WorldWideScience

Sample records for normalized pulse width

  1. Pulse-width discriminators

    International Nuclear Information System (INIS)

    Budyashov, Yu.G.; Grebenyuk, V.M.; Zinov, V.G.

    1978-01-01

    A pulse duration discriminator is described which is intended for processing signals from multilayer scintillators. The basic elements of the scintillator are: an input gate, a current generator, an integrating capacitor, a Schmidt trigger and an anticoincidence circuit. The basic circuit of the discriminator and its time diagrams explaining its operating are given. The discriminator is based on microcircuits. Pulse duration discrimination threshold changes continuously from 20 to 100 ns, while its amplitude threshold changes within 20 to 100 mV. The temperature instability of discrimination thresholds (both in pulse width and in amplitude) is better than 0.1 per cent/deg C

  2. Pulse Width Affects Scalp Sensation of Transcranial Magnetic Stimulation.

    Science.gov (United States)

    Peterchev, Angel V; Luber, Bruce; Westin, Gregory G; Lisanby, Sarah H

    Scalp sensation and pain comprise the most common side effect of transcranial magnetic stimulation (TMS), which can reduce tolerability and complicate experimental blinding. We explored whether changing the width of single TMS pulses affects the quality and tolerability of the resultant somatic sensation. Using a controllable pulse parameter TMS device with a figure-8 coil, single monophasic magnetic pulses inducing electric field with initial phase width of 30, 60, and 120 µs were delivered in 23 healthy volunteers. Resting motor threshold of the right first dorsal interosseus was determined for each pulse width, as reported previously. Subsequently, pulses were delivered over the left dorsolateral prefrontal cortex at each of the three pulse widths at two amplitudes (100% and 120% of the pulse-width-specific motor threshold), with 20 repetitions per condition delivered in random order. After each pulse, subjects rated 0-to-10 visual analog scales for Discomfort, Sharpness, and Strength of the sensation. Briefer TMS pulses with amplitude normalized to the motor threshold were perceived as slightly more uncomfortable than longer pulses (with an average 0.89 point increase on the Discomfort scale for pulse width of 30 µs compared to 120 µs). The sensation of the briefer pulses was felt to be substantially sharper (2.95 points increase for 30 µs compared to 120 µs pulse width), but not stronger than longer pulses. As expected, higher amplitude pulses increased the perceived discomfort and strength, and, to a lesser degree the perceived sharpness. Our findings contradict a previously published hypothesis that briefer TMS pulses are more tolerable. We discovered that the opposite is true, which merits further study as a means of enhancing tolerability in the context of repetitive TMS. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Pulse width modulation inverter with battery charger

    Science.gov (United States)

    Slicker, James M.

    1985-01-01

    An inverter is connected between a source of DC power and a three-phase AC induction motor, and a microprocessor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .theta., where .theta. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands for electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a "flyback" DC-DC converter circuit for recharging the battery.

  4. Pulsed rf excited spectrometer having improved pulse width control

    International Nuclear Information System (INIS)

    1977-01-01

    RF excitation for a spectrometer is obtained by pulse width modulating an RF carrier to produce the desired broadband RF exciting spectrum. The RF excitation includes a train of composite RF pulses, each composite pulse having a primary pulse portion of a first RF phase and a second pulse portion of a second RF phase opposite that of the first. In this manner, the finite rise and fall times of the primary pulse portion are compensated for by the corresponding rise and fall times of the secondary pulse portion. The primary pulse portion is lengthened by an amount equal to the secondary pulse portion so that the secondary pulse portion cancels the added primary pulse portion. In a spectrometer, the compensating second pulse component removes certain undesired side bands of the RF excitation caused by the finite rise and fall times of the applied RF pulses. The compensating second pulse component removes certain undesired side bands associated with each of the resonant lines of the excited resonance spectrum of the sample under analysis, particularly for wide band RF excitation

  5. Global synchronization of parallel processors using clock pulse width modulation

    Science.gov (United States)

    Chen, Dong; Ellavsky, Matthew R.; Franke, Ross L.; Gara, Alan; Gooding, Thomas M.; Haring, Rudolf A.; Jeanson, Mark J.; Kopcsay, Gerard V.; Liebsch, Thomas A.; Littrell, Daniel; Ohmacht, Martin; Reed, Don D.; Schenck, Brandon E.; Swetz, Richard A.

    2013-04-02

    A circuit generates a global clock signal with a pulse width modification to synchronize processors in a parallel computing system. The circuit may include a hardware module and a clock splitter. The hardware module may generate a clock signal and performs a pulse width modification on the clock signal. The pulse width modification changes a pulse width within a clock period in the clock signal. The clock splitter may distribute the pulse width modified clock signal to a plurality of processors in the parallel computing system.

  6. Generation of ozone by Ns-width pulsed power

    International Nuclear Information System (INIS)

    Shimomura, Naoyuki; Wakimoto, Masaya; Shinke, Yosuke; Nagata, Masayoshi; Namihira, Takao; Akiyama, Hidenori

    2002-01-01

    The demand of ozone will be increasing for wholesome and environment-conscious sterilizations. The generation of ozone using the pulsed power discharge will apply electron accelerations around the head of streamer discharge principally. The breakdown in reactor often limits the efficient generation. Therefore, the pulse shape should be controlled for dimension of the reactor. It is clear that a pulse shortening is one of effective approaches. Pulsed power voltage with ns-width applies for ozone generation. The effects, on concentration and efficiency of generation, of pulse shape, repetition rate of pulse, flow rate of oxygen gas, and dimension and configuration of reactor, are discussed. The dimension and configuration of the reactor are optimized for the pulse width

  7. Capacitor charging FET switcher with controller to adjust pulse width

    Science.gov (United States)

    Mihalka, Alex M.

    1986-01-01

    A switching power supply includes an FET full bridge, a controller to drive the FETs, a programmable controller to dynamically control final output current by adjusting pulse width, and a variety of protective systems, including an overcurrent latch for current control. Power MOSFETS are switched at a variable frequency from 20-50 kHz to charge a capacitor load from 0 to 6 kV. A ferrite transformer steps up the DC input. The transformer primary is a full bridge configuration with the FET switches and the secondary is fed into a high voltage full wave rectifier whose output is connected directly to the energy storage capacitor. The peak current is held constant by varying the pulse width using predetermined timing resistors and counting pulses. The pulse width is increased as the capacitor charges to maintain peak current. A digital ripple counter counts pulses, and after the desired number is reached, an up-counter is clocked. The up-counter output is decoded to choose among different resistors used to discharge a timing capacitor, thereby determining the pulse width. A current latch shuts down the supply on overcurrent due to either excessive pulse width causing transformer saturation or a major bridge fault, i.e., FET or transformer failure, or failure of the drive circuitry.

  8. Pulse widths effects on scintillator saturation

    International Nuclear Information System (INIS)

    Kohler, D.A.; Chase, L.F.

    1978-08-01

    A test was performed over an extensive range of irrradiance (approximately five orders of magnitude) to see to what extent organic scintillators responded linearly with x-ray input. At the highest levels of irradiance achievable with the experimental configuration, but only for pulses in the region of 4.0 ns or wider, a degree of nonlinear response was observed for some of the scintillators. The data suggest that at levels below 1 mJ/cm 2 -ns it is safe to asume that for pulses 6.5 ns and shorter there is no significant level of nonlinearity to x rays with spectrum. For the cases of undoped NE111 and NE111 doped with 10 percent benzophenone, experimental conditions were such that it was possible to accumulate data significantly above the 1 mJ/cm 2 -ns level of irradiance. It is with these cases that a nonlinear response was observed. It is assumed that the same nonlinearity would have also been noticed had experimental conditions been such that equivalent levels of irradiance could have been achieved at the time the other samples were studied

  9. DIFFUSE DBD IN ATMOSPHERIC AIR AT DIFFERENT APPLIED PULSE WIDTHS

    Directory of Open Access Journals (Sweden)

    Ekaterina Alexandrovna Shershunova

    2015-02-01

    Full Text Available The paper deals with the realization and the diagnostics of the volume diffuse dielectric barrier discharge in 1-mm air gap when applying high voltage rectangular pulses to the electrodes. The effect of the applied pulse width on the discharge dissipated energy was studied in detail. It was found experimentally, the energy stayed nearly constant with the pulse elongation from 600 ns to 1 ms.

  10. Effect of Pulse Width on Oxygen-fed Ozonizer

    Science.gov (United States)

    Okada, Sho; Wang, Douyan; Namihira, Takao; Katsuki, Sunao; Akiyama, Hidenori

    Though general ozonizers based on silent discharge (barrier discharge) have been used to supply ozone at many industrial situations, there is still some problem, such as improvements of ozone yield. In this work, ozone was generated by pulsed discharge in order to improve the characteristics of ozone generation. It is known that a pulse width gives strong effect to the improvement of energy efficiency in exhaust gas processing. In this paper, the effect of pulse duration on ozone generation by pulsed discharge in oxygen would be reported.

  11. Manipulating the retrieved width of stored light pulses

    International Nuclear Information System (INIS)

    Chen Yongfan; Wang Shihhao; Wang Changyi; Yu, Ite A.

    2005-01-01

    We have systematically studied the method proposed by Patnaik et al. [Phys. Rev. A 69, 035803 (2004)] that manipulates the retrieval of stored light pulses. The measured probe pulse width of the retrieval is inversely proportional to the intensity of the reading field. We also show that the method does not introduce any phase shift or jump into the retrieved pulses. Our study demonstrates that the distortion at the output of the light storage can be corrected by manipulating the retrieval process and the phase information of the stored pulses can remain intact during the process

  12. Pulse-Width-Modulating Driver for Brushless dc Motor

    Science.gov (United States)

    Salomon, Phil M.

    1991-01-01

    High-current pulse-width-modulating driver for brushless dc motor features optical coupling of timing signals from low-current control circuitry to high-current motor-driving circuitry. Provides high electrical isolation of motor-power supply, helping to prevent fast, high-current motor-driving pulses from being coupled through power supplies into control circuitry, where they interfere with low-current control signals.

  13. Utility Interfaced Pulse-Width Modulation of Solar Fed Voltage ...

    African Journals Online (AJOL)

    Utility Interfaced Pulse-Width Modulation of Solar Fed Voltage Source Inverter Using Fixed-Band Hysteresis Current Controller Method. ... with the conversion of solar energy into electrical energy; boosting the dc power; inversion of the dc to ac and then synchronization of the inverter output with the utility, and consequently, ...

  14. Energy detection UWB system based on pulse width modulation

    Directory of Open Access Journals (Sweden)

    Song Cui

    2014-05-01

    Full Text Available A new energy detection ultra-wideband system based on pulse width modulation is proposed. The bit error rate (BER performance of this new system is slightly worst than that of a pulse position modulation (PPM system in additive white Gaussian noise channels. In multipath channels, this system does not suffer from cross-modulation interference as PPM, so it can achieve better BER performance than PPM when cross-modulation interference occurs. In addition, when synchronisation errors occur, this system is more robust than PPM.

  15. Single event effects in pulse width modulation controllers

    International Nuclear Information System (INIS)

    Penzin, S.H.; Crain, W.R.; Crawford, K.B.; Hansel, S.J.; Kirshman, J.F.; Koga, R.

    1996-01-01

    SEE testing was performed on pulse width modulation (PWM) controllers which are commonly used in switching mode power supply systems. The devices are designed using both Set-Reset (SR) flip-flops and Toggle (T) flip-flops which are vulnerable to single event upset (SEU) in a radiation environment. Depending on the implementation of the different devices the effect can be significant in spaceflight hardware

  16. Space Vector Pulse Width Modulation of a Multi-Level Diode ...

    African Journals Online (AJOL)

    Space Vector Pulse Width Modulation of a Multi-Level Diode Clamped ... of MATLAB /SIMULINK modeling of the space vector pulse-width modulation and the ... two adjacent active vectors in determining the switching process of the multilevel ...

  17. A 350 KV nanosecond pulse voltage generator with adjustable pulsed-width

    International Nuclear Information System (INIS)

    Wang, X.; Wang, M.; Chen, Y.Q.; Zeng, L.G.; Han, M.

    2002-01-01

    This paper presents a 350 kV nanosecond pulse voltage generator (NPVG). The voltage pulsed-width can be adjusted from 30 to 160 ns. The generator consists of: Marx generator, pulsed forming line (PFL), main switch and matched impedance. The output voltage of Marx generator is over than nU c (n- the stage number of Marx generator, U c -the charging voltage of capacitor). When the pulse forming line is terminated with an impedance that is over than the characteristic impedance of PFL, the higher voltage pulse was provided for the load

  18. Picoseconds pulse generation and pulse width determination processes of a distributed feedback dye laser

    International Nuclear Information System (INIS)

    Abdul Ghani, B.; Hammadi, M.

    2004-08-01

    A mathematical model has been developed to describe the dynamic emission of Nd-glass, distributed feedback dye laser (DFDL), and periodical grating temperature. The suggested model allows the investigation of the time behavior of Nd-glass laser and DFDL pulsed. Moreover, it allows studying the effect of the laser input parameters of Nd-glass laser on the spectral characteristics of the output DFDL pulses such as pulse width, delay time, and time separation

  19. Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

    International Nuclear Information System (INIS)

    Shin, Young Kil; Choi, Dong Myung

    2007-01-01

    By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well

  20. Pulse-width modulated DC-DC power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2008-01-01

    This book studies switch-mode power supplies (SMPS) in great detail. This type of converter changes an unregulated DC voltage into a high-frequency pulse-width modulated (PWM) voltage controlled by varying the duty cycle, then changes the PWM AC voltage to a regulated DC voltage at a high efficiency by rectification and filtering. Used to supply electronic circuits, this converter saves energy and space in the overall system. With concept-orientated explanations, this book offers state-of-the-art SMPS technology and promotes an understanding of the principle operations of PWM converters,

  1. A Novel Transcranial Magnetic Stimulator Inducing Near Rectangular Pulses with Controllable Pulse Width (cTMS)

    Science.gov (United States)

    Jalinous, Reza; Lisanby, Sarah H.

    2013-01-01

    A novel transcranial magnetic stimulation (TMS) device with controllable pulse width (PW) and near rectangular pulse shape (cTMS) is described. The cTMS device uses an insulated gate bipolar transistor (IGBT) with appropriate snubbers to switch coil currents up to 7 kA, enabling PW control from 5 μs to over 100 μs. The near-rectangular induced electric field pulses use 22–34% less energy and generate 67–72% less coil heating compared to matched conventional cosine pulses. CTMS is used to stimulate rhesus monkey motor cortex in vivo with PWs of 20 to 100 μs, demonstrating the expected decrease of threshold pulse amplitude with increasing PW. The technological solutions used in the cTMS prototype can expand functionality, and reduce power consumption and coil heating in TMS, enhancing its research and therapeutic applications. PMID:18232369

  2. Effect of pulse width on near-infrared supercontinuum generation in nonlinear fiber amplifier

    Science.gov (United States)

    Song, Rui; Lei, Cheng-Min; Chen, Sheng-Ping; Wang, Ze-Feng; Hou, Jing

    2015-08-01

    The effect of pulse width on near-infrared supercontinuum generation in nonlinear fiber amplifier is investigated theoretically and experimentally. The complex Ginzburg-Landau equation and adaptive split-step Fourier method are used to simulate the propagation of pulses with different pulse widths in the fiber amplifier, and the results show that a longer pulse is more profitable in near-infrared supercontinuum generation if the central wavelength of the input laser lies in the normal dispersion region of the gain fiber. A four-stage master oscillator power amplifier configuration is adopted and the output spectra under picosecond and nanosecond input pulses are compared with each other. The experimental results are in good accordance with the simulations which can provide some guidance for further optimization of the system. Project supported by the National Natural Science Foundation of China (Grant Nos. 11404404 and 11274385) and the Outstanding Youth Fund Project of Hunan Province and the Fund of Innovation of National University of Defense Technology, China (Grant No. B120701).

  3. Suppression of high-frequency perturbations in pulse-width modulation

    DEFF Research Database (Denmark)

    2008-01-01

    A method suppresses high-frequency perturbations in a pulse-width modulated signal. The pulse-width modulation may superpose a carrier signal onto an input signal having a predetermined modulation frequency. The carrier signals may be phase-shifted. The resulting modulated signals may...

  4. A New Selective Harmonic Elimination Pulse- Width and Amplitude Modulation (SHEPWAM) for Drive Applications

    DEFF Research Database (Denmark)

    Ghoreishy, Hoda; Varjani, Ali Yazdian; Mohamadian, Mustafa

    2013-01-01

    Compared to the conventional selective harmonic elimination-pulse width modulation (SHE-PWM), the selective harmonic elimination-pulse width and amplitude modulation (SHE-PWAM) control strategy results in significant improvements in the performance of CHB inverters. This fact is due to considerin...

  5. Meterwavelength Single-pulse Polarimetric Emission Survey. IV. The Period Dependence of Component Widths of Pulsars

    Science.gov (United States)

    Skrzypczak, Anna; Basu, Rahul; Mitra, Dipanjan; Melikidze, George I.; Maciesiak, Krzysztof; Koralewska, Olga; Filothodoros, Alexandros

    2018-02-01

    The core component width in normal pulsars, with periods (P) > 0.1 s, measured at the half-power point at 1 GHz, has a lower boundary line (LBL) that closely follows the P ‑0.5 scaling relation. This result is of fundamental importance for understanding the emission process and requires extended studies over a wider frequency range. In this paper we have carried out a detailed study of the profile component widths of 123 normal pulsars observed in the Meterwavelength Single-pulse Polarimetric Emission Survey at 333 and 618 MHz. The components in the pulse profile were separated into core and conal classes. We found that at both frequencies, the core, as well as the conal component widths versus period, had a LBL that followed the P ‑0.5 relation with a similar lower boundary. The radio emission in normal pulsars has been observationally shown to arise from a narrow range of heights around a few hundred kilometers above the stellar surface. In the past the P ‑0.5 relation has been considered as evidence for emission arising from last open dipolar magnetic field lines. We show that the P ‑0.5 dependence only holds if the trailing and leading half-power points of the component are associated with the last open field line. In such a scenario we do not find any physical motivation that can explain the P ‑0.5 dependence for both core and conal components as evidence for dipolar geometry in normal pulsars. We believe the period dependence is a result of a currently unexplained physical phenomenon.

  6. Losses analysis of soft magnetic ring core under sinusoidal pulse width modulation (SPWM) and space vector pulse width modulation (SVPWM) excitations

    Science.gov (United States)

    Gao, Hezhe; Li, Yongjian; Wang, Shanming; Zhu, Jianguo; Yang, Qingxin; Zhang, Changgeng; Li, Jingsong

    2018-05-01

    Practical core losses in electrical machines differ significantly from those experimental results using the standardized measurement method, i.e. Epstein Frame method. In order to obtain a better approximation of the losses in an electrical machine, a simulation method considering sinusoidal pulse width modulation (SPWM) and space vector pulse width modulation (SVPWM) waveforms is proposed. The influence of the pulse width modulation (PWM) parameters on the harmonic components in SPWM and SVPWM is discussed by fast Fourier transform (FFT). Three-level SPWM and SVPWM are analyzed and compared both by simulation and experiment. The core losses of several ring samples magnetized by SPWM, SVPWM and sinusoidal alternating current (AC) are obtained. In addition, the temperature rise of the samples under SPWM, sinusoidal excitation are analyzed and compared.

  7. Influence of pulse width and target density on pulsed laser deposition of thin YBaCuO film

    International Nuclear Information System (INIS)

    Vikram, S.

    1999-01-01

    We have studied the effects of temporal pulse width and target density on the deposition of thin films of YBaCuO. A 248nm excimer laser and an 825nm Ti-sapphire laser were used to conduct the experiments with pulse widths of 27 ns, 16 ns, and 150 fs, and target densities of 80% and 90%. Scanning electron microscope photomicrographs and profilometer traces show a striking difference between nanosecond and femtosecond laser irradiation. Shortening the pulse width reduced particulate formation, provided stoichiometry, and improved the film properties. Decreasing the target density raised the ablation rate, produced thicker but nonuniform films, and reduced particulate formation

  8. Influence of pulse width and target density on pulsed laser deposition of thin YBaCuO film.

    Energy Technology Data Exchange (ETDEWEB)

    Vikram, S.

    1999-01-20

    We have studied the effects of temporal pulse width and target density on the deposition of thin films of YBaCuO. A 248nm excimer laser and an 825nm Ti-sapphire laser were used to conduct the experiments with pulse widths of 27 ns, 16 ns, and 150 fs, and target densities of 80% and 90%. Scanning electron microscope photomicrographs and profilometer traces show a striking difference between nanosecond and femtosecond laser irradiation. Shortening the pulse width reduced particulate formation, provided stoichiometry, and improved the film properties. Decreasing the target density raised the ablation rate, produced thicker but nonuniform films, and reduced particulate formation.

  9. space vector pulse width modulation of a multi-level diode clamped

    African Journals Online (AJOL)

    ES Obe

    step by step development of MATLAB /SIMULINK modeling of the space vector ..... Pulse Width Mod. of Multi-Level Diode Clamped Converter 119 powergui. Discrete, .... Load. Figure 22: Block diagram of the three level DCC design. 3 LEVEL ...

  10. Clinically insubstantial cognitive side effects of bitemporal electroconvulsive therapy at 0.5 msec pulse width.

    Science.gov (United States)

    Warnell, Ronald L; Swartz, Conrad M; Thomson, Alice

    2011-11-01

    We measured cognitive side effects from bitemporal electroconvulsive therapy (ECT) using stimuli of 0.5 msec pulse width 900 milliamperes (mA). Mini-Mental State Exam (MMSE) and 21-item Hamilton Rating Scale for Depression (HRSD-21) were rated within 36 hours before and 36 hours after a series of 6 bitemporal ECT sessions on 15 patients age ≥45. MMSE remained high after ECT (pre-ECT mean 29, standard deviation [SD] 1.60, post-ECT mean 28.53, SD 1.36) with no significant change. The mean HRSD-21 fell from 27.5 to 16.3. Post-ECT MMSE was significantly and markedly higher than in previous studies of bitemporal ECT; all had used ECT stimuli of pulse width at least 1 msec. With stimuli of 0.5 msec pulse width and 900 mA, 6 bitemporal ECTs did not decrease MMSE score. This result leaves no opportunity for further decrease in basic cognitive side effects, and complements published reports of stronger physiological effects with stimuli of 0.5 msec pulse width and 900 mA. ECT stimuli of 0.5 msec pulse width and 900 mA are more desirable than wider pulse widths. Six bitemporal ECT sessions using these stimuli generally will not have more cognitive side effects than treatments with other placements, allowing maintenance of full efficacy with clinically insubstantial side effects.

  11. Optimal time-domain technique for pulse width modulation in power electronics

    Directory of Open Access Journals (Sweden)

    I. Mayergoyz

    2018-05-01

    Full Text Available Optimal time-domain technique for pulse width modulation is presented. It is based on exact and explicit analytical solutions for inverter circuits, obtained for any sequence of input voltage rectangular pulses. Two optimal criteria are discussed and illustrated by numerical examples.

  12. Stark widths of Xe II lines in a pulsed plasma

    International Nuclear Information System (INIS)

    Djurovic, S; Pelaez, R J; Cirisan, M; Aparicio, J A; Mar, S

    2006-01-01

    In this paper, we present a review of experimental work on Stark broadening of singly ionized xenon lines. Eighty lines, from close UV to the red region of the spectrum, have been studied. Stark halfwidths were compared with experimental data from the literature and modified semi-empirical calculations. A pulsed arc with 95% of helium and 5% xenon was used as a plasma source for this study. Measured electron densities N e and temperatures T were in the ranges of 0.2-1.6 x 10 23 m -3 and 18 300-25 500 K, respectively

  13. Effects of microwave pulse-width damage on a bipolar transistor

    International Nuclear Information System (INIS)

    Ma Zhen-Yang; Chai Chang-Chun; Ren Xing-Rong; Yang Yin-Tang; Chen Bin; Zhao Ying-Bo

    2012-01-01

    This paper presents a theoretical study of the pulse-width effects on the damage process of a typical bipolar transistor caused by high power microwaves (HPMs) through the injection approach. The dependences of the microwave damage power, P, and the absorbed energy, E, required to cause the device failure on the pulse width τ are obtained in the nanosecond region by utilizing the curve fitting method. A comparison of the microwave pulse damage data and the existing dc pulse damage data for the same transistor is carried out. By means of a two-dimensional simulator, ISE-TCAD, the internal damage processes of the device caused by microwave voltage signals and dc pulse voltage signals are analyzed comparatively. The simulation results suggest that the temperature-rising positions of the device induced by the microwaves in the negative and positive half periods are different, while only one hot spot exists under the injection of dc pulses. The results demonstrate that the microwave damage power threshold and the absorbed energy must exceed the dc pulse power threshold and the absorbed energy, respectively. The dc pulse damage data may be useful as a lower bound for microwave pulse damage data. (interdisciplinary physics and related areas of science and technology)

  14. Tissue effects of Ho:YAG laser with varying fluences and pulse widths

    Science.gov (United States)

    Vari, Sandor G.; van der Veen, Maurits J.; Pergadia, Vani R.; Shi, Wei-Qiang; Duffy, J. T.; Weiss, Andrew B.; Fishbein, Michael C.; Grundfest, Warren S.

    1994-02-01

    We investigated the effect of varying fluence and pulse width on the ablation rate and consequent thermal damage of the Ho:YAG (2.130 micrometers ) laser. The rate of ablation on fresh bovine knee joint tissues, fibrous cartilage, hyaline cartilage, and bone in saline was determined after varying the fluence (160 - 640 J/cm2) and pulse width (150, 250, 450 microsecond(s) ec, FWHM) at a repetition rate of 2 Hz. A 400/440 micrometers fiber was used. The ablation rate increased linearly with the fluence. In fibrocartilage, different pulse durations generated significant changes in the ablation rates, but showed minor effects on hyaline cartilage and bone. The heat of ablation for all three tissue types decreased after lengthening the pulse.

  15. Design of a variable width pulse generator feasible for manual or automatic control

    Energy Technology Data Exchange (ETDEWEB)

    Vegas, I., E-mail: ignacio.vegas@pas.ucm.es; Antoranz, P.; Miranda, J.M.; Franco, F.J.

    2017-01-01

    A variable width pulse generator featuring more than 4-V peak amplitude and less than 10-ns FWHM is described. In this design the width of the pulses is controlled by means of the control signal slope. Thus, a variable transition time control circuit (TTCC) is also developed, based on the charge and discharge of a capacitor by means of two tunable current sources. Additionally, it is possible to activate/deactivate the pulses when required, therefore allowing the creation of any desired pulse pattern. Furthermore, the implementation presented here can be electronically controlled. In conclusion, due to its versatility, compactness and low cost it can be used in a wide variety of applications.

  16. Double-Carrier Phase-Disposition Pulse Width Modulation Method for Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Zhou, Fayun; Luo, An; Li, Yan

    2017-01-01

    Modular multilevel converters (MMCs) have become one of the most attractive topologies for high-voltage and high-power applications. A double-carrier phase disposition pulse width modulation (DCPDPWM) method for MMCs is proposed in this paper. Only double triangular carriers with displacement ang......, the proposed method and theoretical analysis are verified by simulation and experimental results. View Full-Text...

  17. Equalization of Skin Effect Loss Dominated Channels using Pulse-Width Modulation (PWM) Pre-Emphasis

    NARCIS (Netherlands)

    Schrader, J.H.R.; Klumperink, Eric A.M.; Visschers, J.L.; Nauta, Bram

    2005-01-01

    A digital transmitter pre-emphasis technique is presented that is based on pulse-width modulation, instead of finite impulse response (FIR) filtering. The technique fits well to future high-speed low-voltage CMOS processes. A 0.13μm CMOS transmitter achieves more than 5Gb/s (2-PAM) over 25m of

  18. A New Technique for SET Pulse Width Measurement in Chains of Inverters Using Pulsed Laser Irradiation

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Fel, N.; Gaillardin, M.; Baggio, J.; Girard, S.; Flament, O.; Paillet, P.; McMorrow, D.; Melinger, J. S.; Kobayashi, D.; Hirose, K.; Saito, H.; Pouget, V.; Essely, F.; Schwank, J. R.; Flores, R. S.; Dodd, P. E.; Shaneyfelt, M. R.

    2009-01-01

    A new technique is developed to measure precisely and accurately the width of propagating voltage transients induced by irradiation of inverter chains. The technique is based on measurement of the supply current in a detection inverter, and permits a direct determination of the transient width with a 50 GHz bandwidth. (authors)

  19. Effects of finite pulse width on two-dimensional Fourier transform electron spin resonance.

    Science.gov (United States)

    Liang, Zhichun; Crepeau, Richard H; Freed, Jack H

    2005-12-01

    Two-dimensional (2D) Fourier transform ESR techniques, such as 2D-ELDOR, have considerably improved the resolution of ESR in studies of molecular dynamics in complex fluids such as liquid crystals and membrane vesicles and in spin labeled polymers and peptides. A well-developed theory based on the stochastic Liouville equation (SLE) has been successfully employed to analyze these experiments. However, one fundamental assumption has been utilized to simplify the complex analysis, viz. the pulses have been treated as ideal non-selective ones, which therefore provide uniform irradiation of the whole spectrum. In actual experiments, the pulses are of finite width causing deviations from the theoretical predictions, a problem that is exacerbated by experiments performed at higher frequencies. In the present paper we provide a method to deal with the full SLE including the explicit role of the molecular dynamics, the spin Hamiltonian and the radiation field during the pulse. The computations are rendered more manageable by utilizing the Trotter formula, which is adapted to handle this SLE in what we call a "Split Super-Operator" method. Examples are given for different motional regimes, which show how 2D-ELDOR spectra are affected by the finite pulse widths. The theory shows good agreement with 2D-ELDOR experiments performed as a function of pulse width.

  20. Effects of Pulse Width and Electrode Placement on the Efficacy and Cognitive Effects of Electroconvulsive Therapy

    Science.gov (United States)

    Sackeim, Harold A.; Prudic, Joan; Nobler, Mitchell S.; Fitzsimons, Linda; Lisanby, Sarah H.; Payne, Nancy; Berman, Robert M.; Brakemeier, Eva-Lotta; Perera, Tarique; Devanand, D. P.

    2009-01-01

    BACKGROUND While electroconvulsive therapy (ECT) in major depression is effective, cognitive effects limit its use. Reducing the width of the electrical pulse and using the right unilateral electrode placement may decrease adverse cognitive effects, while preserving efficacy. METHODS In a double-masked study, we randomly assigned 90 depressed patients to right unilateral ECT at 6 times seizure threshold or bilateral ECT at 2.5 times seizure threshold, using either a traditional brief pulse (1.5 ms) or an ultrabrief pulse (0.3 ms). Depressive symptoms and cognition were assessed before, during, and immediately, two, and six months after therapy. Patients who responded were followed for a one-year period. RESULTS The final remission rate for ultrabrief bilateral ECT was 35 percent, compared with 73 percent for ultrabrief unilateral ECT, 65 percent for standard pulse width bilateral ECT, and 59 percent for standard pulse width unilateral ECT (all P’stherapy. Both the ultrabrief stimulus and right unilateral electrode placement produced less short- and long-term retrograde amnesia. Patients rated their memory deficits as less severe following ultrabrief right unilateral ECT compared to each of the other three conditions (P<0.001). CONCLUSIONS The use of an ultrabrief stimulus markedly reduces adverse cognitive effects, and when coupled with markedly suprathreshold right unilateral ECT, also preserves efficacy. (ClinicalTrials.gov number, NCT00487500.) PMID:19756236

  1. Nanosecond pulse-width electron diode based on dielectric wall accelerator technology

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Quantang, E-mail: zhaoquantang@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhang, Z.M.; Yuan, P.; Cao, S.C.; Shen, X.K.; Jing, Y. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Yu, C.S. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Li, Z.P.; Liu, M.; Xiao, R.Q. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Zong, Y.; Wang, Y.R. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhao, H.W. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2013-11-21

    An electron diode using a short section of dielectric wall accelerator (DWA) has been under development at the Institute of Modern Physics (IMP), Chinese Academy of Sciences. Tests have been carried out with spark gap switches triggered by lasers. The stack voltage efficiency of a four-layer of Blumleins reached about 60–70% with gas filled spark gap switching. The generated pulse voltage of peak amplitude of 23 kV and pulse width of 5 ns is used to extract and accelerate an electron beam of 320 mA, measured by a fast current transformer. A nanosecond pulse width electron diode was achieved successfully. Furthermore, the principle of a DWA is well proven and the development details and discussions are presented in this article. -- Highlights: •The key technology of DWA, including switches and pulse forming lines were studied. •The SiC PCSS obtained from Shanghai Institute were tested. •Two layers ZIP lines (new structure) and four layers Blumlein lines were studied with laser triggered spark gap switches. •A nanosecond pulse-width electron diode based on DWA technologies is achieved and studied experimentally. •The principle of DWA is also proved by the diode.

  2. Using the ultra-long pulse width pulsed dye laser and elliptical spot to treat resistant nasal telangiectasia.

    Science.gov (United States)

    Madan, Vishal; Ferguson, Janice

    2010-01-01

    Thick linear telangiectasia on the ala nasi and nasolabial crease can be resistant to treatment with the potassium-titanyl-phosphate (KTP) laser and the traditional round spot on a pulsed dye laser (PDL). We evaluated the efficacy of a 3 mm x 10 mm elliptical spot using the ultra-long pulse width on a Candela Vbeam(R) PDL for treatment of PDL- and KTP laser-resistant nasal telangiectasia. Nasal telangiectasia resistant to PDL (12 patients) and KTP laser (12 patients) in 18 patients were treated with a 3 mm x 10 mm elliptical spot on the ultra-long pulse pulsed dye laser (ULPDL) utilising long pulse width [595 nm, 40 ms, double pulse, 30:20 dynamic cooling device (DCD)]. Six patients had previously received treatment with both PDL and KTP laser prior to ULPDL (40 treatments, range1-4, mean 2.2). Complete clearance was seen in ten patients, and eight patients displayed more than 80% improvement after ULPDL treatment. Self-limiting purpura occurred with round spot PDL and erythema with KTP laser and ULPDL. Subtle linear furrows along the treatment sites were seen in three patients treated with the KTP laser. ULPDL treatment delivered using a 3 mm x 10 mm elliptical spot was non-purpuric and highly effective in the treatment of nasal telangiectasia resistant to KTP laser and PDL.

  3. A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging

    Science.gov (United States)

    Coyle, Barry; Poulios, Demetrios

    2013-01-01

    A fiber/solid-state hybrid seeded regenerative amplifier, capable of achieving high output energy with tunable pulse widths, has been developed for satellite laser ranging applications. The regenerative amplifier cavity uses a pair of Nd:YAG zigzag slabs oriented orthogonally to one another in order to make thermal lensing effects symmetrical and simplify optical correction schemes. The seed laser used is a fiber-coupled 1,064-nm narrowband (pumped by a single 120-W, pulsed 808-nm laser diode array. In this configuration, the average pump beam distribution in the slabs had a 1-D Gaussian shape, which matches the estimated cavity mode size. A half-wave plate between the slabs reduces losses from Fresnel reflections due to the orthogonal slabs Brewster-cut end faces. Successful "temporal" seeding of the regenerative amplifier cavity results in a cavity Q-switch pulse envelope segmenting into shorter pulses, each having the width of the input seed, and having a uniform temporal separation corresponding to the cavity round-trip time of approx. =10 ns. The pulse energy is allowed to build on successive passes in the regenerative amplifier cavity until a maximum is reached, (when cavity gains and losses are equal), after which the pulse is electro- optically switched out on the next round trip The overall gain of the amplifier is approx. =82 dB (or a factor of 1.26 million). After directing the amplified output through a LBO frequency doubling crystal, approx. = 2.1 W of 532-nm output (>1 mJ) was measured. This corresponds to a nonlinear conversion efficiency of >60%. Furthermore, by pulse pumping this system, a single pulse per laser shot can be created for the SLR (satellite laser ranging) measurement, and this can be ejected into the instrument. This is operated at the precise frequency needed by the measurement, as opposed to commercial short-pulsed, mode-locked systems that need to operate in a continuous fashion, or CW (continuous wave), and create pulses at many

  4. Adaptive pulse amplitude pulse width control of systems subject to Coulomb and viscous friction

    NARCIS (Netherlands)

    Wijdeven, van de J.J.M.; Singh, T.

    2003-01-01

    The focus of this paper is on adaptive controlof maneuvering rigid bodies in the presence offriction. The paper describes a simple techniquewhich include Pulse Amplitude and Pulse Widthmodulation to progressively move the system tothe desired final position. To account for uncertaintyin estimated

  5. Bit rate and pulse width dependence of four-wave mixing of short optical pulses in semiconductor optical amplifiers

    DEFF Research Database (Denmark)

    Diez, S.; Mecozzi, A.; Mørk, Jesper

    1999-01-01

    We investigate the saturation properties of four-wave mixing of short optical pulses in a semiconductor optical amplifier. By varying the gain of the optical amplifier, we find a strong dependence of both conversion efficiency and signal-to-background ratio on pulse width and bit rate....... In particular, the signal-to-background ratio can be optimized for a specific amplifier gain. This behavior, which is coherently described in experiment and theory, is attributed to the dynamics of the amplified spontaneous emission, which is the main source of noise in a semiconductor optical amplifier....

  6. Solution of the pulse width modulation problem using orthogonal polynomials and Korteweg-de Vries equations.

    Science.gov (United States)

    Chudnovsky, D V; Chudnovsky, G V

    1999-10-26

    The mathematical underpinning of the pulse width modulation (PWM) technique lies in the attempt to represent "accurately" harmonic waveforms using only square forms of a fixed height. The accuracy can be measured using many norms, but the quality of the approximation of the analog signal (a harmonic form) by a digital one (simple pulses of a fixed high voltage level) requires the elimination of high order harmonics in the error term. The most important practical problem is in "accurate" reproduction of sine-wave using the same number of pulses as the number of high harmonics eliminated. We describe in this paper a complete solution of the PWM problem using Pade approximations, orthogonal polynomials, and solitons. The main result of the paper is the characterization of discrete pulses answering the general PWM problem in terms of the manifold of all rational solutions to Korteweg-de Vries equations.

  7. Measured pulse width of sonoluminescence flashes in the form of resonance radiation

    Science.gov (United States)

    Giri, Asis; Arakeri, Vijay H.

    1998-09-01

    Recent studies have shown that the measured flash widths from single and multibubble sonoluminescence are in subnanosecond or even picosecond regime. Here, we provide conclusive evidence for the existence of nanosecond multibubble sonoluminescence. This has become possible by our ability to find a medium from which exclusive sodium D line resonance radiation as a form of sonoluminescence is possible. The measured flash width of this emission is found to be in the range of tens of nanoseconds and is sensitively dependent on experimental parameters. Our finding is important since all the earlier pulse width measurements have been limited to emission with the physical source or species responsible for observed optical radiation not being clearly identified. We propose that the presently observed resonance radiation is from ``soft'' bubble collapse as analyzed by V. Kamath et al. [J. Acoust. Soc. Am. 94, 248 (1993)].

  8. Effect of Pulse Width on Ozone Generation in Pulsed Streamer Discharges

    OpenAIRE

    Tamaribuchi, Hiroyuki; Wang, Douyan; Namihira, Takao; Katsuki, Sunao; Akiyama, Hidenori; タマリブチ, ヒロユキ; オウ, トエン; ナミヒラ, タカオ; カツキ, スナオ; アキヤマ, ヒデノリ; 溜渕, 浩之; 王, 斗艶; 浪平, 隆男; 勝木, 淳; 秋山, 秀典

    2007-01-01

    Ozone has been used in treatment of drinking water andwaste water (e.g., deodorization, decolorization, anddisinfection). Though general ozonizers based on silentdischarge or barrier discharge have been used to supplyozone at many industrial situations, there is still someproblem, such as improvements of ozone concentrationand ozone yield.In this work, ozone was generated by pulsed powerdischarge in order to improve the characteristics of ozonegeneration. High electric field with short pulse ...

  9. Femtosecond pulse-width dependent trapping and directional ejection dynamics of dielectric nanoparticles

    KAUST Repository

    Chiang, Weiyi

    2013-09-19

    We demonstrate that laser pulse duration, which determines its impulsive peak power, is an effective parameter to control the number of optically trapped dielectric nanoparticles, their ejections along the directions perpendicular to polarization vector, and their migration distances from the trapping site. This ability to controllably confine and eject the nanoparticle is explained by pulse width-dependent optical forces exerted on nanoparticles in the trapping site and ratio between the repulsive and attractive forces. We also show that the directional ejections occur only when the number of nanoparticles confined in the trapping site exceeds a definite threshold. We interpret our data by considering the formation of transient assembly of the optically confined nanoparticles, partial ejection of the assembly, and subsequent filling of the trapping site. The understanding of optical trapping and directional ejections by ultrashort laser pulses paves the way to optically controlled manipulation and sorting of nanoparticles. © 2013 American Chemical Society.

  10. Study on the E-beam pulse width scaling for a 25-kilojoule KrF amplifier

    International Nuclear Information System (INIS)

    Ramirez, J.J.

    1983-02-01

    The KrF laser is being considered as an ICF driver candidate. Since this laser is not an energy storing system, the output energy of an amplifier is delivered over the entire pulse width of the excitation source. E-beam pumping is preferred for large energy systems. The e-beam pulse width is constrained to a few hundred nanoseconds by laser operation and pulsed power considerations. The target requires pulses of a few nanoseconds. Angular multiplexing of probe beams through the amplifier is a preferred scheme for bridging this difference in timing requirements. Progressively shorter target irradiation times may be obtained by using shorter pulse probe beams and by either increasing the number of angular multiplexed beams or by decreasing the e-beam pulse width. This report documents results of a study on the consequences of following the latter approach

  11. New hybrid reverse differential pulse position width modulation scheme for wireless optical communication

    Science.gov (United States)

    Liao, Renbo; Liu, Hongzhan; Qiao, Yaojun

    2014-05-01

    In order to improve the power efficiency and reduce the packet error rate of reverse differential pulse position modulation (RDPPM) for wireless optical communication (WOC), a hybrid reverse differential pulse position width modulation (RDPPWM) scheme is proposed, based on RDPPM and reverse pulse width modulation. Subsequently, the symbol structure of RDPPWM is briefly analyzed, and its performance is compared with that of other modulation schemes in terms of average transmitted power, bandwidth requirement, and packet error rate over ideal additive white Gaussian noise (AWGN) channels. Based on the given model, the simulation results show that the proposed modulation scheme has the advantages of improving the power efficiency and reducing the bandwidth requirement. Moreover, in terms of error probability performance, RDPPWM can achieve a much lower packet error rate than that of RDPPM. For example, at the same received signal power of -28 dBm, the packet error rate of RDPPWM can decrease to 2.6×10-12, while that of RDPPM is 2.2×10. Furthermore, RDPPWM does not need symbol synchronization at the receiving end. These considerations make RDPPWM a favorable candidate to select as the modulation scheme in the WOC systems.

  12. Laser ion source with long pulse width for RHIC-EBIS

    International Nuclear Information System (INIS)

    Kondo, K.; Kanesue, T.; Okamura, M.

    2011-01-01

    The Electron Beam Ion Source (EBIS) at Brookhaven National Laboratory is a new heavy ion-projector for RHIC and NASA Space Radiation Laboratory. Laser Ion Source (LIS) with solenoid can supply many kinds of ion from solid targets and is suitable for long pulse length with low current as ion provider for RHIC-EBIS. In order to understand a plasma behavior for fringe field of solenoid, we measure current, pulse width and total ion charges by a new ion probe. The experimental result indicates that the solenoid confines the laser ablation plasma transversely. Laser ion source needs long pulse length with limited current as primary ion provider for RHIC-EBIS. New ion probe can measure current distribution for the radial positions along z axis. The beam pulse length is not effected by magnetic field strength. However, the currents and charges decay with the distance from the end of solenoid. These results indicate that solenoid field has important role for plasma confinement not longitudinally but transversely and solenoid is able to have long pulse length with sufficient total ion charges. Moreover, the results are useful for a design of the extraction system for RHIC-EBIS.

  13. CEDM Controller for a Linear Pulse Motor by using Pulse Width Modulation Method in Integral Reactor

    International Nuclear Information System (INIS)

    Lee, Joon-Koo; Keum, Jong-Yong; Park, Heui-Youn

    2007-01-01

    Integral Reactor SMART is under development at KAERI. The design characteristics of SMART are radically different from those employed in currently operating loop type PWR in Korea. The reliability and accuracy of Control Rod Drive Mechanism are very important to the reactor safety and the design of the Plant Protection System. The SMART CEDM designed for fine-step movement consists of a linear pulse motor, reed switch type sensor with top and bottom limit switches which also act as Control Element Assembly(CEA) Position indicator, The linear pulse motor is a four phase synchronous DC electric machine with inner stator and output stator in coolant medium inside a strong housing. The objective of this paper is to introduce and to explain the CEDM controller CEDM Controller is being developed with a new design concept and digital technology to reduce the Operating Error and improve the systems' reliability and availability. And Switched Mode Power Supply is also being developed with digital hardware technology. This paper involves the test details and result

  14. New autocorrelation technique for the IR FEL optical pulse width measurements

    Energy Technology Data Exchange (ETDEWEB)

    Amirmadhi, F.; Brau, K.A.; Becker, C. [Vanderbilt Univ., Nashville, TN (United States)] [and others

    1995-12-31

    We have developed a new technique for the autocorrelation measurement of optical pulse width at the Vanderbilt University FEL center. This method is based on nonlinear absorption and transmission characteristics of semiconductors such as Ge, Te and InAs suitable for the wavelength range from 2 to over 6 microns. This approach, aside being simple and low cost, removes the phase matching condition that is generally required for the standard frequency doubling technique and covers a greater wavelength range per nonlinear material. In this paper we will describe the apparatus, explain the principal mechanism involved and compare data which have been acquired with both frequency doubling and two-photon absorption.

  15. Laboratory manual for pulse-width modulated DC-DC power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2015-01-01

    Designed to complement a range of power electronics study resources, this unique lab manual helps students to gain a deep understanding of the operation, modeling, analysis, design, and performance of pulse-width modulated (PWM) DC-DC power converters.  Exercises focus on three essential areas of power electronics: open-loop power stages; small-signal modeling, design of feedback loops and PWM DC-DC converter control schemes; and semiconductor devices such as silicon, silicon carbide and gallium nitride. Meeting the standards required by industrial employers, the lab manual combines program

  16. Enhancement of mosquito trapping efficiency by using pulse width modulated light emitting diodes

    OpenAIRE

    Liu, Yu-Nan; Liu, Yu-Jen; Chen, Yi-Chian; Ma, Hsin-Yi; Lee, Hsiao-Yi

    2017-01-01

    In this study, a light-driving bug zapper is presented for well controlling the diseases brought by insects, such as mosquitoes. In order to have the device efficient to trap the insect pests in off-grid areas, pulse width modulated light emitting diodes (PWM-LED) combined with a solar power module are proposed and implemented. With specific PWM electric signals to drive the LED, it is found that no matter what the ability of catching insects or the consumed power efficiency can be enhanced t...

  17. A novel approach for pulse width measurements with a high precision (8 ps RMS) TDC in an FPGA

    International Nuclear Information System (INIS)

    Ugur, C.; Linev, S.; Schweitzer, T.; Traxler, M.; Michel, J.

    2016-01-01

    High precision time measurements are a crucial element in particle identification experiments, which likewise require pulse width information for Time-over-Threshold (ToT) measurements and charge measurements (correlated with pulse width). In almost all of the FPGA-based TDC applications, pulse width measurements are implemented using two of the TDC channels for leading and trailing edge time measurements individually. This method however, requires twice the number of resources. In this paper we present the latest precision improvements in the high precision TDC (8 ps RMS) developed before [1], as well as the novel way of measuring ToT using a single TDC channel, while still achieving high precision (as low as 11.7 ps RMS). The effect of voltage, generated by a DC-DC converter, over the precision is also discussed. Finally, the outcome of the temperature change over the pulse width measurement is shown and a correction method is suggested to limit the degradation

  18. Isolated PDM and PWM DC-AC SICAMs[Pulse Density Modulated; Pulse Width Modulated

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report a class of isolated PDM and PWM DC-AC SICAMs is described, which introduce the audio reference only in the output stage. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitor. Isolation from the AC mains is achieved using a high frequency (HF) transformer, receiving the HF voltage pulses from the input 'inverter' stage and transferring them to the output 'rectifier+inverter' stage, which can use either PDM or PWM. The latter stage is then interfaced to the load using an output low-pass filter. Each of the dedicated stages is discussed in detail. Measurements on the master/slave PWM DC-AC SICAM prototype are presented to help benchmarking the performance of this class of SICAMs and identify the advantages and drawbacks. (au)

  19. Controllable pulse width of bright similaritons in a tapered graded index diffraction decreasing waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, S. Arun [Department of EEE, Anna University, Ramanathapuram 623513 (India); Malathi, V. [Department of EEE, Anna University, Regional office, Madurai (India); Mani Rajan, M. S., E-mail: senthilmanirajanofc@gmail.com [Department of Physics, Anna University, Ramanathapuram 623513 (India); Loomba, Shally [Department of Physics, Panjab University, Chandigarh 160014 (India)

    2016-03-15

    We obtain the bright similariton solutions for generalized inhomogeneous nonlinear Schrödinger equation (GINLSE) which governs the pulse propagation in a tapered graded index diffraction decreasing waveguide (DDW). The exact solutions have been worked out by employing similarity transformations which involve the mapping of the GINLSE to standard NLSE for the certain conditions of the parameters. By making use of the exact analytical solutions, we have investigated the dynamical behavior of optical similariton pairs and have suggested the methods to control them as they propagate through DDW. Moreover, pulse width of similariton is controlled through various profiles. These results are helpful to understand the similaritons in DDW and can be potentially useful for future experiments in optical communications which involve optical amplifiers and long-haul telecommunication networks.

  20. Pulse width and height modulation for multi-level resistance in bi-layer TaOx based RRAM

    Science.gov (United States)

    Alamgir, Zahiruddin; Beckmann, Karsten; Holt, Joshua; Cady, Nathaniel C.

    2017-08-01

    Mutli-level switching in resistive memory devices enables a wide range of computational paradigms, including neuromorphic and cognitive computing. To this end, we have developed a bi-layer tantalum oxide based resistive random access memory device using Hf as the oxygen exchange layer. Multiple, discrete resistance levels were achieved by modulating the RESET pulse width and height, ranging from 2 kΩ to several MΩ. For a fixed pulse height, OFF state resistance was found to increase gradually with the increase in the pulse width, whereas for a fixed pulse width, the increase in the pulse height resulted in drastic changes in resistance. Resistive switching in these devices transitioned from Schottky emission in the OFF state to tunneling based conduction in the ON state, based on I-V curve fitting and temperature dependent current measurements. These devices also demonstrated endurance of more than 108 cycles with a satisfactory Roff/Ron ratio and retention greater than 104 s.

  1. Single-mode pulsed dye laser pumped by using a diode-pumped Nd:YAG laser with a long pulse width

    International Nuclear Information System (INIS)

    Yi, Jong Hoon; Kim, Jin Tae; Moon, Hee Jong; Rho, Si Pyo; Han, Jae Min; Rhee, Yong Joo; Lee, Jong Min

    1999-01-01

    The lasing characteristics of a single-mode dye laser pumped by using a diode-pumped solid-state laser (DPSSL) with a high repetition rate is described. A 45-mm-long Nd:YAG rod was pumped by three CW diode arrays and it was acousto-optically Q-switched. A KTP crystal was used for intracavity frequency doubling. The pulse width of the laser ranged from 90 ns to 200 ns, depending on the diode current and the Q-switching frequency. The single-mode dye laser had a grazing incidence configuration. The pulse width of the dye laser was reduced to about 1/8 of the pumping laser pulse width. The effects of the DPSSL Q-switching frequency, the driving current, and the cavity loss on the dye laser pulse width were investigated by using a simple plane-parallel cavity. From the measured pulse width of the dye laser as a function of the reflectivity of the dye laser output coupler, we found that the cavity loss due to the frequency selection elements and the output coupler should be less than 70 % in order to avoid a drastically reduced pulse width

  2. Study on two phase flow characteristics in annular pulsed extraction column with different ratio of annular width to column diameter

    International Nuclear Information System (INIS)

    Qin Wei; Dai Youyuan; Wang Jiading

    1994-01-01

    Annular pulsed extraction column can successfully provide large throughput and can be made critically safe for fuel reprocessing. This investigation is to study the two phase flow characteristics in annular pulsed extraction column with four different annular width. 30% TBP (in kerosene)-water is used (water as continuous phase). Results show that modified Pratt correlation is valid under the experimental operation conditions for the annular pulsed extraction column. The characteristic velocity U K decreased with the increase of energy input and increased with the increase of the ratio of annular width to column diameter. Flooding velocity correlation is suggested. The deviation of the calculated values from the experimental data is within +20% for four annular width in a pulsed extraction column

  3. Controlling DC-DC converters by chaos-based pulse width modulation to reduce EMI

    International Nuclear Information System (INIS)

    Li Hong; Zhang Bo; Li Zhong; Halang, Wolfgang A.; Chen Guanrong

    2009-01-01

    In this paper, periodic and chaotic behaviors of DC-DC converters under certain parametric conditions are simulated, experimentally verified, and analyzed. Motivated by the work of J.H.B. Deane and D.C. Hamill in 1996, where chaotic phenomena are useful in suppressing electromagnetic interference (EMI) by adjusting the parameters of the DC-DC converter and making it operate in chaos, a chaos-based pulse width modulation (CPWM) is proposed to distribute the harmonics of the DC-DC converters continuously and evenly over a wide frequency range, thereby reducing the EMI. The output waves and spectral properties of the EMI are simulated and analyzed as the carrier frequency or amplitude changes with regard to different chaotic maps. Simulation and experimental results are given to illustrate the effectiveness of the proposed CPWM, which provides a good example of applying chaos theory in engineering practice.

  4. Effect of different methods of pulse width modulation on power losses in an induction motor

    Science.gov (United States)

    Gulyaev, Alexander; Fokin, Dmitrii; Shuharev, Sergey; Ten, Evgenii

    2017-10-01

    We consider the calculation of modulation power losses in a system “induction motor-inverter” for various pulse width modulation (PWM) methods of the supply voltage. Presented values of modulation power losses are the result of modeling a system “DC link - two-level three-phase voltage inverter - induction motor - load”. In this study the power losses in a system “induction motor - inverter” are computed, as well as losses caused by higher harmonics of PWM supply voltage, followed by definition of active power consumed by the DC link for a specified value mechanical power on the induction motor shaft. Mechanical power was determined by the rotation speed and the torque on the motor shaft in various quasi-sinusoidal supply voltage PWM modes. These calculations reveal the best coefficient of performance (COP) in a system of a variable frequency drive (VFD) with independent voltage inverter controlled by induction motor PWM.

  5. Voltage control on TEG-inverter system with pulse width modulation

    International Nuclear Information System (INIS)

    Kimura, N.; Kinoshita, H.; Matsuura, K.

    1984-01-01

    An ocean thermoelectric generating system can be expected to supply cheap electric power in future. And it can be used as base power supply or isolated power source in developing areas. The authors propose to apply forced-commutation inverter to thermoelectric energy conversion system and construct an electric power station which can be operated without any other synchronous generator (S-G) and can control ac system as stable as S-G. This paper shows that inverters can control voltage constant, though within a range of 10% load change, by using pulse width modulation (PWM). It also describes the design of the voltage control system covering from 50% to 100% load with combination of PWM and output voltage tap changing of TEG

  6. Enhancement of mosquito trapping efficiency by using pulse width modulated light emitting diodes

    Science.gov (United States)

    Liu, Yu-Nan; Liu, Yu-Jen; Chen, Yi-Chian; Ma, Hsin-Yi; Lee, Hsiao-Yi

    2017-01-01

    In this study, a light-driving bug zapper is presented for well controlling the diseases brought by insects, such as mosquitoes. In order to have the device efficient to trap the insect pests in off-grid areas, pulse width modulated light emitting diodes (PWM-LED) combined with a solar power module are proposed and implemented. With specific PWM electric signals to drive the LED, it is found that no matter what the ability of catching insects or the consumed power efficiency can be enhanced thus. It is demonstrated that 40% of the UV LED consumed power and 25.9% of the total load power consumption can be saved, and the trapped mosquitoes are about 250% increased when the PWM method is applied in the bug zapper experiments.

  7. Space Vector Pulse Width Modulation Strategy for Single-Phase Three-Level CIC T-source Inverter

    DEFF Research Database (Denmark)

    Shults, Tatiana E.; Husev, Oleksandr O.; Blaabjerg, Frede

    2016-01-01

    This paper presents a novel space vector pulse-width modulation strategy for a single-phase three-level buck-boost inverter based on an impedance-source network. The case study system is based on T-source inverter with continuous input current. To demonstrate the improved performance of the inver......This paper presents a novel space vector pulse-width modulation strategy for a single-phase three-level buck-boost inverter based on an impedance-source network. The case study system is based on T-source inverter with continuous input current. To demonstrate the improved performance...... of the inverter, the strategy was compared the traditional pulse-width modulation. It is shown that the approach proposed has fewer switching states and does not suffer from neutral point misbalance....

  8. Single-mode pulsed dye laser pumped by using a diode-pumped Nd:YAG laser with a long pulse width

    CERN Document Server

    Yi, J H; Moon, H J; Rho, S P; Han, J M; Rhee, Y J; Lee, J M

    1999-01-01

    The lasing characteristics of a single-mode dye laser pumped by using a diode-pumped solid-state laser (DPSSL) with a high repetition rate is described. A 45-mm-long Nd:YAG rod was pumped by three CW diode arrays and it was acousto-optically Q-switched. A KTP crystal was used for intracavity frequency doubling. The pulse width of the laser ranged from 90 ns to 200 ns, depending on the diode current and the Q-switching frequency. The single-mode dye laser had a grazing incidence configuration. The pulse width of the dye laser was reduced to about 1/8 of the pumping laser pulse width. The effects of the DPSSL Q-switching frequency, the driving current, and the cavity loss on the dye laser pulse width were investigated by using a simple plane-parallel cavity. From the measured pulse width of the dye laser as a function of the reflectivity of the dye laser output coupler, we found that the cavity loss due to the frequency selection elements and the output coupler should be less than 70 % in order to avoid a drast...

  9. Normal width of the anterior commissure of true vocal cord in Korea adults measured by helical CT

    International Nuclear Information System (INIS)

    Lim, Woo Young; Lim, Dong Hoon; Moon, Jang Il; Ko, Yong Seok; Byeon, Joo Nam; Oh, Jae Hee

    1998-01-01

    To evaluate the mean width of anterior commissure of true vocal cord in Korean adults by measuring its dimension on spiral CT scans. We reviewed the CT scans of 53 Korean adults(age range, 23-73years; mean age 39.2 years;M:F=3D41:12) without laryngeal disorders. Soiral CT scanning was performed around the anterior commissure with 1mm slice thickness and table incrementation for 15 seconds. The anteroposterior width of the anterior commissure was measured on CT scan where the true vocal cord and arytenoid, cricoid and thyroid cartilages were all present. We determined the mean width of the anterior commissure and whether there was a relationship between age and the width of the anterior commissure. The width of the anterior commissure was between 0.9mm and 2.3mm;mean width was 1.60±0.38mm(mean±SD). Using two SDs above the mean would have defined 2.36mm as the upper limit of normal width. Statistically, no significant correlation existed between the age and the width of the anterior commissure(p>0.05). An awareuess of the normal width range of the anterior commissure in Korean adults evaluated by spiral CT enhances the possibility of early detection of invasion of the anterior commissure by glottic cancer.=20

  10. Pulse width modulation-based temperature tracking for feedback control of a shape memory alloy actuator.

    Science.gov (United States)

    Ayvali, Elif; Desai, Jaydev P

    2014-04-01

    This work presents a temperature-feedback approach to control the radius of curvature of an arc-shaped shape memory alloy (SMA) wire. The nonlinear properties of the SMA such as phase transformation and its dependence on temperature and stress make SMA actuators difficult to control. Tracking a desired trajectory is more challenging than controlling just the position of the SMA actuator since the desired path is continuously changing. Consequently, tracking the desired strain directly or tracking the parameters such as temperature and electrical resistance that are related to strain with a model is a challenging task. Temperature-feedback is an attractive approach when direct measurement of strain is not practical. Pulse width modulation (PWM) is an effective method for SMA actuation and it can be used along with a compensator to control the temperature of the SMA. Using the constitutive model of the SMA, the desired temperature profile can be obtained for a given strain trajectory. A PWM-based nonlinear PID controller with a feed-forward heat transfer model is proposed to use temperature-feedback for tracking a desired temperature trajectory. The proposed controller is used during the heating phase of the SMA actuator. The controller proves to be effective in tracking step-wise and continuous trajectories.

  11. SWITCH MODE PULSE WIDTH MODULATED DC-DC CONVERTER WITH MULTIPLE POWER TRANSFORMERS

    DEFF Research Database (Denmark)

    2009-01-01

    A switch mode pulse width modulated DC-DC power converter comprises at least one first electronic circuit on a input side (1) and a second electronic circuit on a output side (2). The input side (1) and the output side (2) are coupled via at least two power transformers (T1, T2). Each power...... transformer (T1, T2) comprises a first winding (T1a, T2a) arranged in a input side converter stage (3, 4) on the input side (1) and a second winding (T1 b, T2b) arranged in a output side converter stage (5) on the output side (2), and each of the windings (T1a, T1 b, T2a, T2b) has a first end and a second end....... The first electronic circuit comprises terminals (AO, A1) for connecting a source or a load, at least one energy storage inductor (L) coupled in series with at least one of the first windings (T1a, T2a) of the power transformers (T1, T2), and for each power transformer (T1, T2), an arrangement of switches...

  12. Pulse width modulation based pneumatic frequency tuner of the superconducting resonators at IUAC

    International Nuclear Information System (INIS)

    Pandey, A.; Suman, S.K.; Mathuria, D.S.

    2015-01-01

    The existing phase locking scheme of the quarter wave resonators (QWR) used in superconducting linear accelerator (LINAC) of IUAC consists of a fast time (electronic) and a slow time (pneumatic) control. Presently, piezo based mechanical tuners are being used to phase lock the resonators installed in the second and third accelerating modules of LINAC. However, due to space constraint, the piezo tuner can't be implemented on the resonators of the first accelerating module. Therefore, helium gas operated mechanical tuners are being used to phase lock the resonators against the master oscillator (MO) frequency. The present pneumatic frequency tuner has limitations of non-linearity, hysteresis and slow response time. To overcome these problems and to improve the dynamics of the existing tuner, a new pulse width modulation (PWM) based pneumatic frequency tuning system was adopted and successfully tested. After successful test, the PWM based pneumatic frequency tuner was installed in four QWR of the first accelerating module of LINAC. During beam run the PWM based frequency tuner performed well and the cavities could be phase locked at comparatively higher accelerating fields. A comparison of the existing tuning mechanism and the PWM based tuning system along with the test results will be presented in the paper. (author)

  13. Using Pulse Width Modulation for Wireless Transmission of Neural Signals in Multichannel Neural Recording Systems

    Science.gov (United States)

    Yin, Ming; Ghovanloo, Maysam

    2013-01-01

    We have used a well-known technique in wireless communication, pulse width modulation (PWM) of time division multiplexed (TDM) signals, within the architecture of a novel wireless integrated neural recording (WINeR) system. We have evaluated the performance of the PWM-based architecture and indicated its accuracy and potential sources of error through detailed theoretical analysis, simulations, and measurements on a setup consisting of a 15-channel WINeR prototype as the transmitter and two types of receivers; an Agilent 89600 vector signal analyzer and a custom wideband receiver, with 36 and 75 MHz of maximum bandwidth, respectively. Furthermore, we present simulation results from a realistic MATLAB-Simulink model of the entire WINeR system to observe the system behavior in response to changes in various parameters. We have concluded that the 15-ch WINeR prototype, which is fabricated in a 0.5-μm standard CMOS process and consumes 4.5 mW from ±1.5 V supplies, can acquire and wirelessly transmit up to 320 k-samples/s to a 75-MHz receiver with 8.4 bits of resolution, which is equivalent to a wireless data rate of ~ 2.26 Mb/s. PMID:19497823

  14. Research of narrow pulse width, high repetition rate, high output power fiber lasers for deep space exploration

    Science.gov (United States)

    Tang, Yan-feng; Li, Hong-zuo; Wang, Yan; Hao, Zi-qiang; Xiao, Dong-Ya

    2013-08-01

    As human beings expand the research in unknown areas constantly, the deep space exploration has become a hot research topic all over the world. According to the long distance and large amount of information transmission characteristics of deep space exploration, the space laser communication is the preferred mode because it has the advantages of concentrated energy, good security, and large information capacity and interference immunity. In a variety of laser source, fibre-optical pulse laser has become an important communication source in deep space laser communication system because of its small size, light weight and large power. For fiber lasers, to solve the contradiction between the high repetition rate and the peak value power is an important scientific problem. General Q technology is difficult to obtain a shorter pulse widths, This paper presents a DFB semiconductor laser integrated with Electro-absorption modulator to realize the narrow pulse width, high repetition rate of the seed source, and then using a two-cascaded high gain fiber amplifier as amplification mean, to realize the fibre-optical pulse laser with pulse width 3ns, pulse frequency 200kHz and peak power 1kW. According to the space laser atmospheric transmission window, the wavelength selects for 1.06um. It is adopted that full fibre technology to make seed source and amplification, pumping source and amplification of free-space coupled into fiber-coupled way. It can overcome that fibre lasers are vulnerable to changes in external conditions such as vibration, temperature drift and other factors affect, improving long-term stability. The fiber lasers can be modulated by PPM mode, to realize high rate modulation, because of its peak power, high transmission rate, narrow pulse width, high frequency stability, all technical indexes meet the requirements of the exploration of deep space communication technology.

  15. Effect of Pulse Width on Microstructure and Hardness of FeSiB Coatings by Laser Cladding

    Directory of Open Access Journals (Sweden)

    GONG Yu-bing

    2018-03-01

    Full Text Available High-density coating with FeSiB amorphous ribbons as cladding materials on the surface of mild steel was fabricated by laser cladding. The effect of different pulse widths on formability, microstructure and microhardness of the coatings was analyzed by optical microscope(OM, X-ray diffractometer (XRD, scanning electron microscope (SEM and microhardness tester. The results show that with the increase of the pulse width, the coating dilute rate rises; the tendency of crack increases and the crack originates from surface to the interface; the degree of crystallization increases and crystallization phases are α-Fe, Fe2B and Fe3Si, fusion zone width increases and the trend of columnar crystals along the epitaxial growth becomes bigger and bigger; the microhardness firstly increases and then decreases. When pulse width is 3.2ms, the structure of the coating is compact, no hole defects, the interface exhibits a good metallurgical combination and the dilute rate is low about 23.2%. Average microhardness of the coating reaches 1192HV, which is about 10 times as much as the substrate.

  16. Liquid mixing enhanced by pulse width modulation in a Y-shaped jet configuration

    Science.gov (United States)

    Xia, Qingfeng; Zhong, Shan

    2013-04-01

    In this paper, mixing between two fluid streams, which are injected into a planar mixing channel via a Y-shaped confluence section at the same volume flow rate, is studied experimentally. The injection of the two fluid streams is controlled by two separate solenoid valves, which are operated with a phase difference of 180°, using pulse width modulation. The experiments are conducted using water at a mean Reynolds number between 83 and 250, a range of pulsation frequencies and two duty cycles (25 and 50%). Both particle-image velocimetry and planar laser-induced fluorescence technique are used to visualize the flow patterns and to quantify the mixing degree in the mixing channel. This experiment shows that the pulsation of each jet produces vortical structures, which promotes mixing via vortex entrainment and vortex breakup, and at the same time the mixing is also greatly enhanced by sequential segmentation produced by a 180° out-of-phase pulsation of the two jets. This mixing enhancement method is effective at a Reynolds number greater than 125 with a mixing degree of 0.9 being achieved. For the Reynolds numbers studied in the present experiments, an optimal frequency exists, which corresponds to a Strouhal number in the range of 0.5-2. Furthermore, at a given mean Reynolds number a lower duty cycle is found to produce a better mixing due to the resultant higher instantaneous Reynolds number in the jet flow. It is also found that pulsation of only one jet can produce a similar mixing effect.

  17. Liquid mixing enhanced by pulse width modulation in a Y-shaped jet configuration

    Energy Technology Data Exchange (ETDEWEB)

    Xia Qingfeng; Zhong Shan, E-mail: shan.zhong@manchester.ac.uk [School of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL (United Kingdom)

    2013-04-15

    In this paper, mixing between two fluid streams, which are injected into a planar mixing channel via a Y-shaped confluence section at the same volume flow rate, is studied experimentally. The injection of the two fluid streams is controlled by two separate solenoid valves, which are operated with a phase difference of 180 Degree-Sign , using pulse width modulation. The experiments are conducted using water at a mean Reynolds number between 83 and 250, a range of pulsation frequencies and two duty cycles (25 and 50%). Both particle-image velocimetry and planar laser-induced fluorescence technique are used to visualize the flow patterns and to quantify the mixing degree in the mixing channel. This experiment shows that the pulsation of each jet produces vortical structures, which promotes mixing via vortex entrainment and vortex breakup, and at the same time the mixing is also greatly enhanced by sequential segmentation produced by a 180 Degree-Sign out-of-phase pulsation of the two jets. This mixing enhancement method is effective at a Reynolds number greater than 125 with a mixing degree of 0.9 being achieved. For the Reynolds numbers studied in the present experiments, an optimal frequency exists, which corresponds to a Strouhal number in the range of 0.5-2. Furthermore, at a given mean Reynolds number a lower duty cycle is found to produce a better mixing due to the resultant higher instantaneous Reynolds number in the jet flow. It is also found that pulsation of only one jet can produce a similar mixing effect. (paper)

  18. The effect of pulse width and contact configuration on paresthesia coverage in spinal cord stimulation.

    Science.gov (United States)

    Holsheimer, Jan; Buitenweg, Jan R; Das, John; de Sutter, Paul; Manola, Ljubomir; Nuttin, Bart

    2011-05-01

    In spinal cord stimulation for the management of chronic, intractable pain, a satisfactory analgesic effect can be obtained only when the stimulation-induced paresthesias cover all painful body areas completely or partially. To investigate the effect of stimulus pulse width (PW) and contact configuration (CC) on the area of paresthesia (PA), perception threshold (VPT), discomfort threshold (VDT), and usage range (UR) in spinal cord stimulation. Chronic pain patients were tested during a follow-up visit. They were stimulated monopolarly and with the CC giving each patient the best analgesia. VPT, VDT, and UR were determined for PWs of 90, 210, and 450 microseconds. The paresthesia contours at VDT were drawn on a body map and digitized; PA was calculated; and its anatomic composition was described. The effects of PW and CC on PA, VPT, VDT, and UR were tested statistically. Twenty-four of 31 tests with low thoracic stimulation and 8 of 9 tests with cervical stimulation gave a significant extension of PA at increasing PW. In 14 of 18 tests (low thoracic), a caudal extension was obtained (primarily in L5-S2). In cervical stimulation the extension was predominantly caudal as well. In contrast to VPT and VDT, UR is not significantly different when stimulating with any CC. PA extends caudally with increasing PW. The mechanism includes that the larger and smaller dorsal column fibers have a different mediolateral distribution and that smaller dorsal column fibers have a smaller UR and can be activated only when PW is sufficiently large. A similar effect of CC on PA is unlikely as long as electrodes with a large intercontact distance are applied.

  19. Effect of second harmonic in pulse-width-modulation-based DAC for feedback of digital fluxgate magnetometer

    Science.gov (United States)

    Belyayev, Serhiy; Ivchenko, Nickolay

    2018-04-01

    Digital fluxgate magnetometers employ processing of the measured pickup signal to produce the value of the compensation current. Using pulse-width modulation with filtering for digital to analog conversion is a convenient approach, but it can introduce an intrinsic source of nonlinearity, which we discuss in this design note. A code shift of one least significant bit changes the second harmonic content of the pulse train, which feeds into the pick-up signal chain despite the heavy filtering. This effect produces a code-dependent nonlinearity. This nonlinearity can be overcome by the specific design of the timing of the pulse train signal. The second harmonic is suppressed if the first and third quarters of the excitation period pulse train are repeated in the second and fourth quarters. We demonstrate this principle on a digital magnetometer, achieving a magnetometer noise level corresponding to that of the sensor itself.

  20. Analysis and Minimization of Output Current Ripple for Discontinuous Pulse-Width Modulation Techniques in Three-Phase Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2016-05-01

    Full Text Available This paper gives the complete analysis of the output current ripple in three-phase voltage source inverters considering the different discontinuous pulse-width modulation (DPWM strategies. In particular, peak-to-peak current ripple amplitude is analytically evaluated over the fundamental period and compared among the most used DPWMs, including positive and negative clamped (DPWM+ and DPWM−, and the four possible combinations between them, usually named as DPWM0, DPWM1, DPWM2, and DPWM3. The maximum and the average values of peak-to-peak current ripple are estimated, and a simple method to correlate the ripple envelope with the ripple rms is proposed and verified. Furthermore, all the results obtained by DPWMs are compared to the centered pulse-width modulation (CPWM, equivalent to the space vector modulation to identify the optimal pulse-width modulation (PWM strategy as a function of the modulation index, taking into account the different average switching frequency. In this way, the PWM technique providing for the minimum output current ripple is identified over the whole modulation range. The analytical developments and the main results are experimentally verified by current ripple measurements with a three-phase PWM inverter prototype supplying an induction motor load.

  1. The theory and implementation of a high quality pulse width modulated waveform synthesiser applicable to voltage FED inverters

    Science.gov (United States)

    Lower, Kim Nigel

    1985-03-01

    Modulation processes associated with the digital implementation of pulse width modulation (PWM) switching strategies were examined. A software package based on a portable turnkey structure is presented. Waveform synthesizer implementation techniques are reviewed. A three phase PWM waveform synthesizer for voltage fed inverters was realized. It is based on a constant carrier frequency of 18 kHz and a regular sample, single edge, asynchronous PWM switching scheme. With high carrier frequencies, it is possible to utilize simple switching strategies and as a consequence, many advantages are highlighted, emphasizing the importance to industrial and office markets.

  2. A Temperature-Hardened Sensor Interface with a 12-Bit Digital Output Using a Novel Pulse Width Modulation Technique

    Directory of Open Access Journals (Sweden)

    Emna Chabchoub

    2018-04-01

    Full Text Available A fully integrated sensor interface for a wide operational temperature range is presented. It translates the sensor signal into a pulse width modulated (PWM signal that is then converted into a 12-bit digital output. The sensor interface is based on a pair of injection locked oscillators used to implement a differential time-domain architecture with low sensitivity to temperature variations. A prototype has been fabricated using a 180 nm partially depleted silicon-on-insulator (SOI technology. Experimental results demonstrate a thermal stability as low as 65 ppm/°C over a large temperature range from −20 °C up to 220 °C.

  3. Application of chaotic pulse width modulation control for suppressing electromagnetic interference in a half-bridge converter

    Directory of Open Access Journals (Sweden)

    Yuhong Song

    2014-08-01

    Full Text Available It was proposed in the former research that chaos control can be used to suppress electromagnetic interference (EMI in DC–DC converters. Analysis on a half-bridge converter is detailed in this study. Here, the practical example of the power supply of personal computers is given to show that, with an external chaotic signal to a pulse width modulation control circuit, the proposed approach can reduce EMI by reducing the amplitudes of power signals such as transformer current and output inductor currents at multiples of fundamental frequency.

  4. PSCAD modeling of a two-level space vector pulse width modulation algorithm for power electronics education

    Directory of Open Access Journals (Sweden)

    Ahmet Mete Vural

    2016-09-01

    Full Text Available This paper presents the design details of a two-level space vector pulse width modulation algorithm in PSCAD that is able to generate pulses for three-phase two-level DC/AC converters with two different switching patterns. The presented FORTRAN code is generic and can be easily modified to meet many other kinds of space vector modulation strategies. The code is also editable for hardware programming. The new component is tested and verified by comparing its output as six gating signals with those of a similar component in MATLAB library. Moreover the component is used to generate digital signals for closed-loop control of STATCOM for reactive power compensation in PSCAD. This add-on can be an effective tool to give students better understanding of the space vector modulation algorithm for different control tasks in power electronics area, and can motivate them for learning.

  5. Design and Simulation of Control Technique for Permanent Magnet Synchronous Motor Using Space Vector Pulse Width Modulation

    Science.gov (United States)

    Khan, Mansoor; Yong, Wang; Mustafa, Ehtasham

    2017-07-01

    After the rapid advancement in the field of power electronics devices and drives for last few decades, there are different kinds of Pulse Width Modulation techniques which have been brought to the market. The applications ranging from industrial appliances to military equipment including the home appliances. The vey common application for the PWM is three phase voltage source inverter, which is used to convert DC to AC in the homes to supply the power to the house in case electricity failure, usually named as Un-interrupted Power Supply. In this paper Space Vector Pulse Width Modulation techniques is discussed and analysed under the control technique named as Field Oriented Control. The working and implementation of this technique has been studied by implementing on the three phase bridge inverter. The technique is used to control the Permanente Magnet Synchronous Motor. The drive system is successfully implemented in MATLAB/Simulink using the mathematical equation and algorithm to achieve the satisfactory results. PI type of controller is used to tuned ers of the motothe parametr i.e. torque and current.

  6. Four-deep charge-time and pulse-width scaling discriminator for delay line MWPC's

    International Nuclear Information System (INIS)

    Lee, K.L.; Kirsten, F.A.; Grigorian, A.; Guiragossian, Z.G.T.

    1976-01-01

    A discriminator has been developed for digitizing both intercepted total charge and location of electromagnetic shower and particle trajectories in multi-wire proportional chambers read by delay lines. Determination of shower trajectory is aided by video signal integration followed by centroid-locating discrimination. Calibrated run-down of the signal integrating capacitor gives the charge information above a given threshold level. The discriminator is designed to handle up to four shower-induced video signals per event by incorporating steering circuits within the module. Each video signal is examined for time over an adjustable threshold. Video pulses with separation of less than 20 nsec are treated as a single pulse. Counter-logic circuits indicate the number of video signals digitized. These signal processing circuits provide a first level of data sifting which otherwise must be carried out with additional discriminator channels and added complexity in data recognition

  7. Pulse width modulated push-pull driven parallel resonant converter with active free-wheel

    Science.gov (United States)

    Reass, William A.; Schrank, Louis

    2004-06-22

    An apparatus and method for high frequency alternating power generation to control kilowatts of supplied power in microseconds. The present invention includes a means for energy storage, push-pull switching means, control electronics, transformer means, resonant circuitry and means for excess energy recovery, all in electrical communication. A push-pull circuit works synchronously with a force commutated free-wheel transistor to provide current pulses to a transformer. A change in the conduction angle of the push-pull circuit changes the amount of energy coupled into the transformer's secondary oscillating circuit, thereby altering the induced secondary resonating voltage. At the end of each pulse, the force commutated free-wheel transistor causes residual excess energy in the primary circuit to be transmitted back to the storage capacitor for later use.

  8. Position and width of normal adult optic chiasm as measured in coronal MRI

    International Nuclear Information System (INIS)

    Kim, Myung Soon; Park, Jin Sook

    1994-01-01

    To evaluate the position and transverse dimension of the adult optic chiasm in normal Korean adult. The authors analysed 3D coronal volume images (TR/TE=30/13, flip angle=30 .deg. ) of 136 normal adult subjects without known visual abnormality. All MRI examinations were performed using a 0.5T system. MRI was reviewed retrospectively to determine the position (horizontal and tilted) of the potic chiosm and the transverse dimension of the optic chiasm was measured. Seventy- five (55%) of the 136 normal subjects had horizontal position, and sixty-one (45%) had tilted position. Thirty- eight (62%) of 61 with tilted position showed higher position on the right side, and twenty-three (38%) showed higher position on the side. The average transverse dimension(mean SD) was 15.2 ± 0.7mm in men and 14.6 ± 1.0mm in women. The difference of transverse dimension between men and women was statistically significant. Tilted position of the adult optic chiasm on coronal MRI was seen in approximately half of normal adults. The average of transverse dimension of normal optic chiasm was 15mm

  9. Short-Pulse-Width Repetitively Q-Switched ~2.7-μm Er:Y2O3 Ceramic Laser

    Directory of Open Access Journals (Sweden)

    Xiaojing Ren

    2017-11-01

    Full Text Available A short-pulse-width repetitively Q-switched 2.7-μm Er:Y2O3 ceramic laser is demonstrated using a specially designed mechanical switch, a metal plate carved with slits of both slit-width and duty-cycle optimized. With a 20% transmission output coupler, stable pulse trains with durations (full-width at half-maximum, FWHM of 27–38 ns were generated with a repetition rate within the range of 0.26–4 kHz. The peak power at a 0.26 kHz repetition rate was ~3 kW.

  10. Short-pulse-width micromachining of hard materials using DPSS Nd:YAG lasers

    Science.gov (United States)

    Heglin, Michael; Govorkov, Sergei V.; Scaggs, Michael J.; Theoharidis, Haris; Schoelzel, T.

    2002-06-01

    The material processing of an industrial, short-pulse duration DPPS YAG laser producing peak powers greater than 0.2MW is discussed in this paper. This peak power provides sufficient materials processing capability to meet the micro machining needs in the automotive, semiconductor, micro- electronic, medical and telecommunication industries. All hard and soft materials including: plastics, metals, ceramics, diamond and other crystalline materials are suitable candidates for the processing capability of this laser. Micro level features can be machined in these materials to a depth in excess of 1mm with high quality results. In most applications feature sizes can be achieved that are not possible or economical with existing technologies. The optical beam delivery system requirements, and overall micro-machining set-up are also described. The drilling and cutting versatility down to feature sizes of less than 7 micrometers , as well as, complex shapes are shown. The wavelength, pulse length, and peakpower are described and relate to their effect on recast, micro-cracking and material removal rates. Material removal effects related to progressive penetration into the material will be reviewed. The requirements of this DPSS laser technology to meet the operational requirements for high duty cycle operation in industrial environments is covered along with processing flexibility and lower operating cost.

  11. A Simulation of the Effects of Varying Repetition Rate and Pulse Width of Nanosecond Discharges on Premixed Lean Methane-Air Combustion

    Directory of Open Access Journals (Sweden)

    Moon Soo Bak

    2012-01-01

    Full Text Available Two-dimensional kinetic simulation has been carried out to investigate the effects of repetition rate and pulse width of nanosecond repetitively pulsed discharges on stabilizing premixed lean methane-air combustion. The repetition rate and pulse width are varied from 10 kHz to 50 kHz and from 9 ns to 2 ns while the total power is kept constant. The lower repetition rates provide larger amounts of radicals such as O, H, and OH. However, the effect on stabilization is found to be the same for all of the tested repetition rates. The shorter pulse width is found to favor the production of species in higher electronic states, but the varying effects on stabilization are also found to be small. Our results indicate that the total deposited power is the critical element that determines the extent of stabilization over this range of discharge properties studied.

  12. Zero-voltage DC/DC converter with asymmetric pulse-width modulation for DC micro-grid system

    Science.gov (United States)

    Lin, Bor-Ren

    2018-04-01

    This paper presents a zero-voltage switching DC/DC converter for DC micro-grid system applications. The proposed circuit includes three half-bridge circuit cells connected in primary-series and secondary-parallel in order to lessen the voltage rating of power switches and current rating of rectifier diodes. Thus, low voltage stress of power MOSFETs can be adopted for high-voltage input applications with high switching frequency operation. In order to achieve low switching losses and high circuit efficiency, asymmetric pulse-width modulation is used to turn on power switches at zero voltage. Flying capacitors are used between each circuit cell to automatically balance input split voltages. Therefore, the voltage stress of each power switch is limited at Vin/3. Finally, a prototype is constructed and experiments are provided to demonstrate the circuit performance.

  13. Three-dimensional shape profiling by out-of-focus projection of colored pulse width modulation fringe patterns.

    Science.gov (United States)

    Silva, Adriana; Flores, Jorge L; Muñoz, Antonio; Ayubi, Gastón A; Ferrari, José A

    2017-06-20

    Three-dimensional (3D) shape profiling by sinusoidal phase-shifting methods is affected by the non-linearity of the projector. To overcome this problem, the defocusing technique has become an important alternative to generate sinusoidal fringe patterns. The precision of this method depends on the binary pattern used and on the defocusing applied. To improve the defocusing technique, we propose the implementation of a color-based binary fringe patterns. The proposed technique involves the generation of colored pulse width modulation (PWM) fringe patterns, which are generated with different frequencies at the carrier signal. From an adequate selection of these frequencies, the colored PWM fringe patterns will lead to amplitude harmonics lower than the conventional PWM fringe patterns. Hence, the defocusing can decrease, and the 3D shape profiling can be more accurate. Numerical simulations and experimental results are presented as validation.

  14. Effects of interventions on normalizing step width during self-paced dual-belt treadmill walking with virtual reality, a randomised controlled trial.

    Science.gov (United States)

    Oude Lansink, I L B; van Kouwenhove, L; Dijkstra, P U; Postema, K; Hijmans, J M

    2017-10-01

    Step width is increased during dual-belt treadmill walking, in self-paced mode with virtual reality. Generally a familiarization period is thought to be necessary to normalize step width. The aim of this randomised study was to analyze the effects of two interventions on step width, to reduce the familiarization period. We used the GRAIL (Gait Real-time Analysis Interactive Lab), a dual-belt treadmill with virtual reality in the self-paced mode. Thirty healthy young adults were randomly allocated to three groups and asked to walk at their preferred speed for 5min. In the first session, the control-group received no intervention, the 'walk-on-the-line'-group was instructed to walk on a line, projected on the between-belt gap of the treadmill and the feedback-group received feedback about their current step width and were asked to reduce it. Interventions started after 1min and lasted 1min. During the second session, 7-10days later, no interventions were given. Linear mixed modeling showed that interventions did not have an effect on step width after the intervention period in session 1. Initial step width (second 30s) of session 1 was larger than initial step width of session 2. Step width normalized after 2min and variation in step width stabilized after 1min. Interventions do not reduce step width after intervention period. A 2-min familiarization period is sufficient to normalize and stabilize step width, in healthy young adults, regardless of interventions. A standardized intervention to normalize step width is not necessary. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Pulse width modulated buck-boost five-level current source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.

    2008-01-01

    , resulting in the natural balance of input current. For maintaining the normalized volt-sec average unchanged, the alternative phase opposition disposition (APOD) modulation scheme with typical gating signal mapping technique from voltage source inverter (VSI) to CSI can be assumed to control the five......This paper presents new five-level current source inverters (CSIs) with voltage/current buck-boost capability. Being different from the existing multilevel CSI, the proposed CSIs were first designed to regulate the flowing path of dc input current by controlling two additional active switches......-level buck-boost CSIs. Next by observing the hidden current charging path during inductive charging interval under APOD modulation, it is noted that the buck-boost five-level CSI can then be further modified with lesser active component without degrading output performance. To verify the theoretical findings...

  16. A two-level voltage source inverter with differentially sinusoidal pulse width modulation used in the interconnection system of a wind turbine generator

    Directory of Open Access Journals (Sweden)

    Alexandros C. Charalampidis

    2014-10-01

    Full Text Available This study analyses an interconnection system based on differentially sinusoidal pulse width modulation, used for the interconnection to the grid of a variable speed wind turbine. The modulation technique used provides specific advantages in comparison with the commonly used sinusoidal pulse width modulation (SPWM technique, such as lower DC bus voltage requirements, smaller switching losses for the same switching frequency as well as less higher harmonic content in the voltage waveforms produced. The respective control system is also described in detail. Thus this study provides a guide enabling the design of any interconnection system based on this modulation technique.

  17. Effect of acute intraocular pressure elevation on the minimum rim width in normal, ocular hypertensive and glaucoma eyes.

    Science.gov (United States)

    Sharma, Sourabh; Tun, Tin A; Baskaran, Mani; Atalay, Eray; Thakku, Sri Gowtham; Liang, Zhang; Milea, Dan; Strouthidis, Nicholas G; Aung, Tin; Girard, Michael Ja

    2018-01-01

    To estimate and compare changes in the Bruch's membrane opening-minimum rim width (BMO-MRW) and area in normal, ocular hypertensive and glaucoma eyes following acute elevations in intraocular pressure (IOP). The optic nerve heads (ONHs) of 104 subjects (31 normals, 20 ocular hypertension (OHT) and 53 with primary glaucoma) were imaged using Spectral-domain optical coherence tomography (OCT; Spectralis, Heidelberg Engineering, Germany). IOP was raised twice by applying a force (0.64 n then 0.9 n) to the anterior sclera using an ophthalmo-dynamometer. After each IOP increment, IOP was held constant, measured with a Tonopen (AVIA applanation tonometer, Reichert, Depew, New York, USA), and ONH was rescanned with OCT. In each OCT volume, BMO-MRW and area were calculated and at each IOP increment. The baseline MRW was significantly smaller in glaucoma subjects (174.3±54.3 µm) compared with normal (287.4±42.2 µm, pglaucoma subjects was significantly thinner at the first and second IOP elevations than that at baseline (both p0.05). Acute IOP elevation leads to compression of the nerve fibre layers of neuroretinal rim in glaucoma subjects only without changing ONH size. This suggests that the neural and connective tissues at ONH level in glaucoma subjects are more susceptible to acute IOP episodes than OHT or normal controls. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Modified Synchronous Reference Frame Based Shunt Active Power Filter with Fuzzy Logic Control Pulse Width Modulation Inverter

    Directory of Open Access Journals (Sweden)

    Suleiman Musa

    2017-05-01

    Full Text Available Harmonic distortion in power networks has greatly reduced power quality and this affects system stability. In order to mitigate this power quality issue, the shunt active power filter (SAPF has been widely applied and it is proven to be the best solution to current harmonics. This paper evaluates the performance of the modified synchronous reference frame extraction (MSRF algorithm with fuzzy logic controller (FLC based current control pulse width modulation (PWM inverter of three-phase three-wire SAPF to mitigate current harmonics. The proposed FLC is designed with a reduced amount of membership functions (MFs and rules, and thus significantly reduces the computational time and memory size. Modeling and simulations of SAPF are carried out using MATLAB/Simulink R2012a with the power system toolbox under steady-state condition, and this is followed with hardware implementation using a TMS320F28335 digital signal processor (DSP, Specrum Digital Inc., Stafford, TX, USA. The results obtained demonstrate a good and satisfactory response to mitigate the harmonics in the system. The total harmonic distortion (THD for the system has been reduced from 25.60% to 0.92% and 1.41% in the simulation study with and without FLC, respectively. Similarly for the experimental study, the SAPF can compensate for the three-phase load current by reducing THD to 5.07% and 7.4% with and without FLC, respectively.

  19. Virtual-vector-based space vector pulse width modulation of the DC-AC multilevel-clamped multilevel converter (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Busquets-Monge, Sergio; Blaabjerg, Frede

    2011-01-01

    This work presents the development of the space vector pulse width modulation (SVPWM) of a new multi-level converter topology. First, the proposed converter and its natural space vector diagram are presented. Secondly, a modified space vector diagram based on the virtual-vectors technique is show...

  20. A frequency and pulse-width co-modulation strategy for transcutaneous neuromuscular electrical stimulation based on sEMG time-domain features

    Science.gov (United States)

    Zhou, Yu-Xuan; Wang, Hai-Peng; Bao, Xue-Liang; Lü, Xiao-Ying; Wang, Zhi-Gong

    2016-02-01

    Objective. Surface electromyography (sEMG) is often used as a control signal in neuromuscular electrical stimulation (NMES) systems to enhance the voluntary control and proprioceptive sensory feedback of paralyzed patients. Most sEMG-controlled NMES systems use the envelope of the sEMG signal to modulate the stimulation intensity (current amplitude or pulse width) with a constant frequency. The aims of this study were to develop a strategy that co-modulates frequency and pulse width based on features of the sEMG signal and to investigate the torque-reproduction performance and the level of fatigue resistance achieved with our strategy. Approach. We examined the relationships between wrist torque and two stimulation parameters (frequency and pulse width) and between wrist torque and two sEMG time-domain features (mean absolute value (MAV) and number of slope sign changes (NSS)) in eight healthy volunteers. By using wrist torque as an intermediate variable, customized and generalized transfer functions were constructed to convert the two features of the sEMG signal into the two stimulation parameters, thereby establishing a MAV/NSS dual-coding (MNDC) algorithm. Wrist torque reproduction performance was assessed by comparing the torque generated by the algorithms with that originally recorded during voluntary contractions. Muscle fatigue was assessed by measuring the decline percentage of the peak torque and by comparing the torque time integral of the response to test stimulation trains before and after fatigue sessions. Main Results. The MNDC approach could produce a wrist torque that closely matched the voluntary wrist torque. In addition, a smaller decay in the wrist torque was observed after the MNDC-coded fatigue stimulation was applied than after stimulation using pulse-width modulation alone. Significance. Compared with pulse-width modulation stimulation strategies that are based on sEMG detection, the MNDC strategy is more effective for both voluntary muscle

  1. Comparison of Bruch's Membrane Opening-Minimum Rim Width among Those with Normal Ocular Health by Race

    Science.gov (United States)

    Rhodes, Lindsay A.; Huisingh, Carrie E.; Quinn, Adam E.; McGwin, Gerald; LaRussa, Frank; Box, Daniel; Owsley, Cynthia; Girkin, Christopher A.

    2016-01-01

    Purpose To examine if racial differences in Bruch's membrane opening-minimum rim width (BMO-MRW) in spectral domain optical coherence tomography (SDOCT) exist, specifically between people of African descent (AD) and European descent (ED) in normal ocular health. Design Cross-sectional study Methods Patients presenting for a comprehensive eye exam at retail-based primary eye clinics were enrolled based on ≥1 of the following at-risk criteria for glaucoma: AD aged ≥ 40 years, ED aged ≥50 years, diabetes, family history of glaucoma, and/or preexisting diagnosis of glaucoma. Participants with normal optic nerves on exam received SDOCT of the optic nerve head (24 radial scans). Global and regional (temporal, superotemporal, inferotemporal, nasal, superonasal, and inferonasal) BMO-MRW were measured and compared by race using generalized estimating equations. Models were adjusted for age, gender, and BMO area. Results SDOCT scans from 269 eyes (148 participants) were included in the analysis. Mean global BMO-MRW declined as age increased. After adjusting for age, gender, and BMO area, there was not a statistically significant difference in mean global BMO-MRW by race (P = 0.60). Regionally, the mean BMO-MRW was lower in the crude model among AD eyes in the temporal, superotemporal, and nasal regions and higher in the inferotemporal, superonasal, and inferonasal regions. However, in the adjusted model, these differences were not statistically significant. Conclusions BMO-MRW was not statistically different between those of AD and ED. Race-specific normative data may not be necessary for the deployment of BMO-MRW in AD patients. PMID:27825982

  2. Analyzing the effectiveness of flare dispensing programs against pulse width modulation seekers using self-organizing maps

    Science.gov (United States)

    Şahingil, Mehmet C.; Aslan, Murat Š.

    2013-10-01

    Infrared guided missile seekers utilizing pulse width modulation in target tracking is one of the threats against air platforms. To be able to achieve a "soft-kill" protection of own platform against these type of threats, one needs to examine carefully the seeker operating principle with its special electronic counter-counter measure (ECCM) capability. One of the cost-effective ways of soft kill protection is to use flare decoys in accordance with an optimized dispensing program. Such an optimization requires a good understanding of the threat seeker, capabilities of the air platform and engagement scenario information between them. Modeling and simulation is very powerful tool to achieve a valuable insight and understand the underlying phenomenology. A careful interpretation of simulation results is crucial to infer valuable conclusions from the data. In such an interpretation there are lots of factors (features) which affect the results. Therefore, powerful statistical tools and pattern recognition algorithms are of special interest in the analysis. In this paper, we show how self-organizing maps (SOMs), which is one of those powerful tools, can be used in analyzing the effectiveness of various flare dispensing programs against a PWM seeker. We perform several Monte Carlo runs for a typical engagement scenario in a MATLAB-based simulation environment. In each run, we randomly change the flare dispending program and obtain corresponding class: "successful" or "unsuccessful", depending on whether the corresponding flare dispensing program deceives the seeker or not, respectively. Then, in the analysis phase, we use SOMs to interpret and visualize the results.

  3. Numerical analysis of breakdown dynamics dependence on pulse width in laser-induced damage in fused silica: Role of optical system

    Science.gov (United States)

    Hamam, Kholoud A.; Gamal, Yosr E. E.-D.

    2018-06-01

    We report a numerical investigation of the breakdown and damage in fused silica caused by ultra-short laser pulses. The study based on a modified model (Gaabour et al., 2012) that solves the rate equation numerically for the electron density evolution during the laser pulse, under the combined effect of both multiphoton and electron impact ionization processes. Besides, electron loss processes due to diffusion out of the focal volume and recombination are also considered in this analysis. The model is applied to investigate the threshold intensity dependence on laser pulse width in the experimental measurements that are given by Liu et al. (2005). In this experiment, a Ti-sapphire laser source operating at 800 nm with pulse duration varies between 240 fs and 2.5 ps is used to irradiate a bulk of fused silica with dimensions 10 × 5 × 3 mm. The laser beam was focused into the bulk using two optical systems with effective numerical apertures (NA) 0.126 and 0.255 to give beam spot radius at the focus of the order 2.0 μm and 0.95 μm respectively. Reasonable agreement between the calculated thresholds and the measured ones is attained. Moreover, a study is performed to examine the respective role of the physical processes of the breakdown of fused silica in relation to the pulse width and focusing optical system. The analysis revealed a real picture of the location and size of the generated plasma.

  4. Advanced Macro-Model with Pulse-Width Dependent Switching Characteristic for Spin Transfer Torque Based Magnetic-Tunnel-Junction Elements

    Science.gov (United States)

    Sojeong Kim,; Seungjun Lee,; Hyungsoon Shin,

    2010-04-01

    In spin transfer torque (STT)-based magnetic tunnel junction (MTJ), the switching depends on the current pulse-width as well as the magnitude of the switching current. We present an advanced macro-model of an STT-MTJ for a circuit simulator such as HSPICE. The macro-model can simulate the dependence of switching behavior on current pulse-width in an STT-MTJ. An imaginary resistor-capacitor (RC) circuit is adopted to emulate complex timing behavior which cannot be described nicely by existing functions in HSPICE. Simulation results show the resistance-current (R-I) curve and timing behavior is in good agreement with the experimental data.

  5. Self-focusing of optical pulses in media with normal dispersion

    DEFF Research Database (Denmark)

    Bergé, L.; Kuznetsov, E.A.; Juul Rasmussen, J.

    1996-01-01

    The self-focusing of ultra short optical pulses in a nonlinear medium with normal (i.e., negative) group-velocity dispersion is investigated. By using a combination of various techniques like virial-type arguments and self-similar transformations, we obtain strong evidence suggesting that a pulse...

  6. Radiobiological influence of megavoltage electron pulses of ultra-high pulse dose rate on normal tissue cells.

    Science.gov (United States)

    Laschinsky, Lydia; Karsch, Leonhard; Leßmann, Elisabeth; Oppelt, Melanie; Pawelke, Jörg; Richter, Christian; Schürer, Michael; Beyreuther, Elke

    2016-08-01

    Regarding the long-term goal to develop and establish laser-based particle accelerators for a future radiotherapeutic treatment of cancer, the radiobiological consequences of the characteristic short intense particle pulses with ultra-high peak dose rate, but low repetition rate of laser-driven beams have to be investigated. This work presents in vitro experiments performed at the radiation source ELBE (Electron Linac for beams with high Brilliance and low Emittance). This accelerator delivered 20-MeV electron pulses with ultra-high pulse dose rate of 10(10) Gy/min either at the low pulse frequency analogue to previous cell experiments with laser-driven electrons or at high frequency for minimizing the prolonged dose delivery and to perform comparison irradiation with a quasi-continuous electron beam analogue to a clinically used linear accelerator. The influence of the different electron beam pulse structures on the radiobiological response of the normal tissue cell line 184A1 and two primary fibroblasts was investigated regarding clonogenic survival and the number of DNA double-strand breaks that remain 24 h after irradiation. Thereby, no considerable differences in radiation response were revealed both for biological endpoints and for all probed cell cultures. These results provide evidence that the radiobiological effectiveness of the pulsed electron beams is not affected by the ultra-high pulse dose rates alone.

  7. Radiobiological influence of megavoltage electron pulses of ultra-high pulse dose rate on normal tissue cells

    International Nuclear Information System (INIS)

    Laschinsky, Lydia; Karsch, Leonhard; Schuerer, Michael; Lessmann, Elisabeth; Beyreuther, Elke; Oppelt, Melanie; Pawelke, Joerg; Richter, Christian

    2016-01-01

    Regarding the long-term goal to develop and establish laser-based particle accelerators for a future radiotherapeutic treatment of cancer, the radiobiological consequences of the characteristic short intense particle pulses with ultra-high peak dose rate, but low repetition rate of laser-driven beams have to be investigated. This work presents in vitro experiments performed at the radiation source ELBE (Electron Linac for beams with high Brilliance and low Emittance). This accelerator delivered 20-MeV electron pulses with ultra-high pulse dose rate of 10"1"0 Gy/min either at the low pulse frequency analogue to previous cell experiments with laser-driven electrons or at high frequency for minimizing the prolonged dose delivery and to perform comparison irradiation with a quasi-continuous electron beam analogue to a clinically used linear accelerator. The influence of the different electron beam pulse structures on the radiobiological response of the normal tissue cell line 184A1 and two primary fibroblasts was investigated regarding clonogenic survival and the number of DNA double-strand breaks that remain 24 h after irradiation. Thereby, no considerable differences in radiation response were revealed both for biological endpoints and for all probed cell cultures. These results provide evidence that the radiobiological effectiveness of the pulsed electron beams is not affected by the ultra-high pulse dose rates alone. (orig.)

  8. Numerical analysis of breakdown dynamics dependence on pulse width in laser-induced damage in fused silica: Role of optical system

    Directory of Open Access Journals (Sweden)

    Kholoud A. Hamam

    2018-06-01

    Full Text Available We report a numerical investigation of the breakdown and damage in fused silica caused by ultra-short laser pulses. The study based on a modified model (Gaabour et al., 2012 that solves the rate equation numerically for the electron density evolution during the laser pulse, under the combined effect of both multiphoton and electron impact ionization processes. Besides, electron loss processes due to diffusion out of the focal volume and recombination are also considered in this analysis. The model is applied to investigate the threshold intensity dependence on laser pulse width in the experimental measurements that are given by Liu et al. (2005. In this experiment, a Ti-sapphire laser source operating at 800 nm with pulse duration varies between 240 fs and 2.5 ps is used to irradiate a bulk of fused silica with dimensions 10 × 5 × 3 mm. The laser beam was focused into the bulk using two optical systems with effective numerical apertures (NA 0.126 and 0.255 to give beam spot radius at the focus of the order 2.0 μm and 0.95 μm respectively. Reasonable agreement between the calculated thresholds and the measured ones is attained. Moreover, a study is performed to examine the respective role of the physical processes of the breakdown of fused silica in relation to the pulse width and focusing optical system. The analysis revealed a real picture of the location and size of the generated plasma. Keywords: Ultra-short laser pulses, Ablation mechanisms, Electron density, Electron loss processes, Avalanche ionization, Breakdown threshold

  9. The pulse-driven AC Josephson voltage normal

    International Nuclear Information System (INIS)

    Kieler, Oliver

    2016-01-01

    In this contribution quantum precise alternating-voltage sources are presented, which make the generation of arbitrary wave forms with highest spectral purity with a high bandwidth from DC up to the MHz range possible. Heartpiece of these Josephson voltage normals is a serial circuit of many thousand Josephson contacts, which make by irradiation with high-frequency radiation (microwaves) the generation of highly precise voltage values possible. Thereby in the current-voltage characteristics stages of constant voltage, so called Shapiro stages, occur. Illustratively these stages can be described by the transfer of a certain number of flux quanta through the Josephson contacts.

  10. Pulse splitting of self-focusing-beams in normally dispersive media

    DEFF Research Database (Denmark)

    Bergé, L.; Juul Rasmussen, J.

    1996-01-01

    The influence of the normal group-velocity dispersion on anisotropic self-focusing beams in nonlinear Kerr media is studied analytically. It is shown that a light pulse self-focusing in the presence of normal dispersion is split up into several small-scale cells preventing a catastrophic collapse....... The theoretical explanation of this splitting process is revealed....

  11. Too much or too little step width variability is associated with a fall history in older persons who walk at or near normal gait speed

    Directory of Open Access Journals (Sweden)

    Newman Anne B

    2005-07-01

    significant in individuals who walked Conclusion Extreme (either too little or too much step width variability is associated with falls in the past year in older persons who walk at or near normal gait speed and not in older persons who walk slowly (

  12. Pulse to pulse klystron diagnosis system

    International Nuclear Information System (INIS)

    Nowak, J.; Davidson, V.; Genova, L.; Johnson, R.; Reagan, D.

    1981-03-01

    This report describes a system used to study the behavior of SLAC high powered klystrons operating with a twice normal pulse width of 5 μs. At present, up to eight of the klystrons installed along the accelerator can be operated with long pulses and monitored by this system. The report will also discuss some of the recent findings and investigations

  13. Reduction of CSF flow artifact in fast fluid attenuated inversion recovery MR imaging. Study of excitation width in 180deg inversion pulse

    International Nuclear Information System (INIS)

    Tsuchihashi, Toshio; Yoshizawa, Satoshi; Maki, Toshio; Kitagawa, Matsuo; Suzuki, Ken; Fujita, Isao

    1998-01-01

    A technique that increases slice thickness so that it becomes wider than the excitation width of the 180deg inversion pulse and in which TR is partitioned twice has been investigated with regard to fast FLAIR. This is a technique that reduces the flow artifact of CSF. It is thought that, with this technique, the flow artifact is reduced because the CSF that flows onto the slice reaches the null point. The cross talk effect of the 180deg inversion pulse appears as a high CSF signal. As a result, the number of slices needs to be partitioned two or three times before imaging. Thus the imaging time is doubled or tripled. Considering the cross talk effect of the 180deg inversion pulse and the imaging time needed for this technique, the optimal imaging technique would be one that uses an inversion pulse that is four times slice thickness plus slice space and for which the number of slices is partitioned twice. Furthermore, the null point of CSF was dependent on dividing TR in half. (author)

  14. Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences

    DEFF Research Database (Denmark)

    Cohen, Eric R.; Rostrup, Egill; Sidaros, Karam

    2004-01-01

    to be more accurately localized and quantified based on changes in venous blood oxygenation alone. The normalized BOLD signal induced by the motor task was consistent across different magnetic fields and pulse sequences, and corresponded well with cerebral blood flow measurements. Our data suggest...... size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response...... for global stimulation, subjects breathed a 5% CO(2) gas mixture. Under all conditions, voxels containing primarily large veins and those containing primarily active tissue (i.e., capillaries and small veins) showed distinguishable behavior after hypercapnic normalization. This allowed functional activity...

  15. Breaking Through the Multi-Mesa-Channel Width Limited of Normally Off GaN HEMTs Through Modulation of the Via-Hole-Length.

    Science.gov (United States)

    Chien, Cheng-Yen; Wu, Wen-Hsin; You, Yao-Hong; Lin, Jun-Huei; Lee, Chia-Yu; Hsu, Wen-Ching; Kuan, Chieh-Hsiung; Lin, Ray-Ming

    2017-12-01

    We present new normally off GaN high-electron-mobility transistors (HEMTs) that overcome the typical limitations in multi-mesa-channel (MMC) width through modulation of the via-hole-length to regulate the charge neutrality screen effect. We have prepared enhancement-mode (E-mode) GaN HEMTs having widths of up to 300 nm, based on an enhanced surface pinning effect. E-mode GaN HEMTs having MMC structures and widths as well as via-hole-lengths of 100 nm/2 μm and 300 nm/6 μm, respectively, exhibited positive threshold voltages (V th ) of 0.79 and 0.46 V, respectively. The on-resistances of the MMC and via-hole-length structures were lower than those of typical tri-gate nanoribbon GaN HEMTs. In addition, the devices not only achieved the E-mode but also improved the power performance of the GaN HEMTs and effectively mitigated the device thermal effect. We controlled the via-hole-length sidewall surface pinning effect to obtain the E-mode GaN HEMTs. Our findings suggest that via-hole-length normally off GaN HEMTs have great potential for use in next-generation power electronics.

  16. Breaking Through the Multi-Mesa-Channel Width Limited of Normally Off GaN HEMTs Through Modulation of the Via-Hole-Length

    Science.gov (United States)

    Chien, Cheng-Yen; Wu, Wen-Hsin; You, Yao-Hong; Lin, Jun-Huei; Lee, Chia-Yu; Hsu, Wen-Ching; Kuan, Chieh-Hsiung; Lin, Ray-Ming

    2017-06-01

    We present new normally off GaN high-electron-mobility transistors (HEMTs) that overcome the typical limitations in multi-mesa-channel (MMC) width through modulation of the via-hole-length to regulate the charge neutrality screen effect. We have prepared enhancement-mode (E-mode) GaN HEMTs having widths of up to 300 nm, based on an enhanced surface pinning effect. E-mode GaN HEMTs having MMC structures and widths as well as via-hole-lengths of 100 nm/2 μm and 300 nm/6 μm, respectively, exhibited positive threshold voltages ( V th) of 0.79 and 0.46 V, respectively. The on-resistances of the MMC and via-hole-length structures were lower than those of typical tri-gate nanoribbon GaN HEMTs. In addition, the devices not only achieved the E-mode but also improved the power performance of the GaN HEMTs and effectively mitigated the device thermal effect. We controlled the via-hole-length sidewall surface pinning effect to obtain the E-mode GaN HEMTs. Our findings suggest that via-hole-length normally off GaN HEMTs have great potential for use in next-generation power electronics.

  17. Pulse wave imaging in normal, hypertensive and aneurysmal human aortas in vivo: a feasibility study

    International Nuclear Information System (INIS)

    Li, Ronny X; Luo, Jianwen; Shahmirzadi, Danial; Konofagou, Elisa E; Balaram, Sandhya K; Chaudhry, Farooq A

    2013-01-01

    Arterial stiffness is a well-established biomarker for cardiovascular risk, especially in the case of hypertension. The progressive stages of an abdominal aortic aneurysm (AAA) have also been associated with varying arterial stiffness. Pulse wave imaging (PWI) is a noninvasive, ultrasound imaging-based technique that uses the pulse wave-induced arterial wall motion to map the propagation of the pulse wave and measure the regional pulse wave velocity (PWV) as an index of arterial stiffness. In this study, the clinical feasibility of PWI was evaluated in normal, hypertensive, and aneurysmal human aortas. Radiofrequency-based speckle tracking was used to estimate the pulse wave-induced displacements in the abdominal aortic walls of normal (N = 15, mean age 32.5 ± 10.2 years), hypertensive (N = 13, mean age 60.8 ± 15.8 years), and aneurysmal (N = 5, mean age 71.6 ± 11.8 years) human subjects. Linear regression of the spatio-temporal variation of the displacement waveform in the anterior aortic wall over a single cardiac cycle yielded the slope as the PWV and the coefficient of determination r 2 as an approximate measure of the pulse wave propagation uniformity. The aortic PWV measurements in all normal, hypertensive, and AAA subjects were 6.03 ± 1.68, 6.69 ± 2.80, and 10.54 ± 6.52 m s −1 , respectively. There was no significant difference (p = 0.15) between the PWVs of the normal and hypertensive subjects while the PWVs of the AAA subjects were significantly higher (p 2 in the AAA subjects was significantly lower (p 2 ) obtained using PWI, in addition to the PWI images and spatio-temporal maps that provide qualitative visualization of the pulse wave, may potentially provide valuable information for the clinical characterization of aneurysms and other vascular pathologies that regionally alter the arterial wall mechanics. (paper)

  18. Nilai Rerata Vascular Pedicle Width, Vascular Pedicle-Cardiac Ratio Vascular Pedicle-Thoracic Ratio Orang Dewasa Normal Indonesia Studi di RS dr. Cipto Mangunkusomo

    Directory of Open Access Journals (Sweden)

    Rommy Zunera

    2016-03-01

    Full Text Available Vascular pedicle width (VPW adalah jarak tepi luar vena kava superior ke tepi luar arteri subklavia kiri. Pemeriksaan VPW di foto toraks bersifat non-invasif, cepat dan mudah untuk memprediksi hipervolemia.Penelitian ini bertujuan untuk mengetahui rerata nilai VPW orang dewasa normal Indonesia. VPW diukurdengan dua metode: pertama pengukuran VPW tunggal yang akurasinya terbatas di foto toraks digital karenarelatif tidak dipengaruhi faktor magnifikasi. Metode kedua untuk foto toraks nondigital yaitu pengukuranrasio:vascular pedicle-cardiac ratio (VPCR dan vascular pedicle-thoracic ratio (VPTR. Pengukuran serupadilakukan terhadap  topogram CT scan toraks AP terlentang dan CT scan toraks lalu dibandingkan akurasipengukuran di topogram dengan CT scan  toraks sebagai standar baku. Sampel terdiri atas 104 foto toraksPA subyek normal dan 103 CT scan  toraks subyek terpilih. Pada pemeriksaan toraks PA didapatkan rerata VPW 48,0±5,5mm, rerata VPCR 40,3±4,6%, dan rerata VPTR 17,2±1,7%. Pada pemeriksaan topogram CTscan didapatkan rerata VPW 50,3±6,2mm, rerata VPTR 45±5,1%, dan rerata VPTR 19,8±2,5%. Rerata VPWpada CT scan toraks 50,4±6,1mm. Pengukuran di foto toraks AP 10% lebih besar dibandingkan pada fototoraks PA dan pengukuranVPW di foto toraks terbukti memiliki akurasi  tinggi. Kata kunci: fototoraks, vascular pedicle width, vascular pedicle-cardiac ratio, vascular pedicle-thoracic ratio, hipervolemia.   The Mean Value of Vascular Pedicle Width, Vascular Pedicle-Cardiac Ratio,Vascular Pedicle-Thoracic Ratio of Normal Indonesian Adult Study In dr. Cipto Mangunkusomo Hospital Abstract Vascular pedicle width (VPW is the distance, from a perpendicular line at the takeoff point of the left subclavian artery off the aorta to the point at which the superior vena cava. Measurement of VPW on chestx-ray is relatively non-invasive, fast and easy technique as  hypervolemia predictor. The purpose of thisstudy is to know the mean VPW value of normal

  19. Pulse-width modulation for small heat pump installations - Phase 4; Pulsbreitenmodulation fuer Kleinwaermepumpenanlagen. Phase 4: Erweiterung der PBM-Regler fuer Kombianlagen

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, M.; Shafai, E. [Eidgenoessische Technische Hochschule (ETH), Institut fuer Mess- und Regeltechnik, Zuerich (Switzerland); Gabathuler, H.R.; Mayer, H. [Gabathuler AG, Beratende Ingenieure, Diessenhofen (Switzerland)

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of the fourth phase of a project that investigated three types of pulse-width modulation (PWM) controllers that were developed during its first two phases. A third phase monitored the controllers when used in a simulated environment and for a real-life heat pump. The report discusses the fourth phase of the project, in which the controller was further developed and tested using the building emulation developed in the third phase. The functioning of the self-regulating controller and its use of meteorological data is described and the savings to be made in heating costs are discussed.

  20. Electrical system for pulse-width modulated control of a power inverter using phase-shifted carrier signals and related operating methods

    Science.gov (United States)

    Welchko, Brian A [Torrance, CA

    2012-02-14

    Systems and methods are provided for pulse-width modulated control of power inverter using phase-shifted carrier signals. An electrical system comprises an energy source and a motor. The motor has a first set of windings and a second set of windings, which are electrically isolated from each other. An inverter module is coupled between the energy source and the motor and comprises a first set of phase legs coupled to the first set of windings and a second set of phase legs coupled to the second set of windings. A controller is coupled to the inverter module and is configured to achieve a desired power flow between the energy source and the motor by modulating the first set of phase legs using a first carrier signal and modulating the second set of phase legs using a second carrier signal. The second carrier signal is phase-shifted relative to the first carrier signal.

  1. High-speed three-dimensional shape measurement for dynamic scenes using bi-frequency tripolar pulse-width-modulation fringe projection

    Science.gov (United States)

    Zuo, Chao; Chen, Qian; Gu, Guohua; Feng, Shijie; Feng, Fangxiaoyu; Li, Rubin; Shen, Guochen

    2013-08-01

    This paper introduces a high-speed three-dimensional (3-D) shape measurement technique for dynamic scenes by using bi-frequency tripolar pulse-width-modulation (TPWM) fringe projection. Two wrapped phase maps with different wavelengths can be obtained simultaneously by our bi-frequency phase-shifting algorithm. Then the two phase maps are unwrapped using a simple look-up-table based number-theoretical approach. To guarantee the robustness of phase unwrapping as well as the high sinusoidality of projected patterns, TPWM technique is employed to generate ideal fringe patterns with slight defocus. We detailed our technique, including its principle, pattern design, and system setup. Several experiments on dynamic scenes were performed, verifying that our method can achieve a speed of 1250 frames per second for fast, dense, and accurate 3-D measurements.

  2. Analysis and Speed Ripple Mitigation of a Space Vector Pulse Width Modulation-Based Permanent Magnet Synchronous Motor with a Particle Swarm Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Xing Liu

    2016-11-01

    Full Text Available A method is proposed for reducing speed ripple of permanent magnet synchronous motors (PMSMs controlled by space vector pulse width modulation (SVPWM. A flux graph and mathematics are used to analyze the speed ripple characteristics of the PMSM. Analysis indicates that the 6P (P refers to pole pairs of the PMSM time harmonic of rotor mechanical speed is the main harmonic component in the SVPWM control PMSM system. To reduce PMSM speed ripple, harmonics are superposed on a SVPWM reference signal. A particle swarm optimization (PSO algorithm is proposed to determine the optimal phase and multiplier coefficient of the superposed harmonics. The results of a Fourier decomposition and an optimized simulation model verified the accuracy of the analysis as well as the effectiveness of the speed ripple reduction methods, respectively.

  3. Energy scaling of the "heartbeat" pulse width of GRS 1915+105, IGR J17091-3624, and MXB 1730-335 from Rossi-XTE observations

    Science.gov (United States)

    Maselli, A.; Capitanio, F.; Feroci, M.; Massa, F.; Massaro, E.; Mineo, T.

    2018-04-01

    We investigate some key aspects of the "heartbeat" variability consisting of series of bursts with a slow rise and a fast decay, thus far detected only in GRS 1915+105, IGR J17091-3624, and MXB 1730-335. A previous analysis based on BeppoSAX data of GRS 1915+105 revealed a hard-X delay (HXD), that is a lag of the burst rise at higher energies with respect to lower ones; this leads to narrower pulse widths, w, at higher energies. We here use some light curves of Rossi-XTE observations of GRS 1915+105 for a deeper analysis of this effect and search for its presence in those extracted from some IGR J17091-3624 and MXB 1730-335 observations performed with the same satellite. Our results show that, at variance with GRS 1915+105, no HXD is evident in the light curves of MXB 1730-335 and only a marginal HXD may be argued for IGR J17091-3624. For GRS 1915+105 we find a decreasing trend of the pulse width with energy following a power law w = A ṡ E-s with an index s ≈ 0.8. Furthermore, we confirm the increase of the HXD with the recurrence time Trec of the bursts in each series that was already found in previous works using BeppoSAX data. Based on a spectral analysis of these three sources we conclude that the differences highlighted in the properties of the "heartbeat" variability are probably related to the different accreting compact object and the eventual presence of a corona in these binary interacting systems.

  4. Flow Cytometry Pulse Width Data Enables Rapid and Sensitive Estimation of Biomass Dry Weight in the Microalgae Chlamydomonas reinhardtii and Chlorella vulgaris

    Science.gov (United States)

    Chioccioli, Maurizio; Hankamer, Ben; Ross, Ian L.

    2014-01-01

    Dry weight biomass is an important parameter in algaculture. Direct measurement requires weighing milligram quantities of dried biomass, which is problematic for small volume systems containing few cells, such as laboratory studies and high throughput assays in microwell plates. In these cases indirect methods must be used, inducing measurement artefacts which vary in severity with the cell type and conditions employed. Here, we utilise flow cytometry pulse width data for the estimation of cell density and biomass, using Chlorella vulgaris and Chlamydomonas reinhardtii as model algae and compare it to optical density methods. Measurement of cell concentration by flow cytometry was shown to be more sensitive than optical density at 750 nm (OD750) for monitoring culture growth. However, neither cell concentration nor optical density correlates well to biomass when growth conditions vary. Compared to the growth of C. vulgaris in TAP (tris-acetate-phosphate) medium, cells grown in TAP + glucose displayed a slowed cell division rate and a 2-fold increased dry biomass accumulation compared to growth without glucose. This was accompanied by increased cellular volume. Laser scattering characteristics during flow cytometry were used to estimate cell diameters and it was shown that an empirical but nonlinear relationship could be shown between flow cytometric pulse width and dry weight biomass per cell. This relationship could be linearised by the use of hypertonic conditions (1 M NaCl) to dehydrate the cells, as shown by density gradient centrifugation. Flow cytometry for biomass estimation is easy to perform, sensitive and offers more comprehensive information than optical density measurements. In addition, periodic flow cytometry measurements can be used to calibrate OD750 measurements for both convenience and accuracy. This approach is particularly useful for small samples and where cellular characteristics, especially cell size, are expected to vary during growth. PMID

  5. Prospective study of removing solar lentigines in Asians using a novel dual-wavelength and dual-pulse width picosecond laser.

    Science.gov (United States)

    Negishi, Kei; Akita, Hirotaka; Matsunaga, Yukiko

    2018-04-02

    Quality-switched (QS) lasers are known to be an effective treatment for removing solar lentigines, however, high incidence of post-inflammatory hyperpigmentation (PIH) is a concern in darker skin types. The objective of this study was to evaluate the efficacy and safety of a dual-wavelength and dual-pulse width picosecond Nd:YAG laser for removing solar lentigines in Asians. This was a prospective, IRB-approved study. Twenty cases with solar lentigines on the face were enrolled for treatment and evaluated at 1- and 3-month after the final treatment. Results were assessed by blinded evaluators using a 5-grade percentage improvement scale and Melanin index (MI) measured by a reflectance spectrophotometer. A patient self-assessment questionnaire was also administered using a 5-grade improvement scale. Additional treatment was performed if the improvement was less than 75% or the lentigo partially remained after 4 weeks. Histological evaluation was performed to compare the differences between the current picosecond laser and a QS Nd:YAG laser 532-nm using light and electron microscopy. Forty-three lesions in 20 females, skin type III or IV, age 53.7 ± 9.75 were treated and evaluated. The laser setting was: 532-nm, 750 picoseconds, average fluence of 0.35 ± 0.06 J/cm [2] using a spot size of 3 or 4 mm. Forty lesions (93.02%) achieved over 75% clearance with a single treatment and the other three lesions (6.98%) needed two treatments. PIH occurred only in 4.65% of lesions. The average score of the blinded evaluators' assessment was 4.77 and 4.58 on a 5-grade percentage improvement scale. The patients' self-assessment rating was 4.76 and 4.67 on a 5-grade scale at 1- and 3-month follow-up, respectively. The improvement rate of relative MI (MI in the lesion minus that of the normal area) was 77.60 ± 36.27% and 76.93 ± 20.95% at 1-and 3-month follow-up. Histology showed vacuolar formation by both lasers in the epidermis that were different sizes

  6. Production and correlation of reactive oxygen and nitrogen species in gas- and liquid-phase generated by helium plasma jets under different pulse widths

    Science.gov (United States)

    Liu, Zhijie; Zhou, Chunxi; Liu, Dingxin; Xu, Dehui; Xia, Wenjie; Cui, Qingjie; Wang, Bingchuan; Kong, Michael G.

    2018-01-01

    In this paper, we present the effects of the pulse width (PW) on the plasma jet's discharge characteristics, particularly focusing on the production and correlation of the reactive oxygen and nitrogen species (RONS) in gas- and liquid-phase. It is found that the length of plasma jet plume first increases before the PW of 10 μs, then gradually decreases and finally almost remains unchanged beyond 150 μs. The plasma bullet disappears after the falling edge of the voltage pulse at low PW, while it terminates far ahead of the falling edge of voltage pulse at high PW. This is mainly attributed to accumulation of space charges that lead to weakening of the reduced electric field with an increase of PW from low to high. More important, it is found that the excited reactive species, the positive and negative ions from plasma jet, and the concentrations of NO2- and NO3- in deionized water exposed to plasma jet also display the first increasing and then decreasing change trend with increase of PW, while the concentration of H2O2 in water almost displays the linearly increasing trend. This mainly results from the formation of the H3O+ and HO2-, as well as their ion water clusters that can produce more OH radicals to be converted into H2O2, while the NO2- and NO3- in gas phase can transport into water and exist most stably in water. The water cluster formation at gas-liquid interface is an important key process that can affect the chemical nature and dose of aqueous RONS in water; this is beneficial for understanding how the RONS are formed in liquid-phase.

  7. Glomerular epithelial foot processes in normal man and rats. Distribution of true width and its intra- and inter-individual variation.

    Science.gov (United States)

    Gundersen, H J; Seefeldt, T; Osterby, R

    1980-01-01

    The width of individual glomerular epithelial foot processes appears very different on electron micrographs. A method for obtainining distributions of the true width of foot processes from that of their apparent width on electron micrographs has been developed based on geometric probability theory pertaining to a specific geometric model. Analyses of foot process width in humans and rats show a remarkable interindividual invariance implying rigid control and therefore great biological significance of foot process width or a derivative thereof. The very low inter-individual variation of the true width, shown in the present paper, makes it possible to demonstrate slight changes in rather small groups of patients or experimental animals.

  8. Experimental investigations of pulse shape control in passively mode-locked fiber lasers with net-normal dispersion

    International Nuclear Information System (INIS)

    Wang, L R; Han, D D

    2013-01-01

    Pulse shape control in passively mode-locked fiber lasers with net-normal dispersion is investigated experimentally. Three kinds of pulses with different spectral and temporal shapes are observed, and their pulse-shaping mechanisms are discussed. After a polarization-resolved system external to the cavity, the maximum intensity differences of the two polarization components for the rectangular-spectrum (RS), Gaussian-spectrum (GS), and super-broadband (SB) pulses are measured as ∼20 dB, ∼15 dB, and ∼1 dB, respectively. It is suggested that the equivalent saturable absorption effect plays an increasingly important role from the RS to GS and then to SB pulses in the pulse-shaping processes, while the spectral filtering effect declines. This work could help in systematically understanding pulse formation and proposing guidelines for the realization of pulses with better performance in fiber lasers. (paper)

  9. Fabrication of porous anodic alumina using normal anodization and pulse anodization

    Science.gov (United States)

    Chin, I. K.; Yam, F. K.; Hassan, Z.

    2015-05-01

    This article reports on the fabrication of porous anodic alumina (PAA) by two-step anodizing the low purity commercial aluminum sheets at room temperature. Different variations of the second-step anodization were conducted: normal anodization (NA) with direct current potential difference; pulse anodization (PA) alternate between potential differences of 10 V and 0 V; hybrid pulse anodization (HPA) alternate between potential differences of 10 V and -2 V. The method influenced the film homogeneity of the PAA and the most homogeneous structure was obtained via PA. The morphological properties are further elucidated using measured current-transient profiles. The absent of current rise profile in PA indicates the anodization temperature and dissolution of the PAA structure were greatly reduced by alternating potential differences.

  10. Histopathology of normal skin and melanomas after nanosecond pulsed electric field treatment

    Science.gov (United States)

    Chen, Xinhua; Swanson, R. James; Kolb, Juergen F.; Nuccitelli, Richard; Schoenbach, Karl H.

    2011-01-01

    Nanosecond pulsed electric fields (nsPEFs) can affect the intracellular structures of cells in vitro. This study shows the direct effects of nsPEFs on tumor growth, tumor volume, and histological characteristics of normal skin and B16-F10 melanoma in SKH-1 mice. A melanoma model was set up by injecting B16-F10 into female SKH-1 mice. After a 100-pulse treatment with an nsPEF (40-kV/cm field strength; 300-ns duration; 30-ns rise time; 2-Hz repetition rate), tumor growth and histology were studied using transillumination, light microscopy with hematoxylin and eosin stain and transmission electron microscopy. Melanin and iron within the melanoma tumor were also detected with specific stains. After nsPEF treatment, tumor development was inhibited with decreased volumes post-nsPEF treatment compared with control tumors (Pelectric fields surrounding the needle electrodes. PMID:19730404

  11. Development of microheaters for gas sensor with an AT-Mega 8535 temperature controller using a PWM (pulse width modulation) method

    Science.gov (United States)

    Megayanti, Meti; Panatarani, Camellia; Joni, I. Made

    2016-03-01

    Microheater is the main component in gas sensor characterized by their sensitivity, selectivity, and time response of gas sensor which is depend on the microheater temperature stability. A Cu microheater was developed and utilized AT-Mega 8535 controller using a PWM (pulse width modulation) method. This control system is interfaced to the PC to observe the real time temperature response of the microheater. Three initial resistance (R0) variations of microheater were developed in an open loop control system. The power characteristic of designed microheater depends on the specified microheater initial resistance. The smaller R0, the less power required to reach a temperature setting value. The developed microheater was designed to reach a temperature setting value of 250°C having resistance 0.531 Ω for 1.979 Watt and 0.265 Ω for 1.072 Watt respectively. The results of the investigation on the control performances shows microheater-control system achieved operating temperature up to 250°C. The response of the temperature control shows smallest R0 resulted in a high stability with short settling time, short delay time and small ripple for temperature setting values higher than 150°C. The obtained error of microheater temperature with R0 = 0.265 is 8.596 %. It is concluded that the developed microheater can be utilized as a component of a gas sensor.

  12. Development of microheaters for gas sensor with an AT-Mega 8535 temperature controller using a PWM (pulse width modulation) method

    Energy Technology Data Exchange (ETDEWEB)

    Megayanti, Meti; Panatarani, Camellia; Joni, I. Made, E-mail: imadejoni@phys.unpad.ac.id [Instrumentation System and Functional Material Processing Laboratory, Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran Jalan Raya Bandung-Sumedang KM 21, Jatinangor 45363, West Java (Indonesia)

    2016-03-11

    Microheater is the main component in gas sensor characterized by their sensitivity, selectivity, and time response of gas sensor which is depend on the microheater temperature stability. A Cu microheater was developed and utilized AT-Mega 8535 controller using a PWM (pulse width modulation) method. This control system is interfaced to the PC to observe the real time temperature response of the microheater. Three initial resistance (R0) variations of microheater were developed in an open loop control system. The power characteristic of designed microheater depends on the specified microheater initial resistance. The smaller R0, the less power required to reach a temperature setting value. The developed microheater was designed to reach a temperature setting value of 250°C having resistance 0.531 Ω for 1.979 Watt and 0.265 Ω for 1.072 Watt respectively. The results of the investigation on the control performances shows microheater-control system achieved operating temperature up to 250°C. The response of the temperature control shows smallest R0 resulted in a high stability with short settling time, short delay time and small ripple for temperature setting values higher than 150°C. The obtained error of microheater temperature with R0 = 0.265 is 8.596 %. It is concluded that the developed microheater can be utilized as a component of a gas sensor.

  13. An adaptive neuro fuzzy inference system controlled space cector pulse width modulation based HVDC light transmission system under AC fault conditions

    Science.gov (United States)

    Ajay Kumar, M.; Srikanth, N. V.

    2014-03-01

    In HVDC Light transmission systems, converter control is one of the major fields of present day research works. In this paper, fuzzy logic controller is utilized for controlling both the converters of the space vector pulse width modulation (SVPWM) based HVDC Light transmission systems. Due to its complexity in the rule base formation, an intelligent controller known as adaptive neuro fuzzy inference system (ANFIS) controller is also introduced in this paper. The proposed ANFIS controller changes the PI gains automatically for different operating conditions. A hybrid learning method which combines and exploits the best features of both the back propagation algorithm and least square estimation method is used to train the 5-layer ANFIS controller. The performance of the proposed ANFIS controller is compared and validated with the fuzzy logic controller and also with the fixed gain conventional PI controller. The simulations are carried out in the MATLAB/SIMULINK environment. The results reveal that the proposed ANFIS controller is reducing power fluctuations at both the converters. It also improves the dynamic performance of the test power system effectively when tested for various ac fault conditions.

  14. Pulse-Width Modulation Pre Emphasis applied in a Wireline Transmitter, achieving 33dB Loss Compensation at 5-Gb/s in 0.13-μm CMOS

    NARCIS (Netherlands)

    Schrader, J.H.R.; Klumperink, Eric A.M.; Visschers, J.L.; Nauta, Bram

    2006-01-01

    Abstract—A transmitter pre-emphasis technique for copper cable equalization is presented that is based on pulse-width modulation (PWM). This technique is an alternative to the usual 2-tap symbol-spaced FIR (SSF) pre-emphasis. The technique uses timing resolution instead of amplitude resolution to

  15. The venous manifestations of pulse wave encephalopathy: windkessel dysfunction in normal aging and senile dementia

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, Grant A. [Locked Bag 1, Newcastle Region Mail Center, Department of Medical Imaging, John Hunter Hospital, Newcastle (Australia); Levi, Christopher R.; Wang, Yang; Lovett, Elizabeth C. [Hunter Medical Research Institute, Clinical Neurosciences Program, Newcastle (Australia); Schofield, Peter [James Fletcher Hospital, Neuropsychiatry Unit, Newcastle (Australia)

    2008-06-15

    Cerebral arterial, venous and cerebrospinal fluid (CSF) pulsations are closely coupled and this produces pulsation dampening or the windkessel effect. Normal pressure hydrocephalus is a manifestation of the breakdown of this windkessel effect with altered CSF and venous pulsations being noted. The aim of this study was to show that dysfunction of the windkessel mechanism is also a component of normal aging and senile dementia. The study group comprised 24 patients classified as either early senile dementia of Alzheimer's type (SDAT) or vascular dementia (VaD). The patients with dementia were compared with 12 age-matched non-cognitively impaired subjects, and 12 normal young individuals were compared with the normal aging group. MRI flow quantification was used to measure the nonpulsatile and pulsatile components of blood flow as well as the pulsation at the tentorial incisura. With normal aging blood flow decreased but arterial pulsations increased in volume by 49% (P = 0.003). The CSF vented via the tentorial incisura does not change significantly with age and therefore increased venous pulsation is necessary. In patients with VaD the arterial pulse volume was higher by 24% and the straight sinus pulsation was higher by 57% than in normal aging subjects (P = 0.05 and P = 0.03, respectively). In patients with SDAT the total venous pulsation volumes were similar to those in normal aging subjects but there was less basal sinus pulsation. Normal aging, SDAT and VaD are associated with alterations in venous pulsation due to a breakdown of the windkessel effect. (orig.)

  16. Level width broadening effect

    International Nuclear Information System (INIS)

    Zhang Jingshang

    2003-01-01

    In file-6 for double-differential cross sections, the level width broadening effect should be taken into account properly due to Heisenberg' uncertainty. Besides level width broadening effect, the energy resolution in the measurements is also needed in fitting measurement procedure. In general, the traditional normal Gaussian expansion is employed. However, to do so in this way the energy balance could not be held. For this reason, the deformed Gaussian expansion functions with exponential form for both the single energy point and continuous spectrum are introduced, with which the normalization and energy balance conditions could be held exactly in the analytical form. (author)

  17. [Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].

    Science.gov (United States)

    Hamela-Olkowska, Anita; Dangel, Joanna

    2009-08-01

    To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (page of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.

  18. A 12-bit spectroscopy analog-to-digital converter type SAA (Successive Approximation type with channel width Averaging) intended for multichannel pulse height analyzer SWAN-1 based on IBM PC/XT/AT

    International Nuclear Information System (INIS)

    Borsuk, S.; Kulka, Z.

    1989-12-01

    A 12-bit spectroscopy analog-to-digital converter (ADC) type SAA (Successive Approximation type with channel width Averaging) intended for multichannel pulse height analyzer SWAN-1 based on IBM PC/XT/AT has been described. Design principles, specifications and measurements of a fundamental SAA-2 converter version are reported. Finally, two next versions of the converter with introduced modifications are discussed. 6 refs., 7 figs. (author)

  19. Short-wavelength soft-x-ray laser pumped in double-pulse single-beam non-normal incidence

    International Nuclear Information System (INIS)

    Zimmer, D.; Ros, D.; Guilbaud, O.; Habib, J.; Kazamias, S.; Zielbauer, B.; Bagnoud, V.; Ecker, B.; Aurand, B.; Kuehl, T.; Hochhaus, D. C.; Neumayer, P.

    2010-01-01

    We demonstrated a 7.36 nm Ni-like samarium soft-x-ray laser, pumped by 36 J of a neodymium:glass chirped-pulse amplification laser. Double-pulse single-beam non-normal-incidence pumping was applied for efficient soft-x-ray laser generation. In this case, the applied technique included a single-optic focusing geometry for large beam diameters, a single-pass grating compressor, traveling-wave tuning capability, and an optimized high-energy laser double pulse. This scheme has the potential for even shorter-wavelength soft-x-ray laser pumping.

  20. On the trade-off between mainlobe width and peak sidelobe level of mismatched pulse compression filters for linear chirp waveforms

    CSIR Research Space (South Africa)

    Cilliers, Jacques E

    2009-09-01

    Full Text Available that constant, extremely low sidelobe levels better than 60 dB can be achieved for minimal mismatch loss but with some broadening of the compression peak. This paper investigates the tradeoff between the sidelobe level and the mainlobe width for mismatched...

  1. Narrow Q-switching pulse width and low mode-locking repetition rate Q-switched mode locking with a new coupled laser cavity

    International Nuclear Information System (INIS)

    Peng, J Y; Zheng, Y; Shen, J P; Shi, Y X

    2013-01-01

    An original diode-pumped Q-switched and mode-locked solid state Nd:GdVO 4 laser is demonstrated. The laser operates with double saturable absorbers and a new coupled laser cavity. The Q-switching envelope width is compressed to be about 15 ns and the mode-locking repetition rate is as low as 90 MHz. (paper)

  2. Corpus luteum blood flow in normal and abnormal early pregnancy: evaluation and analysis with transvaginal color and pulsed doppler sonography

    International Nuclear Information System (INIS)

    Tang Xiaoyi; Lin Meifang; Zheng Meirong; Liang Xiaoxian; Liu Jianfeng

    2005-01-01

    Objective: Detecting and assessment the corpus luteum blood flow in normal and abnormal early pregnancy. Methods: Using transvaginal color and pulse Doppler sonography, we detected 215 pregnant women including 150 normal intrauterine pregnancies, 25 abortion, 29 ectopic pregnancies, and then recorded corpus luteum blood flow feature and the blood flow indexes (Vmax, RI and PI). Results: 1) Corpus luteum was successfully identified in 148 cases out of 150 of normal early pregnancies, 25 cases out of 26 of threatened abortion; 22 cases out of 29 of ectopic pregnancy. 2) Three groups shared the same feature of Color Doppler imaging: a circumferential rim around the entire corpus luteum. 3) The flow index revealed mean PVS, RI and PI had no statistical difference in normal and abnormal early pregnancy; The mean PVS was lower in ectopic pregnancy than in normal pregnancy (P<0.05), while PI and PR had no characteristic in ectopic pregnancy group compared with the indexes obtained in normal pregnancy group. Conclusion: The corpus luteum can be precisely identified in most pregnancy using transvaginal color Doppler and manifests a characterized rim Doppler imaging. PVS may help in differentiating the ectopic pregnancy from normal early pregnancy. (authors)

  3. Ultrasound evaluation of normal and abnormal fetuses: comparison of conventional, tissue harmonic, and pulse- inversion harmonic imaging techniques

    International Nuclear Information System (INIS)

    Ryu, Jeong Ah; Kim, Bohyun; Kim, Sooah; Yang, Soon Ha; Choi, Moon Hae; Ahn, Hyeong Sik

    2003-01-01

    To determine the usefulness of tissue harmonic imaging (THI) and pulse-inversion harmonic imaging (PIHI) in the evaluation of normal and abnormal fetuses. Forty-one pregnant women who bore a total of 31 normal and ten abnormal fetuses underwent conventional ultrasonography (CUS), and then THI and PIHI. US images of six organ systems, namely the brain, spine, heart, abdomen, extremities and face were compared between the three techniques in terms of overall conspicuity and the definition of borders and internal structures. For the brain, heart, abdomen and face, overall conspicuity at THI and PIHI was significantly better than at CUS (p < 0.05). There was, though, no significant difference between THI and PIHI. Affected organs in abnormal fetuses were more clearly depicted at THI and PIHI than at CUS. Both THI and PIHI appear to be superior to CUS for the evaluation of normal or abnormal structures, particularly the brain, heart, abdomen and face

  4. Interpretation of photovoltaic pulses in normal YBa2Cu3O7

    International Nuclear Information System (INIS)

    Scott, J.F.

    1990-01-01

    200 mV photovoltaic voltage pulses reported [C. L. Chang, A. Kleinhammes, W. G. Moulton, and L. R. Testardi Phys. Rev. B (in press)] for YBa 2 Cu 3 O 7 illuminated with 2--30 mJ/cm 2 at 532 nm are interpreted in terms of the complete theory of photovoltaic responses, including off-diagonal terms not recognized in the original theory. The resulting predictions are in reasonable quantitative agreement with experiment

  5. A comparison between the pathophysiology of multiple sclerosis and normal pressure hydrocephalus: is pulse wave encephalopathy a component of MS?

    Science.gov (United States)

    Bateman, Grant A; Lechner-Scott, Jeannette; Lea, Rodney A

    2016-09-22

    It has been suggested there is a chronic neurodegenerative disorder, underlying the pathophysiology of multiple sclerosis (MS), which is distinct from the more obvious immune-mediated attack on the white matter. Limited data exists indicating there is an alteration in pulse wave propagation within the craniospinal cavity in MS, similar to the findings in normal pressure hydrocephalus (NPH). It is hypothesized MS may harbor pulse wave encephalopathy. The purpose of this study is to compare blood flow and pulse wave measurements in MS patients with a cohort of NPH patients and control subjects, to test this hypothesis. Twenty patients with MS underwent magnetic resonance (MR) flow quantification techniques. Mean blood flow and stroke volume were measured in the arterial inflow and venous out flow from the sagittal (SSS) and straight sinus (ST). The arteriovenous delay (AVD) was defined. The results were compared with both age-matched controls and NPH patients. In MS there was a 35 % reduction in arteriovenous delay and a 5 % reduction in the percentage of the arterial inflow returning via the sagittal sinus compared to age matched controls. There was an alteration in pulse wave propagation, with a 26 % increase in arterial stroke volume but 30 % reduction in SSS and ST stroke volume. The AVD and blood flow changes were in the same direction to those of NPH patients. There are blood flow and pulsation propagation changes in MS patients which are similar to those of NPH patients. The findings would be consistent with an underlying pulse wave encephalopathy component in MS.

  6. Magnetic resonance imaging of the normal pituitary gland using ultrashort TE (UTE) pulse sequences (REV 1.0)

    International Nuclear Information System (INIS)

    Portman, Olivia; Flemming, Stephen; Cox, Jeremy P.D.; Johnston, Desmond G.; Bydder, Graeme M.

    2008-01-01

    The purpose of this study was to examine the normal pituitary gland in male subjects with ultrashort echo time (TE) pulse sequences, describe its appearance and measure its signal intensity before and after contrast enhancement. Eleven male volunteers (mean age 57.1 years; range 36-81 years) were examined with a fat-suppressed ultrashort TE (= 0.08 ms) pulse sequence. The studies were repeated after the administration of intravenous gadodiamide. The MR scans were examined for gland morphology and signal intensity before and after enhancement. Endocrinological evaluation included baseline pituitary function tests and a glucagon stimulatory test to assess pituitary cortisol and growth hormone reserve. High signal intensity was observed in the anterior pituitary relative to the brain in nine of the 11 subjects. These regions involved the whole of the anterior pituitary in three subjects, were localised to one side in two examples and were seen inferiorly in three subjects. Signal intensities relative to the brain increased with age, with a peak around the sixth or seventh decade and decreasing thereafter. Overall, the pituitary function tests were considered to be within normal limits and did not correlate with pituitary gland signal intensity. The anterior pituitary shows increased signal intensity in normal subjects when examined with T 1 -weighted ultrashort TE pulse sequences. The cause of this increased intensity is unknown, but fibrosis and iron deposition are possible candidates. The variation in signal intensity with age followed the temporal pattern of iron content observed at post mortem. No relationship with endocrine status was observed. (orig.)

  7. Magnetic resonance imaging of the normal pituitary gland using ultrashort TE (UTE) pulse sequences (REV 1.0)

    Energy Technology Data Exchange (ETDEWEB)

    Portman, Olivia; Flemming, Stephen; Cox, Jeremy P.D.; Johnston, Desmond G. [Imperial College Faculty of Medicine, St Mary' s Hospital, Endocrinology and Metabolic Medicine, London (United Kingdom); Bydder, Graeme M. [University of California, San Diego, Department of Radiology, San Diego, CA (United States)

    2008-03-15

    The purpose of this study was to examine the normal pituitary gland in male subjects with ultrashort echo time (TE) pulse sequences, describe its appearance and measure its signal intensity before and after contrast enhancement. Eleven male volunteers (mean age 57.1 years; range 36-81 years) were examined with a fat-suppressed ultrashort TE (= 0.08 ms) pulse sequence. The studies were repeated after the administration of intravenous gadodiamide. The MR scans were examined for gland morphology and signal intensity before and after enhancement. Endocrinological evaluation included baseline pituitary function tests and a glucagon stimulatory test to assess pituitary cortisol and growth hormone reserve. High signal intensity was observed in the anterior pituitary relative to the brain in nine of the 11 subjects. These regions involved the whole of the anterior pituitary in three subjects, were localised to one side in two examples and were seen inferiorly in three subjects. Signal intensities relative to the brain increased with age, with a peak around the sixth or seventh decade and decreasing thereafter. Overall, the pituitary function tests were considered to be within normal limits and did not correlate with pituitary gland signal intensity. The anterior pituitary shows increased signal intensity in normal subjects when examined with T{sub 1}-weighted ultrashort TE pulse sequences. The cause of this increased intensity is unknown, but fibrosis and iron deposition are possible candidates. The variation in signal intensity with age followed the temporal pattern of iron content observed at post mortem. No relationship with endocrine status was observed. (orig.)

  8. The pulse-driven AC Josephson voltage normal; Das pulsgetriebene AC-Josephson-Spannungsnormal

    Energy Technology Data Exchange (ETDEWEB)

    Kieler, Oliver [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Arbeitsgruppe 2.43 ' ' Josephson-Schaltungen' '

    2016-09-15

    In this contribution quantum precise alternating-voltage sources are presented, which make the generation of arbitrary wave forms with highest spectral purity with a high bandwidth from DC up to the MHz range possible. Heartpiece of these Josephson voltage normals is a serial circuit of many thousand Josephson contacts, which make by irradiation with high-frequency radiation (microwaves) the generation of highly precise voltage values possible. Thereby in the current-voltage characteristics stages of constant voltage, so called Shapiro stages, occur. Illustratively these stages can be described by the transfer of a certain number of flux quanta through the Josephson contacts.

  9. Histologic evaluation of skin damage after overlapping and nonoverlapping flashlamp pumped pulsed dye laser pulses: A study on normal human skin as a model for port wine stains

    NARCIS (Netherlands)

    Koster, P. H.; van der Horst, C. M.; van Gemert, M. J.; van der Wal, A. C.

    2001-01-01

    BACKGROUND AND OBJECTIVE: In the treatment of port wine stains (PWS) with the flashlamp pumped pulsed dye laser (FPPDL), no consensus exists about overlapping of pulses. The advantage of overlapping pulses is homogeneous lightening of the PWS; the risk is redundant tissue damage. The aim of this

  10. MR of normal pancreas : comparison of five pulse sequences and enhancing patterns on dynamic imaging

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Kim, Tae Kyoung; Hong, Sung Hwan; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To compare T1-weighted FLASH and turbo spin echo (SE) T2-weighted sequences with conventional T1- and T2-weighted sequences in imaging normal pancreas and to describe the enhancing patterns on dynamic MR imging. Forty-four patients with presumed hepatic hemangiomas were studied at 1.0T or 1.5T by using conventional SE sequences (T1-weighted, T2-weighted, and heavily T2-weighted), turbo-SE T2-weighted sequences, and breath-hold T1-weighted FLASH sequences acquired before, immediately on, and at 1, 2, 3, and 5 or 10 minutes after injection of a bolus of gadopentetate dimeglumine. No patients had either a history or its clinical features of pancreatic disease. Images were quantitatively analyzed for signal-difference-to noise ratios (SD/Ns) between the pancreas and peripancreatic fat. Percentage enhancement of the pancreas was measured on each dynamic MR image. Conspicuity of the pancreatic border was qualitatively evaluated according to a consensus, reached by three radiologists. Turbo-SE T2-weighted images had a significantly higher SD/N ratio (p<0.001) and better conspicuity of the pancreatic border (p<0.001) than SE T2- and heavily T2-weighted images;T1-weighted SE images had a significantly higher SD/N ratio than T1-weighted FLASH images (p<0.001), but there was no significant difference between tham in qualitative analysis (p=0.346). Percentage enhancement immediately on and at 1, 2, 3, 5, and 10 minutes after administration of contrast material was 39.9%, 44.5%, 42.9%, 40.8%, 36.3%, 29.9%, respectively, with peak enhancement at 1 minute. In MR imaging of normal pancreas, turbo-SE T2-weighted imaging is superior to SE T2- and heavily T2- weighted imaging, and SE T1-weighted imaging is superior to T1-weighted FLASH imaging. On serial gadolinium-enhanced FLASH imaging, normal pancreas shows peak enhancement at 1 minute

  11. Responses of human normal osteoblast cells and osteoblast-like cell line, MG-63 cells, to pulse electromagnetic field (PEMF

    Directory of Open Access Journals (Sweden)

    Suttatip Kamolmatyakul

    2008-01-01

    Full Text Available The objective of this in vitro study is to investigate the effect of pulsed electromagnetic field (PEMF on cellular proliferation and osteocalcin production of osteoblast-like cell line, MG-63 cells, and human normal osteoblast cells (NHOC obtained from surgical bone specimens. The cells were placed in 24-well culture plates in the amount of 3x104 cell/wells with 2 ml αMEM media supplemented with 10% FBS. The experimental plates were placed between a pair of Helmoltz coils powered by a pulse generator (PEMF, 50 Hz, 1.5 mV/cm in the upper compartment of a dual incubator (Forma. The control plates were placed in the lower compartment of the incubator without Helmotz coils. After three days, the cell proliferation was measured by the method modified from Mossman (J. Immunol Methods 1983; 65: 55-63. Other sets of plates were used for osteocalcin production assessment. Media from these sets were collected after 6 days and assessed for osteocalcin production using ELISA kits. The data were analyzed using a one-way analysis of variance (ANOVA. The results showed that MG-63 cells from the experimental group proliferated significantly more than those from the control group (20% increase, p<0.05. No significant difference in osteocalcin production was detected between the two groups. On the other hand, NHOC from the experimental group produced larger amount of osteocalcin (25% increase, p<0.05 and proliferated significantly more than those from the control group (100% increase, p<0.05. In conclusion, PEMF effect on osteoblasts might depend on their cell type of origin. For osteoblast-like cell line, MG-63 cells, PEMF increased proliferation rate but not osteocalcin production of the cells. However, PEMF stimulation effect on human normal osteoblast cells was most likely associated with enhancement of both osteocalcin production and cell proliferation.

  12. Normal Reflection Characteristics of One-Dimensional Unsteady Flow Shock Waves on Rigid Walls from Pulse Discharge in Water

    Directory of Open Access Journals (Sweden)

    Dong Yan

    2017-01-01

    Full Text Available Strong shock waves can be generated by pulse discharge in water, and the characteristics due to the shock wave normal reflection from rigid walls have important significance to many fields, such as industrial production and defense construction. This paper investigates the effects of hydrostatic pressures and perturbation of wave source (i.e., charging voltage on normal reflection of one-dimensional unsteady flow shock waves. Basic properties of the incidence and reflection waves were analyzed theoretically and experimentally to identify the reflection mechanisms and hence the influencing factors and characteristics. The results indicated that increased perturbation (i.e., charging voltage leads to increased peak pressure and velocity of the reflected shock wave, whereas increased hydrostatic pressure obviously inhibited superposition of the reflection waves close to the rigid wall. The perturbation of wave source influence on the reflected wave was much lower than that on the incident wave, while the hydrostatic pressure obviously affected both incident and reflection waves. The reflection wave from the rigid wall in water exhibited the characteristics of a weak shock wave, and with increased hydrostatic pressure, these weak shock wave characteristics became more obvious.

  13. Normal values of aortic dimensions, distensibility, and pulse wave velocity in children and young adults: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Voges Inga

    2012-11-01

    Full Text Available Abstract Background Aortic enlargement and impaired bioelasticity are of interest in several cardiac and non-cardiac diseases as they can lead to cardiovascular complications. Cardiovascular magnetic resonance (CMR is increasingly accepted as a noninvasive tool in cardiovascular evaluation. Assessment of aortic anatomy and bioelasticity, namely aortic distensibility and pulse wave velocity (PWV, by CMR is accurate and reproducible and could help to identify anatomical and bioelastic abnormalities of the aorta. However, normal CMR values for healthy children and young adults are lacking. Methods Seventy-one heart-healthy subjects (age 16.4 ± 7.6 years, range 2.3 - 28.3 years were examined using a 3.0 Tesla CMR scanner. Aortic cross-sectional areas and aortic distensibility were measured at four positions of the ascending and descending thoracic aorta. PWV was assessed from aortic blood flow velocity measurements in a aortic segment between the ascending aorta and the proximal descending aorta. The Lambda-Mu-Sigma (LMS method was used to obtain percentile curves for aortic cross-sectional areas, aortic distensibility and PWV according to age. Results Aortic areas, PWV and aortic distensibility (aortic cross-sectional areas: r = 0.8 to 0.9, p  Conclusions This study provides percentile curves for cross-sectional areas, distensibility and pulse wave velocity of the thoracic aorta in children and young adolescents between their 3rd and 29th year of life. These data may serve as a reference for the detection of pathological changes of the aorta in cardiovascular disease.

  14. Effect of physical activity on pulse wave velocity in elderly subjects with normal glucose, prediabetes or Type 2 Diabetes.

    Science.gov (United States)

    Metsämarttila, Erja; Rodilla, Enrique; Jokelainen, Jari; Herrala, Sauli; Leppäluoto, Juhani; Keinänen-Kiukaanniemi, Sirkka; Herzig, Karl-Heinz

    2018-05-23

    Carotid-femoral pulse wave velocity ((cf)PWV) is a measure of arterial stiffness, predicting cardiovascular disease. We hypothesized that the amount of physical activity (PA) is correlated with reduced arterial stiffness in Type 2 diabetic (T2D) subjects. 570 subjects from the 1945 Oulu birth cohort were included in the analysis. (cf)PWV was determined by a non-invasive applanation tonometry. Oral glucose tolerance test was performed and LDL and HDL cholesterol analyzed. PA was registered daily with a wrist-worn acceleration meter for two weeks. (cf)PWV values in subjects with impaired glucose metabolism (IGM) and T2D were higher than in normal glycemic subjects (P < 0.001). PA, fasting and 2 h glucose and HbA1c correlated significantly with (cf)PWV, but HDL or LDL cholesterol did not. The 2 h glucose, heart rate and alcohol consumption in T2D subjects had independent effects on (cf)PWV in multiple regression analysis. T2D and IGM were significantly associated to (cf)PWV. Interestingly, lipids did not have an additional effect on (cf)PWV. Subjects walking more than 10 000 steps/day had 0.2 m/s lower (cf)PWV than those walking less than 6000 steps/day. Presence of T2D, elevated heart rate and alcohol consumption in males were associated with increased aortic stiffening in elderly subjects.

  15. Compliance of the normal-sized aorta in adolescents with Marfan syndrome: comparison of MR measurements of aortic distensibility and pulse wave velocity

    International Nuclear Information System (INIS)

    Eichhorn, J.G.; Ruediger, H.J.; Gorenflo, M.; Khalil, M.; Ulmer, H.; Krissak, R.; Kauczor, H.U.; Ley, S.; Universitaetsklinik Heidelberg; Arnold, R.; Universitaetskinderklinik Freiburg; Boese, J.; Siemens AG, Medical Solutions, Forchheim; Krug, R.; Fink, C.

    2007-01-01

    Purpose: To compare the aortic compliance of the normal-sized aorta of adolescents with Marfan syndrome and healthy controls using MR measurements of the aortic distensibility and pulse wave velocity. Materials and Methods: Fourteen patients (median age: 15 [9-21] years) and 11 healthy subjects (23 [12-32] years) were examined at 1.5 T. The MR protocol included 2D steady-state free precession (SSFP)-CINE MRI of the aortic distensibility and PC-MRI of the pulse wave velocity. All measurements were positioned perpendicular to the descending aorta at the level of the diaphragm for assessing the changes in the aortic cross-sectional areas and additionally above and below this plane for assessing the pulse wave velocity. In addition contrast-enhanced 3D-MR angiography was performed in adolescents with Marfan syndrome to exclude morphologic changes and to prove normal-sized aorta. Results: Compared with control subjects, adolescents with Marfan syndrome had significantly decreased distensibility and significantly increased pulse wave velocity (χ 2 -test, p = 0.0002) using an age-related non-linear regression analysis. The related aortic compliance was significantly decreased (χ 2 -test, p = 0.0002). There was a good correlation between the two methods (r = 0.86). A low intraobserver variability was found for both methods (≤ 2 %). (orig.)

  16. Hair removal in hirsute women with normal testosterone levels: a randomized controlled trial of long-pulsed diode laser vs. intense pulsed light

    DEFF Research Database (Denmark)

    Haak, C S; Jensen, Pernille Nymann; Pedersen, A T

    2010-01-01

    Hirsutism is a common disorder in women of reproductive age, and androgen disturbances may aggravate the condition. Limited evidence exists regarding efficacy of hair removal in this specific population and no data are available for patients with verified normal testosterone levels.......Hirsutism is a common disorder in women of reproductive age, and androgen disturbances may aggravate the condition. Limited evidence exists regarding efficacy of hair removal in this specific population and no data are available for patients with verified normal testosterone levels....

  17. Stokes line width

    International Nuclear Information System (INIS)

    Nikiskov, A.I.; Ritus, V.I.

    1993-01-01

    The concept of Stokes line width is introduced for the asymptotic expansions of functions near an essential singularity. Explicit expressions are found for functions (switching functions) that switch on the exponentially small terms for the Dawson integral, Airy function, and the gamma function. A different, more natural representation of a function, not associated with expansion in an asymptotic series, in the form of dominant and recessive terms is obtained by a special division of the contour integral which represents the function into contributions of higher and lower saddle points. This division leads to a narrower, natural Stokes line width and a switching function of an argument that depends on the topology of the lines of steepest descent from the saddle point

  18. Hair removal in hirsute women with normal testosterone levels: a randomized controlled trial of long-pulsed diode laser vs. intense pulsed light

    DEFF Research Database (Denmark)

    Haak, C S; Jensen, Pernille Nymann; Pedersen, A T

    2010-01-01

    Hirsutism is a common disorder in women of reproductive age, and androgen disturbances may aggravate the condition. Limited evidence exists regarding efficacy of hair removal in this specific population and no data are available for patients with verified normal testosterone levels....

  19. DNA double-strand breaks measured by pulsed-field gel electrophoresis in irradiated lymphocytes from normal humans and those with Alzheimer's disease

    International Nuclear Information System (INIS)

    Tobi, S.E.; Itzhaki, R.F.

    1993-01-01

    The authors previously found that radiation-induced chromosome aberrations (dicentrics) are more numerous in lymphocytes from Alzheimer's disease (AD) patients than in those from age-matched normal individuals (Tobi et al. 1990). They have examined double-strand breaks (dsb) produced by g amma - irradiation in the DNA of AD and normal lymphocytes by using pulsed-field gel electrophoresis. The percentage of DNA migrating into the gels is an indirect measure of the number of dsb; DNA content of sequential slices of the gel was assayed by direct fluorometry and the percentage migrating was dose dependent. Results show that the level of damage is similar in AD and normal lymphocytes and preliminary assays of the rate of repair suggest that the half-time is also similar, the value being > 1 h. The latter is consistent with the known rate of rejoining of chromosome fragments in interphase lymphocytes (Pantelias and Maillie 1985). (Author)

  20. Numerical simulation of extremely chirped pulse formation with an optical fiber

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Tamitake; Nishimura, Akihiko; Tei, Kazuyoku; Matoba, Tohru; Takuma, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Yamashita, Mikio; Morita, Ryuji

    1998-03-01

    A nonlinear propagation code which used a symmetric split-step Fourier method as an algorithm was improved to simulate a propagation behavior of extremely chirped pulse in a long fiber. The performances of pulse propagation in noble gases cored hollow fibers and a pulse stretcher using a nonlinear and normal silicate fibers have been simulated by the code. The calculation results in the case of the hollow fiber are consistent with their experimental results. We estimated that this pulse stretcher could give a extremely chirped pulse whose spectral width was 84.2 nm and temporal duration was 1.5 ns. (author)

  1. Normal pedal pulses in a popliteal artery thrombosis after a trampoline-associated knee dislocation: a case report.

    Science.gov (United States)

    Harb, Z; Harb, A; Kammoona, Ishan; Huber, C

    2011-04-01

    In lower extremity trauma, it is routine to check the neurovascular status of the affected limb. Failure to recognise a vascular injury can have catastrophic consequences for the patient. The frequent observation of the distal pulses at regular intervals after a traumatic knee dislocation is absolutely mandatory for the early recognition and management of popliteal artery thrombosis. A limb-threatening complication of popliteal artery thrombosis occurring in association with a palpable dorsalis pedis pulse after a trampoline-related knee dislocation is reported here to emphasise some important teaching points. These lessons are a learning tool to help in the early recognition of the potential complications associated with such injuries and thus minimise their occurrence.

  2. Correlation of pulse wave velocity with left ventricular mass in patients with hypertension once blood pressure has been normalized

    Directory of Open Access Journals (Sweden)

    Siu H. Chan

    2012-02-01

    Full Text Available Vascular stiffness has been proposed as a simple method to assess arterial loading conditions of the heart which induce left ventricular hypertrophy (LVH. There is some controversy as to whether the relationship of vascular stiffness to LVH is independent of blood pressure, and which measurement of arterial stiffness, augmentation index (AI or pulse wave velocity (PWV is best. Carotid pulse wave contor and pulse wave velocity of patients (n=20 with hypertension whose blood pressure (BP was under control (<140/90 mmHg with antihypertensive drug treatment medications, and without valvular heart disease, were measured. Left ventricular mass, calculated from 2D echocardiogram, was adjusted for body size using two different methods: body surface area and height. There was a significant (P<0.05 linear correlation between LV mass index and pulse wave velocity. This was not explained by BP level or lower LV mass in women, as there was no significant difference in PWV according to gender (1140.1+67.8 vs 1110.6+57.7 cm/s. In contrast to PWV, there was no significant correlation between LV mass and AI. In summary, these data suggest that aortic vascular stiffness is an indicator of LV mass even when blood pressure is controlled to less than 140/90 mmHg in hypertensive patients. The data further suggest that PWV is a better proxy or surrogate marker for LV mass than AI and the measurement of PWV may be useful as a rapid and less expensive assessment of the presence of LVH in this patient population.

  3. One nanosecond pulsed electron gun systems

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1979-02-01

    At SLAC there has been a continuous need for the injection of very short bunches of electrons into the accelerator. Several time-of-flight experiments have used bursts of short pulses during a normal 1.6 micro-second rf acceleration period. Single bunch beam loading experiments made use of a short pulse injection system which included high power transverse beam chopping equipment. Until the equipment described in this paper came on line, the basic grid-controlled gun pulse was limited to a rise time of 7 nanoseconds and a pulse width of 10 nanoseconds. The system described here has a grid-controlled rise time of less than 500 pico-seconds, and a minimum pulse width of less than 1 nanosecond. Pulse burst repetition rate has been demonstrated above 20 MHz during a 1.6 microsecond rf accelerating period. The order-of-magnitude increase in gun grid switching speed comes from a new gun design which minimizes lead inductance and stray capacitance, and also increases gun grid transconductance. These gun improvements coupled with a newly designed fast pulser mounted directly within the gun envelope make possible subnanosecond pulsing of the gun

  4. Detection of the Typical Pulse Condition on Cun-Guan-Chi Based on Image Sensor

    Directory of Open Access Journals (Sweden)

    Aihua ZHANG

    2014-02-01

    Full Text Available In order to simulate the diagnosis by feeling the pulse with Traditional Chinese Medicine, a device based on CCD was designed to detect the pulse image of Cun-Guan-Chi. Using the MM-3 pulse model as experimental subject, the synchronous pulse image data of some typical pulse condition were collected by this device on Cun-Guan-Chi. The typical pulses include the normal pulse, the slippery pulse, the slow pulse and the soft pulse. According to the lens imaging principle, the pulse waves were extracted by using the area method, then the 3D pulse condition image was restructured and some features were extracted including the period, the frequency, the width, and the length. The slippery pulse data of pregnant women were collected by this device, and the pulse images were analyzed. The results are consistent based on comparing the features of the slippery pulse model with the slippery pulse of pregnant women. This study overcame shortages of the existing detection device such as the few detecting parts and the limited information, and more comprehensive 3D pulse condition information could be obtained. This work laid a foundation for realizing the objective diagnosis and revealing the comprehensive information of the pulse.

  5. Optimum filters with time width constraints for liquid argon total-absorption detectors

    International Nuclear Information System (INIS)

    Gatti, E.; Radeka, V.

    1977-10-01

    Optimum filter responses are found for triangular current input pulses occurring in liquid argon ionization chambers used as total absorption detectors. The filters considered are subject to the following constraints: finite width of the output pulse having a prescribed ratio to the width of the triangular input current pulse and zero area of a bipolar antisymmetrical pulse or of a three lobe pulse, as required for high event rates. The feasibility of pulse shaping giving an output equal to, or shorter than, the input one is demonstrated. It is shown that the signal-to-noise ratio remains constant for the chamber interelectrode gap which gives an input pulse width (i.e., electron drift time) greater than one third of the required output pulse width

  6. Programmable pulse generator

    International Nuclear Information System (INIS)

    Xue Zhihua; Lou Binqiao; Duan Xiaohui

    2002-01-01

    The author introduces the design of programmable pulse generator that is based on a micro-controller and controlled by RS232 interface of personal computer. The whole system has good stability. The pulse generator can produce TTL pulse and analog pulse. The pulse frequency can be selected by EPLD. The voltage amplitude and pulse width of analog pulse can be adjusted by analog switches and digitally-controlled potentiometers. The software development tools of computer is National Instruments LabView5.1. The front panel of this virtual instrumentation is intuitive and easy-to-use. Parameters can be selected and changed conveniently by knob and slide

  7. Greenup and evapotranspiration following the Minute 319 pulse flow to Mexico: An analysis using Landsat 8 Normalized Difference Vegetation Index (NDVI) data

    Science.gov (United States)

    Jarchow, Christopher J.; Nagler, Pamela L.; Glenn, Edward P.

    2017-01-01

    In the southwestern U.S., many riparian ecosystems have been altered by dams, water diversions, and other anthropogenic activities. This is particularly true of the Colorado River, where numerous dams and agricultural diversions have affected this water course, especially south of the U.S.–Mexico border. In the spring of 2014, 130 million cubic meters of water was released to the lower Colorado River Delta in Mexico. To understand the impact of this pulse flow release on vegetation in the delta’s riparian corridor, we analyzed a modified form of Landsat 8 Operational Land Imager (OLI) Normalized Difference Vegetation Index (NDVI*) data. We assessed greenup during the growing period and estimated actual evapotranspiration (ETa) for the period prior to (yr. 2013) and following (i.e., yr. 2014 and 2015) the pulse flow. We found a significant increase in NDVI* from 2013 to 2014 (P NDVI*. As a long term solution to the declining condition of vegetation, additional pulse releases are likely needed for restoration and survival of riparian plant communities in the Colorado River Delta.

  8. Thermo mechanical design of normal-conducting deflecting cavities at the Advanced Photon Source for short x-ray pulse generation.

    Energy Technology Data Exchange (ETDEWEB)

    Brajuskovic, B.; Collins, J.; Den Hartog, P.; Morrison, L.; Waldschmidt, G.

    2008-01-01

    A normal-conducting deflecting cavity is being designed at the Advanced Photon Source (APS) as a part of the short x-ray pulse project intended to provide users with approximately 2 picosecond x-rays. The system will use two pairs of 3-cell cavities in sectors 6ID and 7ID for the generation of the x-ray pulse in the 7ID beamline. The 3-cell cavities are designed to provide the desired beam deflection while absorbing in excess of 4 kW of power from a pulsed rf system and up to 2.6 kW in the damper system of high-order mode (HOM) and low-order mode (LOM) waveguides. Since the cavity frequency is very sensitive to thermal expansion, the cooling water system is designed so that it is able to control cavity temperature to within 0.1 C. This paper describes the optimization of the thermomechanical design of the cavity based on calculation of thermal stresses and displacement caused by the generated heat loads, and presents the design of a cooling water system required for the proper operation of the cavities.

  9. SU-E-T-501: Normal Tissue Toxicities of Pulsed Low Dose Rate Radiotherapy and Conventional Radiotherapy: An in Vivo Total Body Irradiation Study

    Energy Technology Data Exchange (ETDEWEB)

    Cvetkovic, D; Zhang, P; Wang, B; Chen, L; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2014-06-01

    Purpose: Pulsed low dose rate radiotherapy (PLDR) is a re-irradiation technique for therapy of recurrent cancers. We have previously shown a significant difference in the weight and survival time between the mice treated with conventional radiotherapy (CRT) and PLDR using total body irradiation (TBI). The purpose of this study was to investigate the in vivo effects of PLDR on normal mouse tissues.Materials and Methods: Twenty two male BALB/c nude mice, 4 months of age, were randomly assigned into a PLDR group (n=10), a CRT group (n=10), and a non-irradiated control group (n=2). The Siemens Artiste accelerator with 6 MV photon beams was used. The mice received a total of 18Gy in 3 fractions with a 20day interval. The CRT group received the 6Gy dose continuously at a dose rate of 300 MU/min. The PLDR group was irradiated with 0.2Gyx20 pulses with a 3min interval between the pulses. The mice were weighed thrice weekly and sacrificed 2 weeks after the last treatment. Brain, heart, lung, liver, spleen, gastrointestinal, urinary and reproductive organs, and sternal bone marrow were removed, formalin-fixed, paraffin-embedded and stained with H and E. Morphological changes were observed under a microscope. Results: Histopathological examination revealed atrophy in several irradiated organs. The degree of atrophy was mild to moderate in the PLDR group, but severe in the CRT group. The most pronounced morphological abnormalities were in the immune and hematopoietic systems, namely spleen and bone marrow. Brain hemorrhage was seen in the CRT group, but not in the PLDR group. Conclusions: Our results showed that PLDR induced less toxicity in the normal mouse tissues than conventional radiotherapy for the same dose and regimen. Considering that PLDR produces equivalent tumor control as conventional radiotherapy, it would be a good modality for treatment of recurrent cancers.

  10. Width of electromagnetic wave instability spectrum in tungsten plate

    International Nuclear Information System (INIS)

    Rinkevich, A.B.

    1995-01-01

    Based on the study of high-frequency signal modulation and spectrum analysis of the envelope a measurement of spectrum width for electromagnetic wave instability was carried out under conditions of current pulse action on tungsten plate in magnetic field. The existence of amplitude-frequency wave modulation was revealed. The width of current disturbance spectrum in a specimen was evaluated. Current disturbances are shown to cause the instability of electromagnetic wave. 11 refs.; 6 figs

  11. Two-dimensional turning of thermal flux from normal to lateral propagation in thin metal film irradiated by femtosecond laser pulse

    Science.gov (United States)

    Shepelev, V. V.; Inogamov, N. A.

    2018-01-01

    There are various geometrical variants of laser illumination and target design. Important direction of investigations is connected with tightly focused action (spot size may be less than micron) onto a thin metal film: thickness of a film is just few skin-layer depths. Duration of a pulse is τ L ˜ 0.1 ps. In these conditions energy absorbed in a skin layer first propagates normally to a surface: gradient ∂Te /∂x dominates, here and below x and y are normal and lateral directions. This process in 1-2 ps homogenizes electron temperature T e along thickness of a film. We consider conditions when a film or is supported by weakly conducting substrate, or is free standing. Therefore all absorbed energy is confined inside the film. At the next stage the internal energy begin to flow along the lateral direction—thus direction of energy expansion is changed from x to y because of the heat non-penetrating boundary condition imposed on the rear-side of the film. At the short two-temperature stage of lateral expansion the thermal conductivity κ is high. After that electron and ion temperatures equilibrates and later on the heat propagates with usual value of κ. Lateral expansion cools down the hot spot on long time scales and finally the molten spot recrystallizes. Two-dimensional approach allows us to consider all these stages from propagation in x direction (normal to a film) to propagation in y direction (along a film).

  12. Plasma Renalase is Not Associated with Blood Pressure and Brachial-Ankle Pulse Wave Velocity in Chinese Adults With Normal Renal Function

    Directory of Open Access Journals (Sweden)

    Yang Wang

    2016-11-01

    Full Text Available Background/Aims: This study aimed to investigate the association of renalase with blood pressure (BP and brachial-ankle pulse wave velocity (baPWV in order to better understand the role of renalase in the pathogenesis of hypertension and atherosclerosis. Methods: A total of 344 subjects with normal kidney function were recruited from our previously established cohort in Shaanxi Province, China. They were divided into the normotensive (NT and hypertensive (HT groups or high baPWV and normal baPWV on the basis of BP levels or baPWV measured with an automatic waveform analyzer. Plasma renalase was determined through an enzyme-linked immunosorbent assay. Results: Plasma renalase did not significantly differ between HT and NT groups (3.71 ± 0.69 µg/mL vs. 3.72 ± 0.73 μg/mL, P = 0.905 and between subjects with and without high baPWV (3.67 ± 0.66 µg/mL vs. 3.73 ± 0.74 µg/mL, P = 0.505. However, baPWV was significantly higher in the HT group than in the NT group (1460.4 ± 236.7 vs. 1240.7 ± 174.5 cm/s, P Conclusion: Plasma renalase may not be associated with BP and baPWV in Chinese subjects with normal renal function.

  13. Resolving single bubble sonoluminescence flask width

    OpenAIRE

    Arakeri, Vijay H

    1998-01-01

    Single bubble sonoluminescence (SBSL), first studied and observed by Gaitan et al., is the of light emission from a single gas bubble trapped at the pressure maximum of a resonant sound field in a liquid medium, generally water. One of the most striking aspects of SBSL was the estimated optical flash width being less than 50 picoseconds (ps)3; this upper estimate was based on the relative response of a SBSL flash in comparison to a 34 ps laser pulse using a microchannel platephotomultiplier ...

  14. SINGLE-PULSE RADIO OBSERVATIONS OF THE GALACTIC CENTER MAGNETAR PSR J1745–2900

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Zhen; Shen, Zhi-Qiang; Wu, Ya-Jun; Zhao, Rong-Bing; Fan, Qing-Yuan; Hong, Xiao-Yu; Jiang, Dong-Rong; Li, Bin; Liang, Shi-Guang; Ling, Quan-Bao; Liu, Qing-Hui; Qian, Zhi-Han; Zhang, Xiu-Zhong; Zhong, Wei-Ye; Ye, Shu-Hua [Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030 (China); Wu, Xin-Ji [Department of Astronomy, Peking University, Beijing 100871 (China); Manchester, R. N. [CSIRO Astronomy and Space Science, P.O. Box 76, Epping, NSW 1710 (Australia); Weltevrede, P. [Jodrell Bank Centre for Astrophysics, School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); Yuan, Jian-Ping [Key Laboratory of Radio Astronomy, Chinese Academy of Sciences (China); Lee, Ke-Jia, E-mail: yanzhen@shao.ac.cn [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2015-11-20

    In this paper, we report radio observations of the Galactic Center magnetar PSR J1745–2900 at six epochs between 2014 June and October. These observations were carried out using the new Shanghai Tian Ma Radio Telescope at a frequency of 8.6 GHz. Both the flux density and integrated profile of PSR J1745–2900 show dramatic changes from epoch to epoch, showing that the pulsar was in its “erratic” phase. On MJD 56836, the flux density of this magnetar was about 8.7 mJy, which was 10 times larger than that reported at the time of discovery, enabling a single-pulse analysis. The emission is dominated by narrow “spiky” pulses that follow a log-normal distribution in peak flux density. From 1913 pulses, we detected 53 pulses whose peak flux densities are 10 times greater than that of the integrated profile. They are concentrated in pulse phase at the peaks of the integrated profile. The pulse widths at the 50% level of these bright pulses were between 0.°2 and 0.°9, much narrower than that of the integrated profile (∼12°). The observed pulse widths may be limited by interstellar scattering. No clear correlation was found between the widths and peak flux density of these pulses and no evidence was found for subpulse drifting. Relatively strong spiky pulses are also detected in the other five epochs of observation, showing the same properties as those detected in MJD 56836. These strong spiky pulses cannot be classified as “giant” pulses but are more closely related to normal pulse emission.

  15. Controllable Pulse Frequency and Width System for Pulsing and Modulating Fast-Neutron Core Assemblies; Systeme a Frequence et Largeur d'Impulsions Ajustables Permettant la Pulsation et la Modulation de Milieux Multipliants Sous-Critiques a Neutrons Rapides; Sistema reguliruemykh chastoty i shiriny impul'sa, dayushaya impul's i modulyatsiyu razmnozhayushchikh sred na bystrykh nejtronakh; Sistema de Frecuencia y Amplitud de Impulso Ajustables, para Pulsar y Modular

    Energy Technology Data Exchange (ETDEWEB)

    Duquesne, M.; Lyon, F.; Schmitt, A. [Association Euratom-CEA-SECNR (France); Nucleaires de Cadarache, Centre d' Etudes [France; Gerbier, R. [Laboratoire des Accelerateurs - CEN de Grenoble (France); Nucleaires de Cadarache, Centre d' Etudes [France

    1965-10-15

    The authors describe a system for producing neutron bursts of independently controllable width and frequency. The rise and quenching times of these bursts are of the order of a few nanoseconds. The system is applied to high-frequency pulsed and modulated experiments. Rapidly quenched neutron bursts are produced by deflection of a pure deuteron beam which has previously been accelerated and sorted. Ions other than atomic deuterons are removed after acceleration in a 10 Degree-Sign magnetic sorting field. Consideration is also being given to a pre-acceleration sorting system offering the advantage of reduced bulk. The deuteron beam passes through the space between two plates where there is normally an electrostatic field which deflects the beam onto the surfaces of a diaphragm. Application of a very high potential pulse to the first plate cancels the field and thus brings the beam rapidly onto the neutron-producing target (beginning of the burst). The second plate then receives a pulse of the same type which restores the field and removes the beam from the target (end of the burst). The pulse rise time is of the order of 10 ns; disappearance from the target is faster. The duration of the burst can be controlled as required within reasonable limits by suitably increasing the interval between the two pulses. In some cases ion transit time in the plates is not negligible in relation to the duration of the step applied to them. In such cases, one of the plates is replaced by a travelling wave line to which the two pulses are applied successively. The potential pulse thus accompanies the deuteron cluster producing the burst. The burst times can thus be reduced below 4 ns. The first stages of the voltage step generators are transistorized. The output tubes are sealed-disc valves providing a 1500-V step in a few nanoseconds. A 50-MHz double tetrode is employed for pulses for the delay line. A detection system comprises a scintillator-photomultiplier device incorporating a

  16. Modified model of neutron resonance widths distribution. Results of total gamma-widths approximation

    International Nuclear Information System (INIS)

    Sukhovoj, A.M.; Khitrov, V.A.

    2011-01-01

    Functional dependences of probability to observe given Γ n 0 value and algorithms for determination of the most probable magnitudes of the modified model of resonance parameter distributions were used for analysis of the experimental data on the total radiative widths of neutron resonances. As in the case of neutron widths, precise description of the Γ γ spectra requires a superposition of three and more probability distributions for squares of the random normally distributed values with different nonzero average and nonunit dispersion. This result confirms the preliminary conclusion obtained earlier at analysis of Γ n 0 that practically in all 56 tested sets of total gamma widths there are several groups noticeably differing from each other by the structure of their wave functions. In addition, it was determined that radiative widths are much more sensitive than the neutron ones to resonance wave functions structure. Analysis of early obtained neutron reduced widths distribution parameters for 157 resonance sets in the mass region of nuclei 35 ≤ A ≤ 249 was also performed. It was shown that the experimental values of widths can correspond with high probability to superposition of several expected independent distributions with their nonzero mean values and nonunit dispersion

  17. Plasma Renalase is Not Associated with Blood Pressure and Brachial-Ankle Pulse Wave Velocity in Chinese Adults With Normal Renal Function.

    Science.gov (United States)

    Wang, Yang; Lv, Yong-Bo; Chu, Chao; Wang, Man; Xie, Bing-Qing; Wang, Lan; Yang, Fan; Yan, Ding-Yi; Yang, Rui-Hai; Yang, Jun; Ren, Yong; Yuan, Zu-Yi; Mu, Jian-Jun

    2016-01-01

    This study aimed to investigate the association of renalase with blood pressure (BP) and brachial-ankle pulse wave velocity (baPWV) in order to better understand the role of renalase in the pathogenesis of hypertension and atherosclerosis. A total of 344 subjects with normal kidney function were recruited from our previously established cohort in Shaanxi Province, China. They were divided into the normotensive (NT) and hypertensive (HT) groups or high baPWV and normal baPWV on the basis of BP levels or baPWV measured with an automatic waveform analyzer. Plasma renalase was determined through an enzyme-linked immunosorbent assay. Plasma renalase did not significantly differ between HT and NT groups (3.71 ± 0.69 µg/mL vs. 3.72 ± 0.73 μg/mL, P = 0.905) and between subjects with and without high baPWV (3.67 ± 0.66 µg/mL vs. 3.73 ± 0.74 µg/mL, P = 0.505). However, baPWV was significantly higher in the HT group than in the NT group (1460.4 ± 236.7 vs. 1240.7 ± 174.5 cm/s, P function. © 2016 The Author(s) Published by S. Karger AG, Basel.

  18. Random pulse generator

    International Nuclear Information System (INIS)

    Guo Ya'nan; Jin Dapeng; Zhao Dixin; Liu Zhen'an; Qiao Qiao; Chinese Academy of Sciences, Beijing

    2007-01-01

    Due to the randomness of radioactive decay and nuclear reaction, the signals from detectors are random in time. But normal pulse generator generates periodical pulses. To measure the performances of nuclear electronic devices under random inputs, a random generator is necessary. Types of random pulse generator are reviewed, 2 digital random pulse generators are introduced. (authors)

  19. Time moments of the energy flow of optical pulses in highly dispersive media

    International Nuclear Information System (INIS)

    Nanda, Lipsa; Wanare, Harshawardhan; Ramakrishna, S Anantha

    2010-01-01

    We use the time moments of the Poynting vector associated with an electromagnetic pulse to characterize the traversal times and temporal pulse widths as the pulse propagates in highly dispersive media. The behaviour of these quantities with the propagation distance is analysed in three canonical cases: Lorentz absorptive medium, a Raman gain doublet amplifying medium and a medium exhibiting electromagnetically induced transparency. We find that superluminal pulse propagation in the first two cases with anomalous dispersion is usually accompanied by pulse compression and eventually the pulse becomes subluminal with increasing distance of propagation. In a medium with electromagnetically induced transparency with large normal dispersion, we identify a range of frequencies for which the pulse undergoes minimal temporal expansion while propagating with ultra-slow speed.

  20. Probabilistic Analysis of Crack Width

    Directory of Open Access Journals (Sweden)

    J. Marková

    2000-01-01

    Full Text Available Probabilistic analysis of crack width of a reinforced concrete element is based on the formulas accepted in Eurocode 2 and European Model Code 90. Obtained values of reliability index b seem to be satisfactory for the reinforced concrete slab that fulfils requirements for the crack width specified in Eurocode 2. However, the reliability of the slab seems to be insufficient when the European Model Code 90 is considered; reliability index is less than recommended value 1.5 for serviceability limit states indicated in Eurocode 1. Analysis of sensitivity factors of basic variables enables to find out variables significantly affecting the total crack width.

  1. A deterministic width function model

    Directory of Open Access Journals (Sweden)

    C. E. Puente

    2003-01-01

    Full Text Available Use of a deterministic fractal-multifractal (FM geometric method to model width functions of natural river networks, as derived distributions of simple multifractal measures via fractal interpolating functions, is reported. It is first demonstrated that the FM procedure may be used to simulate natural width functions, preserving their most relevant features like their overall shape and texture and their observed power-law scaling on their power spectra. It is then shown, via two natural river networks (Racoon and Brushy creeks in the United States, that the FM approach may also be used to closely approximate existing width functions.

  2. Pulse-width modulation for small heat pump installations - Phase 2: implementation in a commercial controller and tests in a residential building; Pulsbreitenmodulation fuer Kleinwaermepumpenanlagen. Phase 2: Implementierung in handelsuebliche Regler und Erprobung in einem Wohnhaus

    Energy Technology Data Exchange (ETDEWEB)

    Gabathuler, H.R.; Mayer, H. [Gabathuler AG, Diessenhofen (Switzerland); Shafai, E.; Wimmer, R. [Eidgenoessische Technische Hochschule, Institut fuer Mess- und Regeltechnik, Zuerich (Switzerland); Frei, R. [Satag Thermotechnik AG, Arbon (Switzerland); Illi, B.; Sidler, F. [Siemens Building Technologies AG, Zug (Switzerland)

    2002-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project in which a new type of controller for small heat pumps used to heat single-family houses was developed. Instead of the two-point controller normally used to control flow or return temperatures in the heating system, three new approaches are described that deliver the heating energy required for a whole day in portions according to prevailing weather conditions and the thermal characteristics of the house and the heat pump. Electricity tariffs are also taken into account and peak-rate periods avoided. The results of the investigations show that all three variants can be implemented using commercially available controllers. Further investigations, including a complete and representative comparison of the three concepts and a conventional control system are foreseen in phase 3 of the project.

  3. Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: towards applications in ambulatory monitoring

    International Nuclear Information System (INIS)

    Lee, Jihyoung; Matsumura, Kenta; Yamakoshi, Takehiro; Tanaka, Naoto; Yamakoshi, Ken-ichi; Rolfe, Peter; Kim, Kyungho

    2013-01-01

    Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress. (paper)

  4. Method and equipment for fast transmission of a signal consisting of many data pulses by a normal well-logging cable

    International Nuclear Information System (INIS)

    Pitts, R.W. Jr.; Whatley, H.A. Jr.

    1975-01-01

    Well logging methods and equipment in general and a nuclear well logging process and apparatus in particular are presented. They increase the number of pulses which can be transmitted to the top of the well from a well logging instrument placed at the bottom, during a given time interval, by means of a processing giving two pulses for each pulse corresponding to a detection. The equipment is a double-spectrum well logging system, with near and far detectors [fr

  5. Spherical bodies of constant width

    OpenAIRE

    Lassak, Marek; Musielak, Michał

    2018-01-01

    The intersection $L$ of two different non-opposite hemispheres $G$ and $H$ of a $d$-dimensional sphere $S^d$ is called a lune. By the thickness of $L$ we mean the distance of the centers of the $(d-1)$-dimensional hemispheres bounding $L$. For a hemisphere $G$ supporting a %spherical convex body $C \\subset S^d$ we define ${\\rm width}_G(C)$ as the thickness of the narrowest lune or lunes of the form $G \\cap H$ containing $C$. If ${\\rm width}_G(C) =w$ for every hemisphere $G$ supporting $C$, we...

  6. Fast quadrupole pulsed power supply in the AGS

    International Nuclear Information System (INIS)

    Nawrocky, R.J.; Halama, H.J.; Lambiase, R.F.; Montemurro, P.A.

    1984-01-01

    As part of the Polarized Proton Project at the AGS, a pulsed power supply system has been developed to energize a set of twelve fast quadrupoles which are symmetrically distributed around the 1/2-mile circumference of the machine. During a typical acceleration cycle, which is normally repeated every 2.4 s, these magnets are energized with bursts of triangular current pulses. The rise-time of each pulse is less than 2 μs and the width at the base varies from 1 to 3.5 ms depending on the pulse. Within a burst, pulses alternate in polarity and vary in amplitude from 160 A to 2700 A peak. Pulse separation is on the order of 40 ms. Due to the distributed nature of the load and high di/dt, each magnet is powered by a separate modulator. Magnets are driven via coaxial pulse transmission cables up to 200 ft long. In the modulators, the high power pulses are switched with thyratron/ignitron switch pairs. All modulators are charged in parallel with a common system of programmable high voltage power supplies. The overall system is controlled with a distributed network of microcomputers. This paper describes the development, construction and initial performance of the pulsed power supply system

  7. Novel zero voltage transition pulse width modulation flyback converter

    Science.gov (United States)

    Adib, Ehsan; Farzanehfard, Hosein

    2010-09-01

    In this article, a new zero voltage (ZV) transition flyback converter is introduced which uses a simple auxiliary circuit. In this converter, ZV switching condition is achieved for the converter switch while zero current switching condition is attained for the auxiliary switch. There is no additional voltage and current stress on the main switch. Main diode, auxiliary circuit voltage and current ratings are low. The proposed converter is analysed and design procedure is discussed. The presented experimental results of a prototype converter justify the theoretical analysis.

  8. Optimized Pulse Width Modulation for transformerless active-NPC inverters

    DEFF Research Database (Denmark)

    Achilladelis, Nikolaos; Koutroulis, Eftichios; Blaabjerg, Frede

    2014-01-01

    The transformerless DC/AC inverter topologies are employed in Photovoltaic systems in order to improve the power conversion efficiency, power density and cost. The Active-Neutral Point Clamped (Active-NPC) transformerless inverters have the advantage of achieving better thermal balance among thei...

  9. Using the local positioning system based on Pulse Width Modulation ...

    African Journals Online (AJOL)

    There are many ways to estimate the location of a moving object. One way is to determine its location using a GPS which calculates longitude and latitude of the object by the data received by the satellites rotating around the earth. However, there are no devices to recover calculated inherent errors and have an appropriate ...

  10. Influence of diffuse goiter on tracheal width

    International Nuclear Information System (INIS)

    Baik, Sung Mo; Shon, Hyung Sun; Kim, Choon Yul; Bahk, Yong Whee

    1980-01-01

    The radioisotopic scanning of the thyroid gland is well established method of demonstrating morphology of the thyroid gland and is used to measure the size, area and weight of thyroid gland. The purpose of this investigation is to observe the various effects of goiter to the regional trachea. Both radioisotopic scanning and roentgenogram were taken at the same time to evaluate size, area and weight of the thyroid glands, as well as to measure the width of soft tissue structure of the neck and the regional trachea in normal and goitrous patients. The clinical materials consisted of normal thyroid group for control (46 cases), diffuse simple goiter group (76 cases) and Graves' disease group (59 cases). The results were as follows; 1. The goiter causes some narrowing of the regional trachea to various degree which is not necessarily reflective of the size of goiter. 2. The goiter may increase the width of retrotracheal soft tissue space. 3. The lateral roentgenogram of the neck appear very useful in estimating the thyroid gland three dimensionally and the effect of goiter to the regional trachea

  11. Normal and grazing incidence pulsed laser deposition of nanostructured MoSx hydrogen evolution catalysts from a MoS2 target

    Science.gov (United States)

    Fominski, V. Yu.; Romanov, R. I.; Fominski, D. V.; Dzhumaev, P. S.; Troyan, I. A.

    2018-06-01

    Pulsed laser ablation of a MoS2 target causes enhanced splashing of the material. So, for MoSx films obtained by pulsed laser deposition (PLD) in the conventional normal incidence (NI) configuration, their typical morphology is characterized by an underlying granular structure with an overlayer of widely dispersed spherical Mo and MoSx particles possessing micro-, sub-micro- and nanometer sizes. We investigated the possibility of using high surface roughness, which occurs due to particle deposition, as a support with a large exposed surface area for thin MoSx catalytic layers for the hydrogen evolution reaction (HER). For comparison, the HER performance of MoSx layers formed by grazing incidence (GI) PLD was studied. During GI-PLD, a substrate was placed along the direction of laser plume transport and few large particles loaded the substrate. The local structure and composition of thin MoSx layers formed by the deposition of the vapor component of the laser plume were varied by changing the pressure of the buffer gas (argon, Ar). In the case of NI-PLD, an increase in Ar pressure caused the formation of quasi-amorphous MoSx (x ≥ 2) films that possessed highly active catalytic sites on the edges of the layered MoS2 nanophase. At the same time, a decrease in the deposition rate of the MoSx film appeared due to the scattering of the vapor flux by Ar molecules during flux transport from the target to the substrate. This effect prevented uniform deposition of the MoSx catalytic film on the surface of most particles, whose deposition rate was independent of Ar pressure. The scattered vapor flux containing Mo and S atoms was a dominant source for MoSx film growth during GI-PLD. The thickness and composition distribution of the MoSx film on the substrate depended on both the pressure of the buffer gas and the distance from the target. For 1.0-2.5 cm from the target, the deposition rate was quite sufficient to form S-enriched quasi-amorphous MoSx (2.5 < x < 6) catalytic

  12. On the maximal diphoton width

    CERN Document Server

    Salvio, Alberto; Strumia, Alessandro; Urbano, Alfredo

    2016-01-01

    Motivated by the 750 GeV diphoton excess found at LHC, we compute the maximal width into $\\gamma\\gamma$ that a neutral scalar can acquire through a loop of charged fermions or scalars as function of the maximal scale at which the theory holds, taking into account vacuum (meta)stability bounds. We show how an extra gauge symmetry can qualitatively weaken such bounds, and explore collider probes and connections with Dark Matter.

  13. Masses, widths, and leptonic widths of the higher upsilon resonances

    International Nuclear Information System (INIS)

    Lovelock, D.M.J.; Horstkotte, J.E.; Klopfenstein, C.

    1985-01-01

    The masses, total widths, and leptonic widths of three triplet s-wave bb-bar states UPSILON(4S), UPSILON(5S), and UPSILON(6S) are determined from measurements of the e + e - annihilation cross section into hadrons for 10.55< W<11.25 GeV. The resonances are identified from potential model results and their properties are obtained with the help of a simplified coupled-channels calculation. We find M(4S) = 10.577 GeV, GAMMA(4S) = 25 MeV, GAMMA/sub e/e(4S) = 0.28 keV; M(5S) = 10.845 GeV, GAMMA(5S) = 110 MeV, GAMMA/sub e/e(5S) = 0.37 keV; M(6S) = 11.02 GeV, GAMMA(6S) = 90 MeV, GAMMA/sub e/e(6S) = 0.16 keV

  14. Masses, widths and leptonic widths of the higher upsilon resonances

    International Nuclear Information System (INIS)

    Klopfenstein, C.; Lovelock, D.M.J.; Horstkotte, J.E.

    1985-01-01

    The masses, total widths and leptonic widths of three triplet s-wave bb-bar states Υ(4S), Υ(5S) and Υ(6S) are determined by unfolding the cross section features observed in the hadronic cross section in the √s region betweeen 10.55 to 11.25 GeV. Both the identification of the resonances and the deduction of their properties rely on the validity of potential models' description of heavy quarkonium states which lie close (<0.6 GeV) to the open flavor threshold. The authors find M(4S) = 10.5774 +- 0.0008 GeV, Γ(4S) = 23 +- 2.3 MeV, Γ/sub ee/(4S) = 0.28 +- 0.04 keV; M(5S) = 10.845 +- 0.02 GeV, Γ(5S) = 110 +- 15 MeV, Γ/sub ee/(5S) = 0.37 +- 0.06 keV; M(6S) = 11.02 +- 0.03 GeV, Γ(6S) = 90 +- 20 MeV, Γ/sub ee/(6S) = 0.16 +- 0.04 keV. All errors are statistical only

  15. Tourniquet pressures: strap width and tensioning system widths.

    Science.gov (United States)

    Wall, Piper L; Coughlin, Ohmar; Rometti, Mary; Birkholz, Sarah; Gildemaster, Yvonne; Grulke, Lisa; Sahr, Sheryl; Buising, Charisse M

    2014-01-01

    Pressure distribution over tourniquet width is a determinant of pressure needed for arterial occlusion. Different width tensioning systems could result in arterial occlusion pressure differences among nonelastic strap designs of equal width. Ratcheting Medical Tourniquets (RMTs; m2 inc., http://www.ratcheting buckles.com) with a 1.9 cm-wide (Tactical RMT) or 2.3 cm-wide (Mass Casualty RMT) ladder were directly compared (16 recipients, 16 thighs and 16 upper arms for each tourniquetx2). Then, RMTs were retrospectively compared with the windlass Combat Application Tourniquet (C-A-T ["CAT"], http://combattourniquet.com) with a 2.5 cm-wide internal tensioning strap. Pressure was measured with an air-filled No. 1 neonatal blood pressure cuff under each 3.8 cm-wide tourniquet. RMT circumferential pressure distribution was not uniform. Tactical RMT pressures were not higher, and there were no differences between the RMTs in the effectiveness, ease of use ("97% easy"), or discomfort. However, a difference did occur regarding tooth skipping of the pawl during ratchet advancement: it occurred in 1 of 64 Tactical RMT applications versus 27 of 64 Mass Casualty RMT applications. CAT and RMT occlusion pressures were frequently over 300 mmHg. RMT arm occlusion pressures (175-397 mmHg), however, were lower than RMT thigh occlusion pressures (197-562 mmHg). RMT effectiveness was better with 99% reached occlusion and 1% lost occlusion over 1 minute versus the CAT with 95% reached occlusion and 28% lost occlusion over 1 minute. RMT muscle tension changes (up to 232 mmHg) and pressure losses over 1 minute (24±11 mmHg arm under strap to 40±12 mmHg thigh under ladder) suggest more occlusion losses may have occurred if tourniquet duration was extended. The narrower tensioning system Tactical RMT has better performance characteristics than the Mass Casualty RMT. The 3.8 cm-wide RMTs have some pressure and effectiveness similarities and differences compared with the CAT. Clinically

  16. Pulsed neutron sources at KAON

    International Nuclear Information System (INIS)

    Thorson, I.M.; Egelstaff, P.A.; Craddock, M.K.

    1991-01-01

    The proposed KAON Factory facility at TRIUMF consists of a number of synchrotrons and storage rings which offer proton beams of energies between 0.45 and 30 GeV with varying pulse amplitudes, widths and repetition rates. Various possibilities for feeding these beams to a pulsed neutron facility and their potential for future development are examined. The incremental cost of such a pulsed neutron facility is estimated approximately. (author)

  17. Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: 'establishing normal and reference values'

    DEFF Research Database (Denmark)

    Hansen, Tine Willum

    2010-01-01

    Carotid-femoral pulse wave velocity (PWV), a direct measure of aortic stiffness, has become increasingly important for total cardiovascular (CV) risk estimation. Its application as a routine tool for clinical patient evaluation has been hampered by the absence of reference values. The aim of the ...

  18. Slow light pulse propagation in dispersive media

    DEFF Research Database (Denmark)

    Nielsen, Torben Roland; Mørk, Jesper; Lavrinenko, Andrei

    2009-01-01

    broadening or break-up of the pulse may be observed. The transition from linear to nonlinear pulse propagation is quantified in terms of the spectral width of the pulse. To cite this article: T.R. Nielsen et al., C. R. Physique 10 (2009). (C) 2009 Academie des sciences. Published by Elsevier Masson SAS. All...... rights reserved....

  19. Comparison of Arch Width Changes Following Orthodontic ...

    African Journals Online (AJOL)

    2015-11-21

    Nov 21, 2015 ... Materials and Methods: The study was conducted with pre- and post-treatment digital models from ... or posterior arch width following orthodontic treatment ..... premolar extraction cases show significant arch width increases in ...

  20. S100 lathe bed pulse generator applied to pulsed nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Cernicchiaro, G.R.C.; Rudge, M.G.; Albuquerque, M.P.

    1989-01-01

    The project and construction of four channel pulse generator in the S100 standard plate and its control software for microcomputer are described. The microcomputer has total control on the pulse generator, which has seven programable parameters, defining the position of four pulses and the width for the three first ones. This pulse generator is controlled by a software developed in c language, and is used in pulsed nuclear magnetic resonance experiences. (M.C.K.) [pt

  1. Neutron fluctuation analysis in a subcritical multiplying system with a stochastically pulsed poisson source

    International Nuclear Information System (INIS)

    Kostic, Lj.

    2003-01-01

    The influence of the stochastically pulsed Poisson source to the statistical properties of the subcritical multiplying system is analyzed in the paper. It is shown a strong dependence on the pulse period and pulse width of the source (author)

  2. EVOLUTION OF FAST MAGNETOACOUSTIC PULSES IN RANDOMLY STRUCTURED CORONAL PLASMAS

    International Nuclear Information System (INIS)

    Yuan, D.; Li, B.; Pascoe, D. J.; Nakariakov, V. M.; Keppens, R.

    2015-01-01

    We investigate the evolution of fast magnetoacoustic pulses in randomly structured plasmas, in the context of large-scale propagating waves in the solar atmosphere. We perform one-dimensional numerical simulations of fast wave pulses propagating perpendicular to a constant magnetic field in a low-β plasma with a random density profile across the field. Both linear and nonlinear regimes are considered. We study how the evolution of the pulse amplitude and width depends on their initial values and the parameters of the random structuring. Acting as a dispersive medium, a randomly structured plasma causes amplitude attenuation and width broadening of the fast wave pulses. After the passage of the main pulse, secondary propagating and standing fast waves appear. Width evolution of both linear and nonlinear pulses can be well approximated by linear functions; however, narrow pulses may have zero or negative broadening. This arises because narrow pulses are prone to splitting, while broad pulses usually deviate less from their initial Gaussian shape and form ripple structures on top of the main pulse. Linear pulses decay at an almost constant rate, while nonlinear pulses decay exponentially. A pulse interacts most efficiently with a random medium with a correlation length of about half of the initial pulse width. This detailed model of fast wave pulses propagating in highly structured media substantiates the interpretation of EIT waves as fast magnetoacoustic waves. Evolution of a fast pulse provides us with a novel method to diagnose the sub-resolution filamentation of the solar atmosphere

  3. Hybrid Pulsed Nd:YAG Laser

    Science.gov (United States)

    Miller, Sawyer; Trujillo, Skyler; Fort Lewis College Laser Group Team

    This work concerns the novel design of an inexpensive pulsed Nd:YAG laser, consisting of a hybrid Kerr Mode Lock (KLM) and Q-switch pulse. The two pulse generation systems work independently, non simultaneously of each other, thus generating the ability for the user to easily switch between ultra-short pulse widths or large energy density pulses. Traditionally, SF57 glass has been used as the Kerr medium. In this work, novel Kerr mode-locking mediums are being investigated including: tellurite compound glass (TeO2), carbon disulfide (CS2), and chalcogenide glass. These materials have a nonlinear index of refraction orders of magnitude,(n2), larger than SF57 glass. The Q-switched pulse will utilize a Pockels cell. As the two pulse generation systems cannot be operated simultaneously, the Pockels cell and Kerr medium are attached to kinematic mounts, allowing for quick interchange between systems. Pulse widths and repetition rates will vary between the two systems. A goal of 100 picosecond pulse widths are desired for the mode-locked system. A goal of 10 nanosecond pulse widths are desired for the Q-switch system, with a desired repetition rate of 50 Hz. As designed, the laser will be useful in imaging applications.

  4. Effect of initial chirp on near-infrared supercontinuum generation by a nanosecond pulse in a nonlinear fiber amplifier

    International Nuclear Information System (INIS)

    Song Rui; Hou Jing; Wang Ze-Feng; Lu Qi-Sheng; Xiao Rui

    2013-01-01

    Theoretical and experimental research on the effect of initial chirp on near-infrared supercontinuum generation by a nanosecond pulse in a nonlinear fiber amplifier is carried out. The complex Ginzburg—Landau equation is used to simulate the propagation of the pulse in the fiber amplifier and the results show that pulses with negative initial chirp produce the widest supercontinuum and pulses with positive initial chirp produce the narrowest supercontinuum when the central wavelength of the pump lies in the normal dispersion region of the gain fiber. A self-made line width narrowing system is utilized to control the initial chirp of the nanosecond pump pulse and a four-stage master oscillator power amplifier configuration is adopted to produce a high power near-infrared suppercontinuum. The experimental results are in good agreement with simulations which can provide some guidance on further optimization of the system in future work. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  5. An investigation of pulsed phase thermography for detection of disbonds in HIP-bonded beryllium tiles in ITER normal heat flux first wall (NHF FW) components

    Energy Technology Data Exchange (ETDEWEB)

    Bushell, J., E-mail: joe.bushell@amec.com [AMEC Foster Wheeler, Booths Hall, Chelford Road, Knutsford, Cheshire WA16 8QZ, England (United Kingdom); Sherlock, P. [AMEC Foster Wheeler, Booths Hall, Chelford Road, Knutsford, Cheshire WA16 8QZ, England (United Kingdom); Mummery, P. [School of Mechanical, Aerospace and Civil Engineering, University of Manchester, England (United Kingdom); Bellin, B.; Zacchia, F. [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, Barcelona (Spain)

    2015-10-15

    Highlights: • Pulsed phase thermography was trialled on Be-tiled plasma facing components. • Two components, one with known disbonds, one intact, were inspected and compared. • Finite element analysis was used to verify experimental observations. • PPT successfully detected disbonds in the failed component. • Good agreement found with ultrasonic test, though defect geometry was uncertain. - Abstract: Pulsed phase thermography (PPT) is a non destructive examination (NDE) technique, traditionally used in the Aerospace Industry for inspection of composite structures, which combines characteristics and benefits of flash thermography and lock-in thermography into a single, rapid inspection technique. The aim of this work was to evaluate the effectiveness of PPT as a means of inspection for the bond between the beryllium (Be) tiles and the copper alloy (CuCrZr) heatsink of the ITER NHF FW components. This is a critical area dictating the functional integrity of these components, as single tile detachment in service could result in cascade failure. PPT has advantages over existing thermography techniques using heated water which stress the component, and the non-invasive, non-contact nature presents advantages over existing ultrasonic methods. The rapid and non-contact nature of PPT also gives potential for in-service inspections as well as a quality measure for as-manufactured components. The technique has been appraised via experimental trials using ITER first wall mockups with pre-existing disbonds confirmed via ultrasonic tests, partnered with finite element simulations to verify experimental observations. This paper will present the results of the investigation.

  6. An investigation of pulsed phase thermography for detection of disbonds in HIP-bonded beryllium tiles in ITER normal heat flux first wall (NHF FW) components

    International Nuclear Information System (INIS)

    Bushell, J.; Sherlock, P.; Mummery, P.; Bellin, B.; Zacchia, F.

    2015-01-01

    Highlights: • Pulsed phase thermography was trialled on Be-tiled plasma facing components. • Two components, one with known disbonds, one intact, were inspected and compared. • Finite element analysis was used to verify experimental observations. • PPT successfully detected disbonds in the failed component. • Good agreement found with ultrasonic test, though defect geometry was uncertain. - Abstract: Pulsed phase thermography (PPT) is a non destructive examination (NDE) technique, traditionally used in the Aerospace Industry for inspection of composite structures, which combines characteristics and benefits of flash thermography and lock-in thermography into a single, rapid inspection technique. The aim of this work was to evaluate the effectiveness of PPT as a means of inspection for the bond between the beryllium (Be) tiles and the copper alloy (CuCrZr) heatsink of the ITER NHF FW components. This is a critical area dictating the functional integrity of these components, as single tile detachment in service could result in cascade failure. PPT has advantages over existing thermography techniques using heated water which stress the component, and the non-invasive, non-contact nature presents advantages over existing ultrasonic methods. The rapid and non-contact nature of PPT also gives potential for in-service inspections as well as a quality measure for as-manufactured components. The technique has been appraised via experimental trials using ITER first wall mockups with pre-existing disbonds confirmed via ultrasonic tests, partnered with finite element simulations to verify experimental observations. This paper will present the results of the investigation.

  7. Producing High Intense Attosecond Pulse Train by Interaction of Three-Color Pulse and Overdense Plasma

    Science.gov (United States)

    Salehi, M.; Mirzanejad, S.

    2017-05-01

    Amplifying the attosecond pulse by the chirp pulse amplification method is impossible. Furthermore, the intensity of attosecond pulse is low in the interaction of laser pulse and underdense plasma. This motivates us to propose using a multi-color pulse to produce the high intense attosecond pulse. In the present study, the relativistic interaction of a three-color linearly-polarized laser-pulse with highly overdense plasma is studied. We show that the combination of {{ω }}1, {{ω }}2 and {{ω }}3 frequencies decreases the instance full width at half maximum reflected attosecond pulse train from the overdense plasma surface. Moreover, we show that the three-color pulse increases the intensity of generated harmonics, which is explained by the relativistic oscillating mirror model. The obtained results demonstrate that if the three-color laser pulse interacts with overdense plasma, it will enhance two orders of magnitude of intensity of ultra short attosecond pulses in comparison with monochromatic pulse.

  8. MRI of normal pancreas : comparison of T2-weighted pulse sequences using turbo spin echo, turbo spin echo with fat suppression, HASTE and HASTE with fat suppression

    International Nuclear Information System (INIS)

    Lee, Kyoung Ho; Kim, Tae Kyoung; Jang, Hyun Jung; Kim, Young Hoon; Han, Sang Wook; Han, Joon Koo; Choi, Byung Ihn

    1998-01-01

    To compare various breath-hold T2 weighted sequences in imaging normal pancreas with a phased-array coil. HASTE showed higher SD/N than TSE or FS-HASTE (p<0.01). TSE was superior to TSE in the delineation of pancreatic duct (p<0.001). TSE showed more artifacts than FS-TSE (p<0.001): HASTE and FS-HASTE showed no artifact. TSE is better than HASTE for the delineation of pancreatic margin but HASTE shows less artifacts and a more conspicuous pancreatic duct. Fat suppression decreases artifacts but makes the pancreatic margin indistinct. (author). 19 refs., 1 tab., 2 figs

  9. Constant Width Planar Computation Characterizes ACC0

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Arnsfelt

    2006-01-01

    We obtain a characterization of ACC0 in terms of a natural class of constant width circuits, namely in terms of constant width polynomial size planar circuits. This is shown via a characterization of the class of acyclic digraphs which can be embedded on a cylinder surface in such a way that all...

  10. Palindromic widths of nilpotent and wreath products

    Indian Academy of Sciences (India)

    Palindromic width; commutator width; wreath products; nilpotent product. 2000 Mathematics ... An algorithm of the computation of the commutator length in free non-abelian .... It is clear that A(1)B = A × B is the direct sum. Let us list some ...

  11. A comparison of brief pulse and ultrabrief pulse electroconvulsive stimulation on rodent brain and behaviour.

    LENUS (Irish Health Repository)

    O'Donovan, Sinead

    2012-04-27

    Brief pulse electroconvulsive therapy (BP ECT; pulse width 0.5-1.5ms) is a very effective treatment for severe depression but is associated with cognitive side-effects. It has been proposed that ultrabrief pulse (UBP; pulse width 0.25-0.30ms) ECT may be as effective as BP ECT but have less cognitive effects because it is a more physiological form of neuronal stimulation. To investigate this further, we treated normal rats with a 10 session course of either BP (0.5ms), UBP (0.3ms), or sham electroconvulsive stimulation (ECS) and measured antidepressant-related changes in dentate gyrus cell proliferation and hippocampal BDNF protein levels as well as hippocampal-dependant spatial reference memory using the water plus maze and immobility time on the forced swim test. Both BP and UBP ECS induced very similar types of motor seizures. However, BP ECS but not UBP ECS treatment led to a significant, near 3-fold, increase in cell proliferation (p=0.026) and BDNF levels (p=0.01). In the forced swim test, only BP ECS treated animals had a significantly lower immobility time (p=0.046). There was a trend for similarly reduced hippocampal-dependent memory function in both BP and UBP groups but overall there was not a significant difference between treatment and control animals when tested 10 days after completing allocated treatment. These findings show that, even though both forms of ECS elicited similar motor seizures, UBP ECS was less efficient than BP ECS in inducing antidepressant-related molecular, cellular and behavioural changes.

  12. TEMPORAL EVOLUTION OF THE VELA PULSAR’S PULSE PROFILE

    Energy Technology Data Exchange (ETDEWEB)

    Palfreyman, J. L.; Dickey, J. M.; Ellingsen, S. P.; Jones, I. R. [Department of Physical Sciences, University of Tasmania, Private Bag 37, Hobart, Tasmania 7001 (Australia); Hotan, A. W., E-mail: jim77742@gmail.com [CSIRO Astronomy and Space Science, 26 Dick Perry Avenue, Technology Park, Kensington WA 6151 (Australia)

    2016-03-20

    The mechanisms of emission and changes in rotation frequency (“glitching”) of the Vela pulsar (J0835−4510) are not well understood. Further insight into these mechanisms can be achieved by long-term studies of integrated pulse width, timing residuals, and bright-pulse rates. We have undertaken an intensive observing campaign of Vela and collected over 6000 hr of single-pulse data. The data shows that the pulse width changes with time, including marked jumps in width after micro-glitches (frequency changes). The abundance of bright pulses also changes after some micro-glitches, but not all. The secular changes in pulse width have three possible cyclic periods that match with X-ray periodicities of a helical jet that are interpreted as free precession.

  13. Pulse Generator

    Science.gov (United States)

    Greer, Lawrence (Inventor)

    2017-01-01

    An apparatus and a computer-implemented method for generating pulses synchronized to a rising edge of a tachometer signal from rotating machinery are disclosed. For example, in one embodiment, a pulse state machine may be configured to generate a plurality of pulses, and a period state machine may be configured to determine a period for each of the plurality of pulses.

  14. Custom pulse generator for RPC testing

    International Nuclear Information System (INIS)

    Gil, A.; Castro, E.; Diaz, J.; Fonte, P.; Garzon, J.A.; Montes, N.; Zapata, M.

    2009-01-01

    We present a pulse generator able to generate pulses statistically similar to the ones produced by RPC cells. The device generates up to four arrays of fast and narrow random-like pulses. Polarity, maximum amplitudes, widths and pulse rate in each channel may be modified independently in order to simulate different RPC setups and environments. This portable and cost-effective pulse generator is a versatile instrument for testing FE-Electronics and different real detector features related with the signal propagation inside the detector. It has been developed in the framework of the ESTRELA project of the HADES experiment at GSI.

  15. A quantitative analysis of transtensional margin width

    Science.gov (United States)

    Jeanniot, Ludovic; Buiter, Susanne J. H.

    2018-06-01

    Continental rifted margins show variations between a few hundred to almost a thousand kilometres in their conjugated widths from the relatively undisturbed continent to the oceanic crust. Analogue and numerical modelling results suggest that the conjugated width of rifted margins may have a relationship to their obliquity of divergence, with narrower margins occurring for higher obliquity. We here test this prediction by analysing the obliquity and rift width for 26 segments of transtensional conjugate rifted margins in the Atlantic and Indian Oceans. We use the plate reconstruction software GPlates (http://www.gplates.org) for different plate rotation models to estimate the direction and magnitude of rifting from the initial phases of continental rifting until breakup. Our rift width corresponds to the distance between the onshore maximum topography and the last identified continental crust. We find a weak positive correlation between the obliquity of rifting and rift width. Highly oblique margins are narrower than orthogonal margins, as expected from analogue and numerical models. We find no relationships between rift obliquities and rift duration nor the presence or absence of Large Igneous Provinces (LIPs).

  16. The pulsed amplitude unit for the SLC

    International Nuclear Information System (INIS)

    Rolfe, J.; Browne, M.J.; Jobe, R.K.

    1987-02-01

    There is a recurring requirement in the SLC for the control of devices such as magnets, phase shifters, and attenuators on a beam-by-beam basis. The Pulsed Amplitude Unit (PAU) is a single width CAMAC module developed for this purpose. It provides digitally programmed analog output voltages on a beam-by-beam basis. Up to 32 preprogrammed values of output voltage are available from the single analog output of the module, and any of these values can be associated with any of the 256 possible SLC beam definitions. A 12-bit Analog-to-Digital Converter (ADC) digitizes an analog input signal at the appropriate beam time and stores it in a buffer memory. This feature is normally used to monitor the response of the device being controlled by the PAU at each beam time. Initial application of the PAU is a part of the system that controls the output of Klystrons in the SLC. The PAU combines several different functions in a single module. In order to accommodate these functions in a single width CAMAC module, field programmed logic is used extensively. Field Programmable Logic Arrays, Programmed Array Logic, and a Field Programmable Logic Sequencer are employed

  17. The pulsed amplitude unit for the SLC

    International Nuclear Information System (INIS)

    Rolfe, J.; Browne, M.J.; Jobe, R.K.

    1987-01-01

    There is a recurring requirement in the SLC for the control of devices such as magnets, phase shifters, and attenuators on a beam-by-beam basis. The Pulsed Amplitude Unit (PAU) is a single width CAMAC module developed for this purpose. It provides digitally programmed analog output voltages on a beam-by-beam basis. Up to 32 preprogrammed values of output voltage are available from the single analog output of the module, and any of these values can be associated with any of the 256 possible SLC beam definitions. A 12-bit Analog-to-Digital converter (ADC) digitizes an analog input signal at the appropriate beam time and stores it in a buffer memory. This feature is normally used to monitor the response of the device being controlled by the PAU at each beam time. Initial application of the PAU at is as part of the system that controls the output of Klystorns in the SLC. The PAU combines several different functions in a single module. In order to accommodate these functions in a single width CAMAC module, field programmed logic is used extensively. Field Programmable Logic Arrays, Programmed Array Logic, and a Field Programmable Logic Sequencer are employed

  18. The decay width of stringy hadrons

    Directory of Open Access Journals (Sweden)

    Jacob Sonnenschein

    2018-02-01

    We fit the theoretical decay width to experimental data for mesons on the trajectories of ρ, ω, π, η, K⁎, ϕ, D, and Ds⁎, and of the baryons N, Δ, Λ, and Σ. We examine both the linearity in L and the exponential suppression factor. The linearity was found to agree with the data well for mesons but less for baryons. The extracted coefficient for mesons A=0.095±0.015 is indeed quite universal. The exponential suppression was applied to both strong and radiative decays. We discuss the relation with string fragmentation and jet formation. We extract the quark–diquark structure of baryons from their decays. A stringy mechanism for Zweig suppressed decays of quarkonia is proposed and is shown to reproduce the decay width of ϒ states. The dependence of the width on spin and flavor symmetry is discussed. We further apply this model to the decays of glueballs and exotic hadrons.

  19. The decay width of stringy hadrons

    Science.gov (United States)

    Sonnenschein, Jacob; Weissman, Dorin

    2018-02-01

    In this paper we further develop a string model of hadrons by computing their strong decay widths and comparing them to experiment. The main decay mechanism is that of a string splitting into two strings. The corresponding total decay width behaves as Γ = π/2 ATL where T and L are the tension and length of the string and A is a dimensionless universal constant. We show that this result holds for a bosonic string not only in the critical dimension. The partial width of a given decay mode is given by Γi / Γ =Φi exp ⁡ (- 2 πCmsep2 / T) where Φi is a phase space factor, msep is the mass of the "quark" and "antiquark" created at the splitting point, and C is a dimensionless coefficient close to unity. Based on the spectra of hadrons we observe that their (modified) Regge trajectories are characterized by a negative intercept. This implies a repulsive Casimir force that gives the string a "zero point length". We fit the theoretical decay width to experimental data for mesons on the trajectories of ρ, ω, π, η, K*, ϕ, D, and Ds*, and of the baryons N, Δ, Λ, and Σ. We examine both the linearity in L and the exponential suppression factor. The linearity was found to agree with the data well for mesons but less for baryons. The extracted coefficient for mesons A = 0.095 ± 0.015 is indeed quite universal. The exponential suppression was applied to both strong and radiative decays. We discuss the relation with string fragmentation and jet formation. We extract the quark-diquark structure of baryons from their decays. A stringy mechanism for Zweig suppressed decays of quarkonia is proposed and is shown to reproduce the decay width of ϒ states. The dependence of the width on spin and flavor symmetry is discussed. We further apply this model to the decays of glueballs and exotic hadrons.

  20. Effective spectrum width of the synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V. G., E-mail: bagrov@phys.tsu.ru [Department of Physics, Tomsk State University, Tomsk (Russian Federation); Institute of High Current Electronics, SB RAS, Tomsk (Russian Federation); Gitman, D. M., E-mail: gitman@if.usp.br [Department of Physics, Tomsk State University, Tomsk (Russian Federation); Institute of Physics, University of São Paulo, São Paulo (Brazil); P.N.Lebedev Physical Institute, Moscow (Russian Federation); Levin, A. D., E-mail: alevin@if.usp.br [Institute of Physics, University of São Paulo, São Paulo (Brazil); Loginov, A. S.; Saprykin, A. D. [Department of Physics, Tomsk State University, Tomsk (Russian Federation)

    2015-11-25

    For an exact quantitative description of spectral properties of synchrotron radiation (SR), the concept of effective width of the spectrum is introduced. In the most interesting case, which corresponds to the ultrarelativistic limit of SR, the effective width of the spectrum is calculated for the polarization components, and new physically important quantitative information on the structure of spectral distributions is obtained. For the first time, the spectral distribution for the circular polarization component of the SR for the upper half-space is obtained within classical theory.

  1. Effective spectrum width of the synchrotron radiation

    International Nuclear Information System (INIS)

    Bagrov, V. G.; Gitman, D. M.; Levin, A. D.; Loginov, A. S.; Saprykin, A. D.

    2015-01-01

    For an exact quantitative description of spectral properties of synchrotron radiation (SR), the concept of effective width of the spectrum is introduced. In the most interesting case, which corresponds to the ultrarelativistic limit of SR, the effective width of the spectrum is calculated for the polarization components, and new physically important quantitative information on the structure of spectral distributions is obtained. For the first time, the spectral distribution for the circular polarization component of the SR for the upper half-space is obtained within classical theory

  2. Effective spectrum width of the synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V.G. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); SB RAS, Institute of High Current Electronics, Tomsk (Russian Federation); Gitman, D.M. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); University of Sao Paulo, Institute of Physics, Sao Paulo (Brazil); P.N. Lebedev Physical Institute, Moscow (Russian Federation); Levin, A.D. [University of Sao Paulo, Institute of Physics, Sao Paulo (Brazil); Loginov, A.S.; Saprykin, A.D. [Tomsk State University, Department of Physics, Tomsk (Russian Federation)

    2015-11-15

    For an exact quantitative description of spectral properties of synchrotron radiation (SR), the concept of effective width of the spectrum is introduced. In the most interesting case, which corresponds to the ultrarelativistic limit of SR, the effective width of the spectrum is calculated for the polarization components, and new physically important quantitative information on the structure of spectral distributions is obtained. For the first time, the spectral distribution for the circular polarization component of the SR for the upper half-space is obtained within classical theory. (orig.)

  3. Temperature dependence of giant dipole resonance width

    International Nuclear Information System (INIS)

    Vdovin, A.I.; Storozhenko, A.N.

    2005-01-01

    The quasiparticle-phonon nuclear model extended to finite temperature within the framework of the thermo field dynamics is applied to calculate a temperature dependence of the spreading width Γ d own of a giant dipole resonance. Numerical calculations are made for 12S n and 208 Pb nuclei. It is found that the width Γ d own increases with T. The reason of this effect is discussed as well as a relation of the present approach to other ones existing in the literature

  4. Line width of Josephson flux flow oscillators

    DEFF Research Database (Denmark)

    Koshelets, V.P.; Dmitriev, P.N.; Sobolev, A.S.

    2002-01-01

    to be proven before one initiates real FFO applications. To achieve this goal a comprehensive set of line width measurements of the FFO operating in different regimes has been performed. FFOs with tapered shape have been successfully implemented in order to avoid the superfine resonant structure with voltage...... spacing of about 20 nV and extremely low differential resistance, recently observed in the IVC of the standard rectangular geometry. The obtained results have been compared with existing theories and FFO models in order to understand and possibly eliminate excess noise in the FFO. The intrinsic line width...

  5. RF Pulsed Heating

    Energy Technology Data Exchange (ETDEWEB)

    Pritzkau, David P.

    2002-01-03

    RF pulsed heating is a process by which a metal is heated from magnetic fields on its surface due to high-power pulsed RF. When the thermal stresses induced are larger than the elastic limit, microcracks and surface roughening will occur due to cyclic fatigue. Pulsed heating limits the maximum magnetic field on the surface and through it the maximum achievable accelerating gradient in a normal conducting accelerator structure. An experiment using circularly cylindrical cavities operating in the TE{sub 011} mode at a resonant frequency of 11.424 GHz is designed to study pulsed heating on OFE copper, a material commonly used in normal conducting accelerator structures. The high-power pulsed RF is supplied by an X-band klystron capable of outputting 50 MW, 1.5 {micro}s pulses. The test pieces of the cavity are designed to be removable to allow testing of different materials with different surface preparations. A diagnostic tool is developed to measure the temperature rise in the cavity utilizing the dynamic Q change of the resonant mode due to heating. The diagnostic consists of simultaneously exciting a TE{sub 012} mode to steady-state in the cavity at 18 GHz and measuring the change in reflected power as the cavity is heated from high-power pulsed RF. Two experimental runs were completed. One run was executed at a calculated temperature rise of 120 K for 56 x 10{sup 6} pulses. The second run was executed at a calculated temperature rise of 82 K for 86 x 10{sup 6} pulses. Scanning electron microscope pictures show extensive damage occurring in the region of maximum temperature rise on the surface of the test pieces.

  6. Progressive changes in arch width from primary to early mixed dentition period: A longitudinal study

    OpenAIRE

    S Sangwan; H S Chawla; A Goyal; K Gauba; U Mohanty

    2011-01-01

    Objective: The present study was conducted to evaluate, on a longitudinal basis, the changes in intercanine and intermolar widths form the primary to the early mixed dentition periods. Materials and Methods: A total of 38 children aged 4-5 years, with normal occlusion without any proximal caries or any dental anomalies, were selected. The impressions were recorded and casts were prepared. Intercanine and intermolar widths were measured on these dental casts with the help of a digital vernier ...

  7. Ultrashort-pulse measurement using noninstantaneous nonlinearities: Raman effects in frequency-resolved optical gating

    International Nuclear Information System (INIS)

    DeLong, K.W.; Ladera, C.L.; Trebino, R.; Kohler, B.; Wilson, K.R.

    1995-01-01

    Ultrashort-pulse-characterization techniques generally require instantaneously responding media. We show that this is not the case for frequency-resolved optical gating (FROG). We include, as an example, the noninstantaneous Raman response of fused silica, which can cause errors in the retrieved pulse width of as much as 8% for a 25-fs pulse in polarization-gate FROG. We present a modified pulse-retrieval algorithm that deconvolves such slow effects and use it to retrieve pulses of any width. In experiments with 45-fs pulses this algorithm achieved better convergence and yielded a shorter pulse than previous FROG algorithms

  8. Steering population transfer of the Na2 molecule by an ultrashort pulse train

    Science.gov (United States)

    Niu, Dong-Hua; Wang, Shuo; Zhan, Wei-Shen; Tao, Hong-Cai; Wang, Si-Qi

    2018-05-01

    We theoretically investigate the complete population transfer among quantum states of the Na2 molecule using ultrashort pulse trains using the time-dependent wave packet method. The population accumulation of the target state can be steered by controlling the laser parameters, such as the variable pulse pairs, the different pulse widths, the time delays and the repetition period between two contiguous pulses; in particular, the pulse pairs and the pulse widths have a great effect on the population transfer. The calculations show that the ultrashort pulse train is a feasible solution, which can steer the population transfer from the initial state to the target state efficiently with lower peak intensities.

  9. DURATION LIMIT OF LASER PULSES EMITTED FROM A Ce-DOPED CRYSTAL SHORT CAVITY

    Directory of Open Access Journals (Sweden)

    Le Hoang Hai

    2017-11-01

    Full Text Available Based on the rate equation set for broadband cavities, the dependence of pulse duration on cavity and pumping parameters is analyzed. The cavity uses a Ce-doped crystal as a gain medium. Computation results show the variation of the pulse width with the change of cavity length, mirror reflectivity, pumping energy and pumping pulse duration. A significant influence of multiple-pulse operation in limiting pulse duration is realized and a pulse-width of the order 200 ps is found to be the limit for the direct generation of ultraviolet single picosecond pulses from a Ce:LLF short cavity.

  10. Radiative width of molecular-cluster states

    International Nuclear Information System (INIS)

    Alhassid, Y.; Gai, M.; Bertsch, G.F.

    1982-01-01

    Molecular states are characterized by enhanced electromagnetic deexcitations of many different multipolarities. The expected enhancement of E1, E2, and E3 transitions is examined by deriving molecular sum rules for radiative deexcitation widths and via a dimensionality approach. The enhancement of the E1 transitions is the most striking

  11. Bounding the Higgs boson width through interferometry.

    Science.gov (United States)

    Dixon, Lance J; Li, Ye

    2013-09-13

    We study the change in the diphoton-invariant-mass distribution for Higgs boson decays to two photons, due to interference between the Higgs resonance in gluon fusion and the continuum background amplitude for gg→γγ. Previously, the apparent Higgs mass was found to shift by around 100 MeV in the standard model in the leading-order approximation, which may potentially be experimentally observable. We compute the next-to-leading-order QCD corrections to the apparent mass shift, which reduce it by about 40%. The apparent mass shift may provide a way to measure, or at least bound, the Higgs boson width at the Large Hadron Collider through "interferometry." We investigate how the shift depends on the Higgs width, in a model that maintains constant Higgs boson signal yields. At Higgs widths above 30 MeV, the mass shift is over 200 MeV and increases with the square root of the width. The apparent mass shift could be measured by comparing with the ZZ* channel, where the shift is much smaller. It might be possible to measure the shift more accurately by exploiting its strong dependence on the Higgs transverse momentum.

  12. Practical algorithms for linear boolean-width

    NARCIS (Netherlands)

    ten Brinke, C.B.; van Houten, F.J.P.; Bodlaender, H.L.

    2015-01-01

    In this paper, we give a number of new exact algorithms and heuristics to compute linear boolean decompositions, and experimentally evaluate these algorithms. The experimental evaluation shows that significant improvements can be made with respect to running time without increasing the width of the

  13. Practical algorithms for linear Boolean-width

    NARCIS (Netherlands)

    ten Brinke, C.B.; van Houten, F.J.P.; Bodlaender, H.L.

    2015-01-01

    In this paper, we give a number of new exact algorithms and heuristics to compute linear boolean decompositions, and experimentally evaluate these algorithms. The experimental evaluation shows that significant improvements can be made with respect to running time without increasing the width of the

  14. Disruptive tension under normalized atmospheric pulse and residual tension on lightning arresters power systems: statistical methods application. Practical results and comments; Ensaios de tensao disruptiva sob impulso atmosferico normalizado e tensao residual em para-raios para sistemas de potencia: a aplicacao de metodos estatisticos. Comentarios e resultados praticos

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, M.L.B. [ELETRONORTE, Brasilia (Brazil); Oliveira, A.L. [Eletricidade da Sao Paulo S.A. (ELETROPAULO), Sao Paulo, SP (Brazil)

    1991-12-31

    The necessity of complementary assays of disruptive tension under normalized atmospheric pulses and residual tension on lightning arresters, as well as the adequate use of a statistical treatment of its results are commented. Some statistical methods and its applicability on lightning arresters characteristics surveys, and its quality control are proposed 8 refs., 5 figs., 3 tabs.

  15. Multi-channel normal speed gated integrator in the measurement of the laser scattering light energy

    International Nuclear Information System (INIS)

    Yang Dong; Yu Xiaoqi; Hu Yuanfeng

    2005-01-01

    With the method of integration in a limited time, a Multi-channel normal speed gated integrator based on VXI system has been developed for measuring the signals with changeable pulse width in laser scattering light experiment. It has been tested with signal sources in ICF experiment. In tests, the integral nonlinearity between the integral results of the gated integrator and that of an oscilloscope is less than 1%. In the ICF experiments the maximum error between the integral results of the gated integrator and that of oscilloscope is less than 3% of the full scale range of the gated integrator. (authors)

  16. Pulsed-linac synchronization using an embedded micro-controller

    International Nuclear Information System (INIS)

    Craig, S.R.; Alexander, S.B.; West, R.J.; Simpson, M.P.

    1992-01-01

    A Master Timing Generator (MTG) was developed using a single Motorola MC68332 embedded micro-controller. The MTG produces electrical synchronization pulses that coordinate the action of all pulsed subsystems and the acquisition of pulsed data. Pulse width and delay-offset of each of the 13 output channels can be changed on-line. The MTG is interfaced with a GE Series-Six Programmable Logic Controller (PLC), which coordinates overall control of the IMPELA linac. Serial communications are used between the PLC and the MTG. The PLC needs only to transmit data to define the pulse repetition rate, the beam pulse width, and the subsystems that should be active. The MTG determines the widths and relative delays required to achieve the requested beam pulse-width. Changes in width and repetition rate are effected using a smooth ramp to avoid power-demand transients. All MTG timing requirements are met with the current implementation, having the following characteristics: 1 Hz ≤ repetition rate ≤ 500 Hz with ±1% resolution, 12 μs ≤ width ≤ 1000 μs in 1 μs steps, and a delay-offset range of 4.5 ms in 1 μs steps. (Author) (4 figs., 5 refs.)

  17. Pulsed inductive HF laser

    Energy Technology Data Exchange (ETDEWEB)

    Razhev, A M; Kargapol' tsev, E S [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Churkin, D S; Demchuk, S V [Novosibirsk State University, Novosibirsk (Russian Federation)

    2016-03-31

    We report the results of experimentally investigated dependences of temporal, spectral and spatial characteristics of an inductive HF-laser generation on the pump conditions. Gas mixtures H{sub 2} – F{sub 2}(NF{sub 3} or SF6{sub 6}) and He(Ne) – H{sub 2} – F{sub 2}(NF{sub 3} or SF{sub 6}) were used as active media. The FWHM pulse duration reached 0.42 μs. This value corresponded to a pulsed power of 45 kW. For the first time, the emission spectrum of an inductive HF laser was investigated, which consisted of seven groups of bands with centres around the wavelengths of 2732, 2736, 2739, 2835, 2837, 2893 and 2913 nm. The cross section profile of the laser beam was a ring with a diameter of about 20 mm and width of about 5 mm. Parameters of laser operation in the repetitively pulsed regime were sufficiently stable. The amplitude instability of light pulses was no greater than 5% – 6%. (lasers)

  18. Effects of pulsed electrical field processing on microbial survival, quality change and nutritional characteristics of blueberries

    Science.gov (United States)

    Whole fresh blueberries were treated using a parallel pulsed electric field (PEF) treatment chamber and a sanitizer solution (60 ppm peracetic acid [PAA]) as PEF treatment medium with square wave bipolar pulses at 2 kV/cm electric field strength, 1us pulse width, and 100 pulses per second for 2, 4, ...

  19. Narrow widths of old and new resonances

    International Nuclear Information System (INIS)

    Pasupathy, J.

    1977-01-01

    A quantitative measure of the suppression factors involved in the pionic decays of mesons phi(1019) and f'(1514) as compared to their kaonic psi(3100) and psi(3700) decays are explained using the two different approaches, viz., the phenomenological S matrix approach and the field theoretical approach. The importance of the O-Z-I rule is brought out. The partial width GAMMA(phi → 3π) has been calculated using the dual model for the scattering kappa kappa(bar) → rhoπ. The effective coupling psi rho π is evaluated. The partial widths for psi → e + e - and psi → hadrons is calculated on a field theoretical approach. In conclusion, it appears that there are no serious objections to interpreting psi and psi' as cc - states. Most of their properties can be understood in a qualitative and in semi-quantitative way. (A.K.)

  20. Numerical simulation of distorted crystal Darwin width

    International Nuclear Information System (INIS)

    Wang Li; Xu Zhongmin; Wang Naxiu

    2012-01-01

    A new numerical simulation method according to distorted crystal optical theory was used to predict the direct-cooling crystal monochromator optical properties(crystal Darwin width) in this study. The finite element analysis software was used to calculate the deformed displacements of DCM crystal and to get the local reciprocal lattice vector of distorted crystal. The broadening of direct-cooling crystal Darwin width in meridional direction was estimated at 4.12 μrad. The result agrees well with the experimental data of 5 μrad, while it was 3.89 μrad by traditional calculation method of root mean square (RMS) of the slope error in the center line of footprint. The new method provides important theoretical support for designing and processing of monochromator crystal for synchrotron radiation beamline. (authors)

  1. Exotic meson decay widths using lattice QCD

    International Nuclear Information System (INIS)

    Cook, M. S.; Fiebig, H. R.

    2006-01-01

    A decay width calculation for a hybrid exotic meson h, with J PC =1 -+ , is presented for the channel h→πa 1 . This quenched lattice QCD simulation employs Luescher's finite box method. Operators coupling to the h and πa 1 states are used at various levels of smearing and fuzzing, and at four quark masses. Eigenvalues of the corresponding correlation matrices yield energy spectra that determine scattering phase shifts for a discrete set of relative πa 1 momenta. Although the phase shift data is sparse, fits to a Breit-Wigner model are attempted, resulting in a decay width of about 60 MeV when averaged over two lattice sizes having a lattice spacing of 0.07 fm

  2. Analysis of reduced widths and size

    International Nuclear Information System (INIS)

    Sharma, H.C.; Ram Raj; Nath, N.

    1977-01-01

    Recent data on S-wave neutron reduced widths for a large number of nuclei have been analysed nucleus-wise and the calculations for the degree of freedom of the associated (chi) 2 -distribution have been made using the Porter and Thomas procedure. It is noted that a number of nuclei can be fitted by a (chi) 2 -distribution with degree of freedom one, while there are few which are identified to follow a (chi) 2 -distribution with degree of freedom two and even more than two. The present analysis thus contradicts the usual presumption according to which the degree of freedom is taken to be always unity. An analytical attempt has also been made to ascertain the suitability of the data on reduced widths to be used for the analysis. These considerations are likely to modify the neutron cross-section evaluations. (author)

  3. Meson widths from string worldsheet instantons

    International Nuclear Information System (INIS)

    Faulkner, Thomas; Liu, Hong

    2009-01-01

    We show that open strings living on a D-brane which lies outside an AdS black hole can tunnel into the black hole through worldsheet instantons. These instantons have a simple interpretation in terms of thermal quarks in the dual Yang-Mills (YM) theory. As an application we calculate the width of a meson in a strongly coupled quark-gluon plasma which is described holographically as a massless mode on a D7 brane in AdS 5 xS 5 . While the width of the meson is zero to all orders in the 1/√(λ) expansion with λ the 't Hooft coupling, it receives non-perturbative contributions in 1/√(λ) from worldsheet instantons. We find that the width increases quadratically with momentum at large momentum and comment on potential phenomenological implications of this enhancement for heavy ion collisions. We also comment on how this non-perturbative effect has important consequences for the phase structure of the YM theory obtained in the classical gravity limit

  4. L-band pulsed klystron for the JHP

    International Nuclear Information System (INIS)

    Fukuda, S.; Takeuchi, Y.; Hisamatsu, H.; Anami, S.; Kihara, M.; Takahashi, A.

    1994-01-01

    An L-band high-power klystron for the JHP (6 MW output power and 600 μsec pulse width) was designed at KEK. High-power tests of the test diodes were performed up to a beam voltage of 140 kV, a pulse width of 600 μsec and a repetition rate of 50 pps. The capability to meet the specifications of the gun and the collector was confirmed. High-power tests of the rf window were also performed up to rf powers of 4 MW (600 μsec pulse width) and 5 MW (375 μsec pulse width). We obtained good results for an rf window using high-purity alumina (99.7%). The design considerations and manufacturing process are also described. Manufacturing a prototype tube has been completed and the tube is undergoing the high-power tests. (author)

  5. Width and partial widths of unstable particles in the light of the Nielsen identities

    International Nuclear Information System (INIS)

    Grassi, P.A.; Sirlin, A.; Kniehl, B.A.; Hamburg Univ.

    2001-09-01

    Fundamental properties of unstable particles, including mass, width, and partial widths, are examined on the basis of the Nielsen identities (NI) that describe the gauge dependence of Green functions. In particular, we prove that the pole residues and associated definitions of branching ratios and partial widths are gauge independent to all orders. A simpler, previously discussed definition of branching ratios and partial widths is found to be gauge independent through next-to-next-to-leading order. It is then explained how it may be modified in order to extend the gauge independence to all orders. We also show that the physical scattering amplitude is the most general combination of self-energy, vertex, and box contributions that is gauge independent for arbitrary s, discuss the analytical properties of the NI functions, and exhibit explicitly their one-loop expressions in the Z-γ sector of the Standard Model. (orig.)

  6. Width and partial widths of unstable particles in the light of the Nielsen identities

    International Nuclear Information System (INIS)

    Grassi, Pietro A.; Kniehl, Bernd A.; Sirlin, Alberto

    2002-01-01

    Fundamental properties of unstable particles, including mass, width, and partial widths, are examined on the basis of the Nielsen identities (NI) that describe the gauge dependence of Green functions. In particular, we prove that the pole residues and associated definitions of branching ratios and partial widths are gauge independent to all orders. A simpler, previously discussed definition of branching ratios and partial widths is found to be gauge independent through next-to-next-to-leading order. It is then explained how it may be modified in order to extend the gauge independence to all orders. We also show that the physical scattering amplitude is the most general combination of self-energy, vertex, and box contributions that is gauge independent for arbitrary s, discuss the analytical properties of the NI functions, and exhibit explicitly their one-loop expressions in the Z-γ sector of the standard model

  7. iPhone 4s photoplethysmography: which light color yields the most accurate heart rate and normalized pulse volume using the iPhysioMeter Application in the presence of motion artifact?

    Directory of Open Access Journals (Sweden)

    Kenta Matsumura

    Full Text Available Recent progress in information and communication technologies has made it possible to measure heart rate (HR and normalized pulse volume (NPV, which are important physiological indices, using only a smartphone. This has been achieved with reflection mode photoplethysmography (PPG, by using a smartphone's embedded flash as a light source and the camera as a light sensor. Despite its widespread use, the method of PPG is susceptible to motion artifacts as physical displacements influence photon propagation phenomena and, thereby, the effective optical path length. Further, it is known that the wavelength of light used for PPG influences the photon penetration depth and we therefore hypothesized that influences of motion artifact could be wavelength-dependant. To test this hypothesis, we made measurements in 12 healthy volunteers of HR and NPV derived from reflection mode plethysmograms recorded simultaneously at three different spectral regions (red, green and blue at the same physical location with a smartphone. We then assessed the accuracy of the HR and NPV measurements under the influence of motion artifacts. The analyses revealed that the accuracy of HR was acceptably high with all three wavelengths (all rs > 0.996, fixed biases: -0.12 to 0.10 beats per minute, proportional biases: r =  -0.29 to 0.03, but that of NPV was the best with green light (r = 0.791, fixed biases: -0.01 arbitrary units, proportional bias: r = 0.11. Moreover, the signal-to-noise ratio obtained with green and blue light PPG was higher than that of red light PPG. These findings suggest that green is the most suitable color for measuring HR and NPV from the reflection mode photoplethysmogram under motion artifact conditions. We conclude that the use of green light PPG could be of particular benefit in ambulatory monitoring where motion artifacts are a significant issue.

  8. Dose rate effect on micronuclei induction in human blood lymphocytes exposed to single pulse and multiple pulses of electrons.

    Science.gov (United States)

    Acharya, Santhosh; Bhat, N N; Joseph, Praveen; Sanjeev, Ganesh; Sreedevi, B; Narayana, Y

    2011-05-01

    The effects of single pulses and multiple pulses of 7 MV electrons on micronuclei (MN) induction in cytokinesis-blocked human peripheral blood lymphocytes (PBLs) were investigated over a wide range of dose rates per pulse (instantaneous dose rate). PBLs were exposed to graded doses of 2, 3, 4, 6, and 8 Gy of single electron pulses of varying pulse widths at different dose rates per pulse, ranging from 1 × 10(6) Gy s(-1) to 3.2 × 10(8) Gy s(-1). Different dose rates per pulse were achieved by changing the dose per electron pulse by adjusting the beam current and pulse width. MN yields per unit absorbed dose after irradiation with single electron pulses were compared with those of multiple pulses of electrons. A significant decrease in the MN yield with increasing dose rates per pulse was observed, when dose was delivered by a single electron pulse. However, no reduction in the MN yield was observed when dose was delivered by multiple pulses of electrons. The decrease in the yield at high dose rates per pulse suggests possible radical recombination, which leads to decreased biological damage. Cellular response to the presence of very large numbers of chromosomal breaks may also alter the damage.

  9. Influence of inhomogeneous broadening and deliberately introduced disorder on the width of the lasing spectrum of a quantum dot laser

    International Nuclear Information System (INIS)

    Korenev, V. V.; Savelyev, A. V.; Zhukov, A. E.; Omelchenko, A. V.; Maximov, M. V.

    2012-01-01

    Analytical expressions for the shape and width of the lasing spectra of a quantum-dot (QD) laser in the case of a small (in comparison with the spectrum width) homogeneous broadening of the QD energy levels have been obtained. It is shown that the dependence of the lasing spectrum width on the output power at room temperature is determined by two dimensionless parameters: the width of QD distribution over the optical-transition energy, normalized to temperature, and the ratio of the optical loss to the maximum gain. The optimal dimensions of the laser active region have been found to obtain a specified width of the emission spectrum at a minimum pump current. The possibility of using multilayer structures with QDs to increase the lasing spectrum’s width has been analyzed. It is shown that the use of several arrays of QDs with deliberately variable optical-transition energies leads to broadening of the lasing spectra; some numerical estimates are presented.

  10. The optimum choice of gate width for neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Croft, S., E-mail: crofts@ornl.gov [Safeguards and Security Technology (SST), Global Nuclear Security Technology Divisions, PO Box 2008, Building 5700, MS-6166, Oak Ridge, TN 37831-6166 (United States); Henzlova, D.; Favalli, A.; Hauck, D.K.; Santi, P.A. [Safeguards Science and Technology Group (NEN-1), Nuclear Engineering and Nonproliferation Division, MS-E540, Los Alamos, NM 87545 (United States)

    2014-11-11

    In the measurement field of international nuclear safeguards, passive neutron coincidence counting is used to quantify the spontaneous fission rate of certain special nuclear materials. The shift register autocorrelation analysis method is the most commonly used approach. However, the Feynman-Y technique, which is more commonly applied in reactor noise analysis, provides an alternative means to extract the correlation information from a pulse train. In this work we consider how to select the optimum gate width for each of these two time-correlation analysis techniques. The optimum is considered to be that which gives the lowest fractional precision on the net doublets rate. Our theoretical approach is approximate but is instructional in terms of revealing the key functional dependence. We show that in both cases the same performance figure of merit applies so that common design criteria apply to the neutron detector head. Our prediction is that near optimal results, suitable for most practical applications, can be obtained from both techniques using a common gate width setting. The estimated precision is also comparable in the two cases. The theoretical expressions are tested experimentally using {sup 252}Cf spontaneous fission sources measured in two thermal well counters representative of the type in common use by international inspectorates. Fast accidental sampling was the favored method of acquiring the Feynman-Y data. Our experimental study confirmed the basic functional dependences predicted although experimental results when available are preferred. With an appropriate gate setting Feynman-Y analysis provides an alternative to shift register analysis for safeguards applications which is opening up new avenues of data collection and data reduction to explore.

  11. OH Production Enhancement in Bubbling Pulsed Discharges

    Science.gov (United States)

    Lungu, Cristian P.; Porosnicu, Corneliu; Jepu, Ionut; Chiru, Petrica; Zaroschi, Valentin; Lungu, Ana M.; Saito, Nagahiro; Bratescu, Maria; Takai, Osamu; Velea, Theodor; Predica, Vasile

    2010-10-01

    The generation of active species, such as H2O2, O*, OH*, HO2*, O3, N2*, etc, produced in aqueous solutions by HV pulsed discharges was studied in order to find the most efficient way in waste water treatment taking into account that these species are almost stronger oxidizers than ozone. Plasma was generated inside gas bubbles formed by the argon, air and oxygen gas flow between the special designed electrodes. The pulse width and pulse frequency influence was studied in order to increase the efficiency of the OH active species formation. The produced active species were investigated by optical emission spectroscopy and correlated with electrical parameters of the discharges (frequency, pulse width, amplitude, and rise and decay time).

  12. OH Production Enhancement in Bubbling Pulsed Discharges

    International Nuclear Information System (INIS)

    Lungu, Cristian P.; Porosnicu, Corneliu; Jepu, Ionut; Chiru, Petrica; Zaroschi, Valentin; Lungu, Ana M.; Saito, Nagahiro; Bratescu, Maria; Takai, Osamu; Velea, Theodor; Predica, Vasile

    2010-01-01

    The generation of active species, such as H 2 O 2 , O * , OH*, HO 2 *, O 3 , N 2 * , etc, produced in aqueous solutions by HV pulsed discharges was studied in order to find the most efficient way in waste water treatment taking into account that these species are almost stronger oxidizers than ozone. Plasma was generated inside gas bubbles formed by the argon, air and oxygen gas flow between the special designed electrodes. The pulse width and pulse frequency influence was studied in order to increase the efficiency of the OH active species formation. The produced active species were investigated by optical emission spectroscopy and correlated with electrical parameters of the discharges (frequency, pulse width, amplitude, and rise and decay time).

  13. Universal pulse generator with a nanosecond fast responce

    International Nuclear Information System (INIS)

    Basiladze, S.G.; Nguen Kuang Min'.

    1977-01-01

    A pulse generator with nanosecond action is described; it is mainly designed for testing and tuning fast electronic devices operating with pulses in the N/1/M standard. The generator is principally based on integral circuits and has wide functional potentialities: it includes a main-pulse channel, a delayed-pulse channel, and an overall output, which sums up these pulses; in addition to the logic pulse outputs it includes a linear pulse output with an amplitude smoothly regulated in the range from 0.3 to 6.0 V; it can operate in the self-oscillation mode, in the pulse series formation mode, in the starting mode, and in the single-start mode. Two generators are placed in a double-width CAMAC cell. The generation frequency is from 3 Hz to 75 MHz, pulse duration from 8 to 320 ns, and pulse front duration 2 ns

  14. Generation of programmable temporal pulse shape and applications in micromachining

    Science.gov (United States)

    Peng, X.; Jordens, B.; Hooper, A.; Baird, B. W.; Ren, W.; Xu, L.; Sun, L.

    2009-02-01

    In this paper we presented a pulse shaping technique on regular solid-state lasers and the application in semiconductor micromachining. With a conventional Q-switched laser, all of the parameters can be adjusted over only limited ranges, especially the pulse width and pulse shape. However, some laser link processes using traditional laser pulses with pulse widths of a few nanoseconds to a few tens of nanoseconds tend to over-crater in thicker overlying passivation layers and thereby cause IC reliability problems. Use of a laser pulse with a special shape and a fast leading edge, such as tailored pulse, is one technique for controlling link processing. The pulse shaping technique is based on light-loop controlled optical modulation to shape conventional Q-switched solid-state lasers. One advantage of the pulse shaping technique is to provide a tailored pulse shape that can be programmed to have more than one amplitude value. Moreover, it has the capability of providing programmable tailored pulse shapes with discrete amplitude and time duration components. In addition, it provides fast rising and fall time of each pulse at fairly high repetition rate at 355nm with good beam quality. The regular-to-shaped efficiency is up to 50%. We conclude with a discussion of current results for laser processing of semiconductor memory link structures using programmable temporal pulse shapes. The processing experiments showed promising results with shaped pulse.

  15. Self-compression of intense short laser pulses in relativistic magnetized plasma

    Energy Technology Data Exchange (ETDEWEB)

    Olumi, M.; Maraghechi, B., E-mail: behrouz@aut.ac.ir [Department of Physics, Amirkabir University of Technology, Post code 15916-34311 Tehran (Iran, Islamic Republic of)

    2014-11-15

    The compression of a relativistic Gaussian laser pulse in a magnetized plasma is investigated. By considering relativistic nonlinearity and using non-linear Schrödinger equation with paraxial approximation, a second-order differential equation is obtained for the pulse width parameter (in time) to demonstrate the longitudinal pulse compression. The compression of laser pulse in a magnetized plasma can be observed by the numerical solution of the equation for the pulse width parameter. The effects of magnetic field and chirping are investigated. It is shown that in the presence of magnetic field and negative initial chirp, compression of pulse is significantly enhanced.

  16. Mode-field half-widths of Gaussian approximation for the fundamental mode of two kinds of optical waveguides

    International Nuclear Information System (INIS)

    Lian-Huang, Li; Fu-Yuan, Guo

    2009-01-01

    This paper analyzes the characteristic of matching efficiency between the fundamental mode of two kinds of optical waveguides and its Gaussian approximate field. Then, it presents a new method where the mode-field half-width of Gaussian approximation for the fundamental mode should be defined according to the maximal matching efficiency method. The relationship between the mode-field half-width of the Gaussian approximate field obtained from the maximal matching efficiency and normalized frequency is studied; furthermore, two formulas of mode-field half-widths as a function of normalized frequency are proposed

  17. Is biologic width of anterior and posterior teeth similar?

    Directory of Open Access Journals (Sweden)

    Amir Alireza Rasouli Ghahroudi

    2014-09-01

    Full Text Available The biologic width (BW includes attached epithelial cells and connective tissue attachment complex being very important in the periodontal health during prosthetic treatments as invading this zone can cause bone resorption and gingival recession. The present study investigated biologic width values in the normal periodontium in anterior and posterior teeth. 30 patients that referred from restorative department to periodontics department of Tehran University of medical sciences who need crown lengthening procedure on their teeth with no history of orthodontic, prosthodontic and periodontal treatment were randomly enrolled in this cross-sectional trial. Sulcus depths (SD as well as the distance between free gingival margin and the bone crest (FB of anterior and posterior teeth were measured by UNC-15 probe and compared. periodontium thickness was also assessed. The data were subjected to Student t test. Mean BW in the 43 anterior and 47 posterior teeth was measured and not significantly different (1.4651±0.39 mm vs. 1.6312±0.49 mm was observed; however, BW was significantly more in the teeth with thick periodontium compared to those with thin periodontium (1.703±0.5 vs. 1.408±0.35; P=0.002. BW not only is different in individuals but also could be dissimilar in different teeth and should be calculated independently prior to restorative treatments.

  18. Nuclear structure effects on alpha reduced widths

    International Nuclear Information System (INIS)

    Toth, K.S.; Ellis-Akovali, Y.A.; Kim, H.J.; McConnell, J.W.

    1987-01-01

    A review of α widths for s-wave transitions is presented together with a discussion of the following topics: (1) a new determination of the 218 Ra half-life and its relation to reflection asymmetry in nuclei near N = 130, (2) a measurement of the 194 Pb α-decay rate and the influence of the Z = 82 gap on neutron-deficient Pb nuclei, and (3) an up-date of α-decay-rate systematics for isotopes in the rare earth and medium-weight mass regions. 16 refs., 6 figs

  19. Statistical analysis of partial reduced width distributions

    International Nuclear Information System (INIS)

    Tran Quoc Thuong.

    1973-01-01

    The aim of this study was to develop rigorous methods for analysing experimental event distributions according to a law in chi 2 and to check if the number of degrees of freedom ν is compatible with the value 1 for the reduced neutron width distribution. Two statistical methods were used (the maximum-likelihood method and the method of moments); it was shown, in a few particular cases, that ν is compatible with 1. The difference between ν and 1, if it exists, should not exceed 3%. These results confirm the validity of the compound nucleus model [fr

  20. Simple method for calculating island widths

    International Nuclear Information System (INIS)

    Cary, J.R.; Hanson, J.D.; Carreras, B.A.; Lynch, V.E.

    1989-01-01

    A simple method for calculating magnetic island widths has been developed. This method uses only information obtained from integrating along the closed field line at the island center. Thus, this method is computationally less intensive than the usual method of producing surfaces of section of sufficient detail to locate and resolve the island separatrix. This method has been implemented numerically and used to analyze the buss work islands of ATF. In this case the method proves to be accurate to at least within 30%. 7 refs

  1. A system for long pulse REB generation

    International Nuclear Information System (INIS)

    Tsuzuki, Tetsuya; Hasegawa, Mitsuru; Narihara, Kazumichi; Tomita, Yukihiro; Kubo, Shin; Kobata, Tadasuke; Mohri, Akihiro.

    1987-02-01

    A high voltage pulse generator system producing intense relativistic electron beams (REB) (1.5 μs pulse width, 30 kA peak current, 1 MeV energy) was developed to the use of REB ring formation. The system consists of a Marx generator, a transmission line with plastics-water hybrid insulators and a magnetically insulated transmission line connected with a cathode. The system has been well operated more than twenty thousands shots without troubles. (author)

  2. Pulsed gas feed to the ion source

    International Nuclear Information System (INIS)

    Tanaka, Shigeru; Shibata, Takemasa

    1976-11-01

    Hydrogen gas feed to the ion source of a neutral beam injector for the JFT-2 tokamak has been pulsed by a set of gas reservoir, solenoid valve and variable leak. During the pulse width the flow rate is constant except for its initial overshoot. After detailed study of the temporal behaviour, the solenoid valve and variable leak were replaced with a piezo-electric valve, resulting in improvement of the rise and decay. (auth.)

  3. Determination by transfer reaction of alpha widths in fluorine for astrophysical interest

    International Nuclear Information System (INIS)

    Oliveira Santos, F. de

    1995-04-01

    The nucleosynthesis of fluorine is not known. Several astrophysical models predict the alpha radiative capture onto N 15 as the main fluorine production reaction. In the expression of the reaction rate, one parameter is missing: the alpha width of the resonance on the E = 4.377 MeV level in fluorine. A direct measurement is excluded due to the very low cross-section expected. We have determined this alpha width using a transfer reaction followed by analyses with FR-DWBA (Finite Range Distorted Wave Born Approximation) in a simple cluster alpha model. This experiment was carried out with a Li 7 beam with E = 28 MeV onto a N 15 gas target. The 16 first levels were studied. Spectroscopic factors were extracted for most of them. Alpha widths for unbound levels were determined. Many alpha width were compared with known values from direct reaction and the differences lie within the uncertainty range (factor 2). The alpha width for the E = 4.377 MeV level was determined (Γ α = 1.5*10 -15 MeV), its value is about 60 times weaker than the used value. The influence of our new rate was studied in AGB (Asymptotic Giant Branch) stars during thermal pulses. In this model the alteration is sensitive. (author)

  4. Compliance of the normal-sized aorta in adolescents with Marfan syndrome: comparison of MR measurements of aortic distensibility and pulse wave velocity; Compliance der morphologisch unauffaelligen Aorta bei Jugendlichen mit Marfan Syndrom: Vergleich von MR-Messungen der aortalen Dehnbarkeit und der Pulswellengeschwindigkeit

    Energy Technology Data Exchange (ETDEWEB)

    Eichhorn, J.G.; Ruediger, H.J.; Gorenflo, M.; Khalil, M.; Ulmer, H. [Universitaetskinderklinik Heidelberg (Germany). Kardiologie; Krissak, R.; Kauczor, H.U. [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany). Radiologie; Ley, S. [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany). Radiologie; Universitaetsklinik Heidelberg (Germany). Paediatrische Kardiologie; Arnold, R. [Universitaetskinderklinik Heidelberg (Germany). Kardiologie; Universitaetskinderklinik Freiburg (Germany). Paediatrische Kardiologie; Boese, J. [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany). Medizinische Physik in der Radiologie; Siemens AG, Medical Solutions, Forchheim (Germany). Angiography, Fluoroscopic and Radiographic Systems; Krug, R. [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany). Medizinische Physik in der Radiologie; Fink, C. [Medizinische Fakultaet Mannheim der Univ. Heidelberg, Mannheim (Germany). Inst. fuer Klinische Radiologie

    2007-08-15

    Purpose: To compare the aortic compliance of the normal-sized aorta of adolescents with Marfan syndrome and healthy controls using MR measurements of the aortic distensibility and pulse wave velocity. Materials and Methods: Fourteen patients (median age: 15 [9-21] years) and 11 healthy subjects (23 [12-32] years) were examined at 1.5 T. The MR protocol included 2D steady-state free precession (SSFP)-CINE MRI of the aortic distensibility and PC-MRI of the pulse wave velocity. All measurements were positioned perpendicular to the descending aorta at the level of the diaphragm for assessing the changes in the aortic cross-sectional areas and additionally above and below this plane for assessing the pulse wave velocity. In addition contrast-enhanced 3D-MR angiography was performed in adolescents with Marfan syndrome to exclude morphologic changes and to prove normal-sized aorta. Results: Compared with control subjects, adolescents with Marfan syndrome had significantly decreased distensibility and significantly increased pulse wave velocity ({chi}{sup 2}-test, p = 0.0002) using an age-related non-linear regression analysis. The related aortic compliance was significantly decreased ({chi}{sup 2}-test, p = 0.0002). There was a good correlation between the two methods (r = 0.86). A low intraobserver variability was found for both methods ({<=} 2 %). (orig.)

  5. Pulse-shaping mechanism in colliding-pulse mode-locked laser diodes

    DEFF Research Database (Denmark)

    Bischoff, Svend; Sørensen, Mads Peter; Mørk, J.

    1995-01-01

    The large signal dynamics of passively colliding pulse mode-locked laser diodes is studied. We derive a model which explains modelocking via the interplay of gain and loss dynamics; no bandwidth limiting element is necessary for pulse formation. It is found necessary to have both fast and slow...... absorber dynamics to achieve mode-locking. Significant chirp is predicted for pulses emitted from long lasers, in agreement with experiment. The pulse width shows a strong dependence on both cavity and saturable absorber length. (C) 1995 American Institute of Physics....

  6. Attention demanding tasks during treadmill walking reduce step width variability in young adults

    Directory of Open Access Journals (Sweden)

    Troy Karen L

    2005-08-01

    Full Text Available Abstract Background The variability of step time and step width is associated with falls by older adults. Further, step time is significantly influenced when performing attention demanding tasks while walking. Without exception, step time variability has been reported to increase in normal and pathologically aging older adults. Because of the role of step width in managing frontal plane dynamic stability, documenting the influence of attention-demanding tasks on step width variability may provide insight to events that can disturb dynamic stability during locomotion and increase fall risk. Preliminary evidence suggests performance of an attention demanding task significantly decreases step width variability of young adults walking on a treadmill. The purpose of the present study was to confirm or refute this finding by characterizing the extent and direction of the effects of a widely used attention demanding task (Stroop test on the step width variability of young adults walking on a motorized treadmill. Methods Fifteen healthy young adults walked on a motorized treadmill at a self-selected velocity for 10 minutes under two conditions; without performing an attention demanding task and while performing the Stroop test. Step width of continuous and consecutive steps during the collection was derived from the data recorded using a motion capture system. Step width variability was computed as the standard deviation of all recorded steps. Results Step width decreased four percent during performance of the Stroop test but the effect was not significant (p = 0.10. In contrast, the 16 percent decrease in step width variability during the Stroop test condition was significant (p = 0.029. Conclusion The results support those of our previous work in which a different attention demanding task also decreased step width variability of young subjects while walking on a treadmill. The decreased step width variability observed while performing an attention

  7. Clarifying Normalization

    Science.gov (United States)

    Carpenter, Donald A.

    2008-01-01

    Confusion exists among database textbooks as to the goal of normalization as well as to which normal form a designer should aspire. This article discusses such discrepancies with the intention of simplifying normalization for both teacher and student. This author's industry and classroom experiences indicate such simplification yields quicker…

  8. Attentional Focus and Grip Width Influences on Bench Press Resistance Training.

    Science.gov (United States)

    Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, JuanCarlos; Andersen, Lars L

    2018-04-01

    This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG of the filtered signals were normalized to maximum EMG of each muscle. Both grip width and focus influenced the muscle activity level, but there were no significant interactions between these variables. Exploratory analyses suggested that an internal focus may slightly (4%-6%) increase pectoralis major activity at wider grip widths and triceps brachii activity at narrower grip widths, but this should be confirmed or rejected in a study with a larger sample size or through a meta-analysis of research to date.

  9. An Economical Fast Discriminator for Nuclear Pulse Counting

    International Nuclear Information System (INIS)

    Issarachai, Opas; Punnachaiya, Suvit

    2009-07-01

    Full text: This research work was aimed to develop a fast discriminator at low cost but high capability for discrimination a nanosecond nuclear pulse. The fast discriminator can be used in association with fast photon counting system. The designed structure consisted of the ultra-fast voltage comparator using ADCMP601 integrated circuit, the monostable multivibrator with controllable pulse width output by propagation delay of logic gate, and the fast response buffer amplifier. The tested results of pulse height discrimination of 0-5 V nuclear pulse with 20 ns (FWHM) pulse width showed the correlation coefficient (R 2 ) between discrimination level and pulse height was 0.998, while the pulse rate more than 10 MHz could be counted. The 30 ns logic pulse width output revealed high stable and could be smoothly driven to low impedance load at 50 Ω. For pulse signal transmission to the counter, it was also found that the termination of reflected signal must be considered because it may cause pulse counting error

  10. Direct measurement of the W boson width

    Energy Technology Data Exchange (ETDEWEB)

    Abazov, V.M.; /Dubna, JINR; Abbott, B.; /Oklahoma U.; Abolins, M.; /Michigan State U.; Acharya, B.S.; /Tata Inst.; Adams, M.; /Illinois U., Chicago; Adams, T.; /Florida State U.; Aguilo, E.; /Alberta U. /Simon Fraser U. /McGill U.; Ahsan, M.; /Kansas State U.; Alexeev, G.D.; /Dubna, JINR; Alkhazov, G.; /St. Petersburg, INP; Alton, A.; /Michigan U. /Northeastern U.

    2009-09-01

    We present a direct measurement of the width of the W boson using the shape of the transverse mass distribution of W {yields} e{nu} candidates selected in 1 fb{sup -1} of data collected with the D0 detector at the Fermilab Tevatron collider in p{bar p} collisions at {radical}s = 1.96 TeV. We use the same methods and data sample that were used for our recently published W boson mass measurement, except for the modeling of the recoil, which is done with a new method based on a recoil library. Our result, 2.028 {+-} 0.072 GeV, is in agreement with the predictions of the standard model and is the most precise direct measurement result from a single experiment to date.

  11. Width lines of non hydrogenoid ions

    International Nuclear Information System (INIS)

    Bertuccelli, D.; Bertuccelli, G.; Di Rocco, H.O.

    1990-01-01

    An extensive theoretical and experimental work was carried out on the ns-np and np-nd line widths (w) of noble gases after ionization (n=n 0 +1, were n 0 is the principal quantum number of the fundamental configuration). A high current 'pinch' discharge was used as source. Electron density and temperature were estimated to be N e =2.65x10 16 cm -3 and T=1.45x10 4 K respectively. Calculations were based on a semi-empirical approximation and the matrix elements (or transition probabilities) were evaluated in different approximation. Comparing our measurements with those of other authors, a systematic tendency, with a dependence on atomic number Z and ionization energy of the higher level L, was established. Finally, it has been established that for N e >10 17 cm -3 , w ∝ N e γ , where γ=5/6. (Author). 8 refs., 1 fig., 1 tab

  12. Lake Basin Fetch and Maximum Length/Width

    Data.gov (United States)

    Minnesota Department of Natural Resources — Linear features representing the Fetch, Maximum Length and Maximum Width of a lake basin. Fetch, maximum length and average width are calcuated from the lake polygon...

  13. Half-width at half-maximum, full-width at half-maximum analysis

    Indian Academy of Sciences (India)

    addition to the well-defined parameter full-width at half-maximum (FWHM). The distribution of ... optical side-lobes in the diffraction pattern resulting in steep central maxima [6], reduc- tion of effects of ... and broad central peak. The idea of.

  14. Development of picosecond pulsed electron beam monitor

    International Nuclear Information System (INIS)

    Hosono, Y.; Nakazawa, M.; Ueda, T.; Kobayasi, T.; Yosida, Y.; Ohkuma, J.; Okuda, S.; Suemine, S.

    1993-01-01

    For the picosecond pulsed electron beam of a linear accelerator a simple monitor using an electric connector has been developed which is constructed with SMA, BNC, N type electric connector through pipe (inner diameter = 50 mm or 100 mm). Under the measurement conditions of peak current (26A-900A) and narrow pulse width (Pw = 10 ps(FWHM), Pw = 30 ps(FWHM)), the following characteristics of this monitor were obtained, (A) rise time is less than 25 ps (B) the amplitude of the monitor output pulse is proportional directly to the area of cross section of the electrode. (author)

  15. Moderate and high intensity pulsed electric fields

    OpenAIRE

    Timmermans, Rian Adriana Hendrika

    2018-01-01

    Pulsed Electric Field (PEF) processing has gained a lot of interest the last decades as mild processing technology as alternative to thermal pasteurisation, and is suitable for preservation of liquid food products such as fruit juices. PEF conditions typically applied at industrial scale for pasteurisation are high intensity pulsed electric fields aiming for minimal heat load, with an electric field strength (E) in the range of 15 − 20 kV/cm and pulse width (τ) between 2 − 20 μs. Alternativel...

  16. Control of laser pulse waveform in longitudinally excited CO2 laser by adjustment of excitation circuit

    Science.gov (United States)

    Uno, Kazuyuki; Jitsuno, Takahisa

    2018-05-01

    In a longitudinally excited CO2 laser that had a 45 cm-long discharge tube with a 1:1:2 mixture of CO2/N2/He gas at a pressure of 3.0 kPa, we realized the generation of a short laser pulse with a spike pulse width of about 200 ns and a pulse tail length of several tens of microseconds, control of the energy ratio of the spike pulse part to the pulse tail part in the short laser pulse, the generation of a long laser pulse with a pulse width of several tens of microseconds, and control of the pulse width in the long laser pulse, by using four types of excitation circuits in which the capacitance was adjusted. In the short laser pulse, the energy ratio was in the range 1:14-1:112. In the long laser pulse, the pulse width was in the range 25.7-82.7 μs.

  17. PSPICE simulation of bipolar pulse converter based on short-circuited coaxial transmission line

    International Nuclear Information System (INIS)

    Shi Lei; Fan Yajun

    2010-01-01

    The operating principle of the bipolar pulse converter based on short-circuited coaxial transmission line type is given. The output bipolar pulses are simulated by using PSPICE program on condition of different electric length and different impedance of the short-circuited coaxial transmission line. The bipolar pulses are generated by using unipolar pulse with pulse width of 2 ns in experiment, the experimental result fit well with the simulation result. (authors)

  18. Self-compression of femtosecond deep-ultraviolet pulses by filamentation in krypton.

    Science.gov (United States)

    Adachi, Shunsuke; Suzuki, Toshinori

    2017-05-15

    We demonstrate self-compression of deep-ultraviolet (DUV) pulses by filamentation in krypton. In contrast to self-compression in the near-infrared, that in the DUV is associated with a red-shifted sub-pulse appearing in the pulse temporal profile. The achieved pulse width of 15 fs is the shortest among demonstrated sub-mJ deep-ultraviolet pulses.

  19. Dual-Pulse Pulse Position Modulation (DPPM) for Deep-Space Optical Communications: Performance and Practicality Analysis

    Science.gov (United States)

    Li, Jing; Hylton, Alan; Budinger, James; Nappier, Jennifer; Downey, Joseph; Raible, Daniel

    2012-01-01

    Due to its simplicity and robustness against wavefront distortion, pulse position modulation (PPM) with photon counting detector has been seriously considered for long-haul optical wireless systems. This paper evaluates the dual-pulse case and compares it with the conventional single-pulse case. Analytical expressions for symbol error rate and bit error rate are first derived and numerically evaluated, for the strong, negative-exponential turbulent atmosphere; and bandwidth efficiency and throughput are subsequently assessed. It is shown that, under a set of practical constraints including pulse width and pulse repetition frequency (PRF), dual-pulse PPM enables a better channel utilization and hence a higher throughput than it single-pulse counterpart. This result is new and different from the previous idealistic studies that showed multi-pulse PPM provided no essential information-theoretic gains than single-pulse PPM.

  20. Decay-out from low-lying superdeformed bands in Pb isotopes: Tunneling widths in a two-level mixing model

    International Nuclear Information System (INIS)

    Wilson, A.N.; Davidson, P.M.

    2004-01-01

    A recently developed two-level mixing model of superdeformed decay is applied to evaluate the tunneling width between the superdeformed and normally deformed potential wells in 192 Pb and 194 Pb. Estimates are made of level densities and γ decay widths for levels in the normally deformed well, which are required for evaluation of the model. Experimental quasicontinuum results are used to suggest a spin-dependent reduction of the energy gap in the level spectrum, resulting in approximately constant level densities and decay widths in the normal well over the decay-out region for each isotope. However, it transpires that the model's prediction of the tunneling width is nearly independent of the normally deformed state widths for both isotopes. This observation is used to extract potential barrier heights for the two nuclei that depend mainly on experimentally determined values

  1. Characterizing graphs of maximum matching width at most 2

    DEFF Research Database (Denmark)

    Jeong, Jisu; Ok, Seongmin; Suh, Geewon

    2017-01-01

    The maximum matching width is a width-parameter that is de ned on a branch-decomposition over the vertex set of a graph. The size of a maximum matching in the bipartite graph is used as a cut-function. In this paper, we characterize the graphs of maximum matching width at most 2 using the minor o...

  2. Pulse frequency in pulsed brachytherapy based on tissue repair kinetics

    International Nuclear Information System (INIS)

    Sminia, Peter; Schneider, Christoph J.; Koedooder, Kees; Tienhoven, Geertjan van; Blank, Leo E.C.M.; Gonzalez Gonzalez, Dionisio

    1998-01-01

    Purpose: Investigation of normal tissue sparing in pulsed brachytherapy (PB) relative to continuous low-dose rate irradiation (CLDR) by adjusting pulse frequency based on tissue repair characteristics. Method: Using the linear quadratic model, the relative effectiveness (RE) of a 20 Gy boost was calculated for tissue with an α/β ratio ranging from 2 to 10 Gy and a half-time of sublethal damage repair between 0.1 and 3 h. The boost dose was considered to be delivered either in a number of pulses varying from 2 to 25, or continuously at a dose rate of 0.50, 0.80, or 1.20 Gy/h. Results: The RE of 20 Gy was found to be identical for PB in 25 pulses of 0.80 Gy each h and CLDR delivered at 0.80 Gy/h for any α/β value and for a repair half-time > 0.75 h. When normal tissue repair half-times are assumed to be longer than tumor repair half-times, normal tissue sparing can be obtained, within the restriction of a fixed overall treatment time, with higher dose per pulse and longer period time (time elapsed between start of pulse n and start of pulse n + 1). An optimum relative normal tissue sparing larger than 10% was found with 4 pulses of 5 Gy every 8 h. Hence, a therapeutic gain might be obtained when changing from CLDR to PB by adjusting the physical dose in such a way that the biological dose on the tumor is maintained. The normal tissue-sparing phenomenon can be explained by an increase in RE with longer period time for tissue with high α/β ratio and fast or intermediate repair half-time, and the RE for tissue with low α/β ratio and long repair half-time remains almost constant. Conclusion: Within the benchmark of the LQ model, advantage in normal tissue-sparing is expected when matching the pulse frequency to the repair kinetics of the normal tissue exposed. A period time longer than 1 h may lead to a reduction of late normal tissue complications. This theoretical advantage emphasizes the need for better knowledge of human tissue-repair kinetics

  3. Controllable pulse parameter transcranial magnetic stimulator with enhanced circuit topology and pulse shaping

    Science.gov (United States)

    Peterchev, Angel V.; DʼOstilio, Kevin; Rothwell, John C.; Murphy, David L.

    2014-10-01

    Objective. This work aims at flexible and practical pulse parameter control in transcranial magnetic stimulation (TMS), which is currently very limited in commercial devices. Approach. We present a third generation controllable pulse parameter device (cTMS3) that uses a novel circuit topology with two energy-storage capacitors. It incorporates several implementation and functionality advantages over conventional TMS devices and other devices with advanced pulse shape control. cTMS3 generates lower internal voltage differences and is implemented with transistors with a lower voltage rating than prior cTMS devices. Main results. cTMS3 provides more flexible pulse shaping since the circuit topology allows four coil-voltage levels during a pulse, including approximately zero voltage. The near-zero coil voltage enables snubbing of the ringing at the end of the pulse without the need for a separate active snubber circuit. cTMS3 can generate powerful rapid pulse sequences (\\lt 10 ms inter pulse interval) by increasing the width of each subsequent pulse and utilizing the large capacitor energy storage, allowing the implementation of paradigms such as paired-pulse and quadripulse TMS with a single pulse generation circuit. cTMS3 can also generate theta (50 Hz) burst stimulation with predominantly unidirectional electric field pulses. The cTMS3 device functionality and output strength are illustrated with electrical output measurements as well as a study of the effect of pulse width and polarity on the active motor threshold in ten healthy volunteers. Significance. The cTMS3 features could extend the utility of TMS as a research, diagnostic, and therapeutic tool.

  4. Molecular dynamics study of lubricant depletion by pulsed laser heating

    Science.gov (United States)

    Seo, Young Woo; Rosenkranz, Andreas; Talke, Frank E.

    2018-05-01

    In this study, molecular dynamics simulations were performed to numerically investigate the effect of pulsed laser heating on lubricant depletion. The maximum temperature, the lubricant depletion width, the number of evaporated lubricant beads and the number of fragmented lubricant chains were studied as a function of laser peak power, pulse duration and repetition rate. A continuous-wave laser and a square pulse laser were simulated and compared to a Gaussian pulse laser. With increasing repetition rate, pulsed laser heating was found to approach continuous-wave laser heating.

  5. Driver circuit for pulse modulation of a semiconductor laser

    International Nuclear Information System (INIS)

    Ueki, A.

    1975-01-01

    A pulse modulation driver circuit for a semiconductor laser is disclosed which discriminates among input pulse signals composed of binary codes to detect the occurrence of a pulse having a code of ''I'' following a pulse having a code of ''0''. Detection of this pattern is used to control the driver to increase either or both the width or peak value of the pulse having a code of 1. The effect of this is to eliminate a pattern effect in the light emitted by the semiconductor laser caused by an attenuation of the population inversion in the laser. (U.S.)

  6. Effect of idler absorption in pulsed optical parametric oscillators.

    Science.gov (United States)

    Rustad, Gunnar; Arisholm, Gunnar; Farsund, Øystein

    2011-01-31

    Absorption at the idler wavelength in an optical parametric oscillator (OPO) is often considered detrimental. We show through simulations that pulsed OPOs with significant idler absorption can perform better than OPOs with low idler absorption both in terms of conversion efficiency and beam quality. The main reason for this is reduced back conversion. We also show how the beam quality depends on the beam width and pump pulse length, and present scaling relations to use the example simulations for other pulsed nanosecond OPOs.

  7. Beam-width spreading of vortex beams in free space

    Science.gov (United States)

    Wang, Weiwei; Li, Jinhong; Duan, Meiling

    2018-01-01

    Based on the extended Huygens-Fresnel principle and the definition of second-order moments of the Wigner distribution function, the analytical expression for the beam-width spreading of Gaussian Schell-model (GSM) vortex beams in free space are derived, and used to study the influence of beam parameters on the beam-width spreading of GSM vortex beams. With the increment of the propagation distance, the beam-width spreading of GSM vortex beams will increase; the bigger the topological charge, spatial correlation length, wavelength and waist width are, the smaller the beam-width spreading is.

  8. Narrow-width mechanism of a=5 Ξ-state

    International Nuclear Information System (INIS)

    Kumagai-Fuse, I.; Akaishi, Y.

    1995-04-01

    Narrow-width mechanism of ≡ 5 H is discussed by calculating conversion widths to all its possible decay channels. Since the conversion processes have small reaction Q values, the three- and four- body decays are strongly suppressed owing to small phase volumes available. Decay widths to the two-body channels are significantly reduced by the distortion of emitted-particle waves. This mechanism brings about a narrow width of ≡ 5 H. The total width is estimated to be 0.87 MeV, in which the largest contribution comes from the decay into the Λ 4 H * +Λ channel. (author)

  9. Propagation of optical pulses in a resonantly absorbing medium: Observation of negative velocity in Rb vapor

    International Nuclear Information System (INIS)

    Tanaka, H.; Hayami, K.; Furue, S.; Nakayama, K.; Niwa, H.; Kohmoto, T.; Kunitomo, M.; Fukuda, Y.

    2003-01-01

    Propagation of optical pulses in a resonantly absorbing medium is studied. Propagation time of nanosecond pulses was measured for the Rb D 1 transition. At the center of two absorption lines, delay of the pulse peak which is about ten times as large as the pulse width was observed, where zero delay is defined for the propagation with the light velocity in vacuum. On the other hand, at the peak of an absorption line, negative delay was observed for large absorption, where the advance time is as large as 25% of the pulse width. Simulation including the effect of absorption and phase shift reproduced well the experimental results

  10. Pulse plating

    CERN Document Server

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  11. GAP WIDTH STUDY IN LASER BUTT-WELDING

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    power : 2 and 2.6 kW and the focal point position : 0 and -1.2 mm. Quality of all the butt welds are destructively tested according to ISO 13919-1.Influences of the variable process parameters to the maximum allowable gap width are observed as (1) the maximum gap width is inversely related......In this paper the maximum allowable gap width in laser butt-welding is intensively studied. The gap width study (GWS) is performed on the material of SST of W1.4401 (AISI 316) under various welding conditions, which are the gap width : 0.00-0.50 mm, the welding speed : 0.5-2.0 m/min, the laser...... to the welding speed, (2) the larger laser power leads to the bigger maximum allowable gap width and (3) the focal point position has very little influence on the maximum gap width....

  12. Birkhoff normalization

    NARCIS (Netherlands)

    Broer, H.; Hoveijn, I.; Lunter, G.; Vegter, G.

    2003-01-01

    The Birkhoff normal form procedure is a widely used tool for approximating a Hamiltonian systems by a simpler one. This chapter starts out with an introduction to Hamiltonian mechanics, followed by an explanation of the Birkhoff normal form procedure. Finally we discuss several algorithms for

  13. Effects of excitation spectral width on decay profile of weakly confined excitons

    International Nuclear Information System (INIS)

    Kojima, O.; Isu, T.; Ishi-Hayase, J.; Kanno, A.; Katouf, R.; Sasaki, M.; Tsuchiya, M.

    2008-01-01

    We report the effect due to a simultaneous excitation of several exciton states on the radiative decay profiles on the basis of the nonlocal response of weakly confined excitons in GaAs thin films. In the case of excitation of single exciton state, the transient grating signal has two decay components. The fast decay component comes from nonlocal response, and the long-lived component is attributed to free exciton decay. With an increase of excitation spectral width, the nonlocal component becomes small in comparison with the long-lived component, and disappears under irradiation of a femtosecond-pulse laser with broader spectral width. The transient grating spectra clearly indicates the contribution of the weakly confined excitons to the signal, and the exciton line width hardly changes by excitation spectral width. From these results, we concluded that the change of decay profile is attributed not to the many-body effect but to the effect of simultaneous excitation of several exciton states

  14. Transient current changes induced in pin-diodes by nanosecond electron pulses

    International Nuclear Information System (INIS)

    Leonhardt, J.W.; Goldner, R.; Bos, J.; Mehnert, R.

    1984-01-01

    The electron pulse technique can be applied as a diagnostic method to measure charge carrier lifetimes, diffusion length or junction width in semiconductor p + -i-n + diodes. The described effect of the pulse length dependence on the electron energy might be of importance as an energy monitor for pulsed electron accelerators. (author)

  15. Electrical and optical analysis of fast transient discharges in a pulsed corona pilot unit

    NARCIS (Netherlands)

    Blom, P.P.M.; Smulders, H.W.M.; Heesch, van E.J.M.; Laan, van der P.C.T.

    1997-01-01

    We give a detailed analysis of intense pulsed corona dis charges. CCD movies and current, voltage and energy in put measurements are the basis of the description. The discharges are generated in a 1.5 kW pilot unit, which cre ates pulsed corona discharges energized by 100 kV pulses of 200 us width,

  16. A Comparison of Arch Width with Angle Classification and Wits Appraisal in Class 2 Division 1 and Class 1 Individuals.

    Science.gov (United States)

    1983-05-01

    longitudinal changes in arch width between lateral incisors, canines and second premolars or deciduous second molars at four stages of dental eruption in 22 male... dental arch or skeletal widths. Also, he made no attempt to divide his sample into normal and malocclusion groups. -J 7 Warren (1959) studying twenty...buccal crossbite of the posterior teeth Many clinicians believe that this problem is highly correlated with tfte type or classification of malocclusion

  17. Effects of pulse-to-pulse residual species on discharges in repetitively pulsed discharges through packed bed reactors

    Science.gov (United States)

    Kruszelnicki, Juliusz; Engeling, Kenneth W.; Foster, John E.; Kushner, Mark J.

    2016-09-01

    Atmospheric pressure dielectric barrier discharges (DBDs) sustained in packed bed reactors (PBRs) are being investigated for conversion of toxic and waste gases, and CO2 removal. These discharges are repetitively pulsed having varying flow rates and internal geometries, which results in species from the prior pulse still being in the discharge zone at the time the following discharge pulse occurs. A non-negligible residual plasma density remains, which effectively acts as preionization. This residual charge changes the discharge properties of subsequent pulses, and may impact important PBR properties such as chemical selectivity. Similarly, the residual neutral reactive species produced during earlier pulses will impact the reaction rates on subsequent pulses. We report on results of a computational investigation of a 2D PBR using the plasma hydrodynamics simulator nonPDPSIM. Results will be discussed for air flowing though an array of dielectric rods at atmospheric pressure. The effects of inter-pulse residual species on PBR discharges will be quantified. Means of controlling the presence of residual species in the reactor through gas flow rate, pulse repetition, pulse width and geometry will be described. Comparisons will be made to experiments. Work supported by US DOE Office of Fusion Energy Science and the National Science Foundation.

  18. Electrical pulse burnout testing of light-emitting diodes

    International Nuclear Information System (INIS)

    Kalma, A.H.; Fischer, C.J.

    1975-01-01

    Electrical pulse burnout thresholds were measured in GaAs, GaAsP, and GaP light-emitting diodes (LEDs) by studying the degradation in light output and the change in I-V characteristics both during the pulse and in the steady state. Pulse widths ranging from a few hundred nsec to 100 μsec were used. Light output degradation was the most sensitive parameter and was used to determine the thresholds. Just above threshold, damage is caused by an increase in generation-recombination current in the space-charge retion. This current is non-radiative and the light output drops, but the damage is not catastrophic. At higher power, the junction burns through and shunt resistance paths are formed which more drastically degrade the light output. The experimental data match reasonably with the theoretical Wunsch--Bell/Tasca model if a burnout area of 1 / 10 the junction area is assumed. Both the adiabatic term (At -1 ) and the heat flow term (Bt - /sup 1 / 2 /) contribute in all devices, and the equilibrium term (C) contributes in some GaAsP devices. The scatter in the data for GaAs devices is greater than that for GaAsP devices, apparently because the former types have a significant fraction of mavericks with lower-than-normal thresholds. The use of LEDs to examine electrical pulse burnout is advantageous because the light output is quite sensitive to damage and the combined measurement of optical and electrical properties provides additional information about the mechanisms involved

  19. Pulsed TRIGA reactor as substitute for long pulse spallation neutron source

    International Nuclear Information System (INIS)

    Whittemore, W.L.

    1999-01-01

    TRIGA reactor cores have been used to demonstrate various pulsing applications. The TRIGA reactor fuel (U-ZrH x ) is very robust especially in pulsing applications. The features required to produce 50 pulses per second have been successfully demonstrated individually, including pulse tests with small diameter fuel rods. A partially optimized core has been evaluated for pulses at 50 Hz with peak pulsed power up to 100 MW and an average power up to 10 MW. Depending on the design, the full width at half power of the individual pulses can range between 2000 μsec to 3000 μsec. Until recently, the relatively long pulses (2000 μsec to 3000 μsec) from a pulsed thermal reactor or a long pulse spallation source (LPSS) have been considered unsuitable for time-of-flight measurements of neutron scattering. More recently considerable attention has been devoted to evaluating the performance of long pulse (1000 to 4000 μs) spallation sources for the same type of neutron measurements originally performed only with short pulses from spallation sources (SPSS). Adequate information is available to permit meaningful comparisons between CW, SPSS, and LPSS neutron sources. Except where extremely high resolution is required (fraction of a percent), which does require short pulses, it is demonstrated that the LPSS source with a 1000 msec or longer pulse length and a repetition rate of 50 to 60 Hz gives results comparable to those from the 60 MW ILL (CW) source. For many of these applications the shorter pulse is not necessarily a disadvantage, but it is not an advantage over the long pulse system. In one study, the conclusion is that a 5 MW 2000 μsec LPSS source improves the capability for structural biology studies of macromolecules by at least a factor of 5 over that achievable with a high flux reactor. Recent studies have identified the advantages and usefulness of long pulse neutron sources. It is evident that the multiple pulse TRIGA reactor can produce pulses comparable to

  20. Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter

    CERN Document Server

    Aderholz, M; Matthewson, R; Lehraus, I no 1; Matthewson, R no 1; Aderholz, M no 1

    1975-01-01

    A Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A group of four identical scintillation counters was constructed and the smallest of the four output pulses was used for selective triggering of the bubble chamber flash with the greater precision engendered by the considerably reduced distribution width. (22 refs).

  1. High-throughput gated photon counter with two detection windows programmable down to 70 ps width

    Energy Technology Data Exchange (ETDEWEB)

    Boso, Gianluca; Tosi, Alberto, E-mail: alberto.tosi@polimi.it; Zappa, Franco [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Mora, Alberto Dalla [Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy)

    2014-01-15

    We present the design and characterization of a high-throughput gated photon counter able to count electrical pulses occurring within two well-defined and programmable detection windows. We extensively characterized and validated this instrument up to 100 Mcounts/s and with detection window width down to 70 ps. This instrument is suitable for many applications and proves to be a cost-effective and compact alternative to time-correlated single-photon counting equipment, thanks to its easy configurability, user-friendly interface, and fully adjustable settings via a Universal Serial Bus (USB) link to a remote computer.

  2. High-throughput gated photon counter with two detection windows programmable down to 70 ps width

    International Nuclear Information System (INIS)

    Boso, Gianluca; Tosi, Alberto; Zappa, Franco; Mora, Alberto Dalla

    2014-01-01

    We present the design and characterization of a high-throughput gated photon counter able to count electrical pulses occurring within two well-defined and programmable detection windows. We extensively characterized and validated this instrument up to 100 Mcounts/s and with detection window width down to 70 ps. This instrument is suitable for many applications and proves to be a cost-effective and compact alternative to time-correlated single-photon counting equipment, thanks to its easy configurability, user-friendly interface, and fully adjustable settings via a Universal Serial Bus (USB) link to a remote computer

  3. Normal dispersion femtosecond fiber optical parametric oscillator.

    Science.gov (United States)

    Nguyen, T N; Kieu, K; Maslov, A V; Miyawaki, M; Peyghambarian, N

    2013-09-15

    We propose and demonstrate a synchronously pumped fiber optical parametric oscillator (FOPO) operating in the normal dispersion regime. The FOPO generates chirped pulses at the output, allowing significant pulse energy scaling potential without pulse breaking. The output average power of the FOPO at 1600 nm was ∼60  mW (corresponding to 1.45 nJ pulse energy and ∼55% slope power conversion efficiency). The output pulses directly from the FOPO were highly chirped (∼3  ps duration), and they could be compressed outside of the cavity to 180 fs by using a standard optical fiber compressor. Detailed numerical simulation was also performed to understand the pulse evolution dynamics around the laser cavity. We believe that the proposed design concept is useful for scaling up the pulse energy in the FOPO using different pumping wavelengths.

  4. The significance of biometric parameters in determining anterior teeth width

    Directory of Open Access Journals (Sweden)

    Strajnić Ljiljana

    2013-01-01

    Full Text Available Background/Aim. An important element of prosthetic treatment of edentulous patients is selecting the size of anterior artificial teeth that will restore the natural harmony of one’s dentolabial structure as well as the whole face. The main objective of this study was to determine the correlation between the inner canthal distance (ICD and interalar width (IAW on one side and the width of both central incisors (CIW, the width of central and lateral incisors (CLIW, the width of anterior teeth (ATW, the width between the canine cusps (CCW, which may be useful in clinical practice. Methods. A total of 89 subjects comprising 23 male and 66 female were studied. Their age ranged from 19 to 34 years with the mean of 25 years. Only the subjects with the preserved natural dentition were included in the sample. All facial and intraoral tooth measurements were made with a Boley Gauge (Buffalo Dental Manufacturing Co., Brooklyn NY, USA having a resolution of 0.1mm. Results. A moderate correlation was established between the interalar width and combined width of anterior teeth and canine cusp width (r = 0.439, r = 0.374. A low correlation was established between the inner canthal distance and the width of anterior teeth and canine cusp width (r = 0.335, r = 0.303. The differences between the two genders were highly significant for all the parameters (p < 0.01. The measured facial distances and width of anterior teeth were higher in men than in women. Conclusion. The results of this study suggest that the examined interalar width and inner canthal distance cannot be considered reliable guidelines in the selection of artificial upper anterior teeth. However, they may be used as a useful additional factor combined with other methods for objective tooth selection. The final decision should be made while working on dentures fitting models with the patient’s consent.

  5. Isolated PWM DC-AC SICAM with an active capacitive voltage clamp[Pulse Density Modulated; Pulse Width Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, i.e. a true bidirectional bridge, which operation is aimed towards amplification of the audio signal. In order to solve the problem with the commutation of the load current, a dead time between the incoming and outgoing bidirectional switch is implemented, while a capacitive voltage clamp is used to keep the induced overvoltage to reasonable levels. The energy stored in the clamping capacitor is not wasted as in the dissipative clamps, but is rather transferred back to the primary side for further processing using an auxiliary isolated single-switch converter, i.e. an active clamping technique is used. (au)

  6. Step width alters iliotibial band strain during running.

    Science.gov (United States)

    Meardon, Stacey A; Campbell, Samuel; Derrick, Timothy R

    2012-11-01

    This study assessed the effect of step width during running on factors related to iliotibial band (ITB) syndrome. Three-dimensional (3D) kinematics and kinetics were recorded from 15 healthy recreational runners during overground running under various step width conditions (preferred and at least +/- 5% of their leg length). Strain and strain rate were estimated from a musculoskeletal model of the lower extremity. Greater ITB strain and strain rate were found in the narrower step width condition (p running, especially in persons whose running style is characterized by a narrow step width, may be beneficial in the treatment and prevention of running-related ITB syndrome.

  7. Pulsed power

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The key element of our pulsed power program is concentration of power in time and space by suppression of breakdown in dielectrics and in vacuum. Magnetically insulated vacuum transmission lines and magnetic suppression of insulator flashover have continued as the main reserch directions. Vacuum insulated line studies at Physics International have been expanded and a test bed at Sandia, called MITE (Magnetically Insulated Transmission Experiment), is under development. The choice for the baseline EBFA design will depend on the outcome of these studies and should be made in July 1977. The slow and intermediate speed pulsed power approaches to EBFA will be based on Proto I and Proto II results and several of the projected EBFA subsystems are presently being tested in Proto II. A further stage of power concentration, within the vacuum diode itself, would considerably ease the burden on dielectrics; methods of power multiplication involving magnetically imploded plasmas are being considered and tests have begun using the Ripple III apparatus

  8. High-intensity pulsed electric field variables affecting Staphylococcus aureus inoculated in milk.

    Science.gov (United States)

    Sobrino-López, A; Raybaudi-Massilia, R; Martín-Belloso, O

    2006-10-01

    Staphylococcus aureus is an important milk-related pathogen that is inactivated by high-intensity pulsed electric fields (HIPEF). In this study, inactivation of Staph. aureus suspended in milk by HIPEF was studied using a response surface methodology, in which electric field intensity, pulse number, pulse width, pulse polarity, and the fat content of milk were the controlled variables. It was found that the fat content of milk did not significantly affect the microbial inactivation of Staph. aureus. A maximum value of 4.5 log reductions was obtained by applying 150 bipolar pulses of 8 mus each at 35 kV/cm. Bipolar pulses were more effective than those applied in the monopolar mode. An increase in electric field intensity, pulse number, or pulse width resulted in a drop in the survival fraction of Staph. aureus. Pulse widths close to 6.7 micros lead to greater microbial death with a minimum number of applied pulses. At a constant treatment time, a greater number of shorter pulses achieved better inactivation than those treatments performed at a lower number of longer pulses. The combined action of pulse number and electric field intensity followed a similar pattern, indicating that the same fraction of microbial death can be reached with different combinations of the variables. The behavior and relationship among the electrical variables suggest that the energy input of HIPEF processing might be optimized without decreasing the microbial death.

  9. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network.

    Science.gov (United States)

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang; Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin

    2014-06-01

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  10. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network

    Energy Technology Data Exchange (ETDEWEB)

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang, E-mail: zhaoliang0526@163.com; Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin [Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi' an, Shaanxi 710024 (China)

    2014-06-15

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  11. Safe Operation and Alignment of the Variable Pulse Width Laser at the US Army Research Laboratory

    Science.gov (United States)

    2016-02-01

    that the stored lamp parameters match the desired flashlamp operating parameters. Then go back to the main menu and press “B” to select the desired...operating the laser at a high voltage, either press “STOP” on the flashlamp controller to discharge the capacitors or fire the laser a few times at

  12. On the Myth of Pulse Width Modulated Spectrum in Theory and Practice

    DEFF Research Database (Denmark)

    Knott, Arnold; Pfaffinger, Gerhard; Andersen, Michael Andreas E.

    2009-01-01

    Switch-mode audio power amplifiers are commonly used in sound reproduction. Their well known drawback is the radiation of high frequent energy, which can disturb radio and TV receivers. The designer of switch-mode audio equipment therefore needs to make arrangements to prevent this coupling which...

  13. Femtosecond pulse-width dependent trapping and directional ejection dynamics of dielectric nanoparticles

    KAUST Repository

    Chiang, Weiyi; Usman, Anwar; Masuhara, Hiroshi

    2013-01-01

    the repulsive and attractive forces. We also show that the directional ejections occur only when the number of nanoparticles confined in the trapping site exceeds a definite threshold. We interpret our data by considering the formation of transient assembly

  14. A pulse-width modulated, high reliability charge controller for small photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    Gerken, K. [Morningstar Corp., Olney, MD (United States); Welsh, D. [Morningstar Corp., Encinitas, CA (United States)

    1997-02-01

    This report presents the results of a development effort to design, test and begin production of a new class of small photovoltaic (PV) charge controllers. Sandia National Laboratories provided technical support, test data and financial support through a Balance-of-System Development contract. One of the objectives of the development was to increase user confidence in small PV systems by improving the reliability and operating life of the system controllers. Another equally important objective was to improve the economics of small PV systems by extending the battery lifetimes. Using new technology and advanced manufacturing techniques, these objectives were accomplished. Because small stand-alone PV systems account for over one third of all PV modules shipped, the positive impact of improving the reliability and economics of PV systems in this market segment will be felt throughout the industry. The results of verification testing of the new product are also included in this report. The initial design goals and specifications were very aggressive, but the extensive testing demonstrates that all the goals were achieved. Production of the product started in May at a rate of 2,000 units per month. Over 40 Morningstar distributors (5 US and 35 overseas) have taken delivery in the first 2 months of shipments. Initial customer reactions to the new controller have been very favorable.

  15. Modular space-vector pulse-width modulation for nine-switch converters

    DEFF Research Database (Denmark)

    Dehghan, Seyed Mohammad; Amiri, Arash; Mohamadian, Mustafa

    2013-01-01

    Recently, nine-switch inverter (NSI) has been presented as a dual-output inverter with constant frequency (CF) or different frequency (DF) operation modes. However, the CF mode is more interesting because of its lower switching device rating. This study proposes a new space-vector modulation (SVM......) method for the NSI that supports both the CF and DF modes, whereas conventional SVM of NSI can be used only in the DF mode. The proposed SVM can be easily implemented based on the conventional six-switch inverter SVM modules. The performance of the proposed SVM is verified by the simulation...

  16. Carrier-based pulse width modulation technique for a three-to-five ...

    African Journals Online (AJOL)

    Multi-phase (more than three-phase) converters are required mainly for feeding variable speed multi-phase drive systems. This paper discusses one such solution by using direct ac-ac converter that can be used to supply a five-phase two-motor drive system. Matrix converter based two-motor drive system is presented for ...

  17. Microscopic 3D measurement of dynamic scene using optimized pulse-width-modulation binary fringe

    Science.gov (United States)

    Hu, Yan; Chen, Qian; Feng, Shijie; Tao, Tianyang; Li, Hui; Zuo, Chao

    2017-10-01

    Microscopic 3-D shape measurement can supply accurate metrology of the delicacy and complexity of MEMS components of the final devices to ensure their proper performance. Fringe projection profilometry (FPP) has the advantages of noncontactness and high accuracy, making it widely used in 3-D measurement. Recently, tremendous advance of electronics development promotes 3-D measurements to be more accurate and faster. However, research about real-time microscopic 3-D measurement is still rarely reported. In this work, we effectively combine optimized binary structured pattern with number-theoretical phase unwrapping algorithm to realize real-time 3-D shape measurement. A slight defocusing of our proposed binary patterns can considerably alleviate the measurement error based on phase-shifting FPP, making the binary patterns have the comparable performance with ideal sinusoidal patterns. Real-time 3-D measurement about 120 frames per second (FPS) is achieved, and experimental result of a vibrating earphone is presented.

  18. Pulse-Width-Modulation of Neutral-Point-Clamped Sparse Matrix Converter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Gao, F.

    2007-01-01

    input current and output voltage can be achieved with minimized rectification switching loss, rendering the sparse matrix converter as a competitive choice for interfacing the utility grid to (e.g.) defense facilities that require a different frequency supply. As an improvement, sparse matrix converter...... with improved waveform quality. Performances and practicalities of the designed schemes are verified in simulation and experimentally using an implemented laboratory prototype with some representative results captured and presented in the paper....

  19. Bifurcation and Chaos in a Pulse Width modulation controlled Buck Converter

    DEFF Research Database (Denmark)

    Kocewiak, Lukasz; Bak, Claus Leth; Munk-Nielsen, Stig

    2007-01-01

    by a system of piecewise-smooth nonautonomous differential equations. The research are focused on chaotic oscillations analysis and analytical search for bifurcations dependent on parameter. The most frequent route to chaos by the period doubling is observed in the second order DC-DC buck converter. Other...... bifurcations as a complex behaviour in power electronic system evidence are also described. In order to verify theoretical study the experimental DC-DC buck converter was build. The results obtained from three sources were presented and compared. A very good agreement between theory and experiment was observed....

  20. Pengaruh Penambahan PWM (Pulse Width Modulation Pada Generator HHO Tipe Dry Cell

    Directory of Open Access Journals (Sweden)

    Fungky Dyan Pertiwi

    2013-09-01

    Full Text Available Generator HHO memanfaatkan proses elektrolisis air agar mendapatkan gas H2. Namun, pada praktiknya pemakaian arus dari aki yang besar dan temperatur tinggi membuat bejana generator menjadi cepat rusak, sehingga dibutuhkan tambahan rangkaian elektronika PWM pada pengujian generator HHO guna mengatasi permasalahan tersebut. Penelitian menggunakan elektroda plat berjumlah 9 berdimensi 120mm 120mm, tebal 1mm dan dibatasi oleh o-ring dengan diameter 126mm, tebal 3mm. Pengujian dilakukan secara eksperimen dengan 2 kelompok yaitu kelompok control yang mana pengujian tanpa menggunakan PWM serta kelompok uji dimana pengujian menggunakan PWM dengan variasi duty cycle 30%, 50% dan 70%. Pengujian dilakukan hingga temperatur elektrolit 93oC. Hasil uji didapatkan bahwa arus, laju produksi dan efisiensi terbesar didapatkan pada pengujian tanpa PWM yang mencapai 60,6A, 6,033 10-6kg/s dan 25,69%. Namun, pada pengambilan data kedua efisiensi turun menjadi 19,74%. Penambahan PWM pada pengujian berpengaruh pada arus dan temperatur yang stabil meskipun laju produksi dan efisiensi lebih kecil daripada pengujian tanpa PWM. Pengujian dengan PWM pada duty cycle 70% menghasilkan laju produksi dan efisiensi terbesar yang mencapai 1,843 10-6 kg/s dan 15,19%.

  1. The effect of pulse width and contact configuration on paresthesia coverage in spinal cord stimulation

    NARCIS (Netherlands)

    Holsheimer, J.; Buitenweg, Jan R.; Das, John; de Sutter, Paul; Manola, L.; Nuttin, Bart

    Objective. To investigate the effect of stimulus pulsewidth (PW) and contact configuration (CC) on the area of paresthesia (PA), perception threshold (VPT), discomfort threshold (VDT) and usage range (UR) in spinal cord stimulation (SCS). Methods. Chronic pain patients were tested during a follow-up

  2. Pulse Width Modulator Controller Design for a Brushless DC Motor Position Servo.

    Science.gov (United States)

    1987-06-01

    REQC1,REQC2, lAB, ZEC , ICA, 4. + PVAO, Fy5, PVCO,NODE,TRIG1,TRIG2,TRIG3 ,TRIG4, + TRIG5,TRIGS,RA,PLUGVAIMD,VBIND,VCIND) c call TCONST(ICQl, .75-SWl...DC Motors, Master’s Thesis, Naval Postgraduate School, Monterey, Ca., September 1984. 2. MacMillan, Peter N., A CSMP Commutation Model for .’. Design

  3. Pedestal width and ELM size identity studies in JET and DIII-D; implications for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Beurskens, M N A; Lomas, P; Saarelma, S; Balboa, I; Flanagan, J; Giroud, C; Kempenaars, M [EURATOM/UKAEA Fusion Association, Culham Sc. Centre, Abingdon, OX14 3DB (United Kingdom); Osborne, T H; Groebner, R; Leonard, A; Snyder, P B; Bray, B [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Horton, L D [JET-EFDA, Culham Science Centre, OX14 3DB, Abingdon (United Kingdom); Frassinetti, L [Association EURATOM-VR, Alfven Laboratory, School of Electrical Engineering, KTH, Stockholm (Sweden); Nunes, I [Centro de Fusao Nuclear, Associacao EURATOM-IST, Lisboa (Portugal); Crombe, K [Department of Applied Physics, Ghent University, Rozier 44, 9000 Gent (Belgium); Giovannozzi, E [Associazione EURATOM-ENEA Sulla Fusione, Consorzio RFX Padova (Italy); Kohen, N [Association EURATOM-CEA, CEA/DSM/DRFC-Cadarache 13108, St Paul Durance (France); Loarte, A [ITER Organization, CS 90 046, F-13067 Saint Paul lez Durance Cedex (France); Loennroth, J, E-mail: Marc.Beurskens@jet.u [Association EURATOM-Tekes, Helsinki University of Technology (Finland)

    2009-12-15

    The dependence of the H-mode edge transport barrier width on normalized ion gyroradius (rho* = rho/a) in discharges with type I ELMs was examined in experiments combining data for the JET and DIII-D tokamaks. The plasma configuration as well as the local normalized pressure (beta), collisionality (nu*), Mach number and the ratio of ion and electron temperature at the pedestal top were kept constant, while rho* was varied by a factor of four. The width of the steep gradient region of the electron temperature (T{sub e}) and density (n{sub e}) pedestals normalized to machine size showed no or only a weak trend with rho*. A rho{sup 1/2} or rho{sup 1} dependence of the pedestal width, given by some theoretical predictions, is not supported by the current experiments. This is encouraging for the pedestal scaling towards ITER as it operates at lower rho* than existing devices. Some differences in pedestal structure and ELM behaviour were, however, found between the devices; in the DIII-D discharges, the n{sub e} and T{sub e} pedestal were aligned at high rho* but the n{sub e} pedestal shifted outwards in radius relative to T{sub e} as rho* decreases, while on JET the profiles remained aligned while rho* was scanned by a factor of two. The energy loss at an ELM normalized to the pedestal energy increased from 10% to 40% as rho* increased by a factor of two in the DIII-D discharges but no such variation was observed in the case of JET. The measured pedestal pressures and widths were found to be consistent with the predictions from modelling based on peeling-ballooning stability theory, and are used to make projections towards ITER

  4. Low power arcjet thruster pulse ignition

    Science.gov (United States)

    Sarmiento, Charles J.; Gruber, Robert P.

    1987-01-01

    An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

  5. Review of pulsed rf power generation

    International Nuclear Information System (INIS)

    Lavine, T.L.

    1992-04-01

    I am going to talk about pulsed high-power rf generation for normal-conducting electron and positron linacs suitable for applications to high-energy physics in the Next Linear Collider, or NLC. The talk will cover some basic rf system design issues, klystrons and other microwave power sources, rf pulse-compression devices, and test facilities for system-integration studies

  6. Propagating Characteristics of Pulsed Laser in Rain

    Directory of Open Access Journals (Sweden)

    Jing Guo

    2015-01-01

    Full Text Available To understand the performance of laser ranging system under the rain weather condition, we need to know the propagating characteristics of laser pulse in rain. In this paper, the absorption and attenuation coefficients were calculated based on the scattering theories in discrete stochastic media, and the propagating characteristics of laser pulse in rain were simulated and analyzed using Monte-Carlo method. Some simulation results were verified by experiments, and the simulation results are well matched with the experimental data, with the maximal deviation not less than 7.5%. The results indicated that the propagating laser beam would be attenuated and distorted due to the scattering and absorption of raindrops, and the energy attenuation and pulse shape distortion strongly depended on the laser pulse widths.

  7. Hong's grading for evaluating anterior chamber angle width.

    Science.gov (United States)

    Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul

    2012-11-01

    To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

  8. Constant Width Planar Computation Characterizes ACC0

    DEFF Research Database (Denmark)

    Hansen, K.A.

    2004-01-01

    We obtain a characterization of ACC 0 in terms of a natural class of constant width circuits, namely in terms of constant width polynomial size planar circuits. This is shown via a characterization of the class of acyclic digraphs which can be embedded on a cylinder surface in such a way that all...

  9. Stream water responses to timber harvest: Riparian buffer width effectiveness

    Science.gov (United States)

    Barton D. Clinton

    2011-01-01

    Vegetated riparian buffers are critical for protecting aquatic and terrestrial processes and habitats in southern Appalachian ecosystems. In this case study, we examined the effect of riparian buffer width on stream water quality following upland forest management activities in four headwater catchments. Three riparian buffer widths were delineated prior to cutting; 0m...

  10. A five-picosecond electron pulse from ANL (Argonne National Laboratory) L-Band Linac

    International Nuclear Information System (INIS)

    Cox, G.L.; Jonah, C.D.; Ficht, D.T.; Mavrogenes, G.S.; Sauer, M.C. Jr.

    1989-01-01

    The pulse-compression system of the Argonne National Laboratory Chemistry Division L-Band Linac, presented at the 1986 Linear Accelerator Conference at Stanford, California, has been completed. A five-picosecond-wide electron pulse containing 6 x 10 -9 coulomb charge has been achieved. Acceleration parameters and the pulse-width measurement technique are discussed, and future plans for the utilization of this pulse in radiation chemistry studies are presented. 5 refs., 4 figs

  11. Nanosecond time-resolved EPR in pulse radiolysis via the spin echo method

    International Nuclear Information System (INIS)

    Trifunac, A.D.; Norris, J.R.; Lawler, R.G.

    1979-01-01

    The design and operation of a time-resolved electron spin echo spectrometer suitable for detecting transient radicals produced by 3 MeV electron radiolysis is described. Two modes of operation are available: Field swept mode which generates a normal EPR spectrum and kinetic mode in which the time dependence of a single EPR line is monitored. Techniques which may be used to minimize the effects of nonideal microwave pulses and overlapping sample tube signals are described. The principal advantages of the spin echo method over other time-resolved EPR methods are: (1) Improved time resolution (presently approx.30--50 nsec) allows monitoring of fast changes in EPR signals of transient radicals, (2) Lower susceptibility to interference between the EPR signal and the electron beam pulse at short times, and (3) Lack of dependence of transient signals on microwave field amplitude or static field inhomogeneity at short times. The performance of the instrument is illustrated using CIDEP from acetate radical formed in pulsed radiolysis of aqueous solutions of potassium acetate. The relaxation time and CIDEP enhancement factor obtained for this radical using the spin echo method compare favorably with previous determinations using direct detection EPR. Radical decay rates yield estimates of initial radical concentrations of 10 -4 10 -3 M per electron pulse. The Bloch equations are solved to give an expression for the echo signal for samples exhibiting CIDEP using arbitrary microwave pulse widths and distributions of Larmor frequencies. Conditions are discussed under which the time-dependent signal would be distorted by deviations from an ideal nonselective 90 0 --tau--180 0 pulse sequence

  12. Intraflow width variations in Martian and terrestrial lava flows

    Science.gov (United States)

    Peitersen, Matthew N.; Crown, David A.

    1997-03-01

    Flow morphology is used to interpret emplacement processes for lava flows on Earth and Mars. Accurate measurements of flow geometry are essential, particularly for planetary flows where neither compositional sampling nor direct observations of active flows may be possible. Width behavior may indicate a flow's response to topography, its emplacement regime, and its physical properties. Variations in width with downflow distance from the vent may therefore provide critical clues to flow emplacement processes. Flow width is also one of the few characteristics that can be readily measured from planetary mission data with accuracy. Recent analyses of individual flows at two terrestrial and four Martian sites show that widths within an individual flow vary by up to an order of magnitude. Width is generally thought to be correlated to topography; however, recent studies show that this relationship is neither straightforward nor easily quantifiable.

  13. Crack widths in concrete with fibers and main reinforcement

    DEFF Research Database (Denmark)

    Christensen, Frede; Ulfkjær, Jens Peder; Brincker, Rune

    2015-01-01

    The main object of the research work presented in this paper is to establish design tools for concrete structures where main reinforcement is combined with addition of short discrete steel fibers. The work is concerned with calculating and measuring crack widths in structural elements subjected...... to bending load. Thus, the aim of the work is to enable engineers to calculate crack widths for flexural concrete members and analyze how different combinations of amounts of fibers and amounts of main reinforcement can meet a given maximum crack width requirement. A mathematical model including...... the ductility of the fiber reinforced concrete (FRC) is set up and experimental work is conducted in order to verify the crack width model. The ductility of the FRC is taken into account by using the stress crack width relation. The constitutive model for the FRC is based on the idea that the initial part...

  14. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  15. Pulse radiolysis

    International Nuclear Information System (INIS)

    Greenshields, H.; Seddon, W.A.

    1982-03-01

    This supplement to two bibliographies published in 1970 and 1972 lists 734 references to the literature of pulse radiolysis, arranged under eight broad subject headings. The references were compiled by searching Biological Abstracts, Chemical Abstracts, Nuclear Science Abstracts and the Weekly List of Papers in Radiation Chemistry issued by the Radiation Chemistry Data Center of Notre Dame University. Full bibliographic data is given for papers published in the period 1971 to 1974. A personal author index listing more than 600 authors and a similar number of co-authors is included

  16. Malware Normalization

    OpenAIRE

    Christodorescu, Mihai; Kinder, Johannes; Jha, Somesh; Katzenbeisser, Stefan; Veith, Helmut

    2005-01-01

    Malware is code designed for a malicious purpose, such as obtaining root privilege on a host. A malware detector identifies malware and thus prevents it from adversely affecting a host. In order to evade detection by malware detectors, malware writers use various obfuscation techniques to transform their malware. There is strong evidence that commercial malware detectors are susceptible to these evasion tactics. In this paper, we describe the design and implementation of a malware normalizer ...

  17. Effect of step width manipulation on tibial stress during running.

    Science.gov (United States)

    Meardon, Stacey A; Derrick, Timothy R

    2014-08-22

    Narrow step width has been linked to variables associated with tibial stress fracture. The purpose of this study was to evaluate the effect of step width on bone stresses using a standardized model of the tibia. 15 runners ran at their preferred 5k running velocity in three running conditions, preferred step width (PSW) and PSW±5% of leg length. 10 successful trials of force and 3-D motion data were collected. A combination of inverse dynamics, musculoskeletal modeling and beam theory was used to estimate stresses applied to the tibia using subject-specific anthropometrics and motion data. The tibia was modeled as a hollow ellipse. Multivariate analysis revealed that tibial stresses at the distal 1/3 of the tibia differed with step width manipulation (p=0.002). Compression on the posterior and medial aspect of the tibia was inversely related to step width such that as step width increased, compression on the surface of tibia decreased (linear trend p=0.036 and 0.003). Similarly, tension on the anterior surface of the tibia decreased as step width increased (linear trend p=0.029). Widening step width linearly reduced shear stress at all 4 sites (pstresses experienced by the tibia during running were influenced by step width when using a standardized model of the tibia. Wider step widths were generally associated with reduced loading of the tibia and may benefit runners at risk of or experiencing stress injury at the tibia, especially if they present with a crossover running style. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. A compact plasma pre-ionized TEA-CO2 laser pulse clipper for material processing

    Science.gov (United States)

    Gasmi, Taieb

    2017-08-01

    An extra-laser cavity CO2-TEA laser pulse clipper using gas breakdown techniques for high spatial resolution material processing and shallow material engraving and drilling processes is presented. Complete extinction of the nitrogen tail, that extends the pulse width, is obtained at pressures from 375 up to 1500 torr for nitrogen and argon gases. Excellent energy stability and pulse repeatability were further enhanced using high voltage assisted preionized plasma gas technique. Experimental data illustrates the direct correlation between laser pulse width and depth of engraving in aluminum and alumina materials.

  19. 4-channel time delayed pulse generator

    International Nuclear Information System (INIS)

    Wetzel, L.F.S.; Rossi, J.O.; Del Bosco, E.

    1987-02-01

    It is described the project of a 4-channel delayed pulse generator employed to trigger the plasma centrifuge experiment of the Laboratorio Associado de Plasmas. The circuit delivers pulses with amplitude of 15V, full width at half maximum of 50μs and rise time of 0.7μs. The maximum time delay is 100ms. There are two channels with a fine adjustment of 0-1ms. The system can be manually or automatically driven. (author) [pt

  20. Pulse pile-up. I: Short pulses

    International Nuclear Information System (INIS)

    Wilkinson, D.H.

    1990-07-01

    The search for rare large pulses against an intense background of smaller ones involves consideration of pulse pile-up. Approximate methods are presented, based on ruin theory, by which the probability of such pile-up may be estimated for pulses of arbitrary form and of arbitrary pulse-height distribution. These methods are checked against cases for which exact solutions are available. The present paper is concerned chiefly with short pulses of finite total duration. (Author) (5 refs., 24 figs.)

  1. Progressive changes in arch width from primary to early mixed dentition period: a longitudinal study.

    Science.gov (United States)

    Sangwan, S; Chawla, H S; Goyal, A; Gauba, K; Mohanty, U

    2011-01-01

    The present study was conducted to evaluate, on a longitudinal basis, the changes in intercanine and intermolar widths form the primary to the early mixed dentition periods. A total of 38 children aged 4-5 years, with normal occlusion without any proximal caries or any dental anomalies, were selected. The impressions were recorded and casts were prepared. Intercanine and intermolar widths were measured on these dental casts with the help of a digital vernier calliper. After 3 years follow-up, the impressions were recorded again and dental casts were prepared. Intercanine and intermolar widths were measured again at this stage and were compared with the baseline data using the paired t-test and the chi square test. There is a significant increase in the intercanine (3.93 + 1.70 mm) and intermolar width (1.49 + 1.77 mm) during the transition period from primary to early mixed dentition in both the arches and both the sexes. The gender-wise comparison showed a greater increase in males than in females, but this was not statistically significant. A thorough knowledge of growth changes during various stages of the mixed dentition period are important for a pediatric dentist to make an accurate diagnosis and treatment planning during preventive and interceptive orthodontics.

  2. Progressive changes in arch width from primary to early mixed dentition period: A longitudinal study

    Directory of Open Access Journals (Sweden)

    S Sangwan

    2011-01-01

    Full Text Available Objective: The present study was conducted to evaluate, on a longitudinal basis, the changes in intercanine and intermolar widths form the primary to the early mixed dentition periods. Materials and Methods: A total of 38 children aged 4-5 years, with normal occlusion without any proximal caries or any dental anomalies, were selected. The impressions were recorded and casts were prepared. Intercanine and intermolar widths were measured on these dental casts with the help of a digital vernier calliper. After 3 years follow-up, the impressions were recorded again and dental casts were prepared. Intercanine and intermolar widths were measured again at this stage and were compared with the baseline data using the paired t-test and the chi square test. Results: There is a significant increase in the intercanine (3.93 + 1.70 mm and intermolar width (1.49 + 1.77 mm during the transition period from primary to early mixed dentition in both the arches and both the sexes. The gender-wise comparison showed a greater increase in males than in females, but this was not statistically significant. Conclusion: A thorough knowledge of growth changes during various stages of the mixed dentition period are important for a pediatric dentist to make an accurate diagnosis and treatment planning during preventive and interceptive orthodontics.

  3. Design of etch holes to compensate spring width loss for reliable resonant frequencies

    International Nuclear Information System (INIS)

    Jang, Yun-Ho; Kim, Jong-Wan; Kim, Yong-Kweon; Kim, Jung-Mu

    2012-01-01

    A pattern width loss during the fabrication of lateral silicon resonators degrades resonant frequency reliability since such a width loss causes the significant deviation of spring stiffness. Here we present a design guide for etch holes to obtain reliable resonant frequencies by controlling etch holes geometries. The new function of an etch hole is to generate the comparable amount of the width loss between springs and etch holes, in turn to minimize the effect of the spring width loss on resonant frequency shift and deviation. An analytic expression reveals that a compensation factor (CF), defined by the circumference (C u ) of a unit etch hole divided by its silicon area (A u ), is a key parameter for reliable frequencies. The protrusive etch holes were proposed and compared with square etch holes to demonstrate the frequency reliability according to CF values and etch hole shapes. The normalized resonant frequency shift and deviation of the protrusive etch hole (−13.0% ± 6.9%) were significantly improved compared to those of a square etch hole with a small CF value (−42.8% ± 14.8%). The proposed design guide based on the CF value and protrusive shapes can be used to achieve reliable resonant frequencies for high performance silicon resonators. (technical note)

  4. Comparisons of stomatal parameters between normal and abnormal ...

    African Journals Online (AJOL)

    ED), guard cell length (GCL) and guard cell width (GCW) of normal and abnormal leaf of Bougainvillea spectabilis Willd were studied. This can be useful for further research of physical mechanism of abnormal leaf. Epidermal cells were ...

  5. Repetitive transcranial magnetic stimulator with controllable pulse parameters

    Science.gov (United States)

    Peterchev, Angel V.; Murphy, David L.; Lisanby, Sarah H.

    2011-06-01

    The characteristics of transcranial magnetic stimulation (TMS) pulses influence the physiological effect of TMS. However, available TMS devices allow very limited adjustment of the pulse parameters. We describe a novel TMS device that uses a circuit topology incorporating two energy storage capacitors and two insulated-gate bipolar transistor (IGBT) modules to generate near-rectangular electric field pulses with adjustable number, polarity, duration, and amplitude of the pulse phases. This controllable pulse parameter TMS (cTMS) device can induce electric field pulses with phase widths of 10-310 µs and positive/negative phase amplitude ratio of 1-56. Compared to conventional monophasic and biphasic TMS, cTMS reduces energy dissipation up to 82% and 57% and decreases coil heating up to 33% and 41%, respectively. We demonstrate repetitive TMS trains of 3000 pulses at frequencies up to 50 Hz with electric field pulse amplitude and width variability less than the measurement resolution (1.7% and 1%, respectively). Offering flexible pulse parameter adjustment and reduced power consumption and coil heating, cTMS enhances existing TMS paradigms, enables novel research applications and could lead to clinical applications with potentially enhanced potency.

  6. Anomalous normal mode oscillations in semiconductor microcavities

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H. [Univ. of Oregon, Eugene, OR (United States). Dept. of Physics; Hou, H.Q.; Hammons, B.E. [Sandia National Labs., Albuquerque, NM (United States)

    1997-04-01

    Semiconductor microcavities as a composite exciton-cavity system can be characterized by two normal modes. Under an impulsive excitation by a short laser pulse, optical polarizations associated with the two normal modes have a {pi} phase difference. The total induced optical polarization is then expected to exhibit a sin{sup 2}({Omega}t)-like oscillation where 2{Omega} is the normal mode splitting, reflecting a coherent energy exchange between the exciton and cavity. In this paper the authors present experimental studies of normal mode oscillations using three-pulse transient four wave mixing (FWM). The result reveals surprisingly that when the cavity is tuned far below the exciton resonance, normal mode oscillation in the polarization is cos{sup 2}({Omega}t)-like, in contrast to what is expected form the simple normal mode model. This anomalous normal mode oscillation reflects the important role of virtual excitation of electronic states in semiconductor microcavities.

  7. Normal accidents

    International Nuclear Information System (INIS)

    Perrow, C.

    1989-01-01

    The author has chosen numerous concrete examples to illustrate the hazardousness inherent in high-risk technologies. Starting with the TMI reactor accident in 1979, he shows that it is not only the nuclear energy sector that bears the risk of 'normal accidents', but also quite a number of other technologies and industrial sectors, or research fields. The author refers to the petrochemical industry, shipping, air traffic, large dams, mining activities, and genetic engineering, showing that due to the complexity of the systems and their manifold, rapidly interacting processes, accidents happen that cannot be thoroughly calculated, and hence are unavoidable. (orig./HP) [de

  8. A high pulsed power supply system designed for pulsed high magnetic field

    International Nuclear Information System (INIS)

    Liu Kefu; Wang Shaorong; Zhong Heqing; Xu Yan; Pan Yuan

    2008-01-01

    This paper introduces the design of high pulsed power supply system for producing pulsed high magnetic field up to 70 T. This system consists of 58 sets of 55 μF of capacitor bank which provides 1.0 MJ energy storage. A set of vacuum closing switch is chosen as main switch for energy discharge into magnetic coil. A crowbar circuit with high power diodes in series with resistor is used to absorb the redundant energy and adjust pulse width. The resistance of magnetic coil changing with current is deduced by energy balance equations. A capacitor-charging power supply using a series-resonant, constant on-time variable frequency control, and zero-current switching charges the capacitor bank in one minute time with high efficiency. The pulsed power supply provides adjustable current and pulse width with 30 kA peak and 30 ms maximum. The primary experiments demonstrate the system reliability. This work provides an engineering guidance for future development of pulsed high magnetic field. (authors)

  9. Frequency Properties Research of Elevator Drive System with Direct Torque Control-Pulse with Modulation

    Directory of Open Access Journals (Sweden)

    A. S. Koval

    2008-01-01

    Full Text Available In the article problems of frequency properties research for electric drive system with direct torque control and pulse width modulator are described. The mathematical description of elevator is present. Simplified mathematical description of direct torque control - pulse width modulator electric drive system is shown. Transfer functions for torque and speed loops are determined. Logarithmic frequency characteristics are computed. Damping properties of elevator drive system are estimated.

  10. Design of electron detection system for pulse electron irradiator

    International Nuclear Information System (INIS)

    Anjar Anggraini H; Agus Purwadi; Lely Susita RM; Bambang Siswanto; Agus Wijayanto

    2016-01-01

    Design of electron detection system for pulse electron irradiator has been conducted on the Plasma Cathode Electron Source by Rogowski coil technique. Rogowski coil has ability to capture the induced magnetic field of the electric current, subsequent induced magnetic field will provide voltage after passing integrator. This diagnostic used combination of copper wire, ferrite and RC integrator. The design depends on the pulse width and the value of plasma current that passes through the coil, thus the number of windings, coil area and integrator can be designed. For plasma spots current of IDPS expected to be 10 A and pulse width 10 μs the Rogowski coil using MnZn ferrite with inductance L = 0.275 mH and permeability μr = 200 H/m. For the current of plasma arc ADPS expected to be 100 A and pulse width 100 μs by using inductance L=1.9634 mH and permeability μr = 6256 H/m. Electron current in extraction system expected to be 30 A and pulse width 100 μs the Rogowski coil using inductance L=51.749 mH and permeability μr= 4987 H/m. Design integrator used is the type of RC integrator. (author)

  11. The effect of scattering interference term on the practical width

    International Nuclear Information System (INIS)

    Martins do Amaral, C.; Martinez, A.S.

    2001-01-01

    The practical width Γ p has an important application in the characterization of the resonance type for the calculation of neutron average cross sections. Previous treatments ignore the interference term χζ,x for the Doppler broadening function in the practical width calculation. In the present paper, a rational approximation for the χζ,x function is derived, using a modified asymptotic Pade method. A new approximation for Γ p is obtained. The results which are presented here provide evidence that the practical width as a function of temperature varies considerably with the inclusion of the interference term χζ,x

  12. Nightside studies of coherent HF Radar spectral width behaviour

    Directory of Open Access Journals (Sweden)

    E. E. Woodfield

    2002-09-01

    Full Text Available A previous case study found a relationship between high spectral width measured by the CUTLASS Finland HF radar and elevated electron temperatures observed by the EISCAT and ESR incoherent scatter radars in the post-midnight sector of magnetic local time. This paper expands that work by briefly re-examining that interval and looking in depth at two further case studies. In all three cases a region of high HF spectral width (>200 ms-1 exists poleward of a region of low HF spectral width (<200 ms-1. Each case, however, occurs under quite different geomagnetic conditions. The original case study occurred during an interval with no observed electrojet activity, the second study during a transition from quiet to active conditions with a clear band of ion frictional heating indicating the location of the flow reversal boundary, and the third during an isolated sub-storm. These case studies indicate that the relationship between elevated electron temperature and high HF radar spectral width appears on closed field lines after 03:00 magnetic local time (MLT on the nightside. It is not clear whether the same relationship would hold on open field lines, since our analysis of this relationship is restricted in latitude. We find two important properties of high spectral width data on the nightside. Firstly the high spectral width values occur on both open and closed field lines, and secondly that the power spectra which exhibit high widths are both single-peak and multiple-peak. In general the regions of high spectral width (>200 ms-1 have more multiple-peak spectra than the regions of low spectral widths whilst still maintaining a majority of single-peak spectra. We also find that the region of ion frictional heating is collocated with many multiple-peak HF spectra. Several mechanisms for the generation of high spectral width have been proposed which would produce multiple-peak spectra, these are discussed in relation to the data presented here. Since the

  13. Influence of electrical sheet width on dynamic magnetic properties

    CERN Document Server

    Chevalier, T; Cornut, B

    2000-01-01

    Effects of the width of electrical steel sheets on dynamic magnetic properties are investigated by solving diffusion equation on the cross-section of the sheet. Linear and non-linear cases are studied, and are compared with measurement on Epstein frame. For the first one an analytical solution is found, while for the second, a 2D finite element simulation is achieved. The influence of width is highlighted for a width thickness ratio lower than 10. It is shown that the behaviour modification in such cases is conditioned by the excitation signal waveform, amplitude and also frequency.

  14. Nightside studies of coherent HF Radar spectral width behaviour

    Directory of Open Access Journals (Sweden)

    E. E. Woodfield

    Full Text Available A previous case study found a relationship between high spectral width measured by the CUTLASS Finland HF radar and elevated electron temperatures observed by the EISCAT and ESR incoherent scatter radars in the post-midnight sector of magnetic local time. This paper expands that work by briefly re-examining that interval and looking in depth at two further case studies. In all three cases a region of high HF spectral width (>200 ms-1 exists poleward of a region of low HF spectral width (<200 ms-1. Each case, however, occurs under quite different geomagnetic conditions. The original case study occurred during an interval with no observed electrojet activity, the second study during a transition from quiet to active conditions with a clear band of ion frictional heating indicating the location of the flow reversal boundary, and the third during an isolated sub-storm. These case studies indicate that the relationship between elevated electron temperature and high HF radar spectral width appears on closed field lines after 03:00 magnetic local time (MLT on the nightside. It is not clear whether the same relationship would hold on open field lines, since our analysis of this relationship is restricted in latitude. We find two important properties of high spectral width data on the nightside. Firstly the high spectral width values occur on both open and closed field lines, and secondly that the power spectra which exhibit high widths are both single-peak and multiple-peak. In general the regions of high spectral width (>200 ms-1 have more multiple-peak spectra than the regions of low spectral widths whilst still maintaining a majority of single-peak spectra. We also find that the region of ion frictional heating is collocated with many multiple-peak HF spectra. Several mechanisms for the generation of high spectral width have been proposed which would produce multiple-peak spectra, these are discussed in relation to

  15. A Novel Subnanosecond Monocycle Pulse Generator for UWB Radar Applications

    Directory of Open Access Journals (Sweden)

    Xinfan Xia

    2014-01-01

    Full Text Available A novel ultra-wideband (UWB monocycle pulse generator with good performance is designed and demonstrated in this paper. It contains a power supply circuit, a pulse drive circuit, a unique pulse forming circuit, and a novel monopolar-to-monocycle pulse transition circuit. The drive circuit employs wideband bipolar junction transistors (BJTs and linear power amplifier transistor to produce a high amplitude drive pulse, and the pulse forming circuit uses the transition characteristics of step recovery diode (SRD effectively to produce a negative narrow pulse. At last, the monocycle pulse forming circuit utilizes a novel inductance L short-circuited stub to generate the monocycle pulse directly. Measurement results show that the waveform of the generated monocycle pulses is over 76 V in peak-to-peak amplitude and 3.2 ns in pulse full-width. These characteristics of the monocycle pulse are advantageous for obtaining long detection range and high resolution, when it is applied to ultra-wideband radar applications.

  16. A compact nanosecond pulse generator for DBD tube characterization

    Science.gov (United States)

    Rai, S. K.; Dhakar, A. K.; Pal, U. N.

    2018-03-01

    High voltage pulses of very short duration and fast rise time are required for generating uniform and diffuse plasma under various operating conditions. Dielectric Barrier Discharge (DBD) has been generated by high voltage pulses of short duration and fast rise time to produce diffuse plasma in the discharge gap. The high voltage pulse power generators have been chosen according to the requirement for the DBD applications. In this paper, a compact solid-state unipolar pulse generator has been constructed for characterization of DBD plasma. This pulsar is designed to provide repetitive pulses of 315 ns pulse width, pulse amplitude up to 5 kV, and frequency variation up to 10 kHz. The amplitude of the output pulse depends on the dc input voltage. The output frequency has been varied by changing the trigger pulse frequency. The pulsar is capable of generating pulses of positive or negative polarity by changing the polarity of pulse transformer's secondary. Uniform and stable homogeneous dielectric barrier discharge plasma has been produced successfully in a xenon DBD tube at 400-mbar pressure using the developed high voltage pulse generator.

  17. Improved stabilization scheme for computerized pulse-height analyzers

    International Nuclear Information System (INIS)

    Cohn, C.E.

    1982-01-01

    A stabilization scheme has been adapted from a 24-bit to a 16-bit computer. A precision pulse generator produces tagged reference pulses alternately of high and low amplitude. Gain and zero corrections are obtained from these and applied to each normal event. Provisions are made to make the system robust against pileup corruption of the reference pulses. (orig.)

  18. An injection seeded single frequency Nd:YAG Q-switched laser with precisely controllable laser pulse firing time

    Science.gov (United States)

    Wu, Frank F.; Khizhnyak, Anatoliy; Markov, Vladimir

    2010-02-01

    We have realized a single frequency Q-switched Nd:YAG laser with precisely controllable lasing time and thus enabled synchronization of multi-laser systems. The use of injection seeding to the slave ring oscillator results in unidirectional Q-switched laser oscillation with suppression of bidirectional Q-switched oscillation that otherwise would be initiated from spontaneous emission if the seeding laser is not present. Under normal condition, the cavity is high in loss during the pumping period; then a Pockels cell opens the cavity to form the pulse build up, with a second Pockels cell to perform cavity dumping, generating the Q-switched pulse output with optimized characteristics. The two Pockels cells can be replaced by a single unit if an adjustable gated electrical pulse is applied to the Pockels cell in which the pulse front is used to open the cavity and the falling edge to dump the laser pulse. Proper selection of the pump parameters and Pockels-cell gating enables operation of the system in a mode in which the Q-switched pulse can be formed only under the seeding condition. The advantage of the realized regime is in stable laser operation with no need in adjustment of the seeded light wavelength and the mode of the cavity. It is found that the frequency of the Q-switched laser radiation matches well to the injected seeded laser mode. By using two-stage amplifiers, an output energy better than 300 mJ has been achieved in MOPA configuration without active control of the cavity length and with pulse width adjustability from several nanoseconds to 20 ns. The Q-switched oscillator operates not only at precisely controlled firing time but also can be tuned over wide range. This will enable multi-laser systems synchronization and frequency locking down each other if necessary.

  19. 2-Dimension pulse shape discriminator for phoswich detector based on FPGA

    International Nuclear Information System (INIS)

    Ji Jianfeng; Liu Congzhan; Zhang Zhi

    2011-01-01

    It improves the data acquire system for the pulse signal based on digital front-rear pulse shape discrimination system. It adds pulse width information into the pulse's data package. Base on this, we divide the pulse event process into two process, on line coast process and offline accurate process: the online process sets a big threshold, just save the data of the event below this threshold; the offline process uses the acquired data, get the pulse amplitude and pulse width, and then according the spectrum's real shape, set the accurate threshold. this design resolves the problem that the detector's decay time change with the temperature; at the same time, it can correct the system's distortion when the input signal at small amplitude, improves the discrimination system's accuracy. (authors)

  20. High Energy, Short Pulse Fiber Injection Lasers at Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, J W; Messerly, M J; Phan, H H; Crane, J K; Beach, R J; Siders, C W; Barty, C J

    2008-09-10

    A short pulse fiber injection laser for the Advanced Radiographic Capability (ARC) on the National Ignition Facility (NIF) has been developed at Lawrence Livermore National Laboratory (LLNL). This system produces 100 {micro}J pulses with 5 nm of bandwidth centered at 1053 nm. The pulses are stretched to 2.5 ns and have been recompressed to sub-ps pulse widths. A key feature of the system is that the pre-pulse power contrast ratio exceeds 80 dB. The system can also precisely adjust the final recompressed pulse width and timing and has been designed for reliable, hands free operation. The key challenges in constructing this system were control of the signal to noise ratio, dispersion management and managing the impact of self phase modulation on the chirped pulse.

  1. Optimized transmission-line impedance transformers for petawatt-class pulsed-power accelerators

    Directory of Open Access Journals (Sweden)

    D. R. Welch

    2008-03-01

    Full Text Available We have developed 1D analytic and 2D fully electromagnetic models of radial transmission-line impedance transformers. The models have been used to quantify the power-transport efficiency and pulse sharpening of such transformers as a function of voltage pulse width and impedance profile. For the cases considered, we find that in the limit as Γ→0 (where Γ is the ratio of the pulse width to the one-way transit time of the transformer, the transport efficiency is maximized when the impedance profile is exponential. As Γ increases from zero, the optimum profile gradually deviates from an exponential. A numerical procedure is presented that determines the optimum profile for a given pulse shape and width. The procedure can be applied to optimize the design of impedance transformers used in petawatt-class pulsed-power accelerators.

  2. Reconstructing Normality

    DEFF Research Database (Denmark)

    Gildberg, Frederik Alkier; Bradley, Stephen K.; Fristed, Peter Billeskov

    2012-01-01

    Forensic psychiatry is an area of priority for the Danish Government. As the field expands, this calls for increased knowledge about mental health nursing practice, as this is part of the forensic psychiatry treatment offered. However, only sparse research exists in this area. The aim of this study...... was to investigate the characteristics of forensic mental health nursing staff interaction with forensic mental health inpatients and to explore how staff give meaning to these interactions. The project included 32 forensic mental health staff members, with over 307 hours of participant observations, 48 informal....... The intention is to establish a trusting relationship to form behaviour and perceptual-corrective care, which is characterized by staff's endeavours to change, halt, or support the patient's behaviour or perception in relation to staff's perception of normality. The intention is to support and teach the patient...

  3. Pursuing Normality

    DEFF Research Database (Denmark)

    Madsen, Louise Sofia; Handberg, Charlotte

    2018-01-01

    implying an influence on whether to participate in cancer survivorship care programs. Because of "pursuing normality," 8 of 9 participants opted out of cancer survivorship care programming due to prospects of "being cured" and perceptions of cancer survivorship care as "a continuation of the disease......BACKGROUND: The present study explored the reflections on cancer survivorship care of lymphoma survivors in active treatment. Lymphoma survivors have survivorship care needs, yet their participation in cancer survivorship care programs is still reported as low. OBJECTIVE: The aim of this study...... was to understand the reflections on cancer survivorship care of lymphoma survivors to aid the future planning of cancer survivorship care and overcome barriers to participation. METHODS: Data were generated in a hematological ward during 4 months of ethnographic fieldwork, including participant observation and 46...

  4. SLAC pulsed X-ray facility

    Science.gov (United States)

    Ipe, N. E.; McCall, R. C.; Baker, E. D.

    1986-05-01

    The Stanford Linear Accelerator Center (SLAC) operates a high energy (up to 33 GeV) linear accelerator delivering pulses up to a few microseconds wide. The pulsed nature of the electron beam creates problems in the detection and measurement of radiation both from the accelerator beam and the klystrons that provide the RF power for the accelerator. Hence, a pulsed X-ray facility has been built at SLAC mainly for the purpose of testing the response of different radiation detection instruments to pulsed radiation fields. The X-ray tube consists of an electron gun with a control grid. This provides a stream of pulsed electrons that can be accelerated towards a confined target-window. The window is made up of aluminum 0.051 cm (20 mils) thick, plated on the vacuum side with a layer of gold 0.0006 cm (1/4 mil) thick. The frequency of electron pulses can be varied by an internal pulser from 60 to 360 pulses per second with pulse widths of 360 ns to 5 ms. The pulse amplitude can be varied over a wide range of currents. An external pulser can be used to obtain other frequencies or special pulse shapes. The voltage across the gun can be varied from 0 to 100 kV. The major part of the X-ray tube is enclosed in a large walk-in-cabinet made of 1.9 cm (3/4 in) plywood and lined with 0.32 cm (1/8 in) lead to make a very versatile facility.

  5. SLAC pulsed x-ray facility

    International Nuclear Information System (INIS)

    Ipe, N.E.; McCall, R.C.; Baker, E.D.

    1986-05-01

    The Stanford Linear Accelerator Center (SLAC) operates a high energy (up to 33 GeV) linear accelerator delivering pulses up to a few microseconds wide. The pulsed nature of the electron beam creates problems in the detection and measurement of radiation both from the accelerator beam and the klystrons that provide the rf power for the accelerator. Hence, a pulsed x-ray facility has been built at SLAC mainly for the purpose of testing the response of different radiation detection instruments to pulsed radiation fields. The x-ray tube consists of an electron gun with a control grid. This provides a stream of pulsed electrons that can be accelerated towards a confined target-window. The window is made up of aluminium 0.051 cm (20 mils) thick, plated on the vacuum side with a layer of gold 0.0006 cm (1/4 mil) thick. The frequency of electron pulses can be varied by an internal pulser from 60 to 360 pulses per second with pulse widths of 360 ns to 5 μs. The pulse amplitude can be varied over a wide range of currents. An external pulser can be used to obtain other frequencies or special pulse shapes. The voltage across the gun can be varied from 0 to 100 kV. The major part of the x-ray tube is enclosed in a large walk-in-cabinet made of 1.9 cm (3/4 in) plywood and lined with 0.32 cm (1/8 in) lead to make a very versatile facility. 3 refs., 5 figs

  6. Relationship between width of greater trochanters and width of iliac wings in tronchanteric bursitis.

    Science.gov (United States)

    Viradia, Neal K; Berger, Alex A; Dahners, Laurence E

    2011-09-01

    Trochanteric bursitis is a common disorder that is characterized by inflammation of the bursa, superficial to the greater trochanter of the femur, leading to pain in the lateral hip, and often occurs because of acute trauma or repetitive friction involving the iliotibial band, the greater trochanter, and the bursa. In the study reported here, we hypothesized that the increased incidence of bursitis may be the result of the increased prominence of the trochanter in relation to the wings of the iliac crest. Distances between the outermost edges of trochanters and iliac wings were measured in 202 patients from the University of North Carolina Health Care System-101 without a known diagnosis and 101 with a clinical diagnosis of trochanteric bursitis. To determine significance, t tests for nonpaired data were used. Mean (SD) difference between trochanter and iliac wing widths was 28 (20) mm in the group diagnosed with trochanteric bursitis and 17 (18) mm in the control group. The difference between the groups in this regard was significant (Pbursitis group and 1.05 (.06) in the control group. The difference between these groups was significant (Pbursitis.

  7. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... experimental investigations of the augmentation of turbulent flow heat transfer in a horizontal tube by means of varying width twisted tape inserts with air as the working fluid.

  8. A fast integrated discriminator with continuously variable width

    International Nuclear Information System (INIS)

    Borghesi, A.; Goggi, G.; Nardo, R.

    1976-01-01

    A simple dc-coupled discriminator with fast switching characteristics has been realized. Both input threshold and output width are continuously variable; the ECL design allows high speed and high density with ample fanout. (Auth.)

  9. Line Width Recovery after Vectorization of Engineering Drawings

    Directory of Open Access Journals (Sweden)

    Gramblička Matúš

    2016-12-01

    Full Text Available Vectorization is the conversion process of a raster image representation into a vector representation. The contemporary commercial vectorization software applications do not provide sufficiently high quality outputs for such images as do mechanical engineering drawings. Line width preservation is one of the problems. There are applications which need to know the line width after vectorization because this line attribute carries the important semantic information for the next 3D model generation. This article describes the algorithm that is able to recover line width of individual lines in the vectorized engineering drawings. Two approaches are proposed, one examines the line width at three points, whereas the second uses a variable number of points depending on the line length. The algorithm is tested on real mechanical engineering drawings.

  10. Estimates for the widths of weighted Sobolev classes

    International Nuclear Information System (INIS)

    Vasil'eva, Anastasia A

    2010-01-01

    Estimates for the Kolmogorov widths in the L q,v -metric of weighted Sobolev classes as well as for the approximation numbers of the corresponding embedding operators are found. Bibliography: 33 titles.

  11. Toeless pulse shaping with a single delay-line network

    International Nuclear Information System (INIS)

    Tauhata, L.; Binns, D.C.

    1976-04-01

    New unipolar delay-line clippers producing negligible cancellation remnant have been developed. Near perfect clipping is achieved using a combination of several types of coaxial cable tranformers working as a phase inverter, a new pulse adder, or an impedance transformer. Only passive elements are used in the bridge network. The construction is simple and the performance is extremely stable and wide in dynamic range and frequency band width. Completely symmetrical bipolar pulses are also easily obtained using this technique

  12. Assessment and mitigation of electromagnetic pulse (EMP) impacts at short-pulse laser facilities

    International Nuclear Information System (INIS)

    Brown, C G Jr; Bond, E; Clancy, T; Dangi, S; Eder, D C; Ferguson, W; Kimbrough, J; Throop, A

    2010-01-01

    The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

  13. Differences in the H-mode pedestal width of temperature and density

    International Nuclear Information System (INIS)

    Schneider, P A; Wolfrum, E; Günter, S; Kurzan, B; Lackner, K; Zohm, H; Groebner, R J; Osborne, T H; Ferron, J R; Snyder, P B; Beurskens, M N A; Dunne, M G

    2012-01-01

    A pedestal database was built using data from type-I ELMy H-modes of ASDEX Upgrade, DIII-D and JET. ELM synchronized pedestal data were analysed with the two-line method. The two-line method is a bilinear fit which shows better reproducibility of pedestal parameters than a modified hyperbolic tangent fit. This was tested with simulated and experimental data. The influence of the equilibrium reconstruction on pedestal parameters was investigated with sophisticated reconstructions from CLISTE and EFIT including edge kinetic profiles. No systematic deviation between the codes could be observed. The flux coordinate system is influenced by machine size, poloidal field and plasma shape. This will change the representation of the width in different coordinates, in particular, the two normalized coordinates Ψ N and r/a show a very different dependence on the plasma shape. The scalings derived for the pedestal width, Δ, of all machines suggest a different scaling for the electron temperature and the electron density. Both cases show similar dependence with machine size, poloidal magnetic field and pedestal electron temperature and density. The influence of ion temperature and toroidal magnetic field is different on each of Δ T e and Δ n e . In dimensionless form the density pedestal width in Ψ N scales with ρ 0.6 i* , the temperature pedestal width with β p,ped 0.5 . Both widths also show a strong correlation with the plasma shape. The shape dependence originates from the coordinate transformation and is not visible in real space. The presented scalings predict that in ITER the temperature pedestal will be appreciably wider than the density pedestal. (paper)

  14. The width of the giant dipole resonance at finite temperature

    International Nuclear Information System (INIS)

    Mau, N.V.

    1992-01-01

    A method is proposed to evaluate the effect of the change of the Fermi sea on the width of the giant dipole resonance at finite temperature. In a schematic model it is found that, indeed, in 208 Pb the width increases very sharply up to about T=4 MeV but shows a much weaker variation for higher temperature. (author) 26 refs., 7 figs., 2 tabs

  15. SM Higgs decay branching ratios and total Higgs width

    CERN Multimedia

    Daniel Denegri

    2001-01-01

    Upper: Higgs decay ratios as a function of Higgs mass. The largest branching ratio is not necessarily the most usefull one. The most usefull ones are gamma gamma bbar ZZ and WW as in those modes latter signal to background ratios can be achieved. Lower: Total Higgs decay width versus Higgs mass. At low masses the natural width is extremely small, thus observability depends on instrumental resolution primarily.

  16. Estimating the Spectral Width of a Narrowband Optical Signal

    DEFF Research Database (Denmark)

    Lading, Lars; Skov Jensen, A.

    1980-01-01

    Methods for estimating the spectral width of a narrowband optical signal are investigated. Spectral analysis and Fourier spectroscopy are compared. Optimum and close-to-optimum estimators are developed under the constraint of having only one photodetector.......Methods for estimating the spectral width of a narrowband optical signal are investigated. Spectral analysis and Fourier spectroscopy are compared. Optimum and close-to-optimum estimators are developed under the constraint of having only one photodetector....

  17. Correlations for reduced-width amplitudes in 49V

    International Nuclear Information System (INIS)

    Chou, B.H.; Mitchell, G.E.; Bilpuch, E.G.; Westerfeldt, C.R.

    1980-01-01

    Measurement of the relative sign of inelastic proton-channel amplitudes permits the determination of amplitude correlations. Data were obtained for 45 5/2 + resonances in 49 V. Although the reduced widths in each channel followed a Porter-Thomas distribution, large amplitude correlations were observed. The results are compared with the reduced-width--amplitude distribution of Krieger and Porter. This is the first direct test of the Krieger-Porter distribution

  18. Quantum numbers and decay widths of the psi (3684)

    International Nuclear Information System (INIS)

    Luth, V.; Boyarski, A.M.; Lynch, H.L.; Breidenbach, M.; Bulos, F.; Feldman, G.J.; Fryberger, D.; Hanson, G.; Hartill, D.L.; Jean-Marie, B.; Larsen, R.R.; Luke, D.; Morehouse, C.C.; Paterson, J.M.; Perl, M.L.; Pun, T.P.; Rapidis, P.; Richter, B.; Schwitters, R.F.; Tanenbaum, W.; Vannucci, F.; Abrams, G.S.; Chinowsky, W.; Friedberg, C.E.; Goldhaber, G.; Kadyk, J.A.; Litke, A.M.; Lulu, B.A.; Pierre, F.M.; Sadoulet, B.; Trilling, G.H.; Whitaker, J.S.; Winkelmann, F.C.; Wiss, J.E.

    1975-01-01

    Cross sections for e + e - →hadrons, e + e - , and μ + μ - near 3684 MeV are presented. The psi(3684) resonance is established as having the assignment J/sup PC/=1 -- . The mass is 3684+-5 MeV. The partial width for decay to electrons is GAMMA/sube/=2.1+-0.3 keV and the total width is GAMMA=228+-56 keV

  19. In-medium ϕ meson width extracted from proton-nucleus collisions

    Directory of Open Access Journals (Sweden)

    Roca L.

    2012-12-01

    Full Text Available The inclusive production of ϕ mesons at small angles in proton collisions with C, Cu, Ag, and Au targets has been measured at an incident energy of 2.83 GeV at the ANKE-COSY facility. The ϕ mesons were registered via the ϕ → K+K− decay. The momentum dependence of the nuclear transparency ratio, the in-medium ϕ width, and the differential cross section for ϕ production have been determined in the momentum region pϕ = 0.6 − 1.6 GeV/c. Comparison with different model calculations suggests a significant broadening of the in-medium ϕ width for normal nuclear density with evidence for a momentum dependence.

  20. High power coupler issues in normal conducting and superconducting accelerator applications

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, H. [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-02-01

    The ceramic material (Al{sub 2}O{sub 3}) commonly used for the klystron output coupler in normal conducting, and for an input coupler to superconducting cavities is one of the most troublesome parts in accelerator applications. But the performance can be improved very much by starting with high purity (>99.9%) alumina powder of controlled grain-size (0.1-0.5-{mu}m), and reducing the magnesium (Mg) sintering-binder to lower the dielectric loss to the order of 10{sup -4} at S-band frequencies. It has been confirmed that the new ceramic can stand a peak S-band frequency rf power of up to 300 MW and 2.5 {mu}sec pulse width. (author)

  1. Silicon structuring by etching with liquid chlorine and fluorine precursors using femtosecond laser pulses

    International Nuclear Information System (INIS)

    Radu, C.; Simion, S.; Zamfirescu, M.; Ulmeanu, M.; Enculescu, M.; Radoiu, M.

    2011-01-01

    The aim of this study is to investigate the micrometer and submicrometer scale structuring of silicon by liquid chlorine and fluorine precursors with 200 fs laser pulses working at both fundamental (775 nm) and frequency doubled (387 nm) wavelengths. The silicon surface was irradiated at normal incidence by immersing the Si (111) substrates in a glass container filled with liquid chlorine (CCl 4 ) and fluorine (C 2 Cl 3 F 3 ) precursors. We report that silicon surfaces develop an array of spikes with single step irradiation processes at 775 nm and equally at 387 nm. When irradiating the Si surface with 400 pulses at 330 mJ/cm 2 laser fluence and a 775 nm wavelength, the average height of the formed Si spikes in the case of fluorine precursors is 4.2 μm, with a full width at half maximum of 890 nm. At the same irradiation wavelength chlorine precursors develop Si spikes 4 μm in height and with a full width at half maximum of 2.3 μm with irradiation of 700 pulses at 560 mJ/cm 2 laser fluence. Well ordered areas of submicrometer spikes with an average height of about 500 nm and a width of 300 nm have been created by irradiation at 387 nm by chlorine precursors, whereas the fluorine precursors fabricate spikes with an average height of 700 nm and a width of about 200 nm. Atomic force microscopy and scanning electron microscopy of the surface show that the formation of the micrometer and sub-micrometer spikes involves a combination of capillary waves on the molten silicon surface and laser-induced etching of silicon, at both 775 nm and 387 nm wavelength irradiation. The energy-dispersive x-ray measurements indicate the presence of chlorine and fluorine precursors on the structured surface. The fluorine precursors create a more ordered area of Si spikes at both micrometer and sub-micrometer scales. The potential use of patterned Si substrates with gradient topography as model scaffolds for the systematic exploration of the role of 3D micro/nano morphology on cell

  2. Stieltjes-moment-theory technique for calculating resonance width's

    International Nuclear Information System (INIS)

    Hazi, A.U.

    1978-12-01

    A recently developed method for calculating the widths of atomic and molecular resonances is reviewed. The method is based on the golden-rule definition of the resonance width, GAMMA(E). The method uses only square-integrable, L 2 , basis functions to describe both the resonant and the non-resonant parts of the scattering wave function. It employs Stieltjes-moment-theory techniques to extract a continuous approximation for the width discrete representation of the background continuum. Its implementation requires only existing atomic and molecular structure codes. Many-electron effects, such as correlation and polarization, are easily incorporated into the calculation of the width via configuration interaction techniques. Once the width, GAMMA(E), has been determined, the energy shift can be computed by a straightforward evaluation of the required principal-value integral. The main disadvantage of the method is that it provides only the total width of a resonance which decays into more than one channel in a multichannel problem. A review of the various aspects of the theory is given first, and then representative results that have been obtained with this method for several atomic and molecular resonances are discussed. 28 references, 3 figures, 4 tables

  3. Crack width monitoring of concrete structures based on smart film

    International Nuclear Information System (INIS)

    Zhang, Benniu; Wang, Shuliang; Li, Xingxing; Zhang, Xu; Yang, Guang; Qiu, Minfeng

    2014-01-01

    Due to its direct link to structural security, crack width is thought to be one of the most important parameters reflecting damage conditions of concrete structures. However, the width problem is difficult to solve with the existing structural health monitoring methods. In this paper, crack width monitoring by means of adhering enameled copper wires with different ultimate strains on the surface of structures is proposed, based on smart film crack monitoring put forward by the present authors. The basic idea of the proposed method is related to a proportional relationship between the crack width and ultimate strain of the broken wire. Namely, when a certain width of crack passes through the wire, some low ultimate strain wires will be broken and higher ultimate strain wires may stay non-broken until the crack extends to a larger scale. Detection of the copper wire condition as broken or non-broken may indicate the width of the structural crack. Thereafter, a multi-layered stress transfer model and specimen experiment are performed to quantify the relationship. A practical smart film is then redesigned with this idea and applied to Chongqing Jiangjin Yangtze River Bridge. (paper)

  4. Crack width monitoring of concrete structures based on smart film

    Science.gov (United States)

    Zhang, Benniu; Wang, Shuliang; Li, Xingxing; Zhang, Xu; Yang, Guang; Qiu, Minfeng

    2014-04-01

    Due to its direct link to structural security, crack width is thought to be one of the most important parameters reflecting damage conditions of concrete structures. However, the width problem is difficult to solve with the existing structural health monitoring methods. In this paper, crack width monitoring by means of adhering enameled copper wires with different ultimate strains on the surface of structures is proposed, based on smart film crack monitoring put forward by the present authors. The basic idea of the proposed method is related to a proportional relationship between the crack width and ultimate strain of the broken wire. Namely, when a certain width of crack passes through the wire, some low ultimate strain wires will be broken and higher ultimate strain wires may stay non-broken until the crack extends to a larger scale. Detection of the copper wire condition as broken or non-broken may indicate the width of the structural crack. Thereafter, a multi-layered stress transfer model and specimen experiment are performed to quantify the relationship. A practical smart film is then redesigned with this idea and applied to Chongqing Jiangjin Yangtze River Bridge.

  5. Influence of inhomogeneous broadening and deliberately introduced disorder on the width of the lasing spectrum of a quantum dot laser

    Energy Technology Data Exchange (ETDEWEB)

    Korenev, V. V.; Savelyev, A. V., E-mail: savelev@mail.ioffe.ru; Zhukov, A. E.; Omelchenko, A. V.; Maximov, M. V. [Russian Academy of Sciences, Nanotechnology Research and Education Center, St. Petersburg Academic University (Russian Federation)

    2012-05-15

    Analytical expressions for the shape and width of the lasing spectra of a quantum-dot (QD) laser in the case of a small (in comparison with the spectrum width) homogeneous broadening of the QD energy levels have been obtained. It is shown that the dependence of the lasing spectrum width on the output power at room temperature is determined by two dimensionless parameters: the width of QD distribution over the optical-transition energy, normalized to temperature, and the ratio of the optical loss to the maximum gain. The optimal dimensions of the laser active region have been found to obtain a specified width of the emission spectrum at a minimum pump current. The possibility of using multilayer structures with QDs to increase the lasing spectrum's width has been analyzed. It is shown that the use of several arrays of QDs with deliberately variable optical-transition energies leads to broadening of the lasing spectra; some numerical estimates are presented.

  6. Method for integrating a train of fast, nanosecond wide pulses

    International Nuclear Information System (INIS)

    Rose, C.R.

    1987-01-01

    This paper describes a method used to integrate a train of fast, nanosecond wide pulses. The pulses come from current transformers in a RF LINAC beamline. Because they are ac signals and have no dc component, true mathematical integration would yield zero over the pulse train period or an equally erroneous value because of a dc baseline shift. The circuit used to integrate the pulse train first stretches the pulses to 35 ns FWHM. The signals are then fed into a high-speed, precision rectifier which restores a true dc baseline for the following stage - a fast, gated integrator. The rectifier is linear over 55dB in excess of 25 MHz, and the gated integrator is linear over a 60 dB range with input pulse widths as short as 16 ns. The assembled system is linear over 30 dB with a 6 MHz input signal

  7. Effect of laser pulse parameters on the size and fluorescence of nanodiamonds formed upon pulsed-laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Peikang [School of Materials Science and Engineering, North University of China, Taiyuan 030051 (China); Hu, Shengliang, E-mail: hsliang@yeah.net [Key Laboratory of Instrumentation Science and Dynamic Measurement (North University of China), Ministry of Education, National Key Laboratory Science and Technology on Electronic Test and Measurement, Taiyuan 030051 (China); School of Materials Science and Engineering, North University of China, Taiyuan 030051 (China); Zhang, Taiping; Sun, Jing [School of Materials Science and Engineering, Tianjin University, Tianjin 300072 (China); Cao, Shirui [School of Materials Science and Engineering, North University of China, Taiyuan 030051 (China)

    2010-07-15

    The size of nanodiamonds formed upon laser irradiation could be easily controlled over simply adjusting laser pulse parameters. The stable size and structure of nanodiamonds were mostly determined by laser power density and pulse width. Both large nanodiamonds with multiply twinning structure (MTS) and small nanodiamonds with single crystalline structure (SCS) emitted strong visible light after surface passivation, and their fluorescence quantum yield (QY) was 4.6% and 7.1%, respectively.

  8. Effect of laser pulse parameters on the size and fluorescence of nanodiamonds formed upon pulsed-laser irradiation

    International Nuclear Information System (INIS)

    Bai, Peikang; Hu, Shengliang; Zhang, Taiping; Sun, Jing; Cao, Shirui

    2010-01-01

    The size of nanodiamonds formed upon laser irradiation could be easily controlled over simply adjusting laser pulse parameters. The stable size and structure of nanodiamonds were mostly determined by laser power density and pulse width. Both large nanodiamonds with multiply twinning structure (MTS) and small nanodiamonds with single crystalline structure (SCS) emitted strong visible light after surface passivation, and their fluorescence quantum yield (QY) was 4.6% and 7.1%, respectively.

  9. High-energy-throughput pulse compression by off-axis group-delay compensation in a laser-induced filament

    International Nuclear Information System (INIS)

    Voronin, A. A.; Alisauskas, S.; Muecke, O. D.; Pugzlys, A.; Baltuska, A.; Zheltikov, A. M.

    2011-01-01

    Off-axial beam dynamics of ultrashort laser pulses in a filament enable a radical energy-throughput improvement for filamentation-assisted pulse compression. We identify regimes where a weakly diverging wave, produced on the trailing edge of the pulse, catches up with a strongly diverging component, arising in the central part of the pulse, allowing sub-100-fs millijoule infrared laser pulses to be compressed to 20-25-fs pulse widths with energy throughputs in excess of 70%. Theoretical predictions have been verified by experimental results on filamentation-assisted compression of 70-fs, 1.5-μm laser pulses in high-pressure argon.

  10. Annular pulse column development studies

    International Nuclear Information System (INIS)

    Benedict, G.E.

    1980-01-01

    The capacity of critically safe cylindrical pulse columns limits the size of nuclear fuel solvent extraction plants because of the limited cross-sectional area of plutonium, U-235, or U-233 processing columns. Thus, there is a need to increase the cross-sectional area of these columns. This can be accomplished through the use of a column having an annular cross section. The preliminary testing of a pilot-plant-scale annular column has been completed and is reported herein. The column is made from 152.4-mm (6-in.) glass pipe sections with an 89-mm (3.5-in.) o.d. internal tube, giving an annular width of 32-mm (1.25-in.). Louver plates are used to swirl the column contents to prevent channeling of the phases. The data from this testing indicate that this approach can successfully provide larger-cross-section critically safe pulse columns. While the capacity is only 70% of that of a cylindrical column of similar cross section, the efficiency is almost identical to that of a cylindrical column. No evidence was seen of any non-uniform pulsing action from one side of the column to the other

  11. Transient thermal analysis of semiconductor diode lasers under pulsed operation

    Science.gov (United States)

    Veerabathran, G. K.; Sprengel, S.; Karl, S.; Andrejew, A.; Schmeiduch, H.; Amann, M.-C.

    2017-02-01

    Self-heating in semiconductor lasers is often assumed negligible during pulsed operation, provided the pulses are `short'. However, there is no consensus on the upper limit of pulse width for a given device to avoid-self heating. In this paper, we present an experimental and theoretical analysis of the effect of pulse width on laser characteristics. First, a measurement method is introduced to study thermal transients of edge-emitting lasers during pulsed operation. This method can also be applied to lasers that do not operate in continuous-wave mode. Secondly, an analytical thermal model is presented which is used to fit the experimental data to extract important parameters for thermal analysis. Although commercial numerical tools are available for such transient analyses, this model is more suitable for parameter extraction due to its analytical nature. Thirdly, to validate this approach, it was used to study a GaSb-based inter-band laser and an InP-based quantum cascade laser (QCL). The maximum pulse-width for less than 5% error in the measured threshold currents was determined to be 200 and 25 ns for the GaSb-based laser and QCL, respectively.

  12. Multiple current peaks in room-temperature atmospheric pressure homogenous dielectric barrier discharge plasma excited by high-voltage tunable nanosecond pulse in air

    Energy Technology Data Exchange (ETDEWEB)

    Yang, De-Zheng; Wang, Wen-Chun; Zhang, Shuai; Tang, Kai; Liu, Zhi-jie; Wang, Sen [Key Lab of Materials Modification, Dalian University of Technology, Ministry of Education, Dalian 116024 (China)

    2013-05-13

    Room temperature homogenous dielectric barrier discharge plasma with high instantaneous energy efficiency is acquired by using nanosecond pulse voltage with 20-200 ns tunable pulse width. Increasing the voltage pulse width can lead to the generation of regular and stable multiple current peaks in each discharge sequence. When the voltage pulse width is 200 ns, more than 5 organized current peaks can be observed under 26 kV peak voltage. Investigation also shows that the organized multiple current peaks only appear in homogenous discharge mode. When the discharge is filament mode, organized multiple current peaks are replaced by chaotic filament current peaks.

  13. Magnetic resonance imaging in Parkinson's disease; The evaluation of the width of pars compacta on T2 weighted image

    Energy Technology Data Exchange (ETDEWEB)

    Moriwaka, Fumio; Tashiro, Kunio; Itoh, Kazunori; Miyasaka, Kazuo [Hokkaido Univ., Sapporo (Japan). School of Medicine; Hamada, Takeshi

    1992-01-01

    The width of substantia nigra (SN) in 59 cases of idiopathic Parkinson's disease as well as 21 normal controls was analyzed by T2 weighted image (T2WI) of 1.5 Tesla high-field magnetic resonance image (MRI). All patients and controls underwent MRI with the spin-echo sequences used TR/TE: 3000/30 (short TE), and TR/TE: 3000/80 (long TE), in 5-mm-thick volumes. The width between the red nucleus and the cerebral peduncle showing low signal intensity areas was measured as that of SN and its ratio to the distance from the aqueduct to the midline of the cerebral peduncle was also measured. The calculated values of the width of SN and its ratio were analyzed by Mann-Whitney test. The significant reduction in the width of SN and its ratio in Parkinson's disease were disclosed below: the mean calculated values of the width of SN were 2.95{+-}0.51 mm in controls, 2.68{+-}0.99 mm in Parkinson's disase on long TE images (P<0.01), and the mean ratio of the width of SN were 13.58{+-}4.21% in controls, 10.52{+-}3.07% in Parkinson's disease on long TE images (P=0.0002). The narrowing of SN in Parkinson's disease was more prominent in men, and advanced cases with Yahr stage III and IV. Considering that the pars reticulata, which is normally containing iron, shows low signal intensity on long TE images, the width of pars compacta could be measured more precisely on this sequences. The evaluation of the ratio of SN in midbrain on long TE images seemed to be more sensitive than the calculated values in detecting the narrowing of SN and pars compacta in Parkinson's disease. (author).

  14. Picosecond, single pulse electron linear accelerator

    International Nuclear Information System (INIS)

    Kikuchi, Riichi; Kawanishi, Masaharu

    1979-01-01

    The picosecond, single pulse electron linear accelerators, are described, which were installed in the Nuclear Engineering Laboratory of the University of Tokyo and in the Nuclear Radiation Laboratory of the Osaka University. The purpose of the picosecond, single pulse electron linear accelerators is to investigate the very short time reaction of the substances, into which gamma ray or electron beam enters. When the electrons in substances receive radiation energy, the electrons get high kinetic energy, and the energy and the electric charge shift, at last to the quasi-stable state. This transient state can be experimented with these special accelerators very accurately, during picoseconds, raising the accuracy of the time of incidence of radiation and also raising the accuracy of observation time. The outline of these picosecond, single pulse electron linear accelerators of the University of Tokyo and the Osaka University, including the history, the systems and components and the output beam characteristics, are explained. For example, the maximum energy 30 -- 35 MeV, the peak current 1 -- 8 n C, the pulse width 18 -- 40 ps, the pulse repetition rate 200 -- 720 pps, the energy spectrum 1 -- 1.8% and the output beam diameter 2 -- 5 mm are shown as the output beam characteristics of the accelerators in both universities. The investigations utilizing the picosecond single pulse electron linear accelerators, such as the investigation of short life excitation state by pulsed radiation, the dosimetry study of pulsed radiation, and the investigation of the transforming mechanism and the development of the transforming technology from picosecond, single pulse electron beam to X ray, vacuum ultraviolet ray and visual ray, are described. (Nakai, Y.)

  15. Development and testing of pulsed and rotating detonation combustors

    Science.gov (United States)

    St. George, Andrew C.

    analysis approach is developed, which employs cross-correlations to detect the combustor operating state as it evolves during a test. This method enables expedient detection of the operating state from sensors placed outside the combustor, and can also identify and quantify instabilities. An investigation is conducted on a tangentially-injecting initiator tube to characterize the RDC ignition process. Maximum energy deposition for this ignition method is an order of magnitude lower than the required energy for direct initiation, and detonation develops via a deflagration-to-detonation transition process. Stable rotating detonation is preceded by a transitory onset phase with a stochastic duration, which appears to be a function of the reactant injection pressure ratio. Hydrogen-ethylene fuel blends are explored as an interim strategy to transition to stable detonation in ethylene-air mixtures. While moderate hydrogen addition enables stable operation, removal of the supplemental hydrogen triggers instability and failure. Chemical kinetic analysis indicates that elevated reactant pressure is far more significant than hydrogen addition, and suggests that the stabilizing effect of hydrogen is physical, rather than kinetic. The role of kinetic effects (e.g., cell width) is also assessed, using H2-O2-N2 mixtures. Detonation is observed when the normalized channel width exceeds the classical limit of wch/lambda = 0.5, and the number of detonations increases predictably when the detonation perimeter exceeds a critical value.

  16. Effects of toe-in and toe-in with wider step width on level walking knee biomechanics in varus, valgus, and neutral knee alignments.

    Science.gov (United States)

    Bennett, Hunter J; Shen, Guangping; Cates, Harold E; Zhang, Songning

    2017-12-01

    Increased peak external knee adduction moments exist for individuals with knee osteoarthritis and varus knee alignments, compared to healthy and neutrally aligned counterparts. Walking with increased toe-in or increased step width have been individually utilized to successfully reduce 1st and 2nd peak knee adduction moments, respectfully, but have not previously been combined or tested among all alignment groups. The purpose of this study was to compare toe-in only and toe-in with wider step width gait modifications in individuals with neutral, valgus, and varus alignments. Thirty-eight healthy participants with confirmed varus, neutral, or valgus frontal-plane knee alignment through anteroposterior radiographs, performed level walking in normal, toe-in, and toe-in with wider step width gaits. A 3×3 (group×intervention) mixed model repeated measures ANOVA compared alignment groups and gait interventions (pstep width compared to normal gait. The 2nd peak adduction moment was increased in toe-in compared to normal and toe-in with wider step width. The adduction impulse was also reduced in toe-in and toe-in with wider step width compared to normal gait. Peak knee flexion and external rotation moments were increased in toe-in and toe-in with wider step width compared to normal gait. Although the toe-in with wider step width gait seems to be a viable option to reduce peak adduction moments for varus alignments, sagittal, and transverse knee loadings should be monitored when implementing this gait modification strategy. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Study of the electromagnetic characteristics of multiple HTSPPT modules based on the configuration of toroidal structure for inductive pulsed power supply

    Science.gov (United States)

    Zhang, Cunshan; Zheng, Xinxin; Li, Haitao; Li, Zhenmei; Zhang, Tao; Jiao, Can

    2018-04-01

    High temperature superconducting pulsed power transformer (HTSPPT) is an important device for pulsed power supplies. It consists of a superconducting primary and a normal conducting secondary, which is used for energy storage and current amplification. The critical current density, the energy storage, and the coupling coefficient are three main performance indexes. They are affected by the geometry parameters of HTSPPT modules, such as the height and the width of the superconducting coils. In addition, the hoop stress of the HTSPPT coils is limited by the maximum tensile strength of high temperature superconducting (HTS) tapes. In this paper, Bi-2223/Ag HTS tapes are selected as the wire of primary inductor and the toroidal structure model is selected for multiple HTSPPT modules. The relationships between the geometry parameters of HTSPPT modules and the electrical performance are studied.

  18. Pulsed neutron sources for epithermal neutrons

    International Nuclear Information System (INIS)

    Windsor, C.G.

    1978-01-01

    It is shown how accelerator based neutron sources, giving a fast neutron pulse of short duration compared to the neutron moderation time, promise to open up a new field of epithermal neutron scattering. The three principal methods of fast neutron production: electrons, protons and fission boosters will be compared. Pulsed reactors are less suitable for epithermal neutrons and will only be briefly mentioned. The design principle of the target producing fast neutrons, the moderator and reflector to slow them down to epithermal energies, and the cell with its beam tubes and shielding will all be described with examples taken from the new Harwell electron linac to be commissioned in 1978. A general comparison of pulsed neutron performance with reactors is fraught with difficulties but has been attempted. Calculation of the new pulsed source fluxes and pulse widths is now being performed but we have taken the practical course of basing all comparisons on extrapolations from measurements on the old 1958 Harwell electron linac. Comparisons for time-of-flight and crystal monochromator experiments show reactors to be at their best at long wavelengths, at coarse resolution, and for experiments needing a specific incident wavelength. Even existing pulsed sources are shown to compete with the high flux reactors in experiments where the hot neutron flux and the time-of-flight methods can be best exploited. The sources under construction can open a new field of inelastic neutron scattering based on energy transfer up to an electron volt and beyond

  19. Picosecond ion pulses from an EN tandem created by a femtosecond Ti:sapphire laser

    International Nuclear Information System (INIS)

    Carnes, K.D.; Cocke, C.L.; Chang, Z.; Ben-Itzhak, I.; Needham, H.V.; Rankin, A.

    2007-01-01

    As the James R. Macdonald Laboratory at Kansas State University continues its transformation from an ion collisions facility to an ultrafast laser/ion collisions facility, we are looking for novel ways to combine our traditional accelerator expertise with our new laser capabilities. One such combination is to produce picosecond pulses of stripping gas ions in the high energy accelerating tube of our EN tandem by directing ∼100 fs, sub-milliJoule laser pulses up the high energy end of the tandem toward a focusing mirror at the terminal. Ion pulses from both stripping and residual gas have been produced and identified, with pulse widths thus far on the order of a nanosecond. This width represents an upper limit, as it is dominated by pulse-to-pulse jitter in the ion time-of-flight (TOF) and is therefore not a true representation of the actual pulse width. In this paper, we describe the development process and report on the results to date. Conditions limiting the minimum temporal pulse width, such as tandem terminal ripple, thermal motion of the gas and space charge effects, are also outlined

  20. Design and performance of a pulse transformer based on Fe-based nanocrystalline core.

    Science.gov (United States)

    Yi, Liu; Xibo, Feng; Lin, Fuchang

    2011-08-01

    A dry-type pulse transformer based on Fe-based nanocrystalline core with a load of 0.88 nF, output voltage of more than 65 kV, and winding ratio of 46 is designed and constructed. The dynamic characteristics of Fe-based nanocrystalline core under the impulse with the pulse width of several microseconds were studied. The pulse width and incremental flux density have an important effect on the pulse permeability, so the pulse permeability is measured under a certain pulse width and incremental flux density. The minimal volume of the toroidal pulse transformer core is determined by the coupling coefficient, the capacitors of the resonant charging circuit, incremental flux density, and pulse permeability. The factors of the charging time, ratio, and energy transmission efficiency in the resonant charging circuit based on magnetic core-type pulse transformer are analyzed. Experimental results of the pulse transformer are in good agreement with the theoretical calculation. When the primary capacitor is 3.17 μF and charge voltage is 1.8 kV, a voltage across the secondary capacitor of 0.88 nF with peak value of 68.5 kV, rise time (10%-90%) of 1.80 μs is obtained.

  1. Temporal dynamics of high repetition rate pulsed single longitudinal ...

    Indian Academy of Sciences (India)

    ing (GIG) cavity, single-mode dye laser pumped by high repetition rate ... in a high loss cavity, a detailed theoretical study and optimization of cavity ..... rate for high conversion efficiency and longer pulse width of the single-mode dye laser.

  2. The effects of lane width, shoulder width, and road cross-sectional reallocation on drivers' behavioral adaptations.

    Science.gov (United States)

    Mecheri, Sami; Rosey, Florence; Lobjois, Régis

    2017-07-01

    Previous research has shown that lane-width reduction makes drivers operate vehicles closer to the center of the road whereas hard-shoulder widening induces a position farther away from the road's center. The goal of the present driving-simulator study was twofold. First, it was aimed at further investigating the respective effects of lane and shoulder width on in-lane positioning strategies, by examining vehicle distance from the center of the lane. The second aim was to assess the impact on safety of three possible cross-sectional reallocations of the width of the road (i.e., three lane-width reductions with concomitant shoulder widening at a fixed cross-sectional width) as compared to a control road. The results confirmed that lane-width reduction made participants drive closer to the road's center. However, in-lane position was affected differently by lane narrowing, depending on the traffic situation. In the absence of oncoming traffic, lane narrowing gave rise to significant shifts in the car's distance from the lane's center toward the edge line, whereas this distance remained similar across lane widths during traffic periods. When the shoulders were at least 0.50m wide, participants drove farther away from both the road center and the lane center. Road reallocation operations resulted in vehicles positioned farther away from the edge of the road and less swerving behavior, without generating higher driving speeds. Finally, it is argued that road-space reallocation may serve as a good low-cost tool for providing a recovery area for steering errors, without impairing drivers' behavior. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Research of long pulse high current diode radial insulation

    International Nuclear Information System (INIS)

    Tan Jie; Chang Anbi; Hu Kesong; Liu Qingxiang; Ma Qiaosheng; Liu Zhong

    2002-01-01

    A radial insulation structure which is used in long pulse high current diode is introduced. The theory of vacuum flashover and the idea of design are briefly introduced. In the research, cone-shaped insulator was used. The geometry structure parameters were optimized by simulating the static electrical field distribution. Experiment was done on a pulse power source with 200 ns pulse width. The maximum voltage 750 kV was obtained, and the average stand-off electrical field of insulator is about 50 kV/cm

  4. Spatially periodic structures, under femtosecond pulsed excitation of crystals

    International Nuclear Information System (INIS)

    Martynovitch, Evgueni F.; Petite, Guillaume; Dresvianski, Vladimir P.; Starchenko, Anton A.

    2004-01-01

    Measuring the luminescence intensity of specially prepared irradiation defects induced in crystals, we observe that the longitudinal structure of quasi-interferences induced by two orthogonally polarized femtosecond pulses propagating together with different velocities is insensitive to the spatial broadening due to velocity dispersion in the crystals. On the contrary, it does depend on the pulse duration when it is changed by varying the spectral width of the radiation. It thus allows a direct measurement of the coherence time of such pulses. Stability of the axial selectivity is a good sign, taking away a number of serious limitations concerning possible applications

  5. Laser beam diagnostics for kilowatt power pulsed YAG laser

    International Nuclear Information System (INIS)

    Liu, Yi; Leong, Keng H.

    1992-01-01

    There is a growing need for high power YAG laser beam diagnostics with the recent introduction of such lasers in laser material processing. In this paper, we will describe the use of a commercially available laser beam analyzer (Prometec) to profile the laser beam from a 1600 W pulsed Nd:YAG laser that has a 1 mm fiber optic beam delivery system. The selection of laser pulse frequency and pulse width for the measurement is discussed. Laser beam propagation parameters by various optical components such as fibers and lenses can be determined from measurements using this device. The importance of such measurements will be discussed

  6. Generation of a single-cycle optical pulse

    International Nuclear Information System (INIS)

    Shverdin, M.Y.; Walker, D.R.; Yavuz, D.D.; Yin, G.Y.; Harris, S.E.

    2005-01-01

    We make use of coherent control of four-wave mixing to the ultraviolet as a diagnostic and describe the generation of a periodic optical waveform where the spectrum is sufficiently broad that the envelope is approximately a single-cycle in length, and where the temporal shape of this envelope may be synthesized by varying the coefficients of a Fourier series. Specifically, using seven sidebands, we report the generation of a train of single-cycle optical pulses with a pulse width of 1.6 fs, a pulse separation of 11 fs, and a peak power of 1 MW

  7. Form factors and radiation widths of the giant multipole resonances

    International Nuclear Information System (INIS)

    Denisov, V.Yu.

    1990-01-01

    Simple analytic relations for the form factors of inelastic electron scattering in the Born approximation and radiation widths of the isovector and isoscalar giant multipole resonances are derived. The dynamic relationship between the volume and surface density vibrations were taken into account in this calculation. The form factors in the Born approximation were found to be in satisfactory agreement with experimental data in the region of small transferred momenta. The radiation widths of isoscalar multipole resonances increase when the number of nucleons increase as A 1/3 , and for isovector resonances this dependence has the form f(A)A 1/3 , where f(A) is a slowly increasing function of A. Radiation widths well fit the experimental data

  8. Modelling the widths of fission observables in GEF

    Directory of Open Access Journals (Sweden)

    Schmidt K.-H.

    2013-03-01

    Full Text Available The widths of the mass distributions of the different fission channels are traced back to the probability distributions of the corresponding quantum oscillators that are coupled to the heat bath, which is formed by the intrinsic degrees of freedom of the fissioning system under the influence of pairing correlations and shell effects. Following conclusion from stochastic calculations of Adeev and Pashkevich, an early freezing due to dynamical effects is assumed. It is shown that the mass width of the fission channels in low-energy fission is strongly influenced by the zero-point motion of the corresponding quantum oscillator. The observed variation of the mass widths of the asymmetric fission channels with excitation energy is attributed to the energy-dependent properties of the heat bath and not to the population of excited states of the corresponding quantum oscillator.

  9. Fast and Robust Nanocellulose Width Estimation Using Turbidimetry.

    Science.gov (United States)

    Shimizu, Michiko; Saito, Tsuguyuki; Nishiyama, Yoshiharu; Iwamoto, Shinichiro; Yano, Hiroyuki; Isogai, Akira; Endo, Takashi

    2016-10-01

    The dimensions of nanocelluloses are important factors in controlling their material properties. The present study reports a fast and robust method for estimating the widths of individual nanocellulose particles based on the turbidities of their water dispersions. Seven types of nanocellulose, including short and rigid cellulose nanocrystals and long and flexible cellulose nanofibers, are prepared via different processes. Their widths are calculated from the respective turbidity plots of their water dispersions, based on the theory of light scattering by thin and long particles. The turbidity-derived widths of the seven nanocelluloses range from 2 to 10 nm, and show good correlations with the thicknesses of nanocellulose particles spread on flat mica surfaces determined using atomic force microscopy. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Morphodynamics structures induced by variations of the channel width

    Science.gov (United States)

    Duro, Gonzalo; Crosato, Alessandra; Tassi, Pablo

    2014-05-01

    In alluvial channels, forcing effects, such as a longitudinally varying width, can induce the formation of steady bars (Olesen, 1984). The type of bars that form, such as alternate, central or multiple, will mainly depend on the local flow width-to-depth ratio and on upstream conditions (Struiksma et al., 1985). The effects on bar formation of varying the channel width received attention only recently and investigations, based on flume experiments and mathematical modelling, are mostly restricted to small longitudinal sinusoidal variations of the channel width (e.g. Repetto et al., 2002; Wu and Yeh, 2005, Zolezzi et al., 2012; Frascati and Lanzoni, 2013). In this work, we analyze the variations in equilibrium bed topography in a longitudinal width-varying channel with characteristic scales of the Waal River (The Netherlands) using two different 2D depth-averaged morphodynamic models, one based on the Delft3D code and one on Telemac-Mascaret system. In particular, we explore the effects of changing the wavelength of sinusoidal width variations in a straight channel, focusing on the effects of the spatial lag between bar formation and forcing that is observed in numerical models and laboratory experiments (e.g. Crosato et al, 2011). We extend the investigations to finite width variations in which longitudinal changes of the width-to-depth ratio are such that they may affect the type of bars that become unstable (alternate, central or multiple bars). Numerical results are qualitatively validated with field observations and the resulting morphodynamic pattern is compared with the physics-based predictor of river bar modes by Crosato and Mosselman (2009). The numerical models are finally used to analyse the experimental conditions of Wu and Yeh (2005). The study should be seen as merely exploratory. The aim is to investigate possible approaches for future research aiming at assessing the effects of artificial river widening and narrowing to control bar formation in

  11. Analysis on Longitudinal Dose according to Change of Field Width

    International Nuclear Information System (INIS)

    Jung, Won Seok; Shin, Ryung Mi; Oh, Byung Cheon; Jo, Jun Young; Kim, Gi Chul; Choi, Tae Gu; Back, Jong Geal

    2011-01-01

    To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  12. Effects of injection nozzle exit width on rotating detonation engine

    Science.gov (United States)

    Sun, Jian; Zhou, Jin; Liu, Shijie; Lin, Zhiyong; Cai, Jianhua

    2017-11-01

    A series of numerical simulations of RDE modeling real injection nozzles with different exit widths are performed in this paper. The effects of nozzle exit width on chamber inlet state, plenum flowfield and detonation propagation are analyzed. The results are compared with that using an ideal injection model. Although the ideal injection model is a good approximation method to model RDE inlet, the two-dimensional effects of real nozzles are ignored in the ideal injection model so that some complicated phenomena such as the reflected waves caused by the nozzle walls and the reversed flow into the nozzles can not be modeled accurately. Additionally, the ideal injection model overpredicts the block ratio. In all the cases that stabilize at one-wave mode, the block ratio increases as the nozzle exit width gets smaller. The dual-wave mode case also has a relatively high block ratio. A pressure oscillation in the plenum with the same main frequency with the rotating detonation wave is observed. A parameter σ is applied to describe the non-uniformity in the plenum. σ increases as the nozzle exit width gets larger. Under some condition, the heat release on the interface of fresh premixed gas layer and detonation products can be strong enough to induce a new detonation wave. A spontaneous mode-transition process is observed for the smallest exit width case. Due to the detonation products existing in the premixed gas layer before the detonation wave, the detonation wave will propagate through reactants and products alternately, and therefore its strength will vary with time, especially near the chamber inlet. This tendency gets weaker as the injection nozzle exit width increases.

  13. Stream Width Dynamics in a Small Headwater Catchment

    Science.gov (United States)

    Barefoot, E. A.; Pavelsky, T.; Allen, G. H.; Zimmer, M. A.; McGlynn, B. L.

    2016-12-01

    Changing streamflow conditions cause small, ephemeral and intermittent stream networks to expand and contract, while simultaneously driving widening and narrowing of streams. The resulting dynamic surface area of ephemeral streams impacts critical hydrological and biogeochemical processes, including air-water gas exchange, solute transport, and sediment transport. Despite the importance of these dynamics, to our knowledge there exists no complete study of how stream widths vary throughout an entire catchment in response to changing streamflow conditions. Here we present the first characterization of how variable hydrologic conditions impact the distribution of stream widths in a 48 ha headwater catchment in the Stony Creek Research Watershed, NC, USA. We surveyed stream widths longitudinally every 5 m on 12 occasions over a range of stream discharge from 7 L/s to 128 L/s at the catchment outlet. We hypothesize that the shape and location of the stream width distribution are driven by the action of two interrelated mechanisms, network extension and at-a-station widening, both of which increase with discharge. We observe that during very low flow conditions, network extension more significantly influences distribution location, and during high flow conditions stream widening is the dominant driver. During moderate flows, we observe an approximately 1 cm rightward shift in the distribution peak with every additional 10 L/s of increased discharge, which we attribute to a greater impact of at-a-station widening on distribution location. Aside from this small shift, the qualitative location and shape of the stream width distribution are largely invariant with changing streamflow. We suggest that the basic characteristics of stream width distributions constitute an equilibrium between the two described mechanisms across variable hydrologic conditions.

  14. The Application of Timer 555 for Pulse Generator in the Process Control of the D-Gun Coating

    International Nuclear Information System (INIS)

    Machmud, Farid W.; Diah Intani; Isnaeni; Cece

    2002-01-01

    Many instrumentation of control that using electronic pulse has been found utilized to control manufacturing process in industry. The pulses were produced by oscillator circuit act as input for logic circuit then adjusts pulse properly to the process. In this work, a simple digital control instrumentation was designed and implemented for the D G un coating process. Timer 555 for adjusting oscillator pulse width could control the gas, powder feeder, and detonation frequency. The other logic circuit that was consists of one synchronize counter and some logic gate XOR, OR, AND, and NOT were adjusting pulses to produce pulses for actuator related to the processes queue. The pulses characterization show that high and low pulse width will be the same if the comparison of the two resistors of bandwidth controller almost half for a value of outer capacitor. The implementation shows that the detonation frequency was greater than 1 Hz when the capacitors value is 20μF or less, while the adjustment of pulse width to fuel actuators and O 2 describe the comparison of the gas, and pulse width to powder feeder describe the amount of powder that have been injected to fire chamber of D G un. From the characterizations and the implementation we conclude that some parameters of the D G un coating can be controlled by the bandwidth of the timer. (author)

  15. A compact high-voltage pulse generator based on pulse transformer with closed magnetic core.

    Science.gov (United States)

    Zhang, Yu; Liu, Jinliang; Cheng, Xinbing; Bai, Guoqiang; Zhang, Hongbo; Feng, Jiahuai; Liang, Bo

    2010-03-01

    A compact high-voltage nanosecond pulse generator, based on a pulse transformer with a closed magnetic core, is presented in this paper. The pulse generator consists of a miniaturized pulse transformer, a curled parallel strip pulse forming line (PFL), a spark gap, and a matched load. The innovative design is characterized by the compact structure of the transformer and the curled strip PFL. A new structure of transformer windings was designed to keep good insulation and decrease distributed capacitance between turns of windings. A three-copper-strip structure was adopted to avoid asymmetric coupling of the curled strip PFL. When the 31 microF primary capacitor is charged to 2 kV, the pulse transformer can charge the PFL to 165 kV, and the 3.5 ohm matched load can deliver a high-voltage pulse with a duration of 9 ns, amplitude of 84 kV, and rise time of 5.1 ns. When the load is changed to 50 ohms, the output peak voltage of the generator can be 165 kV, the full width at half maximum is 68 ns, and the rise time is 6.5 ns.

  16. A compact bipolar pulse-forming network-Marx generator based on pulse transformers.

    Science.gov (United States)

    Zhang, Huibo; Yang, Jianhua; Lin, Jiajin; Yang, Xiao

    2013-11-01

    A compact bipolar pulse-forming network (PFN)-Marx generator based on pulse transformers is presented in this paper. The high-voltage generator consisted of two sets of pulse transformers, 6 stages of PFNs with ceramic capacitors, a switch unit, and a matched load. The design is characterized by the bipolar pulse charging scheme and the compact structure of the PFN-Marx. The scheme of bipolar charging by pulse transformers increased the withstand voltage of the ceramic capacitors in the PFNs and decreased the number of the gas gap switches. The compact structure of the PFN-Marx was aimed at reducing the parasitic inductance in the generator. When the charging voltage on the PFNs was 35 kV, the matched resistive load of 48 Ω could deliver a high-voltage pulse with an amplitude of 100 kV. The full width at half maximum of the load pulse was 173 ns, and its rise time was less than 15 ns.

  17. Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron

    International Nuclear Information System (INIS)

    Kurashima, Satoshi; Miyawaki, Nobumasa; Kashiwagi, Hirotsugu; Okumura, Susumu; Taguchi, Mitsumasa; Fukuda, Mitsuhiro

    2015-01-01

    The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method

  18. CO2-Tea pulse clipping using pulsed high voltage preionization for high spatial resolution I.R. Lidar systems

    Directory of Open Access Journals (Sweden)

    Gasmi Taieb

    2018-01-01

    Full Text Available An extra-cavity CO2-TEA laser pulse clipper for high spatial resolution atmospheric monitoring is presented. The clipper uses pulsed high voltageto facilitate the breakdown of the gas within the clipper cell. Complete extinction of the nitrogen tail, that degrades the range resolution of LIDARS, is obtained at pressures from 375 up to 1500 Torr for nitrogen and argon gases whereas an attenuation coefficient of almost 102 is achieved for helium. Excellent energy stability and pulse width repeatability were achieved using high voltage pre-ionized gas technique.

  19. CO2-Tea pulse clipping using pulsed high voltage preionization for high spatial resolution I.R. Lidar systems

    Science.gov (United States)

    Gasmi, Taieb

    2018-04-01

    An extra-cavity CO2-TEA laser pulse clipper for high spatial resolution atmospheric monitoring is presented. The clipper uses pulsed high voltageto facilitate the breakdown of the gas within the clipper cell. Complete extinction of the nitrogen tail, that degrades the range resolution of LIDARS, is obtained at pressures from 375 up to 1500 Torr for nitrogen and argon gases whereas an attenuation coefficient of almost 102 is achieved for helium. Excellent energy stability and pulse width repeatability were achieved using high voltage pre-ionized gas technique.

  20. Thermal Width for Heavy Quarkonium in the Static Limit

    International Nuclear Information System (INIS)

    Shi Chao-Yi; Zhu Jia-Qing; Ma Zhi-Lei; Li Yun-De

    2015-01-01

    The thermal widths for heavy quarkonia are calculated for both Coulomb gauge (CG) and Feynman gauge (FG), and the comparisons between these results with the hard thermal loop (HTL) approximation ones are illustrated. The dissociation temperatures of heavy quarkonia in thermal medium are also discussed for CG, FG and HTL cases. It is shown that the thermal widths, derived from the HTL approximation and used in many research studies, cause some errors in the practical calculations at the temperature range accessible in the present experiment, and the problem of gauge dependence cannot be avoided when the complete self energy is used in the derivation of potential. (paper)

  1. Statistical analysis of s-wave neutron reduced widths

    International Nuclear Information System (INIS)

    Pandita Anita; Agrawal, H.M.

    1992-01-01

    The fluctuations of the s-wave neutron reduced widths for many nuclei have been analyzed with emphasis on recent measurements by a statistical procedure which is based on the method of maximum likelihood. It is shown that the s-wave neutron reduced widths of nuclei follow single channel Porter Thomas distribution (x 2 -distribution with degree of freedom ν = 1) for most of the cases. However there are apparent deviations from ν = 1 and possible explanation and significance of this deviation is given. These considerations are likely to modify the evaluation of neutron cross section. (author)

  2. Domain wall width of lithium niobate poled during growth

    CERN Document Server

    Brooks, R; Hole, D E; Callejo, D; Bermudez, V; Diéguez, E

    2003-01-01

    Good quality crystals of periodically poled lithium niobate can be generated directly during growth. However, the temperature gradients at the zone boundaries define the width of the regions where the polarity is reversed. Hence, the region influenced the domain transition may be a significant fraction of the overall poling period for material poled during growth. Evidence for the scale of this feature is reported both by chemical etching and by the less common method of ion beam luminescence and the 'domain wall' width approximately 1 mu m for these analyses. The influence of the reversal region may differ for alternative techniques but the relevance to device design for second harmonic generation is noted.

  3. Level and width statistics for a decaying chaotic system

    International Nuclear Information System (INIS)

    Mizutori, S.; Zelevinsky, V.G.

    1993-01-01

    The random matrix ensemble of discretized effective non-hermitian hamiltonians is used for studying local correlations and fluctuations of energies and widths in a quantum system where intrinsic levels are coupled to the continuum via a common decay channel. With the use of analytical estimates and numerical simulations, generic properties of statistical observables are obtained for the regimes of weak and strong continuum coupling as well as for the transitional region. Typical signals of the transition (width collectivization, disappearance of level repulsion at small spacings and violation of uniformity along the energy axis) are discussed quantitatively. (orig.)

  4. The effect of increased intra-abdominal pressure on orbital subarachnoid space width and intraocular pressure.

    Science.gov (United States)

    Liu, Su-Meng; Wang, Ning-Li; Zuo, Zhen-Tao; Chen, Wei-Wei; Yang, Di-Ya; Li, Zhen; Cao, Yi-Wen

    2018-02-01

    In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can relieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 ± 0.1 mm (range: 0.77-1.05 mm), 0.77 ± 0.11 mm (range: 0.60-0.94 mm), 0.70 ± 0.08 mm (range: 0.62-0.80 mm), and 0.68 ± 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the

  5. Pump-beam-instability limits to Raman-gain-doublet ''fast-light'' pulse propagation

    International Nuclear Information System (INIS)

    Stenner, Michael D.; Gauthier, Daniel J.

    2003-01-01

    We investigate the behavior of a system for generating ''fast-light'' pulses in which a bichromatic Raman pumping beam is used to generate optical gain at two frequencies and a region of anomalous dispersion between them. It is expected that increasing the gain will increase the pulse advancement. However, as the gain increases, the pumping field becomes increasingly distorted, effectively limiting the pulse advancement. We observe as much as 12% of the input pump power converted to orthogonal polarization, broadening of the initially bichromatic pump field (25 MHz initial frequency separation) to more than 2.5 GHz, and a temporal collapse of the pump beam into an erratic train of sub-500-ps pulses. The instability is attributed to the combined effects of the cross modulation instability and stimulated Raman scattering. Extreme distortion of an injected pulse that should (absent the instability) experience an advancement of 21% of its width is observed. We conclude that the fast-light pulse advancement is limited to just a few percent of the pulse width using this pulse advancement technique. The limitation imposed by the instability is important because careful study of the information velocity in fast-light pulses requires that pulse advancement be large enough to distinguish the velocities of different pulse features. Possible methods for achieving pulse advancement by avoiding the distortion caused by the instability are discussed

  6. Chirped pulse digital holography for measuring the sequence of ultrafast optical wavefronts

    Science.gov (United States)

    Karasawa, Naoki

    2018-04-01

    Optical setups for measuring the sequence of ultrafast optical wavefronts using a chirped pulse as a reference wave in digital holography are proposed and analyzed. In this method, multiple ultrafast object pulses are used to probe the temporal evolution of ultrafast phenomena and they are interfered with a chirped reference wave to record a digital hologram. Wavefronts at different times can be reconstructed separately from the recorded hologram when the reference pulse can be treated as a quasi-monochromatic wave during the pulse width of each object pulse. The feasibility of this method is demonstrated by numerical simulation.

  7. A rotationally symmetric electron beam chopper for picosecond pulses

    International Nuclear Information System (INIS)

    Oldfield, L.C.

    1976-01-01

    The chopper was designed for dynamic electron optical experiments where it is necessary to provide pulses of high quality with respect to both width and energy spread. The chopping action relies on the optical properties of a microwave cavity; these are exploited such that the time dependent space focusing causes a small circular aperture on the axis of rotational symmetry to transmit strongly for a single band of phase angles in each cycle of the excitation. Unless the pulses are to be used near the aperture plane, an 'energy correcting' cavity that operates in phase synchronism with the chopper is added to the system. The theoretical treatment is oriented towards computer display, and is novel in that it follows the progress of individual electron packets throughout the system. In contrast to conventional chopping and bunching theory, it is possible to analyse with ease the pulsing properties of a multicavity device. For a typical two-cavity design the pulse quality may range from 10 0 width and negligible energy spread, to 0.25% energy spread and negligible pulse width, depending on the second cavity excitation; in either situation 7.5% of the original steady beam is transmitted. (author)

  8. Selection of heat transfer model for describing short-pulse laser heating silica-based sensor

    International Nuclear Information System (INIS)

    Hao Xiangnan; Nie Jinsong; Li Hua; Bian Jintian

    2012-01-01

    The fundamental equations of Fourier heat transfer model and non-Fourier heat transfer model were numerically solved, with the finite difference method. The relative changes between temperature curves of the two heat transfer models were analyzed under laser irradiation with different pulse widths of 10 ns, 1 ns, 100 ps, 10 ps. The impact of different thermal relaxation time on non-Fourier model results was discussed. For pulses of pulse width less than or equal to 100 ps irradiating silicon material, the surface temperature increases slowly and carrier effect happens, which the non-Fourier model can reflect properly. As for general material, when the pulse width is less than or equal to the thermal relaxation time of material, carrier effect occurs. In this case, the non-Fourier model should be used. (authors)

  9. Usefulness of meniscal width to transverse diameter ratio on coronal MRI in the diagnosis of incomplete discoid lateral meniscus

    International Nuclear Information System (INIS)

    Park, H.J.; Lee, S.Y.; Park, N.-H.; Chung, E.C.; Park, J.Y.; Kim, M.S.; Lee, E.J.

    2014-01-01

    Aim: To evaluate the clinical utility of the meniscal width to transverse diameter ratio (L/M ratio) of the lateral meniscus in the diagnosis of incomplete discoid lateral meniscus (IDLM) as compared with the arthroscopic diagnosis, meniscal width to tibial diameter ratio (L/T ratio) and conventional lateral meniscus width criteria. Materials and methods: This retrospective study sample included 41 patients with IDLM who underwent knee magnetic resonance imaging (MRI) and arthroscopy, as well as 50 controls with normal lateral menisci. MRI examinations were interpreted independently by two radiologists, both of whom were blinded to clinical information and radiological reports. Assessment of meniscal width (L), maximal transverse diameter of the lateral meniscus (M), and transverse diameter of the tibia (T) was carried out on central coronal sections that were observed to pass through the medial collateral ligament. L/M and L/T ratios were calculated. These results were correlated with arthroscopic findings and analysed statistically using categorical regression analysis and non-parametric correlation analysis. Using arthroscopic findings as the standard of reference, sensitivity and specificity were calculated for: (1) 12, 13, 14, and 15 mm meniscal width thresholds; (2) 40%, 50%, 60%, and 70% L/M ratio thresholds; and (3) 15%, 18%, 20%, and 25% L/T ratio thresholds. Results: The mean L/M ratio of the IDLM was approximately 67% and was statistically significantly higher than the control (44%). The best diagnostic discrimination was achieved using a threshold of 50%. The mean L/T ratio of the IDLM was approximately 23% and was statistically significant. The best diagnostic discrimination was achieved using a threshold of 18%. The threshold of 13 mm of meniscal width also showed high sensitivity and high specificity. Conclusion: The use of the L/M ratio or L/T ratio in combination with meniscal width criteria may be a useful method for evaluating IDLM

  10. A 16.3 pJ/pulse low-complexity and energy-efficient transmitter with adjustable pulse parameters

    International Nuclear Information System (INIS)

    Jiang Jun; Zhao Yi; Shao Ke; Chen Hu; Xia Lingli; Hong Zhiliang

    2011-01-01

    This paper presents a novel, fully integrated transmitter for 3-5 GHz pulsed UWB. The BPSK modulation transmitter has been implemented in SMIC CMOS 0.13 μm technology with a 1.2-V supply voltage and a die size of 0.8 x 0.95 mm 2 . This transmitter is based on the impulse response filter method, which uses a tunable R paralleled with a LC frequency selection network to realize continuously adjustable pulse parameters, including bandwidth, width and amplitude. Due to the extremely low duty of the pulsed UWB, a proposed output buffer is employed to save power consumption significantly. Finally, measurement results show that the transmitter consumes only 16.3 pJ/pulse to achieve a pulse repetition rate of 100 Mb/s. Generated pulses strictly comply with the FCC spectral mask. The continuously variable pulse width is from 900 to 1.5 ns and the amplitude with the minimum 178 mVpp and the maximum 432 mVpp can be achieved. (semiconductor integrated circuits)

  11. Pulsed water jet generated by pulse multiplication

    Czech Academy of Sciences Publication Activity Database

    Dvorský, R.; Sitek, Libor; Sochor, T.

    2016-01-01

    Roč. 23, č. 4 (2016), s. 959-967 ISSN 1330-3651 R&D Projects: GA MŠk(CZ) LO1406; GA MŠk ED2.1.00/03.0082 Institutional support: RVO:68145535 Keywords : high- pressure pulses * pulse intensifier * pulsed water jet * water hammer effect Subject RIV: JQ - Machines ; Tools Impact factor: 0.723, year: 2016 http://hrcak.srce.hr/163752?lang=en

  12. A long pulse modulator for reduced size and cost

    International Nuclear Information System (INIS)

    Pfeffer, H.; Bartelson, L.; Bourkland, K.; Jensen, C.; Kerns, Q.; Prieto, P.; Saewert, G.; Wolff, D.

    1994-07-01

    A novel modulator has been designed, built and tested for the TESLA test facility. This e + e - accelerator concept uses superconducting RF cavities and requires 2ms of RF power at 10 pps. As the final accelerator will require several hundred modulators, a cost effective, space saving and high efficiency design is desired. This modulator used a modest size switched capacitor bank that droops approximately 20% during the pulse. This large droop is compensated for by the use of a resonant LC circuit. The capacitor bank is connected to the high side of a pulse transformer primary using a series GTO switch. The resonant circuit is connected to the low side of the pulse transformer primary. The output pulse is flat to within 1% for 1.9 ms during a 2.3 ms base pulse width. Measured efficiency, from breaker to klystron and including energy lost in the rise time, is approximately 85%

  13. Study of general digital DC/pulse neutron generator

    International Nuclear Information System (INIS)

    Li Gang; Liu Zheng; Li Wensheng; Liu Hanlin; Liu Linmao

    2014-01-01

    Preliminary experimental results of digital DC/pulse neutron generator based on a ceramic drive-in target neutron tube for explosives detection are presented. The generator is a portable and on-off neutron source, and it can be controlled by remote PC. The generator can produce DC neutrons, pulse neutrons and multiple pulse neutrons. The maximum neutron yield is about 2 × 10"8 n/s, the minimum pulse width is 10 μs and the maximum pulse frequency is 10 kHz. Neutron yield and time-spectrum is measured in China Academy of Engineering Physics. The generator is suitable for explosive detection with PFTNA technology, and it can be used in other areas such as reactor measurements and on-line industrial test systems. (authors)

  14. Laser modification of silica, simulating pulse shape and length

    International Nuclear Information System (INIS)

    Corrales, L. Rene; Moore, Emily

    2009-01-01

    Computer simulations of instantaneous thermal heating due to a laser pulse is modeled as a pulse occurring over 1 or 100 fs, during which time the atoms within a cylinder are given excess kinetic energy to mimic the effect of adding energy locally to a system by a laser. The response of the material under conditions in which a similar amount of energy is dumped within 1 fs versus over a 100 fs pulse with two distinct shapes, square and Gaussian-like, is explored. Key physics disclosed is that with a pulse width of 100 fs, as the energy is being added it begins to dissipate away from region where it is added. With a 1 fs (instantaneous) pulse there is greater initial ballistic behavior than when it is dumped over a 100 fs period. In the latter, there are localized hot spots displaying ballistic behavior.

  15. Writer identification using directional ink-trace width measurements

    NARCIS (Netherlands)

    Brink, A. A.; Smit, J.; Bulacu, M. L.; Schomaker, L. R. B.

    As suggested by modern paleography, the width of ink traces is a powerful source of information for off-line writer identification, particularly if combined with its direction. Such measurements can be computed using simple, fast and accurate methods based on pixel contours, the combination of which

  16. Turbulent transport regimes and the SOL heat flux width

    Science.gov (United States)

    Myra, J. R.; D'Ippolito, D. A.; Russell, D. A.

    2014-10-01

    Understanding the responsible mechanisms and resulting scaling of the scrape-off layer (SOL) heat flux width is important for predicting viable operating regimes in future tokamaks, and for seeking possible mitigation schemes. Simulation and theory results using reduced edge/SOL turbulence models have produced SOL widths and scalings in reasonable accord with experiments in many cases. In this work, we attempt to qualitatively and conceptually understand various regimes of edge/SOL turbulence and the role of turbulent transport in establishing the SOL heat flux width. Relevant considerations include the type and spectral characteristics of underlying instabilities, the location of the gradient drive relative to the SOL, the nonlinear saturation mechanism, and the parallel heat transport regime. Recent SOLT turbulence code results are employed to understand the roles of these considerations and to develop analytical scalings. We find a heat flux width scaling with major radius R that is generally positive, consistent with older results reviewed in. The possible relationship of turbulence mechanisms to the heuristic drift mechanism is considered, together with implications for future experiments. Work supported by US DOE grant DE-FG02-97ER54392.

  17. The effect of buffer zone width on biodiversity

    DEFF Research Database (Denmark)

    Navntoft, Søren; Sigsgaard, Lene; Kristensen, Kristian Morten

    2012-01-01

    Field margin management for conservation purposes is a way to protect both functional biodiversity and biodiversity per se without considerable economical loss as field margins are less productive. However, the effect of width of the buffer zone on achievable biodiversity gains has received littl...

  18. Joint space width in dysplasia of the hip

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig; Søballe, K

    2005-01-01

    . Neither subjects with dysplasia nor controls had radiological signs of ongoing degenerative disease at admission. The primary radiological discriminator of degeneration of the hip was a change in the minimum joint space width over time. There were no significant differences between these with dysplasia...

  19. Widths of the atomic K-N7 levels

    International Nuclear Information System (INIS)

    Campbell, J.L.; Papp, Tibor

    2001-01-01

    Atomic level widths obtained from experimental measurements are collected in Table I, along with the corresponding theoretical widths derived from the Evaluated Atomic Data Library (EADL) of Lawrence Livermore National Laboratory; these EADL values are based upon the Dirac-Hartree-Slater version of the independent-particle model. In a minority of cases, many-body theory predictions are also provided. A brief discussion of the manner in which the experimental widths were deduced from spectroscopic data is included. The bulk of the data are for elements in the solid state, but a few data for gases and simple compounds are included. For the K, L2, L3, and M5 levels, where Coster-Kronig contributions do not contribute or contribute only to a small extent to the overall widths, the EADL predictions appear satisfactory for elements in the solid state. For other levels, where Coster-Kronig and super-Coster-Kronig transitions have large probabilities within the independent-particle model, this model is not satisfactory. Table II provides a complete set of recommended elemental values based upon consideration of the available experimental data

  20. Partial Widths of Nonmesonic Weak Decays of Lambda-Hypernuclei

    CERN Document Server

    Kuzmin, V A

    2002-01-01

    It is shown that the phenomenological matrix elements completely describing \\Lambda N \\to NN weak interaction in the 1p-shell nuclei can be obtained from the partial widths of nonmesonic decays of ^{10}_{\\Lambda}Be and ^{10}_{\\Lambda}B hypernuclei. It is shown that the uncertainties related to the description of nuclear structure are not essential for this task.

  1. Downstream flow top width prediction in a river system | Choudhury ...

    African Journals Online (AJOL)

    ANFIS, ARIMA and Hybrid Multiple Inflows Muskingum models (HMIM) were applied to simulate and forecast downstream discharge and flow top widths in a river system. The ANFIS model works on a set of linguistic rules while the ARIMA model uses a set of past values to predict the next value in a time series. The HMIM ...

  2. Measurement of joint space width and erosion size

    NARCIS (Netherlands)

    Sharp, JI; van der Heijde, D; Angwin, J; Duryea, J; Moens, HJB; Jacobs, JWG; Maillefert, JF; Strand, CV

    2005-01-01

    Measurement of radiographic abnormalities in metric units has been reported by several investigators during the last 15 years. Measurement of joint space in large joints has been employed in a few trials to evaluate therapy in osteoarthritis. Measurement of joint space width in small joints has been

  3. Soft error rate analysis methodology of multi-Pulse-single-event transients

    International Nuclear Information System (INIS)

    Zhou Bin; Huo Mingxue; Xiao Liyi

    2012-01-01

    As transistor feature size scales down, soft errors in combinational logic because of high-energy particle radiation is gaining more and more concerns. In this paper, a combinational logic soft error analysis methodology considering multi-pulse-single-event transients (MPSETs) and re-convergence with multi transient pulses is proposed. In the proposed approach, the voltage pulse produced at the standard cell output is approximated by a triangle waveform, and characterized by three parameters: pulse width, the transition time of the first edge, and the transition time of the second edge. As for the pulse with the amplitude being smaller than the supply voltage, the edge extension technique is proposed. Moreover, an efficient electrical masking model comprehensively considering transition time, delay, width and amplitude is proposed, and an approach using the transition times of two edges and pulse width to compute the amplitude of pulse is proposed. Finally, our proposed firstly-independently-propagating-secondly-mutually-interacting (FIP-SMI) is used to deal with more practical re-convergence gate with multi transient pulses. As for MPSETs, a random generation model of MPSETs is exploratively proposed. Compared to the estimates obtained using circuit level simulations by HSpice, our proposed soft error rate analysis algorithm has 10% errors in SER estimation with speed up of 300 when the single-pulse-single-event transient (SPSET) is considered. We have also demonstrated the runtime and SER decrease with the increment of P0 using designs from the ISCAS-85 benchmarks. (authors)

  4. Wire Electrical Discharge Machining of a Hybrid Composite: Evaluation of Kerf Width and Surface Roughness

    Directory of Open Access Journals (Sweden)

    Abdil KUŞ

    2016-06-01

    Full Text Available In this study, the machinability characteristics of Al/B4C-Gr hybrid composite were investigated using wire electrical discharge machining (WEDM. In the experiments, the machining parameters of wire speed, pulse-on time and pulse-off time were varied in order to explaiın their effects on machining performance, including the width of slit (kerf and surface roughness values (Rz and Rt. According to the Taguchi quality design concept, a L18 (21×32 orthogonal array was used to determine the S/N ratio, and analysis of variance (ANOVA and the F-test were used to indicate the significant machining parameters affecting the machining performance. From the ANOVA and F-test results, the significant factors were determined for each of the machining performance criteria of kerf, Rz and Rt. The variations of kerf, Rz and Rt with the machining parameters were statistically modeled via the regression analysis method. The optimum levels of the control factors for kerf, Rz and Rt were specified as A1B1C1, A1B1C2 and A1B1C2, respectively. The correlation coefficients of the predictive equations developed for kerf, Rz and Rt were calculated as 0.98, 0.828 and 0.855, respectively.

  5. Modeling of dislocation channel width evolution in irradiated metals

    Science.gov (United States)

    Doyle, Peter J.; Benensky, Kelsa M.; Zinkle, Steven J.

    2018-02-01

    Defect-free dislocation channel formation has been reported to promote plastic instability during tensile testing via localized plastic flow, leading to a distinct loss of ductility and strain hardening in many low-temperature irradiated materials. In order to study the underlying mechanisms governing dislocation channel width and formation, the channel formation process is modeled via a simple stochastic dislocation-jog process dependent upon grain size, defect cluster density, and defect size. Dislocations traverse a field of defect clusters and jog stochastically upon defect interaction, forming channels of low defect-density. Based upon prior molecular dynamics (MD) simulations and in-situ experimental transmission electron microscopy (TEM) observations, each dislocation encounter with a dislocation loop or stacking fault tetrahedron (SFT) is assumed to cause complete absorption of the defect cluster, prompting the dislocation to jog up or down by a distance equal to half the defect cluster diameter. Channels are predicted to form rapidly and are comparable to reported TEM measurements for many materials. Predicted channel widths are found to be most strongly dependent on mean defect size and correlated well with a power law dependence on defect diameter and density, and distance from the dislocation source. Due to the dependence of modeled channel width on defect diameter and density, maximum channel width is predicted to slowly increase as accumulated dose increases. The relatively weak predicted dependence of channel formation width with distance, in accordance with a diffusion analogy, implies that after only a few microns from the source, most channels observed via TEM analyses may not appear to vary with distance because of limitations in the field-of-view to a few microns. Further, examinations of the effect of the so-called "source-broadening" mechanism of channel formation showed that its effect is simply to add a minimum thickness to the channel

  6. Influence of MLC leaf width on biologically adapted IMRT plans

    Energy Technology Data Exchange (ETDEWEB)

    Roedal, Jan; Soevik, Aaste; Malinen, Eirik (Dept. of Medical Physics, The Norwegian Radium Hospital, Oslo Univ. Hospital, Oslo (Norway)), E-mail: jan.rodal@radiumhospitalet.no

    2010-10-15

    Introduction. High resolution beam delivery may be required for optimal biology-guided adaptive therapy. In this work, we have studied the influence of multi leaf collimator (MLC) leaf widths on the treatment outcome following adapted IMRT of a hypoxic tumour. Material and methods. Dynamic contrast enhanced MR images of a dog with a spontaneous tumour in the nasal region were used to create a tentative hypoxia map following a previously published procedure. The hypoxia map was used as a basis for generating compartmental gross tumour volumes, which were utilised as planning structures in biologically adapted IMRT. Three different MLCs were employed in inverse treatment planning, with leaf widths of 2.5 mm, 5 mm and 10 mm. The number of treatment beams and the degree of step-and-shoot beam modulation were varied. By optimising the tumour control probability (TCP) function, optimal compartmental doses were derived and used as target doses in the inverse planning. Resulting IMRT dose distributions and dose volume histograms (DVHs) were exported and analysed, giving estimates of TCP and compartmental equivalent uniform doses (EUDs). The impact of patient setup accuracy was simulated. Results. The MLC with the smallest leaf width (2.5 mm) consistently gave the highest TCPs and compartmental EUDs, assuming no setup error. The difference between this MLC and the 5 mm MLC was rather small, while the MLC with 10 mm leaf width gave considerably lower TCPs. When including random and systematic setup errors, errors larger than 5 mm gave only small differences between the MLC types. For setup errors larger than 7 mm no differences were found between non-uniform and uniform dose distributions. Conclusions. Biologically adapted radiotherapy may require MLCs with leaf widths smaller than 10 mm. However, for a high probability of cure it is crucial that accurate patient setup is ensured.

  7. Repeated pulsed x-ray emission equipment

    International Nuclear Information System (INIS)

    Terauchi, Hikaru; Iida, Satoshi

    1982-01-01

    X-ray diffraction technique has been applied to determine the spatial positions of atoms which compose a material, and it is needless to say that the technique is a fundamental means regardless of the fields of research. However, the application of X-ray diffraction to the research on physical properties has been so far limited to know the spatial positions of atoms or molecules under thermal equilibrium condition. The addition of time element to the conventional technique, that is, the analysis of material structure including the time-varying processes under non-equilibrium conditions, is considered to approach the elucidation of the essence of materials. The authors call this dynamic structural analysis. The authors have planned to analyze X-ray diffraction intensity which has the resolution of about 10 -8 s in the real time which is conjugate with energy. However, present pulsed X-ray sources are not suitable for diffraction experiment because the pulse width is too long or X-ray wavelength is too short. Accordingly, the authors have made for trial a pulsed X-ray source for diffraction experiment. Its specifications are: diode voltage (X-ray tube voltage) from 200 to 300 kV, diode current from 2 to 5 kA, pulse width of about 30ns, maximum repetition frequency 10 pps, and X-ray focus size of 2 mm diameter. One of the features of this source is the repeated generation of pulsed X-ray. This is the first trial in the world, and is indispensable to the dynamic structural analysis described above. The quality of the emitted X-ray is also written. (Wakatsuki, Y.)

  8. Investigation of the effect of finite pulse errors on the BABA pulse sequence using the Floquet-Magnus expansion approach

    Science.gov (United States)

    Mananga, Eugene S.; Reid, Alicia E.

    2013-01-01

    This paper presents a study of finite pulse widths for the BABA pulse sequence using the Floquet-Magnus expansion (FME) approach. In the FME scheme, the first order ? is identical to its counterparts in average Hamiltonian theory (AHT) and Floquet theory (FT). However, the timing part in the FME approach is introduced via the ? function not present in other schemes. This function provides an easy way for evaluating the spin evolution during the time in between' through the Magnus expansion of the operator connected to the timing part of the evolution. The evaluation of ? is particularly useful for the analysis of the non-stroboscopic evolution. Here, the importance of the boundary conditions, which provide a natural choice of ? , is ignored. This work uses the ? function to compare the efficiency of the BABA pulse sequence with ? and the BABA pulse sequence with finite pulses. Calculations of ? and ? are presented.

  9. Picosecond chirped pulse compression in single-mode fibers

    International Nuclear Information System (INIS)

    Wenhua Cao; Youwei Zhang

    1995-01-01

    In this paper, the nonlinear propagation of picosecond chirped pulses in single mode fibers has been investigated both analytically and numerically. Results show that downchirped pulses can be compressed owing to normal group-velocity dispersion. The compression ratio depends both on the initial peak power and on the initial frequency chirp of the input pulse. While the compression ratio depends both on the initial peak power and on the initial frequency chirp of the input pulse. While the compression ratio increases with the negative frequency chirp, it decreases with the initial peak power of the input pulse. This means that the self-phase modulation induced nonlinear frequency chirp which is linear and positive (up-chirp) over a large central region of the pulse and tends to cancel the initial negative chirp of the pulse. It is also shown that, as the negative chirped pulse compresses temporally, it synchronously experiences a spectral narrowing

  10. A Radiation Dosimetry Method Using Pulsed Optically Stimulated Luminescence

    International Nuclear Information System (INIS)

    Akselrod, M.S.; McKeever, S.W.S.

    1999-01-01

    A method for the determination of absorbed radiation dose is described based on pulsed optically stimulated luminescence (POSL). The method relies upon the stimulation of an irradiated sample with a train of light pulses from a suitable light source (e.g. a laser) using a wavelength which is within the range of wavelengths corresponding to the radiation-induced optical absorption in the irradiated sample. The subsequent emitted light, due to the detrapping of trapped charges and their subsequent recombination with charge of the opposite sign, is synchronously detected in the period between each stimulation pulse. The total luminescence is summed over the desired number of stimulation pulses and this forms the measured POSL signal. By monitoring the emitted light only in the period between stimulation pulses one can reduce the optical filtering required to discriminate between the stimulation light and the emission light; in this way a high measurement efficiency, and, therefore, a high radiation sensitivity (luminescence intensity per unit absorbed dose) is achieved. Key parameters in the method are the intrinsic luminescence lifetime for the material being used as the luminescent detector, the width of the optical stimulation pulse, and the period between pulses. For optimum operation the measurement parameters should be such that both the pulse width and the time between pulses are much less than the luminescence lifetime. By appropriate choice of the power of the optical stimulation, the frequency of the stimulation pulses, and the total stimulation period, one can also re-measure the absorbed dose several times. In this way, a re-read capability is available with the procedure. The method is illustrated using light from a 2nd-harmonic Nd:YAG laser, with irradiated, anion-deficient aluminium oxide as the luminescent detector material. (author)

  11. Peak Source Power Associated with Positive Narrow Bipolar Lightning Pulses

    Science.gov (United States)

    Bandara, S. A.; Marshall, T. C.; Karunarathne, S.; Karunarathne, N. D.; Siedlecki, R. D., II; Stolzenburg, M.

    2017-12-01

    During the summer of 2016, we deployed a lightning sensor array in and around Oxford Mississippi, USA. The array system comprised seven lightning sensing stations in a network approximately covering an area of 30 km × 30 km. Each station is equipped with four sensors: Fast antenna (10 ms decay time), Slow antenna (1.0 s decay time)), field derivative sensor (dE/dt) and Log-RF antenna (bandwidth 187-192 MHz). We have observed 319 Positive NBPs and herein we report on comparisons of the NBP properties measured from the Fast antenna data with the Log-RF antenna data. These properties include 10-90% rise time, full width at half maximum, zero cross time, and range-normalized amplitude at 100 km. NBPs were categorized according to the fine structure of the electric field wave shapes into Types A-D, as in Karunarathne et al. [2015]. The source powers of NBPs in each category were determined using single station Log-RF data. Furthermore, we also categorized the NBPs in three other groups: initial event of an IC flash, isolated, and not-isolated (according to their spatiotemporal relationship with other lightning activity). We compared the source powers within each category. Karunarathne, S., T. C. Marshall, M. Stolzenburg, and N. Karunarathna (2015), Observations of positive narrow bipolar pulses, J. Geophys. Res. Atmos., 120, doi:10.1002/2015JD023150.

  12. Laser pulse stacking method

    Science.gov (United States)

    Moses, E.I.

    1992-12-01

    A laser pulse stacking method is disclosed. A problem with the prior art has been the generation of a series of laser beam pulses where the outer and inner regions of the beams are generated so as to form radially non-synchronous pulses. Such pulses thus have a non-uniform cross-sectional area with respect to the outer and inner edges of the pulses. The present invention provides a solution by combining the temporally non-uniform pulses in a stacking effect to thus provide a more uniform temporal synchronism over the beam diameter. 2 figs.

  13. High-voltage pulse generator synchronous with LINAC

    International Nuclear Information System (INIS)

    Muto, M.; Hiratsuka, Yoshio; Niimura, Nobuo

    1974-01-01

    High-voltage pulse generator (H.V. Flip-Flop) No.2, an improved type of No.1, is described, which is used in the structural analysis of transient phenomena in materials through the neutron TOF with a Linac. The method of producing positive and negative high-voltage pulses synchronous with the Linac is identical with that in No.1. However, No.2 has outstanding features as follows: (1) The rise time of output pulses is reduced to 0.3 msec, due to the improvement of switching circuit and the winding of a step-up transformer; (2) The widths of positive and negative pulses are variable up to maximum 8 and 16 frames, respectively (One frame = 10 msec); (3) The distribution of TOF signals from a BF 3 counter to a time analyzer is possible even in the negative voltage duration. The panel is provided with the switches for choosing pulse width and the frame for analysis, as well as the dials for setting positive/negative pulse voltage values and the respective indicating meters. (Mori, K)

  14. Spectral Flattening at Low Frequencies in Crab Giant Pulses

    Science.gov (United States)

    Meyers, B. W.; Tremblay, S. E.; Bhat, N. D. R.; Shannon, R. M.; Kirsten, F.; Sokolowski, M.; Tingay, S. J.; Oronsaye, S. I.; Ord, S. M.

    2017-12-01

    We report on simultaneous wideband observations of Crab giant pulses with the Parkes radio telescope and the Murchison Widefield Array (MWA). The observations were conducted simultaneously at 732 and 3100 MHz with Parkes and at 120.96, 165.76, and 210.56 MHz with the MWA. Flux density calibration of the MWA data was accomplished using a novel technique based on tied-array beam simulations. We detected between 90 and 648 giant pulses in the 120.96-210.56 MHz MWA subbands above a 5.5σ threshold, while in the Parkes subbands we detected 6344 and 231 giant pulses above a threshold of 6σ at 732 and 3100 MHz, respectively. We show, for the first time over a wide frequency range, that the average spectrum of Crab giant pulses exhibits a significant flattening at low frequencies. The spectral index, α, for giant pulses evolves from a steep, narrow distribution with a mean α =-2.6 and width {σ }α =0.5 between 732 and 3100 MHz to a wide, flat distribution of spectral indices with a mean α =-0.7 and width {σ }α =1.4 between 120.96 and 165.76 MHz. We also comment on the plausibility of giant pulse models for fast radio bursts based on this spectral information.

  15. Normal mode analysis for linear resistive magnetohydrodynamics

    International Nuclear Information System (INIS)

    Kerner, W.; Lerbinger, K.; Gruber, R.; Tsunematsu, T.

    1984-10-01

    The compressible, resistive MHD equations are linearized around an equilibrium with cylindrical symmetry and solved numerically as a complex eigenvalue problem. This normal mode code allows to solve for very small resistivity eta proportional 10 -10 . The scaling of growthrates and layer width agrees very well with analytical theory. Especially, both the influence of current and pressure on the instabilities is studied in detail; the effect of resistivity on the ideally unstable internal kink is analyzed. (orig.)

  16. The thoracic paraspinal shadow: normal appearances.

    Science.gov (United States)

    Lien, H H; Kolbenstvedt, A

    1982-01-01

    The width of the right and left thoracic paraspinal shadows were measured at all levels in 200 presumably normal individuals. The paraspinal shadow could be identified in nearly all cases on the left side and in approximately one-third on the right. The range of variation was greater on the left side than one the right. The left paraspinal shadow was wider at the upper levels and in individuals above 40 years of age.

  17. The SOL width and the MHD interchange instability in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Kerner, W [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Pogutse, O [Kurchatov institute, Moscow (Russian Federation)

    1994-07-01

    Instabilities in the SOL plasma can strongly influence the SOL plasma behaviour and in particular the SOL width. The SOL stability analysis shows that there exists a critical ratio of the thermal energy and the magnetic energy. If the SOL beta is greater than this critical value, the magnetic field cannot prevent the plasma displacement and a strong MHD instability in the SOL occurs. In the opposite case only slower resistive instabilities can develop. A theoretical investigation of the SOL plasma stability is presented for JET single-null and double-null divertor configurations. The dependence of the stability threshold on the SOL beta and on the sheath resistance is established. Applying a simple mixing length argument gives the scaling of the SOL width. 5 refs., 2 figs.

  18. Simple discretization method for autoionization widths. III. Molecules

    International Nuclear Information System (INIS)

    Macas, A.; Martn, F.; Riera, A.; Yanez, M.

    1987-01-01

    We apply a new method to calculate widths of two-electron Feshbach resonances, which was described in detail and applied to atomic systems in preceding articles (this issue), to molecular and quasimolecular autoionizing states. For simplicity in the programming effort, we restrict our calculations to the small-R region where one-centered expansions are sufficiently accurate to describe the wave functions. As test cases, positions and widths for the H 2 , He 2 /sup 2+/, HeH + , and LiHe/sup 3+/ resonances of lowest energy are computed for R<0.6 a.u. The advantage of using block-diagonalization techniques to define diabatic resonant states instead of generalizing the Feshbach formalism is pointed out

  19. Joint space width in dysplasia of the hip

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig; Søballe, K

    2005-01-01

    In a longitudinal case-control study, we followed 81 subjects with dysplasia of the hip and 136 control subjects without dysplasia for ten years assessing radiological evidence of degeneration of the hip at admission and follow-up. There were no cases of subluxation in the group with dysplasia....... Neither subjects with dysplasia nor controls had radiological signs of ongoing degenerative disease at admission. The primary radiological discriminator of degeneration of the hip was a change in the minimum joint space width over time. There were no significant differences between these with dysplasia...... and controls in regard to age, body mass index or occupational exposure to daily repeated lifting at admission.We found no significant differences in the reduction of the joint space width at follow-up between subjects with dysplasia and the control subjects nor in self-reported pain in the hip...

  20. Histogram bin width selection for time-dependent Poisson processes

    International Nuclear Information System (INIS)

    Koyama, Shinsuke; Shinomoto, Shigeru

    2004-01-01

    In constructing a time histogram of the event sequences derived from a nonstationary point process, we wish to determine the bin width such that the mean squared error of the histogram from the underlying rate of occurrence is minimized. We find that the optimal bin widths obtained for a doubly stochastic Poisson process and a sinusoidally regulated Poisson process exhibit different scaling relations with respect to the number of sequences, time scale and amplitude of rate modulation, but both diverge under similar parametric conditions. This implies that under these conditions, no determination of the time-dependent rate can be made. We also apply the kernel method to these point processes, and find that the optimal kernels do not exhibit any critical phenomena, unlike the time histogram method

  1. Histogram bin width selection for time-dependent Poisson processes

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Shinsuke; Shinomoto, Shigeru [Department of Physics, Graduate School of Science, Kyoto University, Sakyo-ku, Kyoto 606-8502 (Japan)

    2004-07-23

    In constructing a time histogram of the event sequences derived from a nonstationary point process, we wish to determine the bin width such that the mean squared error of the histogram from the underlying rate of occurrence is minimized. We find that the optimal bin widths obtained for a doubly stochastic Poisson process and a sinusoidally regulated Poisson process exhibit different scaling relations with respect to the number of sequences, time scale and amplitude of rate modulation, but both diverge under similar parametric conditions. This implies that under these conditions, no determination of the time-dependent rate can be made. We also apply the kernel method to these point processes, and find that the optimal kernels do not exhibit any critical phenomena, unlike the time histogram method.

  2. Statistical analysis of P-wave neutron reduced widths

    International Nuclear Information System (INIS)

    Joshi, G.C.; Agrawal, H.M.

    2000-01-01

    The fluctuations of the p-wave neutron reduced widths for fifty one nuclei have been analyzed with emphasis on recent measurements by a statistical procedure which is based on the method of maximum likelihood. It is shown that the p-wave neutron reduced widths of even-even nuclei fallow single channel Porter Thomas distribution (χ 2 -distribution with degree of freedom ν=1) for most of the cases where there are no intermediate structure. It is emphasized that the distribution in nuclei other than even-even may differ from a χ 2 -distribution with one degree of freedom. Possible explanation and significance of this deviation from ν=1 is given. (author)

  3. Explicit and implicit processes in behavioural adaptation to road width.

    Science.gov (United States)

    Lewis-Evans, Ben; Charlton, Samuel G

    2006-05-01

    The finding that drivers may react to safety interventions in a way that is contrary to what was intended is the phenomenon of behavioural adaptation. This phenomenon has been demonstrated across various safety interventions and has serious implications for road safety programs the world over. The present research used a driving simulator to assess behavioural adaptation in drivers' speed and lateral displacement in response to manipulations of road width. Of interest was whether behavioural adaptation would occur and whether we could determine whether it was the result of explicit, conscious decisions or implicit perceptual processes. The results supported an implicit, zero perceived risk model of behavioural adaptation with reduced speeds on a narrowed road accompanied by increased ratings of risk and a marked inability of the participants to identify that any change in road width had occurred.

  4. A Direct Measurement of the $W$ Decay Width

    Energy Technology Data Exchange (ETDEWEB)

    Vine, Troy [Univ. of College, London (United Kingdom)

    2008-08-01

    A direct measurement of the W boson total decay width is presented in proton-antiproton collisions at √s = 1.96 TeV using data collected by the CDF II detector. The measurement is made by fitting a simulated signal to the tail of the transverse mass distribution in the electron and muon decay channels. An integrated luminosity of 350 pb-1 is used, collected between February 2002 and August 2004. Combining the results from the separate decay channels gives the decay width as 2.038 ± 0.072 GeV in agreement with the theoretical prediction of 2.093 ± 0.002 GeV. A system is presented for the management of detector calibrations using a relational database schema. A description of the implementation and monitoring of a procedure to provide general users with a simple interface to the complete set of calibrations is also given.

  5. Temperature dependence of spreading width of giant dipole resonance

    International Nuclear Information System (INIS)

    Storozhenko, A.N.; Vdovin, A.I.; Ventura, A.; Blokhin, A.I.

    2002-01-01

    The Quasiparticle-Phonon Nuclear Model extended to finite temperature within the framework of Thermo Field Dynamics is applied to calculate a temperature dependence of the spreading width Γ ↓ of a giant dipole resonance. Numerical calculations are made for 120 Sn and 208 Pb nuclei. It is found that Γ ↓ increases with T. The reason of this effect is discussed as well as a relation of the present approach to other ones, existing in the literature

  6. Pole mass, width, and propagators of unstable fermions

    International Nuclear Information System (INIS)

    Kniehl, B.A.; Sirlin, A.

    2008-01-01

    The concepts of pole mass and width are extended to unstable fermions in the general framework of parity-nonconserving gauge theories, such as the Standard Model. In contrast with the conventional on-shell definitions, these concepts are gauge independent and avoid severe unphysical singularities, properties of great importance since most fundamental fermions in nature are unstable particles. General expressions for the unrenormalized and renormalized dressed propagators of unstable fermions and their field-renormalization constants are presented. (orig.)

  7. Porous Alumina Films with Width-Controllable Alumina Stripes

    Directory of Open Access Journals (Sweden)

    Huang Shi-Ming

    2010-01-01

    Full Text Available Abstract Porous alumina films had been fabricated by anodizing from aluminum films after an electropolishing procedure. Alumina stripes without pores can be distinguished on the surface of the porous alumina films. The width of the alumina stripes increases proportionally with the anodizing voltage. And the pores tend to be initiated close to the alumina stripes. These phenomena can be ascribed to the electric field distribution in the alumina barrier layer caused by the geometric structure of the aluminum surface.

  8. Porous Alumina Films with Width-Controllable Alumina Stripes

    Science.gov (United States)

    2010-01-01

    Porous alumina films had been fabricated by anodizing from aluminum films after an electropolishing procedure. Alumina stripes without pores can be distinguished on the surface of the porous alumina films. The width of the alumina stripes increases proportionally with the anodizing voltage. And the pores tend to be initiated close to the alumina stripes. These phenomena can be ascribed to the electric field distribution in the alumina barrier layer caused by the geometric structure of the aluminum surface. PMID:21170406

  9. Characterizing the width of amphibian movements during postbreeding migration.

    Science.gov (United States)

    Coster, Stephanie S; Veysey Powell, Jessica S; Babbitt, Kimberly J

    2014-06-01

    Habitat linkages can help maintain connectivity of animal populations in developed landscapes. However, the lack of empirical data on the width of lateral movements (i.e., the zigzagging of individuals as they move from one point to point another) makes determining the width of such linkages challenging. We used radiotracking data from wood frogs (Lithobates sylvaticus) and spotted salamanders (Ambystoma maculatum) in a managed forest in Maine (U.S.A.) to characterize movement patterns of populations and thus inform planning for the width of wildlife corridors. For each individual, we calculated the polar coordinates of all locations, estimated the vector sum of the polar coordinates, and measured the distance from each location to the vector sum. By fitting a Gaussian distribution over a histogram of these distances, we created a population-level probability density function and estimated the 50th and 95th percentiles to determine the width of lateral movement as individuals progressed from the pond to upland habitat. For spotted salamanders 50% of lateral movements were ≤13 m wide and 95% of movements were ≤39 m wide. For wood frogs, 50% of lateral movements were ≤17 m wide and 95% of movements were ≤ 51 m wide. For both species, those individuals that traveled the farthest from the pond also displayed the greatest lateral movement. Our results serve as a foundation for spatially explicit conservation planning for pond-breeding amphibians in areas undergoing development. Our technique can also be applied to movement data from other taxa to aid in designing habitat linkages. © 2014 Society for Conservation Biology.

  10. Conversion width of Σ-hyperon in nuclear matter

    International Nuclear Information System (INIS)

    Filimonov, V.A.

    1983-01-01

    Width G of ΣN→ΛN conversion for Σ - hyperon in nuclear matter on the base of one-boson exchange model is calculated. Essential compensation of contributions of diffe-- rent mesons to amplitude of the conversiop is shown to take place. As a result G decreases approximately twice as compaped with the value from exchange only by π-meson. Without accout of Pauli principle it is obtained G=15-25 MeV

  11. Technique for estimating relocated gap width for gap conductance calculations

    International Nuclear Information System (INIS)

    Klink, P.H.

    1978-01-01

    Thermally induced fuel fragmentation and relocation has been demonstrated to influence the thermal behavior of a fuel rod in two ways. The effective fuel pellet conductivity is decreased and pellet-to-cladding heat transfer is improved. This paper presents a correlation between as-built and relocated gap width which, used with the Ross and Stoute Gap Conductance Correlation and an appropriate fuel thermal expansion model, closely predicts the measured gap conductances

  12. Protein Structure-sensitive Analysis by Normal Pulse Voltammetry

    Czech Academy of Sciences Publication Activity Database

    Černocká, Hana; Paleček, Emil

    2016-01-01

    Roč. 28, č. 11 (2016), s. 2884-2889 ISSN 1040-0397 R&D Projects: GA ČR(CZ) GA15-15479S Institutional support: RVO:68081707 Keywords : mercury -electrodes * deoxyribonucleic-acid * hydrogen evolution Subject RIV: BO - Biophysics Impact factor: 2.851, year: 2016

  13. Stark widths regularities within spectral series of sodium isoelectronic sequence

    Science.gov (United States)

    Trklja, Nora; Tapalaga, Irinel; Dojčinović, Ivan P.; Purić, Jagoš

    2018-02-01

    Stark widths within spectral series of sodium isoelectronic sequence have been studied. This is a unique approach that includes both neutrals and ions. Two levels of problem are considered: if the required atomic parameters are known, Stark widths can be calculated by some of the known methods (in present paper modified semiempirical formula has been used), but if there is a lack of parameters, regularities enable determination of Stark broadening data. In the framework of regularity research, Stark broadening dependence on environmental conditions and certain atomic parameters has been investigated. The aim of this work is to give a simple model, with minimum of required parameters, which can be used for calculation of Stark broadening data for any chosen transitions within sodium like emitters. Obtained relations were used for predictions of Stark widths for transitions that have not been measured or calculated yet. This system enables fast data processing by using of proposed theoretical model and it provides quality control and verification of obtained results.

  14. Measurement of the mass and width of the W boson

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Anagnostou, G.; Anderson, K.J.; Asai, S.; Axen, D.; Bailey, I.; Barberio, E.; Barillari, T.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brown, Robert M.; Burckhart, H.J.; Campana, S.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, D.G.; Ciocca, C.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Gagnon, P.; Gary, John William; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harel, A.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herten, G.; Heuer, R.D.; Hill, J.C.; Horvath, D.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanzaki, J.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kramer, T.; Krasznahorkay, A.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Lellouch, D.; Letts, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, A.; Ludwig, J.; Mader, W.; Marcellini, S.; Martin, A.J.; Mashimo, T.; Mattig, Peter; McKenna, J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Meyer, Niels T.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rossi, A.M.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schorner-Sadenius, T.; Schroder, Matthias; Schumacher, M.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2006-01-01

    The mass and width of the W boson are measured using e+e- -> W+W- events from the data sample collected by the OPAL experiment at LEP at centre-of-mass energies between 170 GeV and 209 GeV. The mass (mw) and width (gw) are determined using direct reconstruction of the kinematics of W+W- -> qqbarlv and W+W- -> qqbarqqbar events. When combined with previous OPAL measurements using W+W- -> lvlv events and the dependence on mw of the WW production cross-section at threshold, the results are determined to be mw = 80.415 +- 0.042 +- 0.030 +- 0.009 GeV gw = 1.996 +- 0.096 +- 0.102 +- 0.003 GeV where the first error is statistical, the second systematic and the third due to uncertainties in the value of the LEP beam energy. By measuring mw with several different jet algorithms in the qqbarqqbar channel, a limit is also obtained on possible final-state interactions due to colour reconnection effects in W+W- -> qqbarqqbar events. The consistency of the results for the W mass and width with those inferred from other ele...

  15. Balance (perceived and actual) and preferred stance width during pregnancy.

    Science.gov (United States)

    Jang, John; Hsiao, Katherine T; Hsiao-Wecksler, Elizabeth T

    2008-05-01

    Pregnant women often remark that their balance degrades during pregnancy; however, it appears that no studies have documented the gravida's perception of her balance nor measured direction-specific changes in balance throughout pregnancy or after delivery. Thirty women, fifteen pregnant and fifteen non-pregnant controls, were tested monthly and through 6-month postpartum. For each session, perceived degradation in sense of balance, laboratory-based balance measures, stance width, and the number of falls since the previous session were recorded. Laboratory-based balance measures, quantified by direction-specific measures of postural sway, were computed from ten 30s quiet-standing trials on a stationary force platform. Repeated-measures analysis of variance, paired t-tests, and Pearson correlations were use to examine group and time effects. For the pregnant group, perceived balance degradation and stance width were highly correlated (r = 0.94). Both increased during pregnancy (P r > 0.72) and also decreased significantly between the third trimester and postpartum (P pregnancy, but increased after delivery. Contrary to recent work suggesting fall rates of 25%, only 13% of our subjects (n = 2) fell during pregnancy. Perceived degradation in balance during pregnancy was strongly related to increasing postural sway instability in the anterior-posterior direction. Lateral stability was maintained during pregnancy and likely accomplished by increasing stance width.

  16. Predictors of the peak width for networks with exponential links

    Science.gov (United States)

    Troutman, B.M.; Karlinger, M.R.

    1989-01-01

    We investigate optimal predictors of the peak (S) and distance to peak (T) of the width function of drainage networks under the assumption that the networks are topologically random with independent and exponentially distributed link lengths. Analytical results are derived using the fact that, under these assumptions, the width function is a homogeneous Markov birth-death process. In particular, exact expressions are derived for the asymptotic conditional expectations of S and T given network magnitude N and given mainstream length H. In addition, a simulation study is performed to examine various predictors of S and T, including N, H, and basin morphometric properties; non-asymptotic conditional expectations and variances are estimated. The best single predictor of S is N, of T is H, and of the scaled peak (S divided by the area under the width function) is H. Finally, expressions tested on a set of drainage basins from the state of Wyoming perform reasonably well in predicting S and T despite probable violations of the original assumptions. ?? 1989 Springer-Verlag.

  17. Ridge Width Correlations between Inked Prints and Powdered Latent Fingerprints.

    Science.gov (United States)

    De Alcaraz-Fossoul, Josep; Barrot-Feixat, Carme; Zapico, Sara C; Mancenido, Michelle; Broatch, Jennifer; Roberts, Katherine A; Carreras-Marin, Clara; Tasker, Jack

    2017-10-03

    A methodology to estimate the time of latent fingerprint deposition would be of great value to law enforcement and courts. It has been observed that ridge topography changes as latent prints age, including the widths of ridges that could be measured as a function of time. Crime suspects are commonly identified using fingerprint databases that contain reference inked tenprints (flat and rolled impressions). These can be of interest in aging studies as they provide baseline information relating to the original (nonaged) ridges' widths. In practice, the age of latent fingerprints could be estimated following a comparison process between the evidentiary aged print and the corresponding reference inked print. The present article explores possible correlations between inked and fresh latent fingerprints deposited on different substrates and visualized with TiO 2 . The results indicate that the ridge width of flat inked prints is most similar to fresh latent fingerprints , and these should be used as the comparison standard for future aging studies. © 2017 American Academy of Forensic Sciences.

  18. A simple sub-nanosecond ultraviolet light pulse generator with high repetition rate and peak power.

    Science.gov (United States)

    Binh, P H; Trong, V D; Renucci, P; Marie, X

    2013-08-01

    We present a simple ultraviolet sub-nanosecond pulse generator using commercial ultraviolet light-emitting diodes with peak emission wavelengths of 290 nm, 318 nm, 338 nm, and 405 nm. The generator is based on step recovery diode, short-circuited transmission line, and current-shaping circuit. The narrowest pulses achieved have 630 ps full width at half maximum at repetition rate of 80 MHz. Optical pulse power in the range of several hundreds of microwatts depends on the applied bias voltage. The bias voltage dependences of the output optical pulse width and peak power are analysed and discussed. Compared to commercial UV sub-nanosecond generators, the proposed generator can produce much higher pulse repetition rate and peak power.

  19. Water-dielectric-breakdown relation for the design of large-area multimegavolt pulsed-power systems

    Directory of Open Access Journals (Sweden)

    W. A. Stygar

    2006-07-01

    Full Text Available We have developed an empirical electrical-breakdown relation that can be used to design large-area water-insulated pulsed-power systems. Such systems often form an integral part of multiterawatt pulsed-power accelerators, and may be incorporated in future petawatt-class machines. We find that complete dielectric failure is likely to occur in water between a significantly field-enhanced anode and a less-enhanced cathode when E_{p}τ_{eff}^{0.330±0.026}=0.135±0.009. In this expression E_{p}≡V_{p}/d is the peak value in time of the spatially averaged electric field between the anode and cathode (in MV/cm, V_{p} is the peak voltage across the electrodes, d is the distance between the anode and cathode, and τ_{eff} is the temporal width (in μs of the voltage pulse at 63% of peak. This relation is based on 25 measurements for which 1≤V_{p}≤4.10   MV, 1.25≤d≤22   cm, and 0.011≤τ_{eff}≤0.6   μs. The normalized standard deviation of the differences between these measurements and the associated predictions of the relation is 12%.

  20. Seven harmonic susceptibility in oxygen and hydrogen loading of sintered YBCO by μs pulsed electrolysis in an aqueous solution at room temperature

    International Nuclear Information System (INIS)

    Tripodi, P.; Di Gioacchino, D.; Celani, F.

    1996-09-01

    The complex AC susceptibility of high T c superconducting materials has been described in terms of the first seven harmonic component of Fourier series. Has been measured the χ' n and χ n (n=1,7) of sintered YBa 2 Cu 3 O 7-x (YBCO) bulk oxygen and hydrogen loaded samples versus amplitude and frequency of AC magnetic field at fixed temperature. The sample have been loaded by μs current pulses electrolysis in an aqueous solution (0.3N LiOH+H 2 O) at room temperature. In addition to the simplicity of the experimental setup, this procedure allows to obtain extremely high equivalent hydrogen/oxygen gas pressure on the surface of the electrodes. The YBCO electrode is polarized by short pulse width (0.5-10 μs) and high power (120 W) peaks with a variable repetition rate (0.1-10000 Hz). The pulses are obtained by an home.made pulse generator. The difference in the behavior of the susceptibilities harmonic component between the deficiency and oxygen or hydrogen loaded samples give us the possibility to connect the susceptibilities with variations of the flux pinning in respect to normal losses in the superconducting materials. The loading can be a good probe to have information on the mechanism of the processes that sustain the critical current density Jc in this situation these affects appear strongly dependent on the loading conditions. By comparison of this measurements has been observed drastic change in behavior of susceptibility

  1. Normal Pressure Hydrocephalus (NPH)

    Science.gov (United States)

    ... local chapter Join our online community Normal Pressure Hydrocephalus (NPH) Normal pressure hydrocephalus is a brain disorder ... Symptoms Diagnosis Causes & risks Treatments About Normal Pressure Hydrocephalus Normal pressure hydrocephalus occurs when excess cerebrospinal fluid ...

  2. Investigation of Pitch and Jaw Width to Decrease Delivery Time of Helical Tomotherapy Treatments for Head and Neck Cancer

    International Nuclear Information System (INIS)

    Moldovan, Monica; Fontenot, Jonas D.; Gibbons, John P.; Lee, Tae Kyu; Rosen, Isaac I.; Fields, Robert S.; Hogstrom, Kenneth R.

    2011-01-01

    Helical tomotherapy plans using a combination of pitch and jaw width settings were developed for 3 patients previously treated for head and neck cancer. Three jaw widths (5, 2.5, and 1 cm) and 4 pitches (0.86, 0.43, 0.287, and 0.215) were used with a (maximum) modulation factor setting of 4. Twelve plans were generated for each patient using an identical optimization procedure (e.g., number of iterations, objective weights, and penalties, etc.), based on recommendations from TomoTherapy (Madison, WI). The plans were compared using isodose plots, dose volume histograms, dose homogeneity indexes, conformity indexes, radiobiological models, and treatment times. Smaller pitches and jaw widths showed better target dose homogeneity and sparing of normal tissue, as expected. However, the treatment time increased inversely proportional to the jaw width, resulting in delivery times of 24 ± 1.9 min for the 1-cm jaw width. Although treatment plans produced with the 2.5-cm jaw were dosimetrically superior to plans produced with the 5-cm jaw, subsequent calculations of tumor control probabilities and normal tissue complication probabilities suggest that these differences may not be radiobiologically meaningful. Because treatment plans produced with the 5-cm jaw can be delivered in approximately half the time of plans produced with the 2.5-cm jaw (5.1 ± 0.6 min vs. 9.5 ± 1.1 min), use of the 5-cm jaw in routine treatment planning may be a viable approach to decreasing treatment delivery times from helical tomotherapy units.

  3. A hybrid pulse combining topology utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer.

    Science.gov (United States)

    Li, Jiangtao; Zhao, Zheng; Sun, Yi; Liu, Yuhao; Ren, Ziyuan; He, Jiaxin; Cao, Hui; Zheng, Minjun

    2017-03-01

    Numerous applications driven by pulsed voltage require pulses to be with high amplitude, high repetitive frequency, and narrow width, which could be satisfied by utilizing avalanche transistors. The output improvement is severely limited by power capacities of transistors. Pulse combining is an effective approach to increase the output amplitude while still adopting conventional pulse generating modules. However, there are drawbacks in traditional topologies including the saturation tendency of combining efficiency and waveform oscillation. In this paper, a hybrid pulse combining topology was adopted utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer. The factors affecting the combining efficiency were determined including the output time synchronization of Marx circuits, and the quantity and position of magnetic cores. The numbers of the parallel modules and the stages were determined by the output characteristics of each combining method. Experimental results illustrated the ability of generating pulses with 2-14 kV amplitude, 7-11 ns width, and a maximum 10 kHz repetitive rate on a matched 50-300 Ω resistive load. The hybrid topology would be a convinced pulse combining method for similar nanosecond pulse generators based on the solid-state switches.

  4. Pulse generator circuit triggerable by nuclear radiation

    International Nuclear Information System (INIS)

    Fredrickson, P.B.

    1980-01-01

    A pulse generator circuit triggerable by a pulse of nuclear radiation is described. The pulse generator circuit includes a pair of transistors arranged, together with other electrical components, in the topology of a standard monostable multivibrator circuit. The circuit differs most significantly from a standard monostable multivibrator circuit in that the circuit is adapted to be triggered by a pulse of nuclear radiation rather than electrically and the transistors have substantially different sensitivities to radiation, due to different physical and electrical characteristics and parameters. One of the transistors is employed principally as a radiation detector and is in a normally non-conducting state and the other transistor is normally in a conducting state. When the circuit is exposed to a pulse of nuclear radiation, currents are induced in the collector-base junctions of both transistors but, due to the different radiation sensitivities of the transistors, the current induced in the collector-base junction of the radiation-detecting transistor is substantially greater than that induced in the collector-base junction of the other transistor. The pulse of radiation causes the radiation-detecting transistor to operate in its conducting state, causing the other transistor to operate in its non-conducting state. As the radiation-detecting transistor operates in its conducting state, an output signal is produced at an output terminal connected to the radiation-detecting transistor indicating the presence of a predetermined intensity of nuclear radiation

  5. Computer control of pulsed tunable dye lasers

    International Nuclear Information System (INIS)

    Thattey, S.S.; Dongare, A.S.; Suri, B.M.; Nair, L.G.

    1992-01-01

    Pulsed tunable dye lasers are being used extensively for spectroscopic and photo-chemical experiments, and a system for acquisition and spectral analysis of a volume of data generated will be quite useful. The development of a system for wavelength tuning and control of tunable dye lasers and an acquisition system for spectral data generated in experiments with these lasers are described. With this system, it is possible to control the tuning of three lasers, and acquire data in four channels, simultaneously. It is possible to arrive at the desired dye laser wavelength with a reproducibility of ± 0.012 cm -1 , which is within the absorption width (atomic interaction) caused by pulsed dye lasers of linewidth 0.08 cm -1 . The spectroscopic data generated can be analyzed for spectral identification within absolute accuracy ± 0.012 cm -1 . (author). 6 refs., 11 figs

  6. Method for detecting and distinguishing between specific types of environmental radiation using a high pressure ionization chamber with pulse-mode readout

    Science.gov (United States)

    Degtiarenko, Pavel V.

    2017-12-19

    An environmental radiation detector for detecting and distinguishing between all types of environmental radiation, including photons, charged particles, and neutrons. A large volume high pressure ionization chamber (HPIC) includes BF.sub.3 gas at a specific concentration to render the radiation detector sensitive to the reactions of neutron capture in Boron-10 isotope. A pulse-mode readout is connected to the ionization chamber capable of measuring both the height and the width of the pulse. The heavy charged products of the neutron capture reaction deposit significant characteristic energy of the reaction in the immediate vicinity of the reaction in the gas, producing a signal with a pulse height proportional to the reaction energy, and a narrow pulse width corresponding to the essentially pointlike energy deposition in the gas. Readout of the pulse height and the pulse width parameters of the signals enables distinguishing between the different types of environmental radiation, such as gamma (x-rays), cosmic muons, and neutrons.

  7. Analysis Of The Effect Of Flow Channel Width On The Performance Of PEMFC

    Directory of Open Access Journals (Sweden)

    Elif Eker

    2013-08-01

    Full Text Available In this work, it was analysed the effect of different channel width on performance of PEM fuel cell. Current density were measured on the single cells of parallel flow fields that has 25 cm² active layer, using three different kinds of channel width. The cell width and the channel height remain constant.The results show that increasing the channel width while the cell width remains constant decreases the current density.

  8. Generation of femtosecond electron single pulse using laser photocathode RF gun

    Energy Technology Data Exchange (ETDEWEB)

    Uesaka, M.; Kinoshita, K.; Watanabe, T. [Nuclear Engineering Research Laboratory, University of Tokyo, Tokai, Ibaraki (JP)] [and others

    1998-11-01

    A new laser photocathode RF electron gun was installed in the second linac of the S-band twin linac system of Nuclear Engineering Research Laboratory(NERL) of University of Tokyo in August in 1997. Since then, the behavior of the new gun has been tested and the characteristic parameters have been evaluated. At the exit of the gun, the energy is 4.7 MeV, the charge per bunch 1 nC, the pulse width is 10 ps(FWHM), respectively, for 6 MW RF power supply from a klystron. The electron bunch is accelerated up to 17 MeV. The horizontal normalized emittance is 1 {pi} mm.mrad. Then, the bunch is compressed to be 440 fs(FWHM) with 0.35 nC by the chicane-type magnetic pulse compressor. The gun is planned to be used for femtosecond X-ray generation via the head-on Thomson scattering and laser wakefield acceleration in 1998. (author)

  9. Passivation of black phosphorus saturable absorbers for reliable pulse formation of fiber lasers.

    Science.gov (United States)

    Na, Dongsoo; Park, Kichul; Park, Ki-Hwan; Song, Yong-Won

    2017-11-24

    Black phosphorus (BP) has attracted increasing attention due to its unique electrical properties. In addition, the outstanding optical nonlinearity of BP has been demonstrated in various ways. Its functionality as a saturable absorber, in particular, has been validated in demonstrations of passive mode-locked lasers. However, normally, the performance of BP is degraded eventually by both thermal and chemical damage in ambient conditions. The passivation of BP is the critical issue to guarantee a stable performance of the optical devices. We quantitatively characterized the mode-locked lasers operated by BP saturable absorbers with diversified passivation materials such as polydimethylsiloxane (PDMS) or Al 2 O 3 , considering the atomic structure of the materials, and therefore the hydro-permeability of the passivation layers. Unlike the BP layers without passivation, we demonstrated that the Al 2 O 3 -passivated BP layer was protected from the surface oxidation reaction in the long-term, and the PDMS-passivated one had a short-term blocking effect. The quantitative analysis showed that the time-dependent characteristics of the pulsed laser without passivation were changed with respect to the pulse duration, spectral width, and time-bandwidth product displaying 550 fs, 2.8 nm, and 0.406, respectively. With passivation, the changes were limited to <43 fs, <0.3 nm, and <0.012, respectively.

  10. Passivation of black phosphorus saturable absorbers for reliable pulse formation of fiber lasers

    Science.gov (United States)

    Na, Dongsoo; Park, Kichul; Park, Ki-Hwan; Song, Yong-Won

    2017-11-01

    Black phosphorus (BP) has attracted increasing attention due to its unique electrical properties. In addition, the outstanding optical nonlinearity of BP has been demonstrated in various ways. Its functionality as a saturable absorber, in particular, has been validated in demonstrations of passive mode-locked lasers. However, normally, the performance of BP is degraded eventually by both thermal and chemical damage in ambient conditions. The passivation of BP is the critical issue to guarantee a stable performance of the optical devices. We quantitatively characterized the mode-locked lasers operated by BP saturable absorbers with diversified passivation materials such as polydimethylsiloxane (PDMS) or Al2O3, considering the atomic structure of the materials, and therefore the hydro-permeability of the passivation layers. Unlike the BP layers without passivation, we demonstrated that the Al2O3-passivated BP layer was protected from the surface oxidation reaction in the long-term, and the PDMS-passivated one had a short-term blocking effect. The quantitative analysis showed that the time-dependent characteristics of the pulsed laser without passivation were changed with respect to the pulse duration, spectral width, and time-bandwidth product displaying 550 fs, 2.8 nm, and 0.406, respectively. With passivation, the changes were limited to <43 fs, <0.3 nm, and <0.012, respectively.

  11. Spin gymnastics with selective radiofrequency pulses

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, R.; Kupce, E. [Cambridge Univ. (United Kingdom)

    1994-12-31

    Although high resolution NMR spectra are normally excited with short intense radiofrequency pulses, there is an entire family of new experiments that can be performed with frequency-selective or ``soft`` pulses. Time-consuming two-dimensional spectroscopy may be reduced to a much shorter one-dimensional version with much finer digitization in the frequency domain. A large number of soft pulses can be combined to form a ``polychromatic pulse`` that has uniform excitation over the entire range of proton shifts except for a rejection notch at the water frequency. Polychromatic pulses can also be used to create antiphase magnetization in preparation for a coherence transfer or double-quantum experiment. An excitation profile can be designed in the form of a ``template`` that exactly matches the spectrum of a given chemical compound but has zero excitation elsewhere. This is achieved by using the information in the experimental free induction decay to construct a suitable array of soft pulses that has the required excitation pattern. In this manner, interpenetrating spectra can be separated into the spectra of the pure components, for example those of a and b glucose. Selective Hartmann-Hahn coherence transfer experiments employ similar soft pulse techniques. If several such transfers are concatenated, the method may be used as a test to see whether a group of protons is linked in an unbroken chain by scalar spin-spin interactions. (authors). 24 refs., 18 figs.

  12. Kinetic studies on a repetitively pulsed fast reactor

    International Nuclear Information System (INIS)

    Das, S.

    1982-01-01

    Neutronic analysis of an earlier proposed periodically pulsed fast reactor at Kalpakkam (KPFR) has been carried out numerically under equilibrium and transient conditions using the one-point model of reactor kinetics and the experimentally measured total worth of reactivity modulator, the parabolic coefficient of reactivity of the movable reflector and the mean prompt neutron lifetime. Results of steady-state calculations - treated on the basis of delayed neutron precursor and energy balances during a period of operation - have been compared with the analytical formulae of Larrimore for a parabolic reactivity input. Empirical relations for half-width of the fast neutron pulse, the peak pulse power and the power at first crossing of prompt criticality have been obtained and shown to be accurate enough for predicting steady-state power pulse characteristics of a periodically pulsed fast reactor. The concept of a subprompt-critical reactor has been used to calculate the fictitious delayed neutron fraction, β of the KPFR through a numerical experiment. Relative pulse height stability and pulse shape sensitivity to changes of maximum reactivity is discussed. With the aid of new safety concepts, the Power Amplification Factor (PAF) and the Pulse Growth Factor (Rsub(p)), the dynamics KPFR under accidental conditions has been studied for step and ramp reactivity perturbations. All the analysis has been done without taking account of reactivity feedback. (orig.)

  13. An evaluation on environment radiation impact of pulsed reactor

    International Nuclear Information System (INIS)

    Gao Yingwei; Pu Gongxu; Li Jian

    1991-01-01

    The dose regulation, assessment scope and assessment method adopted by the environment impact evaluation for the pulsed reactor are discussed. The compute model, the compute programme and the compute result of the dose adopted for the model pulsed reactor are introduced. The probable environment radiation impact under normal status and accident status are also appraised

  14. Design Study for Pulsed Proton Beam Generation

    Directory of Open Access Journals (Sweden)

    Han-Sung Kim

    2016-02-01

    Full Text Available Fast neutrons with a broad energy spectrum, with which it is possible to evaluate nuclear data for various research fields such as medical applications and the development of fusion reactors, can be generated by irradiating proton beams on target materials such as beryllium. To generate short-pulse proton beam, we adopted a deflector and slit system. In a simple deflector with slit system, most of the proton beam is blocked by the slit, especially when the beam pulse width is short. Therefore, the available beam current is very low, which results in low neutron flux. In this study, we proposed beam modulation using a buncher cavity to increase the available beam current. The ideal field pattern for the buncher cavity is sawtooth. To make the field pattern similar to a sawtooth waveform, a multiharmonic buncher was adopted. The design process for the multiharmonic buncher includes a beam dynamics calculation and three-dimensional electromagnetic simulation. In addition to the system design for pulsed proton generation, a test bench with a microwave ion source is under preparation to test the performance of the system. The design study results concerning the pulsed proton beam generation and the test bench preparation with some preliminary test results are presented in this paper.

  15. BANSHEE: High-voltage repetitively pulsed electron-beam driver

    International Nuclear Information System (INIS)

    VanHaaften, F.

    1992-01-01

    BANSHEE (Beam Accelerator for a New Source of High-Energy Electrons) this is a high-voltage modulator is used to produce a high-current relativistic electron beam for high-power microwave tube development. The goal of the BANSHEE research is first to achieve a voltage pulse of 700--750 kV with a 1-μs pulse width driving a load of ∼100 Ω, the pulse repetition frequency (PRF) of a few hertz. The ensuing goal is to increase the pulse amplitude to a level approaching 1 MV. We conducted tests using half the modulator with an output load of 200 Ω, up to a level of ∼650 kV at a PRF of 1 Hz and 525 kV at a PRF of 5 Hz. We then conducted additional testing using the complete system driving a load of ∼100 Ω

  16. Nonlinear laser pulse response in a crystalline lens.

    Science.gov (United States)

    Sharma, R P; Gupta, Pradeep Kumar; Singh, Ram Kishor; Strickland, D

    2016-04-01

    The propagation characteristics of a spatial Gaussian laser pulse have been studied inside a gradient-index structured crystalline lens with constant-density plasma generated by the laser-tissue interaction. The propagation of the laser pulse is affected by the nonlinearities introduced by the generated plasma inside the crystalline lens. Owing to the movement of plasma species from a higher- to a lower-temperature region, an increase in the refractive index occurs that causes the focusing of the laser pulse. In this study, extended paraxial approximation has been applied to take into account the evolution of the radial profile of the Gaussian laser pulse. To examine the propagation characteristics, variation of the beam width parameter has been observed as a function of the laser power and initial beam radius. The cavitation bubble formation, which plays an important role in the restoration of the elasticity of the crystalline lens, has been investigated.

  17. Ultrashort pulse chirp measurement via transverse second-harmonic generation in strontium barium niobate crystal

    Energy Technology Data Exchange (ETDEWEB)

    Trull, J.; Wang, B.; Parra, A.; Vilaseca, R.; Cojocaru, C. [Departament de Física i Enginyeria Nuclear, Universitat Politècnica Catalunya, Terrassa 08222 (Spain); Sola, I. [Grupo de Investigación en Óptica Extrema (GIOE), Departamento de Física Aplicada, Universidad de Salamanca, Plaza de la Merced s/n, 37008 Salamanca (Spain); Krolikowski, W. [Laser Physics Centre, Research School of Physics and Engineering, Australian National University, Canberra ACT 0200 (Australia); Science Program, Texas A and M University at Qatar, Doha (Qatar); Sheng, Y. [Laser Physics Centre, Research School of Physics and Engineering, Australian National University, Canberra ACT 0200 (Australia)

    2015-06-01

    Pulse compression in dispersive strontium barium niobate crystal with a random size and distribution of the anti-parallel orientated nonlinear domains is observed via transverse second harmonic generation. The dependence of the transverse width of the second harmonic trace along the propagation direction allows for the determination of the initial chirp and duration of pulses in the femtosecond regime. This technique permits a real-time analysis of the pulse evolution and facilitates fast in-situ correction of pulse chirp acquired in the propagation through an optical system.

  18. Ultrashort pulse chirp measurement via transverse second-harmonic generation in strontium barium niobate crystal

    International Nuclear Information System (INIS)

    Trull, J.; Wang, B.; Parra, A.; Vilaseca, R.; Cojocaru, C.; Sola, I.; Krolikowski, W.; Sheng, Y.

    2015-01-01

    Pulse compression in dispersive strontium barium niobate crystal with a random size and distribution of the anti-parallel orientated nonlinear domains is observed via transverse second harmonic generation. The dependence of the transverse width of the second harmonic trace along the propagation direction allows for the determination of the initial chirp and duration of pulses in the femtosecond regime. This technique permits a real-time analysis of the pulse evolution and facilitates fast in-situ correction of pulse chirp acquired in the propagation through an optical system

  19. Normalization: A Preprocessing Stage

    OpenAIRE

    Patro, S. Gopal Krishna; Sahu, Kishore Kumar

    2015-01-01

    As we know that the normalization is a pre-processing stage of any type problem statement. Especially normalization takes important role in the field of soft computing, cloud computing etc. for manipulation of data like scale down or scale up the range of data before it becomes used for further stage. There are so many normalization techniques are there namely Min-Max normalization, Z-score normalization and Decimal scaling normalization. So by referring these normalization techniques we are ...

  20. Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose

    International Nuclear Information System (INIS)

    Serduc, Raphael; Fonta, Caroline; Renaud, Luc; Bouchet, Audrey; Braeuer-Krisch, Elke; Sarun, Sukhena; Bravin, Alberto; Le Duc, Geraldine; Laissue, Jean A; Spiga, Jenny; Boutonnat, Jean; Siegbahn, Erik Albert; Esteve, Francois

    2009-01-01

    To analyze the effects of the microbeam width (25, 50 and 75 μm) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 μm wide microbeams, all spaced 211 μm on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 μm wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of ∼50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 μm width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 μm or 25 μm widths when used with a 211 μm on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in all groups. The use