 99m Tc. A comparative evaluation between this method and the scintigraphy one is presented. (M.A.C.) [pt

  13. Nuclear transverse sectional brain function imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1982-01-01

    A transverse radionuclide scan field imaging apparatus comprises a plurality of highly focused closely laterally adjacent collimators arranged inwardly focused in an array that surrounds a scan field of interest. Each collimator is moveable relative to its adjacent collimator. Means are provided for imparting travel to the collimators such that the focal point of each uniformly samples at least one half of the scan field

  14. A Nuclear Medthod to Authenticate Buddha Images

    International Nuclear Information System (INIS)

    Khaweerat, S.; Ratanatongchai, W.; Channuie, J.; Wonglee, S.; Picha, R.; Promping, J.; Silva, K.; Liamsuwan, T.

    2014-01-01

    The value of Buddha images in Thailand change dramatically depending on authentication and provenance. In general, people use their individual skills to make justification which frequently lead to obscurity, deception and unlawful activities. Here, we proposed a non-destructive technique of neutron-activation-autoradiography to reveal structural and elemental profiles of small Buddha images. With neutron flux of 1012 cm-2s-1, irradiation conditions were varied from 10 seconds to 1 hour for obtaining wide range of elemental composition in objects. Autoradiograph of particular objects demonstrates unique profiles at a time. In complimentary with INAA qualitative data, the profile integration was carried out. Similarity of profile plays a key role in object classification. The genuine profile was established and used as prototype model to compare with other suspects. The results provide significant evidences to ensure the accurate justification. On the other hand, the method can be further developed for routine practice which impact thousands of customers. TINT is possible to be only one authorized organization in Thailand to provide authentication certification of Buddha images in the near future.

  15. Evaluation and Immunohistochemical Qualification of Carbogen-Induced ΔR{sub 2}* as a Noninvasive Imaging Biomarker of Improved Tumor Oxygenation

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Lauren C.J., E-mail: lauren.baker@icr.ac.uk [Cancer Research UK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom); Boult, Jessica K.R.; Jamin, Yann; Gilmour, Lesley D.; Walker-Samuel, Simon; Burrell, Jake S. [Cancer Research UK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom); Ashcroft, Margaret [Division of Medicine, Centre for Cell Signalling and Molecular Genetics, University College London, London (United Kingdom); Howe, Franklyn A. [St. George' s, University of London, London (United Kingdom); Griffiths, John R. [Cancer Research UK Cambridge Institute, Cambridge (United Kingdom); Raleigh, James A. [Department of Radiation Oncology, University of North Carolina, Chapel Hill, North Carolina (United States); Kogel, Albert J. van der [University of Nijmegen Medical Centre, Nijmegen (Netherlands); Robinson, Simon P. [Cancer Research UK and EPSRC Cancer Imaging Centre, Division of Radiotherapy and Imaging, The Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom)

    2013-09-01

    Purpose: To evaluate and histologically qualify carbogen-induced ΔR{sub 2}* as a noninvasive magnetic resonance imaging biomarker of improved tumor oxygenation using a double 2-nitroimidazole hypoxia marker approach. Methods and Materials: Multigradient echo images were acquired from mice bearing GH3 prolactinomas, preadministered with the hypoxia marker CCI-103F, to quantify tumor R{sub 2}* during air breathing. With the mouse remaining positioned within the magnet bore, the gas supply was switched to carbogen (95% O{sub 2}, 5% CO{sub 2}), during which a second hypoxia marker, pimonidazole, was administered via an intraperitoneal line, and an additional set of identical multigradient echo images acquired to quantify any changes in tumor R{sub 2}*. Hypoxic fraction was quantified histologically using immunofluorescence detection of CCI-103F and pimonidazole adduct formation from the same whole tumor section. Carbogen-induced changes in tumor pO{sub 2} were further validated using the Oxylite fiberoptic probe. Results: Carbogen challenge significantly reduced mean tumor R{sub 2}* from 116 ± 13 s{sup −1} to 97 ± 9 s{sup −1} (P<.05). This was associated with a significantly lower pimonidazole adduct area (2.3 ± 1%), compared with CCI-103F (6.3 ± 2%) (P<.05). A significant correlation was observed between ΔR{sub 2}* and Δhypoxic fraction (r=0.55, P<.01). Mean tumor pO{sub 2} during carbogen breathing significantly increased from 6.3 ± 2.2 mm Hg to 36.0 ± 7.5 mm Hg (P<.01). Conclusions: The combined use of intrinsic susceptibility magnetic resonance imaging with a double hypoxia marker approach corroborates carbogen-induced ΔR{sub 2}* as a noninvasive imaging biomarker of increased tumor oxygenation.

  16. Hardware and software for image acquisition in nuclear medicine

    International Nuclear Information System (INIS)

    Fideles, E.L.; Vilar, G.; Silva, H.S.

    1992-01-01

    A system for image acquisition and processing in nuclear medicine is presented, including the hardware and software referring to acquisition. The hardware is consisted of an analog-digital conversion card, developed in wire-wape. Its function is digitate the analogic signs provided by gamma camera. The acquisitions are made in list or frame mode. (C.G.C.)

  17. Pseudo-color processing in nuclear medical image

    International Nuclear Information System (INIS)

    Wang Zhiqian; Jin Yongjie

    1992-01-01

    The application of pseudo-color technology in nuclear medical image processing is discussed. It includes selection of the number of pseudo-colors, method of realizing pseudo-color transformation, function of pseudo-color transformation and operation on the function

  18. Nuclear Medicine Imaging in the Dentomaxillofacial Region.

    Science.gov (United States)

    Wassef, Heidi R; Colletti, Patrick M

    2018-07-01

    Nuclear medicine studies evaluate physiology on a molecular level providing earlier detection of lesions before morphologic change is evident. 99m Tc-MDP and 18 F-fluoride bone scans detect osteomyelitis earlier than radiographs and computed tomography (CT); aid in diagnosis of temporomandibular joint disorder; and evaluate activity of condylar hyperplasia, extent of Paget disease, and viability of bone grafts. 18 F-FDG PET/CT distinguish between soft tissue and bone infections and diagnose osteomyelitis complicated by fracture or surgery. FDG PET is more accurate than CT alone and has a major role in staging, restaging, and assessing response to therapy for head and neck malignancies and in detecting sequelae of therapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. The influence nuclear power has on corporate image and the effect of offering merit information of nuclear power

    International Nuclear Information System (INIS)

    Oiso, Shinichi

    2006-01-01

    Many electric power companies in Japan, irrespective of their nuclear power generation ratio's difference, have nuclear power plants. These days, corporate brand image is becoming more and more important. Therefore, a survey was carried out to study the effect that nuclear power (including comparison with the other type of industry besides electric power) has on the corporate image of an electric power company. Further more, the survey includes a research about the effect on people's attitude change towards nuclear power before and after discovering the merits or benefits of nuclear power. The possibility of enhancing the corporate brand image of electric power companies by providing merit information of nuclear power was studied. (author)

  20. Progress on molecular imaging

    International Nuclear Information System (INIS)

    Chen Quan; Zhang Yongxue

    2011-01-01

    Molecular imaging is a new era of medical imaging,which can non-invasively monitor biological processes at the cellular and molecular level in vivo, including molecular imaging of nuclear medicine, magnetic resonance molecular imaging, ultrasound molecular imaging,optical molecular imaging and molecular imaging with X-ray. Recently, with the development of multi-subjects amalgamation, multimodal molecular imaging technology has been applied in clinical imaging, such as PET-CT and PET-MRI. We believe that with development of molecular probe and multi-modal imaging, more and more molecular imaging techniques will be applied in clinical diagnosis and treatment. (authors)

  1. Nuclear magnetic resonance imaging of the head

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Lukas, P.; Sehlen, S.; Weidenmaier, W.; Steiner, G.

    1990-01-01

    This pocket book is a clearly arranged and amply illustrated textbook presenting practice-oriented information for readers who seek a concise but nevertheless complete introduction to the complex subject: The technical aspects and physical principles are explained, and a catalogue of reference data and principles for image interpretation is given. The specific information refers to the clinical neuroanatomy and neuropathology of the most frequent lesions (intracranial tumors; cerebrovascular, inflammatory and degenerative lesions; hydrocephalus, multiple sclerosis, traumata, post-surgical changes, radiation effects). There also is a chapter discussing neuropediatric lesions. (orig.) With 257 ill. covering 401 figs., 15 tabs [de

  2. The public image and image shaping of the nuclear and radiation safety regulatory organization

    International Nuclear Information System (INIS)

    Li Zhiguo

    2013-01-01

    Good image is the basis of trust. It is imminent to build good public image as our society and the public pay close attention to the negative information of relevant government departments which directly or indirectly affects the public image of the government departments in recent years. In order to promote the public image of the government regulatory department, it is required for all staff to figure out how to conscientiously fulfill social responsibility, how to respond to and properly handle emergencies, and how to establish and improve a full-time public relations team. Based on nuclear and radiation safety regulatory task, this paper discussed the necessity of government departments to set up the public image, and how to shape the public image of the nuclear and radiation safety regulatory organization. (author)

  3. Non-invasive characterization of normal and pathological tissues through dynamic infrared imaging in the hamster cheek pouch oral cancer model

    Science.gov (United States)

    Herrera, María. S.; Monti Hughes, Andrea; Salva, Natalia; Padra, Claudio; Schwint, Amanda; Santa Cruz, Gustavo A.

    2017-05-01

    Biomedical infrared thermography, a non-invasive and functional imaging method, provides information on the normal and abnormal status and response of tissues in terms of spatial and temporal variations in body infrared radiance. It is especially attractive in cancer research due to the hypervascular and hypermetabolic activity of solid tumors. Moreover, healthy tissues like skin or mucosa exposed to radiation can be examined since inflammation, changes in water content, exudation, desquamation, erosion and necrosis, between others, are factors that modify their thermal properties. In this work we performed Dynamic Infrared Imaging (DIRI) to contribute to the understanding and evaluation of normal tissue, tumor and precancerous tissue response and radiotoxicity in an in vivo model, the hamster cheek pouch, exposed to Boron Neutron Capture Therapy. In this study, we particularly focused on the observation of temperature changes under forced transient conditions associated with mass moisture transfer in the tissue-air interface, in each tissue with or without treatment. We proposed a simple mathematical procedure that considerers the heat transfer from tissue to ambient through convection and evaporation to model the transient (exponential decay o recover) thermal study. The data was fitted to determined the characteristic decay and recovery time constants of the temperature as a function of time. Also this model allowed to explore the mass flux of moisture, as a degree of evaporation occurring on the tissue surface. Tissue thermal responses under provocation tests could be used as a non-invasive method to characterize tissue physiology.

  4. Are novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Habets, Jesse; Mali, Willem P.T.M. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Reitsma, Johannes B. [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Brink, Renee B.A. van den [Academic Medical Center, Department of Cardiology, Amsterdam (Netherlands); Chamuleau, Steven A.J. [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-07-15

    Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100 %; 82/95 %, and 88/94 %, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93 %, 86/98 %, and 100/94 %, respectively. TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. (orig.)

  5. Are novel non-invasive imaging techniques needed in patients with suspected prosthetic heart valve endocarditis? A systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Tanis, Wilco; Reitsma, Johannes B.; Brink, Renee B.A. van den; Chamuleau, Steven A.J.; Budde, Ricardo P.J.

    2015-01-01

    Multimodal non-invasive imaging plays a key role in establishing a diagnosis of PHV endocarditis. The objective of this study was to provide a systematic review of the literature and meta-analysis of the diagnostic accuracy of TTE, TEE, and MDCT in patients with (suspected) PHV endocarditis. Studies published between 1985 and 2013 were identified via search and cross-reference of PubMed/Embase databases. Studies were included if (1) they reported on the non-invasive index tests TTE, TEE, or MDCT; (2) data was provided on PHV endocarditis as the condition of interest; and (3) imaging results were verified against either surgical inspection/autopsy or clinical follow-up reference standards, thereby enabling the extraction of 2-by-2 tables. Twenty articles (including 496 patients) met the inclusion criteria for PHV endocarditis. TTE, TEE, and MDCT + TEE had a pooled sensitivity/specificity for vegetations of 29/100 %; 82/95 %, and 88/94 %, respectively. The pooled sensitivity/specificity of TTE, TEE, and MDCT + TEE for periannular complications was 36/93 %, 86/98 %, and 100/94 %, respectively. TEE showed good sensitivity and specificity for establishing a diagnosis of PHV endocarditis. Although MDCT data are limited, this review showed that MDCT in addition to TEE may improve sensitivity in detecting life-threatening periannular complications. (orig.)

  6. A dual function fusion protein of Herpes simplex virus type 1 thymidine kinase and firefly luciferase for noninvasive in vivo imaging of gene therapy in malignant glioma.

    Science.gov (United States)

    Söling, Ariane; Theiss, Christian; Jungmichel, Stephanie; Rainov, Nikolai G

    2004-08-04

    BACKGROUND: Suicide gene therapy employing the prodrug activating system Herpes simplex virus type 1 thymidine kinase (HSV-TK)/ ganciclovir (GCV) has proven to be effective in killing experimental brain tumors. In contrast, glioma patients treated with HSV-TK/ GCV did not show significant treatment benefit, most likely due to insufficient transgene delivery to tumor cells. Therefore, this study aimed at developing a strategy for real-time noninvasive in vivo monitoring of the activity of a therapeutic gene in brain tumor cells. METHODS: The HSV-TK gene was fused to the firefly luciferase (Luc) gene and the fusion construct HSV-TK-Luc was expressed in U87MG human malignant glioma cells. Nude mice with subcutaneous gliomas stably expressing HSV-TK-Luc were subjected to GCV treatment and tumor response to therapy was monitored in vivo by serial bioluminescence imaging. Bioluminescent signals over time were compared with tumor volumes determined by caliper. RESULTS: Transient and stable expression of the HSV-TK-Luc fusion protein in U87MG glioma cells demonstrated close correlation of both enzyme activities. Serial optical imaging of tumor bearing mice detected in all cases GCV induced death of tumor cells expressing the fusion protein and proved that bioluminescence can be reliably used for repetitive and noninvasive quantification of HSV-TK/ GCV mediated cell kill in vivo. CONCLUSION: This approach may represent a valuable tool for the in vivo evaluation of gene therapy strategies for treatment of malignant disease.

  7. New imaging systems in nuclear medicine

    International Nuclear Information System (INIS)

    1989-01-01

    PCR-I, an analog coded single ring positron tomograph, demonstrates the concepts of analog coding and the utility of high resolution systems. PCR-I, with a resolution of 4.5mm, has been employed in a series of biological studies using small animals that have been highly successful and will lead to clinical application. The emphasis now is turning to even higher sensitivity instruments in order to provide adequate number of events to populate a volume image. For this purpose, we have designed and are constructing PCR-II, a cylindrical analog coded positron tomograph incorporating 12,800 small detectors coded to 1760 phototubes. The increased sensitivity is achieved by recording all events within a cylindrical source that produce annihilation radiation striking any point on the cylindrical detector. PCR-II is projected to have a sensitivity of 1.6 million counts per second for a 20 centimeter diameter sphere uniformly filled with activity at 1 μCi/cm 3 . This system, with a resolution of 3mm, will approach the limits of sensitivity and resolution for positron tomographs. It is our opinion that this system will revolutionize the concept of positron imaging

  8. Some computer applications and digital image processing in nuclear medicine

    International Nuclear Information System (INIS)

    Lowinger, T.

    1981-01-01

    Methods of digital image processing are applied to problems in nuclear medicine imaging. The symmetry properties of central nervous system lesions are exploited in an attempt to determine the three-dimensional radioisotope density distribution within the lesions. An algorithm developed by astronomers at the end of the 19th century to determine the distribution of matter in globular clusters is applied to tumors. This algorithm permits the emission-computed-tomographic reconstruction of spherical lesions from a single view. The three-dimensional radioisotope distribution derived by the application of the algorithm can be used to characterize the lesions. The applicability to nuclear medicine images of ten edge detection methods in general usage in digital image processing were evaluated. A general model of image formation by scintillation cameras is developed. The model assumes that objects to be imaged are composed of a finite set of points. The validity of the model has been verified by its ability to duplicate experimental results. Practical applications of this work involve quantitative assessment of the distribution of radipharmaceuticals under clinical situations and the study of image processing algorithms

  9. Nuclear medicine and multimodality imaging of pediatric neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Wolfgang Peter; Pfluger, Thomas [Ludwig-Maximilians-University of Munich, Department of Nuclear Medicine, Munich (Germany); Coppenrath, Eva [Ludwig-Maximilians-University of Munich, Department of Radiology, Munich (Germany)

    2013-04-15

    Neuroblastoma is an embryonic tumor of the peripheral sympathetic nervous system and is metastatic or high risk for relapse in nearly 50% of cases. Therefore, exact staging with radiological and nuclear medicine imaging methods is crucial for defining the adequate therapeutic choice. Tumor cells express the norepinephrine transporter, which makes metaiodobenzylguanidine (MIBG), an analogue of norepinephrine, an ideal tumor specific agent for imaging. MIBG imaging has several disadvantages, such as limited spatial resolution, limited sensitivity in small lesions and the need for two or even more acquisition sessions. Most of these limitations can be overcome with positron emission tomography (PET) using [F-18]2-fluoro-2-deoxyglucose [FDG]. Furthermore, new tracers, such as fluorodopa or somatostatin receptor agonists, have been tested for imaging neuroblastoma recently. However, MIBG scintigraphy and PET alone are not sufficient for operative or biopsy planning. In this regard, a combination with morphological imaging is indispensable. This article will discuss strategies for primary and follow-up diagnosis in neuroblastoma using different nuclear medicine and radiological imaging methods as well as multimodality imaging. (orig.)

  10. Non-invasive in vivo imaging of arthritis in a collagen-induced murine model with phosphatidylserine-binding near-infrared (NIR) dye.

    Science.gov (United States)

    Chan, Marion M; Gray, Brian D; Pak, Koon Y; Fong, Dunne

    2015-03-09

    Development of non-invasive molecular imaging techniques that are based on cellular changes in inflammation has been of active interest for arthritis diagnosis. This technology will allow real-time detection of tissue damage and facilitate earlier treatment of the disease, thus representing an improvement over X-rays, which detect bone damage at the advanced stage. Tracing apoptosis, an event occurring in inflammation, has been a strategy used. PSVue 794 is a low-molecular-weight, near-infrared (NIR)-emitting complex of bis(zinc2+-dipicolylamine) (Zn-DPA) that binds to phosphatidylserine (PS), a plasma membrane anionic phospholipid that becomes flipped externally upon cell death by apoptosis. In this study, we evaluated the capacity of PSVue 794 to act as an in vivo probe for non-invasive molecular imaging assessment of rheumatoid arthritis (RA) via metabolic function in murine collagen-induced arthritis, a widely adopted animal model for RA. Male DBA/1 strain mice were treated twice with chicken collagen type II in Freund's adjuvant. Their arthritis development was determined by measuring footpad thickness and confirmed with X-ray analysis and histology. In vivo imaging was performed with the NIR dye and the LI-COR Odyssey Image System. The level of emission was compared among mice with different disease severity, non-arthritic mice and arthritic mice injected with a control dye without the Zn-DPA targeting moiety. Fluorescent emission correlated reliably with the degree of footpad swelling and the manifestation of arthritis. Ex vivo examination showed emission was from the joint. Specificity of binding was confirmed by the lack of emission when arthritic mice were given the control dye. Furthermore, the PS-binding protein annexin V displaced the NIR dye from binding, and the difference in emission was numerically measurable on a scale. This report introduces an economical alternative method for assessing arthritis non-invasively in murine models. Inflammation in

  11. The origins and future of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wehrli, F.W.

    1992-01-01

    What began as a curiosity of physics has become the preeminent method of diagnostic medical imaging and may displace x-ray-based techniques in the 21st century. During the past two decades nuclear magnetic resonance has revolutionized chemistry, biochemistry, biology and, more recently, diagnostic medicine. Nuclear magnetic resonance imaging, (MRI) as it is commonly called, is fundamentally different from x-ray-based techniques in terms of the principles of spatial encoding and mechanisms of signal and contrast generation involved. MRI has a far richer ultimate potential than any other imaging technique known today, and its technology and applications are still far from maturation, which may not occur until early in the 21st century. 23 refs., 6 figs

  12. Identification of Two Distinct Molecular Subtypes of Non-Invasive Follicular Neoplasm with Papillary-Like Nuclear Features by Digital RNA Counting.

    Science.gov (United States)

    Giannini, Riccardo; Ugolini, Clara; Poma, Anello Marcello; Urpì, Maria; Niccoli, Cristina; Elisei, Rossella; Chiarugi, Massimo; Vitti, Paolo; Miccoli, Paolo; Basolo, Fulvio

    2017-10-01

    The follicular variant (FV) of papillary thyroid cancer (PTC) is one of the most common variants of PTC. Clinically, non-infiltrative FVPTC is considered a low-risk variant of PTC, and the non-invasive encapsulated forms of FVPTC represent a group of thyroid tumors with a particularly good prognosis. Consequently, these neoplasms have been very recently reclassified as non-invasive follicular neoplasms with papillary-like nuclear features (NIFTP). From a molecular standpoint, NIFTP appears to be similar to follicular neoplasms. However, only limited data are currently available regarding their gene expression profile. The aim of this study was to identify specific molecular signatures of 26 NIFTPs compared to those of 19 follicular adenomas (FAs) and 18 infiltrative FVPTCs (IFVPTCs). A nanoString custom assay was used to perform mRNA expression analysis. All cases were also genotyped for BRAF, N-, H-, and K-RAS mutations. Samples were grouped on the basis of gene expression profiles by Pearson's correlation and non-negative matrix factorization clustering analysis. Finally, the uncorrelated shrunken centroid machine-learning algorithm was used to classify the samples. The results revealed distinct expression profiles of FAs and IFVPTCs. NIFTP samples can exhibit different expression profiles, more similar to FAs (FA-like) or to IFVPTCs (IFVPTC-like), and these different expression profiles largely depend on the presence of different mutations (RAS or BRAF). In conclusion, although further validation of the model is required by using a larger group of prospective cases, these data reinforce the hypothesis that IFVPTC-like NIFTPs might represent precursors of IFVPTC.

  13. Nuclear medicine and imaging research. Progress report, January 1, 1981-December 31, 1981

    International Nuclear Information System (INIS)

    Beck, R.N.; Cooper, M.C.

    1981-09-01

    The Progress Report for the period January 1, 1981-December 31, 1981 of the Franklin Memorial Research Institute discusses instrumentation and quantitative methods of evaluation in nuclear medicine and imaging research. Imaging systems and image evaluation are discussed in four projects: Radiation Detector Studies, Dual Purpose Scanner for Thyroid Imaging, Instrumentation for Image Processing and Enhancement, and Energy-Coded Processing in Nuclear Medicine

  14. The design of a new model circuit for image acquisition from nuclear medicine

    International Nuclear Information System (INIS)

    Zhang Nan; Jin Yongjie

    1995-01-01

    A new practical model of image acquisition circuit is given. It can be applied to data acquisition system of γ camera from nuclear medicine directly. Its idea also can be applied to some image acquisition system of nuclear event

  15. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension

    International Nuclear Information System (INIS)

    Eisenberg, B.M.; Linss, G.

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.) [de

  16. Diffractive Imaging of Coherent Nuclear Motion in Isolated Molecules

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jie; Guehr, Markus; Shen, Xiaozhe; Li, Renkai; Vecchione, Theodore; Coffee, Ryan; Corbett, Jeff; Fry, Alan; Hartmann, Nick; Hast, Carsten; Hegazy, Kareem; Jobe, Keith; Makasyuk, Igor; Robinson, Joseph; Robinson, Matthew S.; Vetter, Sharon; Weathersby, Stephen; Yoneda, Charles; Wang, Xijie; Centurion, Martin

    2016-10-03

    Observing the motion of the nuclear wave packets during a molecular reaction, in both space and time, is crucial for understanding and controlling the outcome of photoinduced chemical reactions. We have imaged the motion of a vibrational wave packet in isolated iodine molecules using ultrafast electron diffraction with relativistic electrons. The time-varying interatomic distance was measured with a precision 0.07 Å and temporal resolution of 230 fs full width at half maximum. The method is not only sensitive to the position but also the shape of the nuclear wave packet.

  17. Production of sestamibi kit for nuclear imaging

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Hakim; Zakaria, Ahmad; Yaacob, Hadzri; Ramli, Jamaluddin [Universiti Sains Malaysia, Kelantan (Malaysia). School of Medical Sciences

    1997-12-01

    One of the research projects undertaken during the implementation of the IAEA Technical Assistance Cooperation Program in our department was inhouse production of sestamibi (MIBI) kit to be labelled with Tc99m pertechnetate for myocardial studies and for malignant tumor imaging. 100 mg raw materials of sestamibi was supplied by IAEA and the kit was prepared based on Janoki recipe. Using 6 mg MIBI, 192 mg glycine, 3.6 mg stannous chloride, 62.4 mg Na sub 4 Po sub 4 and 24 mg cysteine we have prepared 24 vials of MIBI kit under sterile condition and stored in the freezer at -70 degree C. The sterility of the kit was confirmed by microbiological test using cultured method. The stability test was done by labelling the kit with Tc-99m pertechnetate at day 1, 3, 7, 30 and 60 days after kit preparation. Using two system butanone and saline with ITLC the labelling efficiency of Tc-99m (MIBI) was found to be more than 90% in each case. The labelling efficiency was found to maintain at 90% up to 24 hours post reconstitution at room temperature. Biodistribution study was carried out by administering Tc-99m (MIBI) to mice intravenously at the dosage of IOO {mu} Ci per 20 gm body weight. The mice were sacrificed at 3 hours and 24 hours after the dose administration. Blood, heart, lung, intestine, kidney and stomach samples were obtained, weighed and measured for radioactivity using gamma well counter. The data showed that after 3 hours about 60% of the injected dose accumulated in the intestine which was in agreement with IAEA standard. At 24 hours the amount in the heart still remained about 25% of the 3 hour uptake. In house production of MIBI kit is easy, fast and cost effective. The data suggested that the quality of our kit was good enough to be used for further animal research and clinical trials.

  18. [Situation of supply and boom of PET imaging: what is the future for technetium-99m in nuclear medicine?].

    Science.gov (United States)

    Maia, S; Ayachi Hatit, N; Paycha, F

    2011-05-01

    Molecular imaging has shown its interest in the diagnosis, staging and therapy monitoring of many diseases, especially in the field of cancer. This imaging modality can detect non-invasively early molecular changes specific to these diseases. Its expansion includes two aspects linked firstly with the advanced techniques of imaging modalities and secondly with the development of tracers as radio pharmaceuticals for imaging new molecular targets. Technetium-99m ((99m)Tc), because of its physical characteristics, its widespread availability and low cost, is the most used radionuclide in molecular imaging with the technique of single photon emission computed tomography (SPECT). Nevertheless, the current difficulty concerning the supply and the great interest of Positron Emission Tomography (PET), the "competitor" imaging modality-using molecules labelled with fluorine-18 ((18)F), legitimates the question about the future of (99m)Tc, its supremacy and the emergence of new tracer labelled with (99m)Tc. Focusing on the actual and future supply situation, the place of SPECT imaging in nuclear medicine, as well as the development of new molecules labelled with (99m)Tc is necessary to show that this radionuclide will remain essential for the speciality in the next years. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  19. Cardiac memory in patients with Wolff-Parkinson-White syndrome: noninvasive imaging of activation and repolarization before and after catheter ablation.

    Science.gov (United States)

    Ghosh, Subham; Rhee, Edward K; Avari, Jennifer N; Woodard, Pamela K; Rudy, Yoram

    2008-08-26

    Cardiac memory refers to a change in ventricular repolarization induced by and persisting for minutes to months after cessation of a period of altered ventricular activation (eg, resulting from pacing or preexcitation in patients with Wolff-Parkinson-White syndrome). ECG imaging (ECGI) is a novel imaging modality for noninvasive electroanatomic mapping of epicardial activation and repolarization. Fourteen pediatric patients with Wolff-Parkinson-White syndrome and no other congenital disease, were imaged with ECGI a day before and 45 minutes, 1 week, and 1 month after successful catheter ablation. ECGI determined that preexcitation sites were consistent with sites of successful ablation in all cases to within a 1-hour arc of each atrioventricular annulus. In the preexcited rhythm, activation-recovery interval (ARI) was the longest (349+/-6 ms) in the area of preexcitation leading to high average base-to-apex ARI dispersion of 95+/-9 ms (normal is approximately 40 ms). The ARI dispersion remained the same 45 minutes after ablation, although the activation sequence was restored to normal. ARI dispersion was still high (79+/-9 ms) 1 week later and returned to normal (45+/-6 ms) 1 month after ablation. The study demonstrates that ECGI can noninvasively localize ventricular insertion sites of accessory pathways to guide ablation and evaluate its outcome in pediatric patients with Wolff-Parkinson-White syndrome. Wolff-Parkinson-White is associated with high ARI dispersion in the preexcited rhythm that persists after ablation and gradually returns to normal over a period of 1 month, demonstrating the presence of cardiac memory. The 1-month time course is consistent with transcriptional reprogramming and remodeling of ion channels.

  20. Nuclear medicine image and data interchange through e-mail

    Energy Technology Data Exchange (ETDEWEB)

    Lyra, M; Skouroliakou, K; Perris, A; Georgossopoulos, C; Pappas, D [Radiology Department, Athens University, Athens (Greece); Stefanides, C [Pediatric Hospital, Aglaia Kyriakou, Athens (Greece)

    1999-12-31

    Prosperity of easy interchange in every day practice of Nuclear Medicine found its application through the INTERNET media. We use a simple and safe way to interchange images and diagnostic information between the scintigraphic acquisition and processing location and the clinical department in order to improve patient`s health care and young doctor`s education. images and patient reports are transferred and saved through dedicated software to a workstation that transforms y-camera scintigraphic images in a PC readable format. Diagnosis reports and scintigraphic images are incorporated to a database directory in hypertext form. Usual WWW connection gives the possibility of patients` examinations transfer by email attachments as well as interchange of relative comments towards both directions. Cost effective solution has been achieved using standard hard- and soft-ware. Furthermore, both educational files can be downloaded from our department ftp location, by a unique password. (authors) 7 refs., 3 figs.

  1. Nuclear medicine image and data interchange through e-mail

    International Nuclear Information System (INIS)

    Lyra, M.; Skouroliakou, K.; Perris, A.; Georgossopoulos, C.; Pappas, D.; Stefanides, C.

    1998-01-01

    Prosperity of easy interchange in every day practice of Nuclear Medicine found its application through the INTERNET media. We use a simple and safe way to interchange images and diagnostic information between the scintigraphic acquisition and processing location and the clinical department in order to improve patient's health care and young doctor's education. images and patient reports are transferred and saved through dedicated software to a workstation that transforms y-camera scintigraphic images in a PC readable format. Diagnosis reports and scintigraphic images are incorporated to a database directory in hypertext form. Usual WWW connection gives the possibility of patients' examinations transfer by email attachments as well as interchange of relative comments towards both directions. Cost effective solution has been achieved using standard hard- and soft-ware. Furthermore, both educational files can be downloaded from our department ftp location, by a unique password. (authors)

  2. Restoration of nuclear medicine images using adaptive Wiener filters

    International Nuclear Information System (INIS)

    Meinel, G.

    1989-01-01

    An adaptive Wiener filter implementation for restoration of nuclear medicine images is described. These are considerably disturbed both deterministically (definition) and stochastically (Poisson's quantum noise). After introduction of an image model, description of necessary parameter approximations and information on optimum design methods the implementation is described. The filter operates adaptively as concerns the local signal-to-noise ratio and is based on a filter band concept. To verify the restoration effect size numbers are introduced and the filter is tested against these numbers. (author)

  3. Magnetic imaging: a new tool for UK national nuclear security.

    Science.gov (United States)

    Darrer, Brendan J; Watson, Joe C; Bartlett, Paul; Renzoni, Ferruccio

    2015-01-22

    Combating illicit trafficking of Special Nuclear Material may require the ability to image through electromagnetic shields. This is the case when the trafficking involves cargo containers. Thus, suitable detection techniques are required to penetrate a ferromagnetic enclosure. The present study considers techniques that employ an electromagnetic based principle of detection. It is generally assumed that a ferromagnetic metallic enclosure will effectively act as a Faraday cage to electromagnetic radiation and therefore screen any form of interrogating electromagnetic radiation from penetrating, thus denying the detection of any eventual hidden material. In contrast, we demonstrate that it is actually possible to capture magnetic images of a conductive object through a set of metallic ferromagnetic enclosures. This validates electromagnetic interrogation techniques as a potential detection tool for National Nuclear Security applications.

  4. Magnetic Imaging: a New Tool for UK National Nuclear Security

    Science.gov (United States)

    Darrer, Brendan J.; Watson, Joe C.; Bartlett, Paul; Renzoni, Ferruccio

    2015-01-01

    Combating illicit trafficking of Special Nuclear Material may require the ability to image through electromagnetic shields. This is the case when the trafficking involves cargo containers. Thus, suitable detection techniques are required to penetrate a ferromagnetic enclosure. The present study considers techniques that employ an electromagnetic based principle of detection. It is generally assumed that a ferromagnetic metallic enclosure will effectively act as a Faraday cage to electromagnetic radiation and therefore screen any form of interrogating electromagnetic radiation from penetrating, thus denying the detection of any eventual hidden material. In contrast, we demonstrate that it is actually possible to capture magnetic images of a conductive object through a set of metallic ferromagnetic enclosures. This validates electromagnetic interrogation techniques as a potential detection tool for National Nuclear Security applications.

  5. The development of nuclear medicine molecular imaging: An era of multiparametric imaging

    International Nuclear Information System (INIS)

    Zhu Yuyuan; Huang Gang

    2010-01-01

    Nuclear medical molecular imaging is developing toward a multimodality and multitracer future. Abundant complementary data generated from different tracers in different modalities are successfully serving the biological research and clinical treatment. Among the others, PER-MRI has the greatest potential and will be a research of interest in the near future. This article focused on the evolution history on nuclear medicine from single modality to multimodality, single tracer to multitracer. It also gave a brief summary to the identifications, differences, pros and consofmultimodality, multitracer, multiparametric molecular imaging. Issues, problems and challenges concerned with her development and recognition are also discussed. (authors)

  6. Image interface in Java for tomographic reconstruction in nuclear medicine

    International Nuclear Information System (INIS)

    Andrade, M.A.; Silva, A.M. Marques da

    2004-01-01

    The aim of this study is to implement a software for tomographic reconstruction of SPECT data from Nuclear Medicine with a flexible interface design, cross-platform, written in Java. Validation tests were performed based on SPECT simulated data. The results showed that the implemented algorithms and filters agree with the theoretical context. We intend to extend the system by implementing additional tomographic reconstruction techniques and Java threads, in order to provide simultaneously image processing. (author)

  7. A fast analysis method for non-invasive imaging of blood flow in individual cerebral arteries using vessel-encoded arterial spin labelling angiography

    Science.gov (United States)

    Chappell, Michael A.; Okell, Thomas W.; Payne, Stephen J.; Jezzard, Peter; Woolrich, Mark W.

    2012-01-01

    Arterial spin labelling (ASL) MRI offers a non-invasive means to create blood-borne contrast in vivo for dynamic angiographic imaging. By spatial modulation of the ASL process it is possible to uniquely label individual arteries over a series of measurements, allowing each to be separately identified in the resulting angiographic images. This separation requires appropriate analysis for which a general Bayesian framework has previously been proposed. Here this framework is adapted for clinical dynamic angiographic imaging. This specifically addresses the issues of computational speed of the algorithm and the robustness required to deal with real patient data. An algorithm is proposed that can incorporate planning information about the arteries being imaged whilst adapting for subsequent patient movement. A fast maximum a posteriori solution is adopted and shown to be only marginally less accurate than Monte Carlo sampling under simulation. The final algorithm is demonstrated on in vivo data with analysis on a time scale of the order of 10 min, from both a healthy control and a patient with a vertebro-basilar occlusion. PMID:22322066

  8. Superparamagnetic iron oxide nanoparticles function as a long-term, multi-modal imaging label for non-invasive tracking of implanted progenitor cells.

    Directory of Open Access Journals (Sweden)

    Christina A Pacak

    Full Text Available The purpose of this study was to determine the ability of superparamagnetic iron oxide (SPIO nanoparticles to function as a long-term tracking label for multi-modal imaging of implanted engineered tissues containing muscle-derived progenitor cells using magnetic resonance imaging (MRI and X-ray micro-computed tomography (μCT. SPIO-labeled primary myoblasts were embedded in fibrin sealant and imaged to obtain intensity data by MRI or radio-opacity information by μCT. Each imaging modality displayed a detection gradient that matched increasing SPIO concentrations. Labeled cells were then incorporated in fibrin sealant, injected into the atrioventricular groove of rat hearts, and imaged in vivo and ex vivo for up to 1 year. Transplanted cells were identified in intact animals and isolated hearts using both imaging modalities. MRI was better able to detect minuscule amounts of SPIO nanoparticles, while μCT more precisely identified the location of heavily-labeled cells. Histological analyses confirmed that iron oxide particles were confined to viable, skeletal muscle-derived cells in the implant at the expected location based on MRI and μCT. These analyses showed no evidence of phagocytosis of labeled cells by macrophages or release of nanoparticles from transplanted cells. In conclusion, we established that SPIO nanoparticles function as a sensitive and specific long-term label for MRI and μCT, respectively. Our findings will enable investigators interested in regenerative therapies to non-invasively and serially acquire complementary, high-resolution images of transplanted cells for one year using a single label.

  9. Parallel 3-D image processing for nuclear emulsion

    International Nuclear Information System (INIS)

    Nakano, Toshiyuki

    2001-01-01

    The history of nuclear plate was explained. The first nuclear plate was named as pellicles covered with 600 μm of emulsion in Europe. In Japan Emulsion Cloud Chamber (ECC) using thin emulsion (50 μm) type nuclear plate was developed in 1960. Then, the semi-automatic analyzer (1971) and automatic analyzer (1980), Track Selector (TS) with memory stored 16 layer images in 512 x 512 x 16 pixel were developed. Moreover, NTS (New Track Selector), speeding up analyzer, was produced for analysis of results of CHORUS experiment in 1996. Simultaneous readout of 16 layer images had been carried out, but UTS (Ultra Track Selector) made possible to progressive treatment of 16 layers of some data and determination of traces in all angles. Direct detection of tau neutrino (VT) was studied by DONUT (FNAL E872) using UTS and nuclear plate. Neutrino beam was produced by 800 GeV proton beam hitting the fixed target. About 1100 phenomena of neutrino reactions were observed during six months of irradiation. 203 phenomena were detected. 4 examples were shown in this paper. OPERA experiment by SK is explained. (S.Y.)

  10. Digital image processing for radiography in nuclear power plants

    International Nuclear Information System (INIS)

    Heidt, H.; Rose, P.; Raabe, P.; Daum, W.

    1985-01-01

    With the help of digital processing of radiographic images from reactor-components it is possible to increase the security and objectiveness of the evaluation. Several examples of image processing procedures (contrast enhancement, density profiles, shading correction, digital filtering, superposition of images etc.) show the advantages for the visualization and evaluation of radiographs. Digital image processing can reduce some of the restrictions of radiography in nuclear power plants. In addition a higher degree of automation can be cost-saving and increase the quality of radiographic evaluation. The aim of the work performed was to to improve the readability of radiographs for the human observer. The main problem is lack of contrast and the presence of disturbing structures like weld seams. Digital image processing of film radiographs starts with the digitization of the image. Conventional systems use TV-cameras or scanners and provide a dynamic range of 1.5. to 3 density units, which are digitized to 256 grey levels. For the enhancement process it is necessary that the grey level range covers the density range of the important regions of the presented film. On the other hand the grey level coverage should not be wider than necessary to minimize the width of digitization steps. Poor digitization makes flaws and cracks invisible and spoils all further image processing

  11. Quantitative Nuclear Medicine Imaging: Concepts, Requirements and Methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-01-15

    The absolute quantification of radionuclide distribution has been a goal since the early days of nuclear medicine. Nevertheless, the apparent complexity and sometimes limited accuracy of these methods have prevented them from being widely used in important applications such as targeted radionuclide therapy or kinetic analysis. The intricacy of the effects degrading nuclear medicine images and the lack of availability of adequate methods to compensate for these effects have frequently been seen as insurmountable obstacles in the use of quantitative nuclear medicine in clinical institutions. In the last few decades, several research groups have consistently devoted their efforts to the filling of these gaps. As a result, many efficient methods are now available that make quantification a clinical reality, provided appropriate compensation tools are used. Despite these efforts, many clinical institutions still lack the knowledge and tools to adequately measure and estimate the accumulated activities in the human body, thereby using potentially outdated protocols and procedures. The purpose of the present publication is to review the current state of the art of image quantification and to provide medical physicists and other related professionals facing quantification tasks with a solid background of tools and methods. It describes and analyses the physical effects that degrade image quality and affect the accuracy of quantification, and describes methods to compensate for them in planar, single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. The fast paced development of the computational infrastructure, both hardware and software, has made drastic changes in the ways image quantification is now performed. The measuring equipment has evolved from the simple blind probes to planar and three dimensional imaging, supported by SPECT, PET and hybrid equipment. Methods of iterative reconstruction have been developed to allow for

  12. Gamma-ray imaging. Applications in nuclear non-proliferation and homeland security

    International Nuclear Information System (INIS)

    Vetter, Kai; Mihailescu, Lucian

    2010-01-01

    This paper provides the motivation and describes implementations of gamma-ray imaging for homeland security applications and more general for national and international nuclear security. As in nuclear medicine and astrophysics, the goal of gamma-ray imaging is the detection and localization of nuclear materials, however, here in a terrestrial environment with distances between nuclear medicine and astrophysics, i.e. in the range of 1-100 meters. Due to the recently increased threat of nuclear terrorism, the detection of illicit nuclear materials and the prevention of nuclear proliferation through the development of advanced gamma-ray imaging concepts and technologies has become and active research field. (author)

  13. Full aperture imaging with stereoscopic properties in nuclear medicine

    International Nuclear Information System (INIS)

    Strocovsky, Sergio G.; Otero, D.

    2011-01-01

    The imaging techniques based on gamma camera (CG) and used in nuclear medicine have low spatial resolution and low sensitivity due to the use of the collimator. However, this element is essential for the formation of images in CG. The aim of this work is to show the principles of a new technique to overcome the limitations of existing techniques based on CG. Here, we present a Full Aperture Imaging (FAI) technique which is based on the edge-encoding of gamma radiation and differential detection. It takes advantage of the fact that gamma radiation is spatially incoherent. The mathematical principles and the method of images reconstruction with the new proposed technique are explained in detail. The FAI technique is tested by means of Monte Carlo simulations with filiform and spherical sources. The results show that FAI technique has greater sensitivity (>100 times) and greater spatial resolution (>2.6 times) than that of GC with LEHR collimator, in both cases, with and without attenuating material and long and short-distance configurations. The FAI decoding algorithm reconstructs simultaneously four different projections which are located in separate image fields on the detector plane, while GC produces only one projection per acquisition. Simulations have allowed comparison of both techniques under ideal identical conditions. Our results show it is possible to apply an extremely simple encoded imaging technique, and get three-dimensional radioactivity information for simplistic geometry sources. The results are promising enough to evaluate the possibility of future research with more complex sources typical of nuclear medicine imaging. (author)

  14. Radiopharmacokinetics: utilization of nuclear medicine techniques in the non-invasive study of drug distribution. Progress report

    International Nuclear Information System (INIS)

    Wolf, W.

    1984-01-01

    These studies provide a basic framework in which the radiopharmokinetic models described in this report may be tested experimentally. Volume calibration factors, corrections for overlying and underlying activity, and estimates of the amount of noise in quantitative projection and tomographic images have been developed, with emphasis on particular compartments within a rat-size phantom. Studies have also been performed with live rats and the results interpreted with the aid of the physical studies described above. We expect that similar types of analyses and calibrations will be necessary in the upcoming clinical studies. 32 refs., 24 figs., 12 tabs

  15. Noise Reduction planar bone imaging nuclear medicine with the use of wavelet transform: an assessment of its quality

    International Nuclear Information System (INIS)

    Casas Cardoso, Maria del Carmen; Perez Diaz, Marlen; Casas Cardoso, Gladis; Lorenzo Ginori, Juan; Paz Viera, Juan Enrique; Roque Diaz, Reinaldo; Cardenas Barreras, Julian

    2009-01-01

    Diagnostic imaging of Nuclear Medicine (MN), is highly used in Oncology, as it constitutes a noninvasive technique that allows early detection of tumors and assessment of therapeutic response of patients under treatment. However, particularly planar scintigraphy images, can be prone to problems of detectability of small lesions, because they are contaminated with noise, a phenomenon which is accentuated by the inability to increase the dose of the radiopharmaceutical or time acquisition of images of the patient over 'certain levels'. The aim of this work is to improve the detectability of tumors of bone. We describe an algorithm for random noise reduction using the wavelet transform (TW). The quality of the resulting images are evaluated through quantitative metrics such as Signal to Noise Ratio (SNR), the Mean Square Error (NMSEA) and Structural Similarity Index (SSIM). It also includes a subjective assessment of image quality by expert criteria, using a variant of the methodology FROC (Free-Response ROC). It was found that some of the filters designed in the wavelet domain, significantly improve the quality of planar bone imaging in terms of increased signal to noise ratio without implying notable structural distortions, which facilitates clinical diagnosis. (author)

  16. Dose modeling of noninvasive image-guided breast brachytherapy in comparison to electron beam boost and three-dimensional conformal accelerated partial breast irradiation.

    Science.gov (United States)

    Sioshansi, Shirin; Rivard, Mark J; Hiatt, Jessica R; Hurley, Amanda A; Lee, Yoojin; Wazer, David E

    2011-06-01

    To perform dose modeling of a noninvasive image-guided breast brachytherapy (NIIGBB) for comparison to electrons and 3DCRT. The novel technology used in this study is a mammography-based, noninvasive breast brachytherapy system whereby the treatment applicators are centered on the planning target volume (PTV) to direct (192)Ir emissions along orthogonal axes. To date, three-dimensional dose modeling of NIIGBB has not been possible because of the limitations of conventional treatment planning systems (TPS) to model variable tissue deformation associated with breast compression. In this study, the TPS was adapted such that the NIIGBB dose distributions were modeled as a virtual point source. This dose calculation technique was applied to CT data from 8 patients imaged with the breast compressed between parallel plates in the cranial-caudal and medial-lateral axes. A dose-volume comparison was performed to simulated electron boost and 3DCRT APBI. The NIIGBB PTV was significantly reduced as compared with both electrons and 3DCRT. Electron boost plans had a lower D(min) than the NIIGBB technique but higher V(100), D(90), and D(50). With regard to PTV coverage for APBI, the only significant differences were minimally higher D(90), D(100), V(80), and V(90), with 3DCRT and D(max) with NIIGBB. The NIIGBB technique, as compared with electrons and 3D-CRT, achieved a lower maximum dose to skin (60% and 10%, respectively) and chest wall/lung (70-90%). NIIGBB achieves a PTV that is smaller than electron beam and 3DCRT techniques. This results in significant normal tissue sparing while maintaining dosimetric benchmarks to the target tissue. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Non-invasive imaging of transplanted human neural stem cells and ECM scaffold remodeling in the stroke-damaged rat brain by 19F- and diffusion-MRI

    Science.gov (United States)

    Bible, Ellen; Dell’Acqua, Flavio; Solanky, Bhavana; Balducci, Anthony; Crapo, Peter; Badylak, Stephen F.; Ahrens, Eric T.; Modo, Michel

    2012-01-01

    Transplantation of human neural stem cells (hNSCs) is emerging as a viable treatment for stroke related brain injury. However, intraparenchymal grafts do not regenerate lost tissue, but rather integrate into the host parenchyma without significantly affecting the lesion cavity. Providing a structural support for the delivered cells appears important for cell based therapeutic approaches. The non-invasive monitoring of therapeutic methods would provide valuable information regarding therapeutic strategies but remains a challenge. Labeling transplanted cells with metal-based 1H-magnetic resonance imaging (MRI) contrast agents affects the visualization of the lesion cavity. Herein, we demonstrate that a 19F-MRI contrast agent can adequately monitor the distribution of transplanted cells, whilst allowing an evaluation of the lesion cavity and the formation of new tissue on 1H-MRI scans. Twenty percent of cells labeled with the 19F-agent were of host origin, potentially reflecting the re-uptake of label from dead transplanted cells. Both T2- and diffusion-weighted MRI scans indicated that transplantation of hNSCs suspended in a gel form of a xenogeneic extracellular matrix (ECM) bioscaffold resulted in uniformly distributed cells throughout the lesion cavity. However, diffusion MRI indicated that the injected materials did not yet establish diffusion barriers (i.e. cellular network, fiber tracts) normally found within striatal tissue. The ECM bioscaffold therefore provides an important support to hNSCs for the creation of de novo tissue and multi-nuclei MRI represents an adept method for the visualization of some aspects of this process. However, significant developments of both the transplantation paradigm, as well as regenerative imaging, are required to successfully create new tissue in the lesion cavity and to monitor this process non-invasively. PMID:22244696

  18. Non-invasive imaging of transplanted human neural stem cells and ECM scaffold remodeling in the stroke-damaged rat brain by (19)F- and diffusion-MRI.

    Science.gov (United States)

    Bible, Ellen; Dell'Acqua, Flavio; Solanky, Bhavana; Balducci, Anthony; Crapo, Peter M; Badylak, Stephen F; Ahrens, Eric T; Modo, Michel

    2012-04-01

    Transplantation of human neural stem cells (hNSCs) is emerging as a viable treatment for stroke related brain injury. However, intraparenchymal grafts do not regenerate lost tissue, but rather integrate into the host parenchyma without significantly affecting the lesion cavity. Providing a structural support for the delivered cells appears important for cell based therapeutic approaches. The non-invasive monitoring of therapeutic methods would provide valuable information regarding therapeutic strategies but remains a challenge. Labeling transplanted cells with metal-based (1)H-magnetic resonance imaging (MRI) contrast agents affects the visualization of the lesion cavity. Herein, we demonstrate that a (19)F-MRI contrast agent can adequately monitor the distribution of transplanted cells, whilst allowing an evaluation of the lesion cavity and the formation of new tissue on (1)H-MRI scans. Twenty percent of cells labeled with the (19)F agent were of host origin, potentially reflecting the re-uptake of label from dead transplanted cells. Both T(2)- and diffusion-weighted MRI scans indicated that transplantation of hNSCs suspended in a gel form of a xenogeneic extracellular matrix (ECM) bioscaffold resulted in uniformly distributed cells throughout the lesion cavity. However, diffusion MRI indicated that the injected materials did not yet establish diffusion barriers (i.e. cellular network, fiber tracts) normally found within striatal tissue. The ECM bioscaffold therefore provides an important support to hNSCs for the creation of de novo tissue and multi-nuclei MRI represents an adept method for the visualization of some aspects of this process. However, significant developments of both the transplantation paradigm, as well as regenerative imaging, are required to successfully create new tissue in the lesion cavity and to monitor this process non-invasively. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Awake Craniotomy with Noninvasive Brain Mapping by 3-Tesla Functional Magnetic Resonance Imaging for Excision of Low-grade Glioma: A Case of a Young Patient from Pakistan.

    Science.gov (United States)

    Aleem Bhatti, Atta Ul; Jakhrani, Nasir Khan; Parekh, Maria Adnan

    2018-01-01

    The past few years have seen increasing support for gross total resection in the management of low-grade gliomas (LGGs), with a greater extent of resection correlated with better overall survival, progression-free survival, and time to malignant transformation. There is consistent evidence in literature supporting extent of safe resection as a good prognostic indicator as well as positively affecting seizure control, symptomatic relief in pressure symptoms, and longer progression-free and total survival. The operative goal in most LGG cases is to maximize the extent of resection for these benefits while avoiding postoperative neurologic deficits. Several advanced invasive and noninvasive surgical techniques such as intraoperative magnetic resonance imaging (MRI), fluorescence-guided surgery, intraoperative functional pathway mapping, and neuronavigation have been developed in an attempt to better achieve maximal safe resection. We present a case of LGG in a young patient with a 5-year history of refractory seizures and gradual onset walking difficulty. Serial MRI brain scans revealed a progressive increase in right frontal tumor size with substantial edema and parafalcine herniation. Noninvasive brain mapping by functional MRI (fMRI) and sleep-awake-sleep type of anesthesia with endotracheal tube insertion was utilized during an awake craniotomy. Histopathology confirmed a Grade II oligodendroglioma, and genetic analysis revealed no codeletion at 1p/19q. Neurological improvement was remarkable in terms of immediate motor improvement, and the patient remained completely seizure free on a single antiepileptic drug. There is no radiologic or clinical evidence of recurrence 6 months postoperatively. This is the first published report of an awake craniotomy for LGG in Pakistan. The contemporary concept of supratotal resection in LGGs advocates generous functional resection even beyond MRI findings rather than mere excision of oncological boundaries. This relatively

  20. PET-based molecular nuclear neuro-imaging

    International Nuclear Information System (INIS)

    Kim, Jong Ho

    2004-01-01

    Molecular nuclear neuro-imaging in CNS drug discovery and development can be divided into four categories that are clearly inter-related. (1) Neuroreceptor mapping to examine the involvement of specific neurotransmitter system in CNS diseases, drug occupancy characteristics and perhaps examine mechanisms of action;(2) Structural and spectroscopic imaging to examine morphological changes and their consequences;(3) Metabolic mapping to provide evidence of central activity and CNS fingerprinting the neuroanatomy of drug effects;(4) Functional mapping to examine disease-drug interactions. In addition, targeted delivery of therapeutic agents could be achieved by modifying stem cells to release specific drugs at the site of transplantation('stem cell pharmacology'). Future exploitation of stem cell biology, including enhanced release of therapeutic factors through genetic stem cell engineering might thus constitute promising pharmaceutical approaches to treating diseases of the nervous system. With continued improvements in instrumentation, identification of better imaging probes by innovative chemistry, molecular nuclear neuro-imaging promise to play increasingly important roles in disease diagnosis and therapy

  1. PET-based molecular nuclear neuro-imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Ho [Gil Medical Center, Gachon (Korea, Republic of)

    2004-04-01

    Molecular nuclear neuro-imaging in CNS drug discovery and development can be divided into four categories that are clearly inter-related. (1) Neuroreceptor mapping to examine the involvement of specific neurotransmitter system in CNS diseases, drug occupancy characteristics and perhaps examine mechanisms of action;(2) Structural and spectroscopic imaging to examine morphological changes and their consequences;(3) Metabolic mapping to provide evidence of central activity and CNS fingerprinting the neuroanatomy of drug effects;(4) Functional mapping to examine disease-drug interactions. In addition, targeted delivery of therapeutic agents could be achieved by modifying stem cells to release specific drugs at the site of transplantation('stem cell pharmacology'). Future exploitation of stem cell biology, including enhanced release of therapeutic factors through genetic stem cell engineering might thus constitute promising pharmaceutical approaches to treating diseases of the nervous system. With continued improvements in instrumentation, identification of better imaging probes by innovative chemistry, molecular nuclear neuro-imaging promise to play increasingly important roles in disease diagnosis and therapy.

  2. The Use of Magnetic Resonance Imaging for Non-Invasive Assessment of Venofer® Biodistribution in Rats

    NARCIS (Netherlands)

    Span, Kimberley; Pieters, Ebel H.E.; Hennink, Wim E.; van der Toorn, Annette; Brinks, Vera; Dijkhuizen, Rick M.; van Tilborg, Geralda A.F.

    2018-01-01

    Purpose: The aim of this study was to determine the potential of magnetic resonance imaging to evaluate the biodistribution of exogenous iron within 24 h after one single injection of Venofer® (iron sucrose). Methods: Venofer® was evaluated in vitro for its ability to generate contrast in MR images.

  3. NONINVASIVE OPTICAL IMAGING OF STAPHYLOCOCCUS AUREUS INFECTION IN VIVO USING AN ANTIMICROBIAL PEPTIDE FRAGMENT BASED NEAR-INFRARED FLUORESCENT PROBES

    Directory of Open Access Journals (Sweden)

    CUICUI LIU

    2013-07-01

    Full Text Available The diagnosis of bacterial infections remains a major challenge in medicine. Optical imaging of bacterial infection in living animals is usually conducted with genetic reporters such as light-emitting enzymes or fluorescent proteins. However, there are many circumstances where genetic reporters are not applicable, and there is an urgent need for exogenous synthetic probes that can selectively target bacteria. Optical imaging of bacteria in vivo is much less developed than methods such as radioimaging and MRI. Furthermore near-infrared (NIR dyes with emission wavelengths in the region of 650–900 nm can propagate through two or more centimeters of tissue and may enable deeper tissue imaging if sensitive detection techniques are employed. Here we constructed an antimicrobial peptide fragment UBI29-41-based near-infrared fluorescent imaging probe. The probe is composed of UBI29-41 conjugated to a near infrared dye ICG-Der-02. UBI29-41 is a cationic antimicrobial peptide that targets the anionic surfaces of bacterial cells. The probe allows detection of Staphylococcus aureus infection (5 × 107 cells in a mouse local infection model using whole animal near-infrared fluorescence imaging. Furthermore, we demonstrate that the UBI29-41-based imaging probe can selectively accumulate within bacteria. The significantly higher accumulation in bacterial infection suggests that UBI29-41-based imaging probe may be a promising imaging agent to detect bacterial infections.

  4. Comparison of optical and power Doppler ultrasound imaging for non-invasive evaluation of arsenic trioxide as a vascular disrupting agent in tumors.

    Science.gov (United States)

    Alhasan, Mustafa K; Liu, Li; Lewis, Matthew A; Magnusson, Jennifer; Mason, Ralph P

    2012-01-01

    Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO).During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs.The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent.

  5. Non-invasive analysis of bovine embryo metabolites during in vitro embryo culture using nuclear magnetic resonance

    Directory of Open Access Journals (Sweden)

    Marcello Rubessa

    2016-12-01

    Full Text Available The ability to identify embryos that have the highest developmental potential from a cohort would significantly increase the chances of achieving pregnancy. Metabolic analysis is a well-established analytical approach in biological systems. Starting from this idea, we chose to use high-resolution nuclear magnetic resonance (1H-NMR spectroscopy. The aim of this study was to determine if it is possible to select viable embryos after 48 h of culture using metabolic activity as the parameter. We evaluated embryo metabolism after the first 48 h of culture and compared the activity of cleaved embryos that became blastocysts to cleaved embryos that did not develop to blastocysts, and in vitro fertilized (IVF blastocysts and parthenogenetic-activated (PA blastocysts. Our results show that citrate, pyruvate, myo-inositol and lysine have great impact on predicting embryo development. When we compared IVF and PA blastocysts, we found that acetate and phenylalanine concentrations are excellent parameters for evaluating blastocyst quality. Combining all these results, we were able to create a formula that predicts zygote development after 2 days of culture. In conclusion, we found that it is possible predict the future development of in vitro produced bovine embryos after only 2 days of culture using 1H-NMR.

  6. Coded aperture imaging system for nuclear fuel motion detection

    International Nuclear Information System (INIS)

    Stalker, K.T.; Kelly, J.G.

    1980-01-01

    A Coded Aperature Imaging System (CAIS) has been developed at Sandia National Laboratories to image the motion of nuclear fuel rods undergoing tests simulating accident conditions within a liquid metal fast breeder reactor. The tests require that the motion of the test fuel be monitored while it is immersed in a liquid sodium coolant precluding the use of normal optical means of imaging. However, using the fission gamma rays emitted by the fuel itself and coded aperture techniques, images with 1.5 mm radial and 5 mm axial resolution have been attained. Using an electro-optical detection system coupled to a high speed motion picture camera a time resolution of one millisecond can be achieved. This paper will discuss the application of coded aperture imaging to the problem, including the design of the one-dimensional Fresnel zone plate apertures used and the special problems arising from the reactor environment and use of high energy gamma ray photons to form the coded image. Also to be discussed will be the reconstruction techniques employed and the effect of various noise sources on system performance. Finally, some experimental results obtained using the system will be presented

  7. Quantification of brain perfusion SPECT with N-isopropyl-p-iodoamphetamine using noninvasive microsphere method. Estimation of arterial input by dynamic imaging

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Sugihara, Hideki; Taniguchi, Yoshimitsu; Aoki, Etsuo; Furuichi, Kenji; Miyazaki, Yoshiharu.

    1997-01-01

    We have developed a noninvasive method to quantify brain perfusion SPECT with 123 I-N-isopropyl-p-iodoamphetamine (IMP) using serial dynamic planar imaging of the initial transit phase. The method is based on the microsphere model, but does not require arterial sampling. Serial dynamic planar imaging was performed for 6 min after the bolus injection of IMP (167 MBq in 1.5 ml), followed by additional planar imaging at 20 min and SPECT scan thereafter. The total arterial input to the brain during the initial 5 min after injection was estimated by the injected dose, with the correction of the lung retention, divided by cardiac output (CO). CO was estimated from the initial transit of IMP in the right heart. Cardiac output index (COI), obtained from the integral of the first transit of IMP in the right heart divided by the injected dose, was calibrated by CO measured by Doppler ultrasonography. Regional cerebral blood flow (rCBF) obtained by this method in normal subjects was acceptable. However, the results may be influenced by the injection technique, and careful attention should be considered for clinical application of this method. (author)

  8. Design and Experimental Evaluation of a Non-Invasive Microwave Head Imaging System for Intracranial Haemorrhage Detection.

    Directory of Open Access Journals (Sweden)

    A T Mobashsher

    Full Text Available An intracranial haemorrhage is a life threatening medical emergency, yet only a fraction of the patients receive treatment in time, primarily due to the transport delay in accessing diagnostic equipment in hospitals such as Magnetic Resonance Imaging or Computed Tomography. A mono-static microwave head imaging system that can be carried in an ambulance for the detection and localization of intracranial haemorrhage is presented. The system employs a single ultra-wideband antenna as sensing element to transmit signals in low microwave frequencies towards the head and capture backscattered signals. The compact and low-profile antenna provides stable directional radiation patterns over the operating bandwidth in both near and far-fields. Numerical analysis of the head imaging system with a realistic head model in various situations is performed to realize the scattering mechanism of haemorrhage. A modified delay-and-summation back-projection algorithm, which includes effects of surface waves and a distance-dependent effective permittivity model, is proposed for signal and image post-processing. The efficacy of the automated head imaging system is evaluated using a 3D-printed human head phantom with frequency dispersive dielectric properties including emulated haemorrhages with different sizes located at different depths. Scattered signals are acquired with a compact transceiver in a mono-static circular scanning profile. The reconstructed images demonstrate that the system is capable of detecting haemorrhages as small as 1 cm3. While quantitative analyses reveal that the quality of images gradually degrades with the increase of the haemorrhage's depth due to the reduction of signal penetration inside the head; rigorous statistical analysis suggests that substantial improvement in image quality can be obtained by increasing the data samples collected around the head. The proposed head imaging prototype along with the processing algorithm demonstrates

  9. The role of indium-111 antimyosin (Fab) imaging as a noninvasive surveillance method of human heart transplant rejection

    International Nuclear Information System (INIS)

    De Nardo, D.; Scibilia, G.; Macchiarelli, A.G.

    1989-01-01

    The identification of rejection after heart transplantation in patients receiving cyclosporine immunosuppressive therapy requires the endomyocardial biopsy, an invasive method associated with a finite morbidity. To evaluate the role of indium-111 antimyosin (Fab) scintigraphy as a noninvasive surveillance method of heart transplant rejection, the Fab fragment of murine monoclonal antimyosin antibodies labeled with indium-111 was administered intravenously in 30 scintigraphic studies to 10 consecutive heart transplant recipients. Endomyocardial biopsy specimens were obtained 72 hours after each scintigraphic study. Nineteen scintigraphic studies had negative findings; no false negative finding was obtained. Eleven antimyosin scintigraphic studies had positive findings, and in these studies endomyocardial biopsy revealed mild rejection in two cases, moderate acute rejection with myocyte necrosis in two cases, myocyte necrosis as a consequence of ischemic injury in six cases, and possibly cytotoxic damage in one case. Antimyosin scintigraphy may represent a reliable screening method for the surveillance of heart transplant patients. In the presence of a negative finding from antimyosin scintigraphy, it may be possible to avoid endomyocardial biopsy. Conversely, in patients who have a positive finding from antimyosin scintigraphy, the endomyocardial biopsy is mandatory to establish the definitive diagnosis by histologic examination of the myocardium

  10. Noninvasive identification of subcellular organization and nuclear morphology features associated with leukemic cells using light-scattering spectroscopy

    Science.gov (United States)

    Hsiao, Austin; Hunter, Martin; Greiner, Cherry; Gupta, Sharad; Georgakoudi, Irene

    2011-03-01

    Leukemia is the most common and deadly cancer among children and one of the most prevalent cancers among adults. Improvements in its diagnosis and monitoring of leukemic patients could have a significant impact in their long-term treatment. We demonstrate that light-scattering spectroscopy (LSS)-based approaches could serve as a tool to achieve this goal. Specifically, we characterize the light scattering properties of leukemic (NALM-6) cells and compare them to those of normal lymphocytes and granulocytes in the 440-710 nm range, over +/-4 deg about the exact backscattering direction. We find that the LSS spectra are well described by an inverse power-law wavelength dependence, with a power exponent insensitive to the scattering angle but significantly higher for leukemic cells than for normal leukocytes. This is consistent with differences in the subcellular morphology of these cells, detected in differential interference contrast images. Furthermore, the residual light-scattering signal, extracted after subtracting the inverse power-law fit from the data, can be analyzed assuming a Gaussian distribution of spherical scatterers using Mie theory. This analysis yields scatterer sizes that are consistent with the diameters of cell nuclei and allows the detection of the larger nuclei of NALM-6 cells compared to those of lymphocytes and granulocytes.

  11. SU-E-J-96: Multi-Axis Dose Accumulation of Noninvasive Image-Guided Breast Brachytherapy Through Biomechanical Modeling of Tissue Deformation Using the Finite Element Method

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, MJ [Tufts University School of Medicine, Boston, MA (United States); Ghadyani, HR [SUNY Farmingdale State College, Farmingdale, NY (United States); Bastien, AD; Lutz, NN [Univeristy Massachusetts Lowell, Lowell, MA (United States); Hepel, JT [Rhode Island Hospital, Providence, RI (United States)

    2015-06-15

    Purpose: Noninvasive image-guided breast brachytherapy delivers conformal HDR Ir-192 brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. Methods: The model assumed the breast was under planar stress with values of 30 kPa for Young’s modulus and 0.3 for Poisson’s ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. Results: Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target-applicator combinations. Conclusions: The model exhibited skin dose trends that matched MC-generated benchmarking results and clinical measurements within 2% over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over

  12. SU-E-J-96: Multi-Axis Dose Accumulation of Noninvasive Image-Guided Breast Brachytherapy Through Biomechanical Modeling of Tissue Deformation Using the Finite Element Method

    International Nuclear Information System (INIS)

    Rivard, MJ; Ghadyani, HR; Bastien, AD; Lutz, NN; Hepel, JT

    2015-01-01

    Purpose: Noninvasive image-guided breast brachytherapy delivers conformal HDR Ir-192 brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. Methods: The model assumed the breast was under planar stress with values of 30 kPa for Young’s modulus and 0.3 for Poisson’s ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. Results: Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target-applicator combinations. Conclusions: The model exhibited skin dose trends that matched MC-generated benchmarking results and clinical measurements within 2% over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over

  13. New concepts in molecular imaging: non-invasive MRI spotting of proteolysis using an Overhauser effect switch.

    Directory of Open Access Journals (Sweden)

    Philippe Mellet

    Full Text Available Proteolysis, involved in many processes in living organisms, is tightly regulated in space and time under physiological conditions. However deregulation can occur with local persistent proteolytic activities, e.g. in inflammation, cystic fibrosis, tumors, or pancreatitis. Furthermore, little is known about the role of many proteases, hence there is a need of new imaging methods to visualize specifically normal or disease-related proteolysis in intact bodies.In this paper, a new concept for non invasive proteolysis imaging is proposed. Overhauser-enhanced Magnetic Resonance Imaging (OMRI at 0.2 Tesla was used to monitor the enzymatic hydrolysis of a nitroxide-labeled protein. In vitro, image intensity switched from 1 to 25 upon proteolysis due to the associated decrease in the motional correlation time of the substrate. The OMRI experimental device used in this study is consistent with protease imaging in mice at 0.2 T without significant heating. Simulations show that this enzymatic-driven OMRI signal switch can be obtained at lower frequencies suitable for larger animals or humans.The method is highly sensitive and makes possible proteolysis imaging in three dimensions with a good spatial resolution. Any protease could be targeted specifically through the use of taylor-made cleavable macromolecules. At short term OMRI of proteolysis may be applied to basic research as well as to evaluate therapeutic treatments in small animal models of experimental diseases.

  14. Medical imaging

    CERN Document Server

    Townsend, David W

    1996-01-01

    Since the introduction of the X-ray scanner into radiology almost 25 years ago, non-invasive imaging has become firmly established as an essential tool in the diagnosis of disease. Fully three-dimensional imaging of internal organs is now possible, b and for studies which explore the functional status of the body. Powerful techniques to correlate anatomy and function are available, and scanners which combine anatomical and functional imaging in a single device are under development. Such techniques have been made possible through r ecent technological and mathematical advances. This series of lectures will review both the physical basis of medical imaging techniques using X-rays, gamma and positron emitting radiosiotopes, and nuclear magnetic resonance, and the mathematical methods used to reconstruct three-dimentional distributions from projection data. The lectures will trace the development of medical imaging from simple radiographs to the present-day non-invasive measurement of in vivo biochemistry. They ...

  15. Nanocarriers for nuclear imaging and radiotherapy of cancer.

    Science.gov (United States)

    Mitra, Amitava; Nan, Anjan; Line, Bruce R; Ghandehari, Hamidreza

    2006-01-01

    Several nanoscale carriers (nanoparticles, liposomes, water-soluble polymers, micelles and dendrimers) have been developed for targeted delivery of cancer diagnostic and therapeutic agents. These carriers can selectively target cancer sites and carry large payloads, thereby improving cancer detection and therapy effectiveness. Further, the combination of newer nuclear imaging techniques providing high sensitivity and spatial resolution such as dual modality imaging with positron emission tomography/computed tomography (PET/CT) and use of nanoscale devices to carry diagnostic and therapeutic radionuclides with high target specificity can enable more accurate detection, staging and therapy planning of cancer. The successful clinical applications of radiolabeled monoclonal antibodies for cancer detection and therapy bode well for the future of nanoscale carrier systems in clinical oncology. Several radiolabeled multifunctional nanocarriers have been effective in detecting and treating cancer in animal models. Nonetheless, further preclinical, clinical and long-term toxicity studies will be required to translate this technology to the care of patients with cancer. The objective of this review is to present a brief but comprehensive overview of the various nuclear imaging techniques and the use of nanocarriers to deliver radionuclides for the diagnosis and therapy of cancer.

  16. An image analyzer system for the analysis of nuclear traces

    International Nuclear Information System (INIS)

    Cuapio O, A.

    1990-10-01

    Inside the project of nuclear traces and its application techniques to be applied in the detection of nuclear reactions of low section (non detectable by conventional methods), in the study of accidental and personal neutron dosemeters, and other but, are developed. All these studies are based on the fact that the charged particles leave latent traces of dielectric that if its are engraved with appropriate chemical solutions its are revealed until becoming visible to the optical microscope. From the analysis of the different trace forms, it is possible to obtain information of the characteristic parameters of the incident particles (charge, mass and energy). Of the density of traces it is possible to obtain information of the flow of the incident radiation and consequently of the received dose. For carry out this analysis has been designed and coupled different systems, that it has allowed the solution of diverse outlined problems. Notwithstanding it has been detected that to make but versatile this activity is necessary to have an Image Analyzer System that allow us to digitize, to process and to display the images with more rapidity. The present document, presents the proposal to carry out the acquisition of the necessary components for to assembling an Image Analyzing System, like support to the mentioned project. (Author)

  17. Nanotargeted Radionuclides for Cancer Nuclear Imaging and Internal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Gann Ting

    2010-01-01

    Full Text Available Current progress in nanomedicine has exploited the possibility of designing tumor-targeted nanocarriers being able to deliver radionuclide payloads in a site or molecular selective manner to improve the efficacy and safety of cancer imaging and therapy. Radionuclides of auger electron-, α-, β-, and γ-radiation emitters have been surface-bioconjugated or after-loaded in nanoparticles to improve the efficacy and reduce the toxicity of cancer imaging and therapy in preclinical and clinical studies. This article provides a brief overview of current status of applications, advantages, problems, up-to-date research and development, and future prospects of nanotargeted radionuclides in cancer nuclear imaging and radiotherapy. Passive and active nanotargeting delivery of radionuclides with illustrating examples for tumor imaging and therapy are reviewed and summarized. Research on combing different modes of selective delivery of radionuclides through nanocarriers targeted delivery for tumor imaging and therapy offers the new possibility of large increases in cancer diagnostic efficacy and therapeutic index. However, further efforts and challenges in preclinical and clinical efficacy and toxicity studies are required to translate those advanced technologies to the clinical applications for cancer patients.

  18. Nuclear Magnetic Resonance Imaging of Li-ion Battery

    Directory of Open Access Journals (Sweden)

    D. Ohno

    2010-12-01

    Full Text Available Nuclear magnetic resonance (NMR imaging has high sensitivity to proton (1H and lithium (7Li. It is a useful measurement for electrolyte in Li-ion battery. 1H NMR images of lithium ion battery which is composed of LiMn2O4 / LiClO4 + propylene carbonate (PC / Li-metal have been studied. 1H NMR images of electrolyte near cathode material (LiMn2O4 showed anomalous intensity distribution, which was quite inhomogeneous. From NMR images as a function of repetition time (TR, it was concluded that the anomalous intensity distribution was not due to change of relaxation time but an indirect (spatial para-magnetization effect from cathode material. The paramagnetization induced by high magnetic field distorts linearity of magnetic gradient field, leading to apparent intensity variance. This functional image is an easy diagnostic measurement for magnetization of cathode material, which allows the possibility to check uniformity of cathode material and change of magnetization under electrochemical process.

  19. Acoustic radiation force impulse-imaging and transient elastography for non-invasive assessment of liver fibrosis and steatosis in NAFLD

    International Nuclear Information System (INIS)

    Friedrich-Rust, Mireen; Romen, Daniela; Vermehren, Johannes; Kriener, Susanne; Sadet, Dilek; Herrmann, Eva; Zeuzem, Stefan; Bojunga, Joerg

    2012-01-01

    Background: Transient elastography (TE) and acoustic radiation force impulse (ARFI)-imaging have shown promising results for the staging of liver fibrosis. Aim: The aim of the present study was to compare ARFI of the left and right liver lobe with TE using the standard and obese probes for the diagnosis of liver fibrosis in NAFL/NASH. In addition, liver steatosis is evaluated using the novel controlled attenuation parameter (CAP). Methods: Sixty-one patients with NAFLD/NASH were included in the study. All patients received TE with both probes, ARFI of both liver lobes and CAP. The results were compared with liver histology. Results: 57 patients were included in the final analysis. The diagnostic accuracy for TE measurements with the M-and XL-probe and for ARFI of the right and left liver lobe was 0.73, 0.84, 0.71 and 0.60 for the diagnosis of severe fibrosis, and 0.93, 0.93, 0.74 and 0.90 for the diagnosis of cirrhosis, respectively. No significant difference of results was observed between TE and ARFI in the subgroup of patients with reliable TE-measurement when taking into account the best results of both methods. However, while a significant correlation could be found for TE with histological liver fibrosis, the correlation of ARFI with liver fibrosis was not statistically significant. A significant correlation was found for CAP with histological steatosis (r = 0.49, p < 0.001). Conclusions: No significant difference in diagnostic accuracy for the non-invasive assessment of liver fibrosis was found for transient elastography and ARFI. Nevertheless TE significantly correlated with liver fibrosis while ARFI did not. CAP enables the non-invasive assessment of steatosis.

  20. Non-invasive glucagon-like peptide-1 receptor imaging in pancreas with {sup 18}F-Al labeled Cys{sup 39}-exendin-4

    Energy Technology Data Exchange (ETDEWEB)

    Mi, Baoming [Department of Nuclear Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215006 (China); Department of Nuclear Medicine, Affiliated Hospital of Jiangnan University (Wuxi 4th People' s Hospital), Wuxi, Jiangsu, 214062 (China); Xu, Yuping [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu, 214063 (China); Nanjing Medical University, Nanjing, Jiangsu, 210029 (China); Pan, Donghui; Wang, Lizhen; Yang, Runlin [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu, 214063 (China); Yu, Chunjing; Wan, Weixing [Department of Nuclear Medicine, Affiliated Hospital of Jiangnan University (Wuxi 4th People' s Hospital), Wuxi, Jiangsu, 214062 (China); Wu, Yiwei, E-mail: wuyiwei3988@gmail.com [Department of Nuclear Medicine, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215006 (China); Yang, Min, E-mail: ymzfk@yahoo.com.hk [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi, Jiangsu, 214063 (China); Nanjing Medical University, Nanjing, Jiangsu, 210029 (China)

    2016-02-26

    Purpose: Glucagon-like peptide-1 receptor (GLP-1R) is abundantly expressed on beta cells and may be an ideal target for the pancreas imaging. Monitoring the GLP-1R of pancreas could be benefit for understanding the pathophysiology of diabetes. In the present study, {sup 18}F-Al labeled exendin-4 analog, {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4, was evaluated for PET imaging GLP-1R in the pancreas. Methods: The targeting of {sup 18}F-Al labeled exendin-4 analog was examined in healthy and streptozotocin induced diabetic rats. Rats were injected with {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4 and microPET imaging was performed at 1 h postinjection, followed by ex vivo biodistribution. GLP-1R expression in pancreas was determined through post mortern examinations. Results: The pancreas of healthy rats was readily visualized after administration of {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4, whereas the pancreas of diabetic rats, as well as those from rats co-injected with excess of unlabeled peptides, was barely visible by microPET. At 60 min postinjection, the pancreatic uptakes were 1.02 ± 0.15%ID/g and 0.23 ± 0.05%ID/g in healthy and diabetic rats respectively. Under block, the pancreatic uptakes of non-diabetic rats reduced to 0.21 ± 0.07%ID/g at the same time point. Biodistribution data and IHC staining confirmed the findings of the microPET imaging. Conclusion: The favorable preclinical data indicated that {sup 18}F-Al-NOTA-MAL-Cys{sup 39}-exendin-4may be suitable for non-invasive monitoring functional pancreatic beta cells.

  1. Non-invasive glucagon-like peptide-1 receptor imaging in pancreas with (18)F-Al labeled Cys(39)-exendin-4.

    Science.gov (United States)

    Mi, Baoming; Xu, Yuping; Pan, Donghui; Wang, Lizhen; Yang, Runlin; Yu, Chunjing; Wan, Weixing; Wu, Yiwei; Yang, Min

    2016-02-26

    Glucagon-like peptide-1 receptor (GLP-1R) is abundantly expressed on beta cells and may be an ideal target for the pancreas imaging. Monitoring the GLP-1R of pancreas could be benefit for understanding the pathophysiology of diabetes. In the present study, (18)F-Al labeled exendin-4 analog, (18)F-Al-NOTA-MAL-Cys(39)-exendin-4, was evaluated for PET imaging GLP-1R in the pancreas. The targeting of (18)F-Al labeled exendin-4 analog was examined in healthy and streptozotocin induced diabetic rats. Rats were injected with (18)F-Al-NOTA-MAL-Cys(39)-exendin-4 and microPET imaging was performed at 1 h postinjection, followed by ex vivo biodistribution. GLP-1R expression in pancreas was determined through post mortern examinations. The pancreas of healthy rats was readily visualized after administration of (18)F-Al-NOTA-MAL-Cys(39)-exendin-4, whereas the pancreas of diabetic rats, as well as those from rats co-injected with excess of unlabeled peptides, was barely visible by microPET. At 60 min postinjection, the pancreatic uptakes were 1.02 ± 0.15%ID/g and 0.23 ± 0.05%ID/g in healthy and diabetic rats respectively. Under block, the pancreatic uptakes of non-diabetic rats reduced to 0.21 ± 0.07%ID/g at the same time point. Biodistribution data and IHC staining confirmed the findings of the microPET imaging. The favorable preclinical data indicated that (18)F-Al-NOTA-MAL-Cys(39)-exendin-4may be suitable for non-invasive monitoring functional pancreatic beta cells. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. EPR oxygen imaging and hyperpolarized 13C MRI of pyruvate metabolism as non-invasive biomarkers of tumor treatment response to a glycolysis inhibitor 3-bromopyruvate

    Science.gov (United States)

    Matsumoto, Shingo; Saito, Keita; Yasui, Hironobu; Morris, H. Douglas; Munasinghe, Jeeva P.; Lizak, Martin; Merkle, Hellmut; Ardenkjaer-Larsen, Jan Henrik; Choudhuri, Rajani; Devasahayam, Nallathamby; Subramanian, Sankaran; Koretsky, Alan P.; Mitchell, James B.; Krishna, Murali C.

    2012-01-01

    The hypoxic nature of tumors results in treatment resistance and poor prognosis. To spare limited oxygen for more crucial pathways, hypoxic cancerous cells suppress mitochondrial oxidative phosphorylation, and promote glycolysis for energy production. Thereby, inhibition of glycolysis has the potential to overcome treatment resistance of hypoxic tumors. Here, EPR imaging was used to evaluate oxygen dependent efficacy on hypoxia-sensitive drug. The small molecule 3-bromopyruvate (3-BP) blocks glycolysis pathway by inhibiting hypoxia inducible enzymes, and enhanced cytotoxicity of 3-BP under hypoxic conditions has been reported in vitro. However, the efficacy of 3-BP was substantially attenuated in hypoxic tumor regions (pO2 < 10 mmHg) in vivo using squamous cell carcinoma (SCCVII)-bearing mouse model. Metabolic MRI studies using hyperpolarized 13C-labeled pyruvate showed that monocarboxylate transporter-1 (MCT1) is the major transporter for pyruvate and the analog 3-BP in SCCVII tumor. The discrepant results between in vitro and in vivo data were attributed to biphasic oxygen dependent expression of MCT1 in vivo. Expression of MCT1 was enhanced in moderately hypoxic (8–15 mmHg) tumor regions, but down regulated in severely hypoxic (< 5 mmHg) tumor regions. These results emphasize the importance of non-invasive imaging biomarkers to confirm the action of hypoxia-activated drugs. PMID:22692861

  3. EPR oxygen imaging and hyperpolarized 13C MRI of pyruvate metabolism as noninvasive biomarkers of tumor treatment response to a glycolysis inhibitor 3-bromopyruvate.

    Science.gov (United States)

    Matsumoto, Shingo; Saito, Keita; Yasui, Hironobu; Morris, H Douglas; Munasinghe, Jeeva P; Lizak, Martin; Merkle, Hellmut; Ardenkjaer-Larsen, Jan Henrik; Choudhuri, Rajani; Devasahayam, Nallathamby; Subramanian, Sankaran; Koretsky, Alan P; Mitchell, James B; Krishna, Murali C

    2013-05-01

    The hypoxic nature of tumors results in treatment resistance and poor prognosis. To spare limited oxygen for more crucial pathways, hypoxic cancerous cells suppress mitochondrial oxidative phosphorylation and promote glycolysis for energy production. Thereby, inhibition of glycolysis has the potential to overcome treatment resistance of hypoxic tumors. Here, EPR imaging was used to evaluate oxygen dependent efficacy on hypoxia-sensitive drug. The small molecule 3-bromopyruvate blocks glycolysis pathway by inhibiting hypoxia inducible enzymes and enhanced cytotoxicity of 3-bromopyruvate under hypoxic conditions has been reported in vitro. However, the efficacy of 3-bromopyruvate was substantially attenuated in hypoxic tumor regions (pO23-bromopyruvate in SCCVII tumor. The discrepant results between in vitro and in vivo data were attributed to biphasic oxygen dependent expression of monocarboxylate transporter-1 in vivo. Expression of monocarboxylate transporter-1 was enhanced in moderately hypoxic (8-15 mmHg) tumor regions but down regulated in severely hypoxic (<5 mmHg) tumor regions. These results emphasize the importance of noninvasive imaging biomarkers to confirm the action of hypoxia-activated drugs. Copyright © 2012 Wiley Periodicals, Inc.

  4. Synthesis of magnetic resonance–, X-ray– and ultrasound-visible alginate microcapsules for immunoisolation and noninvasive imaging of cellular therapeutics

    Science.gov (United States)

    Barnett, Brad P; Arepally, Aravind; Stuber, Matthias; Arifin, Dian R; Kraitchman, Dara L; Bulte, Jeff W M

    2011-01-01

    Cell therapy has the potential to treat or cure a wide variety of diseases. Non-invasive cell tracking techniques are, however, necessary to translate this approach to the clinical setting. This protocol details methods to create microcapsules that are visible by X-ray, ultrasound (US ) or magnetic resonance (MR) for the encapsulation and immunoisolation of cellular therapeutics. Three steps are generally used to encapsulate cellular therapeutics in an alginate matrix: (i) droplets of cell-containing liquid alginate are extruded, using an electrostatic generator, through a needle tip into a solution containing a dissolved divalent cation salt to form a solid gel; (ii) the resulting gelled spheres are coated with polycations as a cross-linker; and (iii) these complexes are then incubated in a second solution of alginate to form a semipermeable membrane composed of an inner and an outer layer of alginate. The microcapsules can be rendered visible during the first step by adding contrast agents to the primary alginate layer. Such contrast agents include superparamagnetic iron oxide for detection by 1H MR imaging (MRI); the radiopaque agents barium or bismuth sulfate for detection by X-ray modalities; or perfluorocarbon emulsions for multimodal detection by 19F MRI, X-ray and US imaging. The entire synthesis can be completed within 2 h. PMID:21799484

  5. Noninvasive imaging of protein-protein interactions from live cells and living subjects using bioluminescence resonance energy transfer.

    Science.gov (United States)

    De, Abhijit; Gambhir, Sanjiv Sam

    2005-12-01

    This study demonstrates a significant advancement of imaging of a distance-dependent physical process, known as the bioluminescent resonance energy transfer (BRET2) signal in living subjects, by using a cooled charge-coupled device (CCD) camera. A CCD camera-based spectral imaging strategy enables simultaneous visualization and quantitation of BRET signal from live cells and cells implanted in living mice. We used the BRET2 system, which utilizes Renilla luciferase (hRluc) protein and its substrate DeepBlueC (DBC) as an energy donor and a mutant green fluorescent protein (GFP2) as the acceptor. To accomplish this objective in this proof-of-principle study, the donor and acceptor proteins were fused to FKBP12 and FRB, respectively, which are known to interact only in the presence of the small molecule mediator rapamycin. Mammalian cells expressing these fusion constructs were imaged using a cooled-CCD camera either directly from culture dishes or by implanting them into mice. By comparing the emission photon yields in the presence and absence of rapamycin, the specific BRET signal was determined. The CCD imaging approach of BRET signal is particularly appealing due to its capacity to seamlessly bridge the gap between in vitro and in vivo studies. This work validates BRET as a powerful tool for interrogating and observing protein-protein interactions directly at limited depths in living mice.

  6. Bioluminescence : the potential of a non-invasive bio-optical imaging technique and improvement of animal research

    NARCIS (Netherlands)

    Hesselink, J. W.; van Dam, G. M.

    2007-01-01

    Bioluminescence is an optical imaging technique that exploits the emission of photons at specific wavelengths based on energy-dependent reactions catalysed by luciferases. The technique makes it possible to monitor measure, and track biological processes in living animals. A short review is

  7. An efficient and cost effective nuclear medicine image network

    International Nuclear Information System (INIS)

    Sampathkumaran, K.S.; Miller, T.R.

    1987-01-01

    An image network that is in use in a large nuclear medicine department is described. This network was designed to efficiently handle a large volume of clinical data at reasonable cost. Small, limited function computers are attached to each scintillation camera for data acquisition. The images are transferred by cable network or floppy disc to a large, powerful central computer for processing and display. Cost is minimized by use of small acquisition computers not equipped with expensive video display systems or elaborate analysis software. Thus, financial expenditure can be concentrated in a powerful central computer providing a centralized data base, rapid processing, and an efficient environment for program development. Clinical work is greatly facilitated because the physicians can process and display all studies without leaving the main reading area. (orig.)

  8. Nuclear magnetic resonance imaging characteristics of gallstones in vitro

    International Nuclear Information System (INIS)

    Moon, K.L. Jr.; Hricak, H.; Margulis, A.R.; Bernhoft, R.; Way, L.W.; Filly, R.A.; Crooks, L.E.

    1983-01-01

    The nuclear magnetic resonance (NMR) imaging characteristics of gallstones of various composition from 36 patients were studied in vitro using a spin-echo imaging technique. The majority of gallstones (83%) produced no measurable NMR signal despite having a mean water content of 12% and a mean cholesterol content of 61%. Six (17%) of the stones had a weak but measurable signal in the center of the stone, which was thought to represent signal from water in clefts or pores within the stones. The mean water and cholesterol content of the stones with measurable signal did not differ significantly from that of stones with no signal. A possible explanation for these findings, based on the known NMR characteristics of solid materials, is offered

  9. Advancing Precision Nuclear Medicine and Molecular Imaging for Lymphoma.

    Science.gov (United States)

    Wright, Chadwick L; Maly, Joseph J; Zhang, Jun; Knopp, Michael V

    2017-01-01

    PET with fluorodeoxyglucose F 18 ( 18 F FDG-PET) is a meaningful biomarker for the detection, targeted biopsy, and treatment of lymphoma. This article reviews the evolution of 18 F FDG-PET as a putative biomarker for lymphoma and addresses the current capabilities, challenges, and opportunities to enable precision medicine practices for lymphoma. Precision nuclear medicine is driven by new imaging technologies and methodologies to more accurately detect malignant disease. Although quantitative assessment of response is limited, such technologies will enable a more precise metabolic mapping with much higher definition image detail and thus may make it a robust and valid quantitative response assessment methodology. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Various dedicated imaging systems for routine nuclear medical applications

    International Nuclear Information System (INIS)

    Bela Kari; Tamas Gyorke; Erno Mako; Laszlo Nagy; Jozsef Turak; Oszkar Partos

    2004-01-01

    The most essential problems of nuclear medical imaging are resolution, signal/noise ratio (S/N) and sensitivity. Nowadays, the vast majority of the Anger system gamma cameras in clinical application are using parallel projection. The main problem of this projection method is the highly dependence of the image quality on the distance from the collimator surface as well as any improvement in the resolution with the distance -i.e. reduction of image blur- significantly reduces sensitivity. The aim of our research and development work was to create imaging geometry, collimator and detector constructions optimized to particular organs (brain, heart, thyroid), where it is simultaneously possible to increase the resolution and sensitivity. Main concept of the imaging geometry construction is based on the size, location and shape of a particular organ. In case of brain SPECT imaging a multiple head (4 heads in cylinder symmetric approximation) arrangement with extra high intrinsic resolution (<2.5 mm) dedicated detector design provide feasible solution for routine clinical application. The imaging system was essentially designed for Tc-99m and I-123 isotopes. The application field can be easily extended for functional small animal research and new born baby studies. Very positive feedbacks were received from both technical (stability and reproducibility of the technical parameters) and clinical sides in the past 2 years routine applications. A unique, novel conception ultra compact dedicated dual head SPECT system has been created only for 2D, 3D nuclear cardiac applications for Tc-99m and T1-201 labeled radio-pharmaceuticals. The two rectangular detectors (with <2.6 mm intrinsic resolution) are mounted fix in 90 degree geometry and move inside the special formed gantry arrangement. The unique and unusual gantry is designed to keep the detector heads as close as possible to the patient, while the patient is not exposed by any moving part. This special construction also

  11. Work in progress: nuclear magnetic resonance imaging of the gallbladder

    International Nuclear Information System (INIS)

    Hricak, H.; Filly, R.A.; Margulis, A.R.; Moon, K.L.; Crooks, L.E.; Kaufman, L.

    1983-01-01

    A preliminary study of the relation between food intake and intensity of gallbladder bile on nuclear magnetic resonance (NMR) images was made. Twelve subjects (seven volunteers, five patients) were imaged following a minimum of 14 hours of fasting. Six of seven volunteers were reimaged one hour after stimulation by either a fatty meal or an alcoholic beverage. An additional seven patients were imaged two hours after a hospital breakfast. It was found that concentrated bile emits a high-intensity spin echo signal (SE), while hepatic bile in the gallbladder produces a low-intensity SE signal. Following ingestion of cholecystogogue, dilute hepatic bile settles on top of the concentrated bile, each emitting SE signals of different intensity. The average T1 value of concentrated bile was 594 msec, while the T1 vaue of dilute hepatic bile was 2,646 msec. The average T2 values were 104 msec for concentrated bile and 126 msec for dilute bile. The most likely cause for the different SE intensities of bile is the higher water content, and therefore longer T1 or T2 relaxation times, of hepatic bile. It is suggested that NMR imaging has the ability to provide physiological information about the gallbladder and that it may prove to be a simple and safe clinical test of gallbladder function

  12. Brief review of image reconstruction methods for imaging in nuclear medicine

    International Nuclear Information System (INIS)

    Murayama, Hideo

    1999-01-01

    Emission computed tomography (ECT) has as its major emphasis the quantitative determination of the moment to moment changes in the chemistry and flow physiology of injected or inhaled compounds labeled with radioactive atoms in a human body. The major difference lies in the fact that ECT seeks to describe the location and intensity of sources of emitted photons in an attenuating medium whereas transmission X-ray computed tomography (TCT) seeks to determine the distribution of the attenuating medium. A second important difference between ECT and TCT is that of available statistics. ECT statistics are low because each photon without control in emitting direction must be detected and analyzed, not as in TCT. The following sections review the historical development of image reconstruction methods for imaging in nuclear medicine, relevant intrinsic concepts for image reconstruction on ECT, and current status of volume imaging as well as a unique approach on iterative techniques for ECT. (author). 130 refs

  13. Noninvasive near infrared autofluorescence imaging of retinal pigment epithelial cells in the human retina using adaptive optics.

    Science.gov (United States)

    Liu, Tao; Jung, HaeWon; Liu, Jianfei; Droettboom, Michael; Tam, Johnny

    2017-10-01

    The retinal pigment epithelial (RPE) cells contain intrinsic fluorophores that can be visualized using infrared autofluorescence (IRAF). Although IRAF is routinely utilized in the clinic for visualizing retinal health and disease, currently, it is not possible to discern cellular details using IRAF due to limits in resolution. We demonstrate that the combination of adaptive optics (AO) with IRAF (AO-IRAF) enables higher-resolution imaging of the IRAF signal, revealing the RPE mosaic in the living human eye. Quantitative analysis of visualized RPE cells in 10 healthy subjects across various eccentricities demonstrates the possibility for in vivo density measurements of RPE cells, which range from 6505 to 5388 cells/mm 2 for the areas measured (peaking at the fovea). We also identified cone photoreceptors in relation to underlying RPE cells, and found that RPE cells support on average up to 18.74 cone photoreceptors in the fovea down to an average of 1.03 cone photoreceptors per RPE cell at an eccentricity of 6 mm. Clinical application of AO-IRAF to a patient with retinitis pigmentosa illustrates the potential for AO-IRAF imaging to become a valuable complementary approach to the current landscape of high resolution imaging modalities.

  14. Non-invasive detection of the early phase of kidney injury by photoacoustic/computed tomography imaging

    Science.gov (United States)

    Pan, Wanma; Peng, Wen; Ning, Fengling; Zhang, Yu; Zhang, Yunfei; Wang, Yinhang; Xie, Weiyi; Zhang, Jing; Xin, Hong; Li, Cong; Zhang, Xuemei

    2018-06-01

    The early diagnosis of kidney diseases, which can remarkably impair the quality of life and are costly, has encountered great difficulties. Therefore, the development of methods for early diagnosis has great clinical significance. In this study, we used an emerging technique of photoacoustic (PA) imaging, which has relatively high spatial resolution and good imaging depth. Two kinds of PA gold nanoparticle (GNP)-based bioprobes were developed based on their superior photo detectability, size controllability and biocompatibility. The kidney injury mouse model was developed by unilateral ureteral obstruction for 96 h and the release of obstruction model). Giving 3.5 and 5.5 nm bioprobes by tail vein injection, we found that the 5.5 nm probe could be detected in the bladder in the model group, but not in the control group. These results were confirmed by computed tomography imaging. Furthermore, the model group did not show changes in the blood biochemical indices (BUN and Scr) and histologic examination. The 5.5 nm GNPs were found to be the critical point for early diagnosis of kidney injury. This new method was faster and more sensitive and accurate for the detection of renal injury, compared with conventional methods, and can be used for the development of a PA GNP-based bioprobe for diagnosing renal injury.

  15. Noninvasive coronary artery imaging by multislice spiral computed tomography. A novel approach for a retrospectively ECG-gated reconstruction technique

    International Nuclear Information System (INIS)

    Sato, Yuichi; Kanmatsuse, Katsuo; Inoue Fumio

    2003-01-01

    Although the excellent spatial resolution of multislice spiral computed tomography (MSCT) enables the coronary arteries to be visualized, its limited temporal resolution results in poor image reproducibility because of cardiac motion artifact (CMA) and hence limits its widespread clinical use. A novel retrospectively electrocardiogram (ECG)-gated reconstruction method has been developed to minimize CMA. In 88 consecutive patients, the scan data were reconstructed using 2 retrospectively ECG-gated reconstruction methods. Method 1: the end of the reconstruction window (250 ms) was positioned at the peak of the P wave on ECG, which corresponded to the end of the slow filling phase during diastole immediately before atrial contraction. Method 2 (conventional method): relative retrospective gating with 50% referred to the R-R interval was performed so that the beginning of the reconstruction window (250 ms) was positioned at the halfway point between the R-R intervals of the heart cycle. The quality of the coronary artery images was evaluated according to the presence or absence of CMA. The assessment was applied to the left main coronary artery (LMCA), the left anterior descending artery (LAD, segments no.6, no.7, and no.8), the left circumflex artery (LCx, segments no.11 and no.13) and the right coronary artery (RCA, segments no.1, no.2 and no.3). The first diagonal artery (no.9-1), the obtuse marginal artery (no.12-1), the posterior descending artery (no.4-PD), the atrioventricular node branch (no.4-AV) and the first right ventricular branch (RV) were also evaluated. Of the 88 patients, 85 were eligible for image evaluation. Method 1 allowed visualization of the major coronary arteries without CMA in the majority of patients. The left coronary artery (LCA) system (segments no.5-7, no.11 and no.13) and the proximal portion of the RCA were visualized in more than 94% of patients. Artifact-free visualization of the distal portion of the LAD (segment no.8) and RCA (no.4

  16. A semi-automated method for non-invasive internal organ weight estimation by post-mortem magnetic resonance imaging in fetuses, newborns and children

    International Nuclear Information System (INIS)

    Thayyil, Sudhin; Schievano, Silvia; Robertson, Nicola J.; Jones, Rodney; Chitty, Lyn S.; Sebire, Neil J.; Taylor, Andrew M.

    2009-01-01

    Magnetic resonance (MR) imaging allows minimally invasive autopsy, especially when consent is declined for traditional autopsy. Estimation of individual visceral organ weights is an important component of traditional autopsy. Objective: To examine whether a semi-automated can be used for non-invasive internal organ weight measurement using post-mortem MR imaging in fetuses, newborns and children. Methods: Phase 1: In vitro scanning of 36 animal organs (heart, liver, kidneys) was performed to check the accuracy of volume reconstruction methodology. Real volumes were measured by water displacement method. Phase 2: Sixty-five whole body post-mortem MR scans were performed in fetuses (n = 30), newborns (n = 5) and children (n = 30) at 1.5 T using a 3D TSE T2-weighted sequence. These data were analysed offline using the image processing software Mimics 11.0. Results: Phase 1: Mean difference (S.D.) between estimated and actual volumes were -0.3 (1.5) ml for kidney, -0.7 (1.3) ml for heart, -1.7 (3.6) ml for liver in animal experiments. Phase 2: In fetuses, newborns and children mean differences between estimated and actual weights (S.D.) were -0.6 (4.9) g for liver, -5.1 (1.2) g for spleen, -0.3 (0.6) g for adrenals, 0.4 (1.6) g for thymus, 0.9 (2.5) g for heart, -0.7 (2.4) g for kidneys and 2.7 (14) g for lungs. Excellent co-correlation was noted for estimated and actual weights (r 2 = 0.99, p < 0.001). Accuracy was lower when fetuses were less than 20 weeks or less than 300 g. Conclusion: Rapid, accurate and reproducible estimation of solid internal organ weights is feasible using the semi-automated 3D volume reconstruction method.

  17. Non-invasive assessment of intratumoral vascularity using arterial spin labeling: A comparison to susceptibility-weighted imaging for the differentiation of primary cerebral lymphoma and glioblastoma

    International Nuclear Information System (INIS)

    Furtner, J.; Schöpf, V.; Preusser, M.; Asenbaum, U.; Woitek, R.; Wöhrer, A.; Hainfellner, J.A.; Wolfsberger, S.; Prayer, D.

    2014-01-01

    Using conventional MRI methods, the differentiation of primary cerebral lymphomas (PCNSL) and other primary brain tumors, such as glioblastomas, is difficult due to overlapping imaging characteristics. This study was designed to discriminate tumor entities using normalized vascular intratumoral signal intensity values (nVITS) obtained from pulsed arterial spin labeling (PASL), combined with intratumoral susceptibility signals (ITSS) from susceptibility-weighted imaging (SWI). Thirty consecutive patients with glioblastoma (n = 22) and PCNSL (n = 8), histologically classified according to the WHO brain tumor classification, were included. MRIs were acquired on a 3 T scanner, and included PASL and SWI sequences. nVITS was defined by the signal intensity ratio between the tumor and the contralateral normal brain tissue, as obtained by PASL images. ITSS was determined as intratumoral low signal intensity structures detected on SWI sequences and were divided into four different grades. Potential differences in the nVITS and ITSS between glioblastomas and PCNSLs were revealed using statistical testing. To determine sensitivity, specificity, and diagnostic accuracy, as well as an optimum cut-off value for the differentiation of PCNSL and glioblastoma, a receiver operating characteristic analysis was used. We found that nVITS (p = 0.011) and ITSS (p = 0.001) values were significantly higher in glioblastoma than in PCNSL. The optimal cut-off value for nVITS was 1.41 and 1.5 for ITSS, with a sensitivity, specificity, and accuracy of more than 95%. These findings indicate that nVITS values have a comparable diagnostic accuracy to ITSS values in differentiating glioblastoma and PCNSL, offering a completely non-invasive and fast assessment of tumoral vascularity in a clinical setting

  18. Non-invasive assessment of intratumoral vascularity using arterial spin labeling: A comparison to susceptibility-weighted imaging for the differentiation of primary cerebral lymphoma and glioblastoma.

    Science.gov (United States)

    Furtner, J; Schöpf, V; Preusser, M; Asenbaum, U; Woitek, R; Wöhrer, A; Hainfellner, J A; Wolfsberger, S; Prayer, D

    2014-05-01

    Using conventional MRI methods, the differentiation of primary cerebral lymphomas (PCNSL) and other primary brain tumors, such as glioblastomas, is difficult due to overlapping imaging characteristics. This study was designed to discriminate tumor entities using normalized vascular intratumoral signal intensity values (nVITS) obtained from pulsed arterial spin labeling (PASL), combined with intratumoral susceptibility signals (ITSS) from susceptibility-weighted imaging (SWI). Thirty consecutive patients with glioblastoma (n=22) and PCNSL (n=8), histologically classified according to the WHO brain tumor classification, were included. MRIs were acquired on a 3T scanner, and included PASL and SWI sequences. nVITS was defined by the signal intensity ratio between the tumor and the contralateral normal brain tissue, as obtained by PASL images. ITSS was determined as intratumoral low signal intensity structures detected on SWI sequences and were divided into four different grades. Potential differences in the nVITS and ITSS between glioblastomas and PCNSLs were revealed using statistical testing. To determine sensitivity, specificity, and diagnostic accuracy, as well as an optimum cut-off value for the differentiation of PCNSL and glioblastoma, a receiver operating characteristic analysis was used. We found that nVITS (p=0.011) and ITSS (p=0.001) values were significantly higher in glioblastoma than in PCNSL. The optimal cut-off value for nVITS was 1.41 and 1.5 for ITSS, with a sensitivity, specificity, and accuracy of more than 95%. These findings indicate that nVITS values have a comparable diagnostic accuracy to ITSS values in differentiating glioblastoma and PCNSL, offering a completely non-invasive and fast assessment of tumoral vascularity in a clinical setting. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Non-invasive assessment of intratumoral vascularity using arterial spin labeling: A comparison to susceptibility-weighted imaging for the differentiation of primary cerebral lymphoma and glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Furtner, J., E-mail: julia.furtner@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Schöpf, V., E-mail: veronika.schoepf@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Preusser, M., E-mail: matthias.preusser@meduniwien.ac.at [Department of Medicine I, Division of Oncology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Asenbaum, U., E-mail: ulrika.asenbaum@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Woitek, R., E-mail: ramona.woitek@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Wöhrer, A., E-mail: adelheid.woehrer@meduniwien.ac.at [Institute of Neurology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Hainfellner, J.A., E-mail: johannes.hainfellner@meduniwien.ac.at [Institute of Neurology, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Wolfsberger, S., E-mail: stefan.wolfsberger@meduniwien.ac.at [Department of Neurosurgery, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria); Prayer, D., E-mail: daniela.prayer@meduniwien.ac.at [Department of Biomedical Imaging und Image-guided Therapy, Medical University of Vienna (Austria); Comprehensive Cancer Center-Central Nervous System Tumors Unit (CCC-CNS), Medical University of Vienna (Austria)

    2014-05-15

    Using conventional MRI methods, the differentiation of primary cerebral lymphomas (PCNSL) and other primary brain tumors, such as glioblastomas, is difficult due to overlapping imaging characteristics. This study was designed to discriminate tumor entities using normalized vascular intratumoral signal intensity values (nVITS) obtained from pulsed arterial spin labeling (PASL), combined with intratumoral susceptibility signals (ITSS) from susceptibility-weighted imaging (SWI). Thirty consecutive patients with glioblastoma (n = 22) and PCNSL (n = 8), histologically classified according to the WHO brain tumor classification, were included. MRIs were acquired on a 3 T scanner, and included PASL and SWI sequences. nVITS was defined by the signal intensity ratio between the tumor and the contralateral normal brain tissue, as obtained by PASL images. ITSS was determined as intratumoral low signal intensity structures detected on SWI sequences and were divided into four different grades. Potential differences in the nVITS and ITSS between glioblastomas and PCNSLs were revealed using statistical testing. To determine sensitivity, specificity, and diagnostic accuracy, as well as an optimum cut-off value for the differentiation of PCNSL and glioblastoma, a receiver operating characteristic analysis was used. We found that nVITS (p = 0.011) and ITSS (p = 0.001) values were significantly higher in glioblastoma than in PCNSL. The optimal cut-off value for nVITS was 1.41 and 1.5 for ITSS, with a sensitivity, specificity, and accuracy of more than 95%. These findings indicate that nVITS values have a comparable diagnostic accuracy to ITSS values in differentiating glioblastoma and PCNSL, offering a completely non-invasive and fast assessment of tumoral vascularity in a clinical setting.

  20. Non-invasive grading of brain tumours using dynamic amino acid PET imaging: does it work for 11C-Methionine?

    International Nuclear Information System (INIS)

    Moulin-Romsee, Gerard; D'Hondt, Eduard; Mortelmans, Luc; Laere, Koen van; Groot, Tjibbe de; Goffin, Jan; Sciot, Raf; Menten, Johan; Bormans, Guy

    2007-01-01

    Static imaging of amino acids does not allow differentiation of low versus high grade brain tumours. It has been shown that dynamic imaging of the amino acid analogue 18 F-fluoroethyltyrosine (FET) can achieve this goal. In many centres, 11 C-methionine (MET) is used for tumour imaging, but no clinical studies on the use of dynamic scanning for grading have been performed. Thirty-four patients with primary brain glioma and histopathological confirmation were retrospectively studied using 40 min dynamic MET-PET with 220 MBq 11C-methionine. In relation to histopathological grading, various metabolic indices and temporal parameters as documented by Poepperl et al. (JNM 2006;47:393-403) were analyzed. None of the evaluated static or temporal parameters allowed discrimination between high and low grade tumours. On average, low grade tumours showed washout after the initial uptake maximum, while both increases and decreases were seen for high grade tumours. Only the relative early versus late uptake ratio showed a trend towards significance (-0.16 ± 0.17 for low grade versus 0.01 ± 0.25 for high grade; p = 0.07). Unlike FET-PET, the uptake characteristics of MET-PET do not allow classification of low and high grade tumours on an individual patient basis. Since literature data indicate that both tracers have a similar performance regarding biopsy location, tumour delineation, and detection of recurrence, FET-PET should be advocated over MET-PET as its uptake mechanism also allows noninvasive grading in glioma. (orig.)

  1. Improved computer-assisted nuclear imaging in renovascular hypertension

    International Nuclear Information System (INIS)

    Gross, M.L.; Nally, J.V.; Potvini, W.J.; Clarke, H.S. Jr.; Higgins, J.T.; Windham, J.P.

    1985-01-01

    A computer-assisted program with digital background subtraction has been developed to analyze the initial 90 second Tc-99m DTPA renal flow scans in an attempt to quantitate the early isotope delivery to and uptake by the kidney. This study was designed to compare the computer-assisted 90 second DTPA scan with the conventional 30 minute I-131 Hippuran scan. Six patients with angiographically-proven unilateral renal artery stenosis were studied. The time activity curves for both studies were derived from regions of interest selected from the computer acquired dynamic images. The following parameters were used to assess renal blood flow: differential maximum activity, minimum/maximum activity ratio, and peak width. The computer-assisted DTPA study accurately predicted (6/6) the stenosed side documented angiographically, whereas the conventional Hippuran scan was clearly predictive in only 2/6. In selected cases successfully corrected surgically, the DTPA study proved superior in assessing the degree of patency of the graft. The best discriminatory factors when compared to a template synthesized from curves obtained from normal subjects were differential maximum activity and peak width. The authors conclude that: 1) the computer-assisted 90 second DTPA renal blood flow scan was superior to the conventional I-131 Hippuran scan in demonstrating unilateral reno-vascular disease; 2) the DTPA study was highly predictive of the angiographic findings; and 3) this non-invasive study should prove useful in the diagnosis and serial evaluation following surgery and/or angioplasty for renal artery stenosis

  2. Uncovering Special Nuclear Materials by Low-energy Nuclear Reaction Imaging.

    Science.gov (United States)

    Rose, P B; Erickson, A S; Mayer, M; Nattress, J; Jovanovic, I

    2016-04-18

    Weapons-grade uranium and plutonium could be used as nuclear explosives with extreme destructive potential. The problem of their detection, especially in standard cargo containers during transit, has been described as "searching for a needle in a haystack" because of the inherently low rate of spontaneous emission of characteristic penetrating radiation and the ease of its shielding. Currently, the only practical approach for uncovering well-shielded special nuclear materials is by use of active interrogation using an external radiation source. However, the similarity of these materials to shielding and the required radiation doses that may exceed regulatory limits prevent this method from being widely used in practice. We introduce a low-dose active detection technique, referred to as low-energy nuclear reaction imaging, which exploits the physics of interactions of multi-MeV monoenergetic photons and neutrons to simultaneously measure the material's areal density and effective atomic number, while confirming the presence of fissionable materials by observing the beta-delayed neutron emission. For the first time, we demonstrate identification and imaging of uranium with this novel technique using a simple yet robust source, setting the stage for its wide adoption in security applications.

  3. Diffusion-weighted magnetic resonance imaging: a potential non-invasive marker of tumour aggressiveness in localized prostate cancer

    International Nuclear Information System (INIS)

    Souza, N.M. de; Riches, S.F.; Van As, N.J.; Morgan, V.A.; Ashley, S.A.; Fisher, C.; Payne, G.S.; Parker, C.

    2008-01-01

    Aim: To evaluate diffusion-weighted magnetic resonance imaging (DW-MRI) as a marker for disease aggressiveness by comparing tumour apparent diffusion coefficients (ADCs) between patients with low- versus higher-risk localized prostate cancer. Method: Forty-four consecutive patients classified as low- [n = 26, stageT1/T2a, Gleason score ≤ 6, prostate-specific antigen (PSA) 10 (group 2)] risk, who subsequently were monitored with active surveillance or started neoadjuvant hormone and radiotherapy, respectively, underwent endorectal MRI. T2-weighted (T2W) and DW images (5 b values, 0-800 s/mm 2 ) were acquired and isotropic ADC maps generated. Regions of interest (ROIs) on T2W axial images [around whole prostate, central gland (CG), and tumour] were transferred to ADC maps. Tumour, CG, and peripheral zone (PZ = whole prostate minus CG and tumour) ADCs (fast component from b = 0-100 s/mm 2 , slow component from b = 100-800 s/mm 2 ) were compared. Results: T2W-defined tumour volume medians, and quartiles were 1.2 cm 3 , 0.7 and 3.3 cm 3 (group 1); and 6 cm 3 , 1.3 and 16.5 cm 3 (group 2). There were significant differences in both ADC fast (1778 ± 264 x 10 -6 versus 1583 ± 283 x 10 -6 mm 2 /s, p = 0.03) and ADC slow (1379 ± 321 x 10 -6 versus 1196 ± 158 x 10 -6 mm 2 /s, p = 0.001) between groups. Tumour volume (p = 0.002) and ADC slow (p = 0.005) were significant differentiators of risk group. Conclusion: Significant differences in tumour ADCs exist between patients with low-risk, and those with higher-risk localized prostate cancer. DW-MRI merits further study with respect to clinical outcomes

  4. Noninvasive imaging of intracellular lipid metabolism in macrophages by Raman microscopy in combination with stable isotopic labeling.

    Science.gov (United States)

    Matthäus, Christian; Krafft, Christoph; Dietzek, Benjamin; Brehm, Bernhard R; Lorkowski, Stefan; Popp, Jürgen

    2012-10-16

    Monocyte-derived macrophages play a key role in atherogenesis because their transformation into foam cells is responsible for deposition of lipids in plaques within arterial walls. The appearance of cytosolic lipid droplets is a hallmark of macrophage foam cell formation, and the molecular basics involved in this process are not well understood. Of particular interest is the intracellular fate of different individual lipid species, such as fatty acids or cholesterol. Here, we utilize Raman microscopy to image the metabolism of such lipids and to trace their subsequent storage patterns. The combination of microscopic information with Raman spectroscopy provides a powerful molecular imaging method, which allows visualization at the diffraction limit of the employed laser light and biochemical characterization through associated spectral information. In order to distinguish the molecules of interest from other naturally occurring lipids spectroscopically, deuterium labels were introduced. Intracellular distribution and metabolic changes were observed for serum albumin-complexed palmitic and oleic acid and cholesterol and quantitatively evaluated by monitoring the increase in CD scattering intensities at 0.5, 1, 3, 6, 24, 30, and 36 h. This approach may also allow for investigating the cellular trafficking of other molecules, such as nutrients, metabolites, and drugs.

  5. Maximum entropy deconvolution of low count nuclear medicine images

    International Nuclear Information System (INIS)

    McGrath, D.M.

    1998-12-01

    Maximum entropy is applied to the problem of deconvolving nuclear medicine images, with special consideration for very low count data. The physics of the formation of scintigraphic images is described, illustrating the phenomena which degrade planar estimates of the tracer distribution. Various techniques which are used to restore these images are reviewed, outlining the relative merits of each. The development and theoretical justification of maximum entropy as an image processing technique is discussed. Maximum entropy is then applied to the problem of planar deconvolution, highlighting the question of the choice of error parameters for low count data. A novel iterative version of the algorithm is suggested which allows the errors to be estimated from the predicted Poisson mean values. This method is shown to produce the exact results predicted by combining Poisson statistics and a Bayesian interpretation of the maximum entropy approach. A facility for total count preservation has also been incorporated, leading to improved quantification. In order to evaluate this iterative maximum entropy technique, two comparable methods, Wiener filtering and a novel Bayesian maximum likelihood expectation maximisation technique, were implemented. The comparison of results obtained indicated that this maximum entropy approach may produce equivalent or better measures of image quality than the compared methods, depending upon the accuracy of the system model used. The novel Bayesian maximum likelihood expectation maximisation technique was shown to be preferable over many existing maximum a posteriori methods due to its simplicity of implementation. A single parameter is required to define the Bayesian prior, which suppresses noise in the solution and may reduce the processing time substantially. Finally, maximum entropy deconvolution was applied as a pre-processing step in single photon emission computed tomography reconstruction of low count data. Higher contrast results were

  6. Phosphorus nuclear magnetic resonance imaging in solid bone

    International Nuclear Information System (INIS)

    Li, Limin.

    1990-01-01

    Phosphorus ( 31 P) nuclear magnetic resonance (NMR) double-pulse transient experiments of solid bone have shown that the spins dephased by the dipolar spin-spin interactions can be refocused with a 90 degree-β pulse sequence so that an echo is observable at some time following the second pulse. The decay time constant of the maximum echo amplitude is larger than that of the free induction decay (FID) signal from a single 90 degree pulse. Depending on the nutation angle of the second pulse, the former decay time constant is about three-five times as long as the latter one. The dipolar-echo properties of the bone may be relevant with the interpair dipolar interactions. The experiments have also show that, in general, the time for the transient signal from the double pulses to reach the maximum amplitude is not equal to the pulse separation. This can be attributed to the effect of the heteronuclear dipolar interactions. In addition, it is found experimentally that refocused gradients applied only in a time interval of the formation of an echo have the capability of phase-encoding spatial information. Based on this, a new imaging method was proposed. With the method, several 31 P images of the solid bone samples have been obtained. The picture element size is 1-1.5 mm with very good signal-to-noise ratios. The imaging ability of the refocused gradients may be relevant with the inhomogeneous local field produced by the interpair dipolar interactions

  7. Noninvasive Assessment of Gastric Emptying by Near-Infrared Fluorescence Reflectance Imaging in Mice: Pharmacological Validation with Tegaserod, Cisapride, and Clonidine

    Directory of Open Access Journals (Sweden)

    Hans-Ulrich Gremlich

    2004-10-01

    Full Text Available Noninvasive near-infrared fluorescence reflectance imaging (FRI is an in vivo technique to assess physiological and molecular processes in the intact organism. Here we describe a method to assess gastric emptying in mice. TentaGel™ beads with covalently bound cyanine dye (Cy5.5 conjugates as fluorescent probe were administered by oral gavage. The amount of intragastric beads/label was derived from the fluorescence signal intensity measured in a region of interest corresponding to the mouse stomach. The FRI signal intensity decreased as a function of time reflecting gastric emptying. In control mice, the gastric half-emptying time was in agreement with literature data. Pharmacological modulation of gastric motility allowed the evaluation of the sensitivity of the FRI-based method. Gastric emptying was either stimulated or inhibited by treatment with the 5-HT4 receptor agonists tegaserod (Zelnorm® and cisapride or the α2-receptor agonist clonidine, respectively. Tegaserod and cisapride dose-dependently accelerated gastric emptying. In contrast, clonidine dose-dependently delayed gastric emptying. In conclusion, FRI using fluorescently labeled beads allows the reliable determination of gastric emptying as well as the assessment of pharmacological interventions. The technique thus offers the potential to characterize molecular targets and pathways involved in physiological regulation and pharmacological modulation of gastric emptying.

  8. Non-invasive diagnosis in cerebral ischemia by means of magnetic resonance imaging and near-infrared spectroscopy; Nichtinvasive Diagnostik zerebraler Ischaemie mit Kernspintomographie und Nahe-Infrarotspektroskopie

    Energy Technology Data Exchange (ETDEWEB)

    Piepgras, A. [Heidelberg Univ., Mannheim (Germany). Neurochirurgische Klinik; Gueckel, F. [Heidelberg Univ., Mannheim (Germany). Inst. fuer Klinische Radiologie; Laemmler, B. [Heidelberg Univ., Mannheim (Germany). Neurochirurgische Klinik; Weigel, R. [Heidelberg Univ., Mannheim (Germany). Neurochirurgische Klinik; Schmiedek, P. [Heidelberg Univ., Mannheim (Germany). Neurochirurgische Klinik

    1994-11-01

    We describe the non-invasive assessment of cerebrovascular reserve capacity by means of near-infrared spectroscopy (NIRS) and magnetic resonance imaging. Both methods are compared with transcranial Doppler sonography. There is a good correlation of the three methods in the changes in cerebral oxygen saturation and in blood velocity following acetazolamide stimulation of cerebral blood flow, except found in one patient with unilateral carotid artery occlusion. In this patient we found a decreased cerebrovascular reserve capacity, revealed by a magnetic resonance technique designed to quantify CBV and CBF. We postulate a raised oxygen extraction as raised oxygen extraction as the cause of his changes in oxygen saturation. (orig.) [Deutsch] Die Abschaetzung der zerebrovaskulaeren Reservekapazitaet unter Verwendung der Nahe-Infrarotspektroskopie und der Kernspintomographie zur nichtinvasiven klinischen Anwendung wird beschrieben. Beide Verfahren werden mit der transkraniellen Dopplersonographie verglichen. Bei Normalpersonen (n=3) zeigte sich eine gute Uebereinstimmung von Aenderungen der zerebralen Sauerstoffsaettigung mit Aenderungen der Blutflussgeschwindigkeit nach Acetazolamidstimulation der Hirndurchblutung. Diese Uebereinstimmung war bei einem Patienten mit kernspintomographisch nachgewiesener eingeschraenkter zerebrovaskulaerer Reservekapazitaet bei unilateralem Verschluss der A.carotis interna nicht gegeben. Dies wird auf eine pathologisch ehoehte Sauerstoffausschoepfung zurueeckgefuehrt. (orig.)

  9. Non-invasive quantification of hepatic fat fraction by fast 1.0, 1.5 and 3.0 T MR imaging

    International Nuclear Information System (INIS)

    Schuchmann, Sebastian; Weigel, Christiane; Albrecht, Lothar; Kirsch, Michael; Lemke, Arne; Lorenz, Gerd; Warzok, Rolf; Hosten, Norbert

    2007-01-01

    Introduction: Even mild hepatic steatosis in a split liver donor may cause general liver failure and death in the donor. So far, CT density measurements or percutaneous biopsy is used to determine the presence of hepatic steatosis. Magnetic resonance imaging (MRI) may be an elegant method of non-invasive and non-radiation quantification of hepatic fat content. Methods: Fast gradient echo (GRE) technique was used to discriminate between fat and water spins. Echo time (TE) was adjusted for field strength dependent in-phase and out-of-phase states at 1.0, 1.5 and 3.0 T. Continuous MR signal transition from 100% water to 100% fat was investigated using a wedge water-oil phantom, which was positioned in such a way, that no spatial resolution occurred, thereby combining water and fat in one slice. Results: Using the phantom, a significant difference for a 5% difference in fat content was demonstrated in the range from 20 to 80% fat content (p 2 = 0.93 for TE 6 ms and r 2 = 0.91 for TE 10 ms). Conclusion: The described method can be used to determine the presence of hepatic steatosis of >10% with p < 0.05

  10. Non-invasive in vivo evaluation of in situ forming PLGA implants by benchtop magnetic resonance imaging (BT-MRI) and EPR spectroscopy.

    Science.gov (United States)

    Kempe, Sabine; Metz, Hendrik; Pereira, Priscila G C; Mäder, Karsten

    2010-01-01

    In the present study, we used benchtop magnetic resonance imaging (BT-MRI) for non-invasive and continuous in vivo studies of in situ forming poly(lactide-co-glycolide) (PLGA) implants without the use of contrast agents. Polyethylene glycol (PEG) 400 was used as an alternative solvent to the clinically used NMP. In addition to BT-MRI, we applied electron paramagnetic resonance (EPR) spectroscopy to characterize implant formation and drug delivery processes in vitro and in vivo. We were able to follow key processes of implant formation by EPR and MRI. Because EPR spectra are sensitive to polarity and mobility, we were able to follow the kinetics of the solvent/non-solvent exchange and the PLGA precipitation. Due to the high water affinity of PEG 400, we observed a transient accumulation of water in the implant neighbourhood. Furthermore, we detected the encapsulation by BT-MRI of the implant as a response of the biological system to the polymer, followed by degradation over a period of two months. We could show that MRI in general has the potential to get new insights in the in vivo fate of in situ forming implants. The study also clearly shows that BT-MRI is a new viable and much less expensive alternative for superconducting MRI machines to monitor drug delivery processes in vivo in small mammals. Copyright 2009 Elsevier B.V. All rights reserved.

  11. Geospatial Image Mining For Nuclear Proliferation Detection: Challenges and New Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Vatsavai, Raju [ORNL; Bhaduri, Budhendra L [ORNL; Cheriyadat, Anil M [ORNL; Arrowood, Lloyd [Y-12 National Security Complex; Bright, Eddie A [ORNL; Gleason, Shaun Scott [ORNL; Diegert, Carl [Sandia National Laboratories (SNL); Katsaggelos, Aggelos K [ORNL; Pappas, Thrasos N [ORNL; Porter, Reid [Los Alamos National Laboratory (LANL); Bollinger, Jim [Savannah River National Laboratory (SRNL); Chen, Barry [Lawrence Livermore National Laboratory (LLNL); Hohimer, Ryan [Pacific Northwest National Laboratory (PNNL)

    2010-01-01

    With increasing understanding and availability of nuclear technologies, and increasing persuasion of nuclear technologies by several new countries, it is increasingly becoming important to monitor the nuclear proliferation activities. There is a great need for developing technologies to automatically or semi-automatically detect nuclear proliferation activities using remote sensing. Images acquired from earth observation satellites is an important source of information in detecting proliferation activities. High-resolution remote sensing images are highly useful in verifying the correctness, as well as completeness of any nuclear program. DOE national laboratories are interested in detecting nuclear proliferation by developing advanced geospatial image mining algorithms. In this paper we describe the current understanding of geospatial image mining techniques and enumerate key gaps and identify future research needs in the context of nuclear proliferation.

  12. Molecular Testing of Nodules with a Suspicious or Malignant Cytologic Diagnosis in the Setting of Non-Invasive Follicular Thyroid Neoplasm with Papillary-Like Nuclear Features (NIFTP).

    Science.gov (United States)

    Strickland, Kyle C; Eszlinger, Markus; Paschke, Ralf; Angell, Trevor E; Alexander, Erik K; Marqusee, Ellen; Nehs, Matthew A; Jo, Vickie Y; Lowe, Alarice; Vivero, Marina; Hollowell, Monica; Qian, Xiaohua; Wieczorek, Tad; French, Christopher A; Teot, Lisa A; Cibas, Edmund S; Lindeman, Neal I; Krane, Jeffrey F; Barletta, Justine A

    2018-03-01

    Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) is an indolent thyroid tumor characterized by frequent RAS mutations and an absence of the BRAF V600E mutation commonly seen in classical papillary thyroid carcinoma (cPTC). The ability to differentiate potential NIFTP/follicular variant of papillary thyroid carcinoma (FVPTC) from cPTC at the time of fine-needle aspiration (FNA) can facilitate conservative management of NIFTP. The aim of the current study was to investigate how molecular testing may add to cytologic assessment in the pre-operative differentiation of potential NIFTP/FVPTC and cPTC. We had previously evaluated cytologists' ability to prospectively distinguish potential NIFTP/FVPTC from cPTC in a cohort of 56 consecutive FNAs diagnosed as malignant or suspicious for malignancy. We utilized this cohort to perform molecular analysis. Detected molecular abnormalities were stratified into two groups: (1) those supporting malignancy and (2) those supporting a diagnosis of potential NIFTP/FVPTC. The cytologists' characterization of cases and the detected molecular alterations were correlated with the final histologic diagnoses. Molecular testing was performed in 52 (93%) of the 56 cases. For the 37 cases cytologists favored to be cPTC, 31 (84%) had a molecular result that supported malignancy (28 BRAF V600E mutations, 2 NTRK1 fusions, 1 AGK-BRAF fusion). For the 8 cases that were favored to be NIFTP/FVPTC by cytologists, 7 (88%) had a molecular result that supported conservative management (1 NRAS mutation, 6 wild-type result). Seven cases were designated as cytomorphologically indeterminate for NIFTP/FVPTC or cPTC, of which 6 (86%) had a molecular result that would have aided in the pre-operative assessment of potential NIFTP/FVPTC or cPTC/malignancy. These included 3 BRAF V600E mutations in nodules that were cPTC on resection, an HRAS mutation, and a wild-type result in the 2 nodules that were NIFTP, and a TERT promoter

  13. Biomechanics of subcellular structures by non-invasive Brillouin microscopy

    Science.gov (United States)

    Antonacci, Giuseppe; Braakman, Sietse

    2016-11-01

    Cellular biomechanics play a pivotal role in the pathophysiology of several diseases. Unfortunately, current methods to measure biomechanical properties are invasive and mostly limited to the surface of a cell. As a result, the mechanical behaviour of subcellular structures and organelles remains poorly characterised. Here, we show three-dimensional biomechanical images of single cells obtained with non-invasive, non-destructive Brillouin microscopy with an unprecedented spatial resolution. Our results quantify the longitudinal elastic modulus of subcellular structures. In particular, we found the nucleoli to be stiffer than both the nuclear envelope (p biomechanics and its role in pathophysiology.

  14. Imaginary Savior: the image of the nuclear bomb in Korea, 1945-1960.

    Science.gov (United States)

    Kim, Dong-Won

    2009-01-01

    Two atomic bombs dropped on Hiroshima and Nagasaki in August 1945 brought the unexpected liberation of Korea from the 35-year Japanese occupation. Koreans therefore had a very favorable and positive image of the nuclear bomb and nuclear energy from the beginning. The image of the nuclear bomb as "savior" was strengthened during the Korean War when the United States openly mentioned the possible use of the nuclear bomb against North Korean and Chinese military. After the end of the Korean War in July 1953 South Koreans strongly supported the development of the nuclear bomb in order to deter another North Korean invasion. When the US government provided South Korea with a research nuclear reactor in the late 1950s, most South Koreans hailed it as the first step to developing their own nuclear bomb. This paper will analyze how and why the savior image of the nuclear bomb originated and spread in Korea during the 1950s.

  15. Monitoring therapeutic response of human ovarian cancer to 17-DMAG by noninvasive PET imaging with {sup 64}Cu-DOTA-trastuzumab

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Gang; Cao, Qizhen; Chen, Xiaoyuan [Stanford University School of Medicine, The Molecular Imaging Program at Stanford (MIPS), Department of Radiology and Bio-X Program, Stanford, CA (United States); Li, Zibo [Stanford University School of Medicine, The Molecular Imaging Program at Stanford (MIPS), Department of Radiology and Bio-X Program, Stanford, CA (United States); Keck School of Medicine, USC Molecular Imaging Center, Department of Radiology, Los Angeles, CA (United States)

    2009-09-15

    17-Dimethylaminoethylamino-17-demethoxygeldanamycin (17-DMAG), a heat-shock protein 90 (Hsp90) inhibitor, has been intensively investigated for cancer therapy and is undergoing clinical trials. Human epidermal growth factor receptor 2 (HER-2) is one of the client proteins of Hsp90 and its expression is decreased upon 17-DMAG treatment. In this study, we aimed to noninvasively monitor the HER-2 response to 17-DMAG treatment in xenografted mice. The sensitivity of human ovarian cancer SKOV-3 cells to 17-DMAG in vitro was measured by MTT assay. HER-2 expression in SKOV-3 cells was determined by flow cytometry. Nude mice bearing SKOV-3 tumors were treated with 17-DMAG and the therapeutic efficacy was evaluated by tumor size measurement. Both treated and control mice were imaged with microPET using {sup 64}Cu-DOTA-trastuzumab and {sup 18}F-FDG. Biodistribution studies and immunofluorescence staining were performed to validate the microPET results. SKOV-3 cells are sensitive to 17-DMAG treatment, in a dose-dependent manner, with an IC{sub 50} value of 24.72 nM after 72 h incubation. The tumor growth curve supported the inhibition effect of 17-DMAG on SKOV-3 tumors. Quantitative microPET imaging showed that {sup 64}Cu-DOTA-trastuzumab had prominent tumor accumulation in untreated SKOV-3 tumors, which was significantly reduced in 17-DMAG-treated tumors. There was no uptake difference detected by FDG PET. Immunofluorescence staining confirmed the significant reduction in tumor HER-2 level upon 17-DMAG treatment. The early response to anti-Hsp90 therapy was successfully monitored by quantitative PET using {sup 64}Cu-DOTA-trastuzumab. This approach may be valuable in monitoring the therapeutic response in HER-2-positive cancer patients under 17-DMAG treatment. (orig.)

  16. An advanced design of non-radioactive image capturing and management system for applications in non-invasive skin disorder diagnosis

    Science.gov (United States)

    Liu, Carol Y. B.; Luk, David C. K.; Zhou, Kany S. Y.; So, Bryan M. K.; Louie, Derek C. H.

    2015-03-01

    Due to the increasing incidences of malignant melanoma, there is a rising demand for assistive technologies for its early diagnosis and improving the survival rate. The commonly used visual screening method is with limited accuracy as the early phase of melanoma shares many clinical features with an atypical nevus, while conventional dermoscopes are not user-friendly in terms of setup time and operations. Therefore, the development of an intelligent and handy system to assist the accurate screening and long-term monitoring of melanocytic skin lesions is crucial for early diagnosis and prevention of melanoma. In this paper, an advanced design of non-invasive and non-radioactive dermoscopy system was reported. Computer-aided simulations were conducted for optimizing the optical design and uniform illumination distribution. Functional prototype and the software system were further developed, which could enable image capturing at 10x amplified and general modes, convenient data transmission, analysis of dermoscopic features (e.g., asymmetry, border irregularity, color, diameter and dermoscopic structure) for assisting the early detection of melanoma, extract patient information (e.g. code, lesion location) and integrate with dermoscopic images, thus further support long term monitoring of diagnostic analysis results. A clinical trial study was further conducted on 185 Chinese children (0-18 years old). The results showed that for all subjects, skin conditions diagnosed based on the developed system accurately confirmed the diagnoses by conventional clinical procedures. Besides, clinical analysis on dermoscopic features and a potential standard approach by the developed system to support identifying specific melanocytic patterns for dermoscopic examination in Chinese children were also reported.

  17. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis

    International Nuclear Information System (INIS)

    Kaniewska, Malwina; Schuetz, Georg M.; Willun, Steffen; Dewey, Marc; Schlattmann, Peter

    2017-01-01

    To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I"2 statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. (orig.)

  18. Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kaniewska, Malwina; Schuetz, Georg M.; Willun, Steffen; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Schlattmann, Peter [Jena University Hospital, Department of Medical Statistics, Informatics and Documentation, Jena (Germany)

    2017-04-15

    To compare the diagnostic accuracy of computed tomography (CT) in the assessment of global and regional left ventricular (LV) function with magnetic resonance imaging (MRI). MEDLINE, EMBASE and ISI Web of Science were systematically reviewed. Evaluation included: ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and left ventricular mass (LVM). Differences between modalities were analysed using limits of agreement (LoA). Publication bias was measured by Egger's regression test. Heterogeneity was evaluated using Cochran's Q test and Higgins I{sup 2} statistic. In the presence of heterogeneity the DerSimonian-Laird method was used for estimation of heterogeneity variance. Fifty-three studies including 1,814 patients were identified. The mean difference between CT and MRI was -0.56 % (LoA, -11.6-10.5 %) for EF, 2.62 ml (-34.1-39.3 ml) for EDV and 1.61 ml (-22.4-25.7 ml) for ESV, 3.21 ml (-21.8-28.3 ml) for SV and 0.13 g (-28.2-28.4 g) for LVM. CT detected wall motion abnormalities on a per-segment basis with 90 % sensitivity and 97 % specificity. CT is accurate for assessing global LV function parameters but the limits of agreement versus MRI are moderately wide, while wall motion deficits are detected with high accuracy. (orig.)

  19. Radiation Exposure by Nuclear Medicine Imaging Procedures: Case Study

    International Nuclear Information System (INIS)

    Kopjar, N.; Marovic, G.; Prlic, I.; Sencar, J.; Zeljezic, D.; Ramic, S.

    2013-01-01

    Using high-resolution gamma spectrometry, we investigated the activity concentrations of thallium radioisotopes in a urine sample collected during a period of 24 h following nuclear medicine cardiac imaging. As part of a thallium stress test the subject of the study received a radiopharmaceutical preparation with 201Tl (activity 111 MBq). In order to assess whether the cardiac imaging procedure resulted in lymphocyte genome damage, we studied the frequency of sister chromatid exchanges (SCE) and lymphocyte cell kinetics in the blood samples collected before and after the cardiac imaging. The highest activity concentration (538960.9 ± 405.9 Bq/L u rine) was estimated for 201Tl, followed by 1770.54 ± 3.57 Bq/L u rine for 202Tl, and 422.035 ± 2.091 Bq/Lurine for 200Tl. The applied radiopharmaceutical contained 99.595 % of 201Tl, 0.078 % of 200Tl and 0.327 % of 202Tl. The estimated effective dose received through a single exposure to the radiopharmaceutical and calculated for a period of two days was mostly affected by 201Tl (0.0453 mSv). Due to its half-life of 12.2 days, the contribution of 202Tl (0.0008 mSv) to the effective dose was also significant. Results of the cytogenetic analysis indicate that a single diagnostic exposure to thallium caused an increase of SCE frequency and decrease of the proliferation rate index (PRI). Both parameters normalized steadily 14 days after the cardiac imaging procedure, which is also in accord with data obtained in previous studies. Our results indicate the presence of impurities in the radiopharmaceutical which should contain only 201Tl. This calls for a stricter process of quality control for radiopharmaceuticals used in nuclear medical diagnostic procedures. In this particular case, we emphasize 'contamination' with 202Tl, whose contribution to the effective dose cannot be ignored if one takes into account that it has the longest half-life of all three thallium radioisotopes detected in the urine sample.(author)

  20. Intelligent and interactive computer image of a nuclear power plant: The ImagIn project

    International Nuclear Information System (INIS)

    Haubensack, D.; Malvache, P.; Valleix, P.

    1998-01-01

    The ImagIn project consists in a method and a set of computer tools apt to bring perceptible and assessable improvements in the operational safety of a nuclear plant. Its aim is to design an information system that would maintain a highly detailed computerized representation of a nuclear plant in its initial state and throughout its in-service life. It is not a tool to drive or help driving the nuclear plant, but a tool that manages concurrent operations that modify the plant configuration in a very general was (maintenance for example). The configuration of the plant, as well as rules and constraints about it, are described in a object-oriented knowledge database, which is built using a generic ImagIn meta-model based on the semantical network theory. An inference engine works on this database and is connected to reality through interfaces to operators and captors on the installation; it verifies constantly in real-time the consistency of the database according to its inner rules, and reports eventual problems to concerned operators. A special effort is made on interfaces to provide natural and intuitive tools (using virtual reality, natural language, voice recognition and synthesis). A laboratory application on a fictive but realistic installation already exists and is used to simulate various tests and scenarii. A real application is being constructed on Siloe, an experimental reactor of the CEA. (author)

  1. What's new in cardiac imaging?

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Niemeyer, M.G.

    1992-01-01

    Since the introduction of myocardial perfusion imaging and radionuclide angiography in mid-seventies, cardiovascular nuclear medicine has undergone an explosive growth. Use of nuclear cardiology techniques has become one of the cornerstones of noninvasive assessment of coronary artery disease. In the past 15 years, major steps were made from visual analysis to quantitative analysis, from planar imaging to tomographic imaging, from disease-detection to prognosis, and from separate evaluations of perfusion, metabolism and function to an integrated assessment of myocardial viability.In recent years, many more advances have been made in cardiovascular nuclear imaging, such as the development of new imaging agents, re-evaluation of existing procedures, and new clinical applications. This book describes most recent developments in nuclear cardiology and also addresses new contrast agents in MRI. This book will assist clinical cardiologist, cardiology fellow, nuclear medicine physician, and radiologist in understanding the most recent achievements in clinical cardiovascular nuclear imaging

  2. Visualization of cerebellopontine angle lesions by nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ochiai, Chikayuki; Takakura, Kintomo; Machida, Tohru; Araki, Tsutomu; Iio, Masahiro; Basugi, Norihiko.

    1983-01-01

    The preliminary results from the clinical use a prototype whole body nuclear magnetic resonance (NMR) machine constructed by Toshiba Inc. are presented. Cranial NMR scans were performed on more than 30 cases with broad spectrum of neurologic diseases using saturation-recovery and inversion-recovery sequences with a field strength of 1500 Gauss. Selective excitation sequence was used for the slice selection and filtered backprojection was used to reconstruct the images. They were displayed on a 256 x 256 matrix as 12 mm thick sections. Data aquisition time varied between 3 and 12 minutes. Our initial experiences with six cases harboring cerebellopontine angle lesions discolsed advantages and disadvantages of NMR imaging in comparison with X-ray CT. The advantages were the absence of linear artifacts from the surrounding bone, the marked gray-white matter differentiation, and the variety of tomographic planes available. The disadvantages included the lack of bone detail, the lack of visualization of the major intracranial vessels, and the long time required for scanning (several minutes per slice). Although much continued evaluation is necessary, NMR seems to have vast potential as a diagnostic tool. (author)

  3. Nuclear molecular imaging of paragangliomas; Imagerie moleculaire nucleaire des paragangliomes

    Energy Technology Data Exchange (ETDEWEB)

    Taieb, D.; Tessonnier, L.; Mundler, O. [Service central de biophysique et de medecine nucleaire, CHU de la Timone, 13 - Marseille (France)

    2010-08-15

    Paragangliomas (PGL) are relatively rare neural crest tumors originating in the adrenal medulla (usually called pheochromocytoma), chemoreceptors (i.e., carotid and aortic bodies) or autonomic ganglia. These tumors are highly vascular, usually benign and slow-growing. PGL may occur as sporadic or familial entities, the latter mostly in association with germline mutations of the succinate dehydrogenase (SDH) B, SDHC, SDHD, SDH5, von Hippel-Lindau (VHL), ret proto-oncogene (RET), neurofibromatosis 1 (NF1) (von Recklinghausen's disease), prolyl hydroxylase domain protein 2 (PHD2) genes and TMEM127. Molecular nuclear imaging has a central role in characterization of PGL and include: somatostatin receptor imaging ({sup 111}In, {sup 68}Ga), MIBG scintigraphy ({sup 131}I, {sup 123}I), {sup 18}F-dihydroxy-phenylalanine ({sup 18}F-DOPA) positron emission tomography (PET), and {sup 18}F-deoxyglucose ({sup 18}F-FDG) PET. The choice of the tracer is not yet fully established but the work-up of familial forms often require the combination of multiple approaches. (authors)

  4. Magnetic resonance imaging and nuclear magnetic resonance investigations of bentonite systems

    Energy Technology Data Exchange (ETDEWEB)

    Dvinskikh, Sergey V.; Furo, Istvan (Industrial NMR Centre and Div. of Physical Chemistry, Dept. of Chemistry, Royal Institute of Technology, Stockholm (Sweden))

    2009-09-15

    This report summarizes results from a set of magnetic resonance imaging (MRI) and nuclear magnetic resonance (NMR) experiments performed on Ca and Na montmorillonite samples interacting with water. The primary goal with these studies was to provide, in a non-invasive manner, a quantitative measure of bentonite distribution in extended samples during and after different physical processes such as swelling and sedimentation and on the time scale from minutes to years. Additionally, we also studied the distribution of foreign particles (such as native minerals as well as magnetic model particles) within bentonite systems and performed some diffusion NMR experiments with the aim of characterizing the state of colloids that form after clay dissolution. Both natural montmorillonites and purified and ion-exchanged montmorillonite clays were investigated. The primary variables were clay composition and water ionic strength. Bulk samples confined in a vertical tube and in a horizontal channel were investigated. A critical issue for the stability of clay buffer layer in deep underground repository is to prevent or minimize the release of clay particles into the water phase. In our experiments, the most significant particle losses were found for Na-MX80 clay exposed to water with low ionic strength. With increasing the concentration of CaCl{sub 2} in the water phase both swelling and particle release are slowed down but not completely eliminated due probably to gradual change of water ion content via ion exchange with the clay itself. For natural MX80 samples, in spite of significant swelling expansion, no clay particle release above the sensitivity limit of 0.001 volume% was observed. Ca-MX80 exhibited the smallest expansion and no trace of clay particle released into the aqueous phase

  5. Magnetic resonance imaging and nuclear magnetic resonance investigations of bentonite systems

    International Nuclear Information System (INIS)

    Dvinskikh, Sergey V.; Furo, Istvan

    2009-09-01

    This report summarizes results from a set of magnetic resonance imaging (MRI) and nuclear magnetic resonance (NMR) experiments performed on Ca and Na montmorillonite samples interacting with water. The primary goal with these studies was to provide, in a non-invasive manner, a quantitative measure of bentonite distribution in extended samples during and after different physical processes such as swelling and sedimentation and on the time scale from minutes to years. Additionally, we also studied the distribution of foreign particles (such as native minerals as well as magnetic model particles) within bentonite systems and performed some diffusion NMR experiments with the aim of characterizing the state of colloids that form after clay dissolution. Both natural montmorillonites and purified and ion-exchanged montmorillonite clays were investigated. The primary variables were clay composition and water ionic strength. Bulk samples confined in a vertical tube and in a horizontal channel were investigated. A critical issue for the stability of clay buffer layer in deep underground repository is to prevent or minimize the release of clay particles into the water phase. In our experiments, the most significant particle losses were found for Na-MX80 clay exposed to water with low ionic strength. With increasing the concentration of CaCl 2 in the water phase both swelling and particle release are slowed down but not completely eliminated due probably to gradual change of water ion content via ion exchange with the clay itself. For natural MX80 samples, in spite of significant swelling expansion, no clay particle release above the sensitivity limit of 0.001 volume% was observed. Ca-MX80 exhibited the smallest expansion and no trace of clay particle released into the aqueous phase

  6. Nuclear imaging of amyloid deposits based upon thioflavins

    International Nuclear Information System (INIS)

    Wang Yanming; Wu Chunying; Wei Jinjun

    2005-01-01

    Alzheimer's Disease (AD) is a chronic neurodegenerative disorders characterized by the presence of amyloid deposits and neurofibrillar tangles in the brain. Direct assessment of local changes of amyloid deposits in vivo would greatly facilitate the diagnosis and therapeutic treatments of AD. The goal of this study is to develop small-molecule probes that can be used to follow amyloid deposition in vivo in patients with neurodegenerative diseases. Over the past years, we set out to develop a series of small molecules based on thioflavins as radiotracers for use in nuclear imaging modalities such as positron emission tomography and single photon emission computed tomography. The potential of these amyloid-imaging agents for in vivo studies of amyloid deposition has been evaluated based on the following methods: 1) spectrophotometric binding. assays with synthetic amyloid-β (Aβ) fibrils and AD brain homogenates; 2) fluorescent staining of brain tissue sections to evaluate specificity of binding to amyloid deposits; 3) fluorescent microscopy in mouse models to determine the brain permeability and characterize the binding specificity in vivo, and 4) PET studies in human subjects diagnosed with AD and age-matched control subjects. To date, we have identified some lead compounds as molecular probes with specificity towards amyloid deposits. The in vitro and in vivo binding properties of these compounds have been demonstrated in the following ways: 1) they selectively binds to Aβ fibrils; 2) they selectively stains amyloid deposits in AD brain tissue sections; 3) they readily penetrates the blood-brain barrier, selectively detects amyloid deposits in vivo iri living mice; and 4) One of these compounds, termed PIB, has been successfully used in PET studies in human subjects. In conclusion, amyloid-imaging probes have been developed that could be used to monitor amyloid load in vivo. Applications of the probes are under investigation for potential pathophysiology studies

  7. Use of Non-Invasive Phase Contrast Magnetic Resonance Imaging for Estimation of Atrial Septal Defect Size and Morphology: A Comparison with Transesophageal Echo

    International Nuclear Information System (INIS)

    Piaw, Chin Sze; Kiam, Ong Tiong; Rapaee, Annuar; Khoon, Liew Chee; Bang, Liew Houng; Ling, Chan Wei; Samion, Hasri; Hian, Sim Kui

    2006-01-01

    Background: Transesophageal echocardiography (TEE) is a trusted method of sizing atrial septal defect (ASD) prior to percutaneous closure but is invasive, uncomfortable, and may carry a small risk of morbidity and mortality. Magnetic resonance imaging (MRI) may be useful non-invasive alternative in such patients who refuse or are unable to tolerate TEE and may provide additional information on the shape of the A0SD. Purpose: To validate the accuracy of ASD sizing by MRI compared with TEE.Method: Twelve patients (mean age 30 years; range 11-60 years) scheduled for ASD closure underwent TEE, cine balanced fast field echo MRI (bFFE-MRI) in four-chamber and sagittal views and phase-contrast MRI (PC-MRI) with reconstruction using the two orthogonal planes of T2-weighted images as planning. The average of the three longest measurements for all imaging modalities was calculated for each patient. Results: Mean maximum ASD length on TEE was 18.8 ± 4.6 mm, mean length by bFFE-MRI was 20.0 ± 5.0 mm, and mean length by PC-MRI was 18.3 ± 3.6 mm. The TEE measurement was significantly correlated with the bFFE-MRI and PC-MRI measurements (Pearson r = 0.69, p = 0.02 and r = 0.59, p = 0.04, respectively). The mean difference between TEE and bFFE-MRI measurements was -1.2mm (95% CI: -3.7, 1.3) and between TEE and PC-MRI was 0.5 mm (95% CI: -1.9, 2.9). Bland-Altman analysis also determined general agreement between both MRI methods and TEE. The ASDs were egg-shaped in two cases, circular in 1 patient and oval in the remaining patients. Conclusion: ASD sizing by MRI using bFFE and phase-contrast protocols correlated well with TEE estimations. PC-MRI provided additional information on ASD shapes and proximity to adjacent structures

  8. Quantitative parameters to compare image quality of non-invasive coronary angiography with 16-slice, 64-slice and dual-source computed tomography

    International Nuclear Information System (INIS)

    Burgstahler, Christof; Reimann, Anja; Brodoefel, Harald; Tsiflikas, Ilias; Thomas, Christoph; Heuschmid, Martin; Daferner, Ulrike; Drosch, Tanja; Schroeder, Stephen; Herberts, Tina

    2009-01-01

    Multi-slice computed tomography (MSCT) is a non-invasive modality to visualize coronary arteries with an overall good image quality. Improved spatial and temporal resolution of 64-slice and dual-source computed tomography (DSCT) scanners are supposed to have a positive impact on diagnostic accuracy and image quality. However, quantitative parameters to compare image quality of 16-slice, 64-slice MSCT and DSCT are missing. A total of 256 CT examinations were evaluated (Siemens, Sensation 16: n=90; Siemens Sensation 64: n=91; Siemens Definition: n=75). Mean Hounsfield units (HU) were measured in the cavum of the left ventricle (LV), the ascending aorta (Ao), the left ventricular myocardium (My) and the proximal part of the left main (LM), the left anterior descending artery (LAD), the right coronary artery (RCA) and the circumflex artery (CX). Moreover, the ratio of intraluminal attenuation (HU) to myocardial attenuation was assessed for all coronary arteries. Clinical data [body mass index (BMI), gender, heart rate] were accessible for all patients. Mean attenuation (CA) of the coronary arteries was significantly higher for DSCT in comparison to 64- and 16-slice MSCT within the RCA [347±13 vs. 254±14 (64-MSCT) vs. 233±11 (16-MSCT) HU], LM (362±11/275 ± 12/262±9), LAD (332±17/248±19/219±14) and LCX (310±12/210±13/221±10, all p<0.05), whereas there was no significant difference between DSCT and 64-MSCT for the LV, the Ao and My. Heart rate had a significant impact on CA ratio in 16-slice and 64-slice CT only (p<0.05). BMI had no impact on the CA ratio in DSCT only (p<0.001). Improved spatial and temporal resolution of dual-source CT is associated with better opacification of the coronary arteries and a better contrast with the myocardium, which is independent of heart rate. In comparison to MSCT, opacification of the coronary arteries at DSCT is not affected by BMI. The main advantage of DSCT lies with the heart rate independency, which might have a

  9. Noninvasive Test Detects Cardiovascular Disease

    Science.gov (United States)

    2007-01-01

    At NASA's Jet Propulsion Laboratory (JPL), NASA-developed Video Imaging Communication and Retrieval (VICAR) software laid the groundwork for analyzing images of all kinds. A project seeking to use imaging technology for health care diagnosis began when the imaging team considered using the VICAR software to analyze X-ray images of soft tissue. With marginal success using X-rays, the team applied the same methodology to ultrasound imagery, which was already digitally formatted. The new approach proved successful for assessing amounts of plaque build-up and arterial wall thickness, direct predictors of heart disease, and the result was a noninvasive diagnostic system with the ability to accurately predict heart health. Medical Technologies International Inc. (MTI) further developed and then submitted the technology to a vigorous review process at the FDA, which cleared the software for public use. The software, patented under the name Prowin, is being used in MTI's patented ArterioVision, a carotid intima-media thickness (CIMT) test that uses ultrasound image-capturing and analysis software to noninvasively identify the risk for the major cause of heart attack and strokes: atherosclerosis. ArterioVision provides a direct measurement of atherosclerosis by safely and painlessly measuring the thickness of the first two layers of the carotid artery wall using an ultrasound procedure and advanced image-analysis software. The technology is now in use in all 50 states and in many countries throughout the world.

  10. Recent research findings on non-invasive diagnosis of liver fibrosis

    Directory of Open Access Journals (Sweden)

    WU Qiong

    2015-02-01

    Full Text Available Early diagnosis of liver fibrosis and dynamic monitoring of relevant changes have great implications for the treatment and prognosis improvement of chronic liver diseases. So far, liver biopsy remains the “golden standard” for the diagnosis and staging of liver fibrosis. However, due to its inherent limitations, a great effort has been made to develop more accurate non-invasive diagnostic methods, including serum fibrosis markers and mathematical models, ultrasound, contrast-enhanced ultrasonography, ultrasonic elastography, computed tomography, magnetic resonance imaging, and nuclear medicine. The advantages and disadvantages of relevant methods are discussed. Furthermore, proper selection of the non-invasive diagnostic methods for clinical application and the means for mutual verification are analyzed. As for the future direction, it is expected to employ the above methods for combined analysis and comprehensive assessment, in order to enhance the clinical value of non-invasive liver fibrosis diagnosis.

  11. Non-invasive bioluminescence imaging to monitor the immunological control of a plasmablastic lymphoma-like B cell neoplasia after hematopoietic cell transplantation.

    Directory of Open Access Journals (Sweden)

    Martin Chopra

    Full Text Available To promote cancer research and to develop innovative therapies, refined pre-clinical mouse tumor models that mimic the actual disease in humans are of dire need. A number of neoplasms along the B cell lineage are commonly initiated by a translocation recombining c-myc with the immunoglobulin heavy-chain gene locus. The translocation is modeled in the C.129S1-Igha(tm1(MycJanz/J mouse which has been previously engineered to express c-myc under the control of the endogenous IgH promoter. This transgenic mouse exhibits B cell hyperplasia and develops diverse B cell tumors. We have isolated tumor cells from the spleen of a C.129S1-Igha(tm1(MycJanz/J mouse that spontaneously developed a plasmablastic lymphoma-like disease. These cells were cultured, transduced to express eGFP and firefly luciferase, and gave rise to a highly aggressive, transplantable B cell lymphoma cell line, termed IM380. This model bears several advantages over other models as it is genetically induced and mimics the translocation that is detectable in a number of human B cell lymphomas. The growth of the tumor cells, their dissemination, and response to treatment within immunocompetent hosts can be imaged non-invasively in vivo due to their expression of firefly luciferase. IM380 cells are radioresistant in vivo and mice with established tumors can be allogeneically transplanted to analyze graft-versus-tumor effects of transplanted T cells. Allogeneic hematopoietic stem cell transplantation of tumor-bearing mice results in prolonged survival. These traits make the IM380 model very valuable for the study of B cell lymphoma pathophysiology and for the development of innovative cancer therapies.

  12. Dynamic contrast-enhanced magnetic resonance imaging: a non-invasive method to evaluate significant differences between malignant and normal tissue

    International Nuclear Information System (INIS)

    Rudisch, Ansgar; Kremser, Christian; Judmaier, Werner; Zunterer, Hildegard; DeVries, Alexander F.

    2005-01-01

    Purpose: An ever recurring challenge in diagnostic radiology is the differentiation between non-malignant and malignant tissue. Based on evidence that microcirculation of normal, non-malignant tissue differs from that of malignant tissue, the goal of this study was to assess the reliability of dynamic contrast-enhanced Magnetic Resonance Imaging (dcMRI) for differentiating these two entities. Materials and methods: DcMRI data of rectum carcinoma and gluteus maximus muscles were acquired in 41 patients. Using an fast T1-mapping sequence on a 1.5-T whole body scanner, T1-maps were dynamically retrieved before, during and after constant rate i.v. infusion of a contrast medium (CM). On the basis of the acquired data sets, PI-values were calculated on a pixel-by-pixel basis. The relevance of spatial heterogeneities of microcirculation was investigated by relative frequency histograms of the PI-values. Results: A statistically significant difference between malignant and normal tissue was found for the mean PI-value (P < 0.001; 8.95 ml/min/100 g ± 2.45 versus 3.56 ml/min/100 g ± 1.20). Additionally relative frequency distributions of PI-values with equal class intervals of 2.5 ml/min/100 g revealed significant differences between the histograms of muscles and rectum carcinoma. Conclusion: We could show that microcirculation differences between malignant and normal, non-malignant tissue can be reliably assessed by non-invasive dcMRI. Therefore, dcMRI holds great promise in the aid of cancer assessment, especially in patients where biopsy is contraindicated

  13. Non-invasive quantification of hepatic fat fraction by fast 1.0, 1.5 and 3.0 T MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schuchmann, Sebastian [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany)]. E-mail: sebastian.schuchmann@charite.de; Weigel, Christiane [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Albrecht, Lothar [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Kirsch, Michael [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Lemke, Arne [Institut fuer Radiologie, Charite, Universitaetsmedizin Berlin (Germany); Lorenz, Gerd [Institut fuer Pathologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Warzok, Rolf [Institut fuer Pathologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany); Hosten, Norbert [Institut fuer Diagnostische Radiologie and Neuroradiologie, Ernst-Moritz-Arndt Universitaet, Greifswald (Germany)

    2007-06-15

    Introduction: Even mild hepatic steatosis in a split liver donor may cause general liver failure and death in the donor. So far, CT density measurements or percutaneous biopsy is used to determine the presence of hepatic steatosis. Magnetic resonance imaging (MRI) may be an elegant method of non-invasive and non-radiation quantification of hepatic fat content. Methods: Fast gradient echo (GRE) technique was used to discriminate between fat and water spins. Echo time (TE) was adjusted for field strength dependent in-phase and out-of-phase states at 1.0, 1.5 and 3.0 T. Continuous MR signal transition from 100% water to 100% fat was investigated using a wedge water-oil phantom, which was positioned in such a way, that no spatial resolution occurred, thereby combining water and fat in one slice. Results: Using the phantom, a significant difference for a 5% difference in fat content was demonstrated in the range from 20 to 80% fat content (p < 0.05) for all tested field strengths. In 25 patients MRI data were correlated with the percentage of fat determined by histologic evaluation of a CT-guided liver biopsy. Using the linear correlation calculated from the MRI phantom data at 1.0 T, we determined the liver fat from each patient's MRI measurements. Comparison of these data with the histologic quantified fat fraction of liver tissue showed a strong correlation (r {sup 2} = 0.93 for TE 6 ms and r {sup 2} = 0.91 for TE 10 ms). Conclusion: The described method can be used to determine the presence of hepatic steatosis of >10% with p < 0.05.

  14. Non-invasive characterization of polyurethane-based tissue constructs in a rat abdominal repair model using high frequency ultrasound elasticity imaging.

    Science.gov (United States)

    Yu, Jiao; Takanari, Keisuke; Hong, Yi; Lee, Kee-Won; Amoroso, Nicholas J; Wang, Yadong; Wagner, William R; Kim, Kang

    2013-04-01

    The evaluation of candidate materials and designs for soft tissue scaffolds would benefit from the ability to monitor the mechanical remodeling of the implant site without the need for periodic animal sacrifice and explant analysis. Toward this end, the ability of non-invasive ultrasound elasticity imaging (UEI) to assess temporal mechanical property changes in three different types of porous, biodegradable polyurethane scaffolds was evaluated in a rat abdominal wall repair model. The polymers utilized were salt-leached scaffolds of poly(carbonate urethane) urea, poly(ester urethane) urea and poly(ether ester urethane) urea at 85% porosity. A total of 60 scaffolds (20 each type) were implanted in a full thickness muscle wall replacement in the abdomens of 30 rats. The constructs were ultrasonically scanned every 2 weeks and harvested at weeks 4, 8 and 12 for compression testing or histological analysis. UEI demonstrated different temporal stiffness trends among the different scaffold types, while the stiffness of the surrounding native tissue remained unchanged. The changes in average normalized strains developed in the constructs from UEI compared well with the changes of mean compliance from compression tests and histology. The average normalized strains and the compliance for the same sample exhibited a strong linear relationship. The ability of UEI to identify herniation and to characterize the distribution of local tissue in-growth with high resolution was also investigated. In summary, the reported data indicate that UEI may allow tissue engineers to sequentially evaluate the progress of tissue construct mechanical behavior in vivo and in some cases may reduce the need for interim time point animal sacrifice. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Molecular imaging techniques in magnetic resonance imaging and nuclear imaging; Molekulare Bildgebung in der Magnetresonanztomographie und der Nuklearmedizin

    Energy Technology Data Exchange (ETDEWEB)

    Hoegemann, D.; Basilion, J.P.; Weissleder, R. [Center for Molecular Imaging Research, Massachusetts General Hospital, Charleston, MA (United States)

    2001-02-01

    The identification of genetic and biochemical changes allows a more conclusive characterization and classification of disease. Up to now this information is mostly obtained through in vitro analysis after resection or biopsy by immunohistopathology and molecular biology. There is a definite need for non-invasive detection and repeated monitoring of such changes in experimental research as well as in clinical trials. Therefore, it is necessary to develop radiological imaging techniques that not only visualize morphologic and physiologic alterations, but track genetic and biochemical processes. This short review reports some of the various ongoing research projects that address this problem and provide some very promising approaches. (orig.) [German] Die Bestimmung genetischer und biochemischer Veraenderungen erlaubt in zunehmendem Masse die eindeutige Charakterisierung und Klassifikation von Erkrankungen. Bisher ist hierzu in der Regel eine gezielte immunohistopathologische oder molekularbiologische In-vitro-Analyse nach Resektion oder Entnahme einer Biopsie erforderlich. In der experimentellen Forschung wie auch in der klinischen Anwendung sind bildgebende Verfahren wuenschenswert, die eine nichtinvasive Detektion und ein wiederholt durchfuehrbares Monitoring gewaehrleisten. Aus diesem Grunde ist die Entwicklung radiologischer Untersuchungsmethoden erforderlich, die ueber die morphologischen und physiologischen Veraenderungen hinaus eine Beurteilung der genetischen und biochemischen Vorgaenge ermoeglichen. In diesem kurzen Uebersichtsartikel werden einige der zahlreichen aktuellen Forschungsprojekte zusammengefasst, die sich mit diesem Problem beschaeftigen und inzwischen aussichtsreiche Techniken zur Verfuegung stellen. (orig.)

  16. Java-based remote viewing and processing of nuclear medicine images: toward "the imaging department without walls".

    Science.gov (United States)

    Slomka, P J; Elliott, E; Driedger, A A

    2000-01-01

    In nuclear medicine practice, images often need to be reviewed and reports prepared from locations outside the department, usually in the form of hard copy. Although hard-copy images are simple and portable, they do not offer electronic data search and image manipulation capabilities. On the other hand, picture archiving and communication systems or dedicated workstations cannot be easily deployed at numerous locations. To solve this problem, we propose a Java-based remote viewing station (JaRViS) for the reading and reporting of nuclear medicine images using Internet browser technology. JaRViS interfaces to the clinical patient database of a nuclear medicine workstation. All JaRViS software resides on a nuclear medicine department server. The contents of the clinical database can be searched by a browser interface after providing a password. Compressed images with the Java applet and color lookup tables are downloaded on the client side. This paradigm does not require nuclear medicine software to reside on remote computers, which simplifies support and deployment of such a system. To enable versatile reporting of the images, color tables and thresholds can be interactively manipulated and images can be displayed in a variety of layouts. Image filtering, frame grouping (adding frames), and movie display are available. Tomographic mode displays are supported, including gated SPECT. The time to display 14 lung perfusion images in 128 x 128 matrix together with the Java applet and color lookup tables over a V.90 modem is remote nuclear medicine viewing station using Java and an Internet or intranet browser. Images can be made easily and cost-effectively available to referring physicians and ambulatory clinics within and outside of the hospital, providing a convenient alternative to film media. We also find this system useful in home reporting of emergency procedures such as lung ventilation-perfusion scans or dynamic studies.

  17. Quantitative emission tomography by coded aperture imaging in nuclear medicine

    International Nuclear Information System (INIS)

    Guilhem, J.B.

    1982-06-01

    The coded aperture imaging is applied to nuclear medicine, since ten years. However no satisfactory clinical results have been obtained thus for. The reason is that digital reconstruction methods which have been implemented, in particular the method which use deconvolution filtering are not appropriate for quantification. Indeed these methods which all based on the assumption of shift invariance of the coding procedure, which is contradictory to the geometrical recording conditions giving the best depth resolution, do not take into account gamma rays attenuation by tissues and in most cases give tomograms with artefacts from blurred structures. A method is proposed which has not these limitations and considers the reconstruction problem as the ill-conditioned problem of solving a Fredholm integral equation. The main advantage of this method lies in fact that the transmission kernel of the integral equation is obtained experimentally, and the approximate solution of this equation, close enough to the original 3-D radioactive object, can be obtained in spite of the ill-conditioned nature of the problem, by use of singular values decomposition (S. V. D.) of the kernel [fr

  18. Radiation exposures to technologists from nuclear medicine imaging procedures

    International Nuclear Information System (INIS)

    Sloboda, R.S.; Schmid, M.G.; Willis, C.P.

    1986-05-01

    Radiation exposures incurred by nuclear medicine technologists during diagnostic imaging and gamma camera quality control (QC) were measured on a procedural basis over a three-month period using a portable, low-range, self-reading ion chamber. A total of more than 400 measurements were made for 15 selected procedures. From these, mean procedural exposures and standard deviations were calculated. The results show that daily flood phantom QC, at 0.58 mR, and gated cardiac studies, at 0.45 mR, were the two greatest sources of exposure. Other procedures resulted in exposures varying roughly from 0.10 to 0.20 mR. Difficult patients were responsible for a doubling of technologist exposure for many procedures. Standard deviations were large for all procedures, averaging 65% of the mean values. Comparison of technologist exposure inferred from the procedural measurements with the time coincident collective dose equivalent recorded by the TLD service of the Radiation Protection Bureau indicates that approximately half of the collective technologist exposure arose from patient handling and flood QC

  19. Aptamers as radiopharmaceuticals for nuclear imaging and therapy

    International Nuclear Information System (INIS)

    Gijs, Marlies; Aerts, An; Impens, Nathalie; Baatout, Sarah; Luxen, André

    2016-01-01

    Today, radiopharmaceuticals belong to the standard instrumentation of nuclear medicine, both in the context of diagnosis and therapy. The majority of radiopharmaceuticals consist of targeting biomolecules which are designed to interact with a disease-related molecular target. A plethora of targeting biomolecules of radiopharmaceuticals exists, including antibodies, antibody fragments, proteins, peptides and nucleic acids. Nucleic acids have some significant advantages relative to proteinaceous biomolecules in terms of size, production, modifications, possible targets and immunogenicity. In particular, aptamers (non-coding, synthetic, single-stranded DNA or RNA oligonucleotides) are of interest because they can bind a molecular target with high affinity and specificity. At present, few aptamers have been investigated preclinically for imaging and therapeutic applications. In this review, we describe the use of aptamers as targeting biomolecules of radiopharmaceuticals. We also discuss the chemical modifications which are needed to turn aptamers into valuable (radio-)pharmaceuticals, as well as the different radiolabeling strategies that can be used to radiolabel oligonucleotides and, in particular, aptamers.

  20. Fully three-dimensional image reconstruction in radiology and nuclear medicine. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    The proceedings of the meeting on ''fully three-dimensional image reconstruction in radiology and nuclear medicine'' covers contributions on the following topics: CT imaging, PET imaging, fidelity; iterative and few-view CT, CT-analytical; PET/SPECT Compton analytical; doses - spectral methods; phase contrast; compressed sensing- sparse reconstruction; special issues; motion - cardiac.

  1. Evaluation on the imaging of the bronchial blood flow using nuclear angiocardiography

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Hirayama, Jiro; Kanai, Hisakata; Kobayashi, Toshio; Handa, Kenjiro

    1979-01-01

    Nuclear angiocardiography with sup(99m)TcO 4 - was performed for the purpose of the delineation of the systemic perfusion in various lung diseases, using a scintillation camera with a digital minicomputer system. The images of the bronchial blood flow were obtained in cases with primary lung cancer, pulmonary tuberculosis, lung abscess, bronchiectasis and chronic bronchitis. The fair images of the bronchial blood flow were taken in cases of peripheral type, adenocarcinoma and primary foci of atelectatic type in primary lung cancer. The grade of delineation of the bronchial blood flow and vascularity of bronchial artery in foci of primary lung cancer were correlative to the grade of accumulation of 197 HgCl 2 , respectively. The joint use of nuclear angiocardiography and other imagings such as tumor or perfusion one was useful for evaluation of the pulmonary and systemic circulation, and that made isotope diagnosis of primary lung cancer more reliable too. The image as a isocount map extracted out of the image of 197 HgCl 2 or sup(99m)Tc-MAA, was superimposed to the brightness image of the nuclear angiocardiogram (aortic phase). This image superimposition methods were valuable to improve anatomic orientation of the nuclear angiocardiogram. The delineation of the bronchial blood flow on the subtraction image, which obtained from the two time-different images in aortic phase of the nuclear angiocardiogram, was better than that of the original images. (author)

  2. Lessons from other areas of medical imaging - nuclear medicine

    International Nuclear Information System (INIS)

    McCready, V.R.

    1981-01-01

    Ultrasound and nuclear medicine are similar in that they both have been developed for clinical use in the past decade. Unlike X-ray techniques the success or failure of ultrasound and nuclear medicine depend more upon both the operator and the method of display. Since both ultrasound and nuclear medicine use relatively complicated methods of gathering and displaying information some of the lessons learnt during the development of nuclear medicine can be equally applied to ultrasound techniques. (Auth.)

  3. Recent advances in nuclear cardiology

    DEFF Research Database (Denmark)

    Gutte, H.; Petersen, C. Leth; Kjaer, A.

    2008-01-01

    Nuclear cardiology is an essential part of functional, non-invasive, cardiac imaging. Significant advances have been made in nuclear cardiology since planar (201)thallium ((201)TI) scintigraphy was introduced for the evaluation of left ventricular (LV) perfusion nearly 40 years ago. The use...... of nuclear cardiology has been steadily increasing over the last 20 years with important steps being the introduction of (99m)technetium- ((99m)Tc)-labelled perfusion radiotracers, the change from only planar to now much more single photon emission computed tomography (SPECT) and positron emission tomography...... (PET), electrocardiogram gating of nuclear perfusion imaging, and finally introducing nuclear hybrid imaging using either SPECT or PET together with either computed tomography or magnetic resonance imaging. The indications have extended from nearly only coronary artery diseases to several non...

  4. The development of application technology for image processing in nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Yong Bum; Kim, Woog Ki; Sohn, Surg Won; Kim, Seung Ho; Hwang, Suk Yeoung; Kim, Byung Soo

    1991-01-01

    The object of this project is to develop application technology of image processing in nuclear facilities where image signal are used for reliability and safety enhancement of operation, radiation exposure reduce of operator, and automation of operation processing. We has studied such application technology for image processing in nuclear facilities as non-tactile measurement, remote and automatic inspection, remote control, and enhanced analysis of visual information. On these bases, automation system and real-time image processing system are developed. Nuclear power consists in over 50% share of electic power supply of our country nowdays. So, it is required of technological support for top-notch technology in nuclear industry and its related fields. Especially, it is indispensable for image processing technology to enhance the reliabilty and safety of operation, to automate the process in a place like a nuclear power plant and radioactive envionment. It is important that image processing technology is linked to a nuclear engineering, and enhance the reliability abd safety of nuclear operation, as well as decrease the dose rate. (Author)